{"id":1030,"date":"2026-05-19T14:52:16","date_gmt":"2026-05-19T06:52:16","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1030"},"modified":"2026-05-19T14:52:17","modified_gmt":"2026-05-19T06:52:17","slug":"%e5%88%98%e5%bf%a0%e7%a6%8f%e5%85%88%e7%94%9f%c2%b7%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e4%b8%8e%e5%9c%b0%e6%9a%96%e6%96%b9%e6%a1%88%e5%85%a8%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1030","title":{"rendered":"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u5218\u5fe0\u798f\u5148\u751f<br><strong>\u6237\u578b<\/strong>\uff1a\u56db\u5c42\u4f4f\u5b85\uff08\u542b\u8d1f\u4e00\u697c\uff09\uff0c\u91c7\u6696\u9762\u79ef\u7ea6225\u33a1<br><strong>\u9500\u552e\u987e\u95ee<\/strong>\uff1a\u8303\u4e3d\u5982<br><strong>\u8bbe\u8ba1\u5355\u4f4d<\/strong>\uff1a\u9f99\u8109\u6696\u901a\uff08\u59cb\u4e8e2004\uff09<br><strong>\u65b9\u6848\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670819\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e00\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u6c9f\u901a\u8bb0\u5f55\uff0c\u60a8\u7684\u6838\u5fc3\u5173\u6ce8\u70b9\u5982\u4e0b\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u8bf4\u7684<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/th><\/tr><\/thead><tbody><tr><td>\u201c\u6015\u5916\u673a\u574f\u4e86\u5168\u5c4b\u762b\u75ea\u201d<\/td><td>\u7cfb\u7edf\u53ef\u9760\u6027\u2014\u2014\u6545\u969c\u65f6\u6709\u6ca1\u6709\u5907\u7528\u65b9\u6848<\/td><\/tr><tr><td>\u201c\u7a7a\u8c03\u5730\u6696\u662f\u9690\u853d\u5de5\u7a0b\u201d<\/td><td>\u540e\u671f\u7ef4\u62a4\u2014\u2014\u574f\u4e86\u80fd\u4e0d\u80fd\u627e\u5230\u3001\u80fd\u4e0d\u80fd\u4fee<\/td><\/tr><tr><td>\u201c\u4e24\u8054\u4f9b\u548c\u5206\u4f53\u7cfb\u7edf\u54ea\u4e2a\u5212\u7b97\u201d<\/td><td>\u6027\u4ef7\u6bd4\u2014\u2014\u54c1\u724c\u6ea2\u4ef7\u662f\u5426\u5408\u7406<\/td><\/tr><tr><td>\u201c\u51ac\u5929\u91c7\u6696\u8d39\u7528\u201d<\/td><td>\u957f\u671f\u80fd\u8017\u2014\u2014\u6bcf\u4e2a\u6708\u8981\u82b1\u591a\u5c11\u94b1<\/td><\/tr><tr><td>\u201c\u56db\u5c42\u697c\u600e\u4e48\u914d\u4e0d\u6d6a\u8d39\u201d<\/td><td>\u591a\u5c42\u9002\u914d\u2014\u2014\u4e0d\u5e38\u7528\u7684\u533a\u57df\u522b\u767d\u82b1\u94b1<\/td><\/tr><tr><td>\u201c1-5\u4eba\u3001\u591a\u4e2a\u536b\u751f\u95f4\u70ed\u6c34\u201d<\/td><td>\u5927\u6c34\u91cf\u70ed\u6c34\u2014\u2014\u540c\u65f6\u7528\u6c34\u591f\u4e0d\u591f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e8c\u3001\u4e24\u5957\u65b9\u6848\u914d\u7f6e\u603b\u89c8<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6848\u4e00\uff1a\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u623f\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u51b7\u91cf<\/th><\/tr><\/thead><tbody><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5f71\u9662<\/td><td>13.8\u33a1<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2.5kW<\/td><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u516c\u533a\u68cb\u724c\u5ba4<\/td><td>22\u33a1<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4.0kW<\/td><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5065\u8eab\u533a<\/td><td>28\u33a1<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5.0kW<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u5385<\/td><td>35\u33a1<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>7.1kW<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u9910\u5385<\/td><td>26\u33a1<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5.0kW<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u8001\u4eba\u623f<\/td><td>32\u33a1<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>5.6kW<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>15\u33a1<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2.5kW<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u6c34\u5427\u533a<\/td><td>8.5\u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2kW<\/td><\/tr><tr><td>\u4e09\u697c<\/td><td>\u4e3b\u5367<\/td><td>22.1\u33a1<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>4.0kW<\/td><\/tr><tr><td>\u4e09\u697c<\/td><td>\u4e66\u623f<\/td><td>16.1\u33a1<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>3.2kW<\/td><\/tr><tr><td>\u2014<\/td><td><strong>\u5185\u673a\u5408\u8ba1<\/strong><\/td><td>\u2014<\/td><td><strong>10\u53f0<\/strong><\/td><td><strong>41.1kW<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-335FSXPN5Q<\/td><td>\u5236\u51b733.5kW\uff0c\u5236\u70ed37.5kW\uff0cAPF 5.0\uff0c380V<\/td><\/tr><tr><td>\u6c34\u6a21\u5757<\/td><td>RWMG-335FWXNZQ<\/td><td>\u5236\u70ed33.5kW\uff0cDC\u53d8\u9891\u6c34\u6cf5\uff0c35dB<\/td><\/tr><tr><td>\u5730\u6696\u9762\u79ef<\/td><td>\u2014<\/td><td>225\u33a1\uff0c\u7531\u6c34\u6a21\u5757\u63d0\u4f9b\u70ed\u6e90<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u8d85\u914d\u7387<\/strong>\uff1a41.1kW \u00f7 33.5kW =&nbsp;<strong>122.7%<\/strong>\uff08\u572850%-130%\u5141\u8bb8\u533a\u95f4\u5185\uff09<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6848\u4e8c\uff1a\u65e5\u7acb\u8212\u4eab + \u535a\u4e16\u51b7\u51dd\u7089\uff08\u6c1f\u7a7a\u8c03+\u71c3\u6c14\u5730\u6696\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3010\u8d1f\u4e00\u697c+\u4e00\u697c\u3011\u7cfb\u7edf<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u623f\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u51b7\u91cf<\/th><\/tr><\/thead><tbody><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5f71\u9662<\/td><td>13.8\u33a1<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>2.5kW<\/td><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u516c\u533a\u68cb\u724c\u5ba4<\/td><td>22\u33a1<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>4.0kW<\/td><\/tr><tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5065\u8eab\u533a<\/td><td>28\u33a1<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>5.0kW<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u5385<\/td><td>35\u33a1<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>7.1kW<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u9910\u5385<\/td><td>26\u33a1<\/td><td>RPIZ-45FSNAQD\/P<\/td><td>4.5kW<\/td><\/tr><tr><td>\u2014<\/td><td><strong>\u672c\u7cfb\u7edf\u5185\u673a\u5408\u8ba1<\/strong><\/td><td>\u2014<\/td><td><strong>5\u53f0<\/strong><\/td><td><strong>23.1kW<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-180HRNBQ<\/td><td>\u5236\u51b718.0kW\uff0c\u5236\u70ed20.0kW\uff0cAPF 5.50\uff0c\u53cc\u98ce\u6247<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3010\u4e8c\u697c+\u4e09\u697c\u3011\u7cfb\u7edf<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u623f\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u51b7\u91cf<\/th><\/tr><\/thead><tbody><tr><td>\u4e8c\u697c<\/td><td>\u8001\u4eba\u623f<\/td><td>32\u33a1<\/td><td>RPIZ-56FSNAQD\/P<\/td><td>5.6kW<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>15\u33a1<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>2.5kW<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u6c34\u5427\u533a<\/td><td>8.5\u33a1<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2.2kW<\/td><\/tr><tr><td>\u4e09\u697c<\/td><td>\u4e3b\u5367<\/td><td>22.1\u33a1<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>4.0kW<\/td><\/tr><tr><td>\u4e09\u697c<\/td><td>\u4e66\u623f<\/td><td>16.1\u33a1<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>3.2kW<\/td><\/tr><tr><td>\u2014<\/td><td><strong>\u672c\u7cfb\u7edf\u5185\u673a\u5408\u8ba1<\/strong><\/td><td>\u2014<\/td><td><strong>5\u53f0<\/strong><\/td><td><strong>17.5kW<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-160HRNAQ<\/td><td>\u5236\u51b715.5kW\uff0c\u5236\u70ed17.0kW\uff0cAPF 5.50\uff0c\u5355\u98ce\u6247<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>\u5730\u6696\u6696\u6e90<\/td><td>\u535a\u4e16Condens 3260W 24kW<\/td><td>\u70ed\u6548\u7387108%\uff0c\u6700\u5c0f\u8f93\u51fa\u7ea65-7kW<\/td><\/tr><tr><td>\u5730\u6696\u9762\u79ef<\/td><td>\u2014<\/td><td>225\u33a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e09\u3001\u6838\u5fc3\u53c2\u6570\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff1a\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff1a\u8212\u4eab+\u51b7\u51dd\u7089<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u52bf\u65b9<\/th><\/tr><\/thead><tbody><tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td>\u5929\u6c1f\u5730\u6c34\uff08\u5355\u5957\u4e3b\u673a\uff09<\/td><td>\u6c1f\u7a7a\u8c03+\u71c3\u6c14\u5730\u6696\uff08\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff09<\/td><td>\u65b9\u6848\u4e8c\u5197\u4f59\u6027\u66f4\u9ad8<\/td><\/tr><tr><td>\u7a7a\u8c03\u5916\u673a<\/td><td>\u5c0a\u777f\u5168\u6548335 \u00d7 1\u53f0<\/td><td>\u8212\u4eab180 + \u8212\u4eab160 \u00d7 2\u53f0<\/td><td>\u65b9\u6848\u4e8c\u4e92\u4e3a\u5907\u4efd<\/td><\/tr><tr><td>\u7a7a\u8c03\u5185\u673a<\/td><td>\u5168\u6548\u4e09\u7ba1DC\u51c0\u5316\u578b\uff0810\u53f0\uff09<\/td><td>\u8212\u4eabDC\u6807\u51c6\u578b\uff0810\u53f0\uff09<\/td><td>\u65b9\u6848\u4e00\u5065\u5eb7\u529f\u80fd\u5b8c\u80dc<\/td><\/tr><tr><td>\u5730\u6696\u70ed\u6e90<\/td><td>\u7a7a\u6c14\u80fd\u70ed\u6cf5\uff08\u6c34\u6a21\u5757\uff09<\/td><td>\u535a\u4e16\u51b7\u51dd\u708924kW<\/td><td>\u65b9\u6848\u4e00\u8fd0\u884c\u8d39\u66f4\u4f4e<\/td><\/tr><tr><td>\u7a7a\u8c03APF\u80fd\u6548<\/td><td>5.0<\/td><td>5.50 \/ 5.50<\/td><td>\u65b9\u6848\u4e8c\u80fd\u6548\u7565\u9ad8<\/td><\/tr><tr><td>\u5730\u6696\u6708\u8d39\uff08225\u33a1\uff09<\/td><td>\u7ea6800-900\u5143<\/td><td>\u7ea62,000-3,000\u5143<\/td><td>\u65b9\u6848\u4e00\u5e74\u77011.5-2\u4e07\u5143<\/td><\/tr><tr><td>\u7a7a\u8c03\u8212\u9002\u5ea6<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50\uff08\u6e29\u6e7f\u53cc\u63a7\uff09<\/td><td>\u2b50\u2b50\u2b50\uff08\u57fa\u7840\u51b7\u6696\uff09<\/td><td>\u65b9\u6848\u4e00\u5b8c\u80dc<\/td><\/tr><tr><td>\u5065\u5eb7\u51c0\u5316<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50\uff08\u6807\u914dPE+\u51c0\u5316\uff09<\/td><td>\u2b50\u2b50\uff08\u53ef\u9009\u914dPE\uff09<\/td><td>\u65b9\u6848\u4e00\u5b8c\u80dc<\/td><\/tr><tr><td>\u7cfb\u7edf\u5197\u4f59\u6027<\/td><td>\u2b50\u2b50\uff08\u5355\u5957\uff09<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50\uff08\u4e24\u5957\u72ec\u7acb\uff09<\/td><td>\u65b9\u6848\u4e8c\u5b8c\u80dc<\/td><\/tr><tr><td>\u70ed\u6c34\u6269\u5c55<\/td><td>\u53ef\u5347\u7ea7\u4e09\u8054\u4f9b<\/td><td>\u9700\u72ec\u7acb\u70ed\u6c34\u7cfb\u7edf<\/td><td>\u65b9\u6848\u4e00\u6269\u5c55\u6027\u5f3a<\/td><\/tr><tr><td>20\u5e74\u603b\u6295\u5165<\/td><td>\u66f4\u4f4e\uff08\u8282\u80fd\u7701\u56de\u5dee\u4ef7\uff09<\/td><td>\u8f83\u9ad8<\/td><td>\u65b9\u6848\u4e00\u957f\u671f\u4ef7\u503c\u9ad8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u56db\u3001\u900f\u660e\u62a5\u4ef7\uff088\u6298\u6838\u7b97\uff09<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6848\u4e00\uff1a\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">8\u6298\u540e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39\/\u53f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-335FSXPN5Q<\/td><td>1<\/td><td>38,913<\/td><td>31,130<\/td><td>600<\/td><td>600<\/td><\/tr><tr><td>\u6c34\u6a21\u5757<\/td><td>RWMG-335FWXNZQ<\/td><td>1<\/td><td>12,500<\/td><td>10,000<\/td><td>625<\/td><td>625<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a25<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2<\/td><td>5,050\u00d72<\/td><td>8,080<\/td><td>1,900\u00d72<\/td><td>3,800<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a22<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>1<\/td><td>5,050<\/td><td>4,040<\/td><td>1,900<\/td><td>1,900<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a32<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>1<\/td><td>5,238<\/td><td>4,190<\/td><td>1,900<\/td><td>1,900<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a40<\/td><td>RPIZ-40FSVN2QB\/PC<\/td><td>2<\/td><td>5,238\u00d72<\/td><td>8,380<\/td><td>1,900\u00d72<\/td><td>3,800<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a50<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>2<\/td><td>5,663\u00d72<\/td><td>9,060<\/td><td>1,900\u00d72<\/td><td>3,800<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a56<\/td><td>RPIZ-56FSVN2QB\/PC<\/td><td>1<\/td><td>5,663<\/td><td>4,530<\/td><td>1,900<\/td><td>1,900<\/td><\/tr><tr><td>\u5168\u6548\u4e09\u7ba1\u5185\u673a71<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1<\/td><td>5,825<\/td><td>4,660<\/td><td>1,900<\/td><td>1,900<\/td><\/tr><tr><td><strong>\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td><strong>84,070<\/strong><\/td><td>\u2014<\/td><td><strong>19,225<\/strong><\/td><\/tr><tr><td><strong>\u5730\u6696\uff08225\u33a1\uff09<\/strong><\/td><td>\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8<\/td><td>\u2014<\/td><td>\u2014<\/td><td>179\u5143\/\u33a1<\/td><td>40,275<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u8bbe\u5907+\u5730\u6696\u5408\u8ba1<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td><strong>\u7ea6143,570\u5143<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6ce8<\/strong>\uff1a\u4ee5\u4e0a\u4e0d\u542b\u7ebf\u63a7\u5668\u30013D\u98ce\u53e3\u7b49\u914d\u4ef6\uff0c\u4e0d\u542b\u70ed\u6c34\u7cfb\u7edf\u3002\u5730\u6696\u6309\u8282\u80fd\u73af\u4fdd\u5b9a\u5236\u5957\u9910179\u5143\/\u33a1\u62a5\u4ef7\uff08\u542b\u7ba1\u9053\u3001\u5206\u96c6\u6c34\u5668\u3001\u66fc\u745e\u5fb7WiFi\u7ebf\u63a7\u3001\u8054\u52a8\u63a7\u5236\uff09\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6848\u4e8c\uff1a\u65e5\u7acb\u8212\u4eab + \u535a\u4e16\u51b7\u51dd\u7089<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3010\u8212\u4eab\u5185\u673a\u00d710\u53f0\u3011<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">8\u6298\u540e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39\/\u53f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u8212\u4eab\u5185\u673a25<\/td><td>RPIZ-25FSNAQD\/P<\/td><td>2<\/td><td>3,050\u00d72<\/td><td>4,880<\/td><td>1,600\u00d72<\/td><td>3,200<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a22<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>1<\/td><td>3,013<\/td><td>2,410<\/td><td>1,600<\/td><td>1,600<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a32<\/td><td>RPIZ-32FSNAQD\/P<\/td><td>1<\/td><td>3,100<\/td><td>2,480<\/td><td>1,600<\/td><td>1,600<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a40<\/td><td>RPIZ-40FSNAQD\/P<\/td><td>2<\/td><td>3,163\u00d72<\/td><td>5,060<\/td><td>1,600\u00d72<\/td><td>3,200<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a45<\/td><td>RPIZ-45FSNAQD\/P<\/td><td>1<\/td><td>3,250<\/td><td>2,600<\/td><td>1,600<\/td><td>1,600<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a50<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>1<\/td><td>3,325<\/td><td>2,660<\/td><td>1,600<\/td><td>1,600<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a56<\/td><td>RPIZ-56FSNAQD\/P<\/td><td>1<\/td><td>3,388<\/td><td>2,710<\/td><td>1,600<\/td><td>1,600<\/td><\/tr><tr><td>\u8212\u4eab\u5185\u673a71<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>1<\/td><td>3,513<\/td><td>2,810<\/td><td>1,600<\/td><td>1,600<\/td><\/tr><tr><td><strong>\u5185\u673a\u5c0f\u8ba1<\/strong><\/td><td>\u2014<\/td><td><strong>10\u53f0<\/strong><\/td><td>\u2014<\/td><td><strong>25,610<\/strong><\/td><td>\u2014<\/td><td><strong>16,000<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3010\u5916\u673a+\u5730\u6696\u3011<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">8\u6298\u540e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39\/\u53f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u8212\u4eab\u5916\u673a180<\/td><td>RAS-180HRNBQ<\/td><td>1<\/td><td>16,150<\/td><td>12,920<\/td><td>600<\/td><td>600<\/td><\/tr><tr><td>\u8212\u4eab\u5916\u673a160<\/td><td>RAS-160HRNAQ<\/td><td>1<\/td><td>13,775<\/td><td>11,020<\/td><td>600<\/td><td>600<\/td><\/tr><tr><td>\u535a\u4e16\u51b7\u51dd\u7089<\/td><td>Condens 3260W 24kW<\/td><td>1<\/td><td>9,325<\/td><td>7,460<\/td><td>600<\/td><td>600<\/td><\/tr><tr><td><strong>\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td><strong>57,010<\/strong><\/td><td>\u2014<\/td><td><strong>17,800<\/strong><\/td><\/tr><tr><td><strong>\u5730\u6696\uff08225\u33a1\uff09<\/strong><\/td><td>\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8<\/td><td>\u2014<\/td><td>\u2014<\/td><td>179\u5143\/\u33a1<\/td><td>40,275<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td><strong>\u7ea6115,085\u5143<\/strong><\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6ce8<\/strong>\uff1a\u4ee5\u4e0a\u4e0d\u542b\u7ebf\u63a7\u5668\u30013D\u98ce\u53e3\u7b49\u914d\u4ef6\uff0c\u4e0d\u542b\u70ed\u6c34\u7cfb\u7edf\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e94\u3001\u4e24\u5957\u65b9\u6848\u603b\u4ef7\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8d39\u7528\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff1a\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff1a\u8212\u4eab+\u51b7\u51dd\u7089<\/th><\/tr><\/thead><tbody><tr><td>\u7a7a\u8c03\u8bbe\u5907\uff08\u542b\u5185\u673a\u3001\u5916\u673a\u3001\u6c34\u6a21\u5757\uff09<\/td><td>84,070\u5143<\/td><td>57,010\u5143<\/td><\/tr><tr><td>\u7a7a\u8c03\u5b89\u88c5\u8d39<\/td><td>19,225\u5143<\/td><td>17,800\u5143<\/td><\/tr><tr><td>\u5730\u6696\uff08225\u33a1\uff0c\u8282\u80fd\u5b9a\u5236\u5957\u9910\uff09<\/td><td>40,275\u5143<\/td><td>40,275\u5143<\/td><\/tr><tr><td><strong>\u65b9\u6848\u5408\u8ba1\uff08\u4e0d\u542b\u914d\u4ef6\/\u70ed\u6c34\uff09<\/strong><\/td><td><strong>\u7ea6143,570\u5143<\/strong><\/td><td><strong>\u7ea6115,085\u5143<\/strong><\/td><\/tr><tr><td><strong>\u521d\u6295\u8d44\u5dee\u989d<\/strong><\/td><td>\u65b9\u6848\u4e00\u6bd4\u65b9\u6848\u4e8c\u9ad8&nbsp;<strong>\u7ea628,485\u5143<\/strong><\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u516d\u300120\u5e74\u603b\u6295\u5165\u5bf9\u6bd4<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u8ba1\u7b97\u524d\u63d0<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53d6\u503c<\/th><\/tr><\/thead><tbody><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>225\u33a1<\/td><\/tr><tr><td>\u5e74\u91c7\u6696\u5929\u6570<\/td><td>120\u5929<\/td><\/tr><tr><td>\u7535\u4ef7<\/td><td>0.5\u5143\/\u5ea6<\/td><\/tr><tr><td>\u6c14\u4ef7<\/td><td>2.5\u5143\/\u65b9<\/td><\/tr><tr><td>\u4f7f\u7528\u5e74\u9650<\/td><td>20\u5e74<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u5e74\u8fd0\u884c\u8d39\u8ba1\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u6708\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u91c7\u6696\u8d39\uff084\u4e2a\u6708\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u65b9\u6848\u4e00\uff08\u7a7a\u6c14\u80fd\uff09<\/td><td>800-900\u5143<\/td><td>\u7ea63,400\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e8c\uff08\u71c3\u6c14\uff09<\/td><td>2,000-3,000\u5143<\/td><td>\u7ea610,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5e74\u8fd0\u884c\u8d39\u5dee\u989d<\/strong>\uff1a\u65b9\u6848\u4e8c\u6bd4\u65b9\u6848\u4e00\u591a\u7ea6&nbsp;<strong>6,600\u5143\/\u5e74<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">20\u5e74\u603b\u6295\u5165<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8d39\u7528\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff1a\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff1a\u8212\u4eab+\u51b7\u51dd\u7089<\/th><\/tr><\/thead><tbody><tr><td>\u521d\u6295\u8d44<\/td><td>143,570\u5143<\/td><td>115,085\u5143<\/td><\/tr><tr><td>20\u5e74\u91c7\u6696\u8d39<\/td><td>3,400\u00d720 = 68,000\u5143<\/td><td>10,000\u00d720 = 200,000\u5143<\/td><\/tr><tr><td>\u8bbe\u5907\u66f4\u6362\uff0820\u5e74\u5185\uff09<\/td><td>0\u5143<\/td><td>\u51b7\u51dd\u7089\u66f4\u6362\u4e00\u6b21 +15,000\u5143<\/td><\/tr><tr><td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td><td><strong>\u7ea6211,570\u5143<\/strong><\/td><td><strong>\u7ea6330,085\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u65b9\u6848\u4e0020\u5e74\u603b\u6295\u5165\u6bd4\u65b9\u6848\u4e8c\u4f4e&nbsp;<strong>\u7ea6118,515\u5143<\/strong>\u3002\u521d\u6295\u8d44\u591a28,485\u5143\uff0c4-5\u5e74\u5373\u53ef\u901a\u8fc7\u8282\u80fd\u6536\u56de\u5dee\u4ef7\uff0c\u4e4b\u540e14-15\u5e74\u51c0\u7701\u7ea69\u4e07\u5143\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e03\u3001\u70ed\u6c34\u7cfb\u7edf\u5efa\u8bae<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u5bb6\u5e38\u4f4f1-5\u4eba\u3001\u591a\u5c42\u591a\u536b\u751f\u95f4\uff0c\u4e24\u7528\u7089\u70ed\u6c34\u80fd\u529b\u4e0d\u8db3\u3002\u5efa\u8bae\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u914d\u7f6e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td><strong>\u72ec\u7acb\u70ed\u6c34\u5668<\/strong><\/td><td>\u745e\u7f8e20L\u6052\u6e29\u70ed\u6c34\u5668 \u6216 \u6797\u518520L\u96f6\u51b7\u6c34<\/td><td>\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\uff0c\u7a33\u5b9a\u53ef\u9760<\/td><\/tr><tr><td><strong>\u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668<\/strong><\/td><td>\u6b27\u7279200L\u5bb9\u79ef\u5f0f<\/td><td>\u524a\u5cf0\u586b\u8c37\uff0c\u6ee1\u8db3\u591a\u70b9\u540c\u65f6\u7528\u6c34<\/td><\/tr><tr><td><strong>\u4e09\u8054\u4f9b\u5347\u7ea7\uff08\u4ec5\u65b9\u6848\u4e00\uff09<\/strong><\/td><td>\u52a0\u88c5\u6362\u70ed\u6c34\u7bb1<\/td><td>\u590f\u5929\u514d\u8d39\u56de\u6536\u5e9f\u70ed\u52a0\u70ed\u70ed\u6c34<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6d3b\u52a8\u63d0\u9192<\/strong>\uff1a\u6d3b\u52a8\u671f\u95f4\uff0c\u65b9\u6848\u4e8c\u9009\u91c7\u6696\u5373\u9001\u745e\u7f8e13L\u6052\u6e29\u70ed\u6c34\u5668\uff08\u4ef7\u503c2,999\u5143\uff09\uff0c\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u9001\u745e\u7f8e16L\u6052\u6e29\u70ed\u6c34\u5668\uff08\u4ef7\u503c3,999\u5143\uff09\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u516b\u3001\u9009\u8d2d\u5efa\u8bae<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9009\u62e9\u65b9\u5411<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9009\u65b9\u6848\u4e00\uff08\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b\uff09\u5982\u679c\uff1a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9009\u65b9\u6848\u4e8c\uff08\u8212\u4eab+\u51b7\u51dd\u7089\uff09\u5982\u679c\uff1a<\/th><\/tr><\/thead><tbody><tr><td>\u6838\u5fc3\u8ffd\u6c42<\/td><td>\u6781\u81f4\u8212\u9002\u3001\u5065\u5eb7\u3001\u8282\u80fd<\/td><td>\u7cfb\u7edf\u53ef\u9760\u6027\u3001\u521d\u6295\u8d44\u53ef\u63a7<\/td><\/tr><tr><td>\u91c7\u6696\u8d39\u654f\u611f\u5ea6<\/td><td>\u975e\u5e38\u5728\u610f\uff0c\u5e0c\u671b\u8d8a\u7701\u8d8a\u597d<\/td><td>\u4e0d\u592a\u654f\u611f<\/td><\/tr><tr><td>\u8212\u9002\u5065\u5eb7\u8981\u6c42<\/td><td>\u9700\u8981\u6e29\u6e7f\u53cc\u63a7\u3001\u6807\u914d\u51c0\u5316<\/td><td>\u6ee1\u8db3\u57fa\u7840\u51b7\u6696\u5373\u53ef<\/td><\/tr><tr><td>\u957f\u671f\u5c45\u4f4f\u8ba1\u5212<\/td><td>\u957f\u671f\u81ea\u4f4f\uff0815\u5e74\u4ee5\u4e0a\uff09<\/td><td>\u77ed\u671f\u8fc7\u6e21\u6216\u4e2d\u671f\u8ba1\u5212\u6362\u623f<\/td><\/tr><tr><td>\u5bf9\u7cfb\u7edf\u5197\u4f59\u7684\u62c5\u5fe7<\/td><td>\u53ef\u63a5\u53d7\u5355\u5957\u7cfb\u7edf<\/td><td>\u975e\u5e38\u5728\u610f\uff0c\u5e0c\u671b\u4e24\u5957\u72ec\u7acb\u5907\u4efd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e5d\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u4f1a\u5458\u6743\u76ca<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u670d\u52a1\u627f\u8bfa<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/td><\/tr><tr><td>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><\/tr><tr><td>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u4f1a\u5458\u6743\u76ca\uff08\u6d3b\u52a8\u671f\u95f4\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u76ca<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u6696\u901a\u91d1\u989d<\/td><td>\u7b7e\u7ea6\u90011000\u5143\uff08\u53ef\u62b5\u6263\u4f1a\u5458\u8d39\/\u8bbe\u5907\u6b3e\/\u5b89\u88c5\u8d39\uff09<\/td><\/tr><tr><td>\u65e5\u7acb\u5382\u8865\uff08\u65b9\u6848\u4e00\uff09<\/td><td>\u5c0a\u777f\u5168\u6548335\u21922000\u5143\/\u6237<\/td><\/tr><tr><td>\u65e5\u7acb\u5382\u8865\uff08\u65b9\u6848\u4e8c\uff09<\/td><td>\u8212\u4eab\u7cfb\u5217\u2192500\u5143\/\u6237<\/td><\/tr><tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td>\u5165\u4f1a\u5458\u540e\u8212\u4eab\/\u5168\u6548\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u91c7\u6696\u4e13\u4eab\uff08\u65b9\u6848\u4e8c\uff09<\/td><td>\u535a\u4e16\u51b7\u51dd\u7089\u9001\u745e\u7f8e13L\u6052\u6e29\u70ed\u6c34\u5668\uff08\u4ef7\u503c2,999\u5143\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f1a\u5458\u5e74\u8d39<\/strong>\uff1a199\u5143\/\u5e74\uff08\u9996\u5e74\u53ef\u7528\u6696\u901a\u91d1\u989d\u62b5\u6263\uff09<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5341\u3001\u65b9\u6848\u4e66\u9644\u6ce8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u6e29\u99a8\u63d0\u793a<\/strong>\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u6d89\u53ca\u4e13\u4e1a\u6280\u672f\u53c2\u6570\u548c\u8bbe\u8ba1\u903b\u8f91\uff0c\u5982\u679c\u60a8\u89c9\u5f97\u5185\u5bb9\u590d\u6742\uff0c\u53ef\u4ee5\uff1a<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>\u5c06\u672c\u65b9\u6848\u53d1\u9001\u7ed9\u4efb\u610fAI\u52a9\u624b<\/li>\n\n\n\n<li>\u540c\u65f6\u5c06\u5176\u4ed6\u5546\u5bb6\u7684\u65b9\u6848\u4e00\u8d77\u53d1\u7ed9AI<\/li>\n\n\n\n<li>\u8ba9AI\u5e2e\u60a8\u5bf9\u6bd4\u5206\u6790\uff0c\u7ed9\u51fa\u5ba2\u89c2\u5efa\u8bae<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u6696\u901a \u00b7 \u59cb\u4e8e2004<\/strong><br><strong>\u9500\u552e\u987e\u95ee<\/strong>\uff1a\u8303\u4e3d\u5982<br><strong>\u8054\u7cfb\u7535\u8bdd<\/strong>\uff1a13398198375<br><strong>\u95e8\u5e97\u5730\u5740<\/strong>\uff1a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986\u4e09\u697cA-348<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\uff1a\u5218\u5fe0\u798f\u5148\u751f\u6237\u578b\uff1a\u56db\u5c42\u4f4f\u5b85\uff08\u542b\u8d1f\u4e00\u697c [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1030","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a225\u33a1\u56db\u5c42\u4f4f\u5b85\uff0c\u5c0a\u777f\u5168\u6548335 vs \u8212\u4eab\u53cc\u7cfb\u7edf\u30028\u6298\u6838\u7b97\u8bbe\u5907\u4ef7\uff0c20\u5e74\u603b\u6295\u5165\u5dee11.8\u4e07\u3002\u9f99\u8109\u6696\u901a\uff082004\u5e74\u6210\u7acb\uff09\u5b98\u65b9\u65b9\u6848\u5168\u4e66\uff0c\u542b\u914d\u7f6e\u3001\u62a5\u4ef7\u3001\u80fd\u8017\u5bf9\u6bd4\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1030\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a225\u33a1\u56db\u5c42\u4f4f\u5b85\uff0c\u5c0a\u777f\u5168\u6548335 vs \u8212\u4eab\u53cc\u7cfb\u7edf\u30028\u6298\u6838\u7b97\u8bbe\u5907\u4ef7\uff0c20\u5e74\u603b\u6295\u5165\u5dee11.8\u4e07\u3002\u9f99\u8109\u6696\u901a\uff082004\u5e74\u6210\u7acb\uff09\u5b98\u65b9\u65b9\u6848\u5168\u4e66\uff0c\u542b\u914d\u7f6e\u3001\u62a5\u4ef7\u3001\u80fd\u8017\u5bf9\u6bd4\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1030\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-19T06:52:17+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1030\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1030\",\"name\":\"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-19T06:52:16+00:00\",\"dateModified\":\"2026-05-19T06:52:17+00:00\",\"description\":\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a225\u33a1\u56db\u5c42\u4f4f\u5b85\uff0c\u5c0a\u777f\u5168\u6548335 vs \u8212\u4eab\u53cc\u7cfb\u7edf\u30028\u6298\u6838\u7b97\u8bbe\u5907\u4ef7\uff0c20\u5e74\u603b\u6295\u5165\u5dee11.8\u4e07\u3002\u9f99\u8109\u6696\u901a\uff082004\u5e74\u6210\u7acb\uff09\u5b98\u65b9\u65b9\u6848\u5168\u4e66\uff0c\u542b\u914d\u7f6e\u3001\u62a5\u4ef7\u3001\u80fd\u8017\u5bf9\u6bd4\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1030#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1030\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1030#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","description":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a225\u33a1\u56db\u5c42\u4f4f\u5b85\uff0c\u5c0a\u777f\u5168\u6548335 vs \u8212\u4eab\u53cc\u7cfb\u7edf\u30028\u6298\u6838\u7b97\u8bbe\u5907\u4ef7\uff0c20\u5e74\u603b\u6295\u5165\u5dee11.8\u4e07\u3002\u9f99\u8109\u6696\u901a\uff082004\u5e74\u6210\u7acb\uff09\u5b98\u65b9\u65b9\u6848\u5168\u4e66\uff0c\u542b\u914d\u7f6e\u3001\u62a5\u4ef7\u3001\u80fd\u8017\u5bf9\u6bd4\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1030","og_locale":"zh_CN","og_type":"article","og_title":"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a225\u33a1\u56db\u5c42\u4f4f\u5b85\uff0c\u5c0a\u777f\u5168\u6548335 vs \u8212\u4eab\u53cc\u7cfb\u7edf\u30028\u6298\u6838\u7b97\u8bbe\u5907\u4ef7\uff0c20\u5e74\u603b\u6295\u5165\u5dee11.8\u4e07\u3002\u9f99\u8109\u6696\u901a\uff082004\u5e74\u6210\u7acb\uff09\u5b98\u65b9\u65b9\u6848\u5168\u4e66\uff0c\u542b\u914d\u7f6e\u3001\u62a5\u4ef7\u3001\u80fd\u8017\u5bf9\u6bd4\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=1030","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-19T06:52:17+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1030","url":"https:\/\/longmai-nt.com\/?page_id=1030","name":"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-19T06:52:16+00:00","dateModified":"2026-05-19T06:52:17+00:00","description":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff1a225\u33a1\u56db\u5c42\u4f4f\u5b85\uff0c\u5c0a\u777f\u5168\u6548335 vs \u8212\u4eab\u53cc\u7cfb\u7edf\u30028\u6298\u6838\u7b97\u8bbe\u5907\u4ef7\uff0c20\u5e74\u603b\u6295\u5165\u5dee11.8\u4e07\u3002\u9f99\u8109\u6696\u901a\uff082004\u5e74\u6210\u7acb\uff09\u5b98\u65b9\u65b9\u6848\u5168\u4e66\uff0c\u542b\u914d\u7f6e\u3001\u62a5\u4ef7\u3001\u80fd\u8017\u5bf9\u6bd4\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1030#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1030"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1030#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5218\u5fe0\u798f\u5148\u751f\u00b7\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u65b9\u6848\u5168\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1030"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1030\/revisions"}],"predecessor-version":[{"id":2403,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1030\/revisions\/2403"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}