{"id":10055,"date":"2026-08-08T12:37:04","date_gmt":"2026-08-08T04:37:04","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=10055"},"modified":"2026-11-11T21:56:44","modified_gmt":"2026-11-11T13:56:44","slug":"%e6%88%90%e9%83%bd%e5%b8%82%e5%8f%8c%e6%b5%81%e5%8c%ba%e9%ba%93%e6%b9%96%e7%94%9f%e6%80%81%e5%9f%8e%e6%b2%84%e5%b2%b8%e8%94%a1%e8%80%81%e5%b8%88%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab160%e4%b8%ad","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=10055","title":{"rendered":"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8521\u8001\u5e08\u65e5\u7acb\u8212\u4eab160\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b"},"content":{"rendered":"\n\n<style>\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{scroll-behavior:smooth}\nbody{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",\"PingFang SC\",\"Microsoft YaHei\",\"Helvetica Neue\",sans-serif;background:#f5f5f7;color:#333;line-height:1.6;overflow-x:hidden}\n:root{--deep-blue:#1a3a6e;--gold:#c5a55a;--white:#fff;--bg-gray:#f5f5f7;--text-dark:#222;--text-gray:#666;--toc-height:52px}\n\/* ===== \u82f1\u96c4\u680f\u80cc\u666f ===== *\/\n.hero{position:relative;aspect-ratio:3\/1;max-height:420px;min-height:260px;display:flex;align-items:center;justify-content:center;background-color:#1a3a6e;background-image:url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-05.png'),linear-gradient(135deg,#1a3a6e 0%,#234a85 50%,#1a3a6e 100%);background-size:cover;background-position:center;background-repeat:no-repeat;overflow:hidden;max-width:1352px;margin:0 auto 16px;border-radius:0}\n.hero::before{content:'';position:absolute;inset:0;z-index:1;background:linear-gradient(rgba(0,0,0,0.3),rgba(0,0,0,0.5))}\n.hero-inner{position:relative;z-index:2;display:flex;flex-direction:column;align-items:center;justify-content:center;text-align:center;padding:20px;width:100%;max-width:760px}\n.hero-tagline{font-size:0.85rem;color:rgba(255,255,255,0.8);letter-spacing:2px;margin-bottom:10px}\n.hero-title{font-size:clamp(1.3rem,3.8vw,2.1rem);font-weight:700;color:#fff;margin-bottom:8px;text-shadow:0 2px 12px rgba(0,0,0,0.4)}\n.hero-subtitle{font-size:clamp(0.85rem,2vw,1.1rem);color:rgba(255,255,255,0.92);margin-bottom:20px}\n.hero-info-card{display:flex;gap:18px;flex-wrap:wrap;justify-content:center;backdrop-filter:blur(12px);-webkit-backdrop-filter:blur(12px);background:rgba(255,255,255,0.18);border-radius:12px;padding:16px 24px;border:1px solid rgba(255,255,255,0.25)}\n.hero-info-item{text-align:center;min-width:90px}\n.hero-info-item .label{font-size:0.7rem;color:rgba(255,255,255,0.72);letter-spacing:1px;margin-bottom:3px}\n.hero-info-item .value{font-size:1.02rem;font-weight:700;color:#fff}\n\/* ===== TOC \u5bfc\u822a ===== *\/\n.toc-wrapper{position:sticky;top:0;z-index:100;background:#1a3a6e;box-shadow:0 2px 8px rgba(0,0,0,0.12);max-width:1400px;margin:0 auto}\n.toc{display:flex;justify-content:center;height:var(--toc-height);max-width:1400px;margin:0 auto}\n.toc-btn{flex:1;border:none;background:transparent;color:rgba(255,255,255,0.78);font-size:0.92rem;font-weight:500;cursor:pointer;padding:0 10px;white-space:nowrap;position:relative;transition:color .2s;letter-spacing:.5px}\n.toc-btn:hover{color:#fff}\n.toc-btn.active{color:#fff}\n.toc-btn.active::after{content:'';position:absolute;bottom:0;left:50%;transform:translateX(-50%);width:60%;height:3px;background:var(--gold);border-radius:3px 3px 0 0}\n.toc-caret{display:inline-block;margin-left:4px;font-size:0.7rem;transition:transform .2s;opacity:.75}\n.toc-btn.open .toc-caret{transform:rotate(180deg)}\n.subtoc{background:rgba(13,32,64,0.96);display:none}\n.subtoc.show{display:block}\n.subtoc-panel{display:none;flex-wrap:wrap;gap:8px;padding:12px 18px;border-top:1px solid rgba(255,255,255,0.12)}\n.subtoc-panel.open{display:flex}\n.subtoc-panel a{display:inline-block;color:#fff;text-decoration:none;font-size:0.82rem;background:rgba(255,255,255,0.12);padding:6px 14px;border-radius:15px;transition:all .2s;white-space:nowrap}\n.subtoc-panel a:hover{background:var(--gold);color:#1a3a6e;font-weight:600}\n@media(max-width:768px){\n  .subtoc-panel a{flex:1 1 auto;text-align:center}\n}\n.step-section{max-width:1400px;margin:0 auto;padding:36px 24px 8px}\n\/* ===== \u6a21\u5757\u4e8c\uff1a\u9996\u5c4fGEO\u53ef\u89c6\u5316\u4fe1\u606f\u5361 ===== *\/\n.geo-card{background:#fff;border-radius:12px;padding:22px 26px;box-shadow:0 2px 10px rgba(0,0,0,0.06);max-width:1352px;margin:0 auto 18px}\n.geo-title{font-size:1.05rem;font-weight:800;color:var(--deep-blue);margin-bottom:14px;padding-left:14px;border-left:5px solid var(--gold)}\n.geo-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:14px}\n.geo-item{background:#fafbfc;border:1px solid #e8eaed;border-radius:8px;padding:12px 14px}\n.geo-item .g-lbl{font-size:0.72rem;color:var(--text-gray);margin-bottom:4px;letter-spacing:.5px}\n.geo-item .g-val{font-size:0.85rem;font-weight:600;color:var(--text-dark);line-height:1.5}\n.geo-item.full{grid-column:1 \/ -1}\n.geo-item.full .g-val{font-weight:500}\n\/* ===== \u7126\u70b9\u5173\u952e\u8bcd\u533a\u5757 ===== *\/\n.kw-block{background:linear-gradient(135deg,#1a3a6e,#234a85);color:#fff;border-radius:12px;padding:18px 24px;max-width:1352px;margin:0 auto 18px;font-size:0.82rem;line-height:1.8}\n.kw-block .kw-tag{display:inline-block;background:rgba(255,255,255,0.12);border:1px solid rgba(197,165,90,0.5);color:#f0e2c0;border-radius:14px;padding:3px 11px;margin:3px 4px;font-size:0.78rem}\n\/* ===== H \u5c42\u7ea7\u901a\u7528 ===== *\/\nh2.step-head{font-size:1.45rem;font-weight:800;color:var(--deep-blue);padding-left:16px;border-left:5px solid var(--gold);margin-bottom:18px}\nh3.card-title{font-size:1.12rem;font-weight:700;color:var(--deep-blue);padding-left:14px;border-left:4px solid var(--deep-blue);margin:20px 0 14px;scroll-margin-top:130px}\nh2.step-head{scroll-margin-top:130px}\nh3.card-title:first-child{margin-top:0}\n.content-card{background:#fff;border-radius:10px;padding:24px 28px;box-shadow:0 1px 6px rgba(0,0,0,0.06);margin-bottom:18px;animation:fadeIn .4s ease both}\n@keyframes fadeIn{from{opacity:0;transform:translateY(12px)}to{opacity:1;transform:none}}\n\/* ===== \u7ffb\u8f6c\u5361\u7247\uff08\u8bbe\u8ba1\u56fe \u2194 \u65b9\u6848\u914d\u7f6e\uff09 ===== *\/\n.flip-card{perspective:1200px;cursor:pointer;margin-bottom:18px}\n.flip-card-inner{position:relative;width:100%;min-height:520px;transition:transform .6s;transform-style:preserve-3d;border-radius:10px;box-shadow:0 2px 10px rgba(0,0,0,0.08);display:grid;grid-template-areas:\"stack\"}\n.flip-card.flipped .flip-card-inner{transform:rotateY(180deg)}\n.flip-front,.flip-back{grid-area:stack;position:relative;width:100%;height:auto;min-height:100%;backface-visibility:hidden;border-radius:10px;overflow:hidden;background:#fff}\n.flip-front{display:flex;flex-direction:column;justify-content:center;align-items:center;padding:24px}\n.flip-front img{max-width:100%;max-height:460px;object-fit:contain;border-radius:8px;border:1px solid #e8eaed}\n.flip-front .photo-cap{margin-top:10px;font-size:0.78rem;color:var(--text-gray);line-height:1.45;text-align:center;padding:0 2px}\n.flip-front .flip-hint{margin-top:14px;font-size:0.82rem;color:var(--gold);font-weight:600;display:flex;align-items:center;gap:6px}\n.flip-back{transform:rotateY(180deg);padding:24px 28px}\n.flip-back .card-title{margin-top:0}\n  \/* ===== S1 \u5ba2\u6237\u4fe1\u606f\u5361\u2194\u8212\u9002\u76ee\u6807 \u7ffb\u8f6c\u5361\u724c ===== *\/\n  #infoGoalFlip{cursor:pointer}\n  #infoGoalFlip .info-goal-front{display:block;text-align:left;padding:24px 28px}\n  #infoGoalFlip .info-goal-front .card-title{margin-top:0}\n  #infoGoalFlip .flip-back{display:flex;flex-direction:column;justify-content:center;gap:14px}\n  #infoGoalFlip .pacman-track{flex:1;min-height:230px;align-items:center;pointer-events:none}\n  #infoGoalFlip .pacman-detail{margin-top:2px}\n  .flip-hint{margin-top:8px;font-size:0.84rem;color:var(--gold);font-weight:600;text-align:center}\n.flip-icon{display:inline-block;width:18px;height:18px;border:2px solid currentColor;border-radius:50%;position:relative}\n.flip-icon::before{content:'';position:absolute;top:50%;left:50%;width:8px;height:8px;border-top:2px solid currentColor;border-right:2px solid currentColor;transform:translate(-50%,-35%) rotate(-45deg)}\n@media(max-width:768px){\n  .flip-card-inner{min-height:420px}\n  .flip-front img{max-height:300px}\n  .flip-back{padding:18px}\n  .flip-back .info-table{font-size:0.78rem}\n}\n.info-row{display:flex;gap:20px;flex-wrap:wrap;margin-bottom:10px}\n.info-cell{flex:1;min-width:120px}\n.info-cell .lbl{font-size:0.78rem;color:var(--text-gray);margin-bottom:2px}\n.info-cell .val{font-size:0.95rem;font-weight:600;color:var(--text-dark)}\n.info-block{margin-bottom:18px;padding-bottom:14px;border-bottom:1px dashed #e6e6ea}\n.info-block:last-child{border-bottom:none;margin-bottom:0;padding-bottom:0}\n.info-block-h{font-size:0.92rem;font-weight:700;color:var(--gold);margin-bottom:10px;letter-spacing:.5px}\n.quote{background:#fafbfc;border-left:3px solid var(--gold);padding:12px 16px;border-radius:0 8px 8px 0;font-style:italic;color:var(--text-dark);font-size:0.92rem}\n.quote-strong{background:linear-gradient(135deg,#fff8ec,#fdf3e0);border-left:4px solid var(--gold);padding:16px 20px;border-radius:0 10px 10px 0;font-size:1rem;font-weight:600;color:#7a5a18;margin:12px 0}\n.tag{display:inline-block;padding:4px 12px;border-radius:16px;font-size:0.82rem;margin:4px 6px 4px 0;background:rgba(26,58,110,0.08);color:var(--deep-blue);border:1px solid rgba(26,58,110,0.18)}\n.tag.gold{background:rgba(197,165,90,0.12);color:#a07830;border-color:rgba(197,165,90,0.35)}\n.info-table{width:100%;border-collapse:collapse;margin:12px 0;font-size:0.88rem}\n.info-table th{background:#f0f2f5;color:var(--deep-blue);padding:10px 12px;text-align:left;font-weight:600}\n.info-table td{padding:10px 12px;border-bottom:1px solid #eee}\n\/* ===== \u9010\u623f\u95f4\u51b7\u8d1f\u8377\u53ef\u89c6\u5316\u56fe\u8868 ===== *\/\n.load-summary{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:18px 0}\n.ls-card{background:linear-gradient(135deg,#f4f6f9,#fff);border:1px solid #e8eaed;border-radius:10px;padding:16px 8px;text-align:center;box-shadow:0 1px 4px rgba(0,0,0,0.04)}\n.ls-num{display:block;font-size:1.45rem;font-weight:800;color:var(--deep-blue);line-height:1}\n.ls-lbl{display:block;font-size:0.72rem;color:var(--text-gray);margin-top:4px}\n.room-chart{border:1px solid #e8eaed;border-radius:10px;overflow:hidden;background:#fff}\n.chart-header{display:grid;grid-template-columns:130px 140px 1fr 90px;gap:10px;align-items:center;background:#f0f2f5;padding:12px 16px;font-size:0.78rem;color:var(--text-gray);font-weight:600;border-bottom:1px solid #e8eaed}\n.room-row{display:grid;grid-template-columns:130px 140px 1fr 90px;gap:10px;align-items:center;padding:16px;border-bottom:1px solid #f0f2f5;transition:background .15s}\n.room-row:last-child{border-bottom:none}\n.room-row:hover{background:#fafbfc}\n.room-name{font-weight:700;color:var(--deep-blue);font-size:0.92rem}\n.room-area{display:inline-block;margin-top:4px;font-size:0.72rem;color:#fff;background:var(--gold);padding:2px 8px;border-radius:10px}\n.room-model{font-size:0.82rem;color:var(--text-dark);font-weight:500;line-height:1.4}\n.meter-track{position:relative;height:14px;background:#eef1f5;border-radius:7px;overflow:visible}\n.meter-design{position:absolute;top:-3px;bottom:-3px;width:2px;background:#9aa3af;z-index:2;border-radius:1px}\n.meter-design::after{content:'\u8bbe\u8ba1\u57fa\u51c6';position:absolute;top:-17px;left:50%;transform:translateX(-50%);font-size:0.62rem;color:#888;white-space:nowrap}\n.meter-actual{height:100%;border-radius:7px;background:linear-gradient(90deg,var(--deep-blue),#3aa0ff);position:relative;min-width:6px;transition:width .8s ease}\n.meter-actual::after{content:attr(data-val);position:absolute;right:6px;top:50%;transform:translateY(-50%);font-size:0.65rem;color:#fff;font-weight:700}\n.meter-labels{display:flex;justify-content:space-between;margin-top:5px;font-size:0.74rem}\n.meter-labels .actual{color:#c0392b;font-weight:700}\n.meter-labels .design{color:#888}\n.room-cap{text-align:right;font-weight:700;color:var(--deep-blue);font-size:0.95rem}\n.chart-note{margin-top:10px;font-size:0.8rem;color:var(--text-gray);line-height:1.5}\n@media(max-width:768px){\n  .load-summary{grid-template-columns:repeat(2,1fr)}\n  .chart-header{display:none}\n  .room-row{grid-template-columns:1fr;gap:8px;padding:16px}\n  .room-cap{text-align:left;font-size:0.9rem}\n}\n.step-card{background:#fafbfc;border-radius:6px;padding:16px;margin-bottom:10px;border:1px solid #eee;cursor:pointer}\n.step-card summary{font-weight:600;color:var(--deep-blue);cursor:pointer}\n.step-card summary::-webkit-details-marker{display:none}\n.step-card summary::before{content:'+ ';font-weight:700;margin-right:6px}\n.step-card[open] summary::before{content:'- '}\n.bold-spec{font-weight:700;color:var(--deep-blue)}\n.compare-table{width:100%;border-collapse:collapse;font-size:0.85rem;margin:12px 0}\n.compare-table th{background:var(--deep-blue);color:#fff;padding:10px 12px;text-align:center}\n.compare-table td{padding:10px 12px;text-align:center;border-bottom:1px solid #eee}\n.compare-table tr td:first-child{text-align:left;font-weight:600}\n.compare-table .highlight{background:rgba(197,165,90,0.1);color:var(--deep-blue);font-weight:600}\n.review-card{background:#fafbfc;border-left:3px solid var(--gold);padding:14px 18px;margin-bottom:12px;border-radius:0 8px 8px 0}\n.advantage-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px}\n.advantage-card{background:#fafbfc;border-radius:8px;padding:18px 20px;border:1px solid #e8e8ec;transition:box-shadow 0.2s}\n.advantage-card:hover{box-shadow:0 2px 10px rgba(0,0,0,0.06)}\n.advantage-card .adv-name{font-weight:700;color:var(--deep-blue);font-size:0.95rem;margin-bottom:6px}\n.advantage-card .adv-desc{font-size:0.85rem;color:var(--text-gray);line-height:1.5;margin-bottom:10px}\n.advantage-card .adv-expand{color:var(--deep-blue);font-size:0.8rem;cursor:pointer;border:none;background:none;padding:0;font-weight:500}\n.advantage-card .adv-expand:hover{color:var(--gold)}\n.advantage-card .adv-full{display:none;margin-top:10px;padding-top:10px;border-top:1px solid #e0e0e4;font-size:0.84rem;color:var(--text-dark);line-height:1.6}\n.advantage-card .adv-full.show{display:block}\n.timeline{display:flex;justify-content:space-between;align-items:flex-start;position:relative;padding:20px 0 10px;margin-bottom:16px}\n.timeline::before{content:'';position:absolute;top:34px;left:7%;right:7%;height:2px;background:var(--deep-blue);opacity:0.25}\n.timeline-step{display:flex;flex-direction:column;align-items:center;flex:1;cursor:pointer;position:relative;z-index:1}\n.timeline-dot{width:28px;height:28px;border-radius:50%;background:#fff;border:3px solid var(--deep-blue);display:flex;align-items:center;justify-content:center;font-size:0.75rem;font-weight:700;color:var(--deep-blue);transition:all 0.25s;margin-bottom:8px}\n.timeline-step.active .timeline-dot{background:var(--deep-blue);color:#fff}\n.timeline-label{font-size:0.78rem;font-weight:500;color:var(--text-dark);text-align:center;line-height:1.3}\n.timeline-step.active .timeline-label{color:var(--deep-blue);font-weight:700}\n.timeline-detail{margin-top:16px;padding:16px 20px;background:#fafbfc;border-radius:8px;border:1px solid #e8e8ec;font-size:0.88rem;line-height:1.6;display:none}\n.timeline-detail.show{display:block}\n.timeline-detail .step-num{font-weight:700;color:var(--deep-blue);margin-bottom:6px}\n.promise-grid{display:grid;grid-template-columns:1fr 1fr 1fr;gap:14px}\n.promise-card{background:#fafbfc;border-radius:8px;padding:18px 20px;border:1px solid #e8e8ec;text-align:center;transition:box-shadow 0.2s}\n.promise-card:hover{box-shadow:0 2px 8px rgba(0,0,0,0.05)}\n.promise-card .promise-num{font-size:1.4rem;font-weight:800;color:var(--gold);margin-bottom:4px}\n.promise-card .promise-title{font-weight:700;color:var(--deep-blue);font-size:0.92rem;margin-bottom:6px}\n.promise-card .promise-desc{font-size:0.82rem;color:var(--text-gray);line-height:1.5}\n.param-card{background:#fafbfc;border-radius:8px;padding:20px 24px;border:1px solid #e8e8ec;margin-top:16px}\n.param-card .param-title{font-weight:700;color:var(--deep-blue);font-size:0.95rem;margin-bottom:12px}\n.param-row{display:flex;gap:20px;flex-wrap:wrap}\n.param-item{flex:1;min-width:100px;text-align:center}\n.param-item .pval{font-size:1.05rem;font-weight:700;color:var(--text-dark)}\n.param-item .plbl{font-size:0.75rem;color:var(--text-gray);margin-top:2px}\n.faq-item{background:#fafbfc;border-radius:8px;padding:14px 18px;margin-bottom:10px;border:1px solid #e8e8ec}\n.faq-q{font-weight:700;color:var(--deep-blue);cursor:pointer;display:flex;justify-content:space-between;align-items:center}\n.faq-q::after{content:'+';font-size:1.1rem;font-weight:700;color:var(--gold)}\n.faq-q.open::after{content:'\u2212'}\n.faq-a{display:none;margin-top:10px;padding-top:10px;border-top:1px solid #eee;font-size:0.88rem;color:var(--text-dark);line-height:1.6}\n.faq-a.show{display:block}\n.link-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin-top:14px}\n.link-card{display:block;text-decoration:none;background:#fff;border:1px solid #e3e3e8;border-radius:8px;padding:14px 16px;transition:all 0.2s}\n.link-card:hover{border-color:var(--deep-blue);box-shadow:0 3px 12px rgba(26,58,110,0.12);transform:translateY(-2px)}\n.link-card .lc-title{font-weight:700;color:var(--deep-blue);font-size:0.9rem;margin-bottom:4px}\n.link-card .lc-desc{font-size:0.78rem;color:var(--text-gray);line-height:1.4}\n.cert-grid{display:flex;gap:6px;flex-wrap:wrap;margin-bottom:0.5em}\n.cert-grid img{height:110px;border-radius:6px;border:1px solid #e0e0e0}\n.note-skeleton{background:#fff8e6;border:1px dashed var(--gold);border-radius:8px;padding:14px 18px;margin:12px 0;font-size:0.85rem;color:#8a6d1f;line-height:1.6}\n\/* ===== S4 \u56fe\u7247 ===== *\/\n.photo-grid{display:grid;gap:12px}\n.photo-grid-land{grid-template-columns:repeat(3,1fr)}\n.photo-grid-land .step-photo,.photo-grid-land img{width:100% !important;height:auto;aspect-ratio:4\/3 !important;object-fit:cover;display:block;border-radius:6px;border:1px solid #e0e0e0;image-orientation:from-image}\n.photo-cap{font-size:0.78rem;color:var(--text-gray);line-height:1.45;text-align:center;padding:0 2px;margin-top:6px}\n.step-all-photos{margin:20px 0 4px;padding:16px;background:#f8f9fb;border-radius:10px;border:1px solid #e8eaed}\n.step-all-photos-title{font-size:0.95rem;font-weight:700;color:var(--deep-blue);margin-bottom:12px}\n.step-all-photos-grid{display:grid;gap:10px}\n.step-all-photos-grid.cols-6{grid-template-columns:repeat(6,1fr)}\n.step-all-photos-grid.photo-grid-land .step-photo-item img{width:100% !important;height:auto;aspect-ratio:4\/3 !important;object-fit:cover}\n.step-photo-item{display:flex;flex-direction:column;gap:6px}\n.step-photo-item img{width:100%;height:auto;aspect-ratio:auto;display:block;border-radius:8px;border:1px solid #e0e0e0;transition:transform .2s,box-shadow .2s;image-orientation:from-image}\n.step-photo-cap{font-size:0.78rem;color:var(--text-gray);line-height:1.45;text-align:center;padding:0 2px}\n.photo-card{display:flex;flex-direction:column;gap:6px}\n\/* ===== \u6a2a\u5411\u7167\u7247\u7f51\u683c\uff08\u65b0\u589e\uff09 ===== *\/\n.photo-grid-h{display:grid;gap:12px;margin:14px 0}\n.photo-grid-h.cols-2{grid-template-columns:repeat(2,1fr)}\n.photo-grid-h.cols-3{grid-template-columns:repeat(3,1fr)}\n.photo-grid-h.cols-4{grid-template-columns:repeat(4,1fr)}\n.photo-grid-h.cols-6{grid-template-columns:repeat(6,1fr)}\n.photo-grid-h .ph{margin:0;display:flex;flex-direction:column;gap:6px}\n.photo-grid-h .ph img{width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;border-radius:6px;border:1px solid #e0e0e0;display:block;transition:transform .2s,box-shadow .2s;image-orientation:from-image}\n.photo-grid-h .ph:hover img{transform:translateY(-2px);box-shadow:0 6px 16px rgba(0,0,0,.12)}\n\/* \u4fee\u590d lhstyya-cls- \u65bd\u5de5\u7167\u7247\u9006\u65f6\u948890\u5ea6\uff1aimg \u5916\u5305 4:3 \u5bb9\u5668\uff0c\u65cb\u8f6c+90\u5ea6\u540e\u586b\u6ee1 *\/\n.ph-img-wrap.rotate-fix{aspect-ratio:4\/3;overflow:hidden;position:relative;border-radius:6px;border:1px solid #e0e0e0;background:#f5f5f5}\n.ph-img-wrap.rotate-fix img{position:absolute;top:50%;left:50%;width:75%;height:133.333%;object-fit:cover;border:none !important;border-radius:0 !important;transform:translate(-50%,-50%) rotate(270deg);transition:transform .2s,box-shadow .2s}\n.ph-img-wrap.rotate-fix:hover img{transform:translate(-50%,-50%) rotate(270deg) scale(1.02);box-shadow:0 6px 16px rgba(0,0,0,.12)}\n.photo-grid-h .ph-cap{font-size:0.78rem;color:var(--text-gray);line-height:1.45;text-align:center;padding:0 2px}\n.gallery-group{margin:20px 0 6px}\n.gallery-group-title{font-size:0.92rem;font-weight:700;color:var(--deep-blue);margin:6px 0 2px;padding-left:10px;border-left:3px solid var(--gold)}\n\/* ===== \u95e8\u5e97\/\u6388\u6743\/CTA ===== *\/\n.auth-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin:8px 0}\n.auth-item img{width:100%;aspect-ratio:3\/4;object-fit:contain;border-radius:8px;border:1px solid #e0e0e0;background:#fff;display:block;transition:transform .2s,box-shadow .2s}\n.auth-cap{text-align:center;font-size:0.8rem;color:var(--text-gray);margin:8px 0 0;line-height:1.4}\n.store-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:18px}\n.store-item img{width:auto;max-width:100%;height:auto;border-radius:10px;display:block;margin:0 auto;transition:transform .2s,box-shadow .2s}\n.store-cap{text-align:center;font-size:0.85rem;font-weight:600;color:var(--deep-blue);margin:10px 0 0}\n.store-info{text-align:center;font-size:0.8rem;color:var(--text-gray);margin:6px 0 0;line-height:1.7}\n.store-cta-wrap{max-width:1400px;margin:40px auto 20px;padding:32px 28px 36px;background:#f7f8fb;border-radius:12px;text-align:center}\n.cta-header{text-align:center;margin-bottom:24px}\n.cta-title{font-size:1.5rem;font-weight:700;color:#333;margin-bottom:8px}\n.cta-subtitle{font-size:0.92rem;color:#666;letter-spacing:.5px}\n.phone-cards{display:flex;justify-content:center;gap:24px;margin:24px auto;flex-wrap:wrap}\n.phone-card{display:inline-flex;align-items:center;gap:8px;padding:12px 24px;background:#fff;border:2px solid #e8ecf1;border-radius:50px;font-size:0.95rem;color:#333;text-decoration:none;transition:border-color .2s,color .2s}\n.phone-card:hover{border-color:var(--deep-blue);color:var(--deep-blue)}\n.pc-icon{font-size:1.05rem}\n.pc-num{font-weight:700;color:var(--deep-blue)}\n.store-badge{text-align:center;font-size:0.95rem;font-weight:700;color:var(--deep-blue);margin-bottom:10px}\n.store-addr{text-align:center;font-size:0.82rem;color:var(--text-gray);margin-top:10px;line-height:1.6}\n.local-serve{display:flex;flex-wrap:wrap;gap:10px;justify-content:center;margin:18px 0}\n.local-serve .ls-item{background:#fff;border:1px solid #e8ecf1;border-radius:8px;padding:10px 16px;font-size:0.84rem;color:var(--text-dark)}\n.action-row{display:flex;align-items:center;justify-content:center;gap:28px;margin-top:28px;flex-wrap:wrap}\n.btn-cta{display:inline-flex;align-items:center;padding:14px 36px;background:#e74c3c;color:#fff;font-size:1.02rem;font-weight:700;border-radius:50px;text-decoration:none;transition:background .2s,transform .15s}\n.btn-cta:hover{background:#c0392b;transform:translateY(-1px)}\n.service-info{font-size:0.9rem;color:var(--text-gray)}\n.disclaimer-note{margin-top:16px;font-size:0.78rem;color:#aaa;text-align:center}\n.privacy-statement{max-width:1400px;margin:0 auto;padding:24px 24px 36px;background:#f4f6f9;border-top:3px solid var(--gold)}\n.privacy-title{text-align:center;font-size:1.05rem;font-weight:700;color:var(--deep-blue);letter-spacing:2px}\n.privacy-sub{text-align:center;font-size:0.8rem;color:var(--gold);margin:4px 0 14px;letter-spacing:1px}\n.privacy-list{list-style:none;margin:0;padding:0;max-width:680px;margin:0 auto}\n.privacy-list li{position:relative;padding:6px 0 6px 18px;font-size:0.84rem;color:var(--text-gray);line-height:1.7;border-bottom:1px dashed #e2e5ea}\n.privacy-list li:last-child{border-bottom:none}\n.privacy-list li::before{content:\"\";position:absolute;left:0;top:14px;width:6px;height:6px;border-radius:50%;background:var(--gold)}\n.section-tabs{display:flex;gap:6px;flex-wrap:wrap;margin-bottom:16px;padding:8px 0;border-bottom:2px solid #e8e8ec}\n.section-tab{font-size:0.82rem;padding:6px 14px;border-radius:6px;cursor:pointer;color:var(--text-gray);background:#f0f2f5;transition:all .2s;white-space:nowrap;user-select:none}\n.section-tab:hover{color:var(--deep-blue);background:rgba(26,58,110,0.08)}\n.section-tab.active{color:#fff;background:var(--deep-blue);font-weight:600}\n.slider-container{position:relative}\n.slider-card{display:none;animation:fadeIn .35s ease both}\n.slider-card.active{display:block}\n.risk-table{width:100%;border-collapse:collapse;font-size:0.85rem;margin:12px 0}\n.risk-table th{background:#e8e8ec;color:var(--text-dark);padding:10px 12px;text-align:left;font-weight:600}\n.risk-table td{padding:10px 12px;border-bottom:1px solid #eee}\n.risk-table .risk-level{font-weight:700;font-size:0.8rem;padding:2px 8px;border-radius:4px}\n.risk-table .risk-low{background:#e8f5e9;color:#2e7d32}\n.risk-table .risk-mid{background:#fff3e0;color:#e65100}\n.risk-table .risk-high{background:#fce4ec;color:#c62828}\n\/* ===== \u6a21\u5757\u4e09.3\uff1a\u79fb\u52a8\u7aef\u7eafCSS\u6298\u53e0 ===== *\/\n.fold-cb{position:absolute;opacity:0;pointer-events:none}\n.fold-body{display:none}\n.fold-cb:checked ~ .fold-body{display:block}\n.fold-lbl{display:block;cursor:pointer}\n.fold-lbl .step-head{margin-bottom:18px}\n.fold-ico{float:right;color:var(--gold);font-weight:700;font-size:1.1rem;margin-left:10px}\n@media(min-width:769px){\n  .fold-body{display:block !important}\n  .fold-lbl{cursor:default}\n  .fold-ico{display:none}\n}\n@media(max-width:768px){\n  .hero{aspect-ratio:2.4\/1;min-height:200px;max-height:none}\n  .hero-info-card{gap:10px;padding:12px 16px}\n  .hero-info-item{min-width:64px}\n  .toc{flex-wrap:wrap;height:auto}\n  .toc-wrapper{position:static}\n  .toc-btn{flex:1 1 33%;padding:10px 6px;font-size:0.78rem}\n  .step-section{padding:24px 12px 4px}\n  .content-card{padding:18px 16px}\n  .geo-grid{grid-template-columns:repeat(2,1fr)}\n  .info-table,.compare-table{font-size:0.75rem}\n  .info-table th,.info-table td,.compare-table th,.compare-table td{padding:6px 8px}\n  .advantage-grid{grid-template-columns:1fr}\n  .promise-grid{grid-template-columns:1fr 1fr}\n  .timeline{flex-wrap:wrap;gap:8px}\n  .timeline-step{flex:0 0 auto}\n  .timeline::before{display:none}\n  .step-all-photos-grid,.step-all-photos-grid.cols-6{grid-template-columns:repeat(2,1fr);gap:8px}\n  .photo-grid-land{grid-template-columns:repeat(2,1fr)}\n  .photo-grid-h.cols-3,.photo-grid-h.cols-4,.photo-grid-h.cols-6{grid-template-columns:repeat(2,1fr);gap:8px}\n  .photo-grid-h.cols-2{grid-template-columns:1fr}\n  .auth-grid{grid-template-columns:repeat(2,1fr);gap:10px}\n  .store-grid{grid-template-columns:1fr;gap:10px}\n  .store-cta-wrap{padding:20px 16px;margin:24px auto 12px}\n  .phone-cards{flex-direction:column;align-items:center;gap:12px}\n  .action-row{flex-direction:column;gap:14px}\n}\n\/* ===== \u5403\u8c46\u4eba\u8212\u9002\u76ee\u6807\u53ef\u89c6\u5316 ===== *\/\n.pacman-track{position:relative;display:flex;justify-content:space-between;align-items:flex-start;padding:32px 18px 14px;margin:10px 0 20px;background:#fffbf0;border:1px dashed #ead6a8;border-radius:14px;min-height:96px}\n.pac-path{position:absolute;top:40px;left:34px;right:34px;height:4px;background:repeating-linear-gradient(90deg,#e0d0a8 0 8px,transparent 8px 16px);border-radius:2px}\n.pac-dot{display:flex;flex-direction:column;align-items:center;gap:8px;cursor:pointer;position:relative;z-index:3;width:18%;transition:transform .2s}\n.pac-dot:hover{transform:translateY(-3px)}\n.pac-dot .dot{width:20px;height:20px;border-radius:50%;background:#f4c430;box-shadow:0 0 0 3px #fff,0 2px 5px rgba(0,0,0,.12);transition:.25s}\n.pac-dot.active .dot{transform:scale(.45);opacity:.2}\n.pac-dot .dot-label{font-size:.72rem;color:#5a4a2a;font-weight:700;text-align:center;line-height:1.25;display:flex;align-items:center;justify-content:center;gap:3px}\n.goal-ico{width:14px;height:14px;color:#c5a55a;flex:0 0 auto}\n.goal-ico svg{width:100%;height:100%;display:block}\n.pacman{position:absolute;top:24px;width:36px;height:36px;border-radius:50%;background:transparent;filter:drop-shadow(0 2px 4px rgba(0,0,0,.18));transition:left .7s cubic-bezier(.25,.8,.25,1);z-index:5}\n.pacman::before,.pacman::after{content:'';position:absolute;left:0;width:100%;height:50%;background:#f4c430;border-radius:100px 100px 0 0;transform-origin:50% 100%;animation:munch .35s infinite alternate}\n.pacman::before{top:0}\n.pacman::after{top:50%;border-radius:0 0 100px 100px;transform-origin:50% 0;animation:munch2 .35s infinite alternate}\n.pacman-eye{position:absolute;width:5px;height:5px;background:#2a2a2a;border-radius:50%;top:6px;right:9px;z-index:6}\n@keyframes munch{from{transform:rotate(0)}to{transform:rotate(-38deg)}}\n@keyframes munch2{from{transform:rotate(0)}to{transform:rotate(38deg)}}\n.pacman-detail{background:#fff;border:1px solid #eee;border-radius:12px;padding:16px 18px;margin-top:4px}\n.detail-title{display:flex;align-items:center;gap:10px;font-size:1.05rem;font-weight:700;color:#5a4a2a;margin-bottom:10px}\n.detail-title .mini-pac{display:inline-flex;width:20px;height:20px;color:#f4c430;align-items:center}\n.detail-title .mini-pac svg{width:100%;height:100%}\n.detail-title .stars{color:#c5a55a;font-size:.9rem;letter-spacing:1px}\n.detail-body{font-size:.9rem;color:#444;line-height:1.7}\n@media(max-width:640px){\n  .pacman-track{padding:28px 10px 12px;min-height:82px}\n  .pac-path{top:36px;left:24px;right:24px}\n  .pacman{top:22px;width:30px;height:30px}\n  .pacman-eye{top:5px;right:7px;width:4px;height:4px}\n  .pac-dot .dot{width:16px;height:16px}\n  .pac-dot .dot-label{font-size:.64rem}\n  .pacman-detail{padding:14px}\n}\n<\/style>\n\n<section class=\"hero\" id=\"hero\">\n  <div class=\"hero-inner\">\n    <div class=\"hero-tagline\">\u9f99\u8109\u6696\u901a \u00b7 \u771f\u5b9e\u6848\u4f8b<\/div>\n    <h2 class=\"hero-title\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\uff5c\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 \u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b-\u9f99\u8109\u6696\u901a<\/h2>\n    <p class=\"hero-subtitle\">\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ \u4e00\u62d6\u4e94 \u00b7 \u5e73\u5c42103.87\u33a1 \u00b7 APF 5.80\u4e00\u7ea7\u80fd\u6548 \u00b7 \u914d\u7f6e\u5355\u9a71\u52a8\u7684\u7cbe\u51c6\u9009\u578b<\/p>\n    <div class=\"hero-info-card\">\n      <div class=\"hero-info-item\"><div class=\"label\">\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"value\">103.87\u33a1<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u7a7a\u8c03\u7cfb\u7edf<\/div><div class=\"value\">\u65e5\u7acb\u8212\u4eab160<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u5916\u673a\u578b\u53f7<\/div><div class=\"value\">RAS-160HRNAQ<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u5185\u673a\u6570\u91cf<\/div><div class=\"value\">\u4e00\u62d6\u4e94<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u80fd\u6548\u6307\u6807<\/div><div class=\"value\">APF 5.80<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u603b\u5236\u51b7\u91cf<\/div><div class=\"value\">18500W<\/div><\/div>\n    <\/div>\n    <p style=\"font-size:0.75rem;color:rgba(255,255,255,0.5);margin-top:8px\">\u6848\u4f8b\u66f4\u65b0\u65f6\u95f4\uff1a2026\u5e7408\u6708<\/p>\n  <\/div>\n<\/section>\n\n<div class=\"toc-wrapper\" id=\"tocwrap\">\n  <nav class=\"toc\">\n    <button class=\"toc-btn\" data-target=\"s1\">S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807<span class=\"toc-caret\">\u25be<\/span><\/button>\n    <button class=\"toc-btn\" data-target=\"s2\">S2\u00b7\u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad<span class=\"toc-caret\">\u25be<\/span><\/button>\n    <button class=\"toc-btn\" data-target=\"s3\">S3\u00b7\u89e3\u51b3\u65b9\u6848\u8be6\u89e3<span class=\"toc-caret\">\u25be<\/span><\/button>\n    <button class=\"toc-btn\" data-target=\"s4\">S4\u00b7\u65bd\u5de5\u4ea4\u4ed8\u4fdd\u969c<span class=\"toc-caret\">\u25be<\/span><\/button>\n    <button class=\"toc-btn\" data-target=\"s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1\u8fed\u4ee3<span class=\"toc-caret\">\u25be<\/span><\/button>\n  <\/nav>\n  <div class=\"subtoc\" id=\"subtoc\">\n    <div class=\"subtoc-panel\" data-panel=\"s1\">\n      <a href=\"#s1-h1\">\u5ba2\u6237\u4fe1\u606f\u5361<\/a>\n      <a href=\"#s1-h2\">\u8212\u9002\u76ee\u6807<\/a>\n      <a href=\"#s1-h3\">\u9879\u76ee\u6982\u51b5<\/a>\n      <a href=\"#s1-h4\">\u670d\u52a1\u7406\u5ff5<\/a>\n    <\/div>\n    <div class=\"subtoc-panel\" data-panel=\"s2\">\n      <a href=\"#s2-h1\">\u6c14\u5019\u4e0e\u5236\u51b7\u75db\u70b9<\/a>\n      <a href=\"#s2-h2\">\u8bbe\u8ba1\u539f\u5219<\/a>\n      <a href=\"#s2-h3\">\u9010\u623f\u95f4\u51b7\u8d1f\u8377\u6d4b\u7b97<\/a>\n      <a href=\"#s2-h4\">\u4e3a\u4ec0\u4e48\u9009\u8212\u4eab160<\/a>\n      <a href=\"#s2-h5\">\u8bbe\u8ba1\u4f9d\u636e<\/a>\n    <\/div>\n    <div class=\"subtoc-panel\" data-panel=\"s3\">\n      <a href=\"#s3-h1\">\u8212\u4eab160\u65b9\u6848\u914d\u7f6e<\/a>\n      <a href=\"#s3-h2\">\u4e00\u62d6\u4e94\u65b9\u6848\u5bf9\u6bd4<\/a>\n      <a href=\"#s3-h3\">\u900f\u660e\u8bf4\u660e<\/a>\n    <\/div>\n    <div class=\"subtoc-panel\" data-panel=\"s4\">\n      <a href=\"#s4-h1\">\u516d\u6b65\u7cbe\u5de5\u6d41\u7a0b<\/a>\n      <a href=\"#s4-h2\">\u65bd\u5de5\u5b9e\u62cd\u56fe\u96c6<\/a>\n      <a href=\"#s4-h3\">\u9f99\u8109\u7cbe\u5de5\u5bf9\u6bd4<\/a>\n      <a href=\"#s4-h4\">\u9690\u853d\u9a8c\u6536\u7ec6\u8282<\/a>\n      <a href=\"#s4-h5\">\u4ea4\u4ed8\u6559\u5b66\u4e0e\u552e\u540e<\/a>\n      <a href=\"#s4-h6\">\u54c1\u724c\u6388\u6743\u8ba4\u8bc1<\/a>\n    <\/div>\n    <div class=\"subtoc-panel\" data-panel=\"s5\">\n      <a href=\"#s5-h1\">\u6848\u4f8b\u590d\u76d8<\/a>\n      <a href=\"#s5-h2\">\u9f99\u8109\u4e13\u4e1a\u4e3b\u5f20<\/a>\n      <a href=\"#s5-h3\">\u98ce\u9669\u544a\u77e5<\/a>\n      <a href=\"#s5-h4\">\u6696\u901a\u8d34\u58eb<\/a>\n      <a href=\"#s5-h5\">\u5ba2\u6237\u6c9f\u901a\u5b9e\u5f55<\/a>\n      <a href=\"#s5-h6\">\u6696\u901a\u95ee\u7b54<\/a>\n      <a href=\"#s5-faq\">\u5e38\u89c1\u95ee\u9898FAQ<\/a>\n    <\/div>\n  <\/div>\n<\/div>\n\n<div class=\"geo-card\">\n  <div class=\"geo-title\">\ud83d\udccd \u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 \u00b7 \u9879\u76ee\u4fe1\u606f\u5361<\/div>\n  <div class=\"geo-grid\">\n    <div class=\"geo-item\"><div class=\"g-lbl\">\u5b8c\u6574\u697c\u76d8\u5730\u5740<\/div><div class=\"g-val\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8<\/div><\/div>\n    <div class=\"geo-item\"><div class=\"g-lbl\">\u623f\u5c4b\u53c2\u6570<\/div><div class=\"g-val\">\u5e73\u5c42\uff0c\u5c42\u9ad8\u7ea62.9\u7c73\uff0c\u7a7a\u8c03\u9762\u79ef103.87\u33a1\uff08\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1 \/ \u5bb6\u5ead\u5ba430.9\u33a1 \/ \u4e3b\u536715.3\u33a1 \/ \u6b21\u536714.27\u33a1\uff09<\/div><\/div>\n    <div class=\"geo-item\"><div class=\"g-lbl\">\u4e1a\u4e3b\u753b\u50cf<\/div><div class=\"g-val\">\u8521\u8001\u5e08\uff0c\u6ce8\u91cd\u914d\u7f6e\u5355\u7cbe\u51c6\u5ea6\u4e0e\u957f\u671f\u54c1\u8d28\uff0c\u8ffd\u6c42\u5236\u51b7\u7a33\u5b9a\u3001\u8fd0\u884c\u5b89\u9759\u3001\u80fd\u6548\u7701\u7535<\/div><\/div>\n    <div class=\"geo-item\"><div class=\"g-lbl\">\u9875\u9762\u66f4\u65b0\u65f6\u95f4<\/div><div class=\"g-val\">2026\u5e7408\u6708<\/div><\/div>\n    <div class=\"geo-item full\"><div class=\"g-lbl\">\u7cfb\u7edf\u914d\u7f6e\u6458\u8981<\/div><div class=\"g-val\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 RAS-160HRNAQ \u5355\u98ce\u6247\u5916\u673a \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff08RPIZ-50FSNAQD\/P 5000W + RPIZ-22FSNAQD\/P 2200W \u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\uff1bRPIZ-63FSNAQD\/P 6300W \u5bb6\u5ead\u5ba4\uff1bRPIZ-25FSNAQD\/P 2500W \u4e3b\u5367\uff1bRPIZ-25FSNAQD\/P 2500W \u6b21\u5367\uff09\uff0c\u603b\u5236\u51b7\u91cf18500W\uff0c\u8fde\u63a5\u7387119.4%\uff0cAPF 5.80\uff0c\u566a\u97f3\u503c54dB(A)\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c\u5236\u51b7\u8303\u56f4-5~59\u2103\/\u5236\u70ed-23~17\u2103<\/div><\/div>\n    <div class=\"geo-item full\"><div class=\"g-lbl\">\u5dee\u5f02\u5316\u6807\u7b7e<\/div><div class=\"g-val\">\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u9ad8\u7aef\u5e73\u5c42 \u00b7 \u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u53cc\u5185\u673a7200W\u5206\u533a\u63a7\u6e29 \u00b7 \u5bb6\u5ead\u5ba430.9\u33a1\u914d\u7f6e63\u5927\u5185\u673a204W\/\u33a1 \u00b7 \u8fde\u63a5\u7387119.4%\u5168\u5c4b\u540c\u5f00\u6709\u4f59\u91cf \u00b7 APF 5.80\u4e00\u7ea7\u80fd\u6548 \u00b7 \u5355\u98ce\u6247\u5916\u673a\u9002\u914d\u9ad8\u7aef\u697c\u76d8\u5916\u673a\u4f4d \u00b7 \u7eaf\u4e2d\u592e\u7a7a\u8c03\u7b80\u6d01\u9ad8\u6548<\/div><\/div>\n    <div class=\"geo-item full\"><div class=\"g-lbl\">\u65bd\u5de5\u8986\u76d6\u8303\u56f4<\/div><div class=\"g-val\">\u6210\u90fd\u5168\u57df\uff08\u9ad8\u65b0\u3001\u6b66\u4faf\u3001\u6210\u534e\u3001\u9526\u6c5f\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u3001\u6e29\u6c5f\u7b49\u533a\u53bf\u4e0a\u95e8\u65bd\u5de5\uff09<\/div><\/div>\n    <div class=\"geo-item full\"><div class=\"g-lbl\">\u95e8\u5e97 &amp; \u54a8\u8be2\u89e6\u70b9<\/div><div class=\"g-val\">\u5357\u5bcc\u68ee\u5e97 \/ \u5317\u5bcc\u68ee\u5e97\u53cc\u95e8\u5e97 \u00b7 \u5ea7\u673a 028-86131795 \u00b7 \u672c\u6848\u4f8b\u987e\u95ee\u4f59\u6653\u73b2 130-0811-3409<\/div><\/div>\n  <\/div>\n<\/div>\n\n<div class=\"kw-block\">\n  <strong style=\"color:#f0e2c0\">\u6838\u5fc3\u5173\u952e\u8bcd\uff1a<\/strong>\n  <span class=\"kw-tag\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u6696\u901a<\/span>\n  <span class=\"kw-tag\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u65e5\u7acb\u8212\u4eab160<\/span>\n  <span class=\"kw-tag\">\u65e5\u7acbRAS-160HRNAQ\u4e00\u62d6\u4e94<\/span>\n  <span class=\"kw-tag\">\u5e73\u5c42\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848<\/span>\n  <span class=\"kw-tag\">APF5.80\u9ad8\u80fd\u6548\u7a7a\u8c03<\/span>\n  <span class=\"kw-tag\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5<\/span>\n  <span class=\"kw-tag\">\u65e5\u7acb\u8212\u4eab\u5185\u673a\u5b89\u88c5<\/span>\n  <span class=\"kw-tag\">\u9f99\u8109\u6696\u901a\u94bb\u77f3\u5b89\u88c5\u5546<\/span>\n  <span class=\"kw-tag\">\u603b\u5236\u51b7\u91cf18500W\u7cbe\u786e\u8bbe\u8ba1<\/span>\n<\/div>\n\n<main>\n\n  <section class=\"step-section\" id=\"s1\">\n    <input type=\"checkbox\" id=\"fold-s1\" class=\"fold-cb\">\n    <label for=\"fold-s1\" class=\"fold-lbl\"><h2 class=\"step-head\">S1 \u00b7 \u4e1a\u4e3b\u5c45\u4f4f\u76ee\u6807\u4e0e\u8212\u9002\u9700\u6c42<span class=\"fold-ico\">\u25be \u5c55\u5f00\/\u6536\u8d77<\/span><\/h2><\/label>\n    <div class=\"fold-body\">\n      <div class=\"quote-strong\">\"\u6211\u5bf9\u7740\u914d\u7f6e\u5355\u4e00\u9879\u9879\u770b\uff0c\u9762\u79ef\u3001\u51b7\u6307\u6807\u3001\u5185\u673a\u578b\u53f7\u3001\u8fde\u63a5\u7387\u90fd\u8981\u5bf9\u5f97\u4e0a\u3002\u623f\u5b50\u5728\u9e93\u6e56\uff0c\u88c5\u4e00\u6b21\u8981\u7528\u5341\u51e0\u5e74\uff0c\u5e0c\u671b\u65b9\u6848\u7cbe\u51c6\u3001\u4e0d\u6d6a\u8d39\u3001\u4e5f\u4e0d\u8fc7\u8f7d\u3002\"\u2014\u2014\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8521\u8001\u5e08\uff08\u5ba2\u6237\u8bc9\u6c42\u6846\u67b6\uff09<\/div>\n\n      <div class=\"section-tabs\">\n        <span class=\"section-tab active\" data-t=\"info\">\u5ba2\u6237\u4fe1\u606f\u5361<\/span>\n        <span class=\"section-tab\" data-t=\"goal\">\u8212\u9002\u76ee\u6807<\/span>\n        <span class=\"section-tab\" data-t=\"overview\">\u9879\u76ee\u6982\u51b5<\/span>\n        <span class=\"section-tab\" data-t=\"service\">\u670d\u52a1\u7406\u5ff5<\/span>\n      <\/div>\n\n      <div class=\"flip-card\" id=\"infoGoalFlip\">\n        <div class=\"flip-card-inner\">\n          <div class=\"flip-front info-goal-front\">\n            <h3 class=\"card-title\" id=\"s1-h1\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n            <div class=\"info-block\">\n              <div class=\"info-block-h\">\ud83c\udfe0 \u7b2c\u4e00\u6392 \u00b7 \u5efa\u7b51\u4fe1\u606f<\/div>\n              <div class=\"info-row\">\n                <div class=\"info-cell\"><div class=\"lbl\">\u5c0f\u533a<\/div><div class=\"val\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8<\/div><\/div>\n                <div class=\"info-cell\"><div class=\"lbl\">\u5ba2\u6237<\/div><div class=\"val\">\u8521\u8001\u5e08<\/div><\/div>\n                <div class=\"info-cell\"><div class=\"lbl\">\u9879\u76ee\u5730\u5740<\/div><div class=\"val\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\uff08\u8131\u654f\uff09<\/div><\/div>\n                <div class=\"info-cell\"><div class=\"lbl\">\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"val\">103.87\u33a1\uff08\u5e73\u5c42\u56db\u533a\u57df\uff09<\/div><\/div>\n                <div class=\"info-cell\"><div class=\"lbl\">\u6237\u578b<\/div><div class=\"val\">\u5e73\u5c42\uff0c\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f \/ \u5bb6\u5ead\u5ba4 \/ \u4e3b\u5367 \/ \u6b21\u5367<\/div><\/div>\n              <\/div>\n            <\/div>\n            <div class=\"info-block\">\n              <div class=\"info-block-h\">\ud83d\udc64 \u7b2c\u4e8c\u6392 \u00b7 \u5c45\u4f4f\u4e60\u60ef<\/div>\n        <div class=\"info-row\">\n          <div class=\"info-cell\"><div class=\"lbl\">\u5e38\u4f4f\u4eba\u53e3<\/div><div class=\"val\">3~4\u4eba\uff08\u8521\u8001\u5e08\u5bb6\u5ead\uff09<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u767d\u5929\u4f7f\u7528<\/div><div class=\"val\">\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u3001\u5bb6\u5ead\u5ba4\u6d3b\u52a8\u9891\u7e41\uff0c\u5bf9\u516c\u5171\u533a\u57df\u5236\u51b7\u8981\u6c42\u9ad8<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u665a\u95f4\u4f7f\u7528<\/div><div class=\"val\">\u4e3b\u5367+\u6b21\u5367\u72ec\u7acb\u5f00\u542f\uff0c\u8ffd\u6c42\u5b89\u9759\u8fd0\u884c<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u6838\u5fc3\u9700\u6c42<\/div><div class=\"val\">\u914d\u7f6e\u7cbe\u51c6\u3001\u5236\u51b7\u7a33\u5b9a\u3001\u8fd0\u884c\u5b89\u9759\u3001\u957f\u671f\u7701\u7535<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u51b3\u7b56\u98ce\u683c<\/div><div class=\"val\">\u9ad8\u5ea6\u4fe1\u4efb\u6570\u636e\u4e0e\u914d\u7f6e\u5355\uff0c\u9010\u9879\u6838\u5bf9\u9762\u79ef\u3001\u51b7\u6307\u6807\u3001\u578b\u53f7<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u697c\u76d8\u5c5e\u6027<\/div><div class=\"val\">\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u9ad8\u7aef\u5e73\u5c42\uff0c\u5bf9\u54c1\u8d28\u4e0e\u7f8e\u89c2\u5ea6\u8981\u6c42\u9ad8<\/div><\/div>\n        <\/div>\n            <\/div>\n            <div class=\"info-block\">\n              <div class=\"info-block-h\">\ud83c\udfaf \u7b2c\u4e09\u6392 \u00b7 \u9700\u6c42\u75db\u70b9<\/div>\n              <div class=\"promise-grid\" style=\"margin-top:10px\">\n                <div class=\"promise-card\">\n                  <div class=\"promise-num\">01<\/div>\n                  <div class=\"promise-title\">\u914d\u7f6e\u8981\u7cbe\u51c6<\/div>\n                  <div class=\"promise-desc\">\u5e0c\u671b\u6bcf\u4e00\u9879\u53c2\u6570\u90fd\u6709\u636e\u53ef\u4f9d\uff0c\u5185\u673a\u5bb9\u91cf\u4e0e\u623f\u95f4\u9762\u79ef\u4e00\u4e00\u5bf9\u5e94\uff0c\u4e0d\u76f2\u76ee\u653e\u5927\u3002<\/div>\n                <\/div>\n                <div class=\"promise-card\">\n                  <div class=\"promise-num\">02<\/div>\n                  <div class=\"promise-title\">\u5927\u516c\u533a\u8981\u51c9\u5f97\u5747\u5300<\/div>\n                  <div class=\"promise-desc\">\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u3001\u5bb6\u5ead\u5ba430.9\u33a1\u90fd\u662f\u4e3b\u8981\u6d3b\u52a8\u533a\uff0c\u9700\u8981\u5feb\u901f\u5747\u5300\u964d\u6e29\u3002<\/div>\n                <\/div>\n                <div class=\"promise-card\">\n                  <div class=\"promise-num\">03<\/div>\n                  <div class=\"promise-title\">\u8fd0\u884c\u8981\u5b89\u9759<\/div>\n                  <div class=\"promise-desc\">\u5bf9\u5ba4\u5185\u673a\u566a\u97f3\u654f\u611f\uff0c\u5c24\u5176\u4e3b\u5367\u3001\u6b21\u5367\u591c\u95f4\u8fd0\u884c\u5fc5\u987b\u4f4e\u566a\u3002<\/div>\n                <\/div>\n                <div class=\"promise-card\">\n                  <div class=\"promise-num\">04<\/div>\n                  <div class=\"promise-title\">\u957f\u671f\u80fd\u8017\u8981\u53ef\u63a7<\/div>\n                  <div class=\"promise-desc\">\u6210\u90fd\u590f\u5b63\u5236\u51b7\u5b63\u957f\uff0c\u7a7a\u8c03\u9ad8\u9891\u4f7f\u7528\uff0c\u4e00\u7ea7\u80fd\u6548\u4e0e\u53d8\u9891\u8c03\u8282\u662f\u5173\u952e\u3002<\/div>\n                <\/div>\n                <div class=\"promise-card\">\n                  <div class=\"promise-num\">05<\/div>\n                  <div class=\"promise-title\">\u5916\u673a\u4f4d\u8981\u9002\u914d<\/div>\n                  <div class=\"promise-desc\">\u9ad8\u7aef\u697c\u76d8\u5916\u673a\u4f4d\u7a7a\u95f4\u6709\u9650\uff0c\u9700\u8981\u5355\u98ce\u6247\u7d27\u51d1\u5916\u673a\uff0c\u9884\u7559\u6563\u70ed\u4e0e\u7ef4\u62a4\u7a7a\u95f4\u3002<\/div>\n                <\/div>\n              <\/div>\n            <\/div>\n            <div class=\"info-block\">\n              <div class=\"info-block-h\">\ud83d\udcac \u7b2c\u56db\u6392 \u00b7 \u5ba2\u6237\u89c2\u70b9<\/div>\n              <div class=\"quote\">\u8521\u8001\u5e08\u62ff\u7740\u9f99\u8109\u6696\u901a\u51fa\u5177\u7684\u914d\u7f6e\u5355\uff0c\u9010\u884c\u6838\u5bf9\u623f\u95f4\u9762\u79ef\u3001\u8bbe\u8ba1\u51b7\u6307\u6807\u3001\u5185\u673a\u578b\u53f7\u4e0e\u5b9e\u9645\u51b7\u6307\u6807\u3002\u4ed6\u8ba4\u4e3a\uff1a\u9e93\u6e56\u7684\u623f\u5b50\u88c5\u4fee\u6295\u5165\u5927\uff0c\u4e2d\u592e\u7a7a\u8c03\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u5bb9\u4e0d\u5f97\"\u5dee\u4e0d\u591a\"\uff1b\u53ea\u6709\u914d\u7f6e\u5355\u4e0a\u6bcf\u4e00\u9879\u90fd\u5bf9\u5f97\u4e0a\uff0c\u540e\u671f\u4f7f\u7528\u624d\u8e0f\u5b9e\u3002\u5bf9\u6bd4\u540e\u8ba4\u53ef\u9f99\u8109\u65b9\u6848\u7684\u6570\u636e\u5316\u8868\u8fbe\u4e0e\u65bd\u5de5\u6807\u51c6\uff0c\u6700\u7ec8\u9009\u5b9a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u3002<\/div>\n            <\/div>\n          <\/div>\n          <div class=\"flip-back\">\n            <h3 class=\"card-title\" id=\"s1-h2\">\u8521\u8001\u5e08\u7684\u8212\u9002\u76ee\u6807<\/h3>\n            <div class=\"pacman-track\" id=\"pacmanTrack\">\n              <div class=\"pac-path\"><\/div>\n              <div class=\"pacman\" id=\"pacman\"><div class=\"pacman-eye\"><\/div><\/div>\n              <div class=\"pac-dot active\" data-title=\"\u590f\u5b63\u5236\u51b7\" data-stars=\"\u2605\u2605\u2605\u2605\u2605\" data-text=\"\u6210\u90fd\u590f\u5b63\u95f7\u70ed\u9ad8\u6e7f\uff0c\u5e73\u5c42103.87\u33a1\u9700\u8981\u5145\u8db3\u5236\u51b7\u91cf\u3002\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u914d\u7f6e50+22\u4e24\u53f0\u5185\u673a\uff087200W\uff09\uff0c\u5bb6\u5ead\u5ba430.9\u33a1\u914d\u7f6e63\u5185\u673a\uff086300W\uff09\uff0c\u4e3b\u536715.3\u33a1\u4e0e\u6b21\u536714.27\u33a1\u5404\u914d25\u5185\u673a\uff082500W\uff09\uff0c\u6309\u5b9e\u9645\u8d1f\u8377\u7cbe\u51c6\u9009\u578b\uff0c\u907f\u514d\u8fc7\u5927\u6216\u8fc7\u5c0f\u3002\">\n                <span class=\"dot\"><\/span><span class=\"dot-label\">\u590f\u5b63\u5236\u51b7<\/span>\n              <\/div>\n              <div class=\"pac-dot\" data-title=\"\u8fd0\u884c\u5b89\u9759\" data-stars=\"\u2605\u2605\u2605\u2605\u2605\" data-text=\"\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5ba4\u5185\u673a\u4f4e\u566a\u8fd0\u884c\uff0c\u4e0d\u5f71\u54cd\u5bb6\u4eba\u4f11\u606f\u4e0e\u65e5\u5e38\u6d3b\u52a8\u3002\u5916\u673a\u653e\u7f6e\u5728\u5408\u7406\u4f4d\u7f6e\uff0c\u8fdc\u79bb\u5367\u5ba4\u7a97\u6237\uff0c\u566a\u97f3\u4ec554dB(A)\u3002\">\n                <span class=\"dot\"><\/span><span class=\"dot-label\">\u8fd0\u884c\u5b89\u9759<\/span>\n              <\/div>\n              <div class=\"pac-dot\" data-title=\"\u7a33\u5b9a\u7701\u5fc3\" data-stars=\"\u2605\u2605\u2605\u2605\u2605\" data-text=\"\u4e00\u62d6\u4e94\u591a\u8054\u673a\u7ed3\u6784\u7b80\u5355\u3001\u6545\u969c\u70b9\u5c11\uff0c\u65e5\u7acb\u539f\u5382\u54c1\u8d28+\u9f99\u8109\u6696\u901a\u4e13\u4e1a\u5b89\u88c5\u53cc\u91cd\u4fdd\u969c\uff0c\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\u3002\">\n                <span class=\"dot\"><\/span><span class=\"dot-label\">\u7a33\u5b9a\u7701\u5fc3<\/span>\n              <\/div>\n              <div class=\"pac-dot\" data-title=\"\u8282\u80fd\u7701\u7535\" data-stars=\"\u2605\u2605\u2605\u2605\u2605\" data-text=\"RAS-160HRNAQ\u5916\u673aAPF\u8fbe5.80\uff08\u65b0\u56fd\u6807\u4e00\u7ea7\u80fd\u6548\uff09\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u6548\u7387\u9ad8\uff0c\u957f\u671f\u4f7f\u7528\u7535\u8d39\u53ef\u63a7\u3002\">\n                <span class=\"dot\"><\/span><span class=\"dot-label\">\u8282\u80fd\u7701\u7535<\/span>\n              <\/div>\n              <div class=\"pac-dot\" data-title=\"\u64cd\u4f5c\u7b80\u5355\" data-stars=\"\u2605\u2605\u2605\u2605\u2605\" data-text=\"5\u53f0\u5185\u673a\u72ec\u7acb\u7ebf\u63a7\uff0c\u767d\u5929\u516c\u533a\u540c\u5f00\u3001\u665a\u4e0a\u5367\u5ba4\u72ec\u7acb\u8fd0\u884c\uff0c\u6781\u7aef\u60c5\u51b55\u53f0\u540c\u5f0018500W\uff0c\u8fde\u63a5\u7387119.4%\u4ece\u5bb9\u5e94\u5bf9\u3002\">\n                <span class=\"dot\"><\/span><span class=\"dot-label\">\u64cd\u4f5c\u7b80\u5355<\/span>\n              <\/div>\n            <\/div>\n            <div class=\"pacman-detail\" id=\"pacmanDetail\">\n              <div class=\"detail-title\"><span class=\"mini-pac\"><\/span><span class=\"d-title\">\u590f\u5b63\u5236\u51b7<\/span><span class=\"stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/div>\n              <div class=\"detail-body\">\u6210\u90fd\u590f\u5b63\u95f7\u70ed\u9ad8\u6e7f\uff0c\u5e73\u5c42103.87\u33a1\u9700\u8981\u5145\u8db3\u5236\u51b7\u91cf\u3002\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u914d\u7f6e50+22\u4e24\u53f0\u5185\u673a\uff087200W\uff09\uff0c\u5bb6\u5ead\u5ba430.9\u33a1\u914d\u7f6e63\u5185\u673a\uff086300W\uff09\uff0c\u4e3b\u536715.3\u33a1\u4e0e\u6b21\u536714.27\u33a1\u5404\u914d25\u5185\u673a\uff082500W\uff09\uff0c\u6309\u5b9e\u9645\u8d1f\u8377\u7cbe\u51c6\u9009\u578b\uff0c\u907f\u514d\u8fc7\u5927\u6216\u8fc7\u5c0f\u3002<\/div>\n            <\/div>\n            <div class=\"flip-hint\">\ud83d\udc46 \u70b9\u51fb\u5361\u7247\u4efb\u610f\u4f4d\u7f6e\u7ffb\u56de\u300c\u5ba2\u6237\u4fe1\u606f\u5361\u300d<\/div>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\" data-t=\"overview\">\n        <h3 class=\"card-title\" id=\"s1-h3\">\u9879\u76ee\u6982\u51b5<\/h3>\n        <p>\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8521\u8001\u5e08\u4f4f\u5b85\uff0c\u5e73\u5c42\u6237\u578b\uff0c\u7a7a\u8c03\u9762\u79ef<b class=\"bold-spec\">103.87\u33a1<\/b>\u3002\u6237\u578b\u7279\u70b9\uff1a<b class=\"bold-spec\">\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u3001\u5bb6\u5ead\u5ba430.9\u33a1\u3001\u4e3b\u536715.3\u33a1\u3001\u6b21\u536714.27\u33a1<\/b>\uff0c\u516c\u5171\u533a\u57df\u5360\u6bd4\u5927\uff0c\u662f\u672c\u6848\u51b7\u8d1f\u8377\u8bbe\u8ba1\u7684\u6838\u5fc3\u3002\u8521\u8001\u5e08\u51b3\u7b56\u98ce\u683c\u7406\u6027\uff0c\u91cd\u89c6\u914d\u7f6e\u5355\u7684\u6570\u636e\u5339\u914d\u3002\u6700\u7ec8\u9009\u7528<b class=\"bold-spec\">\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ\u4e00\u62d6\u4e94<\/b>\u4e2d\u592e\u7a7a\u8c03\uff0c\u603b\u5236\u51b7\u91cf18500W\uff0c\u8fde\u63a5\u7387119.4%\uff0cAPF 5.80\uff0c\u6ee1\u8db3\"\u7cbe\u51c6\u3001\u7a33\u5b9a\u3001\u5b89\u9759\u3001\u7701\u7535\"\u56db\u9879\u6838\u5fc3\u8bc9\u6c42\u3002<\/p>\n        <div class=\"info-row\" style=\"margin-top:14px\">\n          <div class=\"info-cell\"><div class=\"lbl\">\u9879\u76ee\u5730\u5740<\/div><div class=\"val\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u9879\u76ee\u72b6\u6001<\/div><div class=\"val\">\u5df2\u5b8c\u5de5\u4ea4\u4ed8<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u65bd\u5de5\u65b9<\/div><div class=\"val\">\u9f99\u8109\u6696\u901a\uff08\u76f4\u8425\u73ed\u7ec4\uff0c\u65e0\u5916\u5305\uff09<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u65b9\u6848\u987e\u95ee<\/div><div class=\"val\">\u4f59\u6653\u73b2 130-0811-3409\uff08\u5357\u5bcc\u68ee\u4e8c\u53f7\u5e97\u4e09\u697cA\u533a347\/348\uff0c\u5168\u7a0b\u76f4\u8425\u8ddf\u8fdb\uff09<\/div><\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\" data-t=\"service\">\n        <h3 class=\"card-title\" id=\"s1-h4\">\u6211\u4eec\u7684\u670d\u52a1\u7406\u5ff5 \u00b7 \u4e0e\u60a8\u76ee\u6807\u4e00\u81f4<\/h3>\n        <div class=\"review-card\">\n          <p><strong>\u2460 \u914d\u7f6e\u5355\u900f\u660e\uff0c\u9010\u9879\u53ef\u6838\u5bf9\uff1a<\/strong>\u9f99\u8109\u6696\u901a\u51fa\u5177\u7684\u65b9\u6848\u914d\u7f6e\u8868\u5305\u542b\u623f\u95f4\u9762\u79ef\u3001\u8bbe\u8ba1\u51b7\u6307\u6807\u3001\u5185\u673a\u578b\u53f7\u3001\u8bbe\u5907\u51b7\u91cf\u3001\u5b9e\u9645\u51b7\u6307\u6807\u3001\u5916\u673a\u53c2\u6570\u7b49\u5b8c\u6574\u5b57\u6bb5\uff0c\u8521\u8001\u5e08\u53ef\u9010\u9879\u6838\u5bf9\uff0c\u505a\u5230\u5fc3\u4e2d\u6709\u6570\u3002<\/p>\n        <\/div>\n        <div class=\"review-card\">\n          <p><strong>\u2461 \u6309\u8d1f\u8377\u7cbe\u51c6\u9009\u578b\uff0c\u4e0d\u6d6a\u8d39\u4e5f\u4e0d\u8fc7\u8f7d\uff1a<\/strong>\u6309GB 50736-2012\u89c4\u8303\u9010\u623f\u95f4\u6d4b\u7b97\uff1a\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u914d50+22\u4e24\u53f0\u5185\u673a\uff087200W\uff09\u3001\u5bb6\u5ead\u5ba430.9\u33a1\u914d63\uff086300W\uff09\u3001\u4e3b\u536725\uff082500W\uff09\u3001\u6b21\u536725\uff082500W\uff09\uff0c\u603b\u5185\u673a\u5bb9\u91cf18500W\u5bf9\u5e94\u5916\u673a15500W\uff0c\u8fde\u63a5\u7387119.4%\u2014\u2014\u65e2\u6ee1\u8db3\u5f53\u524d\u4f7f\u7528\uff0c\u4e5f\u9884\u7559\u5168\u5c4b\u540c\u5f00\u4f59\u91cf\u3002<\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"step-section\" id=\"s2\">\n    <input type=\"checkbox\" id=\"fold-s2\" class=\"fold-cb\">\n    <label for=\"fold-s2\" class=\"fold-lbl\"><h2 class=\"step-head\">S2 \u00b7 \u6237\u578b\u51b7\u8d1f\u8377\u8bca\u65ad\u4e0e\u65b9\u6848\u8bbe\u8ba1\u4f9d\u636e<span class=\"fold-ico\">\u25be \u5c55\u5f00\/\u6536\u8d77<\/span><\/h2><\/label>\n    <div class=\"fold-body\">\n      <div class=\"content-card\">\n        <h3 class=\"card-title\">\u6210\u90fd\u672c\u5730\u6c14\u5019\u4e0e\u672c\u5957\u5e73\u5c42\u5236\u51b7\u75db\u70b9\u89e3\u8bfb<\/h3>\n        <p>\u6210\u90fd\u5c5e\u4e9a\u70ed\u5e26\u6e7f\u6da6\u6c14\u5019\uff0c\u590f\u5b63<b class=\"bold-spec\">\u95f7\u70ed\u9ad8\u6e7f<\/b>\uff08\u5ba4\u5916\u6e29\u5ea6\u5e38\u8d8535\u2103\u3001\u6e7f\u5ea670%+\uff09\u3001\u51ac\u5b63<b class=\"bold-spec\">\u6e7f\u51b7<\/b>\uff08\u63a5\u8fd10\u2103\u4f46\u4f53\u611f\u66f4\u51b7\uff09\u3002\u672c\u6848\u4e3a<b class=\"bold-spec\">\u5e73\u5c42103.87\u33a1<\/b>\uff0c\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u3001\u5bb6\u5ead\u5ba4\u4e24\u4e2a\u5927\u516c\u533a\u5408\u8ba174.3\u33a1\uff0c\u5360\u603b\u7a7a\u8c03\u9762\u79ef\u768471.5%\uff0c\u662f\u672c\u6848\u51b7\u8d1f\u8377\u8bbe\u8ba1\u7684\u91cd\u4e2d\u4e4b\u91cd\uff1a<\/p>\n        <div class=\"info-row\" style=\"margin-top:10px\">\n          <div class=\"info-cell\"><div class=\"val\">\u590f\u5b63\u95f7\u70ed\u9ad8\u6e7f<\/div><div class=\"lbl\">\u666e\u901a\u67dc\u673a\/\u6302\u673a\u5236\u51b7\u6162\u3001\u9664\u6e7f\u5dee<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val\">\u5927\u516c\u533a74.3\u33a1<\/div><div class=\"lbl\">\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u3001\u5bb6\u5ead\u5ba430.9\u33a1\u9700\u91cd\u70b9\u4fdd\u969c<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val\">\u4e3b\u5367+\u6b21\u5367\u72ec\u7acb\u63a7\u6e29<\/div><div class=\"lbl\">\u4e24\u95f4\u5367\u5ba4\u5206\u522b\u63a7\u5236\u66f4\u7075\u6d3b<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val\">\u5916\u673a\u4f4d\u7a7a\u95f4\u6709\u9650<\/div><div class=\"lbl\">\u9ad8\u7aef\u697c\u76d8\u5916\u673a\u4f4d\u7d27\u51d1\uff0c\u5355\u98ce\u6247\u5916\u673a\u66f4\u9002\u914d<\/div><\/div>\n        <\/div>\n\n        <h3 class=\"card-title\" style=\"margin-top:22px\">\u73b0\u573a\u52d8\u6d4b\u57fa\u7840\u6570\u636e \u00b7 \u6237\u578b\u91cf\u5316<\/h3>\n        <table class=\"info-table\">\n          <tbody><tr><th>\u52d8\u6d4b\u9879<\/th><th>\u5b9e\u6d4b \/ \u8ba4\u5b9a\u7ed3\u679c<\/th><th>\u8bbe\u8ba1\u5f71\u54cd<\/th><\/tr>\n            <tr><td>\u697c\u76d8\u4e0e\u697c\u5c42<\/td><td>\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 \u00b7 \u9ad8\u5c42\/\u5c0f\u9ad8\u5c42\u4f4f\u5b85<\/td><td>\u5916\u673a\u4f4d\u9700\u8003\u8651<b class=\"bold-spec\">\u9ad8\u5c42\u98ce\u538b<\/b>\uff0c\u5355\u98ce\u6247\u5916\u673a 770\u00d7980\u00d7360mm \u9700\u9884\u7559\u2265300mm \u6563\u70ed\u4e0e\u9632\u98ce\u56fa\u5b9a\u7a7a\u95f4<\/td><\/tr>\n            <tr><td>\u5c42\u9ad8<\/td><td>\u7ea62.9\u7c73\uff08\u6807\u51c6\u5c42\u9ad8\uff09<\/td><td>\u5185\u673a\u8d85\u8584\u673a\u8eab 192mm \u540a\u9876\u6613\u9690\u85cf\uff0c\u4e0d\u538b\u4f4e\u7a7a\u95f4\u611f<\/td><\/tr>\n            <tr><td>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f<\/td><td>43.4\u33a1\uff0c\u4e3b\u8981\u6d3b\u52a8\u516c\u533a<\/td><td>\u53cc\u5185\u673a 50+22\uff087200W\uff09\u6309\u6574\u4f53\u7a7a\u95f4\u914d\u51b7\uff0c\u5206\u533a\u63a7\u6e29\u66f4\u7075\u6d3b<\/td><\/tr>\n            <tr><td>\u5bb6\u5ead\u5ba4<\/td><td>30.9\u33a1\uff0c\u72ec\u7acb\u5927\u7a7a\u95f4<\/td><td>RPIZ-63\uff086300W\uff09\u5355\u53f0\u5927\u5185\u673a\uff0c\u5b9e\u9645\u51b7\u6307\u6807204W\/\u33a1<\/td><\/tr>\n            <tr><td>\u4e3b\u5367<\/td><td>15.3\u33a1<\/td><td>RPIZ-25\uff082500W\uff09\uff0c\u5b9e\u9645\u51b7\u6307\u6807163W\/\u33a1<\/td><\/tr>\n            <tr><td>\u6b21\u5367<\/td><td>14.27\u33a1<\/td><td>RPIZ-25\uff082500W\uff09\uff0c\u5b9e\u9645\u51b7\u6307\u6807175W\/\u33a1<\/td><\/tr>\n            <tr><td>\u5916\u5899 \/ \u4fdd\u6e29<\/td><td>\u73b0\u4ee3\u5efa\u7b51\u5916\u4fdd\u6e29\u5c42\uff0c\u4fdd\u6e29\u826f\u597d<\/td><td>\u51b7\u8d1f\u8377\u4ee5\u4eba\u5458\/\u8bbe\u5907\/\u592a\u9633\u8f90\u5c04\u4e3a\u4e3b\uff0c\u8bbe\u8ba1\u51b7\u6307\u6807\u6309 150W\/\u33a1 \u57fa\u51c6\u6d4b\u7b97<\/td><\/tr>\n          <\/tbody><\/table>\n        <p style=\"font-size:0.82rem;color:var(--text-gray);margin-top:8px\">\ud83d\udcd0 \u52d8\u6d4b\u6570\u636e\u6765\u6e90\u4e8e\u9f99\u8109\u6696\u901a\u73b0\u573a\u52d8\u6d4b\u8bb0\u5f55\uff0c\u6237\u578b\u5c3a\u5bf8\u4ee5\u5b9e\u9645\u6d4b\u91cf\u4e3a\u51c6\uff1b\u4e1a\u4e3b\u9690\u79c1\u4fe1\u606f\u5df2\u8131\u654f\u3002<\/p>\n\n        <h3 class=\"card-title\" style=\"margin-top:22px\">\u5236\u70ed\u9700\u6c42\u8bf4\u660e\uff08\u672c\u6848\u4ee5\u5236\u51b7\u4e3a\u4e3b\uff0c\u5236\u70ed\u7531\u7a7a\u8c03\u8986\u76d6\uff09<\/h3>\n        <p>\u6210\u90fd\u5c5e\u590f\u70ed\u51ac\u51b7\u5730\u533a\uff0c\u51ac\u5b63\u6e7f\u51b7\uff08\u63a5\u8fd10\u2103\u4f46\u4f53\u611f\u66f4\u51b7\uff09\u3002\u8521\u8001\u5e08\u5f53\u524d\u9636\u6bb5\u91cd\u70b9\u5728<b class=\"bold-spec\">\u590f\u5b63\u5236\u51b7<\/b>\uff0c\u6545\u65b9\u6848\u4ee5\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u8986\u76d6\u5168\u5c4b\uff1b\u8be5\u5916\u673a\u989d\u5b9a\u5236\u70ed\u91cf <b class=\"bold-spec\">17000W<\/b>\u3001\u5236\u70ed\u80fd\u6548\u5145\u8db3\uff0c\u53ef\u517c\u987e\u51ac\u5b63\u5236\u70ed\u3002\u82e5\u540e\u671f\u6709\u66f4\u9ad8\u8212\u9002\u5ea6\u9700\u6c42\uff0c\u53ef<b class=\"bold-spec\">\u72ec\u7acb\u52a0\u88c5\u5730\u6696<\/b>\uff08\u6c34\u5730\u6696\/\u7535\u5730\u6696\uff09\uff0c\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u7ba1\u9053\u5b8c\u5168\u72ec\u7acb\u3001\u4e92\u4e0d\u5e72\u6270\u3002<\/p>\n      <\/div>\n\n      <div class=\"section-tabs\">\n        <span class=\"section-tab active\" data-section=\"s2\" data-card=\"0\">\u8bbe\u8ba1\u539f\u5219<\/span>\n        <span class=\"section-tab\" data-section=\"s2\" data-card=\"1\">\u9010\u623f\u95f4\u8d1f\u8377\u6d4b\u7b97<\/span>\n        <span class=\"section-tab\" data-section=\"s2\" data-card=\"2\">\u4e3a\u4ec0\u4e48\u9009\u8212\u4eab160<\/span>\n        <span class=\"section-tab\" data-section=\"s2\" data-card=\"3\">\u8bbe\u8ba1\u4f9d\u636e<\/span>\n      <\/div>\n\n      <div class=\"slider-container\">\n      <div class=\"content-card slider-card active\">\n        <h3 class=\"card-title\">\u8bbe\u8ba1\u539f\u5219<\/h3>\n        <details class=\"step-card\"><summary>1. \u9010\u623f\u95f4\u51b7\u8d1f\u8377\u6d4b\u7b97 \u2014 \u4e0d\u62cd\u8111\u888b\u9760\u6570\u636e<\/summary><p>\u4f9d\u636eGB 50736-2012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b\uff0c\u6309\u6bcf\u4e2a\u623f\u95f4\u7684\u9762\u79ef\u3001\u671d\u5411\u3001\u5916\u5899\/\u5916\u7a97\u6761\u4ef6\u3001\u4f7f\u7528\u529f\u80fd\u5206\u522b\u8ba1\u7b97\u51b7\u8d1f\u8377\u3002103.87\u33a1\u5e73\u5c42\u62c6\u5206\u4e3a4\u4e2a\u533a\u57df\uff0c\u624d\u80fd\u786e\u5b9a\u5185\u673a\u5bb9\u91cf\u3002<\/p><\/details>\n        <details class=\"step-card\"><summary>2. \u5927\u516c\u533a\u91cd\u70b9\u4fdd\u969c \u2014 \u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1<\/summary><p>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u662f\u672c\u6848\u6700\u5927\u5355\u4e00\u7a7a\u8c03\u533a\u57df\uff0c\u4eba\u5458\u6d3b\u52a8\u9891\u7e41\u3002\u914d\u7f6eRPIZ-50\uff085000W\uff09+ RPIZ-22\uff082200W\uff09\u4e24\u53f0\u5185\u673a\uff0c\u5408\u8ba17200W\uff0c\u65e2\u4fdd\u8bc1\u5feb\u901f\u964d\u6e29\uff0c\u53c8\u53ef\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002<\/p><\/details>\n        <details class=\"step-card\"><summary>3. \u5bb6\u5ead\u5ba4\u5355\u72ec\u5927\u5185\u673a \u2014 30.9\u33a1\u914d63\u5185\u673a<\/summary><p>\u5bb6\u5ead\u5ba430.9\u33a1\u4f5c\u4e3a\u72ec\u7acb\u5927\u7a7a\u95f4\uff0c\u5355\u53f0RPIZ-63\uff086300W\uff09\u96c6\u4e2d\u9001\u51b7\uff0c\u5b9e\u9645\u51b7\u6307\u6807204W\/\u33a1\uff0c\u6ee1\u8db3\u5927\u7a7a\u95f4\u5236\u51b7\u9700\u6c42\u3002<\/p><\/details>\n        <details class=\"step-card\"><summary>4. \u5367\u5ba4\u6309\u9762\u79ef\u5206\u7ea7\u914d\u7f6e<\/summary><p>\u4e3b\u536715.3\u33a1\u3001\u6b21\u536714.27\u33a1\u5747\u914d\u7f6eRPIZ-25\uff082500W\uff09\uff0c\u5b9e\u9645\u51b7\u6307\u6807\u5206\u522b\u4e3a163W\/\u33a1\u3001175W\/\u33a1\uff0c\u6309\u5b9e\u9645\u8d1f\u8377\u7cbe\u51c6\u9009\u578b\u3002<\/p><\/details>\n        <details class=\"step-card\"><summary>5. \u8fde\u63a5\u7387\u5408\u7406\u63a7\u5236 \u2014 119.4%<\/summary><p>5\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W \/ \u5916\u673a\u5bb9\u91cf15500W = \u8fde\u63a5\u7387119.4%\u3002\u8fd9\u4e2a\u6bd4\u4f8b\u5728\u884c\u4e1a\u5185\u5c5e\u4e8e<b class=\"bold-spec\">\u7ecf\u6d4e\u9ad8\u6548\u533a\u95f4<\/b>\uff1a\u4fdd\u8bc1\u5168\u5c4b5\u53f0\u540c\u65f6\u5f00\u542f\u65f6\u5236\u51b7\u91cf\u5145\u8db3\uff0c\u5916\u673aAPF 5.80\u9ad8\u80fd\u6548\uff0c\u90e8\u5206\u8d1f\u8377\u8fd0\u884c\u65f6\u66f4\u7701\u7535\u3002<\/p><\/details>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u9010\u623f\u95f4\u51b7\u8d1f\u8377\u6d4b\u7b97 \u00b7 \u53ef\u89c6\u5316<\/h3>\n\n        <div class=\"load-summary\">\n          <div class=\"ls-card\"><span class=\"ls-num\">103.87<\/span><span class=\"ls-lbl\">\u7a7a\u8c03\u9762\u79ef \u33a1<\/span><\/div>\n          <div class=\"ls-card\"><span class=\"ls-num\">5<\/span><span class=\"ls-lbl\">\u5185\u673a\u53f0\u6570<\/span><\/div>\n          <div class=\"ls-card\"><span class=\"ls-num\">18500<\/span><span class=\"ls-lbl\">\u603b\u8bbe\u5907\u5bb9\u91cf W<\/span><\/div>\n          <div class=\"ls-card\"><span class=\"ls-num\">119.4%<\/span><span class=\"ls-lbl\">\u8fde\u63a5\u7387<\/span><\/div>\n        <\/div>\n\n        <div class=\"room-chart\">\n          <div class=\"chart-header\">\n            <span>\u623f\u95f4 \/ \u9762\u79ef<\/span>\n            <span>\u5185\u673a\u578b\u53f7<\/span>\n            <span>\u5b9e\u9645\u51b7\u6307\u6807 vs \u8bbe\u8ba1\u57fa\u51c6 150W\/\u33a1<\/span>\n            <span style=\"text-align:right\">\u5bb9\u91cf<\/span>\n          <\/div>\n\n          <div class=\"room-row\">\n            <div class=\"room-meta\">\n              <div class=\"room-name\">\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f<\/div>\n              <span class=\"room-area\">43.4 \u33a1<\/span>\n            <\/div>\n            <div class=\"room-model\">RPIZ-50 + RPIZ-22<\/div>\n            <div class=\"room-meter\">\n              <div class=\"meter-track\">\n                <div class=\"meter-design\" style=\"left:60%\"><\/div>\n                <div class=\"meter-actual\" style=\"width:66.4%\" data-val=\"166\"><\/div>\n              <\/div>\n              <div class=\"meter-labels\">\n                <span class=\"actual\">\u5b9e\u9645 166 W\/\u33a1<\/span>\n                <span class=\"design\">\u8bbe\u8ba1\u57fa\u51c6 150 W\/\u33a1<\/span>\n              <\/div>\n            <\/div>\n            <div class=\"room-cap\">7200 W<\/div>\n          <\/div>\n\n          <div class=\"room-row\">\n            <div class=\"room-meta\">\n              <div class=\"room-name\">\u5bb6\u5ead\u5ba4<\/div>\n              <span class=\"room-area\">30.9 \u33a1<\/span>\n            <\/div>\n            <div class=\"room-model\">RPIZ-63<\/div>\n            <div class=\"room-meter\">\n              <div class=\"meter-track\">\n                <div class=\"meter-design\" style=\"left:60%\"><\/div>\n                <div class=\"meter-actual\" style=\"width:81.6%\" data-val=\"204\"><\/div>\n              <\/div>\n              <div class=\"meter-labels\">\n                <span class=\"actual\">\u5b9e\u9645 204 W\/\u33a1<\/span>\n                <span class=\"design\">\u8bbe\u8ba1\u57fa\u51c6 150 W\/\u33a1<\/span>\n              <\/div>\n            <\/div>\n            <div class=\"room-cap\">6300 W<\/div>\n          <\/div>\n\n          <div class=\"room-row\">\n            <div class=\"room-meta\">\n              <div class=\"room-name\">\u4e3b\u5367<\/div>\n              <span class=\"room-area\">15.3 \u33a1<\/span>\n            <\/div>\n            <div class=\"room-model\">RPIZ-25<\/div>\n            <div class=\"room-meter\">\n              <div class=\"meter-track\">\n                <div class=\"meter-design\" style=\"left:60%\"><\/div>\n                <div class=\"meter-actual\" style=\"width:65.2%\" data-val=\"163\"><\/div>\n              <\/div>\n              <div class=\"meter-labels\">\n                <span class=\"actual\">\u5b9e\u9645 163 W\/\u33a1<\/span>\n                <span class=\"design\">\u8bbe\u8ba1\u57fa\u51c6 150 W\/\u33a1<\/span>\n              <\/div>\n            <\/div>\n            <div class=\"room-cap\">2500 W<\/div>\n          <\/div>\n\n          <div class=\"room-row\">\n            <div class=\"room-meta\">\n              <div class=\"room-name\">\u6b21\u5367<\/div>\n              <span class=\"room-area\">14.27 \u33a1<\/span>\n            <\/div>\n            <div class=\"room-model\">RPIZ-25<\/div>\n            <div class=\"room-meter\">\n              <div class=\"meter-track\">\n                <div class=\"meter-design\" style=\"left:60%\"><\/div>\n                <div class=\"meter-actual\" style=\"width:70.0%\" data-val=\"175\"><\/div>\n              <\/div>\n              <div class=\"meter-labels\">\n                <span class=\"actual\">\u5b9e\u9645 175 W\/\u33a1<\/span>\n                <span class=\"design\">\u8bbe\u8ba1\u57fa\u51c6 150 W\/\u33a1<\/span>\n              <\/div>\n            <\/div>\n            <div class=\"room-cap\">2500 W<\/div>\n          <\/div>\n        <\/div>\n        <p class=\"chart-note\">\u8bbe\u5907\u5c3a\u5bf8\uff1aRPIZ-50 192\u00d7910\u00d7447mm\uff5cRPIZ-22 192\u00d7550\u00d7447mm\uff5cRPIZ-63 192\u00d71180\u00d7447mm\uff5cRPIZ-25 192\u00d7550\u00d7447mm<\/p>\n        <div class=\"param-card\" style=\"margin-top:16px\">\n          <div class=\"param-title\">\u5ba4\u5916\u673a\u53c2\u6570\uff08RAS-160HRNAQ \u8212\u4eab160 \u5355\u98ce\u6247\uff09<\/div>\n          <div class=\"param-row\">\n            <div class=\"param-item\"><div class=\"pval\">RAS-160HRNAQ<\/div><div class=\"plbl\">\u5916\u673a\u578b\u53f7<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">15500W<\/div><div class=\"plbl\">\u989d\u5b9a\u5236\u51b7\u91cf<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">17000W<\/div><div class=\"plbl\">\u989d\u5b9a\u5236\u70ed\u91cf<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">119.4%<\/div><div class=\"plbl\">\u8fde\u63a5\u7387<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">APF 5.80<\/div><div class=\"plbl\">\u80fd\u6548\u6307\u6807<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">54dB(A)<\/div><div class=\"plbl\">\u566a\u97f3\u503c<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">770\u00d7980\u00d7360<\/div><div class=\"plbl\">\u8bbe\u5907\u5c3a\u5bf8(mm)<\/div><\/div>\n            <div class=\"param-item\"><div class=\"pval\">\u53cc\u8f6c\u5b50<\/div><div class=\"plbl\">\u538b\u7f29\u673a\u7c7b\u578b<\/div><\/div>\n          <\/div>\n          <p style=\"margin-top:10px;color:var(--text-gray);font-size:0.83rem\">\u8fd0\u8f6c\u8303\u56f4\uff1a\u5236\u51b7-5~59\u2103 \/ \u5236\u70ed-23~17\u2103 | \u7535\u6e90\uff1a220V | \u8fde\u63a5\u7ba1\uff1a\u6807\u51c6\u914d\u7f6e | \u51c0\u5316\/\u6392\u6c34\/\u81a8\u80c0\/\u68ee\u6797\u98ce\/\u9664\u6e7f\/3P\/E\u6a21\u5f0f\uff1a\u5168\u90e8\u5177\u5907 \u2713<\/p>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u4e3a\u4ec0\u4e48\u9009\u65e5\u7acb\u8212\u4eab160\uff1f<\/h3>\n        <div class=\"info-block\">\n          <div class=\"info-block-h\">\u2744\ufe0f \u8212\u4eab160 \u2014 \u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u4e3b\u529b\u673a\u578b<\/div>\n          <p style=\"font-size:0.88rem;line-height:1.6\"><b class=\"bold-spec\">RAS-160HRNAQ<\/b>\u662f\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u7684\u5355\u98ce\u6247\u5916\u673a\uff0c\u4e13\u4e3a100~120\u33a1\u5e73\u5c42\u6237\u578b\u8bbe\u8ba1\u3002<b class=\"bold-spec\">\u6838\u5fc3\u4f18\u52bf\uff1a<\/b><\/p>\n          <ul style=\"font-size:0.86rem;line-height:1.8;margin:10px 0 0 20px\">\n            <li><b>APF 5.80<\/b>\uff1a\u65b0\u56fd\u6807\u4e00\u7ea7\u80fd\u6548\uff0c\u957f\u671f\u4f7f\u7528\u7535\u8d39\u53ef\u63a7\uff0c\u5951\u5408\"\u4e0d\u8d39\u7535\"\u8bc9\u6c42<\/li>\n            <li><b>\u8fde\u63a5\u7387119.4%<\/b>\uff1a5\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W\u5339\u914d15500W\u5916\u673a\uff0c\u9884\u7559\u5168\u5c4b\u540c\u5f00\u4f59\u91cf<\/li>\n            <li><b>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/b>\uff1a\u8fd0\u884c\u66f4\u5e73\u7a33\u3001\u566a\u97f3\u66f4\u4f4e\uff08\u4ec554dB(A)\uff09\uff0c\u5951\u5408\"\u9759\u97f3\"\u8bc9\u6c42<\/li>\n            <li><b>-5~59\u2103\u5bbd\u6e29\u57df<\/b>\uff1a\u6210\u90fd\u9177\u669138\u2103\u4ee5\u4e0a\u4f9d\u7136\u5f3a\u52b2\u5236\u51b7\uff0c\u5951\u5408\"\u5236\u51b7\u5feb\"\u8bc9\u6c42<\/li>\n            <li><b>\u4e00\u62d6\u4e94\u5168\u8986\u76d6<\/b>\uff1a\u5b8c\u7f8e\u9002\u914d\u5e73\u5c42\u56db\u533a\u57df\u683c\u5c40\uff0c\u6bcf\u5ba4\u72ec\u7acb\u63a7\u6e29<\/li>\n            <li><b>\u914d\u7f6e\u5355\u900f\u660e<\/b>\uff1a\u8521\u8001\u5e08\u53ef\u9010\u9879\u6838\u5bf9\u9762\u79ef\u3001\u51b7\u6307\u6807\u3001\u578b\u53f7\uff0c\u51b3\u7b56\u6709\u4f9d\u636e<\/li>\n          <\/ul>\n        <\/div>\n        <div class=\"info-block\">\n          <div class=\"info-block-h\">\ud83d\udd04 \u4e0e\u5176\u4ed6\u65b9\u6848\u7684\u5bf9\u6bd4<\/div>\n          <p style=\"font-size:0.88rem;line-height:1.6\">\u5bf9\u4e8e\u8521\u8001\u5e08\u5bb6\u5e73\u5c42103.87\u33a1\u7684\u9700\u6c42\uff1a<b class=\"bold-spec\">\u98ce\u7ba1\u673a\u4e00\u62d6\u4e00<\/b>\u9700\u89815\u53f0\u5916\u673a\u5360\u6ee1\u8bbe\u5907\u5e73\u53f0\u4e14\u603b\u6210\u672c\u66f4\u9ad8\uff1b<b class=\"bold-spec\">\u67dc\u673a+\u6302\u673a\u7ec4\u5408<\/b>\u5360\u7528\u5730\u9762\u7a7a\u95f4\u3001\u7f8e\u89c2\u5ea6\u5dee\u4e14\u5404\u623f\u95f4\u6e29\u5dee\u5927\uff1b<b class=\"bold-spec\">\u5176\u4ed6\u54c1\u724c120\/140\u673a\u578b<\/b>\u5728APF\u80fd\u6548\u548c\u566a\u97f3\u63a7\u5236\u4e0a\u7565\u900a\u4e00\u7b79\uff1b<b class=\"bold-spec\">\u8212\u4eab160\u4e00\u62d6\u4e94<\/b>\u4ec5\u9700\u4e00\u53f0\u5916\u673a\u3001\u9690\u85cf\u5f0f\u5b89\u88c5\u7f8e\u89c2\u5927\u65b9\u3001\u5404\u5ba4\u72ec\u7acb\u63a7\u6e29\u3001\u603b\u6295\u5165\u6027\u4ef7\u6bd4\u6700\u4f18\u2014\u2014\u8fd9\u662f\u672c\u5e73\u5c42\u6237\u578b\u7684\u6700\u4f73\u9009\u62e9\u3002<\/p>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u8bbe\u8ba1\u4f9d\u636e<\/h3>\n        <div style=\"display:flex;gap:16px;flex-wrap:wrap;margin-top:8px\">\n          <span class=\"tag\"><b class=\"bold-spec\">GB 50736-2012<\/b> \u56fd\u6807<\/span><span class=\"tag\">\u73b0\u573a\u52d8\u6d4b\u6570\u636e<\/span><span class=\"tag gold\">\u6210\u90fd\u5e73\u5c42\u6570\u636e\u5e93<\/span>\n        <\/div>\n        <p style=\"margin-top:14px\">\u4f9d\u636e<b class=\"bold-spec\">\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB 50736-2012<\/b>\uff0c\u7ed3\u5408\u73b0\u573a\u52d8\u6d4b\uff08\u5e73\u5c42103.87\u33a1\u3001\u73b0\u4ee3\u5efa\u7b51\u4fdd\u6e29\u826f\u597d\u3001\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u4e0e\u5bb6\u5ead\u5ba4\u4e3a\u5927\u516c\u533a\uff09\u8fdb\u884c\u9010\u623f\u95f4\u51b7\u8d1f\u8377\u6d4b\u7b97\u3002\u8bbe\u8ba1\u51b7\u6307\u6807\u7edf\u4e00\u91c7\u7528<b class=\"bold-spec\">150W\/\u33a1<\/b>\uff08\u9ad8\u5c42\/\u5c0f\u9ad8\u5c42\u4f4f\u5b85\u5e38\u89c4\u503c\uff09\uff0c\u5b9e\u9645\u51b7\u6307\u6807\u56e0\u623f\u95f4\u9762\u79ef\u53d6\u6574\u7565\u6709\u6d6e\u52a8\uff08163~204W\/\u33a1\uff09\uff0c\u603b\u5236\u51b7\u91cf<b class=\"bold-spec\">18500W<\/b>\uff0c\u5916\u673a\u9009\u7528RAS-160HRNAQ\uff08\u989d\u5b9a\u5236\u51b7\u91cf15500W\uff09\u3002\u53c2\u8003\u9f99\u8109\u6696\u901a\u6210\u90fd\u672c\u5730\u6848\u4f8b\u6570\u636e\u5e93\u4e2d\u540c\u7c7b\u5e73\u5c42\u6237\u578b\u7684\u914d\u7f6e\u7ecf\u9a8c\u8fdb\u884c\u4f18\u5316\u3002<\/p>\n      <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"step-section\" id=\"s3\">\n    <input type=\"checkbox\" id=\"fold-s3\" class=\"fold-cb\">\n    <label for=\"fold-s3\" class=\"fold-lbl\"><h2 class=\"step-head\">S3 \u00b7 \u5b8c\u6574\u8bbe\u5907\u914d\u7f6e\u6e05\u5355 &amp; \u65b9\u6848\u5bf9\u6bd4<span class=\"fold-ico\">\u25be \u5c55\u5f00\/\u6536\u8d77<\/span><\/h2><\/label>\n    <div class=\"fold-body\">\n      <div class=\"section-tabs\">\n        <span class=\"section-tab active\" data-section=\"s3\" data-card=\"0\">\u65b9\u6848\u914d\u7f6e<\/span>\n        <span class=\"section-tab\" data-section=\"s3\" data-card=\"1\">\u4e00\u62d6\u4e94vs\u5176\u4ed6\u65b9\u6848\u5bf9\u6bd4<\/span>\n        <span class=\"section-tab\" data-section=\"s3\" data-card=\"2\">\u900f\u660e\u8bf4\u660e<\/span>\n      <\/div>\n\n      <div class=\"slider-container\">\n      <div class=\"content-card slider-card active\">\n        <div class=\"flip-back\" style=\"transform:none;backface-visibility:visible;position:static\">\n          <h3 class=\"card-title\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8212\u4eab160\u65b9\u6848\u914d\u7f6e<\/h3>\n          <table class=\"info-table\">\n            <tbody><tr><th>\u5b50\u7cfb\u7edf<\/th><th>\u9009\u7528\u8bbe\u5907 \/ \u6750\u6599<\/th><th>\u5173\u952e\u53c2\u6570<\/th><th>\u6570\u91cf<\/th><\/tr>\n              <tr><td>\u4e2d\u592e\u7a7a\u8c03\u5916\u673a<\/td><td>\u65e5\u7acb \u8212\u4eab160 <b class=\"bold-spec\">RAS-160HRNAQ<\/b><\/td><td>\u989d\u5b9a\u5236\u51b715500W\/\u5236\u70ed17000W\uff0cAPF 5.80\uff0c\u5355\u98ce\u6247\uff0c54dB(A)\uff0c770\u00d7980\u00d7360mm<\/td><td>1\u53f0<\/td><\/tr>\n              <tr><td>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u5185\u673a\u2460<\/td><td>\u65e5\u7acb <b class=\"bold-spec\">RPIZ-50FSNAQD\/P<\/b><\/td><td>5000W\uff0c192\u00d7910\u00d7447mm\uff0c\u670d\u52a143.4\u33a1\u5927\u516c\u533a<\/td><td>1\u53f0<\/td><\/tr>\n              <tr><td>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u5185\u673a\u2461<\/td><td>\u65e5\u7acb <b class=\"bold-spec\">RPIZ-22FSNAQD\/P<\/b><\/td><td>2200W\uff0c192\u00d7550\u00d7447mm\uff0c\u670d\u52a143.4\u33a1\u5927\u516c\u533a<\/td><td>1\u53f0<\/td><\/tr>\n              <tr><td>\u5bb6\u5ead\u5ba4\u5185\u673a<\/td><td>\u65e5\u7acb <b class=\"bold-spec\">RPIZ-63FSNAQD\/P<\/b><\/td><td>6300W\uff0c192\u00d71180\u00d7447mm\uff0c\u670d\u52a130.9\u33a1\u5bb6\u5ead\u5ba4<\/td><td>1\u53f0<\/td><\/tr>\n              <tr><td>\u4e3b\u5367\u5185\u673a<\/td><td>\u65e5\u7acb <b class=\"bold-spec\">RPIZ-25FSNAQD\/P<\/b><\/td><td>2500W\uff0c192\u00d7550\u00d7447mm\uff0c\u5b9e\u9645\u51b7\u6307\u6807163W\/\u33a1<\/td><td>1\u53f0<\/td><\/tr>\n              <tr><td>\u6b21\u5367\u5185\u673a<\/td><td>\u65e5\u7acb <b class=\"bold-spec\">RPIZ-25FSNAQD\/P<\/b><\/td><td>2500W\uff0c192\u00d7550\u00d7447mm\uff0c\u5b9e\u9645\u51b7\u6307\u6807175W\/\u33a1<\/td><td>1\u53f0<\/td><\/tr>\n              <tr><td>\u7ebf\u63a7\u5668<\/td><td>\u65e5\u7acb \u8212\u4eab\u7a7a\u8c03\u7ebf\u63a7\u5668<\/td><td>\u6bcf\u53f0\u5185\u673a\u72ec\u7acb\u63a7\u5236<\/td><td>5\u4e2a<\/td><\/tr>\n            <\/tbody><\/table>\n          <div class=\"param-card\">\n            <div class=\"param-title\">\u5173\u952e\u53c2\u6570\u901f\u89c8<\/div>\n            <div class=\"param-row\">\n              <div class=\"param-item\"><div class=\"pval\">RAS-160HRNAQ<\/div><div class=\"plbl\">\u5916\u673a\u578b\u53f7<\/div><\/div>\n              <div class=\"param-item\"><div class=\"pval\">18500W<\/div><div class=\"plbl\">\u603b\u5236\u51b7\u91cf<\/div><\/div>\n              <div class=\"param-item\"><div class=\"pval\">119.4%<\/div><div class=\"plbl\">\u8fde\u63a5\u7387<\/div><\/div>\n              <div class=\"param-item\"><div class=\"pval\">APF 5.80<\/div><div class=\"plbl\">\u80fd\u6548\u7b49\u7ea7<\/div><\/div>\n              <div class=\"param-item\"><div class=\"pval\">54dB(A)<\/div><div class=\"plbl\">\u5916\u673a\u566a\u97f3<\/div><\/div>\n              <div class=\"param-item\"><div class=\"pval\">\u4e00\u62d6\u4e94<\/div><div class=\"plbl\">\u5185\u673a\u6570\u91cf<\/div><\/div>\n            <\/div>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u4e00\u62d6\u4e94 vs \u5176\u4ed6\u65b9\u6848 \u00b7 \u76f4\u89c2\u5bf9\u6bd4<\/h3>\n        <table style=\"width:100%;border-collapse:collapse;font-size:0.82rem;line-height:1.4;background:#fff;border-radius:10px;overflow:hidden;box-shadow:0 1px 5px rgba(20,82,163,0.08)\">\n          <thead>\n            <tr>\n              <th style=\"width:20%;padding:11px 9px;text-align:left;background:#f4f6f9;color:#445;font-weight:700;border-bottom:2px solid #dde3ea\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n              <th style=\"width:27%;padding:11px 9px;text-align:center;background:#E6F1FB;color:#1452a3;font-weight:800;border-bottom:3px solid #1a6fd0;border-left:4px solid #1a6fd0\">\n                <span style=\"display:inline-block;background:#1a6fd0;color:#fff;font-size:0.68rem;padding:2px 9px;border-radius:10px;margin-bottom:5px\">\u2605 \u63a8\u8350\u65b9\u6848<\/span><br>\u672c\u65b9\u6848<br>\u8212\u4eab160\u4e00\u62d6\u4e94\n              <\/th>\n              <th style=\"width:26%;padding:11px 9px;text-align:center;background:#fafbfc;color:#556;font-weight:700;border-bottom:2px solid #dde3ea\">\u683c\u529b\/\u7f8e\u7684 160\u4e00\u62d6\u4e94<\/th>\n              <th style=\"width:27%;padding:11px 9px;text-align:center;background:#fafbfc;color:#556;font-weight:700;border-bottom:2px solid #dde3ea\">\u98ce\u7ba1\u673a\u4e00\u62d6\u4e00\u00d75<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u5916\u673a\u6570\u91cf<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">\u4ec5 1 \u53f0 <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">1 \u53f0<\/td>\n              <td style=\"padding:9px;text-align:center;color:#c0392b\">5 \u53f0 <span style=\"display:inline-block;background:#fdecea;color:#c0392b;font-size:0.66rem;padding:1px 6px;border-radius:8px;margin-left:3px\">\u6324\u5360\u7a7a\u95f4<\/span><\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">APF\u80fd\u6548<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">5.80 \u00b7 \u4e00\u7ea7\u80fd\u6548\n                <div style=\"margin-top:5px;height:7px;background:#cfe2f7;border-radius:4px;overflow:hidden\"><div style=\"height:100%;width:96%;background:linear-gradient(90deg,#1a6fd0,#3aa0ff)\"><\/div><\/div>\n                <div style=\"font-size:0.66rem;color:#1aa33a;margin-top:2px;font-weight:700\">\u9886\u5148\u540c\u7ea7 \u2713<\/div>\n              <\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u7ea6 4.8~5.2\n                <div style=\"margin-top:5px;height:7px;background:#eee;border-radius:4px;overflow:hidden\"><div style=\"height:100%;width:85%;background:#aab2bd\"><\/div><\/div>\n              <\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u53c2\u5dee\u4e0d\u9f50\n                <div style=\"margin-top:5px;height:7px;background:#eee;border-radius:4px;overflow:hidden\"><div style=\"height:100%;width:50%;background:#c3c9d1\"><\/div><\/div>\n              <\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u5916\u673a\u566a\u97f3<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">54dB(A) \u8f83\u4f4e <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u7ea656~58dB(A)<\/td>\n              <td style=\"padding:9px;text-align:center;color:#c0392b\">\u591a\u53f0\u53e0\u52a0\u66f4\u9ad8<\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u7f8e\u89c2\u5ea6<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">\u5168\u9690\u85cf\u540a\u9876 <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u5168\u9690\u85cf\u540a\u9876<\/td>\n              <td style=\"padding:9px;text-align:center;color:#c0392b\">\u591a\u5904\u9884\u7559\u68c0\u4fee\u53e3<\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u521d\u6295\u8d44<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">\u6027\u4ef7\u6bd4\u6700\u4f18 <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u7565\u4f4e<\/td>\n              <td style=\"padding:9px;text-align:center;color:#c0392b\">\u8f83\u9ad8\uff085\u5957\u72ec\u7acb\uff09<\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u8fd0\u884c\u8d39\u7528<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">APF 5.80 \u7701\u7535 <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u80fd\u8017\u504f\u9ad8<\/td>\n              <td style=\"padding:9px;text-align:center;color:#c0392b\">\u591a\u53f0\u5c0f\u5916\u673a\u6548\u7387\u4f4e<\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u63a7\u6e29\u7cbe\u5ea6<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">\u5206\u5ba4 \u00b11\u2103\n                <span style=\"display:inline-block;background:#e3f1e8;color:#1aa33a;font-size:0.66rem;padding:1px 7px;border-radius:8px;border:1px solid #b6e0c2;margin-top:3px\">\u7cbe\u51c6<\/span>\n              <\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u5206\u5ba4\u6e29\u63a7<\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u5404\u81ea\u72ec\u7acb\u63a7\u5236<\/td>\n            <\/tr>\n            <tr style=\"border-bottom:1px solid #eef1f5\">\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u5168\u5c4b\u540c\u5f00<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">18500W \u5145\u8db3 <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u5145\u8db3<\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u5145\u8db3\u4f46\u5916\u673a\u591a<\/td>\n            <\/tr>\n            <tr>\n              <td style=\"padding:9px;text-align:left;background:#f7f9fc;color:#334;font-weight:600\">\u9002\u7528\u6237\u578b<\/td>\n              <td style=\"padding:9px;text-align:center;background:#E6F1FB;border-left:4px solid #1a6fd0;color:#1a3a6e;font-weight:700\">\u5e73\u5c42100~120\u33a1 <span style=\"color:#1aa33a;font-weight:800\">\u2713<\/span><\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u9884\u7b97\u654f\u611f\u578b<\/td>\n              <td style=\"padding:9px;text-align:center;color:#556\">\u5404\u623f\u95f4\u9700\u6c42\u72ec\u7acb<\/td>\n            <\/tr>\n          <\/tbody>\n        <\/table>\n        <div style=\"margin-top:14px;background:linear-gradient(135deg,#E6F1FB,#f3f9ff);border:1px solid #cfe2f7;border-radius:10px;padding:13px 16px\">\n          <div style=\"font-weight:800;color:#1452a3;margin-bottom:5px;font-size:0.9rem\">\ud83d\udca1 \u4e3a\u4ec0\u4e48\u63a8\u8350\u8212\u4eab160\u4e00\u62d6\u4e94\uff1f<\/div>\n          <div style=\"font-size:0.82rem;color:#2c3e50;line-height:1.65\">\u5e73\u5c42103.87\u33a1\u3001\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u4e0e\u5bb6\u5ead\u5ba4\u4e24\u5927\u516c\u533a\u5408\u8ba174.3\u33a1\u3001\u4ee5\u5236\u51b7\u4e3a\u4e3b\u7684\u4f7f\u7528\u573a\u666f\u4e0b\uff0c\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u5728<strong>\u5236\u51b7\u6548\u679c\u3001\u8fd0\u884c\u7a33\u5b9a\u3001\u6295\u5165\u6027\u4ef7\u6bd4<\/strong>\u4e09\u8005\u95f4\u53d6\u5f97\u6700\u4f73\u5e73\u8861\uff1a\u5355\u5916\u673a\u4e0d\u6324\u5360\u8bbe\u5907\u5e73\u53f0\u3001APF 5.80\u4e00\u7ea7\u80fd\u6548\u957f\u671f\u7701\u7535\u30015\u53f0\u5185\u673a\u5206\u5ba4\u6e29\u63a7\u7cbe\u51c6\u8212\u9002\uff0c\u4e14\u8fde\u63a5\u7387119.4%\u9884\u7559\u4e86\u5168\u5c4b\u540c\u5f00\u4f59\u91cf\u3002<\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u5168\u5957\u8bbe\u5907 + \u8f85\u6750\u660e\u7ec6\u6e05\u5355<\/h3>\n        <p style=\"font-size:0.82rem;color:var(--text-gray);margin:2px 0 8px\">\u6309\u9f99\u8109\u6696\u901a\u300a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u00b7 \u9644\u8868A \u7eaf\u6c1f\u4e2d\u592e\u7a7a\u8c03\u300b\uff08\u8212\u4eab\u7cfb\u5217\u9002\u7528\uff09\u6807\u51c6\u5217\u793a\uff1b\u8f85\u6750\u4ec5\u5217\u54c1\u724c \/ \u89c4\u683c \/ \u529f\u80fd\uff0c\u4e0d\u6d89\u53ca\u62a5\u4ef7\u91d1\u989d\uff0c\u9ed8\u8ba4\u89c4\u683c\u4e00\u5f8b\u6309\u6807\u51c6\u8f93\u51fa\u3002<\/p>\n        <table class=\"info-table\">\n          <tbody><tr><th>\u7c7b\u522b<\/th><th>\u54c1\u724c<\/th><th>\u540d\u79f0 \/ \u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n            <tr><td>\u4e3b\u673a\u8bbe\u5907<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab160 RAS-160HRNAQ \u5916\u673a<\/td><td>1\u53f0<\/td><td>\u5236\u51b715500W \/ \u5236\u70ed17000W\uff0cAPF 5.80\uff0c54dB(A)<\/td><\/tr>\n            <tr><td>\u4e3b\u673a\u8bbe\u5907<\/td><td>\u65e5\u7acb<\/td><td>RPIZ-50\/22\/63\/25\/25 FSNAQD\/P \u5185\u673a<\/td><td>5\u53f0<\/td><td>5000\/2200\/6300\/2500\/2500W\uff0c\u8d85\u8584192mm\u673a\u8eab<\/td><\/tr>\n            <tr><td>\u4e3b\u673a\u8bbe\u5907<\/td><td>\u65e5\u7acb<\/td><td>\u8212\u4eab\u7a7a\u8c03\u7ebf\u63a7\u5668<\/td><td>5\u4e2a<\/td><td>\u6bcf\u53f0\u5185\u673a\u72ec\u7acb\u63a7\u5236\uff0c\u9ad8\u6e05\u80cc\u5149<\/td><\/tr>\n            <tr><td colspan=\"5\" style=\"background:#f6f2e7;font-weight:600;color:#7a6334\">\u4e00\u3001\u7a7a\u8c03\u98ce\u7cfb\u7edf\u90e8\u5206<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c\uff09<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6\uff08\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6\uff09<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5b9a\u5236<\/td><td>\u8f85\u6750\uff08\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49\uff09<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr>\n            <tr><td colspan=\"5\" style=\"background:#f6f2e7;font-weight:600;color:#7a6334\">\u4e8c\u3001\u7ba1\u8def\u7cfb\u7edf\u53ca\u8f85\u6599\u90e8\u5206<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1 6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1 15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5bf9\u51b7\u5a92\u8fdb\u884c\u5206\u914d<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92 R410A\u65b0\u51b7\u5a92<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1 De25<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n            <tr><td colspan=\"5\" style=\"background:#f6f2e7;font-weight:600;color:#7a6334\">\u4e09\u3001\u4fdd\u6e29\u53ca\u540a\u67b6\u90e8\u5206<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4) \u539a\u5ea620mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4) \u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u540a\u5361 \u9540\u950c\u4e0d\u9508\u94a2\u540a\u5361\uff08\u914d\u62b1\u7b8d\uff09<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u7ba1\u8def\u5b89\u88c5\uff0c\u5347\u7ea7\u5de5\u827a<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6750\uff08\u4e1d\u6760\u3001\u81a8\u80c0\u3001\u51cf\u9707\u57ab\u7b49\uff09<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u5b89\u88c5\u56fa\u5b9a<\/td><\/tr>\n            <tr><td colspan=\"5\" style=\"background:#f6f2e7;font-weight:600;color:#7a6334\">\u56db\u3001\u63a7\u5236\u7cfb\u7edf\u8f85\u6599\u53ca\u4eba\u5de5\u90e8\u5206<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf 1*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf 2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1 dn16<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u9f99\u8109<\/td><td>\u4eba\u5de5\uff08\u5f00\u5b54\/\u5b89\u88c5\u7b49\uff09<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\u7b49<\/td><\/tr>\n            <tr><td>\u8f85\u6750<\/td><td>\u9f99\u8109<\/td><td>\u8fd0\u8f93\u8d39<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u6750\u6599\u8fd0\u8f93<\/td><\/tr>\n          <\/tbody><\/table>\n        <div class=\"spec-notes\" style=\"margin-top:10px\">\n          <p style=\"font-weight:600;margin-bottom:4px\">\u8f85\u6750\u914d\u7f6e\u8bf4\u660e\uff08\u9f99\u8109\u6807\u51c6\u6761\u6b3e\uff09\uff1a<\/p>\n          <p>1\u3001\u542b\u8bbe\u5907\u5b89\u88c5\uff0c\u5899\u4f53\u5f00\u5b54\uff0c\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u8d39\u7528\u3002\u8bbe\u5907\u8d28\u4fdd\u671f\u4e3a\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u6574\u673a60\u4e2a\u6708\uff0c6\u4e2a\u6708\u4e3a\u88c5\u4fee\u671f\uff09\u3002<\/p>\n          <p>2\u3001\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u8f85\u6750\u6570\u91cf\u7684\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002<\/p>\n          <p>3\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3002<\/p>\n          <p>4\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u571f\u5efa\uff1b\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/p>\n          <p>5\u3001\u5982\u679c\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u8981\u52a8\u7528\u673a\u68b0\u8bbe\u5907\uff0c\u540a\u88c5\u8d39\u7528\u6839\u636e\u60c5\u51b5\u53e6\u8ba1\u3002<\/p>\n          <p>6\u3001\u5ba4\u5185\u673a\u9001\u3001\u56de\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7531\u7532\u65b9\u6728\u5de5\u5f00\u5b54\uff0c\u4e59\u65b9\u8d1f\u8d23\u63d0\u4f9b\u5f00\u5b54\u5c3a\u5bf8\u548c\u5b89\u88c5\uff0c\u98ce\u53e3\u91c7\u7528\u7edf\u4e00\u5c3a\u5bf8\u3002<\/p>\n          <p>7\u3001\u65b9\u6848\u6309\u7167\u4fa7\u51fa\u4e0b\u56de\u98ce\u8bbe\u8ba1\uff0c\u5982\u679c\u505a\u4e0b\u51fa\u98ce\uff0c\u6309150\u5143\/\u5e73\u65b9\u7c73\u6210\u54c1\u98ce\u7ba1\u53e6\u8ba1\u3002<\/p>\n          <p>8\u3001\u62a5\u4ef7\u98ce\u53e3\u6309\u7167\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u5982\u9700\u52a0\u957f\u6309150\u5143\/m\u53e6\u8ba1\uff0c\u4e0d\u8db3\u4e00\u7c73\u6309\u7167\u4e00\u7c73\u8ba1\u7b97\uff0c\u5916\u673a\u7ba1\u9053\u6263\u69fd\u6309100\u5143\/m\u53e6\u8ba1\u3002<\/p>\n          <p>9\u3001\u5efa\u8bae\u540a\u9876\u4e0d\u505a\u53cd\u5149\u706f\u69fd\uff0c\u53cd\u5149\u706f\u69fd\u5f71\u54cd\u5236\u51b7\u3001\u5236\u70ed\u6548\u679c\uff0c\u8dc3\u5c42\u548c\u5c42\u9ad8\u8d85\u8fc7\u4e09\u7c73\u5236\u70ed\u6548\u679c\u6b20\u4f73\u3002\u5982\u679c\u4fdd\u7559\u706f\u69fd\u8bbe\u8ba1\uff0c\u5efa\u8bae\u4f7f\u7528\u706f\u69fd\u4e13\u7528\u673a\u3002<\/p>\n          <p>10\u3001\u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a\u4e00\u4e2a\u6708\u3002\u5982\u6709\u9057\u6f0f\uff0c\u53cc\u65b9\u534f\u5546\u3002<\/p>\n        <\/div>\n\n        <h3 class=\"card-title\">\u900f\u660e\u8bf4\u660e<\/h3>\n        <div class=\"note-skeleton\">\ud83d\udccb <strong>\u65b9\u6848\u903b\u8f91\u8bf4\u660e<\/strong><br>\u672c\u65b9\u6848\u4ee5\"\u5236\u51b7\u5feb\u3001\u9759\u97f3\u3001\u4e0d\u8d39\u7535\"\u4e3a\u6838\u5fc3\u8bc9\u6c42\u2014\u2014\u5e73\u5c42103.87\u33a1\u3001\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u4e0e\u5bb6\u5ead\u5ba4\u4e24\u5927\u516c\u533a\u5408\u8ba174.3\u33a1\u7684\u4f7f\u7528\u573a\u666f\u4e0b\uff0c\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ\u4e00\u62d6\u4e94\u662f\u7ecf\u8fc7\u9010\u623f\u95f4\u51b7\u8d1f\u8377\u6d4b\u7b97\u540e\u7684\u63a8\u8350\u914d\u7f6e\u30025\u53f0\u5185\u673a\u6309\u5404\u623f\u95f4\u9762\u79ef\u4e0e\u671d\u5411\u7cbe\u51c6\u5339\u914d\uff08\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f 50+22\u51717200W + \u5bb6\u5ead\u5ba463 6300W + \u4e3b\u536725 2500W + \u6b21\u536725 2500W\uff09\uff0c\u8fde\u63a5\u7387119.4%\u4fdd\u8bc1\u5168\u5c4b5\u53f0\u540c\u65f6\u5f00\u542f\u65f6\u5236\u51b7\u91cf\u5145\u8db3\u3002<br><br>\ud83d\udcca <strong>\u5173\u4e8e\u8fde\u63a5\u7387<\/strong><br>\u2022 \u8fde\u63a5\u7387119.4%\u610f\u5473\u77405\u53f0\u5185\u673a\u5168\u5f00\u65f6\u7684\u603b\u5bb9\u91cf\u8d85\u8fc7\u5916\u673a\u5bb9\u91cf\u768419.4%<br>\u2022 \u5b9e\u9645\u4f7f\u7528\u4e2d\u5f88\u5c11\u51fa\u73b05\u53f0\u540c\u65f6\u6ee1\u8d1f\u8377\u8fd0\u884c\u7684\u60c5\u51b5\uff0c\u5927\u90e8\u5206\u65f6\u95f4\u90e8\u5206\u8d1f\u8377\u8fd0\u884c<br>\u2022 \u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5141\u8bb8\u7684\u8fde\u63a5\u7387\u4e0a\u9650\u901a\u5e38\u5728130%~150%\u4ee5\u5185\uff0c119.4%\u5904\u4e8e\u5b89\u5168\u4e14\u7ecf\u6d4e\u7684\u533a\u95f4<br>\u2022 \u767d\u5929\u53ea\u5f00\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\uff087200W\/15500W=46.5%\u8d1f\u8f7d\uff09\uff0c\u5916\u673a\u5728\u9ad8\u8d1f\u8f7d\u4e0b\u4e5f\u80fd\u7a33\u5b9a\u8f93\u51fa\uff1b\u665a\u4e0a\u53ea\u5f00\u5367\u5ba4\uff085000W\/15500W=32.3%\u8d1f\u8f7d\uff09\uff0c\u5916\u673a\u90e8\u5206\u8d1f\u8377\u6548\u7387\u6700\u9ad8\u3001\u6700\u7701\u7535<br><br>\ud83d\udcb0 <strong>\u5173\u4e8e\u4ef7\u683c<\/strong><br>\u2022 \u8212\u4eab160\u4e00\u62d6\u4e94\uff08\u5236\u51b7\u5236\u70ed\u517c\u987e\uff09\uff1a\u5177\u4f53\u9020\u4ef7\u56e0\u73b0\u573a\u6761\u4ef6\u3001\u8f85\u6750\u7528\u91cf\u800c\u5f02\uff0c\u4ee5\u6700\u7ec8\u51fa\u5177\u7684\u8be6\u7ec6\u65b9\u6848\u62a5\u4ef7\u4e3a\u51c6<br>\u2022 \u672c\u6848\u4f8b\u5f3a\u8c03\u914d\u7f6e\u900f\u660e\uff0c\u53ef\u9010\u9879\u6838\u5bf9\u9762\u79ef\u3001\u51b7\u6307\u6807\u3001\u578b\u53f7\uff0c\u7edd\u4e0d\u865a\u9ad8<br><br>\ud83d\udee1\ufe0f <strong>\u5173\u4e8e\u8d28\u4fdd<\/strong><br>\u2022 \u6807\u51c6\u8d28\u4fdd5\u5e74<br>\u2022 \u53ef+420\u5143\u5ef6\u4fdd\u81f310\u5e74<\/div>\n\n        <h3 class=\"card-title\" style=\"margin-top:22px\">\u80fd\u8017\u5bf9\u6bd4\u4e0e\u56de\u672c\u6d4b\u7b97 \u00b7 \u9ad8\u80fd\u6548\u7684\u957f\u671f\u4ef7\u503c<\/h3>\n        <p>\u4ee5\u6210\u90fd\u5730\u533a\u4f7f\u7528\u4e60\u60ef\u4f30\u7b97\uff1a\u5236\u51b7\u5b63\u7ea64.5\u4e2a\u6708\uff08\u65e5\u574710h\uff09+ \u5236\u70ed\u5b63\u7ea61\u4e2a\u6708\uff08\u65e5\u57478h\uff09\uff0c\u5e74\u8fd0\u884c\u7ea6 <b class=\"bold-spec\">1590\u5c0f\u65f6<\/b>\u3002\u5bf9\u6bd4\u65e5\u7acb\u8212\u4eab160\uff08APF 5.80\uff0c\u65b0\u56fd\u6807\u4e00\u7ea7\uff09\u4e0e\u8001\u5f0f\u4e09\u7ea7\u80fd\u6548\u673a\u578b\uff08APF \u7ea64.0\uff09\uff1a<\/p>\n        <table class=\"info-table\">\n          <tbody><tr><th>\u6d4b\u7b97\u9879<\/th><th>\u8212\u4eab160\uff08APF 5.80\uff09<\/th><th>\u8001\u4e09\u7ea7\u80fd\u6548\uff08APF 4.0\uff09<\/th><th>\u5dee\u989d \/ \u8bf4\u660e<\/th><\/tr>\n            <tr><td>\u76f8\u5bf9\u80fd\u6548\u6bd4<\/td><td><b class=\"bold-spec\">1.45\u00d7<\/b>\uff085.80\u00f74.0\uff09<\/td><td>\u57fa\u51c6 1.0\u00d7<\/td><td>\u540c\u7b49\u51b7\u91cf\u4e0b\u7701\u7535\u7ea6 31%<\/td><\/tr>\n            <tr><td>\u5e74\u8017\u7535\u91cf\uff08\u4f30\uff09<\/td><td>\u7ea6 2,690 kWh<\/td><td>\u7ea6 3,900 kWh<\/td><td>\u5e74\u7701\u7ea6 1,210 kWh<\/td><\/tr>\n            <tr><td>\u5e74\u7535\u8d39\uff080.55\u5143\/kWh\uff09<\/td><td>\u7ea6 1,479 \u5143<\/td><td>\u7ea6 2,145 \u5143<\/td><td>\u5e74\u7701\u7ea6 <b class=\"bold-spec\">666 \u5143<\/b><\/td><\/tr>\n            <tr><td>5\u5e74\u7d2f\u8ba1\u7701<\/td><td colspan=\"2\">\u2014<\/td><td>\u7ea6 3,330 \u5143<\/td><\/tr>\n            <tr><td>10\u5e74\u7d2f\u8ba1\u7701<\/td><td colspan=\"2\">\u2014<\/td><td>\u7ea6 6,660 \u5143<\/td><\/tr>\n            <tr><td>20\u5e74\u7d2f\u8ba1\u7701<\/td><td colspan=\"2\">\u2014<\/td><td>\u7ea6 13,320 \u5143<\/td><\/tr>\n            <tr><td>\u56de\u672c\u5468\u671f<\/td><td colspan=\"2\">\u2014<\/td><td>\u9ad8\u80fd\u6548\u673a\u578b\u521d\u671f\u5dee\u4ef7\u7ea6 2,000~4,000 \u5143\uff0c<b class=\"bold-spec\">\u7ea6 5~6 \u5e74\u56de\u672c<\/b>\uff0c\u4e4b\u540e\u5747\u4e3a\u51c0\u7701<\/td><\/tr>\n          <\/tbody><\/table>\n        <p style=\"font-size:0.82rem;color:var(--text-gray);margin-top:8px\">\u26a0\ufe0f \u6d4b\u7b97\u57fa\u4e8e\u6210\u90fd\u540c\u6237\u578b\u53c2\u8003\u503c\uff08\u5e74\u8fd0\u884c1590h\u3001\u7535\u4ef70.55\u5143\/kWh\u3001\u8001\u673aAPF4.0\uff09\uff0c\u5b9e\u9645\u56e0\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u6e29\u3001\u7535\u4ef7\u6d6e\u52a8\u800c\u5f02\uff1b\u6570\u636e\u7528\u4e8e\u8bf4\u660e\u9ad8\u80fd\u6548\u957f\u671f\u4ef7\u503c\uff0c\u975e\u627f\u8bfa\u503c\u3002<\/p>\n      <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"step-section\" id=\"s4\">\n    <input type=\"checkbox\" id=\"fold-s4\" class=\"fold-cb\">\n    <label for=\"fold-s4\" class=\"fold-lbl\"><h2 class=\"step-head\">S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c<span class=\"fold-ico\">\u25be \u5c55\u5f00\/\u6536\u8d77<\/span><\/h2><\/label>\n    <div class=\"fold-body\">\n      <div class=\"section-tabs\">\n        <span class=\"section-tab active\" data-section=\"s4\" data-card=\"0\">\u516d\u6b65\u7cbe\u5de5<\/span>\n        <span class=\"section-tab\" data-section=\"s4\" data-card=\"1\">\u65bd\u5de5\u5b9e\u62cd\u56fe\u96c6<\/span>\n        <span class=\"section-tab\" data-section=\"s4\" data-card=\"2\">\u9f99\u8109\u7cbe\u5de5vs\u884c\u4e1a<\/span>\n        <span class=\"section-tab\" data-section=\"s4\" data-card=\"3\">\u91cf\u5316\u9a8c\u6536\u7ec6\u8282<\/span>\n        <span class=\"section-tab\" data-section=\"s4\" data-card=\"4\">\u4ea4\u4ed8\u6559\u5b66+\u552e\u540e\u4fdd\u969c<\/span>\n        <span class=\"section-tab\" data-section=\"s4\" data-card=\"5\">\u54c1\u724c\u6388\u6743\u8ba4\u8bc1<\/span>\n      <\/div>\n\n      <div class=\"slider-container\">\n      <div class=\"content-card slider-card active\">\n        <h3 class=\"card-title\">\u516d\u6b65\u7cbe\u5de5\u6d41\u7a0b\uff08\u8212\u4eab160 \u4e00\u62d6\u4e94\u5b89\u88c5\uff09<\/h3>\n        <div class=\"timeline\" id=\"timeline\">\n          <div class=\"timeline-step active\" data-step=\"0\"><div class=\"timeline-dot\">1<\/div><div class=\"timeline-label\">\u73b0\u573a\u52d8\u6d4b<br>\u5b9a\u4f4d\u653e\u6837<\/div><\/div>\n          <div class=\"timeline-step\" data-step=\"1\"><div class=\"timeline-dot\">2<\/div><div class=\"timeline-label\">\u5185\u673a\u540a\u88c5<br>\u7ba1\u8def\u94fa\u8bbe<\/div><\/div>\n          <div class=\"timeline-step\" data-step=\"2\"><div class=\"timeline-dot\">3<\/div><div class=\"timeline-label\">\u51b7\u5a92\u710a\u63a5<br>\u6c2e\u6c14\u4fdd\u62a4<\/div><\/div>\n          <div class=\"timeline-step\" data-step=\"3\"><div class=\"timeline-dot\">4<\/div><div class=\"timeline-label\">\u5916\u673a\u5b89\u88c5<br>\u4fdd\u538b\u6d4b\u8bd5<\/div><\/div>\n          <div class=\"timeline-step\" data-step=\"4\"><div class=\"timeline-dot\">5<\/div><div class=\"timeline-label\">\u7cfb\u7edf\u8054\u8c03<br>\u7ebf\u63a7\u5668\u8c03\u8bd5<\/div><\/div>\n          <div class=\"timeline-step\" data-step=\"5\"><div class=\"timeline-dot\">6<\/div><div class=\"timeline-label\">\u4ea4\u4ed8\u6559\u5b66<br>\u552e\u540e\u5efa\u6863<\/div><\/div>\n        <\/div>\n        <div class=\"timeline-detail show\" id=\"timelineDetail0\"><div class=\"step-num\">\u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b\u00b7\u5b9a\u4f4d\u653e\u6837<\/div><p>\u6309\u8bbe\u8ba1\u56fe\u7eb8\u786e\u8ba4\u5e73\u5c42103.87\u33a1\u5404\u623f\u95f4\u7a7a\u8c03\u533a\u57df\uff0c\u6838\u5bf9\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u3001\u5bb6\u5ead\u5ba430.9\u33a1\u3001\u4e3b\u536715.3\u33a1\u3001\u6b21\u536714.27\u33a1\u7684\u5b9e\u9645\u5c3a\u5bf8\u4e0e\u56fe\u7eb8\u4e00\u81f4\u6027\u3002\u786e\u5b9a5\u53f0\u5185\u673a\u540a\u88c5\u70b9\u4f4d\uff08\u907f\u5f00\u6881\u4f4d\u4e0e\u706f\u5177\u4f4d\u7f6e\uff09\u3001\u51b7\u51dd\u6c34\u7ba1\u8d70\u5411\u4e0e\u5761\u5ea6\u3001\u5916\u673a\u4f4d\u9884\u7559\uff08\u5355\u98ce\u6247\u5916\u673a\u9700\u8db3\u591f\u6563\u70ed\u7a7a\u95f4\uff09\u3001\u7ebf\u63a7\u5668\u5899\u9762\u5f00\u5b54\u4f4d\u7f6e\u3002\u6807\u8bb0\u6240\u6709\u7ba1\u8def\u8d70\u5411\u5e76\u62cd\u7167\u5b58\u6863\u3002<\/p><\/div>\n        <div class=\"timeline-detail\" id=\"timelineDetail1\"><div class=\"step-num\">\u7b2c\u4e8c\u6b65\uff1a\u5185\u673a\u540a\u88c5\u00b7\u7ba1\u8def\u94fa\u8bbe<\/div><p>5\u53f0\u65e5\u7acb\u8212\u4eab\u5185\u673a\u4f9d\u6b21\u540a\u88c5\u5c31\u4f4d\uff1a\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623fRPIZ-50FSNAQD\/P\u4e0eRPIZ-22FSNAQD\/P\uff08\u4e24\u53f0\u5185\u673a\u6ce8\u610f\u52a0\u56fa\u4e0e\u95f4\u8ddd\uff09\u3001\u5bb6\u5ead\u5ba4RPIZ-63FSNAQD\/P\u3001\u4e3b\u5367RPIZ-25FSNAQD\/P\u3001\u6b21\u5367RPIZ-25FSNAQD\/P\u3002\u6bcf\u53f0\u5185\u673a\u6c34\u5e73\u6821\u51c6\u3001\u51b7\u51dd\u6c34\u76d8\u5761\u5ea6\u786e\u8ba4\u3002\u51b7\u5a92\u7ba1\u8def\u548c\u51b7\u51dd\u6c34\u7ba1\u540c\u6b65\u94fa\u8bbe\uff0c\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6301\u22651%\u5761\u5ea6\u786e\u4fdd\u6392\u6c34\u987a\u7545\u4e0d\u5012\u5761\u3002<\/p><\/div>\n        <div class=\"timeline-detail\" id=\"timelineDetail2\"><div class=\"step-num\">\u7b2c\u4e09\u6b65\uff1a\u51b7\u5a92\u710a\u63a5\u00b7\u6c2e\u6c14\u4fdd\u62a4<\/div><p>\u51b7\u5a92\u94dc\u7ba1\u8fde\u63a5\u5904\u91c7\u7528<b class=\"bold-spec\">\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5<\/b>\uff0c\u710a\u63a5\u8fc7\u7a0b\u6301\u7eed\u5145\u5165\u6c2e\u6c14\u9632\u6b62\u94dc\u7ba1\u5185\u58c1\u6c27\u5316\u4ea7\u751f\u710a\u6e23\u2014\u2014\u8fd9\u662f\u4fdd\u969c\u7cfb\u7edf\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\u7684\u5173\u952e\u5de5\u5e8f\uff0c\u6c27\u5316\u710a\u6e23\u8fdb\u5165\u538b\u7f29\u673a\u4f1a\u5bfc\u81f4\u635f\u574f\u3002\u6bcf\u4e00\u9053\u710a\u53e3\u5b8c\u6210\u540e\u68c0\u67e5\u5916\u89c2\u5e76\u62cd\u7167\u7559\u6863\u3002<\/p><\/div>\n        <div class=\"timeline-detail\" id=\"timelineDetail3\"><div class=\"step-num\">\u7b2c\u56db\u6b65\uff1a\u5916\u673a\u5b89\u88c5\u00b7\u4fdd\u538b\u6d4b\u8bd5<\/div><p>\u65e5\u7acbRAS-160HRNAQ\u8212\u4eab160\u5355\u98ce\u6247\u5916\u673a\u5c31\u4f4d\u5b89\u88c5\uff0c\u786e\u8ba4\u57fa\u7840\u7262\u56fa\u3001\u6c34\u5e73\u6821\u6b63\u3001\u56db\u5468\u7559\u8db3\u6563\u70ed\u7a7a\u95f4\uff08\u2265300mm\uff09\u3002\u51b7\u5a92\u7ba1\u8def\u8fde\u63a5\u5b8c\u6210\u540e\u8fdb\u884c\u62bd\u771f\u7a7a\u4e0e<b class=\"bold-spec\">\u6c2e\u6c14\u4fdd\u538b\u6d4b\u8bd5\u226524\u5c0f\u65f6<\/b>\uff0c\u538b\u964d\uff1c0.02MPa\u5224\u5b9a\u5408\u683c\u3002\u4fdd\u538b\u671f\u95f4\u5168\u7a0b\u62cd\u7167\u8bb0\u5f55\u538b\u529b\u8868\u8bfb\u6570\u3002<\/p><\/div>\n        <div class=\"timeline-detail\" id=\"timelineDetail4\"><div class=\"step-num\">\u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8054\u8c03\u00b7\u7ebf\u63a7\u5668\u8c03\u8bd5<\/div><p>\u5168\u7cfb\u7edf\u5145\u6ce8\u51b7\u5a92\u540e\u9010\u4e00\u542f\u52a85\u53f0\u5185\u673a\uff0c\u68c0\u6d4b\u5236\u51b7\u6548\u679c\u3001\u51fa\u98ce\u6e29\u5ea6\u3001\u8fd0\u884c\u7535\u6d41\u662f\u5426\u6b63\u5e38\u30025\u4e2a\u7ebf\u63a7\u5668\u5206\u522b\u8c03\u8bd5\uff1a\u6e29\u5ea6\u8bbe\u5b9a\u8303\u56f4\u3001\u6a21\u5f0f\u5207\u6362\uff08\u5236\u51b7\/\u5236\u70ed\/\u9001\u98ce\/\u9664\u6e7f\uff09\u3001\u98ce\u901f\u8c03\u8282\u3001\u5b9a\u65f6\u5f00\u5173\u529f\u80fd\u3002\u6a21\u62df\u65e5\u5e38\u4f7f\u7528\u573a\u666f\uff1a\u5355\u5f00\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u3001\u4e3b\u5367+\u6b21\u5367\u540c\u5f00\u3001\u5168\u5c4b5\u53f0\u540c\u5f00\u4e09\u79cd\u6a21\u5f0f\u5747\u6d4b\u8bd5\u901a\u8fc7\u3002<\/p><\/div>\n        <div class=\"timeline-detail\" id=\"timelineDetail5\"><div class=\"step-num\">\u7b2c\u516d\u6b65\uff1a\u4ea4\u4ed8\u6559\u5b66\u00b7\u552e\u540e\u5efa\u6863<\/div><p>\u4e00\u5bf9\u4e00\u6559\u4f1a\u8521\u8001\u5e08\u4f7f\u7528\u7ebf\u63a7\u5668\u57fa\u672c\u64cd\u4f5c\uff08\u5f00\u5173\u3001\u8c03\u6e29\u3001\u5207\u6362\u6a21\u5f0f\uff09\uff0c\u8bb2\u89e3\u65e5\u5e38\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff08\u6ee4\u7f51\u6e05\u6d01\u5468\u671f\u3001\u5b63\u8282\u5207\u6362\u3001\u957f\u65f6\u95f4\u4e0d\u7528\u65f6\u7684\u4fdd\u517b\u8981\u70b9\uff09\u3002\u4ea4\u4ed8\u300a\u4f7f\u7528\u7ef4\u62a4\u624b\u518c\u300b\u7535\u5b50\u7248\u4e0e\u7eb8\u8d28\u7248\u3002\u5efa\u7acb\u552e\u540e\u6863\u6848\uff0c\u7eb3\u5165\u9f99\u8109\u6696\u901a\u8d28\u4fdd\/\u5ef6\u4fdd\u4f53\u7cfb\u3002<\/p><\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u65bd\u5de5\u5b9e\u62cd\u56fe\u96c6\uff08\u6309\u5de5\u5e8f\u5206\u7ec4\uff09<\/h3>\n        <div class=\"gallery-group\">\n          <div class=\"gallery-group-title\">\ud83d\udd27 \u5185\u673a\u5b89\u88c5\u5b9e\u666f<\/div>\n          <div class=\"photo-grid-h cols-4\">\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-01.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-01\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-01<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-02.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-02\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-02<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-03.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-03\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-03<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-04.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-04\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-04<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-05.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-05\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5185\u673a\u5b89\u88c5\u5b9e\u666f-05<\/figcaption><\/figure>\n          <\/div>\n        <\/div>\n        <div class=\"gallery-group\">\n          <div class=\"gallery-group-title\">\ud83d\udee0\ufe0f \u7ba1\u8def\u8d70\u7ba1<\/div>\n          <div class=\"photo-grid-h cols-4\">\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-glzg-01.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7ba1\u8def\u8d70\u7ba1-01\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7ba1\u8def\u8d70\u7ba1-01<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-glzg-02.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7ba1\u8def\u8d70\u7ba1-02\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7ba1\u8def\u8d70\u7ba1-02<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-glzg-03.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7ba1\u8def\u8d70\u7ba1-03\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7ba1\u8def\u8d70\u7ba1-03<\/figcaption><\/figure>\n          <\/div>\n        <\/div>\n        <div class=\"gallery-group\">\n          <div class=\"gallery-group-title\">\u2744\ufe0f \u5916\u673a\u5b89\u88c5\u5b9e\u666f<\/div>\n          <div class=\"photo-grid-h cols-2\">\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-wjazsj.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5916\u673a\u5b89\u88c5\u5b9e\u666f\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u5916\u673a\u5b89\u88c5\u5b9e\u666f<\/figcaption><\/figure>\n          <\/div>\n        <\/div>\n        <div class=\"gallery-group\">\n          <div class=\"gallery-group-title\">\u2705 \u9690\u853d\u5de5\u7a0b\u9a8c\u6536 \u00b7 \u4fdd\u538b \/ \u7ebf\u63a7\u5668<\/div>\n          <div class=\"photo-grid-h cols-2\">\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-ktylb.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7a7a\u8c03\u538b\u529b\u8868\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7a7a\u8c03\u538b\u529b\u8868<\/figcaption><\/figure>\n            <figure class=\"ph\"><div class=\"ph-img-wrap rotate-fix\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-ktxkqmb.jpg\" alt=\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7a7a\u8c03\u7ebf\u63a7\u5668\u9762\u677f\" loading=\"lazy\"><\/div><figcaption class=\"ph-cap\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8-\u8521\u8001\u5e08-\u7a7a\u8c03\u7ebf\u63a7\u5668\u9762\u677f<\/figcaption><\/figure>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u9f99\u8109\u7cbe\u5de5 vs \u884c\u4e1a\u5e38\u89c4<\/h3>\n        <table class=\"compare-table\">\n          <tbody><tr><th>\u5bf9\u6bd4\u9879<\/th><th class=\"highlight\">\u9f99\u8109\u7cbe\u5de5<\/th><th>\u884c\u4e1a\u5e38\u89c4\uff08\u4f4e\u4ef7\uff09<\/th><\/tr>\n          <tr><td>\u51b7\u5a92\u710a\u63a5<\/td><td class=\"highlight\">\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5\uff0c\u675c\u7edd\u6c27\u5316<\/td><td>\u76f4\u63a5\u710a\uff0c\u6613\u4ea7\u751f\u710a\u6e23<\/td><\/tr>\n          <tr><td>\u4fdd\u538b\u6d4b\u8bd5<\/td><td class=\"highlight\">\u62bd\u771f\u7a7a+\u6c2e\u6c14\u4fdd\u538b\u226524h<\/td><td>\u8349\u8349\u4e86\u4e8b\u6216\u8df3\u8fc7<\/td><\/tr>\n          <tr><td>\u5185\u673a\u540a\u88c5<\/td><td class=\"highlight\">\u6c34\u5e73\u6821\u51c6+\u52a0\u56fa+\u51b7\u51dd\u6c34\u5761\u5ea6\u786e\u8ba4<\/td><td>\u6302\u4e0a\u53bb\u5c31\u884c<\/td><\/tr>\n          <tr><td>\u7ba1\u8def\u5de5\u827a<\/td><td class=\"highlight\">\u51b7\u5a92\u7ba1\u4fdd\u6e29+\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22651%<\/td><td>\u4fdd\u6e29\u4e0d\u5230\u4f4d\u3001\u5012\u5761\u9690\u60a3<\/td><\/tr>\n          <tr><td>\u8c03\u8bd5\u6807\u51c6<\/td><td class=\"highlight\">\u9010\u673a\u68c0\u6d4b+\u4e09\u79cd\u6a21\u5f0f\u6a21\u62df<\/td><td>\u5f00\u673a\u770b\u770b\u51c9\u4e0d\u51c9\u5c31\u884c<\/td><\/tr>\n          <tr><td>\u9a8c\u6536\u6807\u51c6<\/td><td class=\"highlight\">36\u9879\u8282\u70b9\u9a8c\u6536+\u5f71\u50cf\u7559\u6863<\/td><td>\u53e3\u5934\u9a8c\u6536<\/td><\/tr>\n        <\/tbody><\/table>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">4\u9879\u91cf\u5316\u9690\u853d\u9a8c\u6536\u7ec6\u8282<\/h3>\n        <div class=\"info-row\">\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/div><div class=\"lbl\">\u4e3b\u673a\/5\u53f0\u5185\u673a\/\u94dc\u7ba1\/\u4fdd\u6e29\u6750\u6599\u9010\u4e00\u6838\u9a8c\u54c1\u724c\u578b\u53f7\u4e0e\u5408\u683c\u8bc1<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u51b7\u5a92\u7ba124h\u771f\u7a7a\u4fdd\u538b<\/div><div class=\"lbl\">\u62bd\u771f\u7a7a\u540e\u5145\u6c2e\u4fdd\u538b\u226524h\uff0c\u538b\u964d\uff1c0.02MPa\u5224\u5b9a\u5408\u683c<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u51b7\u51dd\u6c34\u7ba1\u704c\u6c34\u8bd5\u9a8c<\/div><div class=\"lbl\">\u6bcf\u53f0\u5185\u673a\u51b7\u51dd\u6c34\u76d8\u704c\u6c34\u786e\u8ba4\u6392\u6c34\u901a\u7545\u65e0\u6e17\u6f0f<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u9010\u673a\u8fd0\u884c\u7535\u6d41\u68c0\u6d4b<\/div><div class=\"lbl\">5\u53f0\u5185\u673a\u5206\u522b\u542f\u52a8\uff0c\u68c0\u6d4b\u8fd0\u884c\u7535\u6d41\u5728\u989d\u5b9a\u8303\u56f4\u5185<\/div><\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u4ea4\u4ed8\u6559\u5b66 + \u552e\u540e\u4fdd\u969c<\/h3>\n        <div class=\"note-skeleton\">\ud83c\udf93 <strong>\u4ea4\u4ed8\u6559\u5b66<\/strong><br>\u4e00\u5bf9\u4e00\u6559\u4f1a\u8521\u8001\u5e08\u4f7f\u7528\u7ebf\u63a7\u5668\u57fa\u672c\u64cd\u4f5c\uff08\u5f00\u5173\u673a\u3001\u6e29\u5ea6\u8bbe\u5b9a\u3001\u6a21\u5f0f\u5207\u6362\u3001\u98ce\u901f\u8c03\u8282\uff09\uff0c\u8bb2\u89e3\u65e5\u5e38\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\uff1a\u6ee4\u7f51\u6bcf2~3\u4e2a\u6708\u6e05\u6d01\u4e00\u6b21\u3001\u6362\u5b63\u524d\u68c0\u67e5\u51b7\u51dd\u6c34\u6392\u6c34\u3001\u957f\u65f6\u95f4\u4e0d\u7528\u65f6\u5efa\u8bae\u6bcf\u6708\u77ed\u65f6\u95f4\u5f00\u673a\u8fd0\u884c\u9632\u6f6e\u3002\u63d0\u4f9b\u7535\u5b50\u7248\u4e0e\u7eb8\u8d28\u7248\u300a\u4f7f\u7528\u7ef4\u62a4\u624b\u518c\u300b\u3002\u5168\u7a0b\u7531\u9f99\u8109\u6696\u901a<b class=\"bold-spec\">\u76f4\u8425\u73ed\u7ec4<\/b>\u65bd\u5de5\uff0c\u65e0\u5916\u5305\u3002<\/div>\n        <div class=\"note-skeleton\">\ud83d\udee1\ufe0f <strong>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/strong><br>\u80fd\u8017\u6570\u636e\u9010\u5e74\u5f52\u6863 \u2192 \u540c\u6237\u578b\u5bf9\u6807\u5206\u6790 \u2192 \u5f02\u5e38\u4e3b\u52a8\u9884\u8b66 \u2192 \u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u4f18\u5316\u300210\u5e74\u5185\u56e0\u8bbe\u8ba1\u6216\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u80fd\u8017\u5f02\u5e38\uff0c\u9f99\u8109\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u5e76\u8c03\u6574\u3002<\/div>\n        <div class=\"promise-grid\">\n          <div class=\"promise-card\"><div class=\"promise-num\">01<\/div><div class=\"promise-title\">\u6574\u673a\u4fdd\u4fee<\/div><div class=\"promise-desc\">\u65e5\u7acb\u8212\u4eab160\u5916\u673a\u53ca5\u53f0\u5185\u673a\u539f\u5382\u4fdd\u4fee<\/div><\/div>\n          <div class=\"promise-card\"><div class=\"promise-num\">02<\/div><div class=\"promise-title\">\u5b89\u88c5\u8d28\u4fdd<\/div><div class=\"promise-desc\">\u9f99\u8109\u6696\u901a\u627f\u8bfa\u5b89\u88c5\u90e8\u5206\u8d28\u4fdd<\/div><\/div>\n          <div class=\"promise-card\"><div class=\"promise-num\">03<\/div><div class=\"promise-title\">\u4e0d\u6ee1\u610f\u91cd\u88c5<\/div><div class=\"promise-desc\">\u5b89\u88c5\u9a8c\u6536\u4e0d\u8fbe\u6807\uff0c\u514d\u8d39\u91cd\u88c5<\/div><\/div>\n          <div class=\"promise-card\"><div class=\"promise-num\">04<\/div><div class=\"promise-title\">\u96f6\u589e\u9879\u627f\u8bfa<\/div><div class=\"promise-desc\">\u5408\u540c\u4ef7\u683c\u5373\u4e3a\u6700\u7ec8\u4ef7\u683c\uff0c\u65bd\u5de5\u4e0d\u589e\u9879<\/div><\/div>\n          <div class=\"promise-card\"><div class=\"promise-num\">05<\/div><div class=\"promise-title\">\u8fdb\u5ea6\u8d85\u671f\u8d54\u507f<\/div><div class=\"promise-desc\">\u8d85\u5de5\u671f\u6bcf\u65e5\u6309\u5408\u540c\u989d0.1%\u8d54\u507f<\/div><\/div>\n          <div class=\"promise-card\"><div class=\"promise-num\">06<\/div><div class=\"promise-title\">7\u5929\u65e0\u7406\u7531<\/div><div class=\"promise-desc\">\u5b89\u88c5\u524d7\u5929\u5185\u53ef\u65e0\u7406\u7531\u53d6\u6d88\u5168\u989d\u9000\u6b3e<\/div><\/div>\n        <\/div>\n        <p style=\"margin-top:12px;font-size:0.85rem\">\n          <strong>\ud83c\udfea \u5357\u5bcc\u68ee\u5e97\uff1a<\/strong>\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348 \u00b7 028-86131795<br>\n          <strong>\ud83c\udfea \u5317\u5bcc\u68ee\u5e97\uff1a<\/strong>\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135 \u00b7 028-65272586<br>\n\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u54c1\u724c\u6388\u6743\u8ba4\u8bc1\uff08S4\u65bd\u5de5\u677f\u5757\u672b\u5c3e \u00b7 \u8d44\u8d28\u56fe\u96c6\uff09<\/h3>\n        <div class=\"cert-grid\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u6388\u6743\u8d44\u8d28\u5b9e\u62cd\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u5546\u6388\u6743\u8d44\u8d28\u5b9e\u62cd\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u5546\u6388\u6743\u8d44\u8d28\u5b9e\u62cd\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8d44\u8d28\u5b9e\u62cd\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6c34\u5885\u58eb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8d44\u8d28\u5b9e\u62cd\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <\/div>\n        <p style=\"color:var(--text-gray);font-size:0.85rem\">\u9f99\u8109\u6696\u901a2026\u65e5\u7acb\u5b98\u65b9<b class=\"bold-spec\">\u94bb\u77f3\u5b89\u88c5\u5546<\/b>\u3001\u7279\u7ea6\u7ecf\u9500\/\u5b89\u88c5\u6388\u6743\uff0c\u5382\u5bb6\u76f4\u4fdd\u65bd\u5de5 \u00b7 22\u5e74\u4e13\u4e1a\u7ecf\u9a8c \u00b7 \u4e13\u5c5e\u670d\u52a1\u901a\u9053<\/p>\n      <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"step-section\" id=\"s5\">\n    <input type=\"checkbox\" id=\"fold-s5\" class=\"fold-cb\">\n    <label for=\"fold-s5\" class=\"fold-lbl\"><h2 class=\"step-head\">S5 \u00b7 \u6848\u4f8b\u590d\u76d8 &amp; \u4e13\u4e1a\u4e3b\u5f20 &amp; FAQ\u95ee\u7b54<span class=\"fold-ico\">\u25be \u5c55\u5f00\/\u6536\u8d77<\/span><\/h2><\/label>\n    <div class=\"fold-body\">\n      <div class=\"section-tabs\">\n        <span class=\"section-tab active\" data-section=\"s5\" data-card=\"0\">\u6848\u4f8b\u590d\u76d8<\/span>\n        <span class=\"section-tab\" data-section=\"s5\" data-card=\"1\">\u4e13\u4e1a\u4e3b\u5f20<\/span>\n        <span class=\"section-tab\" data-section=\"s5\" data-card=\"2\">\u98ce\u9669\u544a\u77e5<\/span>\n        <span class=\"section-tab\" data-section=\"s5\" data-card=\"3\">\u6696\u901a\u8d34\u58eb<\/span>\n        <span class=\"section-tab\" data-section=\"s5\" data-card=\"4\">\u4e1a\u4e3b\u95ee\u7b54<\/span>\n      <\/div>\n\n      <div class=\"slider-container\">\n      <div class=\"content-card slider-card active\">\n        <h3 class=\"card-title\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u5e73\u5c42\u6848\u4f8b\u590d\u76d8 \u00b7 \u4e3a\u4ec0\u4e48\u9009\u8212\u4eab160<\/h3>\n        <p style=\"margin:6px 0 14px;font-size:0.86rem;color:#555\">\u4ece<b class=\"bold-spec\">\u6237\u578b\u9002\u914d \u00b7 \u9884\u7b97\u5e73\u8861 \u00b7 \u957f\u671f\u80fd\u8017 \u00b7 \u65bd\u5de5\u9002\u914d<\/b> \u56db\u5927\u7ef4\u5ea6\uff0c\u590d\u76d8\u672c\u5e73\u5c42103.87\u33a1\u4e3a\u4f55\u6700\u7ec8\u9501\u5b9a\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u3002<\/p>\n\n        <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;margin:0 0 18px 0\">\n          <tbody><tr>\n            <td style=\"padding:6px 5px;vertical-align:top;width:25%\">\n              <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;border:1px solid #e8e8e8;border-radius:12px;overflow:hidden;background:#fff\">\n                <tbody>\n                  <tr><td style=\"padding:16px 14px 10px;text-align:center\">\n                    <table cellpadding=\"0\" cellspacing=\"0\" style=\"margin:0 auto;border-collapse:collapse\"><tbody><tr><td style=\"width:44px;height:44px;background:#f0f4ff;border-radius:50%;text-align:center;font-size:22px;line-height:44px\">\ud83d\udcd0<\/td><\/tr><\/tbody><\/table>\n                    <div style=\"margin-top:8px;font-size:0.72rem;color:#e53935;background:#fef0f0;display:inline-block;padding:2px 12px;border-radius:12px;font-weight:600;letter-spacing:0.5px\">\u6838\u5fc3\u51b3\u7b56<\/div>\n                  <\/td><\/tr>\n                  <tr><td style=\"padding:0 14px 12px\">\n                    <div style=\"font-size:0.95rem;font-weight:800;color:#1a2332;margin-bottom:8px;line-height:1.4\">\u7cbe\u51c6\u9009\u578b<br>\u9884\u7559\u5168\u5c4b\u540c\u5f00\u4f59\u91cf<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u73b0\u72b6\uff1a<\/b>\u5e73\u5c42103.87\u33a1\u6309GB\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c5\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u4f9d\u636e\uff1a<\/b>18500W\u5339\u914d15500W\u5916\u673a\uff0c\u8fde\u63a5\u7387119.4%\u5728\u65e5\u7acb\u5b89\u5168\u7ecf\u6d4e\u533a\u95f4\u5185\uff0c\u5168\u5c4b5\u53f0\u540c\u5f00\u4e5f\u591f\u7528\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#e53935;line-height:1.7;padding-top:6px;border-top:1px dashed #eee\"><b style=\"color:#e53935\">\u65b9\u6848\uff1a<\/b>RAS-160HRNAQ\u5916\u673a+\u4e00\u62d6\u4e94\u914d\u7f6e\uff0c\u5236\u51b7\u5feb\u3001\u9759\u97f3\u3001\u7701\u7535\uff0c\u6bd4125\/140\u578b\u66f4\u4ece\u5bb9\u5e94\u5bf9\u5168\u5c4b\u540c\u5f00\u3002<\/div>\n                  <\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/td>\n            <td style=\"padding:6px 5px;vertical-align:top;width:25%\">\n              <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;border:1px solid #e8e8e8;border-radius:12px;overflow:hidden;background:#fff\">\n                <tbody>\n                  <tr><td style=\"padding:16px 14px 10px;text-align:center\">\n                    <table cellpadding=\"0\" cellspacing=\"0\" style=\"margin:0 auto;border-collapse:collapse\"><tbody><tr><td style=\"width:44px;height:44px;background:#fff8e6;border-radius:50%;text-align:center;font-size:22px;line-height:44px\">\ud83c\udfe0<\/td><\/tr><\/tbody><\/table>\n                    <div style=\"margin-top:8px;font-size:0.72rem;color:#e65100;background:#fff3e0;display:inline-block;padding:2px 12px;border-radius:12px;font-weight:600;letter-spacing:0.5px\">\u75db\u70b9<\/div>\n                  <\/td><\/tr>\n                  <tr><td style=\"padding:0 14px 12px\">\n                    <div style=\"font-size:0.95rem;font-weight:800;color:#1a2332;margin-bottom:8px;line-height:1.4\">\u5927\u516c\u533a74.3\u33a1<br>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f+\u5bb6\u5ead\u5ba4<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u73b0\u72b6\uff1a<\/b>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u4e0e\u5bb6\u5ead\u5ba430.9\u33a1\u5408\u8ba174.3\u33a1\uff0c\u662f\u672c\u6848\u6700\u5927\u7a7a\u8c03\u533a\u57df\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u4f9d\u636e\uff1a<\/b>\u5927\u7a7a\u95f4\u5355\u53f0\u5185\u673a\u96be\u4ee5\u5feb\u901f\u5747\u5300\u964d\u6e29\uff0c\u591a\u53f0\u5185\u673a\u5206\u533a\u9001\u51b7\u66f4\u5408\u7406\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#e53935;line-height:1.7;padding-top:6px;border-top:1px dashed #eee\"><b style=\"color:#e65100\">\u65b9\u6848\uff1a<\/b>\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u9009<span style=\"color:#e65100;font-weight:700\">RPIZ-50\uff085000W\uff09+RPIZ-22\uff082200W\uff09<\/span>\u53cc\u5185\u673a\uff0c\u5bb6\u5ead\u5ba4\u5355\u53f0<span style=\"color:#e65100;font-weight:700\">RPIZ-63\uff086300W\uff09<\/span>\uff0c\u786e\u4fdd\u5feb\u901f\u964d\u6e29\u65e0\u6b7b\u89d2\u3002<\/div>\n                  <\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/td>\n            <td style=\"padding:6px 5px;vertical-align:top;width:25%\">\n              <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;border:1px solid #e8e8e8;border-radius:12px;overflow:hidden;background:#fff\">\n                <tbody>\n                  <tr><td style=\"padding:16px 14px 10px;text-align:center\">\n                    <table cellpadding=\"0\" cellspacing=\"0\" style=\"margin:0 auto;border-collapse:collapse\"><tbody><tr><td style=\"width:44px;height:44px;background:#fce4ec;border-radius:50%;text-align:center;font-size:22px;line-height:44px\">\u26a1<\/td><\/tr><\/tbody><\/table>\n                    <div style=\"margin-top:8px;font-size:0.72rem;color:#c62828;background:#fce4ec;display:inline-block;padding:2px 12px;border-radius:12px;font-weight:600;letter-spacing:0.5px\">\u6838\u5fc3\u4f18\u52bf<\/div>\n                  <\/td><\/tr>\n                  <tr><td style=\"padding:0 14px 12px\">\n                    <div style=\"font-size:0.95rem;font-weight:800;color:#1a2332;margin-bottom:8px;line-height:1.4\">\u573a\u666f\u5b8c\u7f8e\u5339\u914d<br>\u90e8\u5206\u8d1f\u8377\u9ad8\u6548\u533a<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u73b0\u72b6\uff1a<\/b>\u767d\u5929\u5f00\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u3001\u665a\u4e0a\u4e3b\u5367+\u6b21\u5367\u3001\u5076\u5c14\u5168\u5c4b5\u53f0\u540c\u5f00\u2014\u2014\u4e09\u79cd\u573a\u666f\u8d1f\u8f7d\u5404\u4e0d\u540c\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u4f9d\u636e\uff1a<\/b>\u767d\u5929\u516c\u533a46.5% \/ \u665a\u4e0a\u5367\u5ba432.3%\uff0c\u5916\u673a\u5728\u9ad8\u8d1f\u8f7d\u4e0e\u90e8\u5206\u8d1f\u8377\u4e0b\u5747\u80fd\u4fdd\u6301\u6548\u7387\uff1b\u5168\u5c4b119.4%\u4e5f\u5728\u5b89\u5168\u8303\u56f4\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#e53935;line-height:1.7;padding-top:6px;border-top:1px dashed #eee\"><b style=\"color:#e53935\">\u65b9\u6848\uff1a<\/b>\u8212\u4eab160\u5916\u673a\u5bbd\u5e45\u8c03\u8282\u80fd\u529b\u5f3a\uff0c\u65e5\u5e38\u4f7f\u7528\u59cb\u7ec8\u8fd0\u884c\u5728<span style=\"color:#c62828;font-weight:700\">\u9ad8\u6548\u533a\u95f4<\/span>\uff0c\u9759\u97f3\u53c8\u7701\u7535\u3002<\/div>\n                  <\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/td>\n            <td style=\"padding:6px 5px;vertical-align:top;width:25%\">\n              <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;border:1px solid #e8e8e8;border-radius:12px;overflow:hidden;background:#fff\">\n                <tbody>\n                  <tr><td style=\"padding:16px 14px 10px;text-align:center\">\n                    <table cellpadding=\"0\" cellspacing=\"0\" style=\"margin:0 auto;border-collapse:collapse\"><tbody><tr><td style=\"width:44px;height:44px;background:#e8f5e9;border-radius:50%;text-align:center;font-size:22px;line-height:44px\">\ud83d\udcb0<\/td><\/tr><\/tbody><\/table>\n                    <div style=\"margin-top:8px;font-size:0.72rem;color:#2e7d32;background:#e8f5e9;display:inline-block;padding:2px 12px;border-radius:12px;font-weight:600;letter-spacing:0.5px\">\u9700\u6c42<\/div>\n                  <\/td><\/tr>\n                  <tr><td style=\"padding:0 14px 12px\">\n                    <div style=\"font-size:0.95rem;font-weight:800;color:#1a2332;margin-bottom:8px;line-height:1.4\">APF 5.80\u957f\u7ebf\u7701\u94b1<br>5~6\u5e74\u56de\u672c<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u73b0\u72b6\uff1a<\/b>\u7a7a\u8c03\u662f\u9ad8\u9891\u4f7f\u7528\u5bb6\u7535\uff0c\u6210\u90fd\u590f\u5b63\u5236\u51b7\u5b63\u957f\u8fbe4~5\u4e2a\u6708\uff0c\u6bcf\u5929\u5f008~12\u5c0f\u65f6\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#666;line-height:1.7;margin-bottom:6px\"><b style=\"color:#888\">\u4f9d\u636e\uff1a<\/b>APF 5.80\u65b0\u56fd\u6807\u4e00\u7ea7\u80fd\u6548\uff0c\u76f8\u6bd4\u8001\u4e09\u7ea7\u80fd\u6548\u673a\u578b\u6bcf\u5e74\u8282\u7701\u7535\u8d39\u7ea630%\u3002<\/div>\n                    <div style=\"font-size:0.78rem;color:#e53935;line-height:1.7;padding-top:6px;border-top:1px dashed #eee\"><b style=\"color:#e53935\">\u65b9\u6848\uff1a<\/b>\u9009\u8212\u4eab160\u4e00\u7ea7\u80fd\u6548\u673a\u578b\uff0c<span style=\"color:#2e7d32;font-weight:700\">5~6\u5e74\u7701\u4e0b\u7684\u7535\u8d39\u5c31\u80fd\u62b5\u6d88\u521d\u671f\u5dee\u4ef7<\/span>\uff0c\u8d8a\u7528\u8d8a\u5212\u7b97\u3002<\/div>\n                  <\/td><\/tr>\n                <\/tbody>\n              <\/table>\n            <\/td>\n          <\/tr><\/tbody>\n        <\/table>\n\n        <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;background:linear-gradient(135deg,#fffbf0,#fef6e4);border:2px dashed #d4b85a;border-radius:12px;overflow:hidden\">\n          <tbody><tr><td style=\"padding:16px 20px\">\n            <table cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;margin-bottom:12px\"><tbody><tr>\n              <td style=\"font-size:0.92rem;font-weight:800;color:#8a6d1f;letter-spacing:0.5px\">\ud83d\udcca \u65b9\u6848\u9884\u671f\u6548\u679c\uff08\u57fa\u4e8e\u914d\u7f6e\u6d4b\u7b97\uff09<\/td>\n              <td style=\"text-align:right;white-space:nowrap;padding-left:12px\">\n                <table cellpadding=\"0\" cellspacing=\"0\" style=\"border-collapse:collapse;display:inline-block\"><tbody><tr>\n                  <td style=\"background:#fff8e6;border:1px solid #e0c878;border-radius:14px;padding:3px 10px;font-size:0.72rem;color:#996500;font-weight:600;white-space:nowrap\">\u5236\u51b7\u6548\u679c\u2605\u2605\u2605\u2605\u2605<\/td>\n                  <td style=\"width:6px\"><\/td>\n                  <td style=\"background:#fff8e6;border:1px solid #e0c878;border-radius:14px;padding:3px 10px;font-size:0.72rem;color:#996500;font-weight:600;white-space:nowrap\">\u9759\u97f3\u8868\u73b0\u2605\u2605\u2605\u2605\u2605<\/td>\n                  <td style=\"width:6px\"><\/td>\n                  <td style=\"background:#fff8e6;border:1px solid #e0c878;border-radius:14px;padding:3px 10px;font-size:0.72rem;color:#996500;font-weight:600;white-space:nowrap\">\u64cd\u4f5c\u4f53\u9a8c\u2605\u2605\u2605\u2605\u2606<\/td>\n                  <td style=\"width:6px\"><\/td>\n                  <td style=\"background:#fff8e6;border:1px solid #e0c878;border-radius:14px;padding:3px 10px;font-size:0.72rem;color:#996500;font-weight:600;white-space:nowrap\">\u8282\u80fd\u7701\u7535\u2605\u2605\u2605\u2605\u2605<\/td>\n                <\/tr><\/tbody><\/table>\n              <\/td>\n            <\/tr><\/tbody><\/table>\n            <div style=\"font-size:0.87rem;color:#555;line-height:1.9\">\n              <p style=\"margin-bottom:6px\"><b style=\"color:#7a5a18\">\u590f\u5b63\u5236\u51b7\uff1a<\/b>\u6210\u90fd\u590f\u5b63\u95f7\u70ed\u9ad8\u6e7f\uff0c\u5e73\u5c42103.87\u33a1\u9700\u8981\u5145\u8db3\u7684\u5236\u51b7\u51b7\u91cf\u3002\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u914d\u7f6e50+22\u4e24\u53f0\u5185\u673a\uff087200W\uff09\uff0c\u5927\u516c\u533a\u5feb\u901f\u964d\u6e29\u65e0\u6b7b\u89d2\uff1b\u5bb6\u5ead\u5ba46300W\u3001\u4e3b\u53672500W\u3001\u6b21\u53672500W\u7cbe\u51c6\u5339\u914d\uff0c\u907f\u514d\u8fc7\u5927\u6216\u8fc7\u5c0f\u3002<\/p>\n              <p style=\"margin-bottom:6px\"><b style=\"color:#7a5a18\">\u8fd0\u884c\u5b89\u9759\uff1a<\/b>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5ba4\u5185\u673a\u4f4e\u566a\u8fd0\u884c\uff0c\u4e0d\u5f71\u54cd\u5bb6\u4eba\u4f11\u606f\u4e0e\u65e5\u5e38\u6d3b\u52a8\u3002\u5916\u673a\u653e\u7f6e\u5728\u5408\u7406\u4f4d\u7f6e\uff0c\u8fdc\u79bb\u5367\u5ba4\u7a97\u6237\u3002<\/p>\n              <p style=\"margin-bottom:6px\"><b style=\"color:#7a5a18\">\u7a33\u5b9a\u7701\u5fc3\uff1a<\/b>\u4e00\u62d6\u4e94\u591a\u8054\u673a\u7ed3\u6784\u7b80\u5355\u3001\u6545\u969c\u70b9\u5c11\uff0c\u65e5\u7acb\u539f\u5382\u54c1\u8d28+\u9f99\u8109\u6696\u901a\u4e13\u4e1a\u5b89\u88c5\u53cc\u91cd\u4fdd\u969c\uff0c\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\u3002<\/p>\n              <p style=\"margin-bottom:6px\"><b style=\"color:#7a5a18\">\u8282\u80fd\u7701\u7535\uff1a<\/b>RAS-160HRNAQ\u5916\u673aAPF\u8fbe5.80\uff08\u65b0\u56fd\u6807\u4e00\u7ea7\u80fd\u6548\uff09\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u6548\u7387\u9ad8\uff0c\u957f\u671f\u4f7f\u7528\u7535\u8d39\u53ef\u63a7\u3002<\/p>\n              <p style=\"margin-bottom:0\"><b style=\"color:#7a5a18\">\u4f7f\u7528\u573a\u666f\u5339\u914d\uff1a<\/b>\u767d\u5929\u5f00\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\uff0850+22\u540c\u5f007200W\uff09\u3001\u665a\u4e0a\u4e3b\u5367+\u6b21\u5367\u540c\u5f00\uff082500+2500=5000W\uff09\u3001\u6781\u7aef\u60c5\u51b5\u5168\u5c4b5\u53f0\u540c\u5f0018500W\uff0c\u8fde\u63a5\u7387119.4%\u4ece\u5bb9\u5e94\u5bf9\u5168\u5c4b\u540c\u5f00\u573a\u666f\u3002<\/p>\n            <\/div>\n          <\/td><\/tr><\/tbody>\n        <\/table>\n\n        <h3 class=\"card-title\" style=\"margin-top:22px\">\u5e73\u5c42\u540c\u9762\u79ef\u914d\u7f6e\u5bf9\u6807 \u00b7 103.87\u33a1\u600e\u4e48\u9009<\/h3>\n        <table class=\"info-table\">\n          <tbody><tr><th>\u5bf9\u6807\u65b9\u6848<\/th><th>\u914d\u7f6e\u8981\u70b9<\/th><th>\u8fde\u63a5\u7387<\/th><th>\u9002\u914d\u5224\u65ad<\/th><\/tr>\n            <tr><td><b class=\"bold-spec\">\u672c\u6848\u4f8b\u00b7\u8212\u4eab160\u4e00\u62d6\u4e94<\/b><\/td><td>RAS-160HRNAQ + 50\/22\/63\/25\/25 \u4e94\u5185\u673a<\/td><td>119.4%<\/td><td>\u2705 \u5236\u51b7\u5236\u70ed\u517c\u987e\uff0c\u5168\u5c4b\u540c\u5f00\u4ece\u5bb9\uff0c\u5e73\u5c42\u9996\u9009<\/td><\/tr>\n            <tr><td>\u8212\u4eab140\u4e00\u62d6\u4e94<\/td><td>RAS-140HRNAQ + \u540c\u4e94\u5185\u673a<\/td><td>132.1%<\/td><td>\u26a0\ufe0f \u8fde\u63a5\u7387\u504f\u9ad8\uff0c\u4ec5\u9002\u5408\u9762\u79ef\u66f4\u5c0f\u6216\u957f\u671f\u5c11\u4eba\u573a\u666f<\/td><\/tr>\n            <tr><td>\u683c\u529b\/\u7f8e\u7684 160 \u4e00\u62d6\u4e94<\/td><td>160\u5916\u673a + \u4e94\u5185\u673a<\/td><td>\u7ea6119%<\/td><td>\u26a0\ufe0f APF\u7ea64.8~5.2\u3001\u566a\u97f3\u7565\u9ad8\uff0c\u957f\u671f\u80fd\u8017\u4e0e\u9759\u97f3\u7565\u900a<\/td><\/tr>\n            <tr><td>\u98ce\u7ba1\u673a\u4e00\u62d6\u4e00\u00d75<\/td><td>5\u53f0\u5916\u673a\u72ec\u7acb<\/td><td>\u2014<\/td><td>\u274c \u5360\u6ee1\u9633\u53f0\u5916\u673a\u4f4d\u3001\u68c0\u4fee\u53e3\u591a\u3001\u7f8e\u89c2\u5dee<\/td><\/tr>\n          <\/tbody><\/table>\n        <p style=\"font-size:0.82rem;color:var(--text-gray);margin-top:8px\">\ud83d\udccc \u540c\u9762\u79ef\u5e73\u5c42\uff08\u7ea6100~120\u33a1\uff09\u5e38\u89c1\u914d\u7f6e\u6a2a\u5411\u5bf9\u6bd4\uff0c\u5e2e\u52a9\u4e1a\u4e3b\u6309\u5bb6\u5ead\u7ed3\u6784\u4e0e\u9884\u7b97\u5feb\u901f\u5b9a\u4f4d\uff1b\u672c\u6848\u4f8b\u56e0\u8986\u76d6\u4e24\u5927\u516c\u533a+\u4e24\u5367\u5ba4\u7684\u5168\u5c4b\u5236\u51b7\uff0c\u9501\u5b9a\u8212\u4eab160\u4e00\u62d6\u4e94\u3002<\/p>\n\n        <h3 class=\"card-title\" style=\"margin-top:22px\">\u672c\u697c\u76d8\u6237\u578b\u901a\u75c5 \u00b7 \u9488\u5bf9\u6027\u8bbe\u8ba1\u89e3\u8bfb<\/h3>\n        <div class=\"info-row\">\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u9ad8\u5c42\u98ce\u538b\u5f71\u54cd\u5916\u673a<\/div><div class=\"lbl\">\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u4e3a\u9ad8\u5c42\/\u5c0f\u9ad8\u5c42\u4f4f\u5b85\uff0c\u5916\u673a\u4f4d\u5b58\u5728\u98ce\u538b\u6270\u52a8 \u2192 \u8212\u4eab160\u5355\u98ce\u6247\u5916\u673a 770\u00d7980\u00d7360mm \u5b89\u88c5\u65f6\u52a0\u9632\u98ce\u56fa\u5b9a\u652f\u67b6\u4e0e\u51cf\u9707\u57ab\uff0c\u786e\u4fdd\u9ad8\u5c42\u5927\u98ce\u5929\u6c14\u8fd0\u884c\u7a33\u5b9a\u4e0d\u4f4d\u79fb\u3001\u4e0d\u5f02\u54cd<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u5916\u673a\u4f4d\u7a7a\u95f4\u53d7\u9650<\/div><div class=\"lbl\">\u8bbe\u5907\u5e73\u53f0\u5916\u673a\u4f4d\u72ed\u5c0f \u2192 \u4f18\u5148\u9009\u5355\u98ce\u6247\u7d27\u51d1\u673a\u578b\uff08\u800c\u975e\u53cc\u98ce\u6247\uff09\uff0c\u9884\u7559\u2265300mm\u6563\u70ed\u95f4\u8ddd\uff0c\u907f\u514d\u9ad8\u6e29\u964d\u9891<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u5927\u516c\u533a74.3\u33a1<\/div><div class=\"lbl\">\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f\u4e0e\u5bb6\u5ead\u5ba4\u4e3a\u4e24\u5927\u516c\u533a \u2192 \u7528 50+22 \u53cc\u5185\u673a + 63 \u5927\u5185\u673a\u5206\u533a\u9001\u51b7\uff0c\u907f\u514d\u5355\u53f0\u5185\u673a\u8fdc\u8ddd\u79bb\u9001\u98ce\u8870\u51cf\u3001\u51c9\u611f\u4e0d\u5747<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"val bold-spec\">\u5367\u5ba4\u63a7\u6e29\u72ec\u7acb<\/div><div class=\"lbl\">\u4e3b\u5367+\u6b21\u5367\u5206\u8bbe\u72ec\u7acb\u5185\u673a\uff08\u54042500W\uff09\u2192 \u6ee1\u8db3\u5206\u5ba4\u5dee\u5f02\u5316\u6e29\u5ea6\u9700\u6c42\uff0c\u591c\u95f4\u4e92\u4e0d\u5e72\u6270<\/div><\/div>\n        <\/div>\n\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u9f99\u8109\u4e13\u4e1a\u4e3b\u5f20<\/h3>\n        <div class=\"advantage-grid\">\n          <div class=\"advantage-card\"><div class=\"adv-name\">1. \u6570\u636e\u8bf4\u8bdd<\/div><div class=\"adv-desc\">\u4e0d\u62cd\u8111\u888b\uff0c\u9010\u623f\u95f4\u7b97\u51b7\u8d1f\u8377\u3002<\/div><button class=\"adv-expand\" onclick=\"toggleAdv(this)\">\u5c55\u5f00\u8be6\u60c5<\/button><div class=\"adv-full\">\u6bcf\u5957\u65b9\u6848\u90fd\u57fa\u4e8eGB 50736-2012\u56fd\u6807\u505a\u9010\u623f\u95f4\u51b7\u8d1f\u8377\u6d4b\u7b97\uff0c\u7ed3\u5408\u73b0\u573a\u52d8\u6d4b\u7684\u9762\u79ef\u3001\u671d\u5411\u3001\u4fdd\u6e29\u6761\u4ef6\u3001\u4f7f\u7528\u4e60\u60ef\uff0c\u7528\u6570\u636e\u51b3\u5b9a\u5185\u673a\u5bb9\u91cf\uff0c\u800c\u4e0d\u662f\u51ed\u611f\u89c9\"\u5dee\u4e0d\u591a\u5c31\u884c\"\u3002<\/div><\/div>\n          <div class=\"advantage-card\"><div class=\"adv-name\">2. \u8fde\u63a5\u7387\u6709\u5ea6<\/div><div class=\"adv-desc\">119.4%\u8fde\u63a5\u7387\uff0c\u5b89\u5168\u53c8\u9884\u7559\u4f59\u91cf\u3002<\/div><button class=\"adv-expand\" onclick=\"toggleAdv(this)\">\u5c55\u5f00\u8be6\u60c5<\/button><div class=\"adv-full\">\u8fde\u63a5\u7387\u4e0d\u662f\u8d8a\u9ad8\u8d8a\u597d\u4e5f\u4e0d\u662f\u8d8a\u4f4e\u8d8a\u597d\u3002119.4%\u4fdd\u8bc1\u5168\u5c4b5\u53f0\u540c\u5f00\u65f6\u5236\u51b7\u91cf\u5145\u88d5\uff0c\u540c\u65f6\u65e5\u5e38\u90e8\u5206\u8d1f\u8377\u8fd0\u884c\u65f6\u5916\u673a\u5728\u9ad8\u6548\u7387\u533a\u95f4\u5de5\u4f5c\u6700\u7701\u7535\u3002\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u7684\u5b89\u5168\u533a\u95f4\u5185\uff0c\u653e\u5fc3\u7528\u3002<\/div><\/div>\n          <div class=\"advantage-card\"><div class=\"adv-name\">3. \u80fd\u6548\u4e3a\u738b<\/div><div class=\"adv-desc\">APF 5.80\u4e00\u7ea7\u80fd\u6548\uff0c\u957f\u671f\u7701\u94b1\u3002<\/div><button class=\"adv-expand\" onclick=\"toggleAdv(this)\">\u5c55\u5f00\u8be6\u60c5<\/button><div class=\"adv-full\">\u7a7a\u8c03\u662f\u4f7f\u7528\u9891\u7387\u6700\u9ad8\u7684\u5bb6\u7535\u4e4b\u4e00\uff0c\u590f\u5b63\u6bcf\u5929\u5f008~12\u5c0f\u65f6\u3002APF 5.80\u610f\u5473\u7740\u540c\u6837\u7684\u5236\u51b7\u91cf\u6d88\u8017\u66f4\u5c11\u7535\u529b\u3002\u4ee5\u6210\u90fd\u7535\u4ef7\u8ba1\u7b97\uff0c\u4f7f\u75285\u5e74\u4ee5\u4e0a\u8282\u7701\u7684\u7535\u8d39\u5c31\u80fd\u5f25\u8865\u9ad8\u80fd\u6548\u673a\u578b\u7684\u521d\u671f\u5dee\u4ef7\u3002<\/div><\/div>\n          <div class=\"advantage-card\"><div class=\"adv-name\">4. 22\u5e74\u672c\u571f\u53e3\u7891<\/div><div class=\"adv-desc\">\u6210\u90fd\u672c\u5730\u6848\u4f8b\u6570\u636e\u5e93\uff0c\u8001\u5ba2\u6237\u590d\u8d2d\u7387\u9ad8\u3002<\/div><button class=\"adv-expand\" onclick=\"toggleAdv(this)\">\u5c55\u5f00\u8be6\u60c5<\/button><div class=\"adv-full\">\u9f99\u8109\u6696\u901a\u6df1\u8015\u6210\u90fd\u5e02\u573a22\u5e74\uff0c\u65e5\u7acb\u5b98\u65b9\u94bb\u77f3\u5b89\u88c5\u5546\u3002\u65bd\u5de5\u5168\u7a0b\u62cd\u7167\u7559\u6863\uff0c\u5173\u952e\u8282\u70b9\u5f71\u50cf\u53ef\u67e5\u3002\u4ee5\u4e13\u4e1a\u548c\u771f\u8bda\u8d62\u5f97\u5ba2\u6237\u4fe1\u4efb\uff0c\u5927\u91cf\u8001\u5ba2\u6237\u4ecb\u7ecd\u65b0\u5ba2\u6237\u3002<\/div><\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u98ce\u9669\u544a\u77e5<\/h3>\n        <table class=\"risk-table\">\n          <tbody><tr><th>\u98ce\u9669\u9879<\/th><th>\u98ce\u9669\u7b49\u7ea7<\/th><th>\u9f99\u8109\u5e94\u5bf9<\/th><\/tr>\n          <tr><td>\u540a\u9876\u9ad8\u5ea6\u635f\u5931<\/td><td><span class=\"risk-level risk-mid\">\u4e2d<\/span><\/td><td>\u5c42\u9ad8\u7ea62.9\u7c73\u8db3\u591f\uff0c\u5185\u673a\u539a\u5ea6192mm\uff0c\u5c40\u90e8\u540a\u9876\u727a\u7272\u5c11\u91cf\u5c42\u9ad8\u6362\u53d6\u7f8e\u89c2\u4e0e\u8212\u9002<\/td><\/tr>\n          <tr><td>\u5916\u673a\u4f4d\u6563\u70ed<\/td><td><span class=\"risk-level risk-mid\">\u4e2d<\/span><\/td><td>\u5355\u98ce\u6247\u5916\u673a\u9700\u9884\u7559\u8db3\u591f\u6563\u70ed\u7a7a\u95f4\uff08\u2265300mm\uff09\uff0c\u5b89\u88c5\u524d\u786e\u8ba4\u5916\u673a\u4f4d\u5c3a\u5bf8\u4e0e\u901a\u98ce\u6761\u4ef6<\/td><\/tr>\n          <tr><td>\u51b7\u51dd\u6c34\u6392\u6c34<\/td><td><span class=\"risk-level risk-low\">\u4f4e<\/span><\/td><td>\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22651%+\u704c\u6c34\u8bd5\u9a8c\u786e\u8ba4\uff0c\u5b89\u88c5\u8d28\u4fdd\u7ec8\u8eab\u515c\u5e95<\/td><\/tr>\n          <tr><td>\u5185\u673a\u566a\u97f3<\/td><td><span class=\"risk-level risk-low\">\u4f4e<\/span><\/td><td>\u8212\u4eab\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f3\u4f4e\uff0c\u5367\u5ba4\u9009\u62e9\u5408\u9002\u6863\u4f4d\u51e0\u4e4e\u65e0\u611f<\/td><\/tr>\n          <tr><td>\u4fdd\u538b\u6cc4\u6f0f<\/td><td><span class=\"risk-level risk-low\">\u4f4e<\/span><\/td><td>\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5+24h\u4fdd\u538b\u6d4b\u8bd5+\u5f71\u50cf\u7559\u6863\uff0c\u6f0f\u7387\u4e3a\u96f6<\/td><\/tr>\n          <tr><td>\u897f\u6652\u5236\u51b7\u8870\u51cf<\/td><td><span class=\"risk-level risk-mid\">\u4e2d<\/span><\/td><td>\u672c\u6848\u5ba2\u9910\u5385\u4ee5\u4e1c\u5411\u4e3a\u4e3b\u3001\u897f\u6652\u5f71\u54cd\u6709\u9650\uff1b\u82e5\u623f\u95f4\u897f\u6652\u5f3a\uff0c\u6309180W\/\u33a1\u57fa\u51c6\u5df2\u9884\u7559\u7ea610%\u4f59\u91cf<\/td><\/tr>\n          <tr><td>\u7535\u538b\u6ce2\u52a8<\/td><td><span class=\"risk-level risk-low\">\u4f4e<\/span><\/td><td>\u65e5\u7acb\u5bbd\u7535\u538b\u8bbe\u8ba1\uff08\u5236\u51b7-5~59\u2103\u8fd0\u884c\uff09\uff0c\u914d\u5957\u6f0f\u4fdd\u4e0e\u7a33\u538b\uff0c\u5f02\u5e38\u81ea\u52a8\u4fdd\u62a4\u505c\u673a<\/td><\/tr>\n        <\/tbody><\/table>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u6696\u901a\u8d34\u58eb<\/h3>\n        <div class=\"note-skeleton\">\ud83d\udca1 <strong>\u4f7f\u7528\u8d34\u58eb<\/strong><br>\u2460 <strong>\u590f\u5b63\u9996\u6b21\u5f00\u673a\uff1a<\/strong>\u5efa\u8bae\u5148\u5f00\u300c\u9001\u98ce\u300d\u6a21\u5f0f\u8fd0\u884c10~15\u5206\u949f\u518d\u5207\u6362\u5236\u51b7\uff0c\u8ba9\u7ba1\u8def\u9884\u70ed\u51cf\u5c11\u538b\u7f29\u673a\u51b2\u51fb<br>\u2461 <strong>\u65e5\u5e38\u6e29\u5ea6\u8bbe\u5b9a\uff1a<\/strong>\u5efa\u8bae\u5236\u51b7\u8bbe26\u2103\uff08\u6bcf\u964d\u4f4e1\u2103\u589e\u52a0\u7ea67%\u80fd\u8017\uff09\uff0c\u914d\u5408\u300c\u9664\u6e7f\u300d\u6a21\u5f0f\u4f53\u611f\u66f4\u8212\u9002<br>\u2462 <strong>\u6ee4\u7f51\u6e05\u6d01\uff1a<\/strong>\u6bcf2~3\u4e2a\u6708\u53d6\u51fa\u6ee4\u7f51\u7528\u6e05\u6c34\u6216\u5438\u5c18\u5668\u6e05\u6d01\uff0c\u5835\u585e\u7684\u6ee4\u7f51\u4f1a\u5927\u5e45\u589e\u52a0\u80fd\u8017\u5e76\u5f71\u54cd\u6548\u679c<br>\u2463 <strong>\u5916\u51fa\u79bb\u5bb6\uff1a<\/strong>\u4e0d\u5efa\u8bae\u5b8c\u5168\u5173\u95ed\u7a7a\u8c03\uff0c\u53ef\u8c03\u81f328~30\u2103\u4f4e\u901f\u8fd0\u884c\uff0c\u56de\u5bb6\u540e\u518d\u8c03\u4f4e\uff0c\u6bd4\u4ece\u96f6\u964d\u6e29\u66f4\u7701\u7535<br>\u2464 <strong>\u6362\u5b63\u4fdd\u517b\uff1a<\/strong>\u6625\u79cb\u5b63\u8282\u6bcf\u6708\u5f00\u673a\u8fd0\u884c10~15\u5206\u949f\u9632\u6b62\u538b\u7f29\u673a\u5185\u90e8\u96f6\u4ef6\u8001\u5316<br>\u2465 <strong>\u7ebf\u63a7\u5668\u7535\u6c60\uff1a<\/strong>\u65e0\u7ebf\u7ebf\u63a7\u5668\u5efa\u8bae\u6bcf\u5e74\u66f4\u6362\u4e00\u6b21\u7535\u6c60\uff0c\u907f\u514d\u7a81\u7136\u6ca1\u7535\u5bfc\u81f4\u65e0\u6cd5\u64cd\u4f5c<br>\u2466 <strong>\u51ac\u5b63\u5236\u70ed\uff1a<\/strong>\u6210\u90fd\u6e7f\u51b7\uff0c\u5236\u70ed\u5efa\u8bae\u8bbe20~22\u2103\u5e76\u5f00\u542f\"\u9632\u51b7\u98ce\"\u529f\u80fd\uff0c\u521a\u5f00\u673a\u51fa\u98ce\u6e29\u5347\u6709\u77ed\u6682\u5ef6\u8fdf\u5c5e\u6b63\u5e38<br>\u2467 <strong>\u957f\u671f\u7a7a\u7f6e\uff1a<\/strong>\u8d85\u8fc71\u4e2a\u6708\u4e0d\u4f4f\u4eba\uff0c\u5efa\u8bae\u5173\u95ed\u7a7a\u8c03\u603b\u7535\u6e90\u5e76\u6392\u7a7a\u51b7\u51dd\u6c34\uff1b\u5f52\u6765\u540e\u5148\u9001\u98ce10\u5206\u949f\u518d\u5207\u6362\u5236\u51b7<\/div>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u5ba2\u6237\u6c9f\u901a\u5b9e\u5f55\uff08\u914d\u7f6e\u5355\u9010\u9879\u6838\u5bf9\uff09<\/h3>\n        <div class=\"review-card\">\n          <p><strong>\u8521\u8001\u5e08\uff08\u54a8\u8be2\uff09\uff1a<\/strong>\"\u6211\u770b\u4e86\u4f60\u4eec\u7ed9\u6211\u7684\u914d\u7f6e\u5355\uff0c\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1\u914d\u4e8650+22\u4e24\u53f0\u5185\u673a\u51717200W\uff0c\u8fd9\u4e2a\u662f\u600e\u4e48\u7b97\u51fa\u6765\u7684\uff1f\"<\/p>\n        <\/div>\n        <div class=\"review-card\">\n          <p><strong>\u4f59\u6653\u73b2\uff08\u65b9\u6848\u987e\u95ee\uff09\uff1a<\/strong>\"\u6309GB 50736\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\uff0c\u8bbe\u8ba1\u57fa\u51c6150W\/\u33a1\uff0c\u60a8\u5bb6\u5927\u516c\u533a\u51b7\u6307\u6807166W\/\u33a1\u5728\u5408\u7406\u533a\u95f4\uff1b\u4e24\u53f0\u5185\u673a\u5206\u533a\u63a7\u6e29\u66f4\u7075\u6d3b\uff0c\u5355\u53f0\u4e5f\u4e0d\u4f1a\u8fdc\u8ddd\u79bb\u9001\u98ce\u8870\u51cf\u3002\"<\/p>\n        <\/div>\n        <div class=\"review-card\">\n          <p><strong>\u4f59\u6653\u73b2\uff08\u65b9\u6848\u8f93\u51fa\uff09\uff1a<\/strong>\"\u63a8\u8350\u8212\u4eab160\u4e00\u62d6\u4e94\uff0cRAS-160HRNAQ\u5355\u98ce\u6247\u5916\u673a\uff0c5\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W\u5339\u914d15500W\u5916\u673a\uff0c\u8fde\u63a5\u7387119.4%\uff0cAPF5.80\uff0c\u603b\u9020\u4ef7\u542b\u5b89\u88c5\u8f85\u6750\u4ee5\u52d8\u6d4b\u540e\u660e\u7ec6\u4e3a\u51c6\u3002\"<\/p>\n        <\/div>\n        <div class=\"review-card\">\n          <p><strong>\u8521\u8001\u5e08\uff08\u6838\u5bf9\u8fde\u63a5\u7387\uff09\uff1a<\/strong>\"\u8fde\u63a5\u7387119.4%\u548c\u522b\u7684\u5bb6\u8bf4\u7684130%\u591a\u6709\u4ec0\u4e48\u533a\u522b\uff1f\"<br><strong>\u4f59\u6653\u73b2\uff1a<\/strong>\"\u8fde\u63a5\u7387\u4e0d\u662f\u8d8a\u9ad8\u8d8a\u597d\uff0c119.4%\u5728\u65e5\u7acb\u5b89\u5168\u7ecf\u6d4e\u533a\u95f4\uff0c\u5168\u5c4b5\u53f0\u540c\u5f00\u4e5f\u591f\uff0c\u65e5\u5e38\u90e8\u5206\u8d1f\u8377\u8fd0\u884c\u66f4\u7701\u7535\u3002\u9ad8\u4e8e130%\u53cd\u800c\u957f\u671f\u6ee1\u8d1f\u8377\u504f\u591a\u3002\"<\/p>\n        <\/div>\n        <div class=\"review-card\">\n          <p><strong>\u8521\u8001\u5e08\uff08\u5b9a\u7248\uff09\uff1a<\/strong>\"\u884c\uff0c\u914d\u7f6e\u5355\u6211\u4e00\u9879\u9879\u5bf9\u8fc7\u4e86\uff0c\u9762\u79ef\u3001\u51b7\u6307\u6807\u3001\u578b\u53f7\u90fd\u6e05\u695a\uff0c\u5c31\u6309\u8fd9\u4e2a\u6765\u3002\"<br><strong>\u4f59\u6653\u73b2\uff1a<\/strong>\"\u597d\u561e\uff0c\u6211\u5b89\u6392\u51fa\u56fe\u3001\u7ea6\u5e08\u5085\u4e0a\u95e8\u52d8\u6d4b\u65bd\u5de5\uff0c\u5168\u7a0b\u76f4\u8425\u3002\"<\/p>\n        <\/div>\n        <p style=\"font-size:0.82rem;color:var(--text-gray);margin-top:12px\">\ud83d\udcac \u4ee5\u4e0a\u4e3a\u6c9f\u901a\u8fc7\u7a0b\u4e2d\u7684\u5173\u952e\u8282\u70b9\u6458\u5f55\uff0c\u4f53\u73b0\u5ba2\u6237\u4ece\"\u914d\u7f6e\u5355\u600e\u4e48\u7b97\u7684\"\u7684\u7591\u95ee\uff0c\u5230\u7406\u89e3\"\u8fde\u63a5\u7387119.4%\u5b89\u5168\u7ecf\u6d4e\"\u3001\u518d\u5230\u9010\u9879\u6838\u5bf9\u5e76\u6210\u4ea4\u7684\u5b8c\u6574\u51b3\u7b56\u94fe\u8def\u3002<\/p>\n      <\/div>\n\n      <div class=\"content-card slider-card\">\n        <h3 class=\"card-title\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u6696\u901a\u95ee\u7b54<\/h3>\n        <div class=\"faq-item\">\n          <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u5e73\u5c42\u88c5\u65e5\u7acb\u8212\u4eab160\u6574\u5957\u843d\u5730\u591a\u5c11\u94b1\uff1f<\/div>\n          <div class=\"faq-a\"><p>\u672c\u6237\u578b\u91c7\u7528\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ\u4e00\u62d6\u4e94\uff08\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f 50+22\u51717200W + \u5bb6\u5ead\u5ba463 6300W + \u4e3b\u536725 2500W + \u6b21\u536725 2500W\uff0c\u603b\u5236\u51b7\u91cf18500W\uff09\u3002\u5177\u4f53\u9020\u4ef7\u56e0\u7ba1\u7ebf\u957f\u5ea6\u3001\u73b0\u573a\u6761\u4ef6\u800c\u5f02\uff0c\u9700\u73b0\u573a\u52d8\u6d4b\u540e\u51fa\u5177\u660e\u7ec6\u62a5\u4ef7\u3002\u9f99\u8109\u6696\u901a\u627f\u8bfa\u96f6\u589e\u9879\uff0c\u5408\u540c\u4ef7\u5373\u6700\u7ec8\u4ef7\u3002<\/p><\/div>\n        <\/div>\n        <div class=\"faq-item\">\n          <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u8fde\u63a5\u7387119.4%\u4f1a\u4e0d\u4f1a\u5bfc\u81f4\u5236\u51b7\u6548\u679c\u4e0d\u597d\uff1f<\/div>\n          <div class=\"faq-a\"><p>\u4e0d\u4f1a\u3002\u8fde\u63a5\u7387119.4%\u5728\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u7684\u5b89\u5168\u7ecf\u6d4e\u8303\u56f4\u5185\uff08\u901a\u5e38\u5141\u8bb8130%~150%\uff09\u3002\u5173\u952e\u662f\u7406\u89e3\u300c\u8fde\u63a5\u7387\u300d\u7684\u5b9a\u4e49\uff1a\u5b83\u6307\u7684\u662f5\u53f0\u5185\u673a\u7684<b class=\"bold-spec\">\u94ed\u724c\u5bb9\u91cf\u4e4b\u548c<\/b>\u8d85\u8fc7\u5916\u673a\u5bb9\u91cf\uff0c\u4f46\u5b9e\u9645\u4f7f\u7528\u4e2d\u5f88\u5c11\u51fa\u73b05\u53f0\u540c\u65f6\u6ee1\u8d1f\u8377\u8fd0\u884c\u7684\u60c5\u51b5\u3002\u65e5\u5e38\u4f7f\u7528\uff08\u767d\u5929\u516c\u533a\u6216\u665a\u4e0a\u5367\u5ba4\uff09\u5916\u673a\u8d1f\u8f7d\u7387\u7ea632%~47%\uff0c\u53cd\u800c\u8fd0\u884c\u5728\u6700\u7701\u7535\u7684\u9ad8\u6548\u533a\u95f4\u3002\u5373\u4f7f\u6781\u7aef\u60c5\u51b5\u4e0b\u5168\u5c4b\u540c\u5f00\uff0c119.4%\u7684\u8fde\u63a5\u4e5f\u80fd\u6ee1\u8db3\u5236\u51b7\u9700\u6c42\u3002<\/p><\/div>\n        <\/div>\n        <div class=\"faq-item\">\n          <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u5e73\u5c42103.87\u33a1\u7528\u8212\u4eab160\u4f1a\u4e0d\u4f1a\u592a\u5927\/\u592a\u5c0f\uff1f<\/div>\n          <div class=\"faq-a\"><p>\u6b63\u597d\u5408\u9002\uff0c\u4e14\u9884\u7559\u4e86\u5168\u5c4b\u540c\u5f00\u4f59\u91cf\u3002\u4ece\u6570\u636e\u770b\uff1a5\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W\uff0c\u5916\u673a15500W\uff0c\u8986\u76d6\u7ea6103.87\u33a1\u7a7a\u8c03\u9762\u79ef\uff08\u5e73\u5747178W\/\u33a1\uff09\u3002\u4e24\u5927\u516c\u533a+\u4e24\u5367\u5ba4\u5168\u5c4b\u540c\u5f00\u65f6119.4%\u8fde\u63a5\u7387\u4e5f\u80fd\u4ece\u5bb9\u5e94\u5bf9\uff0c\u662f\u5e73\u5c42\u6237\u578b\u7684\u7a33\u59a5\u9009\u62e9\u3002<\/p><\/div>\n        <\/div>\n        <div class=\"faq-item\">\n          <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u65e5\u7acb\u8212\u4eab160\u548c\u683c\u529b\/\u7f8e\u7684160\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/div>\n          <div class=\"faq-a\"><p>\u6838\u5fc3\u533a\u522b\u5728\u4e09\u70b9\uff1a<b class=\"bold-spec\">\u2460 APF\u80fd\u6548<\/b>\u8212\u4eab160\u8fbe5.80\uff08\u65b0\u56fd\u6807\u4e00\u7ea7\uff09\uff0c\u540c\u7ea7\u54c1\u724c\u7ea64.8~5.2\uff08\u4e8c\u7ea7\u6216\u4e09\u7ea7\uff09\uff0c\u957f\u671f\u7535\u8d39\u5dee\u8ddd\u660e\u663e\uff1b<b class=\"bold-spec\">\u2461 \u566a\u97f3\u63a7\u5236<\/b>\u8212\u4eab\u5916\u673a54dB(A)\u5728\u540c\u7ea7\u4e2d\u5c5e\u8f83\u4f4e\u6c34\u5e73\uff0c\u5951\u5408\u8521\u8001\u5e08\"\u9759\u97f3\"\u8bc9\u6c42\uff1b<b class=\"bold-spec\">\u2462 \u552e\u540e\u4fdd\u969c<\/b>\u9f99\u8109\u6696\u901a\u4f5c\u4e3a\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\uff0c\u5382\u5bb6\u76f4\u4fdd+\u5b89\u88c5\u8d28\u4fdd\u7684\u53cc\u91cd\u4fdd\u969c\u662f\u5f88\u591a\u6e20\u9053\u5546\u65e0\u6cd5\u63d0\u4f9b\u7684\u3002<\/p><\/div>\n        <\/div>\n        <div class=\"faq-item\">\n          <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u4ee5\u540e\u60f3\u52a0\u65b0\u98ce\u6216\u8005\u5730\u6696\u8fd8\u80fd\u52a0\u88c5\u5417\uff1f<\/div>\n          <div class=\"faq-a\"><p>\u53ef\u4ee5\u3002\u4e2d\u592e\u7a7a\u8c03\u7ba1\u9053\u548c\u65b0\u98ce\/\u5730\u6696\u7ba1\u9053\u662f\u72ec\u7acb\u7684\u7cfb\u7edf\uff0c\u4e92\u4e0d\u5f71\u54cd\u3002\u5982\u679c\u540e\u671f\u60f3\u52a0\u88c5\u65b0\u98ce\u7cfb\u7edf\uff0c\u53ea\u9700\u989d\u5916\u5e03\u7f6e\u65b0\u98ce\u7ba1\u8def\u4e0e\u4e3b\u673a\u5373\u53ef\uff0c\u539f\u6709\u7a7a\u8c03\u7cfb\u7edf\u65e0\u9700\u6539\u52a8\u3002\u540c\u7406\uff0c\u5982\u540e\u7eed\u6709\u5730\u6696\u9700\u6c42\u4e5f\u53ef\u72ec\u7acb\u52a0\u88c5\u3002\u5efa\u8bae\u5728\u672c\u6b21\u88c5\u4fee\u9636\u6bb5\u9884\u7559\u597d\u65b0\u98ce\u7ba1\u8def\u7684\u7a7f\u6881\u5b54\/\u7a7f\u5899\u5b54\uff08\u76f4\u5f84\u7ea6100~150mm\uff09\uff0c\u540e\u671f\u52a0\u88c5\u6210\u672c\u66f4\u4f4e\u3001\u65bd\u5de5\u66f4\u4fbf\u6377\u3002<\/p><\/div>\n        <\/div>\n      <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"step-section\" id=\"faq\" style=\"padding-top:20px\">\n    <h2 class=\"step-head\" id=\"s5-faq\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u6696\u901a \u00b7 \u5e38\u89c1\u95ee\u9898 FAQ<\/h2>\n    <div class=\"content-card\">\n      <div class=\"faq-item\">\n        <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u5e73\u5c42\u88c5\u65e5\u7acb\u8212\u4eab160\u6574\u5957\u843d\u5730\u591a\u5c11\u94b1\uff1f<\/div>\n        <div class=\"faq-a\"><p>\u6574\u5957\u542b\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ\u5916\u673a1\u53f0 + 5\u53f0\u5185\u673a\uff08RPIZ-50FSNAQD\/P + RPIZ-22FSNAQD\/P + RPIZ-63FSNAQD\/P + RPIZ-25FSNAQD\/P + RPIZ-25FSNAQD\/P\uff09+ \u7ebf\u63a7\u56685\u4e2a + \u51b7\u5a92\u94dc\u7ba1\u53ca\u8f85\u6750\u3002\u5177\u4f53\u9020\u4ef7\u56e0\u7ba1\u7ebf\u957f\u5ea6\u3001\u73b0\u573a\u6761\u4ef6\u800c\u5f02\uff0c\u9700\u73b0\u573a\u52d8\u6d4b\u540e\u51fa\u5177\u660e\u7ec6\u62a5\u4ef7\u3002\u9f99\u8109\u6696\u901a\u627f\u8bfa\u96f6\u589e\u9879\uff0c\u5408\u540c\u4ef7\u5373\u6700\u7ec8\u4ef7\u3002<\/p><\/div>\n      <\/div>\n      <div class=\"faq-item\">\n        <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u5e73\u5c42103.87\u33a1\u7528\u8212\u4eab160\u4e00\u62d6\u4e94\u591f\u5417\uff1f<\/div>\n        <div class=\"faq-a\"><p>\u5b8c\u5168\u8db3\u591f\u4e14\u9884\u7559\u4f59\u91cf\u30025\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W\uff0c\u8212\u4eab160\u5916\u673a\u989d\u5b9a\u5236\u51b715500W\uff0c\u8fde\u63a5\u7387119.4%\u5728\u65e5\u7acb\u5b89\u5168\u7ecf\u6d4e\u8303\u56f4\u5185\u3002\u4e24\u5927\u516c\u533a+\u4e24\u5367\u5ba4\u5168\u5c4b\u540c\u5f00\u4e5f\u80fd\u6ee1\u8db3\u5236\u51b7\u9700\u6c42\u3002<\/p><\/div>\n      <\/div>\n      <div class=\"faq-item\">\n        <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u65e5\u7acb\u8212\u4eab160\u7684APF 5.80\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u80fd\u7701\u591a\u5c11\u7535\uff1f<\/div>\n        <div class=\"faq-a\"><p>APF\uff08\u5168\u5e74\u80fd\u6e90\u6d88\u8017\u6548\u7387\uff095.80\u662f\u65b0\u56fd\u6807\u4e00\u7ea7\u80fd\u6548\uff0c\u6570\u503c\u8d8a\u9ad8\u8d8a\u7701\u7535\u3002\u4ee5\u6210\u90fd\u590f\u5b63\u5236\u51b7\u5b634~5\u4e2a\u6708\u3001\u65e5\u5747\u8fd0\u884c8\u5c0f\u65f6\u4f30\u7b97\uff0c\u76f8\u6bd4APF 4.0\u7684\u8001\u4e09\u7ea7\u80fd\u6548\u673a\u578b\uff0c\u6bcf\u5e74\u53ef\u8282\u7701\u7535\u8d39\u7ea6<strong style=\"color:#c00\">30%<\/strong>\u3002\u4f7f\u75285~6\u5e74\u7684\u7d2f\u8ba1\u8282\u7701\u7535\u8d39\u5373\u53ef\u62b5\u6d88\u9ad8\u80fd\u6548\u673a\u578b\u7684\u521d\u671f\u5dee\u4ef7\u3002<\/p><\/div>\n      <\/div>\n      <div class=\"faq-item\">\n        <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u548c\u6302\u673a\u67dc\u673a\u6bd4\u54ea\u4e2a\u597d\uff1f<\/div>\n        <div class=\"faq-a\"><p>\u5e73\u5c42\u6237\u578b\u5f3a\u70c8\u5efa\u8bae\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u3002\u4f18\u52bf\uff1a\u2460 \u4ec51\u53f0\u5916\u673a\u4e0d\u5360\u7a7a\u95f4 \u2461 \u5185\u85cf\u5f0f\u5b89\u88c5\u7f8e\u89c2\u5927\u65b9 \u2462 \u5206\u5ba4\u6e29\u63a7\u5404\u623f\u95f4\u72ec\u7acb \u2463 \u8fd0\u884c\u66f4\u5b89\u9759 \u2464 \u957f\u671f\u80fd\u8017\u66f4\u4f4e\u3002\u6302\u673a\u67dc\u673a\u9002\u5408\u51fa\u79df\u623f\u6216\u9884\u7b97\u6781\u6709\u9650\u7684\u573a\u666f\uff0c\u81ea\u4f4f\u5e73\u5c42\u9009\u4e2d\u592e\u7a7a\u8c03\u4f53\u9a8c\u5dee\u8ddd\u975e\u5e38\u5927\u3002<\/p><\/div>\n      <\/div>\n      <div class=\"faq-item\">\n        <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u9f99\u8109\u6696\u901a\u7684\u5b89\u88c5\u8d28\u4fdd\u591a\u4e45\uff1f\u51fa\u4e86\u95ee\u9898\u600e\u4e48\u529e\uff1f<\/div>\n        <div class=\"faq-a\"><p>\u9f99\u8109\u6696\u901a\u627f\u8bfa\uff1a<b class=\"bold-spec\">\u5b89\u88c5\u90e8\u5206\u8d28\u4fdd<\/b>\uff08\u975e\u4eba\u4e3a\u635f\u574f\u514d\u8d39\u7ef4\u4fee\uff09\uff0c\u65e5\u7acb\u6574\u673a\u4eab\u53d7\u539f\u5382\u4fdd\u4fee\uff08\u4e00\u822c\u4e3a3~5\u5e74\uff0c\u89c6\u5177\u4f53\u578b\u53f7\u653f\u7b56\uff09\u3002\u552e\u540e\u6d41\u7a0b\uff1a\u62e8\u6253\u552e\u540e\u4e13\u7ebf \u2192 24\u5c0f\u65f6\u5185\u54cd\u5e94 \u2192 \u6210\u90fd\u5e02\u533a48\u5c0f\u65f6\u4e0a\u95e8\u3002\u6b64\u5916\u8fd8\u670910\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff0c\u56e0\u8bbe\u8ba1\u5b89\u88c5\u5bfc\u81f4\u7684\u80fd\u8017\u5f02\u5e38\u514d\u8d39\u8bca\u65ad\u8c03\u6574\u3002<\/p><\/div>\n      <\/div>\n      <div class=\"faq-item\">\n        <div class=\"faq-q\" onclick=\"toggleFaq(this)\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8fd9\u5957\u65b9\u6848\u540e\u671f\u52a0\u5730\u6696\u6216\u65b0\u98ce\u65b9\u4fbf\u5417\uff1f<\/div>\n        <div class=\"faq-a\"><p>\u975e\u5e38\u65b9\u4fbf\u3002\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u3001\u5730\u6696\u4e09\u8005\u7ba1\u9053\u5b8c\u5168\u72ec\u7acb\uff0c\u4e92\u4e0d\u5e72\u6270\u3002\u540e\u671f\u52a0\u88c5\u53ea\u9700\u65b0\u589e\u5bf9\u5e94\u7cfb\u7edf\u7684\u7ba1\u8def\u4e0e\u8bbe\u5907\u5373\u53ef\uff0c\u539f\u6709\u7a7a\u8c03\u65e0\u9700\u4efb\u4f55\u6539\u52a8\u3002\u5efa\u8bae\u88c5\u4fee\u9636\u6bb5\u63d0\u524d\u9884\u7559\u65b0\u98ce\u7a7f\u6881\u5b54\uff08\u03c6100~150mm\uff09\uff0c\u540e\u671f\u52a0\u88c5\u6210\u672c\u6700\u4f4e\u3002<\/p><\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <div style=\"max-width:1400px;margin:0 auto;padding:10px 24px 20px\">\n    <div class=\"card-title\" style=\"margin-bottom:14px\">\u76f8\u5173\u6848\u4f8b\u4e0e\u4e13\u9898\u5bfc\u822a<\/div>\n    <div class=\"link-grid\">\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\"><div class=\"lc-title\">\u65e5\u7acb EX\u00b7\u8212\u4eab\u7cfb\u5217 \u00b7 \u5b8c\u6574\u4ea7\u54c1\u624b\u518c<\/div><div class=\"lc-desc\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\u4e0e\u6280\u672f\u53c2\u6570<\/div><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/guide\/air-conditioner-guide.html\"><div class=\"lc-title\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009\uff1f\u5b8c\u6574\u9009\u578b\u6307\u5357<\/div><div class=\"lc-desc\">\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u5168\u6d41\u7a0b\u4e0e\u907f\u5751\u8981\u70b9<\/div><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/knowledge\/white-paper\/fluorine.html\"><div class=\"lc-title\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66<\/div><div class=\"lc-desc\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u539f\u7406\u3001\u4f18\u52bf\u4e0e\u9002\u7528\u573a\u666f<\/div><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\"><div class=\"lc-title\">\u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6848\u4f8b<\/div><div class=\"lc-desc\">\u5168\u7ad9\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u7d22\u5f15\u4e0e\u5bfc\u822a<\/div><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\"><div class=\"lc-title\">\u7ad9\u70b9\u5730\u56fe \u00b7 \u5b98\u7f51\u5185\u5bb9\u8be6\u7ec6\u7d22\u5f15<\/div><div class=\"lc-desc\">\u9f99\u8109\u6696\u901a\u5b98\u7f51\u5185\u5bb9\u5b8c\u6574\u7d22\u5f15<\/div><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3553\"><div class=\"lc-title\">\u4ece\u4ef7\u683c\u7ea0\u7ed3\u5230\u7406\u6027\u9009\u62e9<\/div><div class=\"lc-desc\">\u4e3a\u4ec0\u4e48\u5218\u5973\u58eb\u4e3a120\u33a1\u4e09\u623f\u4e24\u5385\u9009\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247160<\/div><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=7031\"><div class=\"lc-title\">\u590d\u5730\u5d11\u7389\u9526\u57ce\u65e5\u7acb\u8212\u4eab140\u4e00\u62d6\u4e94\u6848\u4f8b<\/div><div class=\"lc-desc\">\u540c\u7c7b\u578b\u5e73\u5c42\u4e2d\u592e\u7a7a\u8c03\u5b8c\u5de5\u6848\u4f8b\u53c2\u8003<\/div><\/a>\n    <\/div>\n  <\/div>\n\n  <div class=\"store-cta-wrap\">\n    <div class=\"cta-header\">\n      <div class=\"cta-title\">\ud83d\udcde \u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 \u00b7 \u60a8\u5bb6\u4e5f\u60f3\u88c5\u7a7a\u8c03\uff1f<\/div>\n      <div class=\"cta-subtitle\">\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u91cf\u8eab\u5b9a\u5236\u7a7a\u8c03\u65b9\u6848 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5<\/div>\n    <\/div>\n\n    <div class=\"phone-cards\">\n      <a class=\"phone-card\" href=\"tel:02886131795\"><span class=\"pc-icon\">\ud83d\udcf1<\/span>\u5357\u5bcc\u68ee\u5e97\uff1a<span class=\"pc-num\">028-86131795<\/span><\/a>\n      <a class=\"phone-card\" href=\"tel:02865272586\"><span class=\"pc-icon\">\ud83d\udcf1<\/span>\u5317\u5bcc\u68ee\u5e97\uff1a<span class=\"pc-num\">028-65272586<\/span><\/a>\n\n      <a class=\"phone-card\" href=\"tel:13008113409\"><span class=\"pc-icon\">\ud83d\udc69<\/span>\u672c\u6848\u4f8b\u987e\u95ee\u4f59\u6653\u73b2\uff1a<span class=\"pc-num\">130-0811-3409<\/span><\/a>\n    <\/div>\n\n    <div class=\"local-serve\">\n      <div class=\"ls-item\">\ud83c\udd93 \u4e0a\u95e8\u5b9e\u5730\u52d8\u6d4b<\/div>\n      <div class=\"ls-item\">\ud83d\udcd0 \u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97<\/div>\n      <div class=\"ls-item\">\ud83d\udccb \u4e13\u5c5e\u6237\u578b\u65b9\u6848\u62a5\u4ef7<\/div>\n      <div class=\"ls-item\">\u2705 36\u9879\u65bd\u5de5\u8282\u70b9\u9a8c\u6536<\/div>\n    <\/div>\n\n    <div class=\"store-grid\">\n      <div class=\"store-item\">\n        <div class=\"store-badge\">\ud83c\udfea \u5357\u5bcc\u68ee\u5e97<\/div>\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <p class=\"store-addr\">\ud83d\udccd \u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/p>\n      <\/div>\n      <div class=\"store-item\">\n        <div class=\"store-badge\">\ud83c\udfea \u5317\u5bcc\u68ee\u5e97<\/div>\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" onerror=\"this.style.display='none'\">\n        <p class=\"store-addr\">\ud83d\udccd \u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/p>\n      <\/div>\n    <\/div>\n\n    <p style=\"margin-top:14px;font-size:0.82rem;color:var(--text-gray)\">\ud83d\uddfa\ufe0f <strong>\u6210\u90fd\u670d\u52a1\u8986\u76d6\u533a\u53bf\uff1a<\/strong>\u9ad8\u65b0\u3001\u6b66\u4faf\u3001\u6210\u534e\u3001\u9526\u6c5f\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u3001\u6e29\u6c5f\u3001\u65b0\u90fd\u7b49\u5168\u57df\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u65bd\u5de5\u3002<\/p>\n\n    <div class=\"action-row\">\n      <a class=\"btn-cta\" href=\"tel:02886131795\">\u514d\u8d39\u9884\u7ea6\u52d8\u6d4b \u2192<\/a>\n    <\/div>\n    <div class=\"disclaimer-note\">* \u5177\u4f53\u8d39\u7528\u56e0\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u800c\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/div>\n  <\/div>\n\n  <div class=\"privacy-statement\">\n    <div class=\"privacy-title\">\u8131\u654f\u58f0\u660e<\/div>\n    <div class=\"privacy-sub\">\u6570\u636e\u900f\u660e \u00b7 \u9690\u79c1\u4fdd\u62a4<\/div>\n    <ul class=\"privacy-list\">\n      <li>\u672c\u6848\u4f8b\u6280\u672f\u53c2\u6570\u4e3a\u771f\u5b9e\u6570\u636e\uff08\u6765\u6e90\u4e8e\u73b0\u573a\u52d8\u6d4b\u4e0e\u65b9\u6848\u8bbe\u8ba1\u8ba1\u7b97\u8868\uff09\u3002<\/li>\n      <li>\u4e1a\u4e3b\u9690\u79c1\u5df2\u8131\u654f\uff08\u771f\u5b9e\u59d3\u540d\u3001\u623f\u53f7\u3001\u5355\u5143\u697c\u5c42\u3001\u5177\u4f53\u9020\u4ef7\u672a\u516c\u5f00\uff09\u3002<\/li>\n      <li>\u6c9f\u901a\u8bb0\u5f55\u5df2\u8131\u654f\u5904\u7406\uff0c\u5173\u952e\u4e1a\u52a1\u4fe1\u606f\u4fdd\u7559\u5b8c\u6574\u6027\u3002<\/li>\n      <li>\u9020\u4ef7\u8bf4\u660e\uff1a\u5177\u4f53\u9020\u4ef7\u56e0\u65f6\u6548\u6027\u56e0\u7d20\u672a\u516c\u5f00\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\u3002<\/li>\n      <li>\u80fd\u8017\u6570\u636e\uff1a\u57fa\u4e8e\u6210\u90fd\u5730\u533a\u540c\u6237\u578b\u53c2\u8003\u503c\uff0c\u5b9e\u9645\u8d39\u7528\u56e0\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u6e29\u3001\u7535\u4ef7\u7b49\u56e0\u7d20\u6709\u5dee\u5f02\u3002<\/li>\n    <\/ul>\n  <\/div>\n\n  <div style=\"display:none\">\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 \u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ \u4e00\u62d6\u4e94 \u4e2d\u592e\u7a7a\u8c03 \u5e73\u5c42103.87\u33a1 APF5.80 \u8fde\u63a5\u7387119.4% \u603b\u5236\u51b7\u91cf18500W \u6210\u90fd\u6696\u901a \u9f99\u8109\u6696\u901a \u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546 \u8212\u4eab\u5185\u673a\u5b89\u88c5 \u7a7a\u8c03\u7cfb\u7edf\u8bbe\u8ba1<\/div>\n\n<\/main>\n\n<footer style=\"background:#1a1a2e;color:rgba(255,255,255,0.6);text-align:center;padding:28px 20px;font-size:13px;line-height:1.8\">\n  \u00a9 \u9f99\u8109\u6696\u901a 2004-2026 | \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 | \u8700ICP\u59072026015986\u53f7\n<\/footer>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"Article\",\n  \"headline\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\uff5c\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03 \u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b\",\n  \"description\":\"\u9f99\u8109\u6696\u901a\u843d\u5730\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u5e73\u5c42\u4f4f\u5b85\uff0c\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0c\u603b\u5236\u51b7\u91cf18500W\u3001\u8fde\u63a5\u7387119.4%\u3001APF 5.80\uff0c\u8986\u76d6\u5ba2\u9910\u5385+\u5165\u6237\u53a8\u623f43.4\u33a1+\u5bb6\u5ead\u5ba430.9\u33a1+\u4e3b\u536715.3\u33a1+\u6b21\u536714.27\u33a1\u5171103.87\u33a1\uff0c\u5168\u5957\u5b89\u88c5\u5b9e\u62cd\u3002\",\n  \"image\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-wjazsj.jpg\",\n  \"datePublished\":\"2026-08-07\",\n  \"dateModified\":\"2026-08-07\",\n  \"author\":{\"@type\":\"Person\",\"name\":\"\u4f59\u6653\u73b2\",\"jobTitle\":\"\u6696\u901a\u65b9\u6848\u8bbe\u8ba1\u5e08\"},\n  \"locationCreated\":{\"@type\":\"Place\",\"name\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\"},\n  \"brand\":{\"@type\":\"Brand\",\"name\":\"\u65e5\u7acb Hitachi\"},\n  \"publisher\":{\"@type\":\"Organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"url\":\"https:\/\/longmai-nt.com\/\"}\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\"@type\":\"Question\",\"name\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u5e73\u5c42\u88c5\u65e5\u7acb\u8212\u4eab160\u6574\u5957\u843d\u5730\u591a\u5c11\u94b1\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6574\u5957\u542b\u65e5\u7acb\u8212\u4eab160 RAS-160HRNAQ\u5916\u673a1\u53f0+5\u53f0\u5185\u673a+\u7ebf\u63a7\u56685\u4e2a+\u51b7\u5a92\u94dc\u7ba1\u53ca\u8f85\u6750\uff0c\u5177\u4f53\u9020\u4ef7\u9700\u73b0\u573a\u52d8\u6d4b\u540e\u51fa\u5177\u660e\u7ec6\u62a5\u4ef7\uff0c\u9f99\u8109\u6696\u901a\u627f\u8bfa\u96f6\u589e\u9879\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u5e73\u5c42103.87\u33a1\u7528\u8212\u4eab160\u4e00\u62d6\u4e94\u591f\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5b8c\u5168\u8db3\u591f\u4e14\u9884\u7559\u4f59\u91cf\u30025\u53f0\u5185\u673a\u603b\u5bb9\u91cf18500W\uff0c\u8212\u4eab160\u5916\u673a\u989d\u5b9a\u5236\u51b715500W\uff0c\u8fde\u63a5\u7387119.4%\u5728\u65e5\u7acb\u5b89\u5168\u7ecf\u6d4e\u8303\u56f4\u5185\u3002\u4e24\u5927\u516c\u533a+\u4e24\u5367\u5ba4\u5168\u5c4b\u540c\u5f00\u4e5f\u80fd\u6ee1\u8db3\u5236\u51b7\u9700\u6c42\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u65e5\u7acb\u8212\u4eab160\u7684APF 5.80\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u80fd\u7701\u591a\u5c11\u7535\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"APF 5.80\u662f\u65b0\u56fd\u6807\u4e00\u7ea7\u80fd\u6548\uff0c\u6570\u503c\u8d8a\u9ad8\u8d8a\u7701\u7535\u3002\u76f8\u6bd4\u8001\u4e09\u7ea7\u80fd\u6548\u673a\u578b\u6bcf\u5e74\u53ef\u8282\u7701\u7535\u8d39\u7ea630%\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u548c\u6302\u673a\u67dc\u673a\u6bd4\u54ea\u4e2a\u597d\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5e73\u5c42\u6237\u578b\u5f3a\u70c8\u5efa\u8bae\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff1a\u4ec51\u53f0\u5916\u673a\u3001\u5185\u85cf\u7f8e\u89c2\u3001\u5206\u5ba4\u6e29\u63a7\u3001\u8fd0\u884c\u5b89\u9759\u3001\u957f\u671f\u80fd\u8017\u66f4\u4f4e\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u9f99\u8109\u6696\u901a\u7684\u5b89\u88c5\u8d28\u4fdd\u591a\u4e45\uff1f\u51fa\u4e86\u95ee\u9898\u600e\u4e48\u529e\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5b89\u88c5\u90e8\u5206\u8d28\u4fdd\uff08\u975e\u4eba\u4e3a\u635f\u574f\u514d\u8d39\u7ef4\u4fee\uff09\uff0c\u65e5\u7acb\u6574\u673a\u539f\u5382\u4fdd\u4fee\u3002\u552e\u540e\u4e13\u7ebf\uff0c24\u5c0f\u65f6\u5185\u54cd\u5e94\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8fd9\u5957\u65b9\u6848\u540e\u671f\u52a0\u5730\u6696\u6216\u65b0\u98ce\u65b9\u4fbf\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u975e\u5e38\u65b9\u4fbf\u3002\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u3001\u5730\u6696\u7ba1\u9053\u5b8c\u5168\u72ec\u7acb\uff0c\u4e92\u4e0d\u5e72\u6270\u3002\u540e\u671f\u52a0\u88c5\u53ea\u9700\u65b0\u589e\u5bf9\u5e94\u7cfb\u7edf\u7ba1\u8def\uff0c\u539f\u6709\u7a7a\u8c03\u65e0\u9700\u6539\u52a8\u3002\"}}\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"BreadcrumbList\",\n  \"itemListElement\":[\n    {\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/longmai-nt.com\/\"},\n    {\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6848\u4f8b\u805a\u5408\u9875\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=2297\"},\n    {\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\u5b8c\u5de5\u6848\u4f8b\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=\u3010\u5f85\u8865\u9875\u9762ID\u3011\"}\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"LocalBusiness\",\n  \"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"url\":\"https:\/\/longmai-nt.com\/\",\n  \"telephone\":[\"028-86131795\",\"13008113409\"],\n  \"address\":[\n    {\"@type\":\"PostalAddress\",\"streetAddress\":\"\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348\",\"addressLocality\":\"\u6210\u90fd\u5e02\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"addressCountry\":\"CN\"},\n    {\"@type\":\"PostalAddress\",\"streetAddress\":\"\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7\",\"addressLocality\":\"\u6210\u90fd\u5e02\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"addressCountry\":\"CN\"}\n  ],\n  \"areaServed\":[\"\u9ad8\u65b0\",\"\u6b66\u4faf\",\"\u6210\u534e\",\"\u9526\u6c5f\",\"\u53cc\u6d41\",\"\u90eb\u90fd\",\"\u9f99\u6cc9\",\"\u6e29\u6c5f\",\"\u65b0\u90fd\"],\n  \"makesOffer\":[\n    {\"@type\":\"Offer\",\"name\":\"\u4e0a\u95e8\u5b9e\u5730\u52d8\u6d4b\"},\n    {\"@type\":\"Offer\",\"name\":\"\u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97\"},\n    {\"@type\":\"Offer\",\"name\":\"\u4e13\u5c5e\u6237\u578b\u65b9\u6848\u62a5\u4ef7\"},\n    {\"@type\":\"Offer\",\"name\":\"36\u9879\u65bd\u5de5\u8282\u70b9\u9a8c\u6536\"}\n  ],\n  \"brand\":{\"@type\":\"Brand\",\"name\":\"\u65e5\u7acb Hitachi\"}\n}\n<\/script>\n\n<script>\nconst tocBtns=document.querySelectorAll('.toc-btn');\nconst subtoc=document.getElementById('subtoc');\nconst panels=document.querySelectorAll('.subtoc-panel');\n\/\/ \u81ea\u52a8\u7ed9\u6bcf\u4e2a\u4e3b\u7ae0\u8282\u7684 h3.card-title \u751f\u6210\u951a\u70b9 id\uff08s{sec}-h{n}\uff09\ndocument.querySelectorAll('.step-section[id^=\"s\"]').forEach(sec=>{\n  let i=0;\n  sec.querySelectorAll('h3.card-title').forEach(h=>{ i++; h.id=sec.id+'-h'+i; });\n});\n\/\/ \u4e3b\u76ee\u5f55\u70b9\u51fb\uff1a\u6eda\u52a8\u5230\u5bf9\u5e94\u7ae0\u8282 + \u5c55\u5f00\/\u6536\u8d77\u5176\u5b50\u76ee\u5f55\ntocBtns.forEach(b=>{\n  b.addEventListener('click',()=>{\n    const t=b.dataset.target;\n    const el=document.getElementById(t);\n    if(el) el.scrollIntoView({behavior:'smooth',block:'start'});\n    const isOpen=b.classList.contains('open');\n    tocBtns.forEach(x=>x.classList.remove('open'));\n    panels.forEach(p=>p.classList.remove('open'));\n    if(!isOpen){\n      b.classList.add('open');\n      subtoc.classList.add('show');\n      const p=document.querySelector('.subtoc-panel[data-panel=\"'+t+'\"]');\n      if(p) p.classList.add('open');\n    } else {\n      subtoc.classList.remove('show');\n    }\n  });\n});\n\/\/ \u5b50\u76ee\u5f55\u70b9\u51fb\uff1a\u81ea\u52a8\u5c55\u5f00\u6298\u53e0\u677f\u5757 + \u5207\u6362\u5bf9\u5e94\u6807\u7b7e\u5361\u7247 + \u5b9a\u4f4d\npanels.forEach(panel=>{\n  panel.querySelectorAll('a').forEach(a=>{\n    a.addEventListener('click',()=>{\n      const hash=a.getAttribute('href');\n      if(!hash||!hash.startsWith('#'))return;\n      const target=document.querySelector(hash);\n      if(!target)return;\n      const section=target.closest('.step-section');\n      if(section){\n        const cb=section.querySelector('.fold-cb');\n        if(cb) cb.checked=true;\n        if(section.id==='s1'){\n          let t=null;\n          if(target.closest('[data-t=\"overview\"]')) t='overview';\n          else if(target.closest('[data-t=\"service\"]')) t='service';\n          else if(target.closest('.flip-back')) t='goal';\n          else if(target.closest('.info-goal-front')) t='info';\n          if(t){ if(typeof s1show==='function') s1show(t); }\n        } else {\n          const cards=section.querySelectorAll('.slider-card');\n          let idx=-1;\n          cards.forEach((c,i)=>{ if(c.contains(target)) idx=i; });\n          if(idx>=0){\n            const tabs=section.querySelectorAll('.section-tab');\n            tabs.forEach(t=>t.classList.remove('active'));\n            if(tabs[idx]) tabs[idx].classList.add('active');\n            cards.forEach(c=>c.classList.remove('active'));\n            cards[idx].classList.add('active');\n          }\n        }\n      }\n      setTimeout(()=>target.scrollIntoView({behavior:'smooth',block:'start'}),60);\n    });\n  });\n});\nconst sections=document.querySelectorAll('.step-section[id^=\"s\"]');\nconst obs=new IntersectionObserver((entries)=>{entries.forEach(e=>{if(e.isIntersecting){const id=e.target.id;tocBtns.forEach(btn=>btn.classList.toggle('active',btn.dataset.target===id));}});},{rootMargin:'-45% 0px -50% 0px'});\nsections.forEach(s=>obs.observe(s));\ndocument.querySelector('main').addEventListener('click',function(e){const tab=e.target.closest('.section-tab');if(!tab)return;const sec=tab.closest('.step-section');if(sec){ if(sec.id==='s1') return; }const sv=sec.querySelector('.slider-container');sv.querySelectorAll('.slider-card').forEach(c=>c.classList.remove('active'));sv.querySelectorAll('.slider-card')[tab.dataset.card].classList.add('active');tab.closest('.section-tabs').querySelectorAll('.section-tab').forEach(t=>t.classList.remove('active'));tab.classList.add('active');});\n\nfunction togglePanel(btn){\n  const panel=btn.nextElementSibling;\n  const open=panel.classList.contains('show');\n  panel.classList.toggle('show');btn.classList.toggle('open',!open);\n}\nfunction toggleAdv(btn){\n  const full=btn.nextElementSibling;\n  full.classList.toggle('show');\n  btn.textContent=full.classList.contains('show')?'\u6536\u8d77\u8be6\u60c5':'\u5c55\u5f00\u8be6\u60c5';\n}\nfunction toggleFaq(q){\n  const a=q.nextElementSibling;\n  a.classList.toggle('show');q.classList.toggle('open');\n}\ndocument.addEventListener('click',function(e){\n  const step=e.target.closest('.timeline-step');\n  if(!step)return;\n  const ti=step.dataset.step;\n  document.querySelectorAll('.timeline-step').forEach(s=>s.classList.remove('active'));\n  step.classList.add('active');\n  document.querySelectorAll('.timeline-detail').forEach(d=>d.classList.remove('show'));\n  const detail=document.getElementById('timelineDetail'+ti);\n  if(detail) detail.classList.add('show');\n});\n\/\/ \u8bbe\u8ba1\u56fe\u7eb8\u7ffb\u8f6c\u5361\u7247\nconst designFlip=document.getElementById('designFlipCard');\nif(designFlip){\n  designFlip.addEventListener('click',function(){this.classList.toggle('flipped');});\n}\n\/\/ S1 \u5ba2\u6237\u4fe1\u606f\u5361\u2194\u8212\u9002\u76ee\u6807 \u7ffb\u8f6c\u5361\u724c\uff1a\u70b9\u51fb\u4efb\u610f\u4f4d\u7f6e\u7ffb\u8f6c + \u4e0e tab \u8054\u52a8\nconst infoGoalFlip=document.getElementById('infoGoalFlip');\nfunction s1show(t){\n  if(!infoGoalFlip)return;\n  const sec=document.getElementById('s1');\n  if(!sec)return;\n  sec.querySelectorAll('.section-tab').forEach(tb=>tb.classList.toggle('active', tb.dataset.t===t));\n  const isFlip=(t==='info'||t==='goal');\n  infoGoalFlip.style.display=isFlip?'':'none';\n  infoGoalFlip.classList.toggle('flipped', t==='goal');\n  sec.querySelectorAll('.slider-card').forEach(c=>{\n    const on=(c.dataset.t===t);\n    c.style.display=on?'block':'none';\n    c.classList.toggle('active', on);\n  });\n}\nif(infoGoalFlip){\n  \/\/ \u70b9\u51fb\u5361\u7247\u4efb\u610f\u4f4d\u7f6e\u5373\u53ef\u7ffb\u8f6c\uff08\u542b\u5403\u8c46\u4eba\u533a\uff09\uff0c\u5e76\u540c\u6b65 tab \u9ad8\u4eae\n  infoGoalFlip.addEventListener('click',function(){\n    if(infoGoalFlip.style.display==='none')return;\n    infoGoalFlip.classList.toggle('flipped');\n    const flipped=infoGoalFlip.classList.contains('flipped');\n    const sec=document.getElementById('s1');\n    if(sec) sec.querySelectorAll('.section-tab').forEach(tb=>tb.classList.toggle('active', tb.dataset.t===(flipped?'goal':'info')));\n  });\n}\n\/\/ S1 tab \u6309\u94ae\uff1a\u505c\u6b62\u5192\u6ce1\uff0c\u907f\u514d\u89e6\u53d1\u901a\u7528 tab \u5904\u7406\ndocument.querySelectorAll('#s1 .section-tab').forEach(tab=>{\n  tab.addEventListener('click',function(e){ e.stopPropagation(); if(typeof s1show==='function') s1show(tab.dataset.t); });\n});\ns1show('info');\n\/\/ \u8212\u9002\u76ee\u6807\u5403\u8c46\u4eba\u53ef\u89c6\u5316\uff08\u81ea\u52a8\u5de1\u822a\uff09\n(function(){\n  const track=document.getElementById('pacmanTrack');\n  if(!track)return;\n  const pacman=document.getElementById('pacman');\n  const dots=track.querySelectorAll('.pac-dot');\n  const detail=document.getElementById('pacmanDetail');\n  if(!dots.length)return;\n  const ICONS={\n    '\u590f\u5b63\u5236\u51b7':'<svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 2v20M4 7l16 10M20 7L4 17M2 12h20\"\/><\/svg>',\n    '\u8fd0\u884c\u5b89\u9759':'<svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M11 5 6 9H2v6h4l5 4z\"\/><path d=\"m23 9-6 6M17 9l6 6\"\/><\/svg>',\n    '\u7a33\u5b9a\u7701\u5fc3':'<svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M12 2 4 5v6c0 5 3.5 8.5 8 11 4.5-2.5 8-6 8-11V5z\"\/><\/svg>',\n    '\u8282\u80fd\u7701\u7535':'<svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M13 2 4 14h7l-1 8 9-12h-7z\"\/><\/svg>',\n    '\u64cd\u4f5c\u7b80\u5355':'<svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><rect x=\"3\" y=\"8\" width=\"18\" height=\"8\" rx=\"4\"\/><circle cx=\"17\" cy=\"12\" r=\"3\" fill=\"currentColor\" stroke=\"none\"\/><\/svg>'\n  };\n  dots.forEach(function(d){\n    var lbl=d.querySelector('.dot-label');\n    if(lbl){ if(ICONS[d.dataset.title]) lbl.insertAdjacentHTML('afterbegin','<span class=\"goal-ico\">'+ICONS[d.dataset.title]+'<\/span>'); }\n  });\n  var mp0=detail.querySelector('.mini-pac');\n  if(mp0){ if(ICONS[dots[0].dataset.title]) mp0.innerHTML=ICONS[dots[0].dataset.title]; }\n  let idx=0, timer=null;\n  function setDetail(i){\n    const data=dots[i].dataset;\n    detail.querySelector('.d-title').textContent=data.title;\n    detail.querySelector('.stars').textContent=data.stars;\n    detail.querySelector('.detail-body').textContent=data.text;\n    const mp=detail.querySelector('.mini-pac');\n    if(mp){ if(ICONS[data.title]) mp.innerHTML=ICONS[data.title]; }\n  }\n  let pacTimer=null;\n  function moveTo(i,dir){\n    const dot=dots[i];\n    const center=dot.offsetLeft + dot.offsetWidth\/2 - pacman.offsetWidth\/2;\n    pacman.style.left=center+'px';\n    pacman.style.transform=dir<0?'scaleX(-1)':'scaleX(1)';\n  }\n  function approachPos(i,dir){\n    const dot=dots[i];\n    const center=dot.offsetLeft + dot.offsetWidth\/2 - pacman.offsetWidth\/2;\n    return center - dir*22;\n  }\n  function markEaten(i){\n    dots.forEach(d=>d.classList.remove('active'));\n    dots[i].classList.add('active');\n  }\n  function eat(i,dir){\n    idx=i;\n    clearTimeout(pacTimer);\n    setDetail(i);\n    if(i>0){\n      pacman.style.transform=dir<0?'scaleX(-1)':'scaleX(1)';\n      pacman.style.left=approachPos(i,dir)+'px';\n      pacTimer=setTimeout(function(){\n        moveTo(i,dir);\n        markEaten(i);\n      },900);\n    }else{\n      moveTo(i,dir);\n      markEaten(i);\n    }\n  }\n  function reset(){\n    dots.forEach(d=>d.classList.remove('active'));\n    pacman.style.transition='none';\n    moveTo(0,1);\n    void pacman.offsetWidth;\n    pacman.style.transition='';\n  }\n  function step(){\n    idx++;\n    if(idx>=dots.length){\n      timer=setTimeout(function(){ reset(); idx=0; eat(0,1); timer=setTimeout(step,2200); },2500);\n      return;\n    }\n    eat(idx,1);\n    timer=setTimeout(step,3800);\n  }\n  dots.forEach((d,i)=>d.addEventListener('click',function(){\n    clearTimeout(timer); clearTimeout(pacTimer);\n    const dir=i<idx?-1:1;\n    eat(i,dir);\n    timer=setTimeout(step,4200);\n  }));\n  setTimeout(function(){ eat(0,1); timer=setTimeout(step,3800); },300);\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u771f\u5b9e\u6848\u4f8b \u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56 [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":2297,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-10055","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u5b8c\u5de5\u5b9e\u62cd<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 103.87\u33a1\u5e73\u5c42\u5b8c\u5de5\uff0c\u9009\u7528\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0cAPF5.80 \u9ad8\u80fd\u6548\u4e00\u7ea7\u80fd\u6548\uff0c43.4\u33a1\u5ba2\u9910\u5385\u642d\u914d 50+22 \u53cc\u5185\u673a\uff0c\u5168\u5c4b\u603b\u5236\u51b7 18500W\uff0c\u8fde\u63a5\u7387 119.4%\uff0c\u4e25\u683c\u6309\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c\u76f4\u8425\u7cbe\u5de5\u65bd\u5de5\uff0c\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u6d4b\u7b97\u51b7\u70ed\u8d1f\u8377\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=10055\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u5b8c\u5de5\u5b9e\u62cd\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 103.87\u33a1\u5e73\u5c42\u5b8c\u5de5\uff0c\u9009\u7528\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0cAPF5.80 \u9ad8\u80fd\u6548\u4e00\u7ea7\u80fd\u6548\uff0c43.4\u33a1\u5ba2\u9910\u5385\u642d\u914d 50+22 \u53cc\u5185\u673a\uff0c\u5168\u5c4b\u603b\u5236\u51b7 18500W\uff0c\u8fde\u63a5\u7387 119.4%\uff0c\u4e25\u683c\u6309\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c\u76f4\u8425\u7cbe\u5de5\u65bd\u5de5\uff0c\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u6d4b\u7b97\u51b7\u70ed\u8d1f\u8377\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=10055\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-11T13:56:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"12 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055\",\"name\":\"\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u5b8c\u5de5\u5b9e\u62cd\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/lhstyya-cls-njazsj-01.jpg\",\"datePublished\":\"2026-08-08T04:37:04+00:00\",\"dateModified\":\"2026-11-11T13:56:44+00:00\",\"description\":\"\u6210\u90fd\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 103.87\u33a1\u5e73\u5c42\u5b8c\u5de5\uff0c\u9009\u7528\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0cAPF5.80 \u9ad8\u80fd\u6548\u4e00\u7ea7\u80fd\u6548\uff0c43.4\u33a1\u5ba2\u9910\u5385\u642d\u914d 50+22 \u53cc\u5185\u673a\uff0c\u5168\u5c4b\u603b\u5236\u51b7 18500W\uff0c\u8fde\u63a5\u7387 119.4%\uff0c\u4e25\u683c\u6309\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c\u76f4\u8425\u7cbe\u5de5\u65bd\u5de5\uff0c\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u6d4b\u7b97\u51b7\u70ed\u8d1f\u8377\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/lhstyya-cls-njazsj-01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/lhstyya-cls-njazsj-01.jpg\",\"width\":1080,\"height\":1440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10055#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2297\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8521\u8001\u5e08\u65e5\u7acb\u8212\u4eab160\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u5b8c\u5de5\u5b9e\u62cd","description":"\u6210\u90fd\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 103.87\u33a1\u5e73\u5c42\u5b8c\u5de5\uff0c\u9009\u7528\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0cAPF5.80 \u9ad8\u80fd\u6548\u4e00\u7ea7\u80fd\u6548\uff0c43.4\u33a1\u5ba2\u9910\u5385\u642d\u914d 50+22 \u53cc\u5185\u673a\uff0c\u5168\u5c4b\u603b\u5236\u51b7 18500W\uff0c\u8fde\u63a5\u7387 119.4%\uff0c\u4e25\u683c\u6309\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c\u76f4\u8425\u7cbe\u5de5\u65bd\u5de5\uff0c\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u6d4b\u7b97\u51b7\u70ed\u8d1f\u8377\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=10055","og_locale":"zh_CN","og_type":"article","og_title":"\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u5b8c\u5de5\u5b9e\u62cd","og_description":"\u6210\u90fd\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 103.87\u33a1\u5e73\u5c42\u5b8c\u5de5\uff0c\u9009\u7528\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0cAPF5.80 \u9ad8\u80fd\u6548\u4e00\u7ea7\u80fd\u6548\uff0c43.4\u33a1\u5ba2\u9910\u5385\u642d\u914d 50+22 \u53cc\u5185\u673a\uff0c\u5168\u5c4b\u603b\u5236\u51b7 18500W\uff0c\u8fde\u63a5\u7387 119.4%\uff0c\u4e25\u683c\u6309\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c\u76f4\u8425\u7cbe\u5de5\u65bd\u5de5\uff0c\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u6d4b\u7b97\u51b7\u70ed\u8d1f\u8377\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=10055","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-11T13:56:44+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"12 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=10055","url":"https:\/\/longmai-nt.com\/?page_id=10055","name":"\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u5b8c\u5de5\u5b9e\u62cd","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=10055#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=10055#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-01.jpg","datePublished":"2026-08-08T04:37:04+00:00","dateModified":"2026-11-11T13:56:44+00:00","description":"\u6210\u90fd\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8 103.87\u33a1\u5e73\u5c42\u5b8c\u5de5\uff0c\u9009\u7528\u65e5\u7acb\u8212\u4eab 160 \u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03\uff0cAPF5.80 \u9ad8\u80fd\u6548\u4e00\u7ea7\u80fd\u6548\uff0c43.4\u33a1\u5ba2\u9910\u5385\u642d\u914d 50+22 \u53cc\u5185\u673a\uff0c\u5168\u5c4b\u603b\u5236\u51b7 18500W\uff0c\u8fde\u63a5\u7387 119.4%\uff0c\u4e25\u683c\u6309\u56fd\u6807\u9010\u623f\u95f4\u6d4b\u7b97\u51b7\u8d1f\u8377\uff0c\u76f4\u8425\u7cbe\u5de5\u65bd\u5de5\uff0c\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u6d4b\u7b97\u51b7\u70ed\u8d1f\u8377\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=10055#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=10055"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=10055#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhstyya-cls-njazsj-01.jpg","width":1080,"height":1440},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=10055#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3","item":"https:\/\/longmai-nt.com\/?page_id=2297"},{"@type":"ListItem","position":3,"name":"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u9e93\u6e56\u751f\u6001\u57ce\u6c84\u5cb8\u8521\u8001\u5e08\u65e5\u7acb\u8212\u4eab160\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10055"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10055\/revisions"}],"predecessor-version":[{"id":15955,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10055\/revisions\/15955"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2297"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}