{"id":10680,"date":"2026-08-18T18:10:49","date_gmt":"2026-08-18T10:10:49","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=10680"},"modified":"2026-10-23T13:47:45","modified_gmt":"2026-10-23T05:47:45","slug":"%e6%88%90%e9%83%bd%e5%8f%8c%e6%b5%81%e5%8c%ba%e4%b8%a4%e6%b1%9f%e6%98%a0%e6%9c%88%e6%97%a5%e7%ab%8b%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e4%b8%80%e6%8b%96%e5%9b%9b%e6%a1%88%e4%be%8b","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=10680","title":{"rendered":"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b"},"content":{"rendered":"\n\n<style>\n:root{\n  --deep-orange:#B5572B;\n  --orange:#E07B3E;\n  --orange-light:#EC9A66;\n  --orange-soft:#FBEBDC;\n  --white:#fff;\n  --bg:#fdf7f0;\n  --text-dark:#2e2a22;\n  --text-gray:#6b6256;\n  --text-light:#a89c86;\n  --toc-height:52px;\n  --card-radius:12px;\n  --shadow:0 4px 18px rgba(224,123,62,.12);\n}\n*{margin:0;padding:0;box-sizing:border-box}\nbody{font-family:\"Microsoft YaHei\",\"PingFang SC\",-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;color:var(--text-dark);background:var(--bg);line-height:1.75;font-size:16px}\na{color:var(--deep-orange);text-decoration:none}\n\n\/* ===== Hero ===== *\/\n.hero{position:relative;aspect-ratio:3\/1;max-height:420px;min-height:260px;display:flex;align-items:center;justify-content:center;background-color:#B5572B;background-image:linear-gradient(135deg,rgba(120,60,25,0.32) 0%,rgba(181,87,43,0.20) 50%,rgba(224,123,62,0.34) 100%),url(https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-12.jpeg);background-size:cover,cover;background-position:center,center;background-repeat:no-repeat,no-repeat;overflow:hidden;max-width:1352px;margin:0 auto 16px;border-radius:0;box-shadow:inset 0 -40px 80px rgba(0,0,0,0.22),inset 0 30px 60px rgba(255,255,255,0.10),0 10px 36px rgba(181,87,43,0.40)}\n.hero::before{content:'';position:absolute;inset:0;z-index:1;background:linear-gradient(135deg,rgba(120,60,25,0.30) 0%,rgba(181,87,43,0.16) 50%,rgba(224,123,62,0.20) 100%),radial-gradient(ellipse at 50% 35%,transparent 35%,rgba(0,0,0,0.18) 100%)}\n.hero-inner{position:relative;z-index:2;display:flex;flex-direction:column;align-items:center;justify-content:center;text-align:center;padding:20px;width:100%;max-width:760px}\n.hero-tagline{font-size:0.85rem;color:rgba(255,255,255,0.90);letter-spacing:2px;margin-bottom:10px}\n.hero-title{font-size:clamp(1.4rem,4vw,2.3rem);font-weight:700;color:#fff;margin-bottom:8px;text-shadow:0 2px 12px rgba(0,0,0,0.4);line-height:1.3}\n.hero-subtitle{font-size:clamp(0.9rem,2vw,1.15rem);color:rgba(255,255,255,0.94);margin-bottom:20px}\n.hero-date{font-size:0.75rem;color:rgba(255,255,255,0.66);margin-top:8px}\n.hero-info-card{display:flex;gap:18px;flex-wrap:wrap;justify-content:center;backdrop-filter:blur(12px);-webkit-backdrop-filter:blur(12px);background:rgba(255,255,255,0.16);border-radius:12px;padding:16px 24px;border:1px solid rgba(255,255,255,0.25)}\n.hero-info-item{text-align:center;min-width:90px}\n.hero-info-item .label{font-size:0.7rem;color:rgba(255,255,255,0.82);letter-spacing:1px;margin-bottom:3px}\n.hero-info-item .value{font-size:1.02rem;font-weight:700;color:#fff}\n\n\/* ===== \u7ffb\u8f6c\u5361 ===== *\/\n.flip-card{position:relative;max-width:1100px;margin:20px auto 0;perspective:1600px;cursor:pointer}\n.flip-inner{position:relative;display:grid;transition:transform .7s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d}\n.flip-card.flipped .flip-inner{transform:rotateY(180deg)}\n.flip-front,.flip-back{grid-area:1\/1;backface-visibility:hidden;-webkit-backface-visibility:hidden;background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);border:1px solid var(--orange-soft);border-top:3px solid var(--orange);padding:24px 30px}\n.flip-back{transform:rotateY(180deg);border-top-color:var(--deep-orange)}\n.flip-hint{text-align:center;font-size:12px;color:var(--text-light);margin-top:10px;letter-spacing:.5px}\n\n.focus-text{font-size:14px;line-height:1.9;color:var(--text-dark);text-align:justify;margin:0}\n.info-block{margin-bottom:18px;padding-bottom:14px;border-bottom:1px dashed #f0d9c4}\n.info-block:last-child{border-bottom:none;margin-bottom:0;padding-bottom:0}\n.info-block-h{font-size:0.92rem;font-weight:700;color:var(--orange);margin-bottom:10px;letter-spacing:.5px}\n.info-row{display:flex;gap:20px;flex-wrap:wrap;margin-bottom:10px}\n.info-cell{flex:1;min-width:130px}\n.info-cell .lbl{font-size:0.78rem;color:var(--text-gray);margin-bottom:2px}\n.info-cell .val{font-size:0.95rem;font-weight:600;color:var(--text-dark)}\n.quote{font-size:0.9rem;line-height:1.7;color:var(--text-dark);background:#fdf3e9;border-left:3px solid var(--orange);padding:12px 16px;border-radius:0 6px 6px 0;margin:0 0 16px}\n\n\/* ===== TOC ===== *\/\n.toc-wrapper{position:sticky;top:0;z-index:100;background:var(--white);border-bottom:1px solid #f0d9c4;height:var(--toc-height);display:flex;align-items:center;justify-content:center;max-width:1100px;margin:0 auto;padding:0 24px;-webkit-overflow-scrolling:touch}\n.toc{display:flex;gap:6px;min-width:max-content}\n.toc-btn{padding:6px 16px;border-radius:20px;font-size:13px;font-weight:600;cursor:pointer;border:1px solid #ddd;background:var(--white);color:var(--text-gray);transition:all .2s}\n.toc-btn.active,.toc-btn:hover{background:var(--deep-orange);color:var(--white);border-color:var(--deep-orange)}\n\n\/* ===== Sections ===== *\/\n.step-section{max-width:1100px;margin:24px auto;padding:0 24px}\n.step-head{display:flex;align-items:center;gap:10px;margin-bottom:16px}\n.step-num{display:inline-flex;align-items:center;justify-content:center;width:36px;height:36px;border-radius:50%;background:var(--deep-orange);color:var(--orange);font-size:16px;font-weight:700}\n.step-label{font-size:18px;font-weight:700;color:var(--deep-orange)}\n\n\/* ===== Section Tabs ===== *\/\n.section-tabs{display:flex;gap:4px;margin-bottom:16px;border-bottom:2px solid #f0d9c4;padding-bottom:0;flex-wrap:wrap}\n.section-tab{padding:8px 16px;font-size:13px;font-weight:600;cursor:pointer;border-bottom:2px solid transparent;color:var(--text-gray);transition:all .2s;margin-bottom:-2px}\n.section-tab.active{color:var(--deep-orange);border-bottom-color:var(--deep-orange)}\n\n\/* ===== Cards ===== *\/\n.content-card{background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);padding:24px 28px;margin-bottom:16px;border:1px solid #fae7d6}\n.card-title{font-size:16px;font-weight:700;color:var(--deep-orange);margin-bottom:10px}\n.card-desc{font-size:14px;color:var(--text-gray);line-height:1.7}\n.card-desc strong{color:var(--deep-orange)}\n\n\/* ===== Conclusion Bar ===== *\/\n.conclusion-bar{background:linear-gradient(90deg,#fdf1e4,#fbe4d2);border-left:4px solid var(--orange);border-radius:8px;padding:12px 16px;font-size:13.5px;color:#B5572B;font-weight:600;margin-bottom:16px;line-height:1.6}\n\n\/* ===== Info Table ===== *\/\n.info-table{width:100%;border-collapse:collapse;margin:12px 0}\n.info-table th{background:var(--deep-orange);color:var(--white);font-size:14px;font-weight:600;padding:10px 14px;text-align:left}\n.info-table td{font-size:14px;padding:10px 14px;border-bottom:1px solid #fae7d6}\n.info-table tr:nth-child(even) td{background:#fdf6ef}\n\n\/* ===== Compare Table ===== *\/\n.compare-table{width:100%;border-collapse:collapse;margin:12px 0}\n.compare-table th{font-size:13px;font-weight:600;padding:8px 12px;text-align:center}\n.compare-table td{font-size:13px;padding:8px 12px;text-align:center;border-bottom:1px solid #fae7d6}\n.compare-table .col-recommend{background:#fdeede;color:#B5572B;font-weight:600}\n.compare-table .col-normal{background:#f3efe8;color:#8a7d68;font-weight:600}\n.compare-table .col-header-b{background:var(--orange);color:var(--white)}\n.compare-table .col-header-a{background:var(--deep-orange);color:var(--white)}\n\n\/* ===== Tags ===== *\/\n.tag{display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;margin:2px}\n.tag.gold{background:rgba(224,123,62,.16);color:var(--deep-orange)}\n.tag.blue{background:rgba(181,87,43,.10);color:var(--deep-orange)}\n\n\/* ===== Promise Grid ===== *\/\n.promise-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:12px 0}\n.promise-card{background:var(--white);border-radius:8px;padding:16px;box-shadow:var(--shadow);text-align:center;border:1px solid #fae7d6}\n.promise-card .icon{font-size:24px;margin-bottom:6px}\n.promise-card .title{font-size:14px;font-weight:700;color:var(--deep-orange)}\n.promise-card .desc{font-size:12px;color:var(--text-gray)}\n\n\/* ===== FAQ ===== *\/\n.faq-item{background:var(--white);border-radius:8px;padding:16px;margin-bottom:10px;box-shadow:var(--shadow);border:1px solid #fae7d6}\n.faq-q{font-size:15px;font-weight:700;color:var(--deep-orange);margin-bottom:6px}\n.faq-a{font-size:14px;color:var(--text-gray);line-height:1.7}\n\n\/* ===== Cert Grid ===== *\/\n.cert-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(280px,1fr));gap:12px;margin:12px 0}\n.cert-item{text-align:center}\n.cert-item img{max-width:100%;border-radius:8px;box-shadow:var(--shadow);margin-bottom:6px}\n.cert-item .label{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Photo Grid ===== *\/\n.photo-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:14px 0}\n.photo-grid img{width:100%;height:auto;border-radius:6px;cursor:pointer;transition:transform .2s;display:block}\n.photo-grid img:hover{transform:scale(1.03)}\n.photo-item{margin:0}\n.photo-item figcaption{font-size:12px;color:var(--text-gray);text-align:center;margin-top:6px;line-height:1.45;padding:0 2px}\n.photo-phase{margin-bottom:16px}\n.photo-phase .phase-label{font-size:13px;font-weight:700;color:var(--deep-orange);margin-bottom:6px}\n.photo-count{font-size:11px;color:var(--text-light)}\n\n\/* ===== Timeline ===== *\/\n.timeline{margin:16px 0}\n.timeline-step{display:flex;gap:12px;margin-bottom:12px;align-items:flex-start}\n.timeline-dot{width:12px;height:12px;border-radius:50%;background:var(--orange);margin-top:4px;flex-shrink:0}\n.timeline-label{font-size:13px;font-weight:700;color:var(--deep-orange);min-width:100px}\n.timeline-detail{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Advantage Grid ===== *\/\n.advantage-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(220px,1fr));gap:12px;margin:12px 0}\n.advantage-card{background:var(--white);border-radius:8px;padding:16px;box-shadow:var(--shadow);text-align:center;border:1px solid #fae7d6}\n.advantage-card .icon{font-size:22px;color:var(--orange);margin-bottom:4px}\n.advantage-card .title{font-size:14px;font-weight:700;color:var(--deep-orange)}\n.advantage-card .desc{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Store Card ===== *\/\n.store-card{background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);overflow:hidden;margin-bottom:12px;border:1px solid #fae7d6}\n.store-card img{width:100%;height:180px;object-fit:cover}\n.store-card .store-info{padding:14px}\n.store-card .store-name{font-size:14px;font-weight:700;color:var(--deep-orange)}\n.store-card .store-addr{font-size:12px;color:var(--text-gray)}\n\n.highlight{color:var(--deep-orange);font-weight:700}\n\n\/* ===== Disclaimer ===== *\/\n.disclaimer{background:#fdf6ef;border-radius:8px;padding:16px;margin:12px 0;font-size:12px;color:var(--text-light);border:1px dashed #e8c9a8}\n\n\/* ===== Keywords Hidden ===== *\/\n.keywords-block{display:none;font-size:0;color:transparent}\n\n\/* ===== \u5916\u94fe\u80f6\u56ca ===== *\/\n.ext-link{display:inline-block;padding:8px 16px;margin:6px 8px 6px 0;border:1px solid var(--orange);border-radius:22px;font-size:13px;font-weight:600;color:var(--deep-orange);background:rgba(224,123,62,.08);transition:all .2s}\n.ext-link:hover{background:var(--orange);color:#fff}\n\n\/* ===== Responsive ===== *\/\n@media(max-width:768px){\n  .hero-title{font-size:24px}\n  .hero-info-card{flex-direction:column;gap:6px}\n  .step-section{padding:0 16px}\n  .photo-grid{grid-template-columns:repeat(2,1fr)}\n  .info-row{flex-direction:column}\n  .compare-table{font-size:11px}\n  .promise-grid{grid-template-columns:repeat(2,1fr)}\n  .advantage-grid{grid-template-columns:repeat(2,1fr)}\n  .cert-grid{grid-template-columns:1fr}\n  .timeline-step{flex-direction:column}\n  .content-card{padding:18px 20px}\n  .section-tabs{flex-wrap:wrap}\n}\n@media(max-width:480px){\n  .hero-title{font-size:20px}\n  .photo-grid{grid-template-columns:1fr}\n  .toc-btn{padding:4px 10px;font-size:12px}\n}\n<\/style>\n\n<!-- ===== \u82f1\u96c4\u680f ===== -->\n<section class=\"hero\" id=\"hero\">\n  <div class=\"hero-inner\">\n    <div class=\"hero-tagline\">\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6 \u00b7 \u771f\u5b9e\u6848\u4f8b\u5b9e\u6d4b<\/div>\n    <h1 class=\"hero-title\">\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708<br>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b<\/h1>\n    <p class=\"hero-subtitle\">\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u65b0\u88c5 \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db \u00b7 \u9759\u97f3+\u81ea\u6e05\u6d01+\u9632\u6f0f\u6c34 \u00b7 \u65e5\u7cfb\u8001\u724c\u54c1\u8d28\u653e\u5fc3 \u00b7 \u5357\u5bcc\u68ee\u95e8\u5e97\u5bf9\u63a5\u843d\u5730<\/p>\n    <div class=\"hero-info-card\">\n      <div class=\"hero-info-item\"><div class=\"label\">\u7a7a\u8c03<\/div><div class=\"value\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u7cfb\u7edf\u5f62\u5f0f<\/div><div class=\"value\">\u4e00\u62d6\u56db\u591a\u8054\u673a<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u5ba4\u5916\u4e3b\u673a<\/div><div class=\"value\">RAS-125HRNAQ<br>12.5kW\u53cc\u8f6c\u5b50<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u5ba4\u5185\u673a<\/div><div class=\"value\">4\u53f0\u8212\u4eab\u5185\u673a<br>RPIZ-71\/36\/25\/28<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u6838\u5fc3\u8bc9\u6c42<\/div><div class=\"value\">\u9759\u97f3\u00b7\u81ea\u6e05\u6d01\u00b7\u9632\u6f0f<\/div><\/div>\n    <\/div>\n    <p class=\"hero-date\">\u66f4\u65b0\uff1a2026\u5e7408\u6708<\/p>\n  <\/div>\n<\/section>\n\n<!-- ===== hero \u4e0b\u65b9\u8fde\u8d2f\u53d9\u4e8b\uff08\u7c73\u59d0\u4e3a\u5973\u513f\u5a5a\u623f\u9009\u7a7a\u8c03\uff09 ===== -->\n<section style=\"max-width:1100px;margin:0 auto 8px;padding:18px 24px;background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow)\">\n  <div class=\"card-title\" style=\"margin-bottom:10px\">\ud83d\udcd6 \u4ece\u5357\u5bcc\u68ee\u901b\u5e97\u5230\u4e00\u62d6\u56db\u843d\u5b9a<\/div>\n  <p style=\"font-size:15px;line-height:1.9;color:var(--text-gray);margin:0;text-indent:2em\">\u7c73\u59d0\uff08\u7c73\u8001\u5e08\uff09\u7ed9\u5973\u513f\u51c6\u5907\u5a5a\u623f\uff0c\u88c5\u4fee\u5230\u7a7a\u8c03\u8fd9\u73af\u683c\u5916\u4e0a\u5fc3\u2014\u2014\u5979\u4e0d\u53ea\u8981\"\u80fd\u5236\u51b7\"\uff0c\u66f4\u8981\u4f4f\u5f97\u5b89\u5fc3\u3001\u4f4f\u5f97\u8212\u670d\u3002\u8dd1\u4e86\u51e0\u5bb6\u6696\u901a\u5e97\uff0c\u6700\u540e\u5728\u5357\u5bcc\u68ee\u9f99\u8109\u6696\u901a\u5c55\u4f4d\u5b9a\u4e86\u4e0b\u6765\uff0c\u539f\u56e0\u5f88\u5b9e\u5728\uff1a\u7b2c\u4e00\uff0c\u5979\u770b\u4e2d\u65e5\u7acb\u5185\u673a\u7684<strong>\u9759\u97f3<\/strong>\u8868\u73b0\uff0c\u5a5a\u623f\u5367\u5ba4\u591c\u91cc\u5b89\u7761\u4e0d\u88ab\u55e1\u55e1\u58f0\u6253\u6270\uff1b\u7b2c\u4e8c\uff0c\u770b\u91cd\u65e5\u7acb<strong>\u81ea\u6e05\u6d01<\/strong>\u529f\u80fd\uff0c\u957f\u671f\u7528\u4e5f\u4e0d\u6613\u79ef\u7070\u53d1\u9709\u3001\u7a7a\u6c14\u66f4\u5e72\u51c0\uff0c\u5bf9\u5c06\u8981\u5165\u4f4f\u7684\u5c0f\u4e24\u53e3\u662f\u5b9e\u6253\u5b9e\u7684\u5065\u5eb7\u8003\u91cf\uff1b\u7b2c\u4e09\uff0c\u5979\u7279\u522b\u95ee\u4e86<strong>\u9632\u6f0f\u6c34\u88c5\u7f6e<\/strong>\uff0c\u6015\u7a7a\u8c03\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u521a\u88c5\u597d\u7684\u540a\u9876\u548c\u5730\u677f\uff1b\u7b2c\u56db\uff0c\u5979\u8ba4\u65e5\u7cfb\u8001\u54c1\u724c\u7684\u5e95\u5b50\uff0c\"\u8d28\u91cf\u662f\u6ca1\u6709\u8bdd\u8bf4\u7684\"\u3002\u5728\u9500\u552e\u628a\u4e00\u62d6\u56db\u5206\u533a\u8986\u76d6\u3001\u9759\u97f3\u81ea\u6e05\u6d01\u539f\u7406\u3001\u9632\u6f0f\u914d\u7f6e\u8bb2\u6e05\u695a\u540e\uff0c\u7c73\u59d0\u723d\u5feb\u5b9a\u4e86\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff0c\u4ece\u65b9\u6848\u5230\u5b89\u88c5\u6bcf\u4e00\u6b65\u90fd\u770b\u5f97\u660e\u660e\u767d\u767d\u3002\uff08\u6ce8\uff1a\u672c\u6bb5\u636e\u9700\u6c42\u7eaa\u8981\u91cd\u6784\uff0c\u5f85\u8865\u7c73\u8001\u5e08\u771f\u5b9e\u5bf9\u8bdd\u539f\u6587\uff09<\/p>\n<\/section>\n\n<!-- ===== \u7ffb\u8f6c\u5361\uff1a\u6848\u4f8b\u6863\u6848 \/ \u7126\u70b9\u5173\u952e\u8bcd\u00b7\u6848\u4f8b\u6458\u8981 ===== -->\n<section class=\"flip-card\" id=\"case-flip\" onclick=\"flipCard(this)\" title=\"\u70b9\u51fb\u7ffb\u9762\u67e5\u770b\u7126\u70b9\u5173\u952e\u8bcd\u00b7\u6848\u4f8b\u6458\u8981\">\n  <div class=\"flip-inner\">\n    <div class=\"flip-front\">\n      <h3 class=\"card-title\">\ud83d\udccb \u6848\u4f8b\u6863\u6848<\/h3>\n      <div class=\"quote\">\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\uff08\u4e8c\u6c5f\u5bfaTOD\u00b7\u957f\u987a\u5927\u9053\u4e00\u6bb555\u53f7\uff09 \u00b7 \u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u65b0\u88c5 \u00b7 \u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff08\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\uff09 \u00b7 \u5ba4\u5916\u4e3b\u673a RAS-125HRNAQ \u00d7 1\u53f0\uff08\u5236\u51b712.5kW\u00b7\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u00b7APF\u4e00\u7ea75.9\u00b7770\u00d7980\u00d7360mm\uff09 \u00b7 \u5ba4\u5185\u673a 4\u53f0\u8212\u4eab\u5185\u673a\uff08RPIZ-71+36+25+28 FSNAQD\/P \u00b7 \u989d\u51b77100+3600+2500+2800=16000W \u00b7 \u8fde\u63a5\u73871.28\uff09 \u00b7 \u6838\u5fc3\u8bc9\u6c42\uff1a\u9759\u97f3+\u81ea\u6e05\u6d01+\u9632\u6f0f\u6c34+\u65e5\u7cfb\u54c1\u8d28 \u00b7 \u9f99\u8109\u6696\u901a22\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u843d\u5730<\/div>\n      <div class=\"info-block\">\n        <div class=\"info-block-h\">\ud83c\udfe0 \u5efa\u7b51\u4fe1\u606f<\/div>\n        <div class=\"info-row\">\n          <div class=\"info-cell\"><div class=\"lbl\">\u697c\u76d8<\/div><div class=\"val\">\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u6237\u578b<\/div><div class=\"val\">\u5e73\u5c42\u00b73\u623f2\u5385\u00b7\u5973\u513f\u5a5a\u623f<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u5236\u51b7\u8ba1\u7b97\u9762\u79ef<\/div><div class=\"val\">\u6309\u51b7\u91cf\u6307\u6807\u5408\u8ba1\u7ea6 78.8\u33a1<br><span style=\"font-size:11px;color:var(--text-light);font-weight:400\">\uff08\u5efa\u7b51\u5957\u5185\u4ee5\u8865\u7b7e\u5408\u540c\/\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\uff09<\/span><\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u57ce\u5e02<\/div><div class=\"val\">\u6210\u90fd \u00b7 \u53cc\u6d41\u533a<\/div><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"info-block\">\n        <div class=\"info-block-h\">\u2744\ufe0f \u7cfb\u7edf\u914d\u7f6e<\/div>\n        <div class=\"info-row\">\n          <div class=\"info-cell\"><div class=\"lbl\">\u7a7a\u8c03<\/div><div class=\"val\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u6c1f\u7cfb\u7edf\u591a\u8054\u673a<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u5ba4\u5916\u4e3b\u673a<\/div><div class=\"val\">RAS-125HRNAQ \u00d7 1\u53f0<br>12.5kW \u00b7 \u53cc\u8f6c\u5b50<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u5ba4\u5185\u673a<\/div><div class=\"val\">\u8212\u4eab\u5185\u673a 4\u53f0<br>RPIZ-71+36+25+28 FSNAQD\/P<br>\u8fde\u63a5\u73871.28 \/ \u603b\u51b716.0kW<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u7cfb\u7edf\u5f62\u5f0f<\/div><div class=\"val\">\u4e00\u62d6\u56db\u591a\u8054\u673a<\/div><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"info-block\">\n        <div class=\"info-block-h\">\ud83d\udee0\ufe0f \u670d\u52a1\u4fe1\u606f<\/div>\n        <div class=\"info-row\">\n          <div class=\"info-cell\"><div class=\"lbl\">\u65bd\u5de5\u65b9<\/div><div class=\"val\">\u9f99\u8109\u6696\u901a\u300122\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u987e\u95ee<\/div><div class=\"val\">\u4f59\u7231\u82f1 13908183204<\/div><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <div class=\"flip-back\">\n      <h3 class=\"card-title\">\ud83d\udccc \u7126\u70b9\u5173\u952e\u8bcd \u00b7 \u6848\u4f8b\u6458\u8981<\/h3>\n      <p class=\"focus-text\">\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\uff08\u4e8c\u6c5f\u5bfaTOD\uff09\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u65b0\u88c5\uff0c\u7531\u9f99\u8109\u6696\u901a\uff0822\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff09\u843d\u5730\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u65b9\u6848\u2014\u2014\u65e5\u7acb\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\uff0c\u5ba4\u5916\u4e3b\u673a\u62d64\u53f0\u5ba4\u5185\u673a\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u4e1a\u4e3b\u4e3a\u5973\u513f\u5a5a\u623f\u88c5\u4fee\uff0c\u6838\u5fc3\u8bc9\u6c42\u662f\u65e5\u7acb\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u6c34\u88c5\u7f6e\u4e0e\u65e5\u7cfb\u8001\u724c\u54c1\u8d28\u653e\u5fc3\u3002\u672c\u6848\u4ee5\"\u4e00\u62d6\u56db+\u5145\u6c2e\u710a\u63a5\u94dc\u7ba1\u5de5\u827a+\u51b7\u51dd\u6c34\u9632\u6f0f\u914d\u7f6e+\u76d1\u7406\u5de1\u68c0\u540c\u6b65\"\u843d\u5730\uff0c\u63d0\u4f9b\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u53ca\u5468\u8fb9\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u3001\u5b9a\u5236\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\uff0c22\u5e74\u672c\u571f\u7cbe\u5de5\u65bd\u5de5\u3002<\/p>\n    <\/div>\n  <\/div>\n  <div class=\"flip-hint\">\ud83d\udc46 \u70b9\u51fb\u5361\u7247\u7ffb\u9762 \u00b7 \u67e5\u770b\u7126\u70b9\u5173\u952e\u8bcd \u00b7 \u6848\u4f8b\u6458\u8981<\/div>\n<\/section>\n\n<!-- ===== \u9876\u90e8\u5bfc\u822a\u6807\u7b7e ===== -->\n<nav class=\"toc-wrapper\" id=\"toc-nav\">\n  <div class=\"toc\">\n    <button class=\"toc-btn active\" onclick=\"scrollToSection('s1')\">S1 \u5ba2\u6237\u76ee\u6807<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s2')\">S2 \u9700\u6c42\u8bca\u65ad<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s3')\">S3 \u65b9\u6848\u6210\u672c<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s4')\">S4 \u65bd\u5de5\u4fdd\u969c<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s5')\">S5 \u9a8c\u8bc1\u8fed\u4ee3<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s6')\">S6 \u95e8\u5e97\u6388\u6743<\/button>\n  <\/div>\n<\/nav>\n\n<!-- ============================================================ -->\n<!-- S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807                                              -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s1\">\n  <div class=\"step-head\">\n    <span class=\"step-num\">S1<\/span>\n    <span class=\"step-label\">\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/span>\n  <\/div>\n\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s1-tab1')\">\u5ba2\u6237\u4fe1\u606f\u5361<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s1-tab2')\">\u8212\u9002\u76ee\u6807<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s1-tab3')\">\u7cfb\u7edf\u603b\u89c8<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s1-tab4')\">\u670d\u52a1\u7406\u5ff5<\/div>\n  <\/div>\n\n  <div id=\"s1-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83d\udccc \u6838\u5fc3\u8981\u70b9\uff1a\u7c73\u8001\u5e08\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u5973\u513f\u5a5a\u623f\u65b0\u88c5\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u5bf9\u63a5\u843d\u5b9a\uff0c\u770b\u91cd\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u6c34\u4e0e\u65e5\u7cfb\u54c1\u8d28\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udccb \u9879\u76ee\u6982\u51b5<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr>\n        <tr><td>\u5ba2\u6237<\/td><td>\u7c73\u8001\u5e08\uff08\u7c73\u59d0\uff09 \u00b7 \u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708 \u00b7 \u5973\u513f\u5a5a\u623f\u65b0\u88c5<\/td><\/tr>\n        <tr><td>\u697c\u76d8<\/td><td>\u4e24\u6c5f\u6620\u6708\uff08\u4e8c\u6c5f\u5bfaTOD\uff0c\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u957f\u987a\u5927\u9053\u4e00\u6bb555\u53f7\uff0c\u5251\u5357\u5927\u9053\u5357\u6bb5\u4e0e\u957f\u987a\u5927\u9053\u4e00\u6bb5\u4ea4\u6c47\u5904\uff09<\/td><\/tr>\n        <tr><td>\u623f\u5c4b<\/td><td>\u5e73\u5c42\u00b73\u623f2\u5385\u00b7\u5973\u513f\u5a5a\u623f\u65b0\u88c5\uff08\u5236\u51b7\u8ba1\u7b97\u9762\u79ef\u7ea678.8\u33a1\uff0c\u5efa\u7b51\u5957\u5185\u4ee5\u8865\u7b7e\u5408\u540c\/\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\uff09<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf<\/td><td>\u65e5\u7acb\u8212\u4eab\u7cfb\u5217 \u6c1f\u7cfb\u7edf\u4e00\u62d6\u56db \u00b7 \u5916\u673a RAS-125HRNAQ\uff08\u5236\u51b712.5kW\u00b7\u53cc\u8f6c\u5b50\u00b7APF\u4e00\u7ea75.9\uff09\u62d6 RPIZ-71\/36\/25\/28 FSNAQD\/P 4\u53f0\u5185\u673a\uff08\u603b\u51b716.0kW\u00b7\u8fde\u63a5\u73871.28\uff09<\/td><\/tr>\n        <tr><td>\u65bd\u5de5\u65b9<\/td><td>\u9f99\u8109\u6696\u901a\uff0822\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff09<\/td><\/tr>\n        <tr><td>\u9500\u552e\u987e\u95ee<\/td><td>\u4f59\u7231\u82f1 13908183204\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/td><\/tr>\n        <tr><td>\u95e8\u5e97<\/td><td>\u5357\u5bcc\u68ee3\u697cA348\uff08\u5bf9\u63a5\u95e8\u5e97\uff09 \uff5c \u5317\u5bcc\u68ee5\u697c5135<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <div class=\"quote\">\u7c73\u8001\u5e08\u539f\u8bdd\uff08\u636e\u9700\u6c42\u7eaa\u8981\uff09\uff1a\u300c\u65e5\u7acb\u662f\u65e5\u7cfb\u8001\u724c\u5b50\uff0c\u8d28\u91cf\u662f\u6ca1\u6709\u8bdd\u8bf4\u7684\uff0c\u6211\u5c31\u662f\u770b\u4e2d\u5b83\u9759\u97f3\u3001\u80fd\u81ea\u6e05\u6d01\uff0c\u8fd8\u6709\u9632\u6f0f\u6c34\u7684\u88c5\u7f6e\uff0c\u7ed9\u5973\u513f\u7684\u5a5a\u623f\u7528\u7740\u624d\u653e\u5fc3\u300d\u2014\u2014\u5a5a\u623f\u4e1a\u4e3b\uff0c\u91cd\u54c1\u8d28\u3001\u91cd\u5065\u5eb7\u3001\u91cd\u5b89\u5fc3\u3002<\/div>\n  <\/div>\n\n  <div id=\"s1-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udca1 \u65b9\u6848\u903b\u8f91\uff1a\u7c73\u8001\u5e08\u6838\u5fc3\u76ee\u6807\u9501\u5b9a\u2014\u2014\u65e5\u7acb\u4e00\u62d6\u56db\u5236\u51b7\u5236\u70ed\u4e00\u4f53\u3001\u5a5a\u623f\u9759\u97f3\u5b89\u7761\u3001\u81ea\u6e05\u6d01\u5065\u5eb7\u3001\u9632\u6f0f\u6c34\u62a4\u88c5\u4fee\u3001\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83c\udfaf \u8212\u9002\u4e0e\u5b89\u5fc3\u76ee\u6807<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u9759\u97f3\u5b89\u7761\uff1a<\/strong>\u5a5a\u623f\u5367\u5ba4\u591c\u95f4\u9700\u8981\u4f4e\u566a\u73af\u5883\uff0c\u65e5\u7acb\u5185\u673a\u8d85\u9759\u97f3\u6863\u4f4d\u4e0d\u6253\u6270\u7761\u7720\uff1b<br>\n        \u2461 <strong>\u81ea\u6e05\u6d01\u5065\u5eb7\uff1a<\/strong>\u957f\u671f\u8fd0\u884c\u4e0d\u79ef\u7070\u53d1\u9709\uff0c\u51fa\u98ce\u66f4\u5e72\u51c0\uff0c\u5229\u4e8e\u5c0f\u4e24\u53e3\u5065\u5eb7\u5c45\u4f4f\uff1b<br>\n        \u2462 <strong>\u9632\u6f0f\u62a4\u88c5\uff1a<\/strong>\u521a\u88c5\u597d\u7684\u540a\u9876\u5730\u677f\u6015\u6ce1\uff0c\u8981\u51b7\u51dd\u6c34\u9632\u6f0f\u914d\u7f6e\u5230\u4f4d\uff1b<br>\n        \u2463 <strong>\u54c1\u8d28\u653e\u5fc3\uff1a<\/strong>\u8ba4\u65e5\u7cfb\u8001\u54c1\u724c\u5e95\u5b50\uff0c\u8d28\u91cf\u7a33\u5b9a\u3001\u5bff\u547d\u957f\u3001\u552e\u540e\u7701\u5fc3\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s1-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u5173\u952e\u7ed3\u8bba\uff1a\u5355\u7cfb\u7edf\u5206\u4f53\u5f0f\u591a\u8054\u673a\u2014\u2014\u7a7a\u8c03\u7528\u65e5\u7acb\u6c1f\u7cfb\u7edf\uff08\u4e00\u62d6\u56db\uff09\uff0c\u5236\u51b7\u5236\u70ed\u4e00\u4f53\u3001\u76f4\u6d41\u53d8\u9891\u8282\u80fd\uff0c\u52d8\u6d4b\u540e\u6309\u623f\u95f4\u9762\u79ef\u7cbe\u51c6\u5339\u914d\u5185\u673a\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\udde9 \u7cfb\u7edf\u603b\u89c8<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u7cfb\u7edf<\/th><th>\u9009\u578b<\/th><th>\u4f5c\u7528<\/th><\/tr>\n        <tr><td>\u7a7a\u8c03<\/td><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u4e00\u62d6\u56db<\/td><td>\u5168\u5c4b\u5236\u51b7\/\u5236\u70ed\uff0c\u76f4\u6d41\u53d8\u9891\u8282\u80fd<\/td><\/tr>\n        <tr><td>\u5f62\u5f0f<\/td><td>\u4e00\u62d6\u56db\u591a\u8054\u673a<\/td><td>\u4e00\u53f0\u5916\u673a\u5e264\u53f0\u5185\u673a\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u5236<\/td><\/tr>\n        <tr><td>\u63a7\u5236<\/td><td>\u5206\u5ba4\u6e29\u63a7<\/td><td>\u5404\u623f\u95f4\u72ec\u7acb\u5f00\u5173\uff0c\u6309\u9700\u4f7f\u7528\u66f4\u7701\u7535<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s1-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udccb \u672c\u8282\u6458\u8981\uff1a\u4ee5\"\u7ec6\u81f4\u8bb2\u89e3+\u5145\u6c2e\u710a\u63a5\u7cbe\u5de5+\u51b7\u51dd\u6c34\u9632\u6f0f\u914d\u7f6e+\u76d1\u7406\u5de1\u68c0\u540c\u6b65\"\u7684\u670d\u52a1\u7406\u5ff5\uff0c\u966a\u770b\u91cd\u54c1\u8d28\u4e0e\u5b89\u5fc3\u7684\u7c73\u8001\u5e08\u5b8c\u6210\u4e00\u62d6\u56db\u9009\u578b\u4e0e\u843d\u5730\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\udd1d \u670d\u52a1\u7406\u5ff5<\/div>\n      <div class=\"card-desc\">\n        \u9762\u5bf9\u4e3a\u5973\u513f\u5a5a\u623f\u88c5\u4fee\u3001\u6700\u91cd\u5b89\u5fc3\u4e0e\u54c1\u8d28\u7684\u4e1a\u4e3b\uff0c\u9f99\u8109\u6696\u901a\u4e0d\u4ee5\u8bdd\u672f\u53d6\u80dc\uff0c\u800c\u662f\uff1a\u2460 \u628a\u7cfb\u7edf\u8bbe\u8ba1\u8bb2\u900f\uff0c\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u539f\u7406\u4e0e\u80fd\u8017\u4e00\u6b21\u6027\u8bf4\u6e05\uff1b\u2461 \u7528<strong>\u5145\u6c2e\u710a\u63a5\u94dc\u7ba1\u5de5\u827a+\u5206\u6b67\u7ba1\u89c4\u8303\u5b89\u88c5+4.0MPa\u4fdd\u538b<\/strong>\u7684\u7cbe\u5de5\u6807\u51c6\uff0c\u628a\"\u5de5\u827a\"\u4ece\u53e3\u53f7\u53d8\u6210\u53ef\u5de1\u68c0\u7684\u8282\u70b9\uff1b\u2462 \u6807\u914d<strong>\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173<\/strong>\u53cc\u9632\u6f0f\u914d\u7f6e\uff0c\u5b88\u62a4\u521a\u88c5\u597d\u7684\u540a\u9876\u5730\u677f\uff1b\u2463 \u6bcf\u4e00\u6b65\u5b89\u88c5\u3001\u5de1\u68c0\u90fd\u540c\u6b65\u7167\u7247\uff0c\u8ba9\u4e1a\u4e3b\u81ea\u5df1\u770b\u89c1\"\u6ca1\u5077\u5de5\u51cf\u6599\"\uff0c\u628a\u7126\u8651\u63d0\u524d\u6e05\u96f6\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S2 \u00b7 \u9700\u6c42\u8bca\u65ad                                                  -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s2\">\n  <div class=\"step-head\">\n    <span class=\"step-num\">S2<\/span>\n    <span class=\"step-label\">\u9700\u6c42\u8bca\u65ad<\/span>\n  <\/div>\n\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s2-tab1')\">\u663e\u6027\u9700\u6c42<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s2-tab2')\">\u9690\u6027\u75db\u70b9<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s2-tab3')\">\u7cfb\u7edf\u56db\u8981\u7d20<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s2-tab4')\">\u8bbe\u8ba1\u4f9d\u636e<\/div>\n  <\/div>\n\n  <div id=\"s2-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83c\udfaf \u843d\u5730\u8981\u70b9\uff1a4\u9879\u663e\u6027\u9700\u6c42\u8986\u76d6\u2014\u2014\u5a5a\u623f\u65b0\u88c5\u3001\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u3001\u9759\u97f3+\u81ea\u6e05\u6d01+\u9632\u6f0f\u6c34\u3001\u8ba4\u65e5\u7cfb\u8001\u724c\u54c1\u8d28\uff0c\u4f53\u73b0\u5a5a\u623f\u6539\u5584\u578b\u4e1a\u4e3b\u7279\u5f81\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcdd \u663e\u6027\u9700\u6c42\u6e05\u5355<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u9700\u6c42<\/th><th>\u5ba2\u6237\u8981\u70b9<\/th><\/tr>\n        <tr><td>1<\/td><td>\u5a5a\u623f\u65b0\u88c5<\/td><td>\u7ed9\u5973\u513f\u51c6\u5907\u5a5a\u623f\uff0c\u91cd\u54c1\u8d28\u91cd\u5b89\u5fc3<\/td><\/tr>\n        <tr><td>2<\/td><td>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u8ba4\u65e5\u7cfb\u8001\u54c1\u724c\uff0c\u4e00\u62d6\u56db\u8986\u76d6\u5168\u5c4b<\/td><\/tr>\n        <tr><td>3<\/td><td>\u9759\u97f3+\u81ea\u6e05\u6d01<\/td><td>\u5367\u5ba4\u5b89\u7761\u3001\u51fa\u98ce\u5e72\u51c0\u5065\u5eb7<\/td><\/tr>\n        <tr><td>4<\/td><td>\u9632\u6f0f\u6c34\u88c5\u7f6e<\/td><td>\u6015\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u88c5\u4fee<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s2-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udccc \u6838\u5fc3\u8981\u70b9\uff1a3\u9879\u9690\u6027\u75db\u70b9\u63ed\u793a\u2014\u2014\u6015\u566a\u97f3\u6270\u7720\u3001\u6015\u51fa\u98ce\u810f\u3001\u6015\u6f0f\u6c34\u6ce1\u88c5\uff0c\u9f99\u8109\u4ee5\u9759\u97f3\u5185\u673a+\u81ea\u6e05\u6d01+\u53cc\u9632\u6f0f\u914d\u7f6e\u9010\u4e00\u5316\u89e3\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udd0d \u9690\u6027\u75db\u70b9<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u566a\u97f3\u7126\u8651\uff1a<\/strong>\u5a5a\u623f\u5367\u5ba4\u591c\u91cc\u8981\u5b89\u9759\uff0c\u6015\u7a7a\u8c03\u5185\u673a\u55e1\u55e1\u58f0\u5f71\u54cd\u7761\u7720\uff1b<br>\n        \u2461 <strong>\u5065\u5eb7\u7126\u8651\uff1a<\/strong>\u957f\u671f\u7528\u7a7a\u8c03\u6015\u79ef\u7070\u53d1\u9709\u3001\u51fa\u98ce\u6709\u5f02\u5473\uff0c\u5f71\u54cd\u5c0f\u4e24\u53e3\u5065\u5eb7\uff1b<br>\n        \u2462 <strong>\u6f0f\u6c34\u7126\u8651\uff1a<\/strong>\u540a\u9876\u5730\u677f\u521a\u88c5\u597d\uff0c\u6700\u6015\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u88c5\u4fee\u3001\u8fd4\u5de5\u6298\u817e\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s2-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udca1 \u65b9\u6848\u903b\u8f91\uff1a\u7a7a\u8c03\uff08\u6c1f\u673a\u56db\u8981\u7d20\uff09\u5339\u914d\u2014\u2014\u70ed\u6e90\uff08\u65e5\u7acb\u5916\u673a\uff09+ \u8f93\u914d\uff08\u94dc\u7ba1\u5206\u6b67\u7ba1\uff09+ \u672b\u7aef\uff084\u53f0\u5185\u673a\uff09+ \u63a7\u5236\uff08\u5206\u5ba4\u6e29\u63a7\uff09+ \u9632\u6f0f\uff08\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\uff09\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\uddf1 \u7cfb\u7edf\u56db\u8981\u7d20\u5339\u914d<\/div>\n      <table class=\"compare-table\">\n        <tbody><tr><th class=\"col-header-a\">\u8981\u7d20<\/th><th class=\"col-header-b\">\u7a7a\u8c03\uff08\u6c1f\u673a\u4e00\u62d6\u56db\uff09<\/th><\/tr>\n        <tr><td>\u70ed\u6e90<\/td><td class=\"col-recommend\">\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u5ba4\u5916\u4e3b\u673a \u00d7 1\u53f0\uff0812.5kW\u00b7\u53cc\u8f6c\u5b50\u00b7APF\u4e00\u7ea75.9\uff09<\/td><\/tr>\n        <tr><td>\u8f93\u914d<\/td><td class=\"col-recommend\">\u51b7\u5a92\u94dc\u7ba1 + \u5206\u6b67\u7ba1\uff08\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5\uff09<\/td><\/tr>\n        <tr><td>\u672b\u7aef<\/td><td class=\"col-recommend\">\u65e5\u7acb\u8212\u4eab\u5185\u673a 4\u53f0\uff08RPIZ-71+36+25+28 FSNAQD\/P\uff09\u00b7 \u5ba2\u9910\u538571+\u4e3b\u536736+\u6b21\u5367125+\u6b21\u5367228<\/td><\/tr>\n        <tr><td>\u63a7\u5236<\/td><td class=\"col-recommend\">\u5206\u5ba4\u6e29\u63a7\uff0c\u4f4e\u540c\u5f00\u7387\u66f4\u7701\u7535<\/td><\/tr>\n        <tr><td>\u9632\u6f0f<\/td><td class=\"col-recommend\">\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173\uff08\u53cc\u9632\u6f0f\uff09<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s2-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u5173\u952e\u7ed3\u8bba\uff1a\u4f9d\u636eGB50736\u56fd\u6807+\u4e24\u6c5f\u6620\u6708\u5a5a\u623f3\u623f2\u5385\u8d1f\u8377\u6d4b\u7b97+\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u5b98\u65b9\u914d\u7f6e\u8868\u5b9a\u7a3f\uff0c\u5916\u673aRAS-125\u62d64\u53f0\u8212\u4eab\u5185\u673a\u8fde\u63a5\u73871.28\u7b26\u5408GB\u533a\u95f4\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcd0 \u8bbe\u8ba1\u4f9d\u636e\uff08\u57fa\u4e8e\u9f99\u8109\u6696\u901a\u5b98\u65b9\u914d\u7f6e\u8868\uff09<\/div>\n      <div class=\"card-desc\">\n        \u2460 \u5e73\u5c42\u00b73\u623f2\u5385\u00b7\u5973\u513f\u5a5a\u623f\uff0c\u6309\u914d\u7f6e\u8868\u51b7\u91cf\u6307\u6807\u5408\u8ba1 <strong>78.8\u33a1<\/strong>\uff08\u5ba2\u9910\u538538.8 + \u4e3b\u536717.2 + \u6b21\u53671 10.2 + \u6b21\u53672 12.6\uff09\uff0c\u5355\u53f0\u5355\u4f4d\u6307\u6807 200\u2013210 W\/\u33a1\uff1b<br>\n        \u2461 \u9009\u578b\u843d\u5730\uff1a\u5916\u673a <strong>RAS-125HRNAQ<\/strong>\uff08\u5236\u51b712.5kW\u00b7\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u00b7APF\u4e00\u7ea75.9\uff09\u62d6 4 \u53f0\u8212\u4eab\u5185\u673a <strong>RPIZ-71+36+25+28 FSNAQD\/P<\/strong>\uff0c\u603b\u51b7\u91cf 16.0kW\uff0c<strong>\u8fde\u63a5\u7387 1.28<\/strong>\uff08\u7ea6 128%\uff0c\u843d\u5728 GB \u5141\u8bb8 50\u2013130% \u533a\u95f4\u4e0a\u9650\u8fb9\u7f18\uff0c\u5a5a\u623f\u540c\u5f00\u7387\u9002\u4e2d\u53ef\u653e\u5fc3\u8fd0\u884c\uff09\uff1b<br>\n        \u2462 \u5a5a\u623f\u91cd\u70b9\u5339\u914d<strong>\u8d85\u9759\u97f3\u5185\u673a<\/strong>\uff08\u4f4e\u566a\u6863\u4f4d 19\u201325 dB(A)\uff09+ <strong>\u81ea\u6e05\u6d01\u529f\u80fd<\/strong>\uff08\u7fc5\u7247\u7ed3\u971c\u2192\u5316\u971c\u5265\u79bb\u7070\u5c18\uff09+ <strong>\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/strong>\uff08\u8fd0\u884c\u66f4\u7a33\u3001\u9707\u52a8\u66f4\u4f4e\uff09\uff0c\u5367\u5ba4\u591c\u95f4\u5b89\u7761\u3001\u51fa\u98ce\u5e72\u51c0\u3001\u957f\u671f\u66f4\u7701\u5fc3\uff1b<br>\n        \u2463 \u8f93\u914d\u8d70\u7ba1\u89c4\u8303\uff0c\u94dc\u7ba1\u5145\u6c2e\u710a\u63a5+\u5206\u6b67\u7ba1\u6c34\u5e73\u5b89\u88c5\uff0c\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u675c\u7edd\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u540a\u9876\u5730\u677f\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u548c\u6210\u672c\u5206\u6790                                         -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s3\">\n  <div class=\"step-head\">\n    <span class=\"step-num\">S3<\/span>\n    <span class=\"step-label\">\u89e3\u51b3\u65b9\u6848\u548c\u6210\u672c\u5206\u6790<\/span>\n  <\/div>\n\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s3-tab1')\">\u65b9\u6848\u5bf9\u6bd4<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s3-tab2')\">\u7cfb\u7edf\u914d\u7f6e<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s3-tab3')\">\u914d\u7f6e\u56fe\u96c6<\/div>\n  <\/div>\n\n  <div id=\"s3-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u5173\u952e\u7ed3\u8bba\uff1a\u7c73\u8001\u5e08\u6700\u7ec8\u9009\u5b9a\u65e5\u7acb\u6c1f\u7cfb\u7edf\u4e00\u62d6\u56db\u591a\u8054\u673a\u2014\u2014\u5236\u51b7\u5236\u70ed\u4e00\u4f53\u3001\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3001\u76f4\u6d41\u53d8\u9891\u8282\u80fd\u3001\u9759\u97f3\u81ea\u6e05\u6d01\u7a81\u51fa\uff0c\u6bd4\u98ce\u7ba1\u673a\/\u67dc\u673a\u65b9\u6848\u66f4\u7f8e\u89c2\u3001\u6bd4\u6c34\u673a\u521d\u6295\u66f4\u53ef\u63a7\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcca \u7cfb\u7edf\u5f62\u5f0f\u5bf9\u6bd4\uff08\u65e5\u7acb\u4e00\u62d6\u56db vs \u5176\u4ed6\uff09<\/div>\n      <table class=\"compare-table\">\n        <tbody><tr><th class=\"col-header-a\">\u5bf9\u6bd4\u9879<\/th><th class=\"col-header-b\">\u7c73\u8001\u5e08\u9009\u5b9a\u00b7\u65e5\u7acb\u4e00\u62d6\u56db\uff08\u2705\uff09<\/th><th class=\"col-header-a\">\u67dc\u673a\/\u98ce\u7ba1\u673a\u65b9\u6848<\/th><\/tr>\n        <tr><td>\u8986\u76d6\u5f62\u5f0f<\/td><td class=\"col-recommend\">\u4e00\u53f0\u5916\u673a\u5e264\u53f0\u5185\u673a\uff0c\u5206\u533a\u72ec\u7acb<\/td><td>\u591a\u53f0\u72ec\u7acb\uff0c\u5360\u7528\u5916\u673a\u4f4d<\/td><\/tr>\n        <tr><td>\u7f8e\u89c2\u5ea6<\/td><td class=\"col-recommend\">\u9690\u85cf\u5f0f\u5185\u673a\uff0c\u540a\u9876\u4e00\u4f53\u5316<\/td><td>\u67dc\u673a\u5360\u5730\u9762\/\u98ce\u7ba1\u673a\u9700\u5927\u540a\u9876<\/td><\/tr>\n        <tr><td>\u9759\u97f3<\/td><td class=\"col-recommend\">\u65e5\u7acb\u8d85\u9759\u97f3\u5185\u673a\uff0c\u5367\u5ba4\u5b89\u7761<\/td><td>\u67dc\u673a\u566a\u58f0\u660e\u663e<\/td><\/tr>\n        <tr><td>\u81ea\u6e05\u6d01<\/td><td class=\"col-recommend\">\u65e5\u7acb\u81ea\u6e05\u6d01\uff0c\u51fa\u98ce\u66f4\u5e72\u51c0<\/td><td>\u591a\u6570\u65e0\u6b64\u529f\u80fd<\/td><\/tr>\n        <tr><td>\u521d\u6295\u6210\u672c<\/td><td class=\"col-recommend\">\u4e00\u62d6\u56db\u6574\u4f53\u53ef\u63a7<\/td><td>\u591a\u53f0\u7d2f\u52a0\u672a\u5fc5\u4f4e<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udca1 \u4e3a\u4ec0\u4e48\u9009\u65e5\u7acb\u4e00\u62d6\u56db<\/div>\n      <div class=\"card-desc\">\n        \u7c73\u8001\u5e08\u4e3a\u5973\u513f\u5a5a\u623f\u88c5\u4fee\uff0c\u5bf9\"\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u3001\u65e5\u7cfb\u54c1\u8d28\"\u6709\u660e\u786e\u8bc9\u6c42\u3002\u4f59\u7231\u82f1\u636e\u6b64\u914d\u7f6e\uff1a<br><br>\n        \u2460 <b>\u4e00\u62d6\u56db\u591a\u8054\u673a<\/b>\uff1a\u65e5\u7acb\u76f4\u6d41\u53d8\u9891\uff0c\u4e00\u53f0\u5916\u673a\u5e264\u53f0\u5185\u673a\uff0c\u5236\u51b7\u5236\u70ed\u4e00\u4f53\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u5236\uff1b<br><br>\n        \u2461 <b>\u8d85\u9759\u97f3<\/b>\uff1a\u65e5\u7acb\u5185\u673a\u4f4e\u566a\u6863\u4f4d\uff0c\u5a5a\u623f\u5367\u5ba4\u591c\u95f4\u5b89\u7761\u4e0d\u88ab\u6253\u6270\uff1b<br><br>\n        \u2462 <b>\u81ea\u6e05\u6d01<\/b>\uff1a\u5185\u673a\u81ea\u6e05\u6d01\u529f\u80fd\uff0c\u957f\u671f\u8fd0\u884c\u4e0d\u79ef\u7070\u53d1\u9709\u3001\u51fa\u98ce\u66f4\u5e72\u51c0\uff1b<br><br>\n        \u2463 <b>\u7cbe\u5de5+\u9632\u6f0f<\/b>\uff1a\u94dc\u7ba1\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5+\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u5b88\u62a4\u521a\u88c5\u597d\u7684\u88c5\u4fee\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s3-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udccb \u672c\u8282\u6458\u8981\uff1a\u7a7a\u8c03\u2014\u2014\u65e5\u7acb\u8212\u4eab\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\uff08\u5916\u673aRAS-125HRNAQ\u62d64\u53f0\u5185\u673a\u00b7\u603b\u51b716.0kW\u00b7\u8fde\u63a5\u73871.28\uff09\uff1b\u63a7\u5236\u2014\u2014\u5206\u5ba4\u6e29\u63a7\uff1b\u9632\u6f0f\u2014\u2014\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\uff08\u5df2\u5b9a\u7a3f\uff09\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\u2744\ufe0f \u7a7a\u8c03\u7cfb\u7edf \u00b7 \u56db\u8981\u7d20<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u8981\u7d20<\/th><th>\u914d\u7f6e<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u70ed\u6e90<\/td><td>\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u5ba4\u5916\u4e3b\u673a \u00d7 1\u53f0<\/td><td>\u76f4\u6d41\u53d8\u9891\uff0cR410A\u73af\u4fdd\u51b7\u5a92\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c\u5236\u51b712.5kW\u00b7APF\u4e00\u7ea75.9<\/td><\/tr>\n        <tr><td>\u8f93\u914d-\u7a7a\u8c03<\/td><td>\u51b7\u5a92\u94dc\u7ba1 + \u5206\u6b67\u7ba1<\/td><td>\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5\u9632\u6c27\u5316\uff0c\u5206\u6b67\u7ba1\u6c34\u5e73\u5b89\u88c5\uff0c\u4fdd\u6e29\u65e0\u6f0f\u5305<\/td><\/tr>\n        <tr><td>\u672b\u7aef-\u7a7a\u8c03<\/td><td>\u65e5\u7acb\u8212\u4eab\u5185\u673a 4\u53f0\uff08RPIZ-71+36+25+28 FSNAQD\/P\uff09<\/td><td>\u5ba2\u9910\u538571+\u4e3b\u536736+\u6b21\u5367\u246025+\u6b21\u5367\u246128\uff0c\u603b\u51b7\u91cf16.0kW<\/td><\/tr>\n        <tr><td>\u63a7\u5236<\/td><td>\u5206\u5ba4\u6e29\u63a7<\/td><td>\u5404\u623f\u95f4\u72ec\u7acb\u5f00\u5173\uff0c\u6309\u9700\u4f7f\u7528\u66f4\u7701\u7535<\/td><\/tr>\n        <tr><td>\u9632\u6f0f<\/td><td>\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173<\/td><td>\u53cc\u91cd\u9632\u6f0f\uff0c\u675c\u7edd\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u88c5\u4fee<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcd0 \u5185\u673a\u914d\u7f6e\u660e\u7ec6\uff08\u4e00\u62d6\u56db \u00b7 4\u53f0\u8212\u4eab\u5185\u673a \u00b7 \u578b\u53f7\u5df2\u5b9a\u7a3f \u00b7 \u9f99\u8109\u6696\u901a\u5b98\u65b9\u914d\u7f6e\u8868\uff09<\/div>\n      <table class=\"compare-table\">\n        <tbody><tr><th class=\"col-header-a\">\u533a\u57df<\/th><th class=\"col-header-b\">\u5236\u51b7\u9762\u79ef\u33a1<\/th><th class=\"col-header-a\">\u5185\u673a\u578b\u53f7\uff08\u65e5\u7acb\u8212\u4eabRPIZ-FSNAQD\/P\uff09<\/th><th class=\"col-header-b\">\u989d\u51b7\uff08W\uff09<\/th><th>\u6570\u91cf<\/th><\/tr>\n        <tr><td>\u4e2d\u95f4\u4f4d\u7f6e \u5ba2\u9910\u5385<\/td><td class=\"col-recommend\">38.8<\/td><td>RPIZ-71FSNAQD\/P\uff08192\u00d71180\u00d7447mm\uff09<\/td><td class=\"col-recommend\">7100<\/td><td>1<\/td><\/tr>\n        <tr><td>\u5185\u5899 \u4e3b\u5367<\/td><td>17.2<\/td><td>RPIZ-36FSNAQD\/P\uff08192\u00d7700\u00d7447mm\uff09<\/td><td>3600<\/td><td>1<\/td><\/tr>\n        <tr><td>\u8fb9\u5899 \u6b21\u53671<\/td><td>10.2<\/td><td>RPIZ-25FSNAQD\/P\uff08192\u00d7550\u00d7447mm\uff09<\/td><td>2500<\/td><td>1<\/td><\/tr>\n        <tr><td>\u8fb9\u5899 \u6b21\u53672<\/td><td>12.6<\/td><td>RPIZ-28FSNAQD\/P\uff08192\u00d7550\u00d7447mm\uff09<\/td><td>2800<\/td><td>1<\/td><\/tr>\n        <tr><td class=\"col-recommend\">\u5408\u8ba1<\/td><td class=\"col-recommend\">\u6309\u51b7\u91cf\u6307\u6807\u5408\u8ba1<br>78.8<\/td><td class=\"col-recommend\">4\u53f0\u8212\u4eab\u5185\u673a<br>\u5168\u7cfb\u8d85\u8584 \u00b7 \u566a\u97f3\u6700\u4f4e 19 dB(A)<\/td><td class=\"col-recommend\">\u603b\u51b7\u91cf16000W<br>\uff0816.0kW\uff09<\/td><td class=\"col-recommend\">\u4e00\u62d6\u56db<\/td><\/tr>\n        <tr><td colspan=\"5\" style=\"background:#fdeede;text-align:left;padding:10px 14px;font-size:13px;color:#B5572B\"><b>\ud83d\udccc \u5916\u673a\u4e0e\u8fde\u63a5\u7387<\/b>\uff1a\u5ba4\u5916\u4e3b\u673a\u65e5\u7acb RAS-125HRNAQ\uff08\u5236\u51b7 12500W \/ 12.5kW\uff09\u4e00\u53f0 \u00b7 \u53cc\u8f6c\u5b50\u538b\u7f29\u673a \u00b7 APF\uff08\u4e00\u7ea7\uff095.9 \u00b7 770\u00d7980\u00d7360mm \u00b7 \u566a\u97f3 54 dB(A) \u00b7 \u8fde\u63a5\u7387 1.28\uff08\u603b\u5185\u51b7 16.0kW \/ \u5916\u51b7 12.5kW \u2248 128%\uff0c\u843d\u5728 GB \u5141\u8bb8 50\u2013130% \u533a\u95f4\u4e0a\u9650\u8fb9\u7f18\uff0c\u5a5a\u623f\u540c\u5f00\u7387\u9002\u4e2d\u53ef\u653e\u5fc3\u8fd0\u884c\uff09\u3002<\/td><\/tr>\n      <\/tbody><\/table>\n      <div class=\"disclaimer\" style=\"margin-top:10px\">\u26a0\ufe0f \u8bda\u5b9e\u62ab\u9732\uff1a\u672c\u9875\u5916\u673a RAS-125HRNAQ \u4e0e4\u53f0\u8212\u4eab\u5185\u673a\uff08RPIZ-71+36+25+28 FSNAQD\/P\uff0c\u603b\u51b7 16.0kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\u5747\u4e3a\u9f99\u8109\u6696\u901a\u5b98\u65b9\u914d\u7f6e\u8868\u5b9a\u7a3f\u6570\u636e\uff1b\u5efa\u7b51\u5957\u5185\u9762\u79ef\u4ee5\u73b0\u573a\u52d8\u6d4b\/\u8865\u7b7e\u5408\u540c\u4e3a\u51c6\uff0c\u672c\u9875\u5236\u51b7\u8ba1\u7b97\u9762\u79ef 78.8\u33a1 \u6765\u81ea\u914d\u7f6e\u8868\"\u6309\u51b7\u91cf\u6307\u6807\"\u8bfb\u6570\uff0c\u4e0d\u7b49\u4e8e\u5efa\u7b51\u9762\u79ef\u3002<\/div>\n    <\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83c\udf1f \u65b9\u6848\u4ecb\u7ecd \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6838\u5fc3\u4eae\u70b9\uff08\u7c73\u8001\u5e08\u770b\u91cd\u9879\uff09<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u7cfb\u7edf<\/th><th>\u4eae\u70b9<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td rowspan=\"5\">\u2744\ufe0f \u7a7a\u8c03<br>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u8d85\u9759\u97f3<\/td><td>\u5185\u673a\u4f4e\u566a\u8fd0\u884c\uff0c\u5a5a\u623f\u5367\u5ba4\u591c\u95f4\u5b89\u7761\u96f6\u5e72\u6270\uff08\u5177\u4f53\u5206\u8d1d\u4ee5\u673a\u578b\u4e3a\u51c6\uff09<\/td><\/tr>\n        <tr><td>\u81ea\u6e05\u6d01<\/td><td>\u5185\u673a\u81ea\u6e05\u6d01\u529f\u80fd\uff0c\u7ed3\u971c\u5265\u79bb\u7070\u5c18\u3001\u5e72\u71e5\u6291\u83cc\uff0c\u957f\u671f\u51fa\u98ce\u66f4\u5e72\u51c0<\/td><\/tr>\n        <tr><td>\u9632\u6f0f\u6c34\u88c5\u7f6e<\/td><td>\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173\uff0c\u53cc\u91cd\u9632\u6f0f\u5b88\u62a4\u540a\u9876\u5730\u677f<\/td><\/tr>\n        <tr><td>\u76f4\u6d41\u53d8\u9891<\/td><td>\u9ad8\u6548\u8282\u80fd\uff0cR410A\u73af\u4fdd\u51b7\u5a92\uff0c\u5236\u51b7\u5236\u70ed\u4e00\u4f53<\/td><\/tr>\n        <tr><td>\u65e5\u7cfb\u54c1\u8d28<\/td><td>\u65e5\u7acb\u65e5\u7cfb\u8001\u54c1\u724c\uff0c\u6838\u5fc3\u90e8\u4ef6\u7a33\u5b9a\uff0c\u8d28\u91cf\u53e3\u7891\u653e\u5fc3<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s3-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83c\udfaf \u843d\u5730\u8981\u70b9\uff1a\u4ee5\u4e0b\u4e3a\u7a7a\u8c03\u914d\u7f6e\u56fe\u4e0e\u65bd\u5de5\u56fe\uff0c\u4fbf\u4e8e\u76f4\u89c2\u6838\u5bf9\u9009\u578b\u4e0e\u8d70\u7ba1\u65b9\u6848\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u51fa\u56fe\u4e3a\u51c6\u3002<\/div>\n\n    <div class=\"photo-phase\">\n      <div class=\"phase-label\">\u2744\ufe0f \u7a7a\u8c03\u914d\u7f6e\u56fe\uff08\u51711\u5f20\uff09<\/div>\n      <div class=\"photo-grid\">\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktpz.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u914d\u7f6e\u56fe\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u65e5\u7acb\u4e00\u62d6\u56db\u914d\u7f6e\u56fe<\/figcaption>\n        <\/figure>\n      <\/div>\n    <\/div>\n\n    <div class=\"content-card\" style=\"border:1px dashed var(--orange);background:#fdf6ef\">\n      <div class=\"card-title\">\ud83d\udccc \u56fe\u7247\u8bf4\u660e<\/div>\n      <div class=\"card-desc\">\u4e0a\u56fe\u4e3a\u7c73\u8001\u5e08\u5bb6\u65e5\u7acb\u8212\u4eab\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db<strong>\u7a7a\u8c03\u914d\u7f6e\u56fe<\/strong>\u3002\u672c\u6848\u4f8b\u5916\u673a RAS-125HRNAQ\uff0812.5kW\uff09+ 4\u53f0\u8212\u4eab\u5185\u673a RPIZ-71\/36\/25\/28 FSNAQD\/P \u578b\u53f7\u4e0e\u8fde\u63a5\u7387 1.28 \u5747\u5df2\u5b9a\u7a3f\uff08\u8be6\u89c1\u4e0a\u65b9\"\u5185\u673a\u914d\u7f6e\u660e\u7ec6\"\u4e0e\u9f99\u8109\u6696\u901a\u5b98\u65b9\u914d\u7f6e\u8868\uff09\uff1b\u5982\u9700\u8865\u5168\uff0c\u5efa\u8bae\u8865\uff1a\u2460 \u6237\u578b\u7b80\u56fe\uff1b\u2461 \u5185\u673a\/\u5916\u673a\u5b89\u88c5\u5b8c\u5de5\u5b9e\u666f\u7167\uff08\u5df2\u542b 5 \u5f20\u65bd\u5de5\u7167 + \u5916\u673a\u4fdd\u538b\u7167\uff09\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u5b98\u65b9\u8be6\u60c5\u5916\u94fe\uff08\u5e38\u9a7b\u53ef\u89c1\uff0c\u7f6e\u4e8e\u7ed3\u8bba\u524d\u7f6e\u4e0b\uff09 -->\n  <div class=\"conclusion-bar\">\u2705 \u7ed3\u8bba\u524d\u7f6e\uff1a\u4ee5\u4e0b\u4e3a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u4ea7\u54c1\u8be6\u60c5\u9875\u5916\u94fe\uff0c\u4fbf\u4e8e\u4e86\u89e3\u53c2\u6570\u4e0e\u9009\u578b\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u65b9\u6848\u4e3a\u51c6\u3002<\/div>\n  <div class=\"content-card\">\n    <div class=\"card-title\">\ud83d\udd17 \u5b98\u65b9\u4ea7\u54c1\u8be6\u60c5\uff08\u5916\u94fe\uff09<\/div>\n    <div class=\"card-desc\" style=\"margin-bottom:8px\">\u9009\u4e2d\u673a\u578b\u7684\u5173\u952e\u53c2\u6570\u5df2\u63d0\u53d6\u81f3\u6b63\u6587\uff08\u89c1\u4e0a\"\u914d\u7f6e\u660e\u7ec6\"\uff09\uff0c\u70b9\u51fb\u4e0b\u65b9\u80f6\u56ca\u53ef\u67e5\u770b\u5b98\u65b9\u5b8c\u6574\u8be6\u60c5\u9875\uff1a<\/div>\n    <a class=\"ext-link\" href=\"https:\/\/longmai-nt.com\/guide\/shuxiang-shuang.html\" target=\"_blank\" rel=\"noopener\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7cfb\u5217\u00b7\u8be6\u89e3 \u2197<\/a>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c                                         -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s4\">\n  <div class=\"step-head\">\n    <span class=\"step-num\">S4<\/span>\n    <span class=\"step-label\">\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c<\/span>\n  <\/div>\n\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s4-tab1')\">\u516d\u6b65\u7cbe\u5de5<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab2')\">\u65bd\u5de5\u7167\u7247<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab3')\">\u7cbe\u5de5\u5bf9\u6bd4<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab4')\">\u8d44\u8d28\u4e0e\u95e8\u5e97<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab5')\">\u552e\u540e\u4fdd\u969c<\/div>\n  <\/div>\n\n  <div id=\"s4-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83d\udccc \u6838\u5fc3\u8981\u70b9\uff1a\u65e5\u7acb\u6388\u6743\u5b89\u88c536\u9879\u8282\u70b9\u9a8c\u6536\u6807\u51c6\uff0c6\u6b65\u7cbe\u5de5\u8986\u76d6\u52d8\u6d4b\u2192\u6c1f\u673a\u94dc\u7ba1\u5de5\u827a\u2192\u8bbe\u5907\u5b89\u88c5\u2192\u53cc\u91cd\u4fdd\u538b\u2192\u8c03\u8bd5\u2192\u9a8c\u6536\uff0c\u76d1\u7406\u5de1\u68c0\u6bcf\u4e00\u6b65\u540c\u6b65\u7167\u7247\u3002<\/div>\n\n    <div class=\"promise-grid\">\n      <div class=\"promise-card\"><div class=\"icon\">\ud83d\udd0d<\/div><div class=\"title\">\u2460 \u5b9a\u4f4d\u653e\u6837<\/div><div class=\"desc\">\u73b0\u573a\u52d8\u6d4b\u786e\u8ba4\u6237\u578b\u4e0e\u8bbe\u5907\u4f4d\uff0c\u653e\u6837\u5185\u673a\u4e0e\u7ba1\u8def\u70b9\u4f4d<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83d\udd27<\/div><div class=\"title\">\u2461 \u6c1f\u673a\u94dc\u7ba1\u5de5\u827a<\/div><div class=\"desc\">\u94dc\u7ba1\u5145\u6c2e\u710a\u63a5+\u5206\u6b67\u7ba1\u6c34\u5e73\u00b11\u00b0+\u4fdd\u6e29\u65e0\u6f0f\u5305<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83d\udca8<\/div><div class=\"title\">\u2462 \u8bbe\u5907\u5b89\u88c5<\/div><div class=\"desc\">4\u53f0\u5185\u673a+\u5916\u673a\u540c\u6b65\u5b89\u88c5\uff0c\u540a\u9876\u9690\u85cf\u5f0f\u5c31\u4f4d<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83e\uddea<\/div><div class=\"title\">\u2463 \u53cc\u91cd\u4fdd\u538b<\/div><div class=\"desc\">\u6c1f\u673a4.0MPa\u4fdd\u538b(R410A)\uff0c\u5408\u683c\u518d\u9690\u853d<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\u2705<\/div><div class=\"title\">\u2464 \u8c03\u8bd5\u9a8c\u6536<\/div><div class=\"desc\">36\u9879\u8282\u70b9\u9a8c\u6536+\u5206\u673a\u8c03\u8bd5+\u5206\u5ba4\u6e29\u63a7\u6d4b\u8bd5<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83d\udcf7<\/div><div class=\"title\">\u2465 \u76d1\u7406\u5de1\u68c0<\/div><div class=\"desc\">\u8fdb\u573a\/\u5b89\u88c5\/\u5de1\u68c0\u6bcf\u6b65\u62cd\u7167\u540c\u6b65\uff0c\u8ba9\u4e1a\u4e3b\u770b\u5f97\u89c1<\/div><\/div>\n    <\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\uddf0 \u7c73\u8001\u5e08\u5bb6\u7279\u522b\u5173\u6ce8\u70b9<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u9632\u6f0f\u4f18\u5148\uff1a<\/strong>\u7c73\u8001\u5e08\u6700\u5728\u610f\"\u51b7\u51dd\u6c34\u6f0f\u4e0d\u6f0f\"\uff0c\u9f99\u8109\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u5e76\u628a\u6392\u6c34\u5761\u5ea6\u3001\u5bc6\u5c01\u4f5c\u4e3a\u5de1\u68c0\u91cd\u70b9\uff1b<br>\n        \u2461 <strong>\u5de5\u827a\u53ef\u89c1\uff1a<\/strong>\u5145\u6c2e\u710a\u63a5+\u5206\u6b67\u7ba1\u89c4\u8303+4.0MPa\u4fdd\u538b\u7684\u7cbe\u5de5\u6807\u51c6\uff0c\u628a\u5de5\u827a\u53d8\u6210\u53ef\u5de1\u68c0\u8282\u70b9\uff1b<br>\n        \u2462 <strong>\u5de1\u68c0\u540c\u6b65\uff1a<\/strong>\u65bd\u5de5\u6bcf\u4e2a\u5173\u952e\u8282\u70b9\uff08\u8fdb\u573a\u3001\u5185\u673a\u540a\u88c5\u3001\u7ba1\u8def\u6577\u8bbe\u3001\u4fdd\u538b\uff09\u90fd\u62cd\u7167\u540c\u6b65\u7ed9\u4e1a\u4e3b\uff0c\u5b89\u88c5\u597d\u540e\u8ba9\u7c73\u8001\u5e08\u771f\u6b63\u653e\u5fc3\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udcf7 \u65bd\u5de5\u7167\u7247\uff08\u771f\u5b9e\u65bd\u5de5\/\u5de1\u68c0\u7167 \u00b7 \u51716\u5f20\uff09\uff1a\u7c73\u8001\u5e08\u5bb6\u4e2d\u592e\u7a7a\u8c03\u8fdb\u573a\u3001\u5b89\u88c5\u3001\u5916\u673a\u4fdd\u538b\u4e0e\u76d1\u7406\u5de1\u68c0\u5b9e\u666f\uff0c\u6bcf\u4e00\u6b65\u5747\u540c\u6b65\u7167\u7247\u3002<\/div>\n\n    <div class=\"photo-phase\">\n      <div class=\"phase-label\">\u2744\ufe0f \u7a7a\u8c03\u65bd\u5de5 \/ \u5de1\u68c0\u7167\u7247\uff08\u51716\u5f20\uff09<\/div>\n      <div class=\"photo-grid\">\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktaz.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u8fdb\u573a\u65bd\u5de5\u7167\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u7a7a\u8c03\u8fdb\u573a\u65bd\u5de5<\/figcaption>\n        <\/figure>\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktaz2.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u7167\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u7a7a\u8c03\u5b89\u88c5<\/figcaption>\n        <\/figure>\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktaz3.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u6577\u8bbe\u7167\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u7ba1\u8def\u6577\u8bbe<\/figcaption>\n        <\/figure>\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktaz4.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u540a\u88c5\u7167\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u5185\u673a\u540a\u88c5<\/figcaption>\n        <\/figure>\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktaz5.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5de1\u68c0\u7167\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u76d1\u7406\u5de1\u68c0<\/figcaption>\n        <\/figure>\n        <figure class=\"photo-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-wjaz.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5916\u673a\u5b89\u88c5\u4e0e\u4fdd\u538b\u7167\" loading=\"lazy\">\n          <figcaption>\u4e24\u6c5f\u6620\u6708-\u7c73\u8001\u5e08-\u5916\u673a\u5b89\u88c5\u4fdd\u538b<\/figcaption>\n        <\/figure>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udca1 \u65b9\u6848\u903b\u8f91\uff1a\u9f99\u8109\u6388\u6743\u5b89\u88c5\u6807\u51c6 vs \u884c\u4e1a\u901a\u914d\u505a\u6cd5\uff0c\u6c1f\u673a\u4e00\u62d6\u56db\u5173\u952e\u5de5\u827a\u5168\u9762\u9886\u5148\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcca \u7cbe\u5de5 vs \u884c\u4e1a\u901a\u914d\u5bf9\u6bd4<\/div>\n      <table class=\"compare-table\">\n        <tbody><tr><th class=\"col-header-a\">\u5de5\u827a\u9879<\/th><th class=\"col-header-b\">\u9f99\u8109\u7cbe\u5de5\uff08\u2705 \u63a8\u8350\uff09<\/th><th class=\"col-header-a\">\u884c\u4e1a\u901a\u914d<\/th><\/tr>\n        <tr><td>\u6c1f\u673a\u94dc\u7ba1<\/td><td class=\"col-recommend\">\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5+\u5206\u6b67\u7ba1\u6c34\u5e73\u00b11\u00b0<\/td><td>\u4e0d\u5145\u6c2e+\u503e\u659c<\/td><\/tr>\n        <tr><td>\u4fdd\u538b\u6d4b\u8bd5<\/td><td class=\"col-recommend\">4.0MPa\u4fdd\u538b\uff08R410A\u6807\u51c6\uff09<\/td><td>\u4f4e\u538b\u6216\u65e0\u4fdd\u538b<\/td><\/tr>\n        <tr><td>\u51b7\u51dd\u6c34\u9632\u62a4<\/td><td class=\"col-recommend\">\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f+\u6392\u6c34\u5761\u5ea6<\/td><td>\u4ec5\u91cd\u529b\u6392\u6c34\u6613\u6f0f<\/td><\/tr>\n        <tr><td>\u5185\u673a\u540a\u88c5<\/td><td class=\"col-recommend\">\u53cc\u87ba\u6bcd\u56fa\u5b9a+\u6c34\u5e73\u6821\u51c6+\u51cf\u9707\u57ab<\/td><td>\u5355\u56fa\u5b9a\u6613\u5171\u632f<\/td><\/tr>\n        <tr><td>\u9a8c\u6536\u6807\u51c6<\/td><td class=\"col-recommend\">36\u9879\u8282\u70b9\u9a8c\u6536+\u5de1\u68c0\u540c\u6b65<\/td><td>\u53e3\u5934\u9a8c\u6536<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u5173\u952e\u7ed3\u8bba\uff1a\u65e5\u7acb\u6388\u6743\u5b89\u88c5+22\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6+\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u4fdd\u969c\u7c73\u8001\u5e08\u5bb6\u7684\u552e\u524d\u552e\u540e\u5168\u94fe\u8def\u670d\u52a1\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83c\udfc5 \u5b98\u65b9\u6388\u6743\u8d44\u8d28<\/div>\n      <div class=\"cert-grid\">\n        <div class=\"cert-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u6388\u6743\u8d44\u8d28\" loading=\"lazy\">\n          <div class=\"label\">\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u6388\u6743<\/div>\n        <\/div>\n        <div class=\"cert-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8d44\u8d28\" loading=\"lazy\">\n          <div class=\"label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/div>\n        <\/div>\n        <div class=\"cert-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u8d44\u8d28\" loading=\"lazy\">\n          <div class=\"label\">\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u8d44\u8d28<\/div>\n        <\/div>\n        <div class=\"cert-item\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u8d44\u8d28\" loading=\"lazy\">\n          <div class=\"label\">\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83c\udfea \u7ebf\u4e0b\u95e8\u5e97\u4fe1\u606f\uff08\u7c73\u8001\u5e08\u5bf9\u63a5\u95e8\u5e97\uff1a\u5357\u5bcc\u68ee\uff09<\/div>\n      <div class=\"info-row\">\n        <div class=\"info-cell\">\n          <div class=\"store-card\">\n            <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n            <div class=\"store-info\">\n              <div class=\"store-name\">\ud83d\udccd \u5357\u5bcc\u68ee\u5e97\uff08\u5bf9\u63a5\u95e8\u5e97\uff09<\/div>\n              <div class=\"store-addr\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<br>\u7535\u8bdd\uff1a028-86131795<\/div>\n            <\/div>\n          <\/div>\n        <\/div>\n        <div class=\"info-cell\">\n          <div class=\"store-card\">\n            <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n            <div class=\"store-info\">\n              <div class=\"store-name\">\ud83d\udccd \u5317\u5bcc\u68ee\u5e97<\/div>\n              <div class=\"store-addr\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7<br>\u7535\u8bdd\uff1a028-65272586<\/div>\n            <\/div>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab5\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udccb \u672c\u8282\u6458\u8981\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6574\u673a\u8d28\u4fdd + \u96f6\u589e\u9879\u627f\u8bfa + \u53cc\u95e8\u5e97\u4e00\u7ad9\u5f0f\u552e\u540e\uff0c\u8ba9\u7c73\u8001\u5e08\u4e3a\u5973\u513f\u51c6\u5907\u7684\u5a5a\u623f\u957f\u671f\u5c45\u4f4f\u66f4\u5b89\u5fc3\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udee1\ufe0f \u8d28\u4fdd\u65b9\u6848<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u8bbe\u5907<\/th><th>\u8d28\u4fdd\u5e74\u9650<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u7a7a\u8c03\uff08\u65e5\u7acb\uff09<\/td><td>\u65e5\u7acb\u6574\u673a\u8d28\u4fdd\uff08\u5177\u4f53\u4ee5\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\uff09<\/td><td>\u538b\u7f29\u673a+\u4e3b\u673a+\u5ba4\u5185\u673a\u5168\u8986\u76d6\uff0c\u5a5a\u623f\u957f\u671f\u81ea\u4f4f\u66f4\u5b89\u5fc3<\/td><\/tr>\n        <tr><td>\u6d3e\u5de5\u670d\u52a1<\/td><td>\u900f\u660e<\/td><td>\u8d28\u4fdd\u671f\u5185\u914d\u4ef6\u514d\u8d39\u66f4\u6362\uff0c\u4ec5\u6536\u6d3e\u5de5\u8f66\u9a6c\u8d39<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\udd1d \u670d\u52a1\u627f\u8bfa<\/div>\n      <div class=\"promise-grid\">\n        <div class=\"promise-card\"><div class=\"icon\">\ud83d\udcde<\/div><div class=\"title\">\u514d\u8d39\u52d8\u6d4b<\/div><div class=\"desc\">\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u53ca\u5468\u8fb9\u514d\u8d39\u4e0a\u95e8\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b<\/div><\/div>\n        <div class=\"promise-card\"><div class=\"icon\">\ud83c\udfd7\ufe0f<\/div><div class=\"title\">\u5de5\u5730\u53c2\u89c2<\/div><div class=\"desc\">\u53ef\u9884\u7ea6\u540c\u6237\u578b\/\u5728\u65bd\u5de5\u5730\u73b0\u573a\u53c2\u89c2<\/div><\/div>\n        <div class=\"promise-card\"><div class=\"icon\">\ud83d\udccb<\/div><div class=\"title\">\u5b9a\u5236\u65b9\u6848<\/div><div class=\"desc\">\u6309\u6237\u578b\u51fa\u4e13\u5c5e\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e0e\u660e\u7ec6\u62a5\u4ef7<\/div><\/div>\n        <div class=\"promise-card\"><div class=\"icon\">\ud83d\udd27<\/div><div class=\"title\">\u96f6\u589e\u9879<\/div><div class=\"desc\">\u7b7e\u7ea6\u4ef7\u5373\u843d\u5730\u4ef7\uff0c\u89c4\u8303\u65bd\u5de5\u65e0\u9690\u5f62\u6536\u8d39<\/div><\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S5 \u00b7 \u9a8c\u8bc1\u8fed\u4ee3                                                  -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s5\">\n  <div class=\"step-head\">\n    <span class=\"step-num\">S5<\/span>\n    <span class=\"step-label\">\u9a8c\u8bc1\u8fed\u4ee3<\/span>\n  <\/div>\n\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s5-tab1')\">\u6848\u4f8b\u590d\u76d8<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab2')\">\u4e13\u4e1a\u4e3b\u5f20<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab3')\">\u98ce\u9669\u544a\u77e5<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab4')\">\u4f7f\u7528\u8d34\u58eb<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab5')\">\u9ad8\u9891\u95ee\u7b54<\/div>\n  <\/div>\n\n  <div id=\"s5-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83c\udfaf \u843d\u5730\u8981\u70b9\uff1a\u4ece\u5357\u5bcc\u68ee\u901b\u5e97\u5bf9\u6bd4\u2192\u7ec6\u81f4\u8bb2\u89e3\u9759\u97f3\u81ea\u6e05\u6d01\u9632\u6f0f\u2192\u4e00\u62d6\u56db\u65b9\u6848\u2192\u8fdb\u573a\u65bd\u5de5\u2192\u76d1\u7406\u5de1\u68c0\u540c\u6b65\u2192\u5b89\u88c5\u6ee1\u610f\uff0c\u5168\u7a0b\u4f59\u7231\u82f1\u5bf9\u63a5\uff0c\u4ee5\"\u54c1\u8d28\u8bb2\u89e3+\u7cbe\u5de5\u53ef\u89c1+\u53cc\u9632\u6f0f\"\u843d\u5b9a\u7c73\u8001\u5e08\u5a5a\u623f\u7a7a\u8c03\u3002<\/div>\n\n    <div class=\"timeline\">\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u5357\u5bcc\u68ee\u901b\u5e97<\/div><div class=\"timeline-detail\">\u7c73\u8001\u5e08\u4e3a\u5973\u513f\u5a5a\u623f\u6765\u5357\u5bcc\u68ee\u901b\u6696\u901a\uff0c\u5bf9\u6bd4\u591a\u5bb6\uff0c\u770b\u91cd\u9759\u97f3\/\u81ea\u6e05\u6d01\/\u9632\u6f0f<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u65b9\u6848\u8bb2\u89e3<\/div><div class=\"timeline-detail\">\u9f99\u8109\u9500\u552e\u628a\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u539f\u7406\u4e0e\u80fd\u8017\u4e00\u6b21\u6027\u8bb2\u6e05<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u914d\u7f6e\u6572\u5b9a<\/div><div class=\"timeline-detail\">\u9009\u5b9a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff0c\u5916\u673a\u62d64\u53f0\u5185\u673a\u5206\u533a\u8986\u76d6\u5168\u5c4b<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-label\">\u8fdb\u573a\u65bd\u5de5<\/div><div class=\"timeline-detail\">\u5145\u6c2e\u710a\u63a5\u94dc\u7ba1+\u5206\u6b67\u7ba1\u89c4\u8303+\u5185\u673a\u540a\u88c5\uff0c4.0MPa\u4fdd\u538b\u5408\u683c<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u5de1\u68c0\u6ee1\u610f<\/div><div class=\"timeline-detail\">\u6bcf\u6b65\u76d1\u7406\u5de1\u68c0\u62cd\u7167\u540c\u6b65\uff0c\u53cc\u9632\u6f0f\u914d\u7f6e\u8ba9\u7c73\u8001\u5e08\u5f7b\u5e95\u653e\u5fc3<\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\u2705 \u7ed3\u8bba\u524d\u7f6e\uff1a4\u6761\u4e13\u4e1a\u4e3b\u5f20\u2014\u2014\u4e00\u62d6\u56db\u591a\u8054\u673a\u5404\u53d6\u6240\u957f\u3001\u65e5\u7acb\u9759\u97f3\u81ea\u6e05\u6d01\u3001\u53cc\u9632\u6f0f\u62a4\u88c5\u4fee\u3001\u7cbe\u5de5\u5de5\u827a\u53ef\u5de1\u68c0\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udca1 \u4e13\u4e1a\u4e3b\u5f20<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u4e00\u62d6\u56db\u591a\u8054\u673a<\/strong>\uff1a\u4e00\u53f0\u5916\u673a\u5e264\u53f0\u5185\u673a\uff0c\u5206\u533a\u72ec\u7acb\u3001\u7f8e\u89c2\u7701\u5730\uff1b<br>\n        \u2461 <strong>\u9759\u97f3\u81ea\u6e05\u6d01<\/strong>\uff1a\u65e5\u7acb\u5185\u673a\u4f4e\u566a\u5b89\u7761+\u81ea\u6e05\u6d01\u51fa\u98ce\u5e72\u51c0\uff0c\u5a5a\u623f\u5065\u5eb7\u8212\u9002\uff1b<br>\n        \u2462 <strong>\u53cc\u9632\u6f0f\u62a4\u88c5<\/strong>\uff1a\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\uff0c\u5b88\u62a4\u521a\u88c5\u597d\u7684\u540a\u9876\u5730\u677f\uff1b<br>\n        \u2463 <strong>\u7cbe\u5de5\u53ef\u5de1\u68c0<\/strong>\uff1a\u5145\u6c2e\u710a\u63a5+4.0MPa\u4fdd\u538b+\u76d1\u7406\u5de1\u68c0\u540c\u6b65\uff0c\u5de5\u827a\u770b\u5f97\u89c1\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udccc \u6838\u5fc3\u8981\u70b9\uff1a\u57fa\u4e8e\u5a5a\u623f\u5b89\u88c5\u540e\u63d0\u793a\uff0c4\u6761\u98ce\u9669\u63d0\u9192\uff0c\u4fdd\u969c\u4f7f\u7528\u4f53\u9a8c\u4e0e\u8bbe\u5907\u5bff\u547d\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\u26a0\ufe0f \u98ce\u9669\u544a\u77e5\uff08\u636e\u5b89\u88c5\u540e\u63d0\u793a\uff09<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u51b7\u51dd\u6c34<\/strong>\uff1a\u7a7a\u8c03\u6392\u6c34\u7ba1\u8bf7\u52ff\u62ac\u9ad8\uff0c\u907f\u514d\u540e\u671f\u4f7f\u7528\u6f0f\u6c34\uff0c\u6ce8\u610f\u6210\u54c1\u4fdd\u62a4\uff1b<br>\n        \u2461 <strong>\u7535\u6e90\u9884\u7559<\/strong>\uff1a\u4e3b\u673a\u97001\u4e2a220V\u7a7a\u6c14\u5f00\u5173\uff08\u5177\u4f53\u89c4\u683c\u4ee5\u673a\u578b\u4e3a\u51c6\uff09\uff0c\u5185\u673a\u9700\u72ec\u7acb\u7a7a\u5f00\uff0c\u505a\u914d\u7535\u7bb1\u65f6\u914d\u5907\uff0c\u4e3b\u673a\u7535\u6e90\u653e\u4e3b\u673a\u4f4d\u4e13\u7ebf\u4e13\u7528\uff1b<br>\n        \u2462 <strong>\u98ce\u53e3\u4e0e\u68c0\u4fee\u53e3<\/strong>\uff1a\u6728\u5320\u6240\u5f00\u98ce\u53e3\/\u56de\u98ce\u53e3\/\u68c0\u4fee\u53e3\u987b\u6b63\u5bf9\u673a\u5668\u6807\u6ce8\u5c3a\u5bf8\uff0c\u56de\u98ce\u53e3\u56db\u5468\u52a0\u6728\u6761\u56fa\u5b9a\uff1b\u67dc\u4f53\u6321\u4f4f\u56de\u98ce\u53e3\u5904\u987b\u7559\u6d3b\u52a8\u68c0\u4fee\u53e3\uff1b<br>\n        \u2463 <strong>\u957f\u98ce\u53e3<\/strong>\uff1a\u82e5\u505a\u52a0\u957f\u98ce\u53e3\uff0c\u5047\u98ce\u53e3\u5185\u90e8\u52a0\u6321\u677f\u505a\u6210\u51f9\u69fd\u5e76\u6d82\u9ed1\uff0c\u6df1\u5ea6\u8981\u6c425\u516c\u5206\u4ee5\u4e0a\uff0c\u5426\u5219\u98ce\u53e3\u88c5\u4e0d\u4e0a\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udca1 \u65b9\u6848\u903b\u8f91\uff1a\u4e2d\u592e\u7a7a\u8c03\u4f7f\u7528\u8981\u70b9\uff0c\u5408\u7406\u4f7f\u7528\u53ef\u5ef6\u957f\u8bbe\u5907\u5bff\u547d\u3001\u63d0\u5347\u8212\u9002\u5ea6\u3001\u8282\u80fd\u7701\u7535\u3002<\/div>\n\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udccc \u4f7f\u7528\u8d34\u58eb\uff08\u636e\u6863\u6848\u5b89\u88c5\u540e\u63d0\u793a\uff09<\/div>\n      <div class=\"card-desc\">\n        \u2460 \u5bb6\u5177\u88c5\u597d\u540e\u901a\u77e5\u91cf\u98ce\u53e3\u5c3a\u5bf8\u3001\u8c03\u8bd5\uff0c\u786e\u4fdd\u5236\u51b7\u5236\u70ed\u6548\u679c\uff1b<br>\n        \u2461 \u7a7a\u8c03\u5185\u673a\u81ea\u6e05\u6d01\u529f\u80fd\u5b9a\u671f\u542f\u7528\uff0c\u4fdd\u6301\u5236\u51b7\u6548\u679c\u4e0e\u7a7a\u6c14\u6e05\u65b0\uff1b<br>\n        \u2462 \u6362\u5b63\u9996\u6b21\u5f00\u673a\u524d\u53ef\u8054\u7cfb\u9f99\u8109\u6696\u901a\u5de1\u68c0\uff0c\u786e\u4fdd\u7cfb\u7edf\u72b6\u6001\u826f\u597d\uff1b<br>\n        \u2463 \u5404\u623f\u95f4\u5206\u5ba4\u6e29\u63a7\uff0c\u65e0\u4eba\u623f\u95f4\u53ef\u5173\uff0c\u4f4e\u540c\u5f00\u7387\u66f4\u7701\u7535\uff1b<br>\n        \u2464 \u80fd\u8017\u5b9e\u6d4b\u6570\u636e\u5f85\u7c73\u8001\u5e08\u5165\u4f4f\u540e\u66f4\u65b0\uff08\u672c\u6848\u5df2\u65bd\u5de5\uff0c\u6708\u5ea6\u8fd0\u884c\u7535\u8d39\u5c06\u4ee5\u540c\u6237\u578b\u6d4b\u7b97+\u5b9e\u9645\u6284\u8868\u8865\u5145\uff09\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab5\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u5173\u952e\u7ed3\u8bba\uff1a5\u6761FAQ\u8986\u76d6\u4e00\u62d6\u56db\u2192\u9759\u97f3\u81ea\u6e05\u6d01\u2192\u53cc\u9632\u6f0f\u2192\u53cc\u6d41\u95e8\u5e97\u2192\u8d28\u4fdd\uff0c\u542b\u4e24\u6c5f\u6620\u6708\u672c\u5730\u5316\u95ee\u9898\u3002<\/div>\n\n    <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u88c5\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u5927\u6982\u591a\u5c11\u94b1\uff1f<\/div><div class=\"faq-a\">\u7c73\u8001\u5e08\u5bb6\u4e3a\u5973\u513f\u5a5a\u623f\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff08\u5ba4\u5916\u4e3b\u673a\u62d64\u53f0\u5185\u673a\uff09\uff0c\u5177\u4f53\u62a5\u4ef7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u4e3a\u51c6\uff0c\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u4e13\u5c5e\u65b9\u6848\uff0c\u7b7e\u7ea6\u4ef7\u5373\u843d\u5730\u4ef7\u65e0\u589e\u9879\u3002<\/div><\/div>\n    <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u7c73\u8001\u5e08\u4e3a\u4ec0\u4e48\u770b\u91cd\u65e5\u7acb\u7684\u9759\u97f3\u548c\u81ea\u6e05\u6d01\uff1f<\/div><div class=\"faq-a\">\u5a5a\u623f\u5367\u5ba4\u591c\u95f4\u9700\u8981\u5b89\u9759\u73af\u5883\uff0c\u65e5\u7acb\u5185\u673a\u8d85\u9759\u97f3\u6863\u4f4d\u4e0d\u6253\u6270\u7761\u7720\uff1b\u81ea\u6e05\u6d01\u529f\u80fd\u8ba9\u957f\u671f\u8fd0\u884c\u4e0d\u79ef\u7070\u53d1\u9709\u3001\u51fa\u98ce\u66f4\u5e72\u51c0\uff0c\u5229\u4e8e\u5c0f\u4e24\u53e3\u5065\u5eb7\u5c45\u4f4f\uff0c\u8fd9\u6b63\u662f\u7c73\u8001\u5e08\u4e3a\u5973\u513f\u5a5a\u623f\u8003\u91cf\u7684\u6838\u5fc3\u70b9\u3002<\/div><\/div>\n    <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u9f99\u8109\u7684\u9632\u6f0f\u6c34\u88c5\u7f6e\u662f\u600e\u4e48\u505a\u7684\uff1f<\/div><div class=\"faq-a\">\u672c\u6848\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\u914d\u7f6e\uff0c\u914d\u5408\u89c4\u8303\u7684\u6392\u6c34\u5761\u5ea6\u4e0e\u5bc6\u5c01\u5de5\u827a\uff0c\u4ece\u6839\u6e90\u675c\u7edd\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u540a\u9876\u5730\u677f\uff0c\u7c73\u8001\u5e08\u6700\u5728\u610f\u7684\"\u6f0f\u6c34\u7126\u8651\"\u7531\u6b64\u5316\u89e3\u3002<\/div><\/div>\n    <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u9f99\u8109\u7684\u5b89\u88c5\u5de5\u827a\u6709\u4ec0\u4e48\u4e0d\u4e00\u6837\uff1f<\/div><div class=\"faq-a\">\u91c7\u7528\u94dc\u7ba1\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5+\u5206\u6b67\u7ba1\u6c34\u5e73\u00b11\u00b0+\u4fdd\u6e29\u65e0\u6f0f\u5305\uff0c\u6c1f\u673a4.0MPa\u4fdd\u538b\uff08R410A\u6807\u51c6\uff09\uff0c36\u9879\u8282\u70b9\u9a8c\u6536\uff0c\u4e14\u6bcf\u6b65\u76d1\u7406\u5de1\u68c0\u62cd\u7167\u540c\u6b65\uff0c\u5de5\u827a\u770b\u5f97\u89c1\u3001\u4e0d\u5077\u5de5\u3002<\/div><\/div>\n    <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u4e24\u6c5f\u6620\u6708\u9644\u8fd1\u6709\u9f99\u8109\u95e8\u5e97\u5417\uff1f<\/div><div class=\"faq-a\">\u7c73\u8001\u5e08\u5bf9\u63a5\u95e8\u5e97\u4e3a\u5357\u5bcc\u68ee\u5e97\uff0c\u4f4d\u4e8e\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\uff08\u7535\u8bdd028-86131795\uff09\uff1b\u5317\u5bcc\u68ee\u5e97\u4f4d\u4e8e\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7\uff08\u7535\u8bdd028-65272586\uff09\uff0c\u4e24\u6c5f\u6620\u6708\u4e1a\u4e3b\u53ef\u5c31\u8fd1\u5230\u5e97\u8be6\u8be2\u3002<\/div><\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S6 \u00b7 \u95e8\u5e97\u6388\u6743\u4e0e\u672c\u5730\u670d\u52a1                                         -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s6\">\n  <div class=\"step-head\">\n    <span class=\"step-num\">S6<\/span>\n    <span class=\"step-label\">\u95e8\u5e97\u6388\u6743\u4e0e\u672c\u5730\u670d\u52a1<\/span>\n  <\/div>\n\n  <div class=\"conclusion-bar\">\ud83d\udccb \u672c\u8282\u6458\u8981\uff1a\u65e5\u7acb\u6388\u6743\u5b89\u88c5 + 22\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6 + \u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u4fdd\u969c\u7c73\u8001\u5e08\u5bb6\u7684\u552e\u524d\u552e\u540e\u5168\u94fe\u8def\u670d\u52a1\u3002<\/div>\n\n  <div class=\"content-card\">\n    <div class=\"card-title\">\ud83c\udfc5 \u5b98\u65b9\u6388\u6743\u8d44\u8d28<\/div>\n    <div class=\"cert-grid\">\n      <div class=\"cert-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u6388\u6743\u8d44\u8d28\" loading=\"lazy\">\n        <div class=\"label\">\u65e5\u7acb\u7279\u9080\u5b89\u88c5\u6388\u6743<\/div>\n      <\/div>\n      <div class=\"cert-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\u8d44\u8d28\" loading=\"lazy\">\n        <div class=\"label\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/div>\n      <\/div>\n      <div class=\"cert-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u8d44\u8d28\" loading=\"lazy\">\n        <div class=\"label\">\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\u8d44\u8d28<\/div>\n      <\/div>\n      <div class=\"cert-item\">\n        <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u8d44\u8d28\" loading=\"lazy\">\n        <div class=\"label\">\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"content-card\">\n    <div class=\"card-title\">\ud83c\udfea \u7ebf\u4e0b\u95e8\u5e97\u4fe1\u606f\uff08\u7c73\u8001\u5e08\u5bf9\u63a5\u95e8\u5e97\uff1a\u5357\u5bcc\u68ee\uff09<\/div>\n    <div class=\"info-row\">\n      <div class=\"info-cell\">\n        <div class=\"store-card\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n          <div class=\"store-info\">\n            <div class=\"store-name\">\ud83d\udccd \u5357\u5bcc\u68ee\u5e97\uff08\u5bf9\u63a5\u95e8\u5e97\uff09<\/div>\n            <div class=\"store-addr\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<br>\u7535\u8bdd\uff1a028-86131795<\/div>\n          <\/div>\n        <\/div>\n      <\/div>\n      <div class=\"info-cell\">\n        <div class=\"store-card\">\n          <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n          <div class=\"store-info\">\n            <div class=\"store-name\">\ud83d\udccd \u5317\u5bcc\u68ee\u5e97<\/div>\n            <div class=\"store-addr\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7<br>\u7535\u8bdd\uff1a028-65272586<\/div>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"disclaimer\">\n    <strong>\ud83d\udce2 \u9690\u79c1\u4e0e\u5408\u89c4\u58f0\u660e<\/strong><br>\n    1. \u672c\u6848\u4f8b\u4e2d\u5ba2\u6237\u59d3\u540d\u4ec5\u4fdd\u7559\u59d3\u6c0f+\u8001\u5e08\u79f0\u547c\uff0c\u4e0d\u5c55\u793a\u5168\u540d\u548c\u5177\u4f53\u623f\u53f7<br>\n    2. \u672c\u6848\u9020\u4ef7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\uff0c\u5177\u4f53\u91d1\u989d\u4e0d\u516c\u793a<br>\n    3. \u5ba2\u6237\u5bf9\u8bdd\u5185\u5bb9\u636e\u9700\u6c42\u7eaa\u8981\u91cd\u6784\uff0c\u5df2\u505a\u9690\u79c1\u4fdd\u62a4\u5904\u7406\uff0c\u5f85\u8865\u771f\u5b9e\u539f\u6587<br>\n    4. \u672c\u6848\u4f8b\u7531\u9f99\u8109\u6696\u901a\u63d0\u4f9b\uff0c\u4ec5\u4f9b\u53c2\u8003\uff0c\u4e0d\u6784\u6210\u5408\u540c\u627f\u8bfa<br>\n    <br>\n    <strong>\u26a0\ufe0f \u975e\u7981\u7528\u8bcd\u58f0\u660e<\/strong>\uff1a\u672c\u9875\u9762\u4e0d\u542b\u6781\u9650\u8bcd\u4e0e\u7edd\u5bf9\u5316\u7528\u8bed\uff0c\u6240\u6709\u80fd\u8017\u6570\u636e\u5747\u6807\u6ce8\u300c\u672c\u5c0f\u533a\u5b9e\u6d4b\/\u540c\u6237\u578b\u6d4b\u7b97\u300d\u524d\u7f00\n  <\/div>\n<\/section>\n\n<!-- ===== CTA ===== -->\n<section style=\"max-width:1100px;margin:24px auto;padding:20px 24px;text-align:center;background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow)\">\n  <div style=\"font-size:18px;font-weight:700;color:var(--deep-orange);margin-bottom:8px\">\ud83d\udcac \u514d\u8d39\u54a8\u8be2 \u00b7 \u540c\u6237\u578b\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u5b9a\u5236<\/div>\n  <div style=\"font-size:13px;color:var(--text-gray);margin-bottom:12px\">\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848<\/div>\n  <div style=\"display:flex;justify-content:center;gap:12px;flex-wrap:wrap;margin-bottom:14px\">\n    <span style=\"display:inline-block;padding:10px 20px;border-radius:24px;background:linear-gradient(135deg,var(--deep-orange),var(--orange));color:#fff;font-size:14px;font-weight:700\">\ud83d\udccf \u514d\u8d39\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b<\/span>\n    <span style=\"display:inline-block;padding:10px 20px;border-radius:24px;border:1.5px solid var(--orange);color:var(--deep-orange);font-size:14px;font-weight:700;background:var(--orange-soft)\">\ud83c\udfd7\ufe0f \u9884\u7ea6\u5de5\u5730\u53c2\u89c2<\/span>\n    <span style=\"display:inline-block;padding:10px 20px;border-radius:24px;border:1.5px solid var(--orange);color:var(--deep-orange);font-size:14px;font-weight:700;background:var(--orange-soft)\">\ud83d\udccb \u4e0a\u95e8\u5b9a\u5236\u65b9\u6848<\/span>\n  <\/div>\n  <div style=\"font-size:16px;font-weight:700;color:var(--orange)\">\ud83d\udcde \u4f59\u7231\u82f1 13908183204\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/div>\n  <div style=\"font-size:12px;color:var(--text-light);margin-top:8px\">\u5357\u5bcc\u68ee\u5e97\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f73\u697cA348 \uff5c \u5317\u5bcc\u68ee\u5e97\uff1a\u6210\u534e\u533a5\u697c5135<\/div>\n<\/section>\n\n<!-- ===== \u5173\u952e\u8bcd\u9690\u85cf\u5757 ===== -->\n<div class=\"keywords-block\">\n\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u53cc\u6d41\u6c1f\u7cfb\u7edf\u591a\u8054\u673a \u65e5\u7acb\u4e00\u62d6\u56db \u9f99\u8109\u6696\u901a22\u5e74\u65e5\u7acb\u6388\u6743 \u53cc\u6d41\u4e2d\u592e\u7a7a\u8c03 \u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03 \u65e5\u7acb\u9759\u97f3\u81ea\u6e05\u6d01\n<\/div>\n\n<!-- ===== \u9875\u811a ===== -->\n<footer style=\"text-align:center;padding:20px;font-size:12px;color:var(--text-light);border-top:1px solid #eee\">\n  \u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6 \u00b7 \u81ea2004\u5e74\u6210\u7acb\u4ee5\u6765\u59cb\u7ec8\u4ee5\u6b63\u89c4\u6388\u6743\u3001\u89c4\u8303\u65bd\u5de5\u4e3a\u51c6\u5219<br>\n  \u5357\u5bcc\u68ee\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f73\u697cA348 \uff5c \u5317\u5bcc\u68ee\uff1a\u6210\u534e\u533a5\u697cA5135<br>\n  \u6848\u4f8b\u5236\u4f5c\uff1a\u6768\u8212\u6587<br>\n  \u00a9 2026 \u9f99\u8109\u6696\u901a longmai-nt.com\n<\/footer>\n\n<script>\n\/\/ \u6eda\u52a8\u5230\u6307\u5b9a\u533a\u6bb5\nfunction scrollToSection(id){\n  document.getElementById(id).scrollIntoView({behavior:'smooth',block:'start'});\n  document.querySelectorAll('.toc-btn').forEach(b=>b.classList.remove('active'));\n  event.target.classList.add('active');\n}\n\n\/\/ \u5207\u6362Tab\u9762\u677f\nfunction switchTab(tabEl,panelId){\n  var section=tabEl.closest('.step-section');\n  section.querySelectorAll('.section-tab').forEach(t=>t.classList.remove('active'));\n  tabEl.classList.add('active');\n  section.querySelectorAll('.tab-panel').forEach(p=>p.style.display='none');\n  document.getElementById(panelId).style.display='block';\n}\n\n\/\/ \u7ffb\u8f6c\u5361\nfunction flipCard(card){card.classList.toggle('flipped')}\n\n\/\/ \u6eda\u52a8\u65f6\u81ea\u52a8\u66f4\u65b0\u5bfc\u822a\u9ad8\u4eae\nwindow.addEventListener('scroll',function(){\n  var sections=document.querySelectorAll('.step-section');\n  var btns=document.querySelectorAll('.toc-btn');\n  var current='';\n  sections.forEach(function(s){\n    if(window.scrollY>=s.offsetTop-80) current=s.id;\n  });\n  btns.forEach(function(b){\n    b.classList.remove('active');\n    if(b.getAttribute('onclick')&&b.getAttribute('onclick').indexOf(current)>-1) b.classList.add('active');\n  });\n});\n<\/script>\n\n<!-- ===== JSON-LD \u7ed3\u6784\u5316\u6570\u636e\uff084\u4ef6\u5957\u6210\u54c1\u4ee3\u7801 \u00b7 \u9875\u9762\u5e95\u90e8\u9690\u5f62\uff09 ===== -->\n<!-- 1.Article \u6587\u7ae0\u7ed3\u6784\u5316 -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"Article\",\n  \"headline\":\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\uff5c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b-\u9f99\u8109\u6696\u901a\",\n  \"description\":\"\u9f99\u8109\u6696\u901a\u843d\u5730\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b\uff0c\u770b\u91cd\u65e5\u7acb\u9759\u97f3\u4e0e\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u6c34\u88c5\u7f6e\uff0c\u65e5\u7cfb\u8001\u724c\u54c1\u8d28\u653e\u5fc3\uff0c\u5357\u5bcc\u68ee\u95e8\u5e97\u5bf9\u63a5\uff0c\u5145\u6c2e\u710a\u63a5\u94dc\u7ba1\u5de5\u827a+4.0MPa\u4fdd\u538b+\u76d1\u7406\u5de1\u68c0\u540c\u6b65\uff0c\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u5a5a\u623f\u4e1a\u4e3b\u7cbe\u5de5\u65bd\u5de5\u6848\u4f8b\u3002\",\n  \"author\":{\"@type\":\"Person\",\"name\":\"\u4f59\u7231\u82f1\",\"jobTitle\":\"\u9500\u552e\u987e\u95ee\"},\n  \"publisher\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\"},\n  \"datePublished\":\"2026-08-01\",\n  \"dateModified\":\"2026-08-18\",\n  \"keywords\":\"\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03,\u53cc\u6d41\u6c1f\u7cfb\u7edf\u591a\u8054\u673a,\u65e5\u7acb\u4e00\u62d6\u56db,\u9f99\u8109\u6696\u901a,22\u5e74\u65e5\u7acb\u6388\u6743\",\n  \"articleBody\":\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\uff08\u4e8c\u6c5f\u5bfaTOD\uff09\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u65b0\u88c5\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u2014\u2014\u65e5\u7acb\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\uff0c\u5ba4\u5916\u4e3b\u673a\u62d64\u53f0\u5ba4\u5185\u673a\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u4e1a\u4e3b\u4e3a\u5973\u513f\u5a5a\u623f\u88c5\u4fee\uff0c\u6838\u5fc3\u8bc9\u6c42\u662f\u65e5\u7acb\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u9632\u6f0f\u6c34\u88c5\u7f6e\u4e0e\u65e5\u7cfb\u8001\u724c\u54c1\u8d28\u653e\u5fc3\u3002\u672c\u6848\u4ee5\u4e00\u62d6\u56db+\u5145\u6c2e\u710a\u63a5\u94dc\u7ba1\u5de5\u827a+\u51b7\u51dd\u6c34\u53cc\u9632\u6f0f+\u76d1\u7406\u5de1\u68c0\u540c\u6b65\u843d\u5730\uff0c22\u5e74\u672c\u571f\u7cbe\u5de5\u65bd\u5de5\u3002\",\n  \"locationCreated\":{\"@type\":\"Place\",\"name\":\"\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\"}\n}\n<\/script>\n\n<!-- 2.FAQPage \u95ee\u7b54\u7ed3\u6784\u5316 -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u88c5\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u5927\u6982\u591a\u5c11\u94b1\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u7c73\u8001\u5e08\u5bb6\u4e3a\u5973\u513f\u5a5a\u623f\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\uff08\u5ba4\u5916\u4e3b\u673a\u62d64\u53f0\u5185\u673a\uff09\uff0c\u5177\u4f53\u62a5\u4ef7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u4e3a\u51c6\uff0c\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u4e13\u5c5e\u65b9\u6848\uff0c\u7b7e\u7ea6\u4ef7\u5373\u843d\u5730\u4ef7\u65e0\u589e\u9879\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u7c73\u8001\u5e08\u4e3a\u4ec0\u4e48\u770b\u91cd\u65e5\u7acb\u7684\u9759\u97f3\u548c\u81ea\u6e05\u6d01\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5a5a\u623f\u5367\u5ba4\u591c\u95f4\u9700\u8981\u5b89\u9759\u73af\u5883\uff0c\u65e5\u7acb\u5185\u673a\u8d85\u9759\u97f3\u6863\u4f4d\u4e0d\u6253\u6270\u7761\u7720\uff1b\u81ea\u6e05\u6d01\u529f\u80fd\u8ba9\u957f\u671f\u8fd0\u884c\u4e0d\u79ef\u7070\u53d1\u9709\u3001\u51fa\u98ce\u66f4\u5e72\u51c0\uff0c\u5229\u4e8e\u5c0f\u4e24\u53e3\u5065\u5eb7\u5c45\u4f4f\uff0c\u8fd9\u6b63\u662f\u7c73\u8001\u5e08\u4e3a\u5973\u513f\u5a5a\u623f\u8003\u91cf\u7684\u6838\u5fc3\u70b9\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u9f99\u8109\u7684\u9632\u6f0f\u6c34\u88c5\u7f6e\u662f\u600e\u4e48\u505a\u7684\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u672c\u6848\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5+\u6c34\u4f4d\u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\u914d\u7f6e\uff0c\u914d\u5408\u89c4\u8303\u7684\u6392\u6c34\u5761\u5ea6\u4e0e\u5bc6\u5c01\u5de5\u827a\uff0c\u4ece\u6839\u6e90\u675c\u7edd\u51b7\u51dd\u6c34\u6e17\u6f0f\u6ce1\u574f\u540a\u9876\u5730\u677f\uff0c\u7c73\u8001\u5e08\u6700\u5728\u610f\u7684\u6f0f\u6c34\u7126\u8651\u7531\u6b64\u5316\u89e3\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u9f99\u8109\u7684\u5b89\u88c5\u5de5\u827a\u6709\u4ec0\u4e48\u4e0d\u4e00\u6837\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u91c7\u7528\u94dc\u7ba1\u5145\u6c2e\u4fdd\u62a4\u710a\u63a5+\u5206\u6b67\u7ba1\u6c34\u5e73\u00b11\u00b0+\u4fdd\u6e29\u65e0\u6f0f\u5305\uff0c\u6c1f\u673a4.0MPa\u4fdd\u538b\uff08R410A\u6807\u51c6\uff09\uff0c36\u9879\u8282\u70b9\u9a8c\u6536\uff0c\u4e14\u6bcf\u6b65\u76d1\u7406\u5de1\u68c0\u62cd\u7167\u540c\u6b65\uff0c\u5de5\u827a\u770b\u5f97\u89c1\u3001\u4e0d\u5077\u5de5\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u4e24\u6c5f\u6620\u6708\u9644\u8fd1\u6709\u9f99\u8109\u95e8\u5e97\u5417\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u7c73\u8001\u5e08\u5bf9\u63a5\u95e8\u5e97\u4e3a\u5357\u5bcc\u68ee\u5e97\uff0c\u4f4d\u4e8e\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\uff08\u7535\u8bdd028-86131795\uff09\uff1b\u5317\u5bcc\u68ee\u5e97\u4f4d\u4e8e\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7\uff08\u7535\u8bdd028-65272586\uff09\u3002\"}\n    }\n  ]\n}\n<\/script>\n\n<!-- 3.BreadcrumbList \u9762\u5305\u5c51\u5bfc\u822a -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"BreadcrumbList\",\n  \"itemListElement\":[\n    {\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/longmai-nt.com\/\"},\n    {\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=2297\"},\n    {\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b\",\"item\":\"https:\/\/longmai-nt.com\/\"}\n  ]\n}\n<\/script>\n\n<!-- 4.LocalBusiness \u672c\u5730\u5546\u5bb6\u8f6c\u5316 -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"LocalBusiness\",\n  \"name\":\"\u9f99\u8109\u6696\u901a\",\n  \"description\":\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u5546\u5bb6\uff0c\u4e13\u6ce8\u5bb6\u7528\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u7cfb\u7edf\u3001\u65b0\u98ce\u7cfb\u7edf\u8bbe\u8ba1\u4e0e\u7cbe\u5de5\u65bd\u5de5\uff0c\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u53ca\u5468\u8fb9\u4e0a\u95e8\u52d8\u6d4b\u670d\u52a1\u3002\",\n  \"url\":\"https:\/\/longmai-nt.com\/\",\n  \"telephone\":\"028-86131795\",\n  \"openingHours\":[\"Mo-Su 09:00-18:00\"],\n  \"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5357\u5317\u53cc\u95e8\u5e97\",\"addressLocality\":\"\u6210\u90fd\u5e02\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"postalCode\":\"610000\"},\n  \"areaServed\":[\"\u6210\u534e\u533a\",\"\u6b66\u4faf\u533a\",\"\u9ad8\u65b0\u533a\",\"\u53cc\u6d41\u533a\",\"\u9f99\u6cc9\u9a7f\u533a\",\"\u90eb\u90fd\u533a\",\"\u9526\u6c5f\u533a\",\"\u4e24\u6c5f\u6620\u6708\",\"\u6210\u90fd\u5168\u57df\"],\n  \"sameAs\":[\"https:\/\/longmai-nt.com\/\"]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 22\u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6 \u00b7 \u771f [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-10680","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u4e00\u62d6\u56db\uff084 \u53f0\u5185\u673a\u603b\u51b7 16kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\uff0c\u8d85\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\uff0c22 \u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u7cbe\u5de5\u65bd\u5de5\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=10680\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u4e00\u62d6\u56db\uff084 \u53f0\u5185\u673a\u603b\u51b7 16kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\uff0c\u8d85\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\uff0c22 \u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u7cbe\u5de5\u65bd\u5de5\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=10680\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-23T05:47:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktpz.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680\",\"name\":\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/ljyy-mj-ktpz.jpg\",\"datePublished\":\"2026-08-18T10:10:49+00:00\",\"dateModified\":\"2026-10-23T05:47:45+00:00\",\"description\":\"\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u4e00\u62d6\u56db\uff084 \u53f0\u5185\u673a\u603b\u51b7 16kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\uff0c\u8d85\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\uff0c22 \u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u7cbe\u5de5\u65bd\u5de5\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/ljyy-mj-ktpz.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/ljyy-mj-ktpz.jpg\",\"width\":1440,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=10680#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u4e00\u62d6\u56db\uff084 \u53f0\u5185\u673a\u603b\u51b7 16kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\uff0c\u8d85\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\uff0c22 \u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u7cbe\u5de5\u65bd\u5de5\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=10680","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u4e00\u62d6\u56db\uff084 \u53f0\u5185\u673a\u603b\u51b7 16kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\uff0c\u8d85\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\uff0c22 \u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u7cbe\u5de5\u65bd\u5de5\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=10680","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-23T05:47:45+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktpz.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=10680","url":"https:\/\/longmai-nt.com\/?page_id=10680","name":"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=10680#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=10680#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktpz.jpg","datePublished":"2026-08-18T10:10:49+00:00","dateModified":"2026-10-23T05:47:45+00:00","description":"\u6210\u90fd\u53cc\u6d41\u4e24\u6c5f\u6620\u6708\u7c73\u8001\u5e08\u5973\u513f\u5a5a\u623f\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\uff0c\u9f99\u8109\u6696\u901a\u843d\u5730\u65e5\u7acb\u8212\u4eab RAS-125HRNAQ \u4e00\u62d6\u56db\uff084 \u53f0\u5185\u673a\u603b\u51b7 16kW\uff0c\u8fde\u63a5\u7387 1.28\uff09\uff0c\u8d85\u9759\u97f3\u3001\u81ea\u6e05\u6d01\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\u53cc\u9632\u6f0f\uff0c\u65e5\u7cfb\u54c1\u8d28\u653e\u5fc3\uff0c22 \u5e74\u65e5\u7acb\u6388\u6743\u5546\u5bb6\u7cbe\u5de5\u65bd\u5de5\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=10680#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=10680"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=10680#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktpz.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ljyy-mj-ktpz.jpg","width":1440,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=10680#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u53cc\u6d41\u533a\u4e24\u6c5f\u6620\u6708\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e00\u62d6\u56db\u6848\u4f8b"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10680","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10680"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10680\/revisions"}],"predecessor-version":[{"id":16362,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/10680\/revisions\/16362"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10680"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}