{"id":11713,"date":"2026-08-27T13:57:25","date_gmt":"2026-08-27T05:57:25","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=11713"},"modified":"2026-10-13T23:20:08","modified_gmt":"2026-10-13T15:20:08","slug":"%e6%88%90%e9%83%bd%e9%87%91%e7%89%9b%e5%8c%ba%e9%be%99%e6%b9%96%e6%ba%90%e8%91%97%e4%b8%9c%e5%8c%ba90%e3%8e%a1%e5%a5%97%e4%b8%89-%c2%b7-%e6%b1%a4%e5%85%88%e7%94%9f%e6%97%a5%e7%ab%8b%e6%b0%b4%e5%a2%85","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=11713","title":{"rendered":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f"},"content":{"rendered":"\n\n<style>\n  :root{\n    --lm-brand:#1f6b78; --lm-brand-d:#154e58; --lm-accent:#e89440; --lm-accent-d:#c97a26;\n    --lm-ink:#222; --lm-txt:#333; --lm-txt-lt:#666; --lm-bd:#e3e8ea; --lm-bg:#f7f9fa;\n    --lm-warm-bg:#fdf3e7; --lm-red:#c0392b; --lm-green:#2e8b57;\n  }\n  *{box-sizing:border-box}\n  html{scroll-behavior:smooth}\n  body{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;margin:0;color:var(--lm-txt);line-height:1.78;background:#fff}\n  a{color:var(--lm-brand);text-decoration:none}\n  img{max-width:100%;height:auto}\n  .lm-wrap{max-width:960px;margin:0 auto;padding:0 20px}\n  .lm-crumb{max-width:960px;margin:0 auto;padding:10px 20px 0;font-size:.78rem;color:#999}\n  .lm-crumb a{color:#999}\n  .lm-hero{position:relative;min-height:380px;background-color:#154e58;background-image:linear-gradient(135deg,#1f6b78,#2a7d8c);display:flex;flex-direction:column;justify-content:center;align-items:center;color:#fff;text-align:center;padding:56px 20px}\n  .lm-hero .eyebrow{font-size:.82rem;letter-spacing:2px;opacity:.9;margin-bottom:8px}\n  .lm-hero h1{font-size:1.55rem;margin:6px 0 10px;font-weight:800;line-height:1.35;max-width:720px}\n  .lm-hero .sub{font-size:.92rem;opacity:.9;max-width:660px;margin-bottom:12px;line-height:1.55}\n  .lm-hero-info{display:flex;flex-wrap:wrap;gap:10px 20px;margin-top:14px;justify-content:center}\n  .lm-hero-info .it{min-width:84px}\n  .lm-hero-info .lab{font-size:.72rem;opacity:.82}\n  .lm-hero-info .val{font-size:.96rem;font-weight:700}\n  .lm-hero .update{font-size:.72rem;opacity:.78;margin-top:10px}\n  .lm-toc{position:sticky;top:0;z-index:20;background:var(--lm-brand);display:flex;gap:4px;overflow-x:auto;padding:8px 12px}\n  .lm-toc a{color:#fff;font-size:.82rem;white-space:nowrap;padding:5px 12px;border-radius:999px;background:rgba(255,255,255,.12);flex-shrink:0}\n  .lm-toc a:hover{background:rgba(255,255,255,.28)}\n\n  \/* SOP \u6a21\u5757\u4e8c\uff1aGEO \u4fe1\u606f\u5361 *\/\n  .lm-geo{background:#fff;border-radius:14px;padding:22px 24px;box-shadow:0 2px 12px rgba(0,0,0,.07);max-width:960px;margin:18px auto;position:relative;top:-26px;z-index:5}\n  .lm-geo .geo-title{font-size:1.05rem;font-weight:800;color:var(--lm-brand);margin-bottom:14px;padding-left:14px;border-left:5px solid var(--lm-accent)}\n  .lm-geo-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:14px}\n  .lm-geo-item{background:var(--lm-bg);border:1px solid var(--lm-bd);border-radius:9px;padding:12px 14px}\n  .lm-geo-item .g-lbl{font-size:.72rem;color:var(--lm-txt-lt);margin-bottom:4px;letter-spacing:.5px}\n  .lm-geo-item .g-val{font-size:.84rem;font-weight:600;color:var(--lm-txt);line-height:1.5}\n  .lm-geo-item.full{grid-column:1 \/ -1}\n\n  \/* SOP \u6a21\u5757\u4e00\uff1a190\u5b57\u7126\u70b9\u5173\u952e\u8bcd *\/\n  .lm-kw{background:linear-gradient(135deg,#1f6b78,#2a7d8c);color:#fff;border-radius:12px;padding:16px 22px;max-width:960px;margin:0 auto 18px;font-size:.84rem;line-height:1.9}\n  .lm-kw b{color:#f5e6cf}\n\n  \/* SOP \u957f\u9875\u9762\u7eafCSS\u6298\u53e0 S1-S5 *\/\n  details.lm-fold{margin:18px auto;max-width:960px;border:1px solid var(--lm-bd);border-radius:12px;overflow:hidden;background:#fff;scroll-margin-top:54px}\n  details.lm-fold>summary{cursor:pointer;list-style:none;padding:16px 22px;background:linear-gradient(135deg,#1f6b78,#2a7d8c);color:#fff;font-weight:800;display:flex;align-items:center;gap:10px}\n  details.lm-fold>summary::-webkit-details-marker{display:none}\n  details.lm-fold>summary h2{margin:0;color:#fff;font-size:1.14rem;font-weight:800;display:inline}\n  details.lm-fold>summary .fold-ico{margin-left:auto;font-size:1.1rem;opacity:.9}\n  .lm-fold-body{padding:6px 22px 22px}\n\n  h3{color:var(--lm-brand-d);font-size:1.04rem;margin:22px 0 10px;padding-left:11px;border-left:4px solid var(--lm-accent)}\n  table{border-collapse:collapse;width:100%;margin:12px 0;font-size:.87rem}\n  th,td{border:1px solid #d9e2e5;padding:9px 11px;text-align:left;vertical-align:top}\n  th{background:#eaf2f4;color:var(--lm-brand-d);font-weight:700}\n  tr:nth-child(even) td{background:#fafcfd}\n  .lm-card{background:var(--lm-warm-bg);border:1px solid #f0d9b8;border-radius:10px;padding:14px 18px;margin:12px 0;font-size:.9rem;line-height:1.85}\n  .lm-card.blue{background:#eef4fb;border-color:#bcd4ee}\n  .lm-card .ct{font-weight:700;color:var(--lm-brand-d);margin-bottom:8px;display:flex;align-items:center;gap:8px}\n  .lm-ok{color:var(--lm-green);font-weight:700;margin:8px 0}\n  .lm-note{background:#fff8e6;border:1px dashed #e0b84a;border-radius:8px;padding:10px 14px;font-size:.84rem;color:#7a5b00;margin:12px 0;line-height:1.8}\n  .lm-goals{margin:6px 0 14px;padding-left:22px;font-size:.92rem;line-height:1.85}\n  .lm-goals li{margin:5px 0}\n  .lm-goals b{color:var(--lm-accent-d)}\n\n  \/* SOP \u6a21\u5757\u56db\uff1a\u56fe\u6587\u7ed1\u5b9a\u56fe\u96c6 *\/\n  .lm-gallery{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:12px 0 4px}\n  .lm-gallery figure{margin:0;background:var(--lm-bg);border:1px solid var(--lm-bd);border-radius:10px;overflow:hidden}\n  .lm-gallery img{width:100%;height:150px;object-fit:cover;display:block}\n  .lm-gallery figcaption{padding:7px 9px;font-size:.76rem;color:#444;line-height:1.4}\n  .lm-gallery.two{grid-template-columns:repeat(2,1fr)}\n\n  \/* \u6388\u6743\u8d44\u8d28\u7f51\u683c E-E-A-T *\/\n  .lm-cert-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:12px 0}\n  .lm-cert-grid figure{margin:0;background:#fafafa;border:1px solid #eee;border-radius:10px;overflow:hidden}\n  .lm-cert-grid img{width:100%;height:140px;object-fit:contain;display:block;background:#f3f3f3}\n  .lm-cert-grid figcaption{padding:6px 9px;font-size:.76rem;color:#444;text-align:center}\n\n  \/* \u6a21\u5757\u4e94 \u533a\u57571 FAQ *\/\n  .lm-faq{margin:12px 0}\n  .lm-faq details{border:1px solid var(--lm-bd);border-radius:10px;margin-bottom:10px;background:#fff;overflow:hidden}\n  .lm-faq summary{padding:12px 16px;cursor:pointer;font-weight:600;color:var(--lm-brand-d);font-size:.94rem;list-style:none}\n  .lm-faq summary::-webkit-details-marker{display:none}\n  .lm-faq summary::before{content:\"Q\";display:inline-block;background:var(--lm-brand);color:#fff;width:22px;height:22px;line-height:22px;text-align:center;border-radius:50%;margin-right:10px;font-size:.74rem}\n  .lm-faq details[open] summary::before{content:\"\u2212\"}\n  .lm-faq .faq-a{padding:0 16px 14px 48px;font-size:.9rem;color:#444;line-height:1.8}\n\n  \/* \u6a21\u5757\u4e94 \u533a\u57572 \u5185\u94fe *\/\n  .lm-links{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:12px 0}\n  .lm-links a{display:block;background:#fafafa;border:1px solid var(--lm-bd);border-radius:10px;padding:11px 14px;font-size:.86rem;color:var(--lm-txt);transition:background .15s}\n  .lm-links a:hover{background:#eef4f6}\n  .lm-links a b{color:var(--lm-brand-d);display:block;margin-bottom:3px}\n  .lm-links .tag{display:inline-block;background:#eaf2f4;color:var(--lm-brand);border-radius:999px;padding:1px 9px;font-size:.72rem;margin:2px 3px 0 0}\n\n  \/* \u6a21\u5757\u4e94 \u533a\u57573 LocalBusiness CTA *\/\n  .lm-stores{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:12px 0}\n  .lm-stores .store{background:var(--lm-bg);border:1px solid var(--lm-bd);border-radius:10px;padding:14px;font-size:.86rem;line-height:1.7}\n  .lm-stores .st-name{font-weight:700;color:var(--lm-brand-d);margin-bottom:4px}\n  .lm-cta-box{background:linear-gradient(135deg,#fdf3e7,#fbeede);border:1px solid #f0d9b8;border-radius:12px;padding:16px 18px;margin:14px 0;font-size:.88rem;line-height:1.85}\n  .lm-cta-box b{color:var(--lm-accent-d)}\n\n  .lm-foot{max-width:960px;margin:22px auto;padding:16px 20px;font-size:.8rem;color:#888;border-top:1px solid #eee;line-height:1.7}\n  .lm-section-h2{max-width:960px;margin:26px auto 4px;padding:0 20px}\n  .lm-section-h2 h2{color:var(--lm-brand);font-size:1.18rem;margin:0;padding-left:12px;border-left:5px solid var(--lm-accent);line-height:1.5}\n  @media(max-width:768px){.lm-geo-grid{grid-template-columns:repeat(2,1fr)}.lm-gallery,.lm-cert-grid,.lm-links,.lm-stores{grid-template-columns:1fr}}\n<\/style>\n\n<nav class=\"lm-crumb\"><a href=\"https:\/\/longmai-nt.com\" target=\"_blank\">\u9f99\u8109\u6696\u901a<\/a> \u203a <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\">\u5ba2\u6237\u6848\u4f8b\u5e93<\/a> \u203a \u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u00b7 \u6c64\u5148\u751f \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b8c\u5de5\u6848\u4f8b<\/nav>\n\n<div class=\"lm-hero\">\n  <div class=\"eyebrow\">\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b \u00b7 \u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b \u00b7 \u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf \u00b7 \u6210\u90fd\u91d1\u725b\u533a<\/div>\n  <h2>\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f<\/h2>\n  <div class=\"sub\">\u6838\u5fc3\u76ee\u6807\uff1a\u544a\u522b\u6c1f\u673a\u51b0\u98ce\u523a\u9aa8\u3001\u51fa\u98ce\u67d4\u548c\u4e0d\u5e72\u71e5\u3001\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3001\u4e00\u5957\u4e3b\u673a\u5168\u5c4b\u51b7\u6696\u3002RAS-160\u5168\u53d8\u9891\u4e3b\u673a + \u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf + 5\u53f0\u96f6\u8d8a\u98ce\u76d8\u5206\u533a\u63a7\u6e29\uff0c\u4e3b\u6253\u6c34\u7cfb\u7edf\u67d4\u98ce\u4e0e\u514d\u6c34\u7bb1\u9ad8\u6548\u7b80\u6d01\u3002<\/div>\n  <div class=\"lm-hero-info\">\n    <div class=\"it\"><div class=\"lab\">\u5957\u5185\u9762\u79ef<\/div><div class=\"val\">\u7ea6 90\u33a1<\/div><\/div>\n    <div class=\"it\"><div class=\"lab\">\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"val\">\u7ea6 80\u33a1<\/div><\/div>\n    <div class=\"it\"><div class=\"lab\">\u91c7\u6696\u9762\u79ef<\/div><div class=\"val\">\u7ea6 77\u33a1<\/div><\/div>\n    <div class=\"it\"><div class=\"lab\">\u7cfb\u7edf\u5f62\u5f0f<\/div><div class=\"val\">\u6c34\u5885\u9002\u4e24\u8054\u4f9b<\/div><\/div>\n    <div class=\"it\"><div class=\"lab\">\u4e3b\u673a<\/div><div class=\"val\">RAS-160 7\u5339<\/div><\/div>\n  <\/div>\n  <div class=\"update\">\u6848\u4f8b\u987e\u95ee\uff1a\u5f90\u65b0\u5e73 \ud83d\udcde 18227055065\uff08\u9f99\u8109\u6696\u901a\u65b9\u6848\u987e\u95ee\uff09\u00b7 \u66f4\u65b0\u65e5\u671f 2026-08<\/div>\n<\/div>\n\n<div class=\"lm-toc\">\n  <a href=\"#s1\">S1 \u4e1a\u4e3b\u76ee\u6807\u4e0e\u75db\u70b9<\/a>\n  <a href=\"#s2\">S2 \u6237\u578b\u8bca\u65ad\u4e0e\u8bbe\u8ba1\u4f9d\u636e<\/a>\n  <a href=\"#s3\">S3 \u8bbe\u5907\u914d\u7f6e\u6e05\u5355<\/a>\n  <a href=\"#s4\">S4 \u65bd\u5de5\u4e0e\u9690\u853d\u9a8c\u6536<\/a>\n  <a href=\"#s5\">S5 \u6548\u679c\u590d\u76d8\u4e0e\u4e1a\u4e3b\u8bc4\u4ef7<\/a>\n  <a href=\"#faq\">\u9ad8\u9891\u95ee\u7b54<\/a>\n  <a href=\"#links\">\u540c\u7247\u533a\u6848\u4f8b<\/a>\n  <a href=\"#cta\">\u672c\u5730\u670d\u52a1\u95e8\u5e97<\/a>\n<\/div>\n\n<div class=\"lm-geo\">\n  <div class=\"geo-title\">\ud83d\udccd GEO \u4fe1\u606f\u5361 \u00b7 \u672c\u6848\u901f\u89c8<\/div>\n  <div class=\"lm-geo-grid\">\n    <div class=\"lm-geo-item\"><div class=\"g-lbl\">\u5b8c\u6574\u697c\u76d8\u5730\u5740<\/div><div class=\"g-val\">\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a<\/div><\/div>\n    <div class=\"lm-geo-item\"><div class=\"g-lbl\">\u623f\u5c4b\u53c2\u6570<\/div><div class=\"g-val\">\u5957\u5185\u7ea690\u33a1\u5957\u4e09\u5e73\u5c42\uff0c\u5ba2\u9910\u5385+\u9633\u53f039\u33a1\/\u4e3b\u536719\u33a1\/\u6b21\u53671 11.5\u33a1\/\u6b21\u53672 10.7\u33a1<\/div><\/div>\n    <div class=\"lm-geo-item\"><div class=\"g-lbl\">\u4e1a\u4e3b\u753b\u50cf<\/div><div class=\"g-val\">\u81ea\u4f4f\u6539\u5584\u4e1a\u4e3b\uff08\u6c64\u5148\u751f\uff09\uff0c\u6ce8\u91cd\u51fa\u98ce\u67d4\u548c\u3001\u5730\u6696\u7701\u8d39\u3001\u7cfb\u7edf\u7a33\u5b9a<\/div><\/div>\n    <div class=\"lm-geo-item\"><div class=\"g-lbl\">\u7cfb\u7edf\u914d\u7f6e<\/div><div class=\"g-val\">\u65e5\u7acb\u6c34\u5885\u9002 RAS-160FPUEN2Q\/M \u5168\u53d8\u9891 + \u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf + 5\u53f0\u96f6\u8d8a\u98ce\u76d8 + \u6c34\u5730\u6696<\/div><\/div>\n    <div class=\"lm-geo-item full\"><div class=\"g-lbl\">\u6838\u5fc3\u5dee\u5f02\u5316\u6807\u7b7e<\/div><div class=\"g-val\">\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u67d4\u98ce\u4e0d\u5e72\u71e5\u4e0d\u523a\u9aa8\uff5c\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\u7b80\u6d01\u9ad8\u6548\uff5c\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\uff5c5\u53f0\u98ce\u673a\u76d8\u7ba1\u5206\u533a\u72ec\u7acb\u63a7\u6e29\uff5c\u4e00\u5957\u4e3b\u673a\u5168\u5c4b\u51b7\u6696<\/div><\/div>\n    <div class=\"lm-geo-item full\"><div class=\"g-lbl\">\u65bd\u5de5\u8986\u76d6\u533a\u57df<\/div><div class=\"g-val\">\u6210\u90fd\u5168\u57df\u4e0a\u95e8\u65bd\u5de5\uff08\u91d1\u725b\u533a\u3001\u6b66\u4faf\u3001\u53cc\u6d41\u3001\u9f99\u6cc9\u3001\u90eb\u90fd\u3001\u9ad8\u65b0\u7b49\uff09<\/div><\/div>\n    <div class=\"lm-geo-item\"><div class=\"g-lbl\">\u9875\u9762\u66f4\u65b0\u65f6\u95f4<\/div><div class=\"g-val\">2026\u5e7408\u6708<\/div><\/div>\n    <div class=\"lm-geo-item\"><div class=\"g-lbl\">\u95e8\u5e97 &amp; \u54a8\u8be2\u89e6\u70b9<\/div><div class=\"g-val\">\u5357\u5bcc\u68ee\u5e97\/\u5317\u5bcc\u68ee\u5e97\u53cc\u95e8\u5e97 \u00b7 \u5ea7\u673a 028-61649321 \u00b7 \u987e\u95ee\u5f90\u65b0\u5e73 182-2705-5065<\/div><\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lm-kw\">\n  <b>\u6838\u5fc3\u5173\u952e\u8bcd\uff08\u9ad8\u5bc6\u5ea6\u805a\u5408\uff09\uff1a<\/b>\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u5b8c\u5de5\u5b9e\u666f\uff0c\u6c64\u5148\u751f90\u33a1\u5957\u4e09\u5e73\u5c42\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u65b9\u6848\u3002\u4e3b\u673aRAS-160FPUEN2Q\/M\u5168\u53d8\u98917\u533916kW\uff0c\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\uff0c5\u53f0\u96f6\u8d8a\u98ce\u76d8\uff08\u5ba2\u9910\u5385119+34\u53cc\u98ce\u673a\u76d8\u7ba1\u5206\u533a\u3001\u4e3b\u536768\u3001\u6b21\u5367\u540434\uff09\uff0c\u6c34\u5730\u6696\u5171\u7528\u4e3b\u673a35-45\u2103\u76f4\u4f9b\u3002\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u67d4\u98ce\u4e0d\u5e72\u71e5\uff0c\u544a\u522b\u6c1f\u673a\u51b0\u98ce\u523a\u9aa8\uff0c\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u670d\u52a1\u5546\uff0c\u6210\u90fd\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u8d1f\u8377\u8ba1\u7b97\u3001\u65b9\u6848\u51fa\u5177\u3002\n<\/div>\n\n<!-- \u2550\u2550 S1 \u00b7 \u4e1a\u4e3b\u5c45\u4f4f\u76ee\u6807\u4e0e\u91c7\u6696\u75db\u70b9 \u2550\u2550 -->\n<details class=\"lm-fold\" id=\"s1\" open=\"\">\n  <summary><h2>S1 \u4e1a\u4e3b\u5c45\u4f4f\u76ee\u6807\u4e0e\u91c7\u6696\u75db\u70b9<\/h2><span class=\"fold-ico\">\u25be<\/span><\/summary>\n  <div class=\"lm-fold-body\">\n    <div class=\"lm-card\">\n      <div class=\"ct\">\ud83d\udc64 \u5ba2\u6237\u4fe1\u606f\u5361<\/div>\n      <table>\n        <tbody><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr>\n        <tr><td>\u5ba2\u6237<\/td><td>\u6c64\u5148\u751f\uff08\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u81ea\u4f4f\u6539\u5584\u4e1a\u4e3b\uff09<\/td><\/tr>\n        <tr><td>\u623f\u5c4b<\/td><td>\u5957\u5185\u7ea690\u33a1\uff0c\u7a7a\u8c03\u9762\u79ef\u7ea680\u33a1\uff0c\u5ba2\u9910\u5385+\u9633\u53f0+\u4e3b\u5367+\u6b21\u53671+\u6b21\u53672<\/td><\/tr>\n        <tr><td>\u6838\u5fc3\u8bc9\u6c42<\/td><td>\u5439\u5b8c\u6c1f\u673a\u7a7a\u8c03\u5f88\u4e0d\u8212\u670d\u3001\u5168\u5c4b\u8212\u9002\u51b7\u6696\u3001\u51fa\u98ce\u67d4\u548c\u3001\u5730\u6696\u7701\u8d39<\/td><\/tr>\n        <tr><td>\u9009\u578b\u503e\u5411<\/td><td>\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u2014\u2014\u6c34\u7cfb\u7edf\u51fa\u98ce\u67d4\u548c\uff0c\u544a\u522b\u6c1f\u673a\u51b0\u98ce\u523a\u9aa8<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <h3>\u75db\u70b9 \u2192 \u6210\u90fd\u672c\u5730\u6c14\u5019\u7ed1\u5b9a<\/h3>\n    <div class=\"lm-card blue\">\n      <p style=\"margin:0 0 8px\">\u6210\u90fd\u5c5e<b>\u590f\u70ed\u51ac\u51b7\u3001\u51ac\u5b63\u9ad8\u6e7f<\/b>\u6c14\u5019\uff1a\u51ac\u5b63\u6e7f\u51b7\u4f53\u611f\u6e29\u5ea6\u4f4e\u3001\u7a7a\u8c03\u623f\u5e72\u71e5\u5f15\u8d77\u54bd\u5589\u4e0d\u9002\uff1b\u6c64\u5148\u751f\u6b64\u524d\u4f7f\u7528\u6c1f\u673a\u7a7a\u8c03\uff0c<b>\u51fa\u98ce7-12\u2103\u53c8\u51b7\u53c8\u5e72<\/b>\uff0c\u5439\u4e45\u5934\u75bc\u53e3\u5e72\uff0c\u660e\u786e\"\u5439\u5b8c\u6c1f\u673a\u5f88\u4e0d\u8212\u670d\"\u3002\u672c\u6848\u6838\u5fc3\u5c31\u662f\u7528\u6c34\u7cfb\u7edf\u67d4\u98ce\u89e3\u51b3\u8fd9\u4e00\u4f53\u611f\u75db\u70b9\u3002<\/p>\n    <\/div>\n    <table>\n      <tbody><tr><th>\u5ba2\u6237\u8bf4\u7684<\/th><th>\u80cc\u540e\u7684\u6280\u672f\u672c\u8d28<\/th><th>\u8bca\u65ad\u7ed3\u8bba<\/th><th>\u8bbe\u8ba1\u56de\u5e94<\/th><\/tr>\n      <tr><td>\u5439\u5b8c\u6c1f\u673a\u7a7a\u8c03\u5f88\u4e0d\u8212\u670d<\/td><td>\u6c1f\u673a\u51fa\u98ce7-12\u2103\u51b7\u98ce\u76f4\u5439\u3001\u5ba4\u5185\u5e72\u71e5<\/td><td>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u6070\u597d\u89e3\u51b3<\/td><td>\u6c34\u5885\u9002\u4e24\u8054\u4f9b + \u96f6\u8d8a\u98ce\u76d8\u67d4\u98ce<\/td><\/tr>\n      <tr><td>\u8981\u5168\u5c4b\u51c9\u5feb\u6696\u548c<\/td><td>\u9700\u5206\u533a\u72ec\u7acb\u63a7\u6e29\uff0c\u5ba2\u9910\u5385\u5927\u7a7a\u95f4\u9700\u5927\u5bb9\u91cf\u98ce\u673a\u76d8\u7ba1<\/td><td>\u5ba2\u9910\u538539\u33a1\u914d\u53cc\u98ce\u673a\u76d8\u7ba1\u3001\u4e3b\u5367\u6b21\u5367\u72ec\u7acb\u6e29\u63a7<\/td><td>\u5ba2\u9910\u5385119+34\u53cc\u98ce\u673a\u76d8\u7ba1\u5206\u533a<\/td><\/tr>\n      <tr><td>\u98ce\u8981\u67d4\u548c\u4e0d\u80fd\u51b0\u78b4\u5b50<\/td><td>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u533a\u522b\u4e8e\u6c1f\u673a\u76f4\u5439\u51b7\u98ce<\/td><td>\u6c34\u7cfb\u7edf\u67d4\u98ce\u5bf9\u75c7<\/td><td>\u96f6\u8d8a\u98ce\u76d8 + \u6c34\u7cfb\u7edf\u5929\u7136\u4f18\u52bf<\/td><\/tr>\n      <tr><td>\u5730\u6696\u8981\u7701\u8d39\u7528<\/td><td>\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa<\/td><td>\u521d\u6295\u96c6\u4e2d\u4f46\u957f\u671f\u603b\u8d26\u66f4\u7701<\/td><td>\u6c34\u5885\u9002\u5168\u53d8\u9891 + \u4e00\u6b21\u7cfb\u7edf<\/td><\/tr>\n    <\/tbody><\/table>\n\n    <div class=\"lm-card\">\n      <div class=\"ct\">\ud83c\udfaf \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/div>\n      <ol class=\"lm-goals\">\n        <li><b>\u544a\u522b\u6c1f\u673a\u51b0\u98ce\u523a\u9aa8\uff1a<\/b>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u63a5\u8fd1\u81ea\u7136\u98ce\uff0c\u4e0d\u50cf\u6c1f\u673a\"\u51b0\u78b4\u5b50\u98ce\"\u76f4\u5439\uff0c\u8001\u4eba\u5c0f\u5b69\u4e45\u5f85\u66f4\u8212\u9002\u3002<\/li>\n        <li><b>\u51fa\u98ce\u67d4\u548c\u4e0d\u5e72\u71e5\uff1a<\/b>\u98ce\u673a\u76d8\u7ba1\u51fa\u98ce15-20\u2103\uff0c\u4e0d\u76f4\u5439\u51b0\u624b\u3001\u5439\u4e45\u4e0d\u5934\u75bc\u3002<\/li>\n        <li><b>\u5730\u6696\u7701\u8d39\uff1a<\/b>\u4e00\u5957\u4e3b\u673a\u51ac\u5b63\u4ea735-45\u2103\u6e29\u6c34\u76f4\u4f9b\u5730\u6696\uff0c\u5168\u53d8\u9891\u6309\u9700\uff0c\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa<\/li>\n        <li><b>\u7701\u5fc3\u8010\u7528\uff1a<\/b>\u4e09\u65b9\u8054\u4fdd + \u76d1\u7406 + \u4e91\u7aef\u8bb0\u5f55 + \u4f1a\u5458\u5ef6\u4fdd\uff0c\u89e3\u51b3\"\u6015\u7ef4\u4fee\u9ebb\u70e6\u3001\u6015\u552e\u540e\u627e\u4e0d\u5230\u4eba\"\u3002<\/li>\n      <\/ol>\n    <\/div>\n  <\/div>\n<\/details>\n\n<!-- \u2550\u2550 S2 \u00b7 \u6237\u578b\u70ed\u8d1f\u8377\u8bca\u65ad\u4e0e\u65b9\u6848\u8bbe\u8ba1\u4f9d\u636e \u2550\u2550 -->\n<details class=\"lm-fold\" id=\"s2\" open=\"\">\n  <summary><h2>S2 \u6237\u578b\u70ed\u8d1f\u8377\u8bca\u65ad\u4e0e\u65b9\u6848\u8bbe\u8ba1\u4f9d\u636e<\/h2><span class=\"fold-ico\">\u25be<\/span><\/summary>\n  <div class=\"lm-fold-body\">\n    <p style=\"margin:0 0 14px;padding:10px 14px;background:var(--lm-warm-bg);border-left:3px solid var(--lm-accent);border-radius:6px;font-size:.9rem;line-height:1.8;color:var(--lm-txt)\">\u91d1\u725b\u533a\u9ad8\u5c42\u4f4f\u5b85\u666e\u904d\u5b58\u5728\u590f\u5b63\u897f\u6652\u3001\u51ac\u5b63\u6e7f\u51b7\uff0c\u672c\u5957\u65b9\u6848\u8d1f\u8377\u53d6\u503c\u5145\u5206\u8003\u8651\u9ad8\u5c42\u56f4\u62a4\u7ed3\u6784\u7279\u70b9\u3002<\/p>\n    <h3>\u5404\u533a\u57df\u7a7a\u8c03\u9762\u79ef\u4e0e\u98ce\u673a\u76d8\u7ba1\u914d\u7f6e<\/h3>\n    <table>\n      <tbody><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u96f6\u8d8a\u98ce\u76d8\u578b\u53f7<\/th><th>\u5236\u51b7\u91cf(kW)<\/th><th>\u6570\u91cf<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385+\u9633\u53f0<\/td><td>39<\/td><td>RFP-119WAR\/DBT\/P + RFP-34WAR\/DBT\/P<\/td><td>6.81+2.5<\/td><td>2\uff08\u53cc\u98ce\u673a\u76d8\u7ba1\u5206\u533a\uff09<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>19<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>4.3<\/td><td>1<\/td><\/tr>\n      <tr><td>\u6b21\u53671<\/td><td>11.5<\/td><td>RFP-34WAR\/DBT\/P<\/td><td>2.5<\/td><td>1<\/td><\/tr>\n      <tr><td>\u6b21\u53672<\/td><td>10.7<\/td><td>RFP-34WAR\/DBT\/P<\/td><td>2.5<\/td><td>1<\/td><\/tr>\n      <tr><td style=\"font-weight:700\">\u5408\u8ba1<\/td><td style=\"font-weight:700\">80.2<\/td><td>5\u53f0\u96f6\u8d8a\u98ce\u76d8<\/td><td style=\"font-weight:700\">18.61<\/td><td style=\"font-weight:700\">5<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"lm-ok\">\u2713 \u8d85\u914d\u7387\u6838\u7b97\uff1a\u5185\u673a\u603b\u51b7\u91cf 18.61kW \u00f7 \u4e3b\u673a\u989d\u5b9a\u5236\u51b7 16kW \u2248 <b>116%<\/b>\uff0c\u5904\u4e8e\u65e5\u7acb\u5382\u5bb6\u5141\u8bb8\u533a\u95f4 50%\u2013130%\uff0c\u517c\u987e\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u4e0e\u9ad8\u5cf0\u4fdd\u969c\u3002<\/div>\n\n    <h3>\u8bbe\u8ba1\u4f9d\u636e \u00b7 \u56fd\u5bb6\u89c4\u8303\u5f15\u7528\uff08\u53cc\u56fd\u6807\uff09<\/h3>\n    <div class=\"lm-card blue\">\n      <div class=\"ct\">\ud83d\udcd0 \u8bbe\u8ba1\u4f9d\u636e \u00b7 \u56fd\u5bb6\u89c4\u8303<\/div>\n      <div style=\"font-size:.9rem;color:var(--lm-txt);line-height:1.95;background:#fff;border:1px solid var(--lm-bd);border-radius:8px;padding:14px 18px;margin-bottom:12px\">\n        \ud83d\udcd0 <b style=\"color:var(--lm-brand)\">GB 50736-2012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/b>\u2014\u2014\u4f4f\u5b85\u7a7a\u8c03\u623f\u95f4\u5ba4\u5185\u8bbe\u8ba1\u53c2\u6570\u3001\u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97\u3001\u8bbe\u5907\u9009\u578b\u4e0e\u6c14\u6d41\u7ec4\u7ec7\u7684\u57fa\u672c\u4f9d\u636e\uff1b<br>\n        \ud83d\udcd0 <b style=\"color:var(--lm-brand)\">JGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/b>\u2014\u2014\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u3001\u6c34\u6e29\u4e0e\u5206\u5ba4\u63a7\u6e29\u7684\u6280\u672f\u4f9d\u636e\u3002\u672c\u6848\u8d1f\u8377\u6821\u6838\u4e0e\u5206\u533a\u914d\u7f6e\u5747\u4ee5\u5176\u4e3a\u7eb2\u3002\n      <\/div>\n      <div style=\"font-size:.86rem;color:var(--lm-txt-lt);line-height:1.9\">\n        \u00b7 \u7ed3\u5408\u6210\u90fd\"\u590f\u70ed\u51ac\u51b7\u3001\u51ac\u5b63\u6e7f\u51b7\"\u6c14\u5019\u7279\u5f81\uff0c\u7a7a\u8c03\u6309 <b style=\"color:var(--lm-brand)\">\u5236\u51b7 160W\/\u33a1\u3001\u5730\u6696 200W\/\u33a1<\/b> \u8d1f\u8377\u6807\u51c6\u6821\u6838\uff1b<br>\n        \u00b7 \u4e3b\u673a\u8fde\u63a5\u7387\u63a7\u5236\u5728\u5382\u5bb6\u5141\u8bb8\u533a\u95f4 <b style=\"color:var(--lm-brand)\">50%\u2013130%<\/b>\uff0c\u672c\u6848\u7ea6 <strong style=\"color:var(--lm-accent-d)\">116%<\/strong>\uff0c\u517c\u987e\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u4e0e\u9ad8\u5cf0\u4fdd\u969c\uff1b<br>\n        \u00b7 \u6c34\u5730\u6696\u5171\u7528\u4e3b\u673a\uff0c\u51ac\u5b6335-45\u2103\u4f4e\u6e29\u6e29\u6c34\u76f4\u4f9b\uff0c\u7b26\u5408 JGJ 142 \u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u8981\u6c42\u3002\n      <\/div>\n    <\/div>\n\n    <h3>\u4e3a\u4ec0\u4e48\u9009\u6c34\u5885\u9002 + \u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf<\/h3>\n    <div class=\"lm-card\">\n      <p style=\"margin:0 0 8px\"><b>\u5bf9\u75c7\u6c1f\u673a\u75db\u70b9\uff1a<\/b>\u6c34\u7cfb\u7edf\u7531\u4e3b\u673a\u5148\u628a\u6c34\u964d\u6e29\/\u5347\u6e29\uff0c\u518d\u7531\u6c34\u53bb\u623f\u95f4\u6362\u70ed\uff0c\u51fa\u98ce15-20\u2103\u63a5\u8fd1\u81ea\u7136\u98ce\uff0c\u67d4\u548c\u3001\u4e0d\u5e72\u71e5\u3001\u4e0d\u523a\u9aa8\uff0c\u5b8c\u7f8e\u89e3\u51b3\u6c64\u5148\u751f\"\u5439\u5b8c\u6c1f\u673a\u4e0d\u8212\u670d\"\u3002<\/p>\n      <p style=\"margin:0\"><b>\u514d\u7f13\u51b2\u6c34\u7bb1\u7684\u79d1\u5b66\u6027\uff1a<\/b>\u65e5\u7acb\u6c34\u5885\u9002\u5b98\u65b9\u6807\u51c6\u2014\u2014\u6700\u5c0f\u6c34\u5bb9\u91cf=\u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf(kW)\u00d72\u3002\u672c\u6848 RAS-160\uff0816kW\uff09\u7cfb\u7edf\u603b\u6c34\u91cf\u7ea676L\uff0c\u8fdc\u8d85\u6807\u51c6\u503c32L\uff08\u8d85\u68072.4\u500d\uff09\uff0c<b>\u5b8c\u5168\u65e0\u9700\u7f13\u51b2\u6c34\u7bb1<\/b>\u3002\u514d\u6c34\u7bb1\u8ba9\u7cfb\u7edf\u7ed3\u6784\u66f4\u7b80\u6d01\u3001\u6545\u969c\u70b9\u66f4\u5c11\u3001\u5f00\u673a\u54cd\u5e94\u66f4\u5feb\u3001\u7701\u53bb\u6c34\u7bb1\u5360\u5730\u4e0e\u8d39\u7528\uff0c\u662f\u5168\u53d8\u9891\u4e3b\u673a\u7684\u539f\u751f\u6700\u4f18\u89e3\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/details>\n\n<!-- \u2550\u2550 S3 \u00b7 \u5b8c\u6574\u8bbe\u5907\u914d\u7f6e\u6e05\u5355 & \u7cfb\u7edf\u539f\u7406 \u2550\u2550 -->\n<details class=\"lm-fold\" id=\"s3\" open=\"\">\n  <summary><h2>S3 \u5b8c\u6574\u8bbe\u5907\u914d\u7f6e\u6e05\u5355 &amp; \u7cfb\u7edf\u539f\u7406<\/h2><span class=\"fold-ico\">\u25be<\/span><\/summary>\n  <div class=\"lm-fold-body\">\n    <h3>\u4e3b\u673a\u4e0e\u7cfb\u7edf\u5f62\u5f0f<\/h3>\n    <div class=\"lm-card\">\n      <table>\n        <tbody><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><\/tr>\n        <tr><td>\u4e3b\u673a<\/td><td>\u65e5\u7acb \u6c34\u5885\u9002 <b>RAS-160FPUEN2Q\/M<\/b>\uff08\u5168\u53d8\u9891\uff0c7\u5339 \/ \u5236\u51b7\u91cf\u7ea616kW\uff09<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u5f62\u5f0f<\/td><td><b>\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf<\/b>\u2014\u2014\u5168\u53d8\u9891\u4e3b\u673a\u76f4\u8fde\u672b\u7aef\uff0c\u7cfb\u7edf\u603b\u6c34\u91cf\u7ea676L\uff0c\u8fdc\u8d85\u65e5\u7acb\u6807\u51c6\uff0832L\uff09\uff0c\u5b8c\u5168\u65e0\u9700\u6c34\u7bb1<\/td><\/tr>\n        <tr><td>\u9002\u7528\u9762\u79ef<\/td><td>\u5957\u5185\u7ea680\u33a1\uff0c\u51b7\u6696\u4e00\u4f53\uff1b\u5168\u53d8\u9891\u6309\u9700\u8f93\u51fa\uff0c\u90e8\u5206\u8d1f\u8377\u66f4\u7701<\/td><\/tr>\n        <tr><td>\u51fa\u98ce\u6e29\u5ea6<\/td><td>\u98ce\u96e8\u76d8\u7ba1\u51fa\u98ce 15-20\u2103\uff0c\u63a5\u8fd1\u81ea\u7136\u98ce\uff0c\u4e0d\u5e72\u71e5\u4e0d\u523a\u9aa8<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <h3>5 \u53f0\u96f6\u8d8a\u98ce\u76d8\u914d\u7f6e\u6e05\u5355<\/h3>\n    <table>\n      <tbody><tr><th>\u623f\u95f4<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u96f6\u8d8a\u98ce\u76d8\u578b\u53f7<\/th><th>\u5236\u51b7\u91cf(kW)<\/th><th>\u6570\u91cf<\/th><th>\u914d\u7f6e\u8bf4\u660e<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385+\u9633\u53f0<\/td><td>39<\/td><td>RFP-119WAR\/DBT\/P + RFP-34WAR\/DBT\/P<\/td><td>6.81+2.5<\/td><td>2<\/td><td>\u53cc\u98ce\u673a\u76d8\u7ba1\u5206\u533a\u72ec\u7acb\u63a7\u6e29\uff0c\u5de6\u5385\u53f3\u9910\u5385\u5404\u53f8\u5176\u804c<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>19<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>4.3<\/td><td>1<\/td><td>\u4f4e\u566a\u9759\u97f3\uff0c\u7761\u7720\u7ea7\u8fd0\u884c<\/td><\/tr>\n      <tr><td>\u6b21\u53671<\/td><td>11.5<\/td><td>RFP-34WAR\/DBT\/P<\/td><td>2.5<\/td><td>1<\/td><td>\u6697\u85cf\u5b89\u88c5\uff0c\u7075\u6d3b\u9002\u914d\u5c0f\u623f\u95f4<\/td><\/tr>\n      <tr><td>\u6b21\u53672<\/td><td>10.7<\/td><td>RFP-34WAR\/DBT\/P<\/td><td>2.5<\/td><td>1<\/td><td>\u6697\u85cf\u5b89\u88c5\uff0c\u8282\u7701\u540a\u9876\u7a7a\u95f4<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"lm-ok\">\u2713 \u9009\u578b\u6838\u5339\u914d\uff1a\u5ba2\u9910\u5385\u53cc\u98ce\u673a\u76d8\u7ba1119+34\u5b9e\u73b0\u5206\u533a\u72ec\u7acb\u63a7\u6e29\uff0c\u4e3b\u536768\u3001\u4e24\u6b21\u5367\u540434\uff0c5\u53f0\u96f6\u8d8a\u98ce\u76d8\u51b7\u91cf\u4f59\u91cf\u5145\u8db3\uff0c\u517c\u987e\u8212\u9002\u4e0e\u8282\u80fd\u3002<\/div>\n\n    <h3>\u6c34\u5730\u6696\u7cfb\u7edf\uff08\u5171\u7528\u4e3b\u673a\uff09<\/h3>\n    <div class=\"lm-card blue\">\n      <p style=\"margin:0 0 8px\">\u5730\u6696\u4e0e\u5236\u51b7\u5171\u7528\u540c\u4e00\u53f0\u6c34\u5885\u9002\u4e3b\u673a\uff0c\u51ac\u5b63\u4e3b\u673a\u4ea7\u51fa <b>35-45\u2103 \u4f4e\u6e29\u6e29\u6c34\u76f4\u63a5\u9001\u5165\u5730\u6696\u76d8\u7ba1<\/b>\uff0c\u65e0\u4e8c\u6b21\u6362\u70ed\u3001\u65e0\u71c3\u6c14\u6d88\u8017\uff0c\u8fd0\u884c\u8d39\u8f83\u71c3\u6c14\u58c1\u6302\u7089\u6709\u671b\u66f4\u4f4e\uff08\u5b9e\u9645\u4ee5\u6237\u7528\u5b9e\u6d4b\u4e3a\u51c6\uff09\u3002<\/p>\n      <table>\n        <tbody><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u5355\u4ef7<\/th><th>\u91c7\u6696\u9762\u79ef<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n        <tr><td>\u5730\u6696\u8f85\u6750 \u00b7 \u8282\u80fd\u5957\u9910<\/td><td>\u52a0\u5bc6\u94fa\u7ba1+\u52a0\u539a\u4fdd\u6e29\uff0c\u70ed\u635f\u66f4\u4f4e<\/td><td>\u00a5169\/\u33a1<\/td><td>\u7ea677\u33a1<\/td><td>\u00a513,013<\/td><\/tr>\n      <\/tbody><\/table>\n      <p style=\"font-size:.82rem;color:var(--lm-txt-lt);margin:8px 0 0\">\u6ce8\uff1a\u6848\u4f8b\u5206\u4eab\u4e0d\u5c55\u793a\u4e1a\u4e3b\u5177\u4f53\u652f\u4ed8\u91d1\u989d\uff0c\u6b64\u5904\u4ec5\u5217\u7cfb\u7edf\u914d\u7f6e\u4e0e\u6750\u6599\u5355\u4ef7\uff0c\u4f9b\u540c\u6237\u578b\u53c2\u8003\uff1b\u5730\u6696\u56de\u586b\u3001\u627e\u5e73\u5c5e\u571f\u5efa\u5de5\u5e8f\uff0c\u4e0d\u5728\u672c\u914d\u7f6e\u5185\u3002<\/p>\n    <\/div>\n\n    <h3>\u7cfb\u7edf\u539f\u7406 \u00b7 \u4e00\u5957\u4e3b\u673a\u5168\u5c4b\u51b7\u6696<\/h3>\n    <div class=\"lm-card\">\n      <p style=\"margin:0\">\u590f\u5b63\uff1a\u4e3b\u673a\u5236\u53d6\u51b7\u6c34 \u2192 \u98ce\u673a\u76d8\u7ba1\u5236\u51b7\uff08\u51fa\u98ce15-20\u2103\u67d4\u98ce\uff09\uff1b\u51ac\u5b63\uff1a\u540c\u4e00\u4e3b\u673a\u5236\u53d635-45\u2103\u6e29\u6c34 \u2192 \u76f4\u4f9b\u6c34\u5730\u6696\u76d8\u7ba1\u8f90\u5c04\u4f9b\u6696\u3002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\uff0c\u4e00\u5957\u7cfb\u7edf\u8986\u76d6\u5168\u5c4b\u51b7\u6696\uff0c\u5168\u53d8\u9891\u6309\u9700\u8f93\u51fa\uff0c\u90e8\u5206\u8d1f\u8377\u66f4\u7701\u66f4\u9759\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/details>\n\n<!-- \u2550\u2550 S4 \u00b7 \u6807\u51c6\u5316\u65bd\u5de5\u8fc7\u7a0b & \u9690\u853d\u9a8c\u6536\u5b9e\u62cd \u2550\u2550 -->\n<details class=\"lm-fold\" id=\"s4\" open=\"\">\n  <summary><h2>S4 \u6807\u51c6\u5316\u65bd\u5de5\u8fc7\u7a0b &amp; \u9690\u853d\u9a8c\u6536\u5b9e\u62cd<\/h2><span class=\"fold-ico\">\u25be<\/span><\/summary>\n  <div class=\"lm-fold-body\">\n    <h3>\u7cbe\u5de5\u65bd\u5de5\u516b\u5927\u9636\u6bb5<\/h3>\n    <table>\n      <tbody><tr><th>\u9636\u6bb5<\/th><th>\u5de5\u5e8f<\/th><th>\u63a7\u5236\u8981\u70b9<\/th><\/tr>\n      <tr><td>\u2460 \u73b0\u573a\u52d8\u6d4b<\/td><td>\u590d\u6d4b\u9762\u79ef\u3001\u673a\u4f4d\u3001\u6881\u4f4d\u3001\u6c34\u538b<\/td><td>\u786e\u8ba4\u65bd\u5de5\u6761\u4ef6\u4e0e\u8d1f\u8377\u57fa\u6570<\/td><\/tr>\n      <tr><td>\u2461 \u65b9\u6848\u8bbe\u8ba1<\/td><td>\u51fa\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u89c4\u5212<\/td><td>DE40\u4e3b\u5e72+DE32+DE25\u652f\u7ba1\u5e03\u5c40<\/td><\/tr>\n      <tr><td>\u2462 \u8f85\u6750\u8fdb\u573a<\/td><td>\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u6838\u9a8c<\/td><td>\u539f\u5382\u5408\u683c\u8bc1\u3001\u58c1\u539a\u6838\u9a8c<\/td><\/tr>\n      <tr><td>\u2463 \u8bbe\u5907\u5b89\u88c5<\/td><td>\u4e3b\u673a\u51cf\u632f\u3001\u98ce\u673a\u76d8\u7ba1\u6697\u85cf\u3001\u7ebf\u63a7\u5668<\/td><td>\u53cc\u87ba\u6bcd\u51cf\u9707\u3001\u5b9a\u4f4d\u7cbe\u51c6<\/td><\/tr>\n      <tr><td>\u2464 \u7ba1\u8def\u710a\u63a5<\/td><td>\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5<\/td><td>\u5145\u6c2e\u710a\u63a5\u9632\u6c27\u5316\u3001\u5185\u58c1\u6d01\u51c0<\/td><\/tr>\n      <tr><td>\u2465 \u5730\u6696\u94fa\u8bbe<\/td><td>\u76d8\u7ba1\u52a0\u5bc6\u94fa\u8bbe+\u4fdd\u6e29<\/td><td>\u95f4\u8ddd\u5747\u5300\u3001\u6253\u538b\u8bd5\u9a8c<\/td><\/tr>\n      <tr><td>\u2466 \u4fdd\u538b\u8c03\u8bd5<\/td><td>\u62bd\u771f\u7a7a\u3001\u6c2e\u6c14\u4fdd\u538b<\/td><td>0.6MPa\u4fdd\u538b24h\u538b\u964d\u22640.05MPa<\/td><\/tr>\n      <tr><td>\u2467 \u8c03\u8bd5\u9a8c\u6536<\/td><td>\u5236\u51b7\/\u5730\u6696\u53cc\u6a21\u5f0f\u8c03\u8bd5<\/td><td>\u5206\u5ba4\u6e29\u63a7\u6821\u51c6\u3001\u4ea4\u4ed8\u8d28\u4fdd\u5361<\/td><\/tr>\n    <\/tbody><\/table>\n\n    <h3>\u56db\u9879\u9690\u853d\u9a8c\u6536\u7ec6\u8282\uff08\u91cf\u5316\uff09<\/h3>\n    <div class=\"lm-card blue\">\n      <ol class=\"lm-goals\">\n        <li><b>\u2460 \u6750\u6599\u9a8c\u6536\uff1a<\/b>\u65e5\u7acb\u539f\u5382\u96f6\u8d8a\u98ce\u76d8 + \u7d2b\u94dc\u7ba1\uff08\u58c1\u539a\u22650.8mm\uff09\u8fdb\u573a\u6838\u9a8c\uff0c\u67e5\u5408\u683c\u8bc1\u4e0e\u5e8f\u5217\u53f7\uff0c\u675c\u7edd\u4e32\u8d27\u3002<\/li>\n        <li><b>\u2461 \u6c34\u538b\u6253\u538b\uff1a<\/b>\u7a7a\u8c03\u6c34\u8def <b>0.6MPa \u4fdd\u538b 24h<\/b>\uff0c\u538b\u964d \u22640.05MPa \u4e3a\u5408\u683c\uff08\u6c2e\u6c14\u4fdd\u538b\u8868\u8bfb\u6570\u590d\u6838\uff09\uff0c\u786e\u4fdd\u65e0\u6e17\u6f0f\u3002<\/li>\n        <li><b>\u2462 \u7ba1\u8def\u8d70\u5411\uff1a<\/b>DE40 \u4e3b\u5e72 + DE32 + DE25 \u652f\u7ba1\uff0c\u6a2a\u5e73\u7ad6\u76f4\u3001\u5761\u5ea6\u5408\u89c4\uff0c\u51b7\u51dd\u6c34\u7ba1\u8bbe\u6392\u6c14\u5b54\u9632\u6c14\u5835\u3002<\/li>\n        <li><b>\u2463 \u5206\u5ba4\u8c03\u8bd5\uff1a<\/b>5 \u53f0\u98ce\u673a\u76d8\u7ba1\u72ec\u7acb\u6e29\u63a7\u6821\u51c6\uff0c\u5236\u51b7\/\u5730\u6696\u53cc\u6a21\u5f0f\u5207\u6362\u6d4b\u8bd5\uff0c\u5404\u623f\u95f4\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6\u65e0\u5f02\u5e38\u3002<\/li>\n      <\/ol>\n    <\/div>\n\n    <h3>\u65bd\u5de5\u5b9e\u666f\u9a8c\u6536\u56fe\u96c6\uff08\u9f99\u8109\u7cbe\u5de5\u540c\u6807\u51c6\u5de5\u827a\uff09<\/h3>\n    <p style=\"font-size:.82rem;color:var(--lm-txt-lt);margin:6px 0 10px\">\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff0c\u5bf9\u5e94\u516b\u5927\u9636\u6bb5\u63a7\u5236\u70b9\uff1b\u672c\u6848\u6c64\u5148\u751f\u5bb6\u65bd\u5de5\u6309\u540c\u7b49\u5de5\u827a\u6267\u884c\u3002<\/p>\n    <div class=\"lm-gallery\">\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536\u5b9e\u62cd\"><figcaption>\u2460 \u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u94dc\u7ba1\u58c1\u539a\u6838\u9a8c\u5b9e\u62cd\"><figcaption>\u2461 \u94dc\u7ba1\u58c1\u539a\u6838\u9a8c<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-frdl.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u5b9e\u62cd\"><figcaption>\u2462 \u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\u5b9e\u62cd\"><figcaption>\u2463 \u5185\u673a\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xhmpqk.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u51b7\u51dd\u6c34\u7ba1\u6392\u6c14\u5b54\u5b9e\u62cd\"><figcaption>\u2464 \u51b7\u51dd\u6c34\u7ba1\u6392\u6c14\u5b54<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b\u5b9e\u62cd\"><figcaption>\u2465 \u5916\u673a\u62bd\u771f\u7a7a\u4fdd\u538b<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u6c2e\u6c14\u4fdd\u538b\u8868\u8bfb\u6570\u5b9e\u62cd\"><figcaption>\u2466 \u6c2e\u6c14\u4fdd\u538b\u8868\u8bfb\u6570<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\u5b9e\u62cd\"><figcaption>\u2467 \u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-czkby.jpg\" alt=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u7cfb\u7edf\u8c03\u8bd5\u9a8c\u6536\u5b9e\u62cd\"><figcaption>\u2468 \u7cfb\u7edf\u8c03\u8bd5\u9a8c\u6536<\/figcaption><\/figure>\n    <\/div>\n\n    <h3>\u54c1\u724c\u6388\u6743\u8d44\u8d28\uff08E-E-A-T \u4fe1\u4efb\u80cc\u4e66\uff09<\/h3>\n    <div class=\"lm-cert-grid\">\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u7cfb\u7edf\uff08\u6c34\u5885\u9002\uff09\u7279\u7ea6\u7ecf\u9500\u6388\u6743\"><figcaption>\u65e5\u7acb\u6c34\u7cfb\u7edf\u7279\u7ea6\u7ecf\u9500\u6388\u6743<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743\"><figcaption>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743<\/figcaption><\/figure>\n      <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743\"><figcaption>\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u8ba4\u8bc1\u6388\u6743<\/figcaption><\/figure>\n    <\/div>\n  <\/div>\n<\/details>\n\n<!-- \u2550\u2550 S5 \u00b7 \u843d\u5730\u6548\u679c\u590d\u76d8 + \u4e1a\u4e3b\u8bc4\u4ef7 \u2550\u2550 -->\n<details class=\"lm-fold\" id=\"s5\" open=\"\">\n  <summary><h2>S5 \u843d\u5730\u6548\u679c\u590d\u76d8 + \u4e1a\u4e3b\u8bc4\u4ef7<\/h2><span class=\"fold-ico\">\u25be<\/span><\/summary>\n  <div class=\"lm-fold-body\">\n    <h3>\u6548\u679c\u590d\u76d8<\/h3>\n    <div class=\"lm-card\">\n      <table>\n        <tbody><tr><th>\u9a8c\u8bc1\u7ef4\u5ea6<\/th><th>\u843d\u5730\u7ed3\u8bba<\/th><\/tr>\n        <tr><td>\u544a\u522b\u6c1f\u673a\u51b0\u98ce<\/td><td>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\u67d4\u98ce\uff0c\u6c1f\u673a7-12\u2103\u51b0\u98ce\u2014\u2014\u4f53\u611f\u5929\u58e4\u4e4b\u522b<\/td><\/tr>\n        <tr><td>\u51fa\u98ce\u67d4\u548c\u4e0d\u5e72\u71e5<\/td><td>\u6c34\u7cfb\u7edf15-20\u2103\u67d4\u98ce\uff0c\u544a\u522b\"\u51b0\u78b4\u5b50\u98ce\"\uff0c\u8001\u4eba\u5c0f\u5b69\u4e45\u5f85\u8212\u9002<\/td><\/tr>\n        <tr><td>\u5730\u6696\u7701\u8d39<\/td><td>\u5171\u7528\u4e3b\u673a\u4ea7\u4f4e\u6e29\u6e29\u6c34\uff0c\u5168\u53d8\u9891\u6309\u9700\uff0c\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa<\/td><\/tr>\n        <tr><td>\u514d\u6c34\u7bb1\u4f18\u52bf<\/td><td>\u7cfb\u7edf\u6c34\u91cf76L\u8d85\u65e5\u7acb\u6807\u51c62.4\u500d\uff0c\u7ed3\u6784\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11\u3001\u54cd\u5e94\u5feb<\/td><\/tr>\n        <tr><td>\u8d85\u914d\u7387<\/td><td>\u5185\u673a18.61kW\u00f7\u4e3b\u673a16kW\u2248116%\uff0c\u5408\u89c450-130%<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n\n    <h3>\u4e1a\u4e3b\u771f\u5b9e\u4f53\u611f\uff08\u53c2\u8003\u540c\u8def\u7ebf\u4e24\u8054\u4f9b\u5b9e\u6d4b\u5bf9\u6807\uff09<\/h3>\n    <div class=\"lm-note\">\n      \ud83d\udcdd \u8bf4\u660e\uff1a\u4ee5\u4e0b\u4f53\u611f\u6570\u636e\u6765\u81ea\u9f99\u8109\u6696\u901a\u540c\u8def\u7ebf\uff08\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\uff09\u5df2\u5b8c\u5de5\u6848\u4f8b\u5b9e\u6d4b\u5bf9\u6807\uff0c\u4f9b\u4e1a\u4e3b\u53c2\u8003\uff1b\u6c64\u5148\u751f\u5bb6\u771f\u5b9e\u4f53\u611f\u8bc4\u4ef7\u968f\u5b8c\u5de5\u56de\u8bbf\u66f4\u65b0\u8865\u5145\u3002\n      <p style=\"margin:8px 0 0;font-size:.84rem;color:var(--lm-txt-lt);line-height:1.8\">\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6237\u578b\u5b8c\u5de5\u6848\u4f8b\u5bf9\u6807\u4f53\u611f\uff0c\u672c\u6237\u5b9e\u9645\u6548\u679c\u4ee5\u5b8c\u5de5\u8c03\u8bd5\u540e\u7684\u73b0\u573a\u5b9e\u6d4b\u4e3a\u51c6\u3002<\/p>\n      <ul style=\"margin:8px 0 0;padding-left:20px;line-height:1.8\">\n        <li>\u5236\u51b7\uff1a\u5f00\u673a\u7ea615-20\u5206\u949f\u5ba4\u6e29\u964d\u81f3\u8bbe\u5b9a\u503c\uff0c\u51fa\u98ce\u67d4\u548c\u65e0\u51b0\u611f\uff0c\u591c\u95f4\u5367\u5ba4\u7ea626\u2103\u4f53\u611f\u8212\u9002\uff1b<\/li>\n        <li>\u5730\u6696\uff1a\u51ac\u5b63\u4f9b\u6c3435-45\u2103\uff0c\u5ba4\u5185\u5730\u9762\u8f90\u5c04\u5347\u6e29\uff0c\u5ba4\u6e29\u7a33\u5b9a18-22\u2103\uff0c\u65e0\u7a7a\u8c03\u76f4\u5439\u5e72\u71e5\u611f\uff1b<\/li>\n        <li>\u8fd0\u884c\u8d39\uff1a\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002<\/li>\n      <\/ul>\n    <\/div>\n\n    <h3>\u4e1a\u4e3b\u8bc4\u4ef7\uff08\u5b8c\u5de5\u56de\u8bbf\u5f52\u6863\uff09<\/h3>\n    <div class=\"lm-card blue\">\n      <p style=\"margin:0;font-style:italic;color:var(--lm-txt-lt)\">\"\u6c64\u5148\u751f\u5bb6\u771f\u5b9e\u56de\u8bbf\u8bc4\u4ef7\u7531\u987e\u95ee\u5f90\u65b0\u5e73\u5728\u65bd\u5de5\u5b8c\u5de5\u540e\u8865\u5145\u5f52\u6863\u3002\"\uff08\u672c\u6848\u4f8b\u7531\u65b9\u6848\u4ea4\u4ed8\u8f6c\u5316\uff0c\u4e1a\u4e3b\u771f\u5b9e\u4f53\u611f\u8bc4\u4ef7\u968f\u5b8c\u5de5\u56de\u8bbf\u66f4\u65b0\u3002\uff09<\/p>\n    <\/div>\n\n    <h3>\u552e\u540e\u627f\u8bfa\uff08E-E-A-T\uff09<\/h3>\n    <div class=\"lm-card\">\n      <p style=\"margin:0\">\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a\u539f\u5382\u8d28\u4fdd + \u9f99\u8109\u5b89\u88c5\u8d28\u4fdd + \u4f1a\u5458\u5ef6\u4fdd\u4e09\u5c42\u4fdd\u969c\uff1b<b>24\u5c0f\u65f6\u5e94\u6025\u4e0a\u95e8<\/b>\uff0c\u7ef4\u4fdd\u8303\u56f4\u4e0e\u914d\u4ef6\u4fdd\u4fee\u65f6\u957f\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd22\u5e74\u672c\u5730\u670d\u52a1\u5546\uff0c\u81ea\u6709\u65bd\u5de5\u4e0e\u552e\u540e\u56e2\u961f\uff0c\u54cd\u5e94\u53ca\u65f6\u3002<\/p>\n    <\/div>\n  <\/div>\n<\/details>\n\n<!-- \u2550\u2550 \u6a21\u5757\u4e94 \u533a\u57571\uff1aFAQ \u2550\u2550 -->\n<div class=\"lm-section-h2\" id=\"faq\"><h2>\u9ad8\u9891\u95ee\u7b54 \u00b7 \u4e1a\u4e3b\u5e38\u95ee<\/h2><\/div>\n<div class=\"lm-wrap\">\n  <div class=\"lm-faq\">\n    <details><summary>\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u8fd9\u79cd\u5957\u4e09\uff0c\u80fd\u505a\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5417\uff1f<\/summary><div class=\"faq-a\">\u5b8c\u5168\u53ef\u4ee5\u3002\u672c\u6848\u6c64\u5148\u751f\u5bb6\u5c31\u662f\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u7ea690\u33a1\u5957\u4e09\uff0c\u7a7a\u8c03\u9762\u79ef\u7ea680\u33a1\uff0c\u91c7\u7528 RAS-160 \u5168\u53d8\u9891\u4e3b\u673a + 5\u53f0\u96f6\u8d8a\u98ce\u76d8\uff08\u5ba2\u9910\u5385\u53cc\u98ce\u673a\u76d8\u7ba1\u5206\u533a\u3001\u4e3b\u5367\u4e0e\u4e24\u6b21\u5367\u72ec\u7acb\u6e29\u63a7\uff09+ \u6c34\u5730\u6696\u5171\u7528\u4e3b\u673a\uff0c\u4e00\u5957\u7cfb\u7edf\u8986\u76d6\u5168\u5c4b\u51b7\u6696\u3002\u5957\u4e09\u3001\u5957\u56db\u4e43\u81f3\u5927\u5e73\u5c42\u5747\u53ef\u6309\u9762\u79ef\u4e0e\u5206\u533a\u505a\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b9a\u5236\u3002<\/div><\/details>\n    <details><summary>\u6c34\u7cfb\u7edf\u548c\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u5230\u5e95\u5dee\u5728\u54ea\uff1f\u6c64\u5148\u751f\u4e3a\u4ec0\u4e48\u9009\u6c34\u5885\u9002\uff1f<\/summary><div class=\"faq-a\">\u6838\u5fc3\u5dee\u5728\"\u6362\u70ed\u4ecb\u8d28\"\u3002\u6c1f\u673a\u51b7\u5a92\u76f4\u63a5\u8fdb\u623f\u95f4\uff0c\u51fa\u98ce7-12\u2103\u53c8\u51b7\u53c8\u5e72\uff0c\u5439\u4e45\u5bb9\u6613\u5934\u75bc\u53e3\u5e72\uff1b\u6c34\u673a\u4e3b\u673a\u5148\u628a\u6c34\u964d\u6e29\/\u5347\u6e29\uff0c\u518d\u7531\u6c34\u53bb\u623f\u95f4\u6362\u70ed\uff0c\u51fa\u98ce15-20\u2103\u63a5\u8fd1\u81ea\u7136\u98ce\uff0c<b>\u67d4\u548c\u3001\u4e0d\u5e72\u71e5\u3001\u4e0d\u523a\u9aa8<\/b>\u3002\u6c64\u5148\u751f\u6b64\u524d\u5439\u5b8c\u6c1f\u673a\u5f88\u4e0d\u8212\u670d\uff0c\u6362\u6c34\u7cfb\u7edf\u540e\u4f53\u611f\u6539\u5584\u660e\u663e\uff0c\u8fd9\u662f\u4ed6\u9009\u6c34\u5885\u9002\u7684\u6839\u672c\u539f\u56e0\u3002<\/div><\/details>\n    <details><summary>\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\uff0c\u4f1a\u4e0d\u4f1a\u6c34\u6e29\u4e0d\u7a33\u3001\u4e3b\u673a\u9891\u7e41\u542f\u505c\uff1f<\/summary><div class=\"faq-a\"><b>\u4e0d\u4f1a\u3002<\/b>\u65e5\u7acb\u6c34\u5885\u9002\u5b98\u65b9\u6807\u51c6\uff1a\u6700\u5c0f\u6c34\u5bb9\u91cf=\u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf(kW)\u00d72\u3002\u672c\u6848 RAS-160\uff0816kW\uff09\u7cfb\u7edf\u603b\u6c34\u91cf\u7ea676L\uff0c\u800c\u6807\u51c6\u4ec5\u970032L\u2014\u2014\u8d85\u68072.4\u500d\uff0c\u5b8c\u5168\u4e0d\u9700\u8981\u7f13\u51b2\u6c34\u7bb1\u3002\u514d\u6c34\u7bb1\u8ba9\u7cfb\u7edf\u66f4\u7b80\u6d01\u3001\u6545\u969c\u70b9\u66f4\u5c11\u3001\u5f00\u673a\u54cd\u5e94\u66f4\u5feb\uff0c\u662f\u5168\u53d8\u9891\u4e3b\u673a\u7684\u539f\u751f\u6700\u4f18\u89e3\u3002<\/div><\/details>\n    <details><summary>90\u33a1\u4e24\u8054\u4f9b\u4ece\u52d8\u6d4b\u5230\u5b8c\u5de5\u5927\u6982\u8981\u591a\u4e45\uff1f<\/summary><div class=\"faq-a\">\u6807\u51c6\u5468\u671f\u7ea6 7-12 \u4e2a\u5de5\u4f5c\u65e5\uff08\u89c6\u571f\u5efa\u914d\u5408\uff09\uff1a\u73b0\u573a\u52d8\u6d4b1\u5929 \u2192 \u65b9\u6848\u51fa\u56fe1-2\u5929 \u2192 \u8bbe\u5907\u6750\u6599\u8fdb\u573a\u4e0e\u7ba1\u8def\/\u98ce\u673a\u76d8\u7ba1\u5b89\u88c53-5\u5929 \u2192 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe2-3\u5929 \u2192 \u62bd\u771f\u7a7a\u4fdd\u538b\u4e0e\u53cc\u6a21\u5f0f\u8c03\u8bd51-2\u5929 \u2192 \u9a8c\u6536\u4ea4\u4ed8\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u516b\u5927\u9636\u6bb5\u7ba1\u63a7\uff0c\u9690\u853d\u5de5\u7a0b\u8282\u70b9\u7559\u5b58\u9a8c\u6536\u5355\u3002<\/div><\/details>\n    <details><summary>\u6210\u90fd\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5305\u542b\u54ea\u4e9b\u8d28\u4fdd\uff1f\u514d\u6c34\u7bb1\u540e\u671f\u7ef4\u62a4\u9ebb\u70e6\u5417\uff1f<\/summary><div class=\"faq-a\">\u4e09\u5c42\u4fdd\u969c\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a\u539f\u5382\u8d28\u4fdd + \u9f99\u8109\u5b89\u88c5\u8d28\u4fdd + \u4f1a\u5458\u5ef6\u4fdd\uff1b\u63d0\u4f9b24\u5c0f\u65f6\u5e94\u6025\u4e0a\u95e8\u3002\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\u90e8\u4ef6\u66f4\u5c11\uff0c\u53cd\u800c<b>\u7ef4\u62a4\u66f4\u7b80\u5355<\/b>\u2014\u2014\u6ca1\u6709\u6c34\u7bb1\u8fd9\u4e2a\u989d\u5916\u90e8\u4ef6\uff0c\u6f5c\u5728\u6545\u969c\u70b9\u66f4\u5c11\uff0c\u65e5\u5e38\u4ec5\u9700\u5b9a\u671f\u6e05\u6d17\u98ce\u673a\u76d8\u7ba1\u6ee4\u7f51\u3001\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\u5373\u53ef\u3002<\/div><\/details>\n    <details><summary>\u4e24\u8054\u4f9b\u5730\u6696\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u7701\u591a\u5c11\uff1f<\/summary><div class=\"faq-a\">\u51ac\u5b63\u7528\u4e3b\u673a\u4ea735-45\u2103\u6e29\u6c34\u76f4\u4f9b\u5730\u6696\uff0c\u5168\u53d8\u9891\u6309\u9700\u8f93\u51fa\u3001\u65e0\u71c3\u6c14\u6d88\u8017\uff1b\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002\u4e14\u4e00\u5957\u4e3b\u673a\u517c\u987e\u590f\u5b63\u5236\u51b7\u4e0e\u51ac\u5b63\u5730\u6696\uff0c\u521d\u6295\u96c6\u4e2d\u4f46\u957f\u671f\u603b\u8d26\u66f4\u7701\u3002<\/div><\/details>\n    <details><summary>\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\u548c\u5e26\u7f13\u51b2\u6c34\u7bb1\u65b9\u6848\uff0c\u5206\u522b\u9002\u5408\u4ec0\u4e48\u5bb6\u5ead\uff1f<\/summary><div class=\"faq-a\">\u65e5\u7acb\u6c34\u5885\u9002\u5728\u7cfb\u7edf\u603b\u6c34\u91cf\u6ee1\u8db3\u5b98\u65b9\u6700\u4f4e\u5bb9\u91cf\u8981\u6c42\u65f6\uff0c\u53ef\u91c7\u7528\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\uff0c\u7ed3\u6784\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11\u3001\u5f00\u673a\u54cd\u5e94\u5feb\uff1b\u82e5\u7ba1\u8def\u5f88\u957f\u3001\u672b\u7aef\u6570\u91cf\u6781\u591a\uff0c\u5219\u5efa\u8bae\u914d\u7f6e\u7f13\u51b2\u6c34\u7bb1\uff0c\u4e24\u79cd\u65b9\u6848\u5747\u5408\u89c4\uff0c\u7ed3\u5408\u6237\u578b\u7ba1\u8def\u5b9e\u9645\u60c5\u51b5\u9009\u578b\u3002<\/div><\/details>\n  <\/div>\n<\/div>\n\n<!-- \u2550\u2550 \u6a21\u5757\u4e94 \u533a\u57572\uff1a\u7ad9\u5185\u56de\u6d41\u5185\u94fe \u2550\u2550 -->\n<div class=\"lm-section-h2\" id=\"links\"><h2>\u540c\u7247\u533a\u6848\u4f8b\u4e0e\u65b9\u6848\u5e93 \u00b7 \u5ef6\u4f38\u9605\u8bfb<\/h2><\/div>\n<div class=\"lm-wrap\">\n  <div class=\"lm-links\">\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><b>\u5168\u5c0f\u533a\u5b9e\u666f\u6848\u4f8b\u805a\u5408\u9875<\/b><span class=\"tag\">\u6848\u4f8b\u5e93<\/span>200+\u771f\u5b9e\u5ba2\u6237\u5b8c\u5de5\u5b9e\u666f\uff0c\u540c\u6237\u578b\/\u540c\u7cfb\u7edf\u53c2\u8003<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=5849\" target=\"_blank\"><b>109\u5957\u6237\u578b\u65b9\u6848\u5e93<\/b><span class=\"tag\">\u6237\u578b\u65b9\u6848<\/span>\u6309\u9762\u79ef\/\u6237\u578b\u5339\u914d\u7684\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u914d\u7f6e\u65b9\u6848<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\"><b>\u5730\u6696\u4e13\u9879\u805a\u5408\u9875<\/b><span class=\"tag\">\u5730\u6696<\/span>\u6c34\u5730\u6696\/\u660e\u88c5\u6696\u6c14\u7247\u65bd\u5de5\u5de5\u827a\u4e0e\u7701\u8d39\u5bf9\u6bd4<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=3147\" target=\"_blank\"><b>\u6bcf\u65e5\u65b0\u6848\u4f8b\u65e5\u66f4\u805a\u5408\u9875<\/b><span class=\"tag\">\u65e5\u66f4<\/span>\u9f99\u8109\u6696\u901a\u6700\u65b0\u5b8c\u5de5\u6848\u4f8b\u6301\u7eed\u66f4\u65b0<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\"><b>\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/b><span class=\"tag\">\u7ad9\u70b9\u5730\u56fe<\/span>\u9f99\u8109\u6696\u901a\u5b98\u7f51\u680f\u76ee\u4e0e\u6848\u4f8b\u603b\u7d22\u5f15<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=5809\" target=\"_blank\"><b>\u540c\u8def\u7ebf\u5bf9\u6807 \u00b7 \u9e93\u6e56\u6c84\u5cb8157\u33a1<\/b><span class=\"tag\">\u6c34\u5885\u9002<\/span>\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 \u540c\u5de5\u827a\u5b9e\u666f<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=6029\" target=\"_blank\"><b>\u540c\u8def\u7ebf\u5bf9\u6807 \u00b7 \u9ec4\u9f99\u6eaa\u8c37308\u33a1<\/b><span class=\"tag\">\u53cc\u4e3b\u673a<\/span>\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 \u4e00\u7528\u4e00\u5907<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=8769\" target=\"_blank\"><b>\u65b0\u6d25\u8054\u6392\u522b\u5885\u65e5\u7acb\u6c34\u5885\u9002\u53cc\u673a\u5e76\u673a\u4e24\u8054\u4f9b\u5b8c\u5de5\u6848\u4f8b<\/b><span class=\"tag\">\u540c\u8def\u7ebf\u00b7\u5927\u5b85<\/span>\u53cc\u673a\u4e00\u7528\u4e00\u5907\u5197\u4f59\u914d\u7f6e\u53c2\u8003<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=9918\" target=\"_blank\"><b>\u9526\u6c5f\u533a\u7fe1\u7fe0\u57ce5\u671f\u590d\u5f0f\u8dc3\u5c42\u65e5\u7acb\u6c34\u5885\u9002200\u4e24\u8054\u4f9b\u5b8c\u5de5\u6848\u4f8b<\/b><span class=\"tag\">\u540c\u8def\u7ebf\u00b7\u673a\u957f\u9009\u578b<\/span>\u4e00\u62d6\u4e03 + \u5929\u51c0\u65b0\u98ce + \u96c6\u63a7\u5c4f\u53c2\u8003<\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=14764\" target=\"_blank\"><b>\u6c34\u5885\u9002 FX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97<\/b><span class=\"tag\">\u673a\u578b\u4ef7\u683c<\/span>\u672c\u9875 RAS-160 \u540c\u7cfb\u5217\u673a\u578b\u4ef7\uff1aFX 140\u2013200 \u5171 9 \u6863 + \u6210\u5957\u9884\u7b97<\/a>\n  <\/div>\n<\/div>\n\n<div class=\"lm-section-h2\" id=\"cta\"><h2>\u672c\u5730\u670d\u52a1\u4e0e\u95e8\u5e97 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h2><\/div>\n<div class=\"lm-wrap\">\n  <div class=\"lm-stores\">\n    <div class=\"store\">\n      <div class=\"st-name\">\u5357\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5e97<\/div>\n      \u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<br>\u552e\u540e\u4e13\u7ebf\uff1a028-61649321\n    <\/div>\n    <div class=\"store\">\n      <div class=\"st-name\">\u5317\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5e97<\/div>\n      \u6210\u90fd \u00b7 \u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a\uff08\u5177\u4f53\u533a\u4f4d\u8bf7\u8be2\u95e8\u5e97\uff09<br>\u8be6\u60c5\u81f4\u7535\uff1a028-61649321\n    <\/div>\n  <\/div>\n  <div class=\"lm-cta-box\">\n    <p style=\"margin:0 0 8px\"><b>\u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd22\u5e74\u672c\u5730\u51b7\u6696\u4e00\u4f53\u5316\u96c6\u6210\u670d\u52a1\u5546<\/b>\uff08\u65e5\u7acb\u6c34\u7cfb\u7edf\u7279\u7ea6\u7ecf\u9500\u6388\u6743\uff09<\/p>\n    <p style=\"margin:0 0 8px\"><b>\u670d\u52a1\u8986\u76d6\u533a\u53bf\uff1a<\/b>\u91d1\u725b\u533a\u3001\u6b66\u4faf\u533a\u3001\u53cc\u6d41\u533a\u3001\u9f99\u6cc9\u9a7f\u533a\u3001\u90eb\u90fd\u533a\u3001\u9ad8\u65b0\u533a\u7b49\u6210\u90fd\u5168\u57df\u4e0a\u95e8\u65bd\u5de5\u3002<\/p>\n    <p style=\"margin:0 0 8px\"><b>\u514d\u8d39\u670d\u52a1\uff1a<\/b>\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u51b7\u70ed\u8d1f\u8377\u8ba1\u7b97 \u00b7 \u6237\u578b\u65b9\u6848\u51fa\u5177\u3002<\/p>\n    <p style=\"margin:0\"><b>\u56fa\u5b9a\u54a8\u8be2\u5ea7\u673a\uff1a<\/b>028-61649321 \uff5c \u672c\u6848\u987e\u95ee\u5f90\u65b0\u5e73 \ud83d\udcde 182-2705-5065<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"lm-foot\">\n  <div>\u672c\u6848\u4f8b\u7531 <b>\u9f99\u8109\u6696\u901a<\/b>\uff08\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\uff09\u4ea4\u4ed8 \u00b7 \u6848\u4f8b\u987e\u95ee\uff1a\u5f90\u65b0\u5e73 18227055065<\/div>\n  <div>\u66f4\u65b0\u65e5\u671f\uff1a2026-08 \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\u5168\u53d8\u9891\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u00b7 \u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u00b7 \u5957\u5185\u7ea690\u33a1 \u00b7 \u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf \u00b7 5\u53f0\u96f6\u8d8a\u98ce\u76d8 + \u6c34\u5730\u6696<\/div>\n  <div>\u6848\u4f8b\u5206\u4eab\u9690\u53bb\u4e1a\u4e3b\u5177\u4f53\u95e8\u724c\u4fe1\u606f\u4e0e\u652f\u4ed8\u91d1\u989d\uff0c\u4ec5\u4f5c\u540c\u6237\u578b\u53c2\u8003\uff1b\u6700\u7ec8\u914d\u7f6e\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e0e\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\u3002<\/div>\n<\/div>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"Article\",\n  \"headline\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\uff5c\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b-\u9f99\u8109\u6696\u901a\",\n  \"description\":\"\u9f99\u8109\u6696\u901a\u4e3a\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u6c64\u5148\u751f90\u33a1\u5957\u4e09\u5b9a\u5236\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u65b9\u6848\uff1aRAS-160\u5168\u53d8\u9891\u4e3b\u673a+\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf+5\u53f0\u96f6\u8d8a\u98ce\u76d8+\u6c34\u5730\u6696\uff0c\u6c34\u7cfb\u7edf\u67d4\u98ce\u4e0d\u5e72\u71e5\u3001\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002\",\n  \"image\":[\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\",\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-dqbyb.jpg\"],\n  \"datePublished\":\"2026-07-18\",\n  \"dateModified\":\"2026-08-01\",\n  \"author\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\"},\n  \"publisher\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\"}},\n  \"locationCreated\":{\"@type\":\"Place\",\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\",\"address\":{\"@type\":\"PostalAddress\",\"addressLocality\":\"\u91d1\u725b\u533a\",\"addressRegion\":\"\u6210\u90fd\u5e02\",\"addressCountry\":\"CN\"}},\n  \"about\":{\"@type\":\"Product\",\"name\":\"\u65e5\u7acb\u6c34\u5885\u9002 RAS-160FPUEN2Q\/M \u5168\u53d8\u9891\u4e24\u8054\u4f9b\"}\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\"@type\":\"Question\",\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u8fd9\u79cd\u5957\u4e09\uff0c\u80fd\u505a\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5b8c\u5168\u53ef\u4ee5\u3002\u672c\u6848\u6c64\u5148\u751f\u5bb6\u5c31\u662f\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u7ea690\u33a1\u5957\u4e09\uff0c\u7a7a\u8c03\u9762\u79ef\u7ea680\u33a1\uff0c\u91c7\u7528 RAS-160 \u5168\u53d8\u9891\u4e3b\u673a + 5\u53f0\u96f6\u8d8a\u98ce\u76d8\uff08\u5ba2\u9910\u5385\u53cc\u98ce\u673a\u76d8\u7ba1\u5206\u533a\u3001\u4e3b\u5367\u4e0e\u4e24\u6b21\u5367\u72ec\u7acb\u6e29\u63a7\uff09+ \u6c34\u5730\u6696\u5171\u7528\u4e3b\u673a\uff0c\u4e00\u5957\u7cfb\u7edf\u8986\u76d6\u5168\u5c4b\u51b7\u6696\u3002\u5957\u4e09\u3001\u5957\u56db\u4e43\u81f3\u5927\u5e73\u5c42\u5747\u53ef\u6309\u9762\u79ef\u4e0e\u5206\u533a\u505a\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b9a\u5236\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u6c34\u7cfb\u7edf\u548c\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u5230\u5e95\u5dee\u5728\u54ea\uff1f\u6c64\u5148\u751f\u4e3a\u4ec0\u4e48\u9009\u6c34\u5885\u9002\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6838\u5fc3\u5dee\u5728\u6362\u70ed\u4ecb\u8d28\u3002\u6c1f\u673a\u51b7\u5a92\u76f4\u63a5\u8fdb\u623f\u95f4\uff0c\u51fa\u98ce7-12\u2103\u53c8\u51b7\u53c8\u5e72\uff0c\u5439\u4e45\u5bb9\u6613\u5934\u75bc\u53e3\u5e72\uff1b\u6c34\u673a\u4e3b\u673a\u5148\u628a\u6c34\u964d\u6e29\u5347\u6e29\uff0c\u518d\u7531\u6c34\u53bb\u623f\u95f4\u6362\u70ed\uff0c\u51fa\u98ce15-20\u2103\u63a5\u8fd1\u81ea\u7136\u98ce\uff0c\u67d4\u548c\u3001\u4e0d\u5e72\u71e5\u3001\u4e0d\u523a\u9aa8\u3002\u6c64\u5148\u751f\u6b64\u524d\u5439\u5b8c\u6c1f\u673a\u5f88\u4e0d\u8212\u670d\uff0c\u6362\u6c34\u7cfb\u7edf\u540e\u4f53\u611f\u6539\u5584\u660e\u663e\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\uff0c\u4f1a\u4e0d\u4f1a\u6c34\u6e29\u4e0d\u7a33\u3001\u4e3b\u673a\u9891\u7e41\u542f\u505c\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e0d\u4f1a\u3002\u65e5\u7acb\u6c34\u5885\u9002\u5b98\u65b9\u6807\u51c6\uff1a\u6700\u5c0f\u6c34\u5bb9\u91cf=\u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf(kW)\u00d72\u3002\u672c\u6848 RAS-160\uff0816kW\uff09\u7cfb\u7edf\u603b\u6c34\u91cf\u7ea676L\uff0c\u800c\u6807\u51c6\u4ec5\u970032L\uff0c\u8d85\u68072.4\u500d\uff0c\u5b8c\u5168\u4e0d\u9700\u8981\u7f13\u51b2\u6c34\u7bb1\u3002\u514d\u6c34\u7bb1\u8ba9\u7cfb\u7edf\u66f4\u7b80\u6d01\u3001\u6545\u969c\u70b9\u66f4\u5c11\u3001\u5f00\u673a\u54cd\u5e94\u66f4\u5feb\uff0c\u662f\u5168\u53d8\u9891\u4e3b\u673a\u7684\u539f\u751f\u6700\u4f18\u89e3\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"90\u33a1\u4e24\u8054\u4f9b\u4ece\u52d8\u6d4b\u5230\u5b8c\u5de5\u5927\u6982\u8981\u591a\u4e45\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6807\u51c6\u5468\u671f\u7ea67-12\u4e2a\u5de5\u4f5c\u65e5\uff08\u89c6\u571f\u5efa\u914d\u5408\uff09\uff1a\u73b0\u573a\u52d8\u6d4b1\u5929\u3001\u65b9\u6848\u51fa\u56fe1-2\u5929\u3001\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u4e0e\u7ba1\u8def\u98ce\u673a\u76d8\u7ba1\u5b89\u88c53-5\u5929\u3001\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe2-3\u5929\u3001\u62bd\u771f\u7a7a\u4fdd\u538b\u4e0e\u53cc\u6a21\u5f0f\u8c03\u8bd51-2\u5929\u3001\u9a8c\u6536\u4ea4\u4ed8\u3002\u9f99\u8109\u6696\u901a\u6309\u7cbe\u5de5\u516b\u5927\u9636\u6bb5\u7ba1\u63a7\uff0c\u9690\u853d\u5de5\u7a0b\u8282\u70b9\u7559\u5b58\u9a8c\u6536\u5355\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u6210\u90fd\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5305\u542b\u54ea\u4e9b\u8d28\u4fdd\uff1f\u514d\u6c34\u7bb1\u540e\u671f\u7ef4\u62a4\u9ebb\u70e6\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e09\u5c42\u4fdd\u969c\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a\u539f\u5382\u8d28\u4fdd + \u9f99\u8109\u5b89\u88c5\u8d28\u4fdd + \u4f1a\u5458\u5ef6\u4fdd\uff1b\u63d0\u4f9b24\u5c0f\u65f6\u5e94\u6025\u4e0a\u95e8\u3002\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\u90e8\u4ef6\u66f4\u5c11\uff0c\u7ef4\u62a4\u66f4\u7b80\u5355\u2014\u2014\u6ca1\u6709\u6c34\u7bb1\u8fd9\u4e2a\u989d\u5916\u90e8\u4ef6\uff0c\u6f5c\u5728\u6545\u969c\u70b9\u66f4\u5c11\uff0c\u65e5\u5e38\u4ec5\u9700\u5b9a\u671f\u6e05\u6d17\u98ce\u673a\u76d8\u7ba1\u6ee4\u7f51\u3001\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e24\u8054\u4f9b\u5730\u6696\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u7701\u591a\u5c11\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u51ac\u5b63\u7528\u4e3b\u673a\u4ea735-45\u2103\u6e29\u6c34\u76f4\u4f9b\u5730\u6696\uff0c\u5168\u53d8\u9891\u6309\u9700\u8f93\u51fa\u3001\u65e0\u71c3\u6c14\u6d88\u8017\uff1b\u6210\u90fd\u540c\u9762\u79ef\u6848\u4f8b\u5bf9\u6807\u663e\u793a\uff0c\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002\u4e14\u4e00\u5957\u4e3b\u673a\u517c\u987e\u590f\u5b63\u5236\u51b7\u4e0e\u51ac\u5b63\u5730\u6696\uff0c\u521d\u6295\u96c6\u4e2d\u4f46\u957f\u671f\u603b\u8d26\u66f4\u7701\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\u548c\u5e26\u7f13\u51b2\u6c34\u7bb1\u65b9\u6848\uff0c\u5206\u522b\u9002\u5408\u4ec0\u4e48\u5bb6\u5ead\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u65e5\u7acb\u6c34\u5885\u9002\u5728\u7cfb\u7edf\u603b\u6c34\u91cf\u6ee1\u8db3\u5b98\u65b9\u6700\u4f4e\u5bb9\u91cf\u8981\u6c42\u65f6\uff0c\u53ef\u91c7\u7528\u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf\uff0c\u7ed3\u6784\u7b80\u6d01\u3001\u6545\u969c\u70b9\u5c11\u3001\u5f00\u673a\u54cd\u5e94\u5feb\uff1b\u82e5\u7ba1\u8def\u5f88\u957f\u3001\u672b\u7aef\u6570\u91cf\u6781\u591a\uff0c\u5219\u5efa\u8bae\u914d\u7f6e\u7f13\u51b2\u6c34\u7bb1\uff0c\u4e24\u79cd\u65b9\u6848\u5747\u5408\u89c4\uff0c\u7ed3\u5408\u6237\u578b\u7ba1\u8def\u5b9e\u9645\u60c5\u51b5\u9009\u578b\u3002\"}}\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"BreadcrumbList\",\n  \"itemListElement\":[\n    {\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9f99\u8109\u6696\u901a\",\"item\":\"https:\/\/longmai-nt.com\"},\n    {\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5ba2\u6237\u6848\u4f8b\u5e93\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=2297\"},\n    {\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b8c\u5de5\u6848\u4f8b\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=2297\"}\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"LocalBusiness\",\n  \"name\":\"\u9f99\u8109\u6696\u901a\",\n  \"image\":[\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\"],\n  \"telephone\":\"028-61649321\",\n  \"priceRange\":\"\uffe5\uffe5\uffe5\",\n  \"address\":[\n    {\"@type\":\"PostalAddress\",\"streetAddress\":\"\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\"addressLocality\":\"\u9ad8\u65b0\u533a\",\"addressRegion\":\"\u6210\u90fd\u5e02\",\"addressCountry\":\"CN\"},\n    {\"@type\":\"PostalAddress\",\"streetAddress\":\"\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a\",\"addressLocality\":\"\u6210\u90fd\",\"addressRegion\":\"\u6210\u90fd\u5e02\",\"addressCountry\":\"CN\"}\n  ],\n  \"areaServed\":[\"\u91d1\u725b\u533a\",\"\u6b66\u4faf\u533a\",\"\u53cc\u6d41\u533a\",\"\u9f99\u6cc9\u9a7f\u533a\",\"\u90eb\u90fd\u533a\",\"\u9ad8\u65b0\u533a\",\"\u6210\u90fd\u5e02\"],\n  \"url\":\"https:\/\/longmai-nt.com\",\n  \"openingHours\":\"09:00-18:00\",\n  \"serviceType\":\"\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u8bbe\u8ba1\u3001\u9500\u552e\u3001\u5b89\u88c5\u4e0e\u552e\u540e\"\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u203a \u5ba2\u6237\u6848\u4f8b\u5e93 \u203a \u6210\u90fd\u91d1\u725b\u533a [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-11713","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=11713\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a \u203a \u5ba2\u6237\u6848\u4f8b\u5e93 \u203a \u6210\u90fd\u91d1\u725b\u533a [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=11713\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-13T15:20:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713\",\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-jgaz-sbcljc.jpg\",\"datePublished\":\"2026-08-27T05:57:25+00:00\",\"dateModified\":\"2026-10-13T15:20:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-jgaz-sbcljc.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-jgaz-sbcljc.jpg\",\"width\":960,\"height\":1280},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11713#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=11713","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a \u203a \u5ba2\u6237\u6848\u4f8b\u5e93 \u203a \u6210\u90fd\u91d1\u725b\u533a [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=11713","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-13T15:20:08+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=11713","url":"https:\/\/longmai-nt.com\/?page_id=11713","name":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=11713#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=11713#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg","datePublished":"2026-08-27T05:57:25+00:00","dateModified":"2026-10-13T15:20:08+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=11713#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=11713"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=11713#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg","width":960,"height":1280},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=11713#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a90\u33a1\u5957\u4e09 \u00b7 \u6c64\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b8c\u5de5\u5b9e\u666f"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11713"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11713\/revisions"}],"predecessor-version":[{"id":14852,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11713\/revisions\/14852"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}