{"id":11797,"date":"2026-08-28T15:37:09","date_gmt":"2026-08-28T07:37:09","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=11797"},"modified":"2026-10-05T20:51:26","modified_gmt":"2026-10-05T12:51:26","slug":"%e6%88%90%e9%83%bd%e9%87%91%e7%89%9b%e5%8c%ba%e9%be%99%e6%b9%96%e6%ba%90%e8%91%9788%e3%8e%a1%e4%b8%89%e5%ae%a4%e4%b8%a4%e5%8e%85%ef%bd%9c%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e4%b8%ad%e5%a4%ae%e7%a9%ba","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=11797","title":{"rendered":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a"},"content":{"rendered":"\n\n<style>\n:root{--lm:#139e74;--lm2:#0c7d5e;--lm3:#0a6b50;--blue:#0a4d8c;--ink:#222;--border:#d8e8e0;--soft:#f3f9f6;--gold:#B8860B}\n*{box-sizing:border-box}\nhtml{scroll-behavior:smooth}\nbody{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;margin:0;color:var(--ink);line-height:1.78;background:#fff}\na{color:var(--blue);text-decoration:none}\nimg{max-width:100%;height:auto}\nsection[id],h2[id],h3[id]{scroll-margin-top:80px}\ntable{width:100%;border-collapse:collapse;font-size:.86rem;margin:10px 0}\nth,td{border:1px solid var(--border);padding:9px 11px;text-align:left;vertical-align:top}\nth{background:var(--soft);color:var(--lm3);font-weight:700}\ntr:nth-child(even) td{background:#fafdfb}\n.lm-hero{position:relative;min-height:360px;background:linear-gradient(135deg,var(--lm3),var(--lm));display:flex;flex-direction:column;justify-content:center;align-items:center;color:#fff;text-align:center;padding:46px 20px}\n.lm-hero h1{font-size:1.35rem;margin:8px 0 12px;font-weight:800;line-height:1.45;max-width:840px}\n.lm-hero .lm-sub{font-size:.9rem;opacity:.92;max-width:700px;line-height:1.7}\n.lm-hero-info{display:flex;flex-wrap:wrap;gap:10px 22px;margin-top:16px}\n.lm-hero-info .lm-it{min-width:84px}\n.lm-hero-info .lm-lab{font-size:.72rem;opacity:.85}\n.lm-hero-info .lm-val{font-size:.98rem;font-weight:700}\n.lm-hero .lm-update{font-size:.72rem;opacity:.85;margin-top:12px}\n.lm-steps{position:sticky;top:0;z-index:100;background:var(--lm2);display:flex;gap:6px;overflow-x:auto;padding:8px 12px;box-shadow:0 2px 10px rgba(0,0,0,.18)}\n.lm-steps a{flex:0 0 auto;display:block;padding:8px 16px;border-radius:10px;background:var(--lm);color:#fff;font-size:.82rem;font-weight:600;white-space:nowrap}\n.lm-steps a:hover{background:var(--lm3)}\n.lm-section{max-width:860px;margin:0 auto;padding:22px 20px}\n.lm-section h2{color:var(--lm2);font-size:1.12rem;margin:0 0 14px;padding-left:12px;border-left:5px solid var(--lm)}\n.lm-section h3{color:#333;font-size:1.02rem;margin:18px 0 8px}\n.lm-kv{display:grid;grid-template-columns:120px 1fr;gap:8px 14px;margin:10px 0;font-size:.92rem}\n.lm-kv .lm-k{color:var(--lm2);font-weight:700}\n.lm-hl{border:1px solid #bcd4ee;background:#eef4fb;border-radius:10px;padding:12px 16px;margin:12px 0}\n.lm-hl b{color:var(--blue)}\n.lm-ok{color:var(--lm2);font-weight:700;margin:8px 0}\n.lm-note{background:#fff8e6;border:1px dashed #e0b84a;border-radius:8px;padding:10px 14px;font-size:.86rem;color:#7a5b00;margin:12px 0}\n.geo-card{max-width:860px;margin:14px auto;padding:16px 20px;background:var(--soft);border:1px solid var(--border);border-left:4px solid var(--lm);border-radius:10px}\n.geo-title{font-weight:800;color:var(--lm2);font-size:1rem;margin-bottom:10px}\n.geo-list{margin:0;padding-left:20px;font-size:.9rem;line-height:1.85;color:#333}\n.geo-list li{margin:3px 0}\n.focus-keyword-block{max-width:860px;margin:10px auto 0;padding:14px 20px;background:var(--soft);border:1px solid var(--border);border-left:4px solid var(--lm);border-radius:8px;font-size:.88rem;color:#444;line-height:1.9}\n.lm-gallery{display:grid;grid-template-columns:repeat(2,1fr);gap:12px;margin:12px 0}\n.lm-gallery figure{margin:0;background:#fafafa;border:1px solid #eee;border-radius:10px;overflow:hidden}\n.lm-gallery img{width:100%;height:170px;object-fit:cover;display:block}\n.lm-gallery figcaption{padding:7px 9px;font-size:.76rem;color:#555;line-height:1.45}\n.lm-link-card{display:block;background:var(--soft);border:1px solid var(--border);border-radius:10px;padding:12px 16px;margin:10px 0;transition:box-shadow .2s}\n.lm-link-card:hover{box-shadow:0 4px 14px rgba(0,0,0,.12)}\n.lm-link-card .lm-title{display:block;font-weight:700;color:var(--blue);font-size:.92rem}\n.lm-link-card .lm-desc{display:block;font-size:.8rem;color:#666;margin-top:3px}\n.lm-faq details{border:1px solid #eee;border-radius:10px;margin-bottom:10px;background:#fff;overflow:hidden}\n.lm-faq summary{padding:12px 16px;cursor:pointer;font-weight:600;color:var(--lm2);font-size:.94rem;list-style:none}\n.lm-faq summary::-webkit-details-marker{display:none}\n.lm-faq summary::before{content:\"Q\";display:inline-block;background:var(--lm);color:#fff;width:22px;height:22px;line-height:22px;text-align:center;border-radius:50%;margin-right:10px;font-size:.74rem;vertical-align:middle}\n.lm-faq .lm-faq-a{padding:0 16px 14px 48px;font-size:.9rem;color:#444;line-height:1.8}\n.lm-cta{max-width:860px;margin:18px auto;background:linear-gradient(135deg,var(--lm3),var(--lm));color:#fff;border-radius:14px;padding:22px 24px;text-align:center}\n.lm-cta h3{color:#fff;margin:0 0 8px;font-size:1.1rem}\n.lm-cta p{margin:6px 0;font-size:.92rem}\n.lm-cta a{color:#fff;text-decoration:underline;font-weight:700}\n.lm-cta .lm-btn{display:inline-block;margin-top:10px;background:#fff;color:var(--lm2);padding:9px 22px;border-radius:999px;font-weight:700;text-decoration:none}\n.lm-foot{max-width:860px;margin:0 auto;padding:16px 20px;font-size:.8rem;color:#888;border-top:1px solid #eee;line-height:1.7}\n@media(max-width:560px){.lm-hero h1{font-size:1.05rem}.lm-gallery{grid-template-columns:1fr}}\n<\/style>\n\n<nav style=\"max-width:860px;margin:0 auto;padding:10px 20px 0;font-size:.78rem;color:#999\"><a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" rel=\"noopener noreferrer\">\u9f99\u8109\u6696\u901a<\/a> \u203a <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener noreferrer\">\u5ba2\u6237\u6848\u4f8b\u5e93<\/a> \u203a <a href=\"https:\/\/longmai-nt.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">\u9f99\u6e56\u6e90\u8457\u00b7G\u5973\u58eb\uff08\u8212\u4eab180\u4e00\u62d6\u56db+\u83f2\u65af\u66fc\u5730\u6696\uff09<\/a><\/nav>\n\n<div class=\"lm-hero\">\n  <div style=\"font-size:.82rem;letter-spacing:2px;opacity:.92\">\u5b8c\u5de5\u6848\u4f8b\u5206\u4eab \u00b7 \u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457 \u00b7 \u65e5\u7acb\u8212\u4eab180\u4e00\u62d6\u56db \u00b7 \u83f2\u65af\u66fc\u5730\u6696<\/div>\n  <h1>\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a<\/h1>\n  <div class=\"lm-sub\">\u7a7a\u8c03\u53ea\u5236\u51b7\u00b7\u51b7\u91cf\u505a\u5927\u5e94\u5bf9\u897f\u6652\u6015\u70ed \uff5c \u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\u5730\u6696\u00b7\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u7eaf\u94dd\u53cd\u5c04\u819c\u5347\u7ea7 \uff5c \u65e5\u7acb\u6388\u674322\u5e74\u00b7\u6210\u90fd\u53cc\u95e8\u5e97\u552e\u540e\u65e0\u5fe7<\/div>\n  <div class=\"lm-hero-info\">\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u5ba2\u6237<\/div><div class=\"lm-val\">G\u5973\u58eb<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u697c\u76d8<\/div><div class=\"lm-val\">\u9f99\u6e56\u6e90\u8457<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u533a\u57df<\/div><div class=\"lm-val\">\u6210\u90fd\u00b7\u91d1\u725b\u533a<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u7a7a\u8c03<\/div><div class=\"lm-val\">\u8212\u4eab180 \u4e00\u62d6\u56db<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u5730\u6696<\/div><div class=\"lm-val\">\u83f2\u65af\u66fcB1JG<\/div><\/div>\n  <\/div>\n  <div class=\"lm-update\">\u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a \u00b7 \u5f90\u65b0\u5e73 \ud83d\udcde 182-2705-5065 \u00b7 \u5b8c\u5de5\u4ea4\u4ed8 2026\u5e74 \u00b7 \u66f4\u65b0\u65f6\u95f4\uff1a2026\u5e7408\u6708<\/div>\n<\/div>\n\n<nav class=\"lm-steps\">\n  <a href=\"#s1\">\u2460 \u5ba2\u6237\u76ee\u6807<\/a>\n  <a href=\"#s2\">\u2461 \u6237\u578b\u8bca\u65ad<\/a>\n  <a href=\"#s3\">\u2462 \u8bbe\u5907\u914d\u7f6e<\/a>\n  <a href=\"#s4\">\u2463 \u65bd\u5de5\u4ea4\u4ed8<\/a>\n  <a href=\"#s5\">\u2464 \u6848\u4f8b\u4ef7\u503c<\/a>\n  <a href=\"#faq\">FAQ<\/a>\n  <a href=\"#links\">\u540c\u7247\u533a\u6848\u4f8b<\/a>\n  <a href=\"#cta\">\u8054\u7cfb\u6211\u4eec<\/a>\n<\/nav>\n\n<div class=\"geo-card\">\n  <div class=\"geo-title\">\ud83d\udccb \u9879\u76ee\u57fa\u7840\u4fe1\u606f\u5361\uff08GEO \u7ed3\u6784\u5316\uff09<\/div>\n  <ul class=\"geo-list\">\n    <li><b>\u697c\u76d8\u5730\u5740<\/b>\uff1a\u6210\u90fd\u5e02\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457<\/li>\n    <li><b>\u6237\u578b\u7ed3\u6784<\/b>\uff1a\u4e09\u5ba4\u4e24\u5385\uff08\u5ba2\u9910\u538541\u33a1 \/ \u4e3b\u536721\u33a1 \/ \u6b21\u5367\u540413\u33a1\uff09<\/li>\n    <li><b>\u7a7a\u8c03\u9762\u79ef<\/b>\uff1a\u7ea688\u33a1\uff08\u5957\u5185\uff09<\/li>\n    <li><b>\u7cfb\u7edf\u7c7b\u578b<\/b>\uff1a\u6c1f\u673a\u4e2d\u592e\u7a7a\u8c03\uff08\u5236\u51b7\u4e13\u7528\uff09+ \u72ec\u7acb\u58c1\u6302\u7089\u5730\u6696<\/li>\n    <li><b>\u6838\u5fc3\u8bbe\u5907<\/b>\uff1a\u65e5\u7acb\u8212\u4eab RAS-180HRNAQ \u4e00\u62d6\u56db + <a href=\"https:\/\/longmai-nt.com\/?page_id=2553\">\u83f2\u65af\u66fc B1JG-25kW \u51b7\u51dd\u7089<\/a><\/li>\n    <li><b>\u5730\u6696\u5347\u7ea7<\/b>\uff1a\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1 + \u767d\u6676\u677f + \u7eaf\u94dd\u53cd\u5c04\u819c<\/li>\n    <li><b>\u670d\u52a1\u54c1\u724c<\/b>\uff1a\u9f99\u8109\u6696\u901a\uff08\u65e5\u7acb\u6388\u674322\u5e74\uff09<\/li>\n    <li><b>\u9002\u5408\u4eba\u7fa4<\/b>\uff1a\u5e38\u4f4f3-4\u4eba\u3001\u6015\u70ed\u5bb6\u5ead\u3001\u897f\u6652\u6237\u578b<\/li>\n  <\/ul>\n<\/div>\n\n<div class=\"focus-keyword-block\">\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u6848\u4f8b\uff0c\u65e5\u7acb\u8212\u4eabRAS-180\u5355\u98ce\u6247\u4e00\u62d6\u56db\u4e2d\u592e\u7a7a\u8c03\u53ea\u5236\u51b7\uff0c\u5ba2\u9910\u538590\u578b\u5927\u51b7\u91cf\u5185\u673a\u5e94\u5bf9\u897f\u6652\u6015\u70ed\uff0c\u4e3b\u536740\u578b\u3001\u4e24\u6b21\u5367\u540425\u578b\uff1b\u83f2\u65af\u66fcB1JG-25kW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u3001\u767d\u6676\u677f\u3001\u7eaf\u94dd\u53cd\u5c04\u819c\u8f85\u6750\u5347\u7ea7\uff1b\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u674322\u5e74\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u4e0e\u6237\u578b\u65b9\u6848\u51fa\u5177\uff0c\u6210\u90fd\u53cc\u95e8\u5e97\u552e\u540e\u65e0\u5fe7\uff0c\u8212\u9002\u5bb6\u5c45\u4e00\u7ad9\u5f0f\u843d\u5730\u3002<\/div>\n\n<section class=\"lm-section\" id=\"s1\">\n  <h2>\u4e00\u3001\u5ba2\u6237\u6210\u529f\u76ee\u6807\u4e0e\u6237\u578b\u8bca\u65ad<\/h2>\n  <h3>1.1 \u5bb6\u5ead\u7ed3\u6784\u4e0e\u6838\u5fc3\u8bc9\u6c42<\/h3>\n  <p>\u4e1a\u4e3bG\u5973\u58eb\u4e00\u5bb6\u5e38\u4f4f3-4\u4eba\uff1a\u4e24\u53e3\u5b50\u52a0\u4e00\u4e2a\u5c0f\u670b\u53cb\uff0c\u5076\u5c14\u7236\u6bcd\u4f1a\u8fc7\u6765\u5c0f\u4f4f\u3002\u5168\u5bb6\u4eba\u90fd\u4e0d\u8010\u70ed\uff0c\u5bf9\u5236\u51b7\u901f\u5ea6\u548c\u4f4e\u6e29\u4f53\u611f\u8981\u6c42\u660e\u663e\u9ad8\u4e8e\u4e00\u822c\u5bb6\u5ead\uff0c\u6240\u4ee5\u7a7a\u8c03\u51b7\u91cf\u6574\u4f53\u505a\u5f97\u504f\u5927\u3002\u5bb6\u91cc\u4eb2\u621a\u65e9\u5c31\u5728\u7528\u65e5\u7acb\uff0c\u7528\u4e0b\u6765\u5f88\u8212\u670d\uff0c\u5bf9\u65e5\u7acb\u8fd9\u4e2a\u8001\u54c1\u724c\u7684\u54c1\u8d28\u548c\u6280\u672f\u5370\u8c61\u4e00\u76f4\u6bd4\u8f83\u597d\uff0c\u8fd9\u4e5f\u662f\u6700\u7ec8\u9009\u62e9\u65e5\u7acb\u7684\u91cd\u8981\u539f\u56e0\u3002\u9009\u62e9\u9f99\u8109\uff0c\u5219\u770b\u91cd\u516c\u53f8\u7684\u6574\u4f53\u5b9e\u529b\u3001\u670d\u52a1\u4e0e\u552e\u540e\u90fd\u9760\u8c31\u3002<\/p>\n  <h3>1.2 \u897f\u6652\u6237\u578b\u4e0e\u9ad8\u51b7\u91cf\u8bbe\u8ba1<\/h3>\n  <p>\u5ba2\u9910\u538541\u33a1\u4e14\u671d\u897f\uff0c\u5348\u540e\u897f\u6652\u660e\u663e\uff0c\u662f\u6574\u5957\u623f\u578b\u51b7\u8d1f\u8377\u6700\u9ad8\u7684\u533a\u57df\u3002\u7ed3\u5408\u91d1\u725b\u533a\u9ad8\u5c42\u4f4f\u5b85\u590f\u5b63\u897f\u6652\u3001\u51ac\u5b63\u6e7f\u51b7\u7684\u7279\u70b9\uff0c\u672c\u5957\u65b9\u6848\u5728\u8d1f\u8377\u53d6\u503c\u4e0a\u5145\u5206\u8003\u8651\u4e86\u56f4\u62a4\u7ed3\u6784\u4e0e\u671d\u5411\u56e0\u7d20\uff0c\u5ba2\u9910\u5385\u5355\u4f4d\u51b7\u91cf\u4e0a\u6d6e\u5230\u7ea6219W\/\u33a1\uff0c\u5168\u5c4b\u51b7\u91cf\u7559\u6709\u5197\u4f59\uff0c\u786e\u4fdd\u9ad8\u5cf0\u65f6\u6bb5\u4e5f\u80fd\u5feb\u901f\u964d\u6e29\u3001\u6e29\u5ea6\u5747\u5300\u3002<\/p>\n  <div class=\"lm-hl\">\ud83c\udfaf <b>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/b>\uff1a\u590f\u5929\u518d\u70ed\u4e5f\u4e0d\u6015\uff0c\u897f\u6652\u5ba2\u9910\u5385\u80fd\u5feb\u901f\u51c9\u4e0b\u6765\uff1b\u51ac\u5929\u5730\u6696\u8212\u670d\u3001\u8fd0\u884c\u7701\u5fc3\uff1b\u54c1\u724c\u9760\u8c31\u3001\u516c\u53f8\u552e\u540e\u7a33\uff0c\u4f4f\u5f97\u5b89\u5fc3\u3002<\/div>\n<\/section>\n\n<section class=\"lm-section\" id=\"s2\">\n  <h2>\u4e8c\u3001\u65b9\u6848\u8bbe\u8ba1\u4e0e\u8bbe\u5907\u914d\u7f6e<\/h2>\n  <h3>2.1 \u7a7a\u8c03\u7cfb\u7edf\uff08\u53ea\u5236\u51b7\uff09<\/h3>\n  <p>\u91c7\u7528\u65e5\u7acb\u8212\u4eab RAS-180HRNAQ \u5355\u98ce\u6247\u5916\u673a\uff0c\u4e00\u62d6\u56db\uff1a\u5ba2\u9910\u538590\u578b\u3001\u4e3b\u536740\u578b\u3001\u4e24\u6b21\u5367\u540425\u578b\u3002\u672c\u6237\u7a7a\u8c03\u5b9a\u4f4d\u4e8e<b>\u590f\u5b63\u5236\u51b7\u4e13\u7528<\/b>\uff0c\u51ac\u5b63\u91c7\u6696\u7531\u83f2\u65af\u66fc\u5730\u6696\u72ec\u7acb\u627f\u62c5\uff0c\u5206\u5de5\u6e05\u6670\u3001\u4e92\u4e0d\u5e72\u6270\u3002\u8212\u4eab\u4f5c\u4e3a\u65e5\u7acb\u54c1\u8d28\u5e73\u53f0\uff0c\u9759\u97f3\u4e0e\u8282\u80fd\u8868\u73b0\u66f4\u4f18\uff0c\u5e76\u4fdd\u7559\u5236\u70ed\u80fd\u529b\u4f5c\u4e3a\u6781\u7aef\u5929\u6c14\u5197\u4f59\u3002<\/p>\n  <h3>2.2 \u5730\u6696\u7cfb\u7edf\uff08\u83f2\u65af\u66fc + \u5347\u7ea7\u8f85\u6750\uff09<\/h3>\n  <p>\u91c7\u6696\u70ed\u6e90\u4e3a\u83f2\u65af\u66fc B1JG-25kW \u51b7\u51dd\u5f0f\u58c1\u6302\u7089\uff0c\u5339\u914d\u9f99\u8109\u516c\u53f8\u5e02\u573a\u901a\u914d\u578b\u8f85\u6750\uff1b\u5e76\u5728\u6807\u51c6\u57fa\u7840\u4e0a\u505a\u4e09\u9879\u5347\u7ea7\uff1a<b>\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1<\/b>\uff08\u963b\u9694\u6c27\u6c14\u6e17\u5165\u3001\u51cf\u7f13\u7cfb\u7edf\u6c27\u5316\u7ed3\u57a2\uff09\u3001<b>\u767d\u6676\u677f<\/b>\uff08\u4fdd\u6e29\u4f18\u4e8e\u666e\u901a\u6324\u5851\u677f\u3001\u51cf\u5c11\u5411\u4e0b\u70ed\u635f\uff09\u3001<b>\u7eaf\u94dd\u53cd\u5c04\u819c<\/b>\uff08\u53cd\u5c04\u70ed\u8f90\u5c04\u3001\u63d0\u5347\u5411\u4e0a\u5f97\u70ed\u6548\u7387\uff09\u3002\u4e09\u9879\u5347\u7ea7\u5171\u540c\u8ba9\u5730\u6696\u66f4\u8282\u80fd\u3001\u66f4\u8010\u4e45\u3002<\/p>\n  <h3>2.3 \u8bbe\u5907\u914d\u7f6e\u6e05\u5355<\/h3>\n  <table>\n    <tbody><tr><th>\u7a7a\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u8bbe\u5907<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <tr><td>\u5ba2\u9910\u5385<\/td><td>41\u33a1<\/td><td>\u65e5\u7acb\u8212\u4eab 90\u578b \u5185\u673a<\/td><td>\u897f\u6652\u00b7\u5927\u51b7\u91cf<\/td><\/tr>\n    <tr><td>\u4e3b\u5367<\/td><td>21\u33a1<\/td><td>\u65e5\u7acb\u8212\u4eab 40\u578b \u5185\u673a<\/td><td>\u9759\u97f3\u4f18\u5148<\/td><\/tr>\n    <tr><td>\u6b21\u53671<\/td><td>13\u33a1<\/td><td>\u65e5\u7acb\u8212\u4eab 25\u578b \u5185\u673a<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u6b21\u53672<\/td><td>13\u33a1<\/td><td>\u65e5\u7acb\u8212\u4eab 25\u578b \u5185\u673a<\/td><td>\u2014<\/td><\/tr>\n    <tr><td>\u5916\u673a<\/td><td>\u2014<\/td><td>\u65e5\u7acb\u8212\u4eab RAS-180HRNAQ \u5355\u98ce\u6247<\/td><td>\u4e00\u62d6\u56db<\/td><\/tr>\n    <tr><td>\u5730\u6696<\/td><td>\u7ea688\u33a1<\/td><td>\u83f2\u65af\u66fc B1JG-25kW \u51b7\u51dd\u7089 + \u9f99\u8109\u901a\u914d\u8f85\u6750<\/td><td>\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\/\u767d\u6676\u677f\/\u7eaf\u94dd\u53cd\u5c04\u819c<\/td><\/tr>\n  <\/tbody><\/table>\n  <h3>2.4 \u51b7\u91cf\u8d1f\u8377\u4e0e\u8d85\u914d\u7387<\/h3>\n  <p>\u5ba4\u5185\u673a\u603b\u51b7\u91cf 9.0+4.0+2.5+2.5 = 18.0kW\uff0c\u5916\u673a RAS-180 \u989d\u5b9a\u7ea618.0kW\uff0c<b>\u8d85\u914d\u7387\u7ea6100%<\/b>\uff0c\u843d\u5728\u884c\u4e1a\u5efa\u8bae\u768450%\u2013130%\u5408\u89c4\u533a\u95f4\uff0c\u65e2\u6ee1\u8db3\u9ad8\u5cf0\u5236\u51b7\uff0c\u53c8\u907f\u514d\u5916\u673a\u957f\u671f\u4f4e\u8d1f\u8377\u8fd0\u884c\u3002<\/p>\n  <div class=\"lm-note\">\ud83d\udcd0 \u8bbe\u8ba1\u4f9d\u636e\uff1a\u7a7a\u8c03\u51b7\u8d1f\u8377\u53c2\u7167\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB 50736\u20112012 \u8ba1\u7b97\u539f\u5219\uff0c\u5730\u6696\u76d8\u7ba1\u53c2\u7167\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142\u20112012\uff0c\u5e76\u7ed3\u5408\u672c\u6237\u671d\u5411\u3001\u7a97\u5899\u6bd4\u4e0e\u897f\u6652\u5b9e\u9645\u5355\u72ec\u6838\u7b97\uff0c\u4e0d\u5957\u6a21\u677f\u53d6\u503c\u3002<\/div>\n<\/section>\n\n<section class=\"lm-section\" id=\"s3\">\n  <h2>\u4e09\u3001\u65bd\u5de5\u5de5\u827a\u4e0e\u9a8c\u6536\u6807\u51c6<\/h2>\n  <h3>3.1 \u6c1f\u673a\u7a7a\u8c03\u65bd\u5de5\u8981\u70b9<\/h3>\n  <p>\u51b7\u5a92\u7ba1\u8def\u5168\u7a0b<b>\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5<\/b>\uff0c\u675c\u7edd\u6c27\u5316\u76ae\u5835\u585e\uff1b\u710a\u63a5\u5b8c\u6210\u540e\u505a\u6c14\u5bc6\u6027\u4fdd\u538b\u68c0\u6f0f\uff1b\u5ba4\u5185\u673a\u540a\u88c5\u4fdd\u8bc1\u6c34\u5e73\u5ea6\u5e76\u9884\u7559\u51b7\u51dd\u6c34\u6392\u6c34\u5761\u5ea6\uff0c\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u5b89\u88c5\u89c4\u8303\uff0c\u907f\u514d\u540e\u671f\u6ef4\u6c34\u3002<\/p>\n  <h3>3.2 \u5730\u6696\u65bd\u5de5\u8981\u70b9<\/h3>\n  <p>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u540e\u505a<b>\u6c34\u538b\u8bd5\u9a8c\uff080.6MPa \u4fdd\u538b24\u5c0f\u65f6\uff09<\/b>\u786e\u8ba4\u65e0\u6e17\u6f0f\uff1b\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u7aef\u6b63\u3001\u56de\u8def\u6807\u8bc6\u6e05\u6670\uff1b\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u91c7\u7528\u4e13\u7528\u70ed\u7194\u8fde\u63a5\uff0c\u767d\u6676\u677f\u6ee1\u94fa\u3001\u7eaf\u94dd\u53cd\u5c04\u819c\u642d\u63a5\u4e25\u5bc6\u3002\u5730\u6696\u76d8\u7ba1\u8bbe\u8ba1\u4e0e\u65bd\u5de5\u540c\u65f6\u53c2\u7167\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142\u20112012\u3002<\/p>\n  <div class=\"lm-ok\">\u2705 \u9f99\u8109\u516b\u5927\u9636\u6bb5\u9a8c\u6536\uff08\u8bbe\u8ba1\u4ea4\u5e95\u2192\u8f85\u6750\u8fdb\u573a\u2192\u9690\u853d\u5de5\u7a0b\u2192\u5206\u9879\u8c03\u8bd5\u2192\u6574\u4f53\u8054\u8c03\u2192\u76d1\u7406\u590d\u6838\u2192\u5ba2\u6237\u9a8c\u6536\u2192\u552e\u540e\u5efa\u6863\uff09\uff0c\u672c\u6237\u5173\u952e\u56db\u9879\u5982\u4e0b\uff1a<\/div>\n  <table>\n    <tbody><tr><th>\u5e8f\u53f7<\/th><th>\u9a8c\u6536\u9879<\/th><th>\u6807\u51c6<\/th><\/tr>\n    <tr><td>1<\/td><td>\u51b7\u5a92\u7ba1\u8def\u710a\u63a5\u4e0e\u4fdd\u538b<\/td><td>\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff0c\u6c14\u5bc6\u6027\u8bd5\u9a8c\u5408\u683c\u65e0\u6cc4\u6f0f<\/td><\/tr>\n    <tr><td>2<\/td><td>\u5ba4\u5185\u673a\u540a\u88c5<\/td><td>\u6c34\u5e73\u5ea6\u8fbe\u6807\uff0c\u51b7\u51dd\u6c34\u6392\u6c34\u5761\u5ea6\u6b63\u786e\u3001\u65e0\u5012\u5761<\/td><\/tr>\n    <tr><td>3<\/td><td>\u5730\u6696\u76d8\u7ba1\u6c34\u538b<\/td><td>0.6MPa \u4fdd\u538b24h\uff0c\u538b\u964d\u5728\u5141\u8bb8\u8303\u56f4<\/td><\/tr>\n    <tr><td>4<\/td><td>\u5206\u96c6\u6c34\u5668\u4e0e\u8054\u52a8\u8c03\u8bd5<\/td><td>\u56de\u8def\u6e05\u6670\u3001\u7cfb\u7edf\u8054\u8c03\u6b63\u5e38<\/td><\/tr>\n  <\/tbody><\/table>\n<\/section>\n\n<section class=\"lm-section\" id=\"s4\">\n  <h2>\u56db\u3001\u5b8c\u5de5\u5b9e\u666f\u4e0e\u5de5\u827a\u7ec6\u8282<\/h2>\n  <p>\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6807\u51c6\u65bd\u5de5\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff0c\u5f85\u8865\u62cd\u540e\u66ff\u6362\uff09\uff1a<\/p>\n  <div class=\"lm-gallery\">\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\"><figcaption>\u9f99\u8109\u6696\u901a\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-danqibaohuhanjie.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u51b7\u5a92\u7ba1\u8def\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u540c\u6807\u51c6\u5de5\u827a\"><figcaption>\u9f99\u8109\u6696\u901a\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u51b7\u5a92\u7ba1\u8def\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u540c\u6807\u51c6\u5de5\u827a<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-guanluanzhuang.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u51b7\u5a92\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u540c\u6807\u51c6\u5de5\u827a\"><figcaption>\u9f99\u8109\u6696\u901a\u51b7\u5a92\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u540c\u6807\u51c6\u5de5\u827a<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sanguanzhineijianzhuang.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5ba4\u5185\u673a\u540a\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eabDC\u8584\u578b\u6807\u51c6\u5185\u673a\u540c\u6807\u51c6\u5de5\u827a\"><figcaption>\u9f99\u8109\u6696\u901a\u5ba4\u5185\u673a\u540a\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eabDC\u8584\u578b\u6807\u51c6\u5185\u673a\u540c\u6807\u51c6\u5de5\u827a<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-lengningqishengjiang.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u51b7\u51dd\u6c34\u7ba1\u4e0e\u63d0\u5347\u6cf5\u5b89\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u540c\u6807\u51c6\u5de5\u827a\"><figcaption>\u9f99\u8109\u6696\u901a\u51b7\u51dd\u6c34\u7ba1\u4e0e\u63d0\u5347\u6cf5\u5b89\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u540c\u6807\u51c6\u5de5\u827a<\/figcaption><\/figure>\n  <\/div>\n  <div class=\"lm-note\">\ud83d\udcf7 \u672c\u6848\u7a7a\u8c03\u4e0e\u5730\u6696\u65bd\u5de5\u5b9e\u666f\u7167\u7247\u5f85\u5b8c\u5de5\u540e\u8865\u62cd\u5f52\u6863\uff1b\u56fe\u4e2d\u4e3a\u9f99\u8109\u540c\u6807\u51c6\u5de5\u827a\u793a\u610f\uff0c\u5c55\u73b0\u8f85\u6750\u8fdb\u573a\u3001\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u3001\u7ba1\u8def\u5b89\u88c5\u3001\u5ba4\u5185\u673a\u540a\u88c5\u3001\u51b7\u51dd\u6c34\u7cfb\u7edf\u7b49\u5173\u952e\u8282\u70b9\u3002<\/div>\n<\/section>\n\n<section class=\"lm-section\" id=\"s5\">\n  <h2>\u4e94\u3001\u4e1a\u4e3b\u53cd\u9988\u4e0e\u4f7f\u7528\u4f53\u611f<\/h2>\n  <p>\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6237\u578b\u5b8c\u5de5\u6848\u4f8b\u5bf9\u6807\u4f53\u611f\uff0c\u672c\u6237\u5b9e\u9645\u6548\u679c\u4ee5\u5b8c\u5de5\u8c03\u8bd5\u540e\u7684\u73b0\u573a\u5b9e\u6d4b\u4e3a\u51c6\u3002<\/p>\n  <h3>5.1 \u5236\u51b7\u4f53\u611f\uff08\u897f\u6652\u5e94\u5bf9\uff09<\/h3>\n  <p>\u540c\u6237\u578b\u897f\u6652\u5ba2\u9910\u5385\u6848\u4f8b\u5bf9\u6807\uff1a\u5f00\u673a\u540e\u7ea615\u201320\u5206\u949f\u5ba4\u6e29\u964d\u81f3\u8bbe\u5b9a\u503c\uff0c\u897f\u6652\u5899\u9762\u4e00\u4fa7\u6e29\u5ea6\u4e0e\u5ba4\u5185\u533a\u57df\u6e29\u5dee\u660e\u663e\u7f29\u5c0f\uff1b\u8212\u4eab\u5185\u673a\u4f4e\u98ce\u6863\u8fd0\u884c\u566a\u97f3\u4f4e\uff0c\u591c\u95f4\u4f7f\u7528\u4e0d\u6270\u7720\u3002\u5177\u4f53\u4ee5\u672c\u6237\u8c03\u8bd5\u540e\u5b9e\u6d4b\u4e3a\u51c6\u3002<\/p>\n  <h3>5.2 \u5730\u6696\u4f53\u611f<\/h3>\n  <p>\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u642d\u914d\u5347\u7ea7\u8f85\u6750\uff0c\u5730\u6696\u5347\u6e29\u5e73\u7a33\u3001\u5730\u9762\u6e29\u5ea6\u5747\u5300\uff1b\u767d\u6676\u677f\u4e0e\u7eaf\u94dd\u53cd\u5c04\u819c\u51cf\u5c11\u5411\u4e0b\u70ed\u635f\uff0c\u4f53\u611f\u66f4\"\u6696\u811a\u4e0d\u71e5\"\u3002\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c<b>\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u6bcf\u6237\u627f\u8bfa<\/b>\u3002<\/p>\n  <h3>5.3 \u4e1a\u4e3b\u9009\u8d2d\u53cd\u9988<\/h3>\n  <p>\u4e1a\u4e3bG\u5973\u58eb\u9009\u8d2d\u9636\u6bb5\u53cd\u9988\uff08\u9009\u8d2d\u9636\u6bb5\uff0c\u5c1a\u672a\u5165\u4f4f\u4f7f\u7528\uff09\uff1a\u5bb6\u91cc\u4eb2\u621a\u65e9\u5c31\u5728\u7528\u65e5\u7acb\uff0c\u7528\u4e0b\u6765\u5f88\u8212\u670d\uff0c\u6240\u4ee5\u5bf9\u65e5\u7acb\u8fd9\u4e2a\u8001\u54c1\u724c\u7684\u5370\u8c61\u4e00\u76f4\u6bd4\u8f83\u597d\uff1b\u4e00\u5bb6\u4eba\u90fd\u4e0d\u8010\u70ed\u3001\u5ba2\u9910\u5385\u53c8\u6709\u897f\u6652\uff0c\u7a7a\u8c03\u51b7\u91cf\u7279\u610f\u505a\u5927\u4e86\u4e9b\u3002\u5bf9\u6bd4\u8fc7\u7f8e\u7684\u3001\u683c\u529b\u8fd9\u4e9b\u56fd\u4ea7\u54c1\u724c\uff0c\u7efc\u5408\u4e0b\u6765\u8fd8\u662f\u66f4\u8ba4\u65e5\u7acb\u7684\u54c1\u8d28\u548c\u6280\u672f\uff0c\u8212\u4eab\u8fd9\u6863\u6027\u4ef7\u6bd4\u4e5f\u9ad8\u3001\u4ef7\u683c\u5408\u7406\u3002\u9009\u9f99\u8109\uff0c\u4e3b\u8981\u770b\u4e2d\u516c\u53f8\u7684\u6574\u4f53\u5b9e\u529b\u3001\u670d\u52a1\u548c\u552e\u540e\u90fd\u9760\u8c31\uff0c\u8ba9\u4eba\u653e\u5fc3\u3002<\/p>\n  <div class=\"lm-note\">\u26a0\ufe0f \u4ee5\u4e0a\u4e3a\u9009\u8d2d\u9636\u6bb5\u771f\u5b9e\u53cd\u9988\uff0c\u975e\u5165\u4f4f\u540e\u4f7f\u7528\u6548\u679c\u627f\u8bfa\uff1b\u672c\u6237\u5b9e\u9645\u5236\u51b7\/\u91c7\u6696\u4f53\u611f\u4ee5\u5b8c\u5de5\u8c03\u8bd5\u540e\u73b0\u573a\u5b9e\u6d4b\u4e3a\u51c6\u3002<\/div>\n<\/section>\n\n<section class=\"lm-section\" id=\"faq\">\n  <h2>\u516d\u3001\u5e38\u89c1\u95ee\u9898 FAQ<\/h2>\n  <div class=\"lm-faq\">\n    <details><summary>\u5ba2\u9910\u538541\u33a1\uff0c\u4e3a\u4ec0\u4e48\u752890\u578b\u5927\u51b7\u91cf\u5185\u673a\u800c\u4e0d\u662f\u66f4\u5c0f\u7684\uff1f<\/summary><div class=\"lm-faq-a\">\u672c\u6237\u5ba2\u9910\u538541\u33a1\u4e14\u671d\u897f\u3001\u5348\u540e\u897f\u6652\u660e\u663e\uff0c\u4e00\u5bb6\u4eba\u90fd\u4e0d\u8010\u70ed\uff0c\u5bf9\u5236\u51b7\u901f\u5ea6\u548c\u4f4e\u6e29\u4f53\u9a8c\u8981\u6c42\u9ad8\u3002\u6309\u5e38\u89c4160W\/\u33a1\u7ea6\u97006.5kW\uff0c\u672c\u6848\u76f4\u63a5\u4e0a\u65e5\u7acb\u8212\u4eab90\u578b\uff089.0kW\uff09\uff0c\u5355\u4f4d\u51b7\u91cf\u7ea6219W\/\u33a1\uff0c\u9884\u7559\u4e86\u897f\u6652\u4e0e\u6781\u7aef\u9ad8\u6e29\u5197\u4f59\uff0c\u4fdd\u8bc1\u9ad8\u5cf0\u65f6\u6bb5\u4e5f\u80fd\u5feb\u901f\u964d\u6e29\u3001\u6e29\u5ea6\u5747\u5300\u3002<\/div><\/details>\n    <details><summary>\u7a7a\u8c03\u53ea\u5236\u51b7\uff0c\u4e3a\u4ec0\u4e48\u8fd8\u9009\u8212\u4eab\u8fd9\u79cd\u51b7\u6696\u4e24\u7528\u673a\uff1f<\/summary><div class=\"lm-faq-a\">\u672c\u6237\u51ac\u5b63\u91c7\u6696\u7531\u83f2\u65af\u66fc\u5730\u6696\u72ec\u7acb\u627f\u62c5\uff0c\u7a7a\u8c03\u5b9a\u4f4d\u4e8e\u590f\u5b63\u5236\u51b7\u4e13\u7528\uff0c\u5206\u5de5\u66f4\u6e05\u6670\uff1a\u5730\u6696\u7ba1\u91c7\u6696\u3001\u7a7a\u8c03\u7ba1\u5236\u51b7\uff0c\u4e92\u4e0d\u5e72\u6270\u3001\u5404\u53f8\u5176\u804c\u3002\u8212\u4eab\u4f5c\u4e3a\u65e5\u7acb\u54c1\u8d28\u5e73\u53f0\uff0c\u9759\u97f3\u3001\u8282\u80fd\u3001\u7a33\u5b9a\u6027\u90fd\u66f4\u4f18\uff0c\u4e14\u4fdd\u7559\u5236\u70ed\u80fd\u529b\u4f5c\u4e3a\u6781\u7aef\u5929\u6c14\u5197\u4f59\uff0c\u540e\u671f\u4f7f\u7528\u66f4\u7701\u5fc3\u3002<\/div><\/details>\n    <details><summary>\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\uff0c\u518d\u52a0\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u3001\u767d\u6676\u677f\u3001\u7eaf\u94dd\u53cd\u5c04\u819c\uff0c\u5347\u7ea7\u5728\u54ea\uff1f<\/summary><div class=\"lm-faq-a\">\u83f2\u65af\u66fcB1JG\u4e3a\u51b7\u51dd\u5f0f\u58c1\u6302\u7089\uff0c\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff1b\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u53ef\u6709\u6548\u963b\u9694\u6c27\u6c14\u6e17\u5165\u3001\u51cf\u7f13\u7cfb\u7edf\u6c27\u5316\u7ed3\u57a2\uff0c\u4fdd\u62a4\u58c1\u6302\u7089\u4e0e\u7ba1\u8def\u5bff\u547d\uff1b\u767d\u6676\u677f\u4fdd\u6e29\u6027\u80fd\u4f18\u4e8e\u666e\u901a\u6324\u5851\u677f\uff0c\u51cf\u5c11\u5411\u4e0b\u70ed\u635f\uff1b\u7eaf\u94dd\u53cd\u5c04\u819c\u53cd\u5c04\u70ed\u8f90\u5c04\u3001\u63d0\u5347\u5411\u4e0a\u5f97\u70ed\u6548\u7387\u3002\u4e09\u9879\u8f85\u6750\u5347\u7ea7\u5171\u540c\u8ba9\u5730\u6696\u66f4\u8282\u80fd\u3001\u66f4\u8010\u4e45\u3002<\/div><\/details>\n    <details><summary>\u65e5\u7acb\u548c\u7f8e\u7684\u3001\u683c\u529b\u8fd9\u4e9b\u56fd\u4ea7\u54c1\u724c\u600e\u4e48\u9009\uff1f<\/summary><div class=\"lm-faq-a\">\u4e1a\u4e3b\u5bb6\u91cc\u4eb2\u621a\u65e9\u5c31\u5728\u7528\u65e5\u7acb\uff0c\u7528\u4e0b\u6765\u5f88\u8212\u670d\uff0c\u5bf9\u65e5\u7acb\u8fd9\u4e2a\u8001\u54c1\u724c\u7684\u54c1\u8d28\u548c\u6280\u672f\u5370\u8c61\u4e00\u76f4\u6bd4\u8f83\u597d\uff1b\u672c\u6848\u4e5f\u5bf9\u6bd4\u8fc7\u7f8e\u7684\u3001\u683c\u529b\u7b49\u56fd\u4ea7\uff0c\u7efc\u5408\u54c1\u724c\u6c89\u6dc0\u3001\u538b\u7f29\u673a\u6280\u672f\u4e0e\u8212\u4eab\u8fd9\u6863\u7684\u6027\u4ef7\u6bd4\uff0c\u6700\u7ec8\u8fd8\u662f\u66f4\u8ba4\u65e5\u7acb\u3002\u9009\u62e9\u6ca1\u6709\u7edd\u5bf9\u597d\u574f\uff0c\u5173\u952e\u770b\u5bb6\u5ead\u5bf9\u9759\u97f3\u3001\u7a33\u5b9a\u3001\u552e\u540e\u7684\u4fa7\u91cd\u3002<\/div><\/details>\n    <details><summary>\u9f99\u6e56\u6e90\u8457\u8fd9\u79cd\u897f\u6652\u6237\u578b\uff0c\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u914d\u624d\u4e0d\u70ed\uff1f<\/summary><div class=\"lm-faq-a\">\u4e09\u70b9\uff1a\u4e00\u662f\u51b7\u91cf\u7559\u5197\u4f59\uff0c\u672c\u6848\u5ba2\u9910\u5385\u51b7\u91cf\u4e0a\u6d6e\u5230\u7ea6219W\/\u33a1\uff1b\u4e8c\u662f\u5185\u673a\u4f4d\u7f6e\u4e0e\u98ce\u5411\u907f\u5f00\u76f4\u5439\u3001\u8986\u76d6\u897f\u6652\u5899\u9762\uff1b\u4e09\u662f\u914d\u5408\u906e\u9633\u2014\u2014\u5348\u540e\u62c9\u7eb1\u5e18\u6216 Low-E \u73bb\u7483\u53ef\u663e\u8457\u964d\u4f4e\u51b7\u8d1f\u8377\u3002\u9f99\u8109\u4e0a\u95e8\u52d8\u6d4b\u65f6\u4f1a\u6309\u671d\u5411\u3001\u7a97\u5899\u6bd4\u5355\u72ec\u6838\u7b97\u8d1f\u8377\uff0c\u4e0d\u5957\u6a21\u677f\u3002<\/div><\/details>\n    <details><summary>\u4e09\u5ba4\u4e24\u538588\u33a1\uff0c\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5927\u6982\u600e\u4e48\u914d\u7f6e\uff1f<\/summary><div class=\"lm-faq-a\">\u672c\u6848\u53c2\u8003\u914d\u7f6e\uff1a\u7a7a\u8c03\u4e3a\u65e5\u7acb\u8212\u4eabRAS-180HRNAQ\u5355\u98ce\u6247\u4e00\u62d6\u56db\uff08\u5ba2\u9910\u538590\u578b+\u4e3b\u536740\u578b+\u4e24\u6b21\u5367\u540425\u578b\uff09\uff1b\u5730\u6696\u4e3a\u83f2\u65af\u66fcB1JG-25kW\u51b7\u51dd\u7089+\u9f99\u8109\u901a\u914d\u8f85\u6750\uff0c\u8f85\u6750\u5347\u7ea7\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u3001\u767d\u6676\u677f\u3001\u7eaf\u94dd\u53cd\u5c04\u819c\u3002\u5177\u4f53\u4ee5\u5b9e\u5730\u52d8\u6d4b\u540e\u65b9\u6848\u4e3a\u51c6\uff0c\u672c\u9875\u4e0d\u5c55\u793a\u6210\u4ea4\u4ef7\u683c\u3002<\/div><\/details>\n  <\/div>\n<\/section>\n\n<section class=\"lm-section\" id=\"links\">\n  <h2>\u4e03\u3001\u540c\u7247\u533a\u6848\u4f8b\u4e0e\u65b9\u6848\u5e93<\/h2>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11713\"><span class=\"lm-title\">\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b8c\u5de5\u6848\u4f8b\uff0c\u540c\u5c0f\u533a\u914d\u7f6e\u53c2\u8003<\/span><span class=\"lm-desc\">\u540c\u5c0f\u533a \u00b7 \u65e5\u7acb\u5168\u5c4b\u51b7\u6696\u5b8c\u5de5\u5b9e\u666f\u5bf9\u6807<\/span><\/a>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10918\"><span class=\"lm-title\">\u91d1\u725b\u533a\u5e78\u798f\u62fe\u5149\u4e8c\u671f\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u56db\u5236\u51b7\u5236\u70ed\u4e24\u7528\u5b8c\u5de5\u6848\u4f8b\uff0c\u540c\u7247\u533a\u5bf9\u6807\u53c2\u8003<\/span><span class=\"lm-desc\">\u91d1\u725b\u533a \u00b7 \u8212\u4eab\u7cfb\u5217\u540c\u6237\u578b\u51b7\u6696\u65b9\u6848\u53c2\u8003<\/span><\/a>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\"><span class=\"lm-title\">\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5ba2\u6237\u6848\u4f8b\u5e93\uff08\u6c47\u603b\uff09<\/span><span class=\"lm-desc\">\u9f99\u8109\u6696\u901a\u5168\u91cf\u5b8c\u5de5\u6848\u4f8b\u4e0e\u65b9\u6848\u53c2\u8003<\/span><\/a>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=5849\"><span class=\"lm-title\">\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4ea7\u54c1\u4e0e\u62a5\u4ef7\u8bf4\u660e<\/span><span class=\"lm-desc\">\u8212\u4eab\u7cfb\u5217\u673a\u578b\u3001\u914d\u7f6e\u4e0e\u4ef7\u683c\u6765\u6e90<\/span><\/a>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\"><span class=\"lm-title\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf\u65b9\u6848<\/span><span class=\"lm-desc\">\u58c1\u6302\u7089\u5730\u6696\u8bbe\u8ba1\u3001\u8f85\u6750\u4e0e\u65bd\u5de5<\/span><\/a>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3147\"><span class=\"lm-title\">\u897f\u6652\u6237\u578b\u4e2d\u592e\u7a7a\u8c03\u8d1f\u8377\u8bbe\u8ba1\u8981\u70b9<\/span><span class=\"lm-desc\">\u671d\u5411\u3001\u7a97\u5899\u6bd4\u4e0e\u51b7\u91cf\u5197\u4f59\u6838\u7b97<\/span><\/a>\n  <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\"><span class=\"lm-title\">\u9f99\u8109\u6696\u901a\u65bd\u5de5\u5de5\u827a\u4e0e\u516b\u5927\u9636\u6bb5\u9a8c\u6536<\/span><span class=\"lm-desc\">\u81ea\u517b\u5de5\u3001\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u3001\u4fdd\u538b\u9a8c\u6536\u6807\u51c6<\/span><\/a>\n<\/section>\n\n<section class=\"lm-cta\" id=\"cta\">\n  <h3>\u6210\u90fd\u91d1\u725b\u533a\u88c5\u7a7a\u8c03\u5730\u6696\uff1f\u9f99\u8109\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h3>\n  <p>\u65e5\u7acb\u6388\u674322\u5e74 \u00b7 \u53cc\u95e8\u5e97\u672c\u5730\u670d\u52a1 \u00b7 \u552e\u524d\u52d8\u6d4b+\u65b9\u6848+\u552e\u540e\u4e00\u4f53\u5316<\/p>\n  <p>\ud83d\udcde \u5ea7\u673a\uff1a028-61649321 \uff5c \u987e\u95ee\u5f90\u65b0\u5e73\uff1a182-2705-5065<\/p>\n  <a class=\"lm-btn\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\" rel=\"noopener noreferrer\">\u67e5\u770b\u6848\u4f8b\u5e93 \/ \u9884\u7ea6\u52d8\u6d4b<\/a>\n<\/section>\n\n<div class=\"lm-foot\">\n  \u00a9 2026 \u9f99\u8109\u6696\u901a\uff08\u6210\u90fd\uff09. \u672c\u9875\u4e3a\u5b8c\u5de5\u6848\u4f8b\u5206\u4eab\uff0c\u6587\u4e2d\u914d\u7f6e\u4e0e\u4f53\u611f\u4e3a\u540c\u6237\u578b\u5bf9\u6807\u53c2\u8003\uff0c\u5177\u4f53\u4ee5\u5b9e\u5730\u52d8\u6d4b\u540e\u65b9\u6848\u53ca\u5b8c\u5de5\u5b9e\u6d4b\u4e3a\u51c6\u3002\u6587\u4e2d\u672a\u5c55\u793a\u4e1a\u4e3b\u6210\u4ea4\u4ef7\u683c\u4e0e\u65b9\u6848\u7f16\u53f7\u3002\n<\/div>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b\", \"description\": \"\u9f99\u8109\u6696\u901a\u843d\u5730\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u4e3aG\u5973\u58eb\u81ea\u4f4f\u6539\u5584\u5b9a\u5236\u65e5\u7acb\u8212\u4eabRAS-180\u4e00\u62d6\u56db\u4e2d\u592e\u7a7a\u8c03\uff08\u53ea\u5236\u51b7\u3001\u51b7\u91cf\u505a\u5927\u5e94\u5bf9\u897f\u6652\u6015\u70ed\uff09+\u83f2\u65af\u66fcB1JG-25kW\u51b7\u51dd\u7089\u5730\u6696\uff08\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1+\u767d\u6676\u677f+\u7eaf\u94dd\u53cd\u5c04\u819c\u5347\u7ea7\uff09\uff1b\u65e5\u7acb\u6388\u674322\u5e74\uff0c\u514d\u8d39\u52d8\u6d4b\u8d1f\u8377\u6d4b\u7b97\uff0c\u6210\u90fd\u53cc\u95e8\u5e97\u552e\u540e\u65e0\u5fe7\u3002\", \"author\": {\"@type\": \"Organization\", \"name\": \"\u9f99\u8109\u6696\u901a\"}, \"publisher\": {\"@type\": \"Organization\", \"name\": \"\u9f99\u8109\u6696\u901a\", \"logo\": {\"@type\": \"ImageObject\", \"url\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\"}}, \"datePublished\": \"2026-08-28\", \"dateModified\": \"2026-08-28\", \"articleSection\": \"\u5ba2\u6237\u6848\u4f8b\", \"keywords\": \"\u65e5\u7acb\u8212\u4eab180,\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089,\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1,\u767d\u6676\u677f,\u7eaf\u94dd\u53cd\u5c04\u819c,\u91d1\u725b\u533a\u4e2d\u592e\u7a7a\u8c03,\u9f99\u6e56\u6e90\u8457\"}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"\u5ba2\u9910\u538541\u33a1\uff0c\u4e3a\u4ec0\u4e48\u752890\u578b\u5927\u51b7\u91cf\u5185\u673a\u800c\u4e0d\u662f\u66f4\u5c0f\u7684\uff1f\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u672c\u6237\u5ba2\u9910\u538541\u33a1\u4e14\u671d\u897f\u3001\u5348\u540e\u897f\u6652\u660e\u663e\uff0c\u4e00\u5bb6\u4eba\u90fd\u4e0d\u8010\u70ed\uff0c\u5bf9\u5236\u51b7\u901f\u5ea6\u548c\u4f4e\u6e29\u4f53\u9a8c\u8981\u6c42\u9ad8\u3002\u6309\u5e38\u89c4160W\/\u33a1\u7ea6\u97006.5kW\uff0c\u672c\u6848\u76f4\u63a5\u4e0a\u65e5\u7acb\u8212\u4eab90\u578b\uff089.0kW\uff09\uff0c\u5355\u4f4d\u51b7\u91cf\u7ea6219W\/\u33a1\uff0c\u9884\u7559\u4e86\u897f\u6652\u4e0e\u6781\u7aef\u9ad8\u6e29\u5197\u4f59\uff0c\u4fdd\u8bc1\u9ad8\u5cf0\u65f6\u6bb5\u4e5f\u80fd\u5feb\u901f\u964d\u6e29\u3001\u6e29\u5ea6\u5747\u5300\u3002\"}}, {\"@type\": \"Question\", \"name\": \"\u7a7a\u8c03\u53ea\u5236\u51b7\uff0c\u4e3a\u4ec0\u4e48\u8fd8\u9009\u8212\u4eab\u8fd9\u79cd\u51b7\u6696\u4e24\u7528\u673a\uff1f\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u672c\u6237\u51ac\u5b63\u91c7\u6696\u7531\u83f2\u65af\u66fc\u5730\u6696\u72ec\u7acb\u627f\u62c5\uff0c\u7a7a\u8c03\u5b9a\u4f4d\u4e8e\u590f\u5b63\u5236\u51b7\u4e13\u7528\uff0c\u5206\u5de5\u66f4\u6e05\u6670\uff1a\u5730\u6696\u7ba1\u91c7\u6696\u3001\u7a7a\u8c03\u7ba1\u5236\u51b7\uff0c\u4e92\u4e0d\u5e72\u6270\u3001\u5404\u53f8\u5176\u804c\u3002\u8212\u4eab\u4f5c\u4e3a\u65e5\u7acb\u54c1\u8d28\u5e73\u53f0\uff0c\u9759\u97f3\u3001\u8282\u80fd\u3001\u7a33\u5b9a\u6027\u90fd\u66f4\u4f18\uff0c\u4e14\u4fdd\u7559\u5236\u70ed\u80fd\u529b\u4f5c\u4e3a\u6781\u7aef\u5929\u6c14\u5197\u4f59\uff0c\u540e\u671f\u4f7f\u7528\u66f4\u7701\u5fc3\u3002\"}}, {\"@type\": \"Question\", \"name\": \"\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u7089\uff0c\u518d\u52a0\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u3001\u767d\u6676\u677f\u3001\u7eaf\u94dd\u53cd\u5c04\u819c\uff0c\u5347\u7ea7\u5728\u54ea\uff1f\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u83f2\u65af\u66fcB1JG\u4e3a\u51b7\u51dd\u5f0f\u58c1\u6302\u7089\uff0c\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff1b\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u53ef\u6709\u6548\u963b\u9694\u6c27\u6c14\u6e17\u5165\u3001\u51cf\u7f13\u7cfb\u7edf\u6c27\u5316\u7ed3\u57a2\uff0c\u4fdd\u62a4\u58c1\u6302\u7089\u4e0e\u7ba1\u8def\u5bff\u547d\uff1b\u767d\u6676\u677f\u4fdd\u6e29\u6027\u80fd\u4f18\u4e8e\u666e\u901a\u6324\u5851\u677f\uff0c\u51cf\u5c11\u5411\u4e0b\u70ed\u635f\uff1b\u7eaf\u94dd\u53cd\u5c04\u819c\u53cd\u5c04\u70ed\u8f90\u5c04\u3001\u63d0\u5347\u5411\u4e0a\u5f97\u70ed\u6548\u7387\u3002\u4e09\u9879\u8f85\u6750\u5347\u7ea7\u5171\u540c\u8ba9\u5730\u6696\u66f4\u8282\u80fd\u3001\u66f4\u8010\u4e45\u3002\"}}, {\"@type\": \"Question\", \"name\": \"\u65e5\u7acb\u548c\u7f8e\u7684\u3001\u683c\u529b\u8fd9\u4e9b\u56fd\u4ea7\u54c1\u724c\u600e\u4e48\u9009\uff1f\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u4e1a\u4e3b\u5bb6\u91cc\u4eb2\u621a\u65e9\u5c31\u5728\u7528\u65e5\u7acb\uff0c\u7528\u4e0b\u6765\u5f88\u8212\u670d\uff0c\u5bf9\u65e5\u7acb\u8fd9\u4e2a\u8001\u54c1\u724c\u7684\u54c1\u8d28\u548c\u6280\u672f\u5370\u8c61\u4e00\u76f4\u6bd4\u8f83\u597d\uff1b\u672c\u6848\u4e5f\u5bf9\u6bd4\u8fc7\u7f8e\u7684\u3001\u683c\u529b\u7b49\u56fd\u4ea7\uff0c\u7efc\u5408\u54c1\u724c\u6c89\u6dc0\u3001\u538b\u7f29\u673a\u6280\u672f\u4e0e\u8212\u4eab\u8fd9\u6863\u7684\u6027\u4ef7\u6bd4\uff0c\u6700\u7ec8\u8fd8\u662f\u66f4\u8ba4\u65e5\u7acb\u3002\u9009\u62e9\u6ca1\u6709\u7edd\u5bf9\u597d\u574f\uff0c\u5173\u952e\u770b\u5bb6\u5ead\u5bf9\u9759\u97f3\u3001\u7a33\u5b9a\u3001\u552e\u540e\u7684\u4fa7\u91cd\u3002\"}}, {\"@type\": \"Question\", \"name\": \"\u9f99\u6e56\u6e90\u8457\u8fd9\u79cd\u897f\u6652\u6237\u578b\uff0c\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u914d\u624d\u4e0d\u70ed\uff1f\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u4e09\u70b9\uff1a\u4e00\u662f\u51b7\u91cf\u7559\u5197\u4f59\uff0c\u672c\u6848\u5ba2\u9910\u5385\u51b7\u91cf\u4e0a\u6d6e\u5230\u7ea6219W\/\u33a1\uff1b\u4e8c\u662f\u5185\u673a\u4f4d\u7f6e\u4e0e\u98ce\u5411\u907f\u5f00\u76f4\u5439\u3001\u8986\u76d6\u897f\u6652\u5899\u9762\uff1b\u4e09\u662f\u914d\u5408\u906e\u9633\u2014\u2014\u5348\u540e\u62c9\u7eb1\u5e18\u6216 Low-E \u73bb\u7483\u53ef\u663e\u8457\u964d\u4f4e\u51b7\u8d1f\u8377\u3002\u9f99\u8109\u4e0a\u95e8\u52d8\u6d4b\u65f6\u4f1a\u6309\u671d\u5411\u3001\u7a97\u5899\u6bd4\u5355\u72ec\u6838\u7b97\u8d1f\u8377\uff0c\u4e0d\u5957\u6a21\u677f\u3002\"}}, {\"@type\": \"Question\", \"name\": \"\u4e09\u5ba4\u4e24\u538588\u33a1\uff0c\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5927\u6982\u600e\u4e48\u914d\u7f6e\uff1f\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u672c\u6848\u53c2\u8003\u914d\u7f6e\uff1a\u7a7a\u8c03\u4e3a\u65e5\u7acb\u8212\u4eabRAS-180HRNAQ\u5355\u98ce\u6247\u4e00\u62d6\u56db\uff08\u5ba2\u9910\u538590\u578b+\u4e3b\u536740\u578b+\u4e24\u6b21\u5367\u540425\u578b\uff09\uff1b\u5730\u6696\u4e3a\u83f2\u65af\u66fcB1JG-25kW\u51b7\u51dd\u7089+\u9f99\u8109\u901a\u914d\u8f85\u6750\uff0c\u8f85\u6750\u5347\u7ea7\u4f1f\u661f\u4e94\u5c42\u963b\u6c27\u7ba1\u3001\u767d\u6676\u677f\u3001\u7eaf\u94dd\u53cd\u5c04\u819c\u3002\u5177\u4f53\u4ee5\u5b9e\u5730\u52d8\u6d4b\u540e\u65b9\u6848\u4e3a\u51c6\uff0c\u672c\u9875\u4e0d\u5c55\u793a\u6210\u4ea4\u4ef7\u683c\u3002\"}}]}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"\u9f99\u8109\u6696\u901a\", \"item\": \"https:\/\/longmai-nt.com\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"\u5ba2\u6237\u6848\u4f8b\u5e93\", \"item\": \"https:\/\/longmai-nt.com\/?page_id=2297\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u00b7G\u5973\u58eb\uff08\u8212\u4eab180\u4e00\u62d6\u56db+\u83f2\u65af\u66fc\u5730\u6696\uff09\", \"item\": \"https:\/\/longmai-nt.com\/\"}]}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"LocalBusiness\", \"name\": \"\u9f99\u8109\u6696\u901a\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u670d\u52a1\u5546\uff09\", \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\", \"telephone\": \"028-61649321\", \"address\": {\"@type\": \"PostalAddress\", \"addressLocality\": \"\u6210\u90fd\u5e02\", \"addressRegion\": \"\u56db\u5ddd\u7701\", \"addressCountry\": \"CN\"}, \"url\": \"https:\/\/longmai-nt.com\", \"areaServed\": \"\u6210\u90fd\", \"priceRange\": \"\u00a5\u00a5\", \"openingHours\": \"09:00-18:00\"}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u203a \u5ba2\u6237\u6848\u4f8b\u5e93 \u203a \u9f99\u6e56\u6e90\u8457\u00b7 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-11797","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=11797\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a \u203a \u5ba2\u6237\u6848\u4f8b\u5e93 \u203a \u9f99\u6e56\u6e90\u8457\u00b7 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=11797\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-05T12:51:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797\",\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg\",\"datePublished\":\"2026-08-28T07:37:09+00:00\",\"dateModified\":\"2026-10-05T12:51:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11797#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=11797","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a \u203a \u5ba2\u6237\u6848\u4f8b\u5e93 \u203a \u9f99\u6e56\u6e90\u8457\u00b7 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=11797","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-05T12:51:26+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=11797","url":"https:\/\/longmai-nt.com\/?page_id=11797","name":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=11797#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=11797#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg","datePublished":"2026-08-28T07:37:09+00:00","dateModified":"2026-10-05T12:51:26+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=11797#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=11797"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=11797#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-fucaijinchangyanshou.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=11797#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11797","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11797"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11797\/revisions"}],"predecessor-version":[{"id":13983,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11797\/revisions\/13983"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11797"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}