{"id":10632,"date":"2026-08-18T15:07:17","date_gmt":"2026-08-18T07:07:17","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=10632"},"modified":"2026-10-22T16:41:17","modified_gmt":"2026-10-22T08:41:17","slug":"%e6%88%90%e9%83%bd%e8%a5%bf%e5%8d%8e%e8%8b%91%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab200%e4%b8%80%e6%8b%96%e5%85%ad%e6%9b%bc%e7%91%9e%e5%be%b7%e5%86%b7%e5%87%9d%e7%82%89%e5%9c%b0%e6%9a%96%e6%97%a5","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=10632","title":{"rendered":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a"},"content":{"rendered":"\n\n<!-- canonical: \u53d1\u5e03\u65f6\u6539\u4e3a\u672c\u9875\u771f\u5b9e page_id\uff0c\u52ff\u6307\u5411 2297 \u805a\u5408\u9875\uff08\u5426\u5219\u88ab\u5224\u91cd\u590d\u5185\u5bb9\uff09 -->\n\n<!-- og:url: \u53d1\u5e03\u65f6\u540c\u6b65\u6539\u4e3a\u672c\u9875\u771f\u5b9e page_id -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a\",\n  \"description\": \"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u9f99\u8109\u6696\u901a\u7b7e\u5355\u4ea4\u4ed8\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247200\u578b\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\uff08\u5ba2\u9910\u538571+56\u3001\u4e3b\u536756\u3001\u8863\u5e3d\u95f422\u3001\u4e66\u623f18\u3001\u5065\u8eab\u623f18\uff09\u3001\u66fc\u745e\u5fb7\u5c0f\u536124kW\u51b7\u51dd\u7089\u5730\u66969\u56de\u8def\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u3002\u6210\u90fd\u5168\u57df12\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u3002\",\n  \"author\": {\n    \"@type\": \"Person\",\n    \"@id\": \"https:\/\/longmai-nt.com\/#person-hy\",\n    \"name\": \"\u9ec4\u52c7\",\n    \"jobTitle\": \"\u65b9\u6848\u987e\u95ee\",\n    \"telephone\": \"028-65272586\",\n    \"description\": \"\u9f99\u8109\u6696\u901a\uff08\u5317\u5bcc\u68ee\u95e8\u5e97\uff09\u65b9\u6848\u987e\u95ee\u9ec4\u52c7\uff0c2004\u5e74\u8d77\u6df1\u8015\u6696\u901a\uff0c\u4e13\u6ce8\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u4e0e\u4e24\u8054\u4f9b\u7cfb\u7edf\u65b9\u6848\u8bbe\u8ba1\"\n  },\n  \"publisher\": { \"@type\": \"Organization\", \"name\": \"\u9f99\u8109\u6696\u901a\", \"url\": \"https:\/\/longmai-nt.com\" },\n  \"datePublished\": \"2026-07-16\",\n  \"dateModified\": \"2026-08-18\"\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\"@type\":\"Question\",\"name\":\"132\u33a1\u4e09\u5ba4\u4e24\u5385\u914d\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u516d\u591f\u7528\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u591f\u7528\u3002\u5ba2\u9910\u5385\u53a8\u623f\u9633\u53f067.32\u33a1\u914d71+56\u4e24\u53f0\u3001\u4e3b\u5367\u8d77\u5c45\u5ba433.5\u33a1\u914d56\u3001\u8863\u5e3d\u95f422\u3001\u4e66\u623f18\u3001\u5065\u8eab\u623f18\uff0c\u51716\u53f0\u5185\u673a\u8986\u76d6\u5168\u5c4b\uff1b\u5916\u673a\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247200\u578b\uff0c\u5355\u5f00\u6216\u5168\u5f00\u90fd\u4ece\u5bb9\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u4e00\u8d77\u505a\u6709\u4ec0\u4e48\u597d\u5904\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e09\u7cfb\u7edf\u534f\u540c\u8986\u76d6\u51b7\u6696\u4e0e\u7a7a\u6c14\u54c1\u8d28\uff1a\u4e2d\u592e\u7a7a\u8c03\u5236\u51b7\u5236\u70ed\u3001\u51b7\u51dd\u7089\u5730\u6696\u51ac\u5b63\u91c7\u6696\u3001\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u6362\u6c14\u51c0\u5316\u3002\u4e00\u6b21\u52d8\u6d4b\u4e00\u6b21\u65bd\u5de5\uff0c\u7ba1\u8def\u4e0e\u6e29\u63a7\u8054\u52a8\u66f4\u534f\u8c03\uff0c\u957f\u671f\u8fd0\u7ef4\u4e5f\u66f4\u7701\u5fc3\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u4f59\u70ed\uff0c\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u91c7\u6696\u5b63\u71c3\u6c14\u6d88\u8017\u66f4\u4f4e\uff1b\u914d\u5408\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u4e0e\u5206\u533a\u57dfWiFi\u6e29\u63a7\u6309\u9700\u542f\u505c\uff0c\u957f\u671f\u4f7f\u7528\u66f4\u7701\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u5168\u70ed\u4ea4\u6362\u6709\u4ec0\u4e48\u7528\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5168\u70ed\u4ea4\u6362\u5668\u5728\u6392\u51fa\u6d4a\u6c14\u3001\u5f15\u5165\u65b0\u98ce\u65f6\u56de\u6536\u6392\u98ce\u80fd\u91cf\uff0c\u9884\u51b7\u9884\u70ed\u65b0\u98ce\uff0c\u51cf\u5c11\u7a7a\u8c03\u4e0e\u5730\u6696\u8d1f\u8377\uff0c\u540c\u65f6\u8fc7\u6ee4PM2.5\uff0c\u63d0\u5347\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e00\u62d6\u516d\u8fde\u63a5\u7387\u600e\u4e48\u7b97\u3001\u662f\u5426\u5408\u89c4\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6c1f\u7cfb\u7edf\u5141\u8bb8\u8fde\u63a5\u738750%-130%\u3002\u672c\u65b9\u6848\u5185\u673a\u603b\u5bb9\u91cf\u6309\u5404\u5ba4\u5185\u673a\u6807\u79f0\u5408\u8ba1\u3001\u5916\u673a\u4e3a\u8212\u4eab200\u578b\uff0c\u5355\u5f00\/\u5168\u5f00\u5747\u7559\u6709\u5408\u89c4\u4f59\u91cf\uff0c\u9009\u578b\u5b89\u5168\u4e0d\u8d85\u914d\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u897f\u534e\u82d1\u8fd9\u5957\u65b9\u6848\u9002\u5408\u591a\u5927\u9762\u79ef\u7684\u5bb6\u5ead\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u9002\u5408\u5efa\u9762\u7ea6130\u33a1\u5de6\u53f3\u7684\u4e09\u5ba4\u4e24\u5385\u53ca\u4ee5\u4e0a\u6237\u578b\uff0c\u5c24\u5176\u5ba2\u9910\u5385+\u53a8\u623f+\u9633\u53f0\u8fde\u6210\u5927\u5f00\u95f4\u3001\u591a\u623f\u95f4\u9700\u72ec\u7acb\u63a7\u6e29\u7684\u5bb6\u5ead\uff1b\u5177\u4f53\u4ee5\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u7684\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u4e3a\u51c6\u3002\"}}\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"LocalBusiness\",\n  \"name\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"url\": \"https:\/\/longmai-nt.com\",\n  \"telephone\": \"+86-028-86131795\",\n  \"foundingDate\": \"2004\",\n  \"address\": {\n    \"@type\": \"PostalAddress\",\n    \"addressLocality\": \"\u6210\u90fd\u5e02\",\n    \"addressRegion\": \"\u56db\u5ddd\u7701\",\n    \"addressCountry\": \"CN\"\n  },\n  \"areaServed\": \"\u6210\u90fd\u5e02\",\n  \"description\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\uff082004\u5e74\u6210\u7acb\uff09\u4e13\u6ce8\u5bb6\u5ead\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u4e0e\u7a7a\u6c14\u6e90\u70ed\u6cf5\u7cfb\u7edf\u96c6\u6210\uff0c\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u7ecf\u9500\u5546\uff0c\u5357\u5bcc\u68ee\u4e0e\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\u670d\u52a1\u6210\u90fd\u5168\u57df12\u533a\u3002\"\n}\n<\/script>\n<style>\n.lm-wrap{\n  --blue:#1a3a6e;--green:#3f7d5a;--gold:#c5a55a;\n  --dark:#1a3a6e;--bg:#f4f7fb;--card:#ffffff;--text:#2a3340;--muted:#6b7787;\n  --deep-blue:#1a3a6e;--light-blue:#edf1f8;\n}\n.lm-topbar *, .lm-hero *, .lm-wrap *, .lm-footer *{box-sizing:border-box;margin:0;padding:0}\n.lm-topbar,.lm-hero,.lm-wrap,.lm-footer{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;background:var(--bg);color:var(--text);line-height:1.6}\n.lm-wrap{max-width:980px;margin:0 auto;padding:24px}\n.lm-topbar{position:sticky;top:0;left:0;right:0;z-index:103;background:var(--dark);color:#fff;padding:12px 24px;display:flex;justify-content:space-between;align-items:center;flex-wrap:wrap;gap:8px}\n.lm-topbar .lm-tel{color:var(--gold);font-weight:600}\n.lm-hero{position:relative;background:linear-gradient(180deg,rgba(30,24,18,0.50),rgba(30,24,18,0.72)),url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-sxyxlbjt-06.png') center\/cover no-repeat;color:#fff!important;padding:48px 24px;border-radius:0 0 24px 24px;margin-bottom:24px;box-shadow:inset 0 90px 120px -50px rgba(0,0,0,.6),inset 0 -90px 120px -50px rgba(0,0,0,.65)}\n.lm-hero h1.lm-hero-title{font-size:2.4rem!important;margin-bottom:12px;line-height:1.28;font-weight:800!important;color:#fff!important;text-shadow:0 2px 5px rgba(0,0,0,.7),0 4px 18px rgba(0,0,0,.8)!important;-webkit-text-stroke:.3px rgba(0,0,0,.4)!important}\n.lm-hero h1.lm-hero-title span{color:#c5a55a}\n.lm-hero .lm-meta{display:flex;flex-wrap:wrap;gap:16px;margin-top:16px;opacity:.97;font-size:14px;text-shadow:0 1px 6px rgba(0,0,0,.55)}\n.lm-hero .lm-chip{display:inline-block;background:rgba(0,0,0,.3);padding:4px 12px;border-radius:20px;font-size:13px;margin-right:8px;margin-bottom:8px;text-shadow:0 1px 4px rgba(0,0,0,.5);border:1px solid rgba(255,255,255,.3)}\n.lm-geo-card{background:var(--card);border-radius:16px;padding:20px;box-shadow:0 4px 20px rgba(0,0,0,.06);margin-bottom:24px}\n.lm-geo-card h3{color:var(--dark);font-size:16px;margin-bottom:12px;display:flex;align-items:center;gap:8px}\n.lm-geo-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:12px}\n.lm-geo-item{display:flex;align-items:flex-start;gap:10px}\n.lm-geo-item .lm-icon{font-size:20px;width:28px;text-align:center}\n.lm-geo-item .lm-label{font-size:12px;color:var(--muted)}\n.lm-geo-item .lm-value{font-size:15px;font-weight:600;color:var(--text)}\n.lm-geo-flip{position:relative;margin-top:2px}\n.lm-geo-flip-toggle{position:absolute;width:1px;height:1px;opacity:0;overflow:hidden}\n.lm-geo-flip-card{display:block;cursor:pointer;perspective:1400px;-webkit-tap-highlight-color:transparent}\n.lm-geo-flip-inner{display:grid;transform-style:preserve-3d;transition:transform .65s cubic-bezier(.4,.2,.2,1)}\n.lm-geo-flip-face{grid-area:1\/1;background:var(--light-blue);border:1px solid #dde4f0;border-radius:14px;padding:18px 18px 14px;backface-visibility:hidden;-webkit-backface-visibility:hidden;box-shadow:0 6px 18px rgba(26,58,110,.1)}\n.lm-geo-flip-back{transform:rotateY(180deg)}\n.lm-geo-flip-toggle:checked ~ .lm-geo-flip-card .lm-geo-flip-inner{transform:rotateY(180deg)}\n.lm-geo-flip-h{font-size:13px;font-weight:700;color:var(--deep-blue);margin-bottom:10px;display:flex;align-items:center;gap:6px;padding-bottom:8px;border-bottom:1px dashed #d4dcec}\n.lm-geo-flip-item{display:flex;align-items:flex-start;gap:10px;padding:10px 0;border-bottom:1px solid #e8eef6}\n.lm-geo-flip-item:last-child{border-bottom:none}\n.lm-geo-flip-item .lm-icon{font-size:19px;width:26px;text-align:center;flex:0 0 26px;line-height:1.5}\n.lm-geo-flip-item .lm-label{font-size:12px;color:var(--muted)}\n.lm-geo-flip-item .lm-value{font-size:14px;font-weight:600;color:var(--text);line-height:1.4}\n.lm-geo-flip-tip{margin-top:12px;text-align:center;font-size:12px;color:var(--blue);background:#f0f4f5;border-radius:20px;padding:8px 14px}\n.lm-geo-flip-toggle:focus-visible ~ .lm-geo-flip-card{outline:2px solid var(--deep-blue);outline-offset:3px;border-radius:14px}\n.lm-s1-info-tbl{font-size:12.5px;margin:2px 0 0}\n.lm-s1-info-tbl td,.lm-s1-info-tbl th{padding:7px 9px;line-height:1.45}\n.lm-s1-goal-lead{font-size:13.5px;line-height:1.75;color:var(--text);margin:0 0 12px}\n.lm-s1-flip-hint{font-size:13px;color:var(--muted);margin:0 0 14px}\n.lm-section{background:var(--card);border-radius:16px;padding:24px;margin-bottom:24px;box-shadow:0 2px 12px rgba(0,0,0,.05)}\n.lm-section h2{font-size:20px;color:var(--dark);margin-bottom:16px;padding-bottom:10px;border-bottom:2px solid var(--deep-blue);display:inline-block}\n.lm-section h3{font-size:16px;color:var(--dark);margin:20px 0 12px}\n.lm-sec-label{font-size:12px;color:var(--deep-blue);font-weight:700;text-transform:uppercase;letter-spacing:1px;margin-bottom:4px}\n.lm-tbl{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px}\n.lm-tbl th,.lm-tbl td{padding:10px 12px;border:1px solid #dde4f0;text-align:left}\n.lm-tbl th{background:#edf1f8;font-weight:600;color:var(--deep-blue)}\n.lm-tbl tr:nth-child(even) td{background:#f5f8fc}\n.lm-tbl td.lm-num,.lm-tbl th.lm-num{text-align:center}\n.lm-tbl td.lm-hi,.lm-tbl th.lm-hi{color:var(--deep-blue);font-weight:700}\n.lm-tbl td.lm-pr{color:var(--blue);font-weight:600;font-family:monospace}\n.lm-note{border-left:4px solid var(--deep-blue);background:#eef3fb;padding:12px 16px;margin:12px 0;border-radius:0 8px 8px 0;font-size:14px}\n.lm-note.lm-nb{border-left-color:var(--blue);background:#f0f4f5}\n.lm-note.lm-ng{border-left-color:var(--green);background:#f2f7f2}\n.lm-card-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:16px;margin:16px 0}\n.lm-card{border:1px solid #dde4f0;border-radius:12px;padding:16px;position:relative;overflow:hidden}\n.lm-card.lm-edge-o{border-left:4px solid var(--deep-blue)}\n.lm-card.lm-edge-b{border-left:4px solid var(--blue)}\n.lm-card.lm-edge-g{border-left:4px solid var(--green)}\n.lm-card.lm-edge-gold{border-left:4px solid var(--gold)}\n.lm-card .lm-tag{position:absolute;top:12px;right:12px;background:var(--deep-blue);color:#fff;font-size:11px;padding:2px 8px;border-radius:10px}\n.lm-card .lm-tag.lm-blue{background:var(--blue)}\n.lm-card .lm-tag.lm-green{background:var(--green)}\n.lm-card .lm-tag.lm-gold{background:var(--gold)}\n.lm-card h4{font-size:16px;margin-bottom:8px;color:var(--dark)}\n.lm-card .lm-price{font-size:22px;color:var(--blue);font-weight:700;margin:8px 0}\n.lm-card .lm-price span{font-size:13px;color:var(--muted);font-weight:400}\n.lm-matrix{display:grid;grid-template-columns:repeat(auto-fit,minmax(120px,1fr));gap:10px;margin:16px 0}\n.lm-matrix .lm-cell{background:#f5f8fc;border:1px solid #dde4f0;border-radius:8px;padding:10px;text-align:center;font-size:13px}\n.lm-matrix .lm-cell.lm-head{background:var(--deep-blue);color:#fff;font-weight:600}\n.lm-matrix .lm-cell.lm-hi{background:#edf1f8;color:var(--deep-blue);font-weight:700}\n.lm-comparison-table{width:100%;border-collapse:collapse;margin:16px 0;font-size:14px}\n.lm-comparison-table th,.lm-comparison-table td{padding:12px;border:1px solid #dde4f0;text-align:center}\n.lm-comparison-table th{background:var(--deep-blue);color:#fff}\n.lm-comparison-table td:first-child{text-align:left;font-weight:600}\n.lm-comparison-table tr:nth-child(even) td{background:#f5f8fc}\n.lm-stars{color:var(--gold);letter-spacing:2px}\n.lm-radar-wrap{text-align:center;margin:8px 0 4px}\n.lm-radar-cap{font-size:13px;color:var(--muted);line-height:1.7;margin:12px 0 4px;padding:12px 16px;background:#f5f8fc;border:1px solid #dde4f0;border-radius:10px}\n.lm-radar-cap b{color:var(--dark)}\n.lm-footer{background:var(--dark);color:#fff;padding:32px 24px;border-radius:24px 24px 0 0;margin-top:24px;text-align:center}\n.lm-footer .lm-motto{font-size:18px;font-weight:600;margin-bottom:8px}\n.lm-footer .lm-icp{font-size:12px;opacity:.8;margin-top:12px}\nul.lm-check{list-style:none;margin:8px 0}\nul.lm-check li{padding:6px 0;padding-left:24px;position:relative;font-size:14px}\nul.lm-check li::before{content:\"\u2713\";position:absolute;left:0;color:var(--green);font-weight:700}\n.lm-confirm{background:#f2f7f2;border:1px dashed var(--green);border-radius:10px;padding:14px 16px;margin:16px 0;font-size:14px;color:#2d5a2d}\n.lm-gallery{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:12px;margin:14px 0}\n.lm-gallery figure{margin:0;background:#f5f8fc;border:1px solid #dde4f0;border-radius:10px;overflow:hidden}\n.lm-gallery img{width:100%;height:auto;display:block}\n.lm-gallery figcaption{font-size:12px;color:var(--muted);padding:8px 10px;line-height:1.45}\n\/* S4 \u7a7a\u8c03\u7cbe\u5de5\u65bd\u5de5\u5b9e\u666f\u56fe\u96c6 \u00b7 \u7edf\u4e00\u7f8e\u89c2\u5361\u7247\uff08\u4ec5\u4f5c\u7528\u4e8e S4\uff09 *\/\n.lm-gallery-ac{grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:14px;margin:14px 0}\n.lm-gallery-ac figure{background:#fff;border:1px solid #e7ecf3;border-radius:12px;box-shadow:0 2px 10px rgba(26,58,110,.08);overflow:hidden;transition:transform .25s ease,box-shadow .25s ease}\n.lm-gallery-ac figure:hover{transform:translateY(-4px);box-shadow:0 10px 24px rgba(26,58,110,.18)}\n.lm-gallery-ac img{width:100%;aspect-ratio:4\/3;height:auto;object-fit:cover;background:#eef2f7;display:block}\n.lm-gallery-ac figcaption{padding:9px 11px;color:var(--muted);line-height:1.45;border-top:1px solid #f1f4f9}\n.lm-faq details{border:1px solid #dde4f0;border-radius:10px;margin:10px 0;background:#fff;overflow:hidden}\n.lm-faq details summary{cursor:pointer;padding:14px 16px 14px 44px;font-weight:600;color:var(--deep-blue);list-style:none;position:relative}\n.lm-faq details summary::-webkit-details-marker{display:none}\n.lm-faq details summary::before{content:\"\u25b8\";position:absolute;left:16px;top:14px;font-size:.8rem;color:var(--muted);transition:transform .2s}\n.lm-faq details[open] summary::before{content:\"\u25be\"}\n.lm-faq details[open] summary{border-bottom:1px solid #eef1f7}\n.lm-faq details .lm-faq-a{padding:2px 16px 16px 44px;font-size:14px;line-height:1.75;color:var(--text)}\n.lm-sub-h{font-size:15px;color:var(--dark);margin:18px 0 10px;padding-left:10px;border-left:3px solid var(--green)}\n.lm-gallery-title{font-size:15px;color:var(--dark);font-weight:600;margin:18px 0 4px}\n\/* ===== \u4e24\u7ea7\u6298\u53e0\u5bfc\u822a\uff08\uff09\uff1a\u4e3b\u5bfc\u822a\u5438\u9876\u5e38\u9a7b\uff0c\u70b9 S \u5c55\u5f00\u5b50\u9879\uff08\u7eafCSS\uff0c\u96f6JS\uff0c\u9632WP\u51b2\u7a81\uff09 ===== *\/\n.lm-toc{position:sticky;top:48px;left:0;right:0;max-width:980px;margin:0 auto;z-index:102;background:var(--deep-blue);box-shadow:0 2px 10px rgba(26,58,110,.2);\n  display:flex;flex-wrap:wrap;gap:3px;padding:4px 12px;overflow:visible}\n.lm-toc > a{display:inline-flex;align-items:center;color:#fff;font-size:.72rem;font-weight:600;background:rgba(255,255,255,.12);padding:3px 10px;border-radius:999px;white-space:nowrap;text-decoration:none;user-select:none}\n.lm-toc > a:hover{background:rgba(255,255,255,.24)}\n.lm-toc > .lm-toc-item{position:relative;flex:0 0 auto}\n.lm-toc > .lm-toc-item > summary{list-style:none;cursor:pointer;display:inline-flex;align-items:center;padding:3px 10px;border-radius:999px;\n  color:#fff;font-size:.72rem;font-weight:600;background:rgba(255,255,255,.12);user-select:none;white-space:nowrap}\n.lm-toc > .lm-toc-item > summary::-webkit-details-marker{display:none}\n.lm-toc > .lm-toc-item > summary::after{content:\" \u25be\";font-size:.62rem;opacity:.8;margin-left:4px}\n.lm-toc > .lm-toc-item[open] > summary::after{content:\" \u25b4\"}\n.lm-toc > .lm-toc-item[open] > summary{background:rgba(255,255,255,.24)}\n.lm-toc-item > .lm-toc-drop{position:absolute;top:calc(100% + 6px);left:0;margin:0;min-width:210px;background:#fff;\n  border:1px solid #dde4f0;border-radius:10px;box-shadow:0 10px 30px rgba(26,58,110,.18);padding:6px;\n  display:none;flex-direction:column;z-index:110}\n.lm-toc-item[open] > .lm-toc-drop{display:flex}\n.lm-toc-item:last-child > .lm-toc-drop{left:auto;right:0}\n.lm-toc-drop a{display:block;padding:8px 12px;border-radius:7px;color:var(--deep-blue);text-decoration:none;font-size:.82rem;line-height:1.3;white-space:nowrap}\n.lm-toc-drop a:hover{background:var(--light-blue);color:var(--deep-blue)}\n\/* \u951a\u70b9\u8df3\u8f6c\u4e0d\u88ab\u56fa\u5b9a\u5bfc\u822a\u906e\u6321\uff08\u542b\u5b50\u6807\u9898\uff09 *\/\n.lm-section,.lm-geo-card{scroll-margin-top:92px}\n\/* ===== \u5dee\u5f02\u5316\u6807\u7b7e + \u5185\u90e8\u56de\u6d41\u5757\uff08 \uff09 ===== *\/\n.lm-tags{display:flex;flex-wrap:wrap;gap:10px;max-width:980px;margin:0 auto;padding:0 24px 8px}\n.lm-difftag{display:inline-block;padding:7px 16px;border-radius:999px;font-size:13px;font-weight:700;color:#fff;background:linear-gradient(135deg,var(--deep-blue),#2a4a82);box-shadow:0 2px 8px rgba(26,58,110,.22)}\n.lm-difftag.is-gold{background:linear-gradient(135deg,var(--gold),#b08d3f);color:#1a1408}\n\/* \u6848\u4f8b\u4fe1\u606f\u5361\uff08S1 \u4e0a\u65b9\uff09 *\/\n.lm-geo-info{display:flex;flex-wrap:wrap;gap:8px 18px;max-width:980px;margin:14px auto 0;padding:12px 18px;background:linear-gradient(135deg,#1a3a6e,#2a4a82);border-radius:12px;color:#fff;font-size:13.5px;line-height:1.6}\n.lm-geo-info-item{white-space:nowrap}\n.lm-geo-info-item b{color:#e9c97a}\n\/* \u7126\u70b9\u5173\u952e\u8bcd\u5757\uff08\u6848\u4f8b\u4fe1\u606f\u5361\u4e0b\u65b9\uff09 *\/\n.lm-keywords{display:flex;flex-wrap:wrap;align-items:center;gap:9px;max-width:980px;margin:10px auto 0;padding:0 24px}\n.lm-kw-title{font-weight:700;color:var(--deep-blue);font-size:13px}\n.lm-kw{display:inline-block;padding:5px 12px;border-radius:999px;font-size:12.5px;color:var(--deep-blue);background:#eef2f8;border:1px solid #dde4f0;text-decoration:none;transition:.2s}\n.lm-kw:hover{background:var(--deep-blue);color:#fff}\n.lm-backflow{background:linear-gradient(180deg,#f3f6fb,#eaf0f8);border:1px solid #dde4f0}\n.lm-bf-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:12px;margin:14px 0}\n.lm-bf-link{display:block;padding:14px 16px;border-radius:12px;background:#fff;border:1px solid #dde4f0;color:var(--deep-blue);font-weight:600;font-size:14px;text-decoration:none;box-shadow:0 2px 8px rgba(26,58,110,.08);transition:.2s}\n.lm-bf-link:hover{background:var(--deep-blue);color:#fff}\n.lm-bf-meta{font-size:13.5px;color:var(--text);background:#fff;border:1px dashed var(--deep-blue);border-radius:10px;padding:12px 16px;line-height:1.8}\n<\/style>\n\n<div class=\"lm-topbar\">\n  <div>\u9f99\u8109\u6696\u901a \u00b7 \u6848\u4f8b\u4e2d\u5fc3<\/div>\n  <div>\u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7 \ud83d\udcde <a href=\"tel:15828489188\">15828489188<\/a><\/div>\n<\/div>\n\n<div class=\"lm-hero\">\n  <div class=\"lm-wrap\">\n    <span class=\"lm-chip\">\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6<\/span>\n    <span class=\"lm-chip\">\u8212\u4eab200\u4e00\u62d6\u516d<\/span>\n    <span class=\"lm-chip\">\u51b7\u51dd\u7089\u5730\u66969\u56de\u8def<\/span>\n    <span class=\"lm-chip\">\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/span>\n    <h2 class=\"lm-hero-title\">\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-<span>\u9f99\u8109\u6696\u901a<\/span><\/h2>\n    <div class=\"lm-meta\">\n      <div>\ud83d\udccd \u6210\u90fd \u00b7 \u90eb\u90fd\u533a \u00b7 \u897f\u534e\u82d1\u4e09\u671f<\/div>\n      <div>\ud83c\udfe0 \u4e09\u5ba4\u4e24\u5385 \u00b7 \u5efa\u9762132\u33a1<\/div>\n      <div>\u2744\ufe0f \u65e5\u7acb\u8212\u4eab200 \u00b7 \u4e00\u62d6\u516d<\/div>\n      <div>\ud83d\udd25 \u66fc\u745e\u5fb7\u51b7\u51dd\u7089 \u00b7 9\u56de\u8def\u5730\u6696<\/div>\n      <div>\ud83c\udf00 \u65e5\u7acb\u4e91\u955c252 \u00b7 \u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/div>\n      <div>\u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7 \ud83d\udcde <a href=\"tel:15828489188\">15828489188<\/a><\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n  <!-- \u5dee\u5f02\u5316\u6807\u7b7e -->\n  <div class=\"lm-tags\">\n    <span class=\"lm-difftag\">\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6<\/span>\n    <span class=\"lm-difftag\">\u8212\u4eab200\u4e00\u62d6\u516d<\/span>\n    <span class=\"lm-difftag\">\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696<\/span>\n    <span class=\"lm-difftag is-gold\">\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/span>\n  <\/div>\n\n<!-- \u5f53\u6d4f\u89c8\u5668\u7981\u7528JS\u65f6\u7684\u4fe1\u606f\u515c\u5e95\uff08\u7eaf\u6587\u672c\uff0c\u4e0d\u5f71\u54cd\u96f6JS\u8bbe\u8ba1\uff09 -->\n<noscript>\n  <div class=\"lm-geo-info\" style=\"margin:14px auto 0\">\n    <span class=\"lm-geo-info-item\">\ud83d\udccd <b>\u6210\u90fd\u00b7\u90eb\u90fd\u533a<\/b>\u00b7\u897f\u534e\u82d1\u4e09\u671f<\/span>\n    <span class=\"lm-geo-info-item\">\ud83c\udfe0 \u4e09\u5ba4\u4e24\u5385 \u00b7 \u5efa\u9762132\u33a1<\/span>\n    <span class=\"lm-geo-info-item\">\u2744\ufe0f \u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u51b7\u51dd\u7089\u5730\u6696+\u4e91\u955c\u65b0\u98ce<\/span>\n    <span class=\"lm-geo-info-item\">\u2705 \u5df2\u7b7e\u5355\uff082026-07-16\uff09<\/span>\n    <span class=\"lm-geo-info-item\">\ud83d\udef0\ufe0f \u65bd\u5de5\u8986\u76d6\uff1a\u6210\u90fd\u5168\u57df12\u533a<\/span>\n    <span class=\"lm-geo-info-item\">\ud83d\udd52 \u66f4\u65b0\u65f6\u95f4\uff1a2026-08-18<\/span>\n    <span class=\"lm-geo-info-item\">\ud83d\udc64 \u6848\u4f8b\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7<\/span>\n  <\/div>\n<\/noscript>\n\n<div class=\"lm-wrap\">\n\n  <!-- \u4e24\u7ea7\u6298\u53e0\u5bfc\u822a\uff1a\u4e3b\u5bfc\u822a\u5438\u9876\u5e38\u9a7b\uff0c\u70b9 S \u5c55\u5f00\u5b50\u9879\uff08\u7eafCSS \u4e24\u7ea7\u6298\u53e0\uff0c\u96f6JS\uff0c\u4e0eWP\u4e3b\u9898\u65e0\u51b2\u7a81\uff09 -->\n  <nav class=\"lm-toc\">\n    <a href=\"#s1\">S1 \u00b7 \u65b9\u6848\u76ee\u6807<\/a>\n    <a href=\"#s2\">S2 \u00b7 \u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad<\/a>\n    <details class=\"lm-toc-item\" name=\"lmsec\">\n      <summary>S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e<\/summary>\n      <div class=\"lm-toc-drop\">\n        <a href=\"#s3\" class=\"lm-drop-sec\">S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e<\/a>\n        <a href=\"#s3-value\">\u516d\u6838\u5fc3\u4ef7\u503c<\/a>\n        <a href=\"#s3-arch\">\u7cfb\u7edf\u67b6\u6784<\/a>\n        <a href=\"#s3-weak\" class=\"lm-drop-hi\">\u65b9\u6848\u52a3\u52bf<\/a>\n      <\/div>\n    <\/details>\n    <details class=\"lm-toc-item\" name=\"lmsec\">\n      <summary>S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u4fdd\u969c<\/summary>\n      <div class=\"lm-toc-drop\">\n        <a href=\"#s4\" class=\"lm-drop-sec\">S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u4fdd\u969c<\/a>\n        <a href=\"#s4-process\">\u7cbe\u5de5\u516d\u6b65\u6cd5<\/a>\n        <a href=\"#s4-gallery\">\u65bd\u5de5\u5b9e\u666f<\/a>\n        <a href=\"#s4-warranty\">\u670d\u52a1\u4fdd\u969c<\/a>\n      <\/div>\n    <\/details>\n    <details class=\"lm-toc-item\" name=\"lmsec\">\n      <summary>S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/summary>\n      <div class=\"lm-toc-drop\">\n        <a href=\"#s5\" class=\"lm-drop-sec\">S5 \u00b7 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/a>\n        <a href=\"#s5-diag\">\u914d\u7f6e\u8bca\u65ad<\/a>\n        <a href=\"#s5-dims\" class=\"lm-drop-hi\">\u516d\u7ef4\u5bf9\u6bd4<\/a>\n        <a href=\"#s5-ledger\" class=\"lm-drop-hi\">20\u5e74\u603b\u8d26<\/a>\n      <\/div>\n    <\/details>\n    <details class=\"lm-toc-item\" name=\"lmsec\">\n      <summary>\u66f4\u591a\u4e86\u89e3<\/summary>\n      <div class=\"lm-toc-drop\">\n        <a href=\"#s6\">\u9ad8\u9891\u95ee\u9898<\/a>\n        <a href=\"#s7\" class=\"lm-drop-hi\">\u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97<\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u5e93<\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=5849\">\u6210\u90fd\u6237\u578b\u65b9\u6848\u5e93<\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\">\u5730\u6696\u4e13\u9879\u6848\u4f8b<\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=3147\">\u6bcf\u65e5\u65b0\u6848\u4f8b\u805a\u5408<\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=3023\">\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/a>\n      <\/div>\n    <\/details>\n  <\/nav>\n\n  <!-- \u6848\u4f8b\u4fe1\u606f\u5361\uff08S1 \u65b9\u6848\u76ee\u6807\u4e0a\u65b9\uff09 -->\n  <div class=\"lm-geo-info\" id=\"geo-info\">\n    <span class=\"lm-geo-info-item\">\ud83d\udccd <b>\u6210\u90fd\u00b7\u90eb\u90fd\u533a<\/b>\u00b7\u897f\u534e\u82d1\u4e09\u671f<\/span>\n    <span class=\"lm-geo-info-item\">\ud83c\udfe0 \u4e09\u5ba4\u4e24\u5385 \u00b7 \u5efa\u9762132\u33a1<\/span>\n    <span class=\"lm-geo-info-item\">\u2744\ufe0f \u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce<\/span>\n    <span class=\"lm-geo-info-item\">\u2705 \u5df2\u7b7e\u5355\uff082026-07-16\uff09<\/span>\n    <span class=\"lm-geo-info-item\">\ud83c\udfc6 \u5dee\u5f02\u5316\uff1a\u4e09\u7cfb\u7edf\u534f\u540c\u00b7\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e00\u6b21\u5230\u4f4d<\/span>\n    <span class=\"lm-geo-info-item\">\ud83d\udef0\ufe0f \u65bd\u5de5\u8986\u76d6\uff1a\u6210\u90fd\u5168\u57df12\u533a\uff08\u9526\u6c5f\u3001\u9752\u7f8a\u3001\u6b66\u4faf\u3001\u6210\u534e\u3001\u90eb\u90fd\u3001\u6e29\u6c5f\u7b49\uff09<\/span>\n    <span class=\"lm-geo-info-item\">\ud83d\udd52 \u66f4\u65b0\u65f6\u95f4\uff1a2026-08-18<\/span>\n    <span class=\"lm-geo-info-item\">\ud83d\udc64 \u6848\u4f8b\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7<\/span>\n  <\/div>\n\n  <!-- \u7126\u70b9\u5173\u952e\u8bcd\u5757\uff08\u6848\u4f8b\u4fe1\u606f\u5361\u4e0b\u65b9\uff09 -->\n  <div class=\"lm-keywords\" id=\"kw\">\n    <span class=\"lm-kw-title\">\ud83d\udd11 \u7126\u70b9\u5173\u952e\u8bcd<\/span>\n    <a class=\"lm-kw\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener\">\u6210\u90fd\u897f\u534e\u82d1\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b<\/a>\n    <span class=\"lm-kw\">\u8212\u4eab200\u4e00\u62d6\u516d<\/span>\n    <span class=\"lm-kw\">\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696<\/span>\n    <span class=\"lm-kw\">\u65e5\u7acb\u4e91\u955c\u65b0\u98ce<\/span>\n    <span class=\"lm-kw\">132\u33a1\u4e09\u5ba4\u4e24\u5385<\/span>\n    <span class=\"lm-kw\">\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u4e09\u7cfb\u7edf<\/span>\n    <span class=\"lm-kw\">\u6210\u90fd\u514d\u8d39\u52d8\u6d4b<\/span>\n  <\/div>\n\n  <!-- \u9996\u5c4f \u6848\u4f8b\u4fe1\u606f\u5361\uff08\u7ffb\u8f6c\uff09 -->\n  <div class=\"lm-geo-card\" id=\"geo\">\n    <h3>\ud83d\udccb \u9879\u76ee\u901f\u89c8\u5361<\/h3>\n    <div class=\"lm-geo-flip\">\n      <input class=\"lm-geo-flip-toggle\" type=\"checkbox\" id=\"geoFlip\" aria-label=\"\u7ffb\u8f6c\u9879\u76ee\u901f\u89c8\u5361\u67e5\u770b\u53e6\u4e00\u9762\">\n      <label class=\"lm-geo-flip-card\" for=\"geoFlip\">\n        <div class=\"lm-geo-flip-inner\">\n          <div class=\"lm-geo-flip-face lm-geo-flip-front\">\n            <div class=\"lm-geo-flip-h\">\ud83c\udff7\ufe0f \u9879\u76ee\u753b\u50cf<\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83d\udc64<\/span><div><div class=\"lm-label\">\u4e1a\u4e3b<\/div><div class=\"lm-value\">\u4e54\u8001\u5e08 \u00b7 \u897f\u534e\u82d1\u4e09\u671f<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83c\udfe0<\/span><div><div class=\"lm-label\">\u6237\u578b\u4e0e\u4eba\u6570<\/div><div class=\"lm-value\">\u4e09\u5ba4\u4e24\u5385 \u00b7 \u5efa\u9762132\u33a1 \u00b7 \u591a\u623f\u95f4\u72ec\u7acb\u63a7\u6e29<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\u2744\ufe0f<\/span><div><div class=\"lm-label\">\u7a7a\u8c03\u914d\u7f6e<\/div><div class=\"lm-value\">\u4e00\u62d6\u516d \u00b7 \u65e5\u7acb\u8212\u4eab200\u578b\u53cc\u98ce\u6247<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83d\udd25<\/span><div><div class=\"lm-label\">\u5730\u6696\u914d\u7f6e<\/div><div class=\"lm-value\">\u66fc\u745e\u5fb7\u5c0f\u536124kW\u51b7\u51dd\u7089 \u00b7 9\u56de\u8def<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83c\udf00<\/span><div><div class=\"lm-label\">\u65b0\u98ce\u914d\u7f6e<\/div><div class=\"lm-value\">\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u5668<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83c\udfea<\/span><div><div class=\"lm-label\">\u95e8\u5e97\u89e6\u70b9<\/div><div class=\"lm-value\">\u5317\u5bcc\u68ee(\u6210\u534e\u00b7<a href=\"tel:02865272586\">028-65272586<\/a>) \u00b7 \u5357\u5bcc\u68ee(\u9ad8\u65b0\u00b7<a href=\"tel:02886131795\">028-86131795<\/a>)<\/div><\/div><\/div>\n          <\/div>\n          <div class=\"lm-geo-flip-face lm-geo-flip-back\">\n            <div class=\"lm-geo-flip-h\">\u2699\ufe0f \u65b9\u6848\u8981\u70b9<\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\u2744\ufe0f<\/span><div><div class=\"lm-label\">\u7a7a\u8c03<\/div><div class=\"lm-value\">\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d \u00b7 \u5168\u5c4b\u5236\u51b7\u5236\u70ed<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83d\udd25<\/span><div><div class=\"lm-label\">\u5730\u6696<\/div><div class=\"lm-value\">\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+9\u56de\u8def \u00b7 \u51ac\u5b63\u91c7\u6696<\/div><\/div><\/div>\n            <div class=\"lm-geo-flip-item\"><span class=\"lm-icon\">\ud83c\udf00<\/span><div><div class=\"lm-label\">\u65b0\u98ce<\/div><div class=\"lm-value\">\u65e5\u7acb\u4e91\u955c252 \u00b7 \u5168\u70ed\u4ea4\u6362\u51c0\u5316<\/div><\/div><\/div>\n          <\/div>\n        <\/div>\n        <div class=\"lm-geo-flip-tip\">\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\uff0c\u67e5\u770b\u53e6\u5916 3 \u9879<\/div>\n      <\/label>\n    <\/div>\n  <\/div>\n\n  <!-- S1 \u65b9\u6848\u76ee\u6807 -->\n  <section class=\"lm-section\" id=\"s1\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S1<\/div>\n    <h2>\u65b9\u6848\u76ee\u6807<\/h2>\n    <p class=\"lm-s1-flip-hint\">\ud83d\udc46 \u4e0b\u9762\u662f\u4e00\u5f20\u53ef\u7ffb\u8f6c\u5361\u7247\uff1a<strong>\u6b63\u9762\uff1d\u9879\u76ee\u57fa\u7840\u4fe1\u606f<\/strong>\uff0c<strong>\u80cc\u9762\uff1d\u65b9\u6848\u76ee\u6807<\/strong>\uff0c\u70b9\u51fb\u5361\u7247\u5373\u53ef\u7ffb\u8f6c\u67e5\u770b\u3002<\/p>\n    <div class=\"lm-geo-flip\" id=\"s1-info\">\n      <input class=\"lm-geo-flip-toggle\" type=\"checkbox\" id=\"s1Flip\" aria-label=\"\u7ffb\u8f6c\u67e5\u770b\u65b9\u6848\u76ee\u6807\">\n      <label class=\"lm-geo-flip-card\" for=\"s1Flip\">\n        <div class=\"lm-geo-flip-inner\">\n          <div class=\"lm-geo-flip-face lm-geo-flip-front\">\n            <div class=\"lm-geo-flip-h\">\ud83c\udff7\ufe0f \u9879\u76ee\u57fa\u7840\u4fe1\u606f\uff08\u6b63\u9762\uff09<\/div>\n            <table class=\"lm-tbl lm-s1-info-tbl\">\n              <tr><th>\u5c0f\u533a<\/th><td>\u897f\u534e\u82d1\u4e09\u671f<\/td><\/tr>\n              <tr><th>\u6237\u578b\/\u9762\u79ef<\/th><td>\u4e09\u5ba4\u4e24\u5385 \u00b7 \u5efa\u9762132\u33a1\uff08\u8212\u9002\u578b\uff09<\/td><\/tr>\n              <tr><th>\u7cfb\u7edf<\/th><td>\u65e5\u7acb\u8212\u4eab200 \u4e00\u62d6\u516d + \u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696 + \u65e5\u7acb\u4e91\u955c\u65b0\u98ce<\/td><\/tr>\n              <tr><th>\u7a7a\u8c03<\/th><td>\u8212\u4eab\u53cc\u98ce\u6247200\u578b\u5916\u673a \u00d71 + \u5185\u673a6\u53f0\uff0871+56 \/ 56 \/ 22 \/ 18 \/ 18\uff09<\/td><\/tr>\n              <tr><th>\u5730\u6696<\/th><td>\u66fc\u745e\u5fb7\u5c0f\u536124kW\u51b7\u51dd\u7089 \u00b7 9\u56de\u8def \u00b7 \u4f1f\u661f20\u76d8\u7ba1<\/td><\/tr>\n              <tr><th>\u65b0\u98ce<\/th><td>\u65e5\u7acb\u4e91\u955c\u4e8c\u7cfb\u5217252\u5168\u70ed\u4ea4\u6362\u5668 \u00d71<\/td><\/tr>\n              <tr><th>\u63a7\u5236<\/th><td>WiFi\u7ebf\u63a7\u5668\uff08\u5206\u533a\u57df\u6e29\u63a7\uff09<\/td><\/tr>\n              <tr><th>\u65bd\u5de5\u65b9<\/th><td>\u9f99\u8109\u6696\u901a\uff08\u65e5\u7acb\u94bb\u77f3\u6388\u6743\uff09<\/td><\/tr>\n              <tr><th>\u57ce\u5e02<\/th><td>\u6210\u90fd \u00b7 \u90eb\u90fd\u533a<\/td><\/tr>\n            <\/table>\n          <\/div>\n          <div class=\"lm-geo-flip-face lm-geo-flip-back\">\n            <div class=\"lm-geo-flip-h\">\ud83c\udfaf \u65b9\u6848\u76ee\u6807\uff08\u80cc\u9762\uff09<\/div>\n            <div class=\"lm-s1-goal-lead\">\u4e54\u8001\u5e08\u5bb6\u662f132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u6838\u5fc3\u8bc9\u6c42\u5f88\u660e\u786e\uff1a<strong>\u5168\u5c4b\u4e2d\u592e\u7a7a\u8c03\u8212\u9002\u5236\u51b7\u5236\u70ed\u3001\u51ac\u5b63\u6709\u5730\u6696\u91c7\u6696\u3001\u5168\u5e74\u6709\u6d01\u51c0\u65b0\u98ce<\/strong>\uff0c\u4e14\u4e09\u7cfb\u7edf\u8981\u4e00\u6b21\u8bbe\u8ba1\u4e00\u6b21\u65bd\u5de5\u3001\u4e92\u4e0d\u6253\u67b6\u3002\u6211\u4eec\u7684\u4e00\u62d6\u516d+\u51b7\u51dd\u7089\u5730\u6696+\u4e91\u955c\u65b0\u98ce\u65b9\u6848\u4ee5\u300c\u5206\u533a\u7cbe\u51c6\u63a7\u6e29 + \u51b7\u51dd\u9ad8\u6548\u91c7\u6696 + \u5168\u70ed\u4ea4\u6362\u51c0\u5316\u300d\u4e09\u4e2a\u52a8\u4f5c\u8fbe\u6210\u76ee\u6807\u3002<\/div>\n            <ul class=\"lm-check\">\n              <li>\u5168\u5c4b\u8212\u9002\uff1a\u4e00\u62d6\u516d\u8986\u76d6\u5ba2\u9910\u5385\u5230\u5404\u5367\u5ba4\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u6e29<\/li>\n              <li>\u51ac\u5b63\u6e29\u6696\uff1a\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\uff0c\u811a\u6696\u5934\u51c9\u66f4\u8212\u9002<\/li>\n              <li>\u7a7a\u6c14\u6d01\u51c0\uff1a\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u6362\u6c14\u4e0d\u6f0f\u6e29<\/li>\n              <li>\u9ad8\u6548\u7701\u6c14\uff1a\u51b7\u51dd\u7089\u56de\u6536\u4f59\u70ed + \u8054\u52a8\u63a7\u5236\uff0c\u91c7\u6696\u66f4\u7701<\/li>\n              <li>\u4e00\u6b21\u5230\u4f4d\uff1a\u4e09\u7cfb\u7edf\u534f\u540c\u8bbe\u8ba1\uff0c\u7ba1\u8def\u4e0e\u6e29\u63a7\u8054\u52a8\u534f\u8c03<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n        <div class=\"lm-geo-flip-tip\">\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\uff0c\u67e5\u770b\u65b9\u6848\u76ee\u6807<\/div>\n      <\/label>\n    <\/div>\n  <\/section>\n\n  <!-- S2 \u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad\u5206\u6790 -->\n  <section class=\"lm-section\" id=\"s2\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S2<\/div>\n    <h2>\u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad\u5206\u6790<\/h2>\n\n    <h3 id=\"s2-need\">\u2460 \u5ba2\u6237\u539f\u59cb\u9700\u6c42<\/h3>\n    <table class=\"lm-tbl\">\n      <tr><th style=\"width:35%\">\u5ba2\u6237\u8bc9\u6c42<\/th><th>\u8bca\u65ad\u4e0e\u89e3\u51b3\u65b9\u6848<\/th><\/tr>\n      <tr><td>\u4e09\u5ba4\u4e24\u5385\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u516d<\/td><td>\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\uff0c6\u53f0\u5185\u673a\u7cbe\u51c6\u5339\u914d\u4e94\u533a<\/td><\/tr>\n      <tr><td>\u51ac\u5b63\u8981\u6709\u5730\u6696\u91c7\u6696<\/td><td>\u66fc\u745e\u5fb7\u5c0f\u536124kW\u51b7\u51dd\u7089 + 9\u56de\u8def\u5730\u6696<\/td><\/tr>\n      <tr><td>\u5168\u5e74\u8981\u6709\u65b0\u98ce\u6362\u6c14<\/td><td>\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u6362\u6c14\u4e0d\u6f0f\u6e29<\/td><\/tr>\n      <tr><td>\u591a\u623f\u95f4\u72ec\u7acb\u63a7\u6e29<\/td><td>WiFi\u7ebf\u63a7\u5668\u5206\u533a\u57df\u6e29\u63a7\uff0c\u6309\u9700\u542f\u505c<\/td><\/tr>\n      <tr><td>\u4e09\u7cfb\u7edf\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5<\/td><td>\u9f99\u8109\u6574\u5305\uff0c\u7ba1\u8def\u4e0e\u6e29\u63a7\u8054\u52a8\u534f\u8c03<\/td><\/tr>\n    <\/table>\n\n    <h3 id=\"s2-hidden\">\u2461 \u9690\u85cf\u9700\u6c42\uff08\u8212\u9002\u578b\u4e09\u5ba4\u4e13\u5c5e\uff09<\/h3>\n    <ul class=\"lm-check\">\n      <li><strong>\u5ba2\u9910\u5385+\u53a8\u623f+\u9633\u53f0\u662f\u5927\u5f00\u95f4<\/strong>\uff1a67.32\u33a1\u8fde\u6210\u4e00\u7247\uff0c\u5355\u53f0\u5185\u673a\u9001\u4e0d\u5230\uff0c\u5fc5\u987b\u752871+56\u4e24\u53f0\u63a5\u529b\u624d\u80fd\u5747\u5300\u8986\u76d6\u3002<\/li>\n      <li><strong>\u51ac\u5b63\u91c7\u6696\u4f53\u9a8c\u8981\u6c42\u9ad8<\/strong>\uff1a\u6210\u90fd\u6e7f\u51b7\uff0c\u7a7a\u8c03\u5236\u70ed\u4f53\u611f\u4e0d\u5982\u5730\u6696\u811a\u6696\u5934\u51c9\uff1b\u51b7\u51dd\u7089\u6bd4\u5e38\u89c4\u7089\u66f4\u9ad8\u6548\u8212\u9002\u3002<\/li>\n      <li><strong>\u7a7a\u6c14\u8d28\u91cf\u654f\u611f<\/strong>\uff1a\u6210\u90fd\u79cb\u51ac\u96fe\u973e\u3001\u6625\u5b63\u82b1\u7c89\uff0c\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u5728\u6362\u6c14\u540c\u65f6\u8fc7\u6ee4PM2.5\uff0c\u5173\u95e8\u5173\u7a97\u4e5f\u6e05\u65b0\u3002<\/li>\n      <li><strong>\u957f\u671f\u6301\u6709\u7701\u5fc3<\/strong>\uff1a\u4e09\u7cfb\u7edf\u8054\u52a8+\u89c4\u8303\u65bd\u5de5+\u8282\u70b9\u5efa\u6863\uff0c\u540e\u671f\u8fd0\u7ef4\u4e0e\u8d28\u4fdd\u66f4\u7701\u5fc3\u3002<\/li>\n    <\/ul>\n\n    <h3 id=\"s2-load\">\u2462 \u7a7a\u8c03\u8d1f\u8377\u914d\u7f6e\uff08\u4e00\u62d6\u516d\uff09<\/h3>\n    <table class=\"lm-tbl\">\n      <tr><th>\u7a7a\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u578b\u53f7<\/th><th>\u5bb9\u91cf<\/th><th>\u51b7\u6307\u6807<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385+\u53a8\u623f+\u9633\u53f0<\/td><td>67.32\u33a1<\/td><td>RPIZ-71 + 56<\/td><td>\u5927\u4e09\u5339+2\u5339(12.7kW)<\/td><td>189W\/\u33a1<\/td><\/tr>\n      <tr><td>\u4e3b\u5367+\u8d77\u5c45\u5ba4<\/td><td>33.5\u33a1<\/td><td>RPIZ-56<\/td><td>2\u5339(5.6kW)<\/td><td>167W\/\u33a1<\/td><\/tr>\n      <tr><td>\u8863\u5e3d\u95f4<\/td><td>12.73\u33a1<\/td><td>RPIZ-22<\/td><td>0.8\u5339(2.2kW)<\/td><td>173W\/\u33a1<\/td><\/tr>\n      <tr><td>\u4e66\u623f<\/td><td>9.53\u33a1<\/td><td>RPIZ-18<\/td><td>0.7\u5339(1.8kW)<\/td><td>189W\/\u33a1<\/td><\/tr>\n      <tr><td>\u5065\u8eab\u623f<\/td><td>9.54\u33a1<\/td><td>RPIZ-18<\/td><td>0.7\u5339(1.8kW)<\/td><td>189W\/\u33a1<\/td><\/tr>\n      <tr><td colspan=\"5\" style=\"text-align:left;padding:10px;background:#eef2f7\">\u5916\u673a\uff1a<b>\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247200\u578b<\/b>\uff5c\u516d\u53f0\u5185\u673a\u5339\u914d\uff0c\u5355\u5f00\/\u5168\u5f00\u5747\u4ece\u5bb9\uff0c\u8fde\u63a5\u7387\u7b26\u540850%-130%\u89c4\u8303\u533a\u95f4<\/td><\/tr>\n    <\/table>\n\n    <h3 id=\"s2-compare\">\u2463 \u7cfb\u5217\u5173\u952e\u53c2\u6570\u5bf9\u6bd4\uff08\u8212\u4eab200\u53cc\u98ce\u6247 vs \u8212\u4eab\u5355\u98ce\u6247\uff09<\/h3>\n    <table class=\"lm-comparison-table\">\n      <tr><th>\u7ef4\u5ea6<\/th><th>\u8212\u4eab200 \u53cc\u98ce\u6247\uff08\u672c\u65b9\u6848\uff09<\/th><th>\u8212\u4eab\u5355\u98ce\u6247\uff08\u5c0f\u6237\u578b\u65b9\u6848\uff09<\/th><\/tr>\n      <tr><td>\u9002\u7528\u9762\u79ef<\/td><td>\u5927\u5e73\u5c42\/\u4e09\u5ba4\uff08\u7ea6130\u33a1\uff09\u2705<\/td><td>\u5c0f\u6237\u578b\uff08\u7ea676\u33a1\uff09<\/td><\/tr>\n      <tr><td>\u5916\u673a\u6563\u70ed<\/td><td>\u53cc\u98ce\u6247\uff0c\u9ad8\u6e29\u5de5\u51b5\u66f4\u7a33<\/td><td>\u5355\u98ce\u6247\uff0c\u7d27\u51d1<\/td><\/tr>\n      <tr><td>\u5185\u673a\u6570\u91cf<\/td><td>\u4e00\u62d6\u516d\u4ece\u5bb9<\/td><td>\u4e00\u62d6\u4e09<\/td><\/tr>\n      <tr><td>\u9884\u7b97<\/td><td>\u7565\u9ad8<\/td><td>\u66f4\u53cb\u597d<\/td><\/tr>\n    <\/table>\n    <div class=\"lm-note lm-nb\">\ud83d\udca1 <strong>\u9009\u578b\u903b\u8f91\uff1a<\/strong>\u4e54\u8001\u5e08\u5bb6132\u33a1\u4e09\u5ba4\u4e24\u5385\u3001\u5ba2\u9910\u5385\u5927\u5f00\u95f4\uff0c\u9700\u8981\u4e00\u62d6\u516d\u4e0e\u53cc\u98ce\u6247\u5927\u6563\u70ed\u9762\u79ef\u652f\u6491\uff1b\u53cc\u98ce\u6247\u8212\u4eab200\u5728\u300c\u8986\u76d6\u9762\u79ef + \u6781\u7aef\u5de5\u51b5\u7a33 + \u591a\u5185\u673a\u4ece\u5bb9\u300d\u4e0a\u66f4\u5951\u5408\uff0c\u5355\u98ce\u6247\u5c0f\u6237\u578b\u673a\u578b\u5728\u6b64\u573a\u666f\u5bb9\u91cf\u4e0d\u8db3\u3002<\/div>\n  <\/section>\n\n  <!-- S3 \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e -->\n  <section class=\"lm-section\" id=\"s3\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S3<\/div>\n    <h2>\u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e<\/h2>\n\n    <h3 id=\"s3-value\">\u2460 \u516d\u6838\u5fc3\u4ef7\u503c<\/h3>\n    <div class=\"lm-card-grid\">\n      <div class=\"lm-card lm-edge-o\"><span class=\"lm-tag\">\u4ef7\u503c1<\/span><h4>\u2744\ufe0f \u5168\u5c4b\u8212\u9002<\/h4><p>\u8212\u4eab200\u4e00\u62d6\u516d\u8986\u76d6\u4e94\u533a\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u6e29\uff0c\u5ba2\u9910\u5385\u5927\u5f00\u95f4\u5747\u5300\u9001\u51b7\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-b\"><span class=\"lm-tag lm-blue\">\u4ef7\u503c2<\/span><h4>\ud83d\udd25 \u51ac\u5b63\u6e29\u6696<\/h4><p>\u66fc\u745e\u5fb7\u5c0f\u536124kW\u51b7\u51dd\u7089+9\u56de\u8def\u5730\u6696\uff0c\u811a\u6696\u5934\u51c9\u66f4\u5065\u5eb7\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-g\"><span class=\"lm-tag lm-green\">\u4ef7\u503c3<\/span><h4>\ud83c\udf00 \u7a7a\u6c14\u6d01\u51c0<\/h4><p>\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u6362\u6c14\u540c\u65f6\u8fc7\u6ee4PM2.5\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-gold\"><span class=\"lm-tag lm-gold\">\u4ef7\u503c4<\/span><h4>\ud83d\udca1 \u9ad8\u6548\u7701\u6c14<\/h4><p>\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u4f59\u70ed+\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff0c\u91c7\u6696\u5b63\u66f4\u7701\u71c3\u6c14\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-o\"><span class=\"lm-tag\">\u4ef7\u503c5<\/span><h4>\ud83e\udde9 \u4e00\u6b21\u5230\u4f4d<\/h4><p>\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u534f\u540c\u8bbe\u8ba1\u65bd\u5de5\uff0c\u7ba1\u8def\u6e29\u63a7\u4e0d\u6253\u67b6\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-b\"><span class=\"lm-tag lm-blue\">\u4ef7\u503c6<\/span><h4>\ud83d\udcf1 \u667a\u63a7<\/h4><p>\u5206\u533a\u57dfWiFi\u7ebf\u63a7\u5668\uff0c\u4e09\u7cfb\u7edf\u6309\u9700\u542f\u505c\uff0c\u4f7f\u7528\u7701\u5fc3\u3002<\/p><\/div>\n    <\/div>\n\n    <h3 id=\"s3-arch\">\u2461 \u7cfb\u7edf\u67b6\u6784<\/h3>\n    <div class=\"lm-note\">\u672c\u6848\u4f8b\u4e3a<strong>\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03 + \u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696 + \u65e5\u7acb\u4e91\u955c\u65b0\u98ce<\/strong>\u4e09\u7cfb\u7edf\u534f\u540c\u65b9\u6848\uff1a1\u53f0\u8212\u4eab\u53cc\u98ce\u6247200\u578b\u5916\u673a\u62d66\u53f0\u98ce\u7ba1\u5f0f\u5185\u673a\uff08\u5ba2\u9910\u538571+56 \/ \u4e3b\u536756 \/ \u8863\u5e3d\u95f422 \/ \u4e66\u623f18 \/ \u5065\u8eab\u623f18\uff09\uff1b\u5730\u6696\u7531\u66fc\u745e\u5fb7\u5c0f\u536124kW\u51b7\u51dd\u7089\u4f9b\u70ed\u6c34\u81f39\u56de\u8def\u4f1f\u661f20\u76d8\u7ba1\uff0c\u914d\u767d\u91d1\u677f\u4fdd\u6e29\u4e0e32\u4e3b\u7ba1\uff1b\u65b0\u98ce\u4e3a\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u5668\u3002\u4e09\u7cfb\u7edf\u901a\u8fc7\u5206\u533a\u57dfWiFi\u6e29\u63a7\u4e0e\u8054\u52a8\u63a7\u5236\u7edf\u4e00\u8c03\u5ea6\u3002\u5177\u4f53\u8bbe\u5907\u62a5\u4ef7\u4ee5\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\u3002<\/div>\n    <div class=\"lm-matrix\">\n      <div class=\"lm-cell lm-head\">\u7a7a\u8c03<\/div><div class=\"lm-cell lm-head\">\u5730\u6696<\/div><div class=\"lm-cell lm-head\">\u65b0\u98ce<\/div><div class=\"lm-cell lm-head\">\u63a7\u5236<\/div>\n      <div class=\"lm-cell lm-hi\">\u8212\u4eab200\u4e00\u62d6\u516d<\/div>\n      <div class=\"lm-cell lm-hi\">\u66fc\u745e\u5fb724kW\u00b79\u56de\u8def<\/div>\n      <div class=\"lm-cell lm-hi\">\u4e91\u955c252\u5168\u70ed<\/div>\n      <div class=\"lm-cell lm-hi\">WiFi\u5206\u533a\u8054\u52a8<\/div>\n    <\/div>\n\n    <h3 id=\"s3-weak\" style=\"margin-top:20px;color:var(--deep-blue)\">\u65b9\u6848\u52a3\u52bf\u4e0e\u5766\u8bda\u63d0\u793a\uff08\u22653\u6761\uff09<\/h3>\n    <div class=\"lm-note lm-nb\">\ud83d\udca1 \u4efb\u4f55\u65b9\u6848\u90fd\u6709\u53d6\u820d\uff0c\u4ee5\u4e0b\u4e3a\u672c\u65b9\u6848\u9700\u8981\u60a8\u63d0\u524d\u77e5\u6653\u7684\u51e0\u70b9\u52a3\u52bf\uff1a<\/div>\n    <ul class=\"lm-check\">\n      <li><strong>\u521d\u6295\u9ad8\u4e8e\u5355\u7a7a\u8c03\uff1a<\/strong>\u4e09\u7cfb\u7edf\u6574\u4f53\u524d\u671f\u6295\u5165\u660e\u663e\u9ad8\u4e8e\u53ea\u88c5\u4e2d\u592e\u7a7a\u8c03\uff0c\u9884\u7b97\u6709\u9650\u65f6\u9700\u6743\u8861\u4f18\u5148\u7ea7\u3002<\/li>\n      <li><strong>\u65bd\u5de5\u9700\u7edf\u4e00\u534f\u8c03\uff1a<\/strong>\u7a7a\u8c03\u7ba1\u8def\u3001\u5730\u6696\u76d8\u7ba1\u3001\u65b0\u98ce\u98ce\u7ba1\u4ea4\u53c9\u4f5c\u4e1a\uff0c\u5fc5\u987b\u7edf\u4e00\u89c4\u5212\u70b9\u4f4d\u4e0e\u5de5\u671f\uff0c\u65bd\u5de5\u5468\u671f\u6bd4\u5355\u7cfb\u7edf\u66f4\u957f\u3002<\/li>\n      <li><strong>\u4f9d\u8d56\u89c4\u8303\u65bd\u5de5\uff1a<\/strong>\u94dc\u7ba1\u710a\u63a5\u3001\u6c2e\u6c14\u4fdd\u62a4\u3001\u4fdd\u538b\u9a8c\u6536\u3001\u5730\u6696\u4fdd\u538b\u4efb\u4e00\u73af\u8282\u4e0d\u8fbe\u6807\u90fd\u96be\u4ee5\u540e\u671f\u8865\u6551\uff0c\u5fc5\u987b\u9009\u62e9\u50cf\u9f99\u8109\u8fd9\u6837\u6709\u8282\u70b9\u5f52\u6863\u4e0e\u8d28\u4fdd\u7684\u65bd\u5de5\u65b9\u3002<\/li>\n      <li><strong>\u5730\u6696\u5360\u5c11\u91cf\u5c42\u9ad8\uff1a<\/strong>\u5730\u6696\u4fdd\u6e29\u5c42+\u56de\u586b\u7ea6\u5360\u75286-8cm\u5c42\u9ad8\uff0c\u5c42\u9ad8\u6781\u9650\u6237\u578b\u9700\u7cbe\u7b97\u3002<\/li>\n      <li><strong>\u65b0\u98ce\u9700\u9884\u7559\u98ce\u7ba1\uff1a<\/strong>\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u8981\u5728\u88c5\u4fee\u524d\u671f\u9884\u7559\u98ce\u7ba1\u901a\u9053\u4e0e\u4e3b\u673a\u4f4d\uff0c\u540e\u671f\u52a0\u88c5\u6210\u672c\u9ad8\u3002<\/li>\n    <\/ul>\n  <\/section>\n\n  <!-- S4 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c -->\n  <section class=\"lm-section\" id=\"s4\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S4<\/div>\n    <h2>\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c<\/h2>\n\n    <h3 id=\"s4-process\">\u2460 \u7cbe\u5de5\u516d\u6b65\u6cd5+2\uff08\u4e09\u7cfb\u7edf\u4ea4\u4ed8\u6807\u51c6\uff09<\/h3>\n    <table class=\"lm-tbl\">\n      <tr><th style=\"width:22%\">\u6b65\u9aa4<\/th><th>\u5185\u5bb9<\/th><\/tr>\n      <tr><td>\u2460 \u9700\u6c42\u52d8\u6d4b<\/td><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u51b7\u70ed\u8d1f\u8377 + \u5730\u6696\u56de\u8def + \u65b0\u98ce\u98ce\u91cf\u540c\u6b65\u6d4b\u7b97<\/td><\/tr>\n      <tr><td>\u2461 \u6750\u6599\u8fdb\u573a<\/td><td>\u65e5\u7acb\/\u66fc\u745e\u5fb7\u539f\u5382\u8bbe\u5907 + \u4f1f\u661f\u8f85\u6750\u6838\u9a8c\uff0c\u914d\u7f6e\u5355\u9010\u6761\u52fe\u5bf9<\/td><\/tr>\n      <tr><td>\u2462 \u9690\u853d\u5de5\u7a0b<\/td><td>\u7a7a\u8c03\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u3001\u5730\u6696\u76d8\u7ba1\u4fdd\u538b\u3001\u65b0\u98ce\u98ce\u7ba1\u5bc6\u5c01\uff0c\u5206\u5c42\u4f5c\u4e1a<\/td><\/tr>\n      <tr><td>\u2463 \u4fdd\u538b\u9a8c\u6536<\/td><td>\u7a7a\u8c03R410A\u4fdd\u538b\u3001\u5730\u6696\u6c34\u538b\u8bd5\u9a8c\uff0c\u538b\u964d\u8fbe\u6807\u96f6\u6cc4\u6f0f\u540e\u5f52\u6863<\/td><\/tr>\n      <tr><td>\u2464 \u8bbe\u5907\u5b89\u88c5<\/td><td>\u7a7a\u8c03\u5185\u673a\u540a\u88c5\u3001\u5916\u673a\u843d\u4f4d\u3001\u51b7\u51dd\u7089\u4e0e\u65b0\u98ce\u4e3b\u673a\u5b89\u88c5\u56fa\u5b9a\u51cf\u632f<\/td><\/tr>\n      <tr><td>\u2465 \u8c03\u8bd5\u6559\u5b66<\/td><td>\u4e09\u7cfb\u7edf\u8054\u52a8\u8c03\u8bd5\uff0c\u5206\u533a\u57dfWiFi\u6e29\u63a7\u4f7f\u7528\u6559\u5b66<\/td><\/tr>\n      <tr><td>+1 \u5730\u6696\u56de\u586b<\/td><td>\u76d8\u7ba1\u4e0a\u65b9\u56de\u586b\u627e\u5e73\uff0c\u4fdd\u62a4\u5c42\u65bd\u5de5\u4e0d\u5f71\u54cd\u540e\u7eed\u5de5\u5e8f<\/td><\/tr>\n      <tr><td>+2 \u4ea4\u4ed8\u5efa\u6863<\/td><td>\u9690\u853d\u5de5\u7a0b\u8282\u70b9\u62cd\u7167\u5f52\u6863\uff0c\u4e09\u7cfb\u7edf\u4fdd\u4fee\u51ed\u8bc1\u79fb\u4ea4<\/td><\/tr>\n    <\/table>\n\n    <h3 id=\"s4-gallery\">\u2461 \u4e09\u7cfb\u7edf\u914d\u7f6e\u8be6\u8ff0\uff08\u7b7e\u5355\u65b9\u6848\uff09<\/h3>\n    <div class=\"lm-note lm-ng\">\ud83d\udccb \u672c\u6848\u4f8b\u4e3a<strong>\u7b7e\u5355\u9636\u6bb5<\/strong>\uff082026-07-16 \u5df2\u7b7e\u5355\uff0c\u5f85\u65bd\u5de5\u6392\u671f\uff09\uff0c\u4ee5\u4e0b\u4e3a\u7b7e\u7ea6\u914d\u7f6e\u8be6\u8ff0\uff1b\u65bd\u5de5\u5b9e\u666f\u56fe\u5c06\u4e8e\u5b8c\u5de5\u540e\u8865\u5145\u5f52\u6863\u3002<\/div>\n    <div class=\"lm-card-grid\">\n      <div class=\"lm-card lm-edge-o\"><span class=\"lm-tag\">\u7a7a\u8c03<\/span><h4>\u2744\ufe0f \u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d<\/h4><p>\u53cc\u98ce\u6247200\u578b\u5916\u673a \u00d71\uff1b\u5185\u673a6\u53f0\uff1a\u5ba2\u9910\u538571+56 \/ \u4e3b\u536756 \/ \u8863\u5e3d\u95f422 \/ \u4e66\u623f18 \/ \u5065\u8eab\u623f18\uff1bWiFi\u7ebf\u63a7\u5668 \u00d76\uff0c\u5206\u5ba4\u63a7\u6e29\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-b\"><span class=\"lm-tag lm-blue\">\u5730\u6696<\/span><h4>\ud83d\udd25 \u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696<\/h4><p>\u5c0f\u536124kW\u51b7\u51dd\u7089 \u00d71\uff1b9\u56de\u8def\u4f1f\u661fPE-RT 20\u76d8\u7ba1 + \u767d\u91d1\u677f\u4fdd\u6e29 + 32\u4e3b\u7ba1\uff1b\u8054\u52a8\u63a7\u5236 + \u5206\u533a\u57dfWiFi\u7ebf\u63a7\uff0c\u91c7\u6696\u9762\u79ef132.62\u33a1\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-g\"><span class=\"lm-tag lm-green\">\u65b0\u98ce<\/span><h4>\ud83c\udf00 \u65e5\u7acb\u4e91\u955c252<\/h4><p>\u4e91\u955c\u4e8c\u7cfb\u5217252\u5168\u70ed\u4ea4\u6362\u5668 \u00d71\uff0c\u56de\u6536\u6392\u98ce\u80fd\u91cf\u9884\u51b7\u9884\u70ed\u65b0\u98ce\uff0c\u540c\u65f6\u8fc7\u6ee4PM2.5\uff0c\u63d0\u5347\u5ba4\u5185\u7a7a\u6c14\u54c1\u8d28\u3002<\/p><\/div>\n    <\/div>\n\n    <h3 id=\"s4-warranty\">\u2462 \u670d\u52a1\u4fdd\u969c\u4f53\u7cfb<\/h3>\n    <ul class=\"lm-check\">\n      <li>\u8bbe\u5907\u4fdd\u4fee\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5747\u4eab\u5382\u5bb6\u6574\u673a\u4e0e\u6838\u5fc3\u90e8\u4ef6\u4fdd\u4fee\u653f\u7b56\uff08\u4ee5\u8d2d\u673a\u51ed\u8bc1\u4e3a\u51c6\uff09<\/li>\n      <li>\u5b89\u88c5\u8d28\u4fdd\uff1a\u9f99\u8109\u6696\u901a\u7cbe\u5de5\u5b89\u88c5\u5de5\u827a\u8d28\u4fdd\uff0c\u4e09\u7cfb\u7edf\u9690\u853d\u5de5\u7a0b\u8282\u70b9\u62cd\u7167\u5f52\u6863\u53ef\u8ffd\u6eaf<\/li>\n      <li>\u552e\u540e\u54cd\u5e94\uff1a\u6210\u90fd\u5168\u57df12\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u56de\u8bbf\uff0c\u9ec4\u52c7\u987e\u95ee\u4e13\u7ebf <a href=\"tel:15828489188\">15828489188<\/a><\/li>\n      <li>\u900f\u660e\u6eaf\u6e90\uff1a\u8bbe\u5907\u578b\u53f7\u4e0e\u62a5\u4ef7\u6784\u6210\u5747\u4ee5\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\uff0c\u53ef\u73b0\u573a\u6838\u9a8c<\/li>\n    <\/ul>\n  <\/section>\n\n  <!-- S5 \u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3 -->\n  <section class=\"lm-section\" id=\"s5\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S5<\/div>\n    <h2>\u6848\u4f8b\u9a8c\u8bc1\u4e0e\u8fed\u4ee3<\/h2>\n\n    <h3 id=\"s5-diag\">\u2460 \u914d\u7f6e\u5408\u7406\u6027\u8bca\u65ad<\/h3>\n    <div class=\"lm-note lm-ng\">\u2705 <strong>\u4e09\u7cfb\u7edf\u914d\u7f6e\u5408\u89c4\uff1a<\/strong>\u7a7a\u8c03\u4e00\u62d6\u516d\u5339\u914d\u8212\u4eab200\u578b\u53cc\u98ce\u6247\u5916\u673a\uff0c\u8fde\u63a5\u7387\u7b26\u5408\u6c1f\u7cfb\u7edf50%-130%\u89c4\u8303\u533a\u95f4\uff0c\u5355\u5f00\/\u5168\u5f00\u5747\u4ece\u5bb9\uff1b\u5730\u66969\u56de\u8def\u5bf9\u5e94132.62\u33a1\u91c7\u6696\u9762\u79ef\uff0c\u5355\u56de\u8def\u7ea614-15\u33a1\u8d1f\u8377\u5408\u7406\uff1b\u65b0\u98ce252\u5168\u70ed\u4ea4\u6362\u5668\u9002\u914d120-150\u33a1\u6237\u578b\uff0c\u98ce\u91cf\u5339\u914d\u3002\u4e54\u8001\u5e08\u5bb6\u591a\u623f\u95f4\u6309\u9700\u542f\u505c\uff0c\u5b9e\u9645\u8fd0\u884c\u8d1f\u8377\u4f4e\u4e8e\u540d\u4e49\u603b\u5bb9\u91cf\uff0c\u9009\u578b\u5b89\u5168\u4e0d\u8d85\u914d\u3002<\/div>\n    <div class=\"lm-radar-cap\">\ud83d\udcd0 <b>\u8212\u9002\u578b\u4e09\u5ba4\u9002\u914d\u56db\u7ef4\u5ea6\uff1a<\/b>\u8986\u76d6\uff08\u4e00\u62d6\u516d\u4e94\u533a\u65e0\u6b7b\u89d2\uff09\u00b7 \u91c7\u6696\uff08\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\uff09\u00b7 \u7a7a\u6c14\uff08\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\uff09\u00b7 \u80fd\u6548\uff08\u51b7\u51dd\u7089\u56de\u6536\u4f59\u70ed+\u8054\u52a8\u63a7\u5236\uff09\u2014\u2014\u56db\u4e2a\u7ef4\u5ea6\u5168\u90e8\u547d\u4e2d\u4e54\u8001\u5e08\u8bc9\u6c42\u3002<\/div>\n\n    <h3 id=\"s5-rec\">\u2461 \u9009\u578b\u63a8\u8350<\/h3>\n    <ul class=\"lm-check\">\n      <li><strong>130\u33a1\u5de6\u53f3\u4e09\u5ba4\u3001\u8981\u51b7\u6696+\u7a7a\u6c14\u4e00\u6b65\u5230\u4f4d<\/strong>\uff1a\u63a8\u8350\u672c\u65b9\u6848\uff08\u8212\u4eab200\u4e00\u62d6\u516d + \u66fc\u745e\u5fb7\u51b7\u51dd\u7089 + \u4e91\u955c252\u65b0\u98ce\uff09\uff0c\u4e09\u7cfb\u7edf\u534f\u540c\u3002<\/li>\n      <li><strong>\u9884\u7b97\u5206\u9636\u6bb5\u6295\u5165<\/strong>\uff1a\u53ef\u5148\u4e0a\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\uff0c\u5730\u6696\u4e0e\u65b0\u98ce\u540e\u7eed\u589e\u914d\uff0c\u964d\u4f4e\u4e00\u6b21\u6027\u538b\u529b\u3002<\/li>\n      <li><strong>\u5bf9\u9759\u97f3\u4e0e\u6548\u7387\u8981\u6c42\u66f4\u9ad8<\/strong>\uff1a\u7a7a\u8c03\u53ef\u5347\u7ea7\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff0c\u538b\u7f29\u673a\u4e0e\u7535\u63a7\u518d\u5347\u7ea7\u3002<\/li>\n    <\/ul>\n\n    <h3 id=\"s5-dims\" style=\"margin-top:20px;color:var(--deep-blue)\">\u2462 \u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4\uff08\u672c\u65b9\u6848 vs \u5e02\u573a\u666e\u901a\u65b9\u6848\uff09<\/h3>\n    <table class=\"lm-comparison-table\">\n      <tr><th>\u7ef4\u5ea6<\/th><th>\u5e02\u573a\u666e\u901a\u65b9\u6848<\/th><th>\u672c\u65b9\u6848\uff08\u9f99\u8109\u7cbe\u5de5\uff09<\/th><\/tr>\n      <tr><td>\u51b7\u6696\u8212\u9002<\/td><td>\u2605\u2605\u2605\u2606\u2606<\/td><td>\u2605\u2605\u2605\u2605\u2605\uff08\u4e00\u62d6\u516d\u5206\u533a\u63a7\u6e29\uff09<\/td><\/tr>\n      <tr><td>\u51ac\u5b63\u91c7\u6696<\/td><td>\u2605\u2605\u2606\u2606\u2606\uff08\u4ec5\u7a7a\u8c03\u5236\u70ed\uff09<\/td><td>\u2605\u2605\u2605\u2605\u2605\uff08\u51b7\u51dd\u7089\u5730\u6696\uff09<\/td><\/tr>\n      <tr><td>\u7a7a\u6c14\u54c1\u8d28<\/td><td>\u2605\u2605\u2606\u2606\u2606<\/td><td>\u2605\u2605\u2605\u2605\u2605\uff08\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff09<\/td><\/tr>\n      <tr><td>\u8282\u80fd\u7701\u6c14<\/td><td>\u2605\u2605\u2605\u2606\u2606<\/td><td>\u2605\u2605\u2605\u2605\u2606\uff08\u51b7\u51dd\u7089+\u8054\u52a8\u63a7\u5236\uff09<\/td><\/tr>\n      <tr><td>\u667a\u80fd\u63a7\u5236<\/td><td>\u2605\u2605\u2606\u2606\u2606<\/td><td>\u2605\u2605\u2605\u2605\u2605\uff08WiFi\u5206\u533a\u57df\u8054\u52a8\uff09<\/td><\/tr>\n      <tr><td>\u957f\u671f\u7a33\u5b9a<\/td><td>\u2605\u2605\u2605\u2606\u2606<\/td><td>\u2605\u2605\u2605\u2605\u2606<\/td><\/tr>\n    <\/table>\n    <div class=\"lm-note lm-nb\">\ud83d\udcca <b>\u514d\u8d23\u58f0\u660e\uff1a<\/b>\u672c\u6587\u6240\u5217\u5404\u54c1\u724c\u53c2\u6570\u5747\u5f15\u81ea\u5404\u54c1\u724c\u5b98\u65b9\u516c\u5f00\u8d44\u6599\uff0c\u4ec5\u4f5c\u9009\u578b\u53c2\u8003\uff0c\u4e0d\u6784\u6210\u5bf9\u4efb\u4f55\u54c1\u724c\u7684\u4f18\u52a3\u8bc4\u4ef7\uff1b\u53c2\u6570\u4e0e\u914d\u7f6e\u4ee5\u5404\u54c1\u724c\u5b98\u65b9\u6700\u65b0\u516c\u5e03\u4e3a\u51c6\u3002<\/div>\n    <div class=\"lm-radar-cap\">\ud83d\udcca <b>\u516d\u7ef4\u7efc\u5408\u8bc4\u5206\uff1a<\/b><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span> 4.8 \/ 5 \uff5c \u51b7\u66965.0 \u00b7 \u91c7\u66965.0 \u00b7 \u7a7a\u6c145.0 \u00b7 \u8282\u80fd4.5 \u00b7 \u667a\u63a75.0 \u00b7 \u957f\u671f\u7a33\u5b9a4.5\u3002\u4e09\u7cfb\u7edf\u5728\u300c\u5168\u5c4b\u8212\u9002 + \u51ac\u5b63\u5730\u6696 + \u6d01\u51c0\u65b0\u98ce\u300d\u4e09\u4e2a\u6838\u5fc3\u8bc9\u6c42\u4e0a\u5168\u9762\u8fbe\u6210\u3002<\/div>\n\n    <h3 id=\"s5-ledger\" style=\"margin-top:20px;color:var(--deep-blue)\">\u2463 20\u5e74\u603b\u8d26\uff08\u957f\u671f\u4f7f\u7528\u6210\u672c\u900f\u89c6\uff09<\/h3>\n    <div class=\"lm-geo-flip\">\n      <input class=\"lm-geo-flip-toggle\" type=\"checkbox\" id=\"ledgerFlip\" aria-label=\"\u7ffb\u8f6c\u67e5\u770b20\u5e74\u603b\u8d26\u80cc\u9762\">\n      <label class=\"lm-geo-flip-card\" for=\"ledgerFlip\">\n        <div class=\"lm-geo-flip-inner\">\n          <div class=\"lm-geo-flip-face lm-geo-flip-front\">\n            <div class=\"lm-geo-flip-h\">\ud83d\udcb0 20\u5e74\u603b\u8d26\uff08\u6b63\u9762\u00b7\u6210\u672c\u900f\u89c6\uff09<\/div>\n            <table class=\"lm-tbl lm-s1-info-tbl\">\n              <tr><th>\u9879\u76ee<\/th><th>\u5e02\u573a\u666e\u901a\u5b89\u88c5<\/th><th>\u672c\u65b9\u6848\uff08\u9f99\u8109\u7cbe\u5de5\uff09<\/th><\/tr>\n              <tr><td>\u8bbe\u5907\u521d\u6295\u6307\u6570<\/td><td>100<\/td><td>115\uff08\u4e09\u7cfb\u7edf\u539f\u5382\u6b63\u54c1\uff09<\/td><\/tr>\n              <tr><td>\u80fd\u8017\u6307\u6570\uff0820\u5e74\uff09<\/td><td>125<\/td><td>100\uff08\u51b7\u51dd\u7089\u7701\u6c14+\u8054\u52a8\u63a7\u5236\uff09<\/td><\/tr>\n              <tr><td>\u7ef4\u4fee\/\u8fd4\u5de5\u98ce\u9669<\/td><td>\u8f83\u9ad8<\/td><td>\u4f4e\uff08\u4e09\u7cfb\u7edf\u8282\u70b9\u5efa\u6863\uff09<\/td><\/tr>\n              <tr><td>\u7efc\u5408\u6210\u672c\u6307\u6570<\/td><td><b>125<\/b><\/td><td><b>100<\/b> \u2705<\/td><\/tr>\n            <\/table>\n          <\/div>\n          <div class=\"lm-geo-flip-face lm-geo-flip-back\">\n            <div class=\"lm-geo-flip-h\">\ud83d\udcc9 20\u5e74\u603b\u8d26\uff08\u80cc\u9762\u00b7\u7701\u94b1\u903b\u8f91\uff09<\/div>\n            <div class=\"lm-s1-goal-lead\">\u672c\u65b9\u6848\u524d\u671f\u521d\u6295\u8f83\u9ad8\uff08\u6307\u6570115 vs 100\uff09\uff0c\u4f46\u51ed\u501f<b>\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u4f59\u70ed\u3001\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u6309\u9700\u542f\u505c\u3001\u4e09\u7cfb\u7edf\u8282\u70b9\u5efa\u6863\u53ef\u8ffd\u6eaf<\/b>\u4e09\u9879\u52a8\u4f5c\uff0c\u628a20\u5e74\u91c7\u6696\u80fd\u8017\u4e0e\u8fd4\u5de5\u98ce\u9669\u6709\u6548\u538b\u4f4e\uff1a\u7efc\u5408\u6210\u672c\u6307\u6570\u4ec5100\uff0c\u8f83\u5e02\u573a\u666e\u901a\u5b89\u88c5\uff08125\uff09<b>\u7701\u7ea620%<\/b>\u3002\u8212\u9002\u578b\u4e09\u5ba4\u957f\u671f\u6301\u6709\u66f4\u5212\u7b97\u3002<\/div>\n            <ul class=\"lm-check\">\n              <li>\u80fd\u8017\u7701\uff1a\u51b7\u51dd\u7089\u9ad8\u6548+\u8054\u52a8\u63a7\u5236\uff0c\u71c3\u6c14\u4e0d\u7a7a\u70e7<\/li>\n              <li>\u7ef4\u4fee\u7701\uff1a\u4e09\u7cfb\u7edf\u9690\u853d\u5de5\u7a0b\u8282\u70b9\u5f52\u6863\uff0c\u6545\u969c\u53ef\u6eaf\u6e90<\/li>\n              <li>\u6b8b\u503c\u7a33\uff1a\u539f\u5382\u6b63\u54c1+\u89c4\u8303\u5b89\u88c5\uff0c\u7cfb\u7edf\u5bff\u547d\u66f4\u957f<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n        <div class=\"lm-geo-flip-tip\">\ud83d\udd04 \u70b9\u51fb\u5361\u7247\u7ffb\u8f6c\uff0c\u67e5\u770b20\u5e74\u7701\u94b1\u903b\u8f91<\/div>\n      <\/label>\n    <\/div>\n  <\/section>\n\n  <!-- S6 \u9ad8\u9891\u95ee\u9898 -->\n  <section class=\"lm-section\" id=\"s6\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S6<\/div>\n    <h2>\u9ad8\u9891\u95ee\u9898<\/h2>\n    <div class=\"lm-faq\">\n      <details><summary>132\u33a1\u4e09\u5ba4\u4e24\u5385\u914d\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u516d\u591f\u7528\u5417\uff1f<\/summary><div class=\"lm-faq-a\">\u591f\u7528\u3002\u5ba2\u9910\u5385\u53a8\u623f\u9633\u53f067.32\u33a1\u914d71+56\u4e24\u53f0\u3001\u4e3b\u5367\u8d77\u5c45\u5ba433.5\u33a1\u914d56\u3001\u8863\u5e3d\u95f422\u3001\u4e66\u623f18\u3001\u5065\u8eab\u623f18\uff0c\u51716\u53f0\u5185\u673a\u8986\u76d6\u5168\u5c4b\uff1b\u5916\u673a\u65e5\u7acb\u8212\u4eab\u53cc\u98ce\u6247200\u578b\uff0c\u5355\u5f00\u6216\u5168\u5f00\u90fd\u4ece\u5bb9\u3002<\/div><\/details>\n      <details><summary>\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u4e00\u8d77\u505a\u6709\u4ec0\u4e48\u597d\u5904\uff1f<\/summary><div class=\"lm-faq-a\">\u4e09\u7cfb\u7edf\u534f\u540c\u8986\u76d6\u51b7\u6696\u4e0e\u7a7a\u6c14\u54c1\u8d28\uff1a\u4e2d\u592e\u7a7a\u8c03\u5236\u51b7\u5236\u70ed\u3001\u51b7\u51dd\u7089\u5730\u6696\u51ac\u5b63\u91c7\u6696\u3001\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\u6362\u6c14\u51c0\u5316\u3002\u4e00\u6b21\u52d8\u6d4b\u4e00\u6b21\u65bd\u5de5\uff0c\u7ba1\u8def\u4e0e\u6e29\u63a7\u8054\u52a8\u66f4\u534f\u8c03\uff0c\u957f\u671f\u8fd0\u7ef4\u4e5f\u66f4\u7701\u5fc3\u3002<\/div><\/details>\n      <details><summary>\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u5417\uff1f<\/summary><div class=\"lm-faq-a\">\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u4f59\u70ed\uff0c\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u91c7\u6696\u5b63\u71c3\u6c14\u6d88\u8017\u66f4\u4f4e\uff1b\u914d\u5408\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u4e0e\u5206\u533a\u57dfWiFi\u6e29\u63a7\u6309\u9700\u542f\u505c\uff0c\u957f\u671f\u4f7f\u7528\u66f4\u7701\u3002<\/div><\/details>\n      <details><summary>\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u5168\u70ed\u4ea4\u6362\u6709\u4ec0\u4e48\u7528\uff1f<\/summary><div class=\"lm-faq-a\">\u5168\u70ed\u4ea4\u6362\u5668\u5728\u6392\u51fa\u6d4a\u6c14\u3001\u5f15\u5165\u65b0\u98ce\u65f6\u56de\u6536\u6392\u98ce\u80fd\u91cf\uff0c\u9884\u51b7\u9884\u70ed\u65b0\u98ce\uff0c\u51cf\u5c11\u7a7a\u8c03\u4e0e\u5730\u6696\u8d1f\u8377\uff0c\u540c\u65f6\u8fc7\u6ee4PM2.5\uff0c\u63d0\u5347\u5ba4\u5185\u7a7a\u6c14\u8d28\u91cf\u3002<\/div><\/details>\n      <details><summary>\u4e00\u62d6\u516d\u8fde\u63a5\u7387\u600e\u4e48\u7b97\u3001\u662f\u5426\u5408\u89c4\uff1f<\/summary><div class=\"lm-faq-a\">\u6c1f\u7cfb\u7edf\u5141\u8bb8\u8fde\u63a5\u738750%-130%\u3002\u672c\u65b9\u6848\u5185\u673a\u603b\u5bb9\u91cf\u6309\u5404\u5ba4\u5185\u673a\u6807\u79f0\u5408\u8ba1\u3001\u5916\u673a\u4e3a\u8212\u4eab200\u578b\uff0c\u5355\u5f00\/\u5168\u5f00\u5747\u7559\u6709\u5408\u89c4\u4f59\u91cf\uff0c\u9009\u578b\u5b89\u5168\u4e0d\u8d85\u914d\u3002<\/div><\/details>\n      <details><summary>\u897f\u534e\u82d1\u8fd9\u5957\u65b9\u6848\u9002\u5408\u591a\u5927\u9762\u79ef\u7684\u5bb6\u5ead\uff1f<\/summary><div class=\"lm-faq-a\">\u9002\u5408\u5efa\u9762\u7ea6130\u33a1\u5de6\u53f3\u7684\u4e09\u5ba4\u4e24\u5385\u53ca\u4ee5\u4e0a\u6237\u578b\uff0c\u5c24\u5176\u5ba2\u9910\u5385+\u53a8\u623f+\u9633\u53f0\u8fde\u6210\u5927\u5f00\u95f4\u3001\u591a\u623f\u95f4\u9700\u72ec\u7acb\u63a7\u6e29\u7684\u5bb6\u5ead\uff1b\u5177\u4f53\u4ee5\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u7684\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u4e3a\u51c6\u3002<\/div><\/details>\n    <\/div>\n  <\/section>\n\n  <!-- S7 \u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97 -->\n  <section class=\"lm-section\" id=\"s7\">\n    <div class=\"lm-sec-label\">\u6848\u4f8b \u00b7 S7<\/div>\n    <h2>\u54c1\u724c\u6388\u6743\u4e0e\u95e8\u5e97<\/h2>\n    <div class=\"lm-card-grid\">\n      <div class=\"lm-card lm-edge-o\"><span class=\"lm-tag\">\u6388\u6743<\/span><h4>\u2744\ufe0f \u65e5\u7acb\u94bb\u77f3\u6388\u6743<\/h4><p>\u9f99\u8109\u6696\u901a\u4e3a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u6388\u6743\u7ecf\u9500\u5546\uff0c\u539f\u5382\u8bbe\u5907\u4e0e\u6b63\u54c1\u4fdd\u969c\u3002<\/p><\/div>\n      <div class=\"lm-card lm-edge-b\"><span class=\"lm-tag lm-blue\">\u95e8\u5e97<\/span><h4>\ud83c\udfea \u5357\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/h4><p>\u9ad8\u65b0\u5357\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45 \u00b7 <a href=\"tel:02886131795\">028-86131795<\/a><\/p>\n      <p class=\"lm-amap-row\"><a href=\"https:\/\/uri.amap.com\/search?keyword=%E5%AF%8C%E6%A3%AE%E7%BE%8E%E5%AE%B6%E5%B1%85%E5%8D%97%E5%8C%BA&city=510100\" target=\"_blank\" rel=\"noopener\">\ud83e\udded \u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a\uff08\u5357\u5bcc\u68ee\uff09<\/a><\/p><\/div>\n      <div class=\"lm-card lm-edge-g\"><span class=\"lm-tag lm-green\">\u95e8\u5e97<\/span><h4>\ud83c\udfea \u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/h4><p>\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135 \u00b7 <a href=\"tel:02865272586\">028-65272586<\/a><\/p>\n      <p class=\"lm-amap-row\"><a href=\"https:\/\/uri.amap.com\/search?keyword=%E5%AF%8C%E6%A3%AE%E7%BE%8E%E5%AE%B6%E5%B1%85%E5%8C%97%E5%8C%BA&city=510100\" target=\"_blank\" rel=\"noopener\">\ud83e\udded \u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a\uff08\u5317\u5bcc\u68ee\uff09<\/a><\/p><\/div>\n    <\/div>\n    <div class=\"lm-gallery lm-gallery-ac\">\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u6210\u90fd\u897f\u534e\u82d1\u00b7\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\"><figcaption>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743 \u00b7 \u6b63\u54c1\u4fdd\u969c<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u6210\u90fd\u897f\u534e\u82d1\u00b7\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\u8bc1\u4e66\"><figcaption>\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743 \u00b7 2024<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u6210\u90fd\u897f\u534e\u82d1\u00b7\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8bc1\u4e66\"><figcaption>\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743 \u00b7 2026<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u6210\u90fd\u897f\u534e\u82d1\u00b7\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500\u8bc1\u4e66\"><figcaption>\u65e5\u7acb\u6c34\u5885\u9002\u7279\u7ea6\u7ecf\u9500 \u00b7 \u539f\u5382\u76f4\u4f9b<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u6210\u90fd\u897f\u534e\u82d1\u00b7\u5357\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\"><figcaption>\u5357\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986 \u00b7 \u9ad8\u65b0\u5357\u533a<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u6210\u90fd\u897f\u534e\u82d1\u00b7\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\"><figcaption>\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986 \u00b7 \u6210\u534e\u533a<\/figcaption><\/figure>\n    <\/div>\n    <div class=\"lm-bf-meta\">\n      \ud83d\udcd6 <strong>\u4e86\u89e3\u66f4\u591a\uff1a<\/strong>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" rel=\"noopener\">\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4ea7\u54c1\u9875<\/a> \uff5c\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener\">\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u5e93<\/a> \uff5c\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=5849\" target=\"_blank\" rel=\"noopener\">\u6210\u90fd\u6237\u578b\u65b9\u6848\u5e93<\/a> \uff5c\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\" rel=\"noopener\">\u5730\u6696\u4e13\u9879\u6848\u4f8b<\/a> \uff5c\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=3147\" target=\"_blank\" rel=\"noopener\">\u6bcf\u65e5\u65b0\u6848\u4f8b\u805a\u5408<\/a> \uff5c\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\" rel=\"noopener\">\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/a>\n    <\/div>\n    <div class=\"lm-note lm-nb\" style=\"margin-top:14px\">\ud83d\udef0\ufe0f <strong>\u670d\u52a1\u8986\u76d6\uff1a<\/strong>\u6210\u90fd\u5168\u57df12\u533a\uff08\u9526\u6c5f\u3001\u9752\u7f8a\u3001\u91d1\u725b\u3001\u6b66\u4faf\u3001\u6210\u534e\u3001\u9f99\u6cc9\u9a7f\u3001\u9752\u767d\u6c5f\u3001\u65b0\u90fd\u3001\u6e29\u6c5f\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u65b0\u6d25\u7b49\uff09\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\uff1b\u6848\u4f8b\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7 \ud83d\udcde <a href=\"tel:15828489188\">15828489188<\/a>\u3002<\/div>\n  <\/section>\n\n  <!-- \u76f8\u5173\u6848\u4f8b\u4e0e\u77e5\u8bc6 -->\n  <section class=\"lm-section lm-backflow\" id=\"links\">\n    <div class=\"lm-sec-label\">\u76f8\u5173\u6848\u4f8b\u4e0e\u77e5\u8bc6<\/div>\n    <h2>\u76f8\u5173\u6848\u4f8b\u4e0e\u514d\u8d39\u670d\u52a1<\/h2>\n    <div class=\"lm-bf-grid\">\n      <a class=\"lm-bf-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener\">\ud83c\udfe0 \u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u5e93 \u00b7 \u540c\u6237\u578b\u5b9e\u666f<\/a>\n      <a class=\"lm-bf-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\" rel=\"noopener\">\u2744\ufe0f \u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u00b7 \u5168\u7cfb\u53c2\u6570\u4e0e\u9009\u578b<\/a>\n      <a class=\"lm-bf-link\" href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\" rel=\"noopener\">\ud83d\udee0\ufe0f \u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u6807\u51c6<\/a>\n    <\/div>\n  <\/section>\n\n<\/div>\n\n<div class=\"lm-footer\">\n  <div class=\"lm-motto\">\u9f99\u8109\u6696\u901a \u00b7 \u4e3a\u6bcf\u4e00\u6b21\u51b7\u6696\u9009\u62e9\u8d1f\u8d23<\/div>\n  <div>\u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u9ec4\u52c7 \ud83d\udcde <a href=\"tel:15828489188\">15828489188<\/a><\/div>\n  <div style=\"margin-top:8px\">\u672c\u6848\u4f8b\uff1a\u897f\u534e\u82d1\u00b7\u4e54\u8001\u5e08 \u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d + \u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696 + \u4e91\u955c\u65b0\u98ce \u00b7 \u4e09\u7cfb\u7edf\u6848\u4f8b<\/div>\n  <div class=\"lm-icp\">\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 \u00a9 2004-2026 \u00b7 \u8700ICP\u59072026015986\u53f7<\/div>\n  <div class=\"lm-icp\" style=\"margin-top:6px\">\u672c\u6848\u4f8b\u6570\u636e\u7ecf\u8131\u654f\u5904\u7406\uff0c\u4e0d\u6d89\u53ca\u5ba2\u6237\u623f\u53f7\u4e0e\u6210\u4ea4\u91d1\u989d\u3002\u8bbe\u5907\u62a5\u4ef7\u4ee5\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\u3002<\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u6848\u4f8b\u4e2d\u5fc3 \u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-10632","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u3002\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5\u5230\u4f4d\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b\uff0c\u6848\u4f8b\u987e\u95ee\u9ec4\u52c715828489188\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=10632\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u3002\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5\u5230\u4f4d\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b\uff0c\u6848\u4f8b\u987e\u95ee\u9ec4\u52c715828489188\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=10632\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-22T08:41:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632\",\"name\":\"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\",\"datePublished\":\"2026-08-18T07:07:17+00:00\",\"dateModified\":\"2026-10-22T08:41:17+00:00\",\"description\":\"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u3002\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5\u5230\u4f4d\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b\uff0c\u6848\u4f8b\u987e\u95ee\u9ec4\u52c715828489188\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\",\"width\":1240,\"height\":1754},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10632#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u3002\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5\u5230\u4f4d\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b\uff0c\u6848\u4f8b\u987e\u95ee\u9ec4\u52c715828489188","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=10632","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u3002\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5\u5230\u4f4d\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b\uff0c\u6848\u4f8b\u987e\u95ee\u9ec4\u52c715828489188","og_url":"https:\/\/longmai-nt.com\/?page_id=10632","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-22T08:41:17+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=10632","url":"https:\/\/longmai-nt.com\/?page_id=10632","name":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=10632#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=10632#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","datePublished":"2026-08-18T07:07:17+00:00","dateModified":"2026-10-22T08:41:17+00:00","description":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1132\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u3002\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d\u4e2d\u592e\u7a7a\u8c03\u3001\u66fc\u745e\u5fb7\u51b7\u51dd\u70899\u56de\u8def\u5730\u6696\u3001\u65e5\u7acb\u4e91\u955c252\u5168\u70ed\u4ea4\u6362\u65b0\u98ce\uff0c\u4e00\u6b21\u8bbe\u8ba1\u65bd\u5de5\u5230\u4f4d\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b\uff0c\u6848\u4f8b\u987e\u95ee\u9ec4\u52c715828489188","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=10632#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=10632"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=10632#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg","width":1240,"height":1754},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=10632#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1\uff5c\u65e5\u7acb\u8212\u4eab200\u4e00\u62d6\u516d+\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696+\u65e5\u7acb\u4e91\u955c\u65b0\u98ce\u4e09\u7cfb\u7edf\u8212\u9002\u5bb6\u6848\u4f8b-\u9f99\u8109\u6696\u901a"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10632","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10632"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10632\/revisions"}],"predecessor-version":[{"id":16190,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10632\/revisions\/16190"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10632"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}