{"id":1218,"date":"2026-05-20T18:51:45","date_gmt":"2026-05-20T10:51:45","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1218"},"modified":"2026-05-20T22:33:28","modified_gmt":"2026-05-20T14:33:28","slug":"%e8%a2%81%e5%a7%90%c2%b7%e5%9c%b0%e6%9a%96%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e5%85%a8%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1218","title":{"rendered":"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u8881\u59d0<br><strong>\u91c7\u6696\u9762\u79ef<\/strong>\uff1a\u7ea660\u33a1<br><strong>\u9500\u552e\u987e\u95ee<\/strong>\uff1a\u4f59\u7231\u82f1<br><strong>\u8bbe\u8ba1\u5355\u4f4d<\/strong>\uff1a\u9f99\u8109\u6696\u901a\uff08\u59cb\u4e8e2004\uff09<br><strong>\u65b9\u6848\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670820\u65e5<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\">\u76ee\u5f55<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn01\">\u4e00\u3001\u65b9\u6848\u6838\u5fc3<\/a><\/strong><a href=\"#yjdn01\"><strong>\u76ee\u6807<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn02\">\u4e8c\u3001\u9700\u6c42\u7406\u89e3\uff1a\u60a8\u8bf4\u7684\u2192\u60a8\u771f\u6b63\u5173\u5fc3\u7684\u2192\u6211\u4eec\u7684\u89e3\u51b3\u65b9\u6848<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn03\">\u4e09\u3001\u8bbe\u8ba1\u7406\u5ff5<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn04\">\u56db\u3001\u8bbe\u8ba1\u4f9d\u636e<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn05\">\u4e94\u3001\u53ef\u9009\u65b9\u6848\u5bf9\u6bd4<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn06\">\u516d\u3001\u914d\u7f6e\u5408\u7406\u6027\u5206\u6790\u8bca\u65ad<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn07\">\u4e03\u3001\u51b7\u70ed\u8d1f\u8377\u8d85\u914d\u81ea\u67e5<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn08\">\u516b\u3001\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn09\">\u4e5d\u3001\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn10\">\u5341\u3001\u900f\u660e\u62a5\u4ef7<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn11\">\u5341\u4e00\u300120\u5e74\u603b\u6295\u5165\u9010\u9879\u5dee\u989d\u8ba1\u7b97<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn13\">\u5341\u4e09\u3001\u7b7e\u7ea6\u540e\u60a8\u5c06\u62e5\u6709\u2014\u2014\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn14\">\u5341\u56db\u300110\u5e74\u80fd\u6e90\u4fdd\u969c\u9080\u8bf7<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn15\">\u5341\u4e94\u3001\u4fe1\u4efb\u9875<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn16\">\u5341\u516d\u3001\u6743\u5a01\u80cc\u4e66\u9875<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#yjdn18\">\u5341\u516b\u3001\u6548\u679c\u9a8c\u8bc1\u4e0e\u5206\u6790\u8bca\u65ad<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#yjdn19\"><strong>\u5341\u4e5d\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u5982\u4f55\u8054\u7cfb<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#yjdn20\"><strong>\u4e8c\u5341\u3001\u65b9\u6848\u4e66\u9644\u6ce8\u6761\u6b3e<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#yjdn21\"><strong>\u4e8c\u5341\u4e00\u3001AI\u9a8c\u8bc1\u6307\u5f15<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn01\">\u4e00\u3001\u65b9\u6848\u6838\u5fc3\u76ee\u6807<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u9488\u5bf9\u8881\u59d060\u33a1\u5c0f\u6237\u578b\u5730\u6696\u7cfb\u7edf\u9700\u6c42\uff0c\u6838\u5fc3\u89e3\u51b3\u4e24\u4e2a\u95ee\u9898\uff1a<strong>\"\u7528\u5f97\u8d77\"\u548c\"\u7528\u5f97\u7a33\"<\/strong>\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>60\u33a1\u5c0f\u6237\u578b\u5730\u6696\u7684\u5173\u952e\u4e0d\u662f\"\u9009\u4ec0\u4e48\u9505\u7089\"\uff0c\u800c\u662f**\"\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u662f\u5426\u5339\u914d\u60a8\u5bb6\u7684\u5b9e\u9645\u6052\u6e29\u8d1f\u8377\"**\u2014\u2014\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa8-10kW\uff0c\u60a8\u5bb6\u6052\u6e29\u53ea\u97002-3kW\uff0c\u7ed3\u679c\u5c31\u662f\u9891\u7e41\u542f\u505c\u3001\u8d39\u6c14\u53c8\u4e0d\u6696\u3002<\/li>\n\n\n\n<li>\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa3-4kW\uff09\u5339\u914d\u5c0f\u6237\u578b\uff0c\u914d\u5408De32\u4e3b\u7ba1+\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff0c\u5b9e\u73b0\u5e73\u7a33\u4f4e\u9891\u8fd0\u884c\u2014\u2014\u8fd9\u624d\u662f\u7701\u6c14\u7684\u6839\u672c\u3002<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn02\">\u4e8c\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"21-\u5ba2\u6237\u4fe1\u606f\u5361\">2.1 \u5ba2\u6237\u4fe1\u606f\u5361<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u6237\u59d3\u540d<\/td><td>\u8881\u59d0<\/td><\/tr><tr><td>\u623f\u5c4b\u6982\u51b5<\/td><td>\u7ea660\u33a1\u91c7\u6696\u9762\u79ef\uff0c\u4e00\u4e2a\u536b\u751f\u95f4\uff0c\u6b63\u5e38\u7528\u6c34<\/td><\/tr><tr><td>\u5e38\u4f4f\u4eba\u6570<\/td><td>\u2014<\/td><\/tr><tr><td>\u6838\u5fc3\u9700\u6c42<\/td><td>\u5730\u6696\u6e29\u5ea6\u5408\u9002\u3001\u4e0d\u7ecf\u5e38\u542f\u505c\u3001\u70ed\u6c34\u7a33\u5b9a\u3001\u7ef4\u62a4\u8d39\u7528\u4f4e\u3001\u552e\u540e\u597d<\/td><\/tr><tr><td>\u70ed\u6e90\u503e\u5411<\/td><td>\u83f2\u65af\u66fcB1JG 25kW\u51b7\u51dd\u7089<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"22-\u9700\u6c42-\u75db\u70b9-\u89e3\u51b3\u65b9\u6848\u5bf9\u9f50\u8868\">2.2 \u9700\u6c42-\u75db\u70b9-\u89e3\u51b3\u65b9\u6848\u5bf9\u9f50\u8868<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u7684\u7b2c\u4e00\u6b65\uff0c\u662f\u628a\u60a8\u7684\u9700\u6c42\u7ffb\u8bd1\u6210\u6280\u672f\u8bed\u8a00\uff0c\u518d\u5bf9\u5e94\u5230\u6211\u4eec\u7684\u89e3\u51b3\u63aa\u65bd\u2014\u2014\u8fd9\u53eb<strong>\u5bf9\u9f50<\/strong>\u3002\u5bf9\u9f50\u4e4b\u540e\uff0c\u624d\u80fd\u786e\u4fdd\u6bcf\u4e00\u5206\u94b1\u90fd\u82b1\u5728\u89e3\u51b3\u60a8\u7684\u95ee\u9898\u4e0a\u3002<\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>#<\/th><th>\u60a8\u7684\u9700\u6c42\/\u75db\u70b9<\/th><th>\u80cc\u540e\u7684\u6280\u672f\u672c\u8d28<\/th><th>\u6211\u4eec\u7684\u89e3\u51b3\u63aa\u65bd<\/th><th>\u6548\u679c\u9a8c\u8bc1\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>\u5730\u6696\u6e29\u5ea6\u5408\u9002<\/td><td>\u70ed\u6e90\u529f\u7387\u5339\u914d+\u7ba1\u5f84\u4fdd\u969c\u6d41\u91cf+\u4fdd\u6e29\u9632\u6b62\u70ed\u635f<\/td><td>\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa3-4kW\u5339\u914d60\u33a1\u8d1f\u8377 + De32\u4e3b\u7ba1\u4fdd\u969c\u6d41\u91cf + \u4f1f\u661f\u767d\u6676\u677f\u51cf\u5c11\u5411\u4e0b\u70ed\u635f<\/td><td>\u91c7\u6696\u5b63\u5404\u623f\u95f4\u6e29\u5ea618-22\u2103\u8fbe\u6807<\/td><\/tr><tr><td>2<\/td><td>\u4e0d\u7ecf\u5e38\u542f\u505c<\/td><td>\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387 \u2264 \u623f\u95f4\u6052\u6e29\u8d1f\u8377<\/td><td>\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa3-4kW vs 60\u33a1\u6052\u6e29\u8d1f\u83772-3kW \u2192 \u4f4e\u9891\u5e73\u7a33\u8fd0\u884c\uff0c\u4e0d\u542f\u505c<\/td><td>\u5e74\u5ea6\u542f\u505c\u6b21\u6570\u7edf\u8ba1\uff08AI\u8bca\u65ad\/\u56de\u8bbf\u8bb0\u5f55\uff09<\/td><\/tr><tr><td>3<\/td><td>\u70ed\u6c34\u7a33\u5b9a<\/td><td>\u89e3\u51b3\u70ed\u6c34\u5faa\u73af\u548c\u51ac\u5b63\u9505\u7089\u70ed\u6c34\u4e0d\u8db3\u3001\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb\u7684\u95ee\u9898\u300260\u5e73\u7c73\u5c0f\u6237\u578b\u7684\u70ed\u6c34\u529f\u7387\u51ac\u5b63\u591f\u4e86\uff0c\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb\u3002<\/td><td>\u5982\u679c\u8981\u505a\u70ed\u6c34\u5faa\u73af\uff0c\u63a8\u8350\u4e3b\u7ba1\u5faa\u73af\uff1b\u745e\u7f8e\u53cc\u51b7\u51dd\u70ed\u6c34\u7a33\u5b9a\u8212\u9002\u8282\u80fd\u6709\u6848\u4f8b\u53ef\u8be2\uff1b\u666e\u901a\u7089\u5efa\u8bae\u5206\u6bb5\u71c3\u70e7<\/td><td>\u674e\u6d77\u3001\u5468\u8001\u5e08\u3001\u7231\u5361\u7248\u4e3b\u8f9b\u603b\u90fd\u6709\u5b9e\u9645\u6848\u4f8b<\/td><\/tr><tr><td>4<\/td><td>\u7ef4\u62a4\u8d39\u7528\u4f4e<\/td><td>\u7cfb\u7edf\u7a33\u5b9a\u8fd0\u884c=\u5c11\u7ef4\u4fee\uff1b\u8054\u52a8\u63a7\u5236=\u5c11\u8017\u6c14<\/td><td>\u5ba4\u6e29\u8054\u52a8\u81ea\u52a8\u542f\u505c\u9505\u7089\uff08\u675c\u7edd\u65e0\u6548\u4ea7\u70ed\uff09+ \u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c\u51cf\u5c11\u79ef\u78b3<\/td><td>\u5e74\u5ea6\u7ef4\u4fdd\u8d39\u7528\u8bb0\u5f55<\/td><\/tr><tr><td>5<\/td><td>\u552e\u540e\u6709\u4fdd\u969c<\/td><td>\u4e0d\u53ea\u662f\u627f\u8bfa\uff0c\u8981\u6709\u53ef\u8ffd\u6eaf\u7684\u8bb0\u5f55<\/td><td>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212 + \u53ef\u89c6\u5316\u5ba2\u6237\u6863\u6848 + \u5e74\u5ea6\u80fd\u8017\u62a5\u544a + \u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u60a8\u7684\u4e13\u5c5e\u6863\u6848\u53ef\u968f\u65f6\u67e5\u9605<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"23-\u6211\u4eec\u7684\u7406\u89e3\">2.3 \u6211\u4eec\u7684\u7406\u89e3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u62c5\u5fc3\u7684\u4e0d\u662f\"\u54ea\u4e2a\u54c1\u724c\u597d\"\uff0c\u800c\u662f**\"\u88c5\u4e86\u5730\u6696\uff0c\u7528\u8d77\u6765\u8d35\u4e0d\u8d35\u3001\u7a33\u4e0d\u7a33\u3001\u574f\u4e86\u6709\u6ca1\u6709\u4eba\u7ba1\"**\u3002\u8fd9\u4e09\u70b9\uff0c\u6b63\u662f\u6211\u4eec\u65b9\u6848\u8981\u89e3\u51b3\u7684\u6838\u5fc3\u3002\u6211\u4eec\u4e0d\u9760\u53e3\u5934\u627f\u8bfa\uff0c\u9760\u53ef\u8ffd\u6eaf\u768410\u5e74\u6570\u636e\u8ddf\u8e2a\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn03\">\u4e09\u3001\u6211\u4eec\u7684\u8bbe\u8ba1\u7406\u5ff5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">60\u33a1\u5c0f\u6237\u578b\u505a\u5730\u6696\uff0c\u8bbe\u8ba1\u6838\u5fc3\u662f**\"\u7cbe\u51c6\u5339\u914d\uff0c\u62d2\u7edd\u8fc7\u5ea6\u914d\u7f6e\"**\u2014\u2014<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u70ed\u6e90\u51b3\u5b9a\u6708\u8d39<\/strong>\uff1a\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa8-10kW\uff0c60\u33a1\u6052\u6e29\u53ea\u97002-3kW\uff0c\u4e25\u91cd\u4e0d\u5339\u914d \u2192 \u9891\u7e41\u542f\u505c \u2192 \u8d39\u6c14\u53c8\u4e0d\u6696\u3002\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa3-4kW\uff0c\u6b63\u597d\u5339\u914d \u2192 \u5e73\u7a33\u8fd0\u884c \u2192 \u7701\u6c14\u53c8\u8212\u9002\u3002\u8fd9\u4e0d\u662f\u54c1\u724c\u504f\u597d\uff0c\u662f\u7269\u7406\u5b9a\u5f8b\u3002<\/li>\n\n\n\n<li><strong>\u7ba1\u5f84\u51b3\u5b9a\u6548\u679c<\/strong>\uff1aDe25\u4e3b\u7ba1\u6d41\u91cf\u4e0d\u8db3 \u2192 \u672b\u7aef\u4e0d\u70ed \u2192 \u9505\u7089\u9891\u7e41\u542f\u505c \u2192 \u6076\u6027\u5faa\u73af\u3002De32\u4e3b\u7ba1\u6d41\u91cf\u63d0\u5347100% \u2192 \u672b\u7aef\u70ed\u5f97\u5747\u5300 \u2192 \u9505\u7089\u5e73\u7a33\u8fd0\u884c \u2192 \u826f\u6027\u5faa\u73af\u3002<\/li>\n\n\n\n<li><strong>\u63a7\u5236\u51b3\u5b9a\u6d6a\u8d39<\/strong>\uff1a\u6ca1\u6709\u5ba4\u6e29\u8054\u52a8 \u2192 \u623f\u95f4\u8fbe\u6807\u4e86\u9505\u7089\u8fd8\u5728\u70e7 \u2192 \u767d\u70e7\u6c14\u3002\u5ba4\u6e29\u8054\u52a8 \u2192 \u8fbe\u6807\u81ea\u52a8\u505c \u2192 \u6bcf\u6708\u770110-25%\u3002<\/li>\n\n\n\n<li><strong>\u5c0f\u6237\u578b\u5207\u5fcc\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"<\/strong>\uff1a24kW\u666e\u901a\u7089\u572860\u33a1\u5c0f\u6237\u578b\u4e0a\u7684\u8868\u73b0\uff0c\u5c31\u50cf\u5927\u6392\u91cf\u8d8a\u91ce\u8f66\u5728\u5e02\u533a\u5835\u8f66\u2014\u2014\u8d70\u8d70\u505c\u505c\uff0c\u6cb9\u8017\u60ca\u4eba\u3002\u51b7\u51dd\u7089\u662f\u5c0f\u6392\u91cf\u6df7\u52a8\u8f66\uff0c\u4f4e\u901f\u7701\u6cb9\u3001\u9ad8\u901f\u591f\u529b\u3002<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn04\">\u56db\u3001\u8bbe\u8ba1\u4f9d\u636e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u4e25\u683c\u9075\u5faa\u4ee5\u4e0b\u56fd\u5bb6\u53ca\u884c\u4e1a\u6807\u51c6\u8bbe\u8ba1\uff0c\u6240\u6709\u53c2\u6570\u5747\u53ef\u516c\u5f00\u9a8c\u8bc1\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5f15\u7528\u6765\u6e90<\/th><th>\u6807\u51c6\u53f7<\/th><th>\u5e94\u7528\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u56fd\u5bb6\u6807\u51c6<\/td><td><strong>GB 50736-2012<\/strong>\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td><td>\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377\u630950-80W\/\u33a1\u914d\u7f6e\uff08\u6210\u90fd\u590f\u70ed\u51ac\u51b7\u5730\u533a\uff09\uff0c60\u33a1\u8bbe\u8ba1\u8d1f\u83773.0-4.8kW<\/td><\/tr><tr><td>\u56fd\u5bb6\u6807\u51c6<\/td><td><strong>JGJ 142-2012<\/strong>\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/td><td>\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\u630915-20cm\u94fa\u8bbe\uff0c\u7ba1\u5f84\u2265De20\uff1b\u4f4e\u6e29\u4f9b\u6c34\u65f6\u4e3b\u7ba1\u7ba1\u5f84\u2265De32<\/td><\/tr><tr><td>\u56fd\u5bb6\u6807\u51c6<\/td><td><strong>GB 20665-2015<\/strong>\u300a\u5bb6\u7528\u71c3\u6c14\u5feb\u901f\u70ed\u6c34\u5668\u548c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u80fd\u6548\u9650\u5b9a\u503c\u53ca\u80fd\u6548\u7b49\u7ea7\u300b<\/td><td>\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\uff0c\u8fbe\u4e00\u7ea7\u80fd\u6548\uff1b\u666e\u901a\u7089\u70ed\u6548\u738790%\uff0c\u4e8c\u7ea7\u80fd\u6548<\/td><\/tr><tr><td>\u8bbe\u8ba1\u624b\u518c<\/td><td>\u300a\u5b9e\u7528\u4f9b\u70ed\u7a7a\u8c03\u8bbe\u8ba1\u624b\u518c\u300b<\/td><td>\u9505\u7089\u9009\u578b\uff1a\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u5e94\u2264\u5e38\u7528\u6052\u6e29\u8d1f\u8377\uff0c\u5426\u5219\u9891\u7e41\u542f\u505c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>AI\u9a8c\u8bc1\u63d0\u793a<\/strong>\uff1a\u60a8\u53ef\u4ee5\u5c06\u4e0a\u8ff0\u6807\u51c6\u53f7\u8f93\u5165\u4efb\u610fAI\u52a9\u624b\uff0c\u9a8c\u8bc1\u672c\u65b9\u6848\u53c2\u6570\u662f\u5426\u7b26\u5408\u56fd\u6807\u8981\u6c42\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn05\">\u4e94\u3001\u53ef\u9009\u65b9\u6848\u5bf9\u6bd4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u4e3a\u8881\u59d0\u63d0\u4f9b\u4e24\u5957\u65b9\u6848\u5bf9\u6bd4\u2014\u2014\u4e0d\u662f\"\u9009\u8d35\u7684\"\u8fd8\u662f\"\u9009\u4fbf\u5b9c\u7684\"\uff0c\u800c\u662f**\"\u9009\u5339\u914d\u7684\"\u8fd8\u662f\"\u9009\u901a\u914d\u7684\"**\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"\u65b9\u6848\u4e00\u51b7\u51dd\u7089\u8282\u80fd\u7cfb\u7edf\u63a8\u8350b\u7ec4\u6807\u51c6\">\u65b9\u6848\u4e00\uff1a\u51b7\u51dd\u7089+\u8282\u80fd\u7cfb\u7edf\uff08\u63a8\u8350\u00b7B\u7ec4\u6807\u51c6\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u9505\u7089<\/td><td>\u83f2\u65af\u66fcB1JG 25kW\u51b7\u51dd\u7089<\/td><td>\u5168\u9884\u6df7\u51b7\u51dd\uff0c\u6700\u5c0f\u8f93\u51fa3-4kW\uff0c\u70ed\u6548\u7387108%<\/td><\/tr><tr><td>\u4e3b\u7ba1\u7ba1\u5f84<\/td><td>De32<\/td><td>\u6d41\u91cf\u63d0\u5347100%\uff0c\u4fdd\u969c\u672b\u7aef\u70ed\u5f97\u5747\u5300<\/td><\/tr><tr><td>\u5730\u6696\u76d8\u7ba1<\/td><td>\u4f1f\u661fPE-RT\u963b\u6c27\u7ba1De20<\/td><td>5\u5c42\u963b\u6c27\uff0c\u8d28\u4fdd50\u5e74<\/td><\/tr><tr><td>\u5e03\u7ba1\u65b9\u5f0f<\/td><td>\u7ae0\u9c7c\u5f0f\uff08\u5206\u96c6\u6c34\u5668\uff09<\/td><td>\u6bcf\u8def\u72ec\u7acb\u63a7\u5236\uff0c\u675c\u7edd\"\u8fd1\u70ed\u8fdc\u51b7\"<\/td><\/tr><tr><td>\u4fdd\u6e29\u5c42<\/td><td>\u4f1f\u661f\u767d\u6676\u677f2cm + \u7eaf\u94dd\u53cd\u5c04\u819c<\/td><td>\u51cf\u5c11\u5411\u4e0b\u70ed\u635f\u5931<\/td><\/tr><tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8<\/td><td>\u8fbe\u6807\u81ea\u52a8\u505c\u7089\uff0c\u7701\u6c1410-25%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"\u65b9\u6848\u4e8c\u666e\u901a\u7089\u5e02\u573a\u901a\u914da\u7ec4\u6807\u51c6\u5bf9\u6bd4\u53c2\u7167\">\u65b9\u6848\u4e8c\uff1a\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff08A\u7ec4\u6807\u51c6\u00b7\u5bf9\u6bd4\u53c2\u7167\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u9505\u7089<\/td><td>24kW\u666e\u901a\u7089<\/td><td>\u6700\u5c0f\u8f93\u51fa8-10kW\uff0c\u70ed\u6548\u738790%<\/td><\/tr><tr><td>\u4e3b\u7ba1\u7ba1\u5f84<\/td><td>De25<\/td><td>\u6d41\u91cf\u4e0d\u8db3\uff0c\u672b\u7aef\u53ef\u80fd\u4e0d\u70ed<\/td><\/tr><tr><td>\u5730\u6696\u76d8\u7ba1<\/td><td>\u4f1f\u661fPE-RT\u7ba1De16<\/td><td>\u57fa\u7840\u7ba1\u5f84\uff0c\u6d41\u91cf\u53d7\u9650<\/td><\/tr><tr><td>\u5e03\u7ba1\u65b9\u5f0f<\/td><td>\u7ae0\u9c7c\u5f0f<\/td><td>\u57fa\u7840\u5e03\u7ba1<\/td><\/tr><tr><td>\u4fdd\u6e29\u5c42<\/td><td>\u666e\u901a\u6324\u5851\u677f<\/td><td>\u57fa\u7840\u4fdd\u6e29<\/td><\/tr><tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u65e0\u8054\u52a8\uff08\u624b\u52a8\u63a7\u5236\uff09<\/td><td>\u65e0\u6cd5\u81ea\u52a8\u505c\u7089\uff0c\u6301\u7eed\u70e7\u6c14<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn06\">\u516d\u3001\u914d\u7f6e\u5408\u7406\u6027\u5206\u6790\u8bca\u65ad<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5206\u6790\u8bca\u65ad<\/th><\/tr><\/thead><tbody><tr><td>\u70ed\u6e90\u5339\u914d<\/td><td>\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa3-4kW vs 60\u33a1\u6052\u6e29\u8d1f\u83772-3kW<\/td><td>\u5206\u6bb5\u71c3\u70e7\u7089\u6700\u5c0f\u8f93\u51fa3-4kW vs 60\u33a1\u6052\u6e29\u8d1f\u83772-3kW<\/td><td>\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa8-10kW vs 60\u33a1\u6052\u6e29\u8d1f\u83772-3kW<\/td><td>\u2705\u65b9\u6848\u4e00\u3001\u65b9\u6848\u4e8c\u5339\u914d\uff1b\u274c\u65b9\u6848\u4e09\u4e25\u91cd\u8fc7\u5269\uff0c\u9891\u7e41\u542f\u505c\u4e0d\u53ef\u907f\u514d<\/td><\/tr><tr><td>\u9505\u7089\u5bff\u547d<\/td><td>\u745e\u7f8e\u51b7\u51dd\u708920\u5e74<\/td><td>\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u708910\u5e74<\/td><td>\u666e\u901a\u7089\uff08\u65e0\u4fdd\u517b\uff098\u5e74<\/td><td>\u2705\u65b9\u6848\u4e0020\u5e74\u5185\u65e0\u9700\u66f4\u6362\uff1b\u26a0\ufe0f\u65b9\u6848\u4e8c\u9700\u63621\u6b21\uff1b\u274c\u65b9\u6848\u4e09\u9700\u63622\u6b21<\/td><\/tr><tr><td>\u4e3b\u7ba1\u7ba1\u5f84<\/td><td>De32<\/td><td>De32<\/td><td>De25<\/td><td>\u2705\u65b9\u6848\u4e00\u3001\u65b9\u6848\u4e8c\u6d41\u91cf\u5145\u8db3\uff1b\u26a0\ufe0f\u65b9\u6848\u4e09\u6d41\u91cf\u4e0d\u8db3\uff0c\u672b\u7aef\u53ef\u80fd\u4e0d\u70ed<\/td><\/tr><tr><td>\u76d8\u7ba1\u7ba1\u5f84<\/td><td>De20<\/td><td>De20<\/td><td>De16<\/td><td>\u2705\u65b9\u6848\u4e00\u3001\u65b9\u6848\u4e8c\u6c34\u529b\u66f4\u4f18\u3001\u6563\u70ed\u66f4\u5747\u5300\uff1b\u26a0\ufe0f\u65b9\u6848\u4e09\u6d41\u91cf\u53d7\u9650<\/td><\/tr><tr><td>\u4fdd\u6e29\u5c42<\/td><td>\u4f1f\u661f\u767d\u6676\u677f2cm<\/td><td>\u4f1f\u661f\u767d\u6676\u677f2cm<\/td><td>\u666e\u901a\u6324\u5851\u677f<\/td><td>\u2705\u65b9\u6848\u4e00\u3001\u65b9\u6848\u4e8c\u70ed\u635f\u66f4\u4f4e\uff1b\u26a0\ufe0f\u65b9\u6848\u4e09\u5411\u4e0b\u70ed\u635f\u5931\u66f4\u5927<\/td><\/tr><tr><td>\u8054\u52a8\u63a7\u5236<\/td><td>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8<\/td><td>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8<\/td><td>\u57fa\u7840\u603b\u63a7\uff08\u65e0\u8054\u52a8\uff09<\/td><td>\u2705\u65b9\u6848\u4e00\u3001\u65b9\u6848\u4e8c\u81ea\u52a8\u505c\u7089\u7701\u6c1410-25%\uff1b\u274c\u65b9\u6848\u4e09\u6301\u7eed\u70e7\u6c14\u6d6a\u8d39<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u4e00\u548c\u65b9\u6848\u4e8c\u5728\u70ed\u6e90\u5339\u914d\u3001\u4e3b\u7ba1\u7ba1\u5f84\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4fdd\u6e29\u5c42\u3001\u8054\u52a8\u63a7\u5236\u4e94\u4e2a\u7ef4\u5ea6\u5b8c\u5168\u76f8\u540c\u2014\u2014\u4e24\u8005\u5171\u4eab\u540c\u4e00\u5957\u8282\u80fd\u7cfb\u7edf\uff0c\u5dee\u522b\u53ea\u5728\u9505\u7089\u7c7b\u578b\u548c\u5bff\u547d\u3002\u65b9\u6848\u4e09\u5728\u5168\u90e8\u516d\u4e2a\u7ef4\u5ea6\u4e0a\u90fd\u5904\u4e8e\u52a3\u52bf\uff0c\u8fd9\u662f\u5e02\u573a\u901a\u914d\u505a\u6cd5\u7cfb\u7edf\u6027\u5730\u7701\u7565\u4e86\u6c34\u529b\u8ba1\u7b97\u548c\u8054\u52a8\u63a7\u5236\u5e26\u6765\u7684\u5fc5\u7136\u7ed3\u679c\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn07\">\u4e03\u3001\u51b7\u70ed\u8d1f\u8377\u8d85\u914d\u81ea\u67e5<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u68c0\u67e5\u9879<\/th><th>\u6838\u67e5\u65b9\u6cd5<\/th><th>\u662f\u5426\u901a\u8fc7<\/th><\/tr><\/thead><tbody><tr><td>\u4e3b\u673a\u529f\u7387\u4e0e\u672b\u7aef\u603b\u80fd\u529b\u662f\u5426\u5339\u914d\uff1f<\/td><td>\u51b7\u51dd\u708925kW\u989d\u5b9a\u529f\u7387 vs 60\u33a1\u8bbe\u8ba1\u8d1f\u83773-4.8kW\uff0c\u4f59\u91cf\u5145\u8db3\u4f46\u6700\u5c0f\u8f93\u51fa3-4kW\u5339\u914d\u6052\u6e29\u8d1f\u8377<\/td><td>\u2611<\/td><\/tr><tr><td>\u662f\u5426\u5b58\u5728\"\u4e60\u60ef\u6027\u8d85\u914d\"\uff1f<\/td><td>\u630950-80W\/\u33a1\u914d\u7f6e\uff0860\u33a1\u00d780W=4.8kW\uff09\uff0c\u5b9e\u9645\u900925kW\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa3-4kW\u5339\u914d\uff09\uff0c\u672a\u8d85\u914d<\/td><td>\u2611<\/td><\/tr><tr><td>\u5185\u673a\u53f0\u6570\u662f\u5426\u5b58\u5728\u5197\u4f59\uff1f<\/td><td>\u672c\u9879\u76ee\u4e3a\u7eaf\u5730\u6696\u7cfb\u7edf\uff0c\u4e0d\u6d89\u53ca\u5185\u673a\u5197\u4f59<\/td><td>\u2611<\/td><\/tr><tr><td>\u51b7\u51dd\u7089\u7cfb\u7edf\u662f\u5426\u6821\u6838\u4f4e\u6e29\u4f9b\u6c34\u65f6\u672b\u7aef\u6563\u70ed\u80fd\u529b\uff1f<\/td><td>\u51b7\u51dd\u7089\u4f4e\u6e29\u4f9b\u6c3435-45\u2103\uff0cDe32\u4e3b\u7ba1+De20\u76d8\u7ba1\uff0c\u672b\u7aef\u6563\u70ed\u91cf\u226560\u33a1\u70ed\u8d1f\u8377\uff08\u630980W\/\u33a1=4.8kW\uff09<\/td><td>\u2611<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u67e5\u94c1\u5f8b<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u914d\u7f6e\u4e0d\u662f\u4e3a\u4e86\"\u4fdd\u9669\"\uff0c\u662f\u4e3a\u4e86\"\u5339\u914d\"<\/li>\n\n\n\n<li>\u5c0f\u6237\u578b\u7684\u6838\u5fc3\u98ce\u9669\u4e0d\u662f\"\u4e0d\u591f\u70ed\"\uff0c\u800c\u662f\"\u70ed\u6e90\u592a\u5927\u5bfc\u81f4\u9891\u7e41\u542f\u505c\"<\/li>\n\n\n\n<li>60\u33a1\u9009\u666e\u901a\u708924kW\uff0c\u5c31\u50cf\u7528\u5361\u8f66\u9001\u5feb\u9012\u2014\u2014\u4e0d\u662f\u9001\u4e0d\u5230\uff0c\u662f\u592a\u6d6a\u8d39<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn08\">\u516b\u3001\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u52bf\u65b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">AI\u5224\u65ad\u4f9d\u636e<\/th><\/tr><\/thead><tbody><tr><td>\u91c7\u6696\u8212\u9002\u5ea6<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u4f4e\u6e29\u5e73\u7a33\u8fd0\u884c\uff0c\u6e29\u5ea6\u5747\u5300<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5206\u6bb5\u71c3\u70e7\u4f4e\u9891\u8fd0\u884c\uff0c\u6e29\u5ea6\u5747\u5300<\/td><td>\u2b50\u2b50\u2b50 \u9891\u7e41\u542f\u505c\u5bfc\u81f4\u6e29\u5ea6\u5ffd\u51b7\u5ffd\u70ed<\/td><td>\u65b9\u6848\u4e00\/\u4e8c<\/td><td>\u9505\u7089\u542f\u505c\u95f4\u9694\u8d8a\u957f\uff0c\u5ba4\u6e29\u6ce2\u52a8\u8d8a\u5c0f\u3002\u65b9\u6848\u4e00\/\u4e8c\u6700\u5c0f\u8f93\u51fa3-4kW\u5339\u914d\u6052\u6e29\u8d1f\u8377\uff0c\u542f\u505c\u95f4\u9694\u8fdc\u957f\u4e8e\u65b9\u6848\u4e09<\/td><\/tr><tr><td>\u9759\u97f3\u6027<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5168\u9884\u6df7\u71c3\u70e7\u4f4e\u566a\u97f3<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u5206\u6bb5\u71c3\u70e7\u566a\u97f3\u4f4e\u4e8e\u5927\u6c14\u5f0f<\/td><td>\u2b50\u2b50\u2b50 \u666e\u901a\u7089\u542f\u505c\u566a\u97f3\u660e\u663e<\/td><td>\u65b9\u6848\u4e00<\/td><td>\u5168\u9884\u6df7\u71c3\u70e7\u6280\u672f\u566a\u97f3\u6700\u4f4e\uff0c\u65b9\u6848\u4e8c\u5206\u6bb5\u71c3\u70e7\u6b21\u4e4b\uff0c\u65b9\u6848\u4e09\u5927\u6c14\u5f0f\u71c3\u70e7\u566a\u97f3\u6700\u5927\u4e14\u542f\u505c\u9891\u7e41<\/td><\/tr><tr><td>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5339\u914d\u8fd0\u884c\uff0c\u4e0d\u9891\u7e41\u542f\u505c<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5339\u914d\u8fd0\u884c\uff0c\u4e0d\u9891\u7e41\u542f\u505c<\/td><td>\u2b50\u2b50 \u4e25\u91cd\u9891\u7e41\u542f\u505c\uff0c\u52a0\u901f\u8001\u5316<\/td><td>\u65b9\u6848\u4e00\/\u4e8c<\/td><td>\u9891\u7e41\u542f\u505c\u662f\u9505\u7089\u6545\u969c\u7684\u7b2c\u4e00\u8bf1\u56e0\u3002\u65b9\u6848\u4e00\/\u4e8c\u6700\u5c0f\u8f93\u51fa\u5339\u914d\u8d1f\u8377\uff0c\u65b9\u6848\u4e09\u6700\u5c0f\u8f93\u51fa8-10kW\u8fdc\u8d85\u9700\u6c42<\/td><\/tr><tr><td>\u667a\u80fd\u64cd\u4f5c<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 WiFi\u5ba4\u6e29\u8054\u52a8\uff0c\u8fbe\u6807\u81ea\u52a8\u505c<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 WiFi\u5ba4\u6e29\u8054\u52a8\uff0c\u8fbe\u6807\u81ea\u52a8\u505c<\/td><td>\u2b50\u2b50 \u57fa\u7840\u603b\u63a7\uff0c\u9760\u611f\u89c9\u624b\u52a8<\/td><td>\u65b9\u6848\u4e00\/\u4e8c<\/td><td>\u8054\u52a8\u63a7\u5236\u7701\u6c1410-25%\uff0c\u65e0\u9700\u4eba\u5de5\u5e72\u9884\u3002\u65b9\u6848\u4e00\/\u4e8c\u6807\u914d\u8054\u52a8\uff0c\u65b9\u6848\u4e09\u65e0\u8054\u52a8<\/td><\/tr><tr><td>\u9664\u6e7f\/\u5e72\u71e5\u611f<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u5730\u6696\u4f4e\u6e29\u8fd0\u884c\uff0c\u4e0d\u5e72\u71e5<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u5730\u6696\u4f4e\u6e29\u8fd0\u884c\uff0c\u4e0d\u5e72\u71e5<\/td><td>\u2b50\u2b50\u2b50 \u5730\u6696\u57fa\u7840\u4f53\u9a8c<\/td><td>\u6301\u5e73<\/td><td>\u5730\u6696\u672c\u8eab\u4e0d\u5439\u98ce\uff0c\u4e09\u79cd\u65b9\u6848\u5e72\u71e5\u611f\u5dee\u5f02\u4e0d\u5927<\/td><\/tr><tr><td>\u6e29\u5ea6\u5747\u5300\u6027<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 De32+De20\uff0c\u8fd1\u8fdc\u7aef\u5747\u5300<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 De32+De20\uff0c\u8fd1\u8fdc\u7aef\u5747\u5300<\/td><td>\u2b50\u2b50\u2b50 De25+De16\uff0c\u8fd1\u70ed\u8fdc\u51b7<\/td><td>\u65b9\u6848\u4e00\/\u4e8c<\/td><td>\u4e3b\u7ba1\u7ba1\u5f84\u51b3\u5b9a\u8fdc\u7aef\u6d41\u91cf\u3002\u65b9\u6848\u4e00\/\u4e8c\u91c7\u7528De32\u4e3b\u7ba1\uff0c\u6d41\u91cf\u662fDe25\u76842\u500d\u4ee5\u4e0a\uff0c\u6c34\u529b\u5e73\u8861\u66f4\u4f18<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn09\">\u4e5d\u3001\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u52bf\u65b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">AI\u5224\u65ad\u4f9d\u636e<\/th><\/tr><\/thead><tbody><tr><td>\u521d\u6295\u8d44\uff08\u5b9e\u4ed8\uff09<\/td><td>\u2b50\u2b50\u2b50 22,239\u5143<\/td><td>\u2b50\u2b50\u2b50\u2b50 15,939\u5143<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u7ea614,240-15,340\u5143<\/td><td>\u65b9\u6848\u4e09<\/td><td>\u65b9\u6848\u4e09\u521d\u6295\u8d44\u6700\u4f4e\uff0c\u65b9\u6848\u4e8c\u63a5\u8fd1\u65b9\u6848\u4e09\uff0c\u65b9\u6848\u4e00\u9ad8\u51fa\u7ea67,000-8,000\u5143<\/td><\/tr><tr><td>\u7cfb\u7edf\u80fd\u6548<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u70ed\u6548\u7387108%\uff0c\u4f4e\u6e29\u9ad8\u6548<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u5206\u6bb5\u71c3\u70e7\uff0c\u6548\u7387\u4f18\u4e8e\u666e\u901a\u7089<\/td><td>\u2b50\u2b50\u2b50 \u70ed\u6548\u738790%\uff0c\u9ad8\u6e29\u8fd0\u884c\u66f4\u4f4e<\/td><td>\u65b9\u6848\u4e00<\/td><td>\u51b7\u51dd\u7089\u4f4e\u6e29\u4f9b\u6c34\u65f6\u6548\u7387\u53ef\u8fbe108%\uff0c\u65b9\u6848\u4e8c\u5206\u6bb5\u71c3\u70e7\u6548\u7387\u4ecb\u4e8e\u4e24\u8005\u4e4b\u95f4\uff0c\u65b9\u6848\u4e09\u4f4e\u6e29\u8fd0\u884c\u65f6\u6548\u7387\u964d\u81f385%\u4ee5\u4e0b<\/td><\/tr><tr><td>\u5b89\u88c5\u590d\u6742\u5ea6<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u6807\u51c6\u5b89\u88c5+\u8054\u52a8\u8c03\u8bd5<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u6807\u51c6\u5b89\u88c5+\u8054\u52a8\u8c03\u8bd5<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u57fa\u7840\u5b89\u88c5+\u603b\u63a7<\/td><td>\u6301\u5e73<\/td><td>\u65b9\u6848\u4e00\/\u4e8c\u591a\u4e00\u6b65\u8054\u52a8\u8c03\u8bd5\uff0c\u4f46\u590d\u6742\u5ea6\u5dee\u5f02\u4e0d\u5927<\/td><\/tr><tr><td>\u7cfb\u7edf\u53ef\u9760\u6027<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5339\u914d\u8fd0\u884c\uff0c20\u5e74\u5bff\u547d<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u5339\u914d\u8fd0\u884c\uff0c10\u5e74\u5bff\u547d<\/td><td>\u2b50\u2b50 \u9891\u7e41\u542f\u505c\uff0c8\u5e74\u9700\u6362<\/td><td>\u65b9\u6848\u4e00<\/td><td>\u9891\u7e41\u542f\u505c\u662f\u9505\u7089\u6545\u969c\u9996\u56e0\u3002\u65b9\u6848\u4e00\u5bff\u547d20\u5e74\u65e0\u9700\u66f4\u6362\uff0c\u65b9\u6848\u4e8c10\u5e74\u63621\u6b21\uff0c\u65b9\u6848\u4e098\u5e74\u63622\u6b21<\/td><\/tr><tr><td>\u957f\u671f\u8fd0\u884c\u8d39<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u6708\u91c7\u6696500-650\u5143<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u6708\u91c7\u6696650-800\u5143<\/td><td>\u2b50\u2b50\u2b50 \u6708\u91c7\u6696900-1,200\u5143<\/td><td>\u65b9\u6848\u4e00<\/td><td>\u65b9\u6848\u4e00\u5e74\u8fd0\u884c\u8d39\u7ea62,300\u5143\uff0c\u65b9\u6848\u4e8c\u7ea63,000\u5143\uff0c\u65b9\u6848\u4e09\u7ea64,200\u5143\u3002\u65b9\u6848\u4e00\u6bd4\u65b9\u6848\u4e09\u5e74\u77011,900\u5143<\/td><\/tr><tr><td>\u4f7f\u7528\u5bff\u547d<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u745e\u7f8e20\u5e74\uff0c\u65e0\u9700\u66f4\u6362<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u66fc\u745e\u5fb710\u5e74\uff0c\u63621\u6b21<\/td><td>\u2b50\u2b50 \u666e\u901a\u70898\u5e74\uff0c\u63622\u6b21<\/td><td>\u65b9\u6848\u4e00<\/td><td>\u65b9\u6848\u4e0020\u5e74\u5185\u65e0\u9700\u66f4\u6362\u9505\u7089\uff1b\u65b9\u6848\u4e8c\u9700\u63621\u6b21\uff085,599\u5143\uff09\uff1b\u65b9\u6848\u4e09\u9700\u63622\u6b21\uff0816,000\u5143\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn10\">\u5341\u3001\u900f\u660e\u62a5\u4ef7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u4e00\uff1a\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\u7cfb\u7edf<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39(\u5143)<\/th><\/tr><\/thead><tbody><tr><td>\u51b7\u51dd\u7089<\/td><td>\u745e\u7f8eLL1GBQ19-CBX1-24\uff0820\u5e74\u5bff\u547d\uff09<\/td><td>1\u53f0<\/td><td>11,899<\/td><td>600<\/td><\/tr><tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u542b\u8054\u52a8\u63a7\u5236+\u4eba\u5de5\u670d\u52a1+\u56de\u586b\uff09<\/td><td>\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8<\/td><td>60\u33a1<\/td><td>10,740\uff08179\u5143\/\u33a1\u00d760\uff09<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e00\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><strong>22,639\u5143<\/strong><\/td><td><strong>600\u5143<\/strong><\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e00\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><strong>23,239\u5143<\/strong><\/td><\/tr><tr><td>\u4f1a\u5458\u6696\u901a\u62b5\u6263\u91d1<\/td><td><\/td><td><\/td><td><\/td><td><strong>-1,000\u5143<\/strong><\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e00\u5b9e\u4ed8<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><strong>22,239\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1a\u5982\u9009\u83f2\u65af\u66fcB1JG 25kW\u51b7\u51dd\u7089\uff0812\u5e74\u5bff\u547d\uff09\uff0c\u8bbe\u5907\u4ef713,597\u5143\uff0c\u65b9\u6848\u5408\u8ba1\u7ea624,937\u5143\uff0c\u5b9e\u4ed8\u7ea623,937\u5143\u3002\u5982\u9009\u66fc\u745e\u5fb7\u5c0f\u5361\u51b7\u51dd\u7089\uff0812\u5e74\u5bff\u547d\uff09\uff0c\u8bbe\u5907\u4ef710,900\u5143\uff0c\u65b9\u6848\u5408\u8ba1\u7ea622,240\u5143\uff0c\u5b9e\u4ed8\u7ea621,240\u5143\u3002\u745e\u7f8e\u4e0e\u83f2\u65af\u66fc\u5747\u4e3a\u5168\u9884\u6df7\u51b7\u51dd\u6280\u672f\uff0c\u70ed\u6548\u7387108%\uff0c\u6700\u5c0f\u8f93\u51fa3-4kW\uff0c\u54c1\u8d28\u76f8\u5f53\u3002\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u4e3a\u5e02\u573a\u901a\u914d\u7ade\u4e89\u8bbe\u5907\uff0c\u65e0\u5ef6\u4fdd\u3002\u745e\u7f8e\u51b7\u51dd\u7089\u53c2\u52a0\u9f99\u8109\u6696\u901a\u4f1a\u5458\uff0c\u63d0\u4f9b2000\u5143\u7684\u4f1a\u5458\u6298\u6263\uff0c\u9505\u7089\u8d28\u4fdd\u5ef6\u4fdd\u81f38\u5e74\uff08\u9700\u8981\u6ee1\u8db3\u6bcf\u5e74\u9505\u7089\u5185\u819b\u6e05\u6d17\u7ef4\u4fdd\u6761\u4ef6\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u4e8c\uff1a\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\u7cfb\u7edf<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39(\u5143)<\/th><\/tr><\/thead><tbody><tr><td>\u5206\u6bb5\u71c3\u70e7\u7089<\/td><td>\u66fc\u745e\u5fb7LL1PB26-Heidelberg Min.\uff0810\u5e74\u5bff\u547d\uff09<\/td><td>1\u53f0<\/td><td>5,599<\/td><td>600<\/td><\/tr><tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u542b\u8054\u52a8\u63a7\u5236+\u4eba\u5de5\u670d\u52a1+\u56de\u586b\uff09<\/td><td>\u5b9a\u523632-20\u4f1f\u661f\u963b\u6c27\u66fc\u745e\u5fb7\u8054\u52a8<\/td><td>60\u33a1<\/td><td>10,740\uff08179\u5143\/\u33a1\u00d760\uff09<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e8c\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><strong>16,339\u5143<\/strong><\/td><td><strong>600\u5143<\/strong><\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e8c\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><strong>16,939\u5143<\/strong><\/td><\/tr><tr><td>\u4f1a\u5458\u6696\u901a\u62b5\u6263\u91d1<\/td><td><\/td><td><\/td><td><\/td><td><strong>-1,000\u5143<\/strong><\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e8c\u5b9e\u4ed8<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><strong>15,939\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u4e09\uff1a\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u4ef7(\u5143)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39(\u5143)<\/th><\/tr><\/thead><tbody><tr><td>\u666e\u901a\u7089<\/td><td>\u83f2\u65af\u66fc\/\u535a\u4e16\/\u5a01\u80fd24kW\uff088\u5e74\u5bff\u547d\uff09<\/td><td>1\u53f0<\/td><td>\u7ea67,400-8,500<\/td><td>600<\/td><\/tr><tr><td>\u5730\u6696\u7cfb\u7edf\uff08\u5e02\u573a\u901a\u914d25-16\uff09<\/td><td>\u5e02\u573a\u901a\u914d99\u5143\/\u33a1<\/td><td>60\u33a1<\/td><td>5,940\uff0899\u5143\/\u33a1\u00d760\uff09<\/td><td>\u2014<\/td><\/tr><tr><td>\u603b\u63a7<\/td><td>\u57fa\u7840\u603b\u63a7<\/td><td>1\u5957<\/td><td>300<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u65b9\u6848\u4e09\u5408\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><strong>\u7ea614,240-15,340\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1a\u65b9\u6848\u4e09\u91c7\u7528\u5e02\u573a\u901a\u914d\u505a\u6cd5\u2014\u2014\u4e0d\u505a\u6c34\u529b\u8ba1\u7b97\u3001\u9ed8\u8ba4De25\u4e3b\u7ba1\u3001\u4e0d\u914d\u8054\u52a8\u63a7\u5236\u3002De25\u4e3b\u7ba1\u5bf9\u4e8e60\u33a1\u5730\u6696\u52c9\u5f3a\u591f\u7528\u4f46\u6d41\u91cf\u4f59\u91cf\u4e0d\u8db3\uff0c\u5f02\u7a0b\u5b89\u88c5\u5bb9\u6613\u8fd1\u7aef\u70ed\u8fdc\u7aef\u51b7\u3002\u65e0\u8054\u52a8\u63a7\u5236\u610f\u5473\u7740\u9505\u7089\u6309\u6c34\u6e29\u542f\u505c\u800c\u975e\u5ba4\u6e29\u2014\u2014\u5ba4\u6e29\u8fbe\u6807\u4e86\u9505\u7089\u8fd8\u5728\u70e7\uff0c\u65e0\u6548\u4ea7\u70ed\u6d6a\u8d39\u71c3\u6c14\u3002\u666e\u901a\u7089\u6700\u5c0f\u8f93\u51fa8-10kW\uff0c60\u33a1\u5730\u6696\u6052\u6e29\u4ec5\u97003kW\uff0c\u9891\u7e41\u542f\u505c\u662f\u5fc5\u7136\u7ed3\u679c\u3002\u8fd9\u4e9b\u9690\u60a3\u77ed\u671f\u5185\u4e0d\u5f71\u54cd\u4f7f\u7528\uff0c\u4f46\u957f\u671f\u71c3\u6c14\u8d39\u4f1a\u663e\u8457\u9ad8\u4e8e\u53e6\u5916\u4e24\u4e2a\u65b9\u6848\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e09\u65b9\u6848\u5b9e\u4ed8\u603b\u4ef7\u5bf9\u6bd4<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u603b\u4ef7<\/td><td>23,239\u5143<\/td><td>16,939\u5143<\/td><td>\u7ea614,240-15,340\u5143<\/td><\/tr><tr><td>\u4f1a\u5458\u62b5\u6263<\/td><td>-1,000\u5143<\/td><td>-1,000\u5143<\/td><td>\u2014<\/td><\/tr><tr><td><strong>\u5b9e\u4ed8<\/strong><\/td><td><strong>22,239\u5143<\/strong><\/td><td><strong>15,939\u5143<\/strong><\/td><td><strong>\u7ea614,240-15,340\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn11\">\u5341\u4e00\u300120\u5e74\u603b\u6295\u5165\u9010\u9879\u5dee\u989d\u8ba1\u7b97<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8ba1\u7b97\u524d\u63d0<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53d6\u503c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>60\u33a1<\/td><td><\/td><\/tr><tr><td>\u5e74\u91c7\u6696\u5929\u6570<\/td><td>120\u5929<\/td><td>\u6210\u90fd\u51ac\u5b63\u7ea64\u4e2a\u6708<\/td><\/tr><tr><td>\u7535\u4ef7<\/td><td>0.5\u5143\/\u5ea6<\/td><td>\u5c45\u6c11\u7528\u7535\u53c2\u8003\u4ef7<\/td><\/tr><tr><td>\u6c14\u4ef7<\/td><td>2.5\u5143\/\u65b9<\/td><td>\u6210\u90fd\u71c3\u6c14\u9636\u68af\u4ef7\u53d6\u4e2d<\/td><\/tr><tr><td>\u4f7f\u7528\u5e74\u9650<\/td><td>20\u5e74<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5e74\u8fd0\u884c\u8d39\u8ba1\u7b97<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6708\u91c7\u6696\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u91c7\u6696\u8d39\uff084\u4e2a\u6708\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u65b9\u6848\u4e00\uff08\u51b7\u51dd\u7089+\u4f4e\u6e29\u9ad8\u6548+\u8054\u52a8\uff09<\/td><td>500-650\u5143<\/td><td>\u7ea62,300\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e8c\uff08\u5206\u6bb5\u71c3\u70e7+\u8054\u52a8\uff09<\/td><td>650-800\u5143<\/td><td>\u7ea63,000\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u65e0\u8054\u52a8+\u9891\u7e41\u542f\u505c\uff09<\/td><td>900-1,200\u5143<\/td><td>\u7ea64,200\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u8ba1\u7b97\u8fc7\u7a0b\uff1a60\u33a1\u00d750W\/\u33a1=3kW\u6052\u6e29\u8d1f\u8377\u3002\u65b9\u6848\u4e00\u51b7\u51dd\u7089\u4f4e\u6e29\u9ad8\u6548\u8fd0\u884c\uff0c\u6708\u7528\u6c14\u7ea6200-260m\u00b3\u00d72.5\u5143=500-650\u5143\uff1b\u65b9\u6848\u4e8c\u5206\u6bb5\u71c3\u70e7\u7089\u6548\u7387\u7565\u4f4e\u4e8e\u51b7\u51dd\u7089\uff0c\u6708\u7528\u6c14\u7ea6260-320m\u00b3\u00d72.5\u5143=650-800\u5143\uff1b\u65b9\u6848\u4e09\u666e\u901a\u7089\u6548\u738790%+\u9891\u7e41\u542f\u505c\u635f\u8017\uff0c\u6708\u7528\u6c14\u7ea6360-480m\u00b3\u00d72.5\u5143=900-1,200\u5143\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9505\u7089\u66f4\u6362\u8d39\uff0820\u5e74\u5185\uff09<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u5bff\u547d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66f4\u6362\u6b21\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66f4\u6362\u8d39\u7528<\/th><\/tr><\/thead><tbody><tr><td>\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089\uff09<\/td><td>20\u5e74<\/td><td>0\u6b21<\/td><td>0\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\uff09<\/td><td>10\u5e74<\/td><td>1\u6b21\uff08\u7b2c11\u5e74\uff09<\/td><td>5,599\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089\uff0c\u65e0\u4fdd\u517b\uff09<\/td><td>8\u5e74<\/td><td>2\u6b21\uff08\u7b2c9\u5e74+\u7b2c17\u5e74\uff09<\/td><td>8,000\u00d72=16,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>20\u5e74\u603b\u6295\u5165\u6c47\u603b<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8d39\u7528\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u521d\u6295\u8d44\uff08\u5b9e\u4ed8\uff09<\/td><td>22,239\u5143<\/td><td>15,939\u5143<\/td><td>\u7ea614,240-15,340\u5143<\/td><\/tr><tr><td>20\u5e74\u91c7\u6696\u8d39<\/td><td>2,300\u00d720=46,000\u5143<\/td><td>3,000\u00d720=60,000\u5143<\/td><td>4,200\u00d720=84,000\u5143<\/td><\/tr><tr><td>\u9505\u7089\u66f4\u6362\u8d39<\/td><td>0\u5143<\/td><td>5,599\u5143<\/td><td>16,000\u5143<\/td><\/tr><tr><td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td><td><strong>68,239\u5143<\/strong><\/td><td><strong>81,538\u5143<\/strong><\/td><td><strong>\u7ea6114,240-115,340\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5dee\u989d\u5bf9\u6bd4<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5dee\u989d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7ed3\u8bba<\/th><\/tr><\/thead><tbody><tr><td>\u65b9\u6848\u4e00 vs \u65b9\u6848\u4e09<\/td><td>115,340-68,239=47,101\u5143<\/td><td>\u65b9\u6848\u4e00\u6bd4\u65b9\u6848\u4e09\u7701\u7ea647,000\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e8c vs \u65b9\u6848\u4e09<\/td><td>115,340-81,538=33,802\u5143<\/td><td>\u65b9\u6848\u4e8c\u6bd4\u65b9\u6848\u4e09\u7701\u7ea634,000\u5143<\/td><\/tr><tr><td>\u65b9\u6848\u4e00 vs \u65b9\u6848\u4e8c<\/td><td>81,538-68,239=13,299\u5143<\/td><td>\u65b9\u6848\u4e00\u6bd4\u65b9\u6848\u4e8c\u7701\u7ea613,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56de\u672c\u5468\u671f\u8ba1\u7b97<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u521d\u6295\u8d44\u5dee\u989d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u8fd0\u884c\u8d39\u5dee\u989d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66f4\u6362\u8d39\u5dee\u989d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u56de\u672c\u5468\u671f<\/th><\/tr><\/thead><tbody><tr><td>\u65b9\u6848\u4e00 vs \u65b9\u6848\u4e09<\/td><td>22,239-15,340\u22486,900\u5143<\/td><td>4,200-2,300=1,900\u5143\/\u5e74<\/td><td>0-16,000=-16,000\u5143<\/td><td>\u65b9\u6848\u4e00\u521d\u6295\u8d44\u867d\u9ad8\uff0c\u4f46\u514d\u4e8616,000\u5143\u66f4\u6362\u8d39\uff0c\u5df2\u76f4\u63a5\u7701\u94b1<\/td><\/tr><tr><td>\u65b9\u6848\u4e00 vs \u65b9\u6848\u4e8c<\/td><td>22,239-15,939=6,300\u5143<\/td><td>3,000-2,300=700\u5143\/\u5e74<\/td><td>0-5,599=-5,599\u5143<\/td><td>(6,300+5,599)\u00f7700\u224817\u5e74\uff08\u4f46\u65b9\u6848\u4e00\u5bff\u547d20\u5e74\u65e0\u66f4\u6362\u8d39\u4f18\u52bf\u5728\u957f\u671f\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u4e00\uff08\u745e\u7f8e\u51b7\u51dd\u7089+\u8282\u80fd\u7cfb\u7edf\uff0920\u5e74\u603b\u6295\u5165\u6700\u4f4e\uff0c\u6bd4\u65b9\u6848\u4e09\u7701\u7ea647,000\u5143\uff0c\u6bd4\u65b9\u6848\u4e8c\u7701\u7ea613,000\u5143\u3002\u745e\u7f8e\u51b7\u51dd\u7089\u5bff\u547d20\u5e74\uff0c20\u5e74\u5185\u65e0\u9700\u66f4\u6362\u9505\u7089\uff0c\u8fd9\u662f\u5b83\u6700\u5927\u7684\u957f\u671f\u4f18\u52bf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u4e8c\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7+\u8282\u80fd\u7cfb\u7edf\uff09\u9002\u5408\u9884\u7b97\u6709\u9650\u4f46\u60f3\u83b7\u5f97\u63a5\u8fd1\u65b9\u6848\u4e00\u957f\u671f\u8282\u80fd\u6548\u679c\u7684\u5ba2\u6237\u3002\u521d\u6295\u8d44\u4ec515,939\u5143\uff0c\u6bd4\u65b9\u6848\u4e00\u4f4e6,300\u5143\uff0c\u6bd4\u65b9\u6848\u4e09\u53ea\u9ad8\u7ea61,000-1,700\u5143\uff0c\u4f4620\u5e74\u603b\u6295\u5165\u6bd4\u65b9\u6848\u4e09\u7701\u7ea634,000\u5143\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u4e09\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09\u521d\u6295\u8d44\u6700\u4f4e\u4f46\u957f\u671f\u8d39\u7528\u6700\u9ad8\u3002\u666e\u901a\u7089\u65e0\u4fdd\u517b\u5bff\u547d\u4ec58\u5e74\uff0c20\u5e74\u5185\u9700\u66f4\u63622\u6b21\u9505\u7089\uff0c\u52a0\u4e0a\u65e0\u8054\u52a8\u63a7\u5236\u5bfc\u81f4\u7684\u9891\u7e41\u542f\u505c\u548c\u9ad8\u71c3\u6c14\u8d39\uff0c20\u5e74\u603b\u6295\u5165\u662f\u65b9\u6848\u4e00\u7684\u8fd11.7\u500d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f \u4ee5\u4e0a\u4e3a\u57fa\u4e8e\u6807\u51c6\u7684\u4f30\u7b97\u503c\uff0c\u5b9e\u9645\u8d39\u7528\u53d7\u4f7f\u7528\u4e60\u60ef\u3001\u80fd\u6e90\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\u3002\u65b9\u6848\u4e00\/\u65b9\u6848\u4e8c\/\u65b9\u6848\u4e09\u5404\u6709\u7279\u70b9\uff0c\u60a8\u53ef\u6839\u636e\u81ea\u8eab\u5bf9\u521d\u6295\u8d44\u3001\u957f\u671f\u8d39\u7528\u3001\u7cfb\u7edf\u7a33\u5b9a\u6027\u7684\u4f18\u5148\u7ea7\u5224\u65ad\u9009\u62e9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"\u5ba2\u6237\u6848\u4f8b\">\u5ba2\u6237\u6848\u4f8b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6848\u4f8b\u7c7b\u578b<\/th><th>\u4ee3\u8868\u9879\u76ee<\/th><th>\u7cfb\u7edf\u7c7b\u578b<\/th><th>\u5ba2\u6237\u53cd\u9988\u6458\u8981<\/th><\/tr><\/thead><tbody><tr><td>\u5c0f\u6237\u578b\u00b7\u51b7\u51dd\u7089\u5730\u6696<\/td><td>\u5468\u8001\u5e08\u00b793\u33a1\u5e73\u5c42<\/td><td>\u745e\u7f8e\u51b7\u51dd\u7089+De32+\u8054\u52a8<\/td><td>\"\u4ece\u4ea7\u54c1\u5230\u5b89\u88c5\u5168\u7a0b\u8d85\u51fa\u9884\u671f\"<\/td><\/tr><tr><td>\u522b\u5885\u00b7\u5168\u5c4b\u8212\u9002\u7cfb\u7edf<\/td><td>\u674e\u603b\u00b7170\u33a1\u91c7\u6696\u9762\u79ef\u53e0\u62fc<\/td><td>\u65e5\u7acb\u5c0a\u777f504+\u53cc\u51b7\u51dd\u7089+\u5730\u6696<\/td><td>\"\u5730\u6696\u6708\u8d39\u4e0d\u5230500\u5143\uff0c\u5168\u5c0f\u533a\u6700\u4f4e\"<\/td><\/tr><tr><td>\u4e94\u6052\u00b7\u6c34\u6c1f\u590d\u5408<\/td><td>\u6881\u603b\u00b7\u5929\u5e9c\u516c\u9986\u522b\u5885<\/td><td>\u4e24\u8054\u4f9b\u5730\u6696+\u65b0\u98ce<\/td><td>\"\u6ee1\u610f\u5ea610\u5206\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn12\">\u5341\u4e8c\u3001\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u627f\u8bfa\u9879<\/th><th>\u5185\u5bb9<\/th><th>\u5b9e\u4f8b\u5370\u8bc1<\/th><\/tr><\/thead><tbody><tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><td>\u6bcf\u4f4d\u5ba2\u6237\u5747\u4eab\u6b64\u670d\u52a1\uff0c\u6863\u6848\u53ef\u67e5<\/td><\/tr><tr><td>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u65b9\u6848<\/td><td>\u672c\u65b9\u6848\u4e66\u5373\u4e3a\u5b9e\u4f8b<\/td><\/tr><tr><td>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><td>\u6e56\u4e0e\u767d\u7ba1\u8001\u5e08\u9879\u76ee\u7cbe\u5de5\u516d\u6b65\u6cd5\u5168\u7a0b\u7167\u7247\u5b58\u6863<\/td><\/tr><tr><td>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><td>\u672c\u65b9\u6848\u9010\u9879\u5217\u660e\uff0c\u53ef\u5bf9\u7167<\/td><\/tr><tr><td>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><td>\u5165\u4f1a\u5458\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><td>\u6881\u603b\u9879\u76ee\u5df2\u5b9e\u73b0\u5e74\u5ea6\u56de\u8bbf+\u4f18\u5316\u5efa\u8bae\u95ed\u73af<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn13\">\u5341\u4e09\u3001\u7b7e\u7ea6\u540e\u60a8\u5c06\u62e5\u6709\u2014\u2014\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9009\u62e9\u9f99\u8109\u6696\u901a\uff0c\u60a8\u83b7\u5f97\u7684\u4e0d\u4ec5\u662f\u4e00\u5957\u8bbe\u5907\uff0c\u66f4\u662f\u4e00\u4efd<a href=\"https:\/\/longmai-nt.com\/?page_id=982\"><strong>\u53ef\u8ffd\u6eaf\u3001\u53ef\u9a8c\u8bc1\u3001\u53ef\u89c6\u5316<\/strong>\u7684\u5b8c\u6574\u670d\u52a1\u6863\u6848<\/a>\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"131-\u60a8\u7684\u4e13\u5c5e\u6863\u6848\u5305\u542b\">13.1 \u60a8\u7684\u4e13\u5c5e\u6863\u6848\u5305\u542b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6863\u6848\u5185\u5bb9<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\ud83d\udcf8 \u65bd\u5de5\u5168\u6d41\u7a0b\u7167\u7247<\/td><td>\u4ece\u9690\u853d\u5de5\u7a0b\u5230\u7ae3\u5de5\u9a8c\u6536\uff0c\u6bcf\u4e2a\u5173\u952e\u8282\u70b9\u5747\u6709\u7167\u7247\u5b58\u6863<\/td><\/tr><tr><td>\ud83d\udccb \u8bbe\u5907\u6e05\u5355\u4e0e\u9a8c\u6536\u5355<\/td><td>\u8bbe\u5907\u578b\u53f7\u3001\u5e8f\u5217\u53f7\u3001\u5b89\u88c5\u4f4d\u7f6e\u5168\u7a0b\u8bb0\u5f55<\/td><\/tr><tr><td>\ud83d\udcca 10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u80fd\u8017\u6570\u636e\u91c7\u96c6\uff0c\u51fa\u5177\u5e74\u5ea6\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><\/tr><tr><td>\ud83d\udd27 \u552e\u540e\u8bb0\u5f55<\/td><td>\u6bcf\u6b21\u7ef4\u4fdd\u3001\u68c0\u6d4b\u3001\u6e05\u6d17\u5747\u6709\u8be6\u7ec6\u8bb0\u5f55<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"132-\u4e0e\u60a8\u6237\u578b\u76f8\u8fd1\u7684\u771f\u5b9e\u5ba2\u6237\u6863\u6848\u6458\u8981\">13.2 \u4e0e\u60a8\u6237\u578b\u76f8\u8fd1\u7684<a href=\"https:\/\/longmai-nt.com\/?page_id=599\">\u771f\u5b9e\u5ba2\u6237\u6863\u6848<\/a>\u6458\u8981<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5468\u8001\u5e08 \u00b7 \u5e73\u5c42 \u00b7 \u91c7\u6696\u9762\u79ef\u7ea693\u33a1 \u00b7 \u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf<\/strong><br>\u7b7e\u7ea6\u65f6\u95f4\uff1a2025\u5e74 | \u9500\u552e\u987e\u95ee\uff1a\u4f59\u7231\u82f1<br>\u914d\u7f6e\uff1a\u745e\u7f8e\u51b7\u51dd\u708924kW + De32\u4e3b\u7ba1 + De20\u963b\u6c27\u7ba1 + \u66fc\u745e\u5fb7WiFi\u8054\u52a8<br>\u5ba2\u6237\u539f\u8bdd\uff1a<em>\"\u88c5\u4fee\u9009\u6696\u901a\u8bbe\u5907\u505a\u4e86\u8d85\u591a\u529f\u8bfe\uff0c\u6700\u7ec8\u6572\u5b9a\u9f99\u8109\u2026\u2026\u4ece\u4ea7\u54c1\u5230\u5b89\u88c5\u5168\u7a0b\u8d85\u51fa\u9884\u671f\uff0c\u5fc5\u987b\u5b9e\u540d\u597d\u8bc4\uff01\"<\/em><br>\u6863\u6848\u5305\u542b\uff1a\u7cbe\u5de5\u516d\u6b65\u6cd5\u65bd\u5de5\u7167\u7247\u96c6\u3001\u8c03\u8bd5\u4ea4\u4ed8\u9a8c\u6536\u5355\u300110\u5e74\u80fd\u8017\u8ddf\u8e2a\u57fa\u51c6\u6570\u636e<br>\u6863\u6848\u94fe\u63a5\uff1a<a href=\"http:\/\/longmai-nt.com\/?page_id=982\">\u8bf7\u70b9\u51fb\u67e5\u770b\u8fd9\u91cc\u2192<\/a><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"133-\u670d\u52a1\u6d41\u7a0b\u95ed\u73af\">13.3 \u670d\u52a1\u6d41\u7a0b\u95ed\u73af<\/h3>\n\n\n\n<pre class=\"wp-block-code\"><code>\u9700\u6c42\u5bf9\u9f50 \u2192 \u65b9\u6848\u9009\u62e9 \u2192 \u7b7e\u7ea6 \u2192 \u65bd\u5de5\u6267\u884c\uff08\u7cbe\u5de56\u6b65\u6cd5+2\uff09\u2192 \u4ea4\u4ed8\u6559\u5b66 \n\u2192 10\u5e74\u80fd\u8017\u8ddf\u8e2a \u2192 \u5e74\u5ea6\u56de\u8bbf \u2192 \u4f18\u5316\u5efa\u8bae \u2192 20\u5e74\u670d\u52a1\u4fdd\u969c<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ece\u65bd\u5de5\u5f00\u59cb\uff0c\u5c31\u5c5e\u4e8e\u95ed\u73af\u3002\u60a8\u7684\u6863\u6848\u4ece\u7b7e\u7ea6\u90a3\u4e00\u523b\u8d77\u6301\u7eed\u66f4\u65b0\uff0c<strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<\/strong>\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn14\">\u5341\u56db\u300110\u5e74\u80fd\u6e90\u4fdd\u969c\u9080\u8bf7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\"10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\"\u2014\u2014\u4e0d\u662f\u8425\u9500\u6d3b\u52a8\uff0c\u662f\u5199\u8fdb\u60a8\u5ba2\u6237\u6863\u6848\u768410\u5e74\u670d\u52a1\u627f\u8bfa\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"141-\u4e24\u7ec4\u600e\u4e48\u9009\">14.1 \u4e24\u7ec4\u600e\u4e48\u9009\uff1f<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ec4\u522b<\/th><th>\u540d\u79f0<\/th><th>\u9002\u5408\u8c01<\/th><th>\u60a8\u7684\u65b9\u6848\u5bf9\u5e94<\/th><\/tr><\/thead><tbody><tr><td>A\u7ec4<\/td><td>\u5bf9\u7167\u7ec4<\/td><td>\u6709\u81ea\u5df1\u7684\u60f3\u6cd5\uff0c\u90e8\u5206\u8ba4\u53ef\u6211\u4eec\u7684\u8bbe\u8ba1<\/td><td>\u65b9\u6848\u4e8c\uff08\u666e\u901a\u7089+\u5e02\u573a\u901a\u914d\uff09<\/td><\/tr><tr><td>B\u7ec4<\/td><td>\u5b9e\u9a8c\u7ec4<\/td><td>\u5b8c\u5168\u8ba4\u53ef\u6211\u4eec\u7684\u7cfb\u7edf\u8bbe\u8ba1<\/td><td>\u65b9\u6848\u4e00\uff08\u51b7\u51dd\u7089+\u8282\u80fd\u7cfb\u7edf\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"142-b\u7ec4\u4e13\u5c5e\u798f\u5229\u63a8\u8350\u60a8\u9009\u62e9\u7684\u65b9\u6848\u4e00\">14.2 B\u7ec4\u4e13\u5c5e\u798f\u5229\uff08\u63a8\u8350\u60a8\u9009\u62e9\u7684\u65b9\u6848\u4e00\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6743\u76ca<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u514d\u8d39\u8054\u52a8\u63a7\u5236\u5668<\/td><td>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8\uff08\u4ef7\u503c980\u5143\uff09\uff0c\u5df2\u5305\u542b\u5728\u65b9\u6848\u4e00\u4e2d<\/td><\/tr><tr><td>10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><\/tr><tr><td>\u540c\u6237\u578b\u8131\u654f\u5bf9\u6807<\/td><td>\"\u6211\u5bb6\u8fd9\u4e2a\u80fd\u8017\uff0c\u7b97\u9ad8\u8fd8\u662f\u7b97\u4f4e\uff1f\"\u2014\u2014\u63d0\u4f9b\u540c\u6237\u578b\u5bf9\u6bd4\u6570\u636e<\/td><\/tr><tr><td>\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae<\/td><td>\u6570\u636e\u663e\u793a\u6709\u4f18\u5316\u7a7a\u95f4\u65f6\uff0c\u4e3b\u52a8\u7ed9\u51fa\u5efa\u8bae<\/td><\/tr><tr><td>\u5e74\u5ea6\u56de\u8bbf<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u4e3b\u52a8\u56de\u8bbf\u7528\u6c14\u91cf\uff0c\u51fa\u5177\u5e74\u5ea6\u80fd\u8017\u62a5\u544a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"143-10\u5e74\u8ddf\u8e2a\u56db\u4e2a\u8def\u6807\">14.3 10\u5e74\u8ddf\u8e2a\u00b7\u56db\u4e2a\u8def\u6807<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9636\u6bb5<\/th><th>\u65f6\u95f4<\/th><th>\u4ea4\u4ed8\u7269<\/th><\/tr><\/thead><tbody><tr><td>\ud83d\udcd8 \u57fa\u51c6\u5efa\u7acb\u671f<\/td><td>\u7b2c1\u5e74<\/td><td>\u300a\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848\u300b\u2014\u2014\u8bbe\u8ba1\u8d1f\u8377\u3001\u5b9e\u6d4b\u80fd\u6548\u3001\u5173\u952e\u90e8\u4ef6\u6570\u636e<\/td><\/tr><tr><td>\ud83d\udcc8 \u6548\u679c\u9a8c\u8bc1\u671f<\/td><td>\u7b2c3\u5e74<\/td><td>\u300a3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a\u300b\u2014\u2014\u4e0e\u540c\u7c7b\u6237\u578b\u521d\u6b65\u5bf9\u6bd4<\/td><\/tr><tr><td>\ud83d\udd27 \u6df1\u5ea6\u89e3\u6790\u671f<\/td><td>\u7b2c5\u5e74<\/td><td>\u300a\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\u300b\u2014\u2014\u90e8\u4ef6\u635f\u8017\u8bc4\u4f30\u3001\u80fd\u6548\u8870\u51cf\u5206\u6790<\/td><\/tr><tr><td>\ud83c\udfaf \u627f\u8bfa\u5151\u73b0\u671f<\/td><td>\u7b2c10\u5e74<\/td><td>\u300a10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u300b\u2014\u2014\u9a8c\u8bc1\u8bbe\u8ba1\u627f\u8bfa<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"144-\u6838\u5fc3\u539f\u5219\">14.4 \u6838\u5fc3\u539f\u5219<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4e0d\u516c\u5f00<\/strong>\uff1a\u60a8\u7684\u539f\u59cb\u6570\u636e\u4e0d\u5bf9\u5916\u516c\u5f00<\/li>\n\n\n\n<li><strong>\u4e0d\u6bd4\u8f83<\/strong>\uff1a\u4e0d\u62ff\u60a8\u7684\u6570\u636e\u4e0e\u5176\u4ed6\u5ba2\u6237\u6bd4\u8f83<\/li>\n\n\n\n<li><strong>\u4e0d\u8bc4\u5224<\/strong>\uff1a\u4e0d\u56e0\u60a8\u7684\u9009\u62e9\u4e0d\u540c\u800c\u533a\u522b\u5bf9\u5f85<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"http:\/\/longmai-nt.com\/?page_id=518\">\ud83d\udccc \u8be6\u60c5\u8bf7\u53c2\u9605\uff1a\u9f99\u8109\u6696\u901a\u00b710\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u9080\u8bf7 \u2192 <\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn15\">\u5341\u4e94\u3001\u4fe1\u4efb\u9875<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"\u5b98\u65b9\u6388\u6743\">\u5b98\u65b9\u6388\u6743<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u4e3a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u3001\u83f2\u65af\u66fc\/\u745e\u7f8e\u9505\u7089\u5b98\u65b9\u6388\u6743\u7ecf\u9500\u5546\uff0c\u6388\u6743\u8d44\u8d28\u53ef\u901a\u8fc7\u5404\u54c1\u724c\u5b98\u65b9\u5ba2\u670d\u70ed\u7ebf\u9a8c\u8bc1\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"\u5ba2\u6237\u6848\u4f8b\">\u5ba2\u6237\u6848\u4f8b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6848\u4f8b\u7c7b\u578b<\/th><th>\u4ee3\u8868\u9879\u76ee<\/th><th>\u7cfb\u7edf\u7c7b\u578b<\/th><th>\u5ba2\u6237\u53cd\u9988\u6458\u8981<\/th><\/tr><\/thead><tbody><tr><td>\u5c0f\u6237\u578b\u00b7\u51b7\u51dd\u7089\u5730\u6696<\/td><td>\u5468\u8001\u5e08\u00b793\u33a1\u5e73\u5c42<\/td><td>\u745e\u7f8e\u51b7\u51dd\u7089+De32+\u8054\u52a8<\/td><td>\"\u4ece\u4ea7\u54c1\u5230\u5b89\u88c5\u5168\u7a0b\u8d85\u51fa\u9884\u671f\"<\/td><\/tr><tr><td>\u522b\u5885\u00b7\u5168\u5c4b\u8212\u9002\u7cfb\u7edf<\/td><td>\u8f9b\u603b\u00b7600\u33a1\u522b\u5885<\/td><td>\u65e5\u7acb\u5c0a\u777f504+\u53cc\u51b7\u51dd\u7089+\u5730\u6696<\/td><td>\"\u5730\u6696\u6708\u8d39\u4e0d\u52302000\u5143\uff0c\u90bb\u5c455000-6000\u5143\"<\/td><\/tr><tr><td>\u4e94\u6052\u00b7\u6c34\u6c1f\u590d\u5408<\/td><td>\u6881\u603b\u00b7\u5929\u5e9c\u516c\u9986\u522b\u5885<\/td><td>\u6c34\u5885\u9002VF+\u667a\u4eab+\u65b0\u98ce<\/td><td>\"\u6ee1\u610f\u5ea610\u5206\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn16\">\u5341\u516d\u3001\u6743\u5a01\u80cc\u4e66\u9875<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u80cc\u4e66\u7c7b\u578b<\/th><th>\u5185\u5bb9<\/th><th>\u9a8c\u8bc1\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td>\u56fd\u6807\u6761\u6b3e<\/td><td>GB 50736-2012\uff1a\u6210\u90fd\u590f\u70ed\u51ac\u51b7\u5730\u533a\u8bbe\u8ba1\u70ed\u8d1f\u837750-80W\/\u33a1<\/td><td>\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf\u53ef\u67e5<\/td><\/tr><tr><td>\u56fd\u6807\u6761\u6b3e<\/td><td>JGJ 142-2012\uff1a\u4f4e\u6e29\u4f9b\u6c34\u5730\u6696\u7cfb\u7edf\u7ba1\u5f84\u2265De20\uff0c\u4e3b\u7ba1\u2265De32<\/td><td>\u540c\u4e0a<\/td><\/tr><tr><td>\u56fd\u6807\u6761\u6b3e<\/td><td>GB 20665-2015\uff1a\u51b7\u51dd\u7089\u70ed\u6548\u7387\u226598%\u4e3a\u4e00\u7ea7\u80fd\u6548\uff0c\u666e\u901a\u7089\u226589%\u4e3a\u4e8c\u7ea7<\/td><td>\u540c\u4e0a<\/td><\/tr><tr><td>\u5382\u5bb6\u6280\u672f\u624b\u518c<\/td><td>\u83f2\u65af\u66fc\/\u745e\u7f8e\u51b7\u51dd\u7089\u8bbe\u8ba1\u624b\u518c\uff1a\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u3001\u4f4e\u6e29\u8fd0\u884c\u53c2\u6570<\/td><td>\u54c1\u724c\u5b98\u65b9\u6280\u672f\u652f\u6301\u53ef\u9a8c\u8bc1<\/td><\/tr><tr><td>\u54c1\u8d28\u8ba4\u8bc1<\/td><td>\u6d77\u4fe1\u65e5\u7acb\u9ec4\u5c9b\u5de5\u5382\u2014\u2014\u5168\u7403\u9996\u5ea7\u591a\u8054\u673a\u4e2d\u592e\u7a7a\u8c03\u706f\u5854\u5de5\u5382<\/td><td>\u4e16\u754c\u7ecf\u6d4e\u8bba\u575b\u5b98\u7f51\u53ef\u67e5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn17\">\u5341\u4e03\u3001\u5b89\u88c5\u4e0e\u552e\u540e\u4fdd\u969c\u7684\u53ef\u89c6\u5316\u6d41\u7a0b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"171-\u5b89\u88c5\u6d41\u7a0b\u7cbe\u5de56\u6b65\u6cd52\">17.1 \u5b89\u88c5\u6d41\u7a0b\uff08\u7cbe\u5de56\u6b65\u6cd5+2\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9636\u6bb5<\/th><th>\u5de5\u5e8f<\/th><th>\u5173\u952e\u8282\u70b9<\/th><th>\u9a8c\u6536\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c1\u6b65<\/td><td>\u73b0\u573a\u52d8\u6d4b<\/td><td>\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u7ba1\u8def\u8d70\u5411\u3001\u5206\u6c34\u7bb1\u4f4d\u7f6e<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\u7b2c2\u6b65<\/td><td>\u8bbe\u8ba1\u51fa\u56fe<\/td><td>\u5730\u6696\u76d8\u7ba1\u56fe\u7eb8\u3001\u5206\u96c6\u6c34\u5668\u5e03\u7f6e\u56fe<\/td><td>\u7b26\u5408JGJ 142-2012\u89c4\u8303<\/td><\/tr><tr><td>\u7b2c3\u6b65<\/td><td>\u9690\u853d\u5de5\u7a0b\u65bd\u5de5<\/td><td>\u76d8\u7ba1\u94fa\u8bbe\u3001\u4fdd\u6e29\u5c42\u3001\u6253\u538b\u6d4b\u8bd5\uff088-10bar\u4fdd\u538b\uff09<\/td><td>\u4e09\u9053\u5bc6\u5c01\u5de5\u827a\uff0c\u5168\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><tr><td>\u7b2c4\u6b65<\/td><td>\u7cfb\u7edf\u5b89\u88c5<\/td><td>\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u3001\u4e3b\u7ba1\u8fde\u63a5\u3001\u8054\u52a8\u63a7\u5236\u5b89\u88c5<\/td><td>\u4fdd\u538b24h\u4e0d\u964d<\/td><\/tr><tr><td>\u7b2c5\u6b65<\/td><td>\u7cfb\u7edf\u8c03\u8bd5<\/td><td>\u8865\u6c34\u81f31.2-1.5bar\uff0c\u6d4b\u8bd5\u8054\u52a8\u529f\u80fd\uff0c\u8bbe\u5b9a\u4f9b\u6c34\u6e29\u5ea635-45\u2103<\/td><td>\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c\u6b63\u5e38<\/td><\/tr><tr><td>\u7b2c6\u6b65<\/td><td>\u7ae3\u5de5\u9a8c\u6536<\/td><td>\u5404\u623f\u95f4\u6e29\u5ea6\u6d4b\u8bd5\u3001APP\u63a7\u5236\u6f14\u793a\u3001\u9a8c\u6536\u5355\u7b7e\u5b57<\/td><td>\u9a8c\u6536\u7ed3\u8bba\u7559\u6863<\/td><\/tr><tr><td>+1<\/td><td>\u4ea4\u4ed8\u6559\u5b66<\/td><td>\u9505\u7089\u64cd\u4f5c\u3001\u6e29\u63a7\u5668\u4f7f\u7528\u3001APP\u8fdc\u7a0b\u63a7\u5236\u3001\u7ef4\u62a4\u8981\u70b9<\/td><td>\u4e1a\u4e3b\u786e\u8ba4\u638c\u63e1<\/td><\/tr><tr><td>+2<\/td><td>\u552e\u540e\u4fdd\u969c<\/td><td>\u8bbe\u5907\u8d28\u4fdd\u3001\u5de5\u7a0b\u8d28\u4fdd\u3001\u4e09\u65b9\u8054\u4fdd\u3001\u5e74\u5ea6\u7ef4\u4fdd<\/td><td>\u6301\u7eed10\u5e74+<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"172-\u4ea4\u4ed8\u6559\u5b66\u8981\u70b9\">17.2 \u4ea4\u4ed8\u6559\u5b66\u8981\u70b9<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u64cd\u4f5c\u9879<\/th><th>\u8bbe\u5b9a\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td>\u9505\u7089\u6c34\u6e29\u8bbe\u7f6e<\/td><td>35-45\u2103\uff08\u4f4e\u6e29\u8fd0\u884c\uff0c\u4e0d\u8d85\u8fc750\u2103\uff09<\/td><\/tr><tr><td>\u5ba4\u6e29\u8bbe\u7f6e<\/td><td>\u5efa\u8bae18-22\u2103\uff0c\u6bcf\u964d\u4f4e1\u2103\u7701\u6c145-10%<\/td><\/tr><tr><td>\u9996\u6b21\u5347\u6e29<\/td><td>\u5206\u6b65\u5347\u6e29\uff0c\u6bcf\u5929\u22645\u2103\uff0c\u907f\u514d\u5730\u9762\u5f00\u88c2<\/td><\/tr><tr><td>\u77ed\u671f\u79bb\u5bb6<\/td><td>\u8c03\u4f4e\u5ba4\u6e29\u81f314-16\u2103\uff0c\u4e0d\u8981\u5b8c\u5168\u5173\u95ed<\/td><\/tr><tr><td>\u957f\u671f\u79bb\u5bb6<\/td><td>\u4fdd\u6301\u9505\u7089\u901a\u7535\u901a\u6c14\uff0c\u542f\u7528\u9632\u51bb\u6a21\u5f0f<\/td><\/tr><tr><td>\u7cfb\u7edf\u8865\u6c34<\/td><td>\u6c34\u538b\u4f4e\u4e8e1.0bar\u65f6\u8865\u6c34\u81f31.2-1.5bar<\/td><\/tr><tr><td>\u9505\u7089\u4fdd\u517b<\/td><td>1-2\u5e74\u6e05\u6d17\u71c3\u70e7\u5ba4\u3001\u98ce\u673a\u53f6\u8f6e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"173-\u552e\u540e\u4fdd\u969c\">17.3 \u552e\u540e\u4fdd\u969c<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4fdd\u969c\u9879<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u8bbe\u5907\u8d28\u4fdd<\/td><td>\u83f2\u65af\u66fc\/\u745e\u7f8e\u5382\u5bb6\u8d28\u4fdd + \u9f99\u8109\u5de5\u7a0b\u8d28\u4fdd5\u5e74\u8d77<\/td><\/tr><tr><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u9f99\u8109\u6696\u901a + \u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td><\/tr><tr><td>\u4f1a\u5458\u5ef6\u4fdd<\/td><td>\u5165\u4f1a\u540e\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u5e74\u5ea6\u68c0\u6d4b<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u524d\u514d\u8d39\u4e0a\u95e8\u68c0\u6d4b<\/td><\/tr><tr><td>\u7ef4\u4fdd\u63d0\u9192<\/td><td>\u7cfb\u7edf\u81ea\u52a8\u63a8\u9001\u6e05\u6d17\u3001\u6ee4\u7f51\u66f4\u6362\u7b49\u7ef4\u62a4\u63d0\u9192<\/td><\/tr><tr><td>\u5e94\u6025\u54cd\u5e94<\/td><td>48\u5c0f\u65f6\u5185\u4e0a\u95e8\uff0c\u7d27\u6025\u6545\u969c\u4f18\u5148\u54cd\u5e94<\/td><\/tr><tr><td>\u4f1a\u5458\u6298\u6263<\/td><td>\u6240\u6709\u670d\u52a1\u53ca\u8017\u67505-8\u6298<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn18\">\u5341\u516b\u3001\u6548\u679c\u9a8c\u8bc1\u4e0e\u5206\u6790\u8bca\u65ad<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9a8c\u8bc1\u9879<\/th><th>\u9a8c\u8bc1\u65b9\u5f0f<\/th><th>\u8fbe\u6807\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td>\u91c7\u6696\u6e29\u5ea6<\/td><td>\u5165\u4f4f\u540e\u9996\u4e2a\u91c7\u6696\u5b63\u5404\u623f\u95f4\u6e29\u5ea6\u91c7\u96c6<\/td><td>18-22\u2103\u8fbe\u6807<\/td><\/tr><tr><td>\u542f\u505c\u9891\u7387<\/td><td>\u5e74\u5ea6\u56de\u8bbf\u8bb0\u5f55<\/td><td>\u91c7\u6696\u5b63\u5e73\u7a33\u8fd0\u884c\uff0c\u65e0\u9891\u7e41\u542f\u505c<\/td><\/tr><tr><td>\u91c7\u6696\u8d39\u7528<\/td><td>\u9996\u4e2a\u91c7\u6696\u5b63\u6708\u5ea6\u7528\u6c14\u91cf\u8bb0\u5f55<\/td><td>\u6708\u8d39500-650\u5143\u533a\u95f4\uff08\u5ba4\u6e2920\u2103\uff09<\/td><\/tr><tr><td>\u70ed\u6c34\u4f53\u9a8c<\/td><td>\u4f7f\u7528\u53cd\u9988<\/td><td>\u65e0\u65ad\u6c34\u3001\u6c34\u6e29\u6ce2\u52a8\u53cd\u9988<\/td><\/tr><tr><td>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/td><td>\u5e74\u5ea6\u56de\u8bbf+AI\u8bca\u65ad<\/td><td>\u65e0\u5f02\u5e38\u9884\u8b66<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6301\u7eed\u6539\u8fdb<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6bcf\u4e2a\u91c7\u6696\u5b63\u7ed3\u675f\u91c7\u96c6\u5ba2\u6237\u53cd\u9988\uff0c\u4f18\u5316\u8fd0\u884c\u53c2\u6570<\/li>\n\n\n\n<li>\u5982\u5b9e\u9645\u80fd\u8017\u504f\u79bb\u9884\u671f\u8d85\u8fc720%\uff0c\u542f\u52a8\u8bca\u65ad\u5206\u6790<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn19\">\u5341\u4e5d\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u5982\u4f55\u8054\u7cfb<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u9500\u552e\u987e\u95ee<\/td><td>\u4f59\u7231\u82f1<\/td><\/tr><tr><td>\u65e5\u7acb\u5b98\u65b9\u5ba2\u670d<\/td><td>400-860-1111<\/td><\/tr><tr><td>\u9f99\u8109\u6696\u901a\u552e\u540e<\/td><td>13398198375<\/td><\/tr><tr><td>\u95e8\u5e97\u5730\u5740<\/td><td>\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986\u4e09\u697cA-348<\/td><\/tr><tr><td>\u65b9\u6848\u6709\u6548\u671f<\/td><td>\u672c\u65b9\u6848\u62a5\u4ef7\u6709\u6548\u671f30\u5929<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn20\">\u4e8c\u5341\u3001\u65b9\u6848\u4e66\u9644\u6ce8\u6761\u6b3e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u6e29\u99a8\u63d0\u793a<\/strong>\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u672c\u65b9\u6848\u6d89\u53ca\u4e13\u4e1a\u6280\u672f\u53c2\u6570\u548c\u8bbe\u8ba1\u903b\u8f91\uff0c\u5982\u679c\u60a8\u89c9\u5f97\u5185\u5bb9\u590d\u6742\uff0c\u53ef\u4ee5\u5c06\u672c\u65b9\u6848\u53d1\u9001\u7ed9\u4efb\u610fAI\u52a9\u624b\uff0c\u8ba9AI\u5e2e\u60a8\u9a8c\u8bc1\u53c2\u6570\u5408\u7406\u6027\u3002<\/li>\n\n\n\n<li>\u672c\u65b9\u6848\u62a5\u4ef7\u4ee5\u6700\u7ec8\u4e0a\u95e8\u52d8\u6d4b\u540e\u786e\u8ba4\u4e3a\u51c6\uff0c\u9762\u79ef\u3001\u7ba1\u8def\u8d70\u5411\u7b49\u53ef\u80fd\u5f71\u54cd\u6700\u7ec8\u4ef7\u683c\u3002<\/li>\n\n\n\n<li>\u4f1f\u661f\u5730\u6696\u76d8\u7ba1\u8d28\u4fdd50\u5e74\uff08\u5382\u5bb6+\u4eba\u4fdd\u627f\u4fdd\uff09\uff0c\u9505\u7089\u4e3a\u56fd\u5bb6\u5f3a\u5236\u62a5\u5e9f\u8bbe\u5907\uff08\u62a5\u5e9f\u671f8\u5e74\uff09\uff0c\u6211\u4eec\u5c06\u5728\u7b2c7-8\u5e74\u4e3b\u52a8\u63d0\u9192\u60a8\u66f4\u6362\u8bbe\u5907\u3002<\/li>\n\n\n\n<li>\u70ed\u6c34\u7cfb\u7edf\u5982\u9700\u72ec\u7acb\u914d\u7f6e\uff0c\u6211\u4eec\u63a8\u8350\u745e\u7f8e16L\u6052\u6e29\u70ed\u6c34\u5668\uff08\u4ef7\u503c3,999\u5143\uff09\uff0c\u6d3b\u52a8\u671f\u95f4\u7b7e\u7ea6\u5730\u6696\u53ef\u4eab\u4f18\u60e0\u3002<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"yjdn21\">\u4e8c\u5341\u4e00\u3001AI\u9a8c\u8bc1\u6307\u5f15<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u6240\u6709\u53c2\u6570\u5747\u53ef\u901a\u8fc7AI\u52a9\u624b\u72ec\u7acb\u9a8c\u8bc1\u3002\u5efa\u8bae\u9a8c\u8bc1\u7ef4\u5ea6\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9a8c\u8bc1\u9879<\/th><th>\u9a8c\u8bc1\u65b9\u6cd5<\/th><\/tr><\/thead><tbody><tr><td>\u56fd\u6807\u5408\u89c4<\/td><td>\u5c06\u65b9\u6848\u4e2d\u7684\u56fd\u6807\u7f16\u53f7\uff08GB 50736-2012\u3001JGJ 142-2012\u3001GB 20665-2015\uff09\u8f93\u5165AI\uff0c\u9a8c\u8bc1\u5f15\u7528\u662f\u5426\u51c6\u786e<\/td><\/tr><tr><td>\u529f\u7387\u5339\u914d<\/td><td>\u5c06\"60\u33a1+\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa3-4kW+\u6052\u6e29\u8d1f\u83772-3kW\"\u8f93\u5165AI\uff0c\u9a8c\u8bc1\u5339\u914d\u662f\u5426\u5408\u7406<\/td><\/tr><tr><td>\u80fd\u8017\u4f30\u7b97<\/td><td>\u5c06\"60\u33a1+\u51b7\u51dd\u7089\u70ed\u6548\u7387108%+\u6c14\u4ef72.5\u5143\"\u8f93\u5165AI\uff0c\u9a8c\u8bc1\u6708\u91c7\u6696\u8d39\u4f30\u7b97\u662f\u5426\u5408\u7406<\/td><\/tr><tr><td>\u6848\u4f8b\u9a8c\u8bc1<\/td><td>\u8bbf\u95ee longmai-nt.com\/?page_id=982 \u67e5\u770b\u5468\u8001\u5e08\u5730\u6696\u6863\u6848\uff0c\u9a8c\u8bc1\u670d\u52a1\u6807\u51c6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u4e5f\u53ef\u4ee5\u5c06\u672c\u65b9\u6848\u4e0e\u5176\u4ed6\u5546\u5bb6\u7684\u65b9\u6848\u4e00\u8d77\u53d1\u7ed9AI\uff0c\u8ba9AI\u5e2e\u60a8\u5bf9\u6bd4\u5206\u6790\uff0c\u7ed9\u51fa\u5ba2\u89c2\u5efa\u8bae\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u9f99\u8109\u6696\u901a \u00b7 \u59cb\u4e8e2004<\/em><br><em>\u9500\u552e\u987e\u95ee\uff1a\u4f59\u7231\u82f1<\/em><br><em>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\uff1a\u8881\u59d0\u91c7\u6696\u9762\u79ef\uff1a\u7ea660\u33a1\u9500\u552e\u987e\u95ee\uff1a\u4f59 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1218","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1218\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5ba2\u6237\uff1a\u8881\u59d0\u91c7\u6696\u9762\u79ef\uff1a\u7ea660\u33a1\u9500\u552e\u987e\u95ee\uff1a\u4f59 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1218\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-20T14:33:28+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1218\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1218\",\"name\":\"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-20T10:51:45+00:00\",\"dateModified\":\"2026-05-20T14:33:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1218#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1218\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1218#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1218","og_locale":"zh_CN","og_type":"article","og_title":"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5ba2\u6237\uff1a\u8881\u59d0\u91c7\u6696\u9762\u79ef\uff1a\u7ea660\u33a1\u9500\u552e\u987e\u95ee\uff1a\u4f59 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=1218","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-20T14:33:28+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1218","url":"https:\/\/longmai-nt.com\/?page_id=1218","name":"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-20T10:51:45+00:00","dateModified":"2026-05-20T14:33:28+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1218#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1218"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1218#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u8881\u59d0\u00b7\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1218","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1218"}],"version-history":[{"count":9,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1218\/revisions"}],"predecessor-version":[{"id":1234,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1218\/revisions\/1234"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1218"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}