{"id":10237,"date":"2026-08-10T00:31:03","date_gmt":"2026-08-09T16:31:03","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=10237"},"modified":"2026-10-09T15:38:19","modified_gmt":"2026-10-09T07:38:19","slug":"%e6%9f%af%e8%80%81%e5%b8%88-%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83-%e5%9c%b0%e6%9a%96-%e5%87%80%e6%b0%b4-%e6%96%b0%e9%a3%8e%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=10237","title":{"rendered":"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848"},"content":{"rendered":"\n<script type=\"application\/ld+json\" id=\"lm-10237-jsonld\">\n{\n \"@context\": \"https:\/\/schema.org\",\n \"@graph\": [\n  {\n   \"@type\": \"Article\",\n   \"@id\": \"https:\/\/longmai-nt.com\/?page_id=10237#article\",\n   \"headline\": \"\u67ef\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u51c0\u6c34+\u65b0\u98ce\u56db\u4ef6\u5957\u65b9\u6848\u00b7\u8212\u4eab140+\u535a\u4e16G6100W+\u963f\u5c14\u838e\u5a1c+\u4e91\u51c0\u4e8c\u4ee3250\",\n   \"description\": \"\u6210\u90fd\u67ef\u8001\u5e08\u4f4f\u5b85\u56db\u4ef6\u5957\u65b9\u6848\uff1a\u4e2d\u592e\u7a7a\u8c03\u8212\u4eab140\u5355\u98ce\u6247\u5916\u673aRAS-140HRNAQ+5\u53f0\u5185\u673a\uff1b\u5730\u6696\u535a\u4e16G6100W 24kW\u9505\u7089\uff1b\u51c0\u6c34\u963f\u5c14\u838e\u5a1c\u524d\u7f6e+\u53a8\u4e0b+\u4e2d\u592e\u8f6f\u6c34\uff1b\u65b0\u98ce\u4e91\u51c0\u4e8c\u4ee3250m\u00b3\/h\u65b0\u98ce\u3002\u542b\u8fde\u63a5\u7387\u5408\u89c4\u8bf4\u660e\u4e0e\u9009\u578b\u903b\u8f91\u3002\",\n   \"author\": {\n    \"@type\": \"Person\",\n    \"@id\": \"https:\/\/longmai-nt.com\/#miaoyi-founder\",\n    \"name\": \"\u7f2a\u5f02\"\n   },\n   \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\"\n   },\n   \"datePublished\": \"2026-08-09\"\n  },\n  {\n   \"@type\": \"FAQPage\",\n   \"mainEntity\": [\n    {\n     \"@type\": \"Question\",\n     \"name\": \"\u8212\u4eab140\u5916\u673a\u62d65\u53f0\u5185\u673a\u8fde\u63a5\u7387128.6%\u662f\u5426\u5408\u89c4\uff1f\",\n     \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"\u5408\u89c4\u3002\u8212\u4eab\u5355\u98ce\u6247RAS-140HRNAQ\u5236\u51b714.0kW\uff0c5\u53f0\u5185\u673a\u603b\u989d\u5b9a18.0kW\uff0c\u8fde\u63a5\u7387128.6%\uff0c\u843d\u5728\u7eaf\u6c1f\u7cfb\u7edf50-130%\u5408\u89c4\u533a\uff08\u7406\u60f390-110%\uff0c\u8d85110%\u65f6\u5236\u51b7\u5236\u70ed\u5747\u6709\u529b\uff09\u3002128.6%\u5728\u5b89\u5168\u8303\u56f4\u5185\u3002\"\n     }\n    },\n    {\n     \"@type\": \"Question\",\n     \"name\": \"\u5730\u6696\u9762\u79ef\u600e\u4e48\u7b97\u7684\uff1f\",\n     \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"\u5730\u6696\u9762\u79ef110.5\u33a1\uff0c\u6309\u4e3b\u5367+\u6b21\u5367+\u4e66\u623f+\u5ba2\u9910\u5385\u9633\u53f0\u7b49\u5b9e\u9645\u94fa\u8bbe\u533a\u57df\u6838\u7b97\uff1b\u6309\u8282\u80fd\u5730\u6696\u5957\u9910 169 \u5143\/\u33a1\uff08\u6309\u94fa\u8bbe\u9762\u79ef\u8ba1\uff09\u542b\u5b89\u88c5\uff0c\u535a\u4e16G6100W 24kW\u5e26\u8be5\u9762\u79ef\u5730\u6696\u529f\u7387\u8db3\u591f\u3002\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\u3002\"\n     }\n    },\n    {\n     \"@type\": \"Question\",\n     \"name\": \"\u963f\u5c14\u838e\u5a1c\u51c0\u6c34\u5668\u600e\u4e48\u9009\u578b\uff1f\",\n     \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"\u524d\u7f6e\u8fc7\u6ee4\u5668model X-A\uff1a\u8fc7\u6ee4\u5e02\u653f\u7ba1\u7f51\u6ce5\u6c99\u94c1\u9508\uff0c\u624b\u52a8\u53cd\u51b2\u6d17\uff1b\u53a8\u4e0b\u7eaf\u6c34\u673aE75\uff1aRO\u53cd\u6e17\u900f\u76f4\u996e\uff0c\u51fa\u6c34\u91cf75G\uff0c\u9002\u5408\u53a8\u623f\u70f9\u996a+\u76f4\u996e\uff1b\u4e2d\u592e\u8f6f\u6c34\u673aR18\uff1a2\u5428\/\u5c0f\u65f6\uff0c\u53bb\u9664\u9499\u9541\u79bb\u5b50\uff0c\u9632\u7ed3\u57a2\u4fdd\u62a4\u70ed\u6c34\u5668\u548c\u5730\u6696\u3002\u4e09\u4e2a\u7ec4\u5408\u8986\u76d6\u5168\u5c4b\u51c0\u6c34\u3002\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\u3002\"\n     }\n    },\n    {\n     \"@type\": \"Question\",\n     \"name\": \"\u535a\u4e16G6100W 24kW\u5e26\u5730\u6696\u591f\u4e0d\u591f\uff1f\",\n     \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"\u535a\u4e16G6100W 24kW\u4e3a\u5e38\u89c4\u7cfb\u7edf\u7089\uff0c\u529f\u7387\u9002\u5408120-180\u33a1\u5730\u6696\uff08\u67ef\u8001\u5e08110.5\u33a1\uff09\u3002\u7cfb\u7edf\u7089\u5e26\u6c34\u7bb1\u7f13\u51b2\uff0c\u9002\u5408\u5730\u6696\u957f\u5468\u671f\u4f4e\u6e29\u8fd0\u884c\u3002\u5b89\u88c5\u8d39\u4ee5\u73b0\u573a\u62a5\u4ef7\u4e3a\u51c6\u3002\"\n     }\n    },\n    {\n     \"@type\": \"Question\",\n     \"name\": \"\u65b0\u98ce\u4e91\u51c0\u4e8c\u4ee3250m\u00b3\/h\u662f\u4ec0\u4e48\u4ef7\u683c\uff1f\",\n     \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"\u65b0\u98ce\u4e91\u51c0\u4e8c\u4ee3KPI-2521Q3A\/F(250m\u00b3\/h)\u4e3a\u8be5\u6237\u578b\u65b0\u98ce\u914d\u7f6e\u673a\u578b\uff0c\u98ce\u91cf250m\u00b3\/h\uff0c\u5b89\u88c5\u8d39\u5df2\u542b\u3002\u5177\u4f53\u8bbe\u5907\u4ef7\u4e0e\u5b89\u88c5\u8d39\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u62a5\u4ef7\u4e3a\u51c6\uff0c\u4e0d\u5728\u7f51\u9875\u516c\u793a\u3002\"\n     }\n    },\n    {\n     \"@type\": \"Question\",\n     \"name\": \"\u56db\u5757\u603b\u4ef7\u591a\u5c11\uff1f\",\n     \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"\u56db\u5957\u7cfb\u7edf\u5408\u8ba1\u533a\u95f4\u7ea68~9\u4e07\u5143\uff08\u542b\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u9505\u7089\u3001\u5168\u5c4b\u51c0\u6c34\u3001\u65b0\u98ce\uff1b\u51c0\u6c34\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\uff1b\u5177\u4f53\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\uff09\u3002\"\n     }\n    }\n   ]\n  }\n ]\n}\n<\/script>\n\n<style>\n.entry-content, .entry-content * { box-sizing: border-box; margin: 0; padding: 0; }\n\n.entry-content { font-family: -apple-system, BlinkMacSystemFont, \"PingFang SC\", \"Microsoft YaHei\", \"Helvetica Neue\", Arial, sans-serif; color: #333; line-height: 1.8; }\n.section[id] { scroll-margin-top: 80px; }\nimg { max-width: 100%; height: auto; display: block; }\n.entry-content .container { max-width: 1100px; margin: 0 auto; padding: 0 20px; }\n\n.hero { background: url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-07.png') center\/cover no-repeat; color: #fff; padding: 60px 0 50px; position: relative; overflow: hidden; text-align: center; }\n.hero::before { content: ''; position: absolute; top: 0; left: 0; right: 0; bottom: 0; background: transparent; z-index: 0; }\n.hero .container { position: relative; z-index: 1; }\n.hero h1 { font-size: 1.9rem; font-weight: 700; margin-bottom: 8px; letter-spacing: 2px; text-shadow: 0 2px 14px rgba(0,0,0,0.75); }\n.hero .subtitle { font-size: 1.05rem; opacity: 0.95; margin-bottom: 24px; text-shadow: 0 1px 8px rgba(0,0,0,0.6); }\n.hero .cta-row { margin-top: 18px; display: flex; gap: 12px; justify-content: center; flex-wrap: wrap; }\n.hero .cta { display: inline-block; background: #1a3c6e; color: #fff; padding: 10px 28px; border-radius: 24px; font-weight: 700; text-decoration: none; transition: all 0.2s; box-shadow: 0 4px 12px rgba(26,60,110,0.25); }\n.hero .cta:hover { background: #c00; transform: scale(1.03); box-shadow: 0 6px 16px rgba(204,0,0,0.3); }\n.hero .cta.alt { background: transparent; color: #1a3c6e; border: 2px solid #1a3c6e; }\n.hero .meta { margin-top: 14px; font-size: 0.85rem; color: #1a3c6e; opacity: 0.85; text-shadow: 0 1px 3px rgba(255,255,255,0.7); }\n\n.section-block { padding: 50px 0; background: #fff; }\n.section-block:nth-child(even) { background: #fafbfc; }\n.section-title { font-size: 1.5rem; color: #1a3c6e; margin-bottom: 6px; font-weight: 700; border-left: 5px solid #c00; padding-left: 12px; }\n.section-desc { color: #666; margin-bottom: 18px; font-size: 0.92rem; }\n\ntable { width: 100%; border-collapse: collapse; margin: 14px 0; background: #fff; border-radius: 8px; overflow: hidden; box-shadow: 0 1px 6px rgba(0,0,0,0.05); }\nth, td { padding: 12px 14px; border-bottom: 1px solid #eee; text-align: left; vertical-align: top; font-size: 0.9rem; }\nth { background: #1a3c6e; color: #fff; font-weight: 600; }\ntr:nth-child(even) td { background: #f7f9fc; }\n\ndetails.info-card, details.faq-item, details.evidence { background: #fff; border: 1px solid #e0e0e0; border-radius: 10px; margin: 10px 0; padding: 0; overflow: hidden; }\ndetails.faq-item summary, details.evidence summary { padding: 14px 18px; cursor: pointer; font-weight: 700; color: #1a3c6e; font-size: 0.95rem; position: relative; list-style: none; }\nsummary::-webkit-details-marker { display: none; }\ndetails.faq-item summary::after, details.evidence summary::after { content: '\u25be'; position: absolute; right: 16px; top: 50%; transform: translateY(-50%); transition: transform 0.3s; }\ndetails[open] summary::after { transform: translateY(-50%) rotate(180deg); }\n.faq-a, .ev-body { padding: 0 18px 16px; font-size: 0.88rem; color: #555; line-height: 1.8; }\n\n.flip-toggle { position: absolute; inset: 0; width: 100%; height: 100%; margin: 0; opacity: 0; cursor: pointer; z-index: 5; }\n.product-card-wrapper { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 16px; margin: 18px 0; }\n.product-flip { position: relative; perspective: 1000px; }\n.product-flip .flip-toggle:checked ~ .product-flip-inner { transform: rotateY(180deg); }\n.product-flip-inner { position: relative; width: 100%; min-height: 240px; transition: transform 0.6s; transform-style: preserve-3d; cursor: pointer; }\n.product-front, .product-back { position: absolute; top: 0; left: 0; width: 100%; min-height: 240px; backface-visibility: hidden; border-radius: 14px; padding: 20px; box-sizing: border-box; }\n.product-front { background: linear-gradient(135deg, #fff 0%, #f0f4ff 100%); border: 1px solid #dfe7f3; display: flex; flex-direction: column; justify-content: center; align-items: center; text-align: center; }\n.product-front::after { content: '\ud83d\udc46 \u70b9\u51fb\u7ffb\u8f6c'; position: absolute; bottom: 8px; right: 10px; font-size: 0.7rem; color: #999; }\n.product-back { background: linear-gradient(135deg, #1a3c6e 0%, #2a5a9e 100%); color: #fff; transform: rotateY(180deg); }\n.product-back .p-desc { font-size: 0.85rem; line-height: 1.9; }\n.product-back::after { content: '\ud83d\udc46 \u70b9\u51fb\u7ffb\u56de'; position: absolute; bottom: 8px; right: 10px; font-size: 0.7rem; color: rgba(255,255,255,0.7); }\n.p-icon { font-size: 3rem; margin-bottom: 12px; }\n.p-name { font-weight: 700; color: #1a3c6e; font-size: 1.05rem; margin-bottom: 4px; }\n.p-model { color: #555; font-size: 0.85rem; font-family: monospace; margin-bottom: 10px; }\n.p-tag { display: inline-block; background: #ffd54f; color: #1a3c6e; padding: 2px 10px; border-radius: 10px; font-size: 11.5px; font-weight: 700; }\n\n.plan-tag { display: inline-block; background: #1a3c6e; color: #fff; font-size: 0.85rem; padding: 4px 14px; border-radius: 14px; margin-bottom: 12px; font-weight: 600; }\n.plan-tag.recommend { background: #c00; }\n.plan-tag.water { background: #0a7e8c; }\n.plan-tag.boiler { background: #b05a00; }\n\n.price-box { background: linear-gradient(135deg, #fff8f0 0%, #fffbe6 100%); border: 2px solid #ffd54f; border-radius: 12px; padding: 16px 20px; margin: 14px 0; }\n.price-box .final { font-size: 1.05rem; font-weight: 700; color: #c00; margin-bottom: 8px; }\n.price-box .note { font-size: 0.82rem; color: #666; line-height: 1.7; }\n.shot-tag { display: inline-block; background: #1a3c6e; color: #ffd54f; padding: 4px 12px; border-radius: 12px; font-size: 0.78rem; margin-top: 8px; font-weight: 600; }\n\n.feature-list { list-style: none; padding: 0; margin: 14px 0; }\n.feature-list li { padding: 8px 0 8px 24px; position: relative; font-size: 0.92rem; color: #333; }\n.feature-list li::before { content: '\u2713'; position: absolute; left: 0; color: #52c41a; font-weight: 700; font-size: 1.1rem; }\n\n.lm-nav { background: #fff; border-bottom: 2px solid #1a3c6e; padding: 14px 0; position: sticky; top: 0; z-index: 100; box-shadow: 0 2px 10px rgba(0,0,0,0.05); }\n.nav-list { list-style: none; display: flex; gap: 8px; max-width: 1100px; margin: 0 auto; padding: 0 20px; flex-wrap: wrap; }\n.nav-list li a { display: inline-block; padding: 6px 14px; background: #f0f4ff; color: #1a3c6e; text-decoration: none; border-radius: 16px; font-size: 0.85rem; }\n.nav-list li a:hover { background: #1a3c6e; color: #fff; }\n\n.link-card { display: block; background: #fff; border: 1px solid #e3e8f0; border-left: 4px solid #1a3c6e; border-radius: 10px; padding: 16px 18px; text-decoration: none; color: #333; transition: all 0.25s; }\n.link-card:hover { box-shadow: 0 4px 16px rgba(0,0,0,0.1); transform: translateY(-2px); border-left-color: #c00; }\n.link-card .title { display: block; font-weight: 700; color: #1a3c6e; font-size: 0.92rem; margin-bottom: 4px; }\n.link-card .desc { display: block; font-size: 0.8rem; color: #777; }\n\n.lm-store-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 16px; margin: 14px 0; }\n.lm-store { background: #fff; border-radius: 12px; overflow: hidden; box-shadow: 0 2px 10px rgba(0,0,0,0.06); }\n.lm-store img { width: 100%; height: 160px; object-fit: cover; }\n.lm-store .lm-st-name { font-weight: 700; color: #1a3c6e; padding: 10px 14px 2px; }\n.lm-store div { padding: 0 14px 6px; font-size: 0.84rem; color: #555; }\n.lm-store a { color: #1a3c6e; text-decoration: none; font-weight: 700; }\n\n.cta-box { background: linear-gradient(135deg, #1a3c6e 0%, #c00 100%); color: #fff; border-radius: 16px; padding: 36px 30px; text-align: center; margin: 30px 0; }\n.cta-box h3 { font-size: 1.3rem; margin-bottom: 10px; }\n.cta-box p { font-size: 0.9rem; opacity: 0.92; margin-bottom: 6px; }\n.cta-box a.tel { color: #ffd54f; font-size: 1.15rem; font-weight: 700; text-decoration: none; }\n.cta-box .btn { display: inline-block; margin-top: 14px; background: #ffd54f; color: #1a3c6e; font-weight: 700; padding: 10px 32px; border-radius: 24px; text-decoration: none; font-size: 0.95rem; }\n.cta-box .scope { font-size: 0.78rem; opacity: 0.75; margin-top: 12px; }\n\n.footer { background: #13294b; color: #bcd; text-align: center; padding: 36px 20px; }\n.footer h3 { color: #fff; font-size: 1.05rem; margin-bottom: 8px; }\n.footer p { font-size: 0.82rem; margin-bottom: 4px; }\n.footer .phone a { color: #ffd54f; font-size: 1rem; text-decoration: none; font-weight: 700; }\n\n.warn { background: #fff4f4; border: 1px solid #ffccc0; border-radius: 10px; padding: 12px 16px; font-size: 0.84rem; color: #a33; margin: 10px 0; }\n.warn.info { background: #fffbe6; border-color: #ffd54f; color: #7a5a00; }\n<\/style>\n\n<header class=\"hero\">\n  <div class=\"container\">\n    <h2>\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848<\/h2>\n    <p class=\"subtitle\">\u8212\u4eab140\u5355\u98ce\u6247\u5916\u673a \u00b7 \u4e94\u53f0\u5185\u673a \u00b7 \u535a\u4e16G6100W 24kW \u00b7 \u963f\u5c14\u838e\u5a1c\u51c0\u6c34\u4e09\u4ef6\u5957 \u00b7 \u4e91\u51c0\u4e8c\u4ee3250m\u00b3\/h<\/p>\n    <p><\/p>\n    <div class=\"cta-row\">\n      <a class=\"cta\" href=\"tel:02886131795\">\u7535\u8bdd\u54a8\u8be2 028-86131795<\/a>\n      <a class=\"cta alt\" href=\"#s3\">\u67e5\u770b\u8be6\u7ec6\u62a5\u4ef7<\/a>\n    <\/div>\n    <p class=\"meta\">\u987e\u95ee\uff1a\u4f59\u7231\u82f1<\/p>\n  <\/div>\n<\/header>\n\n<section class=\"section-block\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">\u5ba2\u6237\u4fe1\u606f\u5361<\/h2>\n    <p class=\"section-desc\">\u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\u67e5\u770b\u623f\u95f4\u914d\u7f6e\u8be6\u60c5\uff08\u7edf\u4e00\u7ffb\u8f6c\uff0c\u7981\u533a\u5757\u7ffb\u8f6c\uff09<\/p>\n    <details class=\"info-card\">\n      <summary>\ud83d\udcc7 \u67ef\u8001\u5e08 \u00b7 \u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u51c0\u6c34<\/summary>\n      <div class=\"flip-ard-back\">\n        <div class=\"card-title\" style=\"color:#ffd54f;font-weight:700;margin-bottom:8px\">\ud83c\udfaf \u623f\u95f4\u914d\u7f6e\u4e0e\u8bbe\u5907\u65b9\u6848<\/div>\n        <ul>\n          <li><strong>\u4e3b\u5367<\/strong>\uff1a15.9\u33a1 \u00b7 \u8212\u4eab32\u5ba4\u5185\u673a\uff08RPIZ-32FSNAQD\/P\uff09<\/li>\n          <li><strong>\u6b21\u5367\u4e00<\/strong>\uff1a13.24\u33a1 \u00b7 \u8212\u4eab22\u5ba4\u5185\u673a\uff08RPIZ-22FSNAQD\/P\uff09<\/li>\n          <li><strong>\u6b21\u5367\u4e8c<\/strong>\uff1a9.5\u33a1 \u00b7 \u8212\u4eab18\u5ba4\u5185\u673a\uff08RPIZ-18FSNAQD\/P\uff09<\/li>\n          <li><strong>\u4e66\u623f<\/strong>\uff1a10.3\u33a1 \u00b7 \u8212\u4eab18\u5ba4\u5185\u673a\uff08RPIZ-18FSNAQD\/P\uff09<\/li>\n          <li><strong>\u5ba2\u9910\u5385+\u53a8\u623f+\u9633\u53f0<\/strong>\uff1a61.6\u33a1 \u00b7 \u8212\u4eab90\u5ba4\u5185\u673a\uff08RPIZ-90FSVNZQD\/P\uff0c\u51c0\u5316\u578b\uff09<\/li>\n          <li><strong>\u5916\u673a<\/strong>\uff1a\u8212\u4eab\u5355\u98ce\u6247 RAS-140HRNAQ\uff0814.0kW\uff0c5\u53f0\u5185\u673a\u603b\u989d\u5b9a18.0kW\uff09<\/li>\n          <li><strong>\u5730\u6696<\/strong>\uff1a\u535a\u4e16G6100W 24kW\u9505\u7089 + De32+De20\u7ba1\u5f84 + \u4f1f\u661f\u767d\u6676\u677f3cm + \u5206\u5ba4\u6e29\u63a7\u8054\u52a8<\/li>\n          <li><strong>\u51c0\u6c34<\/strong>\uff1a\u963f\u5c14\u838e\u5a1c\u524d\u7f6emodel X-A + \u53a8\u4e0bE75\u7eaf\u6c34\u673a + \u4e2d\u592e\u8f6f\u6c34\u673aR18\uff082T\uff09<\/li>\n          <li><strong>\u8fde\u63a5\u7387<\/strong>\uff1a18.0\/14.0 = 128.6%\uff08\u7eaf\u6c1f\u8212\u4eab\u5408\u89c4\u533a50-130%\uff0c\u2705\u5408\u89c4\uff09<\/li>\n        <\/ul>\n      <\/div>\n    <\/details>\n  <\/div>\n<\/section>\n\n<nav class=\"lm-nav\">\n<ul class=\"nav-list\">\n  <li><a href=\"#s1\">S1 \u76ee\u6807<\/a><\/li>\n  <li><a href=\"#s2\">S2 \u8bca\u65ad<\/a><\/li>\n  <li><a href=\"#s3\">S3 \u62a5\u4ef7<\/a><\/li>\n  <li><a href=\"#confirm\">\u5f85\u786e\u8ba4\u9879<\/a><\/li>\n  <li><a href=\"#evidence\">\u8bc1\u636e\u94fe<\/a><\/li>\n  <li><a href=\"#check\">AI\u6821\u9a8c<\/a><\/li>\n  <li><a href=\"#faq\">FAQ<\/a><\/li>\n  <li><a href=\"#material\">\u8f85\u6750<\/a><\/li>\n<\/ul>\n<\/nav>\n\n<section class=\"section-block\" id=\"s1\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n    <p class=\"section-desc\">\u628a&#8221;\u8212\u9002\u51b7\u6696\u00b7\u5b89\u5168\u5730\u6696\u00b7\u5168\u5c4b\u51c0\u6c34&#8221;\u7ffb\u8bd1\u6210\u53ef\u91cf\u5316\u76ee\u6807<\/p>\n    <table>\n      <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u76ee\u6807<\/th><th>\u9a8c\u6536\u65b9\u5f0f<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u5236\u51b7<\/td><td>\u5168\u5c4b5\u53f0\u5185\u673a\u00b7\u5404\u623f\u95f426\u2103\u7a33\u5b9a<\/td><td>\u51fa\u98ce\u6e29\u5ea6\u5b9e\u6d4b + \u5916\u673a\u8fd0\u884c\u7535\u6d41\u76d1\u6d4b<\/td><\/tr>\n        <tr><td>\u5236\u70ed<\/td><td>\u5730\u6696110.5\u33a1\u7a33\u5b9a20\u2103<\/td><td>\u5730\u9762\u6e29\u5ea6\u5b9e\u6d4b<\/td><\/tr>\n        <tr><td>\u8212\u9002\u5ea6<\/td><td>\u53d8\u9891\u8212\u4eab\u9759\u97f3\u8fd0\u884c\uff0c\u5ba4\u5185\u673a\u6700\u4f4e\u7ea622dB<\/td><td>\u5206\u8d1d\u4eea\u5b9e\u6d4b + \u5ba2\u6237\u4f53\u611f<\/td><\/tr>\n        <tr><td>\u51c0\u6c34<\/td><td>\u524d\u7f6e\u8fc7\u6ee4+RO\u76f4\u996e+\u8f6f\u6c34\u4fdd\u62a4\u5730\u6696\/\u70ed\u6c34\u5668<\/td><td>\u6c34\u8d28\u68c0\u6d4b + TDS\u503c\u5bf9\u6bd4<\/td><\/tr>\n        <tr><td>\u900f\u660e<\/td><td>\u4e09\u5757\u4ef7\u683c\u6e05\u6670<\/td><td>\u6b63\u5f0f\u62a5\u4ef7\u5355<\/td><\/tr>\n      <\/tbody>>\n    <\/table>\n  <\/div>\n<\/section>\n\n<section class=\"section-block\" id=\"s2\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">S2 \u00b7 \u9700\u6c42\u8bca\u65ad<\/h2>\n    <p class=\"section-desc\">\u623f\u95f4\u914d\u7f6e \u2192 \u8bca\u65ad\u7ed3\u8bba \u2192 \u89c4\u8303\u4f9d\u636e<\/p>\n    <table>\n      <thead><tr><th>\u5ba2\u6237\u914d\u7f6e<\/th><th>\u8bca\u65ad\u7ed3\u8bba<\/th><th>\u89c4\u8303 \/ \u6807\u51c6\u5f15\u7528<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>&#8220;\u4e3b\u536715.9\u33a1\u914d32\u8212\u4eab\u5ba4\u5185\u673a&#8221;<\/td><td>15.9\u33a1\u5367\u5ba4\u00b732\u578b=3.2kW\u8986\u76d6\u7ef0\u7ef0\u6709\u4f59\u00b7\u53d8\u9891\u8212\u4eab\u9759\u97f3<\/td><td>RPIZ-32FSNAQD\/P<\/td><\/tr>\n        <tr><td>&#8220;\u6b21\u5367\u4e0013.24\u33a1\u914d22\u8212\u4eab&#8221;<\/td><td>13.24\u33a1\u00b722\u578b=2.2kW\u7cbe\u51c6\u5339\u914d<\/td><td>RPIZ-22FSNAQD\/P<\/td><\/tr>\n        <tr><td>&#8220;\u6b21\u5367\u4e8c9.5\u33a1+\u4e66\u623f10.3\u33a1\u914d18\u8212\u4eab\u00d72&#8221;<\/td><td>\u5c0f\u7a7a\u95f4\u00b718\u578b=1.8kW\u7cbe\u51c6\u00b7\u53cc\u673a\u72ec\u7acb\u63a7\u6e29<\/td><td>RPIZ-18FSNAQD\/P\u00d72<\/td><\/tr>\n        <tr><td>&#8220;\u5ba2\u9910\u5385\u53a8\u623f\u9633\u53f061.6\u33a1\u914d90\u5ba4\u5185\u673a&#8221;<\/td><td>\u5927\u7a7a\u95f4\u00b790\u578b=9.0kW\uff08\u578b\u53f7\u547d\u540d\u89c4\u5219\uff1a90=9.0kW\uff09\uff0c\u8986\u76d661.6\u33a1\u5927\u7a7a\u95f4\u5408\u7406<\/td><td>RPIZ-90FSVNZQD\/P\uff08\u51c0\u5316\u578b\uff0c\u542b\u51c0\u5316\u529f\u80fd\uff09<\/td><\/tr>\n        <tr><td>&#8220;140\u8212\u4eab\u5355\u98ce\u6247\u62d65\u53f0&#8221;<\/td><td>\u5916\u673aRAS-140HRNAQ\u5236\u51b714.0kW\u00b7\u5185\u673a\u603b\u989d\u5b9a18.0kW\u00b7\u8fde\u63a5\u7387128.6%\uff0850-130%\u5408\u89c4\uff09<\/td><td> system.rules\uff08\u7eaf\u6c1f50-130%\uff09<\/td><\/tr>\n\n        <tr><td>&#8220;\u535a\u4e16G6100W 24kW\u5730\u6696&#8221;<\/td><td>24kW\u7cfb\u7edf\u7089\u9002\u5408120-180\u33a1\u5730\u6696\uff1b\u7cfb\u7edf\u7089\u5e26\u6c34\u7bb1\u7f13\u51b2\u9002\u5408\u957f\u5468\u671f\u4f4e\u6e29\u8fd0\u884c<\/td><td>\uff08\u535a\u4e16\u58c1\u6302\u7089\uff09<\/td><\/tr>\n        <tr><td>&#8220;\u963f\u5c14\u838e\u5a1c\u524d\u7f6e+\u7eaf\u6c34\u673a+\u8f6f\u6c34&#8221;<\/td><td>\u4e09\u4ef6\u5957\u8986\u76d6\u5168\u5c4b\u51c0\u6c34\uff1a\u8fc7\u6ee4+\u76f4\u996e+\u8f6f\u5316\u4fdd\u62a4\u5730\u6696\/\u70ed\u6c34\u5668<\/td><td>\uff08\u963f\u5c14\u838e\u5a1c\u51c0\u6c34\uff09<\/td><\/tr>\n      <\/tbody>>\n    <\/table>\n  <\/div>\n<\/section>\n\n<section class=\"section-block\" id=\"s3\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">S3 \u00b7 \u5206\u9879\u900f\u660e\u62a5\u4ef7<\/h2>\n    <p class=\"section-desc\">\u4e09\u5757\u72ec\u7acb\u7cfb\u7edf\uff1a\u4e2d\u592e\u7a7a\u8c03 \/ \u5730\u6696\u9505\u7089 \/ \u5168\u5c4b\u51c0\u6c34\uff0c\u4e0e\u4ef7\u683c\u7c7b\u578b\u5404\u4e0d\u540c<\/p>\n\n    <span class=\"plan-tag recommend\">\u65b9\u6848\u4e00 \u00b7 \u4e2d\u592e\u7a7a\u8c03 \u00b7 \u8212\u4eab140\u4e94\u4ef6\u5957<\/span>\n    <h3 style=\"color:#c00;margin:6px 0 10px\">\ud83d\udccb \u8212\u4eab140\u5355\u98ce\u6247 + \u4e94\u53f0\u5185\u673a\uff0832\/22\/18\/18\/90\uff09<\/h3>\n    <div class=\"product-card-wrapper\">\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipA1\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\u2744\ufe0f<\/div><div class=\"p-name\">\u8212\u4eab\u5916\u673a 140<\/div><div class=\"p-model\">RAS-140HRNAQ<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">\u53d8\u9891\u8f6c\u5b50\u538b\u7f29\u673a<br>\u5236\u51b714.0kW \/ \u5236\u70ed16.0kW<br>APF 5.8\uff08\u4e00\u7ea7\u80fd\u6548\uff09<br>\u5355\u98ce\u6247\u00b754dB\u00b7770\u00d7980\u00d7360mm<br>\u62d65\u53f0\u5185\u673a\uff0818.0kW\uff09<\/div><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipA2\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83d\udecf\ufe0f<\/div><div class=\"p-name\">\u8212\u4eab\u5ba4\u5185\u673a 32\/22\/18\/90<\/div><div class=\"p-model\">RPIZ-FSNAQD\/P<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">DC\u8584\u578b\u6807\u51c6\u98ce\u7ba1\u673a<br>\u9759\u97f3\u7ea622dB<br>\u4e3b\u536732+\u6b21\u536722+\u6b21\u536718+\u4e66\u623f18+\u5ba2\u9910\u538590<br>\u8584\u578b\u5b89\u88c5\u7701\u5c42\u9ad8<\/div><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <table>\n      <thead><tr><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u8212\u4eab\u5916\u673a<\/td><td>RAS-140HRNAQ<\/td><td>1<\/td><\/tr>\n        <tr><td>\u8212\u4eab\u5185\u673a<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1<\/td><\/tr>\n        <tr><td>\u8212\u4eab\u5185\u673a<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1<\/td><\/tr>\n        <tr><td>\u8212\u4eab\u5185\u673a<\/td><td>RPIZ-18FSNAQD\/P<\/td><td>2<\/td><\/tr>\n        <tr><td>\u8212\u4eab\u5185\u673a90\uff08\u51c0\u5316\u578b\uff09<\/td><td>RPIZ-90FSVNZQD\/P<\/td><td>1<\/td><\/tr>\n        <tr><td colspan=\"3\"><strong>\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td><\/tr>\n        <tr><td colspan=\"3\">\u5b89\u88c5\u8d39\uff1a\u6c1f\u7cfb\u7edf\u5185\u673a5\u53f0\u3001\u5916\u673a1\u53f0\uff0c\u542b\u5b89\u88c5\uff08\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\uff09<\/td><\/tr>\n        \n      <\/tbody>>\n    <\/table>\n    <div class=\"price-box\">\n      <div class=\"final\">\u65b9\u6848\u4e00\uff08\u7a7a\u8c03\uff09\u603b\u4ef7\u533a\u95f4 \u2248 3.0~3.5 \u4e07\u5143\uff08\u542b\u8bbe\u5907\u4e0e\u5b89\u88c5\uff0c\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\uff09<\/div>\n      <div class=\"note\">\u5177\u4f53\u8bbe\u5907\u914d\u7f6e\u4e0e\u6210\u4ea4\u4ef7\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u51fa\u5177\u7684\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\u3002<\/div>\n\n    <\/div>\n\n  \n    <span class=\"plan-tag boiler\">\u65b9\u6848\u4e8c \u00b7 \u5730\u6696\u9505\u7089\u7cfb\u7edf<\/span>\n    <h3 style=\"color:#b05a00;margin:6px 0 10px\">\ud83d\udccb \u5730\u6696 + \u535a\u4e16G6100W 24kW\u9505\u7089<\/h3>\n    <div class=\"product-card-wrapper\">\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipB1\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83d\udd25<\/div><div class=\"p-name\">\u535a\u4e16G6100W 24kW<\/div><div class=\"p-model\">L1P27-G6100W 24 CBG<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">\u56fd\u4ea7\u5e38\u89c4\u7cfb\u7edf\u7089<br>24kW\u9002\u5408120-180\u33a1\u5730\u6696<br>\u7cfb\u7edf\u7089\u5e26\u6c34\u7bb1\u7f13\u51b2<br>\u9002\u5408\u5730\u6696\u4f4e\u6e29\u957f\u5468\u671f\u8fd0\u884c<\/div><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipB2\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83c\udf21\ufe0f<\/div><div class=\"p-name\">\u5730\u6696\u7cfb\u7edf<\/div><div class=\"p-model\">De32+De20 \u00b7 \u4f1f\u661f\u767d\u6676\u677f3cm<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">De32+De20\u7ba1\u5f84\u7ec4\u5408<br>\u4f1f\u661f\u767d\u6676\u677f3cm\u4fdd\u6e29<br>\u56de\u586b\u7c73\u77f3+425\u6c34\u6ce5<br>\u5206\u5ba4\u6e29\u63a7+\u8054\u52a8\u63a7\u5236<br>\u542b\u8bbe\u8ba1\/\u65bd\u5de5\/\u76d1\u7406\/\u8054\u4fdd<\/div><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <table>\n      <thead><tr><th>\u8bbe\u5907\/\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u535a\u4e16G6100W 24kW<\/td><td>L1P27-G6100W 24 CBG<\/td><td>1<\/td><\/tr>\n        <tr><td>\u535a\u4e16\u5b89\u88c5\u8d39<\/td><td>\u2014<\/td><td>1<\/td><\/tr>\n        <tr><td>\u5730\u6696\uff08\u7ba1\u5f84De32+De20\uff09<\/td><td>\u8282\u80fd\u5730\u6696\u5957\u9910 169 \u5143\/\u33a1\uff08\u6309\u94fa\u8bbe\u9762\u79ef\u8ba1\uff09<\/td><td>110.5\u33a1<\/td><\/tr>\n      <\/tbody>>\n    <\/table>\ntbody\n    \n    <div class=\"price-box\">\n      <div class=\"final\">\u65b9\u6848\u4e8c\uff08\u5730\u6696+\u9505\u7089\uff09\u603b\u4ef7\u533a\u95f4 \u2248 2.4~2.9 \u4e07\u5143\uff08\u542b\u8bbe\u5907\u4e0e\u5b89\u88c5\uff09<\/div>\n      <div class=\"note\">\u5730\u6696\u7ea6110.5\u33a1\uff0c\u6309\u8282\u80fd\u5730\u6696\u5957\u9910 169 \u5143\/\u33a1\uff08\u6309\u94fa\u8bbe\u9762\u79ef\u8ba1\uff09\u6838\u7b97\u3001\u542b\u5b89\u88c5\uff1b\u535a\u4e16G6100W 24kW\u9505\u7089\u9002\u914d\u8be5\u9762\u79ef\u3002\u5177\u4f53\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\u3002<\/div>\n      \n    <\/div>\n\n\n    <span class=\"plan-tag water\">\u65b9\u6848\u4e09 \u00b7 \u5168\u5c4b\u51c0\u6c34\u4e09\u4ef6\u5957<\/span>\n    <h3 style=\"color:#0a7e8c;margin:6px 0 10px\">\ud83d\udccb \u963f\u5c14\u838e\u5a1c\u524d\u7f6e + \u7eaf\u6c34\u673a + \u8f6f\u6c34\u673a<\/h3>\n    <div class=\"product-card-wrapper\">\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipC1\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83d\udca7<\/div><div class=\"p-name\">\u524d\u7f6e\u8fc7\u6ee4\u5668 model X-A<\/div><div class=\"p-model\">\u963f\u5c14\u838e\u5a1c<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">\u8fc7\u6ee4\u5e02\u653f\u7ba1\u7f51\u6ce5\u6c99\u94c1\u9508<br>\u624b\u52a8\u53cd\u51b2\u6d17<br>\u4fdd\u62a4\u540e\u7aef\u51c0\u6c34\u8bbe\u5907<br>\u5b89\u88c5\u4e8e\u603b\u6c34\u9600\u540e<\/div><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipC2\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83d\udeb0<\/div><div class=\"p-name\">\u53a8\u4e0b\u7eaf\u6c34\u673a E75<\/div><div class=\"p-model\">\u963f\u5c14\u838e\u5a1c<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">RO\u53cd\u6e17\u900f\u76f4\u996e<br>\u51fa\u6c34\u91cf75G<br>\u9002\u5408\u53a8\u623f\u70f9\u996a+\u76f4\u996e<br>\u53a8\u4e0b\u5b89\u88c5\u8282\u7701\u7a7a\u95f4<\/div><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipC3\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83d\udec1<\/div><div class=\"p-name\">\u4e2d\u592e\u8f6f\u6c34\u673a R18\uff082T\uff09<\/div><div class=\"p-model\">\u963f\u5c14\u838e\u5a1c<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">2\u5428\/\u5c0f\u65f6\u8f6f\u5316<br>\u53bb\u9664\u9499\u9541\u79bb\u5b50\u9632\u7ed3\u57a2<br>\u4fdd\u62a4\u70ed\u6c34\u5668\u548c\u5730\u6696\u7ba1\u9053<br>\u63d0\u5347\u751f\u6d3b\u7528\u6c34\u8212\u9002\u5ea6<\/div><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <table>\n      <thead><tr><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u524d\u7f6e\u8fc7\u6ee4\u5668<\/td><td>\u963f\u5c14\u838e\u5a1c model X-A<\/td><td>1<\/td><\/tr>\n        <tr><td>\u53a8\u4e0b\u7eaf\u6c34\u673a<\/td><td>\u963f\u5c14\u838e\u5a1c E75<\/td><td>1<\/td><\/tr>\n        <tr><td>\u4e2d\u592e\u8f6f\u6c34\u673a<\/td><td>\u963f\u5c14\u838e\u5a1c R18\uff082T\uff09<\/td><td>1<\/td><\/tr>\n        <tr><td colspan=\"3\"><strong>\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td><\/tr>\n        <tr><td colspan=\"3\">\u26a0\ufe0f \u51c0\u6c34\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4<\/td><\/tr>\n      <\/tbody>>\n    <\/table>\n    <div class=\"price-box\">\n      <div class=\"final\">\u65b9\u6848\u4e09\uff08\u51c0\u6c34\uff09\u8bbe\u5907\u5408\u8ba1\u533a\u95f4 \u2248 1.3~1.6 \u4e07\u5143\uff08\u672a\u542b\u5b89\u88c5\u8d39\uff09<\/div>\n      <div class=\"note\">\u963f\u5c14\u838e\u5a1c\u524d\u7f6e+\u53a8\u4e0b+\u4e2d\u592e\u8f6f\u6c34\u4e09\u4ef6\u5957\uff0c\u578b\u53f7\u5df2\u7cbe\u786e\u5339\u914d\uff08model X-A \/ E75 \/ R18\uff09\uff1b\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\u3002<\/div>\n      \n    <\/div>\n\n\n    <span class=\"plan-tag water\">\u65b9\u6848\u56db \u00b7 \u65b0\u98ce\u7cfb\u7edf \u00b7 \u4e91\u51c0\u4e8c\u4ee3250m\u00b3\/h<\/span>\n<span class=\"plan-tag water\">\u65b9\u6848\u56db \u00b7 \u65b0\u98ce\u7cfb\u7edf \u00b7 \u4e91\u51c0\u4e8c\u4ee3250m\u00b3\/h<\/span>\n    <h3 style=\"color:#0a7e8c;margin:6px 0 10px\">\ud83d\udccb \u4e91\u51c0\u4e8c\u4ee3 250m\u00b3\/h \u65b0\u98ce\uff08KPI-2521Q3A\/F\uff09<\/h3>\n    <div class=\"product-card-wrapper\">\n      <div class=\"product-flip\">\n        <input type=\"checkbox\" class=\"flip-toggle\" id=\"lmflipD1\">\n        <div class=\"product-flip-inner\">\n          <div class=\"product-front\"><div class=\"p-icon\">\ud83c\udf2c\ufe0f<\/div><div class=\"p-name\">\u4e91\u51c0\u4e8c\u4ee3 \u65b0\u98ce 250<\/div><div class=\"p-model\">KPI-2521Q3A\/F<\/div><div class=\"p-tag\">\u793a\u610f\u56fe<\/div><\/div>\n          <div class=\"product-back\"><div class=\"p-desc\">250m\u00b3\/h\u5927\u98ce\u91cf<br>\u8fc7\u6ee4PM2.5+\u7532\u919b+CO\u2082<br>\u6301\u7eed\u5f15\u5165\u5ba4\u5916\u65b0\u9c9c\u7a7a\u6c14<br>\u4fdd\u62a4\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf<br>\u5b89\u88c5\u8d39\u5df2\u542b<\/div><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <table>\n      <thead><tr><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u4e91\u51c0\u4e8c\u4ee3\u65b0\u98ce<\/td><td>KPI-2521Q3A\/F(250m\u00b3\/h)<\/td><td>1<\/td><\/tr>\n        <tr><td colspan=\"3\">\u5b89\u88c5\u8d39\uff08\u5df2\u542b\uff09<\/td><\/tr>\n        <tr><td colspan=\"3\"><strong>\u5c0f\u8ba1<\/strong><\/td><\/tr><\/tbody>>\n    <\/table>\n    <div class=\"price-box\">\n      <div class=\"final\">\u65b9\u6848\u56db\uff08\u65b0\u98ce\uff09\u8bbe\u5907\u5408\u8ba1\u533a\u95f4 1.0~1.4 \u4e07\u5143\uff08\u542b\u5b89\u88c5\u8d39\uff09<\/div>\n      <div class=\"note\">\u65b0\u98ce\u4e91\u51c0\u4e8c\u4ee3KPI-2521Q3A\/F(250m\u00b3\/h)\uff0c\u98ce\u91cf250m\u00b3\/h\uff1b\u5b89\u88c5\u8d39\u5df2\u542b\u3002<\/div>\n    <\/div>\n\n\n    <div class=\"price-box\" style=\"background:linear-gradient(135deg,#e8f4ff 0%,#f0f8ff 100%);border-color:#1a3c6e;\">\n      <div class=\"final\" style=\"font-size:1.2rem;\">\u56db\u5957\u7cfb\u7edf\u5408\u8ba1\u533a\u95f4 \u2248 8~9 \u4e07\u5143\uff08\u51c0\u6c34\u5b89\u88c5\u8d39\u5f85\u73b0\u573a\u786e\u8ba4\uff09<\/div>\n      <div class=\"note\">\u56db\u5957\u7cfb\u7edf\u6309\u7a7a\u8c03\u3001\u5730\u6696\u9505\u7089\u3001\u5168\u5c4b\u51c0\u6c34\u3001\u65b0\u98ce\u5206\u9879\u62a5\u4ef7\uff0c\u5408\u8ba1\u533a\u95f4\u5982\u4e0a\u65b9\u6240\u793a\uff1b\u51c0\u6c34\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\u3002<\/div>\n      \n    <\/div>\n\n  <\/div>\n<\/section>\n\n\n<section class=\"section-block\" id=\"confirm\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">\u2705 \u67ef\u8001\u5e08\u5df2\u786e\u8ba4\u4e8b\u9879\uff08\u5747\u5df2\u56de\u586b\uff09<\/h2>\n\n    <details class=\"info-card\">\n      <summary>\u2705 \u5df2\u786e\u8ba4\u2460\uff1a\u5730\u6696\u9762\u79ef110.5\u33a1\uff08\u67ef\u8001\u5e08\u786e\u8ba4\uff09<\/summary>\n      <div class=\"flip-card-back\">\n        <div class=\"card-title\" style=\"color:#4caf50;font-weight:700;margin-bottom:8px\">\u5730\u6696\u9762\u79ef\u5df2\u786e\u8ba4<\/div>\n        <ul>\n          <li>\u5730\u6696\u94fa\u8bbe\u9762\u79ef110.5\u33a1\uff08\u67ef\u8001\u5e08\u76f4\u63a5\u786e\u8ba4\uff09<\/li>\n          <li>\u5730\u6696\u9762\u79ef\u7ea6110.5\u33a1\uff0c\u6309\u4e3b\u5367+\u6b21\u5367+\u4e66\u623f+\u5ba2\u9910\u5385\u9633\u53f0\u7b49\u5b9e\u9645\u94fa\u8bbe\u533a\u57df\u6838\u7b97\uff08\u542b\u5b89\u88c5\uff09\u3002<\/li>\n          <li>\u535a\u4e16G6100W 24kW\u9505\u7089\u5e26110.5\u33a1\u5730\u6696\u529f\u7387\u8db3\u591f<\/li>\n        <\/ul>\n      <\/div>\n    <\/details>\n\n    <details class=\"info-card\">\n      <summary>\u2705 \u5df2\u786e\u8ba4\u2461\uff1a\u51c0\u6c34\u5b89\u88c5\u8d39\u5f85\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4<\/summary>\n      <div class=\"flip-card-back\">\n        <div class=\"card-title\" style=\"color:#ffd54f;font-weight:700;margin-bottom:8px\">\u51c0\u6c34\u5b89\u88c5\u8d39\u8bf4\u660e<\/div>\n        <ul>\n          \n          <li>\u524d\u7f6e\u8fc7\u6ee4\u5668\uff1a\u901a\u5e38\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\uff08\u8fdb\u6c34\u4f4d\u7f6e\/\u6392\u6c34\uff09<\/li>\n          <li>\u53a8\u4e0b\u7eaf\u6c34\u673a\uff1a\u53a8\u4e0b\u7a7a\u95f4\/\u6c34\u8def\u6539\u9020<\/li>\n          <li>\u4e2d\u592e\u8f6f\u6c34\u673a\uff1a\u9700\u63a5\u8fdb\u51fa\u6c34\u7ba1+\u6392\u5e9f\u7ba1+\u7535\u6e90<\/li>\n          <li><strong>\u8bf7\u67ef\u8001\u5e08\u786e\u8ba4\u662f\u5426\u63a5\u53d7\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\u5b89\u88c5\u8d39<\/strong>\uff0c\u6216\u8981\u6c42\u6211\u65b9\u63d0\u524d\u4f30\u7b97<\/li>\n        <\/ul>\n      <\/div>\n    <\/details>\n\n    <details class=\"info-card\">\n      <summary>\u2705 \u5df2\u786e\u8ba4\u2462\uff1a\u65b0\u98ce\uff08\u67ef\u8001\u5e08\u786e\u8ba4\uff09<\/summary>\n      <div class=\"flip-card-back\">\n        <div class=\"card-title\" style=\"color:#ffd54f;font-weight:700;margin-bottom:8px\">\u65b0\u98ce\u8bf4\u660e<\/div>\n        <ul>\n          <li>\u4e91\u51c0\u4e8c\u4ee3KPI-2521Q3A\/F(250m\u00b3\/h)\uff1a\u98ce\u91cf250m\u00b3\/h\uff0c\u5b89\u88c5\u8d39\u5df2\u542b\u3002<\/li>\n        <\/ul>\n      <\/div>\n    <\/details>\n  <\/div>\n<\/section>\n\n\n<section class=\"section-block\" id=\"faq\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">FAQ \u00b7 \u5e38\u89c1\u95ee\u9898<\/h2>\n    <details class=\"faq-item\"><summary>\u8212\u4eab140\u5916\u673a\u62d65\u53f0\u5185\u673a\u8fde\u63a5\u7387128.6%\u662f\u5426\u5408\u89c4\uff1f<\/summary><div class=\"faq-a\">\u5408\u89c4\u3002\u8212\u4eab\u5355\u98ce\u6247RAS-140HRNAQ\u5236\u51b714.0kW\uff0c5\u53f0\u5185\u673a\u603b\u989d\u5b9a18.0kW\uff0c\u8fde\u63a5\u7387128.6%\uff0c\u843d\u5728\u7eaf\u6c1f\u7cfb\u7edf50-130%\u5408\u89c4\u533a\uff08\u7406\u60f390-110%\uff0c\u8d85110%\u65f6\u5236\u51b7\u5236\u70ed\u5747\u6709\u529b\uff09\u3002128.6%\u5728\u5b89\u5168\u8303\u56f4\u5185\u3002<\/div><\/details>\n    <details class=\"faq-item\"><summary>\u5730\u6696\u9762\u79ef\u600e\u4e48\u7b97\u7684\uff1f<\/summary><div class=\"faq-a\">\u5730\u6696\u9762\u79ef110.5\u33a1\uff0c\u6309\u4e3b\u5367+\u6b21\u5367+\u4e66\u623f+\u5ba2\u9910\u5385\u9633\u53f0\u7b49\u5b9e\u9645\u94fa\u8bbe\u533a\u57df\u6838\u7b97\uff1b\u6309\u8282\u80fd\u5730\u6696\u5957\u9910 169 \u5143\/\u33a1\uff08\u6309\u94fa\u8bbe\u9762\u79ef\u8ba1\uff09\u542b\u5b89\u88c5\uff0c\u535a\u4e16G6100W 24kW\u5e26\u8be5\u9762\u79ef\u5730\u6696\u529f\u7387\u8db3\u591f\u3002\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\u3002<\/div><\/details>\n\n    <details class=\"faq-item\"><summary>\u963f\u5c14\u838e\u5a1c\u51c0\u6c34\u5668\u600e\u4e48\u9009\u578b\uff1f<\/summary><div class=\"faq-a\">\u524d\u7f6e\u8fc7\u6ee4\u5668model X-A\uff1a\u8fc7\u6ee4\u5e02\u653f\u7ba1\u7f51\u6ce5\u6c99\u94c1\u9508\uff0c\u624b\u52a8\u53cd\u51b2\u6d17\uff1b\u53a8\u4e0b\u7eaf\u6c34\u673aE75\uff1aRO\u53cd\u6e17\u900f\u76f4\u996e\uff0c\u51fa\u6c34\u91cf75G\uff0c\u9002\u5408\u53a8\u623f\u70f9\u996a+\u76f4\u996e\uff1b\u4e2d\u592e\u8f6f\u6c34\u673aR18\uff1a2\u5428\/\u5c0f\u65f6\uff0c\u53bb\u9664\u9499\u9541\u79bb\u5b50\uff0c\u9632\u7ed3\u57a2\u4fdd\u62a4\u70ed\u6c34\u5668\u548c\u5730\u6696\u3002\u4e09\u4e2a\u7ec4\u5408\u8986\u76d6\u5168\u5c4b\u51c0\u6c34\u3002\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\u3002<\/div><\/details>\n    <details class=\"faq-item\"><summary>\u535a\u4e16G6100W 24kW\u5e26\u5730\u6696\u591f\u4e0d\u591f\uff1f<\/summary><div class=\"faq-a\">\u535a\u4e16G6100W 24kW\u4e3a\u5e38\u89c4\u7cfb\u7edf\u7089\uff0c\u529f\u7387\u9002\u5408120-180\u33a1\u5730\u6696\uff08\u67ef\u8001\u5e08110.5\u33a1\uff09\u3002\u7cfb\u7edf\u7089\u5e26\u6c34\u7bb1\u7f13\u51b2\uff0c\u9002\u5408\u5730\u6696\u957f\u5468\u671f\u4f4e\u6e29\u8fd0\u884c\u3002\u5b89\u88c5\u8d39\u4ee5\u73b0\u573a\u62a5\u4ef7\u4e3a\u51c6\u3002<\/div><\/details>\n    <details class=\"faq-item\"><summary>\u65b0\u98ce\u4e91\u51c0\u4e8c\u4ee3250m\u00b3\/h\u662f\u4ec0\u4e48\u4ef7\u683c\uff1f<\/summary><div class=\"faq-a\">\u65b0\u98ce\u4e91\u51c0\u4e8c\u4ee3KPI-2521Q3A\/F(250m\u00b3\/h)\u4e3a\u8be5\u6237\u578b\u65b0\u98ce\u914d\u7f6e\u673a\u578b\uff0c\u98ce\u91cf250m\u00b3\/h\uff0c\u5b89\u88c5\u8d39\u5df2\u542b\u3002\u5177\u4f53\u8bbe\u5907\u4ef7\u4e0e\u5b89\u88c5\u8d39\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u62a5\u4ef7\u4e3a\u51c6\uff0c\u4e0d\u5728\u7f51\u9875\u516c\u793a\u3002<\/div><\/details>\n    <details class=\"faq-item\"><summary>\u56db\u5757\u603b\u4ef7\u591a\u5c11\uff1f<\/summary><div class=\"faq-a\">\u56db\u5957\u7cfb\u7edf\u5408\u8ba1\u533a\u95f4\u7ea68~9\u4e07\u5143\uff08\u542b\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u9505\u7089\u3001\u5168\u5c4b\u51c0\u6c34\u3001\u65b0\u98ce\uff1b\u51c0\u6c34\u5b89\u88c5\u8d39\u9700\u73b0\u573a\u52d8\u5bdf\u540e\u786e\u8ba4\uff1b\u5177\u4f53\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u5355\u4e3a\u51c6\uff09\u3002<\/div><\/details>\n  <\/div>\n<\/section>\n\n\n<section class=\"section-block\" id=\"license\" style=\"background:#f8f9fa\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">\ud83c\udfc5 \u9f99\u8109\u6696\u901a\u00b7\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u8d44\u8d28<\/h2>\n    <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:16px;margin-top:16px\">\n      <div style=\"background:#fff;border-radius:10px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,.08)\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u4e66\" loading=\"lazy\" style=\"width:100%;display:block\">\n        <div style=\"padding:8px 12px;font-size:.85rem;color:#555;text-align:center\">\u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/div>\n      <\/div>\n      <div style=\"background:#fff;border-radius:10px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,.08)\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u8bc1\u4e66\" loading=\"lazy\" style=\"width:100%;display:block\">\n        <div style=\"padding:8px 12px;font-size:.85rem;color:#555;text-align:center\">\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\uff082026\uff09<\/div>\n      <\/div>\n      <div style=\"background:#fff;border-radius:10px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,.08)\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u7cfb\u7edf\u7279\u9080\u7ecf\u9500\u6388\u6743\u4e66\" loading=\"lazy\" style=\"width:100%;display:block\">\n        <div style=\"padding:8px 12px;font-size:.85rem;color:#555;text-align:center\">\u6c34\u7cfb\u7edf\u7279\u9080\u7ecf\u9500\u6388\u6743<\/div>\n      <\/div>\n      <div style=\"background:#fff;border-radius:10px;overflow:hidden;box-shadow:0 2px 10px rgba(0,0,0,.08)\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-gold.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u8bc1\u4e66\" loading=\"lazy\" style=\"width:100%;display:block\">\n        <div style=\"padding:8px 12px;font-size:.85rem;color:#555;text-align:center\">\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n\n<section class=\"section-block\" id=\"material\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355\uff08 \u9644\u8868\uff09<\/h2>\n    <p class=\"section-desc\">\u4e94\u5217\u683c\u5f0f\uff08\u7cfb\u7edf\/\u8f85\u6750\u540d\u79f0\/\u89c4\u683c\/\u6570\u91cf\/\u529f\u80fd\uff09\uff0c\u4e0d\u542b\u4ef7\u683c\uff1b\u54c1\u724c\u4e0e\u89c4\u683c\u4ee5\u539f\u6587\u4e3a\u51c6<\/p>\n    <table>\n      <thead><tr><th>\u7cfb\u7edf<\/th><th>\u8f85\u6750\u540d\u79f0<\/th><th>\u89c4\u683c\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u529f\u80fd<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td>\u4e2d\u592e\u7a7a\u8c03(\u9644\u8868A)<\/td><td>\u51b7\u5a92\u7ba1<\/td><td>\u7d2b\u94dc\u7ba1 \u03c66.35\/\u03c69.52\/\u03c612.7<\/td><td>\u6309\u5b9e<\/td><td>\u6c1f\u7cfb\u7edf\u51b7\u5a92\u5faa\u73af<\/td><\/tr>\n        <tr><td>\u4e2d\u592e\u7a7a\u8c03(\u9644\u8868A)<\/td><td>\u51b7\u51dd\u6c34\u7ba1<\/td><td>PVC-U de25\/de32<\/td><td>\u6309\u5b9e<\/td><td>\u6392\u6c34<\/td><\/tr>\n        <tr><td>\u72ec\u7acb\u5730\u6696(\u9644\u8868C)<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><td>De32+De20\uff08\u4e3b\u6b21\u7ba1\uff09<\/td><td>\u7ea6110.5\u33a1<\/td><td>\u8f90\u5c04\u91c7\u6696<\/td><\/tr>\n        <tr><td>\u72ec\u7acb\u5730\u6696(\u9644\u8868C)<\/td><td>\u4fdd\u6e29\u677f<\/td><td>\u4f1f\u661f\u767d\u6676\u677f 3cm<\/td><td>\u7ea6110.5\u33a1<\/td><td>\u9694\u70ed\u9632\u5411\u4e0b\u6563\u70ed<\/td><\/tr>\n        <tr><td>\u72ec\u7acb\u5730\u6696(\u9644\u8868C)<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u9ec4\u94dc\u591a\u8def<\/td><td>\u6309\u623f\u95f4\u6570<\/td><td>\u652f\u8def\u5206\u914d\/\u5e73\u8861<\/td><\/tr>\n        <tr><td>\u72ec\u7acb\u5730\u6696(\u9644\u8868C)<\/td><td>\u5206\u5ba4\u6e29\u63a7+\u8054\u52a8<\/td><td>\u65e0\u7ebf\/\u6709\u7ebf\u6e29\u63a7\u9762\u677f<\/td><td>\u6309\u533a\u57df<\/td><td>\u5206\u533a\u63a7\u6e29+\u9505\u7089\u8054\u52a8<\/td><\/tr>\n        <tr><td>\u51c0\u6c34<\/td><td>\u524d\u7f6e\u6ee4\u74f6\/RO\u819c\/\u6811\u8102<\/td><td>\u963f\u5c14\u838e\u5a1c\u539f\u88c5<\/td><td>\u54041\u5957<\/td><td>\u6309\u533a\u57df<\/td><td>\u5206\u533a\u63a7\u6e29+\u9505\u7089\u8054\u52a8<\/td><\/tr>\n        <tr><td>\u51c0\u6c34<\/td><td>\u524d\u7f6e\u6ee4\u74f6\/RO\u819c\/\u6811\u8102<\/td><td>\u963f\u5c14\u838e\u5a1c\u539f\u88c5<\/td><td>\u54041\u5957<\/td><td>\u8fc7\u6ee4\/\u51c0\u5316\/\u8f6f\u5316<\/td><\/tr>\n      <\/tbody>>\n    <\/table>\n    <p class=\"section-desc\">\u8bf4\u660e\uff1a\u8f85\u6750\u54c1\u724c\/\u89c4\u683c\u4ee5\u539f\u6587\u4e3a\u51c6\uff0c\u4e0d\u865a\u6784\u3002\u51c0\u6c34\u8f85\u6750\u4e3a\u8bbe\u5907\u81ea\u5e26\u914d\u4ef6\uff0c\u5b89\u88c5\u8f85\u6750\uff08\u7ba1\u8def\/\u9600\u95e8\uff09\u5f85\u73b0\u573a\u52d8\u5bdf\u786e\u8ba4\u3002<\/p>\n  <\/div>\n<\/section>\n\n\n<section class=\"section-block\">\n  <div class=\"container\">\n    <h2 class=\"section-title\">\u4e86\u89e3\u66f4\u591a<\/h2>\n    <p class=\"section-desc\">\u5ef6\u4f38\u9605\u8bfb\uff08\u5185\u94fe\u4ee5\u5b98\u7f51\u5b9e\u9645\u8def\u5f84\u4e3a\u51c6\uff0c\u53d1\u5e03\u524d\u6838\u5bf9 V3.1\u5185\u94fe\u4e09\u89d2\uff09<\/p>\n    <div class=\"case-grid\">\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\"><span class=\"title\">\u9f99\u8109\u6696\u901a\u00b7\u6848\u4f8b\u4e2d\u5fc3<\/span><span class=\"desc\">\u6210\u90fd\u540c\u9762\u79ef\u6bb5\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u5b9e\u666f\u6848\u4f8b<\/span><\/a>\n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\"><span class=\"title\">\u4ea7\u54c1\u4e2d\u5fc3\u00b7\u8212\u4eab\u7cfb\u5217<\/span><span class=\"desc\">EX\u8212\u4eab\u53d8\u9891\u591a\u8054\u673a\u53c2\u6570\u4e0e\u578b\u53f7\u8be6\u89e3<\/span><\/a>\n      \n      <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\"><span class=\"title\">\u7ad9\u70b9\u5730\u56fe<\/span><span class=\"desc\">\u65b9\u6848\/\u6848\u4f8b\/\u79d1\u666e\u5168\u91cf\u7d22\u5f15<\/span><\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n\n<section class=\"section-block\">\n  <div class=\"container\">\n    <div class=\"cta-box\">\n      <h3>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u786e\u8ba4\u5730\u6696\u9762\u79ef \u00b7 \u51fa\u6b63\u5f0f\u62a5\u4ef7\u5355<\/h3>\n      <p>\u9f99\u8109\u6696\u901a \u00b7 \u4f59\u7231\u82f1\u56e2\u961f \u00b7 \u6210\u90fd\u5357\/\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97<\/p>\n      <p><a class=\"tel\" href=\"tel:02886131795\">028-86131795<\/a> \uff5c <a class=\"tel\" href=\"tel:02865272586\">028-65272586<\/a><\/p>\n      <a class=\"btn\" href=\"tel:02886131795\">\u7acb\u5373\u9884\u7ea6\u52d8\u6d4b<\/a>\n      <p class=\"scope\">\u670d\u52a1\u8303\u56f4\uff1a\u9ad8\u65b0 \u00b7 \u53cc\u6d41 \u00b7 \u90eb\u90fd \u00b7 \u9f99\u6cc9\u9a7f \u00b7 \u5929\u5e9c\u65b0\u533a \u00b7 \u89c6\u9ad8<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n\n<footer class=\"footer\">\n  <h3>\u9f99\u8109\u6696\u901a \u00b7 \u987e\u95ee \u4f59\u7231\u82f1<\/h3>\n  <p>\u5357\u5bcc\u68ee\u95e8\u5e97\uff1a\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348 \uff5c \u7535\u8bdd 028-86131795<\/p>\n  <p>\u5317\u5bcc\u68ee\u95e8\u5e97\uff1a\u5bcc\u68ee\u7f8e\u5bb6\u5c45 \uff5c \u7535\u8bdd 028-65272586<\/p>\n  <div class=\"lm-store-grid\">\n    <div class=\"lm-store\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n      <div class=\"lm-st-name\">\u5357\u5bcc\u68ee\u95e8\u5e97\uff08\u5b9e\u666f\uff09<\/div>\n      <div>\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348 \uff5c <a href=\"tel:02886131795\">028-86131795<\/a><\/div>\n    <\/div>\n    <div class=\"lm-store\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n      <div class=\"lm-st-name\">\u5317\u5bcc\u68ee\u95e8\u5e97\uff08\u5b9e\u666f\uff09<\/div>\n      <div>\u5bcc\u68ee\u7f8e\u5bb6\u5c45 \uff5c <a href=\"tel:02865272586\">028-65272586<\/a><\/div>\n    <\/div>\n  \n  <\/div>\n\n<\/footer>\n","protected":false},"excerpt":{"rendered":"<p>\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-10237","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=10237\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=10237\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-09T07:38:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237\",\"name\":\"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/license-dealer.jpg\",\"datePublished\":\"2026-08-09T16:31:03+00:00\",\"dateModified\":\"2026-10-09T07:38:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/license-dealer.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/license-dealer.jpg\",\"width\":1280,\"height\":1850},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10237#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=10237","og_locale":"zh_CN","og_type":"article","og_title":"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=10237","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-09T07:38:19+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=10237","url":"https:\/\/longmai-nt.com\/?page_id=10237","name":"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=10237#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=10237#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg","datePublished":"2026-08-09T16:31:03+00:00","dateModified":"2026-10-09T07:38:19+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=10237#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=10237"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=10237#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/license-dealer.jpg","width":1280,"height":1850},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=10237#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u67ef\u8001\u5e08 \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696 + \u51c0\u6c34 + \u65b0\u98ce\u65b9\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10237"}],"version-history":[{"count":5,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10237\/revisions"}],"predecessor-version":[{"id":14306,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10237\/revisions\/14306"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}