{"id":10122,"date":"2026-08-08T18:50:26","date_gmt":"2026-08-08T10:50:26","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=10122"},"modified":"2026-11-14T19:29:28","modified_gmt":"2026-11-14T11:29:28","slug":"%e9%be%99%e6%b9%96%e5%85%89%e5%b9%b4-%e6%9d%8e%e5%a5%b3%e5%a3%ab%e5%88%ab%e5%a2%85%e6%9a%96%e9%80%9a%e6%96%b9%e6%a1%88%e5%85%a8%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=10122","title":{"rendered":"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66"},"content":{"rendered":"\n\n<!-- ===== \u7ed3\u6784\u5316\u6570\u636e\uff1aArticle \/ FAQPage \/ Product ===== -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66\",\n      \"description\": \"\u6210\u90fd\u9f99\u6e56\u5149\u5e74\uff08\u5ba2\u6237\u6863\u6848\u53f7KH-2026-0395\uff09\u674e\u5973\u58eb\u56db\u5c42\u522b\u5885\uff081F-4F\uff0c\u91c7\u6696\u9762\u79ef\u7ea6380\u33a1\u3001\u5730\u6696\u94fa\u8bbe370\u33a1\uff0c\u5e38\u4f4f4-5\u4eba\uff0c\u8001\u5ba2\u6237\u63a8\u8350\uff09\u5168\u5c4b\u6696\u901a\u65b9\u6848\uff1a\u4e00\u4e8c\u697c\u5e38\u5f00\u533a\u57df\u91c7\u7528\u65e5\u7acb\u5c0a\u777f\u5168\u6548280+\u6c34\u6a21\u5757280\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff08\u62d69\u53f0\u5185\u673a\uff09\uff1b\u4e09\u56db\u697c\u5b50\u5973\u56de\u5bb6\u533a\u57df\u91c7\u7528\u5c0a\u777f\u5168\u6548160+\u6c34\u6a21\u5757160\uff08\u62d65\u53f0\u5185\u673a\uff09\u3002\u5ba2\u6237\u4e60\u60ef\u56db\u5b63\u5f00\u7a97\u901a\u98ce\uff0c\u6545\u4e0d\u914d\u7f6e\u65b0\u98ce\u7cfb\u7edf\u548c\u96c6\u63a7\u5c4f\u3002\u5ef6\u5c55\u4e3a\u4e09\u8054\u4f9b\u7cfb\u7edf\uff1a\u589e\u52a0\u7f8e\u56fd\u745e\u7f8e150\u5347\u6362\u70ed\u6c34\u7bb1+\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5+\u7f8e\u56fd\u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\uff0c\u5b9e\u73b0\u5236\u51b7\u00b7\u91c7\u6696\u00b7\u751f\u6d3b\u70ed\u6c34\u4e09\u8054\u4f9b\u3002\u590f\u5b63\u7a7a\u8c03\u5b63\u70ed\u6cf5\u4f9b\u70ed\u6c34\uff08\u7701\u6c14\uff09\uff0c\u91c7\u6696\u5b63\u71c3\u6c14\u70ed\u6c34\u5668\u8054\u52a8\u6362\u70ed\u6c34\u7bb1\u4f9b\u751f\u6d3b\u70ed\u6c34\uff0c\u6ee1\u8db3\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u4f7f\u7528\u3002\u542b370\u33a1\u5730\u6696\u3001\u900f\u660e\u62a5\u4ef7\u3001\u6750\u6599\u8f85\u6750\u6e05\u5355\u3001\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u3001\u552e\u540e10\u5e74\u80fd\u6e90\u4fdd\u969c\u3002\",\n      \"author\": { \"@type\": \"Person\", \"name\": \"\u4f59\u6653\u73b2\", \"jobTitle\": \"\u6696\u901a\u8bbe\u8ba1\u5e08\", \"telephone\": \"130-0811-3409\" },\n      \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"\u9f99\u8109\u6696\u901a\",\n        \"logo\": { \"@type\": \"ImageObject\", \"url\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" }\n      },\n      \"datePublished\": \"2026-08-08\",\n      \"dateModified\": \"2026-08-13\",\n      \"mainEntityOfPage\": { \"@type\": \"WebPage\", \"@id\": \"https:\/\/longmai-nt.com\/?page_id=7224\" },\n      \"identifier\": { \"@type\": \"PropertyValue\", \"name\": \"\u5ba2\u6237\u6863\u6848\u53f7\", \"value\": \"KH-2026-0395\" },\n      \"about\": { \"@type\": \"Thing\", \"name\": \"\u522b\u5885\u6696\u901a\u4e09\u8054\u4f9b\u7cfb\u7edf\u8bbe\u8ba1\u65b9\u6848\" }\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u539f\u522b\u5885\u5176\u4ed6\u54c1\u724c\u7a7a\u8c03\u6709\u54ea\u4e9b\u75db\u70b9\uff0c\u4e3a\u4ec0\u4e48\u8981\u6362\u6210\u5c0a\u777f\u5168\u6548\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u674e\u5973\u58eb\u539f\u522b\u5885\u5b89\u88c5\u7684\u662f\u5176\u4ed6\u54c1\u724c\u7a7a\u8c03\uff0c\u4f7f\u7528\u4e2d\u5b58\u5728\u4e09\u5927\u75db\u70b9\uff1a\u2460\u566a\u97f3\u504f\u5927\uff0c\u591c\u95f4\u5f71\u54cd\u7761\u7720\uff1b\u2461\u98ce\u5927\u76f4\u5439\u3001\u8d8a\u5439\u8d8a\u51b7\uff0c\u4f53\u611f\u5e72\u51b7\u4e0d\u5747\uff1b\u2462\u80fd\u8017\u9ad8\uff0c\u51ac\u5b63\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u7ea615,000\u5143\/\u5e74\u3002\u5c0a\u777f\u5168\u6548\u4ee5\u6700\u4f4e17dB\u9759\u97f3\u5185\u673a\uff08\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\u226430dB\uff09\u3001\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u67d4\u548c\u9001\u98ce\u3001\u5929\u6c1f\u5730\u6c34\u7a7a\u6c14\u80fdCOP\u22653.0 + \u53cc\u7cfb\u7edf\u5206\u533a\u542f\u505c\uff0c\u9488\u5bf9\u6027\u89e3\u51b3\u8fd9\u4e09\u5927\u75db\u70b9\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5185\u673a\u566a\u97f3\u80fd\u505a\u5230\u591a\u5c11\uff1f\u5367\u5ba4\u591c\u95f4\u662f\u5426\u5b89\u9759\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5c0a\u777f\u5168\u6548\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f317dB\uff0c\u5367\u5ba4\u91c7\u7528\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\u53ef\u5c06\u8fd0\u884c\u566a\u97f3\u63a7\u5236\u5728\u226430dB\uff0c\u8fdc\u4f18\u4e8e\u539f\u7a7a\u8c03\uff0c\u591a\u4ee3\u540c\u5802\u591c\u95f4\u4f11\u606f\u4e0d\u88ab\u6253\u6270\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u51fa\u98ce\u4f1a\u4e0d\u4f1a\u76f4\u5439\u8fc7\u51b7\uff1f\u6e29\u5ea6\u662f\u5426\u5747\u5300\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u673a\u67d4\u548c\u9001\u98ce\uff0c\u914d\u5408\u5206\u533a\u63a7\u6e29\uff0c\u907f\u514d\u51b7\u98ce\u76f4\u5439\u4e0e\u8fc7\u51b7\u4e0d\u9002\uff1b\u5168\u5c4b\u6e29\u5ea6\u5747\u5300\u65e0\u6b7b\u89d2\uff0c\u89e3\u51b3\u539f\u7a7a\u8c03'\u8d8a\u5439\u8d8a\u51b7'\u7684\u75db\u70b9\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u4ec0\u4e48\u662f\u4e09\u8054\u4f9b\u7cfb\u7edf\uff1f\u672c\u6848\u5982\u4f55\u5b9e\u73b0\u5236\u51b7\u00b7\u91c7\u6696\u00b7\u751f\u6d3b\u70ed\u6c34\u4e09\u8054\u4f9b\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e09\u8054\u4f9b\u7cfb\u7edf\u6307\u4e00\u5957\u70ed\u6cf5\u7cfb\u7edf\u540c\u65f6\u63d0\u4f9b\u5236\u51b7\u3001\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u4e09\u79cd\u529f\u80fd\u3002\u672c\u6848\u4ee5\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u4e3a\u57fa\u7840\uff08\u5236\u51b7+\u5730\u6696\u91c7\u6696\uff09\uff0c\u5ef6\u5c55\u589e\u52a0\u7f8e\u56fd\u745e\u7f8e150\u5347\u6362\u70ed\u6c34\u7bb1+\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5+\u7f8e\u56fd\u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\uff0c\u5f62\u6210\u4e09\u8054\u4f9b\u3002\u590f\u5b63\u7a7a\u8c03\u8fd0\u884c\u65f6\u70ed\u6cf5\u53ef\u540c\u65f6\u52a0\u70ed\u6362\u70ed\u6c34\u7bb1\u4f9b\u751f\u6d3b\u70ed\u6c34\uff08\u5229\u7528\u7a7a\u6c14\u80fdCOP\u22653.0\uff0c\u7701\u6c14\u8d39\uff09\uff1b\u975e\u91c7\u6696\u8fc7\u6e21\u5b63\u70ed\u6cf5\u4e5f\u53ef\u72ec\u7acb\u4f9b\u70ed\u6c34\uff1b\u51ac\u5b63\u91c7\u6696\u5b63\u70ed\u6cf5\u4f18\u5148\u9a71\u52a8\u5730\u6696\uff0c\u753120L\u71c3\u6c14\u70ed\u6c34\u5668\u8054\u52a8150L\u6362\u70ed\u6c34\u7bb1\u4fdd\u969c\u751f\u6d3b\u70ed\u6c34\uff0c\u6ee1\u8db3\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u4f7f\u7528\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u4e3a\u4ec0\u4e48\u4e0d\u914d\u7f6e\u65b0\u98ce\u7cfb\u7edf\u548c\u96c6\u63a7\u5c4f\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u674e\u5973\u58eb\u4e60\u60ef\u4e00\u5e74\u56db\u5b63\u5f00\u7a97\u901a\u98ce\uff0c\u81ea\u7136\u901a\u98ce\u5df2\u80fd\u6ee1\u8db3\u5ba4\u5185\u6362\u6c14\u9700\u6c42\uff0c\u65b0\u98ce\u7cfb\u7edf\u7684\u4ef7\u503c\u4e0d\u5927\uff0c\u6545\u53d6\u6d88\u4ee5\u8282\u7701\u6295\u8d44\u3002\u96c6\u63a7\u5c4f\u4e3a\u65e5\u7acb\u5168\u5c4b\u5168\u611f2.0\u4e94\u6052\u7edf\u4e00\u96c6\u63a7\u7ec8\u7aef\uff0c\u672c\u6848\u53d6\u6d88\u65b0\u98ce\u540e\u4e0d\u518d\u9700\u8981\u4e94\u6052\u7edf\u4e00\u96c6\u63a7\uff0c\u5404\u5185\u673a\u914d\u72ec\u7acb\u7ebf\u63a7\u5668\u5373\u53ef\u64cd\u63a7\uff0c\u66f4\u7b80\u5355\u76f4\u63a5\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\u5982\u4f55\u8282\u7701\u71c3\u6c14\u8d39\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u674e\u5973\u58eb\u5c0f\u533a\u5929\u7136\u6c14\u6536\u8d39\u8f83\u8d35\uff084\u5143\u591a\/\u7acb\u65b9\uff09\u3002\u4e09\u8054\u4f9b\u7cfb\u7edf\u7684\u8282\u80fd\u903b\u8f91\uff1a\u2460\u590f\u5b63\u7a7a\u8c03\u5b63\u2014\u2014\u70ed\u6cf5\u5236\u51b7\u540c\u65f6\u52a0\u70ed\u6362\u70ed\u6c34\u7bb1\uff0c\u7a7a\u6c14\u80fdCOP\u22653.0\uff0c\u70ed\u6c34\u51e0\u4e4e\u96f6\u6c14\u8d39\uff1b\u2461\u8fc7\u6e21\u5b63\u2014\u2014\u70ed\u6cf5\u72ec\u7acb\u4f9b\u70ed\u6c34\uff0c\u540c\u6837\u5229\u7528\u7a7a\u6c14\u80fd\u9ad8\u80fd\u6548\u6bd4\uff0c\u71c3\u6c14\u70ed\u6c34\u5668\u4e0d\u5f00\u673a\uff1b\u2462\u4ec5\u51ac\u5b63\u91c7\u6696\u5b63\u2014\u2014\u70ed\u6cf5\u5168\u529b\u9a71\u52a8\u5730\u6696\u65f6\uff0c\u71c3\u6c14\u70ed\u6c34\u5668\u8054\u52a8\u6362\u70ed\u6c34\u7bb1\u4f9b\u751f\u6d3b\u70ed\u6c34\u3002\u5168\u5e74\u5927\u90e8\u5206\u65f6\u95f4\u7528\u7a7a\u6c14\u80fd\u4f9b\u70ed\u6c34\uff0c\u5927\u5e45\u964d\u4f4e\u71c3\u6c14\u8d39\u7528\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"150\u5347\u6362\u70ed\u6c34\u7bb1+20\u5347\u70ed\u6c34\u5668\u80fd\u6ee1\u8db3\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u4f7f\u7528\u5417\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5b8c\u5168\u53ef\u4ee5\u3002\u7f8e\u56fd\u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\u4e3a20L\/min\u5927\u5bb9\u91cf\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u6301\u7eed\u51fa\u6c34\u80fd\u529b20\u5347\/\u5206\u949f\uff1b\u914d\u5408150\u5347\u6362\u70ed\u6c34\u7bb1\u4f5c\u4e3a\u7f13\u51b2\u50a8\u80fd\uff0c\u51ac\u5b63\u91c7\u6696\u5b63\u53cc\u536b\u540c\u65f6\u6dcb\u6d74\u65f6\uff0c\u71c3\u6c14\u70ed\u6c34\u5668\u6301\u7eed\u52a0\u70ed+\u6c34\u7bb1\u50a8\u80fd\u534f\u540c\u4f9b\u6c34\uff0c\u4e0d\u4f1a\u51fa\u73b0\u5ffd\u51b7\u5ffd\u70ed\u6216\u6c34\u91cf\u4e0d\u8db3\u3002\u590f\u5b63\u548c\u8fc7\u6e21\u5b63\u7531\u70ed\u6cf5\u52a0\u70ed150L\u6c34\u7bb1\uff0c\u50a8\u6c34\u91cf\u5145\u8db3\uff0c\u53cc\u536b\u540c\u65f6\u4f7f\u7528\u6beb\u65e0\u538b\u529b\u3002\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5\u786e\u4fdd\u7ba1\u8def\u4e2d\u70ed\u6c34\u5373\u5f00\u5373\u6765\uff0c\u65e0\u9700\u653e\u51b7\u6c34\u7b49\u5f85\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u8fd9\u5957\u7cfb\u7edf\u5168\u5e74\u80fd\u8017\u5bf9\u6bd4\u73b0\u72b615,000\u5143\/\u5e74\u91c7\u6696\u80fd\u7701\u591a\u5c11\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u539f\u7a7a\u8c03\u51ac\u5b63\u91c7\u6696\u5b63\u7ea615,000\u5143\/\u5e74\u3002\u672c\u6848\u5929\u6c1f\u5730\u6c34\u7531\u7a7a\u6c14\u80fd\u6c34\u6a21\u5757\u9a71\u52a8\u5730\u6696COP\u22653.0\uff0c\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u770130%\u4ee5\u4e0a\uff1b\u53e0\u52a0280\uff08\u5e38\u5f00\uff09+160\uff08\u5076\u7528\uff09\u53cc\u7cfb\u7edf\u5206\u533a\u542f\u505c\uff0c\u5b50\u5973\u4e0d\u5728\u5bb6\u65f6\u4e09\u56db\u697c\u5b8c\u5168\u5173\u673a\uff0c\u5168\u5e74\u8fd0\u884c\u8d39\u8f83\u73b0\u72b6\u57fa\u51c6\u663e\u8457\u4e0b\u964d\u3002\u53c2\u8003\u540c\u7c7b\u578b\u5c0a\u777f\u5927\u5b85\uff08\u548c\u8d35\u5357\u5c71\u4e0a450\u33a1\u91c7\u6696\u6708\u71c3\u6c14\u8d39\u4e0d\u8db32000\u5143\uff09\uff0c\u957f\u671f\u8282\u80fd\u53ef\u89c2\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u56db\u5c42\u522b\u5885\u4e3a\u4ec0\u4e48\u5206\u4e24\u5957\u5c0a\u777f\u5168\u6548\u7cfb\u7edf\uff08280+160\uff09\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e00\u4e8c\u697c\u662f\u7236\u6bcd\/\u8001\u4eba\u5e38\u5f00\u533a\u57df\uff0c\u5168\u5929\u9ad8\u9891\u4f7f\u7528\uff0c\u914d\u5c0a\u777f\u5168\u6548280\uff0828kW\uff09\u4e00\u62d6\u4e5d\u4fdd\u8bc1\u5168\u5f00\u4e0d\u964d\u9891\uff1b\u4e09\u56db\u697c\u662f\u5b50\u5973\u5468\u672b\u56de\u5bb6\u624d\u7528\uff0c\u4f7f\u7528\u9891\u7387\u4f4e\uff0c\u914d\u5c0a\u777f\u5168\u6548160\uff0816kW\uff09\u4e00\u62d6\u4e94\u65e2\u6ee1\u8db3\u9700\u6c42\u53c8\u663e\u8457\u964d\u4f4e\u521d\u6295\u8d44\u3002\u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\u3001\u72ec\u7acb\u8ba1\u8d39\uff0c\u5e38\u5f00\u533a\u4e0e\u5076\u7528\u533a\u5206\u533a\u63a7\u5236\uff0c\u957f\u671f\u66f4\u8282\u80fd\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u4e09\u7ba1\u5236\u548c\u4e8c\u7ba1\u5236\u5185\u673a\u600e\u4e48\u9009\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5ba2\u9910\u5385\u3001\u5367\u5ba4\u3001\u4e66\u623f\u7b49\u9700\u6052\u6e29\u6052\u6e7f\u6052\u51c0\u7684\u4e3b\u7a7a\u95f4\u7528\u4e09\u7ba1\u5236\u5185\u673a\uff08\u6e29\u6e7f\u53cc\u63a7+PE\u51c0\u5316+\u81ea\u6e05\u6d01\uff09\uff1b\u50a8\u85cf\u5ba4\u3001\u591a\u529f\u80fd\u5ba4\u7b49\u4f4e\u9891\u4f7f\u7528\u7a7a\u95f4\u7528\u4e8c\u7ba1\u5236\u51c0\u5316\u5185\u673a\u5373\u53ef\uff0c\u6027\u4ef7\u6bd4\u66f4\u9ad8\u3002\u672c\u684814\u53f0\u5185\u673a\u6309\u7a7a\u95f4\u5c5e\u6027\u5206\u7ea7\u914d\u7f6e\uff0c\u628a\u94b1\u82b1\u5728\u5200\u5203\u4e0a\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u50a8\u85cf\u5ba4\u4e3a\u4ec0\u4e48\u7528\u4e8c\u7ba1\u5236\u4e14\u4e0d\u505a\u5730\u6696\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u50a8\u85cf\u5ba4\u4ee5\u50a8\u7269\u4e3a\u4e3b\uff0c\u65e0\u957f\u65f6\u95f4\u505c\u7559\u9700\u6c42\uff0c\u91c7\u7528\u4e8c\u7ba1\u5236\u51c0\u5316\u5185\u673a\u6ee1\u8db3\u57fa\u672c\u51b7\u6696\u5373\u53ef\uff0c\u4e0d\u914d\u7f6e\u5730\u6696\uff08\u65e0\u5730\u9762\u6563\u70ed\u9700\u6c42\uff09\uff0c\u65e2\u8282\u7701\u521d\u6295\u8d44\u4e5f\u907f\u514d\u95f2\u7f6e\u80fd\u8017\u3002\u5730\u6696370\u33a1\u8986\u76d6\u5176\u4f59\u6240\u6709\u5e38\u6d3b\u52a8\u533a\u57df\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09\u548c\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09\u600e\u4e48\u9009\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u6709\u9664\u6e7f\u521a\u9700\uff08\u6210\u90fd\u6885\u96e8\u5b63\uff09\u3001\u9700\u8981\u81ea\u6e05\u6d01\u4e0e\u7a7a\u6c14\u51c0\u5316\u3001\u8ffd\u6c42\u6781\u7b80\u7ef4\u62a4\u2192\u9009\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09\uff1b\u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\u7279\u522b\u6015\u51b7\u98ce\u76f4\u5439\u3001\u5927\u7a7a\u95f4\u65e0\u8fde\u63a5\u7387\u9650\u5236\u9700\u6c42\u2192\u9009\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09\u3002\u674e\u5973\u58eb\u5bb6\u7efc\u5408\u9664\u6e7f\u3001\u51c0\u5316\u3001\u7a33\u5b9a\u4e0e\u7ef4\u62a4\u9700\u6c42\uff0c\u63a8\u8350\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u65b9\u6848\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5\u6709\u4ec0\u4e48\u4f5c\u7528\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5\u5b89\u88c5\u5728\u70ed\u6c34\u7ba1\u8def\u56de\u6c34\u7aef\uff0c\u5c06\u7ba1\u8def\u4e2d\u7684\u51b7\u6c34\u6301\u7eed\u5faa\u73af\u56de\u6362\u70ed\u6c34\u7bb1\/\u70ed\u6c34\u5668\u91cd\u65b0\u52a0\u70ed\uff0c\u786e\u4fdd\u4efb\u4f55\u65f6\u5019\u6253\u5f00\u6c34\u9f99\u5934\u5373\u51fa\u70ed\u6c34\uff0c\u65e0\u9700\u653e\u51b7\u6c34\u7b49\u5f85\u3002\u5bf9\u56db\u5c42\u522b\u5885\u5c24\u4e3a\u91cd\u8981\u2014\u2014\u7ba1\u8def\u957f\u3001\u51b7\u6c34\u6bb5\u591a\uff0c\u5faa\u73af\u6cf5\u53ef\u8282\u6c34\u8282\u65f6\uff0c\u63d0\u5347\u4f7f\u7528\u4f53\u9a8c\u3002\u652f\u6301\u667a\u80fd\u5b9a\u65f6\u548c\u6e29\u63a7\u542f\u505c\uff0c\u8282\u80fd\u4e0d\u6d6a\u8d39\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u7cfb\u7edf\u7a33\u5b9a\u6027\u4e0e\u540e\u671f\u7ef4\u62a4\u5982\u4f55\u4fdd\u969c\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u65e5\u7acb\u5168\u5957\u8bbe\u5907\u4eab\u5382\u5bb6\u6807\u51c66\u5e74\u8d28\u4fdd\uff0c\u53c2\u4e0e\u54c1\u724c\u6708\u6d3b\u52a8\u53ef\u5ef6\u4fdd\u81f310\u5e74\uff1b\u4f1f\u661f\u7ba1\u8def\u7531\u5382\u5bb6+\u4fdd\u9669\u516c\u53f8+\u9f99\u8109\u4e09\u65b9\u8054\u4fdd50\u5e74\uff1b\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\u5bc6\u5c01\u6027\u597d\uff0c\u5185\u673a\u6807\u914d\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\u3002\u53e6\u6709\u9f99\u7684\u5341\u5e74\u80fd\u6e90\u4fdd\u969c\u670d\u52a1\uff1a10\u5e74\u5185\u56e0\u8bbe\u8ba1\u6216\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u80fd\u8017\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u8c03\u6574\uff0c\u552e\u540e\u7701\u5fc3\u3002\" }\n        }\n      ]\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548\u2161 \u5ba4\u5916\u673a RAS-280FSXPNY5Q\",\n      \"model\": \"RAS-280FSXPNY5Q\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"HITACHI \u65e5\u7acb\" },\n      \"url\": \"https:\/\/longmai-nt.com\/?page_id=1811\",\n      \"description\": \"\u884c\u4e1a\u9996\u6b3e\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u4e2d\u592e\u7a7a\u8c03\uff0c28.0kW\uff0c\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c175L\/\u5929\u9664\u6e7f\u91cf\uff0c\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0c\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a-25\u2103\u7a33\u5b9a\u8fd0\u884c\uff0c\u8986\u76d6\u4e00\u4e8c\u697c\u5e38\u5f00\u533a\u57df\u4e00\u62d6\u4e5d\u3002\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u65e5\u7acb \u5c0a\u777f\u5168\u6548\u914d\u5957\u6c34\u6a21\u5757 RWMG-280FWXNZQ\",\n      \"model\": \"RWMG-280FWXNZQ\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"HITACHI \u65e5\u7acb\" },\n      \"url\": \"https:\/\/longmai-nt.com\/?page_id=1811\",\n      \"description\": \"\u9002\u914d280\u5916\u673a\uff0c\u9a71\u52a8\u5730\u6696\u7cfb\u7edf\uff0c\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u6838\u5fc3\u7ec4\u4ef6\uff0c\u4e0d\u6253\u6298\u4ea7\u54c1\u3002\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548\u2161 \u5ba4\u5916\u673a RAS-160FSXPNY5Q\",\n      \"model\": \"RAS-160FSXPNY5Q\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"HITACHI \u65e5\u7acb\" },\n      \"url\": \"https:\/\/longmai-nt.com\/?page_id=1811\",\n      \"description\": \"\u5c0a\u777f\u5168\u654816.0kW\u673a\u578b\uff0c\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u8986\u76d6\u4e09\u56db\u697c\u5b50\u5973\u56de\u5bb6\u533a\u57df\u4e00\u62d6\u4e94\uff0c\u5b89\u88c5\u8d39\u5df2\u542b\u3002\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u65e5\u7acb \u5c0a\u777f\u5168\u6548\u914d\u5957\u6c34\u6a21\u5757 RWMG-160FWXNZQ\",\n      \"model\": \"RWMG-160FWXNZQ\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"HITACHI \u65e5\u7acb\" },\n      \"url\": \"https:\/\/longmai-nt.com\/?page_id=1811\",\n      \"description\": \"\u9002\u914d160\u5916\u673a\uff0c\u9a71\u52a8\u4e09\u56db\u697c\u5730\u6696\u7cfb\u7edf\uff0c\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u6838\u5fc3\u7ec4\u4ef6\uff0c\u4e0d\u6253\u6298\u4ea7\u54c1\u3002\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u7f8e\u56fd\u745e\u7f8e \u71c3\u6c14\u70ed\u6c34\u5668 JSQ40-LX(T)\",\n      \"model\": \"JSQ40-LX(T)\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"Rheem \u7f8e\u56fd\u745e\u7f8e\" },\n      \"description\": \"20L\/min\u5927\u5bb9\u91cf\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u4e09\u8054\u4f9b\u7cfb\u7edf\u51ac\u5b63\u91c7\u6696\u5b63\u751f\u6d3b\u70ed\u6c34\u70ed\u6e90\uff0c\u8054\u52a8150L\u6362\u70ed\u6c34\u7bb1\u4fdd\u969c\u53cc\u536b\u540c\u65f6\u4f7f\u7528\uff0c\u7ec8\u7aef\u4ef7\u4e0d\u6253\u6298\u3002\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u7f8e\u56fd\u745e\u7f8e 150\u5347\u6362\u70ed\u6c34\u7bb1\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"Rheem \u7f8e\u56fd\u745e\u7f8e\" },\n      \"description\": \"150L\u5bb9\u79ef\u5f0f\u6362\u70ed\u6c34\u7bb1\uff0c\u4e09\u8054\u4f9b\u7cfb\u7edf\u50a8\u80fd\u6838\u5fc3\uff0c\u70ed\u6cf5\u52a0\u70ed\/\u71c3\u6c14\u70ed\u6c34\u5668\u52a0\u70ed\u5747\u53ef\u50a8\u80fd\u7f13\u51b2\uff0c\u4fdd\u969c\u8fde\u7eed\u7a33\u5b9a\u70ed\u6c34\u4f9b\u5e94\u3002\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"\u5a01\u4e50 \u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5\",\n      \"brand\": { \"@type\": \"Brand\", \"name\": \"Wilo \u5a01\u4e50\" },\n      \"description\": \"\u667a\u80fd\u53d8\u9891\u70ed\u6c34\u5faa\u73af\u6cf5\uff0c\u70ed\u6c34\u7ba1\u8def\u56de\u6c34\u5faa\u73af\uff0c\u5373\u5f00\u5373\u70ed\u96f6\u7b49\u5f85\uff0c\u652f\u6301\u5b9a\u65f6\u6e29\u63a7\u542f\u505c\uff0c\u56db\u5c42\u522b\u5885\u957f\u7ba1\u8def\u5fc5\u5907\u3002\"\n    }\n  ]\n}\n<\/script>\n\n<style>\n\/* ===== \u6697\u8272\u91d1 UI \u4f53\u7cfb \u53d8\u91cf ===== *\/\n:root{\n  --lm-bg:#f6f3ec;          \/* \u6e05\u65b0\u7c73\u767d\u9875\u9762\u80cc\u666f *\/\n  --lm-bg2:#ffffff;         \/* \u5361\u7247\u80cc\u666f \u7eaf\u767d *\/\n  --lm-bg3:#f1ebdc;         \/* \u6d45\u7c73\u5757\/\u8868\u5934 *\/\n  --lm-bg4:#faf6ec;         \/* hover\/\u6d45\u5757 *\/\n  --lm-gold:#c89b3c;        \/* \u4e3b\u91d1\uff08\u6e05\u65b0\u67d4\u91d1\uff09 *\/\n  --lm-gold2:#9a7414;       \/* \u6df1\u91d1\uff08\u6d45\u5e95\u6807\u9898\u53ef\u8bfb\uff09 *\/\n  --lm-gold3:#b8860b;       \/* \u6697\u91d1 *\/\n  --lm-on-gold:#2e2616;     \/* \u91d1\u5e95\u6df1\u8272\u5b57 *\/\n  --lm-text:#3a3326;        \/* \u4e3b\u6587\u5b57 \u70ad\u68d5 *\/\n  --lm-text2:#7c7060;       \/* \u6b21\u6587\u5b57 *\/\n  --lm-border:#e6dfcd;      \/* \u8fb9\u6846 \u6d45\u7c73 *\/\n  --lm-red:#c0392b;         \/* \u5916\u94fe\u7ea2\uff08GEO\u89c4\u8303\uff09 *\/\n  --lm-green:#3f8f5f;       \/* \u4f18\u826f\/\u901a\u8fc7 *\/\n  --lm-orange:#c07d2e;      \/* \u6ce8\u610f *\/\n}\n\n\/* ===== \u5168\u5c40\u91cd\u7f6e ===== *\/\n*, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }\nhtml { scroll-behavior: smooth; }\nbody { font-family: -apple-system, \"Microsoft YaHei\", \"PingFang SC\", sans-serif; color: var(--lm-text); background: var(--lm-bg); line-height: 1.8; }\n\n\/* \u9690\u85cf WP \u81ea\u52a8\u751f\u6210\u7684\u6807\u9898 H1\uff0c\u4ec5\u4fdd\u7559\u5c01\u9762 H1\uff08F1\u4fee\u590d\uff09 *\/\n.entry-title { display: none !important; }\n\n\/* ===== \u60ac\u6d6e\u76ee\u5f55\u5bfc\u822a\uff08\u82f1\u96c4\u680f\u4e0b\u65b9 \u00b7 \u4e3b\u76ee\u5f55+\u5b50\u76ee\u5f55\uff09 ===== *\/\n\/* ===== \u60ac\u6d6e\u5bfc\u822a\uff08\u4e3b\u76ee\u5f55\u4e00\u6392 + \u5b50\u76ee\u5f55\u4e0b\u62c9\u9690\u85cf\uff09 ===== *\/\n.lm-toc-bar {\n  position: sticky; top: 0; z-index: 1000;\n  background: rgba(255,255,255,.97);\n  display: flex; align-items: stretch; flex-wrap: nowrap; gap: 2px;\n  padding: 0 14px; margin: 0 0 26px;\n  box-shadow: 0 4px 16px rgba(60,50,30,.14);\n  border-top: 3px solid var(--lm-gold); border-bottom: 1px solid var(--lm-border);\n  border-radius: 0 0 12px 12px;\n  backdrop-filter: blur(8px);\n}\n.lm-toc-group { position: relative; }\n.lm-toc-main {\n  display: inline-flex; align-items: center; gap: 4px; min-height: 48px;\n  padding: 0 14px; color: var(--lm-text); text-decoration: none;\n  font-size: 14px; font-weight: 700; letter-spacing: .2px;\n  border-bottom: 3px solid transparent; transition: all .22s; white-space: nowrap;\n}\n.lm-toc-main .lm-caret { font-size: 9px; line-height: 1; opacity: .55; transition: transform .2s; }\n.lm-toc-main:hover { color: var(--lm-gold2); background: rgba(200,155,60,.10); }\n.lm-toc-group:hover > .lm-toc-main .lm-caret,\n.lm-toc-group.lm-open > .lm-toc-main .lm-caret { transform: rotate(180deg); }\n.lm-toc-main.lm-active,\n.lm-toc-group.lm-group-active > .lm-toc-main { color: #fff; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); border-bottom-color: var(--lm-gold2); }\n.lm-toc-subs {\n  position: absolute; top: 100%; left: 0; min-width: 168px;\n  display: none; flex-direction: column; gap: 2px;\n  padding: 8px; background: rgba(255,255,255,.99);\n  border: 1px solid var(--lm-border); border-top: none; border-radius: 0 0 10px 10px;\n  box-shadow: 0 12px 26px rgba(60,50,30,.18); z-index: 1001;\n}\n.lm-toc-group:hover > .lm-toc-subs,\n.lm-toc-group.lm-open > .lm-toc-subs { display: flex; }\n.lm-toc-subs a {\n  display: block; font-size: 12.5px; color: var(--lm-text2); text-decoration: none;\n  padding: 8px 11px; border-radius: 6px; transition: all .2s; white-space: nowrap;\n}\n.lm-toc-subs a:hover { color: #fff; background: var(--lm-gold); }\n.lm-toc-subs a.lm-active { color: #fff; background: var(--lm-gold2); font-weight: 600; }\n\/* \u70b9\u51fb\u951a\u70b9\u8df3\u8f6c\u65f6\u4e3a\u60ac\u6d6e\u5bfc\u822a\u7559\u51fa\u9876\u90e8\u7a7a\u95f4 *\/\n[id] { scroll-margin-top: 64px; }\n\n\/* ===== \u4e3b\u4f53 ===== *\/\n.lm-container { max-width: 1024px; margin: 0 auto 40px; padding: 0 16px; }\n\n\/* ===== \u7ae0\u8282\u5361\u7247 ===== *\/\n.lm-section {\n  background: var(--lm-bg2); border: 1px solid var(--lm-border); border-radius: 12px;\n  padding: 40px 36px; margin-bottom: 24px; box-shadow: 0 4px 18px rgba(60,50,30,.08); position: relative;\n}\n.lm-section-title {\n  font-size: 22px; font-weight: 700; color: var(--lm-gold2);\n  padding-bottom: 12px; margin-bottom: 24px;\n  border-bottom: 3px solid var(--lm-gold); display: flex; align-items: center; gap: 10px;\n}\n.lm-section-title .lm-num {\n  display: inline-flex; align-items: center; justify-content: center;\n  width: 34px; height: 34px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3));\n  color: var(--lm-on-gold); border-radius: 50%; font-size: 14px; font-weight: 800; flex-shrink: 0;\n}\n\n\/* ===== \u8868\u683c ===== *\/\n.lm-table { width: 100%; border-collapse: collapse; margin: 16px 0 20px; font-size: 14px; }\n.lm-table th { background: var(--lm-bg3); color: var(--lm-gold2); padding: 10px 12px; text-align: center; font-weight: 600; border: 1px solid var(--lm-border); }\n.lm-table td { padding: 10px 12px; border: 1px solid var(--lm-border); text-align: center; color: var(--lm-text); }\n.lm-table tr:nth-child(even) td { background: rgba(212,160,23,.04); }\n.lm-table tr:hover td { background: rgba(212,160,23,.10); }\n.lm-table .lm-row-hl td { background: rgba(212,160,23,.12) !important; font-weight: 700; color: var(--lm-gold2); }\n\n\/* ===== \u6807\u7b7e ===== *\/\n.lm-tag { display: inline-block; padding: 2px 10px; border-radius: 4px; font-size: 12px; font-weight: 600; }\n.lm-tag-blue { background: rgba(212,160,23,.18); color: var(--lm-gold2); }\n.lm-tag-green { background: rgba(111,174,133,.18); color: var(--lm-green); }\n.lm-tag-orange { background: rgba(217,154,78,.20); color: var(--lm-orange); }\n.lm-tag-red { background: rgba(192,57,43,.12); color: #c0392b; }\n\n\/* ===== \u5bf9\u6bd4\u6846 ===== *\/\n.lm-compare-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin: 20px 0; }\n.lm-compare-card { border-radius: 10px; padding: 24px 20px; border: 2px solid var(--lm-border); position: relative; background: var(--lm-bg2); }\n.lm-compare-card.lm-recommend { border-color: var(--lm-gold); background: rgba(212,160,23,.06); }\n.lm-compare-card .lm-badge { position: absolute; top: -12px; left: 20px; padding: 2px 14px; border-radius: 20px; font-size: 12px; font-weight: 700; color: var(--lm-bg); }\n.lm-badge-rec { background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); }\n.lm-badge-comp { background: #5a4d38; color: #fff; }\n.lm-compare-card h4 { font-size: 16px; margin-bottom: 12px; color: var(--lm-gold2); }\n.lm-compare-card ul { list-style: none; padding: 0; }\n.lm-compare-card li { padding: 6px 0; font-size: 14px; border-bottom: 1px solid var(--lm-border); color: var(--lm-text); }\n.lm-compare-card li:last-child { border-bottom: none; }\n.lm-compare-card li::before { content: \"> \"; color: var(--lm-gold); font-weight: 700; }\n\n\/* ===== \u9ad8\u4eae\u6846 ===== *\/\n.lm-highlight { background: rgba(212,160,23,.10); border-left: 4px solid var(--lm-gold); padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n.lm-highlight-blue { background: rgba(77,140,200,.10); border-left: 4px solid #4d8cc8; padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n.lm-highlight-green { background: rgba(111,174,133,.10); border-left: 4px solid var(--lm-green); padding: 14px 18px; border-radius: 6px; margin: 16px 0; font-size: 14px; color: var(--lm-text); }\n\n\/* ===== \u4fe1\u606f\u5361 ===== *\/\n.lm-info-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 12px; margin: 16px 0; }\n.lm-info-item { background: var(--lm-bg3); border: 1px solid var(--lm-border); border-radius: 8px; padding: 14px 16px; text-align: center; }\n.lm-info-item .lm-label { font-size: 12px; color: var(--lm-text2); margin-bottom: 4px; }\n.lm-info-item .lm-value { font-size: 18px; font-weight: 700; color: var(--lm-gold2); }\n\n\/* ===== \u6b65\u9aa4\u6d41 ===== *\/\n.lm-step-flow { display: flex; flex-wrap: wrap; gap: 8px; margin: 16px 0; }\n.lm-step-flow .lm-step { background: var(--lm-bg3); border: 1px solid var(--lm-border); padding: 8px 16px; border-radius: 20px; font-size: 13px; color: var(--lm-text2); }\n\n\/* ===== \u7cbe\u5de5\u516d\u6b65\u6cd5 \u8f6e\u64ad ===== *\/\n.lm-carousel { position: relative; margin: 18px 0 8px; border-radius: 12px; overflow: hidden; background: var(--lm-bg2); border: 1px solid var(--lm-border); }\n.lm-carousel-track { display: flex; transition: transform .55s cubic-bezier(.4,0,.2,1); }\n.lm-slide { min-width: 100%; }\n.lm-cs-head { display: flex; align-items: center; gap: 12px; padding: 16px 20px; background: linear-gradient(90deg, var(--lm-bg3), var(--lm-bg4)); color: var(--lm-gold2); border-bottom: 1px solid var(--lm-border); }\n.lm-cs-num { background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); font-weight: 800; font-size: 15px; width: 32px; height: 32px; border-radius: 50%; display: flex; align-items: center; justify-content: center; flex-shrink: 0; }\n.lm-cs-title { font-size: 17px; font-weight: 700; }\n.lm-cs-body { padding: 16px 20px 6px; font-size: 14px; line-height: 1.8; color: var(--lm-text); }\n.lm-cs-std { padding: 6px 20px 14px; font-size: 13px; color: var(--lm-gold2); }\n.lm-cs-std b { color: var(--lm-gold2); }\n.lm-cs-imgs { padding: 0 20px 18px; display: flex; gap: 14px; flex-wrap: wrap; align-items: flex-start; }\n.lm-cs-imgs img { width: 300px; height: 210px; object-fit: cover; border-radius: 8px; border: 1px solid var(--lm-border); display: block; }\n.lm-cs-imgs .lm-cap { font-size: 12px; color: var(--lm-text2); margin-top: 4px; text-align: center; }\n.lm-cs-imgs figure { margin: 0; }\n\/* \u5355\u56fe\u5b8c\u6574\u5c55\u793a\uff0c\u4e0d\u88c1\u5207\u3001\u4fdd\u6e05\u6670 *\/\n.lm-cs-imgs figure:only-child { flex: 1 1 100%; }\n.lm-cs-imgs figure:only-child img { width: 100%; height: auto; max-height: 480px; object-fit: contain; background: var(--lm-bg3); }\n.lm-car-arrow { position: absolute; top: 50%; transform: translateY(-50%); width: 42px; height: 42px; background: rgba(200,155,60,.88); border: none; border-radius: 50%; font-size: 24px; line-height: 1; color: var(--lm-on-gold); cursor: pointer; display: flex; align-items: center; justify-content: center; transition: all .25s; z-index: 3; box-shadow: 0 2px 8px rgba(0,0,0,.18); }\n.lm-car-arrow:hover { background: var(--lm-gold); }\n.lm-car-arrow.lm-prev { left: 12px; }\n.lm-car-arrow.lm-next { right: 12px; }\n.lm-car-dots { position: absolute; bottom: 12px; left: 0; right: 0; display: flex; gap: 8px; justify-content: center; z-index: 3; }\n.lm-car-dots .lm-dot { width: 9px; height: 9px; border-radius: 50%; background: rgba(154,116,20,.30); cursor: pointer; transition: all .25s; }\n.lm-car-dots .lm-dot.lm-active { background: var(--lm-gold); width: 22px; border-radius: 5px; }\n\n\/* ===== \u65b9\u6848\u8bbe\u8ba1\u00b7\u4ea7\u54c1\u5361\u7247 ===== *\/\n.lm-prod-showcase { display: flex; gap: 16px; flex-wrap: wrap; margin: 18px 0; }\n.lm-prod-card { flex: 0 0 auto; width: 320px; border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; background: var(--lm-bg2); box-shadow: 0 2px 10px rgba(60,50,30,.10); }\n.lm-prod-card img { width: 100%; height: 200px; object-fit: cover; display: block; }\n.lm-prod-card .lm-pc-body { padding: 12px 14px 14px; }\n.lm-prod-card .lm-pc-title { font-size: 14px; font-weight: 600; color: var(--lm-gold2); margin-bottom: 4px; }\n.lm-prod-card .lm-pc-desc { font-size: 12px; color: var(--lm-text2); margin-bottom: 10px; line-height: 1.6; }\n.lm-prod-card .lm-pc-link { display: inline-block; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); font-size: 13px; font-weight: 600; padding: 6px 16px; border-radius: 20px; text-decoration: none; }\n.lm-prod-card .lm-pc-link:hover { background: var(--lm-gold2); }\n\n\/* ===== Tabs\uff08\u7cfb\u7edf\u5bf9\u6bd4\uff09 ===== *\/\n.lm-tabs-nav { display: flex; gap: 0; margin: 18px 0 0; border-bottom: 2px solid var(--lm-border); flex-wrap: wrap; }\n.lm-tab-btn { background: var(--lm-bg3); color: var(--lm-text2); border: 1px solid var(--lm-border); border-bottom: none; padding: 10px 22px; font-size: 14px; font-weight: 600; cursor: pointer; transition: all .25s; border-radius: 8px 8px 0 0; margin-right: 4px; }\n.lm-tab-btn:hover { color: var(--lm-gold2); }\n.lm-tab-btn.lm-active { background: var(--lm-gold); color: var(--lm-on-gold); border-color: var(--lm-gold); }\n.lm-tab-panel { display: none; padding: 8px 0; }\n.lm-tab-panel.lm-active { display: block; animation: lmFade .3s; }\n@keyframes lmFade { from { opacity: 0; } to { opacity: 1; } }\n\n\/* ===== \u624b\u98ce\u7434\uff08\u8f85\u6750\u6e05\u5355\uff09 ===== *\/\n.lm-acc { margin: 16px 0; border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; }\n.lm-acc-item { border-bottom: 1px solid var(--lm-border); }\n.lm-acc-item:last-child { border-bottom: none; }\n.lm-acc-head { display: flex; align-items: center; justify-content: space-between; padding: 14px 18px; background: var(--lm-bg3); cursor: pointer; font-size: 15px; font-weight: 600; color: var(--lm-gold2); transition: background .2s; user-select: none; }\n.lm-acc-head:hover { background: var(--lm-bg4); }\n.lm-acc-head .lm-acc-ico { color: var(--lm-gold); font-size: 18px; transition: transform .3s; }\n.lm-acc-item.lm-open .lm-acc-head .lm-acc-ico { transform: rotate(45deg); }\n.lm-acc-body { max-height: 0; overflow: hidden; transition: max-height .4s ease; background: var(--lm-bg2); }\n.lm-acc-item.lm-open .lm-acc-body { max-height: 1200px; }\n.lm-acc-body-inner { padding: 4px 18px 18px; }\n\n\/* ===== \u56fe\u8868 ===== *\/\n.lm-chart-box { background: var(--lm-bg2); border: 1px solid var(--lm-border); border-radius: 10px; padding: 16px; margin: 20px 0; }\n.lm-chart-box .lm-chart-title { font-size: 15px; font-weight: 600; color: var(--lm-gold2); margin-bottom: 10px; }\n.lm-chart { width: 100%; height: 340px; }\n\n\/* ===== \u6848\u4f8b\u5185\u94fe ===== *\/\n.lm-case-link { color: var(--lm-gold2); font-weight: 600; text-decoration: none; border-bottom: 1px dashed var(--lm-gold); }\n.lm-case-link:hover { color: var(--lm-gold); border-bottom-color: var(--lm-gold2); }\n.lm-case-link::after { content: \" \u2197\"; font-size: 11px; color: var(--lm-gold); }\n\n\/* ===== \u4e09\u56fe\u5e76\u6392 ===== *\/\n.lm-img-row { display: flex; gap: 16px; margin: 20px 0; flex-wrap: wrap; }\n.lm-img-row .lm-img-card { flex: 1; min-width: 200px; border-radius: 10px; overflow: hidden; box-shadow: 0 2px 10px rgba(60,50,30,.10); background: var(--lm-bg2); text-align: center; border: 1px solid var(--lm-border); }\n.lm-img-row .lm-img-card img { width: 100%; height: auto; display: block; }\n.lm-img-row .lm-img-card .lm-img-label { padding: 8px 10px; font-size: 13px; color: var(--lm-gold2); background: var(--lm-bg3); border-top: 1px solid var(--lm-border); }\n\n\/* ===== \u5c01\u9762\uff08\u82f1\u96c4\u680f\uff09 ===== *\/\n.lm-cover {\n  text-align: center; padding: 90px 36px 80px; position: relative; overflow: hidden;\n  color: #fff;\n  background-image:\n    linear-gradient(135deg, rgba(20,16,8,.80) 0%, rgba(40,30,15,.58) 50%, rgba(20,16,8,.82) 100%),\n    url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-yxl-zrqxyxl.jpg');\n  background-size: cover; background-position: center center; background-repeat: no-repeat;\n  min-height: 480px; display: flex; flex-direction: column; justify-content: center;\n  border: 1px solid var(--lm-border); border-radius: 12px; margin-bottom: 24px; box-shadow: 0 4px 18px rgba(0,0,0,.35);\n}\n.lm-cover::before {\n  content: \"\"; position: absolute; top: 0; left: 0; right: 0; height: 6px; z-index: 2;\n  background: linear-gradient(90deg, var(--lm-gold), var(--lm-gold2), var(--lm-gold));\n}\n.lm-cover::after {\n  content: \"\"; position: absolute; bottom: 0; left: 0; right: 0; height: 80px;\n  background: linear-gradient(180deg, transparent, rgba(20,16,8,.6)); pointer-events: none;\n}\n.lm-cover > * { position: relative; z-index: 1; }\n.lm-cover h1 { font-size: 38px; color: #fff; margin-bottom: 12px; text-shadow: 0 2px 12px rgba(0,0,0,.7); letter-spacing: 1px; }\n.lm-cover .lm-sub { font-size: 20px; color: #e8dcc0; margin-bottom: 24px; text-shadow: 0 1px 6px rgba(0,0,0,.6); font-weight: 300; }\n.lm-cover .lm-meta { display: flex; justify-content: center; gap: 28px; flex-wrap: wrap; font-size: 14px; color: #d8c8a8; margin-top: 20px; }\n.lm-cover .lm-meta span { background: rgba(212,160,23,.14); padding: 6px 14px; border-radius: 20px; backdrop-filter: blur(4px); border: 1px solid rgba(212,160,23,.35); }\n.lm-cover .lm-meta .lm-brand-tag { background: rgba(212,160,23,.22); color: var(--lm-gold2); font-weight: 600; border: 1px solid rgba(212,160,23,.5); }\n\n\/* ===== \u95e8\u5e97\/\u8054\u7cfb\u4fe1\u606f\u9875\u811a ===== *\/\n.lm-contact-footer { padding: 0; }\n.lm-cf-header { text-align: center; padding: 32px 24px 20px; border-bottom: 1px solid var(--lm-border); }\n.lm-cf-header .lm-cf-title { font-size: 22px; font-weight: 700; color: var(--lm-gold2); display: flex; align-items: center; justify-content: center; gap: 8px; }\n.lm-cf-header .lm-cf-title .lm-phone-icon { color: var(--lm-gold); font-size: 24px; }\n.lm-cf-header .lm-cf-sub { font-size: 14px; color: var(--lm-text2); margin-top: 8px; }\n\n.lm-cf-contacts { display: grid; grid-template-columns: repeat(4, 1fr); gap: 12px; padding: 20px 24px; }\n.lm-cf-contact { display: flex; align-items: center; gap: 10px; padding: 12px 16px; border: 1px solid var(--lm-border); border-radius: 8px; background: var(--lm-bg3); transition: all .25s; text-decoration: none; }\n.lm-cf-contact:hover { border-color: var(--lm-gold); background: rgba(212,160,23,.08); }\n.lm-cf-contact .lm-ic { width: 32px; height: 32px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); border-radius: 8px; display: flex; align-items: center; justify-content: center; font-size: 16px; flex-shrink: 0; }\n.lm-cf-contact .lm-info { display: flex; flex-direction: column; }\n.lm-cf-contact .lm-label { font-size: 12px; color: var(--lm-text2); }\n.lm-cf-contact .lm-phone { font-size: 15px; font-weight: 700; color: var(--lm-gold2); }\n\n.lm-cf-services { display: grid; grid-template-columns: repeat(4, 1fr); gap: 8px; padding: 0 24px 20px; }\n.lm-cf-service { display: flex; align-items: center; gap: 6px; padding: 8px 12px; background: var(--lm-bg3); border-radius: 6px; font-size: 13px; color: var(--lm-text); }\n.lm-cf-service .lm-ck { color: var(--lm-green); font-weight: 700; font-size: 14px; }\n\n.lm-cf-stores { display: grid; grid-template-columns: 1fr 1fr; gap: 16px; padding: 0 24px 20px; }\n.lm-cf-store { border: 1px solid var(--lm-border); border-radius: 10px; overflow: hidden; background: var(--lm-bg2); }\n.lm-cf-store .lm-store-label { padding: 8px 14px; background: var(--lm-bg3); font-size: 14px; font-weight: 600; color: var(--lm-gold2); display: flex; align-items: center; gap: 6px; border-bottom: 1px solid var(--lm-border); }\n.lm-cf-store .lm-store-label .lm-pin { color: var(--lm-gold); }\n.lm-cf-store img { width: 100%; height: 200px; object-fit: cover; display: block; }\n.lm-cf-store .lm-store-addr { padding: 10px 14px; font-size: 13px; color: var(--lm-text2); display: flex; gap: 6px; align-items: flex-start; }\n.lm-cf-store .lm-store-addr .lm-pin { color: var(--lm-gold); flex-shrink: 0; }\n\n.lm-cf-service-area { text-align: center; padding: 16px 24px; font-size: 13px; color: var(--lm-text); border-top: 1px solid var(--lm-border); border-bottom: 1px solid var(--lm-border); background: var(--lm-bg3); }\n.lm-cf-service-area .lm-label { font-weight: 600; color: var(--lm-gold2); margin-right: 8px; }\n\n.lm-cf-cta { text-align: center; padding: 24px; }\n.lm-cf-cta .lm-btn { display: inline-flex; align-items: center; gap: 6px; padding: 12px 36px; background: linear-gradient(135deg, var(--lm-gold), var(--lm-gold3)); color: var(--lm-on-gold); border-radius: 30px; font-size: 15px; font-weight: 700; text-decoration: none; box-shadow: 0 4px 14px rgba(200,155,60,.30); transition: all .25s; }\n.lm-cf-cta .lm-btn:hover { background: var(--lm-gold2); transform: translateY(-1px); }\n\n.lm-cf-footer-note { text-align: center; padding: 12px 24px 24px; font-size: 12px; color: var(--lm-text2); }\n\n\/* \u5916\u94fe\u7ea2\uff08GEO\u6280\u672f\u89c4\u8303\uff09\uff1a\u5916\u90e8\u7ad9\u70b9\u94fe\u63a5\u7ea2\u8272\u52a0\u4e0b\u5212\u7ebf *\/\na[href*=\"\/\/\"]:not([href*=\"longmai-nt.com\"]) { color: var(--lm-red); text-decoration: underline; }\n\n@media (max-width: 768px) {\n  .lm-cf-contacts, .lm-cf-services { grid-template-columns: 1fr 1fr; }\n  .lm-cf-stores { grid-template-columns: 1fr; }\n  .lm-cf-store img { height: 160px; }\n  .lm-compare-grid { grid-template-columns: 1fr; }\n  .lm-container { margin-top: 60px; padding: 0 10px; }\n  .lm-section { padding: 24px 16px; }\n  .lm-cover h1 { font-size: 24px; }\n  .lm-toc-bar { padding: 0 8px; margin: 0 0 18px; overflow-x: auto; backdrop-filter: none; -webkit-backdrop-filter: none; }\n  .lm-toc-bar::-webkit-scrollbar { height: 0; }\n  .lm-toc-main { font-size: 12.5px; padding: 0 10px; min-height: 46px; }\n  .lm-toc-main .lm-caret { font-size: 8px; }\n  .lm-toc-subs { position: fixed; top: 49px; left: 8px; right: 8px; min-width: 0; flex-direction: row; flex-wrap: wrap; gap: 4px; }\n  .lm-toc-subs a { font-size: 12px; padding: 7px 10px; }\n  .lm-table { font-size: 12px; }\n  .lm-table th, .lm-table td { padding: 6px 8px; }\n  .lm-info-grid { grid-template-columns: 1fr 1fr; }\n  .lm-cs-imgs img { width: 200px; height: 140px; }\n  .lm-cs-imgs figure:only-child img { width: 100%; height: auto; max-height: 320px; object-fit: contain; }\n}\n<\/style>\n\n<!-- \u65e7\u56fa\u5b9a\u5bfc\u822a\u5df2\u79fb\u9664\uff0c\u5bfc\u822a\u73b0\u4f4d\u4e8e\u82f1\u96c4\u680f\u4e0b\u65b9\uff08\u5c01\u9762\u4e4b\u540e\uff09 -->\n\n<div class=\"lm-container\">\n\n<!-- ===== \u5c01\u9762 ===== -->\n<section class=\"lm-section lm-cover\" id=\"cover\">\n  \n  <p class=\"lm-sub\">\u8212\u9002\u5065\u5eb7 \u00b7 \u8282\u80fd\u7a33\u5b9a \u00b7 \u7ef4\u62a4\u7b80\u4fbf<\/p>\n  <div class=\"lm-meta\" id=\"cover-meta\">\n    <span>\u5ba2\u6237\u6863\u6848\u53f7\uff1aKH-2026-0395<\/span>\n    <span>\u5ba2\u6237\uff1a\u9f99\u6e56\u5149\u5e74 \u00b7 \u674e\u5973\u58eb<\/span>\n    <span>\u5c0f\u533a\uff1a\u9f99\u6e56\u5149\u5e74 \u00b7 \u522b\u5885\u56db\u5c42<\/span>\n    <span>\u7269\u4e1a\u7c7b\u578b\uff1a\u522b\u5885\uff081F-4F \u51714\u5c42\uff09<\/span>\n    <span>\u91c7\u6696\u9762\u79ef\u7ea6\uff1a380 \u33a1\uff08\u5730\u6696\u94fa\u8bbe 370 \u33a1\uff09<\/span>\n    <span>\u5e38\u4f4f\u4eba\u53e3\uff1a4-5 \u4eba<\/span>\n    <span>\u65b9\u6848\u987e\u95ee\uff1a\u4f59\u6653\u73b2\uff0822\u5e74\u4ece\u4e1a\uff09<\/span>\n    <span>\u6e20\u9053\uff1a\u8001\u5ba2\u6237\u63a8\u8350<\/span>\n    <span>\u65e5\u671f\uff1a2026\u5e748\u670813\u65e5\uff08\u4fee\u8ba2\uff09<\/span>\n  <\/div>\n  <div class=\"lm-meta\" style=\"margin-top:8px;\">\n    <span class=\"lm-brand-tag\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u8bb8\u7ecf\u9500\u5546<\/span>\n  <\/div>\n<\/section>\n\n<!-- ========== \u60ac\u6d6e\u76ee\u5f55\u5bfc\u822a\uff08\u82f1\u96c4\u680f\u4e0b\u65b9 \u00b7 \u4e3b\u76ee\u5f55+\u5b50\u76ee\u5f55\uff09 ========== -->\n<nav class=\"lm-toc-bar\" id=\"lmToc\">\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main lm-active\" href=\"#cover\">\u5c01\u9762<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\"><a href=\"#cover-meta\">\u9879\u76ee\u4fe1\u606f<\/a><\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#s1\">S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\">\n      <a href=\"#s1-pain\">\u73b0\u72b6\u75db\u70b9<\/a>\n      <a href=\"#s1-need\">\u6838\u5fc3\u8bc9\u6c42<\/a>\n      <a href=\"#s1-diag\">\u8bca\u65ad\u5206\u6790<\/a>\n      <a href=\"#s1-zone\">\u53cc\u7cfb\u7edf\u5206\u533a<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#s2\">S2\u00b7\u65b9\u6848\u8bca\u65ad<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\">\n      <a href=\"#s2-five\">\u4e09\u8054\u4f9b\u4f53\u9a8c<\/a>\n      <a href=\"#s2-scene\">\u9002\u7528\u60c5\u666f<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#s3\">S3\u00b7\u7cfb\u7edf\u8bbe\u8ba1<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\">\n      <a href=\"#s3-arch\">\u67b6\u6784\u603b\u89c8<\/a>\n      <a href=\"#s3-u1\">\u5185\u673a\u660e\u7ec6<\/a>\n      <a href=\"#s3-floor\">\u5730\u6696\u7cfb\u7edf<\/a>\n      <a href=\"#s3-craft\">\u7cbe\u5de5\u65bd\u5de5<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#s4\">S4\u00b7\u900f\u660e\u62a5\u4ef7<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\">\n      <a href=\"#s4-s1\">\u7cfb\u7edf\u4e00<\/a>\n      <a href=\"#s4-s2\">\u7cfb\u7edf\u4e8c<\/a>\n      <a href=\"#s4-sum\">\u6c47\u603b<\/a>\n      <a href=\"#s4-mat\">\u8f85\u6750\u6e05\u5355<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#s5\">S5\u00b7\u6848\u4f8b\u9a8c\u8bc1<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\"><a href=\"#s5\">\u6807\u6746\u6848\u4f8b<\/a><\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#sa\">\u9644\u5f55\u00b7\u54c1\u724c\u6388\u6743<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\"><a href=\"#sa-cert\">\u6388\u6743\u8bc1\u4e66<\/a><\/div>\n  <\/div>\n  <div class=\"lm-toc-group\">\n    <a class=\"lm-toc-main\" href=\"#s10\">\u8054\u7cfb\u6211\u4eec<span class=\"lm-caret\">\u25be<\/span><\/a>\n    <div class=\"lm-toc-subs\"><a href=\"#s10-contact\">\u8054\u7cfb\u65b9\u5f0f<\/a><\/div>\n  <\/div>\n<\/nav>\n\n<!-- ===== S1\u00b7\u5ba2\u6237\u6210\u529f\u76ee\u6807 ===== -->\n<section class=\"lm-section\" id=\"s1\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S1<\/span>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n\n  <h3 style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n  <div class=\"lm-info-grid\">\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5ba2\u6237\u6863\u6848\u53f7<\/div><div class=\"lm-value\">KH-2026-0395<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5ba2\u6237<\/div><div class=\"lm-value\">\u9f99\u6e56\u5149\u5e74 \u00b7 \u674e\u5973\u58eb<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5c0f\u533a<\/div><div class=\"lm-value\">\u9f99\u6e56\u5149\u5e74 \u00b7 \u522b\u5885\u56db\u5c42<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5efa\u7b51\u5c42\u6570<\/div><div class=\"lm-value\">1F ~ 4F\uff08\u51714\u5c42\uff09<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u91c7\u6696\u9762\u79ef<\/div><div class=\"lm-value\">\u7ea6 380 \u33a1\uff08\u5730\u6696\u94fa\u8bbe 370 \u33a1\uff09<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5e38\u4f4f\u4eba\u53e3<\/div><div class=\"lm-value\">4-5 \u4eba<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u65b9\u6848\u987e\u95ee<\/div><div class=\"lm-value\">\u4f59\u6653\u73b2\uff0822\u5e74\u4ece\u4e1a\uff09<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u6e20\u9053<\/div><div class=\"lm-value\">\u8001\u5ba2\u6237\u63a8\u8350<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u4f7f\u7528\u7279\u5f81<\/div><div class=\"lm-value\">1-2F\u5e38\u5f00\u00b73-4F\u5076\u7528<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5ba2\u6237\u4e60\u60ef<\/div><div class=\"lm-value\">\u56db\u5b63\u5f00\u7a97\u901a\u98ce<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u7cfb\u7edf\u76ee\u6807<\/div><div class=\"lm-value\">\u4e09\u8054\u4f9b\uff08\u5236\u51b7\u00b7\u91c7\u6696\u00b7\u70ed\u6c34\uff09<\/div><\/div>\n  <\/div>\n\n  <h3 id=\"s1-pain\" style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u73b0\u72b6\u75db\u70b9\uff08\u539f\u522b\u5885\u5176\u4ed6\u54c1\u724c\u7a7a\u8c03\uff09<\/h3>\n  <div class=\"lm-highlight\"><strong>\u674e\u5973\u58eb\u539f\u522b\u5885\u5b89\u88c5\u7684\u662f\u5176\u4ed6\u54c1\u724c\u7a7a\u8c03\uff0c\u4f7f\u7528\u4e2d\u66b4\u9732\u4e09\u5927\u75db\u70b9\uff1a<\/strong><\/div>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:12%;\">\u5e8f\u53f7<\/th><th style=\"width:30%;\">\u75db\u70b9<\/th><th style=\"width:58%;\">\u5177\u4f53\u8868\u73b0<\/th><\/tr>\n    <tr><td>\u2460<\/td><td><strong>\u566a\u97f3\u504f\u5927<\/strong><\/td><td>\u539f\u7a7a\u8c03\u5185\u673a\u8fd0\u884c\u566a\u97f3\u504f\u9ad8\uff0c\u591c\u95f4\u5f71\u54cd\u7761\u7720\uff0c\u5c24\u5176\u5367\u5ba4\u96be\u4ee5\u5b89\u9759\u4f11\u606f<\/td><\/tr>\n    <tr><td>\u2461<\/td><td><strong>\u98ce\u5927\u3001\u5439\u5f97\u4e0d\u8212\u9002<\/strong><\/td><td>\u51fa\u98ce\u76f4\u5439\u3001\u8d8a\u5439\u8d8a\u51b7\uff0c\u4f53\u611f\u5e72\u51b7\u4e0d\u5747\uff0c\u5b58\u5728\u660e\u663e\u51b7\u98ce\u6b7b\u89d2\u4e0e\u8fc7\u51b7\u4e0d\u9002<\/td><\/tr>\n    <tr><td>\u2462<\/td><td><strong>\u80fd\u8017\u9ad8<\/strong><\/td><td>\u51ac\u5b63\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u7ea6 <strong>15,000 \u5143\/\u5e74<\/strong>\uff0c\u957f\u671f\u4f7f\u7528\u6210\u672c\u9ad8<\/td><\/tr>\n  <\/table>\n\n  <h3 id=\"s1-need\" style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u6838\u5fc3\u8bc9\u6c42\uff08\u6210\u529f\u76ee\u6807 \u00b7 \u91cf\u5316\uff09<\/h3>\n  <div class=\"lm-highlight\"><strong>\u674e\u5973\u58eb\u5bf9\u5168\u65b0\u7cfb\u7edf\u7684\u4e94\u9879\u91cf\u5316\u8981\u6c42\uff1a<\/strong><\/div>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:12%;\">\u5e8f\u53f7<\/th><th style=\"width:30%;\">\u8bc9\u6c42<\/th><th style=\"width:58%;\">\u91cf\u5316\u76ee\u6807<\/th><\/tr>\n    <tr><td>\u2460<\/td><td><strong>\u566a\u97f3\u5c0f<\/strong><\/td><td>\u5185\u673a\u8fd0\u884c\u566a\u97f3 \u2264 30dB\uff08\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\uff09<\/td><\/tr>\n    <tr><td>\u2461<\/td><td><strong>\u51fa\u98ce\u67d4\u548c<\/strong><\/td><td>\u907f\u514d\u76f4\u5439\u8fc7\u51b7\uff0c\u6e29\u5ea6\u5747\u5300\u65e0\u6b7b\u89d2<\/td><\/tr>\n    <tr><td>\u2462<\/td><td><strong>\u4e09\u8054\u4f9b\u70ed\u6c34<\/strong><\/td><td>\u5ef6\u5c55\u4e8c\u8054\u4f9b\u4e3a\u4e09\u8054\u4f9b\uff0c\u590f\u5b63\u70ed\u6cf5\u4f9b\u70ed\u6c34\u7701\u6c14\u8d39\uff0c\u51ac\u5b63\u70ed\u6c34\u5668\u8054\u52a8\u6c34\u7bb1\u4fdd\u969c\u53cc\u536b\u540c\u65f6\u4f7f\u7528<\/td><\/tr>\n    <tr><td>\u2463<\/td><td><strong>\u6574\u4f53\u8282\u80fd<\/strong><\/td><td>\u5168\u5e74\u8fd0\u884c\u8d39\u8f83\u73b0\u72b6 15,000 \u5143\/\u5e74\u91c7\u6696\u57fa\u51c6\u663e\u8457\u4e0b\u964d\uff0c\u5c0f\u533a\u6c14\u8d394\u5143+\/m\u00b3\uff0c\u4f18\u5148\u7a7a\u6c14\u80fd\u4f9b\u70ed\u6c34<\/td><\/tr>\n    <tr><td>\u2464<\/td><td><strong>\u8212\u9002\u5065\u5eb7<\/strong><\/td><td>\u6052\u6e29\u6052\u6e7f\u6052\u9759\uff0c\u70ed\u6c34\u5145\u8db3\u5373\u5f00\u5373\u6765\uff0c\u5ba2\u6237\u4e60\u60ef\u56db\u5b63\u5f00\u7a97\u81ea\u7136\u901a\u98ce<\/td><\/tr>\n  <\/table>\n\n  <h3 id=\"s1-diag\" style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u8bca\u65ad\u5206\u6790\uff08\u75db\u70b9 \u2192 \u8bc9\u6c42 \u2192 \u4e09\u8054\u4f9b\u5e94\u5bf9\uff09<\/h3>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:18%;\">\u539f\u75db\u70b9<\/th><th style=\"width:20%;\">\u5bf9\u5e94\u8bc9\u6c42<\/th><th style=\"width:16%;\">\u7cfb\u7edf\u6620\u5c04<\/th><th style=\"width:46%;\">\u5e94\u5bf9\u7b56\u7565<\/th><\/tr>\n    <tr><td>\u566a\u97f3\u504f\u5927<\/td><td>\u2460 \u566a\u97f3\u226430dB<\/td><td>\u6052\u9759<\/td><td>\u5c0a\u777f\u5168\u6548\u5185\u673a\u6700\u4f4e17dB\uff0c\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\u226430dB<\/td><\/tr>\n    <tr><td>\u98ce\u5927\u76f4\u5439\u8fc7\u51b7<\/td><td>\u2461 \u51fa\u98ce\u67d4\u548c<\/td><td>\u6052\u6e29<\/td><td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u67d4\u548c\u9001\u98ce\uff0c\u5206\u533a\u63a7\u6e29\u5747\u5300\u65e0\u6b7b\u89d2<\/td><\/tr>\n    <tr><td>\u80fd\u8017\u9ad8\uff0815000\/\u5e74\uff09<\/td><td>\u2463 \u6574\u4f53\u8282\u80fd<\/td><td>\u2014<\/td><td>\u5929\u6c1f\u5730\u6c34\u7a7a\u6c14\u80fdCOP\u22653.0 + 280\/160\u53cc\u7cfb\u7edf\u5206\u533a\u542f\u505c\uff0c\u8f83\u73b0\u72b6\u663e\u8457\u4e0b\u964d<\/td><\/tr>\n    <tr><td>\u70ed\u6c34\u9700\u6c42\u5927\uff08\u53cc\u536b+\u591a\u4ee3\u540c\u5802\uff09<\/td><td>\u2462 \u4e09\u8054\u4f9b\u70ed\u6c34<\/td><td>\u2014<\/td><td>\u5ef6\u5c55\u4e8c\u8054\u4f9b\u4e3a\u4e09\u8054\u4f9b\uff1a\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1+\u5a01\u4e50\u5faa\u73af\u6cf5+\u745e\u7f8eJSQ40-LX(T)\u70ed\u6c34\u5668\uff0c\u590f\u5b63\u70ed\u6cf5\u4f9b\u70ed\u6c34\u7701\u6c14\uff0c\u51ac\u5b63\u70ed\u6c34\u5668\u8054\u52a8\u6c34\u7bb1\u4fdd\u969c\u53cc\u536b\u540c\u65f6\u4f7f\u7528<\/td><\/tr>\n    <tr><td>\u5c0f\u533a\u6c14\u8d39\u8d35\uff084\u5143+\/m\u00b3\uff09<\/td><td>\u2463 \u6574\u4f53\u8282\u80fd<\/td><td>\u2014<\/td><td>\u5168\u5e74\u5927\u90e8\u5206\u65f6\u95f4\u7528\u7a7a\u6c14\u80fd\u70ed\u6cf5\u4f9b\u70ed\u6c34\uff08COP\u22653.0\uff09\uff0c\u4ec5\u51ac\u5b63\u91c7\u6696\u5b63\u542f\u7528\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u5927\u5e45\u964d\u4f4e\u71c3\u6c14\u8d39\u7528<\/td><\/tr>\n    <tr><td>\u5ba2\u6237\u4e60\u60ef\u56db\u5b63\u5f00\u7a97<\/td><td>\u2464 \u8212\u9002\u5065\u5eb7<\/td><td>\u2014<\/td><td>\u5c0a\u91cd\u5ba2\u6237\u4f7f\u7528\u4e60\u60ef\uff0c\u4e0d\u914d\u7f6e\u65b0\u98ce\u7cfb\u7edf\uff08\u81ea\u7136\u901a\u98ce\u5df2\u6ee1\u8db3\u6362\u6c14\u9700\u6c42\uff09\uff0c\u4e0d\u914d\u7f6e\u96c6\u63a7\u5c4f\uff08\u5404\u5185\u673a\u72ec\u7acb\u7ebf\u63a7\u5668\u64cd\u63a7\uff09<\/td><\/tr>\n    <tr><td>\u697c\u5c42\u4f7f\u7528\u9891\u7387\u5dee\u5f02\u5927<\/td><td>\u2463 \u6574\u4f53\u8282\u80fd<\/td><td>\u2014<\/td><td>280\uff08\u5e38\u5f00\uff09+160\uff08\u5076\u7528\uff09\u53cc\u7cfb\u7edf\u72ec\u7acb\u542f\u505c\uff0c\u5b50\u5973\u4e0d\u5728\u5bb6\u65f6\u4e09\u56db\u697c\u5173\u673a<\/td><\/tr>\n    <tr><td>\u6210\u90fd\u9ad8\u6e7f\u6885\u96e8\u5b63<\/td><td>\u2464 \u8212\u9002\u5065\u5eb7<\/td><td>\u6052\u6e7f<\/td><td>\u4e09\u7ba1\u5236\u72ec\u7acb\u4e0d\u964d\u6e29\u9664\u6e7f\uff08175L\/\u5929\uff09\uff0c\u4e0d\u9760\u5236\u51b7\u9664\u6e7f\u5e26\u6765\u7684\u8fc7\u51b7<\/td><\/tr>\n  <\/table>\n\n  <h3 id=\"s1-zone\" style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u53cc\u7cfb\u7edf\u5206\u533a\u8bbe\u8ba1\u5206\u6790<\/h3>\n  <div class=\"lm-highlight-blue\">\n    <strong>\u5173\u4e8e\"\u4e00\u5957\u8d85\u5927\u5916\u673a vs \u4e24\u5957\u5206\u533a\u7cfb\u7edf\"\u7684\u7814\u5224\uff1a<\/strong><br>\n    \u82e5\u91c7\u7528\u5355\u53f0\u8d85\u5927\u5916\u673a\u62d614\u53f0\u5185\u673a\uff0c\u521d\u6295\u8d44\u9ad8\u3001\u65e5\u5e38\u4ec5\u5f00\u4e00\u4e8c\u697c\u65f6\u5927\u7cfb\u7edf\u957f\u671f\u4f4e\u9891\u7a7a\u8017\u3001\u80fd\u6548\u5dee\uff1b<br>\n    \u672c\u6848\u91c7\u7528<strong>\u5c0a\u777f\u5168\u6548280\uff081F-2F\u5e38\u5f00\u533a\uff0c\u4e00\u62d6\u4e5d\uff09+ \u5c0a\u777f\u5168\u6548160\uff083F-4F\u5b50\u5973\u56de\u5bb6\u533a\uff0c\u4e00\u62d6\u4e94\uff09<\/strong>\u53cc\u7cfb\u7edf\u5206\u533a\uff1a<br>\n    1. <strong>\u521d\u6295\u8d44\u66f4\u4f18<\/strong>\u2014\u2014160\u7cfb\u7edf\u8986\u76d6\u5076\u7528\u533a\uff0c\u907f\u514d\u4e3a\u5927\u7cfb\u7edf\u591a\u4ed8\u4e3b\u673a\u4e0e\u5b89\u88c5\u6210\u672c\uff1b<br>\n    2. <strong>\u65e5\u5e38\u66f4\u8282\u80fd<\/strong>\u2014\u2014\u5b50\u5973\u4e0d\u5728\u5bb6\u65f6\u4e09\u56db\u697c160\u7cfb\u7edf\u5b8c\u5168\u5173\u673a\uff0c\u4ec5\u8fd0\u884c\u4e00\u4e8c\u697c280\u7cfb\u7edf\uff1b<br>\n    3. <strong>\u7ef4\u62a4\u66f4\u7075\u6d3b<\/strong>\u2014\u2014\u4e24\u5957\u72ec\u7acb\u8fd0\u884c\u3001\u72ec\u7acb\u8ba1\u8d39\uff0c\u4efb\u4e00\u5957\u68c0\u4fee\u4e0d\u5f71\u54cd\u53e6\u4e00\u5957\uff1b<br>\n    4. <strong>\u4f53\u9a8c\u4e0d\u6253\u6298<\/strong>\u2014\u2014\u5e38\u5f00\u533a\u5168\u5f00\u65f6280\u7cfb\u7edf\u8fde\u63a5\u7387\u5408\u7406\u3001\u6548\u679c\u7a33\u5b9a\uff1b<br>\n    5. <strong>\u4e09\u8054\u4f9b\u5ef6\u5c55<\/strong>\u2014\u2014\u4e24\u5957\u7cfb\u7edf\u5747\u5ef6\u5c55\u4e09\u8054\u4f9b\uff0c\u5171\u4eab\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1+\u5a01\u4e50\u5faa\u73af\u6cf5+\u745e\u7f8eJSQ40-LX(T)\u70ed\u6c34\u5668\uff0c\u5168\u5c4b\u4e00\u5957\u70ed\u6c34\u903b\u8f91\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== S2\u00b7\u65b9\u6848\u8bca\u65ad ===== -->\n<section class=\"lm-section\" id=\"s2\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S2<\/span>\u65b9\u6848\u8bca\u65ad<\/div>\n\n  <p style=\"margin-bottom:16px;color:var(--lm-text2);\">\u9488\u5bf9\u674e\u5973\u58eb\"\u8212\u9002\u5065\u5eb7\u3001\u9664\u6e7f\u9664\u83cc\u3001\u4e09\u8054\u4f9b\u70ed\u6c34\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355\"\u7684\u6838\u5fc3\u8bc9\u6c42\uff0c\u4ee5\u4e0b\u4ece<strong style=\"color:var(--lm-gold2);\">\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u5ef6\u5c55\u4e09\u8054\u4f9b\uff09<\/strong>\u4e0e<strong style=\"color:var(--lm-gold2);\">\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\u4e8c\u8054\u4f9b\uff09<\/strong>\u5c55\u5f00\u5206\u7ef4\u5ea6\u8bca\u65ad\uff0c\u6309\"\u4f53\u9a8c \/ \u6280\u672f \/ \u8fd0\u7ef4\"\u4e09\u7c7b\u5207\u6362\u67e5\u770b\u3002<\/p>\n\n  <div class=\"lm-tabs-nav\">\n    <button class=\"lm-tab-btn lm-active\" data-tab=\"t1\">\u4f53\u9a8c\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t2\">\u6280\u672f\u7ef4\u5ea6<\/button>\n    <button class=\"lm-tab-btn\" data-tab=\"t3\">\u8fd0\u7ef4\u7ef4\u5ea6<\/button>\n  <\/div>\n\n  <div class=\"lm-tab-panel lm-active\" id=\"t1\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:16%;\">\u7ef4\u5ea6<\/th><th style=\"width:38%;\">\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u63a8\u8350\uff09<\/th><th style=\"width:38%;\">\u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:8%;\">\u7ed3\u8bba<\/th><\/tr>\n      <tr><td><strong>\u5236\u51b7\u4f53\u9a8c<\/strong><\/td><td>\u5236\u51b7\u5feb\uff0c\u51fa\u98ce7-12\u2103\uff0c\u9664\u6e7f\u6781\u5f3a\u3002\u4e09\u7ba1\u5236\u5185\u673a\u6807\u914d<strong style=\"color:var(--lm-gold2);\">\u4e0d\u964d\u6e29\u9664\u6e7f<\/strong>\uff0c\u6885\u96e8\u5b63\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/td><td>\u51fa\u98ce\u67d4\u548c15-20\u2103\uff0c\u4f46\u9664\u6e7f\u5f31\uff0c<strong>\u9700\u4f9d\u8d56\u5236\u51b7\u9664\u6e7f<\/strong>\uff0c\u6885\u96e8\u5b63\u4f53\u611f\u504f\u95f7<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n      <tr><td><strong>\u5236\u70ed\u4f53\u9a8c<\/strong><\/td><td>\u5730\u6696\u7531\u6c34\u6a21\u5757\u4f9b\u70ed\uff0c\u5ba4\u6e29\u5747\u5300\u3002\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a-25\u2103\u7a33\u5b9a\u8fd0\u884c<\/td><td>\u5730\u6696\u5747\u5300\u4f9b\u70ed\uff0c\u6c34\u7cfb\u7edf\u67d4\u548c\u4e0d\u5e72\u71e5\uff0c\u51fa\u6c34\u6e29\u5ea6\u53ef\u8c03\u8303\u56f4\u66f4\u5bbd<\/td><td>\u57fa\u672c\u6301\u5e73<\/td><\/tr>\n      <tr><td><strong>\u9664\u6e7f\u80fd\u529b<\/strong><\/td><td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u9664\u6e7f\u91cf175L\/\u5929\uff0c\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\/\u5730\u4e0b\u5ba4\u6781\u53cb\u597d<\/td><td>\u9664\u6e7f\u5f31\uff0c\u9700\u9760\u5236\u51b7\u9664\u6e7f\uff0c\u72ec\u7acb\u9664\u6e7f\u9700\u9009\u914d\uff08\u989d\u5916\u8d39\u7528\uff09<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n      <tr><td><strong>\u7a7a\u6c14\u51c0\u5316<\/strong><\/td><td>\u6807\u914d<strong style=\"color:var(--lm-gold2);\">PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/strong>\uff0cPM2.5\u53bb\u9664\u738799%\uff1b\u4e24\u7ba1\u5236\u51c0\u5316\u5185\u673a\u81ea\u5e26\u51c0\u5316<\/td><td>\u51c0\u5316\u80fd\u529b\u8f83\u5f31\uff0c\u540c\u7b49\u914d\u7f6e\u9700\u989d\u5916\u9009\u914d\u51c0\u5316\u914d\u4ef6<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t2\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:16%;\">\u7ef4\u5ea6<\/th><th style=\"width:38%;\">\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u63a8\u8350\uff09<\/th><th style=\"width:38%;\">\u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:8%;\">\u7ed3\u8bba<\/th><\/tr>\n      <tr><td><strong>\u7cfb\u7edf\u7c7b\u578b<\/strong><\/td><td><span class=\"lm-tag lm-tag-blue\">\u5929\u6c1f\u5730\u6c34<\/span><br>\u7a7a\u8c03\u4fa7\u6c1f\u76f4\u51b7\uff08\u4e00\u6b21\u6362\u70ed\uff09\uff0c\u5730\u6696\u4fa7\u70ed\u6c34<\/td><td><span class=\"lm-tag lm-tag-orange\">\u5929\u6c34\u5730\u6c34<\/span><br>\u7a7a\u8c03\u4e0e\u5730\u6696\u5747\u4e3a\u6c34\u7cfb\u7edf\uff08\u4e8c\u6b21\u6362\u70ed\uff09<\/td><td>-<\/td><\/tr>\n      <tr><td><strong>\u5b89\u88c5\u590d\u6742\u5ea6<\/strong><\/td><td><span class=\"lm-tag lm-tag-green\">\u6807\u51c6\u5316\u5b89\u88c5<\/span><br>\u7a7a\u8c03\u4fa7\u94dc\u7ba1\uff08\u6807\u51c6\u5316\u5de5\u827a\uff09\uff0c\u5730\u6696\u4fa7\u63a5\u7ba1\u7b80\u5355<\/td><td><span class=\"lm-tag lm-tag-red\">\u8981\u6c42\u6781\u9ad8<\/span><br>\u9700\u6c34\u529b\u5e73\u8861\u8bbe\u8ba1\uff0c\u4e0d\u5f53\u6613\u6f0f\u6c34\/\u7ed3\u9732\/\u6548\u679c\u5dee<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n      <tr><td><strong>\u8fde\u63a5\u7387\u9650\u5236<\/strong><\/td><td>\u6c1f\u7cfb\u7edf\u2264150%\uff0c\u672c\u6848280\u7cfb\u7edf\u7ea6119%\u3001160\u7cfb\u7edf\u7ea6124%\uff0c\u5747\u6b63\u5e38\u8303\u56f4<\/td><td>\u53ef\u8d85200%\uff0c\u5927\u6237\u578b\u81ea\u7531\u5ea6\u66f4\u9ad8<\/td><td>\u6c34\u5885\u9002\u7565\u4f18<\/td><\/tr>\n      <tr><td><strong>\u521d\u6295\u8d44<\/strong><\/td><td>\u542b\u7a7a\u8c03+\u5730\u6696\uff0c\u8bbe\u5907\u6210\u719f\uff0c\u4ef7\u683c\u900f\u660e<\/td><td>\u8bbe\u5907\u6210\u672c\u63a5\u8fd1\uff0c\u4f46\u5b89\u88c5\u8c03\u8bd5\u8d39\u7528\u66f4\u9ad8<\/td><td>\u5c0a\u777f\u7565\u4f18<\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tab-panel\" id=\"t3\">\n    <table class=\"lm-table\">\n      <tr><th style=\"width:16%;\">\u7ef4\u5ea6<\/th><th style=\"width:38%;\">\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u63a8\u8350\uff09<\/th><th style=\"width:38%;\">\u6c34\u5885\u9002\u4e8c\u8054\u4f9b<\/th><th style=\"width:8%;\">\u7ed3\u8bba<\/th><\/tr>\n      <tr><td><strong>\u81ea\u6e05\u6d01<\/strong><\/td><td>\u6807\u914d<strong style=\"color:var(--lm-gold2);\">\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/strong>\uff0c\u51cf\u5c11\u4eba\u5de5\u6e05\u6d17\u9891\u7387<\/td><td>\u6c34\u7cfb\u7edf\u65e0\u81ea\u6e05\u6d01\uff0c\u9700\u5b9a\u671f\u4eba\u5de5\u6e05\u6d17\u8fc7\u6ee4\u5668\/\u6362\u70ed\u5668<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n      <tr><td><strong>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/strong><\/td><td>\u6c1f\u7cfb\u7edf\u6210\u719f\u7a33\u5b9a\uff0c\u94dc\u7ba1\u5bc6\u5c01\u6027\u597d\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669<\/td><td>\u5168\u6c34\u7cfb\u7edf\u63a5\u5934\u591a\uff0c\u957f\u671f\u5b58\u5728\u6f0f\u6c34\u98ce\u9669\uff0c\u8c03\u6559\u96be<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n      <tr><td><strong>\u7ef4\u62a4\u7ef4\u4fee<\/strong><\/td><td><span class=\"lm-tag lm-tag-green\">\u7ef4\u62a4\u7b80\u5355<\/span><br>\u8fd0\u884c\u7a33\u5b9a\uff0c\u81ea\u6e05\u6d01\u51cf\u5c11\u6e05\u6d17\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef<\/td><td><span class=\"lm-tag lm-tag-orange\">\u7ef4\u62a4\u9700\u6c42\u9ad8<\/span><br>\u9700\u5b9a\u671f\u6e05\u6d17Y\u578b\u8fc7\u6ee4\u5668\u3001\u6392\u6c14\u9600\u3001\u8865\u6c34\u9600\uff0c\u6613\u7ed3\u57a2<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n      <tr><td><strong>20\u5e74\u8fd0\u7ef4\u603b\u6295\u5165<\/strong><\/td><td>\u6c1f\u673a\u7a33\u5b9a\u5c11\u6545\u969c\uff0c\u5e74\u7ef4\u4fdd\u4f4e\uff0c\u81ea\u6e05\u6d01\u7701\u6e05\u6d17\u5f00\u652f<\/td><td>\u9700\u5b9a\u671f\u6362\u8fc7\u6ee4\u5668\u3001\u6d17\u7ba1\u8def\uff0c\u7ef4\u4fdd\u9ad8\uff0c\u6f5c\u5728\u7ef4\u4fee\u98ce\u9669\u5927<\/td><td><span class=\"lm-tag lm-tag-green\">\u5c0a\u777f\u4f18<\/span><\/td><\/tr>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-highlight\" style=\"margin:20px 0;\">\n    <strong>\u7efc\u5408\u7ed3\u8bba\uff1a<\/strong>\u9488\u5bf9\u674e\u5973\u58eb\"\u8212\u9002\u5065\u5eb7\u3001\u9664\u6e7f\u9664\u83cc\u3001\u4e09\u8054\u4f9b\u70ed\u6c34\u3001\u7cfb\u7edf\u7a33\u5b9a\u3001\u7ef4\u62a4\u7b80\u5355\"\u7684\u6838\u5fc3\u8bc9\u6c42\uff0c<strong>\u63a8\u8350\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u5929\u6c1f\u5730\u6c34\uff09\u5206\u533a\u53cc\u7cfb\u7edf\u65b9\u6848\uff0c\u5ef6\u5c55\u4e09\u8054\u4f9b<\/strong>\uff1a<br>\n    1. <strong>\u529f\u80fd\u4f53\u9a8c\u4f73<\/strong>\u2014\u2014\u4e09\u7ba1\u5236\u5185\u673a\u72ec\u7acb\u4e0d\u964d\u6e29\u9664\u6e7f\uff08\u6210\u90fd\u6885\u96e8\u5b63\u521a\u9700\uff09+ PE\u51c0\u5316\u6807\u914d+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc\uff1b<br>\n    2. <strong>\u4e09\u8054\u4f9b\u70ed\u6c34<\/strong>\u2014\u2014\u5ef6\u5c55\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1+\u5a01\u4e50\u5faa\u73af\u6cf5+\u745e\u7f8eJSQ40-LX(T)\u70ed\u6c34\u5668\uff0c\u590f\u5b63\u70ed\u6cf5\u4f9b\u70ed\u6c34\u7701\u6c14\u8d39\uff0c\u51ac\u5b63\u70ed\u6c34\u5668\u8054\u52a8\u6c34\u7bb1\u4fdd\u969c\u53cc\u536b\u540c\u65f6\u4f7f\u7528\uff1b<br>\n    3. <strong>\u5206\u533a\u66f4\u8282\u80fd<\/strong>\u2014\u2014280\uff081-2F\u5e38\u5f00\uff09+160\uff083-4F\u5076\u7528\uff09\u53cc\u7cfb\u7edf\u72ec\u7acb\u542f\u505c\uff0c\u5b50\u5973\u4e0d\u5728\u5bb6\u65f6\u4e09\u56db\u697c\u5b8c\u5168\u5173\u673a\uff1b<br>\n    4. <strong>\u7cfb\u7edf\u7a33\u5b9a\u53ef\u9760<\/strong>\u2014\u2014\u6c1f\u7cfb\u7edf\u94dc\u7ba1\u6807\u51c6\u5316\u5b89\u88c5\uff0c\u65e0\u6f0f\u6c34\u98ce\u9669\uff1b<br>\n    5. <strong>\u7ef4\u62a4\u7b80\u5355<\/strong>\u2014\u2014\u81ea\u6e05\u6d01\u51cf\u5c11\u4eba\u5de5\u6e05\u6d17\uff0c\u5e74\u5ea6\u56de\u8bbf\u5373\u53ef\uff0c\u5404\u5185\u673a\u72ec\u7acb\u7ebf\u63a7\u5668\u64cd\u63a7\u7b80\u5355\u76f4\u63a5\u3002\n  <\/div>\n\n  <h3 id=\"s2-five\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5c0a\u777f\u5168\u6548 \u00b7 \u4e09\u8054\u4f9b\u7cfb\u7edf\u4f53\u9a8c\u89e3\u8bfb<\/h3>\n  <div class=\"lm-highlight\" style=\"margin-bottom:16px;\">\n    <strong>\u672c\u65b9\u6848\u4ee5\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\u4e3a\u57fa\u7840\u5ef6\u5c55\u4e09\u8054\u4f9b<\/strong>\uff0c\u901a\u8fc7\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u7a7a\u8c03 + \u745e\u7f8e\u6362\u70ed\u6c34\u7bb1\/\u70ed\u6c34\u5668 + \u5a01\u4e50\u5faa\u73af\u6cf5\uff0c\u5b9e\u73b0\"\u5236\u51b7 \u00b7 \u91c7\u6696 \u00b7 \u751f\u6d3b\u70ed\u6c34\"\u4e09\u8054\u4f9b\u2014\u2014\u8fd9\u6b63\u662f\u674e\u5973\u58eb\"\u8212\u9002\u5065\u5eb7 + \u4e09\u8054\u4f9b\u70ed\u6c34 + \u8282\u80fd\u7701\u6c14\"\u6838\u5fc3\u8bc9\u6c42\u7684\u5b8c\u6574\u843d\u5730\uff0c\u4e5f\u662f\u76f8\u8f83\u539f\u522b\u5885\u5176\u4ed6\u54c1\u724c\u7a7a\u8c03\u7684\u6839\u672c\u6027\u5347\u7ea7\u3002\n  <\/div>\n  <div class=\"lm-compare-grid\">\n    <div class=\"lm-compare-card\"><span class=\"lm-badge lm-badge-rec\">\u6052 \u6e29<\/span><h4>\u6e29\u5ea6\u6052\u5b9a \u00b7 \u65e0\u6b7b\u89d2<\/h4><p style=\"font-size:13px;color:var(--lm-text2);\">\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 + \u5929\u6c1f\u5730\u6c34\u5730\u6696\uff0c\u5206\u533a\u63a7\u6e29\uff0c\u5168\u5c4b\u6e29\u5ea6\u5747\u5300\uff0c\u907f\u514d\u539f\u7a7a\u8c03\"\u8d8a\u5439\u8d8a\u51b7\"\u7684\u8fc7\u51b7\u4e0d\u9002\u3002<\/p><\/div>\n    <div class=\"lm-compare-card\"><span class=\"lm-badge lm-badge-rec\">\u6052 \u6e7f<\/span><h4>\u6e7f\u5ea6\u6052\u5b9a \u00b7 \u4e0d\u964d\u6e29\u9664\u6e7f<\/h4><p style=\"font-size:13px;color:var(--lm-text2);\">\u72ec\u7acb\u4e0d\u964d\u6e29\u9664\u6e7f 175L\/\u5929\uff0c\u6885\u96e8\u5b63\u6e7f\u5ea6\u6052\u5b9a\u8212\u9002\uff0c\u4e0d\u518d\u9760\u5236\u51b7\u9664\u6e7f\u5e26\u6765\u7684\u8fc7\u51b7\u3002<\/p><\/div>\n    <div class=\"lm-compare-card\"><span class=\"lm-badge lm-badge-rec\">\u6052 \u9759<\/span><h4>\u9759\u97f3\u6052\u9759 \u00b7 \u226430dB<\/h4><p style=\"font-size:13px;color:var(--lm-text2);\">\u5185\u673a\u6700\u4f4e17dB\uff0c\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u6a21\u5f0f \u226430dB\uff0c\u5f7b\u5e95\u89e3\u51b3\u539f\u7a7a\u8c03\u566a\u97f3\u504f\u5927\u75db\u70b9\u3002<\/p><\/div>\n    <div class=\"lm-compare-card lm-recommend\"><span class=\"lm-badge lm-badge-rec\">\u4e09\u8054\u4f9b\u70ed\u6c34<\/span><h4>\u5236\u51b7\u00b7\u91c7\u6696\u00b7\u70ed\u6c34\u4e00\u4f53<\/h4><p style=\"font-size:13px;color:var(--lm-text2);\">\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1+\u5a01\u4e50\u5faa\u73af\u6cf5+\u745e\u7f8eJSQ40-LX(T)\u70ed\u6c34\u5668\uff0c\u590f\u5b63\u70ed\u6cf5\u4f9b\u70ed\u6c34\uff0c\u51ac\u5b63\u70ed\u6c34\u5668\u8054\u52a8\u6c34\u7bb1\uff0c\u53cc\u536b\u540c\u65f6\u4f7f\u7528\u96f6\u538b\u529b\u3002<\/p><\/div>\n    <div class=\"lm-compare-card lm-recommend\"><span class=\"lm-badge lm-badge-rec\">\u8282\u80fd\u7701\u6c14<\/span><h4>\u7a7a\u6c14\u80fd\u4f18\u5148 \u00b7 \u7701\u6c14\u8d39<\/h4><p style=\"font-size:13px;color:var(--lm-text2);\">\u5c0f\u533a\u6c14\u8d394\u5143+\/m\u00b3\uff0c\u5168\u5e74\u5927\u90e8\u5206\u65f6\u95f4\u7528\u7a7a\u6c14\u80fd\u70ed\u6cf5\u4f9b\u70ed\u6c34\uff08COP\u22653.0\uff09\uff0c\u4ec5\u51ac\u5b63\u91c7\u6696\u5b63\u542f\u7528\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u5927\u5e45\u964d\u4f4e\u71c3\u6c14\u8d39\u3002<\/p><\/div>\n    <div class=\"lm-compare-card\"><span class=\"lm-badge lm-badge-rec\">\u7b80\u5355\u64cd\u63a7<\/span><h4>\u72ec\u7acb\u7ebf\u63a7 \u00b7 \u5373\u5f00\u5373\u7528<\/h4><p style=\"font-size:13px;color:var(--lm-text2);\">\u5404\u5185\u673a\u914d\u72ec\u7acb\u7ebf\u63a7\u5668\uff0c\u64cd\u63a7\u7b80\u5355\u76f4\u63a5\uff0c\u8001\u4eba\u4e5f\u80fd\u8f7b\u677e\u4f7f\u7528\uff1b\u5a01\u4e50\u5faa\u73af\u6cf5\u5373\u5f00\u5373\u70ed\uff0c\u65e0\u9700\u7b49\u5f85\u51b7\u6c34\u6392\u7a7a\u3002<\/p><\/div>\n  <\/div>\n\n  <h3 id=\"s2-scene\" style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u9002\u7528\u60c5\u666f\u5bf9\u6bd4\u901f\u67e5<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u5ba2\u6237\u573a\u666f<\/th><th>\u63a8\u8350\u65b9\u6848<\/th><th>\u7406\u7531<\/th><\/tr>\n    <tr><td>\u5bf9\u9664\u6e7f\u6709\u521a\u9700\uff08\u6210\u90fd\u6885\u96e8\u5b63\/\u5730\u4e0b\u5ba4\uff09<\/td><td><span class=\"lm-tag lm-tag-blue\">\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/span><\/td><td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/td><\/tr>\n    <tr><td>\u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\uff0c\u6015\u51b7\u98ce\u76f4\u5439<\/td><td><span class=\"lm-tag lm-tag-orange\">\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09<\/span><\/td><td>\u51fa\u98ce15-20\u2103\u66f4\u67d4\u548c<\/td><\/tr>\n    <tr><td>\u9700\u8981\u81ea\u6e05\u6d01+\u7a7a\u6c14\u51c0\u5316<\/td><td><span class=\"lm-tag lm-tag-blue\">\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/span><\/td><td>\u6807\u914dPE\u51c0\u5316+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6740\u83cc<\/td><\/tr>\n    <tr><td>\u9700\u8981\u4e09\u8054\u4f9b\uff08\u5236\u51b7+\u91c7\u6696+\u70ed\u6c34\uff09<\/td><td><span class=\"lm-tag lm-tag-blue\">\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/span><\/td><td>\u6c34\u6a21\u5757\u53ef\u5ef6\u5c55\u6362\u70ed\u6c34\u7bb1\uff0c\u7a7a\u6c14\u80fd\u4f9b\u70ed\u6c34\u7701\u6c14\u8d39<\/td><\/tr>\n    <tr><td>\u8ffd\u6c42\u6781\u7b80\u7ef4\u62a4<\/td><td><span class=\"lm-tag lm-tag-blue\">\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/span><\/td><td>\u6c1f\u7cfb\u7edf\u7a33\u5b9a\uff0c\u81ea\u6e05\u6d01\u51cf\u5c11\u4eba\u5de5\u7ef4\u62a4<\/td><\/tr>\n    <tr><td>\u5927\u7a7a\u95f4\u65e0\u5185\u673a\u8fde\u63a5\u7387\u9650\u5236\u9700\u6c42<\/td><td><span class=\"lm-tag lm-tag-orange\">\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09<\/span><\/td><td>\u8fde\u63a5\u7387\u53ef\u8d85200%\uff0c\u7075\u6d3b\u6027\u5f3a<\/td><\/tr>\n    <tr><td>\u56db\u5c42\u522b\u5885\u00b7\u697c\u5c42\u4f7f\u7528\u9891\u7387\u5dee\u5f02\u5927<\/td><td><span class=\"lm-tag lm-tag-blue\">\u5c0a\u777f\u5168\u6548\u53cc\u7cfb\u7edf\u5206\u533a<\/span><\/td><td>\u5e38\u5f00\u533a280+\u5076\u7528\u533a160\uff0c\u72ec\u7acb\u542f\u505c\u66f4\u8282\u80fd<\/td><\/tr>\n  <\/table>\n<\/section>\n\n<!-- ===== S3\u00b7\u7cfb\u7edf\u8bbe\u8ba1 ===== -->\n<section class=\"lm-section\" id=\"s3\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S3<\/span>\u7cfb\u7edf\u8bbe\u8ba1<\/div>\n\n  <h3 id=\"s3-arch\" style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u67b6\u6784\u603b\u89c8 \u00b7 \u53cc\u7cfb\u7edf\u5206\u533a<\/h3>\n  <div class=\"lm-compare-grid\">\n    <div class=\"lm-compare-card lm-recommend\">\n      <span class=\"lm-badge lm-badge-rec\">\u7cfb\u7edf\u4e00 \u00b7 \u5e38\u5f00\u533a<\/span>\n      <h4>\u5c0a\u777f\u5168\u6548280 + \u6c34\u6a21\u5757280 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a\u4e00\u5c42 \u00b7 \u4e8c\u5c42\uff08\u7236\u6bcd\/\u8001\u4eba\u5168\u5929\u9ad8\u9891\u4f7f\u7528\uff09<\/p>\n      <ul>\n        <li>\u5c0a\u777f\u5168\u6548280\u5916\u673a\uff08RAS-280FSXPNY5Q\uff09<\/li>\n        <li>\u6c34\u6a21\u5757280\uff08RWMG-280FWXNZQ\uff09\u9a71\u52a8\u5730\u6696<\/li>\n        <li>\u4e09\u7ba1\u5236\u5185\u673a\u00d77 + \u53a8\u623f\u4e13\u7528\u00d71 + \u536b\u6d74\u4e13\u7528\u00d71\uff08\u4e00\u62d6\u4e5d\uff09<\/li>\n        <li>\u5404\u5185\u673a\u914d\u72ec\u7acb\u7ebf\u63a7\u5668\u64cd\u63a7<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"lm-compare-card lm-recommend\">\n      <span class=\"lm-badge lm-badge-rec\">\u7cfb\u7edf\u4e8c \u00b7 \u5076\u7528\u533a<\/span>\n      <h4>\u5c0a\u777f\u5168\u6548160 + \u6c34\u6a21\u5757160 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b<\/h4>\n      <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a\u4e09\u5c42 \u00b7 \u56db\u5c42\uff08\u5b50\u5973\u5468\u672b\u56de\u5bb6\u624d\u7528\uff09<\/p>\n      <ul>\n        <li>\u5c0a\u777f\u5168\u6548160\u5916\u673a\uff08RAS-160FSXPNY5Q\uff09<\/li>\n        <li>\u6c34\u6a21\u5757160\uff08RWMG-160FWXNZQ\uff09\u9a71\u52a8\u5730\u6696<\/li>\n        <li>\u4e09\u7ba1\u5236\u5185\u673a\u00d73 + \u4e8c\u7ba1\u5236\u51c0\u5316\u5185\u673a\u00d72\uff08\u4e00\u62d6\u4e94\uff09<\/li>\n        <li>\u5404\u5185\u673a\u914d\u72ec\u7acb\u7ebf\u63a7\u5668\u64cd\u63a7<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf \u00b7 \u5236\u51b7+\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53<\/h3>\n  <div class=\"lm-compare-card lm-recommend\" style=\"max-width:100%;\">\n    <span class=\"lm-badge lm-badge-rec\">\u4e09\u8054\u4f9b\u5ef6\u5c55\u7cfb\u7edf<\/span>\n    <h4>\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1 + \u5a01\u4e50\u5faa\u73af\u6cf5 + \u745e\u7f8eJSQ40-LX(T)\u70ed\u6c34\u5668<\/h4>\n    <p style=\"font-size:13px;color:var(--lm-text2);margin:8px 0;\">\u9002\u7528\uff1a\u5168\u5c4b\u751f\u6d3b\u70ed\u6c34\u4f9b\u5e94\uff08\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u4f7f\u7528\uff09<\/p>\n    <table class=\"lm-table\" style=\"margin:12px 0;\">\n      <tr><th>\u5b63\u8282<\/th><th>\u70ed\u6c34\u70ed\u6e90<\/th><th>\u5de5\u4f5c\u903b\u8f91<\/th><th>\u8282\u80fd\u8981\u70b9<\/th><\/tr>\n      <tr><td><strong>\u590f\u5b63\uff08\u5236\u51b7\u5b63\uff09<\/strong><\/td><td>\u70ed\u6cf5\u7a7a\u6c14\u80fd<\/td><td>\u7a7a\u8c03\u5236\u51b7\u8fd0\u884c\u540c\u65f6\uff0c\u70ed\u6cf5\u52a0\u70ed150L\u6362\u70ed\u6c34\u7bb1\u4f9b\u751f\u6d3b\u70ed\u6c34<\/td><td>COP\u22653.0\uff0c\u51e0\u4e4e\u96f6\u6c14\u8d39\uff0c\u71c3\u6c14\u70ed\u6c34\u5668\u4e0d\u5f00\u673a<\/td><\/tr>\n      <tr><td><strong>\u8fc7\u6e21\u5b63\uff08\u6625\u79cb\uff09<\/strong><\/td><td>\u70ed\u6cf5\u7a7a\u6c14\u80fd<\/td><td>\u70ed\u6cf5\u72ec\u7acb\u8fd0\u884c\u52a0\u70ed\u6362\u70ed\u6c34\u7bb1\uff0c\u65e0\u9700\u542f\u52a8\u7a7a\u8c03\/\u5730\u6696<\/td><td>\u7a7a\u6c14\u80fd\u9ad8\u80fd\u6548\u6bd4\uff0c\u71c3\u6c14\u70ed\u6c34\u5668\u4e0d\u5f00\u673a<\/td><\/tr>\n      <tr><td><strong>\u51ac\u5b63\uff08\u91c7\u6696\u5b63\uff09<\/strong><\/td><td>\u71c3\u6c14\u70ed\u6c34\u5668+\u6362\u70ed\u6c34\u7bb1\u8054\u52a8<\/td><td>\u70ed\u6cf5\u4f18\u5148\u9a71\u52a8\u5730\u6696\uff0c\u745e\u7f8eJSQ40-LX(T) 20L\u70ed\u6c34\u5668\u8054\u52a8150L\u6362\u70ed\u6c34\u7bb1\u4f9b\u751f\u6d3b\u70ed\u6c34<\/td><td>\u70ed\u6c34\u5668\u6301\u7eed\u52a0\u70ed+\u6c34\u7bb1\u50a8\u80fd\u7f13\u51b2\uff0c\u53cc\u536b\u540c\u65f6\u6dcb\u6d74\u4e0d\u4e2d\u65ad<\/td><\/tr>\n    <\/table>\n    <ul>\n      <li>\u7f8e\u56fd\u745e\u7f8e150\u5347\u6362\u70ed\u6c34\u7bb1\uff1a\u5bb9\u79ef\u5f0f\u50a8\u80fd\u7f13\u51b2\uff0c\u70ed\u6cf5\/\u71c3\u6c14\u70ed\u6c34\u5668\u5747\u53ef\u52a0\u70ed\uff0c\u4fdd\u969c\u8fde\u7eed\u7a33\u5b9a\u4f9b\u6c34<\/li>\n      <li>\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5\uff1a\u70ed\u6c34\u7ba1\u8def\u56de\u6c34\u5faa\u73af\uff0c\u5373\u5f00\u5373\u70ed\u96f6\u7b49\u5f85\uff0c\u56db\u5c42\u522b\u5885\u957f\u7ba1\u8def\u5fc5\u5907<\/li>\n      <li>\u7f8e\u56fd\u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\uff1a20L\/min\u5927\u5bb9\u91cf\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u51ac\u5b63\u91c7\u6696\u5b63\u751f\u6d3b\u70ed\u6c34\u4fdd\u969c\u70ed\u6e90<\/li>\n      <li>\u5ba2\u6237\u5c0f\u533a\u5929\u7136\u6c144\u5143+\/m\u00b3\uff0c\u5168\u5e74\u5927\u90e8\u5206\u65f6\u95f4\u7528\u7a7a\u6c14\u80fd\u4f9b\u70ed\u6c34\uff0c\u5927\u5e45\u964d\u4f4e\u71c3\u6c14\u8d39\u7528<\/li>\n    <\/ul>\n  <\/div>\n\n  <div class=\"lm-highlight-blue\" style=\"margin:16px 0;\">\n    <strong>\u5206\u533a\u903b\u8f91\uff1a<\/strong>\u4e00\u4e8c\u697c\u4e3a\u7236\u6bcd\/\u8001\u4eba\u5e38\u5f00\u533a\u57df\uff0c\u5168\u5929\u9ad8\u9891\u4f7f\u7528\uff0c\u914d\u7f6e\u5c0a\u777f\u5168\u6548280\uff0828kW\uff09\u4e00\u62d6\u4e5d\u4fdd\u8bc1\u5168\u5f00\u4e0d\u964d\u9891\uff1b\u4e09\u56db\u697c\u4e3a\u5b50\u5973\u5468\u672b\u56de\u5bb6\u533a\u57df\uff0c\u4f7f\u7528\u9891\u7387\u4f4e\uff0c\u914d\u7f6e\u5c0a\u777f\u5168\u6548160\uff0816kW\uff09\u4e00\u62d6\u4e94\u65e2\u6ee1\u8db3\u9700\u6c42\u53c8\u663e\u8457\u964d\u4f4e\u521d\u6295\u8d44\u3002\u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\u3001\u72ec\u7acb\u8ba1\u8d39\uff0c\u5b50\u5973\u4e0d\u5728\u5bb6\u65f6\u4e09\u56db\u697c160\u7cfb\u7edf\u53ef\u5b8c\u5168\u5173\u673a\uff0c\u907f\u514d\u5927\u7cfb\u7edf\u4f4e\u9891\u7a7a\u8017\u3002\n  <\/div>\n\n  <h3 id=\"s3-u1\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u4e00\uff081F-2F \u5e38\u5f00\u533a\uff09\u00b7 280\u4e00\u62d6\u4e5d \u5185\u673a\u660e\u7ec6<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u5185\u673a\u7c7b\u578b<\/th><\/tr>\n    <tr><td>1F<\/td><td>\u5ba2\u9910\u5385<\/td><td>96 \u33a1<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>7.1kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>1F<\/td><td>\u5ba2\u9910\u5385<\/td><td>\u2014<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>5.6kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>1F<\/td><td>\u4e2d\u53a8<\/td><td>7.3 \u33a1<\/td><td>RCIS-22FSCN1QD<\/td><td>2.2kW<\/td><td>\u53a8\u623f\u4e13\u7528\u7a7a\u8c03<\/td><\/tr>\n    <tr><td>1F<\/td><td>\u5165\u6237\/\u95e8\u5385<\/td><td>31 \u33a1<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>3.6kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>1F<\/td><td>\u8001\u4eba\u623f<\/td><td>13 \u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u4e3b\u5367\u5ba4<\/td><td>26 \u33a1<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4.0kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u4e3b\u536b<\/td><td>9 \u33a1<\/td><td>RCIS-25FSWNQD<\/td><td>2.5kW<\/td><td>\u536b\u6d74\u4e13\u7528\u7a7a\u8c03<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u4e66\u623f<\/td><td>21 \u33a1<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>3.2kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>2F<\/td><td>\u8336\u5ba4<\/td><td>17 \u33a1<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>2.8kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\" style=\"text-align:left;\">\n      \u5916\u673a\uff1a\u5c0a\u777f\u5168\u6548 RAS-280FSXPNY5Q\uff0828.0kW\uff09\uff5c9\u53f0\u5185\u673a\u603b\u51b7\u91cf\uff1a33.2kW \u2192 \u8fde\u63a5\u7387\u7ea6119%\uff08\u5408\u7406\u8303\u56f4\uff09\uff5c\u6c34\u6a21\u5757\uff1aRWMG-280FWXNZQ\uff5c\u5404\u5185\u673a\u72ec\u7acb\u7ebf\u63a7\u5668\u64cd\u63a7\n    <\/td><\/tr>\n  <\/table>\n\n  <h3 id=\"s3-u2\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u4e8c\uff083F-4F \u5b50\u5973\u56de\u5bb6\u533a\uff09\u00b7 160\u4e00\u62d6\u4e94 \u5185\u673a\u660e\u7ec6<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><th>\u5185\u673a\u7c7b\u578b<\/th><\/tr>\n    <tr><td>3F<\/td><td>\u513f\u7ae5\u623f<\/td><td>32 \u33a1<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>4.5kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>3F<\/td><td>\u7535\u7ade\u623f<\/td><td>17 \u33a1<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>2.8kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>3F<\/td><td>\u8d77\u5c45\u5ba4<\/td><td>21 \u33a1<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>3.2kW<\/td><td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u50a8\u85cf\u5ba4<\/td><td>13 \u33a1<\/td><td>RPIZ-22FSVNZ1QD\/PC<\/td><td>2.2kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr><td>4F<\/td><td>\u591a\u529f\u80fd\u5ba4<\/td><td>36 \u33a1<\/td><td>RPIZ-71FSVNZ1QD\/PC<\/td><td>7.1kW<\/td><td>\u4e8c\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\" style=\"text-align:left;\">\n      \u5916\u673a\uff1a\u5c0a\u777f\u5168\u6548 RAS-160FSXPNY5Q\uff0816.0kW\uff09\uff5c5\u53f0\u5185\u673a\u603b\u51b7\u91cf\uff1a19.8kW \u2192 \u8fde\u63a5\u7387\u7ea6124%\uff08\u5408\u7406\u8303\u56f4\uff09\uff5c\u6c34\u6a21\u5757\uff1aRWMG-160FWXNZQ\uff5c\u5404\u5185\u673a\u72ec\u7acb\u7ebf\u63a7\u5668\u64cd\u63a7\uff5c\u50a8\u85cf\u5ba413\u33a1\u4e0d\u914d\u7f6e\u5730\u6696\n    <\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight-green\" style=\"margin:16px 0;\">\n    <strong>\u8bbe\u8ba1\u539f\u5219\uff1a<\/strong>\u6309GEO\u4e94\u6b65\u6cd5\u89c4\u8303\u8bbe\u8ba1\uff0c\u4e25\u683c\u9075\u5faaGB 50736-2012\u5236\u51b7\u8d1f\u8377\u6807\u51c6\uff08\u522b\u5885\u7c7b80-120W\/\u33a1\uff09\uff0c\u907f\u514d\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u3002\u4e24\u5957\u7cfb\u7edf\u8fde\u63a5\u7387\u5206\u522b\u63a7\u5236\u5728119%\u4e0e124%\uff0c\u65e2\u4fdd\u8bc1\u5168\u5f00\u65f6\u6548\u679c\u4e0d\u6253\u6298\uff0c\u4e5f\u907f\u514d\u5355\u5f00\u623f\u95f4\u9891\u7e41\u542f\u505c\u3002\n  <\/div>\n\n  <h3 id=\"s3-floor\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5730\u6696\u7cfb\u7edf \u00b7 \u5168\u5c4b370\u33a1\uff08\u50a8\u85cf\u5ba4\u9664\u5916\uff09<\/h3>\n  <div class=\"lm-info-grid\">\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u5730\u6696\u603b\u9762\u79ef<\/div><div class=\"lm-value\">370 \u33a1<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u8986\u76d6\u533a\u57df<\/div><div class=\"lm-value\">1F-4F\u5e38\u6d3b\u52a8\u533a<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u4e0d\u5730\u6696\u533a\u57df<\/div><div class=\"lm-value\">\u56db\u5c42\u50a8\u85cf\u5ba413\u33a1<\/div><\/div>\n    <div class=\"lm-info-item\"><div class=\"lm-label\">\u70ed\u6e90<\/div><div class=\"lm-value\">\u4e24\u5957\u6c34\u6a21\u5757<\/div><\/div>\n  <\/div>\n  <div class=\"lm-highlight\" style=\"margin:12px 0;\">\n    <strong>\u5730\u6696\u8bf4\u660e\uff1a<\/strong>\u4e00\u5c42\u81f3\u4e09\u5c42\u5168\u90e8\u533a\u57df\u53ca\u56db\u5c42\u591a\u529f\u80fd\u5ba4\u94fa\u8bbe\u5730\u6696\uff0c\u56db\u5c42\u50a8\u85cf\u5ba4\u4ee5\u50a8\u7269\u4e3a\u4e3b\u3001\u65e0\u957f\u65f6\u95f4\u505c\u7559\u9700\u6c42\uff0c\u6545\u4e0d\u914d\u7f6e\u5730\u6696\uff08\u907f\u514d\u95f2\u7f6e\u80fd\u8017\uff09\uff1b\u5168\u5c4b\u5730\u6696\u7531\u5c0a\u777f\u5168\u6548\u4e24\u5957\u6c34\u6a21\u5757\u7a7a\u6c14\u80fd\u9a71\u52a8\uff0cCOP\u22653.0\uff0c\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u770130%\u4ee5\u4e0a\u3002\u4e24\u5957\u6c34\u6a21\u5757\u540c\u65f6\u5ef6\u5c55\u4e09\u8054\u4f9b\uff0c\u590f\u5b63\/\u8fc7\u6e21\u5b63\u5229\u7528\u7a7a\u6c14\u80fd\u52a0\u70ed\u6362\u70ed\u6c34\u7bb1\u4f9b\u751f\u6d3b\u70ed\u6c34\uff0c\u8fdb\u4e00\u6b65\u964d\u4f4e\u71c3\u6c14\u8d39\u7528\u3002\n  <\/div>\n\n  <div class=\"lm-prod-showcase\">\n    <div class=\"lm-prod-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" alt=\"VAM\u5c0a\u777f\u5168\u6548II\">\n      <div class=\"lm-pc-body\">\n        <div class=\"lm-pc-title\">\u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548\u2161<\/div>\n        <div class=\"lm-pc-desc\">\u884c\u4e1a\u9996\u6b3e\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 \u00b7 175L\/\u5929\u9664\u6e7f\u91cf \u00b7 \u5168\u98ce\u8def\u51c0\u5316\u8231 \u00b7 17dB\u6781\u81f4\u9759\u97f3\uff08\u5367\u5ba4\u591c\u95f4\u9759\u97f3\u6a21\u5f0f\u226430dB\uff09 \u00b7 \u6c34\u6a21\u5757\u5ef6\u5c55\u4e09\u8054\u4f9b<\/div>\n        <a class=\"lm-pc-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\">\u67e5\u770b\u5c0a\u777f\u5168\u6548\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n    <div class=\"lm-prod-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/zr-quanxiao-02.jpg\" alt=\"\u745e\u7f8e\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\">\n      <div class=\"lm-pc-body\">\n        <div class=\"lm-pc-title\">\u7f8e\u56fd\u745e\u7f8e \u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf<\/div>\n        <div class=\"lm-pc-desc\">\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1 + \u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5 + \u745e\u7f8eJSQ40-LX(T) 20L\u71c3\u6c14\u70ed\u6c34\u5668 \u00b7 \u590f\u5b63\u70ed\u6cf5\u4f9b\u70ed\u6c34\u7701\u6c14\u8d39 \u00b7 \u51ac\u5b63\u70ed\u6c34\u5668\u8054\u52a8\u6c34\u7bb1\u4fdd\u969c\u53cc\u536b\u540c\u65f6\u4f7f\u7528 \u00b7 \u5373\u5f00\u5373\u70ed\u96f6\u7b49\u5f85<\/div>\n        <a class=\"lm-pc-link\" href=\"https:\/\/longmai-nt.com\/?page_id=662\" target=\"_blank\">\u67e5\u770b\u4ef7\u683c\u5e93\u8be6\u60c5 \u2192<\/a>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <h3 id=\"s3-craft\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cbe\u5de5\u516d\u6b65\u6cd5 + 2 \u6807\u51c6\u5316\u65bd\u5de5<\/h3>\n  <div class=\"lm-step-flow\">\n    <span class=\"lm-step\">01 \u73b0\u573a\u52d8\u6d4b<\/span>\n    <span class=\"lm-step\">02 \u7cfb\u7edf\u8bbe\u8ba1<\/span>\n    <span class=\"lm-step\">03 \u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/span>\n    <span class=\"lm-step\">04 \u7cfb\u7edf\u5b89\u88c5<\/span>\n    <span class=\"lm-step\">05 \u7cfb\u7edf\u8c03\u8bd5<\/span>\n    <span class=\"lm-step\">06 \u7ae3\u5de5\u9a8c\u6536<\/span>\n    <span class=\"lm-step\">+1 \u4ea4\u4ed8\u6559\u5b66<\/span>\n    <span class=\"lm-step\">+2 \u552e\u540e\u4fdd\u969c<\/span>\n  <\/div>\n\n  <div class=\"lm-carousel\" id=\"lmCraftCarousel\">\n    <div class=\"lm-carousel-track\">\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">01<\/span><div class=\"lm-cs-title\">\u73b0\u573a\u52d8\u6d4b<\/div><\/div>\n        <div class=\"lm-cs-body\">\u8bbe\u8ba1\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u6237\u578b\u7ed3\u6784\u3001\u5c42\u9ad8\u3001\u5916\u673a\u4f4d\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\uff0c\u7cbe\u786e\u6d4b\u91cf\u5404\u623f\u95f4\u9762\u79ef\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u52d8\u6d4b\u62a5\u544a + \u73b0\u573a\u7167\u7247\u5b58\u6863<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/hlxglyt-fls-xckc-03.jpg\" alt=\"\u73b0\u573a\u52d8\u6d4b\u5b9e\u666f\"><figcaption class=\"lm-cap\">\u73b0\u573a\u52d8\u6d4b<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">02<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u8bbe\u8ba1<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6839\u636e\u52d8\u6d4b\u6570\u636e\u8ba1\u7b97\u70ed\u8d1f\u8377\uff0c\u7ed8\u5236\u76d8\u7ba1\u5e03\u7f6e\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u56fe\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u8bbe\u8ba1\u56fe\u7eb8\u7ecf\u5ba2\u6237\u786e\u8ba4\u540e\u65bd\u5de5<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-vamzrftsllgxtylt-1.jpg\" alt=\"\u7cfb\u7edf\u8bbe\u8ba1\u793a\u610f\u56fe\"><figcaption class=\"lm-cap\">\u7cfb\u7edf\u8bbe\u8ba1\u65b9\u6848<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">03<\/span><div class=\"lm-cs-title\">\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6240\u6709\u7ba1\u6750\u3001\u4fdd\u6e29\u6750\u6599\u4e0e\u5ba2\u6237\u5171\u540c\u6838\u9a8c\u54c1\u724c\u578b\u53f7\u89c4\u683c\uff0c\u94dc\u7ba1\u58c1\u539a\u9010\u6839\u6d4b\u91cf\u7559\u75d5\uff0c\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u5373\u9a8c\u6536\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\uff0c\u7559\u5b58\u6750\u6599\u7167\u7247<\/div>\n        <div class=\"lm-cs-imgs\">\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u5185\u5916\u673a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\"><figcaption class=\"lm-cap\">\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u94dc\u7ba1\u58c1\u539a\"><figcaption class=\"lm-cap\">\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c<\/figcaption><\/figure>\n        <\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">04<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u5b89\u88c5<\/div><\/div>\n        <div class=\"lm-cs-body\">\u94dc\u7ba1\u710a\u63a5\uff08\u5145\u6c2e\u4fdd\u62a4\uff09\u3001\u5206\u6b67\u7ba1\u5b89\u88c5\u3001\u4fdd\u6e29\u5305\u88f9\u3001\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u3001\u6253\u538b\u6d4b\u8bd5\u3002\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\u56fa\u5b9a\uff0c\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\u6392\u5e03\u5e76\u8bbe\u6392\u6c14\u5b54\u3001\u6807\u51c6\u63a5\u5165\u5730\u6f0f\uff0c\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\u3001\u6c2e\u6c14\u4fdd\u538b\u5168\u7a0b\u7559\u75d5\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u6253\u538b 0.6-0.8MPa\uff0c\u7a33\u538b\u22651h\uff0c\u538b\u964d\u22640.05MPa<\/div>\n        <div class=\"lm-cs-imgs\">\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\" alt=\"\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\"><figcaption class=\"lm-cap\">\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\"><figcaption class=\"lm-cap\">\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xhmpqk.jpg\" alt=\"\u51b7\u51dd\u6c34\u7ba1\u5c0f\u7ea2\u5e3d\u6392\u6c14\u5b54\"><figcaption class=\"lm-cap\">\u6392\u6c14\u5b54<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-frdl.jpg\" alt=\"\u51b7\u51dd\u6c34\u7ba1\u6807\u51c6\u653e\u5165\u5730\u6f0f\"><figcaption class=\"lm-cap\">\u6392\u6c34\u6807\u51c6\u5165\u5730\u6f0f<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" alt=\"\u6c2e\u6c14\u4fdd\u538b\u8868\"><figcaption class=\"lm-cap\">\u6c2e\u6c14\u4fdd\u538b\u8868<\/figcaption><\/figure>\n          <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\"><figcaption class=\"lm-cap\">\u62bd\u771f\u7a7a\u4fdd\u538b<\/figcaption><\/figure>\n        <\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">05<\/span><div class=\"lm-cs-title\">\u7cfb\u7edf\u8c03\u8bd5<\/div><\/div>\n        <div class=\"lm-cs-body\">\u6ce8\u6c34\u6392\u6c14\u3001\u8054\u52a8\u903b\u8f91\u9a8c\u8bc1\u3001\u5404\u56de\u8def\u6d41\u91cf\u5747\u5300\u6027\u8c03\u8bd5\uff0c\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\u8054\u52a8\u8c03\u8bd5\uff08\u70ed\u6cf5-\u6362\u70ed\u6c34\u7bb1-\u70ed\u6c34\u5668-\u5faa\u73af\u6cf5\u8054\u52a8\u903b\u8f91\u9a8c\u8bc1\uff09\uff0c\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\u786e\u4fdd\u8fd0\u884c\u53c2\u6570\u8fbe\u6807\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5404\u623f\u95f4\u6e29\u5dee\u22642\u2103<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\"><figcaption class=\"lm-cap\">\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">06<\/span><div class=\"lm-cs-title\">\u7ae3\u5de5\u9a8c\u6536<\/div><\/div>\n        <div class=\"lm-cs-body\">\u9690\u853d\u5de5\u7a0b\u5f71\u50cf\u5f52\u6863\uff0c\u9010\u9879\u9a8c\u6536\u7b7e\u5b57\uff0c\u4ea4\u4ed8\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u3002\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\u4f5c\u4e3a\u9a8c\u6536\u51ed\u8bc1\u5b58\u6863\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5f71\u50cf\u6863\u6848 + \u9a8c\u6536\u8bb0\u5f55 + \u4f7f\u7528\u624b\u518c<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\"><figcaption class=\"lm-cap\">\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">+1<\/span><div class=\"lm-cs-title\">\u4ea4\u4ed8\u6559\u5b66<\/div><\/div>\n        <div class=\"lm-cs-body\">\u4e00\u5bf9\u4e00\u73b0\u573a\u8bbe\u5907\u6559\u5b66\uff0c\u6559\u4f1a\u6e29\u63a7\u5668\u4f7f\u7528\u3001\u6a21\u5f0f\u5207\u6362\u3001\u7d27\u6025\u64cd\u4f5c\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u5ba2\u6237\u80fd\u72ec\u7acb\u64cd\u4f5c<\/div>\n        <div class=\"lm-cs-imgs\"><figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\" alt=\"\u73b0\u573a\u8bbe\u5907\u6559\u5b66\"><figcaption class=\"lm-cap\">\u73b0\u573a\u8bbe\u5907\u6559\u5b66<\/figcaption><\/figure><\/div>\n      <\/div>\n      <div class=\"lm-slide\">\n        <div class=\"lm-cs-head\"><span class=\"lm-cs-num\">+2<\/span><div class=\"lm-cs-title\">\u552e\u540e\u4fdd\u969c<\/div><\/div>\n        <div class=\"lm-cs-body\">\u65e5\u7acb\u5168\u5957\u8bbe\u59076\u5e74\u8d28\u4fdd\uff08\u54c1\u724c\u6708\u6d3b\u52a8\u5ef6\u4fdd\u81f310\u5e74\uff09\uff1b\u4f1f\u661f\u7ba1\u8def\u5382\u5bb6+\u4fdd\u9669+\u9f99\u8109\u4e09\u65b9\u8054\u4fdd50\u5e74\uff1b\u9f99\u7684\u5341\u5e74\u80fd\u6e90\u4fdd\u969c\u670d\u52a1\u5168\u7a0b\u62a4\u822a\u3002<\/div>\n        <div class=\"lm-cs-std\"><b>\u9a8c\u6536\u6807\u51c6\uff1a<\/b>\u9f99\u7684\u5341\u5e74\u80fd\u6e90\u4fdd\u969c\u670d\u52a1\u843d\u5730<\/div>\n      <\/div>\n    <\/div>\n    <button class=\"lm-car-arrow lm-prev\" onclick=\"lmCarGo(lmCarCur-1)\" aria-label=\"\u4e0a\u4e00\u6b65\">\u2039<\/button>\n    <button class=\"lm-car-arrow lm-next\" onclick=\"lmCarGo(lmCarCur+1)\" aria-label=\"\u4e0b\u4e00\u6b65\">\u203a<\/button>\n    <div class=\"lm-car-dots\" id=\"lmCarDots\"><\/div>\n  <\/div>\n\n  <h3 style=\"margin:20px 0 12px;color:var(--lm-gold2);\">\u9690\u853d\u5de5\u7a0b\u53ef\u89c6\u5316<\/h3>\n  <div class=\"lm-highlight-blue\">\u6bcf\u4e2a\u65bd\u5de5\u73af\u8282\u62cd\u7167\u5b58\u6863\uff0c\u5f62\u6210\u5b8c\u6574\u7684\u65bd\u5de5\u5f71\u50cf\u6863\u6848\u3002\u674e\u5973\u58eb\u53ef\u901a\u8fc7\u624b\u673a\u968f\u65f6\u67e5\u770b\u5de5\u5730\u8fdb\u5ea6\u548c\u9690\u853d\u5de5\u7a0b\u5b9e\u51b5\uff0c\u505a\u5230\"\u770b\u4e0d\u89c1\u7684\u5730\u65b9\u4e5f\u653e\u5fc3\"\u3002<\/div>\n<\/section>\n\n<!-- ===== S4\u00b7\u900f\u660e\u62a5\u4ef7 ===== -->\n<section class=\"lm-section\" id=\"s4\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S4<\/span>\u900f\u660e\u62a5\u4ef7<\/div>\n\n  <div class=\"lm-highlight\" style=\"margin-bottom:16px;\">\n    <strong>\u4ef7\u683c\u6765\u6e90\u4e0e\u6298\u6263\u89c4\u5219\uff1a<\/strong>\u6307\u4ee40\uff08\u5de5\u4f5c\u57fa\u7ebf V6.2\uff09+ \u6307\u4ee42 \u4ef7\u683c\u5e93 V5.0 \uff5c \u5c0a\u777f\u5168\u6548\u5ba4\u5916\u673a\u53ca\u5168\u90e8\u5185\u673a\uff08\u4e09\u7ba1\u5236\/\u4e8c\u7ba1\u5236\/\u53a8\u623f\u4e13\u7528\/\u536b\u6d74\u4e13\u7528\uff09\u4eab <strong>8\u6298<\/strong> \uff5c \u6c34\u6a21\u5757\u4e3a<strong>\u4e0d\u6253\u6298<\/strong>\u4ea7\u54c1\uff08\u4ee5\u9762\u4ef7\u8ba1\uff09\uff5c \u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\u5355\u4ef7<strong>5,999\u5143<\/strong>\uff08\u4e0d\u6253\u6298\uff09\uff5c \u5a01\u4e50\u5faa\u73af\u6cf5<strong>1,200\u5143<\/strong>\uff08\u4e0d\u6253\u6298\uff09\uff5c \u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1<strong>2,600\u5143<\/strong>\uff08\u4e0d\u6253\u6298\uff09+ \u5b89\u88c5\u8d39<strong>1,200\u5143<\/strong> \uff5c \u5b89\u88c5\u8d39\uff1a\u4e09\u7ba1\u5236\u5185\u673a 2,100\u5143\/\u53f0\u3001\u4e8c\u7ba1\u5236\u5185\u673a 1,800\u5143\/\u53f0\u3001\u53a8\u623f\/\u536b\u6d74\u4e13\u7528\u5185\u673a 1,600\u5143\/\u53f0\u3001\u5916\u673a 600\u5143\u3001\u6c34\u6a21\u5757 625\u5143\uff08\u5747\u4e0d\u6253\u6298\uff09\uff1b\u70ed\u6c34\u5668\u53ca\u5faa\u73af\u6cf5\u5b89\u88c5\u8d39\u5df2\u542b\u3002\n  <\/div>\n\n  <h3 id=\"s4-s1\" style=\"margin-bottom:12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u4e00\uff1a\u5c0a\u777f\u5168\u6548280 + \u6c34\u6a21\u5757280 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff081F-2F \u5e38\u5f00\u533a\uff09<\/h3>\n\n  <h4 style=\"margin:12px 0 6px;color:var(--lm-gold2);\">1. \u5ba4\u5916\u673a + \u6c34\u6a21\u5757<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u6263<\/th><th>\u6298\u540e\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u5c0a\u777f\u5168\u6548\u5ba4\u5916\u673a<\/td><td>RAS-280FSXPNY5Q<\/td><td>34,788<\/td><td>8\u6298<\/td><td>27,830<\/td><td>600<\/td><td>28,430<\/td><\/tr>\n    <tr><td>2<\/td><td>\u6c34\u6a21\u5757280<\/td><td>RWMG-280FWXNZQ<\/td><td>11,250<\/td><td>\u4e0d\u6253\u6298<\/td><td>11,250<\/td><td>625<\/td><td>11,875<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"7\">\u4e3b\u673a\u5c0f\u8ba1<\/td><td>40,305<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">2. \u5ba4\u5185\u673a\uff08\u4e00\u62d6\u4e5d\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u533a\u57df<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>8\u6298<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>3<\/td><td>1F\u5ba2\u9910\u5385 71\u4e09\u7ba1\u5236<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>5,825<\/td><td>4,660<\/td><td>2,100<\/td><td>6,760<\/td><\/tr>\n    <tr><td>4<\/td><td>1F\u5ba2\u9910\u5385 56\u4e09\u7ba1\u5236<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>5,663<\/td><td>4,530<\/td><td>2,100<\/td><td>6,630<\/td><\/tr>\n    <tr><td>5<\/td><td>1F\u4e2d\u53a8 \u53a8\u623f\u4e13\u7528<\/td><td>RCIS-22FSCN1QD<\/td><td>6,175<\/td><td>4,940<\/td><td>1,600<\/td><td>6,540<\/td><\/tr>\n    <tr><td>6<\/td><td>1F\u95e8\u5385 36\u4e09\u7ba1\u5236<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>5,238<\/td><td>4,190<\/td><td>2,100<\/td><td>6,290<\/td><\/tr>\n    <tr><td>7<\/td><td>1F\u8001\u4eba\u623f 22\u4e09\u7ba1\u5236<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>5,050<\/td><td>4,040<\/td><td>2,100<\/td><td>6,140<\/td><\/tr>\n    <tr><td>8<\/td><td>2F\u4e3b\u5367 40\u4e09\u7ba1\u5236<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>5,238<\/td><td>4,190<\/td><td>2,100<\/td><td>6,290<\/td><\/tr>\n    <tr><td>9<\/td><td>2F\u4e3b\u536b \u536b\u6d74\u4e13\u7528<\/td><td>RCIS-25FSWNQD<\/td><td>7,088<\/td><td>5,670<\/td><td>1,600<\/td><td>7,270<\/td><\/tr>\n    <tr><td>10<\/td><td>2F\u4e66\u623f 32\u4e09\u7ba1\u5236<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>5,238<\/td><td>4,190<\/td><td>2,100<\/td><td>6,290<\/td><\/tr>\n    <tr><td>11<\/td><td>2F\u8336\u5ba4 28\u4e09\u7ba1\u5236<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>5,050<\/td><td>4,040<\/td><td>2,100<\/td><td>6,140<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\">\u5ba4\u5185\u673a\u5c0f\u8ba1\uff089\u53f0\uff09<\/td><td>58,350<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:14px 0 4px;\">\n    <strong>\u7cfb\u7edf\u4e00\u5408\u8ba1\uff08280\u4e00\u62d6\u4e5d + \u6c34\u6a21\u5757\uff09\uff1a\u00a598,655<\/strong>\n  <\/div>\n\n  <h3 id=\"s4-s2\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u7cfb\u7edf\u4e8c\uff1a\u5c0a\u777f\u5168\u6548160 + \u6c34\u6a21\u5757160 \u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b\uff083F-4F \u5b50\u5973\u56de\u5bb6\u533a\uff09<\/h3>\n\n  <h4 style=\"margin:12px 0 6px;color:var(--lm-gold2);\">1. \u5ba4\u5916\u673a + \u6c34\u6a21\u5757<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>\u6298\u6263<\/th><th>\u6298\u540e\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u5c0a\u777f\u5168\u6548\u5ba4\u5916\u673a<\/td><td>RAS-160FSXPNY5Q<\/td><td>20,600<\/td><td>8\u6298<\/td><td>16,480<\/td><td>\u5df2\u542b<\/td><td>16,480<\/td><\/tr>\n    <tr><td>2<\/td><td>\u6c34\u6a21\u5757160<\/td><td>RWMG-160FWXNZQ<\/td><td>8,375<\/td><td>\u4e0d\u6253\u6298<\/td><td>8,375<\/td><td>625<\/td><td>9,000<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"7\">\u4e3b\u673a\u5c0f\u8ba1<\/td><td>25,480<\/td><\/tr>\n  <\/table>\n\n  <h4 style=\"margin:16px 0 6px;color:var(--lm-gold2);\">2. \u5ba4\u5185\u673a\uff08\u4e00\u62d6\u4e94\uff09<\/h4>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u533a\u57df<\/th><th>\u578b\u53f7<\/th><th>\u9762\u4ef7<\/th><th>8\u6298<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>3<\/td><td>3F\u513f\u7ae5\u623f 45\u4e09\u7ba1\u5236<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>5,563<\/td><td>4,450<\/td><td>2,100<\/td><td>6,550<\/td><\/tr>\n    <tr><td>4<\/td><td>3F\u7535\u7ade\u623f 28\u4e09\u7ba1\u5236<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>5,050<\/td><td>4,040<\/td><td>2,100<\/td><td>6,140<\/td><\/tr>\n    <tr><td>5<\/td><td>3F\u8d77\u5c45\u5ba4 32\u4e09\u7ba1\u5236<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>5,238<\/td><td>4,190<\/td><td>2,100<\/td><td>6,290<\/td><\/tr>\n    <tr><td>6<\/td><td>4F\u50a8\u85cf\u5ba4 22\u4e8c\u7ba1\u5236<\/td><td>RPIZ-22FSVNZ1QD\/PC<\/td><td>4,600<\/td><td>3,680<\/td><td>1,800<\/td><td>5,480<\/td><\/tr>\n    <tr><td>7<\/td><td>4F\u591a\u529f\u80fd\u5ba4 71\u4e8c\u7ba1\u5236<\/td><td>RPIZ-71FSVNZ1QD\/PC<\/td><td>5,238<\/td><td>4,190<\/td><td>1,800<\/td><td>5,990<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\">\u5ba4\u5185\u673a\u5c0f\u8ba1\uff085\u53f0\uff09<\/td><td>30,450<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:14px 0 4px;\">\n    <strong>\u7cfb\u7edf\u4e8c\u5408\u8ba1\uff08160\u4e00\u62d6\u4e94 + \u6c34\u6a21\u5757\uff09\uff1a\u00a555,930<\/strong>\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5730\u6696\u7cfb\u7edf\uff08\u5168\u5c4b370\u33a1 \u00b7 \u50a8\u85cf\u5ba4\u9664\u5916\uff09<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7<\/th><th>\u9762\u79ef<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8<\/td><td>De32\u4e3b\u7ba1+De20\u76d8\u7ba1\/\u4f1f\u661f\u963b\u6c27\u7ba1\/\u66fc\u745e\u5fb7\u8054\u52a8\u63a7\u5236<\/td><td>179\u5143\/\u33a1<\/td><td>370\u33a1<\/td><td>66,230<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"4\">\u5730\u6696\u5c0f\u8ba1<\/td><td>66,230<\/td><\/tr>\n  <\/table>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\uff08\u5168\u5c4b\u751f\u6d3b\u70ed\u6c34 \u00b7 \u53cc\u536b\u540c\u65f6\u4f7f\u7528\uff09<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7\/\u89c4\u683c<\/th><th>\u4ef7\u683c<\/th><th>\u6298\u6263<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n    <tr><td>1<\/td><td>\u7f8e\u56fd\u745e\u7f8e\u71c3\u6c14\u70ed\u6c34\u5668<\/td><td>JSQ40-LX(T) 20L\/min<\/td><td>5,999<\/td><td>\u4e0d\u6253\u6298\uff08\u5355\u4ef7\uff09<\/td><td>\u5df2\u542b<\/td><td>5,999<\/td><\/tr>\n    <tr><td>2<\/td><td>\u5a01\u4e50\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5<\/td><td>\u53d8\u9891\u6c34\u6cf5<\/td><td>1,200<\/td><td>\u4e0d\u6253\u6298<\/td><td>\u5df2\u542b<\/td><td>1,200<\/td><\/tr>\n    <tr><td>3<\/td><td>\u7f8e\u56fd\u745e\u7f8e\u6362\u70ed\u6c34\u7bb1<\/td><td>150L\u5bb9\u79ef\u5f0f<\/td><td>2,600<\/td><td>\u4e0d\u6253\u6298<\/td><td>1,200<\/td><td>3,800<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td colspan=\"6\">\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\u5c0f\u8ba1<\/td><td>10,999<\/td><\/tr>\n  <\/table>\n  <div class=\"lm-highlight-blue\" style=\"margin:8px 0 16px;font-size:13px;\">\n    <strong>\u8bf4\u660e\uff1a<\/strong>\u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\uff085,999\u5143\uff09\u53ca\u5a01\u4e50\u5faa\u73af\u6cf5\uff081,200\u5143\uff09\u4ef7\u683c\u6765\u6e90\u4e8e\u9f99\u8109\u6696\u901a\u4ef7\u683c\u5e93\uff08page_id=662\uff09\uff1b\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1\u8bbe\u5907\u4ef72,600\u5143+\u5b89\u88c5\u8d391,200\u5143\uff0c\u6700\u7ec8\u603b\u4ef7\u4ee5\u7b7e\u7ea6\u786e\u8ba4\u4e3a\u51c6\u3002\n  <\/div>\n\n  <h3 id=\"s4-sum\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u6c47\u603b<\/h3>\n  <table class=\"lm-table\">\n    <tr><th style=\"width:60%;\">\u9879\u76ee<\/th><th style=\"width:40%;\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr>\n    <tr><td>\u7cfb\u7edf\u4e00\uff1a\u5c0a\u777f\u5168\u6548280\uff08\u4e00\u62d6\u4e5d+\u6c34\u6a21\u5757\uff09<\/td><td>98,655<\/td><\/tr>\n    <tr><td>\u7cfb\u7edf\u4e8c\uff1a\u5c0a\u777f\u5168\u6548160\uff08\u4e00\u62d6\u4e94+\u6c34\u6a21\u5757\uff09<\/td><td>55,930<\/td><\/tr>\n    <tr><td>\u5730\u6696\u7cfb\u7edf\uff08370\u33a1 \u00b7 \u50a8\u85cf\u5ba4\u9664\u5916\uff09<\/td><td>66,230<\/td><\/tr>\n    <tr><td>\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\uff08\u70ed\u6c34\u5668+\u5faa\u73af\u6cf5+\u6362\u70ed\u6c34\u7bb1\uff09<\/td><td>10,999<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u8bbe\u5907\u5408\u8ba1\uff08\u542b\u5b89\u88c5\u8d39\uff09<\/td><td>231,814<\/td><\/tr>\n    <tr><td colspan=\"2\" style=\"background:rgba(212,160,23,.10);\">\u6ce8\uff1a\u4ee5\u4e0a\u4e3a\u8bbe\u5907+\u5b89\u88c5\u8d39\u5408\u8ba1\uff1b\u4e0d\u542b\u5ba4\u5916\u673a\u540a\u88c5\u8d39\u3001\u8fdc\u7a0b\u8d39\u3001\u7a0e\u91d1\u53ca\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\uff0c\u4ee5\u5b9e\u9645\u7b7e\u7ea6\u4e3a\u51c6\u3002<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-chart-box\">\n    <div class=\"lm-chart-title\">\u8bbe\u5907\u62a5\u4ef7\u6784\u6210\uff08\u5143\uff09<\/div>\n    <div class=\"lm-chart\" id=\"lmPriceChart\"><\/div>\n  <\/div>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u4ef7\u683c\u8bf4\u660e\uff1a<\/strong><br>\n    1. \u4ee5\u4e0a\u4ef7\u683c\u4e3a\u8bbe\u5907+\u5b89\u88c5\u8d39\u5408\u8ba1\uff0c\u6309\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee402 V5.0\u6267\u884c\uff1b<br>\n    2. \u5c0a\u777f\u5168\u6548\u5ba4\u5916\u673a\u53ca\u5168\u90e8\u5185\u673a\uff08\u4e09\u7ba1\u5236\/\u4e8c\u7ba1\u5236\/\u53a8\u623f\u4e13\u7528\/\u536b\u6d74\u4e13\u7528\uff09\u4eab 8\u6298 \u4f18\u60e0\uff1b<br>\n    3. \u6c34\u6a21\u5757\u4e3a\u4e0d\u6253\u6298\u4ea7\u54c1\uff0c\u4ee5\u9762\u4ef7\u8ba1\uff1b\u745e\u7f8e\u70ed\u6c34\u5668JSQ40-LX(T)\u4e3a\u5355\u4ef7\u4ea7\u54c1\uff085,999\u5143\uff0c\u4e0d\u6253\u6298\uff09\uff1b\u5a01\u4e50\u5faa\u73af\u6cf51,200\u5143\uff08\u4e0d\u6253\u6298\uff09\uff1b<br>\n    4. \u5b89\u88c5\u8d39\uff1a\u4e09\u7ba1\u5236\u5185\u673a 2,100\u5143\/\u53f0\u3001\u4e8c\u7ba1\u5236\u5185\u673a 1,800\u5143\/\u53f0\u3001\u53a8\u623f\/\u536b\u6d74\u4e13\u7528\u5185\u673a 1,600\u5143\/\u53f0\u3001\u5916\u673a 600\u5143\u3001\u6c34\u6a21\u5757 625\u5143\uff08\u5747\u4e0d\u6253\u6298\uff09\uff1b\u745e\u7f8e\u70ed\u6c34\u5668\u53ca\u5a01\u4e50\u5faa\u73af\u6cf5\u5b89\u88c5\u8d39\u5df2\u542b\uff0c\u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1\u5b89\u88c5\u8d391,200\u5143\uff1b<br>\n    5. \u745e\u7f8e150L\u6362\u70ed\u6c34\u7bb1\u8bbe\u5907\u4ef72,600\u5143\uff08\u4e0d\u6253\u6298\uff09\uff0c\u5b89\u88c5\u8d391,200\u5143\uff1b<br>\n    6. \u5b89\u88c5\u8f85\u6750\u8be6\u89c1\u4e0b\u65b9\u8f85\u6750\u914d\u7f6e\u6e05\u5355\uff1b<br>\n    7. \u672c\u62a5\u4ef7\u6709\u6548\u671f30\u5929\uff0c\u6700\u7ec8\u4ef7\u683c\u4ee5\u7b7e\u7ea6\u786e\u8ba4\u4e3a\u51c6\u3002\n  <\/div>\n<h3 id=\"s4-mat\" style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355<\/h3>\n  <p style=\"color:var(--lm-text2);margin-bottom:12px;font-size:14px;\">\u4ee5\u4e0b\u8f85\u6750\u6e05\u5355\u6309\u6307\u4ee406 V2.0\u89c4\u8303\u8f93\u51fa\uff0c\u4ec5\u5217\u54c1\u724c\u89c4\u683c\uff0c\u4e0d\u542b\u4ef7\u683c\u3002\u70b9\u51fb\u5c55\u5f00\u67e5\u770b\u3002<\/p>\n\n  <div class=\"lm-acc\">\n    <div class=\"lm-acc-item lm-open\">\n      <div class=\"lm-acc-head\">\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u5c0a\u777f\u5168\u6548\u00b71F-4F \u53cc\u7cfb\u7edf\uff09<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1\uff0c\u8f93\u9001\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1\uff0c\u8f93\u9001\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><\/tr>\n          <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>12\u94dc\u7ba1\u53ca\u4ee5\u4e0b15mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>16\u94dc\u7ba1\u53ca\u4ee5\u4e0a20mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n          <tr><td>\u5b9a\u5236<\/td><td>\u540a\u5361\u4e0e\u652f\u67b6<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u67b6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u8def\u5b89\u88c5<\/td><\/tr>\n          <tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr>\n          <tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr>\n          <tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5\/\u8fd0\u8f93<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\/\u8fd0\u8f93<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6599\uff08\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u00b71F-4F \u53cc\u7cfb\u7edf\uff09<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <h4 style=\"margin:8px 0 6px;color:var(--lm-gold2);\">\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6599\u90e8\u5206<\/h4>\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u53bb\u6cb9\u94dc\u7ba1<\/td><\/tr>\n          <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u2014<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><\/tr>\n          <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n          <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea615\/20mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\u4e3b\u7ba1\u90e8\u5206<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u4e3b\u7ba1<\/td><td>dn32*en2.9\/dn40*en3.7\/dn50*en4.6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u9009\u62e9<\/td><\/tr>\n          <tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u03c632*20\/\u03c640*20\/\u03c650*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29\uff0c\u51cf\u5c11\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c421\u4e2a<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u94dc\u8d28\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\uff0c\u5206\u8def\u63a7\u5236<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u4e00\u4f53\u89d2\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u65b9\u4fbf\u68c0\u4fee<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\/\u76f4\u63a5\/\u5f2f\u5934<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u5b89\u5168\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u6c34\u538b<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a<\/td><\/tr>\n          <tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u81ea\u52a8\u8865\u6c34\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u8bc1\u7cfb\u7edf\u6c34\u91cf\u5145\u8db3<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u6b63\u53d1<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>40\u76ee<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fc7\u6ee4\u6742\u8d28<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\u5730\u9762\u90e8\u5206<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u6563\u5931<\/td><\/tr>\n          <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u91c7\u6696\u7cfb\u7edf\u63a7\u5236\u90e8\u5206<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u65e5\u7acb<\/td><td>\u6c34\u6e29\u63a7\u5236\u5668<\/td><td>PC-WHM2Q\/PC-WHM3Q<\/td><td>2<\/td><td>\u8c03\u8282\u4e24\u5957\u91c7\u6696\u6c34\u6e29\uff08\u6bcf\u7cfb\u7edf1\u4e2a\uff09<\/td><\/tr>\n          <tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u5b50\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr>\n          <tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>2*1.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u63a7\u5236\u7ebf<\/td><\/tr>\n          <tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>PVC\u5957\u7ba1<\/td><td>\u03c616<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\u8f85\u6750<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u7f8e\u56fd\u745e\u7f8e<\/td><td>\u71c3\u6c14\u70ed\u6c34\u5668<\/td><td>JSQ40-LX(T) 20L\/min<\/td><td>1\u53f0<\/td><td>\u4e09\u8054\u4f9b\u51ac\u5b63\u91c7\u6696\u5b63\u751f\u6d3b\u70ed\u6c34\u70ed\u6e90<\/td><\/tr>\n          <tr><td>\u7f8e\u56fd\u745e\u7f8e<\/td><td>\u6362\u70ed\u6c34\u7bb1<\/td><td>150L\u5bb9\u79ef\u5f0f<\/td><td>1\u53f0<\/td><td>\u50a8\u80fd\u7f13\u51b2\uff0c\u70ed\u6cf5\/\u71c3\u6c14\u70ed\u6c34\u5668\u5747\u53ef\u52a0\u70ed<\/td><\/tr>\n          <tr><td>\u5a01\u4e50<\/td><td>\u667a\u80fd\u70ed\u6c34\u5faa\u73af\u6cf5<\/td><td>\u53d8\u9891\u6c34\u6cf5<\/td><td>1\u53f0<\/td><td>\u70ed\u6c34\u7ba1\u8def\u56de\u6c34\u5faa\u73af\uff0c\u5373\u5f00\u5373\u70ed<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u70ed\u6c34PPR\u7ba1<\/td><td>dn20\/dn25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u70ed\u6c34\u4f9b\u6c34\/\u56de\u6c34\u7ba1\u8def<\/td><\/tr>\n          <tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u9002\u914d\u7ba1\u5f84<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u70ed\u6c34\u7ba1\u8def\u4fdd\u6e29\uff0c\u51cf\u5c11\u70ed\u91cf\u635f\u5931<\/td><\/tr>\n          <tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5faa\u73af\u6cf5\/\u70ed\u6c34\u5668\u914d\u7535<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n    <div class=\"lm-acc-item\">\n      <div class=\"lm-acc-head\">\u670d\u52a1\u4fdd\u969c<span class=\"lm-acc-ico\">+<\/span><\/div>\n      <div class=\"lm-acc-body\"><div class=\"lm-acc-body-inner\">\n        <table class=\"lm-table\">\n          <tr><th>\u54c1\u724c<\/th><th>\u540d\u79f0<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr>\n          <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1\/\u51fa\u56fe\/\u5b9a\u4f4d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d\u7b49<\/td><\/tr>\n          <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4f1f\u661f\u5382\u5bb6\u7b2c\u4e09\u65b9\u76d1\u7406\uff0c\u542b\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr>\n          <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr>\n        <\/table>\n      <\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-highlight-blue\" style=\"margin:16px 0;font-size:13px;\">\n    <strong>\u8f85\u6750\u8bf4\u660e\uff1a<\/strong><br>\n    1. \u4ee5\u4e0a\u8f85\u6750\u5747\u4e3a\u9ed8\u8ba4\u89c4\u683c\uff0c\u54c1\u724c\u4e0d\u53ef\u66ff\u6362\uff0c\u89c4\u683c\u4e0d\u53ef\u865a\u6784\uff1b<br>\n    2. \u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6570\u91cf\u4ee5\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff1b<br>\n    3. \u8f85\u6750\u4e0d\u6d89\u53ca\u62a5\u4ef7\u91d1\u989d\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff1b<br>\n    4. \u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3001\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff1b<br>\n    5. \u5982\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u52a8\u7528\u540a\u88c5\u8bbe\u5907\uff0c\u8d39\u7528\u53e6\u8ba1\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== S5\u00b7\u6848\u4f8b\u9a8c\u8bc1 ===== -->\n<section class=\"lm-section\" id=\"s5\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">S5<\/span>\u6848\u4f8b\u9a8c\u8bc1<\/div>\n\n  <p style=\"color:var(--lm-text2);margin-bottom:12px;\">\u4ee5\u4e0b\u6848\u4f8b\u5747\u4e3a\u9f99\u8109\u6696\u901a\u771f\u5b9e\u4ea4\u4ed8\u7684<strong style=\"color:var(--lm-gold2);\">\u5c0a\u777f\u5168\u6548\uff08\u5929\u6c1f\u5730\u6c34 \/ \u4e09\u7ba1\u5236\uff09<\/strong>\u9879\u76ee\uff0c\u53ef\u5728\u5b98\u7f51\u6848\u4f8b\u5e93\u67e5\u8be2\u9a8c\u8bc1\uff0c\u4e0e\u672c\u6848\u65b9\u6848\u9ad8\u5ea6\u540c\u6e90\uff08\u540c\u5c5e\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757+\u4e09\u7ba1\u5236\u5185\u673a\uff09\u3002<\/p>\n\n  <table class=\"lm-table\">\n    <tr><th>\u6848\u4f8b<\/th><th>\u9762\u79ef \/ \u7c7b\u578b<\/th><th>\u7cfb\u7edf\u914d\u7f6e<\/th><th>\u53c2\u8003\u4ef7\u503c<\/th><\/tr>\n    <tr>\n      <td><a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=5008\" target=\"_blank\">\u4e2d\u6d77\u00b7\u4e5d\u53f7\u516c\u9986 8-1-1101<\/a><\/td>\n      <td>\u5927\u5e73\u5c42 \u00b7 \u91c7\u6696\u7ea6200\u33a1<br>\u4e09\u5b69\u5bb6\u5ead6-7\u4eba<\/td>\n      <td>\u5c0a\u777f\u5168\u6548II RAS-224 + \u6c34\u6a21\u5757 + \u4f1f\u661fA+\u7ed9\u6c34 + \u5730\u6696192\u33a1\uff08\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff09<\/td>\n      <td>\u591a\u4ee3\u540c\u5802 \/ \u9ad8\u4eba\u6570\u70ed\u6c34\u4e0e\u9664\u6e7f\u573a\u666f\u6807\u6746\uff0c\u4e0e\u672c\u6848\u540c\u5c5e\u5c0a\u777f\u5168\u6548\u5929\u6c1f\u5730\u6c34\u65b9\u6848<\/td>\n    <\/tr>\n    <tr>\n      <td><a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=448\" target=\"_blank\">\u548c\u8d35\u5357\u5c71\u4e0a\u00b7\u8f9b\u603b\u522b\u5885<\/a><\/td>\n      <td>\u72ec\u680b\u522b\u5885 \u00b7 600\u33a1<\/td>\n      <td>\u5c0a\u777f\u5168\u6548504\u4e3b\u673a + \u745e\u7f8e\u53cc\u51b7\u51dd\u9505\u7089 + 15\u53f0\u5185\u673a + 450\u33a1\u5730\u6696<\/td>\n      <td>\u522b\u5885\u5927\u5b85\u7cfb\u7edf\u6807\u6746\uff1a450\u33a1\u5730\u6696\u6708\u71c3\u6c14\u8d39\u4e0d\u8db32000\u5143\uff0c\u9a8c\u8bc1\u5c0a\u777f\u5730\u6696\u8fd0\u884c\u7ecf\u6d4e\u6027<\/td>\n    <\/tr>\n    <tr>\n      <td><a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com?p=2977\/\" target=\"_blank\">\u5927\u6eaa\u8c37\u9e6d\u5cad\u00b7\u9f9a\u5973\u58eb\u5c71\u8fb9\u522b\u5885<\/a><\/td>\n      <td>\u53e0\u62fc\u522b\u5885 \u00b7 180\u33a1<br>\u91c7\u6696136\u33a1<\/td>\n      <td>\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b\uff08\u5929\u6c1f\u5730\u6c34\u00b7\u4e09\u7ba1\u5236\u6e29\u6e7f\u5e73\u8861\uff09\u4e00\u62d6\u4e94 + \u5730\u6696<\/td>\n      <td>\u4e09\u7ba1\u5236\u6e29\u6e7f\u5e73\u8861 + \u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u4e0e\u672c\u6848\u4e09\u7ba1\u5236\u5185\u673a\u65b9\u6848\u9ad8\u5ea6\u5951\u5408<\/td>\n    <\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u6848\u4f8b\u9a8c\u8bc1\u8bf4\u660e\uff1a<\/strong>\u4ee5\u4e0a\u6848\u4f8b\u5747\u53ef\u5728\u9f99\u8109\u6696\u901a\u5b98\u7f51\u6848\u4f8b\u5e93\uff08<a class=\"lm-case-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">longmai-nt.com\/?page_id=2297<\/a>\uff09\u67e5\u8be2\u9a8c\u8bc1\u3002\u674e\u5973\u58eb\u9879\u76ee\u7684\u65b9\u6848\u6570\u636e\u4e5f\u5c06\u8131\u654f\u540e\u5165\u5e93\uff0c\u6210\u4e3a\u672a\u6765\u540c\u6237\u578b\u5ba2\u6237\u7684\u53c2\u8003\u6807\u6746\u3002\n  <\/div>\n\n  <h3 style=\"margin:24px 0 12px;color:var(--lm-gold2);\">\u552e\u540e\u4fdd\u969c\u4e0e\u8d28\u4fdd\u4f53\u7cfb<\/h3>\n  <table class=\"lm-table\">\n    <tr><th>\u9879\u76ee<\/th><th>\u8d28\u4fdd\u671f\u9650<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u8bbe\u5907\uff08\u5ba4\u5916\u673a+\u5185\u673a+\u6c34\u6a21\u5757\uff09<\/td><td>6\u5e74<\/td><td>\u65e5\u7acb\u5382\u5bb6\u6807\u51c6\u6574\u673a\u8d28\u4fdd\uff08\u542b\u538b\u7f29\u673a\uff09\uff0c\u884c\u4e1a\u9886\u5148\u6807\u51c6<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u65e5\u7acb\u5382\u5bb6\u54c1\u724c\u6708\u6d3b\u52a8 \u00b7 \u5ef6\u4fdd<\/td><td>\u5ef6\u4fdd\u81f3 10\u5e74<\/td><td>\u53c2\u4e0e\u65e5\u7acb\u5382\u5bb6\u54c1\u724c\u6708\u6d3b\u52a8\uff0c\u6574\u673a\u8d28\u4fdd\u7531\u6807\u51c66\u5e74\u5ef6\u957f\u81f310\u5e74<\/td><\/tr>\n    <tr><td>\u4f1f\u661f\u5730\u6696 \/ \u7a7a\u8c03\u7ba1\u8def\u7cfb\u7edf<\/td><td>50\u5e74<\/td><td>\u4f1f\u661f\u5382\u5bb6 + \u4fdd\u9669\u516c\u53f8 + \u9f99\u8109 \u4e09\u65b9\u8054\u4fdd\uff08\u4ea7\u54c1 + \u5b89\u88c5 + \u4fdd\u9669\uff09<\/td><\/tr>\n    <tr><td>\u9f99\u8109\u5b89\u88c5\u5de5\u7a0b<\/td><td>2\u5e74<\/td><td>\u9690\u853d\u5de5\u7a0b\u7ec8\u8eab\u8d1f\u8d23\u5236<\/td><\/tr>\n    <tr class=\"lm-row-hl\"><td>\u9f99\u7684\u5341\u5e74\u80fd\u6e90\u4fdd\u969c\u670d\u52a1<\/td><td>10\u5e74<\/td><td>\u9f99\u8109\u4e13\u5c5e\u80fd\u6e90\u4fdd\u969c\uff1a10\u5e74\u5185\u56e0\u8bbe\u8ba1 \/ \u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u80fd\u8017\u5f02\u5e38\uff0c\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u8c03\u6574\uff0c\u5e74\u5ea6\u80fd\u8017\u5bf9\u6807<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight-green\" style=\"margin:16px 0;\">\n    <strong>\u9f99\u7684\u5341\u5e74\u80fd\u6e90\u4fdd\u969c\u670d\u52a1 \u00b7 \u674e\u5973\u58eb\u5bb6\u52a0\u5165 A \u7ec4\uff08\u8282\u80fd\u65b9\u6848\u7ec4\uff09\uff0c\u4eab\u53d7\u4ee5\u4e0b\u4e13\u5c5e\u4fdd\u969c\uff1a<\/strong><br>\n    1. \u6bcf\u5e74\u91c7\u6696\u5b63\u540e\u4e3b\u52a8\u56de\u8bbf\uff0c\u91c7\u96c6\u80fd\u8017\u6570\u636e\uff1b<br>\n    2. \u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807\u5206\u6790\uff0c\u63d0\u4f9b\u8282\u80fd\u4f18\u5316\u5efa\u8bae\uff08\u5bf9\u6bd4\u73b0\u72b6 15,000 \u5143\/\u5e74\u91c7\u6696\u57fa\u51c6 + \u4e09\u8054\u4f9b\u70ed\u6c34\u7701\u6c14\u6548\u679c\u8bc4\u4f30\uff09\uff1b<br>\n    3. <strong>10\u5e74\u5185<\/strong>\u82e5\u56e0\u8bbe\u8ba1\u6216\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u80fd\u8017\u5f02\u5e38\uff0c\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u8c03\u6574\uff1b<br>\n    4. \u6570\u636e\u8131\u654f\u540e\u533f\u540d\u4f7f\u7528\uff0c\u4fdd\u62a4\u5ba2\u6237\u9690\u79c1\uff1b<br>\n    5. \u552e\u540e\u95ee\u9898\u53cd\u9988\u81f3\u5ba2\u6237\u6863\u6848\uff0c\u53cd\u63a8\u65b9\u6848\u6807\u51c6\u66f4\u65b0\u3002\n  <\/div>\n\n  <table class=\"lm-table\">\n    <tr><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u54cd\u5e94\u6807\u51c6<\/th><th>\u8bf4\u660e<\/th><\/tr>\n    <tr><td>\u7d27\u6025\u62a5\u4fee<\/td><td>24\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><td>\u7cfb\u7edf\u6545\u969c\u3001\u6f0f\u6c34\u3001\u4e0d\u5236\u51b7\/\u5236\u70ed\u7b49\u7d27\u6025\u95ee\u9898<\/td><\/tr>\n    <tr><td>\u5e38\u89c4\u7ef4\u4fdd<\/td><td>48\u5c0f\u65f6\u5185\u5b89\u6392<\/td><td>\u6ee4\u7f51\u6e05\u6d17\u3001\u7cfb\u7edf\u68c0\u67e5\u3001\u53c2\u6570\u8c03\u8bd5<\/td><\/tr>\n    <tr><td>\u5e74\u5ea6\u56de\u8bbf<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u540e<\/td><td>\u80fd\u8017\u6570\u636e\u91c7\u96c6+\u7cfb\u7edf\u5065\u5eb7\u68c0\u67e5+\u4f18\u5316\u5efa\u8bae<\/td><\/tr>\n    <tr><td>\u8fdc\u7a0b\u8bca\u65ad<\/td><td>\u5373\u65f6<\/td><td>\u901a\u8fc7\u7535\u8bdd\/\u89c6\u9891\u8fdc\u7a0b\u6307\u5bfc\u6392\u67e5\u8fd0\u884c\u95ee\u9898\uff0c\u5feb\u901f\u5b9a\u4f4d<\/td><\/tr>\n  <\/table>\n\n  <div class=\"lm-highlight\" style=\"margin:16px 0;\">\n    <strong>\u53cd\u9988\u673a\u5236\uff1a<\/strong>\u505a\u5b8c\u4e00\u4ef6\u4e8b\uff0c\u5fc5\u987b\u628a\u7ed3\u679c\u586b\u56de\u6765\u3002\u674e\u5973\u58eb\u9879\u76ee\u7684\u6240\u6709\u65bd\u5de5\u6570\u636e\u3001\u9a8c\u6536\u8bb0\u5f55\u3001\u80fd\u8017\u6570\u636e\u5747\u5f55\u5165\u5ba2\u6237\u6210\u529f\u6863\u6848\uff0c\u4f5c\u4e3a\u672a\u6765\u540c\u7c7b\u578b\u9879\u76ee\u7684\u53c2\u8003\u6807\u6746\u3002\u552e\u540e\u95ee\u9898\u53cd\u63a8\u81f3\u65b9\u6848\u6807\u51c6\uff0c\u6301\u7eed\u4f18\u5316\u77e5\u8bc6\u5e93\u3002\n  <\/div>\n<\/section>\n\n<!-- ===== \u9644\u5f55\u00b7\u54c1\u724c\u6388\u6743 ===== -->\n<section class=\"lm-section\" id=\"sa\">\n  <div class=\"lm-section-title\"><span class=\"lm-num\">\u9644<\/span>\u54c1\u724c\u6388\u6743<\/div>\n  <p style=\"color:var(--lm-text2);margin-bottom:16px;\">\u9f99\u8109\u6696\u901a\u6301\u6709\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u8d44\u8d28\uff0c\u4ee5\u4e0b\u4e3a\u76f8\u5173\u6388\u6743\u8bc1\u4e66\u5b9e\u62cd\uff1a<\/p>\n  <div class=\"lm-img-row\" id=\"sa-cert\">\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u94bb\u77f3\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u7279\u7ea6\u7ecf\u9500\u5546\u6388\u6743\uff082026\uff09<\/div>\n    <\/div>\n    <div class=\"lm-img-card\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\">\n      <div class=\"lm-img-label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u91d1\u724c\u5b89\u88c5\u670d\u52a1\u6388\u6743\uff082024\uff09<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u8054\u7cfb\u6211\u4eec ===== -->\n<section class=\"lm-section lm-contact-footer\" id=\"s10\">\n  <div class=\"lm-cf-header\">\n    <div class=\"lm-cf-title\"><span class=\"lm-phone-icon\">\u260e<\/span>\u8054\u7cfb\u6211\u4eec<\/div>\n    <div class=\"lm-cf-sub\">\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u91cf\u623f\u5b9a\u5236\u7cfb\u7edf\u65b9\u6848 \u00b7 \u7cbe\u5de5\u516d\u6b65\u6cd5\u6807\u51c6\u65bd\u5de5<\/div>\n  <\/div>\n\n  <div class=\"lm-cf-contacts\" id=\"s10-contact\">\n    <a href=\"tel:028-86131795\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u5357\u5bcc\u68ee\u5e97<\/span><span class=\"lm-phone\">028-86131795<\/span><\/div>\n    <\/a>\n    <a href=\"tel:028-65272586\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u5317\u5bcc\u68ee\u5e97<\/span><span class=\"lm-phone\">028-65272586<\/span><\/div>\n    <\/a>\n    <a href=\"tel:028-65272586\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u552e\u540e\u4e13\u7ebf<\/span><span class=\"lm-phone\">028-65272586<\/span><\/div>\n    <\/a>\n    <a href=\"tel:13008113409\" class=\"lm-cf-contact\">\n      <div class=\"lm-ic\">\u260e<\/div>\n      <div class=\"lm-info\"><span class=\"lm-label\">\u672c\u6848\u987e\u95ee\u4f59\u6653\u73b2<\/span><span class=\"lm-phone\">130-0811-3409<\/span><\/div>\n    <\/a>\n  <\/div>\n\n  <div class=\"lm-cf-services\">\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u4e0a\u95e8\u5b9e\u5730\u52d8\u6d4b<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>\u4e13\u5c5e\u6237\u578b\u65b9\u6848\u62a5\u4ef7<\/div>\n    <div class=\"lm-cf-service\"><span class=\"lm-ck\">\u2713<\/span>36\u9879\u65bd\u5de5\u8282\u70b9\u9a8c\u6536<\/div>\n  <\/div>\n\n  <div class=\"lm-cf-stores\">\n    <div class=\"lm-cf-store\">\n      <div class=\"lm-store-label\"><span class=\"lm-pin\">\u25c6<\/span>\u5357\u5bcc\u68ee\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u5e97\">\n      <div class=\"lm-store-addr\"><span class=\"lm-pin\">\u25c6<\/span>\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/div>\n    <\/div>\n    <div class=\"lm-cf-store\">\n      <div class=\"lm-store-label\"><span class=\"lm-pin\">\u25c6<\/span>\u5317\u5bcc\u68ee\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u5e97\">\n      <div class=\"lm-store-addr\"><span class=\"lm-pin\">\u25c6<\/span>\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u99865\u697cA5135\u53f7<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-cf-service-area\">\n    <span class=\"lm-label\">\u670d\u52a1\u8986\u76d6\u533a\u53bf\uff1a<\/span>\u65b0\u90fd \u00b7 \u53cc\u6d41 \u00b7 \u90eb\u90fd \u00b7 \u90eb\u57ce \u00b7 \u6b66\u4faf \u00b7 \u6210\u534e \u00b7 \u5f6d\u5dde \u00b7 \u9f99\u6cc9 \u00b7 \u6e29\u6c5f \u7b49\u5168\u5883\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u65bd\u5de5\n  <\/div>\n\n  <div class=\"lm-cf-cta\">\n    <a href=\"tel:13008113409\" class=\"lm-btn\">\u514d\u8d39\u9884\u7ea6\u52d8\u6d4b \u2192<\/a>\n  <\/div>\n\n  <div class=\"lm-cf-footer-note\">* \u5177\u4f53\u9700\u7528\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u5dee\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/div>\n<\/section>\n\n<\/div>\n\n<script src=\"https:\/\/cdn.jsdelivr.net\/npm\/echarts@5.5.0\/dist\/echarts.min.js\"><\/script>\n<script>\n\/\/ ===== \u60ac\u6d6e\u5bfc\u822a\u9ad8\u4eae\uff08\u4e3b\u76ee\u5f55 + \u5b50\u76ee\u5f55\uff09 =====\nconst lmNavLinks = Array.from(document.querySelectorAll('.lm-toc-bar a'));\nconst lmNavPoints = lmNavLinks\n  .map(l => { const el = document.getElementById(l.getAttribute('href').slice(1)); return el ? { id: l.getAttribute('href').slice(1), el, link: l } : null; })\n  .filter(Boolean)\n  .sort((a, b) => a.el.offsetTop - b.el.offsetTop);\nfunction lmUpdateActive() {\n  const y = window.scrollY + 140;\n  let cur = lmNavPoints.length ? lmNavPoints[0].id : null;\n  for (const p of lmNavPoints) { if (p.el.offsetTop <= y) cur = p.id; }\n  lmNavLinks.forEach(l => l.classList.toggle('lm-active', l.getAttribute('href') === '#' + cur));\n  document.querySelectorAll('.lm-toc-group').forEach(g => g.classList.toggle('lm-group-active', !!g.querySelector('a.lm-active')));\n}\nwindow.addEventListener('scroll', lmUpdateActive, { passive: true });\nwindow.addEventListener('resize', lmUpdateActive);\nlmUpdateActive();\n\n\/\/ ===== \u79fb\u52a8\u7aef\uff1a\u70b9\u51fb\u4e3b\u76ee\u5f55\u5c55\u5f00\/\u6536\u8d77\u5b50\u76ee\u5f55\uff08\u684c\u9762\u7aef\u5141\u8bb8\u76f4\u63a5\u8df3\u8f6c\uff09 =====\ndocument.querySelectorAll('.lm-toc-group').forEach(g => {\n  const main = g.querySelector('.lm-toc-main');\n  main.addEventListener('click', e => {\n    if (window.innerWidth > 768) return;            \/\/ \u684c\u9762\u7aef\uff1a\u6b63\u5e38\u951a\u70b9\u8df3\u8f6c\n    if (!g.querySelector('.lm-toc-subs a')) return;  \/\/ \u65e0\u5b50\u76ee\u5f55\u4e0d\u62e6\u622a\n    e.preventDefault();\n    const wasOpen = g.classList.contains('lm-open');\n    document.querySelectorAll('.lm-toc-group').forEach(x => x.classList.remove('lm-open'));\n    if (!wasOpen) g.classList.add('lm-open');\n  });\n});\ndocument.addEventListener('click', e => {\n  if (window.innerWidth > 768) return;\n  if (!e.target.closest('.lm-toc-group') || e.target.closest('.lm-toc-subs a')) {\n    document.querySelectorAll('.lm-toc-group').forEach(x => x.classList.remove('lm-open'));\n  }\n});\n\n\/\/ ===== Tabs\uff08\u7cfb\u7edf\u5bf9\u6bd4\uff09 =====\ndocument.querySelectorAll('.lm-tab-btn').forEach(btn => {\n  btn.addEventListener('click', () => {\n    const tab = btn.dataset.tab;\n    document.querySelectorAll('.lm-tab-btn').forEach(b => b.classList.remove('lm-active'));\n    document.querySelectorAll('.lm-tab-panel').forEach(p => p.classList.remove('lm-active'));\n    btn.classList.add('lm-active');\n    document.getElementById(tab).classList.add('lm-active');\n  });\n});\n\n\/\/ ===== \u624b\u98ce\u7434\uff08\u8f85\u6750\u6e05\u5355\uff09 =====\ndocument.querySelectorAll('.lm-acc-head').forEach(head => {\n  head.addEventListener('click', () => {\n    head.parentElement.classList.toggle('lm-open');\n  });\n});\n\n\/\/ ===== \u8f6e\u64ad\uff08\u7cbe\u5de5\u516d\u6b65\u6cd5\uff09 =====\nconst lmCarTrack = document.querySelector('#lmCraftCarousel .lm-carousel-track');\nconst lmCarSlides = document.querySelectorAll('#lmCraftCarousel .lm-slide');\nconst lmCarDots = document.getElementById('lmCarDots');\nlet lmCarCur = 0;\nconst lmCarCnt = lmCarSlides.length;\nlmCarSlides.forEach((_, i) => {\n  const d = document.createElement('span');\n  d.className = 'lm-dot' + (i === 0 ? ' lm-active' : '');\n  d.addEventListener('click', () => lmCarGo(i));\n  lmCarDots.appendChild(d);\n});\nfunction lmCarGo(n) {\n  lmCarCur = (n + lmCarCnt) % lmCarCnt;\n  lmCarTrack.style.transform = 'translateX(-' + (lmCarCur * 100) + '%)';\n  document.querySelectorAll('#lmCarDots .lm-dot').forEach((d, i) => d.classList.toggle('lm-active', i === lmCarCur));\n}\n\n\/\/ ===== ECharts \u56fe\u8868 =====\nif (window.echarts) {\n  \/\/ \u62a5\u4ef7\u6784\u6210\u997c\u56fe\uff08\u6e05\u65b0\u6d45\u5e95\u914d\u8272\uff09\n  const priceChart = echarts.init(document.getElementById('lmPriceChart'));\n  priceChart.setOption({\n    backgroundColor: 'transparent',\n    tooltip: { trigger: 'item', formatter: '{b}: \u00a5{c} ({d}%)' },\n    legend: { bottom: 0, textStyle: { color: '#5a4d38' } },\n    series: [{\n      type: 'pie',\n      radius: ['38%', '66%'],\n      center: ['50%', '46%'],\n      itemStyle: { borderColor: '#ffffff', borderWidth: 2 },\n      label: { color: '#3a3326', fontSize: 12 },\n      data: [\n        { value: 98655, name: '\u5c0a\u777f280\u7cfb\u7edf\uff08\u4e00\u62d6\u4e5d+\u6c34\u6a21\u5757\uff09', itemStyle: { color: '#c89b3c' } },\n        { value: 55930, name: '\u5c0a\u777f160\u7cfb\u7edf\uff08\u4e00\u62d6\u4e94+\u6c34\u6a21\u5757\uff09', itemStyle: { color: '#e0b552' } },\n        { value: 66230, name: '\u5730\u6696\u7cfb\u7edf\uff08370\u33a1\uff09', itemStyle: { color: '#8a6d2f' } },\n        { value: 10999, name: '\u4e09\u8054\u4f9b\u70ed\u6c34\u7cfb\u7edf\uff08\u70ed\u6c34\u5668+\u5faa\u73af\u6cf5+\u6362\u70ed\u6c34\u7bb1\uff09', itemStyle: { color: '#6b8e23' } }\n      ]\n    }]\n  });\n  window.addEventListener('resize', () => priceChart.resize());\n}\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\u8212\u9002\u5065\u5eb7 \u00b7 \u8282\u80fd\u7a33\u5b9a \u00b7 \u7ef4\u62a4\u7b80\u4fbf \u5ba2 [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":2297,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-10122","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=10122\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u8212\u9002\u5065\u5eb7 \u00b7 \u8282\u80fd\u7a33\u5b9a \u00b7 \u7ef4\u62a4\u7b80\u4fbf \u5ba2 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=10122\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-14T11:29:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122\",\"name\":\"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\",\"datePublished\":\"2026-08-08T10:50:26+00:00\",\"dateModified\":\"2026-11-14T11:29:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10122#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2297\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=10122","og_locale":"zh_CN","og_type":"article","og_title":"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u8212\u9002\u5065\u5eb7 \u00b7 \u8282\u80fd\u7a33\u5b9a \u00b7 \u7ef4\u62a4\u7b80\u4fbf \u5ba2 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=10122","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-14T11:29:28+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"13 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=10122","url":"https:\/\/longmai-nt.com\/?page_id=10122","name":"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=10122#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=10122#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","datePublished":"2026-08-08T10:50:26+00:00","dateModified":"2026-11-14T11:29:28+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=10122#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=10122"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=10122#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/VAM%E5%B0%8A%E7%9D%BF%E5%85%A8%E6%95%88-II02.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=10122#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3","item":"https:\/\/longmai-nt.com\/?page_id=2297"},{"@type":"ListItem","position":3,"name":"\u9f99\u6e56\u5149\u5e74-\u674e\u5973\u58eb\u522b\u5885\u6696\u901a\u65b9\u6848\u5168\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10122"}],"version-history":[{"count":5,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10122\/revisions"}],"predecessor-version":[{"id":20555,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10122\/revisions\/20555"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2297"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}