{"id":11380,"date":"2026-08-24T01:17:30","date_gmt":"2026-08-23T17:17:30","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=11380"},"modified":"2026-10-21T13:56:50","modified_gmt":"2026-10-21T05:56:50","slug":"%e6%b0%9f%e7%b3%bb%e7%bb%9f%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e3%80%81%e6%96%b0%e9%a3%8e%e9%9a%90%e8%94%bd%e5%b7%a5%e7%a8%8b%e9%aa%8c%e6%94%b6%e6%a0%87%e5%87%86%ef%bd%9c%e6%88%90%e9%83%bd%e6%97%a5","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=11380","title":{"rendered":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303"},"content":{"rendered":"\n\n<style>\n  :root{ --lm-red:#c0392b; --lm-ink:#222; --lm-line:#e6e6e6; --lm-soft:#fafafa; }\n  *{box-sizing:border-box;}\n  body{margin:0;background:#fff;color:var(--lm-ink);font-family:\"Microsoft YaHei\",\"PingFang SC\",sans-serif;font-size:16px;line-height:1.7;}\n  .wrap{max-width:900px;margin:0 auto;padding:28px 22px 60px;}\n  h1,.lm-title{font-size:25px;line-height:1.4;margin:0 0 6px;color:var(--lm-red);font-weight:700;}\n  h2{font-size:20px;margin:34px 0 10px;padding-bottom:6px;border-bottom:3px solid var(--lm-red);}\n  h3{font-size:17px;margin:20px 0 6px;color:#333;}\n  p{margin:8px 0;}\n  .lead{background:var(--lm-soft);border-left:4px solid var(--lm-red);padding:12px 16px;border-radius:0 8px 8px 0;margin:14px 0;}\n  img{width:100%;max-width:560px;display:block;margin:10px 0;border-radius:8px;border:1px solid var(--lm-line);}\n  .clause{border:1px solid var(--lm-line);border-radius:10px;padding:12px 16px;margin:12px 0;background:#fff;}\n  .clause b{color:var(--lm-red);}\n  .chk{color:#1e7e34;font-weight:700;}\n  table.fmt{border-collapse:collapse;width:100%;margin:12px 0;font-size:14.5px;}\n  table.fmt th,table.fmt td{border:1px solid #bbb;padding:8px 10px;vertical-align:top;text-align:left;}\n  table.fmt th{background:var(--lm-soft);white-space:nowrap;width:30%;}\n  .step-item{border:1px solid var(--lm-line);border-radius:10px;padding:14px 16px;margin:14px 0;background:#fff;}\n  .step-item h3{margin-top:0;}\n  .faq-item{border:1px solid var(--lm-line);border-radius:10px;padding:10px 16px;margin:10px 0;}\n  .faq-item h3{margin:0 0 4px;font-size:16px;}\n  .link-card{display:block;border:1px solid var(--lm-line);border-radius:10px;padding:10px 14px;margin:8px 0;text-decoration:none;color:var(--lm-ink);background:var(--lm-soft);}\n  .link-card:hover{border-color:var(--lm-red);}\n  .link-card .title{font-weight:700;color:var(--lm-red);}\n  .link-card .desc{display:block;font-size:13.5px;color:#666;margin-top:2px;}\n  .cta-box{background:#fff8f6;border:1px solid #f0c9bf;border-radius:12px;padding:18px 20px;margin:24px 0;}\n  .cta-box h3{margin:0 0 6px;color:var(--lm-red);}\n  .cta-box a{color:var(--lm-red);font-weight:700;text-decoration:none;}\n  .lm-store-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:18px 0;}\n  .lm-store{background:var(--lm-soft);border:1px solid var(--lm-line);border-radius:10px;padding:12px 14px;font-size:14px;}\n  .lm-store img{margin-bottom:8px;}\n  .lm-store .name{font-weight:700;color:var(--lm-red);}\n  ul.pit{background:#fff8f6;border:1px solid #f0c9bf;border-radius:10px;padding:12px 28px;margin:12px 0;}\n  @media(max-width:640px){.lm-store-grid{grid-template-columns:1fr;}}\n<\/style>\n\n<div class=\"wrap\">\n\n<p class=\"lm-title\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u6210\u90fd\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u89c4\u8303<\/p>\n<p class=\"lead\">\u672c\u9875\u6574\u7406\u9f99\u8109\u6696\u901a\u5728\u6210\u90fd\u672c\u5730\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u9879\u76ee\u7684<strong>\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6<\/strong>\uff0c\u4f9d\u636e\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303\u5236\u5b9a\u3002\u6bcf\u4e00\u6761\u90fd\u5bf9\u5e94\u660e\u786e\u7684\u5de5\u827a\u8981\u6c42\u4e0e\u53ef\u91cf\u5316\u9a8c\u6536\u70b9\uff0c\u5de5\u5730\u5b9e\u62cd\u5747\u6765\u81ea\u6210\u90fd\u672c\u5730\u5728\u5efa\u9879\u76ee\u3002\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u672c\u9875\u9010\u9879\u6838\u67e5\uff0c\u53ef\u5927\u5e45\u964d\u4f4e\u540e\u671f\u98ce\u91cf\u4e0d\u8db3\u3001\u6f0f\u6c34\u3001\u566a\u97f3\u7b49\u9690\u60a3\u3002<p>\u9a8c\u6536\u6807\u51c6\u4e0d\u662f\u73b0\u573a\u51ed\u7ecf\u9a8c\u5b9a\u7684\uff0c\u5b83\u6765\u81ea\u8bbe\u8ba1\u65b9\u6848\uff1a\u7ba1\u8def\u600e\u4e48\u8d70\u3001\u7ba1\u5f84\u591a\u7c97\u3001\u4fdd\u6e29\u591a\u539a\u3001\u6253\u538b\u5230\u51e0\u516c\u65a4\uff0c\u56fe\u7eb8\u4e0a\u5199\u6e05\u695a\u4e86\uff0c\u73b0\u573a\u624d\u9a8c\u5f97\u4e86\u3002\u8fd9\u7bc7\u628a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u7684\u9a8c\u6536\u6807\u51c6\u9010\u6761\u6446\u5f00\uff0c\u4f60\u53ef\u4ee5\u62ff\u7740\u5b83\u53bb\u5de5\u5730\u5bf9\u3002<\/p><\/p>\n\n<h2>\u4e00\u3001\u65bd\u5de5\u524d\u51c6\u5907\uff08\u6761\u6b3e1\u20132\uff09<\/h2>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg\" alt=\"\u6210\u90fd\u591a\u8054\u673a\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u5e73\u9762\u56fe\u00b7\u5de5\u5730\u5b9e\u62cd\" loading=\"lazy\">\n<div class=\"clause\">\n<p><b>\u6761\u6b3e1\uff1a\u65bd\u5de5\u56fe\u786e\u8ba4\u3002<\/b>\u6839\u636e\u8bbe\u8ba1\u56fe\u7eb8\u548c\u4e1a\u4e3b\u88c5\u9970\u8981\u6c42\uff0c\u5bf9\u65bd\u5de5\u73b0\u573a\u52d8\u67e5\u786e\u8ba4\uff0c\u786e\u5b9a\u5ba4\u5185\u5916\u673a\u5b89\u88c5\u4f4d\u7f6e\u3001\u7ba1\u9053\u8d70\u5411\u53ca\u6253\u5b54\u4f4d\u7f6e\u3001\u9001\u56de\u98ce\u65b9\u5f0f\u3001\u63a7\u5236\u5668\u4f4d\u7f6e\u7b49\u3002\u53d1\u73b0\u56fe\u7eb8\u4e0e\u73b0\u573a\u660e\u663e\u4e0d\u7b26\u5e94\u53ca\u65f6\u53d8\u66f4\u786e\u8ba4\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u73b0\u573a\u4ea4\u5e95\u6709\u56fe\u53ef\u4f9d\uff0c\u7a7a\u8c03\u7cfb\u7edf\u4e0e\u88c5\u4fee\u65b9\u6848\u534f\u8c03\u4e00\u81f4\uff0c\u907f\u514d\u540e\u7eed\u7ba1\u8def\u906e\u6321\u3001\u98ce\u53e3\u9519\u4f4d\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e2\uff1a\u5185\u3001\u5916\u5899\u6253\u5b54\u3002<\/b>\u6253\u5b54\u524d\u987b\u4e0e\u7528\u6237\u6c9f\u901a\u5e76\u5f81\u5f97\u7269\u4e1a\u540c\u610f\u3002\u5185\u5899\u6253\u5b54\u907f\u5f00\u623f\u6881\u94a2\u7b4b\uff08\u94a2\u7b4b\u591a\u5728\u4e24\u4fa7\uff09\uff1b\u5916\u5899\u6253\u5b54\u987b\u5411\u5916\u5899\u4fa7\u503e\u659c\uff0c\u9632\u6b62\u96e8\u6c34\u5012\u704c\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u5b54\u4f4d\u7ecf\u7528\u6237\u4e0e\u7269\u4e1a\u786e\u8ba4\uff0c\u907f\u5f00\u627f\u91cd\u7ed3\u6784\u4e0e\u7535\u7ebf\uff0c\u5916\u5899\u5b54\u5916\u4f4e\u5185\u9ad8\u3002<\/p>\n<\/div>\n\n<h2>\u4e8c\u3001\u5ba4\u5185\u673a\u5b89\u88c5\uff08\u6761\u6b3e3\u20136\uff09<\/h2>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u5c0a\u777f\u5185\u673a\u6807\u51c6\u5b89\u88c5\u5de5\u5730\u5b9e\u62cd\" loading=\"lazy\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-gdsb.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u5b9e\u62cd\" loading=\"lazy\">\n<div class=\"clause\">\n<p><b>\u6761\u6b3e3\uff1a\u5ba4\u5185\u673a\u5b9a\u4f4d\u3002<\/b>\u5ba4\u5185\u673a\u5de6\u53f3\u7559\u7a7a\u95f4\uff0c\u540e\u4fa7\u79bb\u5899\u4e0d\u5c0f\u4e8e<b>100mm<\/b>\uff0c\u9876\u90e8\u4e0e\u5929\u82b1\u677f\u95f4\u8ddd\u4e0d\u5c0f\u4e8e<b>10mm<\/b>\uff1b\u98ce\u7ba1\u673a\u91c7\u7528\u540e\u56de\u98ce\u964d\u4f4e\u566a\u97f3\uff0c\u540e\u4fa7\u8fdb\u98ce\u987b\u7559\u5145\u8db3\u8fdb\u98ce\u7a7a\u95f4\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u79bb\u5899\u2265100mm\u3001\u9876\u8ddd\u226510mm\uff0c\u56de\u98ce\u7a7a\u95f4\u5145\u8db3\uff0c\u907f\u514d\u98ce\u91cf\u4e0d\u8db3\u4e0e\u540a\u9876\u5171\u632f\u5f02\u54cd\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e4\uff1a\u5ba4\u5185\u673a\u56fa\u5b9a\u3002<\/b>\u7528\u03a610mm\u81a8\u80c0\u87ba\u6813\u6216\u03a610mm\u9540\u950c\u4e1d\u6746\u540a\u88c5\uff0c\u8c03\u6c34\u5e73\uff0c\u53cc\u87ba\u6bcd\u53cc\u51cf\u9707\u57ab\u56fa\u5b9a\uff0c\u5fc5\u8981\u65f6\u52a0\u5e95\u87ba\u6bcd\u9632\u677e\uff0c\u540a\u6746\u4e0d\u6b6a\u659c\u3001\u4e0d\u78b0\u673a\u7ec4\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u53cc\u87ba\u6bcd+\u53cc\u51cf\u9707\u57ab\uff0c\u6c34\u5e73\u5ea6\u5408\u683c\uff0c\u65e0\u6643\u52a8\u5f02\u54cd\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e5\uff1a\u659c\u6491\u52a0\u5f3a\u56fa\u5b9a\u3002<\/b>\u540a\u6746\u957f\u5ea6\u8d85\u8fc7<b>1.5m<\/b>\u65f6\uff0c\u5bf9\u89d2\u52a0\u659c\u6491\u52a0\u5f3a\u56fa\u5b9a\uff0c\u9632\u6b62\u673a\u7ec4\u8fd0\u884c\u632f\u52a8\u6446\u52a8\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u957f\u540a\u6746\u6709\u659c\u6491\uff0c\u7ed3\u6784\u7a33\u56fa\u65e0\u5b89\u5168\u9690\u60a3\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e6\uff1a\u5ba4\u5185\u673a\u4fdd\u62a4\u3002<\/b>\u51fa\u98ce\u53e3\u3001\u56de\u98ce\u53e3\u7528\u5851\u6599\u888b\u6216\u65e5\u7acb\u5c01\u53e3\u6761\u5bc6\u5c01\u9632\u5c18\uff0c\u9632\u6b62\u88c5\u4fee\u7070\u5c18\u8fdb\u5165\u6362\u70ed\u5668\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u5185\u673a\u98ce\u53e3\u5168\u7a0b\u5bc6\u5c01\uff0c\u65e0\u79ef\u5c18\u3002<\/p>\n<\/div>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-fdaz.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u5185\u673a\u4e0b\u51fa\u4e0b\u56de\u98ce\u9053\u8bbe\u8ba1\u5b9e\u62cd\" loading=\"lazy\">\n\n<h2>\u4e09\u3001\u5ba4\u5916\u673a\u5b89\u88c5\uff08\u6761\u6b3e7\u201312\uff09<\/h2>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-xz2.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5ba4\u5916\u673a\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\">\n<div class=\"clause\">\n<p><b>\u6761\u6b3e7\uff1a\u5ba4\u5916\u673a\u4fdd\u62a4\u3002<\/b>\u5b89\u88c5\u5230\u4f4d\u524d\u4e0d\u62c6\u5916\u5305\u88c5\uff0c\u505a\u597d\u9632\u62a4\uff0c\u9632\u6b62\u673a\u68b0\u635f\u4f24\u6216\u5f02\u7269\u8fdb\u5165\u3002<\/p>\n<p><b>\u6761\u6b3e8\uff1a\u5ba4\u5916\u673a\u5b9a\u4f4d\u3002<\/b>\u6362\u70ed\u5668\u8fdb\u98ce\u4fa7\u79bb\u5899\u4e0d\u5c0f\u4e8e<b>200mm<\/b>\uff0c\u8fdc\u79bb\u5367\u5ba4\u51cf\u5c11\u566a\u97f3\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u79bb\u5899\u2265200mm \u4fdd\u969c\u6563\u70ed\uff0c\u4f4e\u9891\u566a\u97f3\u4e0d\u5f71\u54cd\u5c45\u4f4f\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e9\uff1a\u767e\u53f6\u7a97\u3002<\/b>\u5916\u673a\u51fa\u98ce\u4fa7\u767e\u53f6\u987b\u901a\u98ce\u987a\u7545\u3001\u963b\u529b\u5c0f\u7684\u76f4\u767e\u53f6\uff0c\u503e\u89d2\u226410\u00b0\uff0c\u95f4\u8ddd\u226580mm\uff0c\u6c34\u5e73\u51c0\u9762\u79ef\u226580%\uff0c\u5916\u673a\u9760\u8fd1\u767e\u53f6\u4fa7\u9632\u56de\u98ce\u77ed\u8def\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u767e\u53f6\u901a\u98ce\u9762\u79ef\u8fbe\u6807\uff0c\u65e0\u70ed\u98ce\u56de\u6d41\uff0c\u538b\u7f29\u673a\u4e0d\u957f\u671f\u9ad8\u6e29\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e10\uff1a\u5bfc\u98ce\u7f69\uff08\u9009\u914d\uff09\u3002<\/b>\u5fc5\u8981\u65f6\u52a0\u88c5\u5bfc\u98ce\u7f69\uff0c\u6539\u5584\u51fa\u98ce\u65b9\u5411\uff0c\u907f\u514d\u70ed\u98ce\u56de\u6d41\u6563\u70ed\u6076\u5316\u3002<\/p>\n<p><b>\u6761\u6b3e11\uff1a\u5ba4\u5916\u673a\u56fa\u5b9a\u3002<\/b>\u6c34\u5e73\u5b89\u88c5\uff0c\u57fa\u7840\/\u652f\u67b6\u627f\u91cd\u8db3\u591f\uff0c\u5e95\u5ea7\u94fa\u6a61\u80f6\u51cf\u9707\u57ab\uff0c\u87ba\u6813\u56fa\u5b9a\u7262\u56fa\uff0c\u8003\u8651\u6392\u6c34\u9632\u6ef4\u6c34\u3002<\/p>\n<p><b>\u6761\u6b3e12\uff1a\u5916\u673a\u63a5\u6c34\u76d8\uff08\u9009\u914d\uff09\u3002<\/b>\u5b89\u88c5\u5230\u4f4d\u3001\u56fa\u5b9a\u7262\u56fa\u3001\u6392\u6c34\u65b9\u5411\u6b63\u786e\uff0c\u6536\u96c6\u5316\u971c\u6c34\/\u96e8\u6c34\u9632\u6e17\u6f0f\u3002<\/p>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-04.jpeg\" alt=\"\u6210\u90fd\u65e5\u7acb\u53cc\u98ce\u6247\u5ba4\u5916\u673a\u5b9e\u62cd\" loading=\"lazy\">\n<\/div>\n\n<h2>\u56db\u3001\u51b7\u5a92\u914d\u7ba1\u4e0e\u710a\u63a5\uff08\u6761\u6b3e13\u201318\uff09<\/h2>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-tg.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\">\n<div class=\"clause\">\n<p><b>\u6761\u6b3e13\uff1a\u51b7\u5a92\u914d\u7ba1\u4e09\u539f\u5219\u3002<\/b>\u5e72\u71e5\uff08\u65e0\u6c34\u5206\uff09\u3001\u6e05\u6d01\uff08\u65e0\u6742\u8d28\uff09\u3001\u6c14\u5bc6\uff08\u65e0\u6cc4\u6f0f\uff09\u2014\u2014\u6c34\u5206\u3001\u6742\u8d28\u3001\u6cc4\u6f0f\u662f\u538b\u7f29\u673a\u635f\u574f\u7684\u4e09\u5927\u4e3b\u56e0\u3002<\/p>\n<p><b>\u6761\u6b3e14\uff1a\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u3002<\/b>\u6c2e\u6c14\u6d41\u91cf\u2265<b>0.05m\u00b3\/h<\/b>\u3001\u538b\u529b<b>0.02\u20130.05MPa<\/b>\uff0c\u94dc\u7ba1\u5185\u7a7a\u6c14\u7f6e\u6362\u5b8c\u5168\u540e\u65bd\u710a\uff1b\u786c\u948e\u710a\u3001\u542b\u94f6\u91cf\u22652%\u710a\u6761\u3001\u4e2d\u6027\u7130 700\u2013845\u2103\u3001\u7981\u6b62\u5012\u710a\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u6c2e\u6c14\u4fdd\u62a4\u710a\uff0c\u5185\u58c1\u65e0\u6c27\u5316\u76ae\uff0c\u907f\u514d\u5835\u585e\u7535\u5b50\u81a8\u80c0\u9600\u3001\u635f\u574f\u538b\u7f29\u673a\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e15\uff1a\u5206\u6b67\u7ba1\u5b89\u88c5\u3002<\/b>\u5206\u6b67\u7ba1\u4e09\u5206\u652f\u540c\u4e00\u6c34\u5e73\u9762\uff08\u6c34\u5e73\u88c5\uff09\u6216\u4e0d\u504f\u659c\uff08\u5782\u76f4\u88c5\uff09\uff1b\u76f8\u90bb\u5206\u6b67\u7ba1\u76f4\u7ba1\u6bb5\u2265<b>500mm<\/b>\uff0c\u5165\u53e3\u4fa7\u2265500mm\uff0c\u907f\u514d\u51b7\u5a92\u504f\u6d41\u4e0e\u6d41\u52a8\u566a\u97f3\u3002<\/p>\n<p><b>\u6761\u6b3e16\uff1a\u94dc\u7ba1\u6a2a\u7ba1\u56fa\u5b9a\u4e0e\u4fdd\u62a4\u3002<\/b>\u6c14\u7ba1\u3001\u6db2\u7ba1\u3001\u51b7\u51dd\u6c34\u7ba1\u3001\u7ebf\u7ba1\u5206\u5c42\u72ec\u7acb\u5b89\u88c5\uff0c\u9540\u950c\u652f\u67b6+\u4e0d\u9508\u94a2U\u578b\u5361\u7801\u56fa\u5b9a\uff0c\u4fdd\u6e29\u5c42\u5916\u52a0 PVC \u5957\u7ba1\u4fdd\u62a4\uff0c\u8d34\u6807\u8bc6\u6807\u8d34\uff0c\u4e0d\u5141\u8bb8\u591a\u7ba1\u7ed1\u5728\u4e00\u8d77\u56fa\u5b9a\u3002<\/p>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd2.jpg\" alt=\"\u6210\u90fd\u65e5\u7acb\u5185\u673a\u6807\u51c6\u8d70\u7ba1\u542b\u5206\u6b67\u7ba1\u5b9e\u62cd\" loading=\"lazy\">\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e17\uff1a\u94dc\u7ba1\u7a7f\u5899\u56fa\u5b9a\u3002<\/b>\u7a7f\u5899\/\u7a7f\u697c\u677f\u4e24\u7aef\u8ddd\u5899 400\u2013500mm \u56fa\u5b9a\uff0c\u7f1d\u9699\u7528\u963b\u71c3\u6750\u6599\u586b\u6ee1\uff0c\u9632\u5c0f\u52a8\u7269\u8fdb\u5165\u3002<\/p>\n<p><b>\u6761\u6b3e18\uff1a\u6237\u5916\u7ba1\u8def\u4fdd\u62a4\uff08\u9009\u914d\uff09\u3002<\/b>\u6237\u5916\u7ba1\u8def\u52a0 ABS \u6216\u9540\u950c\u94a2\u677f\u4fdd\u62a4\u5957\uff0c\u9632\u6c34\u9632\u6652\u9632\u8001\u5316\uff0c\u51cf\u5c11\u51b7\u70ed\u91cf\u635f\u5931\u3002<\/p>\n<\/div>\n<h3>\u51b7\u5a92\u7ba1\u6700\u5c0f\u58c1\u539a\u6838\u9a8c\uff08\u9a8c\u6536\u786c\u6307\u6807\uff09<\/h3>\n<p>\u94dc\u7ba1\u53ea\u6807\u7ba1\u5f84\u3001\u4e0d\u6807\u58c1\u539a\u7684\uff0c\u591a\u4e3a\u975e\u6807\u7ba1\u3002\u9a8c\u6536\u65f6\u9010\u4e00\u6838\u5bf9\u94ed\u724c\u4e0a\u7684\u7ba1\u5f84\u4e0e\u58c1\u539a\uff0c\u4e24\u8005\u9f50\u5168\u624d\u7b97\u5408\u683c\u2014\u2014\u8fd9\u662f\u9632\"\u7528\u8584\u7ba1\u5192\u5145\u6807\u51c6\u7ba1\"\u7684\u786c\u6307\u6807\u3002<\/p>\n<table>\n<thead><tr><th>\u51b7\u5a92\u7ba1\u5916\u5f84<\/th><th>\u6700\u5c0f\u58c1\u539a<\/th><th>\u9a8c\u6536\u52a8\u4f5c<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u03c66 \u2013 \u03c616<\/td><td>\u2265 0.8 mm<\/td><td>\u6838\u5bf9\u94ed\u724c\uff0c\u91cf\u58c1\u539a<\/td><\/tr>\n<tr><td>\u03c616 \u2013 \u03c629<\/td><td>\u2265 1.0 mm<\/td><td>\u6838\u5bf9\u94ed\u724c\uff0c\u91cf\u58c1\u539a<\/td><\/tr>\n<tr><td>\u03c629 \u2013 \u03c635<\/td><td>\u2265 1.2 mm<\/td><td>\u6838\u5bf9\u94ed\u724c\uff0c\u91cf\u58c1\u539a<\/td><\/tr>\n<tr><td>\u03c635 \u2013 \u03c651<\/td><td>\u2265 1.5 mm<\/td><td>\u6838\u5bf9\u94ed\u724c\uff0c\u91cf\u58c1\u539a<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p><b>\u9a8c\u6536\u5224\u5b9a<\/b>\uff1a\u51e1\u53ea\u6807\u7ba1\u5f84\u4e0d\u6807\u58c1\u539a\u7684\u975e\u6807\u94dc\u7ba1\uff0c\u4e00\u5f8b\u5224\u5b9a\u4e0d\u5408\u683c\uff0c\u4e0d\u4e88\u9a8c\u6536\u3002\u58c1\u539a\u4e0d\u8fbe\u6807\u5728\u6253\u538b\u65f6\u4e0d\u6f0f\u3001\u88c5\u5b8c\u624d\u6f0f\uff0c\u662f\u540e\u671f\u6f0f\u6c34\u6f0f\u6c1f\u7684\u5e38\u89c1\u6839\u56e0\u3002<\/p>\n\n<h3>\u62bd\u771f\u7a7a\u7684\u5177\u4f53\u89c4\u8303\uff08\u65f6\u9650\u4e0e\u8bbe\u5907\uff09<\/h3>\n<p>\u771f\u7a7a\u5ea6\u5230 -0.1MPa \u53ea\u662f\u53ca\u683c\u7ebf\uff0c\u8fd8\u8981\u770b\"\u4fdd\u6301\u591a\u4e45\"\u548c\"\u7528\u4ec0\u4e48\u6cf5\"\uff0c\u8fd9\u4e24\u70b9\u51b3\u5b9a\u7cfb\u7edf\u91cc\u6709\u6ca1\u6709\u6b8b\u7559\u6c34\u5206\u3002<\/p>\n<ul>\n<li><b>\u4fdd\u771f\u7a7a\u65f6\u95f4<\/b>\uff1a\u771f\u7a7a\u5ea6\u8fbe\u5230 -0.1MPa\uff08-755mmHg\uff09\u540e\uff0c\u4fdd\u771f\u7a7a \u2265 2 \u5c0f\u65f6\uff0c\u538b\u529b\u65e0\u56de\u5347\u4e3a\u5408\u683c\u3002<\/li>\n<li><b>\u771f\u7a7a\u6cf5\u89c4\u683c<\/b>\uff1a\u62bd\u901f \u2265 2 L\/s \u7684\u771f\u7a7a\u6cf5\uff0c\u4e14\u5fc5\u987b\u5e26\u9006\u6b62\u9600\u2014\u2014\u9632\u6b62\u6cf5\u505c\u6b62\u77ac\u95f4\u7a7a\u6c14\u5012\u6d41\u56de\u7cfb\u7edf\u3002<\/li>\n<li><b>\u62bd\u7a7a\u65b9\u5f0f<\/b>\uff1a\u6c14\u6db2\u4fa7\u540c\u65f6\u62bd\u771f\u7a7a\uff0c\u4e0d\u80fd\u53ea\u62bd\u4e00\u4fa7\u3002<\/li>\n<\/ul>\n\n<h3>\u5206\u6b67\u7ba1\u5b89\u88c5\u65b9\u5411\u7ec6\u5219<\/h3>\n<p>\u5206\u6b67\u7ba1\u88c5\u6b6a\u4e86\uff0c\u51b7\u5a92\u5206\u6d41\u4e0d\u5747\uff0c\u8868\u73b0\u4e3a\u67d0\u4e9b\u623f\u95f4\u5ffd\u51b7\u5ffd\u70ed\u3001\u566a\u97f3\u5927\u3002\u4e09\u6761\u786c\u89c4\u77e9\uff1a<\/p>\n<table>\n<thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u8303\u8981\u6c42<\/th><th>\u4e0d\u5408\u683c\u7684\u540e\u679c<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u6c34\u5e73\u5b89\u88c5<\/td><td>\u987b\u4fdd\u6301\u540c\u4e00\u6c34\u5e73\u9762\uff0c\u4e0d\u5f97\u503e\u659c<\/td><td>\u51b7\u5a92\u504f\u6d41\uff0c\u90e8\u5206\u623f\u95f4\u4e0d\u51b7<\/td><\/tr>\n<tr><td>\u5782\u76f4\u5b89\u88c5<\/td><td>\u4ece\u4e0a\u5230\u4e0b\u6309\u6b63\u786e\u8d70\u5411\uff0c\u4e0d\u504f\u659c<\/td><td>\u56de\u6cb9\u4e0d\u7545\uff0c\u538b\u7f29\u673a\u53d7\u635f<\/td><\/tr>\n<tr><td>\u51fa\u53e3\u76f4\u7ba1\u6bb5<\/td><td>\u51fa\u5206\u652f\u53e3\u540e \u2265 0.5 m \u5185\u4e0d\u5f97\u6709\u5f2f\u5934<\/td><td>\u5206\u6d41\u4e0d\u5747\uff0c\u4ea7\u751f\u6d41\u52a8\u566a\u97f3<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h3>\u5236\u51b7\u5242\u8ffd\u52a0\u91cf\u7684\u8ba1\u7b97\u89c4\u5219<\/h3>\n<p>\u8ffd\u52a0\u91cf\u5fc5\u987b\u6309\u65e5\u7acb\u9009\u578b\u8d44\u6599\u8ba1\u7b97\uff0c\u4e0d\u80fd\u51ed\u7ecf\u9a8c\u4f30\u3002\u4f30\u5c11\u4e86\u5236\u51b7\u6548\u679c\u5dee\u3001\u8017\u7535\u9ad8\uff0c\u4f30\u591a\u4e86\u538b\u7f29\u673a\u8d1f\u8377\u8fc7\u5927\u3002<\/p>\n<p><b>\u8ffd\u52a0\u91cf \uff1d \u6db2\u7ba1\u957f\u5ea6\u5bf9\u5e94\u51b7\u5a92\u91cf \uff0b \u5206\u6b67\u7ba1\u51b7\u5a92\u91cf \uff0b \u5ba4\u5185\u673a\u5bb9\u91cf\u5bf9\u5e94\u91cf<\/b>\uff0c\u4e09\u9879\u5206\u522b\u67e5\u65e5\u7acb\u9009\u578b\u8868\u53d6\u503c\u540e\u76f8\u52a0\uff0c\u79f0\u91cd\u5145\u6ce8\uff0c\u8bef\u5dee\u63a7\u5236\u5728 \u00b15 g \u5185\uff0c\u5e76\u586b\u5165\u65bd\u5de5\u8bb0\u5f55\u3002<\/p>\n<p>\u9a8c\u6536\u52a8\u4f5c\uff1a\u6838\u5bf9\u65bd\u5de5\u8bb0\u5f55\u8868\u4e0a\u7684\"\u6db2\u7ba1\u5b9e\u9645\u957f\u5ea6\"\u4e0e\"\u8ffd\u52a0\u91cf\"\uff0c\u4e24\u9879\u5bf9\u5f97\u4e0a\u624d\u7b97\u5408\u683c\u3002<\/p>\n\n<h2>\u4e94\u3001\u7ba1\u8def\u7cfb\u7edf\uff08\u6761\u6b3e19\u201328\uff09<\/h2>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-04.jpeg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u5e03\u5c40\u5de5\u5730\u5b9e\u62cd\" loading=\"lazy\">\n<div class=\"clause\">\n<p><b>\u6761\u6b3e19\uff1a\u652f\u540a\u67b6\u95f4\u8ddd\u3002<\/b>\u4e24\u4e2a\u652f\u540a\u67b6\u95f4\u8ddd <b>0.8\u20131.0m<\/b>\uff0c\u5206\u5e03\u5747\u5300\u7f8e\u89c2\u3002<\/p>\n<p><b>\u6761\u6b3e20\uff1a\u5ba4\u5185\u7ba1\u8def\u6574\u4f53\u5c55\u793a\u3002<\/b>\u7ba1\u8def\u8c03\u76f4\u3001\u8d70\u5411\u6e05\u6670\u3001\u73b0\u573a\u6574\u6d01\uff0c\u6a2a\u5e73\u7ad6\u76f4\u4fbf\u4e8e\u68c0\u4fee\u3002<\/p>\n<p><b>\u6761\u6b3e21\uff1a\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u3002<\/b>\u5761\u5ea6\u2265<b>5\u2030<\/b>\uff0c\u5e26\u63d0\u5347\u6cf5\u7684\u5ba4\u5185\u673a\u6392\u6c34\u51fa\u53e3\u5761\u5ea6\u22651%\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u5761\u5ea6\u8db3\u591f\uff0c\u91cd\u529b\u6392\u6c34\u987a\u7545\uff0c\u4e0d\u5835\u4e0d\u5012\u6d41\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e22\uff1a\u5e26\u6cf5\u5ba4\u5185\u673a\u8fd4\u6c34\u5f2f\u3002<\/b>\u63d0\u5347\u9ad8\u5ea6\u4e00\u822c 100\u2013300mm\u3001\u6700\u5927\u4e0d\u8d85\u8fc7 500mm\uff1b\u6392\u6c34\u53e3\u81f3\u8fd4\u6c34\u5f2f\u6700\u9ad8\u70b9\u603b\u957f\u2264\u6cf5\u626c\u7a0b <b>1.1m<\/b>\u3002<\/p>\n<p><b>\u6761\u6b3e23\uff1a\u5ba4\u5185\u673a\u6392\u6c34\u53e3\u8fde\u63a5\u3002<\/b>\u968f\u673a\u6392\u6c34\u8f6f\u7ba1+\u5361\u7b8d\u56fa\u5b9a\uff0c\u4e0d\u5f2f\u66f2\u3001\u4e0d\u4f5c\u4e3a\u5f2f\u5934\u7528\u3002<\/p>\n<p><b>\u6761\u6b3e24\uff1a\u51b7\u51dd\u6c34\u7ba1\u56fa\u5b9a\u3002<\/b>\u6a2a\u7ba1 0.5\u20131.0m \u4e00\u5361\u3001\u7acb\u7ba1 1.5\u20132m \u4e00\u5361\u3001\u6bcf\u7acb\u7ba1\u22652 \u4e2a\uff0c\u62d0\u89d2\u4e24\u7aef\u56fa\u5b9a\u3002<\/p>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u5b9e\u62cd\" loading=\"lazy\">\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e25\uff1a\u51b7\u51dd\u6c34\u7ba1\u901a\u6c14\u5b54\u3002<\/b>\u9ad8\u70b9\u8bbe\u901a\u6c14\u5b54\u3001\u4e0a\u7aef\u52a0\u5f2f\u5934\u9632\u6742\u7269\uff1b\u5168\u90e8\u5b8c\u6210\u540e\u505a\u6392\u6c34\u5b9e\u9a8c\uff0c\u6392\u6c34\u53e3\u4e0d\u76f4\u6392\u6c61\u6c34\u7ba1\u3002<\/p>\n<p><b>\u6761\u6b3e26\uff1a\u5408\u6d41\u53ca\u900f\u6c14\u7ba1\u3002<\/b>\u5ba4\u5185\u673a\u6392\u6c34\u7ba1\u5c3d\u91cf\u4ece\u4e0a\u5411\u6c34\u5e73\u4e3b\u7ba1\u5408\u6d41\uff1b\u6a2a\u7ba1\u8bbe\u900f\u6c14\u7ba1\u3001\u5165\u7acb\u7ba1\u65f6\u7acb\u7ba1\u5411\u4e0a\u900f\u6c14\uff0c\u900f\u6c14\u7ba1\u4e0a\u7aef\u52a0\u5f2f\u5934\u3002<\/p>\n<p><b>\u6761\u6b3e27\uff1a\u4fdd\u6e29\u7ba1\u89c4\u683c\u4e0e\u8fde\u63a5\u3002<\/b>\u4fdd\u6e29\u58c1\u539a\uff1a\u94dc\u7ba1\u2265\u03a615.88mm \u7528\u226519mm\u3001\u2264\u03a612.7mm \u7528\u226513mm\uff0c\u51b7\u51dd\u6c34\u7ba1\u22659mm\uff08\u6f6e\u6e7f\u5730\u533a\u226513mm\uff09\uff1b\u63a5\u7f1d\u7528\u6a61\u5851\u4e13\u7528\u80f6+50mm \u80f6\u5e26\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u4fdd\u6e29\u4e25\u5bc6\u65e0\u5f00\u88c2\uff0c\u4ece\u6e90\u5934\u9632\u540a\u9876\u53d1\u9709\u3001\u5899\u9762\u6e17\u6c34\u3002<\/p>\n<\/div>\n\n<h2>\u516d\u3001\u7535\u6c14\u4e0e\u63a7\u5236\u5668\uff08\u6761\u6b3e28\u201330\uff09<\/h2>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e28\uff1a\u7535\u6e90\u7ebf\u3001\u901a\u8baf\u7ebf\u6577\u8bbe\u3002<\/b>\u7535\u6e90\u7ebf\u3001\u63a7\u5236\u7ebf\u5355\u72ec\u7a7f\u7ebf\u7ba1\u4fdd\u62a4\uff0c\u7ebf\u7ba1\u95f4\u7528\u63a5\u7ebf\u76d2\u8fde\u63a5\uff0c\u9632\u9f20\u54ac\u4e0e\u540e\u671f\u635f\u4f24\u77ed\u8def\u3002<\/p>\n<p><b>\u6761\u6b3e29\uff1a\u7ebf\u63a7\u5668\u5b89\u88c5\u524d\u4fdd\u62a4\u3002<\/b>\u901a\u4fe1\u7ebf\u7aef\u5b50\u7edd\u7f18\u5904\u7406\uff0c\u63a8\u8350\u88c5\u76d2\u76d6\u9632\u5c18\u9632\u6f6e\u9632\u77ed\u8def\u3002<\/p>\n<p><b>\u6761\u6b3e30\uff1a\u63a7\u5236\u5668\u5b89\u88c5\u3002<\/b>\u7262\u56fa\u3001\u6574\u9f50\uff0c\u4e0d\u6b6a\u659c\u3002<\/p>\n<\/div>\n\n<h2>\u4e03\u3001\u6c14\u5bc6\u6027\u8bd5\u9a8c\u4e0e\u5236\u51b7\u5242\u8ffd\u52a0\uff08\u6761\u6b3e31\u201332\uff09<\/h2>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-bzd.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u6c2e\u6c14\u4fdd\u538b\u5b9e\u62cd\" loading=\"lazy\">\n<div class=\"clause\">\n<p><b>\u6761\u6b3e31\uff1a\u6c14\u5bc6\u6027\u8bd5\u9a8c\u3002<\/b>\u5e72\u71e5\u6c2e\u6c14\u4ecb\u8d28\uff0c\u622a\u6b62\u9600\u5173\u4e25\u540e\u4ece\u6c14\u7ba1\u3001\u6db2\u7ba1\u5145\u6c2e\uff0c\u7f13\u6162\u52a0\u538b\u81f3 <b>4.15MPa<\/b>\uff08R410A \u7cfb\u7edf\uff09\uff0c\u4fdd\u538b <b>24h<\/b>\uff0c\u538b\u529b\u4e0d\u964d\u4e3a\u5408\u683c\uff1b\u6e29\u5ea6\u6bcf\u53d8 1\u2103 \u538b\u529b\u53d8\u7ea6 0.01MPa \u9700\u4fee\u6b63\u3002\u5408\u683c\u540e\u964d\u81f3 1.5MPa \u4fdd\u538b\uff0c\u907f\u514d\u957f\u671f\u9ad8\u538b\u4f24\u7ba1\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>4.15MPa \u4fdd\u538b 24h \u5408\u683c\uff0c\u6240\u6709\u63a5\u5934\u65e0\u6cc4\u6f0f\uff0c\u65b9\u53ef\u653e\u5fc3\u5c01\u677f\u2014\u2014\u8fd9\u662f\u9690\u853d\u5de5\u7a0b\u6700\u5173\u952e\u8282\u70b9\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e32\uff1a\u5236\u51b7\u5242\u8ffd\u52a0\u3002<\/b>\u6309\u968f\u673a\u8d44\u6599\u8ba1\u7b97\u5e76\u8bb0\u5f55\u8ffd\u52a0\u91cf\uff0c\u79f0\u91cd\u5145\u6ce8\uff0c\u8bef\u5dee\u00b15g \u5185\uff0c\u4fdd\u8bc1\u7cfb\u7edf\u6548\u679c\u4e0e\u80fd\u8017\u6b63\u5e38\u3002<\/p>\n<\/div>\n\n<h2>\u516b\u3001\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/h2>\n<p>\u6240\u6709\u5230\u573a\u8bbe\u5907\u6750\u6599\u4e0e\u5408\u540c\u914d\u7f6e\u6e05\u5355\u9010\u4e00\u6838\u5bf9\uff0c\u54c1\u724c\u3001\u578b\u53f7\u3001\u89c4\u683c\u4e00\u81f4\u65b9\u53ef\u7b7e\u6536\u3002\u6bcf\u7c7b\u6750\u6599\u5bf9\u5e94\u5b9e\u62cd\u5982\u4e0b\uff0c\u5ba2\u6237\u53ef\u9010\u9879\u6838\u5bf9\uff1a<\/p>\n<table class=\"fmt\">\n<tbody>\n<tr><th>\u6750\u6599\u540d\u79f0<\/th><th>\u8fdb\u573a\u5b9e\u62cd<\/th><th>\u9a8c\u6536\u91cd\u70b9<\/th><\/tr>\n<tr><td><b>\u5185\u673a<\/b><br>\u5916\u5305\u88c5\u5b8c\u597d\u3001\u7801\u653e\u6574\u9f50\u3001\u53ef\u89c1\u578b\u53f7\u6807\u8bc6<\/td><td><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-xz.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5185\u673a\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\" style=\"max-width:240px\"><\/td><td>\u5305\u88c5\u5b8c\u597d\u3001\u578b\u53f7\u6807\u8bc6\u6e05\u6670<\/td><\/tr>\n<tr><td><b>\u5916\u673a\uff08\u5982\u6709\u5230\u573a\uff09<\/b><br>\u5916\u5305\u88c5\u5b8c\u597d\u3001\u53ef\u89c1\u578b\u53f7\u6807\u8bc6<\/td><td><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-xz2.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5916\u673a\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\" style=\"max-width:240px\"><\/td><td>\u578b\u53f7\u4e0e\u5408\u540c\u4e00\u81f4<\/td><\/tr>\n<tr><td><b>\u94dc\u7ba1<\/b><br>\u4e0d\u540c\u89c4\u683c\u58c1\u539a\u6807\u8bc6 0.8mm \/ 1.0mm<\/td><td><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-tg.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u94dc\u7ba1\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\" style=\"max-width:240px\"><\/td><td>\u58c1\u539a\u6807\u8bc6\u6e05\u6670<\/td><\/tr>\n<tr><td><b>\u5206\u6b67\u7ba1 \/ \u51b7\u51dd\u6c34\u7ba1 \/ \u4fdd\u6e29\u68c9 \/ \u7ebf\u7ba1 \/ \u7535\u7f06 \/ \u8f85\u6750<\/b><\/td><td><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/wkhy-lls-bqtg.jpg\" alt=\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\" loading=\"lazy\" style=\"max-width:240px\"><\/td><td>\u54c1\u724c\u3001\u89c4\u683c\u4e0e\u5408\u540c\u4e00\u81f4<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h2>\u4e5d\u3001\u6253\u5b54\u4e0e\u5899\u9762\u5f00\u69fd\uff08\u6761\u6b3e33\u201334\uff09<\/h2>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e33\uff1a\u5185\u5916\u5899\u6253\u5b54\u3002<\/b>\u6253\u5b54\u524d\u4e0e\u4e1a\u4e3b\u53ca\u7269\u4e1a\u6c9f\u901a\u786e\u8ba4\uff0c\u907f\u5f00\u6c34\u7535\u6697\u7ba1\uff0c\u4e0d\u7834\u574f\u627f\u91cd\u7ed3\u6784\u3002\u6881\u4e0a\u5f00\u5b54\u5b9c\u907f\u5f00\u6881\u7aef\u9760\u8fd1\u6881\u67f1\u8282\u70b9\u5904\u3001\u6881\u5e95\u5411\u4e0a 5~10cm\uff08\u4e3b\u7b4b\u6240\u5728\u533a\u57df\uff09\u3001\u4e3b\u6b21\u6881\u4ea4\u63a5\u5904\uff0c\u63a8\u8350\u5728\u6881\u8de8\u4e2d 1\/3 \u533a\u6bb5\u3001\u6881\u9ad8\u4e2d\u90e8\u5f00\u5b54\u3002\u73b0\u573a\u6761\u4ef6\u53d7\u9650\u65f6\uff0c\u6309\u5c3d\u91cf\u4f18\u5316\u7684\u4f4d\u7f6e\u5f00\u5b54\u3002\u5916\u5899\u6253\u5b54\u5e94\u5411\u5916\u5899\u4fa7\u503e\u659c\uff0c\u9632\u6b62\u96e8\u6c34\u5012\u704c\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u5b54\u4f4d\u907f\u5f00\u6881\u5185\u4e3b\u7b4b\u4e0e\u6c34\u7535\u6697\u7ba1\uff0c\u5916\u5899\u5b54\u5411\u5916\u503e\u659c\uff08\u5916\u4f4e\u5185\u9ad8\uff09\uff0c\u5b54\u53e3\u65e0\u7834\u635f\u3001\u65e0\u6e17\u6c34\u75d5\u8ff9\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e34\uff1a\u5899\u9762\u5f00\u69fd\u3002<\/b>\u5f00\u69fd\u5728\u6253\u5b54\u4e4b\u540e\u8fdb\u884c\uff0c\u4f18\u5148\u7ad6\u5411\u5f00\u69fd\uff0c<b>\u627f\u91cd\u5899\u4e25\u7981\u6a2a\u5411\u5f00\u69fd<\/b>\u3002\u5f00\u69fd\u6df1\u5ea6\u4e0d\u5e94\u5927\u4e8e\u5899\u4f53\u539a\u5ea6\u7684 1\/3\uff0c\u52a0\u6c14\u5757\u5899\u4f53\u4e0d\u5b9c\u5927\u4e8e 30mm\uff1b\u69fd\u6df1\u5b9c\u4e3a\u7ba1\u5916\u5f84\u52a0 10~20mm\uff0c\u69fd\u5bbd\u5b9c\u4e3a\u7ba1\u5916\u5f84\u52a0 30~60mm\uff0c\u7ba1\u7ebf\u6577\u8bbe\u540e\u8868\u9762\u7802\u6d46\u4fdd\u62a4\u5c42\u4e0d\u5c0f\u4e8e 15mm\u3002\u5f00\u69fd\u5e94\u4f7f\u7528\u4e13\u7528\u5f00\u69fd\u673a\u5207\u5272\uff0c\u4e0d\u5f97\u7528\u7535\u9524\u6216\u5927\u9524\u968f\u610f\u5254\u51ff\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u627f\u91cd\u5899\u65e0\u6a2a\u5411\u69fd\uff1b\u69fd\u6df1\u4e0d\u8d85\u5899\u539a 1\/3\uff1b\u7ba1\u7ebf\u57cb\u597d\u6709\u4fdd\u62a4\u5c42\u8986\u76d6\uff1b\u69fd\u8fb9\u6574\u9f50\u4e0d\u5d29\u8fb9\u3002<\/p>\n<\/div>\n\n<h2>\u5341\u3001\u98ce\u53e3\u4e0e\u7ebf\u63a7\u5668\u5b89\u88c5\uff08\u6761\u6b3e35\u201337\uff09<\/h2>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e35\uff1a\u98ce\u53e3\u6d4b\u91cf\u3002<\/b>\u540a\u9876\u3001\u5899\u9762\u3001\u67dc\u4f53\u7b49\u88c5\u4fee\u57fa\u672c\u5b8c\u5de5\u540e\uff0c\u7531\u4e1a\u4e3b\u901a\u77e5\u7a7a\u8c03\u65bd\u5de5\u65b9\u5230\u73b0\u573a\u5b9e\u6d4b\u51fa\u98ce\u53e3\u3001\u56de\u98ce\u53e3\u7684\u5b9e\u9645\u5f00\u5b54\u5c3a\u5bf8\uff0c\u518d\u4ea4\u5de5\u5382\u5b9a\u5236\u3002\u6728\u5de5\u5f00\u5b54\u65f6\uff0c\u98ce\u53e3\u56db\u5468\u5e94\u52a0\u88c5\u6728\u6761\u52a0\u56fa\uff0c\u4f9b\u540e\u671f\u56fa\u5b9a\u8f6f\u8fde\u63a5\u548c\u98ce\u53e3\u8fb9\u6846\uff1b\u73b0\u573a\u5f00\u5b54\u4e0e\u5ba4\u5185\u673a\u51fa\u98ce\u53e3\u6709\u504f\u5dee\u7684\uff0c\u53ca\u65f6\u4e0e\u88c5\u4fee\u65b9\u6c9f\u901a\u8c03\u6574\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u6309\u5b9e\u6d4b\u5c3a\u5bf8\u5b9a\u5236\uff1b\u98ce\u53e3\u56db\u5468\u6709\u52a0\u56fa\u6728\u6761\uff1b\u98ce\u53e3\u88c5\u5b8c\u4e0e\u540a\u9876\u8d34\u5408\u4e25\u5bc6\u3001\u5916\u89c2\u6574\u9f50\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e36\uff1a\u98ce\u53e3\u5b89\u88c5\u3002<\/b>\u98ce\u53e3\u9762\u677f\u5230\u8d27\u540e\u7531\u7a7a\u8c03\u65bd\u5de5\u65b9\u5b89\u88c5\u3002\u5b89\u88c5\u524d\u628a\u51fa\u98ce\u53e3\u4e0a\u65b9\u7684\u8f6f\u8fde\u63a5\u5145\u5206\u5c55\u5f00\u3001\u5e73\u6574\u56fa\u5b9a\u5230\u5f00\u5b54\u56db\u5468\u7684\u6728\u6761\u4e0a\uff0c\u505a\u5230\u8fde\u63a5\u4e25\u5bc6\u3001\u65e0\u8936\u76b1\u3001\u4e0d\u6f0f\u98ce\uff1b\u8f6f\u8fde\u63a5\u957f\u5ea6\u63a7\u5236\u5728 100~200mm\uff0c\u5ba4\u5185\u673a\u51fa\u98ce\u53e3\u4e0e\u9001\u98ce\u53e3\u5bf9\u6b63\u3002\u56de\u98ce\u53e3\u540c\u6b65\u5b89\u88c5\u8fc7\u6ee4\u7f51\uff0c\u88c5\u5230\u4f4d\u3001\u5e73\u6574\u4e0d\u53d8\u5f62\u3001\u65b9\u4fbf\u540e\u671f\u62c6\u6d17\u3002\u98ce\u53e3\u5e94\u6a2a\u5e73\u7ad6\u76f4\u3001\u8868\u9762\u5e73\u6574\uff0c\u540c\u623f\u95f4\u540c\u6b3e\u98ce\u53e3\u9ad8\u5ea6\u4e00\u81f4\uff1b\u5e26\u8c03\u8282\u529f\u80fd\u7684\u98ce\u53e3\uff0c\u8c03\u8282\u88c5\u7f6e\u8f6c\u52a8\u7075\u6d3b\u3001\u5b9a\u4f4d\u53ef\u9760\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u8f6f\u8fde\u63a5\u4e0d\u76b1\u3001\u4e0d\u6f0f\u98ce\u3001\u957f\u5ea6 100~200mm\uff1b\u98ce\u53e3\u65e0\u5212\u75d5\u3001\u65e0\u660e\u663e\u8272\u5dee\u3001\u6392\u5217\u6574\u9f50\uff1b\u56de\u98ce\u8fc7\u6ee4\u7f51\u53ef\u62c6\u6d17\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e37\uff1a\u7ebf\u63a7\u5668\u5b89\u88c5\u3002<\/b>\u7ebf\u63a7\u5668\u5b89\u88c5\u5728\u524d\u671f\u9884\u7559\u7684\u5e95\u76d2\u5185\uff0c\u7262\u56fa\u3001\u7aef\u6b63\u3001\u4e0e\u5899\u9762\u8d34\u5408\u7d27\u5bc6\uff1b\u540c\u4e00\u623f\u95f4\u5185\u5e76\u5217\u5b89\u88c5\u7684\u7ebf\u63a7\u5668\u9ad8\u5ea6\u4e00\u81f4\u3002\u88c5\u5b8c\u64e6\u62ed\u5e72\u51c0\uff0c\u65e0\u5212\u75d5\u3001\u65e0\u6c61\u6e0d\uff1b\u901a\u7535\u6d4b\u8bd5\uff0c\u786e\u8ba4\u5404\u623f\u95f4\u7ebf\u63a7\u5668\u4e0e\u5ba4\u5185\u673a\u901a\u8baf\u6b63\u5e38\u3001\u63a7\u5236\u6709\u6548\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u901a\u7535\u9010\u4e2a\u8bd5\uff0c\u6bcf\u4e2a\u623f\u95f4\u90fd\u80fd\u6b63\u5e38\u63a7\u6e29\u3001\u663e\u793a\u6e05\u6670\u3002<\/p>\n<\/div>\n\n<h2>\u5341\u4e00\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u8bd5\u8fd0\u884c\u4e0e\u4ea4\u4ed8\uff08\u6761\u6b3e38\u201341\uff09<\/h2>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e38\uff1a\u771f\u7a7a\u5e72\u71e5\u3002<\/b>\u62bd\u771f\u7a7a\u524d\u786e\u8ba4\u6c14\u3001\u6db2\u7ba1\u622a\u6b62\u9600\u5904\u5728\u5173\u95ed\u72b6\u6001\uff0c\u7528\u5145\u6ce8\u5bfc\u7ba1\u628a\u771f\u7a7a\u6cf5\u8fde\u63a5\u5230\u6c14\u9600\u3001\u6db2\u9600\u7684\u68c0\u6d4b\u63a5\u5934\u4e0a\u3002\u771f\u7a7a\u5ea6\u5e94\u8fbe\u5230 <b>-0.1MPa\uff08-755mmHg\uff09\u4ee5\u4e0b\uff0c\u5e76\u4fdd\u6301 2h \u4ee5\u4e0a\uff0c\u7cfb\u7edf\u7edd\u5bf9\u538b\u529b\u65e0\u56de\u5347\u3001\u6307\u9488\u4e0d\u56de\u5f39<\/b>\u3002\u5173\u6cf5\u540e\u538b\u529b\u56de\u5347\u7684\uff0c\u7ee7\u7eed\u62bd\u771f\u7a7a\u5230\u5408\u683c\uff1b\u56de\u5347\u4e25\u91cd\u7684\uff0c\u67e5\u6f0f\u3001\u6d88\u6f0f\u540e\u91cd\u505a\u4fdd\u538b\u548c\u62bd\u771f\u7a7a\u8bd5\u9a8c\uff0c\u76f4\u5230\u5408\u683c\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u73b0\u573a\u770b\u771f\u7a7a\u8868\u2014\u2014\u7a33\u5b9a\u5728 -0.1MPa\u3001\u4fdd\u6301 2 \u5c0f\u65f6\u3001\u6307\u9488\u65e0\u56de\u5f39\uff0c\u624d\u7b97\u5408\u683c\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e39\uff1a\u5236\u51b7\u5242\u8ffd\u52a0\u5145\u6ce8\u3002<\/b>\u6309\u5382\u5bb6\u6280\u672f\u6587\u4ef6\u7684\u65b9\u6cd5\u8ba1\u7b97\u8ffd\u52a0\u5145\u6ce8\u91cf\uff0c\u7528\u9ad8\u7cbe\u5ea6\u79f0\u91cd\u8ba1\u8ba1\u91cf\uff0c\u5145\u6ce8\u540c\u79cd\u7c7b\u3001\u76f8\u5e94\u91cf\u7684\u5236\u51b7\u5242\uff0c\u4e0d\u53ef\u8fc7\u591a\u6216\u8fc7\u5c11\u3002\u5145\u6ce8\u5b8c\u6210\u540e\uff0c\u7528\u673a\u5668\u7684\u81ea\u52a8\u8bca\u65ad\u529f\u80fd\u6267\u884c\u5236\u51b7\u5242\u5224\u5b9a\u8fd0\u884c\uff1b\u5224\u5b9a\u4e0d\u8db3\u3001\u8fc7\u91cf\u6216\u5f02\u5e38\u7684\uff0c\u67e5\u660e\u539f\u56e0\u5904\u7406\u540e\u91cd\u8dd1\uff0c\u76f4\u5230\u5224\u5b9a\u5408\u683c\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u5145\u6ce8\u91cf\u6709\u79f0\u91cd\u8bb0\u5f55\uff1b\u673a\u5668\u81ea\u68c0\u5224\u5b9a\u901a\u8fc7\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e40\uff1a\u7cfb\u7edf\u8bd5\u8fd0\u884c\u3002<\/b>\u7531\u4e13\u4e1a\u8c03\u8bd5\u4eba\u5458\u5f00\u673a\u8c03\u8bd5\u8fd0\u884c\uff0c<b>\u8fd0\u884c\u65f6\u95f4\u4e0d\u5c0f\u4e8e 2 \u5c0f\u65f6<\/b>\uff0c\u5e76\u901a\u8fc7\u7ebf\u63a7\u5668\u70b9\u68c0\u529f\u80fd\u67e5\u770b\u7a7a\u8c03\u5404\u4f20\u611f\u5668\u6570\u636e\uff0c\u5bf9\u8fd0\u884c\u53c2\u6570\u5206\u6790\u786e\u8ba4\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u8bd5\u8fd0\u884c\u6ee1 2 \u5c0f\u65f6\uff1b\u7ebf\u63a7\u5668\u70b9\u68c0\u7684\u5404\u4f20\u611f\u5668\u6570\u636e\u65e0\u5f02\u5e38\u3002<\/p>\n<\/div>\n<div class=\"clause\">\n<p><b>\u6761\u6b3e41\uff1a\u7528\u6237\u4ea4\u4ed8\u3002<\/b>\u7531\u4e13\u4e1a\u8c03\u8bd5\u4eba\u5458\u5411\u7528\u6237\u505a\u4f7f\u7528\u53ca\u6ce8\u610f\u4e8b\u9879\u57f9\u8bad\uff0c\u4ea4\u4ed8\u5185\u5bb9\u5305\u62ec\uff1a\u4ea7\u54c1\u4f7f\u7528\u65b9\u6cd5\u3001\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\u3001\u624b\u673a APP\u3001\u7ebf\u63a7\u5668\u4e8c\u7ef4\u7801\u3001\u4fdd\u4fee\u7535\u8bdd\u3001\u4fdd\u4fee\u671f\u3001\u4fdd\u517b\u5e38\u8bc6\u3001\u516c\u4f17\u53f7\u3002<\/p>\n<p>\u2705 <span class=\"chk\">\u9a8c\u6536\u8981\u70b9\uff1a<\/span>\u4f7f\u7528\u57f9\u8bad\u5f53\u9762\u505a\u8fc7\uff1b\u4fdd\u4fee\u7535\u8bdd\u3001\u4fdd\u4fee\u671f\u548c\u4fdd\u517b\u5e38\u8bc6\u5199\u8fdb\u4ea4\u4ed8\u5355\u3002\u53e6\uff1a\u65e5\u7acb\u300c\u5341\u5e74\u5305\u4fee\u300d\u4e3a\u9650\u65f6\u6d3b\u52a8\uff082026-09-08 \u81f3 2026-10-12\uff09\uff0c\u5230\u671f\u540e\u662f\u5426\u5ef6\u7eed\uff0c\u4ee5\u65e5\u7acb\u5b98\u65b9\u4e0b\u4e00\u8f6e\u901a\u77e5\u4e3a\u51c6\u3002<\/p>\n<\/div>\n\n<h2>\u6210\u90fd\u672c\u5730\u65bd\u5de5\u9ad8\u9891\u8e29\u5751\u63d0\u9192<\/h2>\n<ul class=\"pit\">\n<li><b>\u4e0d\u5145\u6c2e\u6c14\u710a\u63a5<\/b>\u2192\u94dc\u7ba1\u5185\u58c1\u6c27\u5316\u76ae\u8131\u843d\uff0c\u5835\u585e\u7535\u5b50\u81a8\u80c0\u9600\u3001\u635f\u574f\u538b\u7f29\u673a\u3002<\/li>\n<li><b>\u4fdd\u538b\u65f6\u95f4\u4e0d\u8db3 \/ \u538b\u529b\u4e0d\u591f<\/b>\u2192\u9690\u6027\u6cc4\u6f0f\uff0c\u5c01\u677f\u540e\u624d\u53d1\u73b0\uff0c\u8fd4\u5de5\u6210\u672c\u9ad8\u3002<\/li>\n<li><b>\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u4e0d\u8db3<\/b>\u2192\u6392\u6c34\u4e0d\u7545\u5012\u6d41\uff0c\u6ce1\u540a\u9876\u3001\u5899\u9762\u6e17\u6c34\u53d1\u9709\u3002<\/li>\n<li><b>\u5185\u673a\u79bb\u5899\/\u9876\u8ddd\u4e0d\u591f<\/b>\u2192\u540a\u9876\u5171\u632f\u5f02\u54cd\u3001\u56de\u98ce\u4e0d\u8db3\u5236\u51b7\u5dee\u3002<\/li>\n<li><b>\u5916\u673a\u79bb\u5899\u4e0d\u8db3200mm \/ \u767e\u53f6\u901a\u98ce\u5dee<\/b>\u2192\u6563\u70ed\u4e0d\u826f\u3001\u538b\u7f29\u673a\u9ad8\u6e29\u8001\u5316\u3002<\/li>\n<\/ul>\n<h2>\u9a8c\u6536\u4e3a\u4ec0\u4e48\u662f\"\u7cfb\u7edf\u9a8c\u6536\"\uff0c\u4e0d\u662f\"\u8bbe\u5907\u68c0\u67e5\"<\/h2>\n<p>\u5f88\u591a\u4e1a\u4e3b\u9a8c\u6536\u4e2d\u592e\u7a7a\u8c03\uff0c\u770b\u7684\u662f\"\u673a\u5668\u88c5\u6ca1\u88c5\u597d\"\u3002\u4f46\u771f\u6b63\u51b3\u5b9a\u7528\u8d77\u6765\u8212\u4e0d\u8212\u670d\u7684\uff0c\u662f\u56db\u6837\u4e1c\u897f\u914d\u4e0d\u914d\uff1a<b>\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236<\/b>\u3002\u5355\u770b\u67d0\u4e00\u53f0\u5185\u673a\uff0c\u770b\u4e0d\u51fa\u7cfb\u7edf\u95ee\u9898\u3002<\/p>\n<p>\u9f99\u8109\u7684\u9a8c\u6536\u6309\u56db\u8981\u7d20\u9010\u9879\u5bf9\uff1a<\/p>\n<table>\n<thead><tr><th>\u8981\u7d20<\/th><th>\u9a8c\u6536\u770b\u4ec0\u4e48<\/th><th>\u5bf9\u5e94\u6761\u6b3e<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><b>\u8f93\u914d<\/b><\/td><td>\u94dc\u7ba1\u58c1\u539a\u4e0e\u710a\u63a5\u3001\u4fdd\u538b 4.15MPa\u3001\u62bd\u771f\u7a7a\u5230 -0.1MPa<\/td><td>\u6761\u6b3e 13\u201318\u300131\u300138<\/td><\/tr>\n<tr><td><b>\u672b\u7aef<\/b><\/td><td>\u5185\u673a\u6c34\u5e73\u3001\u68c0\u4fee\u53e3\u5c3a\u5bf8\u3001\u51b7\u51dd\u6c34\u5761\u5ea6\u3001\u98ce\u53e3\u4f4d\u7f6e<\/td><td>\u6761\u6b3e 3\u20136\u300121\u201326\u300135\u201337<\/td><\/tr>\n<tr><td><b>\u63a7\u5236<\/b><\/td><td>\u7ebf\u63a7\u5668\u4e0e\u7535\u6e90\u7ebf\u9694\u79bb\u3001\u901a\u8baf\u7ebf\u89c4\u8303\u3001\u6f0f\u7535\u4fdd\u62a4<\/td><td>\u6761\u6b3e 28\u201330<\/td><\/tr>\n<tr><td><b>\u70ed\u6e90<\/b><\/td><td>\u5916\u673a\u56fa\u5b9a\u4e0e\u6563\u70ed\u7a7a\u95f4\u3001\u7535\u6e90\u72ec\u7acb\u56de\u8def<\/td><td>\u6761\u6b3e 7\u201312<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p><b>\u6362\u4e2a\u8bf4\u6cd5<\/b>\uff1a\u88c5\u4e00\u53f0\u673a\u5668\u662f\"\u4e70\u4e86\"\uff0c\u88c5\u4e00\u5957\u7cfb\u7edf\u662f\"\u914d\u597d\u62ff\"\u3002\u6563\u70ed\u7a7a\u95f4\u7559\u4e0d\u591f\uff0c\u673a\u5668\u518d\u597d\u4e5f\u8d39\u7535\uff1b\u51b7\u51dd\u6c34\u5761\u4e0d\u591f\uff0c\u88c5\u5f97\u518d\u6f02\u4eae\u4e5f\u8981\u6f0f\u3002\u9a8c\u6536\u5c31\u662f\u5728\u8fd9\u56db\u6837\u90fd\u914d\u5230\u4f4d\u3001\u5c01\u677f\u4e4b\u524d\uff0c\u4e00\u6837\u4e00\u6837\u8fc7\u4e00\u904d\u3002<\/p>\n<p>\u6240\u4ee5\u6211\u4eec\u628a\u6bcf\u9053\u5de5\u5e8f\u505a\u6210\u68c0\u67e5\u5355\uff1a<b>\u4e0d\u5408\u683c\u4e0d\u8fdb\u5165\u4e0b\u4e00\u6b65\uff0c\u9010\u9879\u7b7e\u5b57\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8<\/b>\u3002\u8fd9\u5f20\u5355\u5b50\u4e0d\u662f\u8d70\u5f62\u5f0f\u2014\u2014\u5c01\u677f\u4e4b\u540e\uff0c\u7ba1\u5b50\u90fd\u5728\u5899\u91cc\u548c\u540a\u9876\u91cc\uff0c\u90a3\u65f6\u5019\u518d\u53d1\u73b0\u95ee\u9898\uff0c\u62c6\u9876\u7684\u6210\u672c\u6bd4\u88c5\u7684\u65f6\u5019\u9ad8\u5f97\u591a\u3002<\/p>\n\n<h2>\u5e38\u89c1\u9a8c\u6536\u7591\u95ee<\/h2>\n<div class=\"faq-item\">\n<h3>\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u540e\u600e\u4e48\u9a8c\u6536\uff1f\u91cd\u70b9\u770b\u54ea\u4e9b\uff1f<\/h3>\n<div class=\"faq-ans\">\u5c01\u677f\u524d\u91cd\u70b9\u6838\u67e5\uff1a\u5185\u673a\u79bb\u5899\u2265100mm\u3001\u5916\u673a\u79bb\u5899\u2265200mm\uff1b\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u65e0\u6c27\u5316\u76ae\uff1b\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22655\u2030\uff1b\u6c2e\u6c14\u4fdd\u538b 4.15MPa \u7ef4\u6301 24h \u538b\u529b\u4e0d\u964d\u3002\u5bf9\u7167\u672c\u9875\u5341\u4e00\u4e2a\u90e8\u5206\u9010\u9879\u786e\u8ba4\u5373\u53ef\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>\u4e3a\u4ec0\u4e48\u6253\u5b54\u8981\u907f\u5f00\u94a2\u7b4b\u3001\u5411\u5916\u503e\u659c\uff1f<\/h3>\n<div class=\"faq-ans\">\u623f\u6881\u94a2\u7b4b\u591a\u5728\u4e24\u4fa7\uff0c\u6253\u9519\u4f1a\u7834\u574f\u627f\u91cd\u7ed3\u6784\uff1b\u5916\u5899\u5b54\u5411\u5916\u5899\u4fa7\u503e\u659c\u53ef\u9632\u6b62\u96e8\u6c34\u6cbf\u5b54\u5012\u704c\u8fdb\u5ba4\u5185\uff0c\u907f\u514d\u5899\u9762\u6e17\u6c34\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u6709\u4ec0\u4e48\u7528\uff1f\u4e0d\u505a\u4f1a\u600e\u6837\uff1f<\/h3>\n<div class=\"faq-ans\">\u710a\u63a5\u65f6\u901a\u6c2e\u6c14\u7f6e\u6362\u7ba1\u5185\u7a7a\u6c14\uff0c\u9632\u6b62\u94dc\u7ba1\u5185\u58c1\u751f\u6210\u6c27\u5316\u76ae\u3002\u4e0d\u505a\u5219\u6c27\u5316\u76ae\u968f\u51b7\u5a92\u5faa\u73af\uff0c\u6613\u5835\u585e\u7535\u5b50\u81a8\u80c0\u9600\u3001\u78e8\u635f\u538b\u7f29\u673a\uff0c\u5bfc\u81f4\u7a7a\u8c03\u762b\u75ea\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>\u6c14\u5bc6\u6027\u8bd5\u9a8c\u4e3a\u4ec0\u4e48\u8981\u4fdd\u538b 24 \u5c0f\u65f6\uff1f<\/h3>\n<div class=\"faq-ans\">4.15MPa \u4fdd\u538b 24h \u662f\u9a8c\u8bc1\u5168\u90e8\u94dc\u7ba1\u63a5\u5934\u65e0\u6cc4\u6f0f\u7684\u6700\u7ec8\u624b\u6bb5\uff0c\u4e5f\u662f\u9690\u853d\u5de5\u7a0b\u6700\u5173\u952e\u9a8c\u6536\u8282\u70b9\u3002\u5408\u683c\u540e\u624d\u653e\u5fc3\u5c01\u677f\uff0c\u907f\u514d\u540e\u671f\u6316\u540a\u9876\u8fd4\u5de5\u3002<\/div>\n<\/div>\n\n<div class=\"faq-item\">\n<h3>\u5899\u9762\u5f00\u69fd\u6709\u4ec0\u4e48\u8bb2\u7a76\uff1f\u627f\u91cd\u5899\u80fd\u5f00\u69fd\u5417\uff1f<\/h3>\n<div class=\"faq-ans\">\u4f18\u5148\u7ad6\u5411\u5f00\u69fd\uff0c\u627f\u91cd\u5899\u4e25\u7981\u6a2a\u5411\u5f00\u69fd\u3002\u5f00\u69fd\u6df1\u5ea6\u4e0d\u5927\u4e8e\u5899\u539a\u7684 1\/3\uff0c\u52a0\u6c14\u5757\u5899\u4f53\u4e0d\u5927\u4e8e 30mm\uff1b\u69fd\u6df1\u4e3a\u7ba1\u5916\u5f84\u52a0 10~20mm\uff0c\u69fd\u5bbd\u4e3a\u7ba1\u5916\u5f84\u52a0 30~60mm\uff0c\u7ba1\u7ebf\u6577\u8bbe\u540e\u8868\u9762\u7802\u6d46\u4fdd\u62a4\u5c42\u4e0d\u5c0f\u4e8e 15mm\u3002\u8981\u7528\u4e13\u7528\u5f00\u69fd\u673a\u5207\u5272\uff0c\u4e0d\u80fd\u7528\u7535\u9524\u6216\u5927\u9524\u968f\u610f\u5254\u51ff\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>\u4e2d\u592e\u7a7a\u8c03\u88c5\u5b8c\u62bd\u771f\u7a7a\u8981\u591a\u4e45\uff1f\u600e\u4e48\u7b97\u5408\u683c\uff1f<\/h3>\n<div class=\"faq-ans\">\u771f\u7a7a\u5ea6\u8981\u62bd\u5230 -0.1MPa\uff08-755mmHg\uff09\u4ee5\u4e0b\uff0c\u4fdd\u6301 2 \u5c0f\u65f6\u4ee5\u4e0a\uff0c\u5173\u6cf5\u540e\u6307\u9488\u4e0d\u56de\u5f39\uff0c\u624d\u7b97\u5408\u683c\u3002\u62bd\u771f\u7a7a\u662f\u4e3a\u4e86\u6392\u6389\u7ba1\u8def\u91cc\u7684\u7a7a\u6c14\u548c\u6c34\u5206\uff0c\u4e0d\u8fbe\u6807\u4f1a\u5bfc\u81f4\u51b0\u5835\u3001\u6c27\u5316\uff0c\u751a\u81f3\u635f\u574f\u538b\u7f29\u673a\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>\u98ce\u53e3\u4ec0\u4e48\u65f6\u5019\u91cf\u3001\u4ec0\u4e48\u65f6\u5019\u88c5\uff1f<\/h3>\n<div class=\"faq-ans\">\u540a\u9876\u3001\u5899\u9762\u3001\u67dc\u4f53\u88c5\u4fee\u57fa\u672c\u5b8c\u5de5\u540e\uff0c\u518d\u73b0\u573a\u5b9e\u6d4b\u51fa\u98ce\u53e3\u3001\u56de\u98ce\u53e3\u7684\u5b9e\u9645\u5f00\u5b54\u5c3a\u5bf8\uff0c\u4ea4\u5de5\u5382\u5b9a\u5236\uff1b\u98ce\u53e3\u9762\u677f\u5230\u8d27\u540e\u518d\u5b89\u88c5\u3002\u8f6f\u8fde\u63a5\u8981\u5c55\u5f00\u94fa\u5e73\uff0c\u8fde\u63a5\u4e25\u5bc6\u3001\u4e0d\u8936\u76b1\u3001\u4e0d\u6f0f\u98ce\uff0c\u957f\u5ea6\u63a7\u5236\u5728 100~200mm\uff1b\u56de\u98ce\u53e3\u8981\u540c\u6b65\u88c5\u8fc7\u6ee4\u7f51\uff0c\u65b9\u4fbf\u540e\u671f\u62c6\u6d17\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>\u4e2d\u592e\u7a7a\u8c03\u88c5\u5b8c\u600e\u4e48\u8bd5\u673a\uff1f\u4ea4\u4ed8\u65f6\u7ed9\u4ec0\u4e48\uff1f<\/h3>\n<div class=\"faq-ans\">\u7531\u8c03\u8bd5\u4eba\u5458\u5f00\u673a\u8bd5\u8fd0\u884c\u4e0d\u5c11\u4e8e 2 \u5c0f\u65f6\uff0c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u5404\u9879\u4f20\u611f\u5668\u6570\u636e\u786e\u8ba4\u6b63\u5e38\uff1b\u7136\u540e\u5f53\u9762\u5411\u7528\u6237\u505a\u4f7f\u7528\u57f9\u8bad\uff0c\u4ea4\u4ed8\u4ea7\u54c1\u4f7f\u7528\u65b9\u6cd5\u3001\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\u3001\u624b\u673a APP\u3001\u7ebf\u63a7\u5668\u4e8c\u7ef4\u7801\u3001\u4fdd\u4fee\u7535\u8bdd\u3001\u4fdd\u4fee\u671f\u548c\u4fdd\u517b\u5e38\u8bc6\u3002<\/div>\n<\/div>\n<section style=\"margin:36px 0;padding:22px 24px;background:#f5f8fc;border-left:4px solid #E8541E;border-radius:10px;\">\n  <h3 style=\"margin:0 0 12px;color:#12314F;font-size:18px;font-weight:700;\">\u76f8\u5173\u9605\u8bfb \u00b7 \u65e5\u7acb\u5341\u5e74\u5305\u4fee\u4e0e\u5f53\u524d\u6d3b\u52a8<\/h3>\n  <ul style=\"margin:0;padding-left:22px;line-height:2.1;color:#1f2d3d;\">\n    <li style=\"margin:0;\"><a href=\"https:\/\/longmai-nt.com\/?page_id=12258\" target=\"_blank\" rel=\"noopener\" style=\"color:#12314F;text-decoration:none;border-bottom:1px solid #E8541E;\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u300c\u5341\u5e74\u5305\u4fee\u300d\u653f\u7b56\u8be6\u89e3\uff1a\u4ea7\u54c110\u5e74+\u5b89\u88c510\u5e74\uff0c\u5382\u5bb6\u5148\u670d\u52a1\u540e\u8ffd\u8d23<\/a><\/li>\n    <li style=\"margin:0;\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1369\" target=\"_blank\" rel=\"noopener\" style=\"color:#12314F;text-decoration:none;border-bottom:1px solid #E8541E;\">\u65e5\u7acb\u91d1\u79cb\u53cc\u8282\u00b7\u9f99\u8109\u4f1a\u5458\u8054\u5408\u5b63\uff1a\u5382\u8865\u6700\u9ad8\u62b52000\u5143\uff0c\u7b7e\u7ea6\u5373\u4eab10\u5e74\u5305\u4fee<\/a><\/li>\n  <\/ul>\n\n  <p style=\"margin:10px 0 0;font-size:.84rem;color:#666;\">\u8bf4\u660e\uff1a\u65e5\u7acb\u300c\u5341\u5e74\u5305\u4fee\u300d\u4e3a\u9650\u65f6\u6d3b\u52a8\uff082026-09-08 \u81f3 2026-10-12\uff09\uff0c\u5230\u671f\u540e\u662f\u5426\u5ef6\u7eed\uff0c\u4ee5\u65e5\u7acb\u5b98\u65b9\u4e0b\u4e00\u8f6e\u901a\u77e5\u4e3a\u51c6\u3002<\/p><\/section>\n\n<h3>\u76f8\u5173\u53c2\u8003\uff08\u6b63\u6587\u5185\u94fe\uff09<\/h3>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\"><span class=\"title\">\u7cbe\u5de5\u516d\u6b65\u6cd5\u603b\u89c8<\/span><span class=\"desc\">\u9f99\u8109\u65bd\u5de5\u6807\u51c6\u5168\u53e3\u5f84<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\"><span class=\"title\">\u670d\u52a1\u4fdd\u969c<\/span><span class=\"desc\">\u5341\u5e74\u4fdd\u969c\u4e0e\u552e\u540e\u627f\u8bfa<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10970\" target=\"_blank\"><span class=\"title\">\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4ef7\u683c\u8868<\/span><span class=\"desc\">\u673a\u578b\u7cfb\u5217\u4e0e\u53c2\u8003\u62a5\u4ef7<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=9937\" target=\"_blank\"><span class=\"title\">\u5149\u534e\u9526\u82d1\uff5c\u8001\u623f\u52a0\u88c5\u660e\u88c5\u6696\u6c14\u7247\u6848\u4f8b<\/span><span class=\"desc\">\u540c\u5de5\u827a\u5b9e\u666f\u53c2\u8003<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10886\" target=\"_blank\"><span class=\"title\">\u7eff\u5730468\u516c\u9986\uff5c\u83f2\u65af\u66fc\u4e24\u7528\u7089\u6848\u4f8b<\/span><span class=\"desc\">\u8bbe\u5907\u8fdb\u573a\u4e0e\u5b89\u88c5\u5b9e\u666f<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\"><span class=\"title\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\u4ea7\u54c1\u9875<\/span><span class=\"desc\">\u8fd9\u4e9b\u6807\u51c6\u88c5\u7684\u662f\u54ea\u6b3e\u673a\u5668<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=14150\" target=\"_blank\"><span class=\"title\">\u5c0a\u777f\u5168\u6548\u2161\u503c\u4e0d\u503c\u5f97\u4e70<\/span><span class=\"desc\">\u9002\u5408\u8c01 \u00b7 \u8d35\u5728\u54ea \u00b7 \u6210\u90fd\u591a\u5c11\u94b1<\/span><\/a>\n<h2>\u770b\u5b8c\u9a8c\u6536\u6761\u6b3e\uff0c\u4e0b\u4e00\u6b65\u770b\u4ec0\u4e48<\/h2>\n<p>\u8fd9\u4e00\u9875\u662f\"\u600e\u4e48\u9a8c\"\u2014\u2014\u9010\u6761\u5bf9\u7167\uff0c\u5c01\u677f\u4e4b\u524d\u628a\u7ba1\u5b50\u3001\u4fdd\u538b\u3001\u62bd\u771f\u7a7a\u3001\u98ce\u53e3\u4e00\u9879\u9879\u8fc7\u5b8c\u3002<\/p>\n<p>\u5982\u679c\u60a8\u8fd8\u6ca1\u5b9a\u65b9\u6848\u3001\u60f3\u5148\u5f04\u660e\u767d\"\u8fd9\u5957\u7cfb\u7edf\u8be5\u600e\u4e48\u914d\u3001\u6bcf\u4e2a\u73af\u8282\u8c01\u8d1f\u8d23\u3001\u51fa\u4e86\u95ee\u9898\u627e\u8c01\"\uff0c\u8bf7\u5148\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=6342\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u65bd\u5de5\u5168\u8fc7\u7a0b\u4e0e\u8d23\u4efb\u5206\u5de5<\/a>\u3002\u90a3\u4e00\u9875\u8bb2\u7684\u662f\u4ece\u4e0a\u95e8\u52d8\u6d4b\u5230\u4ea4\u4ed8\u7684\u6574\u6761\u6d41\u7a0b\uff0c\u6bcf\u4e00\u6bb5\u8be5\u505a\u4ec0\u4e48\u3001\u505a\u5b8c\u8c01\u7b7e\u5b57\u3001\u7559\u4e0b\u4ec0\u4e48\u51ed\u636e\uff0c\u90fd\u5728\u91cc\u9762\u3002<\/p>\n<p>\u4e24\u9875\u914d\u5408\u770b\uff1a<b>6342 \u8bb2\"\u6d41\u7a0b\u4e0e\u8d23\u4efb\"\uff0c11380 \u8bb2\"\u9a8c\u6536\u6807\u51c6\"<\/b>\u3002\u88c5\u4e4b\u524d\u770b 6342\uff0c\u88c5\u5230\u4e00\u534a\u770b 11380\uff0c\u9a8c\u6536\u65f6\u4e24\u9875\u5bf9\u7740\u5355\u5b50\u8d70\uff0c\u5c31\u4e0d\u4f1a\u6f0f\u9879\u3002<\/p>\n\n<h2>\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<!-- ========== \u95e8\u5e97\u5b9e\u666f\u56fe\uff08\u53cc\u95e8\u5e97 + \u53cc\u7535\u8bdd\uff09 ========== -->\n<div class=\"lm-store-grid\">\n  <div class=\"lm-store\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\u5b9e\u666f\u00b7\u6210\u90fd\u9ad8\u65b0\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\" loading=\"lazy\">\n    <div class=\"name\">\u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/div>\n    <div>\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/div>\n    <div>\ud83d\udcde <a href=\"tel:02886131795\">028-86131795<\/a><\/div>\n    <div>\ud83d\udccd <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892|30.598786|104.074284|30.605656&amp;query_type=IDQ&amp;query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)&amp;zoom=17\" target=\"_blank\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97<\/a><\/div>\n  <\/div>\n  <div class=\"lm-store\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\u5b9e\u666f\u00b7\u6210\u90fd\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a\" loading=\"lazy\">\n    <div class=\"name\">\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/div>\n    <div>\u6210\u90fd\u00b7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a A5135<\/div>\n    <div>\ud83d\udcde <a href=\"tel:02865272586\">028-65272586<\/a><\/div>\n    <div>\ud83d\udccd <a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547|30.599807|104.07041|30.604665&amp;query_type=IDQ&amp;query=\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986(\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97)&amp;zoom=17.5\" target=\"_blank\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97<\/a><\/div>\n  <\/div>\n<\/div>\n\n<!-- ========== CTA ========== -->\n<div class=\"cta-box\">\n  <h3>\ud83d\udcde \u6210\u90fd\u5de5\u5730\u53c2\u89c2 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h3>\n  <p>\u514d\u8d39\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b \/ \u770b\u6210\u90fd\u672c\u5730\u5728\u5efa\u5de5\u5730\u5b9e\u62cd<\/p>\n  <p><a href=\"tel:02886131795\">028-86131795<\/a>\uff08\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff09\u3000<a href=\"tel:02865272586\">028-65272586<\/a>\uff08\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff09<\/p>\n  <p style=\"font-size:.9rem\">\ud83d\udccd \u53ef\u5bfc\u822a\u5230\u5e97\u5b9e\u5730\u4f53\u9a8c\u8bbe\u5907<\/p>\n  <p style=\"font-size:.82rem;color:#666\">\u670d\u52a1\u8303\u56f4\uff1a\u9ad8\u65b0\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u9a7f\u3001\u5929\u5e9c\u65b0\u533a\u3001\u9752\u7f8a\u3001\u6210\u534e\u3001\u89c6\u9ad8<\/p>\n<\/div>\n\n<h3>\u5ef6\u4f38\u9605\u8bfb<\/h3>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11074\" target=\"_blank\"><span class=\"title\">\u58c1\u6302\u7089\u600e\u4e48\u9009\uff08Hub\uff09<\/span><span class=\"desc\">\u91c7\u6696\u8bbe\u5907\u9009\u578b\u907f\u5751<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10982\" target=\"_blank\"><span class=\"title\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c\u8868<\/span><span class=\"desc\">\u8001\u623f\u88c5\u6696\u6c14\u542b\u9505\u7089\u5957\u9910<\/span><\/a>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\"><span class=\"title\">\u7ad9\u70b9\u5730\u56fe<\/span><span class=\"desc\">\u5168\u7ad9\u4ea7\u54c1\/\u767d\u76ae\u4e66\u7d22\u5f15<\/span><\/a>\n<div style=\"margin:40px 0 8px;border-top:3px solid #12314F;padding-top:22px;\">\n  <h2 style=\"font-size:24px;line-height:1.4;color:#12314F;margin:0 0 6px;\">\u5927\u529f\u7387\u8bbe\u5907\u7684\u7535\uff0c\u8c01\u6765\u505a<\/h2>\n  <p style=\"font-size:16px;line-height:1.9;color:#4a4a4a;margin:0 0 18px;\">\u7a7a\u8c03\u3001\u9505\u7089\u3001\u5faa\u73af\u6cf5\u8fd9\u4e9b\u8bbe\u5907\u7684\u56de\u8def\u548c\u7ebf\u5f84\uff0c\u5c5e\u4e8e\u5bb6\u88c5\u9690\u853d\u5de5\u7a0b\u7684\u4e00\u90e8\u5206\u3002\u6211\u4eec\u505a\u6696\u901a\u7684\u8fd9\u8fb9\u53ea\u7ba1\u8bbe\u5907\uff0c\u628a\u7535\u7559\u591f\u3001\u7559\u5bf9\uff0c\u662f\u6c34\u7535\u8fd9\u4e00\u6b65\u8981\u5148\u5b9a\u7684\u4e8b\u3002\u8fd9\u4e00\u6b65\u7684\u6807\u51c6\u5199\u5728\u9f99\u8109\u667a\u80fd\u7684\u5bb6\u5ead\u7535\u8def\u8bbe\u8ba1\u767d\u76ae\u4e66\u91cc\u3002<\/p>\n  <div style=\"display:flex;flex-wrap:wrap;gap:12px;\">\n    <a href=\"https:\/\/longmai-zn.com\/jiating-dianlisheji-bps\/\" style=\"display:block;flex:1 1 240px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;background:#fff;\" target=\"_blank\" rel=\"noopener noreferrer\">\u5bb6\u5ead\u7535\u8def\u8bbe\u8ba1\u767d\u76ae\u4e66\uff08\u9f99\u8109\u667a\u80fd\uff09<\/a>\n    <a href=\"https:\/\/longmai-zn.com\/jiazhuang-jishui-xitong-baipishu\/\" style=\"display:block;flex:1 1 240px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;background:#fff;\" target=\"_blank\" rel=\"noopener noreferrer\">\u5bb6\u88c5\u7ed9\u6c34\u7cfb\u7edf\u767d\u76ae\u4e66\uff08\u9f99\u8109\u667a\u80fd\uff09<\/a>\n  <\/div>\n  <p style=\"font-size:14px;line-height:1.8;color:#7a7a7a;margin:14px 0 0;\">\u9f99\u8109\u667a\u80fd\u662f\u9f99\u8109\u6696\u901a\u7684\u5173\u8054\u4f01\u4e1a\uff0c\u4e24\u5bb6\u662f\u4e0d\u540c\u4e3b\u4f53\uff0c\u7535\u8def\u4e0e\u7ed9\u6c34\u7684\u6d3b\u5206\u5934\u505a\u3002<\/p>\n<\/div>\n\n<div style=\"margin:26px 0;padding:16px 18px;background:#f0f7ff;border-left:4px solid #1a6fc4;border-radius:8px;\" data-page-node-id=\"FCkLiDRpzxB0mzRMgrtbK7\">\n  <div style=\"font-size:15px;font-weight:700;color:#1a2b3c;margin-bottom:6px;\" data-page-node-id=\"E5W1VrQd1vY0QnwA0Hc0zK\">\u4e3a\u4ec0\u4e48\u8fd9\u4e09\u9053\u5de5\u5e8f\u4e0d\u80fd\u7701\uff1f<\/div>\n  <div style=\"font-size:14px;line-height:1.8;color:#3c4d5c;margin-bottom:10px;\" data-page-node-id=\"hxYdWGtZlwBxERo4aPhY3k\">\n    \u5145\u6c2e\u4fdd\u62a4\u710a\u30014.0MPa \u4fdd\u538b 24 \u5c0f\u65f6\u3001\u62bd\u771f\u7a7a\u5230 -0.1MPa\u2014\u2014\u767d\u76ae\u4e66\u7b2c\u4e94\u7ae0\u5199\u4e86\u7701\u6389\u4efb\u4f55\u4e00\u6b65\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\uff0c\u4ee5\u53ca\u600e\u4e48\u73b0\u573a\u76ef\u3002\n  <\/div>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"display:inline-block;padding:9px 15px;background:#1a6fc4;color:#fff;border-radius:6px;text-decoration:none;font-size:14px;font-weight:600;\" data-page-node-id=\"9CkoCBYEIVl8FgWUfdJiAE\">\n    \u770b\u5b89\u88c5\u9a8c\u6536\u5b8c\u6574\u6807\u51c6\uff1a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66 V3.0\n  <\/a>\n<\/div>\n\n<\/div>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"@id\": \"https:\/\/longmai-nt.com\/?page_id=11380#article\",\n  \"headline\": \"\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u6210\u90fd\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u89c4\u8303\",\n  \"description\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03+\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff1a\u6761\u6b3e1\u201341\uff0c\u8986\u76d6\u65bd\u5de5\u524d\u51c6\u5907\u3001\u5185\u5916\u673a\u5b89\u88c5\u3001\u6253\u5b54\u4e0e\u5f00\u69fd\u3001\u51b7\u5a92\u914d\u7ba1\u710a\u63a5\u3001\u7ba1\u8def\u7cfb\u7edf\u3001\u7535\u6c14\u63a7\u5236\u3001\u6c14\u5bc6\u8bd5\u9a8c\u3001\u6750\u6599\u8fdb\u573a\u3001\u98ce\u53e3\u4e0e\u7ebf\u63a7\u5668\u3001\u7cfb\u7edf\u8c03\u8bd5\u8bd5\u8fd0\u884c\u3001\u7528\u6237\u4ea4\u4ed8\u3002\u88c5\u4fee\u5c01\u677f\u524d\u9010\u9879\u5bf9\u7167\u81ea\u67e5\u3002\",\n  \"author\": {\n    \"@type\": \"Person\",\n    \"@id\": \"https:\/\/longmai-nt.com\/#person-miaoyi\",\n    \"name\": \"\u7f2a\u5f02\"\n  },\n  \"publisher\": {\n    \"@id\": \"https:\/\/longmai-nt.com\/#organization\"\n  },\n  \"inLanguage\": \"zh-CN\",\n  \"datePublished\": \"2026-08-24\",\n  \"dateModified\": \"2026-10-08\",\n  \"mainEntityOfPage\": {\n    \"@id\": \"https:\/\/longmai-nt.com\/?page_id=11380\"\n  },\n  \"isPartOf\": {\n    \"@id\": \"https:\/\/longmai-nt.com\/#hvacbusiness\"\n  }\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"HowTo\",\n  \"name\": \"\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\",\n  \"description\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\u57fa\u4e8e\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u89c4\u8303\u7684\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03+\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6d41\u7a0b\uff0c\u542b\u65bd\u5de5\u524d\u51c6\u5907\u3001\u6253\u5b54\u4e0e\u5f00\u69fd\u3001\u5ba4\u5185\u5916\u673a\u5b89\u88c5\u3001\u51b7\u5a92\u914d\u7ba1\u710a\u63a5\u3001\u7ba1\u8def\u7cfb\u7edf\u3001\u7535\u6c14\u63a7\u5236\u3001\u6c14\u5bc6\u8bd5\u9a8c\u3001\u6750\u6599\u8fdb\u573a\u3001\u98ce\u53e3\u4e0e\u7ebf\u63a7\u5668\u3001\u7cfb\u7edf\u8c03\u8bd5\u8bd5\u8fd0\u884c\u3001\u7528\u6237\u4ea4\u4ed8\u5341\u4e00\u4e2a\u90e8\u5206\u517141\u9879\u53ef\u91cf\u5316\u9a8c\u6536\u8981\u70b9\u3002\",\n  \"step\": [\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u65bd\u5de5\u524d\u51c6\u5907\",\n      \"text\": \"\u6761\u6b3e1\u65bd\u5de5\u56fe\u786e\u8ba4\uff1a\u73b0\u573a\u4ea4\u5e95\u6709\u56fe\u53ef\u4f9d\uff0c\u7a7a\u8c03\u4e0e\u88c5\u4fee\u534f\u8c03\uff1b\u6761\u6b3e2\u65bd\u5de5\u5de5\u5177\uff1a\u5207\u7ba1\u5668\u3001\u5012\u89d2\u5668\u3001\u6269\u7ba1\u5668\u3001\u80c0\u7ba1\u5668\u3001\u5f2f\u7ba1\u5668\u7b49\u4e13\u7528\u5de5\u5177\u5230\u4f4d\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u6253\u5b54\u4e0e\u5899\u9762\u5f00\u69fd\",\n      \"text\": \"\u6761\u6b3e33\u6253\u5b54\uff1a\u4e0e\u4e1a\u4e3b\u7269\u4e1a\u786e\u8ba4\uff0c\u907f\u5f00\u6881\u5185\u4e3b\u7b4b\u4e0e\u6c34\u7535\u6697\u7ba1\uff0c\u5916\u5899\u5b54\u5411\u5916\u503e\u659c\u9632\u5012\u704c\uff1b\u6761\u6b3e34\u5f00\u69fd\uff1a\u4f18\u5148\u7ad6\u5411\uff0c\u627f\u91cd\u5899\u4e25\u7981\u6a2a\u5411\uff0c\u69fd\u6df1\u4e0d\u8d85\u5899\u539a1\/3\u3001\u52a0\u6c14\u5757\u4e0d\u8d8530mm\uff0c\u7ba1\u7ebf\u4fdd\u62a4\u5c42\u226515mm\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u5ba4\u5185\u673a\u5b89\u88c5\",\n      \"text\": \"\u6761\u6b3e3\u5185\u673a\u79bb\u5899\u2265100mm\u3001\u9876\u8ddd\u226510mm\uff1b\u6761\u6b3e4\u53cc\u87ba\u6bcd\u53cc\u51cf\u9707\u57ab\u6c34\u5e73\u56fa\u5b9a\uff1b\u6761\u6b3e5\u540a\u6746>1.5m\u52a0\u659c\u6491\uff1b\u6761\u6b3e6\u98ce\u53e3\u5bc6\u5c01\u9632\u5c18\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u5ba4\u5916\u673a\u5b89\u88c5\",\n      \"text\": \"\u6761\u6b3e7\u5b89\u88c5\u524d\u4e0d\u62c6\u5305\u88c5\uff1b\u6761\u6b3e8\u79bb\u5899\u2265200mm\u3001\u8fdc\u5367\u5ba4\uff1b\u6761\u6b3e9\u767e\u53f6\u901a\u98ce\u9762\u79ef\u226580%\uff1b\u6761\u6b3e11\u51cf\u9707\u57ab\u87ba\u6813\u56fa\u5b9a\uff1b\u6761\u6b3e12\u63a5\u6c34\u76d8\u9632\u6ef4\u6f0f\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u51b7\u5a92\u914d\u7ba1\u4e0e\u710a\u63a5\",\n      \"text\": \"\u6761\u6b3e13\u5e72\u71e5\u6e05\u6d01\u6c14\u5bc6\u4e09\u539f\u5219\uff1b\u6761\u6b3e14\u6c2e\u6c14\u4fdd\u62a4\u710a(\u6d41\u91cf\u22650.05m\u00b3\/h\u3001\u538b\u529b0.02-0.05MPa\u3001\u542b\u94f6\u22652%)\uff1b\u6761\u6b3e15\u5206\u6b67\u7ba1\u76f4\u7ba1\u6bb5\u2265500mm\uff1b\u6761\u6b3e16\u5206\u5c42\u72ec\u7acb\u56fa\u5b9a+PVC\u5957\u7ba1\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u7ba1\u8def\u7cfb\u7edf\",\n      \"text\": \"\u6761\u6b3e19\u652f\u540a\u67b60.8-1.0m\uff1b\u6761\u6b3e21\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22655\u2030\uff1b\u6761\u6b3e22\u8fd4\u6c34\u5f2f\u2264500mm\uff1b\u6761\u6b3e25\u901a\u6c14\u5b54+\u6392\u6c34\u5b9e\u9a8c\uff1b\u6761\u6b3e27\u4fdd\u6e29\u58c1\u539a\u8fbe\u6807\u65e0\u5f00\u88c2\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u7535\u6c14\u4e0e\u63a7\u5236\u5668\",\n      \"text\": \"\u6761\u6b3e28\u7535\u6e90\u901a\u8baf\u7ebf\u5355\u72ec\u7a7f\u7ba1\uff1b\u6761\u6b3e29\u7ebf\u63a7\u7aef\u5b50\u7edd\u7f18\u76d2\u76d6\u4fdd\u62a4\uff1b\u6761\u6b3e30\u63a7\u5236\u5668\u7262\u56fa\u6574\u9f50\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u6c14\u5bc6\u6027\u8bd5\u9a8c\u4e0e\u5236\u51b7\u5242\u8ffd\u52a0\",\n      \"text\": \"\u6761\u6b3e31\u5e72\u71e5\u6c2e\u6c14\u52a0\u538b\u81f34.15MPa(R410A)\u4fdd\u538b24h\u538b\u529b\u4e0d\u964d\u4e3a\u5408\u683c\uff0c\u5408\u683c\u540e\u964d\u81f31.5MPa\uff1b\u6761\u6b3e32\u5236\u51b7\u5242\u79f0\u91cd\u5145\u6ce8\u8bef\u5dee\u00b15g\u5185\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536\",\n      \"text\": \"\u6240\u6709\u8bbe\u5907\u6750\u6599\u4e0e\u5408\u540c\u914d\u7f6e\u6e05\u5355\u9010\u4e00\u6838\u5bf9\u54c1\u724c\u578b\u53f7\u89c4\u683c\u4e00\u81f4\uff0c\u5185\u673a\/\u5916\u673a\/\u94dc\u7ba1\/\u5206\u6b67\u7ba1\/\u51b7\u51dd\u6c34\u7ba1\/\u4fdd\u6e29\u68c9\/\u7ebf\u7ba1\/\u7535\u7f06\/\u8f85\u6750\u9010\u9879\u7b7e\u6536\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u98ce\u53e3\u4e0e\u7ebf\u63a7\u5668\u5b89\u88c5\",\n      \"text\": \"\u6761\u6b3e35\u88c5\u4fee\u5b8c\u5de5\u540e\u5b9e\u6d4b\u98ce\u53e3\u5f00\u5b54\u5c3a\u5bf8\u4ea4\u5de5\u5382\u5b9a\u5236\uff1b\u6761\u6b3e36\u8f6f\u8fde\u63a5\u5c55\u5f00\u94fa\u5e73\u4e0d\u76b1\u4e0d\u6f0f\u98ce\u3001\u957f\u5ea6100~200mm\u3001\u56de\u98ce\u53e3\u52a0\u8fc7\u6ee4\u7f51\uff1b\u6761\u6b3e37\u7ebf\u63a7\u5668\u7262\u56fa\u7aef\u6b63\u3001\u901a\u7535\u6d4b\u8bd5\u901a\u8baf\u6b63\u5e38\u3002\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"name\": \"\u7cfb\u7edf\u8c03\u8bd5\u3001\u8bd5\u8fd0\u884c\u4e0e\u7528\u6237\u4ea4\u4ed8\",\n      \"text\": \"\u6761\u6b3e38\u771f\u7a7a\u5e72\u71e5\u81f3-0.1MPa\u4fdd\u63012h\u6307\u9488\u4e0d\u56de\u5f39\uff1b\u6761\u6b3e39\u5236\u51b7\u5242\u79f0\u91cd\u8ffd\u52a0\u5e76\u6267\u884c\u5224\u5b9a\u8fd0\u884c\uff1b\u6761\u6b3e40\u8bd5\u8fd0\u884c\u22652\u5c0f\u65f6\u5e76\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u4f20\u611f\u5668\u6570\u636e\uff1b\u6761\u6b3e41\u5f53\u9762\u5411\u7528\u6237\u505a\u4f7f\u7528\u57f9\u8bad\u5e76\u4ea4\u4ed8\u4fdd\u4fee\u7535\u8bdd\u4e0e\u4fdd\u4fee\u671f\u3002\"\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u540e\u600e\u4e48\u9a8c\u6536\uff1f\u91cd\u70b9\u770b\u54ea\u4e9b\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5c01\u677f\u524d\u91cd\u70b9\u6838\u67e5\uff1a\u5185\u673a\u79bb\u5899\u2265100mm\u3001\u5916\u673a\u79bb\u5899\u2265200mm\uff1b\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u65e0\u6c27\u5316\u76ae\uff1b\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u22655\u2030\uff1b\u6c2e\u6c14\u4fdd\u538b 4.15MPa \u7ef4\u6301 24h \u538b\u529b\u4e0d\u964d\u3002\u5bf9\u7167\u672c\u9875\u5341\u4e00\u4e2a\u90e8\u5206\u9010\u9879\u786e\u8ba4\u5373\u53ef\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u4e3a\u4ec0\u4e48\u6253\u5b54\u8981\u907f\u5f00\u94a2\u7b4b\u3001\u5411\u5916\u503e\u659c\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u623f\u6881\u94a2\u7b4b\u591a\u5728\u4e24\u4fa7\uff0c\u6253\u9519\u4f1a\u7834\u574f\u627f\u91cd\u7ed3\u6784\uff1b\u5916\u5899\u5b54\u5411\u5916\u5899\u4fa7\u503e\u659c\u53ef\u9632\u6b62\u96e8\u6c34\u6cbf\u5b54\u5012\u704c\u8fdb\u5ba4\u5185\uff0c\u907f\u514d\u5899\u9762\u6e17\u6c34\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u6709\u4ec0\u4e48\u7528\uff1f\u4e0d\u505a\u4f1a\u600e\u6837\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u710a\u63a5\u65f6\u901a\u6c2e\u6c14\u7f6e\u6362\u7ba1\u5185\u7a7a\u6c14\uff0c\u9632\u6b62\u94dc\u7ba1\u5185\u58c1\u751f\u6210\u6c27\u5316\u76ae\u3002\u4e0d\u505a\u5219\u6c27\u5316\u76ae\u968f\u51b7\u5a92\u5faa\u73af\uff0c\u6613\u5835\u585e\u7535\u5b50\u81a8\u80c0\u9600\u3001\u78e8\u635f\u538b\u7f29\u673a\uff0c\u5bfc\u81f4\u7a7a\u8c03\u762b\u75ea\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6c14\u5bc6\u6027\u8bd5\u9a8c\u4e3a\u4ec0\u4e48\u8981\u4fdd\u538b 24 \u5c0f\u65f6\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"4.15MPa \u4fdd\u538b 24h \u662f\u9a8c\u8bc1\u5168\u90e8\u94dc\u7ba1\u63a5\u5934\u65e0\u6cc4\u6f0f\u7684\u6700\u7ec8\u624b\u6bb5\uff0c\u4e5f\u662f\u9690\u853d\u5de5\u7a0b\u6700\u5173\u952e\u9a8c\u6536\u8282\u70b9\u3002\u5408\u683c\u540e\u624d\u653e\u5fc3\u5c01\u677f\uff0c\u907f\u514d\u540e\u671f\u6316\u540a\u9876\u8fd4\u5de5\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5899\u9762\u5f00\u69fd\u6709\u4ec0\u4e48\u8bb2\u7a76\uff1f\u627f\u91cd\u5899\u80fd\u5f00\u69fd\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4f18\u5148\u7ad6\u5411\u5f00\u69fd\uff0c\u627f\u91cd\u5899\u4e25\u7981\u6a2a\u5411\u5f00\u69fd\u3002\u5f00\u69fd\u6df1\u5ea6\u4e0d\u5927\u4e8e\u5899\u539a\u7684 1\/3\uff0c\u52a0\u6c14\u5757\u5899\u4f53\u4e0d\u5927\u4e8e 30mm\uff1b\u69fd\u6df1\u4e3a\u7ba1\u5916\u5f84\u52a0 10~20mm\uff0c\u69fd\u5bbd\u4e3a\u7ba1\u5916\u5f84\u52a0 30~60mm\uff0c\u7ba1\u7ebf\u6577\u8bbe\u540e\u8868\u9762\u7802\u6d46\u4fdd\u62a4\u5c42\u4e0d\u5c0f\u4e8e 15mm\u3002\u8981\u7528\u4e13\u7528\u5f00\u69fd\u673a\u5207\u5272\uff0c\u4e0d\u80fd\u7528\u7535\u9524\u6216\u5927\u9524\u968f\u610f\u5254\u51ff\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u88c5\u5b8c\u62bd\u771f\u7a7a\u8981\u591a\u4e45\uff1f\u600e\u4e48\u7b97\u5408\u683c\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u771f\u7a7a\u5ea6\u8981\u62bd\u5230 -0.1MPa\uff08-755mmHg\uff09\u4ee5\u4e0b\uff0c\u4fdd\u6301 2 \u5c0f\u65f6\u4ee5\u4e0a\uff0c\u5173\u6cf5\u540e\u6307\u9488\u4e0d\u56de\u5f39\uff0c\u624d\u7b97\u5408\u683c\u3002\u62bd\u771f\u7a7a\u662f\u4e3a\u4e86\u6392\u6389\u7ba1\u8def\u91cc\u7684\u7a7a\u6c14\u548c\u6c34\u5206\uff0c\u4e0d\u8fbe\u6807\u4f1a\u5bfc\u81f4\u51b0\u5835\u3001\u6c27\u5316\uff0c\u751a\u81f3\u635f\u574f\u538b\u7f29\u673a\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u98ce\u53e3\u4ec0\u4e48\u65f6\u5019\u91cf\u3001\u4ec0\u4e48\u65f6\u5019\u88c5\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u540a\u9876\u3001\u5899\u9762\u3001\u67dc\u4f53\u88c5\u4fee\u57fa\u672c\u5b8c\u5de5\u540e\uff0c\u518d\u73b0\u573a\u5b9e\u6d4b\u51fa\u98ce\u53e3\u3001\u56de\u98ce\u53e3\u7684\u5b9e\u9645\u5f00\u5b54\u5c3a\u5bf8\uff0c\u4ea4\u5de5\u5382\u5b9a\u5236\uff1b\u98ce\u53e3\u9762\u677f\u5230\u8d27\u540e\u518d\u5b89\u88c5\u3002\u8f6f\u8fde\u63a5\u8981\u5c55\u5f00\u94fa\u5e73\uff0c\u8fde\u63a5\u4e25\u5bc6\u3001\u4e0d\u8936\u76b1\u3001\u4e0d\u6f0f\u98ce\uff0c\u957f\u5ea6\u63a7\u5236\u5728 100~200mm\uff1b\u56de\u98ce\u53e3\u8981\u540c\u6b65\u88c5\u8fc7\u6ee4\u7f51\uff0c\u65b9\u4fbf\u540e\u671f\u62c6\u6d17\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u4e2d\u592e\u7a7a\u8c03\u88c5\u5b8c\u600e\u4e48\u8bd5\u673a\uff1f\u4ea4\u4ed8\u65f6\u7ed9\u4ec0\u4e48\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u7531\u8c03\u8bd5\u4eba\u5458\u5f00\u673a\u8bd5\u8fd0\u884c\u4e0d\u5c11\u4e8e 2 \u5c0f\u65f6\uff0c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u5404\u9879\u4f20\u611f\u5668\u6570\u636e\u786e\u8ba4\u6b63\u5e38\uff1b\u7136\u540e\u5f53\u9762\u5411\u7528\u6237\u505a\u4f7f\u7528\u57f9\u8bad\uff0c\u4ea4\u4ed8\u4ea7\u54c1\u4f7f\u7528\u65b9\u6cd5\u3001\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\u3001\u624b\u673a APP\u3001\u7ebf\u63a7\u5668\u4e8c\u7ef4\u7801\u3001\u4fdd\u4fee\u7535\u8bdd\u3001\u4fdd\u4fee\u671f\u548c\u4fdd\u517b\u5e38\u8bc6\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"HomeAndConstructionBusiness\",\n  \"name\": \"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"description\": \"\u6210\u90fd\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u4e2d\u592e\u7a7a\u8c03\/\u5730\u6696\/\u6696\u6c14\u7247\/\u4e24\u8054\u4f9b\/\u4e94\u6052\u7cfb\u7edf\u4e0a\u95e8\u52d8\u6d4b\u8bbe\u8ba1\u5b89\u88c5\uff0c\u5357\u5bcc\u68ee+\u5317\u5bcc\u68ee\u53cc\u5b9e\u4f53\u5c55\u5385\",\n  \"telephone\": [\n    \"028-86131795\",\n    \"028-65272586\"\n  ],\n  \"image\": [\n    \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\n    \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\"\n  ],\n  \"address\": {\n    \"@type\": \"PostalAddress\",\n    \"streetAddress\": \"\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\n    \"addressLocality\": \"\u9ad8\u65b0\u533a\",\n    \"addressRegion\": \"\u6210\u90fd\u5e02\"\n  },\n  \"areaServed\": [\n    \"\u9ad8\u65b0\u533a\",\n    \"\u53cc\u6d41\u533a\",\n    \"\u90eb\u90fd\u533a\",\n    \"\u9f99\u6cc9\u9a7f\",\n    \"\u5929\u5e9c\u65b0\u533a\",\n    \"\u9752\u7f8a\u533a\",\n    \"\u6210\u534e\u533a\",\n    \"\u65b0\u90fd\u533a\",\n    \"\u89c6\u9ad8\"\n  ],\n  \"openingHours\": \"09:00-18:00\",\n  \"sameAs\": \"https:\/\/longmai-nt.com\",\n  \"hasMap\": [\n    \"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&city=510107&geoobj=104.05892|30.598786|104.074284|30.605656&query_type=IDQ&query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)&zoom=17\",\n    \"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&city=510108&geoobj=104.059547|30.599807|104.07041|30.604665&query_type=IDQ&query=\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986(\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97)&zoom=17.5\"\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u6210 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-11380","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6e05\u5355\uff0c\u5185\u673a\u3001\u5916\u673a\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u538b\u6d4b\u8bd5\u3001\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\uff0c\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u81ea\u67e5\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u8ba4\u8bc1\u5b89\u88c5\u5546\uff0c2004\u5e74\u8d77\u4e13\u6ce8\u4e8e\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7528\u6237\u8282\u80fd\u3001\u8212\u9002\u3001\u7a33\u5b9a\u8bbe\u8ba1\u4e0e\u5b89\u88c5\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=11380\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6e05\u5355\uff0c\u5185\u673a\u3001\u5916\u673a\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u538b\u6d4b\u8bd5\u3001\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\uff0c\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u81ea\u67e5\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u8ba4\u8bc1\u5b89\u88c5\u5546\uff0c2004\u5e74\u8d77\u4e13\u6ce8\u4e8e\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7528\u6237\u8282\u80fd\u3001\u8212\u9002\u3001\u7a33\u5b9a\u8bbe\u8ba1\u4e0e\u5b89\u88c5\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=11380\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-21T05:56:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380\",\"name\":\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"datePublished\":\"2026-08-23T17:17:30+00:00\",\"dateModified\":\"2026-10-21T05:56:50+00:00\",\"description\":\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6e05\u5355\uff0c\u5185\u673a\u3001\u5916\u673a\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u538b\u6d4b\u8bd5\u3001\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\uff0c\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u81ea\u67e5\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u8ba4\u8bc1\u5b89\u88c5\u5546\uff0c2004\u5e74\u8d77\u4e13\u6ce8\u4e8e\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7528\u6237\u8282\u80fd\u3001\u8212\u9002\u3001\u7a33\u5b9a\u8bbe\u8ba1\u4e0e\u5b89\u88c5\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-dljkdsgpmt.jpg\",\"width\":1754,\"height\":1240},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11380#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6e05\u5355\uff0c\u5185\u673a\u3001\u5916\u673a\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u538b\u6d4b\u8bd5\u3001\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\uff0c\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u81ea\u67e5\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u8ba4\u8bc1\u5b89\u88c5\u5546\uff0c2004\u5e74\u8d77\u4e13\u6ce8\u4e8e\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7528\u6237\u8282\u80fd\u3001\u8212\u9002\u3001\u7a33\u5b9a\u8bbe\u8ba1\u4e0e\u5b89\u88c5\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=11380","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6e05\u5355\uff0c\u5185\u673a\u3001\u5916\u673a\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u538b\u6d4b\u8bd5\u3001\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\uff0c\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u81ea\u67e5\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u8ba4\u8bc1\u5b89\u88c5\u5546\uff0c2004\u5e74\u8d77\u4e13\u6ce8\u4e8e\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7528\u6237\u8282\u80fd\u3001\u8212\u9002\u3001\u7a33\u5b9a\u8bbe\u8ba1\u4e0e\u5b89\u88c5\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=11380","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-21T05:56:50+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=11380","url":"https:\/\/longmai-nt.com\/?page_id=11380","name":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=11380#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=11380#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","datePublished":"2026-08-23T17:17:30+00:00","dateModified":"2026-10-21T05:56:50+00:00","description":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6e05\u5355\uff0c\u5185\u673a\u3001\u5916\u673a\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u538b\u6d4b\u8bd5\u3001\u51b7\u51dd\u6c34\u7ba1\u89c4\u8303\uff0c\u88c5\u4fee\u5c01\u677f\u524d\u5bf9\u7167\u81ea\u67e5\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u8ba4\u8bc1\u5b89\u88c5\u5546\uff0c2004\u5e74\u8d77\u4e13\u6ce8\u4e8e\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u7528\u6237\u8282\u80fd\u3001\u8212\u9002\u3001\u7a33\u5b9a\u8bbe\u8ba1\u4e0e\u5b89\u88c5\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=11380#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=11380"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=11380#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dljkdsgpmt.jpg","width":1754,"height":1240},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=11380#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff5c\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u5b89\u88c5\u89c4\u8303"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11380"}],"version-history":[{"count":13,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11380\/revisions"}],"predecessor-version":[{"id":15884,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11380\/revisions\/15884"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}