{"id":11822,"date":"2026-08-29T13:15:42","date_gmt":"2026-08-29T05:15:42","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=11822"},"modified":"2026-10-28T16:27:08","modified_gmt":"2026-10-28T08:27:08","slug":"%e6%88%90%e9%83%bd%e6%88%90%e5%8d%8e%e5%8c%ba%e8%9e%8d%e5%88%9b%e7%8e%96%e5%8d%8e%e5%8f%b0114%e3%8e%a1%e5%9b%9b%e5%ae%a4%ef%bd%9c%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e8%8f%b2%e6%96%af%e6%9b%bc","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=11822","title":{"rendered":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a"},"content":{"rendered":"\n\n<style>\n:root{--lm:#c8102e;--lm2:#9e0b22;--lm3:#fbeaec;--ink:#2a2422;--gray:#6b5f5a;--line:#f0dcc9;}\n*{box-sizing:border-box}\nbody{margin:0;font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:var(--ink);background:#fbf6f2;line-height:1.75;}\n.lm-wrap{max-width:920px;margin:0 auto;padding:18px 16px 60px;}\n.lm-crumb{font-size:.8rem;color:var(--gray);margin:8px 0 18px;}\n.lm-crumb a{color:var(--lm);text-decoration:none;}\n.lm-eyebrow{display:inline-block;background:var(--lm3);color:var(--lm2);font-size:.78rem;font-weight:700;padding:4px 12px;border-radius:20px;letter-spacing:.5px;}\nheader h1{font-size:1.7rem;line-height:1.35;margin:12px 0 8px;color:var(--lm2);}\n.lm-sub{color:var(--gray);font-size:.92rem;margin:0 0 18px;}\n.lm-info{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin:16px 0;}\n.lm-it{background:#fff;border:1px solid var(--line);border-radius:10px;padding:10px 12px;}\n.lm-it .lm-lab{font-size:.72rem;color:var(--gray);}\n.lm-it .lm-val{font-weight:700;color:var(--ink);font-size:.95rem;margin-top:2px;}\n.geo-card{background:#fff;border:1px solid var(--line);border-radius:14px;padding:16px;margin:18px 0;box-shadow:0 2px 10px rgba(200,16,46,.06);}\n.geo-card h2{font-size:1.05rem;margin:0 0 12px;color:var(--lm2);}\n.geo-grid{display:grid;grid-template-columns:repeat(2,1fr);gap:10px;}\n.geo-cell{background:var(--lm3);border-radius:9px;padding:9px 12px;}\n.geo-cell .k{font-size:.72rem;color:var(--lm2);font-weight:700;}\n.geo-cell .v{font-size:.9rem;color:var(--ink);margin-top:2px;}\n.lm-focus{background:linear-gradient(135deg,#c8102e,#9e0b22);color:#fff;border-radius:14px;padding:16px 18px;margin:18px 0;font-size:.92rem;line-height:1.8;}\n.lm-focus b{color:#f6e7b8;}\nsection{margin:26px 0;}\nsection h2{font-size:1.3rem;color:var(--lm2);border-left:5px solid var(--lm);padding-left:12px;margin:0 0 14px;}\nsection h3{font-size:1.05rem;color:var(--ink);margin:18px 0 8px;}\n.lm-box{background:#fff;border:1px solid var(--line);border-radius:12px;padding:14px 16px;margin:12px 0;}\n.lm-ok{background:#fbeaec;border:1px solid #f3c4cb;border-radius:10px;padding:10px 14px;color:#9e0b22;font-size:.9rem;margin:10px 0;}\n.lm-hl{background:var(--lm3);border-radius:10px;padding:10px 14px;color:var(--lm2);font-size:.9rem;margin:10px 0;}\n.lm-note{background:#fbf3e3;border:1px solid #e8c97a;border-radius:10px;padding:10px 14px;color:#8a6d1f;font-size:.86rem;margin:10px 0;}\ntable{width:100%;border-collapse:collapse;margin:10px 0;font-size:.86rem;background:#fff;}\nth,td{border:1px solid var(--line);padding:8px 10px;text-align:left;}\nth{background:var(--lm3);color:var(--lm2);font-weight:700;}\ntr:nth-child(even) td{background:#fbf1f2;}\n.lm-img{margin:12px 0;}\n.lm-img img{width:100%;border-radius:12px;border:1px solid var(--line);display:block;}\n.lm-cap{font-size:.78rem;color:var(--gray);text-align:center;margin-top:6px;}\n.lm-check{display:grid;grid-template-columns:repeat(2,1fr);gap:10px;margin:12px 0;}\n.lm-check .c{background:#fff;border:1px solid var(--line);border-radius:10px;padding:10px 12px;font-size:.88rem;}\n.lm-check .c b{color:var(--lm2);}\n.faq{margin:12px 0;background:#fff;border:1px solid var(--line);border-radius:12px;padding:12px 16px;}\n.faq-q{font-weight:700;color:var(--lm2);}\n.faq-a{margin-top:6px;font-size:.92rem;color:var(--ink);}\n.lm-links{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0;}\n.lm-link{display:block;background:#fff;border:1px solid var(--line);border-radius:12px;padding:14px;color:var(--ink);text-decoration:none;transition:.2s;}\n.lm-link:hover{border-color:var(--lm);box-shadow:0 4px 14px rgba(200,16,46,.14);}\n.lm-link .t{font-weight:700;color:var(--lm2);font-size:.92rem;}\n.lm-link .d{font-size:.8rem;color:var(--gray);margin-top:4px;}\n.cta{background:linear-gradient(135deg,#c8102e,#9e0b22);color:#fff;border-radius:16px;padding:20px 22px;margin:24px 0;}\n.cta h3{color:#fff;margin:0 0 10px;}\n.cta p{margin:6px 0;font-size:.92rem;}\n.cta a{color:#f6e7b8;font-weight:700;}\nfooter{text-align:center;color:var(--gray);font-size:.78rem;margin-top:30px;}\n@media(max-width:680px){\n .lm-info{grid-template-columns:repeat(2,1fr);}\n .geo-grid{grid-template-columns:1fr;}\n .lm-check{grid-template-columns:1fr;}\n .lm-links{grid-template-columns:1fr;}\n header h1{font-size:1.4rem;}\n}\n<\/style>\n\n<div class=\"lm-wrap\">\n<nav class=\"lm-crumb\"><a href=\"https:\/\/longmai-nt.com\" target=\"_blank\">\u9f99\u8109\u6696\u901a<\/a> \u203a \u6848\u4f8b\u5206\u4eab \u203a \u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0\uff08\u56db\u5ba4\u4e24\u5385 \u00b7 \u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u83f2\u65af\u66fc\u5730\u6696\uff09<\/nav>\n\n<header>\n  <div class=\"lm-eyebrow\">\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b \u00b7 \u56db\u5ba4\u4e24\u5385 \u00b7 \u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u83f2\u65af\u66fc\u5730\u6696<\/div>\n  <h1>\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a<\/h1>\n  <p class=\"lm-sub\">\u56db\u5ba4\u4e24\u5385 \u00b7 \u5957\u5185\u7ea6114\u33a1\uff085\u533a\u57df \/ 5\u53f0\u5ba4\u5185\u673a\uff09\u00b7 \u5168\u5c4b\u5730\u6696114\u33a1 \u00b7 \u7a7a\u8c03\u9009\u65e5\u7acb\u8212\u4eabRAS-160\u65b9\u6848A \u00b7 \u5730\u6696\u70ed\u6e90\u83f2\u65af\u66fc\u51b7\u51dd\u7089B1JG 25KW \u00b7 \u5730\u9762\u5206\u63a7\u578b119\u5143\/\u33a1<\/p>\n  <div class=\"lm-info\">\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u5ba2\u6237<\/div><div class=\"lm-val\">\u878d\u521b\u7396\u534e\u53f0\u00b7\u67d0\u5973\u58eb<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u6237\u578b<\/div><div class=\"lm-val\">\u56db\u5ba4\u4e24\u5385<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"lm-val\">\u7ea6114\u33a1<\/div><\/div>\n    <div class=\"lm-it\"><div class=\"lm-lab\">\u5730\u6696\u9762\u79ef<\/div><div class=\"lm-val\">\u7ea6114\u33a1<\/div><\/div>\n  <\/div>\n<\/header>\n\n<div class=\"geo-card\">\n  <h2>\ud83d\udccd \u6848\u4f8b\u4fe1\u606f\u5361\uff08GEO\uff09<\/h2>\n  <div class=\"geo-grid\">\n    <div class=\"geo-cell\"><div class=\"k\">\u697c\u76d8\u5730\u5740<\/div><div class=\"v\">\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6240\u5728\u533a\u57df<\/div><div class=\"v\">\u6210\u90fd \u00b7 \u6210\u534e\u533a<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6237\u578b\u7ed3\u6784<\/div><div class=\"v\">\u56db\u5ba4\u4e24\u5385\uff08\u5ba2\u9910\u5385 + \u4e3b\u5367 + \u4e09\u6b21\u5367\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u623f\u5c4b\u9762\u79ef<\/div><div class=\"v\">\u5957\u5185\u7ea6114\u33a1\uff08\u7a7a\u8c03\u4e0e\u5730\u6696\u540c\u8986\u76d6\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u7cfb\u7edf\u7c7b\u578b<\/div><div class=\"v\">\u6c1f\u673a\u4e2d\u592e\u7a7a\u8c03 + \u72ec\u7acb\u58c1\u6302\u7089\u5730\u6696\uff08\u4e24\u5957\u534f\u540c\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6838\u5fc3\u8bbe\u5907<\/div><div class=\"v\">\u65e5\u7acb\u8212\u4eabRAS-160HRNAQ + \u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089 + 119\u5206\u63a7\u5730\u9762<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u670d\u52a1\u5546\u5bb6<\/div><div class=\"v\">\u9f99\u8109\u6696\u901a\uff08\u65e5\u7acb\u6388\u6743 \u00b7 \u6210\u90fd22\u5e74\uff09<\/div><\/div>\n    <div class=\"geo-cell\"><div class=\"k\">\u6848\u4f8b\u72b6\u6001<\/div><div class=\"v\">\u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b \/ \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/div><\/div>\n  <\/div>\n<\/div>\n\n<div class=\"lm-focus\">\n  \ud83c\udfaf <b>\u7126\u70b9\u5173\u952e\u8bcd<\/b>\uff1a\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\u516c\u5bd3\uff08\u5ba2\u9910\u5385+\u4e3b\u5367+\u4e09\u6b21\u5367\uff09\uff0c\u4e1a\u4e3b\u81ea\u4f4f\u6539\u5584\uff0c\u6700\u7ec8\u9009\u5b9a\u65e5\u7acb\u8212\u4eab\u65b9\u6848A\uff08RAS-160HRNAQ\u4e3b\u673a + 5\u53f0\u5ba4\u5185\u673a\uff1a\u5ba2\u9910\u538590\u578b9.0kW\u3001\u4e3b\u536736\u3001\u6b21\u5367A22\u3001\u6b21\u5367B18\u3001\u6b21\u5367C18\uff0c\u603b\u5bb9\u91cf18.4kW\uff0c160\u4e3b\u673a\u8d85\u914d\u7387\u7ea6118.7%\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u5408\u89c4\u533a\u95f4\uff09\u642d\u914d\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089\u72ec\u7acb\u5730\u6696\uff08\u5730\u9762\u9009\u5206\u63a7\u578b119\u5143\/\u33a1\uff09\u3002\u672c\u6848\u4f8b\u7531\u9f99\u8109\u6696\u901a\uff08\u6210\u90fd22\u5e74\u65e5\u7acb\u6388\u6743\u670d\u52a1\u5546\uff09\u8bbe\u8ba1\u65bd\u5de5\uff0c\u4e25\u683c\u6309GB50736\u4e0eJGJ142\u53cc\u56fd\u6807\u9a8c\u6536\uff0c\u5168\u5c4b\u5236\u51b7\u5236\u70ed\u4e0e\u51ac\u5b63\u5730\u6696\u534f\u540c\u8212\u9002\uff0c\u9002\u5408\u6210\u90fd\u6e7f\u51b7\u6c14\u5019\u4e0b\u7684\u591a\u5ba4\u81ea\u4f4f\u5bb6\u5ead\u53c2\u8003\u3002\n<\/div>\n\n<!-- S1 -->\n<section>\n  <h2>S1 \u00b7 \u5ba2\u6237\u9700\u6c42\u4e0e\u6237\u578b\u8bca\u65ad<\/h2>\n  <h3>1.1 \u6237\u578b\u5404\u533a\u57df\u660e\u7ec6<\/h3>\n  <div class=\"lm-box\">\n    <table>\n      <tr><th>\u533a\u57df<\/th><th>\u9762\u79ef\u7ea6(\u33a1)<\/th><th>\u529f\u80fd\u5b9a\u4f4d<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385<\/td><td>\u224856.3<\/td><td>\u4f1a\u5ba2 \/ \u7528\u9910\u6838\u5fc3\u533a<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>\u224822.5<\/td><td>\u4e3b\u4eba\u4f11\u606f<\/td><\/tr>\n      <tr><td>\u6b21\u5367A<\/td><td>\u224813.8<\/td><td>\u957f\u8f88 \/ \u5ba2\u5367<\/td><\/tr>\n      <tr><td>\u6b21\u5367B<\/td><td>\u224811.3<\/td><td>\u513f\u7ae5 \/ \u5ba2\u5367<\/td><\/tr>\n      <tr><td>\u6b21\u5367C<\/td><td>\u224811.3<\/td><td>\u4e66\u623f \/ \u5ba2\u5367<\/td><\/tr>\n      <tr style=\"background:#fbf1f2;font-weight:700\"><td>\u5408\u8ba1<\/td><td>\u2248115\uff08\u5957\u5185\u7ea6114\uff09<\/td><td>\u56db\u5ba4\u4e24\u5385 \u00b7 \u7a7a\u8c03\u4e0e\u5730\u6696\u540c\u8986\u76d6<\/td><\/tr>\n    <\/table>\n    <div class=\"lm-note\">\ud83d\udcdd \u5404\u533a\u57df\u9762\u79ef\u6309160W\/\u33a1\u8bbe\u8ba1\u6807\u51c6\u53cd\u7b97\uff08\u51b7\u91cf\u00f70.16\uff09\uff0c\u5408\u8ba1\u7ea6115\u33a1\uff0c\u4e0e\u65b9\u6848\u4e66\u91c7\u6696114\u33a1\u57fa\u672c\u4e00\u81f4\uff1b\u6700\u7ec8\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002<\/div>\n  <\/div>\n  <h3>1.2 \u5404\u533a\u57df\u7a7a\u8c03\u51b7\u8d1f\u8377\uff08\u6309160W\/\u33a1\u8bbe\u8ba1\u6807\u51c6\uff09<\/h3>\n  <div class=\"lm-box\">\n    <table>\n      <tr><th>\u533a\u57df<\/th><th>\u9762\u79ef(\u33a1)<\/th><th>\u8bbe\u8ba1\u8d1f\u8377(160W\/\u33a1)<\/th><th>\u9009\u578b\u5bb9\u91cf<\/th><th>\u4f59\u91cf<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385<\/td><td>\u224856.3<\/td><td>9.0kW<\/td><td>90\u578b=9.0<\/td><td>\u5145\u8db3<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>\u224822.5<\/td><td>3.6kW<\/td><td>36<\/td><td>\u4f59\u91cf<\/td><\/tr>\n      <tr><td>\u6b21\u5367A<\/td><td>\u224813.8<\/td><td>2.2kW<\/td><td>22<\/td><td>\u4f59\u91cf<\/td><\/tr>\n      <tr><td>\u6b21\u5367B<\/td><td>\u224811.3<\/td><td>1.8kW<\/td><td>18<\/td><td>\u4f59\u91cf<\/td><\/tr>\n      <tr><td>\u6b21\u5367C<\/td><td>\u224811.3<\/td><td>1.8kW<\/td><td>18<\/td><td>\u4f59\u91cf<\/td><\/tr>\n    <\/table>\n    <div class=\"lm-ok\">\u2713 \u5168\u5c4b\u5171<b>5\u53f0\u5ba4\u5185\u673a<\/b>\u3001\u603b\u5bb9\u91cf18.4\uff1b160\u4e3b\u673a\u8d85\u914d\u7387 = 18.4 \u00f7 15.5 \u2248 <b>118.7%<\/b>\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u8303\u56f4\u5185\uff0c\u65e5\u5e38\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u4f18\u3001\u591a\u5f00\u4e5f\u4e0d\u5e26\u4e0d\u52a8\u3002<\/div>\n  <\/div>\n  <h3>1.3 \u6838\u5fc3\u8bc9\u6c42\u4e0e\u75db\u70b9<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4e1a\u4e3b\u5bf9\u8fd9\u5957\u56db\u5ba4\u4e24\u5385\u7684\u6838\u5fc3\u8bc9\u6c42\u5f88\u660e\u786e\uff1a<b>\u590f\u5929\u5236\u51b7\u3001\u51ac\u5929\u5236\u70ed+\u5730\u6696\u3001\u9884\u7b97\u53ef\u63a7\u3001\u914d\u7f6e\u52a1\u5b9e\u3001\u6210\u90fd\u672c\u5730\u552e\u540e\u53ef\u9760<\/b>\u3002\u75db\u70b9\u96c6\u4e2d\u5728\u4e09\u70b9\uff1a<\/p>\n    <p>\u2460 \u56db\u5ba4\u591a\u5367\uff08\u4e3b\u5367+\u4e09\u6b21\u5367\uff09\u9700\u5206\u522b\u72ec\u7acb\u63a7\u6e29\uff0c\u907f\u514d\u6709\u4eba\u7761\u89c9\u6709\u4eba\u6d3b\u52a8\u7684\u76f8\u4e92\u5e72\u6270\uff1b<br>\n    \u2461 \u6210\u90fd\u51ac\u5b63\u6e7f\u51b7\uff0c\u4ec5\u9760\u7a7a\u8c03\u5236\u70ed\u811a\u5e95\u51b0\u51c9\uff0c\u9700\u8981\u72ec\u7acb\u5730\u6696\u8865\u8db3\"\u6e29\u8db3\u51c9\u9876\"\uff1b<br>\n    \u2462 \u65b9\u6848A\uff08\u8212\u4eab+\u58c1\u6302\u7089\uff09\u4e0e\u65b9\u6848B\uff08\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff09\u53c2\u6570\u590d\u6742\uff0c\u62c5\u5fc3\u9009\u9519\u3001\u603b\u4ef7\u4e0d\u900f\u660e\u3002<\/p>\n    <div class=\"lm-hl\">\ud83d\udca1 <b>\u672c\u5730\u6c14\u5019\u6ce8\u89e3<\/b>\uff1a\u6210\u534e\u533a\u5c5e\u6210\u90fd\u5178\u578b\u6e7f\u51b7\u6c14\u5019\uff0c\u51ac\u5b63\u9634\u51b7\u671f\u957f\u3001\u590f\u5b63\u95f7\u70ed\uff0c\u672c\u5957\u65b9\u6848\u8d1f\u8377\u53d6\u503c\u5145\u5206\u8003\u8651\u533a\u57df\u56f4\u62a4\u7ed3\u6784\u7279\u70b9\uff0c\u5236\u51b7\u5236\u70ed\u5747\u7559\u5b89\u5168\u88d5\u5ea6\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S2 -->\n<section>\n  <h2>S2 \u00b7 \u8bbe\u8ba1\u65b9\u6848\u4e0e\u8bbe\u5907\u914d\u7f6e<\/h2>\n  <h3>2.1 \u7cfb\u7edf\u539f\u7406\uff1a\u6c1f\u673a\u7a7a\u8c03 + \u72ec\u7acb\u58c1\u6302\u7089\u5730\u6696\uff0c\u4e24\u5957\u534f\u540c<\/h3>\n  <div class=\"lm-box\">\n    <p><b>\u2460 \u7a7a\u8c03\u7cfb\u7edf\uff08\u5236\u51b7\u5236\u70ed\u4e24\u7528\uff09<\/b>\uff1a\u65e5\u7acb\u8212\u4eab\u4e3a<b>\u70ed\u6cf5\u578b\u6c1f\u673a\u4e2d\u592e\u7a7a\u8c03<\/b>\u2014\u2014\u590f\u5929\u628a\u5ba4\u5185\u70ed\u91cf\u642c\u5230\u5ba4\u5916\uff08\u5236\u51b7\uff09\uff0c\u51ac\u5929\u53cd\u5411\u628a\u5ba4\u5916\u70ed\u91cf\u642c\u5230\u5ba4\u5185\uff08\u5236\u70ed\uff09\uff0c\u4e00\u53f0\u8bbe\u5907\u517c\u987e\u51b7\u6696\uff0c\u5ba4\u5185\u673a\u901a\u8fc7\u51b7\u5a92\u76f4\u63a5\u6362\u70ed\u3002<\/p>\n    <p><b>\u2461 \u5730\u6696\u7cfb\u7edf\uff08\u72ec\u7acb\u58c1\u6302\u7089\uff09<\/b>\uff1a\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089\u71c3\u70e7\u4ea7\u70ed\u6c34\uff0c\u9001\u5165\u5730\u6696\u76d8\u7ba1\u8f90\u5c04\u4f9b\u70ed\uff0c\u4e13\u53f8\u51ac\u5b63\u8db3\u5e95\u6e29\u6696\uff1b\u4e0e\u7a7a\u8c03\u4e3b\u673a\u4e92\u4e0d\u5e72\u6d89\uff0c\u7ef4\u62a4\u8fb9\u754c\u6e05\u6670\u3002<\/p>\n    <div class=\"lm-ok\">\u2713 \u7a7a\u8c03\u8d1f\u8d23\u5feb\u901f\u51b7\u6696\u4e0e\u65e5\u5e38\uff0c\u5730\u6696\u4e13\u53f8\u51ac\u5b63\u8db3\u5e95\u6e29\u6696\uff0c\u4e8c\u8005\u534f\u540c\u5b9e\u73b0\"\u6e29\u8db3\u51c9\u9876\"\u7684\u8212\u9002\u4f53\u611f\uff0c\u4e14\u4efb\u4e00\u7cfb\u7edf\u68c0\u4fee\u4e0d\u5f71\u54cd\u53e6\u4e00\u7cfb\u7edf\u3002<\/div>\n  <\/div>\n  <h3>2.2 \u7a7a\u8c03\u7cfb\u7edf\u914d\u7f6e \u00b7 \u65e5\u7acb\u8212\u4eab RAS-160 \u65b9\u6848A<\/h3>\n  <div class=\"lm-box\">\n    <table>\n      <tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5ba4\u5185\u673a\u578b\u53f7\/\u5bb9\u91cf<\/th><th>\u6570\u91cf<\/th><th>\u9009\u578b\u8bf4\u660e<\/th><\/tr>\n      <tr><td>\u5ba2\u9910\u5385<\/td><td>\u224856.3\u33a1<\/td><td>RPIZ-90FSVNZQD\/P(9.0kW)<\/td><td>1<\/td><td>\u5927\u7a7a\u95f4\u5355\u53f0\u9ad8\u6548\u8986\u76d6<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>\u224822.5\u33a1<\/td><td>RPIZ-36FSNAQD\/P(3.6kW)<\/td><td>1<\/td><td>\u9759\u97f3\u4f18\u5148<\/td><\/tr>\n      <tr><td>\u6b21\u5367A<\/td><td>\u224813.8\u33a1<\/td><td>RPIZ-22FSNAQD\/P(2.2kW)<\/td><td>1<\/td><td>\u72ec\u7acb\u63a7\u6e29<\/td><\/tr>\n      <tr><td>\u6b21\u5367B<\/td><td>\u224811.3\u33a1<\/td><td>RPIZ-18FSNAQD\/P(1.8kW)<\/td><td>1<\/td><td>\u72ec\u7acb\u63a7\u6e29<\/td><\/tr>\n      <tr><td>\u6b21\u5367C<\/td><td>\u224811.3\u33a1<\/td><td>RPIZ-18FSNAQD\/P(1.8kW)<\/td><td>1<\/td><td>\u5065\u5eb7\u9001\u98ce<\/td><\/tr>\n      <tr style=\"background:#fbf1f2;font-weight:700\"><td>\u5408\u8ba1<\/td><td>\u2248114\u33a1<\/td><td>5\u53f0\u5ba4\u5185\u673a \u00b7 \u603b\u5bb9\u91cf18.4kW<\/td><td>5\u53f0<\/td><td>160\u4e3b\u673a\u8d85\u914d\u7387\u7ea6118.7%<\/td><\/tr>\n    <\/table>\n    <p style=\"margin:8px 0 0\"><b>\u4e3b\u673a<\/b>\uff1a\u65e5\u7acb\u8212\u4eab RAS-160HRNAQ\uff0815.5kW \/ 6\u5339\uff09\u00b7 <b>\u5185\u673a<\/b>\uff1aDC\u8584\u578b\u6807\u51c6\u5185\u673a\uff0c\u51715\u53f0\u3001\u603b\u5bb9\u91cf18.4kW\u3002<\/p>\n    <div class=\"lm-ok\">\u2713 5\u53f0\u5ba4\u5185\u673a\u603b\u5bb9\u91cf18.4kW\uff1b160\u4e3b\u673a\u8d85\u914d\u7387\u2248118.7%\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u5408\u89c4\u533a\u95f4\u5185\uff0c\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u4f18\u3001\u65e5\u5e38\u591a\u5f00\u4e5f\u4e0d\u5e26\u4e0d\u52a8\u3002<\/div>\n  <\/div>\n  <h3>2.3 \u5730\u6696\u7cfb\u7edf\u914d\u7f6e \u00b7 \u83f2\u65af\u66fc\u51b7\u51dd\u7089 + \u5206\u63a7\u578b\u5730\u9762<\/h3>\n  <div class=\"lm-box\">\n    <table>\n      <tr><th>\u9879\u76ee<\/th><th>\u914d\u7f6e<\/th><\/tr>\n      <tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>\u7ea6114\u33a1\uff08\u5168\u5c4b\u5730\u6696\uff09<\/td><\/tr>\n      <tr><td>\u70ed\u6e90<\/td><td>\u83f2\u65af\u66fc B1JG 25KW \u51b7\u51dd\u7089<\/td><\/tr>\n      <tr><td>\u8f93\u914d<\/td><td>\u5730\u6696\u76d8\u7ba1 + \u667a\u80fd\u5206\u96c6\u6c34\u5668 + \u4fdd\u6e29\u5c42<\/td><\/tr>\n      <tr><td>\u672b\u7aef<\/td><td>\u5730\u6696\u76d8\u7ba1\uff08\u5730\u9762\u8f90\u5c04\uff09<\/td><\/tr>\n      <tr><td>\u63a7\u5236<\/td><td>\u58c1\u6302\u7089\u6e29\u63a7\u8054\u52a8 + \u5206\u5ba4\u6e29\u63a7<\/td><\/tr>\n      <tr><td>\u5730\u9762\u6863\u4f4d<\/td><td>\u5206\u63a7\u578b 119\u5143\/\u33a1\uff08\u91c7\u6696114\u33a1\uff0c\u5404\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\uff09<\/td><\/tr>\n    <\/table>\n    <div class=\"lm-hl\">\ud83c\udfaf \u5730\u9762\u4e09\u6863\u5bf9\u6bd4\uff1a\u7ecf\u6d4e\u578b99 \/ \u5206\u63a7\u578b119 \/ \u8282\u80fd\u8bbe\u8ba1169\u5143\/\u33a1\u3002\u4e1a\u4e3b\u9009\u5b9a<b>\u5206\u63a7\u578b119\u5143\/\u33a1<\/b>\u2014\u2014\u5404\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\u3001\u6027\u4ef7\u6bd4\u4e0e\u7ba1\u63a7\u5e73\u8861\u4e4b\u9009\uff1b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u5b9e\u9645\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002<\/div>\n  <\/div>\n  <h3>2.4 \u6267\u884c\u6807\u51c6 \u00b7 \u53cc\u56fd\u6807\u5f15\u7528<\/h3>\n  <div class=\"lm-box\">\n    <p>\u672c\u65b9\u6848\u8d1f\u8377\u8ba1\u7b97\u4e0e\u7cfb\u7edf\u8bbe\u8ba1\u4e25\u683c\u53c2\u7167\u56fd\u5bb6\u73b0\u884c\u6807\u51c6\uff1a<\/p>\n    <p>\u00b7 <b>GB 50736\u20112012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/b>\u2014\u2014\u7a7a\u8c03\u51b7\u70ed\u8d1f\u8377\u3001\u6c14\u6d41\u7ec4\u7ec7\u4e0e\u7cfb\u7edf\u9009\u578b\u4f9d\u636e\uff1b<br>\n    \u00b7 <b>JGJ 142\u20112012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/b>\u2014\u2014\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\u3001\u5206\u96c6\u6c34\u5668\u4e0e\u56de\u586b\u5de5\u827a\u4f9d\u636e\u3002<\/p>\n    <div class=\"lm-note\">\ud83d\udcdd \u4e2d\u592e\u7a7a\u8c03\u4e0e\u72ec\u7acb\u5730\u6696\u5747\u5c5e\u53d7\u76d1\u5de5\u7a0b\uff0c\u5b89\u88c5\u5de5\u827a\u4e0e\u9a8c\u6536\u987b\u843d\u5230\u73b0\u573a\u6bcf\u4e00\u6b65\uff0c\u8be6\u89c12.5\u3002<\/div>\n  <\/div>\n  <h3>2.5 \u65bd\u5de5\u9a8c\u6536\u8981\u70b9\uff084\u9879\uff09<\/h3>\n  <div class=\"lm-check\">\n    <div class=\"c\"><b>\u2460 \u51b7\u5a92\u7ba1\u8def<\/b>\uff1a\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5 + \u4fdd\u538b\u68c0\u6f0f\uff0c\u675c\u7edd\u6c27\u5316\u76ae\u4e0e\u6162\u6f0f\u3002<\/div>\n    <div class=\"c\"><b>\u2461 \u5730\u6696\u76d8\u7ba1<\/b>\uff1a\u6c34\u538b0.6MPa\u4fdd\u538b24h\u65e0\u6e17\u6f0f\uff0c\u76d8\u7ba1\u65e0\u63a5\u5934\u660e\u8bbe\u3002<\/div>\n    <div class=\"c\"><b>\u2462 \u8054\u52a8\u8c03\u8bd5<\/b>\uff1a\u5206\u96c6\u6c34\u5668\u4e0e\u58c1\u6302\u7089\u8054\u52a8\u3001\u5206\u5ba4\u6e29\u63a7\u6821\u51c6\uff0c\u542f\u505c\u7a33\u5b9a\u3002<\/div>\n    <div class=\"c\"><b>\u2463 \u5185\u673a\u540a\u88c5<\/b>\uff1a\u6c34\u5e73\u5ea6\u4e0e\u51b7\u51dd\u6c34\u6392\u6c34\u5761\u5ea6\u9a8c\u6536\uff0c\u675c\u7edd\u6ef4\u6c34\u4e0e\u5f02\u54cd\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S3 -->\n<section>\n  <h2>S3 \u00b7 \u65bd\u5de5\u5de5\u827a\u6807\u51c6<\/h2>\n  <h3>3.1 \u9f99\u8109\u7cbe\u5de5\u5de5\u827a\u8981\u70b9<\/h3>\n  <div class=\"lm-box\">\n    <p>\u672c\u6848\u4f8b\u6cbf\u7528\u9f99\u8109\u6696\u901a\u7edf\u4e00\u7cbe\u5de5\u5de5\u827a\uff1a\u8f85\u6750\u8fdb\u573a\u9a8c\u6536 \u2192 \u51b7\u5a92\u7ba1\u8def\u5b89\u88c5\uff08\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff09\u2192 \u5ba4\u5185\u673a\u540a\u88c5\uff08\u6c34\u5e73\u6821\u51c6\uff09\u2192 \u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\uff08\u5206\u96c6\u6c34\u5668\u5b9a\u4f4d\uff09\u2192 \u5206\u5ba4\u8c03\u8bd5\u3002\u6bcf\u4e00\u6b65\u5747\u6309\u53cc\u56fd\u6807\u4e0e\u5382\u5bb6\u5de5\u827a\u624b\u518c\u6267\u884c\uff0c\u5173\u952e\u8282\u70b9\u7559\u75d5\u5f52\u6863\u3002<\/p>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u8f85\u6750\u8fdb\u573a\u9a8c\u6536\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u4e0e\u83f2\u65af\u66fc\u5730\u6696\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-gdaz.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u51b7\u5a92\u7ba1\u8def\u4e0e\u5730\u6696\u76d8\u7ba1\u5b89\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03\u53ca\u83f2\u65af\u66fc\u5730\u6696\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-cxglf.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\u51b7\u5a92\u7ba1\u8def\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n  <\/div>\n<\/section>\n\n<!-- S4 -->\n<section>\n  <h2>S4 \u00b7 \u65bd\u5de5\u5b9e\u666f\u56fe\u96c6<\/h2>\n  <h3>4.1 \u5173\u952e\u8282\u70b9\u5b9e\u666f<\/h3>\n  <div class=\"lm-box\">\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-dnxkqaz.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5ba4\u5185\u673a\u540a\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eabDC\u8584\u578b\u6807\u51c6\u5185\u673a\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-01.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5ba4\u5185\u673a\u4e0e\u6392\u98ce\u8bbe\u5907\u5b89\u88c5\u5b9e\u666f\uff0c\u65e5\u7acb\u8212\u4eab\u6807\u51c6\u5185\u673a\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u4e0e\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5b9e\u666f\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u5de5\u5730\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-pyk.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5730\u6696\u76d8\u7ba1\u76d8\u7ed5\u5b9e\u666f\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n      <div class=\"lm-img\">\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-ydaz.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u58c1\u6302\u7089\u4e0e\u672b\u7aef\u8bbe\u5907\u5b89\u88c5\u5b9e\u666f\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u540c\u6807\u51c6\u5de5\u827a\">\n        <div class=\"lm-cap\">\u540c\u6807\u51c6\u5de5\u827a\u5b9e\u666f\uff08\u975e\u672c\u6848\u5b9e\u666f\uff09<\/div>\n      <\/div>\n    <div class=\"lm-note\">\ud83d\udcdd \u56fe\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6807\u51c6\u7cbe\u5de5\u5de5\u827a\u793a\u610f\uff1b\u672c\u6848\u5b8c\u5de5\u5b9e\u62cd\u56fe\u7531\u4e1a\u4e3b\u6388\u6743\u540e\u5f52\u6863\u66ff\u6362\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- S5 -->\n<section>\n  <h2>S5 \u00b7 \u6548\u679c\u5bf9\u6bd4\u4e0e\u5ba2\u6237\u53cd\u9988<\/h2>\n  <h3>5.1 \u5b8c\u5de5\u4f53\u611f\u5bf9\u6807<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u540c\u6237\u578b\u5b8c\u5de5\u6848\u4f8b\u5bf9\u6807\u4f53\u611f\uff0c<b>\u672c\u6237\u5b9e\u9645\u6548\u679c\u4ee5\u5b8c\u5de5\u8c03\u8bd5\u540e\u7684\u73b0\u573a\u5b9e\u6d4b\u4e3a\u51c6<\/b>\u3002<\/p>\n    <p><b>\u5236\u51b7<\/b>\uff1a\u5f00\u673a\u7ea615\u201120\u5206\u949f\u5ba4\u6e29\u964d\u81f3\u8bbe\u5b9a\u503c\uff0c\u6c1f\u673a\u54cd\u5e94\u5feb\u3001\u51fa\u98ce\u67d4\u548c\u4e0d\u5e72\u71e5\uff1b\u5ba2\u9910\u538590\u578b\u5355\u5185\u673a\u9ad8\u6548\u8986\u76d6\u5927\u7a7a\u95f4\u3002<br>\n    <b>\u5236\u70ed<\/b>\uff1a\u7a7a\u8c03\u5feb\u901f\u8865\u6e29\uff0c\u51ac\u5b63\u5730\u6696\u5f00\u542f\u540e\u8db3\u5e95\u6e29\u6696\u3001\u9876\u51c9\u811a\u6696\uff0c\u6e7f\u51b7\u5929\u6c14\u4f53\u611f\u660e\u663e\u63d0\u5347\u3002<br>\n    <b>\u9759\u97f3<\/b>\uff1aDC\u8584\u578b\u5185\u673a\u6700\u4f4e\u7ea617\u5206\u8d1d\u8fd0\u884c\uff0c\u4e3b\u5367\u4f11\u606f\u4e0d\u53d7\u6270\u3002<\/p>\n  <\/div>\n  <h3>5.2 \u4e1a\u4e3b\u9009\u578b\u7406\u7531\uff08\u65b9\u6848A\uff09<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4e1a\u4e3b\u5728\u65b9\u6848A\uff08\u8212\u4eab+\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff09\u4e0e\u65b9\u6848B\uff08\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\u4e24\u8054\u4f9b\uff09\u95f4\u6700\u7ec8\u9009\u5b9a<b>\u65b9\u6848A<\/b>\uff0c\u6838\u5fc3\u7406\u7531\uff1a<\/p>\n    <p>\u2460 <b>\u9884\u7b97\u53ef\u63a7<\/b>\uff1a\u521d\u671f\u6295\u5165\u4f4e\u4e8e\u4e24\u8054\u4f9b\u65b9\u6848\uff0c\u6027\u4ef7\u6bd4\u7a81\u51fa\uff1b<br>\n    \u2461 <b>\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53<\/b>\uff1a\u83f2\u65af\u66fc\u58c1\u6302\u7089\u76f4\u4f9b\u751f\u6d3b\u70ed\u6c34\uff0c\u65e0\u9700\u53e6\u8d2d\u70ed\u6c34\u5668\uff1b<br>\n    \u2462 <b>\u914d\u7f6e\u52a1\u5b9e<\/b>\uff1a\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c2000\u7ea7\u7535\u5b50\u81a8\u80c0\u9600\u7cbe\u51c6\u63a7\u6e29\uff08\u00b10.5\u2103\uff09\uff0c\u53ef\u9009\u914dPE\u51c0\u5316\uff1b<br>\n    \u2463 <b>\u552e\u540e\u53ef\u9760<\/b>\uff1a\u63d0\u5347\u6cf5+\u6d6e\u5b50\u5f00\u5173\u6807\u914d\u9632\u6f0f\u6c34\uff0c\u6210\u90fd22\u5e74\u6388\u6743\u670d\u52a1\u5546\u672c\u5730\u54cd\u5e94\u3002<\/p>\n    <div class=\"lm-note\">\u26a0\ufe0f \u80fd\u8017\u65b9\u9762\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u5b9e\u9645\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002<\/div>\n  <\/div>\n  <h3>5.3 \u4e1a\u4e3b\u53cd\u9988<\/h3>\n  <div class=\"lm-box\">\n    <p>\u4e1a\u4e3b\u878d\u521b\u7396\u534e\u53f0\u00b7\u67d0\u5973\u58eb\u5b8c\u5de5\u56de\u8bbf\u8bc4\u4ef7\u5f52\u6863\u4e2d\uff08\u5f85\u6388\u6743\u540e\u8865\u5145\u771f\u5b9e\u53cd\u9988\uff09\u3002\u672c\u6848\u4f8b\u7684\u9009\u578b\u903b\u8f91\u4e0e\u5de5\u827a\u6807\u51c6\u5df2\u5b8c\u6574\u5448\u73b0\uff0c\u4f9b\u540c\u6237\u578b\u5bb6\u5ead\u53c2\u8003\u3002<\/p>\n  <\/div>\n<\/section>\n\n<!-- FAQ -->\n<section>\n  <h2>S6 \u00b7 \u5e38\u89c1\u95ee\u9898\uff08FAQ\uff09<\/h2>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u65e5\u7acb\u8212\u4eab\u65b9\u6848A\uff08\u5ba2\u9910\u538590\u578b\u5355\u5185\u673a\uff09\u4e3a\u4ec0\u4e48\u9002\u5408\u8fd9\u5957\u56db\u5ba4\uff1f\u8d85\u914d\u7387118.7%\u5e26\u5f97\u52a8\u5417\uff1f<\/div><div class=\"faq-a\">A\uff1a\u5ba2\u9910\u5385\u7ea656\u33a1\u662f\u5927\u7a7a\u95f4\uff0c\u65b9\u6848A\u7528\u5355\u53f090\u578b\uff089.0kW\uff09\u4e00\u673a\u9ad8\u6548\u8986\u76d6\uff0c\u7b80\u6d01\u53ef\u9760\uff1b\u4e3b\u536736\u3001\u6b21\u5367A22\u3001\u6b21\u5367B18\u3001\u6b21\u5367C18\u5206\u522b\u72ec\u7acb\u63a7\u6e29\u30025\u53f0\u5185\u673a\u603b\u5bb9\u91cf18.4kW\uff0c160\u4e3b\u673a\u8d85\u914d\u7387 = 18.4 \u00f7 15.5 \u2248 118.7%\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u8303\u56f4\u5185\uff0c\u65e5\u5e38\u5f002\u20133\u53f0\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u66f4\u4f18\u3001\u66f4\u5b89\u9759\uff0c\u5168\u5c4b\u591a\u5f00\u4e5f\u80fd\u5339\u914d\uff0c\u4e0d\u4f1a\u5e26\u4e0d\u52a8\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u6c1f\u673a\u4e2d\u592e\u7a7a\u8c03+\u72ec\u7acb\u83f2\u65af\u66fc\u5730\u6696\uff0c\u548c\u4e24\u8054\u4f9b\u6c34\u6a21\u5757\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/div><div class=\"faq-a\">A\uff1a\u672c\u6848\u4f8b\u662f\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u2014\u2014\u7a7a\u8c03\u7531\u65e5\u7acb\u6c1f\u673a\u70ed\u6cf5\u8d1f\u8d23\u5236\u51b7\u5236\u70ed\uff0c\u5730\u6696\u7531\u83f2\u65af\u66fc\u71c3\u6c14\u51b7\u51dd\u7089\u72ec\u7acb\u4f9b\u70ed\uff0c\u4e8c\u8005\u4e92\u4e0d\u8026\u5408\u3001\u7ef4\u62a4\u8fb9\u754c\u6e05\u6670\uff1b\u800c\u4e24\u8054\u4f9b\uff08\u6c34\u6a21\u5757\uff09\u662f\u7a7a\u8c03\u4e3b\u673a\u540c\u65f6\u4f9b\u7a7a\u8c03\u4e0e\u5730\u6696\uff08\u6c34\u7cfb\u7edf\u5171\u7528\uff09\u3002\u524d\u8005\u7cfb\u7edf\u7b80\u5355\u3001\u5404\u53f8\u5176\u804c\u3001\u6545\u969c\u4e92\u4e0d\u5f71\u54cd\uff0c\u521d\u671f\u6295\u5165\u66f4\u4f4e\u3001\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53\uff1b\u540e\u8005\u96c6\u6210\u5ea6\u9ad8\u3001\u51ac\u5b63\u8fd0\u884c\u8d39\u6709\u673a\u4f1a\u66f4\u4f4e\uff0c\u6309\u9884\u7b97\u4e0e\u8212\u9002\u504f\u597d\u9009\u62e9\u5373\u53ef\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u5ba2\u9910\u5385\u7ea656\u33a1\u4e3a\u4ec0\u4e48\u7528\u5355\u53f090\u578b\uff089.0kW\uff09\uff0c\u4e0d\u5206\u533a\uff1f<\/div><div class=\"faq-a\">A\uff1a\u5355\u53f090\u578b\u51b7\u91cf\u5145\u8db3\u3001\u4e00\u673a\u8986\u76d6\u5ba2\u9910\u5385\uff0c\u7cfb\u7edf\u7b80\u6d01\u3001\u521d\u671f\u66f4\u7701\uff1b\u82e5\u5e0c\u671b\u5ba2\u9910\u5385\u8fdb\u4e00\u6b65\u5206\u533a\u63a7\u6e29\uff08\u5982\u9910\u5385\u5355\u72ec\u4f4e\u6e29\uff09\uff0c\u53ef\u6539\u4e3a71+25\u53cc\u5185\u673a\u65b9\u6848\u3002\u672c\u6848\u9009A\u4ee5\u9884\u7b97\u53ef\u63a7\u4e0e\u70ed\u6c34\u4e00\u4f53\u4e3a\u4f18\u5148\uff0c\u5355\u53f090\u578b\u5df2\u7559\u8db3\u4f59\u91cf\uff0c\u4f53\u611f\u5747\u5300\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a160\u4e3b\u673a\u5e265\u53f0\u5185\u673a\uff08\u603b18.4kW\uff09\u8d85\u914d\u7387118.7%\u4f1a\u4e0d\u4f1a\u5e26\u4e0d\u52a8\uff1f<\/div><div class=\"faq-a\">A\uff1a\u8fde\u63a5\u7387 = 18.4 \u00f7 15.5 \u2248 118.7%\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u8303\u56f4\u5185\u3002\u65e5\u5e38\u5f002\u20133\u53f0\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u66f4\u4f18\u3001\u66f4\u5b89\u9759\uff1b\u5168\u5c4b\u591a\u5f00\u65f6160\u4e5f\u80fd\u5339\u914d\uff0c\u4e0d\u4f1a\u5e26\u4e0d\u52a8\u3002118.7%\u662f\u517c\u987e\u8282\u80fd\u4e0e\u4f59\u91cf\u7684\u7406\u60f3\u533a\u95f4\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u5730\u6696\u5730\u976299\/119\/169\u4e09\u6863\u600e\u4e48\u9009\uff1f\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e3a\u4ec0\u4e48\u63a8\u8350\uff1f<\/div><div class=\"faq-a\">A\uff1a\u4e09\u6863\u4e3a\u5730\u6696\u5730\u9762\uff08\u76d8\u7ba1+\u8f85\u6750+\u65bd\u5de5\uff09\u4e0d\u540c\u914d\u7f6e\uff1a99\u5143\/\u33a1\u7ecf\u6d4e\u578b\u3001119\u5143\/\u33a1\u5206\u63a7\u578b\uff08\u5404\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\uff09\u3001169\u5143\/\u33a1\u8282\u80fd\u8bbe\u8ba1\uff08\u52a0\u539a\u4fdd\u6e29+\u667a\u80fd\u63a7\u5236\uff09\u3002\u770b\u91cd\u6027\u4ef7\u6bd4\u4e0e\u5206\u5ba4\u63a7\u6e29\u9009119\u5206\u63a7\u578b\u3002\u70ed\u6e90\u4e0a\u83f2\u65af\u66fcB1JG 25KW\u4e3a\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u7ed3\u5408\u9884\u7b97\u4e0e\u672c\u5730\u670d\u52a1\u7f51\u70b9\u9009\u578b\u5373\u53ef\u3002<\/div><\/div>\n  <div class=\"faq\"><div class=\"faq-q\">Q\uff1a\u540e\u671f\u7ef4\u62a4\u9ebb\u70e6\u5417\uff1f\u80fd\u7528\u591a\u5c11\u5e74\uff1f\u80fd\u8017\u65b9\u9762\u600e\u6837\uff1f<\/div><div class=\"faq-a\">A\uff1a\u65e5\u7acb\u4e3b\u673a\u8bbe\u8ba1\u5bff\u547d15\u201320\u5e74\uff0c\u5ba4\u5185\u673a\u7ba1\u8def20\u5e74\u4ee5\u4e0a\uff1b\u58c1\u6302\u7089\u7ea615\u5e74\uff08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff09\u3002\u5173\u952e\u662f\u5b89\u88c5\u8d28\u91cf\u2014\u2014\u901a\u8fc7\u5206\u9636\u6bb5\u9a8c\u6536+\u4e91\u7aef\u8bb0\u5f55\u4fdd\u969c\u6bcf\u4e00\u6b65\u8fbe\u6807\u3002\u80fd\u8017\u65b9\u9762\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u5b9e\u9645\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002\u9f99\u8109\u5728\u6210\u90fd\u672c\u5730\u8fd0\u842522\u5e74\uff0c\u81ea\u6709\u552e\u540e\u56e2\u961f\uff0c\u54cd\u5e94\u53ca\u65f6\u3002<\/div><\/div>\n<\/section>\n\n<!-- \u5185\u94fe -->\n<section>\n  <h2>S7 \u00b7 \u540c\u7247\u533a\u6848\u4f8b\u4e0e\u65b9\u6848\u5e93<\/h2>\n  <div class=\"lm-links\">\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><div class=\"t\">\u9f99\u8109\u6696\u901a\u5b8c\u5de5\u6848\u4f8b\u5e93<\/div><div class=\"d\">\u6210\u90fd\u5168\u57df\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e0e\u5730\u6696\u5b9e\u666f\u6848\u4f8b\u805a\u5408<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=5849\" target=\"_blank\"><div class=\"t\">\u6696\u901a\u65b9\u6848\u5e93<\/div><div class=\"d\">\u5e73\u5c42\/\u522b\u5885\u591a\u7cfb\u7edf\u914d\u7f6e\u4e0e\u900f\u660e\u62a5\u4ef7\u53c2\u8003<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\"><div class=\"t\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4e13\u9898<\/div><div class=\"d\">\u8212\u4eab\/\u5168\u6548\/\u6f8e\u6e43\u52a8\u529b\u7cfb\u5217\u9009\u578b\u6307\u5357<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=3147\" target=\"_blank\"><div class=\"t\">\u58c1\u6302\u7089\u5730\u6696\u4e13\u9898<\/div><div class=\"d\">\u83f2\u65af\u66fc\/\u535a\u4e16\u51b7\u51dd\u7089\u4e0e\u5730\u6696\u5730\u9762\u4e09\u6863<\/div><\/a>\n    <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\"><div class=\"t\">\u514d\u8d39\u52d8\u6d4b\u9884\u7ea6<\/div><div class=\"d\">\u6210\u90fd22\u5e74\u6388\u6743\u670d\u52a1\u5546\u4e0a\u95e8\u8d1f\u8377\u6d4b\u7b97<\/div><\/a>\n  <\/div>\n<\/section>\n\n<!-- CTA -->\n<div class=\"cta\">\n  <h3>\ud83d\udcde \u540c\u6237\u578b\u65b9\u6848\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h3>\n  <p>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546\uff0c\u6210\u90fd\u672c\u5730\u8fd0\u842522\u5e74\uff0c\u81ea\u6709\u552e\u540e\u56e2\u961f\u3002<\/p>\n  <p>\u95e8\u5e97\uff1a\u2460 \u6210\u90fd\u9f99\u8109\u6696\u901a\u65d7\u8230\u5e97\u3000\u2461 \u9f99\u8109\u6696\u901a\u7279\u7ea6\u5b89\u88c5\u670d\u52a1\u4e2d\u5fc3<\/p>\n  <p>\u5ea7\u673a\uff1a<a href=\"tel:02861649321\">028-61649321<\/a>\u3000\u987e\u95ee\uff1a\u5f90\u65b0\u5e73 <a href=\"tel:18227055065\">182-2705-5065<\/a><\/p>\n  <p>\u670d\u52a1\u8303\u56f4\uff1a\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u4e0e\u6237\u578b\u65b9\u6848\u51fa\u5177\u3002<\/p>\n<\/div>\n\n<footer>\u00a9 \u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u65e5\u7acb\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u672c\u6848\u4f8b\u542b\u540c\u6807\u51c6\u5de5\u827a\u793a\u610f\uff0c\u5177\u4f53\u4ee5\u5b8c\u5de5\u5b9e\u6d4b\u4e3a\u51c6<\/footer>\n<\/div>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a\",\n  \"description\": \"\u9f99\u8109\u6696\u901a\u843d\u5730\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u4e1a\u4e3b\u9009\u5b9a\u65e5\u7acb\u8212\u4eab\u65b9\u6848A\uff08RAS-160\u4e3b\u673a+5\u53f0\u5185\u673a\u00b7\u8d85\u914d\u7387118.7%\uff09\u642d\u914d\u83f2\u65af\u66fcB1JG 25KW\u51b7\u51dd\u7089\u72ec\u7acb\u5730\u6696\uff08119\u5143\/\u33a1\u5206\u63a7\u578b\uff09\uff1a\u6c1f\u673a\u7a7a\u8c03\u67d4\u98ce\u4e0d\u71e5\u3001\u5ba2\u9910\u538590\u578b\u5355\u5185\u673a\u9ad8\u6548\u8986\u76d6\uff0c\u5730\u6696\u8db3\u5e95\u6e29\u6696\uff1b\u4e25\u683c\u6309GB50736\u4e0eJGJ142\u53cc\u56fd\u6807\u9a8c\u6536\uff0c\u6210\u90fd22\u5e74\u65e5\u7acb\u6388\u6743\u670d\u52a1\u5546\u514d\u8d39\u52d8\u6d4b\u3002\",\n  \"keywords\": \"\u9f99\u8109\u6696\u901a,\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03,\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696,\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0,114\u33a1\u56db\u5ba4\u6696\u901a\u6848\u4f8b,\u58c1\u6302\u7089\u5730\u6696,\u6210\u90fd\u65e5\u7acb\u6388\u6743,\u53cc\u7cfb\u7edf,\u900f\u660e\u914d\u7f6e\",\n  \"author\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\u9f99\u8109\u6696\u901a\",\n    \"logo\": {\n      \"@type\": \"ImageObject\",\n      \"url\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-logo.png\"\n    }\n  },\n  \"about\": {\n    \"@type\": \"Thing\",\n    \"name\": \"\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03 + \u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696 \u56db\u5ba4\u4e24\u5385\u5b8c\u5de5\u6848\u4f8b\"\n  },\n  \"articleSection\": \"\u6696\u901a\u6848\u4f8b\u5206\u4eab\"\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u65e5\u7acb\u8212\u4eab\u65b9\u6848A\uff08\u5ba2\u9910\u538590\u578b\u5355\u5185\u673a\uff09\u4e3a\u4ec0\u4e48\u9002\u5408\u8fd9\u5957\u56db\u5ba4\uff1f\u8d85\u914d\u7387118.7%\u5e26\u5f97\u52a8\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5ba2\u9910\u5385\u7ea656\u33a1\u662f\u5927\u7a7a\u95f4\uff0c\u65b9\u6848A\u7528\u5355\u53f090\u578b\uff089.0kW\uff09\u4e00\u673a\u9ad8\u6548\u8986\u76d6\uff0c\u7b80\u6d01\u53ef\u9760\uff1b\u4e3b\u536736\u3001\u6b21\u5367A22\u3001\u6b21\u5367B18\u3001\u6b21\u5367C18\u5206\u522b\u72ec\u7acb\u63a7\u6e29\u30025\u53f0\u5185\u673a\u603b\u5bb9\u91cf18.4kW\uff0c160\u4e3b\u673a\u8d85\u914d\u7387 = 18.4 \u00f7 15.5 \u2248 118.7%\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u8303\u56f4\u5185\uff0c\u65e5\u5e38\u5f002\u20133\u53f0\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u66f4\u4f18\u3001\u66f4\u5b89\u9759\uff0c\u5168\u5c4b\u591a\u5f00\u4e5f\u80fd\u5339\u914d\uff0c\u4e0d\u4f1a\u5e26\u4e0d\u52a8\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6c1f\u673a\u4e2d\u592e\u7a7a\u8c03+\u72ec\u7acb\u83f2\u65af\u66fc\u5730\u6696\uff0c\u548c\u4e24\u8054\u4f9b\u6c34\u6a21\u5757\u6709\u4ec0\u4e48\u533a\u522b\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u672c\u6848\u4f8b\u662f\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\u2014\u2014\u7a7a\u8c03\u7531\u65e5\u7acb\u6c1f\u673a\u70ed\u6cf5\u8d1f\u8d23\u5236\u51b7\u5236\u70ed\uff0c\u5730\u6696\u7531\u83f2\u65af\u66fc\u71c3\u6c14\u51b7\u51dd\u7089\u72ec\u7acb\u4f9b\u70ed\uff0c\u4e8c\u8005\u4e92\u4e0d\u8026\u5408\u3001\u7ef4\u62a4\u8fb9\u754c\u6e05\u6670\uff1b\u800c\u4e24\u8054\u4f9b\uff08\u6c34\u6a21\u5757\uff09\u662f\u7a7a\u8c03\u4e3b\u673a\u540c\u65f6\u4f9b\u7a7a\u8c03\u4e0e\u5730\u6696\uff08\u6c34\u7cfb\u7edf\u5171\u7528\uff09\u3002\u524d\u8005\u7cfb\u7edf\u7b80\u5355\u3001\u5404\u53f8\u5176\u804c\u3001\u6545\u969c\u4e92\u4e0d\u5f71\u54cd\uff0c\u521d\u671f\u6295\u5165\u66f4\u4f4e\u3001\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53\uff1b\u540e\u8005\u96c6\u6210\u5ea6\u9ad8\u3001\u51ac\u5b63\u8fd0\u884c\u8d39\u6709\u673a\u4f1a\u66f4\u4f4e\uff0c\u6309\u9884\u7b97\u4e0e\u8212\u9002\u504f\u597d\u9009\u62e9\u5373\u53ef\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5ba2\u9910\u5385\u7ea656\u33a1\u4e3a\u4ec0\u4e48\u7528\u5355\u53f090\u578b\uff089.0kW\uff09\uff0c\u4e0d\u5206\u533a\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5355\u53f090\u578b\u51b7\u91cf\u5145\u8db3\u3001\u4e00\u673a\u8986\u76d6\u5ba2\u9910\u5385\uff0c\u7cfb\u7edf\u7b80\u6d01\u3001\u521d\u671f\u66f4\u7701\uff1b\u82e5\u5e0c\u671b\u5ba2\u9910\u5385\u8fdb\u4e00\u6b65\u5206\u533a\u63a7\u6e29\uff08\u5982\u9910\u5385\u5355\u72ec\u4f4e\u6e29\uff09\uff0c\u53ef\u6539\u4e3a71+25\u53cc\u5185\u673a\u65b9\u6848\u3002\u672c\u6848\u9009A\u4ee5\u9884\u7b97\u53ef\u63a7\u4e0e\u70ed\u6c34\u4e00\u4f53\u4e3a\u4f18\u5148\uff0c\u5355\u53f090\u578b\u5df2\u7559\u8db3\u4f59\u91cf\uff0c\u4f53\u611f\u5747\u5300\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"160\u4e3b\u673a\u5e265\u53f0\u5185\u673a\uff08\u603b18.4kW\uff09\u8d85\u914d\u7387118.7%\u4f1a\u4e0d\u4f1a\u5e26\u4e0d\u52a8\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u8fde\u63a5\u7387 = 18.4 \u00f7 15.5 \u2248 118.7%\uff0c\u5728\u65e5\u7acb\u5141\u8bb8\u2264130%\u8303\u56f4\u5185\u3002\u65e5\u5e38\u5f002\u20133\u53f0\u90e8\u5206\u8d1f\u8377\u80fd\u6548\u66f4\u4f18\u3001\u66f4\u5b89\u9759\uff1b\u5168\u5c4b\u591a\u5f00\u65f6160\u4e5f\u80fd\u5339\u914d\uff0c\u4e0d\u4f1a\u5e26\u4e0d\u52a8\u3002118.7%\u662f\u517c\u987e\u8282\u80fd\u4e0e\u4f59\u91cf\u7684\u7406\u60f3\u533a\u95f4\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5730\u6696\u5730\u976299\/119\/169\u4e09\u6863\u600e\u4e48\u9009\uff1f\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e3a\u4ec0\u4e48\u63a8\u8350\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e09\u6863\u4e3a\u5730\u6696\u5730\u9762\uff08\u76d8\u7ba1+\u8f85\u6750+\u65bd\u5de5\uff09\u4e0d\u540c\u914d\u7f6e\uff1a99\u5143\/\u33a1\u7ecf\u6d4e\u578b\u3001119\u5143\/\u33a1\u5206\u63a7\u578b\uff08\u5404\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\uff09\u3001169\u5143\/\u33a1\u8282\u80fd\u8bbe\u8ba1\uff08\u52a0\u539a\u4fdd\u6e29+\u667a\u80fd\u63a7\u5236\uff09\u3002\u770b\u91cd\u6027\u4ef7\u6bd4\u4e0e\u5206\u5ba4\u63a7\u6e29\u9009119\u5206\u63a7\u578b\u3002\u70ed\u6e90\u4e0a\u83f2\u65af\u66fcB1JG 25KW\u4e3a\u5fb7\u7cfb\u51b7\u51dd\u7089\uff0c\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u7ed3\u5408\u9884\u7b97\u4e0e\u672c\u5730\u670d\u52a1\u7f51\u70b9\u9009\u578b\u5373\u53ef\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u540e\u671f\u7ef4\u62a4\u9ebb\u70e6\u5417\uff1f\u80fd\u7528\u591a\u5c11\u5e74\uff1f\u80fd\u8017\u65b9\u9762\u600e\u6837\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u65e5\u7acb\u4e3b\u673a\u8bbe\u8ba1\u5bff\u547d15\u201320\u5e74\uff0c\u5ba4\u5185\u673a\u7ba1\u8def20\u5e74\u4ee5\u4e0a\uff1b\u58c1\u6302\u7089\u7ea615\u5e74\uff08\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u70ed\u6548\u7387\u9ad8\u4e8e\u5e38\u89c4\u58c1\u6302\u7089\uff0c\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff09\u3002\u5173\u952e\u662f\u5b89\u88c5\u8d28\u91cf\u2014\u2014\u901a\u8fc7\u5206\u9636\u6bb5\u9a8c\u6536+\u4e91\u7aef\u8bb0\u5f55\u4fdd\u969c\u6bcf\u4e00\u6b65\u8fbe\u6807\u3002\u80fd\u8017\u65b9\u9762\uff0c\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u4e0b\u6709\u673a\u4f1a\u964d\u4f4e\u71c3\u6c14\u6d88\u8017\uff0c\u5b9e\u9645\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u4ef7\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\u3002\u9f99\u8109\u5728\u6210\u90fd\u672c\u5730\u8fd0\u842522\u5e74\uff0c\u81ea\u6709\u552e\u540e\u56e2\u961f\uff0c\u54cd\u5e94\u53ca\u65f6\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"\u9f99\u8109\u6696\u901a\",\n      \"item\": \"https:\/\/longmai-nt.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"\u6848\u4f8b\u5206\u4eab\",\n      \"item\": \"https:\/\/longmai-nt.com\/?page_id=2297\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0\u56db\u5ba4\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\",\n      \"item\": \"https:\/\/longmai-nt.com\/?page_id=2297\"\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"LocalBusiness\",\n  \"name\": \"\u9f99\u8109\u6696\u901a\",\n  \"description\": \"\u6210\u90fd\u65e5\u7acb\u5b98\u65b9\u6388\u6743\u6696\u901a\u670d\u52a1\u5546\uff0c22\u5e74\u672c\u5730\u8fd0\u8425\uff0c\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03\u4e0e\u58c1\u6302\u7089\u5730\u6696\u8bbe\u8ba1\u65bd\u5de5\u4e0e\u552e\u540e\u3002\",\n  \"telephone\": \"028-61649321\",\n  \"address\": {\n    \"@type\": \"PostalAddress\",\n    \"addressRegion\": \"\u6210\u90fd\",\n    \"addressCountry\": \"CN\"\n  },\n  \"areaServed\": \"\u6210\u90fd\",\n  \"url\": \"https:\/\/longmai-nt.com\"\n}\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u203a \u6848\u4f8b\u5206\u4eab \u203a \u6210\u534e\u533a\u878d\u521b\u7396 [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":2297,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-11822","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u67d0\u5973\u58eb\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u65b9\u6848A\uff0c\u5ba2\u9910\u538590\u578b\u5355\u5927\u5185\u673a\uff0c\u642d\u914d\u83f2\u65af\u66fc25KW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u5206\u63a7\u578b119\u5143\/\u33a1\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u6210\u90fd\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=11822\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u67d0\u5973\u58eb\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u65b9\u6848A\uff0c\u5ba2\u9910\u538590\u578b\u5355\u5927\u5185\u673a\uff0c\u642d\u914d\u83f2\u65af\u66fc25KW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u5206\u63a7\u578b119\u5143\/\u33a1\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u6210\u90fd\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=11822\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-28T08:27:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822\",\"name\":\"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tfgywlc-lls-azzs.jpg\",\"datePublished\":\"2026-08-29T05:15:42+00:00\",\"dateModified\":\"2026-10-28T08:27:08+00:00\",\"description\":\"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u67d0\u5973\u58eb\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u65b9\u6848A\uff0c\u5ba2\u9910\u538590\u578b\u5355\u5927\u5185\u673a\uff0c\u642d\u914d\u83f2\u65af\u66fc25KW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u5206\u63a7\u578b119\u5143\\\/\u33a1\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u6210\u90fd\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tfgywlc-lls-azzs.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tfgywlc-lls-azzs.jpg\",\"width\":1080,\"height\":1440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11822#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2297\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u67d0\u5973\u58eb\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u65b9\u6848A\uff0c\u5ba2\u9910\u538590\u578b\u5355\u5927\u5185\u673a\uff0c\u642d\u914d\u83f2\u65af\u66fc25KW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u5206\u63a7\u578b119\u5143\/\u33a1\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u6210\u90fd\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=11822","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u67d0\u5973\u58eb\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u65b9\u6848A\uff0c\u5ba2\u9910\u538590\u578b\u5355\u5927\u5185\u673a\uff0c\u642d\u914d\u83f2\u65af\u66fc25KW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u5206\u63a7\u578b119\u5143\/\u33a1\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u6210\u90fd\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=11822","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-28T08:27:08+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=11822","url":"https:\/\/longmai-nt.com\/?page_id=11822","name":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=11822#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=11822#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","datePublished":"2026-08-29T05:15:42+00:00","dateModified":"2026-10-28T08:27:08+00:00","description":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff0c\u67d0\u5973\u58eb\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u65b9\u6848A\uff0c\u5ba2\u9910\u538590\u578b\u5355\u5927\u5185\u673a\uff0c\u642d\u914d\u83f2\u65af\u66fc25KW\u51b7\u51dd\u7089\u5730\u6696\uff0c\u5206\u63a7\u578b119\u5143\/\u33a1\uff0c\u65e5\u7acb\u5b98\u65b9\u6388\u6743\uff0c\u6210\u90fd\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=11822#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=11822"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=11822#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs.jpg","width":1080,"height":1440},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=11822#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3","item":"https:\/\/longmai-nt.com\/?page_id=2297"},{"@type":"ListItem","position":3,"name":"\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b-\u9f99\u8109\u6696\u901a"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11822"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11822\/revisions"}],"predecessor-version":[{"id":11823,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11822\/revisions\/11823"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2297"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}