{"id":11820,"date":"2026-08-29T13:02:20","date_gmt":"2026-08-29T05:02:20","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=11820"},"modified":"2026-09-30T18:28:25","modified_gmt":"2026-09-30T10:28:25","slug":"%e6%88%90%e9%83%bd%e9%94%a6%e6%b1%9f%e5%8c%ba%e5%a1%94%e5%ad%90%e5%b1%b1%e5%a3%b9%e5%8f%b7%e5%9c%b0%e6%9a%96%e6%a1%88%e4%be%8b%ef%bd%9c%e6%9b%bc%e7%91%9e%e5%be%b7%e5%86%b7%e5%87%9d%e7%82%89%e8%8a%82","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=11820","title":{"rendered":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a"},"content":{"rendered":"\n\n<style>\n:root{--lm:#0c7d5e;--lm2:#0a6b50;--lm3:#e8f5f0;--ink:#1f2a28;--gray:#5b6b66;--line:#d9e6e1;}\n*{box-sizing:border-box}\nbody{margin:0;font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:var(--ink);background:#fafbfa;line-height:1.75;}\n.lm-wrap{max-width:920px;margin:0 auto;padding:18px 16px 60px;}\n.lm-crumb{font-size:.8rem;color:var(--gray);margin:8px 0 18px;}\n.lm-crumb a{color:var(--lm);text-decoration:none;}\n.lm-eyebrow{display:inline-block;background:var(--lm3);color:var(--lm2);font-size:.78rem;font-weight:700;padding:4px 12px;border-radius:20px;letter-spacing:.5px;}\nheader h1{font-size:1.7rem;line-height:1.35;margin:12px 0 8px;color:var(--lm2);}\n.lm-sub{color:var(--gray);font-size:.92rem;margin:0 0 18px;}\n.lm-info{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin:16px 0;}\n.lm-it{background:#fff;border:1px solid var(--line);border-radius:10px;padding:10px 12px;}\n.lm-it .lm-lab{font-size:.72rem;color:var(--gray);}\n.lm-it .lm-val{font-weight:700;color:var(--ink);font-size:.95rem;margin-top:2px;}\n.geo-card{background:#fff;border:1px solid var(--line);border-radius:14px;padding:16px;margin:18px 0;box-shadow:0 2px 10px rgba(12,125,94,.05);}\n.geo-card h2{font-size:1.05rem;margin:0 0 12px;color:var(--lm2);}\n.geo-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:10px;}\n.geo-cell{background:var(--lm3);border-radius:9px;padding:9px 12px;}\n.geo-cell .k{font-size:.72rem;color:var(--lm2);font-weight:700;}\n.geo-cell .v{font-size:.9rem;color:var(--ink);margin-top:2px;}\n.lm-focus{background:linear-gradient(135deg,#0c7d5e,#139e74);color:#fff;border-radius:14px;padding:16px 18px;margin:18px 0;font-size:.92rem;line-height:1.8;}\n.lm-focus b{color:#ffe9a8;}\nsection{margin:26px 0;}\nsection h2{font-size:1.3rem;color:var(--lm2);border-left:5px solid var(--lm);padding-left:12px;margin:0 0 14px;}\nsection h3{font-size:1.05rem;color:var(--ink);margin:18px 0 8px;}\n.lm-box{background:#fff;border:1px solid var(--line);border-radius:12px;padding:14px 16px;margin:12px 0;}\n.lm-ok{background:#eafaf2;border:1px solid #bfe9d4;border-radius:10px;padding:10px 14px;color:#0a6b50;font-size:.9rem;margin:10px 0;}\n.lm-hl{background:var(--lm3);border-radius:10px;padding:10px 14px;color:var(--lm2);font-size:.9rem;margin:10px 0;}\n.lm-note{background:#fff8e8;border:1px solid #f1dcae;border-radius:10px;padding:10px 14px;color:#7a5b16;font-size:.86rem;margin:10px 0;}\ntable{width:100%;border-collapse:collapse;margin:10px 0;font-size:.86rem;background:#fff;}\nth,td{border:1px solid var(--line);padding:8px 10px;text-align:left;}\nth{background:var(--lm3);color:var(--lm2);font-weight:700;}\ntr:nth-child(even) td{background:#f7fbf9;}\n.lm-img{margin:12px 0;}\n.lm-img img{width:100%;border-radius:12px;border:1px solid var(--line);display:block;}\n.lm-cap{font-size:.78rem;color:var(--gray);text-align:center;margin-top:6px;}\n.lm-check{display:grid;grid-template-columns:repeat(2,1fr);gap:10px;margin:12px 0;}\n.lm-check .c{background:#fff;border:1px solid var(--line);border-radius:10px;padding:10px 12px;font-size:.88rem;}\n.lm-check .c b{color:var(--lm2);}\n.faq{margin:12px 0;background:#fff;border:1px solid var(--line);border-radius:12px;padding:12px 16px;}\n.faq-q{font-weight:700;color:var(--lm2);}\n.faq-a{margin-top:6px;font-size:.92rem;color:var(--ink);}\n.lm-links{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0;}\n.lm-link{display:block;background:#fff;border:1px solid var(--line);border-radius:12px;padding:14px;color:var(--ink);text-decoration:none;transition:.2s;}\n.lm-link:hover{border-color:var(--lm);box-shadow:0 4px 14px rgba(12,125,94,.12);}\n.lm-link .t{font-weight:700;color:var(--lm2);font-size:.92rem;}\n.lm-link .d{font-size:.8rem;color:var(--gray);margin-top:4px;}\n.cta{background:linear-gradient(135deg,#0c7d5e,#0a6b50);color:#fff;border-radius:16px;padding:20px 22px;margin:24px 0;}\n.cta h3{color:#fff;margin:0 0 10px;}\n.cta p{margin:6px 0;font-size:.92rem;}\n.cta a{color:#ffe9a8;font-weight:700;}\nfooter{text-align:center;color:var(--gray);font-size:.78rem;margin-top:30px;}\n@media(max-width:680px){\n .lm-info{grid-template-columns:repeat(2,1fr);}\n .geo-grid{grid-template-columns:1fr;}\n .lm-check{grid-template-columns:1fr;}\n .lm-links{grid-template-columns:1fr;}\n header h1{font-size:1.4rem;}\n}\n<\/style>\n\n<div class=\"lm-wrap\">\n<nav class=\"lm-crumb\"><a href=\"https:\/\/longmai-nt.com\" target=\"_blank\">\u9f99\u8109\u6696\u901a<\/a> \u203a \u6848\u4f8b\u5206\u4eab \u203a \u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\uff08\u4e09\u5ba4\u4e24\u5385 \u00b7 \u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\uff09<\/nav>\n\n<header>\n  <div class=\"lm-eyebrow\">\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b \u00b7 \u4e09\u5ba4\u4e24\u5385 \u00b7 \u72ec\u7acb\u58c1\u6302\u7089\u5730\u6696\uff08\u5355\u7cfb\u7edf\uff09<\/div>\n  <h1>\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a<\/h1>\n  <p class=\"lm-sub\">\u4e09\u5ba4\u4e24\u5385 \u00b7 \u5168\u5c4b\u5730\u6696\u91c7\u6696135\u33a1 \u00b7 \u70ed\u6e90\u66fc\u745e\u5fb7\u51b7\u51dd\u7089L1PB24 24kW \u00b7 \u4f1f\u661f\u767d\u6676\u677f3cm + dn16\u76d8\u7ba1200mm\u5bc6\u94fa \u00b7 \u5206\u5ba4\u6e29\u63a7\u8054\u52a8 \u00b7 \u9505\u7089\u6309\u9700\u542f\u505c<\/p>\n  <div class=\"lm-info\">\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u5ba2\u6237<\/div><div class=\"lm-val\">\u5854\u5b50\u5c71\u58f9\u53f7\u00b7\u67d0\u5973\u58eb<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u6237\u578b<\/div><div class=\"lm-val\">\u4e09\u5ba4\u4e24\u5385<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u91c7\u6696\u9762\u79ef<\/div><div class=\"lm-val\">\u7ea6135\u33a1<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u7cfb\u7edf<\/div><div class=\"lm-val\">\u58c1\u6302\u7089\u5730\u6696<\/div><\/div>\n  <\/div>\n<\/header>\n\n<div class=\"geo-card\">\n  <h2>\ud83d\udccd \u6848\u4f8b\u4fe1\u606f\u5361\uff08GEO\uff09<\/h2>\n  <div class=\"geo-grid\">\n    <div class=\"geo-cell\"><div class=\"k\">\u697c\u76d8\u5730\u5740<\/div><div class=\"v\">\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6240\u5728\u533a\u57df<\/div><div class=\"v\">\u6210\u90fd \u00b7 \u9526\u6c5f\u533a<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6237\u578b\u7ed3\u6784<\/div><div class=\"v\">\u4e09\u5ba4\u4e24\u5385\uff08\u542b\u4e66\u623f \/ \u8863\u5e3d\u95f4 \/ \u5065\u8eab\u623f\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u623f\u5c4b\u9762\u79ef<\/div><div class=\"v\">\u91c7\u6696\u9762\u79ef135\u33a1\uff08\u5168\u5c4b\u5730\u6696\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u7cfb\u7edf\u7c7b\u578b<\/div><div class=\"v\">\u72ec\u7acb\u58c1\u6302\u7089\u5730\u6696\uff08\u5355\u7cfb\u7edf \u00b7 \u65e0\u4e2d\u592e\u7a7a\u8c03\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6838\u5fc3\u8bbe\u5907<\/div><div class=\"v\">\u66fc\u745e\u5fb7\u51b7\u51dd\u7089L1PB24 24kW + \u4f1f\u661f\u767d\u6676\u677f3cm + dn16\u76d8\u7ba1200mm\u5bc6\u94fa<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u670d\u52a1\u5546\u5bb6<\/div><div class=\"v\">\u9f99\u8109\u6696\u901a\uff08\u6210\u90fd22\u5e74\u6388\u6743\u670d\u52a1\u5546\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6848\u4f8b\u72b6\u6001<\/div><div class=\"v\">\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b \/ \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/div><\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lm-focus\">\n  \ud83c\udfaf <b>\u7126\u70b9\u5173\u952e\u8bcd<\/b>\uff1a\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u91c7\u6696\u516c\u5bd3\uff0c\u4e1a\u4e3b\u5bf9\u5168\u5c4b\u8212\u9002\u91c7\u6696\uff08\u51ac\u5b63\u5ba4\u6e2918-22\u2103\uff09\u3001\u8fd0\u884c\u8d39\u7528\u53ef\u63a7\u3001\u5206\u5ba4\u72ec\u7acb\u63a7\u6e29\u3001\u9690\u853d\u5de5\u7a0b\u53ef\u9760\u53ca\u9505\u7089\u8fd0\u884c\u566a\u97f3\u654f\u611f\u6709\u660e\u786e\u8bc9\u6c42\uff0c\u6700\u7ec8\u5728\u56db\u79cd\u65b9\u6848\u5bf9\u6bd4\u540e\u9009\u5b9a\u65b9\u6848\u4e09\u00b7\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u5957\u9910\uff08L1PB24-Heidelberg 24kW\u51b7\u51dd\u7089 + \u4f1f\u661f\u767d\u6676\u677f3cm + dn16 PE-RT\u76d8\u7ba1200mm\u5bc6\u94fa + \u66fc\u745e\u5fb7\u5206\u96c6\u6c34\u5668\u5e26\u6d41\u91cf\u8ba1\u4e0e\u7535\u70ed\u6267\u884c\u5668 + \u5206\u5ba4\u6e29\u63a7\u8054\u52a8\uff09\u3002\u672c\u6848\u4f8b\u7531\u9f99\u8109\u6696\u901a\uff08\u6210\u90fd22\u5e74\u6388\u6743\u670d\u52a1\u5546\uff09\u8bbe\u8ba1\u65bd\u5de5\uff0c\u4e25\u683c\u6309GB50736\u4e0eJGJ142\u53cc\u56fd\u6807\u9a8c\u6536\uff0c\u5206\u5ba4\u6e29\u63a7\u8054\u52a8\u8ba9\u9505\u7089\u6309\u9700\u542f\u505c\u3001\u6d88\u9664\u65e0\u6548\u4ea7\u70ed\uff0c\u9002\u5408\u6210\u90fd\u6e7f\u51b7\u6c14\u5019\u4e0b\u6ce8\u91cd\u8282\u80fd\u4e0e\u9759\u97f3\u7684\u4e09\u5ba4\u53ca\u4ee5\u4e0a\u5bb6\u5ead\u53c2\u8003\u3002\n<\/div>\n\n<!-- S1 -->\n<section>\n  <h2>S1 \u00b7 \u5ba2\u6237\u9700\u6c42\u4e0e\u6237\u578b\u8bca\u65ad<\/h2>\n  <h3>1.1 \u91c7\u6696\u5206\u533a\u4e0e\u5404\u533a\u57df\u660e\u7ec6<\/h3>\n  <div class=\"lm-box\">\n    <table>\n      <tbody><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u8bbe\u8ba1\u8d1f\u8377(160W\/\u33a1)<\/th><th>\u5236\u70ed\u91cf(W)<\/th><th>\u529f\u80fd\u5b9a\u4f4d<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385<\/td><td>67.3<\/td><td>10.8kW<\/td><td>10,768<\/td><td>\u4f1a\u5ba2 \/ \u7528\u9910\u6838\u5fc3\u533a<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>33.5<\/td><td>5.4kW<\/td><td>5,360<\/td><td>\u4e3b\u4eba\u4f11\u606f<\/td><\/tr>\n      <tr><td>\u4e66\u623f<\/td><td>9.5<\/td><td>1.5kW<\/td><td>1,520<\/td><td>\u529e\u516c \/ \u9605\u8bfb<\/td><\/tr>\n      <tr><td>\u8863\u5e3d\u95f4<\/td><td>12.7<\/td><td>2.0kW<\/td><td>2,032<\/td><td>\u50a8\u7269 \/ \u66f4\u8863<\/td><\/tr>\n      <tr><td>\u5065\u8eab\u623f<\/td><td>9.5<\/td><td>1.5kW<\/td><td>1,520<\/td><td>\u8fd0\u52a8 \/ \u4f11\u95f2<\/td><\/tr>\n      <tr style=\"background:#f0f0f0;font-weight:700\"><td>\u5408\u8ba1<\/td><td>132.5<\/td><td>21.2kW<\/td><td>21,200<\/td><td>\u5168\u5c4b\u5730\u6696 \u00b7 \u91c7\u6696\u7ea6135\u33a1<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"lm-note\">\ud83d\udcdd \u8868\u4e2d\u5206\u9879\u5408\u8ba1132.5\u33a1\uff0c\u5bf9\u5916\u6309\u8bbe\u8ba1\u91c7\u6696\u9762\u79ef135\u33a1\u8ba1\uff1b\u8d1f\u8377\u6309\u6210\u90fd\u51ac\u5b63\u6807\u51c6160W\/\u33a1\u53d6\u503c\uff0c\u8be6\u89c12.4\u53cc\u56fd\u6807\u3002<\/div>\n  <\/div>\n  <h3>1.2 \u529f\u7387\u9700\u6c42\u4e0e\u9505\u7089\u5339\u914d<\/h3>\n  <div class=\"lm-box\">\n    <p>\u5168\u5c4b\u91c7\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377\u7ea6 135\u33a1 \u00d7 160W\/\u33a1 \u2248 <b>21.6kW<\/b>\u3002\u672c\u6848\u4f8b\u9009\u7528 <b>24kW \u51b7\u51dd\u7089<\/b>\uff0c\u5904\u4e8e135\u33a1\u6237\u578b\u7684\"\u9ec4\u91d1\u5339\u914d\u533a\u95f4\"\u2014\u2014\u65e2\u80fd\u6ee1\u8d1f\u8377\u8986\u76d6\u6700\u51b7\u65e5\uff0c\u53c8\u56e0\u51b7\u51dd\u7089\u8c03\u8282\u6bd4\u5bbd\u3001\u4f4e\u9891\u8fd0\u884c\u5e73\u7a33\uff0c\u65e5\u5e38\u90e8\u5206\u8d1f\u8377\u66f4\u7701\u6c14\u3002<\/p>\n    <div class=\"lm-ok\">\u2713 24~25kW \u51b7\u51dd\u7089\u5bf9135\u33a1\u5168\u5c4b\u5730\u6696\u5b8c\u5168\u80dc\u4efb\uff1b\u66fc\u745e\u5fb7L1PB24\u8c03\u8282\u6bd4\u8fbe1:8\uff0c\u4f4e\u9891\u8f93\u51fa\u7a33\u5b9a\uff0c\u5951\u5408\u4e24\u4e09\u4eba\u4f4e\u9891\u4f7f\u7528\u573a\u666f\u3002<\/div>\n  <\/div>\n  <h3>1.3 \u6838\u5fc3\u8bc9\u6c42\u4e0e\u75db\u70b9<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4e1a\u4e3b\u5bf9\u8fd9\u5957\u4e09\u5ba4\u4e24\u5385\u7684\u6838\u5fc3\u8bc9\u6c42\u5f88\u660e\u786e\uff1a<b>\u5168\u5c4b\u8212\u9002\u91c7\u6696\uff08\u51ac\u5b63\u5ba4\u6e2918-22\u2103\uff09\u3001\u8fd0\u884c\u8d39\u7528\u53ef\u63a7\u3001\u5404\u623f\u95f4\u72ec\u7acb\u63a7\u6e29\u3001\u9690\u853d\u5de5\u7a0b\u53ef\u9760\u3001\u9505\u7089\u8fd0\u884c\u4e0e\u7ba1\u8def\u566a\u97f3\u654f\u611f<\/b>\u3002\u75db\u70b9\u96c6\u4e2d\u5728\u56db\u70b9\uff1a<\/p>\n    <p>\u2460 \u6210\u90fd\u51ac\u5b63\u6e7f\u51b7\uff0c\u666e\u901a\u53d6\u6696\u4f53\u611f\u5dee\uff0c\u9700\u8981\u5168\u5c4b\u5747\u5300\u8f90\u5c04\u4f9b\u6696\uff1b<br>\n    \u2461 \u62c5\u5fc3\u8fd0\u884c\u8d39\u7528\u9ad8\u3001\u80fd\u8017\u4e0d\u53ef\u63a7\uff1b<br>\n    \u2462 \u4e0d\u540c\u623f\u95f4\u4f7f\u7528\u65f6\u95f4\u4e0d\u540c\uff0c\u9700\u8981\u5206\u5ba4\u72ec\u7acb\u63a7\u6e29\u3001\u4e92\u4e0d\u5f71\u54cd\uff1b<br>\n    \u2463 \u9505\u7089\u4e0e\u7ba1\u8def\u566a\u97f3\u654f\u611f\uff0c\u8981\u6c42\u8bbe\u5907\u8fd0\u884c\u5b89\u9759\u3001\u53d8\u9891\u964d\u566a\u3002<\/p>\n    <div class=\"lm-hl\">\ud83d\udca1 <b>\u672c\u5730\u6c14\u5019\u6ce8\u89e3<\/b>\uff1a\u9526\u6c5f\u533a\u5c5e\u6210\u90fd\u5178\u578b\u6e7f\u51b7\u6c14\u5019\uff0c\u51ac\u5b63\u9634\u51b7\u671f\u957f\u3002\u672c\u5957\u65b9\u6848\u8d1f\u8377\u53d6\u503c\u5145\u5206\u8003\u8651\u533a\u57df\u56f4\u62a4\u7ed3\u6784\u7279\u70b9\uff0c\u8bbe\u8ba1\u6c34\u6e2935~45\u2103\u3001\u5ba4\u6e2918~22\u2103\uff0c\u517c\u987e\u8212\u9002\u4e0e\u80fd\u8017\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S2 -->\n<section>\n  <h2>S2 \u00b7 \u8bbe\u8ba1\u65b9\u6848\u4e0e\u8bbe\u5907\u914d\u7f6e<\/h2>\n  <h3>2.1 \u7cfb\u7edf\u539f\u7406\uff1a\u72ec\u7acb\u58c1\u6302\u7089\u5730\u6696\uff08\u5355\u7cfb\u7edf\uff09<\/h3>\n  <div class=\"lm-box\">\n    <p><b>\u58c1\u6302\u7089\u5730\u6696<\/b>\uff1a\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u71c3\u70e7\u4ea7\u70ed\u6c34\uff0c\u9001\u5165\u5730\u6696\u76d8\u7ba1\u8f90\u5c04\u4f9b\u70ed\uff0c\u4ee5\"\u6e29\u8db3\u51c9\u9876\"\u7684\u65b9\u5f0f\u5747\u5300\u6e29\u6696\u5168\u5c4b\u3002\u672c\u6848\u4f8b\u4e3a<b>\u5355\u7cfb\u7edf\u5730\u6696<\/b>\uff08\u4e0d\u542b\u4e2d\u592e\u7a7a\u8c03\uff09\uff0c\u70ed\u6e90\u4e0e\u672b\u7aef\u7531\u4e00\u5957\u51b7\u51dd\u7089\u7cfb\u7edf\u7edf\u7b79\u3002<\/p>\n    <div class=\"lm-ok\">\u2713 \u5206\u5ba4\u6e29\u63a7 + \u9505\u7089\u8054\u52a8\uff0c\u8ba9\u9505\u7089\u6309\u9700\u542f\u505c\u3001\u6d88\u9664\u65e0\u6548\u4ea7\u70ed\uff1b\u5404\u623f\u95f4\u72ec\u7acb\u8bbe\u5b9a\u6e29\u5ea6\uff0c\u65e0\u4eba\u623f\u95f4\u53ef\u5355\u72ec\u4f4e\u6e29\u8fd0\u884c\uff0c\u517c\u987e\u8212\u9002\u4e0e\u8282\u80fd\u3002<\/div>\n  <\/div>\n  <h3>2.2 \u65b9\u6848\u4e09 \u00b7 \u66fc\u745e\u5fb7\u51b7\u51dd\u7089 + \u8282\u80fd\u5957\u9910 \u8bbe\u5907\u914d\u7f6e<\/h3>\n  <div class=\"lm-box\">\n    <table>\n      <tbody><tr><th>\u9879\u76ee<\/th><th>\u914d\u7f6e<\/th><th>\u8bf4\u660e<\/th><\/tr>\n      <tr><td>\u70ed\u6e90\uff08\u9505\u7089\uff09<\/td><td>\u66fc\u745e\u5fb7\u51b7\u51dd\u7089 L1PB24-Heidelberg<\/td><td>24kW \u00b7 \u70ed\u6548\u7387108% \u00b7 \u6cd5\u56fd\u8d5b\u8fc8\u8fbe441\u4e0d\u9508\u94a2\u6362\u70ed\u5668 \u00b7 \u8c03\u8282\u6bd41:8 \u00b7 \u516b\u5e74\u4fdd\u4fee<\/td><\/tr>\n      <tr><td>\u667a\u80fd\u63a7\u5236<\/td><td>\u5206\u5ba4\u6e29\u63a7 + \u9505\u7089\u8054\u52a8<\/td><td>\u9505\u7089\u6309\u9700\u542f\u505c\uff0c\u6d88\u9664\u65e0\u6548\u4ea7\u70ed<\/td><\/tr>\n      <tr><td>\u4e3b\u7ba1<\/td><td>De32 PPR<\/td><td>\u4f18\u4e8e\u901a\u914dDe25\uff0c\u6c34\u6d41\u91cf\u66f4\u8db3\u3001\u8fdc\u7aef\u66f4\u5747\u6e29<\/td><\/tr>\n      <tr><td>\u76d8\u7ba1<\/td><td>dn16 PE-RT<\/td><td>200mm\u5bc6\u94fa\uff0c\u6563\u70ed\u66f4\u5747\u5300<\/td><\/tr>\n      <tr><td>\u4fdd\u6e29\u677f<\/td><td>\u4f1f\u661f\u767d\u6676\u677f 3cm<\/td><td>\u4f18\u4e8e\u901a\u914d\u6324\u5851\u677f2cm\uff0c\u5411\u4e0b\u70ed\u635f\u66f4\u4f4e<\/td><\/tr>\n      <tr><td>\u53cd\u5c04\u819c<\/td><td>\u955c\u9762\u94dd\u7b94\u53cd\u5c04\u819c<\/td><td>\u51cf\u5c11\u5411\u4e0b\u8f90\u5c04\u70ed\u635f<\/td><\/tr>\n      <tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u66fc\u745e\u5fb7 + \u6d41\u91cf\u8ba1 + \u7535\u70ed\u6267\u884c\u5668<\/td><td>\u6bcf\u56de\u8def\u6d41\u91cf\u53ef\u89c6\u3001\u7535\u52a8\u7cbe\u51c6\u63a7\u5236<\/td><\/tr>\n      <tr><td>\u6e29\u63a7\u5668<\/td><td>\u5206\u5ba4\u6e29\u63a7 + \u8054\u52a8<\/td><td>\u5404\u623f\u95f4\u72ec\u7acb\u8bbe\u5b9a\uff0c\u8054\u52a8\u9505\u7089<\/td><\/tr>\n      <tr><td>\u94a2\u4e1d\u7f51 \/ \u8fb9\u754c\u6761<\/td><td>\u52a0\u5bc6\u94a2\u4e1d\u7f51 + EPE\u4f38\u7f29\u7f1d<\/td><td>\u9632\u5f00\u88c2\u3001\u91ca\u653e\u70ed\u80c0<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"lm-hl\">\ud83c\udfaf \u672c\u6848\u4f8b\u76f8\u5bf9\u901a\u914d\u65b9\u6848\uff08\u6324\u5851\u677f2cm \/ De25\u4e3b\u7ba1 \/ \u65e0\u8054\u52a8\uff09\u7684\u6838\u5fc3\u5347\u7ea7\uff1a<b>\u4f1f\u661f\u767d\u6676\u677f3cm + De32\u4e3b\u7ba1 + \u9505\u7089\u8054\u52a8<\/b>\u2014\u2014\u4e09\u8005\u53e0\u52a0\u662f\"\u91c7\u6696\u8d39\u7701\u7ea630%\"\u7684\u786c\u4ef6\u57fa\u7840\uff0c\u5177\u4f53\u8282\u80fd\u5e45\u5ea6\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ee5\u4e0b\u6570\u636e\u4e3a\u540c\u6237\u578b\u6a21\u578b\u6d4b\u7b97\uff0c\u4e0d\u4f5c\u6bcf\u6237\u627f\u8bfa\u3002<\/div>\n  <\/div>\n  <h3>2.3 \u4ef7\u683c\u4f53\u7cfb\uff08\u53c2\u8003\uff0c\u975e\u6237\u6210\u4ea4\uff09<\/h3>\n  <div class=\"lm-box\">\n    <p>\u5730\u6696\u6309\u9f99\u8109\u6696\u901a\u4ef7\u683c\u4f53\u7cfb\u6838\u7b97\uff0c\u672c\u6848\u4f8b\u9009\u7528<b>\u8282\u80fd\u5957\u9910\uff08\u7ea6169\u5143\/\u33a1\u6807\u51c6\uff0c\u91c7\u6696\u7ea6135\u33a1\uff09<\/b>\uff1b\u70ed\u6e90\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u4e3a\u56fd\u8865\u540e\u5e02\u573a\u4ef7\uff08\u7ea67,800\u5143 + \u5b89\u88c5600\u5143\uff09\u3002<b>\u5177\u4f53\u65b9\u6848\u62a5\u4ef7\u4ee5\u73b0\u573a\u52d8\u6d4b\u540e\u4e3a\u51c6<\/b>\u3002<\/p>\n    <div class=\"lm-note\">\ud83d\udcdd \u6848\u4f8b\u5206\u4eab\u4e0d\u62ab\u9732\u6237\u6210\u4ea4\u91d1\u989d\uff1b\u4e0a\u8868\u4e3a\u9f99\u8109\u6696\u901a\u516c\u5f00\u4ef7\u683c\u4f53\u7cfb\u4e0e\u8bbe\u5907\u6807\u51c6\uff0c\u4f9b\u540c\u6237\u578b\u53c2\u8003\u3002<\/div>\n  <\/div>\n  <h3>2.4 \u6267\u884c\u6807\u51c6 \u00b7 \u53cc\u56fd\u6807\u5f15\u7528<\/h3>\n  <div class=\"lm-box\">\n    <p>\u672c\u65b9\u6848\u8d1f\u8377\u8ba1\u7b97\u4e0e\u7cfb\u7edf\u8bbe\u8ba1\u4e25\u683c\u53c2\u7167\u56fd\u5bb6\u73b0\u884c\u6807\u51c6\uff1a<\/p>\n    <p>\u00b7 <b>GB 50736\u20112012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/b>\u2014\u2014\u4f9b\u6696\u8d1f\u8377\u3001\u7cfb\u7edf\u8bbe\u8ba1\u4f9d\u636e\uff1b<br>\n    \u00b7 <b>JGJ 142\u20112012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/b>\u2014\u2014\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\u3001\u5206\u96c6\u6c34\u5668\u4e0e\u56de\u586b\u5de5\u827a\u4f9d\u636e\u3002<\/p>\n    <div class=\"lm-note\">\ud83d\udcdd \u5730\u6696\u5c5e\u53d7\u76d1\u5de5\u7a0b\uff0c\u5b89\u88c5\u5de5\u827a\u4e0e\u9a8c\u6536\u987b\u843d\u5230\u73b0\u573a\u6bcf\u4e00\u6b65\uff0c\u8be6\u89c12.5\u3002<\/div>\n  <\/div>\n  <h3>2.5 \u65bd\u5de5\u9a8c\u6536\u8981\u70b9\uff084\u9879\uff09<\/h3>\n  <div class=\"lm-check\">\n    <div class=\"c\"><b>\u2460 \u76d8\u7ba1\u4fdd\u538b<\/b>\uff1a\u6c34\u538b0.6\u20130.8MPa\uff0c\u7a33\u538b\u22651\u5c0f\u65f6\uff0c\u538b\u964d\u22640.05MPa\uff0c\u65e0\u6e17\u6f0f\u3002<\/div>\n    <div class=\"c\"><b>\u2461 \u5206\u96c6\u6c34\u5668<\/b>\uff1a\u5b9a\u4f4d\u6c34\u5e73\u3001\u5404\u56de\u8def\u6d41\u91cf\u8ba1\u4e0e\u7535\u70ed\u6267\u884c\u5668\u63a5\u7ebf\u6821\u51c6\u3002<\/div>\n    <div class=\"c\"><b>\u2462 \u8054\u52a8\u8c03\u8bd5<\/b>\uff1a\u5206\u5ba4\u6e29\u63a7\u4e0e\u9505\u7089\u8054\u52a8\u542f\u505c\u6d4b\u8bd5\uff0c\u6d88\u9664\u65e0\u6548\u4ea7\u70ed\u3002<\/div>\n    <div class=\"c\"><b>\u2463 \u56de\u586b\u627e\u5e73<\/b>\uff1aC20\u7ec6\u77f3\u6df7\u51dd\u571f\u56de\u586b\uff08\u542b\u4fdd\u6e29\u677f3cm\uff0c\u539a\u7ea650\u201360mm\uff09\uff0c\u517b\u62a4\u540e\u65e0\u7a7a\u9f13\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S3 -->\n<section>\n  <h2>S3 \u00b7 \u65bd\u5de5\u5de5\u827a\u6807\u51c6<\/h2>\n  <h3>3.1 \u9f99\u8109\u7cbe\u5de5\u5de5\u827a\u8981\u70b9<\/h3>\n  <div class=\"lm-box\">\n    <p>\u672c\u6848\u4f8b\u6cbf\u7528\u9f99\u8109\u6696\u901a\u7edf\u4e00\u7cbe\u5de5\u5de5\u827a\uff1a\u8f85\u6750\u8fdb\u573a\u9a8c\u6536 \u2192 \u4fdd\u6e29\u677f\u4e0e\u8fb9\u754c\u6761\u94fa\u8bbe \u2192 \u76d8\u7ba1\u6309200mm\u5bc6\u94fa\uff08\u65e0\u63a5\u5934\u660e\u8bbe\uff09\u2192 \u5206\u96c6\u6c34\u5668\u5b9a\u4f4d\u4e0e\u8fde\u63a5 \u2192 \u5206\u5ba4\u6e29\u63a7\u4e0e\u8054\u52a8\u5e03\u7ebf \u2192 \u4fdd\u538b\u9a8c\u6536 \u2192 \u56de\u586b\u627e\u5e73\u3002\u6bcf\u4e00\u6b65\u5747\u6309\u53cc\u56fd\u6807\u4e0e\u5382\u5bb6\u5de5\u827a\u624b\u518c\u6267\u884c\uff0c\u5173\u952e\u8282\u70b9\u7559\u75d5\u5f52\u6863\u3002<\/p>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\u5b9e\u666f\uff0c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-gdaz.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u4e3b\u7ba1\u4e0e\u76d8\u7ba1\u5b89\u88c5\u5b9e\u666f\uff0c\u5730\u6696\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-pyk.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u76d8\u7ba1\u76d8\u7ed5\u94fa\u8bbe\u5b9e\u666f\uff0c\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n  <\/div>\n<\/section>\n\n<!-- S4 -->\n<section>\n  <h2>S4 \u00b7 \u65bd\u5de5\u5b9e\u666f\u56fe\u96c6<\/h2>\n  <h3>4.1 \u5173\u952e\u8282\u70b9\u5b9e\u666f<\/h3>\n  <div class=\"lm-box\">\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u4e0e\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5b9e\u666f\uff0c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-dnpg-01.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u76d8\u7ba1\u5bc6\u94fa\u5b9e\u666f\uff0c\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-ydaz.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u58c1\u6302\u7089\u4e0e\u672b\u7aef\u8bbe\u5907\u5b89\u88c5\u5b9e\u666f\uff0c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-dnxkqaz.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5206\u96c6\u6c34\u5668\u4e0e\u6e29\u63a7\u5668\u5b89\u88c5\u5b9e\u666f\uff0c\u5206\u5ba4\u6e29\u63a7\u8054\u52a8\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-cxglf.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u7ba1\u8def\u8fde\u63a5\u4e0e\u7cfb\u7edf\u8c03\u8bd5\u5b9e\u666f\uff0c\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n    <div class=\"lm-note\">\ud83d\udcdd \u56fe\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6807\u51c6\u7cbe\u5de5\u5de5\u827a\u793a\u610f\uff1b\u672c\u6848\u5b8c\u5de5\u5b9e\u62cd\u56fe\u7531\u4e1a\u4e3b\u6388\u6743\u540e\u5f52\u6863\u66ff\u6362\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S5 -->\n<section>\n  <h2>S5 \u00b7 \u6548\u679c\u5bf9\u6bd4\u4e0e\u5ba2\u6237\u53cd\u9988<\/h2>\n  <h3>5.1 \u8282\u80fd\u6548\u679c\u5bf9\u6807\uff08\u540c\u6237\u578b\u6a21\u578b\u6d4b\u7b97\uff09<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6237\u578b\uff08135\u33a1\u5168\u5c4b\u5730\u6696\uff09\u901a\u914d\u65b9\u6848\u4e0e\u8282\u80fd\u5957\u9910\u7684<b>\u6a21\u578b\u6d4b\u7b97\u5bf9\u6807<\/b>\uff0c<b>\u672c\u6237\u5b9e\u9645\u6548\u679c\u4ee5\u5b8c\u5de5\u8c03\u8bd5\u540e\u7684\u73b0\u573a\u5b9e\u6d4b\u4e3a\u51c6<\/b>\u3002<\/p>\n    <table>\n      <tbody><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u901a\u914d\u65b9\u6848\uff08\u6324\u5851\u677f2cm \/ \u65e0\u8054\u52a8\uff09<\/th><th>\u672c\u6848\u4f8b\u8282\u80fd\u5957\u9910\uff08\u767d\u6676\u677f3cm \/ \u8054\u52a8\uff09<\/th><\/tr>\n      <tr><td>\u6708\u5747\u71c3\u6c14\u8d39<\/td><td>\u7ea6900\u20131,000\u5143<\/td><td>\u7ea6620\u2013700\u5143<\/td><\/tr>\n      <tr><td>\u5e74\u8fd0\u884c\u8d39\uff083.5\u6708\u91c7\u6696\u5b63\uff09<\/td><td>\u7ea63,100\u20133,500\u5143<\/td><td>\u7ea62,100\u20132,400\u5143<\/td><\/tr>\n      <tr><td>\u76f8\u5bf9\u901a\u914d\u8282\u7701<\/td><td>\u57fa\u51c6<\/td><td>\u6709\u673a\u4f1a\u964d\u4f4e\u7ea630%<\/td><\/tr>\n      <tr><td>\u5e74\u8282\u7701\u91d1\u989d<\/td><td>\u2014<\/td><td>\u7ea6900\u20131,200\u5143\/\u5e74<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"lm-note\">\u26a0\ufe0f \u8282\u80fd\u5e45\u5ea6\u4e3a\u540c\u6237\u578b\u6a21\u578b\u6d4b\u7b97\uff08\u6210\u90fd\u91c7\u6696\u5b633.5\u4e2a\u6708\u3001\u6c14\u4ef72.0\u5143\/m\u00b3\uff09\uff0c<b>\u5b9e\u9645\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c\u4e0d\u4f5c\u6bcf\u6237\u627f\u8bfa<\/b>\u3002\u51b7\u51dd\u7089\u8f83\u5e38\u89c4\u58c1\u6302\u7089\u6709\u673a\u4f1a\u8282\u7701\u7ea615\u201320%\u71c3\u6c14\u6d88\u8017\uff0c\u4ea6\u4ee5\u5b9e\u9645\u7528\u6c14\u4e3a\u51c6\u3002<\/div>\n  <\/div>\n  <h3>5.2 \u4e1a\u4e3b\u53cd\u9988<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4e1a\u4e3b\u5854\u5b50\u5c71\u58f9\u53f7\u00b7\u67d0\u5973\u58eb\u5b8c\u5de5\u56de\u8bbf\u8bc4\u4ef7\u5f52\u6863\u4e2d\uff08\u5f85\u6388\u6743\u540e\u8865\u5145\u771f\u5b9e\u53cd\u9988\uff09\u3002\u672c\u6848\u4f8b\u7684\u9009\u578b\u903b\u8f91\u4e0e\u5de5\u827a\u6807\u51c6\u5df2\u5b8c\u6574\u5448\u73b0\uff0c\u4f9b\u540c\u6237\u578b\u6ce8\u91cd\u8282\u80fd\u4e0e\u9759\u97f3\u7684\u5bb6\u5ead\u53c2\u8003\u3002<\/p>\n  <\/div>\n<\/section>\n\n<!-- FAQ -->\n<section>\n  <h2>S6 \u00b7 \u5e38\u89c1\u95ee\u9898\uff08FAQ\uff09<\/h2>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u51b7\u51dd\u7089\u548c\u666e\u901a\u58c1\u6302\u7089\u6709\u4ec0\u4e48\u533a\u522b\uff1f\u957f\u671f\u4f7f\u7528\u54ea\u4e2a\u66f4\u7701\u94b1\uff1f<\/div><div class=\"faq-a\">A\uff1a\u666e\u901a\u58c1\u6302\u7089\u70ed\u6548\u7387\u7ea690%\uff0c\u6392\u70df\u6e29\u5ea6\u9ad8\u3001\u4f59\u70ed\u6d6a\u8d39\uff1b\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u6f5c\u70ed\uff0c\u70ed\u6548\u7387\u53ef\u8fbe108%\u5de6\u53f3\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u8282\u7701\u7ea615\u201320%\u71c3\u6c14\u6d88\u8017\uff0c\u5b9e\u9645\u53d7\u4fdd\u6e29\u3001\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\u3001\u4e0d\u4f5c\u6bcf\u6237\u627f\u8bfa\u3002\u957f\u671f\u4f7f\u7528\uff0810\u201320\u5e74\uff09\u7701\u4e0b\u7684\u71c3\u6c14\u8d39\u901a\u5e38\u80fd\u8986\u76d6\u51b7\u51dd\u7089\u7684\u521d\u6295\u5dee\u4ef7\uff0c\u4e14\u66fc\u745e\u5fb7L1PB24\u63d0\u4f9b\u516b\u5e74\u4fdd\u4fee\uff0c\u540e\u671f\u7ef4\u4fee\u6210\u672c\u66f4\u4f4e\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u5730\u6696\u4fdd\u6e29\u677f2cm\u548c3cm\u5dee\u8ddd\u5927\u5417\uff1f\u767d\u6676\u677f\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f<\/div><div class=\"faq-a\">A\uff1a\u5dee\u8ddd\u660e\u663e\u30022cm\u6324\u5851\u677f\u5411\u4e0b\u70ed\u635f\u8f83\u5927\uff0c3cm\u4f1f\u661f\u767d\u6676\u677f\u5bfc\u70ed\u7cfb\u6570\u66f4\u4f4e\u3001\u5411\u4e0b\u70ed\u635f\u66f4\u5c0f\uff0c\u66f4\u591a\u70ed\u91cf\u5411\u4e0a\u8fdb\u5165\u623f\u95f4\u3002\u5bf9135\u33a1\u5168\u5c4b\u5730\u6696\uff0c\u767d\u6676\u677f3cm\u914d\u5408\u955c\u9762\u94dd\u7b94\u53cd\u5c04\u819c\uff0c\u662f\"\u91c7\u6696\u8d39\u7701\u7ea630%\"\u7684\u91cd\u8981\u786c\u4ef6\u57fa\u7840\u4e4b\u4e00\u3002\u767d\u6676\u677f\u8fd8\u66f4\u6297\u538b\u3001\u9632\u6f6e\u3001\u73af\u4fdd\uff0c\u957f\u671f\u627f\u91cd\u4e0d\u53d8\u5f62\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u5730\u6696\u8054\u52a8\u63a7\u5236\u662f\u4ec0\u4e48\u539f\u7406\uff1f\u4e3a\u4ec0\u4e48\u80fd\u8282\u80fd\uff1f<\/div><div class=\"faq-a\">A\uff1a\u8054\u52a8\u63a7\u5236\u8ba9\u58c1\u6302\u7089\"\u6309\u9700\u542f\u505c\"\u2014\u2014\u5f53\u5404\u623f\u95f4\u5206\u5ba4\u6e29\u63a7\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6\u3001\u5168\u90e8\u56de\u8def\u9700\u6c42\u5f52\u96f6\u65f6\uff0c\u9505\u7089\u81ea\u52a8\u8fdb\u5165\u4f4e\u9891\u6216\u5f85\u673a\uff0c\u6d88\u9664\"\u623f\u95f4\u5df2\u70ed\u4f46\u9505\u7089\u8fd8\u5728\u70e7\"\u7684\u65e0\u6548\u4ea7\u70ed\u3002\u914d\u5408\u5206\u5ba4\u6e29\u63a7\uff08\u65e0\u4eba\u623f\u95f4\u5355\u72ec\u4f4e\u6e29\uff09\uff0c\u907f\u514d\u5168\u5c4b\u8fc7\u70e7\uff0c\u4ece\u800c\u6709\u673a\u4f1a\u964d\u4f4e\u7ea630%\u8fd0\u884c\u8d39\u7528\uff0c\u5b9e\u9645\u4ee5\u4f7f\u7528\u4e60\u60ef\u4e3a\u51c6\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u548c\u535a\u4e16\u51b7\u51dd\u7089\uff0c\u600e\u4e48\u6839\u636e\u5b9e\u9645\u9700\u6c42\u9009\uff1f<\/div><div class=\"faq-a\">A\uff1a\u4e24\u8005\u5747\u4e3a\u5fb7\u7cfb\u51b7\u51dd\u7089\u3002\u66fc\u745e\u5fb7L1PB24\u4f18\u52bf\u5728\u8c03\u8282\u6bd41:8\uff08\u4f4e\u9891\u66f4\u7a33\uff09\u3001\u70ed\u6c34\u4ea7\u738716L\/min\u3001APP\u8fdc\u7a0b+AI\u7701\u6c14+\u96f6\u51b7\u6c34+\u6545\u969c\u8bca\u65ad\u3001\u516b\u5e74\u4fdd\u4fee\uff1b\u535a\u4e16GC3260\u4f18\u52bf\u5728\u54c1\u724c\u77e5\u540d\u5ea6\uff08138\u5e74\uff09\u4e0e25kW\u529f\u7387\u7565\u5927\u3002\u672c\u6848\u4f8b\u770b\u91cd\u957f\u671f\u8282\u80fd\u4e0e\u667a\u80fd\u63a7\u5236\u9009\u66fc\u745e\u5fb7\uff1b\u82e5\u8ba4\u535a\u4e16\u54c1\u724c\u3001\u5bf9APP\u65e0\u9700\u6c42\uff0c\u53ef\u9009\u535a\u4e16+\u8282\u80fd\u5957\u9910\u540c\u914d\u7f6e\u3002\u4e24\u65b9\u6848\u9505\u7089\u5dee\u4ef7\u7ea62,000\u5143\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd175mm\u548c200mm\u6709\u4ec0\u4e48\u533a\u522b\uff1f\u5bc6\u94fa\u6709\u610f\u4e49\u5417\uff1f<\/div><div class=\"faq-a\">A\uff1a\u95f4\u8ddd\u8d8a\u5c0f\uff08\u5982175mm\uff09\u76d8\u7ba1\u66f4\u5bc6\u3001\u5355\u4f4d\u9762\u79ef\u6563\u70ed\u66f4\u5747\u5300\u3001\u5347\u6e29\u66f4\u5feb\uff0c\u4f46\u6750\u6599\u4e0e\u5de5\u65f6\u66f4\u591a\uff1b200mm\u5bc6\u94fa\u662f\u517c\u987e\u5747\u5300\u4e0e\u6210\u672c\u7684\u5e38\u7528\u6807\u51c6\uff0c\u5bf9135\u33a1\u5168\u5c4b\u5730\u6696\u5df2\u8db3\u591f\u5747\u5300\u3002\u672c\u6848\u4f8b\u91c7\u7528dn16 PE-RT\u76d8\u7ba1200mm\u5bc6\u94fa\uff0c\u914d\u5408\u767d\u6676\u677f3cm\uff0c\u6563\u70ed\u7a33\u5b9a\u3001\u811a\u611f\u8212\u9002\u3002\u7279\u6b8a\u533a\u57df\uff08\u5982\u5927\u9762\u79ef\u73bb\u7483\u5e55\u5899\u9644\u8fd1\uff09\u53ef\u6309\u9700\u5c40\u90e8\u52a0\u5bc6\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u6210\u90fd\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377\u6807\u51c6\u662f\u591a\u5c11\uff1f135\u33a1\u9700\u8981\u591a\u5927\u9505\u7089\uff1f<\/div><div class=\"faq-a\">A\uff1a\u6210\u90fd\u51ac\u5b63\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377\u901a\u5e38\u6309160W\/\u33a1\u53d6\u503c\u3002135\u33a1\u5168\u5c4b\u7ea6\u970021.6kW\uff0c\u9009\u752824kW\u51b7\u51dd\u7089\u5373\u5904\u4e8e\"\u9ec4\u91d1\u5339\u914d\u533a\u95f4\"\uff0c\u65e2\u80fd\u8986\u76d6\u6700\u51b7\u65e5\u6ee1\u8d1f\u8377\uff0c\u53c8\u56e0\u8c03\u8282\u6bd4\u5bbd\u3001\u65e5\u5e38\u4f4e\u9891\u66f4\u7701\u6c14\u3002\u76d8\u7ba1\u6309200mm\u5bc6\u94fa\u3001\u767d\u6676\u677f3cm\u4fdd\u6e29\uff0c\u8fdb\u4e00\u6b65\u964d\u4f4e\u70ed\u635f\u3001\u63d0\u5347\u8212\u9002\u5ea6\u3002<\/div><\/div>\n<\/section>\n\n<!-- \u5185\u94fe -->\n<section>\n  <h2>S7 \u00b7 \u540c\u7247\u533a\u6848\u4f8b\u4e0e\u65b9\u6848\u5e93<\/h2>\n  <div class=\"lm-links\">\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><div class=\"t\">\u9f99\u8109\u6696\u901a\u5b8c\u5de5\u6848\u4f8b\u5e93<\/div><div class=\"d\">\u6210\u90fd\u5168\u57df\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u5b9e\u666f\u6848\u4f8b\u805a\u5408<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=5849\" target=\"_blank\"><div class=\"t\">\u6696\u901a\u65b9\u6848\u5e93<\/div><div class=\"d\">\u5e73\u5c42\/\u522b\u5885\u591a\u7cfb\u7edf\u914d\u7f6e\u4e0e\u900f\u660e\u62a5\u4ef7\u53c2\u8003<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\"><div class=\"t\">\u5730\u6696\u77e5\u8bc6\u4e13\u9898<\/div><div class=\"d\">\u51b7\u51dd\u7089\/\u767d\u6676\u677f\/\u76d8\u7ba1\u95f4\u8ddd\u9009\u578b\u6307\u5357<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=3147\" target=\"_blank\"><div class=\"t\">\u58c1\u6302\u7089\u5730\u6696\u4e13\u9898<\/div><div class=\"d\">\u66fc\u745e\u5fb7\/\u535a\u4e16\u51b7\u51dd\u7089\u4e0e\u8282\u80fd\u5957\u9910\u5bf9\u6bd4<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\"><div class=\"t\">\u514d\u8d39\u52d8\u6d4b\u9884\u7ea6<\/div><div class=\"d\">\u6210\u90fd22\u5e74\u6388\u6743\u670d\u52a1\u5546\u4e0a\u95e8\u8d1f\u8377\u6d4b\u7b97<\/div><\/a>\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;margin:24px 0;\">\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13471\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;background:#fff;\">\u5730\u6696\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\uff1a\u4e94\u6b65\u6cd5\u516c\u5f00\u7248<\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=12439\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;background:#fff;\">\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66<\/a>\n<\/div>\n\n  <\/div>\n<\/section>\n\n<!-- CTA -->\n<div class=\"cta\">\n  <h3>\ud83d\udcde \u540c\u6237\u578b\u65b9\u6848\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h3>\n  <p>\u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u672c\u5730\u8fd0\u842522\u5e74\uff0c\u81ea\u6709\u552e\u540e\u56e2\u961f\uff0c\u65e5\u7acb\/\u66fc\u745e\u5fb7\u7b49\u54c1\u724c\u6388\u6743\u670d\u52a1\u5546\u3002<\/p>\n  <p>\u95e8\u5e97\uff1a\u2460 \u6210\u90fd\u9f99\u8109\u6696\u901a\u65d7\u8230\u5e97\u3000\u2461 \u9f99\u8109\u6696\u901a\u7279\u7ea6\u5b89\u88c5\u670d\u52a1\u4e2d\u5fc3<\/p>\n  <p>\u5ea7\u673a\uff1a<a href=\"tel:02861649321\">028-61649321<\/a>\u3000\u987e\u95ee\uff1a\u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a><\/p>\n  <p>\u670d\u52a1\u8303\u56f4\uff1a\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u4e0e\u6237\u578b\u65b9\u6848\u51fa\u5177\u3002<\/p>\n<\/div>\n\n<footer>\u00a9 \u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u672c\u6848\u4f8b\u542b\u540c\u6807\u51c6\u5de5\u827a\u793a\u610f\uff0c\u5177\u4f53\u4ee5\u5b8c\u5de5\u5b9e\u6d4b\u4e3a\u51c6<\/footer>\n<\/div>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a\",\n  \"description\": \"\u9f99\u8109\u6696\u901a\u843d\u5730\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u91c7\u6696\uff0c\u4e1a\u4e3b\u9009\u5b9a\u65b9\u6848\u4e09\u00b7\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u5957\u9910\uff0824kW\u51b7\u51dd\u7089+\u4f1f\u661f\u767d\u6676\u677f3cm+dn16\u76d8\u7ba1200mm\u5bc6\u94fa+\u5206\u5ba4\u6e29\u63a7\u8054\u52a8\uff09\uff1a\u5206\u5ba4\u72ec\u7acb\u63a7\u6e29\u3001\u9505\u7089\u6309\u9700\u542f\u505c\uff0c\u91c7\u6696\u8d39\u6bd4\u901a\u914d\u7701\u7ea630%\uff1b\u4e25\u683c\u6309GB50736\u4e0eJGJ142\u53cc\u56fd\u6807\u9a8c\u6536\uff0c\u6210\u90fd22\u5e74\u6388\u6743\u670d\u52a1\u5546\u514d\u8d39\u52d8\u6d4b\u3002\",\n  \"keywords\": \"\u9f99\u8109\u6696\u901a,\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696,\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b,135\u33a1\u5730\u6696,\u8282\u80fd\u5730\u6696\u5957\u9910,\u4f1f\u661f\u767d\u6676\u677f,\u5206\u5ba4\u6e29\u63a7\u8054\u52a8,\u6210\u90fd\u5730\u6696,\u51b7\u51dd\u7089\u9009\u578b\",\n  \"author\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\",\n    \"logo\": {\n      \"@type\": \"ImageObject\",\n      \"url\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-logo.png\"\n    }\n  },\n  \"about\": {\n    \"@type\": \"Thing\",\n    \"name\": \"\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696 135\u33a1\u5b8c\u5de5\u6848\u4f8b\"\n  },\n  \"articleSection\": \"\u6696\u901a\u6848\u4f8b\u5206\u4eab\"\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u51b7\u51dd\u7089\u548c\u666e\u901a\u58c1\u6302\u7089\u6709\u4ec0\u4e48\u533a\u522b\uff1f\u957f\u671f\u4f7f\u7528\u54ea\u4e2a\u66f4\u7701\u94b1\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u666e\u901a\u58c1\u6302\u7089\u70ed\u6548\u7387\u7ea690%\uff0c\u6392\u70df\u6e29\u5ea6\u9ad8\u3001\u4f59\u70ed\u6d6a\u8d39\uff1b\u51b7\u51dd\u7089\u56de\u6536\u70df\u6c14\u6f5c\u70ed\uff0c\u70ed\u6548\u7387\u53ef\u8fbe108%\u5de6\u53f3\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u8282\u7701\u7ea615\u201320%\u71c3\u6c14\u6d88\u8017\uff0c\u5b9e\u9645\u53d7\u4fdd\u6e29\u3001\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\u3001\u4e0d\u4f5c\u6bcf\u6237\u627f\u8bfa\u3002\u957f\u671f\u4f7f\u7528\uff0810\u201320\u5e74\uff09\u7701\u4e0b\u7684\u71c3\u6c14\u8d39\u901a\u5e38\u80fd\u8986\u76d6\u51b7\u51dd\u7089\u7684\u521d\u6295\u5dee\u4ef7\uff0c\u4e14\u66fc\u745e\u5fb7L1PB24\u63d0\u4f9b\u516b\u5e74\u4fdd\u4fee\uff0c\u540e\u671f\u7ef4\u4fee\u6210\u672c\u66f4\u4f4e\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5730\u6696\u4fdd\u6e29\u677f2cm\u548c3cm\u5dee\u8ddd\u5927\u5417\uff1f\u767d\u6676\u677f\u6709\u4ec0\u4e48\u4f18\u52bf\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5dee\u8ddd\u660e\u663e\u30022cm\u6324\u5851\u677f\u5411\u4e0b\u70ed\u635f\u8f83\u5927\uff0c3cm\u4f1f\u661f\u767d\u6676\u677f\u5bfc\u70ed\u7cfb\u6570\u66f4\u4f4e\u3001\u5411\u4e0b\u70ed\u635f\u66f4\u5c0f\uff0c\u66f4\u591a\u70ed\u91cf\u5411\u4e0a\u8fdb\u5165\u623f\u95f4\u3002\u5bf9135\u33a1\u5168\u5c4b\u5730\u6696\uff0c\u767d\u6676\u677f3cm\u914d\u5408\u955c\u9762\u94dd\u7b94\u53cd\u5c04\u819c\uff0c\u662f\u91c7\u6696\u8d39\u7701\u7ea630%\u7684\u91cd\u8981\u786c\u4ef6\u57fa\u7840\u4e4b\u4e00\u3002\u767d\u6676\u677f\u8fd8\u66f4\u6297\u538b\u3001\u9632\u6f6e\u3001\u73af\u4fdd\uff0c\u957f\u671f\u627f\u91cd\u4e0d\u53d8\u5f62\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5730\u6696\u8054\u52a8\u63a7\u5236\u662f\u4ec0\u4e48\u539f\u7406\uff1f\u4e3a\u4ec0\u4e48\u80fd\u8282\u80fd\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u8054\u52a8\u63a7\u5236\u8ba9\u58c1\u6302\u7089\u6309\u9700\u542f\u505c\u2014\u2014\u5f53\u5404\u623f\u95f4\u5206\u5ba4\u6e29\u63a7\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6\u3001\u5168\u90e8\u56de\u8def\u9700\u6c42\u5f52\u96f6\u65f6\uff0c\u9505\u7089\u81ea\u52a8\u8fdb\u5165\u4f4e\u9891\u6216\u5f85\u673a\uff0c\u6d88\u9664\u623f\u95f4\u5df2\u70ed\u4f46\u9505\u7089\u8fd8\u5728\u70e7\u7684\u65e0\u6548\u4ea7\u70ed\u3002\u914d\u5408\u5206\u5ba4\u6e29\u63a7\uff08\u65e0\u4eba\u623f\u95f4\u5355\u72ec\u4f4e\u6e29\uff09\uff0c\u907f\u514d\u5168\u5c4b\u8fc7\u70e7\uff0c\u4ece\u800c\u6709\u673a\u4f1a\u964d\u4f4e\u7ea630%\u8fd0\u884c\u8d39\u7528\uff0c\u5b9e\u9645\u4ee5\u4f7f\u7528\u4e60\u60ef\u4e3a\u51c6\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u548c\u535a\u4e16\u51b7\u51dd\u7089\uff0c\u600e\u4e48\u6839\u636e\u5b9e\u9645\u9700\u6c42\u9009\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e24\u8005\u5747\u4e3a\u5fb7\u7cfb\u51b7\u51dd\u7089\u3002\u66fc\u745e\u5fb7L1PB24\u4f18\u52bf\u5728\u8c03\u8282\u6bd41:8\uff08\u4f4e\u9891\u66f4\u7a33\uff09\u3001\u70ed\u6c34\u4ea7\u738716L\/min\u3001APP\u8fdc\u7a0b+AI\u7701\u6c14+\u96f6\u51b7\u6c34+\u6545\u969c\u8bca\u65ad\u3001\u516b\u5e74\u4fdd\u4fee\uff1b\u535a\u4e16GC3260\u4f18\u52bf\u5728\u54c1\u724c\u77e5\u540d\u5ea6\uff08138\u5e74\uff09\u4e0e25kW\u529f\u7387\u7565\u5927\u3002\u672c\u6848\u4f8b\u770b\u91cd\u957f\u671f\u8282\u80fd\u4e0e\u667a\u80fd\u63a7\u5236\u9009\u66fc\u745e\u5fb7\uff1b\u82e5\u8ba4\u535a\u4e16\u54c1\u724c\u3001\u5bf9APP\u65e0\u9700\u6c42\uff0c\u53ef\u9009\u535a\u4e16+\u8282\u80fd\u5957\u9910\u540c\u914d\u7f6e\u3002\u4e24\u65b9\u6848\u9505\u7089\u5dee\u4ef7\u7ea62,000\u5143\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd175mm\u548c200mm\u6709\u4ec0\u4e48\u533a\u522b\uff1f\u5bc6\u94fa\u6709\u610f\u4e49\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u95f4\u8ddd\u8d8a\u5c0f\uff08\u5982175mm\uff09\u76d8\u7ba1\u66f4\u5bc6\u3001\u5355\u4f4d\u9762\u79ef\u6563\u70ed\u66f4\u5747\u5300\u3001\u5347\u6e29\u66f4\u5feb\uff0c\u4f46\u6750\u6599\u4e0e\u5de5\u65f6\u66f4\u591a\uff1b200mm\u5bc6\u94fa\u662f\u517c\u987e\u5747\u5300\u4e0e\u6210\u672c\u7684\u5e38\u7528\u6807\u51c6\uff0c\u5bf9135\u33a1\u5168\u5c4b\u5730\u6696\u5df2\u8db3\u591f\u5747\u5300\u3002\u672c\u6848\u4f8b\u91c7\u7528dn16 PE-RT\u76d8\u7ba1200mm\u5bc6\u94fa\uff0c\u914d\u5408\u767d\u6676\u677f3cm\uff0c\u6563\u70ed\u7a33\u5b9a\u3001\u811a\u611f\u8212\u9002\u3002\u7279\u6b8a\u533a\u57df\uff08\u5982\u5927\u9762\u79ef\u73bb\u7483\u5e55\u5899\u9644\u8fd1\uff09\u53ef\u6309\u9700\u5c40\u90e8\u52a0\u5bc6\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6210\u90fd\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377\u6807\u51c6\u662f\u591a\u5c11\uff1f135\u33a1\u9700\u8981\u591a\u5927\u9505\u7089\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6210\u90fd\u51ac\u5b63\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377\u901a\u5e38\u6309160W\/\u33a1\u53d6\u503c\u3002135\u33a1\u5168\u5c4b\u7ea6\u970021.6kW\uff0c\u9009\u752824kW\u51b7\u51dd\u7089\u5373\u5904\u4e8e\u9ec4\u91d1\u5339\u914d\u533a\u95f4\uff0c\u65e2\u80fd\u8986\u76d6\u6700\u51b7\u65e5\u6ee1\u8d1f\u8377\uff0c\u53c8\u56e0\u8c03\u8282\u6bd4\u5bbd\u3001\u65e5\u5e38\u4f4e\u9891\u66f4\u7701\u6c14\u3002\u76d8\u7ba1\u6309200mm\u5bc6\u94fa\u3001\u767d\u6676\u677f3cm\u4fdd\u6e29\uff0c\u8fdb\u4e00\u6b65\u964d\u4f4e\u70ed\u635f\u3001\u63d0\u5347\u8212\u9002\u5ea6\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"\u9f99\u8109\u6696\u901a\",\n      \"item\": \"https:\/\/longmai-nt.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"\u6848\u4f8b\u5206\u4eab\",\n      \"item\": \"https:\/\/longmai-nt.com\/?page_id=2297\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\",\n      \"item\": \"https:\/\/longmai-nt.com\/?page_id=2297\"\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"LocalBusiness\",\n  \"name\": \"\u9f99\u8109\u6696\u901a\",\n  \"description\": \"\u6210\u90fd\u6388\u6743\u6696\u901a\u670d\u52a1\u5546\uff0c22\u5e74\u672c\u5730\u8fd0\u8425\uff0c\u63d0\u4f9b\u58c1\u6302\u7089\u5730\u6696\u4e0e\u4e2d\u592e\u7a7a\u8c03\u8bbe\u8ba1\u65bd\u5de5\u4e0e\u552e\u540e\u3002\",\n  \"telephone\": \"028-61649321\",\n  \"address\": {\n    \"@type\": \"PostalAddress\",\n    \"addressRegion\": \"\u6210\u90fd\",\n    \"addressCountry\": \"CN\"\n  },\n  \"areaServed\": \"\u6210\u90fd\",\n  \"url\": \"https:\/\/longmai-nt.com\"\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u203a \u6848\u4f8b\u5206\u4eab \u203a \u9526\u6c5f\u533a\u5854\u5b50\u5c71 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-11820","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u4e09\u5ba4\uff0c\u66fc\u745e\u5fb7L1PB24\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f3cm\u767d\u6676\u677f+200mm\u76d8\u7ba1\u5bc6\u94fa\uff0c\u5206\u5ba4\u6e29\u63a7\u9505\u7089\u8054\u52a8\u8282\u80fd\uff0c\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u6210\u90fd\u5730\u6696\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=11820\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u4e09\u5ba4\uff0c\u66fc\u745e\u5fb7L1PB24\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f3cm\u767d\u6676\u677f+200mm\u76d8\u7ba1\u5bc6\u94fa\uff0c\u5206\u5ba4\u6e29\u63a7\u9505\u7089\u8054\u52a8\u8282\u80fd\uff0c\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u6210\u90fd\u5730\u6696\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=11820\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-30T10:28:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820\",\"name\":\"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tfgywlc-lls-azzs.jpg\",\"datePublished\":\"2026-08-29T05:02:20+00:00\",\"dateModified\":\"2026-09-30T10:28:25+00:00\",\"description\":\"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u4e09\u5ba4\uff0c\u66fc\u745e\u5fb7L1PB24\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f3cm\u767d\u6676\u677f+200mm\u76d8\u7ba1\u5bc6\u94fa\uff0c\u5206\u5ba4\u6e29\u63a7\u9505\u7089\u8054\u52a8\u8282\u80fd\uff0c\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u6210\u90fd\u5730\u6696\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tfgywlc-lls-azzs.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tfgywlc-lls-azzs.jpg\",\"width\":1080,\"height\":1440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11820#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u4e09\u5ba4\uff0c\u66fc\u745e\u5fb7L1PB24\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f3cm\u767d\u6676\u677f+200mm\u76d8\u7ba1\u5bc6\u94fa\uff0c\u5206\u5ba4\u6e29\u63a7\u9505\u7089\u8054\u52a8\u8282\u80fd\uff0c\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u6210\u90fd\u5730\u6696\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=11820","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u4e09\u5ba4\uff0c\u66fc\u745e\u5fb7L1PB24\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f3cm\u767d\u6676\u677f+200mm\u76d8\u7ba1\u5bc6\u94fa\uff0c\u5206\u5ba4\u6e29\u63a7\u9505\u7089\u8054\u52a8\u8282\u80fd\uff0c\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u6210\u90fd\u5730\u6696\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=11820","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-09-30T10:28:25+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=11820","url":"https:\/\/longmai-nt.com\/?page_id=11820","name":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=11820#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=11820#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","datePublished":"2026-08-29T05:02:20+00:00","dateModified":"2026-09-30T10:28:25+00:00","description":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7135\u33a1\u4e09\u5ba4\uff0c\u66fc\u745e\u5fb7L1PB24\u51b7\u51dd\u7089\u5730\u6696\uff0c\u4f1f\u661f3cm\u767d\u6676\u677f+200mm\u76d8\u7ba1\u5bc6\u94fa\uff0c\u5206\u5ba4\u6e29\u63a7\u9505\u7089\u8054\u52a8\u8282\u80fd\uff0c\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u6210\u90fd\u5730\u6696\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=11820#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=11820"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=11820#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","width":1080,"height":1440},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=11820#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701-\u9f99\u8109\u6696\u901a"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11820","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11820"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11820\/revisions"}],"predecessor-version":[{"id":13483,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11820\/revisions\/13483"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11820"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}