{"id":11894,"date":"2026-08-30T22:21:21","date_gmt":"2026-08-30T14:21:21","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=11894"},"modified":"2026-10-27T01:23:21","modified_gmt":"2026-10-26T17:23:21","slug":"%e6%9a%97%e5%9f%8b%e6%9a%96%e6%b0%94%e7%89%87%e5%a6%82%e4%bd%95%e8%ae%be%e8%ae%a1%e6%89%8d%e8%88%92%e9%80%82%e7%a8%b3%e5%ae%9a%e8%8a%82%e8%83%bd%ef%bc%88%e6%88%90%e9%83%bd-%ef%bc%89%e5%9b%9b%e8%a6%81","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=11894","title":{"rendered":"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303"},"content":{"rendered":"<style>\n:root{\n  --lm-red:#c0392b; --lm-red-lt:#fdf1ee; --lm-ink:#222; --lm-sub:#5a5a5a;\n  --lm-line:#e6e6e6; --lm-bg:#fff; --lm-soft:#fafafa; --lm-blue:#f4f8fd;\n}\nhtml{scroll-behavior:smooth}\nbody{\n  font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",\"Helvetica Neue\",Arial,sans-serif;\n  color:var(--lm-ink); background:var(--lm-bg); line-height:1.85; margin:0;\n  font-size:16px; -webkit-font-smoothing:antialiased;\n}\n.lm-wrap{max-width:960px;margin:0 auto;padding:0 18px 60px}\nh1{font-size:1.72rem;line-height:1.45;margin:26px 0 10px;color:#1a1a1a;letter-spacing:.3px}\nh2{font-size:1.3rem;margin:44px 0 14px;padding:10px 0 10px 12px;border-left:5px solid var(--lm-red);\n   background:linear-gradient(90deg,var(--lm-red-lt),transparent);scroll-margin-top:24px;border-radius:0 6px 6px 0}\nh3{font-size:1.08rem;margin:26px 0 10px;color:#2b2b2b;padding-left:9px;border-left:3px solid #e8b4aa}\nh4{font-size:1rem;margin:18px 0 8px;color:#333}\np{margin:10px 0}\nul,ol{margin:10px 0;padding-left:22px}\nli{margin:6px 0}\ntable{border-collapse:collapse;width:100%;margin:14px 0;font-size:.92rem;background:#fff}\nth,td{border:1px solid var(--lm-line);padding:9px 11px;text-align:left;vertical-align:top}\nth{background:#f3f4f6;font-weight:700;color:#333}\ntbody tr:nth-child(even){background:var(--lm-soft)}\n.lm-intro{background:var(--lm-blue);border:1px solid #d8e6f5;border-radius:10px;padding:14px 16px;margin:16px 0;font-size:.95rem}\n.lm-notice{background:var(--lm-red-lt);border:1px solid #f0c9bf;border-left:4px solid var(--lm-red);\n  border-radius:8px;padding:12px 15px;margin:16px 0;font-size:.94rem}\n.spec-box{border:1px solid #f0d9b5;background:#fffdf6;border-left:4px solid #e0a800;\n  border-radius:8px;padding:14px 16px;margin:16px 0}\n.spec-box h3{margin-top:0;border-left:none;padding-left:0;color:#8a6100}\n.warn-box{border:1px solid #f2c4c0;background:#fff7f6;border-left:4px solid var(--lm-red);\n  border-radius:8px;padding:14px 16px;margin:16px 0}\n.formula{background:#f6f6f8;border:1px dashed #c8c8cf;border-radius:8px;padding:12px 14px;margin:12px 0;\n  font-family:Consolas,\"Courier New\",monospace;font-size:.92rem;line-height:1.9}\n.toc{background:var(--lm-soft);border:1px solid var(--lm-line);border-radius:10px;padding:14px 18px;margin:18px 0}\n.toc a{color:#2c3e50;text-decoration:none;font-size:.94rem}\n.toc a:hover{color:var(--lm-red);text-decoration:underline}\n.toc ol{margin:6px 0;padding-left:20px}\n.card-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:12px;margin:14px 0}\n.card{border:1px solid var(--lm-line);border-radius:10px;padding:12px 14px;background:#fff}\n.card .k{font-size:.8rem;color:var(--lm-sub);letter-spacing:.5px}\n.card .v{font-size:1.22rem;font-weight:700;color:var(--lm-red);line-height:1.5}\n.card .d{font-size:.83rem;color:var(--lm-sub);margin-top:3px}\n.fig-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:14px;margin:16px 0}\nfigure{margin:0;border:1px solid var(--lm-line);border-radius:10px;overflow:hidden;background:#fff}\nfigure img{width:100%;display:block;background:#f2f2f4}\nfigcaption{font-size:.82rem;color:var(--lm-sub);padding:8px 10px;border-top:1px solid var(--lm-line);background:var(--lm-soft)}\n.step-item{border:1px solid var(--lm-line);border-radius:10px;padding:14px 16px;margin:12px 0;background:#fff}\n.step-item h3{margin-top:0}\n.chk{background:#f2f9f4;border-left:4px solid #2e9e5b;border-radius:6px;padding:9px 13px;margin:9px 0;font-size:.93rem}\n.faq-item{border:1px solid var(--lm-line);border-radius:10px;margin:10px 0;overflow:hidden}\n.faq-item h3{margin:0;padding:12px 15px;background:var(--lm-soft);font-size:1rem;border-left:none}\n.faq-ans{padding:10px 15px;font-size:.94rem}\n.link-card{display:block;border:1px solid var(--lm-line);border-radius:10px;padding:11px 14px;margin:9px 0;\n  text-decoration:none;background:#fff;transition:border-color .2s}\n.link-card:hover{border-color:var(--lm-red)}\n.link-card .title{display:block;font-weight:700;color:#1f4f8b;font-size:.98rem}\n.link-card .desc{display:block;color:var(--lm-sub);font-size:.85rem;margin-top:2px}\n.cta-box{background:#fff8f6;border:1px solid #f0c9bf;border-radius:12px;padding:18px 20px;margin:22px 0 !important}\n.cta-box h3{margin:0 0 6px !important;border-left:none !important;padding-left:0 !important}\n.btn{display:inline-block;background:#c0392b !important;color:#fff !important;padding:9px 20px;border-radius:8px;\n  text-decoration:none;margin-top:8px;font-size:.95rem}\n.tiny{font-size:.82rem;color:#777}\n@media(max-width:640px){\n  h1{font-size:1.35rem}\n  h2{font-size:1.12rem}\n  table{font-size:.85rem}\n  th,td{padding:7px 8px}\n}\n<\/style>\n<div class=\"lm-wrap\">\n<p><!-- ===================== HERO ===================== --><\/p>\n<h2 id=\"top\">\u6697\u57cb\u6696\u6c14\u7247\u8bbe\u8ba1\u89c4\u8303\uff08\u6210\u90fd\uff09<br \/>\u56db\u8981\u7d20\u8bbe\u8ba1\u6807\u51c6 + \u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u5b9a<\/h2>\n<p>\u672c\u300a\u6697\u57cb\u6696\u6c14\u7247\u8bbe\u8ba1\u89c4\u8303 V2.0\u300b\u4e13\u4e3a<strong>\u6210\u90fd\u6bdb\u576f\u65b0\u623f\u3001\u5168\u5c4b\u7ffb\u65b0<\/strong>\u51c6\u5907\uff0c\u9488\u5bf9\u6210\u90fd\u4f4f\u5b85\u4fdd\u6e29\u666e\u904d\u504f\u5f31\u3001\u51ac\u5b63\u6e7f\u51b7\u7684\u7279\u70b9\uff0c\u660e\u786e\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668\u6697\u57cb\u6696\u6c14\u7247\u7684<strong>\u56db\u8981\u7d20\u8bbe\u8ba1\u6807\u51c6\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u5b9a\u6807\u51c6<\/strong>\uff0c\u53ef\u4f9b\u4e1a\u4e3b\u3001\u5ba4\u5185\u8bbe\u8ba1\u5e08\u3001\u65bd\u5de5\u56e2\u961f\u7528\u4e8e\u8bbe\u8ba1\u4ea4\u5e95\u4e0e\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u3002\u672c\u9875\u7531\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\u6280\u672f\u51fa\u54c1\uff0c\u9002\u7528\u8303\u56f4\u8986\u76d6\u6210\u90fd\u9ad8\u65b0\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u9a7f\u3001\u5929\u5e9c\u65b0\u533a\u3001\u9752\u7f8a\u3001\u6210\u534e\u3001\u89c6\u9ad8\u7b49\u533a\u57df\u3002<\/p>\n<div class=\"lm-intro\">\n<p style=\"margin:0 0 6px\"><strong>\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u8bbe\u8ba1\u4e0e\u65bd\u5de5\u6267\u884c\u6807\u51c6<\/strong>\u3000\u7248\u672c V2.0\u3000\u4fee\u8ba2\u65e5\u671f 2026-08-30<\/p>\n<p style=\"margin:0\">\u9002\u7528\u8303\u56f4\uff1a\u6210\u90fd\u5730\u533a\u65b0\u623f\u88c5\u4fee \/ \u8001\u623f\u91cd\u88c5\uff0c\u91c7\u7528<strong>\u6697\u57cb\u6696\u6c14\u7247\uff08\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668\u5e03\u7ba1\uff09<\/strong>\u7684\u4f4f\u5b85\u9879\u76ee\u3002\u672c\u89c4\u8303\u9762\u5411\u4e1a\u4e3b\u3001\u8bbe\u8ba1\u5e08\u4e0e\u65bd\u5de5\u961f\u4e09\u65b9\uff0c\u65e2\u662f\u8bbe\u8ba1\u4ea4\u5e95\u4f9d\u636e\uff0c\u4e5f\u662f\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u4f9d\u636e\u3002\u672c\u9875\u5de5\u5730\u5b9e\u62cd\u5747\u6765\u81ea<strong>\u6210\u90fd\u5e02\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce \u00b7 \u5f20\u8001\u5e08<\/strong>\u5728\u5efa\u5de5\u5730\uff0c\u4e1a\u4e3b\u4fe1\u606f\u5df2\u6309\u8981\u6c42\u8131\u654f\uff08\u4ec5\u7559\u59d3\u6c0f\uff09\u3002<\/p>\n<\/div>\n<div class=\"lm-notice\">\n<strong>\u672c\u7248\uff08V2.0\uff09\u76f8\u5bf9\u4e0a\u4e00\u7248\u7684\u5173\u952e\u4fee\u8ba2\uff0c\u5171 4 \u6761\uff0c\u8bbe\u8ba1\u4e0e\u62a5\u4ef7\u73af\u8282\u5fc5\u987b\u540c\u6b65\u6267\u884c\uff1a<\/strong><\/p>\n<ol style=\"margin:8px 0 0\">\n<li><strong>\u58c1\u6302\u7089\u5224\u5e9f\u5e74\u9650\u7edf\u4e00\u4e3a 8 \u5e74<\/strong>\u2014\u2014\u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089\u6267\u884c\u540c\u4e00\u56fd\u5bb6\u62a5\u5e9f\u8981\u6c42\uff0c\u6b64\u524d\"\u51b7\u51dd\u7089 10-15 \u5e74\"\u7684\u8868\u8ff0\u4f5c\u5e9f\u3002<\/li>\n<li><strong>\u65b0\u589e\u5185\u7f6e\u6c34\u6cf5\u70ed\u503c\u6838\u7b97<\/strong>\u2014\u2014\u58c1\u6302\u7089\u5185\u7f6e\u5faa\u73af\u6cf5\u6d41\u91cf\u7ea6 800 L\/h\uff0c\u9ad8\u6e29\u5de5\u51b5\uff08\u0394t=20\u2103\uff09\u7ea6\u643a\u5e26 16 kW \u70ed\u503c\uff0c\u4f4e\u6e29\u5de5\u51b5\uff08\u0394t=10\u2103\uff09\u4ec5\u7ea6 8 kW\uff1b\u8d85\u51fa\u5373<strong>\u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/strong>\u3002<\/li>\n<li><strong>\u65b0\u589e\u5b9a\u9891\u7089\u4e0e\u53d8\u6d41\u91cf\u517c\u5bb9\u5224\u5b9a<\/strong>\u2014\u2014\u666e\u901a\u7089\u4e3a\u5b9a\u9891\u7cfb\u7edf\uff0c\u4e0d\u5f97\u76f4\u63a5\u914d\u81ea\u52a8\u6e29\u5305\u7c7b\u53d8\u6d41\u91cf\u672b\u7aef\uff1b\u9700\u53d8\u6d41\u91cf\u63a7\u5236\u65f6\uff0c\u901a\u8fc7\u4e8c\u6b21\u7cfb\u7edf + \u53d8\u9891\u4e8c\u6b21\u6cf5\u5b9e\u73b0\u3002<\/li>\n<li><strong>\u65b0\u589e\u6696\u6c14\u7247\u63a7\u5236\u65b9\u5f0f\u6761\u6b3e<\/strong>\u2014\u2014\u6697\u57cb\u7cfb\u7edf\u4e0d\u518d\u4ee5\u624b\u52a8\u9600\u4e3a\u4e3b\u63a7\u624b\u6bb5\uff0c\u4f18\u5148\u91c7\u7528\u623f\u95f4\u6e29\u63a7\u5668 + \u5206\u96c6\u6c34\u5668\u7535\u70ed\u6267\u884c\u5668\u3002<\/li>\n<\/ol>\n<\/div>\n<p><!-- ===================== \u76ee\u5f55 ===================== --><\/p>\n<div class=\"toc\">\n<strong>\u76ee\u5f55<\/strong><\/p>\n<ol>\n<li><a href=\"#overview\">\u89c4\u8303\u603b\u89c8\uff1a\u56db\u8981\u7d20 + \u4e09\u6761\u786c\u5224\u636e<\/a><\/li>\n<li><a href=\"#s1\">\u7b2c\u4e00\u8981\u7d20 \u00b7 \u70ed\u6e90\uff1a\u4ea7\u70ed\u8981\u51c6\uff08\u542b\u5224\u5e9f\u5e74\u9650\u4e0e\u5185\u7f6e\u6cf5\u6838\u7b97\uff09<\/a><\/li>\n<li><a href=\"#s2\">\u7b2c\u4e8c\u8981\u7d20 \u00b7 \u8f93\u914d\uff1a\u8fd0\u70ed\u8981\u901a\uff08\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\u5b9e\u62cd\uff09<\/a><\/li>\n<li><a href=\"#s3\">\u7b2c\u4e09\u8981\u7d20 \u00b7 \u672b\u7aef\uff1a\u6563\u70ed\u8981\u591f\uff08\u6696\u6c14\u7247\u9884\u7559\u5b9e\u62cd\uff09<\/a><\/li>\n<li><a href=\"#s4\">\u7b2c\u56db\u8981\u7d20 \u00b7 \u63a7\u5236\uff1a\u4f9b\u70ed\u6309\u9700\uff08\u5b9a\u9891 \/ \u53d8\u6d41\u91cf \/ \u6e29\u63a7\u5668\uff09<\/a><\/li>\n<li><a href=\"#s5\">\u4e8c\u6b21\u7cfb\u7edf\u4e13\u7ae0\uff1a4 \u6761\u5f3a\u5236\u5224\u636e\u4e0e\u6807\u51c6\u914d\u7f6e<\/a><\/li>\n<li><a href=\"#s6\">\u8bbe\u8ba1\u516b\u6b65\u6cd5\u4e0e\u9a8c\u6536\u6e05\u5355\uff08\u53ef\u9010\u9879\u6253\u52fe\uff09<\/a><\/li>\n<li><a href=\"#s7\">\u8bbe\u8ba1\u89c4\u8303\u901f\u67e5\u603b\u8868<\/a><\/li>\n<li><a href=\"#faq\">\u5e38\u89c1\u95ee\u9898 FAQ<\/a><\/li>\n<\/ol>\n<\/div>\n<p><!-- ===================== \u00a70 \u603b\u89c8 ===================== --><\/p>\n<h2 id=\"overview\">\u4e00\u3001\u89c4\u8303\u603b\u89c8\uff1a\u56db\u8981\u7d20 + \u4e09\u6761\u786c\u5224\u636e<\/h2>\n<p>\u6697\u57cb\u6696\u6c14\u7247\u662f<strong>\u6c34\u7cfb\u7edf<\/strong>\u2014\u2014\u70ed\u6c34\u4ece\u58c1\u6302\u7089\u4ea7\u51fa\uff0c\u7ecf\u7ba1\u9053\u9001\u5230\u5404\u7ec4\u6696\u6c14\u7247\uff0c\u6563\u70ed\u540e\u56de\u6d41\u518d\u52a0\u70ed\u3002\u8fd9\u6761\u94fe\u8def\u4e0a<strong>\u4ea7\u70ed\u3001\u8fd0\u70ed\u3001\u6563\u70ed\u3001\u63a7\u70ed<\/strong>\u56db\u4e2a\u73af\u8282\u4efb\u610f\u4e00\u4e2a\u6ca1\u8bbe\u8ba1\u597d\uff0c\u90fd\u4f1a\u8868\u73b0\u4e3a\"\u5f00\u4e86\u534a\u5929\u4e0d\u70ed\"\"\u8fd1\u7aef\u70ed\u5f97\u5f00\u7a97\u3001\u8fdc\u7aef\u51b7\"\"\u6c14\u8d39\u82b1\u4e86\u6548\u679c\u4e00\u822c\"\uff0c\u800c\u7ba1\u8def\u4e00\u65e6\u57cb\u8fdb\u5730\u9762\uff0c\u8fd4\u5de5\u6210\u672c\u6781\u9ad8\u3002<\/p>\n<div class=\"card-grid\">\n<div class=\"card\">\n<div class=\"k\">\u7b2c\u4e00\u8981\u7d20 \u00b7 \u70ed\u6e90<\/div>\n<div class=\"v\">\u4ea7\u70ed\u8981\u51c6<\/div>\n<div class=\"d\">\u7089\u578b\u3001\u529f\u7387\u3001\u5224\u5e9f\u5e74\u9650\u3001\u5185\u7f6e\u6cf5\u70ed\u503c<\/div>\n<\/div>\n<div class=\"card\">\n<div class=\"k\">\u7b2c\u4e8c\u8981\u7d20 \u00b7 \u8f93\u914d<\/div>\n<div class=\"v\">\u8fd0\u70ed\u8981\u901a<\/div>\n<div class=\"d\">\u7ae0\u9c7c\u5f0f\u3001\u4e3b\u7ba1\u7ba1\u5f84\u3001\u5927\u5f27\u5f2f\u3001\u7edd\u6c27\u3001\u65e0\u63a5\u5934<\/div>\n<\/div>\n<div class=\"card\">\n<div class=\"k\">\u7b2c\u4e09\u8981\u7d20 \u00b7 \u672b\u7aef<\/div>\n<div class=\"v\">\u6563\u70ed\u8981\u591f<\/div>\n<div class=\"d\">\u7247\u6570\u3001\u5b89\u88c5\u4f4d\u7f6e\u3001\u6750\u8d28\u3001\u9884\u7559\u7ba1\u8def\u5e03\u5c40<\/div>\n<\/div>\n<div class=\"card\">\n<div class=\"k\">\u7b2c\u56db\u8981\u7d20 \u00b7 \u63a7\u5236<\/div>\n<div class=\"v\">\u4f9b\u70ed\u6309\u9700<\/div>\n<div class=\"d\">\u6e29\u63a7\u5668\u3001\u6267\u884c\u5668\u3001\u8054\u52a8\u3001\u53d8\u6d41\u91cf\u517c\u5bb9<\/div>\n<\/div>\n<\/div>\n<h3>V2.0 \u65b0\u589e\u7684\u4e09\u6761\u786c\u5224\u636e\uff08\u8bbe\u8ba1\u9636\u6bb5\u9010\u6761\u6838\u5bf9\uff0c\u7f3a\u4e00\u6761\u4e0d\u5f97\u51fa\u56fe\uff09<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"width:16%\">\u5224\u636e<\/th>\n<th style=\"width:42%\">\u5224\u5b9a\u6761\u4ef6<\/th>\n<th>\u4e0d\u8fbe\u6807\u7684\u540e\u679c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u5224\u636e\u4e00<br \/>\u70ed\u503c<\/strong><\/td>\n<td>\u7cfb\u7edf\u603b\u8bbe\u8ba1\u70ed\u8d1f\u8377 &gt; \u58c1\u6302\u7089\u5185\u7f6e\u6c34\u6cf5\u53ef\u643a\u5e26\u70ed\u503c\uff08\u9ad8\u6e29\u5de5\u51b5\u7ea6 16 kW \/ \u4f4e\u6e29\u5de5\u51b5\u7ea6 8 kW\uff09<\/td>\n<td>\u8fdc\u7aef\u6d41\u91cf\u4e0d\u8db3\uff0c\u8fd1\u70ed\u8fdc\u51b7\u3001\u5347\u6e29\u6162\u3001\u71c3\u6c14\u6d88\u8017\u4e0a\u5347<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5224\u636e\u4e8c<br \/>\u963b\u529b<\/strong><\/td>\n<td>\u6700\u957f\u73af\u8def\u963b\u529b\uff08\u4e3b\u7ba1 + \u652f\u7ba1 + \u5206\u96c6\u6c34\u5668 + \u7089\u5185\u6362\u70ed\u5668\uff09\u8d85\u8fc7\u5185\u7f6e\u6cf5\u5269\u4f59\u626c\u7a0b<\/td>\n<td>\u5b9e\u9645\u6d41\u91cf\u4f4e\u4e8e\u8bbe\u8ba1\u503c\uff0c\u672b\u7aef\u4e0d\u70ed\uff0c\u7089\u5185\u6362\u70ed\u5668\u5c40\u90e8\u8fc7\u70ed<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5224\u636e\u4e09<br \/>\u63a7\u5236<\/strong><\/td>\n<td>\u672b\u7aef\u8981\u6c42\u81ea\u52a8\u6e29\u5305 \/ \u7535\u70ed\u6267\u884c\u5668\u505a\u53d8\u6d41\u91cf\u63a7\u5236\uff0c\u800c\u70ed\u6e90\u4e3a\u5b9a\u9891\u666e\u901a\u7089<\/td>\n<td>\u9505\u7089\u4fa7\u6d41\u91cf\u88ab\u8282\u6d41\u2192\u6362\u70ed\u6076\u5316\u3001\u9891\u7e41\u542f\u505c\u3001\u6545\u969c\u7387\u4e0a\u5347<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tiny\">\u8bf4\u660e\uff1a\u4e09\u6761\u5224\u636e\u4e2d\u4efb\u610f\u4e00\u6761\"\u4e0d\u901a\u8fc7\"\uff0c\u8bbe\u8ba1\u4e0a\u5373<strong>\u5fc5\u987b\u8bbe\u7f6e\u4e8c\u6b21\u7cfb\u7edf<\/strong>\uff08\u6c34\u529b\u5206\u538b\u5668 + \u4e8c\u6b21\u4fa7\u6c34\u6cf5\uff09\u3002\u8be6\u89c1 <a href=\"#s5\">\u7b2c\u4e94\u7ae0 \u4e8c\u6b21\u7cfb\u7edf\u4e13\u7ae0<\/a>\u3002<\/p>\n<p><!-- ===================== \u00a71 \u70ed\u6e90 ===================== --><\/p>\n<h2 id=\"s1\">\u4e8c\u3001\u7b2c\u4e00\u8981\u7d20 \u00b7 \u70ed\u6e90\uff1a\u4ea7\u70ed\u8981\"\u51c6\"<\/h2>\n<h3>2.1 \u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089\u600e\u4e48\u9009<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"width:20%\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n<th>\u666e\u901a\u7089\uff08\u5e38\u89c4\u7089\uff09<\/th>\n<th>\u51b7\u51dd\u7089\uff08\u5168\u9884\u6df7\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u71c3\u70e7\u63a7\u5236\u65b9\u5f0f<\/td>\n<td><strong>\u5b9a\u9891<\/strong>\uff0c\u5206\u9ad8 \/ \u4e2d \/ \u4f4e\u4e09\u6863<\/td>\n<td>\u53d8\u9891\u8c03\u5236\uff0c\u529f\u7387\u53ef\u8fde\u7eed\u8c03\u8282<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/td>\n<td>\u7ea6 8-10 kW<\/td>\n<td>\u7ea6 3-4 kW<\/td>\n<\/tr>\n<tr>\n<td>\u9ad8\u6e29\u5de5\u51b5\uff08\u7ea6 70\u2103\uff09\u6548\u7387<\/td>\n<td>\u7ea6 90%<\/td>\n<td>\u7ea6 88%<\/td>\n<\/tr>\n<tr>\n<td>\u4f4e\u6e29\u5de5\u51b5\uff0855\u2103 \u4ee5\u4e0b\uff09\u6548\u7387<\/td>\n<td>\u4e0b\u964d\u660e\u663e\uff0c\u5e76\u4ea7\u751f\u51b7\u51dd\u6c34\u8150\u8680\u6362\u70ed\u90e8\u4ef6<\/td>\n<td>\u53ef\u8d85\u8fc7 100%\uff08\u4f4e\u4f4d\u70ed\u503c\u53e3\u5f84\uff09\uff0c\u56de\u6536\u6f5c\u70ed<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u7f6e\u5faa\u73af\u6cf5<\/td>\n<td>\u5b9a\u901f\u6cf5\uff0c\u6d41\u91cf\u968f\u963b\u529b\u53d8\u5316<\/td>\n<td>\u591a\u4e3a\u5b9a\u901f\u6cf5\uff0c\u90e8\u5206\u673a\u578b\u4e3a\u53d8\u9891\u6cf5\uff08\u4ee5\u673a\u578b\u94ed\u724c\u4e3a\u51c6\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u7cfb\u7edf<\/td>\n<td>\u5e38\u89c4\u6696\u6c14\u7247\uff08\u9ad8\u6e29\u5de5\u51b5\uff09<\/td>\n<td>\u5730\u6696 \/ \u4f4e\u6e29\u6696\u6c14\u7247\uff08\u4f4e\u6e29\u5de5\u51b5\uff09<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5224\u5e9f\u5e74\u9650<\/strong><\/td>\n<td><strong>8 \u5e74<\/strong><\/td>\n<td><strong>8 \u5e74<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"spec-box\">\n<h3>\u3010\u4fee\u8ba2 1\u3011\u58c1\u6302\u7089\u5224\u5e9f\u5e74\u9650\uff1a\u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089\u7edf\u4e00\u6309 8 \u5e74\u6267\u884c<\/h3>\n<p style=\"margin:6px 0\">\u6309\u56fd\u5bb6\u5173\u4e8e\u5bb6\u7528\u71c3\u6c14\u71c3\u70e7\u5668\u5177\u5b89\u5168\u7ba1\u7406\u7684\u76f8\u5173\u8981\u6c42\uff0c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\uff08\u58c1\u6302\u7089\uff09\u7684\u5224\u5e9f\u5e74\u9650\u4e3a <strong>8 \u5e74<\/strong>\uff0c\u81ea\u552e\u51fa\u4e4b\u65e5\u8d77\u8ba1\u7b97\u3002<strong>\u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089\u6267\u884c\u540c\u4e00\u6807\u51c6<\/strong>\uff0c\u4e0d\u5b58\u5728\"\u51b7\u51dd\u7089\u53ef\u7528 10-15 \u5e74\"\u7684\u5dee\u5f02\u3002<\/p>\n<ul style=\"margin:6px 0 0\">\n<li>\u65b9\u6848\u4e66\u4e0e\u62a5\u4ef7\u5355\u4e2d\u6d89\u53ca\"\u8bbe\u5907\u4f7f\u7528\u5e74\u9650\"\u7684\u8868\u8ff0\uff0c\u7edf\u4e00\u5199 8 \u5e74\uff0c\u4e0d\u5f97\u4ee5\u4efb\u4f55\u5f62\u5f0f\u627f\u8bfa\u66f4\u957f\u5e74\u9650\u3002<\/li>\n<li>\u8d85\u8fc7 8 \u5e74\u7684\u5728\u7528\u9505\u7089\uff0c\u5efa\u8bae\u5728\u6539\u9020\u6216\u65b0\u589e\u7cfb\u7edf\u65f6\u540c\u6b65\u5217\u5165\u66f4\u6362\u8bc4\u4f30\uff0c\u907f\u514d\u65b0\u65e7\u7cfb\u7edf\u6df7\u7528\u5e26\u6765\u7684\u6c34\u529b\u4e0e\u5b89\u5168\u9690\u60a3\u3002<\/li>\n<li>\u5177\u4f53\u5224\u5e9f\u53e3\u5f84\u4ee5\u673a\u8eab\u94ed\u724c\u3001\u4ea7\u54c1\u8bf4\u660e\u4e66\u53ca\u73b0\u884c\u56fd\u5bb6\u6807\u51c6\u4e3a\u51c6\uff1b\u6587\u4ef6\u4e4b\u95f4\u6709\u5dee\u5f02\u65f6\uff0c\u4ee5\u66f4\u4e25\u683c\u8005\u4e3a\u51c6\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"spec-box\">\n<h3>\u3010\u4fee\u8ba2 2\u3011\u5185\u7f6e\u6c34\u6cf5\u70ed\u503c\u6838\u7b97\uff1a\u5185\u7f6e\u6cf5\u4e0d\u662f\"\u591f\u7528\"\uff0c\u800c\u662f\"\u5f88\u53ef\u80fd\u4e0d\u591f\"<\/h3>\n<p style=\"margin:6px 0\">\u58c1\u6302\u7089\u5185\u7f6e\u5faa\u73af\u6cf5\u7684\u6807\u79f0\u6d41\u91cf\u901a\u5e38\u53ea\u6709 <strong>800 L\/h\uff08\u7ea6 0.8 m\u00b3\/h\uff09\u5de6\u53f3<\/strong>\uff0c\u4e14\u8be5\u6570\u503c\u51fa\u73b0\u5728\u4f4e\u963b\u529b\u5de5\u51b5\u4e0b\uff1b\u63a5\u5165\u5b9e\u9645\u7cfb\u7edf\u540e\uff0c\u53d7\u7ba1\u8def\u4e0e\u6362\u70ed\u5668\u963b\u529b\u5f71\u54cd\uff0c\u53ef\u7528\u6d41\u91cf\u5f80\u5f80\u8fd8\u8981\u6253\u6298\u6263\u3002\u70ed\u91cf\u662f\u9760\u6c34\"\u8fd0\"\u51fa\u53bb\u7684\uff0c\u6d41\u91cf\u4e00\u65e6\u5c01\u9876\uff0c\u80fd\u5e26\u51fa\u53bb\u7684\u70ed\u503c\u5c31\u5c01\u9876\u3002<\/p>\n<div class=\"formula\">\n\u70ed\u503c\u901f\u7b97\u5f0f\uff08\u5de5\u7a0b\u4fdd\u5b88\u53d6\u503c\uff0c\u5df2\u542b\u5b89\u5168\u4f59\u91cf\uff09\uff1a<br \/>\n\u3000Q\uff08kW\uff09 \u2248 q\uff08m\u00b3\/h\uff09 \u00d7 \u0394t\uff08K\uff09 \u00d7 1.0<\/p>\n<p>\u2460 \u9ad8\u6e29\u5de5\u51b5\uff0c\u4f9b\u56de\u6c34\u6e29\u5dee \u0394t = 20\u2103\uff1a<br \/>\n\u3000Q \u2248 0.8 \u00d7 20 \u00d7 1.0 \u2248 <strong>16 kW<\/strong><br \/>\n\u2461 \u4f4e\u6e29\u5de5\u51b5\uff0c\u4f9b\u56de\u6c34\u6e29\u5dee \u0394t = 10\u2103\uff1a<br \/>\n\u3000Q \u2248 0.8 \u00d7 10 \u00d7 1.0 \u2248 <strong>8 kW<\/strong><br \/>\n<span class=\"tiny\">\uff08\u6309\u6c34\u6bd4\u70ed 1.163 \u7cfb\u6570\u7406\u8bba\u8ba1\u7b97\u5206\u522b\u4e3a\u7ea6 18.6 kW \u4e0e 9.3 kW\uff1b\u5de5\u7a0b\u53d6\u503c\u5df2\u6263\u51cf\u5185\u7f6e\u6cf5\u5728\u5b9e\u9645\u963b\u529b\u4e0b\u7684\u626c\u7a0b\u8870\u51cf\uff0c\u8bbe\u8ba1\u4e0a\u4ee5 16 kW \/ 8 kW \u4e3a\u4e0a\u9650\u3002\uff09<\/span>\n<\/div>\n<table>\n<thead>\n<tr>\n<th style=\"width:26%\">\u5de5\u51b5<\/th>\n<th style=\"width:22%\">\u4f9b\u56de\u6c34\u6e29\u5dee<\/th>\n<th style=\"width:24%\">\u5185\u7f6e\u6cf5\u53ef\u643a\u5e26\u70ed\u503c<\/th>\n<th>\u5224\u5b9a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5e38\u89c4\u6696\u6c14\u7247\uff08\u9ad8\u6e29\uff09<\/td>\n<td>\u0394t = 20\u2103<\/td>\n<td><strong>\u7ea6 16 kW<\/strong><\/td>\n<td>\u7cfb\u7edf\u603b\u8d1f\u8377 &gt; 16 kW \u2192 \u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u4f4e\u6e29\u6696\u6c14\u7247<\/td>\n<td>\u0394t = 10\u2103<\/td>\n<td><strong>\u7ea6 8 kW<\/strong><\/td>\n<td>\u7cfb\u7edf\u603b\u8d1f\u8377 &gt; 8 kW \u2192 \u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>\u7b97\u4f8b\uff08\u6210\u90fd\u4f4f\u5b85\u5e38\u89c1\u573a\u666f\uff09<\/h4>\n<ul>\n<li><strong>120 \u33a1 \u4fdd\u6e29\u4e00\u822c\u7684\u65b0\u623f<\/strong>\uff0c\u70ed\u8d1f\u8377\u6309 110 W\/\u33a1 \u53d6\u503c \u2192 \u603b\u8d1f\u8377\u7ea6 <strong>13.2 kW<\/strong>\u3002\u9ad8\u6e29\u5de5\u51b5\u4e0b 13.2 kW &lt; 16 kW\uff0c\u5185\u7f6e\u6cf5\u70ed\u503c\u52c9\u5f3a\u591f\uff0c\u53ef\u4e0d\u505a\u4e8c\u6b21\u7cfb\u7edf\uff1b\u4f46\u9700\u7ee7\u7eed\u6838\u5bf9\u5224\u636e\u4e8c\uff08\u963b\u529b\uff09\u3002<\/li>\n<li><strong>120 \u33a1 \u4fdd\u6e29\u504f\u5dee \/ \u9876\u5c42 \/ \u5927\u843d\u5730\u7a97<\/strong>\uff0c\u70ed\u8d1f\u8377\u6309 140 W\/\u33a1 \u53d6\u503c \u2192 \u603b\u8d1f\u8377\u7ea6 <strong>16.8 kW<\/strong>\u3002\u5df2\u8d85\u8fc7 16 kW \u4e0a\u9650\uff0c<strong>\u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/strong>\u3002<\/li>\n<li><strong>\u540c\u6237\u578b\u6539\u4f4e\u6e29\u6696\u6c14\u7247\uff08\u0394t=10\u2103\uff09<\/strong>\uff0c\u603b\u8d1f\u8377 13.2 kW &gt; 8 kW\uff0c<strong>\u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/strong>\u2014\u2014\u4f4e\u6e29\u5de5\u51b5\u5bf9\u6d41\u91cf\u7684\u9700\u6c42\u7ea6\u4e3a\u9ad8\u6e29\u5de5\u51b5\u7684\u4e24\u500d\uff0c\u8fd9\u4e5f\u662f\u4f4e\u6e29\u6696\u6c14\u7247\u8bbe\u8ba1\u4e2d\u6700\u5bb9\u6613\u88ab\u5ffd\u7565\u7684\u4e00\u73af\u3002<\/li>\n<\/ul>\n<p class=\"tiny\">\u6210\u90fd\u5730\u533a\u4f4f\u5b85\u70ed\u8d1f\u8377\u53d6\u503c\u533a\u95f4 100-140 W\/\u33a1\uff0c\u672c\u9875\u7b97\u4f8b\u53d6\u503c\u4e3a\u8bf4\u660e\u65b9\u6cd5\uff0c\u5b9e\u9645\u4ee5\u73b0\u573a\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b\u7ed3\u679c\u4e3a\u51c6\u3002<\/p>\n<\/div>\n<h3>2.2 \u907f\u514d\u9505\u7089\u9891\u7e41\u542f\u505c<\/h3>\n<p>\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u7ea6 8-10 kW\uff0c\u800c\u5f53\u53ea\u6709 1-2 \u7ec4\u6696\u6c14\u7247\u5f00\u542f\u65f6\uff0c\u5b9e\u9645\u6563\u70ed\u9700\u6c42\u53ef\u80fd\u4ec5 2-3 kW\u3002\u4ea7\u70ed\u5927\u4e8e\u6563\u70ed\uff0c\u6c34\u6e29\u8fc5\u901f\u5230\u8bbe\u5b9a\u503c\u2192\u505c\u673a\uff0c\u6c34\u6e29\u4e0b\u964d\u2192\u91cd\u65b0\u70b9\u706b\uff0c\u5982\u6b64\u53cd\u590d\uff0c\u4e0d\u4ec5\u8d39\u6c14\uff0c\u4e5f\u52a0\u901f\u8bbe\u5907\u635f\u8017\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"width:28%\">\u63aa\u65bd<\/th>\n<th>\u505a\u6cd5\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u91c7\u6696\u4e0e\u751f\u6d3b\u70ed\u6c34\u5206\u79bb<\/td>\n<td>\u4fdd\u7559\u70ed\u6c34\u5668\u8d1f\u8d23\u751f\u6d3b\u70ed\u6c34\uff0c\u9505\u7089\u53ea\u627f\u62c5\u91c7\u6696\uff0c\u907f\u514d\u6a21\u5f0f\u9891\u7e41\u5207\u6362<\/td>\n<\/tr>\n<tr>\n<td>\u5206\u6bb5\u71c3\u70e7 \/ \u53d8\u9891\u8c03\u5236<\/td>\n<td>\u9009\u62e9\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u66f4\u4f4e\u7684\u673a\u578b\uff0c\u5339\u914d\u5c0f\u8d1f\u8377\u9700\u6c42<\/td>\n<\/tr>\n<tr>\n<td>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/td>\n<td>\u5ba4\u6e29\u8fbe\u6807\u5373\u505c\u673a\uff0c\u6309\u9700\u4f9b\u70ed\uff0c\u907f\u514d\u65e0\u6548\u4ea7\u70ed<\/td>\n<\/tr>\n<tr>\n<td>\u5408\u7406\u589e\u52a0\u540c\u5f00\u7ec4\u6570<\/td>\n<td>\u8ba9\u672b\u7aef\u6563\u70ed\u603b\u91cf\u4e0e\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u76f8\u5339\u914d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>2.3 \u9505\u7089\u529f\u7387\u9009\u578b\uff1a\u91c7\u6696\u4e0e\u70ed\u6c34\u5206\u5f00\u7b97<\/h3>\n<p>\u5e38\u89c1\u505a\u6cd5\u662f\u7528\u4e00\u53f0\u4e24\u7528\u7089\u540c\u65f6\u5e26\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\uff0c\u7ed3\u679c\u4e24\u8fb9\u90fd\u4e0d\u591f\u7528\u3002\u6b63\u786e\u505a\u6cd5\u662f\uff1a\u91c7\u6696\u529f\u7387\u6309\u623f\u5c4b\u70ed\u8d1f\u8377\u8ba1\u7b97\uff08\u6210\u90fd\u4f4f\u5b85 100-140 W\/\u33a1\uff09\uff0c\u751f\u6d3b\u70ed\u6c34\u53e6\u7531\u70ed\u6c34\u5668\u627f\u62c5\uff0c\u4e24\u5957\u7cfb\u7edf\u5404\u53f8\u5176\u804c\u3002<\/p>\n<figure style=\"margin:16px 0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-glgdylw.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u58c1\u6302\u7089\u7ba1\u9053\u9884\u7559\u4f4d\" loading=\"lazy\"><figcaption>\u9505\u7089\u7ba1\u9053\u9884\u7559\u4f4d\uff08\u53cc\u6d41 \u00b7 \u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u5de5\u5730\u5b9e\u62cd\uff09\uff1a\u9505\u7089\u4f4d\u9700\u5728\u6c34\u7535\u9636\u6bb5\u540c\u6b65\u9884\u7559\u51b7\u70ed\u6c34\u3001\u71c3\u6c14\u3001\u7535\u6e90\u4e0e\u70df\u9053\u6d1e\u53e3\uff0c\u5899\u9762\u627f\u91cd\u4e0e\u68c0\u4fee\u7a7a\u95f4\u4e00\u5e76\u6838\u5b9e\u3002<\/figcaption><\/figure>\n<div style=\"margin:14px 0\">\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10982\" target=\"_blank\"><span class=\"title\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c\u9875<\/span><span class=\"desc\">\u5df2\u88c5\u4fee\u623f\u9009\u660e\u88c5\uff1a\u7ba1\u6750\u8d70\u5411\u3001\u5de5\u671f\u4e0e\u914d\u7f6e\u5bf9\u7167<\/span><\/a><br \/>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\"><span class=\"title\">\u7cbe\u5de5\u516d\u6b65\u6cd5\u603b\u89c8<\/span><span class=\"desc\">\u9f99\u8109\u6696\u901a\u65bd\u5de5\u6807\u51c6\u4e0e\u5de5\u5e8f\u7ba1\u7406\u8981\u6c42<\/span><\/a>\n<\/div>\n<p><!-- ===================== \u00a72 \u8f93\u914d ===================== --><\/p>\n<h2 id=\"s2\">\u4e09\u3001\u7b2c\u4e8c\u8981\u7d20 \u00b7 \u8f93\u914d\uff1a\u8fd0\u70ed\u8981\"\u901a\"<\/h2>\n<h3>3.1 \u6697\u57cb\u5fc5\u987b\u7528\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668<\/h3>\n<p>\u660e\u88c5\u7ba1\u9053\u6cbf\u8e22\u811a\u7ebf\u6216\u9876\u9762\u8d70\uff0c\u5f02\u7a0b\u5e03\u7ba1\u6210\u672c\u4f4e\uff1b\u800c\u6697\u57cb\u7ba1\u9053\u57cb\u5728\u5730\u9762\u4e0b\uff0c\u4e00\u65e6\u6e17\u6f0f\u9700\u7838\u5730\u7ef4\u4fee\uff0c\u56e0\u6b64<strong>\u5fc5\u987b\u91c7\u7528\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668\u7cfb\u7edf<\/strong>\u2014\u2014\u6bcf\u4e00\u8def\u7ba1\u9053\u4ece\u5206\u96c6\u6c34\u5668\u72ec\u7acb\u51fa\u53d1\u5230\u4e00\u7ec4\u6696\u6c14\u7247\uff0c\u518d\u72ec\u7acb\u8fd4\u56de\uff0c\u5404\u652f\u8def\u4e92\u4e0d\u5e72\u6270\uff0c\u4fbf\u4e8e\u5355\u72ec\u68c0\u4fee\u4e0e\u8c03\u8282\u3002<\/p>\n<div class=\"fig-grid\">\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-fjsx.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u5206\u96c6\u6c34\u7bb1\u5b89\u88c5\" loading=\"lazy\"><figcaption>\u5206\u96c6\u6c34\u7bb1\u5b89\u88c5\uff1a\u7bb1\u4f53\u4f4d\u7f6e\u9700\u517c\u987e\u68c0\u4fee\u53ef\u8fbe\u6027\u4e0e\u5404\u56de\u8def\u8d70\u5411\uff0c\u907f\u514d\u7f6e\u4e8e\u67dc\u4f53\u6df1\u5904\u6216\u88ab\u56fa\u5b9a\u5bb6\u5177\u906e\u6321\u3002<\/figcaption><\/figure>\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-fjsq.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u5206\u96c6\u6c34\u5668\" loading=\"lazy\"><figcaption>\u5206\u96c6\u6c34\u5668\uff1a\u5404\u652f\u8def\u72ec\u7acb\u4f9b\u56de\uff0c\u914d\u89d2\u5f0f\u7403\u9600\u4e0e\u672b\u7aef\u5c3e\u4ef6\uff08\u6392\u6c14\u3001\u6cc4\u6c34\u3001\u538b\u529b\u8868\uff09\uff0c\u662f\u540e\u671f\u6c34\u529b\u5e73\u8861\u8c03\u8282\u7684\u64cd\u4f5c\u754c\u9762\u3002<\/figcaption><\/figure>\n<\/div>\n<h3>3.2 \u4e3b\u7ba1\u8981\"\u5927\"\uff1a\u7ba1\u5f84\u51b3\u5b9a\u80fd\u8fd0\u591a\u5c11\u70ed<\/h3>\n<p>\u6c34\u6d41\u91cf\u51b3\u5b9a\u70ed\u91cf\u8f93\u9001\u80fd\u529b\u3002\u4e3b\u7ba1\u7ba1\u5f84\u504f\u5c0f\uff0c\u6cbf\u7a0b\u963b\u529b\u5927\uff0c\u8fdc\u7aef\u6696\u6c14\u7247\u6d41\u91cf\u4e0d\u8db3\uff0c\u5c31\u4f1a\u51fa\u73b0\"\u8fd1\u70ed\u8fdc\u51b7\"\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th>\u7ba1\u5f84<\/th>\n<th>\u5185\u5f84<\/th>\n<th>\u53c2\u8003\u6d41\u91cf<\/th>\n<th>10\u2103\u6e29\u5dee\u53ef\u643a\u5e26\u70ed\u503c<\/th>\n<th>\u5efa\u8bae\u6d41\u901f<\/th>\n<th>\u9002\u7528\u90e8\u4f4d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>De16<\/td>\n<td>12 mm<\/td>\n<td>\u7ea6 100 L\/h<\/td>\n<td>\u7ea6 1.2 kW<\/td>\n<td>\u22640.5 m\/s<\/td>\n<td>\u6696\u6c14\u7247\u652f\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>De20<\/td>\n<td>16 mm<\/td>\n<td>\u7ea6 200 L\/h<\/td>\n<td>\u7ea6 2.3 kW<\/td>\n<td>\u22640.5 m\/s<\/td>\n<td>\u5c0f\u6237\u578b\u652f\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>De25<\/td>\n<td>20 mm<\/td>\n<td>\u7ea6 500 L\/h<\/td>\n<td>\u7ea6 5.8 kW<\/td>\n<td>\u22641.0 m\/s<\/td>\n<td>\u4e2d\u5c0f\u6237\u578b\u4e3b\u7ba1<\/td>\n<\/tr>\n<tr style=\"background:#fdf1ee\">\n<td><strong>De32<\/strong><\/td>\n<td><strong>26 mm<\/strong><\/td>\n<td><strong>\u7ea6 1,000 L\/h<\/strong><\/td>\n<td><strong>\u7ea6 11.6 kW<\/strong><\/td>\n<td><strong>\u22641.0 m\/s<\/strong><\/td>\n<td><strong>\u4e3b\u6d41\u6237\u578b\u4e3b\u7ba1\uff08\u6697\u57cb\u8d77\u6b65\u89c4\u683c\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>De40<\/td>\n<td>32 mm<\/td>\n<td>\u7ea6 2,000 L\/h<\/td>\n<td>\u7ea6 23.2 kW<\/td>\n<td>\u22641.0 m\/s<\/td>\n<td>\u5927\u6237\u578b \/ \u522b\u5885\u4e3b\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>De50<\/td>\n<td>40 mm<\/td>\n<td>\u7ea6 5,000 L\/h<\/td>\n<td>\u7ea6 58 kW<\/td>\n<td>\u22641.5 m\/s<\/td>\n<td>\u522b\u5885 \/ \u5927\u9762\u79ef\u4e3b\u7ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u89c4\u8303\u8981\u6c42\uff1a<\/strong>\u6697\u57cb\u6696\u6c14\u7247\u4e3b\u7ba1\u8d77\u6b65\u89c4\u683c\u4e3a <strong>De32<\/strong>\u3002\u4ee5 100-140 \u33a1 \u6237\u578b\u4e3a\u4f8b\uff0cDe32 \u5728 10\u2103 \u6e29\u5dee\u4e0b\u53ef\u643a\u5e26\u7ea6 11.6 kW \u70ed\u503c\uff0c\u53ef\u8986\u76d6\u51ac\u5b63\u591a\u6570\u65f6\u6bb5\u9700\u6c42\uff1bDe25 \u4ec5\u7ea6 5.8 kW\uff0c\u5728\u6700\u51b7\u65f6\u6bb5\u6613\u51fa\u73b0\u80fd\u529b\u4e0d\u8db3\u3002<\/p>\n<h3>3.3 \u5f2f\u5934\u8981\"\u5927\"\uff1a\u7528\u5927\u5f27\u5f2f\uff0c\u4e0d\u7528\u76f4\u89d2\u5f2f<\/h3>\n<p>\u6309\u76f8\u5173\u65bd\u5de5\u89c4\u8303\u8981\u6c42\uff0c\u94dd\u5851\u590d\u5408\u7ba1\u5f2f\u66f2\u534a\u5f84\u4e0d\u5e94\u5c0f\u4e8e\u7ba1\u9053\u5916\u5f84\u7684 <strong>6 \u500d<\/strong>\uff0c\u5851\u6599\u7ba1\u4e0d\u5e94\u5c0f\u4e8e <strong>8 \u500d<\/strong>\u3002\u76f4\u89d2\u5f2f\u7684\u5c40\u90e8\u963b\u529b\u7cfb\u6570\u7ea6\u4e3a 1.0-1.5\uff0c\u800c\u5f2f\u7ba1\u5668\u5f2f\u5236\u7684\u5927\u5f27\u5f2f\u7ea6\u4e3a 0.3-0.5\u2014\u2014\u76f4\u89d2\u5f2f\u76f8\u5f53\u4e8e\u9ad8\u901f\u8def\u7a81\u7136\u6536\u7a84\u6210\u5355\u8f66\u9053\uff0c\u6240\u6709\u6c34\u6d41\u90fd\u8981\u51cf\u901f\u6392\u961f\u901a\u8fc7\u3002<\/p>\n<figure style=\"margin:16px 0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-zgjdhwjk.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u4e3b\u7ba1\u53ca\u5927\u5f27\u5f2f\u63a5\u53e3\" loading=\"lazy\"><figcaption>\u4e3b\u7ba1\u53ca\u5927\u5f27\u5f2f\u63a5\u53e3\uff1aDe32 \u4e3b\u7ba1\u91c7\u7528\u5f2f\u7ba1\u5668\u5f2f\u5236\uff0c\u5f2f\u5236\u534a\u5f84\u4e0d\u5c0f\u4e8e 6 \u500d\u7ba1\u5916\u5f84\uff08\u7ea6 \u226596 mm\uff09\uff0c\u907f\u514d\u76f4\u89d2\u5f2f\u5934\u5f62\u6210\u5c40\u90e8\u963b\u529b\u74f6\u9888\u3002<\/figcaption><\/figure>\n<h3>3.4 \u652f\u7ba1\u5fc5\u987b\u7edd\u6c27\uff1a\u94dd\u5851\u590d\u5408\u7ba1<\/h3>\n<p>\u94a2\u5236\u6696\u6c14\u7247\u6700\u6015\u6c27\u6c14\u8150\u8680\u2014\u2014\u6c34\u4e2d\u6eb6\u89e3\u6c27\u4e0e\u94a2\u5236\u6563\u70ed\u5668\u53d1\u751f\u6c27\u5316\u53cd\u5e94\uff0c\u751f\u6210\u94c1\u9508\u94c1\u6ce5\uff0c\u9010\u6b65\u5835\u585e\u7ba1\u9053\u4e0e\u9505\u7089\u6362\u70ed\u5668\u3002\u652f\u7ba1\u7ba1\u6750\u7684\u963b\u6c27\u80fd\u529b\uff0c\u76f4\u63a5\u51b3\u5b9a\u7cfb\u7edf\u5bff\u547d\u3002<\/p>\n<table>\n<thead>\n<tr>\n<th>\u7ba1\u6750<\/th>\n<th>\u963b\u6c27\u6027\u80fd<\/th>\n<th>\u6696\u6c14\u7247\u7cfb\u7edf\u9002\u7528\u6027<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u666e\u901a PE-RT \u7ba1<\/td>\n<td>\u4e0d\u963b\u6c27<\/td>\n<td>\u4e0d\u9002\u7528<\/td>\n<\/tr>\n<tr>\n<td>\u5e26 EVOH \u963b\u6c27\u5c42 PE-RT \u7ba1<\/td>\n<td>\u963b\u6c27\uff0c\u4f46\u975e\u5b8c\u5168\u963b\u6c27\uff0c\u957f\u671f\u4f7f\u7528\u6027\u80fd\u4f1a\u8870\u51cf<\/td>\n<td>\u53ef\u7528<\/td>\n<\/tr>\n<tr style=\"background:#fdf1ee\">\n<td><strong>\u94dd\u5851\u590d\u5408\u7ba1\uff08XPAP\uff09<\/strong><\/td>\n<td><strong>\u4e2d\u95f4\u94dd\u5c42\u4e3a\u81f4\u5bc6\u91d1\u5c5e\u5c42\uff0c\u6c27\u6c14\u65e0\u6cd5\u7a7f\u900f<\/strong><\/td>\n<td><strong>\u6697\u57cb\u652f\u7ba1\u9996\u9009<\/strong><\/td>\n<\/tr>\n<tr>\n<td>PB \u7ba1<\/td>\n<td>\u4e0d\u963b\u6c27<\/td>\n<td>\u4e0d\u9002\u7528<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u89c4\u8303\u8981\u6c42\uff1a<\/strong>\u6697\u57cb\u6696\u6c14\u7247\u652f\u7ba1\u91c7\u7528 <strong>\u94dd\u5851\u590d\u5408\u7ba1 De16\u00d72.2<\/strong>\uff0c\u53ef\u5f2f\u66f2\u3001\u4e00\u7ba1\u5230\u5e95\u65e0\u63a5\u5934\uff0c\u540c\u65f6\u4e2d\u95f4\u94dd\u5c42\u5b9e\u73b0\u5b8c\u5168\u7edd\u6c27\u3002<\/p>\n<h3>3.5 \u57cb\u5730\u65e0\u63a5\u5934\uff1a\u4e00\u7ba1\u5230\u5e95<\/h3>\n<p>\u6309\u76f8\u5173\u89c4\u8303\u8981\u6c42\uff0c\u57cb\u8bbe\u4e8e\u586b\u5145\u5c42\u5185\u7684\u52a0\u70ed\u4f9b\u51b7\u7ba1\u53ca\u8f93\u914d\u7ba1<strong>\u4e0d\u5e94\u6709\u63a5\u5934<\/strong>\uff1b\u94fa\u8bbe\u8fc7\u7a0b\u4e2d\u51fa\u73b0\u635f\u574f\u6216\u6e17\u6f0f\u65f6\uff0c\u5e94<strong>\u6574\u6839\u66f4\u6362<\/strong>\uff0c\u4e0d\u5f97\u62fc\u63a5\u4f7f\u7528\u3002\u63a5\u5934\u662f\u7cfb\u7edf\u6700\u8584\u5f31\u7684\u73af\u8282\uff0c\u70ed\u80c0\u51b7\u7f29\u540e\u5bc6\u5c01\u5931\u6548\u98ce\u9669\u6700\u9ad8\uff0c\u800c\u5730\u9762\u4e0b\u6e17\u6f0f\u5f80\u5f80\u53d1\u73b0\u65f6\u5df2\u9020\u6210\u5927\u9762\u79ef\u6ce1\u6c34\u3002<\/p>\n<div class=\"fig-grid\">\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-zgzg-01.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u652f\u7ba1\u8d70\u7ba101\" loading=\"lazy\"><figcaption>\u652f\u7ba1\u8d70\u7ba1 01\uff1a\u5206\u96c6\u6c34\u5668\u51fa\u7ba1\u6392\u5217\uff0c\u56de\u8def\u95f4\u8ddd\u4e0e\u56fa\u5b9a\u5361\u95f4\u8ddd\u5747\u5300\u3002<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-zgzg-02.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u652f\u7ba1\u8d70\u7ba102\" loading=\"lazy\"><figcaption>\u652f\u7ba1\u8d70\u7ba1 02\uff1a\u8f6c\u5f2f\u5904\u91c7\u7528\u5927\u5f27\u5f2f\uff0c\u65e0\u76f4\u89d2\u6298\u5f2f\u4e0e\u63a5\u5934\u3002<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-zgzg-03.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u652f\u7ba1\u8d70\u7ba103\" loading=\"lazy\"><figcaption>\u652f\u7ba1\u8d70\u7ba1 03\uff1a\u6574\u7ba1\u94fa\u8bbe\uff0c\u7a7f\u8d8a\u90e8\u4f4d\u52a0\u4fdd\u62a4\u5957\u7ba1\u3002<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-zgzg-04.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u652f\u7ba1\u8d70\u7ba104\" loading=\"lazy\"><figcaption>\u652f\u7ba1\u8d70\u7ba1 04\uff1a\u4e0e\u4e3b\u7ba1\u8854\u63a5\u89c4\u6574\uff0c\u4e3a\u540e\u7eed\u6253\u538b\u4e0e\u56de\u586b\u7559\u51fa\u4f5c\u4e1a\u9762\u3002<\/figcaption><\/figure>\n<\/div>\n<div class=\"chk\"><strong>\u2705 \u9690\u853d\u524d\u9a8c\u6536\u8981\u70b9\uff1a<\/strong>\u7ba1\u8def\u94fa\u8bbe\u5b8c\u6210\u3001\u56de\u586b\u5c01\u69fd\u524d\u5fc5\u987b\u505a<strong>\u6253\u538b\u6d4b\u8bd5<\/strong>\u2014\u2014\u6253\u538b\u81f3 0.6-0.8 MPa\uff0c\u4fdd\u538b 24 \u5c0f\u65f6\u65e0\u964d\u538b\u4e3a\u5408\u683c\uff1b\u7cfb\u7edf\u5168\u90e8\u5b89\u88c5\u5b8c\u6210\u540e\u518d\u505a\u7b2c\u4e8c\u6b21\u8bd5\u538b\u4e0e\u8c03\u8bd5\u3002<\/div>\n<h3>3.6 \u7ba1\u8def\u4fdd\u6e29<\/h3>\n<p>\u6697\u57cb\u7ba1\u9053\u82e5\u4e0d\u505a\u4fdd\u6e29\uff0c\u70ed\u6c34\u5728\u8f93\u9001\u9014\u4e2d\u7684\u70ed\u91cf\u4f1a\u6301\u7eed\u5411\u697c\u677f\u6563\u5931\u3002\u4e3b\u652f\u7ba1\u5747\u9700\u5305\u8986\u6a61\u5851\u4fdd\u6e29\u7ba1\uff1a\u4e3b\u7ba1 De32 \u914d \u00d832 \u4fdd\u6e29\u7ba1\uff08\u539a\u5ea6 \u226520 mm\uff09\uff0c\u652f\u7ba1 De16 \u914d \u00d816 \u4fdd\u6e29\u7ba1\uff08\u539a\u5ea6 \u226510 mm\uff09\u3002<\/p>\n<div style=\"margin:14px 0\">\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\"><span class=\"title\">\u670d\u52a1\u4fdd\u969c<\/span><span class=\"desc\">\u9690\u853d\u5de5\u7a0b\u4fdd\u4fee\u8303\u56f4\u4e0e\u54cd\u5e94\u65f6\u6548<\/span><\/a>\n<\/div>\n<p><!-- ===================== \u00a73 \u672b\u7aef ===================== --><\/p>\n<h2 id=\"s3\">\u56db\u3001\u7b2c\u4e09\u8981\u7d20 \u00b7 \u672b\u7aef\uff1a\u6563\u70ed\u8981\"\u591f\"<\/h2>\n<h3>4.1 \u6696\u6c14\u7247\u9009\u578b\uff1a\u5148\u786e\u5b9a\u6309\u54ea\u4e2a\u6e29\u5dee\u7b97<\/h3>\n<p>\u6696\u6c14\u7247\u6807\u79f0\u6563\u70ed\u529f\u7387\u662f\u6309<strong>\u6807\u51c6\u6e29\u5dee \u0394t = 20\u2103<\/strong> \u6807\u5b9a\u7684\uff08\u5982\u4f9b\u6c34 70\u2103\u3001\u56de\u6c34 50\u2103\u3001\u5ba4\u6e29 20\u2103\uff09\u3002\u5de5\u51b5\u4e00\u53d8\uff0c\u5b9e\u9645\u6563\u70ed\u91cf\u968f\u4e4b\u6539\u53d8\uff1a<\/p>\n<ul>\n<li><strong>\u914d\u666e\u901a\u7089\uff08\u9ad8\u6e29\u7cfb\u7edf\uff0c\u4f9b\u6c34 70-80\u2103\uff09\uff1a<\/strong>\u6309\u6807\u51c6\u6e29\u5dee\u8ba1\u7b97\uff0c\u6210\u90fd\u4f4f\u5b85\u6bcf\u5e73\u65b9\u7c73\u70ed\u8d1f\u8377\u53d6 100-140 W\uff0c\u6696\u6c14\u7247\u65e0\u9700\u989d\u5916\u653e\u5927\u3002<\/li>\n<li><strong>\u914d\u51b7\u51dd\u7089\uff08\u4f4e\u6e29\u6696\u6c14\u7247\uff0c\u4f9b\u6c34 \u226455\u2103\uff09\uff1a<\/strong>\u9700\u6309\u4f4e\u6e29\u6696\u6c14\u7247\u8bbe\u8ba1\uff0c\u901a\u8fc7\u589e\u52a0\u7ec4\u6570\u6216\u52a0\u5927\u6563\u70ed\u9762\u79ef\u6765\u8865\u507f\u2014\u2014\u4f4e\u6e29\uff0855\u2103\uff09\u5de5\u51b5\u4e0b\u6563\u70ed\u529f\u7387\u7ea6\u4e3a\u9ad8\u6e29\uff0870\u2103\uff09\u5de5\u51b5\u7684 60%-70%\uff0c\u5dee\u8ddd\u7ea6 30%-40%\u3002<\/li>\n<\/ul>\n<h3>4.2 \u5b89\u88c5\u4f4d\u7f6e\u4e0e\u9884\u7559\u7ba1\u8def\u5e03\u5c40<\/h3>\n<p>\u6696\u6c14\u7247\u4f18\u5148\u5e03\u7f6e\u5728<strong>\u7a97\u6237\u4e0b\u65b9\u6216\u5916\u5899\u4f4d\u7f6e<\/strong>\u3002\u51b7\u7a7a\u6c14\u4ece\u7a97\u7f1d\u4e0e\u5916\u5899\u6e17\u5165\uff0c\u6696\u6c14\u7247\u4e0a\u5347\u7684\u70ed\u6c14\u6d41\u5f62\u6210\"\u6c14\u5e18\"\uff0c\u65e2\u963b\u6321\u51b7\u7a7a\u6c14\u8fdb\u5165\uff0c\u53c8\u76f4\u63a5\u52a0\u70ed\u5df2\u6e17\u5165\u7684\u51b7\u7a7a\u6c14\uff0c\u662f\u6548\u7387\u6700\u9ad8\u7684\u5e03\u7f6e\u65b9\u5f0f\u3002<\/p>\n<div class=\"fig-grid\">\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-nqpyllgbj-01.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c4001\" loading=\"lazy\"><figcaption>\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c40 01\uff1a\u7a97\u4e0b\u5b9a\u4f4d\uff0c\u9884\u7559\u652f\u7ba1\u51fa\u5899\u4f4d\u7f6e\u4e0e\u4e2d\u5fc3\u8ddd\u3002<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-nqpyllgbj-02.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c4002\" loading=\"lazy\"><figcaption>\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c40 02\uff1a\u4f9b\u56de\u6c34\u7ba1\u95f4\u8ddd\u4e0e\u5899\u9762\u5b8c\u6210\u9762\u5173\u7cfb\uff0c\u9700\u5728\u62b9\u7070\u524d\u590d\u6838\u3002<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-nqpyllgbj-03.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c4003\" loading=\"lazy\"><figcaption>\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c40 03\uff1a\u4e0e\u63d2\u5ea7\u3001\u5bb6\u5177\u3001\u7a97\u5e18\u76d2\u7684\u4f4d\u7f6e\u907f\u8ba9\u3002<\/figcaption><\/figure>\n<figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-nqpyllgbj-04.jpg\" alt=\"\u6210\u90fd\u53cc\u6d41\u533a\u56fd\u680b\u5357\u56ed\u4e94\u661f\u57ce\u6697\u57cb\u6696\u6c14\u7247\u5de5\u5730\u5b9e\u62cd-\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c4004\" loading=\"lazy\"><figcaption>\u6696\u6c14\u7247\u9884\u7559\u7ba1\u8def\u5e03\u5c40 04\uff1a\u6302\u7247\u652f\u67b6\u9884\u57cb\u4f4d\u7f6e\u4e0e\u627f\u91cd\u6838\u5b9e\u3002<\/figcaption><\/figure>\n<\/div>\n<div class=\"warn-box\"><strong>\u73b0\u573a\u9ad8\u9891\u8e29\u5751\uff1a<\/strong>\u9884\u7559\u7ba1\u8def\u6309\"\u6bdb\u576f\u5899\u9762\"\u5b9a\u4f4d\uff0c\u7b49\u5230\u8d34\u7816\u6216\u505a\u6728\u9970\u9762\u540e\u518d\u88c5\u6696\u6c14\u7247\uff0c\u53d1\u73b0\u7ba1\u53e3\u88ab\u5899\u9762\u5b8c\u6210\u9762\u5403\u6389\u3001\u4e2d\u5fc3\u8ddd\u5bf9\u4e0d\u4e0a\u3002<strong>\u9884\u7559\u9636\u6bb5\u5fc5\u987b\u628a\u5899\u9762\u3001\u5730\u9762\u5b8c\u6210\u9762\u539a\u5ea6\u8ba1\u5165<\/strong>\uff0c\u5e76\u5728\u56fe\u7eb8\u4e0a\u6807\u6ce8\u5b8c\u6210\u9762\u57fa\u51c6\u3002<\/div>\n<h3>4.3 \u6750\u8d28\u9009\u62e9<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u6750\u8d28<\/th>\n<th>\u5bfc\u70ed\u901f\u5ea6<\/th>\n<th>\u8010\u8150\u8680\u6027<\/th>\n<th>\u91cd\u91cf<\/th>\n<th>\u9002\u7528\u7cfb\u7edf<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u94a2\u5236\u677f\u5f0f<\/td>\n<td>\u5feb<\/td>\n<td>\u4e2d\u7b49\uff08\u4f9d\u8d56\u7edd\u6c27\u7cfb\u7edf\uff09<\/td>\n<td>\u8f7b<\/td>\n<td>\u71c3\u6c14\u9505\u7089\u7cfb\u7edf<\/td>\n<\/tr>\n<tr style=\"background:#fdf1ee\">\n<td><strong>\u94dc\u94dd\u590d\u5408<\/strong><\/td>\n<td><strong>\u5feb<\/strong><\/td>\n<td><strong>\u5f3a<\/strong><\/td>\n<td><strong>\u4e2d\u7b49<\/strong><\/td>\n<td><strong>\u5404\u7c7b\u7cfb\u7edf\uff0c\u5bff\u547d\u957f\uff08\u6697\u57cb\u63a8\u8350\uff09<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u94f8\u94dd<\/td>\n<td>\u5feb<\/td>\n<td>\u4e2d\u7b49<\/td>\n<td>\u8f7b<\/td>\n<td>\u71c3\u6c14\u9505\u7089\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u94f8\u94c1<\/td>\n<td>\u6162<\/td>\n<td>\u5f3a<\/td>\n<td>\u91cd<\/td>\n<td>\u96c6\u4e2d\u4f9b\u6696\u7cfb\u7edf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u6697\u57cb\u7cfb\u7edf\u5efa\u8bae\u9009<strong>\u94dc\u94dd\u590d\u5408\u6696\u6c14\u7247<\/strong>\uff1a\u5bfc\u70ed\u5feb\u3001\u8010\u8150\u8680\u3001\u5bff\u547d\u957f\uff0c\u914d\u5408\u94dd\u5851\u590d\u5408\u7ba1\u7edd\u6c27\u7cfb\u7edf\uff0c\u53ef\u964d\u4f4e\u540e\u671f\u7ef4\u62a4\u98ce\u9669\u3002<\/p>\n<p><!-- ===================== \u00a74 \u63a7\u5236 ===================== --><\/p>\n<h2 id=\"s4\">\u4e94\u3001\u7b2c\u56db\u8981\u7d20 \u00b7 \u63a7\u5236\uff1a\u4f9b\u70ed\u8981\"\u6309\u9700\"<\/h2>\n<h3>5.1 \u4e3a\u4ec0\u4e48\u6696\u6c14\u7247\u6bd4\u5730\u6696\u66f4\u9700\u8981\u8054\u52a8\u63a7\u5236<\/h3>\n<p>\u5730\u6696\u6709\u56de\u586b\u5c42\u84c4\u70ed\uff0c\u9505\u7089\u77ed\u65f6\u505c\u673a\u5bf9\u5ba4\u6e29\u5f71\u54cd\u6709\u9650\uff1b\u6696\u6c14\u7247\u662f<strong>\u5373\u70ed\u5f0f\u7cfb\u7edf<\/strong>\uff0c\u6ca1\u6709\u84c4\u70ed\u80fd\u529b\uff0c\u9505\u7089\u4e00\u505c\uff0c\u7247\u8eab\u6e29\u5ea6\u5f88\u5feb\u4e0b\u964d\u3002\u6ca1\u6709\u8054\u52a8\u63a7\u5236\u65f6\uff0c\u9505\u7089\u53ea\u6309\u51fa\u6c34\u6e29\u5ea6\u5de5\u4f5c\u2014\u2014\u6c34\u6e29\u5230\u4e86\u5c31\u505c\u3001\u964d\u4e86\u5c31\u70e7\uff0c\u4e0e\u623f\u95f4\u5b9e\u9645\u9700\u8981\u8131\u8282\uff0c\u5bb9\u6613\u51fa\u73b0\"\u5ba4\u6e29\u5df2\u591f\u5374\u8fd8\u5728\u70e7\"\u6216\"\u5ba4\u6e29\u672a\u591f\u5374\u5df2\u505c\u673a\"\u3002<\/p>\n<div class=\"spec-box\">\n<h3>\u3010\u4fee\u8ba2 3\u3011\u5b9a\u9891\u7089\u4e0d\u5f97\u76f4\u63a5\u914d\u81ea\u52a8\u6e29\u5305\u505a\u53d8\u6d41\u91cf\u63a7\u5236<\/h3>\n<p style=\"margin:6px 0\"><strong>\u666e\u901a\u7089\u662f\u5b9a\u9891\u7cfb\u7edf<\/strong>\uff1a\u71c3\u70e7\u5206\u9ad8 \/ \u4e2d \/ \u4f4e\u4e09\u6863\uff0c\u5185\u7f6e\u5faa\u73af\u6cf5\u4e3a\u5b9a\u901f\u6cf5\uff0c\u8bbe\u8ba1\u5de5\u51b5\u662f\"\u6d41\u91cf\u57fa\u672c\u6052\u5b9a\"\u3002<\/p>\n<p style=\"margin:6px 0\">\u800c\u81ea\u52a8\u6e29\u5305\uff08\u542b\u81ea\u529b\u5f0f\u6052\u6e29\u9600\u5934\u3001\u7535\u70ed\u6267\u884c\u5668\u7b49\uff09\u5c5e\u4e8e<strong>\u53d8\u6d41\u91cf\u672b\u7aef<\/strong>\u2014\u2014\u623f\u95f4\u6e29\u5ea6\u8fbe\u5230\u8bbe\u5b9a\u503c\u540e\uff0c\u9600\u95e8\u5173\u5c0f\u6216\u5173\u95ed\uff0c\u7cfb\u7edf\u6d41\u91cf\u968f\u4e4b\u4e0b\u964d\u3002\u4e8c\u8005\u76f4\u63a5\u7ec4\u5408\u4f1a\u51fa\u73b0\uff1a<\/p>\n<ul style=\"margin:6px 0\">\n<li>\u6d41\u7ecf\u9505\u7089\u6362\u70ed\u5668\u7684\u6c34\u91cf\u51cf\u5c11 \u2192 \u6362\u70ed\u6076\u5316\u3001\u5c40\u90e8\u8fc7\u70ed\uff0c\u6c34\u6e29\u6ce2\u52a8\u52a0\u5267\uff1b<\/li>\n<li>\u672b\u7aef\u5927\u91cf\u5173\u95ed\u65f6\uff0c\u9505\u7089\u4fa7\u6d41\u91cf\u4e0d\u8db3 \u2192 \u9891\u7e41\u542f\u505c\uff0c\u71c3\u6c14\u6d88\u8017\u4e0e\u8bbe\u5907\u6545\u969c\u7387\u540c\u6b65\u4e0a\u5347\uff1b<\/li>\n<li>\u5404\u652f\u8def\u4e92\u76f8\u62a2\u6c34 \u2192 \u672a\u5173\u95ed\u7684\u623f\u95f4\u53cd\u800c\u66f4\u4e0d\u70ed\uff0c\u6c34\u529b\u5931\u8861\u3002<\/li>\n<\/ul>\n<p style=\"margin:6px 0 0\"><strong>\u89c4\u8303\u6761\u6b3e\uff1a<\/strong>\u666e\u901a\u7089 + \u53d8\u6d41\u91cf\u6e29\u5305\u672b\u7aef\uff0c<strong>\u5fc5\u987b\u8bbe\u7f6e\u4e8c\u6b21\u7cfb\u7edf<\/strong>\uff0c\u7531\u4e8c\u6b21\u4fa7\u627f\u62c5\u53d8\u6d41\u91cf\uff0c\u9505\u7089\u4fa7\uff08\u4e00\u6b21\u4fa7\uff09\u4fdd\u6301\u6d41\u91cf\u7a33\u5b9a\u3002<\/p>\n<\/div>\n<div class=\"spec-box\">\n<h3>\u3010\u4fee\u8ba2 4\u3011\u6696\u6c14\u7247\u63a7\u5236\uff1a\u7531\u624b\u52a8\u9600\u5347\u7ea7\u4e3a\u6e29\u63a7\u5668<\/h3>\n<p style=\"margin:6px 0\">\u4f20\u7edf\u6696\u6c14\u7247\u5927\u91cf\u4f7f\u7528<strong>\u624b\u52a8\u9600<\/strong>\uff08\u624b\u8f6e\u8c03\u8282\uff09\uff0c\u5b9e\u9645\u4f7f\u7528\u4e2d\u95ee\u9898\u5f88\u76f4\u63a5\uff1a\u6696\u6c14\u7247\u591a\u88c5\u5728\u7a97\u4e0b\u3001\u6c99\u53d1\u80cc\u540e\u6216\u7a97\u5e18\u5185\u4fa7\uff0c\u5f2f\u8170\u4f38\u624b\u53bb\u62e7\u5f88\u4e0d\u65b9\u4fbf\uff0c\u591a\u6570\u5bb6\u5ead\u88c5\u4e0a\u540e\u5c31\u5e38\u5e74\u4e0d\u52a8\uff0c\u5206\u5ba4\u63a7\u6e29\u5f62\u540c\u865a\u8bbe\u3002<\/p>\n<p style=\"margin:6px 0\"><strong>\u6697\u57cb\u7cfb\u7edf\u5177\u5907\u505a\u6e29\u63a7\u5668\u7684\u6761\u4ef6<\/strong>\u2014\u2014\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\u4e00\u8def\u5bf9\u5e94\u4e00\u7ec4\u6696\u6c14\u7247\uff0c\u6b63\u597d\u53ef\u4ee5\u5728\u5206\u96c6\u6c34\u5668\u4fa7\u505a\u6267\u884c\u673a\u6784\uff0c\u628a\u63a7\u5236\u70b9\u4ece\"\u6696\u6c14\u7247\u8ddf\u524d\"\u79fb\u5230\"\u5899\u9762\u6e29\u63a7\u5668\"\uff1a<\/p>\n<table style=\"margin:10px 0\">\n<thead>\n<tr>\n<th style=\"width:22%\">\u65b9\u6848<\/th>\n<th style=\"width:34%\">\u6784\u6210<\/th>\n<th>\u7279\u70b9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u57fa\u7840<\/td>\n<td>\u6696\u6c14\u7247\u624b\u52a8\u9600 + \u9505\u7089\u6c34\u6e29\u63a7\u5236<\/td>\n<td>\u4ec5\u9650\u624b\u52a8\uff0c\u65e0\u8054\u52a8\uff0c\u64cd\u4f5c\u4e0d\u4fbf<\/td>\n<\/tr>\n<tr style=\"background:#fdf1ee\">\n<td><strong>\u63a8\u8350\uff08\u6697\u57cb\u6807\u914d\uff09<\/strong><\/td>\n<td><strong>\u623f\u95f4\u6e29\u63a7\u5668 + \u5206\u96c6\u6c34\u5668\u652f\u8def\u7535\u70ed\u6267\u884c\u5668 + \u9505\u7089\u8054\u52a8<\/strong><\/td>\n<td><strong>\u63a7\u5236\u70b9\u5728\u5899\u9762\uff0c\u64cd\u4f5c\u65b9\u4fbf\uff1b\u5206\u5ba4\u63a7\u6e29\uff0c\u5ba4\u6e29\u8fbe\u6807\u8054\u52a8\u9505\u7089\u505c\u673a<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u8fdb\u9636<\/td>\n<td>\u4e0a\u8ff0\u914d\u7f6e + \u4e8c\u6b21\u7cfb\u7edf\uff08\u53d8\u9891\u4e8c\u6b21\u6cf5\uff09<\/td>\n<td>\u652f\u6301\u53d8\u6d41\u91cf\u81ea\u52a8\u6e29\u5305\uff0c\u666e\u901a\u7089\u4e5f\u53ef\u5b89\u5168\u4f7f\u7528<\/td>\n<\/tr>\n<tr>\n<td>\u9ad8\u9636<\/td>\n<td>\u5168\u5c4b\u667a\u80fd\u6e29\u63a7\u7cfb\u7edf<\/td>\n<td>\u5206\u5ba4\u63a7\u6e29 + \u65f6\u6bb5\u7f16\u7a0b + \u8fdc\u7a0b\u63a7\u5236 + \u80fd\u8017\u7edf\u8ba1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:6px 0 0\"><strong>\u6e29\u63a7\u5668\u5b89\u88c5\u8981\u6c42\uff1a<\/strong>\u5b89\u88c5\u9ad8\u5ea6\u7ea6 1.3-1.5 m\uff0c\u4f4d\u4e8e\u623f\u95f4\u5185\u7a7a\u6c14\u6d41\u901a\u3001\u65e0\u9633\u5149\u76f4\u5c04\u3001\u4e0d\u88ab\u5bb6\u5177\u548c\u7a97\u5e18\u906e\u6321\u7684\u4f4d\u7f6e\uff1b\u907f\u514d\u88c5\u5728\u95e8\u53e3\u3001\u5916\u5899\u4fa7\u3001\u6696\u6c14\u7247\u6b63\u4e0a\u65b9\u6216\u7535\u5668\u6563\u70ed\u6e90\u9644\u8fd1\u3002<\/p>\n<\/div>\n<h3>5.2 \u8054\u52a8\u63a7\u5236\u7684\u8282\u80fd\u4e0e\u5206\u5ba4\u4f7f\u7528\u903b\u8f91<\/h3>\n<p>\u5206\u5ba4\u63a7\u5236\u7684\u6838\u5fc3\u539f\u5219\u662f\uff1a<strong>\u5e38\u5f00\u7684\u623f\u95f4\u4fdd\u6301\u8bbe\u5b9a\u6e29\u5ea6\uff0c\u4e0d\u7528\u7684\u623f\u95f4\u5173\u5230\u5e95\uff1b\u5ba4\u6e29\u8bbe\u5b9a\u4e0d\u5b9c\u8fc7\u9ad8\uff0820\u2103 \u5df2\u80fd\u6ee1\u8db3\u591a\u6570\u5bb6\u5ead\u7684\u8212\u9002\u9700\u6c42\uff09\uff1b\u914d\u5408\u8054\u52a8\u63a7\u5236\uff0c\u5ba4\u6e29\u8fbe\u6807\u5373\u505c\u7089\u3002<\/strong><\/p>\n<p>\u9700\u6ce8\u610f\uff0c\u82e5\u5f00\u542f\u7ec4\u6570\u8fc7\u5c11\uff08\u5982 100 \u33a1 \u53ea\u5f00 1 \u7ec4\uff09\uff0c\u672b\u7aef\u6563\u70ed\u9700\u6c42\u8fdc\u4f4e\u4e8e\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff0c\u540c\u6837\u4f1a\u5f15\u53d1\u9891\u7e41\u542f\u505c\uff0c\u6b64\u65f6\u5e94\u9002\u5f53\u589e\u52a0\u540c\u5f00\u7ec4\u6570\uff0c\u8ba9\u6563\u70ed\u603b\u91cf\u4e0e\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u5339\u914d\u3002<\/p>\n<p><!-- ===================== \u00a75 \u4e8c\u6b21\u7cfb\u7edf ===================== --><\/p>\n<h2 id=\"s5\">\u516d\u3001\u4e8c\u6b21\u7cfb\u7edf\u4e13\u7ae0\uff1a4 \u6761\u5f3a\u5236\u5224\u636e\u4e0e\u6807\u51c6\u914d\u7f6e<\/h2>\n<h3>6.1 \u4ec0\u4e48\u60c5\u51b5\u4e0b\u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"width:12%\">\u5224\u636e<\/th>\n<th style=\"width:44%\">\u89e6\u53d1\u6761\u4ef6<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u2460 \u70ed\u503c<\/strong><\/td>\n<td>\u7cfb\u7edf\u603b\u8bbe\u8ba1\u70ed\u8d1f\u8377 &gt; \u5185\u7f6e\u6cf5\u53ef\u643a\u5e26\u70ed\u503c\uff08\u9ad8\u6e29\u7ea6 16 kW \/ \u4f4e\u6e29\u7ea6 8 kW\uff09<\/td>\n<td>\u5185\u7f6e\u6cf5\u6d41\u91cf\u5c01\u9876\u4e8e\u7ea6 800 L\/h\uff0c\u8d85\u51fa\u90e8\u5206\"\u8fd0\u4e0d\u51fa\u53bb\"<\/td>\n<\/tr>\n<tr>\n<td><strong>\u2461 \u963b\u529b<\/strong><\/td>\n<td>\u6700\u957f\u73af\u8def\u603b\u963b\u529b\u8d85\u8fc7\u5185\u7f6e\u6cf5\u5269\u4f59\u626c\u7a0b<\/td>\n<td>\u6237\u578b\u5927\u3001\u4e3b\u7ba1\u957f\u3001\u652f\u8def\u591a\u65f6\u5e38\u89c1<\/td>\n<\/tr>\n<tr>\n<td><strong>\u2462 \u63a7\u5236<\/strong><\/td>\n<td>\u672b\u7aef\u91c7\u7528\u81ea\u52a8\u6e29\u5305 \/ \u7535\u70ed\u6267\u884c\u5668\u505a\u53d8\u6d41\u91cf\u63a7\u5236\uff0c\u4e14\u70ed\u6e90\u4e3a\u5b9a\u9891\u666e\u901a\u7089<\/td>\n<td>\u9700\u7531\u4e8c\u6b21\u4fa7\u5438\u6536\u6d41\u91cf\u53d8\u5316<\/td>\n<\/tr>\n<tr>\n<td><strong>\u2463 \u5de5\u51b5<\/strong><\/td>\n<td>\u4f4e\u6e29\u6696\u6c14\u7247\u7cfb\u7edf\uff08\u0394t \u2248 10\u2103\uff09\u603b\u8d1f\u8377 &gt; 8 kW<\/td>\n<td>\u4f4e\u6e29\u5de5\u51b5\u5bf9\u6d41\u91cf\u7684\u9700\u6c42\u7ea6\u4e3a\u9ad8\u6e29\u5de5\u51b5\u7684\u4e24\u500d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"chk\"><strong>\u5224\u5b9a\u89c4\u5219\uff1a<\/strong>\u56db\u6761\u4e2d<strong>\u4efb\u610f\u4e00\u6761\u6210\u7acb<\/strong>\uff0c\u5373\u5e94\u8bbe\u7f6e\u4e8c\u6b21\u7cfb\u7edf\u3002\u8bbe\u8ba1\u4ea4\u5e95\u65f6\u987b\u5728\u56fe\u7eb8\u4e0a\u6ce8\u660e\u89e6\u53d1\u7684\u5224\u636e\u7f16\u53f7\uff0c\u4fbf\u4e8e\u65bd\u5de5\u4e0e\u9a8c\u6536\u6838\u5bf9\u3002<\/div>\n<h3>6.2 \u4e8c\u6b21\u7cfb\u7edf\u7684\u6807\u51c6\u6784\u6210<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"width:20%\">\u7ec4\u6210<\/th>\n<th style=\"width:40%\">\u4e00\u6b21\u4fa7\uff08\u9505\u7089\u4fa7\uff09<\/th>\n<th>\u4e8c\u6b21\u4fa7\uff08\u672b\u7aef\u4fa7\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5faa\u73af\u52a8\u529b<\/td>\n<td>\u9505\u7089\u5185\u7f6e\u6cf5\uff08\u6216\u72ec\u7acb\u4e00\u6b21\u6cf5\uff09\uff0c<strong>\u6d41\u91cf\u7a33\u5b9a<\/strong><\/td>\n<td><strong>\u53d8\u9891\u5c4f\u853d\u6cf5<\/strong>\uff08\u6309\u4e8c\u6b21\u4fa7\u603b\u6d41\u91cf\u4e0e\u73af\u8def\u963b\u529b\u9009\u578b\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u8fde\u63a5\u90e8\u4ef6<\/td>\n<td colspan=\"2\"><strong>\u6c34\u529b\u5206\u538b\u5668\uff08\u8026\u5408\u7f50\uff09<\/strong>\uff1a\u5b9e\u73b0\u4e00\u3001\u4e8c\u6b21\u4fa7\u6c34\u529b\u89e3\u8026\uff0c\u517c\u6392\u6c14\u4e0e\u6392\u6c61<\/td>\n<\/tr>\n<tr>\n<td>\u5206\u8def\u90e8\u4ef6<\/td>\n<td>\u2014<\/td>\n<td>\u5206\u96c6\u6c34\u5668\uff08\u7ae0\u9c7c\u5f0f\uff09\uff0c\u5404\u652f\u8def\u914d\u7535\u70ed\u6267\u884c\u5668 \/ \u8c03\u8282\u9600<\/td>\n<\/tr>\n<tr>\n<td>\u63a7\u5236\u903b\u8f91<\/td>\n<td>\u9505\u7089\u6309\u81ea\u8eab\u6c34\u6e29 \/ \u5ba4\u6e29\u8054\u52a8\u8fd0\u884c\uff0c\u4e0d\u53d7\u672b\u7aef\u5f00\u5173\u5f71\u54cd<\/td>\n<td>\u623f\u95f4\u6e29\u63a7\u5668\u63a7\u5236\u6267\u884c\u5668\uff0c\u6d41\u91cf\u53ef\u53d8\uff1b\u53d8\u9891\u6cf5\u8ddf\u968f\u538b\u5dee\u81ea\u52a8\u8c03\u8282<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"warn-box\">\n<strong>\u4e3a\u4ec0\u4e48\u4e8c\u6b21\u6cf5\u8981\u9009\u53d8\u9891\uff1a<\/strong>\u4e8c\u6b21\u4fa7\u88c5\u4e86\u81ea\u52a8\u6e29\u5305\u540e\uff0c\u5404\u652f\u8def\u4f1a\u968f\u5ba4\u6e29\u9646\u7eed\u5173\u95ed\uff0c\u603b\u6d41\u91cf\u6301\u7eed\u53d8\u5316\u3002\u5b9a\u901f\u6cf5\u5728\u6d41\u91cf\u4e0b\u964d\u65f6\u626c\u7a0b\u62ac\u5347\u3001\u566a\u58f0\u4e0e\u80fd\u8017\u4e0a\u5347\uff0c\u8fd8\u4f1a\u5728\u5c11\u6570\u652f\u8def\u5f00\u542f\u65f6\u9020\u6210\u618b\u538b\uff1b<strong>\u53d8\u9891\u6cf5<\/strong>\u53ef\u6309\u8bbe\u5b9a\u538b\u5dee\u81ea\u52a8\u8c03\u8282\u8f6c\u901f\uff0c\u65e2\u652f\u6301\u53d8\u6d41\u91cf\u81ea\u52a8\u6e29\u5305\uff0c\u53c8\u5728\u5c0f\u8d1f\u8377\u65f6\u964d\u4f4e\u7535\u8017\u4e0e\u566a\u58f0\u3002<strong>\u5b9a\u901f\u6cf5\u4ec5\u9002\u7528\u4e8e\u4e0d\u505a\u53d8\u6d41\u91cf\u63a7\u5236\u7684\u573a\u5408\u3002<\/strong>\n<\/div>\n<h3>6.3 \u4e8c\u6b21\u7cfb\u7edf\u8c03\u8bd5\u8981\u70b9<\/h3>\n<ol>\n<li>\u4e00\u6b21\u4fa7\u4e0e\u4e8c\u6b21\u4fa7\u5206\u522b\u6392\u6c14\uff0c\u786e\u8ba4\u6c34\u529b\u5206\u538b\u5668\u5185\u65e0\u79ef\u6c14\uff1b<\/li>\n<li>\u8c03\u8282\u4e8c\u6b21\u6cf5\u6863\u4f4d \/ \u538b\u5dee\u8bbe\u5b9a\uff0c\u4f7f\u6700\u4e0d\u5229\u73af\u8def\u5728\u8bbe\u8ba1\u6d41\u91cf\u4e0b\u8fd0\u884c\uff1b<\/li>\n<li>\u9010\u8def\u8c03\u8282\u5206\u96c6\u6c34\u5668\u5404\u652f\u8def\uff0c\u4f7f\u5404\u56de\u8def\u7684\u4f9b\u56de\u6c34\u6e29\u5dee\u8d8b\u4e8e\u4e00\u81f4\uff1b<\/li>\n<li>\u9a8c\u8bc1\u8054\u52a8\uff1a\u5173\u95ed\u591a\u6570\u623f\u95f4\u6e29\u63a7\u5668\uff0c\u89c2\u5bdf\u9505\u7089\u662f\u5426\u7a33\u5b9a\u505c\u673a\u800c\u975e\u9891\u7e41\u542f\u505c\uff1b<\/li>\n<li>\u8bb0\u5f55\u5404\u652f\u8def\u6d41\u91cf \/ \u6e29\u5dee\u4e0e\u6cf5\u6863\u4f4d\uff0c\u4f5c\u4e3a\u7ae3\u5de5\u8d44\u6599\u4ea4\u4ed8\u4e1a\u4e3b\u3002<\/li>\n<\/ol>\n<h3>6.4 \u6697\u57cb\u6696\u6c14\u7247\u8f85\u6750\u914d\u7f6e\uff08\u7ae0\u9c7c\u5f0f \u00b7 \u542b\u4e8c\u6b21\u7cfb\u7edf\u4ef6\uff09<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u54c1\u7c7b<\/th>\n<th>\u54c1\u724c<\/th>\n<th>\u89c4\u683c<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u4e3b\u7ba1<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>F-PPR \u7ea4\u7ef4\u590d\u5408\u7ba1 De32\u00d74.4<\/td>\n<td>\u70ed\u6c34\u4e3b\u7ba1<\/td>\n<\/tr>\n<tr>\n<td>\u652f\u7ba1<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>\u94dd\u5851\u590d\u5408\u7ba1 De16\u00d72.2<\/td>\n<td>\u5206\u96c6\u6c34\u5668\u81f3\u6696\u6c14\u7247\uff0c\u7edd\u6c27<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u7ba1\uff08\u4e3b\u7ba1\uff09<\/td>\n<td>\u4e3d\u9a6c \/ \u534e\u7f8e<\/td>\n<td>\u00d832 \u6a61\u5851\u4fdd\u6e29\u7ba1<\/td>\n<td>\u51cf\u5c11\u8f93\u9001\u70ed\u635f\u5931<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29\u7ba1\uff08\u652f\u7ba1\uff09<\/td>\n<td>\u4e3d\u9a6c \/ \u534e\u7f8e<\/td>\n<td>\u00d816 \u6a61\u5851\u4fdd\u6e29\u7ba1<\/td>\n<td>\u51cf\u5c11\u8f93\u9001\u70ed\u635f\u5931<\/td>\n<\/tr>\n<tr>\n<td>\u5206\u6c34\u7bb1<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>500 mm<\/td>\n<td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u5206\u96c6\u6c34\u5668<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>DN25\uff08\u94dc\u8d28\uff09<\/td>\n<td>\u5206\u8def\u63a7\u5236\u4e0e\u5e73\u8861\u8c03\u8282<\/td>\n<\/tr>\n<tr>\n<td>\u89d2\u5f0f\u7403\u9600<\/td>\n<td>\u4f1f\u661f<\/td>\n<td>PPR DN25<\/td>\n<td>\u901a\u65ad\u5206\u96c6\u6c34\u5668\u6c34\u6d41\uff0c\u4fbf\u4e8e\u68c0\u4fee<\/td>\n<\/tr>\n<tr>\n<td>\u672b\u7aef\u5c3e\u4ef6<\/td>\n<td>\u56fd\u4ea7\u4f18\u8d28<\/td>\n<td>DN15<\/td>\n<td>\u6392\u6c14\u9600 + \u6cc4\u6c34\u9600 + \u538b\u529b\u8868<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u914d\u5668<\/td>\n<td>\u5a01\u5c14\u9f99<\/td>\n<td>16 mm<\/td>\n<td>\u7ba1\u4ef6\u63a5\u5934<\/td>\n<\/tr>\n<tr>\n<td>\u5f2f\u7ba1\u5957<\/td>\n<td>\u8ba2\u8d2d<\/td>\n<td>\u00d820<\/td>\n<td>\u5206\u96c6\u6c34\u5668\u5f2f\u7ba1\u5904\u4fdd\u62a4<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u529b\u5206\u538b\u5668<\/td>\n<td>\u5a01\u5c14\u9f99<\/td>\n<td>DN25<\/td>\n<td>\u4e8c\u6b21\u7cfb\u7edf\u914d\u5957\uff0c\u4e00\u4e8c\u6b21\u4fa7\u89e3\u8026<\/td>\n<\/tr>\n<tr>\n<td>\u5faa\u73af\u6c34\u6cf5<\/td>\n<td>\u5fb7\u56fd\u5a01\u4e50<\/td>\n<td>Wilo-RS25\/8\uff08\u5b9a\u901f\uff09<br \/>\u53d8\u6d41\u91cf\u573a\u5408\u914d\u53d8\u9891\u578b<\/td>\n<td>\u4e8c\u6b21\u7cfb\u7edf\u914d\u5957\uff1b\u53d8\u6d41\u91cf\u63a7\u5236\u4f18\u5148\u9009\u53d8\u9891\u6cf5<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6ce5\u7802\u6d46<\/td>\n<td>\u56fd\u4ea7\u4f18\u8d28<\/td>\n<td>\/<\/td>\n<td>\u5f00\u69fd\u540e\u8986\u76d6\u4fee\u8865<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tiny\">\u8f85\u6750\u54c1\u724c\u4e0e\u89c4\u683c\u4ee5\u5f53\u671f\u5b9e\u9645\u4f9b\u8d27\u4e0e\u5408\u540c\u7ea6\u5b9a\u4e3a\u51c6\uff0c\u672c\u8868\u4e3a\u5e38\u89c4\u914d\u7f6e\u53c2\u8003\u3002<\/p>\n<p><!-- ===================== \u00a76 \u516b\u6b65\u6cd5 ===================== --><\/p>\n<h2 id=\"s6\">\u4e03\u3001\u8bbe\u8ba1\u516b\u6b65\u6cd5\u4e0e\u9a8c\u6536\u6e05\u5355<\/h2>\n<p>\u4ee5\u4e0b\u6b65\u9aa4\u65e2\u662f\u8bbe\u8ba1\u6d41\u7a0b\uff0c\u4e5f\u662f\u4ea4\u5e95\u4e0e\u9a8c\u6536\u4f9d\u636e\uff0c\u6bcf\u4e00\u6b65\u90fd\u914d\u5957\u53ef\u91cf\u5316\u7684\u68c0\u67e5\u70b9\u3002<\/p>\n<div class=\"howto-step-wrap\">\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 1 \u00b7 \u73b0\u573a\u52d8\u6d4b\u4e0e\u70ed\u8d1f\u8377\u8ba1\u7b97<\/h3>\n<p>\u52d8\u6d4b\u671d\u5411\u3001\u7a97\u5899\u6bd4\u3001\u4fdd\u6e29\u60c5\u51b5\u3001\u5c42\u9ad8\u4e0e\u9876 \/ \u5e95 \/ \u8fb9\u6237\u4f4d\u7f6e\uff0c\u8ba1\u7b97\u5404\u623f\u95f4\u70ed\u8d1f\u8377\uff08\u6210\u90fd\u4f4f\u5b85\u53c2\u8003\u533a\u95f4 100-140 W\/\u33a1\uff09\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u51fa\u5177\u5206\u623f\u95f4\u70ed\u8d1f\u8377\u8868\uff0c\u5408\u8ba1\u603b\u8d1f\u8377\u660e\u786e\uff0c\u4f5c\u4e3a\u540e\u7eed\u7ba1\u5f84\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u5224\u5b9a\u7684\u8f93\u5165\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 2 \u00b7 \u7089\u578b\u9009\u62e9\u4e0e\u5224\u5e9f\u5e74\u9650\u6838\u67e5<\/h3>\n<p>\u6309\u4f9b\u6c34\u6e29\u5ea6\u786e\u5b9a\u9ad8\u6e29 \/ \u4f4e\u6e29\u8def\u7ebf\uff0c\u9009\u62e9\u666e\u901a\u7089\u6216\u51b7\u51dd\u7089\uff1b\u6838\u67e5\u5728\u5f79\u9505\u7089\u7684\u542f\u7528\u65e5\u671f\uff0c\u5224\u5e9f\u5e74\u9650\u7edf\u4e00\u6309 <strong>8 \u5e74<\/strong> \u6267\u884c\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u65b9\u6848\u4e66\u4e0e\u62a5\u4ef7\u5355\u4e2d\u7684\u8bbe\u5907\u4f7f\u7528\u5e74\u9650\u8868\u8ff0\u7edf\u4e00\u4e3a 8 \u5e74\uff1b\u8d85\u8fc7\u5224\u5e9f\u5e74\u9650\u7684\u8bbe\u5907\u5217\u5165\u66f4\u6362\u8bc4\u4f30\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 3 \u00b7 \u5185\u7f6e\u6cf5\u70ed\u503c\u6838\u7b97\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u5224\u5b9a<\/h3>\n<p>\u6309 Q \u2248 q \u00d7 \u0394t \u00d7 1.0 \u6838\u7b97\uff08q \u53d6\u7ea6 0.8 m\u00b3\/h\uff09\uff1a\u9ad8\u6e29\u5de5\u51b5\u7ea6 16 kW\uff0c\u4f4e\u6e29\u5de5\u51b5\u7ea6 8 kW\uff1b\u5bf9\u7167\u56db\u6761\u5224\u636e\u9010\u6761\u6838\u5bf9\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u56fe\u7eb8\u4e0a\u6807\u6ce8\u89e6\u53d1\u7684\u5224\u636e\u7f16\u53f7\uff1b\u9700\u505a\u4e8c\u6b21\u7cfb\u7edf\u7684\uff0c\u660e\u786e\u6c34\u529b\u5206\u538b\u5668\u89c4\u683c\u4e0e\u4e8c\u6b21\u6cf5\u9009\u578b\uff08\u662f\u5426\u53d8\u9891\uff09\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 4 \u00b7 \u4e3b\u7ba1\u7ba1\u5f84\u4e0e\u8d70\u5411\u8bbe\u8ba1<\/h3>\n<p>\u4e3b\u7ba1\u8d77\u6b65 De32\uff0c\u6309\u70ed\u8d1f\u8377\u4e0e\u6d41\u91cf\u590d\u6838\uff1b\u5f2f\u5934\u91c7\u7528\u5f2f\u7ba1\u5668\u5f2f\u5236\u5927\u5f27\u5f2f\uff0c\u5f2f\u66f2\u534a\u5f84\u4e0d\u5c0f\u4e8e 6 \u500d\u7ba1\u5916\u5f84\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u4e3b\u7ba1\u89c4\u683c\u3001\u8d70\u5411\u3001\u5761\u5ea6\u4e0e\u6392\u6c14\u70b9\u6807\u6ce8\u5b8c\u6574\uff1b\u73b0\u573a\u6838\u5bf9\u65e0\u76f4\u89d2\u5f2f\u5934\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 5 \u00b7 \u5206\u96c6\u6c34\u5668\u4e0e\u5206\u6c34\u7bb1\u5b9a\u4f4d<\/h3>\n<p>\u6309\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\u786e\u5b9a\u56de\u8def\u6570\u91cf\u4e0e\u5206\u6c34\u7bb1\u4f4d\u7f6e\uff0c\u7bb1\u4f53\u9700\u68c0\u4fee\u53ef\u8fbe\uff0c\u907f\u5f00\u56fa\u5b9a\u5bb6\u5177\u4e0e\u6e7f\u533a\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u56de\u8def\u6570\u91cf\u4e0e\u6696\u6c14\u7247\u7ec4\u6570\u4e00\u81f4\uff1b\u7bb1\u4f53\u5b89\u88c5\u7262\u56fa\uff0c\u68c0\u4fee\u95e8\u5f00\u542f\u4e0d\u53d7\u963b\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 6 \u00b7 \u652f\u7ba1\u5e03\u7ba1\uff08\u7edd\u6c27 + \u65e0\u63a5\u5934\uff09<\/h3>\n<p>\u652f\u7ba1\u91c7\u7528\u94dd\u5851\u590d\u5408\u7ba1 De16\u00d72.2\uff0c\u4ece\u5206\u96c6\u6c34\u5668\u5230\u6696\u6c14\u7247\u4e00\u7ba1\u5230\u5e95\uff0c\u4e2d\u95f4\u65e0\u63a5\u5934\uff1b\u4e3b\u652f\u7ba1\u6309\u89c4\u683c\u5305\u8986\u6a61\u5851\u4fdd\u6e29\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u5168\u6570\u76ee\u89c6\u68c0\u67e5\uff0c\u57cb\u5730\u6bb5\u65e0\u63a5\u5934\uff1b\u4fdd\u6e29\u8fde\u7eed\u65e0\u9057\u6f0f\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 7 \u00b7 \u6696\u6c14\u7247\u9884\u7559\u4e0e\u672b\u7aef\u5b9a\u4f4d<\/h3>\n<p>\u4f18\u5148\u7a97\u4e0b \/ \u5916\u5899\u5e03\u7f6e\uff1b\u9884\u7559\u7ba1\u53e3\u4f4d\u7f6e\u987b\u8ba1\u5165\u5899\u9762\u3001\u5730\u9762\u5b8c\u6210\u9762\u539a\u5ea6\uff1b\u6838\u5b9e\u6302\u7247\u652f\u67b6\u627f\u91cd\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u4e2d\u5fc3\u8ddd\u3001\u51fa\u5899\u957f\u5ea6\u4e0e\u5b8c\u6210\u9762\u57fa\u51c6\u590d\u6838\u65e0\u8bef\uff0c\u4e0e\u5bb6\u5177\u3001\u63d2\u5ea7\u3001\u7a97\u5e18\u76d2\u65e0\u51b2\u7a81\u3002<\/div>\n<\/div>\n<div class=\"step-item\">\n<h3>\u6b65\u9aa4 8 \u00b7 \u6253\u538b\u3001\u56de\u586b\u4e0e\u7cfb\u7edf\u8c03\u8bd5<\/h3>\n<p>\u56de\u586b\u5c01\u69fd\u524d\u6253\u538b\u81f3 0.6-0.8 MPa\uff0c\u4fdd\u538b 24 \u5c0f\u65f6\u65e0\u964d\u538b\uff1b\u7cfb\u7edf\u5b8c\u5de5\u540e\u518d\u505a\u4e00\u6b21\u8bd5\u538b\u4e0e\u8c03\u8bd5\u3002<\/p>\n<div class=\"chk\">\u2705 \u9a8c\u6536\u8981\u70b9\uff1a\u4e24\u6b21\u6253\u538b\u8bb0\u5f55\u7559\u5b58\uff08\u542b\u538b\u529b\u503c\u4e0e\u65f6\u957f\uff09\uff1b\u8c03\u8bd5\u65f6\u9010\u8def\u505a\u6c34\u529b\u5e73\u8861\uff0c\u5404\u652f\u8def\u6e29\u5dee\u8d8b\u4e8e\u4e00\u81f4\uff1b\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u8054\u52a8\u529f\u80fd\u5b9e\u6d4b\u901a\u8fc7\u3002<\/div>\n<\/div>\n<\/div>\n<p><!-- ===================== \u00a77 \u901f\u67e5\u8868 ===================== --><\/p>\n<h2 id=\"s7\">\u516b\u3001\u6697\u57cb\u6696\u6c14\u7247\u8bbe\u8ba1\u89c4\u8303\u901f\u67e5\u603b\u8868<\/h2>\n<table>\n<thead>\n<tr>\n<th style=\"width:18%\">\u9879\u76ee<\/th>\n<th style=\"width:30%\">\u89c4\u8303\u6807\u51c6<\/th>\n<th style=\"width:26%\">\u5224\u636e \/ \u4f9d\u636e<\/th>\n<th>\u4e0d\u8fbe\u6807\u7684\u540e\u679c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u58c1\u6302\u7089\u5224\u5e9f\u5e74\u9650<\/td>\n<td>\u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089<strong>\u7edf\u4e00 8 \u5e74<\/strong>\uff08\u81ea\u552e\u51fa\u65e5\u8d77\uff09<\/td>\n<td>\u5bb6\u7528\u71c3\u6c14\u71c3\u70e7\u5668\u5177\u5b89\u5168\u7ba1\u7406\u76f8\u5173\u8981\u6c42<\/td>\n<td>\u8d85\u671f\u4f7f\u7528\u5b58\u5728\u5b89\u5168\u4e0e\u6548\u7387\u98ce\u9669<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u7f6e\u6cf5\u53ef\u643a\u5e26\u70ed\u503c<\/td>\n<td>\u9ad8\u6e29 \u0394t=20\u2103 \u7ea6 <strong>16 kW<\/strong>\uff1b\u4f4e\u6e29 \u0394t=10\u2103 \u7ea6 <strong>8 kW<\/strong><\/td>\n<td>Q \u2248 q \u00d7 \u0394t \u00d7 1.0\uff0cq \u2248 0.8 m\u00b3\/h<\/td>\n<td>\u8d85\u51fa\u5373\u8fd1\u70ed\u8fdc\u51b7\u3001\u5347\u6e29\u6162<\/td>\n<\/tr>\n<tr>\n<td>\u4e8c\u6b21\u7cfb\u7edf<\/td>\n<td>\u56db\u6761\u5224\u636e\u4efb\u610f\u4e00\u6761\u6210\u7acb\u5373\u8bbe\u7f6e<\/td>\n<td>\u70ed\u503c \/ \u963b\u529b \/ \u53d8\u6d41\u91cf\u63a7\u5236 \/ \u4f4e\u6e29\u5de5\u51b5<\/td>\n<td>\u672b\u7aef\u4e0d\u70ed\u3001\u9505\u7089\u9891\u7e41\u542f\u505c<\/td>\n<\/tr>\n<tr>\n<td>\u4e8c\u6b21\u6cf5\u578b\u5f0f<\/td>\n<td>\u53d8\u6d41\u91cf\u63a7\u5236<strong>\u5fc5\u987b\u914d\u53d8\u9891\u6cf5<\/strong><\/td>\n<td>\u672b\u7aef\u6e29\u5305\u5173\u65ad\u65f6\u6d41\u91cf\u6301\u7eed\u53d8\u5316<\/td>\n<td>\u618b\u538b\u3001\u566a\u58f0\u3001\u80fd\u8017\u4e0a\u5347<\/td>\n<\/tr>\n<tr>\n<td>\u666e\u901a\u7089 + \u6e29\u5305<\/td>\n<td>\u4e0d\u5f97\u76f4\u63a5\u7ec4\u5408\uff0c\u987b\u7ecf\u4e8c\u6b21\u7cfb\u7edf\u9694\u79bb<\/td>\n<td>\u666e\u901a\u7089\u4e3a\u5b9a\u9891 + \u5b9a\u901f\u6cf5<\/td>\n<td>\u6362\u70ed\u6076\u5316\u3001\u542f\u505c\u9891\u7e41<\/td>\n<\/tr>\n<tr>\n<td>\u6696\u6c14\u7247\u63a7\u5236\u65b9\u5f0f<\/td>\n<td>\u4f18\u5148\u623f\u95f4\u6e29\u63a7\u5668 + \u5206\u96c6\u6c34\u5668\u7535\u70ed\u6267\u884c\u5668<\/td>\n<td>\u7ae0\u9c7c\u5f0f\u4e00\u8def\u4e00\u7ec4\uff0c\u63a7\u5236\u70b9\u53ef\u79fb\u81f3\u5899\u9762<\/td>\n<td>\u624b\u52a8\u9600\u64cd\u4f5c\u4e0d\u4fbf\uff0c\u5206\u5ba4\u63a7\u6e29\u5931\u6548<\/td>\n<\/tr>\n<tr>\n<td>\u5e03\u7ba1\u65b9\u5f0f<\/td>\n<td>\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668\uff0c\u5404\u56de\u8def\u72ec\u7acb\u4f9b\u56de<\/td>\n<td>\u6697\u57cb\u53ef\u68c0\u4fee\u6027\u8981\u6c42<\/td>\n<td>\u65e0\u6cd5\u5355\u8def\u68c0\u4fee\u4e0e\u8c03\u8282<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u7ba1\u89c4\u683c<\/td>\n<td>\u8d77\u6b65 <strong>De32<\/strong>\uff08\u5185\u5f84 26 mm\uff09<\/td>\n<td>10\u2103 \u6e29\u5dee\u53ef\u643a\u5e26\u7ea6 11.6 kW<\/td>\n<td>De25 \u4ec5\u7ea6 5.8 kW\uff0c\u6700\u51b7\u65f6\u6bb5\u4e0d\u8db3<\/td>\n<\/tr>\n<tr>\n<td>\u5f2f\u5934<\/td>\n<td>\u5927\u5f27\u5f2f\uff0c\u5f2f\u66f2\u534a\u5f84 \u22656 \u500d\u7ba1\u5916\u5f84<\/td>\n<td>\u94dd\u5851\u590d\u5408\u7ba1\u5f2f\u66f2\u534a\u5f84\u8981\u6c42<\/td>\n<td>\u5c40\u90e8\u963b\u529b\u6210\u500d\u4e0a\u5347<\/td>\n<\/tr>\n<tr>\n<td>\u652f\u7ba1\u7ba1\u6750<\/td>\n<td>\u94dd\u5851\u590d\u5408\u7ba1 De16\u00d72.2<\/td>\n<td>\u4e2d\u95f4\u94dd\u5c42\u5b8c\u5168\u7edd\u6c27<\/td>\n<td>\u94a2\u5236\u6696\u6c14\u7247\u6c27\u5316\u8150\u8680\u3001\u5835\u585e<\/td>\n<\/tr>\n<tr>\n<td>\u57cb\u5730\u63a5\u5934<\/td>\n<td>\u4e0d\u5e94\u6709\u63a5\u5934\uff0c\u635f\u574f\u5e94\u6574\u6839\u66f4\u6362<\/td>\n<td>\u586b\u5145\u5c42\u5185\u8f93\u914d\u7ba1\u65bd\u5de5\u8981\u6c42<\/td>\n<td>\u6e17\u6f0f\u9700\u7838\u5730\u7ef4\u4fee<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29<\/td>\n<td>\u4e3b\u7ba1 \u226520 mm\u3001\u652f\u7ba1 \u226510 mm \u6a61\u5851\u4fdd\u6e29<\/td>\n<td>\u8f93\u9001\u8fc7\u7a0b\u70ed\u635f\u5931\u63a7\u5236<\/td>\n<td>\u70ed\u91cf\u5411\u697c\u677f\u6563\u5931<\/td>\n<\/tr>\n<tr>\n<td>\u6253\u538b<\/td>\n<td>0.6-0.8 MPa \u4fdd\u538b 24 h \u65e0\u964d\u538b\uff0c\u5171\u4e24\u6b21<\/td>\n<td>\u9690\u853d\u524d + \u5b8c\u5de5\u540e<\/td>\n<td>\u9690\u6027\u6e17\u6f0f\u96be\u53d1\u73b0<\/td>\n<\/tr>\n<tr>\n<td>\u6696\u6c14\u7247\u4f4d\u7f6e<\/td>\n<td>\u7a97\u4e0b\u6216\u5916\u5899\u4f18\u5148<\/td>\n<td>\u70ed\u6c14\u6d41\u5f62\u6210\u6c14\u5e18<\/td>\n<td>\u51b7\u7a7a\u6c14\u76f4\u63a5\u4fb5\u5165\uff0c\u4f53\u611f\u5dee<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- ===================== FAQ ===================== --><\/p>\n<h2 id=\"faq\">\u4e5d\u3001\u5e38\u89c1\u95ee\u9898 FAQ<\/h2>\n<div class=\"faq-wrap\">\n<div class=\"faq-item\">\n<h3>Q1\uff1a\u58c1\u6302\u7089\u5230\u5e95\u80fd\u7528\u591a\u5c11\u5e74\uff1f\u51b7\u51dd\u7089\u662f\u4e0d\u662f\u66f4\u8010\u7528\uff1f<\/h3>\n<div class=\"faq-ans\">\u6309\u56fd\u5bb6\u5173\u4e8e\u5bb6\u7528\u71c3\u6c14\u71c3\u70e7\u5668\u5177\u5b89\u5168\u7ba1\u7406\u7684\u76f8\u5173\u8981\u6c42\uff0c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u7684\u5224\u5e9f\u5e74\u9650\u4e3a <strong>8 \u5e74<\/strong>\uff0c\u81ea\u552e\u51fa\u4e4b\u65e5\u8d77\u8ba1\u7b97\uff0c<strong>\u666e\u901a\u7089\u4e0e\u51b7\u51dd\u7089\u6267\u884c\u540c\u4e00\u6807\u51c6<\/strong>\u3002\u51b7\u51dd\u7089\u7684\u4f18\u52bf\u5728\u4e8e\u4f4e\u6e29\u5de5\u51b5\u4e0b\u7684\u70ed\u6548\u7387\u4e0e\u529f\u7387\u8c03\u8282\u8303\u56f4\uff0c\u4e0d\u5728\u5224\u5e9f\u5e74\u9650\u3002\u65b9\u6848\u4e0e\u62a5\u4ef7\u4e2d\u6d89\u53ca\u4f7f\u7528\u5e74\u9650\u7684\u8868\u8ff0\uff0c\u7edf\u4e00\u6309 8 \u5e74\u4e66\u5199\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q2\uff1a\u58c1\u6302\u7089\u81ea\u5e26\u6c34\u6cf5\uff0c\u4e3a\u4ec0\u4e48\u8fd8\u8981\u505a\u4e8c\u6b21\u7cfb\u7edf\uff1f<\/h3>\n<div class=\"faq-ans\">\u56e0\u4e3a\u5185\u7f6e\u6cf5\u7684\u6d41\u91cf\u6709\u9650\uff0c\u901a\u5e38\u53ea\u6709\u7ea6 <strong>800 L\/h<\/strong>\u3002\u6309 Q \u2248 q \u00d7 \u0394t \u00d7 1.0 \u6838\u7b97\uff1a\u9ad8\u6e29\u5de5\u51b5\uff08\u0394t=20\u2103\uff09\u7ea6\u80fd\u643a\u5e26 16 kW \u70ed\u503c\uff0c\u4f4e\u6e29\u5de5\u51b5\uff08\u0394t=10\u2103\uff09\u53ea\u6709\u7ea6 8 kW\u3002\u5f53\u7cfb\u7edf\u603b\u70ed\u8d1f\u8377\u8d85\u8fc7\u8fd9\u4e2a\u6570\uff0c\u6216\u8005\u73af\u8def\u963b\u529b\u5403\u6389\u6cf5\u7684\u626c\u7a0b\u3001\u672b\u7aef\u8fd8\u8981\u505a\u53d8\u6d41\u91cf\u63a7\u5236\u65f6\uff0c\u5c31\u5fc5\u987b\u7528\u6c34\u529b\u5206\u538b\u5668 + \u4e8c\u6b21\u6cf5\u628a\"\u9505\u7089\u4fa7\"\u548c\"\u672b\u7aef\u4fa7\"\u5206\u5f00\uff0c\u8ba9\u4e24\u4fa7\u5404\u81ea\u6309\u9700\u8981\u8fd0\u884c\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q3\uff1a\u600e\u4e48\u5224\u65ad\u6211\u5bb6\u8981\u4e0d\u8981\u505a\u4e8c\u6b21\u7cfb\u7edf\uff1f<\/h3>\n<div class=\"faq-ans\">\u770b\u56db\u6761\u5224\u636e\uff0c\u4efb\u610f\u4e00\u6761\u6210\u7acb\u5c31\u5efa\u8bae\u505a\uff1a\u2460 \u7cfb\u7edf\u603b\u8d1f\u8377 &gt; 16 kW\uff08\u9ad8\u6e29\u6696\u6c14\u7247\uff09\u6216 &gt; 8 kW\uff08\u4f4e\u6e29\u6696\u6c14\u7247\uff09\uff1b\u2461 \u6700\u957f\u73af\u8def\u963b\u529b\u8d85\u8fc7\u5185\u7f6e\u6cf5\u5269\u4f59\u626c\u7a0b\uff1b\u2462 \u672b\u7aef\u8981\u7528\u81ea\u52a8\u6e29\u5305\u505a\u53d8\u6d41\u91cf\u63a7\u5236\uff0c\u800c\u9505\u7089\u662f\u5b9a\u9891\u666e\u901a\u7089\uff1b\u2463 \u4f4e\u6e29\u6696\u6c14\u7247\u7cfb\u7edf\u603b\u8d1f\u8377\u8d85\u8fc7 8 kW\u3002\u4ee5\u6210\u90fd 120 \u33a1 \u4f4f\u5b85\u4e3a\u4f8b\uff0c\u70ed\u8d1f\u8377\u6309 140 W\/\u33a1 \u8ba1\u7b97\u7ea6 16.8 kW\uff0c\u5df2\u7ecf\u8d85\u8fc7\u5185\u7f6e\u6cf5\u80fd\u529b\uff0c\u9700\u8981\u8bbe\u7f6e\u4e8c\u6b21\u7cfb\u7edf\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q4\uff1a\u666e\u901a\u7089\u80fd\u4e0d\u80fd\u914d\u81ea\u52a8\u6e29\u63a7\u9600\uff08\u6e29\u5305\uff09\uff1f<\/h3>\n<div class=\"faq-ans\">\u4e0d\u5efa\u8bae\u76f4\u63a5\u914d\u3002\u666e\u901a\u7089\u662f<strong>\u5b9a\u9891\u7cfb\u7edf<\/strong>\uff0c\u5185\u7f6e\u6cf5\u4e3a\u5b9a\u901f\u6cf5\uff0c\u8bbe\u8ba1\u524d\u63d0\u662f\u6d41\u91cf\u57fa\u672c\u6052\u5b9a\uff1b\u800c\u81ea\u52a8\u6e29\u5305\u4f1a\u968f\u5ba4\u6e29\u5173\u5c0f\u9600\u95e8\uff0c\u5c5e\u4e8e\u53d8\u6d41\u91cf\u672b\u7aef\u3002\u4e24\u8005\u76f4\u63a5\u7ec4\u5408\u4f1a\u5bfc\u81f4\u6d41\u7ecf\u9505\u7089\u7684\u6c34\u91cf\u4e0d\u8db3\u3001\u6362\u70ed\u6076\u5316\u3001\u9891\u7e41\u542f\u505c\u3002<strong>\u6b63\u786e\u505a\u6cd5\u662f\u5148\u505a\u4e8c\u6b21\u7cfb\u7edf<\/strong>\uff1a\u4e00\u6b21\u4fa7\uff08\u9505\u7089\u4fa7\uff09\u6d41\u91cf\u4fdd\u6301\u7a33\u5b9a\uff0c\u4e8c\u6b21\u4fa7\u914d<strong>\u53d8\u9891\u6cf5<\/strong>\u627f\u62c5\u672b\u7aef\u53d8\u6d41\u91cf\uff0c\u8fd9\u6837\u666e\u901a\u7089\u4e5f\u80fd\u5b89\u5168\u4f7f\u7528\u81ea\u52a8\u6e29\u5305\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q5\uff1a\u6697\u57cb\u6696\u6c14\u7247\u600e\u4e48\u63a7\u5236\uff0c\u8fd8\u8981\u4e0d\u8981\u88c5\u624b\u52a8\u9600\uff1f<\/h3>\n<div class=\"faq-ans\">\u5efa\u8bae\u628a\u63a7\u5236\u70b9\u4ece\u6696\u6c14\u7247\u79fb\u5230\u5899\u9762\u3002\u6697\u57cb\u91c7\u7528\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\uff0c\u4e00\u8def\u5bf9\u5e94\u4e00\u7ec4\u6696\u6c14\u7247\uff0c\u53ef\u4ee5\u5728\u5206\u96c6\u6c34\u5668\u652f\u8def\u88c5<strong>\u7535\u70ed\u6267\u884c\u5668<\/strong>\uff0c\u623f\u95f4\u91cc\u88c5<strong>\u6e29\u63a7\u5668<\/strong>\uff0c\u5728\u5899\u4e0a\u6309\u4e00\u4e0b\u5c31\u80fd\u8c03\u6e29\uff0c\u8fd8\u80fd\u8bbe\u5b9a\u6e29\u5ea6\u81ea\u52a8\u505c\u7089\u3002\u76f8\u6bd4\u88c5\u5728\u7a97\u4e0b\u3001\u6c99\u53d1\u80cc\u540e\u7684\u624b\u52a8\u9600\uff0c\u65e5\u5e38\u4f7f\u7528\u7387\u9ad8\u5f97\u591a\uff0c\u5206\u5ba4\u63a7\u6e29\u624d\u771f\u6b63\u843d\u5f97\u4e0b\u53bb\u3002\u68c0\u4fee\u89d2\u5ea6\uff0c\u6696\u6c14\u7247\u4fa7\u4ecd\u4fdd\u7559\u53ef\u5173\u65ad\u9600\u95e8\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q6\uff1a\u6697\u57cb\u6696\u6c14\u7247\u548c\u660e\u88c5\u6696\u6c14\u7247\uff0c\u6548\u679c\u5dee\u522b\u5927\u5417\uff1f<\/h3>\n<div class=\"faq-ans\">\u4e24\u8005\u90fd\u80fd\u8fbe\u5230\u8212\u9002\u7684\u91c7\u6696\u6548\u679c\uff0c\u5dee\u522b\u5728\u65bd\u5de5\u65f6\u673a\u4e0e\u7ba1\u8def\u5f62\u5f0f\u3002\u6697\u57cb\u9700\u8981\u5728\u88c5\u4fee\u9636\u6bb5\u5f00\u69fd\u5e03\u7ba1\uff0c\u7ba1\u9053\u57cb\u5165\u5730\u9762\uff0c\u7f8e\u89c2\u5ea6\u9ad8\uff0c\u4e14\u91c7\u7528\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668\uff0c\u6c34\u529b\u5e73\u8861\u66f4\u597d\u63a7\u5236\uff0c\u9002\u5408\u65b0\u623f\u88c5\u4fee\uff1b\u660e\u88c5\u9002\u5408\u5df2\u88c5\u4fee\u623f\uff0c\u6cbf\u8e22\u811a\u7ebf\u6216\u9876\u9762\u8d70\u7ba1\uff0c\u5de5\u671f\u77ed\u3002\u53ef\u53c2\u8003\u660e\u88c5\u6696\u6c14\u7247\u65b9\u6848\u505a\u5bf9\u6bd4\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q7\uff1a\u6697\u57cb\u7ba1\u8def\u80fd\u7528\u591a\u4e45\uff1f\u4f1a\u4e0d\u4f1a\u6f0f\uff1f<\/h3>\n<div class=\"faq-ans\">\u5728\u7ba1\u6750\u4e0e\u5de5\u827a\u8fbe\u6807\u7684\u524d\u63d0\u4e0b\uff08\u652f\u7ba1\u7528\u94dd\u5851\u590d\u5408\u7ba1\u7edd\u6c27\u3001\u57cb\u5730\u65e0\u63a5\u5934\u3001\u4e24\u6b21\u6253\u538b\u5408\u683c\uff09\uff0c\u7ba1\u8def\u672c\u8eab\u7684\u4f7f\u7528\u5e74\u9650\u5f88\u957f\uff0c\u901a\u5e38\u4e0e\u5efa\u7b51\u4e3b\u4f53\u540c\u5468\u671f\u3002\u6696\u6c14\u7247\u672c\u4f53\u3001\u5206\u96c6\u6c34\u5668\u3001\u9600\u95e8\u7b49\u90e8\u4ef6\u4f4d\u4e8e\u53ef\u68c0\u4fee\u4f4d\u7f6e\uff0c\u53ef\u6b63\u5e38\u7ef4\u62a4\u66f4\u6362\u3002\u5173\u952e\u63a7\u5236\u70b9\u662f<strong>\u56de\u586b\u5c01\u69fd\u524d\u7684\u6253\u538b<\/strong>\uff1a0.6-0.8 MPa \u4fdd\u538b 24 \u5c0f\u65f6\u4e0d\u964d\u538b\uff0c\u4e14\u5fc5\u987b\u7559\u5b58\u8bb0\u5f55\u3002<\/div>\n<\/div>\n<div class=\"faq-item\">\n<h3>Q8\uff1a\u6210\u90fd\u5730\u533a\u505a\u6697\u57cb\u6696\u6c14\u7247\uff0c\u591a\u4e45\u80fd\u5b8c\u5de5\uff1f<\/h3>\n<div class=\"faq-ans\">\u6697\u57cb\u9700\u8981\u4e0e\u88c5\u4fee\u5de5\u5e8f\u914d\u5408\uff0c\u901a\u5e38\u5206\u4e24\u6b21\u8fdb\u573a\uff1a\u7b2c\u4e00\u6b21\u5728\u6c34\u7535\u8def\u65bd\u5de5\u9636\u6bb5\u505a\u5f00\u69fd\u3001\u5e03\u7ba1\u3001\u6253\u538b\u4e0e\u56de\u586b\uff1b\u7b2c\u4e8c\u6b21\u5728\u5899\u9762\u5730\u9762\u5b8c\u6210\u540e\u5b89\u88c5\u6696\u6c14\u7247\u3001\u6302\u7089\u4e0e\u63a7\u5236\u7cfb\u7edf\uff0c\u505a\u6574\u4f53\u8c03\u8bd5\u3002\u5177\u4f53\u5de5\u671f\u53d6\u51b3\u4e8e\u6237\u578b\u9762\u79ef\u3001\u56de\u8def\u6570\u91cf\u4e0e\u88c5\u4fee\u8fdb\u5ea6\uff0c\u9700\u73b0\u573a\u52d8\u6d4b\u540e\u786e\u8ba4\u3002<\/div>\n<\/div>\n<\/div>\n<p><!-- ===================== \u95e8\u5e97 ===================== --><\/p>\n<h2 id=\"store\">\u5341\u3001\u5230\u5e97\u4e0e\u52d8\u6d4b<\/h2>\n<div class=\"lm-store-grid\" style=\"display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0\">\n<div class=\"lm-store\" style=\"background:#fafafa;border:1px solid #eee;border-radius:10px;padding:12px 14px\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\u5b9e\u666f\u00b7\u6210\u90fd\u9ad8\u65b0\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\" loading=\"lazy\" style=\"width:100%;border-radius:8px;margin-bottom:8px\"><\/p>\n<div style=\"font-weight:700;color:#c0392b\">\u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/div>\n<div style=\"font-size:.88rem\">\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<\/div>\n<div style=\"font-size:.88rem\">\u7535\u8bdd\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><\/div>\n<div style=\"font-size:.88rem\"><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892|30.598786|104.074284|30.605656&amp;query_type=IDQ&amp;query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)&amp;zoom=17\" target=\"_blank\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97<\/a><\/div>\n<\/p><\/div>\n<div class=\"lm-store\" style=\"background:#fafafa;border:1px solid #eee;border-radius:10px;padding:12px 14px\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\u5b9e\u666f\u00b7\u6210\u90fd\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a\" loading=\"lazy\" style=\"width:100%;border-radius:8px;margin-bottom:8px\"><\/p>\n<div style=\"font-weight:700;color:#c0392b\">\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/div>\n<div style=\"font-size:.88rem\">\u6210\u90fd\u00b7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97\u533a<\/div>\n<div style=\"font-size:.88rem\">\u7535\u8bdd\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><\/div>\n<div style=\"font-size:.88rem\"><a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547|30.599807|104.07041|30.604665&amp;query_type=IDQ&amp;query=\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986(\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97)&amp;zoom=17.5\" target=\"_blank\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97<\/a><\/div>\n<\/p><\/div>\n<\/div>\n<p><!-- ===================== CTA ===================== --><\/p>\n<div class=\"cta-box\">\n<h3>\u6210\u90fd\u6697\u57cb\u6696\u6c14\u7247 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u8bbe\u8ba1\u4ea4\u5e95<\/h3>\n<p style=\"margin:4px 0\">\u5206\u623f\u95f4\u70ed\u8d1f\u8377\u8ba1\u7b97 \/ \u4e8c\u6b21\u7cfb\u7edf\u5fc5\u8981\u6027\u5224\u5b9a \/ \u7ae0\u9c7c\u5f0f\u56de\u8def\u5e03\u7f6e \/ \u63a7\u5236\u65b9\u6848\u9009\u578b<\/p>\n<p style=\"margin:6px 0;font-size:1.05rem\">\n    <a href=\"tel:02886131795\">028-86131795<\/a>\uff08\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff09\u3000<br \/>\n    <a href=\"tel:02865272586\">028-65272586<\/a>\uff08\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff09\n  <\/p>\n<p style=\"margin:10px 0 4px;font-size:.98rem\"><strong>\u9500\u552e\u987e\u95ee\u76f4\u8fde\uff08\u53ef\u76f4\u63a5\u62e8\u53f7\uff0c\u5fae\u4fe1\u540c\u53f7\uff09\uff1a<\/strong><\/p>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:8px 12px;margin:6px 0;font-size:.98rem\">\n    <span>\u4f59\u7ecf\u7406\uff08\u4f59\u7231\u82f1\uff09<br \/><a href=\"tel:13908183204\">139-0818-3204<\/a><\/span><br \/>\n    <span>\u90ed\u7ecf\u7406\uff08\u90ed\u52c7\u79c0\uff09<br \/><a href=\"tel:18100839248\">181-0083-9248<\/a><\/span><br \/>\n    <span>\u9ec4\u52c7\uff08\u6696\u901a\u987e\u95ee\uff09<br \/><a href=\"tel:15828489188\">15828489188<\/a><\/span>\n  <\/div>\n<p style=\"margin:4px 0 0;font-size:.85rem;color:#777\">\u4ee5\u4e0a\u53f7\u7801\u5747\u53ef\u76f4\u63a5\u62e8\u53f7\uff0c\u5fae\u4fe1\u540c\u53f7\u53ef\u6dfb\u52a0\u54a8\u8be2\u3002<\/p>\n<p style=\"margin:6px 0;font-size:.92rem\">\u53ef\u5bfc\u822a\u5230\u5e97\u5b9e\u5730\u4f53\u9a8c\u8bbe\u5907\uff1a<a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892|30.598786|104.074284|30.605656&amp;query_type=IDQ&amp;query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)&amp;zoom=17\" target=\"_blank\">\u5357\u5bcc\u68ee\u00b7\u65e5\u7acb\u65d7\u8230\u5e97<\/a> \uff5c <a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547|30.599807|104.07041|30.604665&amp;query_type=IDQ&amp;query=\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986(\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97)&amp;zoom=17.5\" target=\"_blank\">\u5317\u5bcc\u68ee\u00b7\u667a\u6167\u7a7a\u6c14\u9986<\/a><\/p>\n<p style=\"font-size:.85rem;color:#666;margin:6px 0 0\">\u670d\u52a1\u8303\u56f4\uff1a\u9ad8\u65b0\u3001\u53cc\u6d41\u3001\u90eb\u90fd\u3001\u9f99\u6cc9\u9a7f\u3001\u5929\u5e9c\u65b0\u533a\u3001\u9752\u7f8a\u3001\u6210\u534e\u3001\u89c6\u9ad8<\/p>\n<p>  <a class=\"btn\" href=\"tel:02886131795\">\u9884\u7ea6\u514d\u8d39\u52d8\u6d4b \u2192<\/a>\n<\/div>\n<p><!-- ===================== \u6587\u672b\u5185\u94fe ===================== --><\/p>\n<h3>\u5ef6\u4f38\u9605\u8bfb<\/h3>\n<p><a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><span class=\"title\">\u6848\u4f8b\u805a\u5408\u9875<\/span><span class=\"desc\">\u6210\u90fd\u5404\u5c0f\u533a\u6696\u6c14\u7247 \/ \u5730\u6696\u843d\u5730\u5b9e\u666f<\/span><\/a><br \/>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=4875\" target=\"_blank\"><span class=\"title\">\u552e\u540e\u5b9e\u5f55\u603b\u89c8<\/span><span class=\"desc\">\u771f\u5b9e\u62a5\u4fee\u5904\u7406\u8bb0\u5f55\u4e0e\u54cd\u5e94\u65f6\u6548<\/span><\/a><br \/>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\" target=\"_blank\"><span class=\"title\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/span><span class=\"desc\">\u5728\u7ebf\u6d4b\u7b97\u6237\u578b\u91c7\u6696\u9884\u7b97\u533a\u95f4<\/span><\/a><br \/>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\"><span class=\"title\">\u7ad9\u70b9\u5730\u56fe<\/span><span class=\"desc\">\u5168\u7ad9\u4ea7\u54c1 \/ \u767d\u76ae\u4e66 \/ \u65b9\u6848\u7d22\u5f15<\/span><\/a><br \/>\n<a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=7418\" target=\"_blank\"><span class=\"title\">\u4e94\u6052\u7cfb\u7edf\u4ef7\u683c\u9875<\/span><span class=\"desc\">\u66f4\u9ad8\u8212\u9002\u5ea6\u7684\u7cfb\u7edf\u65b9\u6848\u5bf9\u6bd4<\/span><\/a><\/p>\n<p class=\"tiny\" style=\"margin-top:26px;padding-top:12px;border-top:1px solid #eee\">\n<strong>\u514d\u8d23\u58f0\u660e\uff1a<\/strong>\u672c\u9875\u5185\u5bb9\u4f5c\u4e3a\u6696\u901a\u8bbe\u8ba1\u77e5\u8bc6\u79d1\u666e\u4e0e\u65bd\u5de5\u53c2\u8003\uff0c\u5177\u4f53\u65b9\u6848\u9700\u7ed3\u5408\u623f\u5c4b\u5b9e\u9645\u60c5\u51b5\u3001\u6237\u578b\u7ed3\u6784\u3001\u4fdd\u6e29\u6761\u4ef6\u4e0e\u9884\u7b97\u7efc\u5408\u8bc4\u4f30\uff1b\u70ed\u8d1f\u8377\u3001\u7ba1\u5f84\u3001\u6cf5\u9009\u578b\u7b49\u53c2\u6570\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e0e\u8bbe\u8ba1\u8ba1\u7b97\u4e3a\u51c6\uff0c\u8f85\u6750\u54c1\u724c\u89c4\u683c\u4ee5\u5f53\u671f\u4f9b\u8d27\u4e0e\u5408\u540c\u7ea6\u5b9a\u4e3a\u51c6\u3002\u6d89\u53ca\u5de5\u7a0b\u5b9e\u65bd\u8bf7\u54a8\u8be2\u4e13\u4e1a\u6696\u901a\u5de5\u7a0b\u5e08\u3002<br \/>\n\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\u3000|\u3000\u89c4\u8303\u7248\u672c V2.0\u3000|\u3000\u4fee\u8ba2\u65e5\u671f 2026-08-30\n<\/p>\n<\/div>\n<p><!-- \/.lm-wrap --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6697\u57cb\u6696\u6c14\u7247\u8bbe\u8ba1\u89c4\u8303\uff08\u6210\u90fd\uff09\u56db\u8981\u7d20\u8bbe\u8ba1\u6807\u51c6 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-11894","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u65b0\u623f\u6bdb\u576f\u6697\u57cb\u7ae0\u9c7c\u5f0f\u6696\u6c14\u7247\u5b8c\u6574\u8bbe\u8ba1\u6807\u51c6\uff1b\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u5927\u8981\u7d20\uff0c\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u636e\u3001\u6253\u538b\u9a8c\u6536\u6e05\u5355\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=11894\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u65b0\u623f\u6bdb\u576f\u6697\u57cb\u7ae0\u9c7c\u5f0f\u6696\u6c14\u7247\u5b8c\u6574\u8bbe\u8ba1\u6807\u51c6\uff1b\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u5927\u8981\u7d20\uff0c\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u636e\u3001\u6253\u538b\u9a8c\u6536\u6e05\u5355\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=11894\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-26T17:23:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-glgdylw.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894\",\"name\":\"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/gdwxc-zls-glgdylw.jpg\",\"datePublished\":\"2026-08-30T14:21:21+00:00\",\"dateModified\":\"2026-10-26T17:23:21+00:00\",\"description\":\"\u6210\u90fd\u65b0\u623f\u6bdb\u576f\u6697\u57cb\u7ae0\u9c7c\u5f0f\u6696\u6c14\u7247\u5b8c\u6574\u8bbe\u8ba1\u6807\u51c6\uff1b\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u5927\u8981\u7d20\uff0c\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u636e\u3001\u6253\u538b\u9a8c\u6536\u6e05\u5355\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/gdwxc-zls-glgdylw.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/gdwxc-zls-glgdylw.jpg\",\"width\":1279,\"height\":1706},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=11894#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u65b0\u623f\u6bdb\u576f\u6697\u57cb\u7ae0\u9c7c\u5f0f\u6696\u6c14\u7247\u5b8c\u6574\u8bbe\u8ba1\u6807\u51c6\uff1b\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u5927\u8981\u7d20\uff0c\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u636e\u3001\u6253\u538b\u9a8c\u6536\u6e05\u5355\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=11894","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u65b0\u623f\u6bdb\u576f\u6697\u57cb\u7ae0\u9c7c\u5f0f\u6696\u6c14\u7247\u5b8c\u6574\u8bbe\u8ba1\u6807\u51c6\uff1b\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u5927\u8981\u7d20\uff0c\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u636e\u3001\u6253\u538b\u9a8c\u6536\u6e05\u5355\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=11894","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-26T17:23:21+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-glgdylw.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=11894","url":"https:\/\/longmai-nt.com\/?page_id=11894","name":"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=11894#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=11894#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-glgdylw.jpg","datePublished":"2026-08-30T14:21:21+00:00","dateModified":"2026-10-26T17:23:21+00:00","description":"\u6210\u90fd\u65b0\u623f\u6bdb\u576f\u6697\u57cb\u7ae0\u9c7c\u5f0f\u6696\u6c14\u7247\u5b8c\u6574\u8bbe\u8ba1\u6807\u51c6\uff1b\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u5927\u8981\u7d20\uff0c\u4e8c\u6b21\u7cfb\u7edf\u5f3a\u5236\u5224\u636e\u3001\u6253\u538b\u9a8c\u6536\u6e05\u5355\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=11894#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=11894"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=11894#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-glgdylw.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gdwxc-zls-glgdylw.jpg","width":1279,"height":1706},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=11894#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u65b0\u623f\u6697\u57cb\u6696\u6c14\u7247\uff5c\u7ae0\u9c7c\u5f0f\u8bbe\u8ba1\u65bd\u5de5\u89c4\u8303"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11894"}],"version-history":[{"count":8,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11894\/revisions"}],"predecessor-version":[{"id":16659,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/11894\/revisions\/16659"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}