{"id":12439,"date":"2026-09-13T00:58:47","date_gmt":"2026-09-12T16:58:47","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=12439"},"modified":"2026-10-19T00:25:22","modified_gmt":"2026-10-18T16:25:22","slug":"%e5%9c%b0%e6%9a%96%e7%b3%bb%e7%bb%9f%e7%99%bd%e7%9a%ae%e4%b9%a6%ef%bc%9a%e7%83%ad%e6%ba%90%e9%80%89%e5%9e%8b%e3%80%81%e7%9b%98%e7%ae%a1%e8%ae%be%e8%ae%a1%e3%80%81%e6%96%bd%e5%b7%a5%e9%aa%8c%e6%94%b6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=12439","title":{"rendered":"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3"},"content":{"rendered":"\n<style>\n.lm-wrap{max-width:900px;margin:0 auto;padding:0 4px;font-size:16px;line-height:1.9;color:#242424;font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;}\n.lm-wrap h1{font-size:27px;line-height:1.5;font-weight:800;color:#1a1a1a;margin:0 0 14px;}\n.lm-wrap h2{font-size:21px;line-height:1.5;font-weight:800;color:#1a1a1a;margin:40px 0 12px;padding-left:12px;border-left:5px solid #c0392b;}\n.lm-wrap h3{font-size:18px;line-height:1.55;font-weight:700;color:#2c3e50;margin:26px 0 10px;}\n.lm-wrap h4{font-size:16.5px;line-height:1.6;font-weight:700;color:#34495e;margin:20px 0 8px;}\n.lm-wrap p{margin:0 0 13px;}\n.lm-wrap ul,.lm-wrap ol{margin:0 0 14px;padding-left:24px;}\n.lm-wrap li{margin-bottom:7px;}\n.lm-meta{background:#fbf7f2;border:1px solid #f0e2d2;border-radius:10px;padding:14px 16px;margin:0 0 22px;font-size:14px;line-height:1.85;color:#5a4a3a;}\n.lm-sum{background:#f7f9fb;border:1px solid #e3ebf2;border-radius:10px;padding:15px 17px;margin:0 0 24px;font-size:15px;line-height:1.85;color:#33475b;}\n.lm-tip{background:#fff8e6;border:1px solid #f5e2b0;border-left:4px solid #e6a817;border-radius:8px;padding:13px 16px;margin:16px 0;font-size:15px;line-height:1.8;}\n.lm-warn{background:#fdf2f0;border:1px solid #f5d3cc;border-left:4px solid #c0392b;border-radius:8px;padding:13px 16px;margin:16px 0;font-size:15px;line-height:1.8;}\n.lm-key{background:#eef7ef;border:1px solid #cfe6d2;border-left:4px solid #27ae60;border-radius:8px;padding:13px 16px;margin:16px 0;font-size:15px;line-height:1.8;}\n.lm-tb{width:100%;border-collapse:collapse;margin:16px 0;font-size:14.5px;line-height:1.7;}\n.lm-tb th{background:#c0392b;color:#fff;padding:9px 10px;text-align:left;font-weight:700;border:1px solid #b0332a;}\n.lm-tb td{padding:9px 10px;border:1px solid #e6e6e6;vertical-align:top;}\n.lm-tb tr:nth-child(even) td{background:#fafafa;}\n.lm-tb-wrap{overflow-x:auto;margin:16px 0;}\n.lm-link{color:#c0392b;text-decoration:underline;text-underline-offset:2px;}\n.lm-fig{margin:20px 0;}\n.lm-fig img{width:100%;height:auto;border-radius:10px;display:block;}.lm-fig img.lmtall{max-height:520px;width:auto;margin:0 auto;}\n.lm-fig figcaption{font-size:13.5px;color:#777;margin-top:7px;line-height:1.6;text-align:center;}\n.lm-case{background:#fafafa;border:1px solid #e8e8e8;border-radius:11px;padding:17px 19px;margin:18px 0;}\n.lm-case h4{margin-top:0;color:#c0392b;}\n.lm-faq{background:#fff;border:1px solid #ececec;border-radius:9px;padding:13px 16px;margin:9px 0;}\n.lm-faq .q{font-weight:700;color:#c0392b;font-size:16.5px;margin:0 0 6px;line-height:1.6;}\n.lm-faq .a{font-size:15px;color:#333;margin:0;line-height:1.85;}\n.lm-card{border:1px solid #ececec;border-radius:9px;padding:11px 14px;margin:8px 0;display:block;background:#fff;color:#242424;text-decoration:none;font-size:15px;}\n.lm-card:hover{background:#fff6f2;border-color:#e8c4b8;}\n.lm-btn{display:inline-block;padding:11px 20px;border-radius:8px;text-decoration:none;font-size:15.5px;font-weight:700;margin:6px 6px 6px 0;}\n.lm-btn-r{background:#c0392b;color:#fff;}\n.lm-btn-d{background:#2c3e50;color:#fff;}\n.lm-btn-o{background:#fff;color:#c0392b;border:1.5px solid #c0392b;}\n.lm-foot{margin-top:34px;padding:16px 18px;background:#f7f7f7;border-radius:10px;font-size:13.5px;color:#777;line-height:1.8;}\n.lm-store{display:flex;flex-wrap:wrap;gap:14px;margin:14px 0;}\n.lm-store>div{flex:1 1 260px;background:#fafafa;border:1px solid #ececec;border-radius:10px;padding:14px 16px;font-size:14.6px;line-height:1.9;}\n@media(max-width:640px){.lm-wrap{font-size:15.5px;}.lm-wrap h1{font-size:22px;}.lm-wrap h2{font-size:19px;}.lm-wrap h3{font-size:17px;}.lm-tb{font-size:13.5px;}.lm-store>div{flex:1 1 100%;}}\n<\/style>\n\n<div class=\"lm-wrap\" data-page-node-id=\"DX36aGEydD69WkidU5HbSe\">\n\n<div class=\"lm-meta\" data-page-node-id=\"pOsW2FU2ULR646NOTEgQpE\">\n<strong data-page-node-id=\"sDYFwm89ECpNEq2bxvaaKo\">\u7248\u672c<\/strong>\uff1aV1.3\u3000\uff5c\u3000<strong data-page-node-id=\"4q3ZbH7gmbsYtlDUJwIpK8\">\u66f4\u65b0\u65e5\u671f<\/strong>\uff1a2026-09-13\u3000\uff5c\u3000<strong data-page-node-id=\"x0EXXH5w1Qt1vgP18ayW2D\">\u57ce\u5e02<\/strong>\uff1a\u6210\u90fd<br data-page-node-id=\"IWoqF5pge47jwChAKyJjuS\">\n<strong data-page-node-id=\"45s9gYlFClLeQbdIXbfAIt\">\u9002\u7528\u5bf9\u8c61<\/strong>\uff1a\u6210\u90fd\u88c5\u4fee\u4e1a\u4e3b\u3001\u6696\u901a\u8bbe\u8ba1\u5e08\u3001\u88c5\u4fee\u9879\u76ee\u7ecf\u7406<br data-page-node-id=\"ROd7SllwErIAplUusb6MXc\">\n<strong data-page-node-id=\"nh5f1Z8N6rT6axDMVEKxY0\">\u6570\u636e\u57fa\u51c6<\/strong>\uff1a\u9f99\u8109\u6696\u901a\u300a\u5730\u6696\u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7\u300b\uff08<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" data-page-node-id=\"yR1cDwqBvCxI5voueN4h9V\">\u5730\u6696\u77e5\u8bc6\u5e95\u5ea7<\/a>\uff09+ \u56fd\u5bb6\u6807\u51c6 GB 50736-2012 \/ JGJ 142-2012 \/ GB 50242-2002 + \u5b98\u7f51<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10977\" data-page-node-id=\"IHaGum4CvkHaQMDF25M4K5\">\u6210\u90fd\u5730\u6696\u4ef7\u683c\u53c2\u8003<\/a>\u771f\u5b9e\u5957\u9910\u5355\u4ef7 + <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\" data-page-node-id=\"mgJBGqMvmmdWCIZqpyDKt1\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/a>\u5b9e\u6d4b\u6570\u636e\u3002<br data-page-node-id=\"DLFmteEnqeNP1tFsy04VcY\">\n<strong data-page-node-id=\"2m9wDbvOSK0X9L7uzAbOa3\">\u672c\u5730\u9002\u7528\u8bf4\u660e<\/strong>\uff1a\u5168\u6587\u70ed\u8d1f\u8377\u53d6\u503c\u3001\u6237\u578b\u53c2\u8003\u3001\u6210\u4ea4\u4ef7\u683c\u4e0e\u8fd0\u884c\u8d39\u7528\u5747\u57fa\u4e8e\u6210\u90fd\u4f4f\u5b85\u6c14\u5019\u6761\u4ef6\uff08\u51ac\u5b63\u5ba4\u5916\u8ba1\u7b97\u6e29\u5ea6\u7ea6 2\u20134\u2103\u3001\u6e7f\u5ea6\u504f\u9ad8\u3001\u5c11\u6709\u96c6\u4e2d\u4f9b\u6696\uff09\u4e0e\u6210\u90fd\u672c\u5730\u6237\u578b\u7ed3\u6784\u6d4b\u7b97\uff0c\u5916\u5730\u8bfb\u8005\u539f\u7406\u53ef\u53c2\u7167\u3001\u6570\u503c\u9700\u6309\u5f53\u5730\u6c14\u5019\u91cd\u65b0\u6838\u7b97\u3002\n<\/div>\n\n<div class=\"lm-sum\" data-page-node-id=\"itPUF9pHYFyofOuhEcnJjf\">\n<strong data-page-node-id=\"Yw3ChxVetvablBFEFL9JAn\">\u4e00\u9875\u8bfb\u5b8c\uff08\u7ed9\u8d76\u65f6\u95f4\u7684\u4eba\uff09<\/strong><br data-page-node-id=\"PRf7vDMyL5lkC5C27Pm7kF\">\n\u2460 \u5730\u6696\u662f\"\u7cfb\u7edf\"\u4e0d\u662f\"\u8bbe\u5907\"\u2014\u2014<strong data-page-node-id=\"zcf2uYThOSZAinyn6huPss\">\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236<\/strong>\u56db\u8981\u7d20\u4efb\u4e00\u73af\u6389\u94fe\u5b50\uff0c\u6574\u5957\u90fd\u4e0d\u70ed\u3001\u90fd\u8d39\u6c14\uff1b<br data-page-node-id=\"b7v1by7cQJzSNZVI7154qR\">\n\u2461 20 \u5e74\u7b97\u603b\u8d26\uff1a\u666e\u901a\u7089\u7ea6 9.50 \u4e07\u3001\u51b7\u51dd\u7089\u7ea6 8.71 \u4e07\u3001\u7a7a\u6c14\u80fd\u7ea6 6.00 \u4e07\u2014\u2014<strong data-page-node-id=\"EMM40pyVvedlGhZ98Lht35\">\u521d\u88c5\u4fbf\u5b9c\u7684\u5f80\u5f80\u603b\u8d26\u6700\u8d35<\/strong>\uff1b<br data-page-node-id=\"pAIwrEEZ27z3iY5lyedMpa\">\n\u2462 \u6210\u90fd\u5730\u6696\u53c2\u8003\u5355\u4ef7\uff1a\u6e05\u6c34\u623f\u603b\u63a7 <strong data-page-node-id=\"dmMDu4qtcF512B9dsQ0mHG\">99 \u5143\/\u33a1<\/strong>\u3001\u7cbe\u88c5\u6539\u9020\u5206\u63a7 <strong data-page-node-id=\"6UG8lkDGW1uN6Zs0PgddHd\">119 \u5143\/\u33a1<\/strong>\u3001\u8282\u80fd\u5305 <strong data-page-node-id=\"jUsdc6bhH2JmO1ofMllRSi\">169 \u5143\/\u33a1<\/strong>\uff08\u6309\u5b9e\u9645\u94fa\u8bbe\u9762\u79ef\u7ed3\u7b97\uff0c\u4e0d\u542b\u9505\u7089\u4e3b\u673a\uff09\uff1b<br data-page-node-id=\"EZXI1mhEEOdMwVNYS0Lwh3\">\n\u2463 \u9a8c\u6536\u7ea2\u7ebf\u53ea\u6709\u4e00\u6761\u5fc5\u987b\u8bb0\u4f4f\uff1a\u6253\u538b <strong data-page-node-id=\"jaMYGluERSEsM2xGoxMFW9\">0.6MPa \u4fdd\u538b 24 \u5c0f\u65f6\uff0c\u538b\u964d \u22640.05MPa<\/strong>\uff1b<br data-page-node-id=\"D7HkAnVDzF1s6Eq2Gq1PGD\">\n\u2464 90% \u7684\"\u5730\u6696\u4e0d\u70ed\/\u8d39\u6c14\"\u4e0d\u662f\u8bbe\u5907\u95ee\u9898\uff0c\u662f<strong data-page-node-id=\"DAQfAOPHjp1JnjKFeIExIy\">\u70ed\u8d1f\u8377\u6ca1\u7b97\u3001\u7ba1\u5f84\u9009\u5c0f\u3001\u6ca1\u6709\u5ba4\u6e29\u8054\u52a8<\/strong>\u8fd9\u4e09\u4e2a\u8bbe\u8ba1\u95ee\u9898\u3002\n<\/div>\n\n<h2 data-page-node-id=\"wOBmgNc6p9hEqc5HBWzIQW\">\u7b2c\u4e00\u7ae0\u3000\u5730\u6696\u4e3a\u4ec0\u4e48\u662f\"\u7cfb\u7edf\"\uff0c\u800c\u4e0d\u662f\u4e00\u53f0\u9505\u7089<\/h2>\n\n<figure class=\"lm-fig\" data-page-node-id=\"YO8hwKC6YAXEIiAuKtcukU\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-1024x576.png\" alt=\"\u6210\u90fd\u4f4f\u5b85\u5ba2\u5385\u5730\u6696\u91c7\u6696\u573a\u666f\u5b9e\u62cd\uff0c\u5730\u9762\u8f90\u5c04\u4f9b\u6696\u5168\u5c4b\u5747\u5300\u6563\u70ed\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-300x169.png 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-768x432.png 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-1024x576.png 1024w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"1024\" height=\"576\">\n<figcaption data-page-node-id=\"5k4auJWZANIeJZLrd9OpI3\">\u5730\u6696\u7684\u8212\u9002\u5ea6\u6765\u81ea\"\u6574\u9762\u5730\u9762\u4f4e\u6e29\u8f90\u5c04\"\uff0c\u800c\u4e0d\u662f\u67d0\u4e2a\u623f\u95f4\u7684\u8bbe\u5907\u529f\u7387<\/figcaption>\n<\/figure>\n\n<p data-page-node-id=\"kM6mznJFXtObQi5jBeWH1R\">\u591a\u6570\u4eba\u7406\u89e3\u7684\u5730\u6696\u662f\"\u4e70\u4e00\u53f0\u58c1\u6302\u7089 + \u5730\u4e0a\u94fa\u4e00\u5708\u7ba1\u5b50\"\u3002\u8fd9\u4e2a\u7406\u89e3\u76f4\u63a5\u5bfc\u81f4\u4e86\u540e\u9762\u6240\u6709\u7684\u5751\uff1a\u9505\u7089\u6309\u6700\u5927\u529f\u7387\u4e70\u3001\u7ba1\u5b50\u6309\u7ecf\u9a8c\u94fa\u3001\u63a7\u5236\u9760\u624b\u6478\u9600\u95e8\u2014\u2014\u6700\u540e\u7ed3\u679c\u662f\"\u88c5\u4e86\u5730\u6696\u4f46\u4e0d\u70ed\u3001\u70ed\u4e86\u4f46\u8d39\u6c14\u3001\u8d39\u6c14\u4e86\u8fd8\u4e0d\u6562\u5f00\"\u3002<\/p>\n\n<p data-page-node-id=\"8nDaWwTPr5pOmHtHXfiK6x\">\u5730\u6696\u771f\u6b63\u7684\u7ed3\u6784\u662f<strong data-page-node-id=\"LI1yygSDc4W4uYppmMhENB\">\u56db\u8981\u7d20\u4e32\u8054\u7684\u4e00\u6761\u94fe\u8def<\/strong>\uff1a<\/p>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"Q3qJaGUquIXvxbifyEnFEw\"><table class=\"lm-tb\" data-page-node-id=\"NkTfGMsbDZk6WlqCpmthxE\">\n<tbody><tr data-page-node-id=\"IUlPQdAc4sHMGCifUHVIYK\"><th style=\"width:16%\" data-page-node-id=\"vQWSGa8amO8VFrZ7pLc4AC\">\u8981\u7d20<\/th><th style=\"width:26%\" data-page-node-id=\"ldKRkU24Nd72iEyNHToCvI\">\u5b83\u8d1f\u8d23\u4ec0\u4e48<\/th><th data-page-node-id=\"C0IjSYwqGSV2PwpHCcUUpK\">\u51fa\u95ee\u9898\u7684\u5178\u578b\u8868\u73b0<\/th><\/tr>\n<tr data-page-node-id=\"cWXoSBSqLwbv0c89hwvCnS\"><td data-page-node-id=\"pRj8rFA6IJRFbJ64Stfrkn\"><strong data-page-node-id=\"oBp1nnYhIHqMlmFL5NQMr1\">\u70ed\u6e90<\/strong><\/td><td data-page-node-id=\"w6zr44EZXRI7es5jlvgWfJ\">\u628a\u71c3\u6c14\/\u7535\/\u7a7a\u6c14\u70ed\u53d8\u6210\u70ed\u6c34<\/td><td data-page-node-id=\"YcfoeEvNq52YM3uB4DCnHH\">\u9891\u7e41\u542f\u505c\u3001\u6c34\u6e29\u5ffd\u9ad8\u5ffd\u4f4e\u3001\u71c3\u6c14\u8d39\u79bb\u8c31<\/td><\/tr>\n<tr data-page-node-id=\"U54o42XamEtb77uKqPO9mZ\"><td data-page-node-id=\"WdY7SxR6trjIRT1yYC6c1u\"><strong data-page-node-id=\"2agkE1gD7q14sENs0dzNvL\">\u8f93\u914d<\/strong><\/td><td data-page-node-id=\"BKIJY7sVwIjSTHsMUD6rZk\">\u628a\u70ed\u6c34\u6309\u91cf\u9001\u5230\u6bcf\u4e2a\u56de\u8def<\/td><td data-page-node-id=\"Jirg2Bqis3wofDBCpadgN4\">\u8fdc\u7aef\u623f\u95f4\u4e0d\u70ed\u3001\u5206\u6c34\u5668\u524d\u70ed\u540e\u51c9\u3001\u6c34\u6d41\u566a\u58f0<\/td><\/tr>\n<tr data-page-node-id=\"7RCDMjepXcixj8YgOxOayj\"><td data-page-node-id=\"Yybsn8vKEmMzrAUbEuzS0n\"><strong data-page-node-id=\"Qp5siP8CIv5RjBrYNWpDvZ\">\u672b\u7aef<\/strong><\/td><td data-page-node-id=\"HiSNmm1cqollU5MhfiW9MT\">\u76d8\u7ba1 + \u56de\u586b\u5c42\u628a\u70ed\u6563\u8fdb\u623f\u95f4<\/td><td data-page-node-id=\"GJklDIiGcfjyZIivWQ0O2U\">\u5730\u9762\u5c40\u90e8\u8fc7\u70ed\u3001\u5347\u6e29\u6162\u3001\u697c\u677f\u5411\u4e0b\u4f20\u70ed\u767d\u70e7<\/td><\/tr>\n<tr data-page-node-id=\"92r0GMMpLDKT44LoFf6F3y\"><td data-page-node-id=\"98pk1bc5CGw22z4xJ9aaJb\"><strong data-page-node-id=\"2a4RQMu5LKc9JVQuQ2x93V\">\u63a7\u5236<\/strong><\/td><td data-page-node-id=\"r2J35qPc0GQ2QDoC1cu91Y\">\u51b3\u5b9a\"\u4ec0\u4e48\u65f6\u5019\u70e7\u3001\u70e7\u5230\u51e0\u5ea6\"<\/td><td data-page-node-id=\"NjnFx6X5ozOFCJq3CCuOIj\">\u5ba4\u6e29\u5230\u4e86\u8fd8\u5728\u70e7\u3001\u767d\u5929\u6ca1\u4eba\u4e5f\u5168\u5c4b\u5f00\u7740<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-key\" data-page-node-id=\"uRlXNvnI8qc8uqSfu7mesK\">\n<strong data-page-node-id=\"JZuDjJYt9ULqcxdpQmHh5g\">\u56db\u8981\u7d20\u5339\u914d\u7684\u9ec4\u91d1\u6cd5\u5219<\/strong>\uff1a\u8fd9\u56db\u4e2a\u8981\u7d20\u5fc5\u987b<strong data-page-node-id=\"DsSdYKeWnpuJhyfbZb2nWM\">\u6309\u540c\u4e00\u4e2a\u8bbe\u8ba1\u70ed\u8d1f\u8377\u53cd\u63a8<\/strong>\u51fa\u6765\uff0c\u800c\u4e0d\u662f\u5404\u81ea\"\u4e70\u597d\u7684\"\u3001\"\u6309\u7ecf\u9a8c\u505a\"\u3002\n\u540e\u9762\u7b2c\u4e8c\u5230\u7b2c\u4e94\u7ae0\uff0c\u6211\u4eec\u6309\"\u70ed\u6e90 \u2192 \u8f93\u914d \u2192 \u672b\u7aef\u63a7\u5236 \u2192 \u8bbe\u8ba1\u89c4\u8303\"\u7684\u987a\u5e8f\u9010\u5c42\u62c6\u5f00\u3002\n<\/div>\n\n<h2 data-page-node-id=\"ZI4HCCHXGQRVKHaEpV3N7w\">\u7b2c\u4e8c\u7ae0\u3000\u70ed\u6e90\uff1a\u7cfb\u7edf\u7684\u5fc3\u810f\uff0c\u4e5f\u662f 20 \u5e74\u8d26\u5355\u7684\u8d77\u70b9<\/h2>\n\n<h3 data-page-node-id=\"EbTlIqpTHSQcO3osPoyT7R\">2.1\u3000\u4e09\u5927\u70ed\u6e90\u9635\u8425\u5168\u666f\u5bf9\u6bd4<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"mPBGhKZVACxCKyUGKmnnrw\"><table class=\"lm-tb\" data-page-node-id=\"izNCohwdSdKGdcvq4czRql\">\n<tbody><tr data-page-node-id=\"ARMlmBn5R9LXXDL8Noe4jA\"><th style=\"width:15%\" data-page-node-id=\"VZTe0IHVFFdFP6laybmZYd\">\u7ef4\u5ea6<\/th><th style=\"width:28%\" data-page-node-id=\"8FgFCuH83q320NJY9rDI0L\">\u71c3\u6c14\u58c1\u6302\u7089<\/th><th style=\"width:28%\" data-page-node-id=\"tYOqPN2Zq2tV3iJXaPW73i\">\u7a7a\u6c14\u80fd\u70ed\u6cf5<\/th><th data-page-node-id=\"JjdT6P0IhTyjACjHTklAEc\">\u7535\u5730\u6696<\/th><\/tr>\n<tr data-page-node-id=\"qy4y5AcXY38JTXcrrPeXFa\"><td data-page-node-id=\"ariudJH92kzECuUlNKwhAt\"><strong data-page-node-id=\"ZvVEieZOLYHhiuTAWEaUBR\">\u6838\u5fc3\u539f\u7406<\/strong><\/td><td data-page-node-id=\"JFARewQ2mCsW2FMFOOnNZ6\">\u71c3\u70e7\u5929\u7136\u6c14\u52a0\u70ed\u5faa\u73af\u6c34<\/td><td data-page-node-id=\"ej8LWqd7Y0WSmZ1w6ADWty\">\u5438\u6536\u7a7a\u6c14\u70ed\u80fd\uff0c\u538b\u7f29\u673a\u642c\u8fd0\u81f3\u6c34\u4e2d<\/td><td data-page-node-id=\"X6dnrn5wrRo8ufCRUH97cP\">\u7535\u80fd\u76f4\u63a5\u8f6c\u5316\u4e3a\u70ed\u80fd<\/td><\/tr>\n<tr data-page-node-id=\"ibLthpbsYcMPrOXQn0qcxd\"><td data-page-node-id=\"fCs38t7KJdSV5HR7kX6hrM\"><strong data-page-node-id=\"EwvTfg8jotbhiziUh2dDCc\">\u80fd\u6548\u6bd4<\/strong><\/td><td data-page-node-id=\"HoewR74tSs8bCsjw5o3MRI\">\u70ed\u6548\u7387 85%\u2013105%\uff08\u51b7\u51dd\u7089\uff09<\/td><td data-page-node-id=\"BoGSuJ4EIQZD0BI8zpZqOp\">COP 3.0\u20134.0\uff08\u5e38\u6e29\uff09<\/td><td data-page-node-id=\"5beCWytIjGizAlvXNGXqpx\">\u7ea6 0.95\u20130.98\uff081 \u5ea6\u7535 = 1 \u5ea6\u70ed\uff09<\/td><\/tr>\n<tr data-page-node-id=\"su4Ee32I6TEGnYwXSNOx5W\"><td data-page-node-id=\"rDj8cEbix5IWtTXDdKSBNb\"><strong data-page-node-id=\"jUF1Cz3pXwGHFC275ZbplK\">100\u33a1 \u6708\u8fd0\u884c\u8d39<\/strong><\/td><td data-page-node-id=\"9SKqFN8nduHHyoNaeaVyNT\">780\u20131300 \u5143<\/td><td data-page-node-id=\"9DqCEUbIFgqf4d45bDA5Yj\">450\u2013650 \u5143<\/td><td data-page-node-id=\"SsGobyNS5rYys0uUi05F4Y\">1200\u20131800 \u5143<\/td><\/tr>\n<tr data-page-node-id=\"N5HVvPywK6luZCFbbbXrCv\"><td data-page-node-id=\"vqVhWvy6WIomXOnfYbQBdZ\"><strong data-page-node-id=\"kvxWvBHeytsu4n18FOcCwM\">\u521d\u88c5\u8d39\u7528<\/strong><\/td><td data-page-node-id=\"xtGbiyq4e917pHuQR9QNfd\">1.5\u20132.5 \u4e07\u5143<\/td><td data-page-node-id=\"sSg9Mhzh3bve3BK8PyBMSi\">2.5\u20134.0 \u4e07\u5143<\/td><td data-page-node-id=\"BsJwc1sy2xTsQkNzzwjxyc\">0.8\u20131.5 \u4e07\u5143<\/td><\/tr>\n<tr data-page-node-id=\"5pOEc2XnVGa4CCKH1DIlBB\"><td data-page-node-id=\"vEy5n1tlU0aXTAQ7IYO7pK\"><strong data-page-node-id=\"MiHDXTXiygl2LQRMXXOABS\">\u5347\u6e29\u901f\u5ea6<\/strong><\/td><td data-page-node-id=\"DF9N2rCZ0SZm2oAQPZbyO2\">\u6162\uff082\u20134 \u5c0f\u65f6\uff0c\u50a8\u70ed\u5f0f\uff09<\/td><td data-page-node-id=\"u3IclYiNCHEqu8mZgeVETK\">\u6162\uff08\u540c\u6c34\u5730\u6696\uff09<\/td><td data-page-node-id=\"7M6qMXZCsk91GhCaFKXn7s\">\u5feb\uff0830 \u5206\u949f\u20131 \u5c0f\u65f6\uff09<\/td><\/tr>\n<tr data-page-node-id=\"X19bW92KnqzrcT7sB1iIBd\"><td data-page-node-id=\"ivnsPjn5b7tTOmBm2kl6MJ\"><strong data-page-node-id=\"8gb4TfFerAQHcxasbCKLNW\">\u9002\u7528\u9762\u79ef<\/strong><\/td><td data-page-node-id=\"iwUoMGtFEZFnmcNCileeoA\">\u226580\u33a1\uff08\u5927\u9762\u79ef\u66f4\u7ecf\u6d4e\uff09<\/td><td data-page-node-id=\"FYJvZLtL2JzVrj08TEMA1i\">\u2265100\u33a1\uff08\u5206\u644a\u8bbe\u5907\u6210\u672c\uff09<\/td><td data-page-node-id=\"HbMzstBtBgqAcaSRTs3igN\">5\u201350\u33a1\uff08\u5c0f\u9762\u79ef\u7075\u6d3b\uff09<\/td><\/tr>\n<tr data-page-node-id=\"2Qhq4bmoWAyVaNppSDF4uY\"><td data-page-node-id=\"lyL3h4fypJPHypd4w5AXI2\"><strong data-page-node-id=\"rwgyQCeSTl285XJK5GyTvn\">\u4f4e\u6e29\u6027\u80fd<\/strong><\/td><td data-page-node-id=\"EzjDVnjE4xDz057XSLGvbx\">\u4e0d\u53d7\u5ba4\u5916\u6e29\u5ea6\u5f71\u54cd<\/td><td data-page-node-id=\"AyjR6F2HAAVvBOZpSZXOXl\">-5\u2103 \u4ee5\u4e0b COP \u4e0b\u964d\uff1b-20\u2103 \u9700\u8865\u6c14\u589e\u7113\u673a\u578b<\/td><td data-page-node-id=\"UTxGMtIDanU6lAtKgymeeo\">\u4e0d\u53d7\u5ba4\u5916\u6e29\u5ea6\u5f71\u54cd<\/td><\/tr>\n<tr data-page-node-id=\"1z4UmMJte34q6lsimNS2sE\"><td data-page-node-id=\"VQB0bPaOPsUrgezgmXjiRi\"><strong data-page-node-id=\"wxw5VSakzFPgXOm6hzALvP\">\u78b3\u6392\u653e<\/strong><\/td><td data-page-node-id=\"DHJe9bJoLSNMIS2LuH47UC\">\u8f83\u9ad8\uff08\u6bcf\u91c7\u6696\u5b63 2500\u20133000kg CO\u2082\uff09<\/td><td data-page-node-id=\"VvVFFCoHKSVDEoRWa0LwcA\">\u7ea6\u4e3a\u71c3\u6c14\u7684 1\/3<\/td><td data-page-node-id=\"nQpKNW7phRowb3ir38Sv0y\">\u53d6\u51b3\u4e8e\u53d1\u7535\u7ed3\u6784\uff08\u706b\u7535\u533a\u6bd4\u71c3\u6c14\u9ad8 2 \u500d\u4ee5\u4e0a\uff09<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<h3 data-page-node-id=\"S9SqIEpIGTLSDlmIm5vHOV\">2.2\u300020 \u5e74\u603b\u6295\u5165\uff1a\u521d\u88c5\u4fbf\u5b9c\u7684\uff0c\u5f80\u5f80\u603b\u8d26\u6700\u8d35<\/h3>\n\n<p data-page-node-id=\"QsFqMQZZOR5FksI5wSn3SC\">\u8fd9\u662f\u5168\u7bc7\u6700\u8be5\u770b\u7684\u4e00\u5f20\u8868\u3002\u4ee5 100\u33a1 \u5730\u6696\u3001\u6bcf\u5e74 120 \u5929\u91c7\u6696\u5b63\u4e3a\u57fa\u51c6\uff1a<\/p>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"f1lPP9mwhVKNHLaQZAWjDW\"><table class=\"lm-tb\" data-page-node-id=\"FslTDE8MAo3oCtwzp7O5Bb\">\n<tbody><tr data-page-node-id=\"L08tcnjlObDG5XueYDb4CO\"><th style=\"width:22%\" data-page-node-id=\"Gr5nAiHfQRJbsc7Hgg0oI9\">\u70ed\u6e90\u7c7b\u578b<\/th><th style=\"width:16%\" data-page-node-id=\"L8uPqQs9fF23drEJtnS5Uz\">\u5b63\u8fd0\u884c\u8d39<\/th><th style=\"width:18%\" data-page-node-id=\"5xoX0mEQXOahfv8Do21AHA\">\u70ed\u6e90\u521d\u88c5\u6210\u672c<\/th><th style=\"width:18%\" data-page-node-id=\"nrJ8SB0xyWriBu1Hs6WuiU\">20 \u5e74\u603b\u6295\u5165<\/th><th data-page-node-id=\"3FUsgm7PJMB8dByqhSCxdu\">\u5bff\u547d\u4f30\u7b97<\/th><\/tr>\n<tr data-page-node-id=\"gF4tNieua2Ju6H61FdP7TF\"><td data-page-node-id=\"2LH7TBh3gCPHsIZl4mUeZx\">\u666e\u901a\u7089\uff0824kW\uff09<\/td><td data-page-node-id=\"s3kQIFMFXdxII0Z74iDUbV\">3,780 \u5143<\/td><td data-page-node-id=\"1H5GenzbJkwe6EqKI0s6fN\">\u7ea6 9,700 \u5143<\/td><td data-page-node-id=\"vXFyH1T8icmA4u7Qtg4AZz\"><strong data-page-node-id=\"zPiPuAg4ZB0azwrW5yp1TD\">\u7ea6 95,000 \u5143<\/strong>\uff08+35,000\uff09<\/td><td data-page-node-id=\"ZmbfwW89KZNEvJgHpWeZwW\">8\u201310 \u5e74\uff08\u9700\u66f4\u6362 1 \u6b21\uff09<\/td><\/tr>\n<tr data-page-node-id=\"CT73yTm8ADJ8RHbODxC5N6\"><td data-page-node-id=\"YEoKgG0CTCLFlF3TU89Suu\">\u51b7\u51dd\u7089\uff0825kW\uff09<\/td><td data-page-node-id=\"MuygBMn72iZUgsELAdG5eB\">3,156 \u5143<\/td><td data-page-node-id=\"pAy6S4KUmpr6YiGXaBFRpn\">\u7ea6 12,000 \u5143<\/td><td data-page-node-id=\"e20FFaxlFA2usM9k1LvUEH\"><strong data-page-node-id=\"bkLC11cTAblHBKrdpZnNJ6\">\u7ea6 87,100 \u5143<\/strong>\uff08+27,100\uff09<\/td><td data-page-node-id=\"JlxeadRTTFFjfqAHhV4qRc\">10\u201315 \u5e74\uff08\u9700\u66f4\u6362 1 \u6b21\uff09<\/td><\/tr>\n<tr data-page-node-id=\"0kM5wtRqE4hcCWK9BeMC7X\"><td data-page-node-id=\"NugRgRysZATcjvAIooaSng\">\u7a7a\u6c14\u80fd\u6c34\u6a21\u5757<\/td><td data-page-node-id=\"ecBGf2yCRVHgnmy9KINQfI\">2,400 \u5143<\/td><td data-page-node-id=\"bos8E1KfvO0A6EKPj3dyH4\">\u7ea6 12,000 \u5143<\/td><td data-page-node-id=\"0z8ZMK6n1JlHjZyTCAI4iL\"><strong data-page-node-id=\"It9zLYMcvV5cfPDGUWFNww\">\u7ea6 60,000 \u5143<\/strong>\uff08\u57fa\u51c6\uff09<\/td><td data-page-node-id=\"bYB2jkfjJEQfNAAeAedMVA\">20 \u5e74\u4ee5\u4e0a\uff08\u65e0\u9700\u66f4\u6362\u4e3b\u673a\uff09<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-tip\" data-page-node-id=\"lmnote20y\">\n<strong>\u53e3\u5f84\u8bf4\u660e\uff08\u53ef\u9a8c\u7b97\uff09<\/strong>\uff1a20 \u5e74\u603b\u6295\u5165 \uff1d \u70ed\u6e90\u521d\u88c5\u6210\u672c \uff0b \u5b63\u8fd0\u884c\u8d39 \u00d7 20 \uff0b \u5bff\u547d\u5185\u66f4\u6362\u6210\u672c\uff08\u66f4\u6362\u4e00\u6b21\u6309\u521d\u88c5\u7b49\u989d\u8ba1\uff1b\u7a7a\u6c14\u80fd\u4e3b\u673a 20 \u5e74\u5185\u65e0\u9700\u66f4\u6362\uff09\u3002<br>\n\u666e\u901a\u7089\uff1a9,700 \uff0b 3,780\u00d720\uff0875,600\uff09\uff0b 9,700 \uff1d <strong>\u7ea6 95,000 \u5143<\/strong>\uff1b<br>\n\u51b7\u51dd\u7089\uff1a12,000 \uff0b 3,156\u00d720\uff0863,120\uff09\uff0b 12,000 \uff1d <strong>\u7ea6 87,100 \u5143<\/strong>\uff1b<br>\n\u7a7a\u6c14\u80fd\uff1a12,000 \uff0b 2,400\u00d720\uff0848,000\uff09\uff0b 0 \uff1d <strong>\u7ea6 60,000 \u5143<\/strong>\u3002<br>\n\u672c\u8868\u53ea\u5bf9\u6bd4<strong>\u70ed\u6e90\u7ef4\u5ea6<\/strong>\u7684\u5dee\u5f02\uff0c\u4e0d\u542b\u5730\u6696\u672b\u7aef\u3001\u5206\u96c6\u6c34\u5668\u4e0e\u63a7\u5236\u7cfb\u7edf\u2014\u2014\u4e09\u79cd\u70ed\u6e90\u5171\u7528\u540c\u4e00\u5957\u672b\u7aef\uff0c\u5bf9\u6bd4\u65f6\u76f8\u4e92\u62b5\u6d88\u3002\u6574\u5957\u7cfb\u7edf\u521d\u88c5\u8d39\u7528\u89c1 2.1 \u8868\u3002\n<\/div>\n\n<div class=\"lm-key\" data-page-node-id=\"BAv9ZO6K5mEopxRmGTeyXo\">\n<strong data-page-node-id=\"DxHHjflS3O6mVQbS1sQngv\">\u4e09\u6761\u7ed3\u8bba<\/strong><br data-page-node-id=\"5yPzH1NqMBYqKRnlkbdpBC\">\n\u2460 <strong data-page-node-id=\"eF90khTusUmOecnTDWdX9T\">\u7a7a\u6c14\u80fd\u662f\u957f\u671f\u6700\u4f18<\/strong>\uff1a\u521d\u88c5\u4e0e\u51b7\u51dd\u7089\u76f8\u5f53\uff0c\u4f46 20 \u5e74\u603b\u6295\u5165\u6700\u4f4e\uff086.0 \u4e07\uff09\uff0c\u9002\u5408\u957f\u671f\u81ea\u4f4f\uff1b<br data-page-node-id=\"SuA0KXtQgIKpXkPs7s0d27\">\n\u2461 <strong data-page-node-id=\"s3LOFp4H4YbQ1OM29a8Abu\">\u51b7\u51dd\u7089\u4f18\u4e8e\u666e\u901a\u7089<\/strong>\uff1a20 \u5e74\u7ef4\u5ea6\u7701\u7ea6 0.8 \u4e07\u5143\uff08\u7ea6 7,900 \u5143\uff09\uff0c\u9884\u7b97\u5141\u8bb8\u4f18\u5148\u51b7\u51dd\u7089\uff08\u771f\u5b9e\u6848\u4f8b\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=8190\">\u9526\u6c5f\u9038\u5bb6 61\u33a1 \u83f2\u65af\u66fc B1JG \u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf<\/a>\uff09\uff1b<br data-page-node-id=\"tVkfOl8BqgaEu66zN7nvbG\">\n\u2462 <strong data-page-node-id=\"K4lZljGcZm3eC3K1fnxncw\">\"\u4fbf\u5b9c\"\u7684\u7089\u5b50\u53ef\u80fd\u66f4\u8d35<\/strong>\uff1a\u666e\u901a\u7089\u521d\u88c5\u6700\u7701\uff0c\u957f\u671f\u8fd0\u884c\u6210\u672c\u6700\u9ad8\u2014\u2014\u8981\u770b 20 \u5e74\u603b\u8d26\uff0c\u4e0d\u8981\u53ea\u770b\u4e00\u6b21\u4ef7\u683c\u3002\n<\/div>\n\n<h3 data-page-node-id=\"pDUXMBB7oRpVlwDCM5chQp\">2.3\u3000\u70ed\u6e90\u9009\u578b\u4e09\u539f\u5219\u4e0e\"\u62a5\u8b66\u6761\u4ef6\"<\/h3>\n\n<p data-page-node-id=\"9vPrJAtFGAPJgBthc2wqhw\">\u9f99\u8109\u5185\u90e8\u7528\u7684\u9009\u578b\u6821\u9a8c\u6e05\u5355\uff0c\u6ee1\u8db3\u4ee5\u4e0b\u4efb\u610f\u4e00\u6761\uff0c\u8bf4\u660e\u70ed\u6e90\u9009\u578b\u6709\u91cd\u5927\u98ce\u9669\uff0c<strong data-page-node-id=\"aqCl7QtB0rfu6CSRwhzcTr\">\u5fc5\u987b\u91cd\u65b0\u8bbe\u8ba1<\/strong>\uff1a<\/p>\n\n<div class=\"lm-warn\" data-page-node-id=\"ubF26c7CTCoWcX3pCch0wB\">\n\u2460 \u9505\u7089\u9009\u578b\u529f\u7387 &gt; \u8bbe\u8ba1\u70ed\u8d1f\u8377 \u00d7 1.3\uff08\u8d85\u51fa 30% \u4ee5\u4e0a\uff09\uff1b<br data-page-node-id=\"Gnn9y7nHjQYK2PlGcMU5qz\">\n\u2461 \u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387 &gt; \u8bbe\u8ba1\u70ed\u8d1f\u8377 \u00d7 0.5\uff08\u6700\u5c0f\u529f\u7387\u9ad8\u4e8e\u9700\u6c42\u7684\u4e00\u534a\uff0c\u5fc5\u7136\u9891\u7e41\u542f\u505c\uff09\uff1b<br data-page-node-id=\"huc6A2aHh7AhlJHwAfA7jt\">\n\u2462 \u91c7\u6696\u9762\u79ef \u2264150\u33a1\uff0c\u5374\u9009\u4e86 \u226528kW \u7684\u4e24\u7528\u7089\uff08\u89e6\u72af\"\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\"\u7ea2\u7ebf\uff09\uff1b<br data-page-node-id=\"V7bxkF9AGDHD99F9qqMUGK\">\n\u2463 \u51b7\u51dd\u7089\u7cfb\u7edf\u672a\u914d\u7f6e\u5ba4\u5916\u6e29\u5ea6\u8865\u507f\u6216\u6c14\u5019\u8865\u507f\u529f\u80fd\u3002\n<\/div>\n\n<h3 data-page-node-id=\"KzMnOFE1QhyRED5dOtm909\">2.4\u3000\u5173\u4e8e\u7535\u5730\u6696\u4e0e\"\u77f3\u58a8\u70ef\"\u7684\u6280\u672f\u771f\u76f8<\/h3>\n\n<p data-page-node-id=\"nzfQavkAdemZxtzxPoLseE\">\u7535\u5730\u6696\u4e0d\u53ef\u66ff\u4ee3\u7684\u573a\u666f\u662f<strong data-page-node-id=\"Lebw5WbFoGZnIJyNPTm1EL\">\u5c40\u90e8\u5c0f\u9762\u79ef<\/strong>\uff08\u536b\u751f\u95f4\u30015\u201350\u33a1 \u8865\u5145\u91c7\u6696\uff09\uff0c\u5347\u6e29\u5feb\u3001\u514d\u7ef4\u62a4\u3002\u4f46\u4f5c\u4e3a\u5168\u5c4b\u4e3b\u529b\u70ed\u6e90\uff0c\u8fd0\u884c\u8d39\u662f\u71c3\u6c14\u7684 1.5\u20132 \u500d\u3002<\/p>\n\n<div class=\"lm-tip\" data-page-node-id=\"m267agrRxkltYM2xslE11q\">\n<strong data-page-node-id=\"n4NLa42KNQJzaufzu4nNq6\">\"\u77f3\u58a8\u70ef\u5730\u6696\"\u4e0d\u662f\u9ed1\u79d1\u6280<\/strong>\uff1a\u7535\u91c7\u6696\u6c38\u8fdc\u662f 1 \u5ea6\u7535\u6362 1 \u5ea6\u70ed\uff0c\u80fd\u6548\u6bd4\u4e0d\u53ef\u80fd\u7a81\u7834\u7269\u7406\u5b9a\u5f8b\uff0c\u6240\u8c13\"\u77f3\u58a8\u70ef\u7701\u7535\"\u662f\u8425\u9500\u6982\u5ff5\u3002\n\u53e6\u5916\uff0c\u7535\u70ed\u819c\u7c7b\u4ea7\u54c1\u5b58\u5728\u5c40\u90e8\u8fc7\u70ed\u4e0e\u63a5\u5934\u8001\u5316\u7684\u5b89\u5168\u98ce\u9669\uff0c\u9009\u62e9\u65f6\u52a1\u5fc5\u786e\u8ba4\u662f\u5426\u4e3a<strong data-page-node-id=\"7fb3cGdvVMe2WqFhCFE6Ph\">\u53cc\u5bfc\u53d1\u70ed\u7535\u7f06<\/strong>\uff08\u53ef\u62b5\u6d88\u78c1\u573a\uff09\u5e76\u7d22\u8981\u68c0\u6d4b\u62a5\u544a\u3002\n<\/div>\n\n<figure class=\"lm-fig\" data-page-node-id=\"CU5JpNkqSm3SgueECE3IDZ\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs-768x1024.jpg\" class=\"lmtall\" alt=\"\u6210\u90fd\u5929\u5e9c\u516c\u56ed\u672a\u6765\u57ce\u66fc\u745e\u5fb7\u5c0f\u5361\u51b7\u51dd\u7089\u5b89\u88c5\u5916\u89c2\u5168\u8c8c\u5b9e\u62cd\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-azzs-768x1024.jpg 768w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"768\" height=\"1024\">\n<figcaption data-page-node-id=\"nFiWL5SnebWdLIlHXnoqKA\">\u6210\u90fd\u5929\u5e9c\u516c\u56ed\u672a\u6765\u57ce \u00b7 \u674e\u8001\u5e08\u5bb6\uff1a\u66fc\u745e\u5fb7\u5c0f\u5361\u51b7\u51dd\u7089\u5b89\u88c5\u5168\u8c8c\uff08<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=5180\" data-page-node-id=\"Yza3a5Rq4IZ9FjKmPzs5Ab\">\u770b\u5b8c\u6574\u6848\u4f8b<\/a>\uff09<\/figcaption>\n<\/figure>\n\n<h2 data-page-node-id=\"XnCF52sBElDdupjCX6cdfE\">\u7b2c\u4e09\u7ae0\u3000\u8f93\u914d\uff1a\u51b3\u5b9a\"\u70ed\u80fd\u4e0d\u80fd\u9001\u5230\u6bcf\u4e2a\u623f\u95f4\"<\/h2>\n\n<h3 data-page-node-id=\"EJxeq1nnvk15Sg1YkOZgo8\">3.1\u3000\u76d8\u7ba1\u7ba1\u5f84\uff1aDe16 \u8fd8\u662f De20<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"UFNwDwtkBbLiVFalc4ChwN\"><table class=\"lm-tb\" data-page-node-id=\"0O1LCyYUrCtNsoHRDqTJDT\">\n<tbody><tr data-page-node-id=\"RjIbfEz5WonGRWaUZYvkGS\"><th style=\"width:14%\" data-page-node-id=\"EwaTmfAThdWuybBxlXh9Ai\">\u7ba1\u5f84<\/th><th style=\"width:24%\" data-page-node-id=\"tbE9lqbQUtGXYsQ8i06E1Y\">\u5e94\u7528\u573a\u666f<\/th><th style=\"width:20%\" data-page-node-id=\"NqM2ZA0f9DkEinhGGbWwZd\">\u6bcf\u56de\u8def\u6700\u5927\u9762\u79ef<\/th><th style=\"width:18%\" data-page-node-id=\"aW04knejKFI2gnlvUBUYxV\">\u6bcf\u56de\u8def\u957f\u5ea6<\/th><th data-page-node-id=\"L4nLTaEZ5D6BlEeGnOAsXD\">\u7279\u6027<\/th><\/tr>\n<tr data-page-node-id=\"0jACpKVAcjFeWBDcCHZ0dL\"><td data-page-node-id=\"UrPjAaFUxFW3pYDBGofFJ1\">De16\uff08\u5e38\u7528\uff09<\/td><td data-page-node-id=\"mIpPIvCjo3yjpNtzC6TUxK\">100\u33a1 \u4ee5\u4e0b\u4e2d\u5c0f\u6237\u578b<\/td><td data-page-node-id=\"5abCRAFzIpcNBCJunc2yfP\">\u7ea6 10\u33a1\uff08125mm \u95f4\u8ddd\uff09<\/td><td data-page-node-id=\"rdcNzAgNRqLzKbEqGEcFQt\">\u6700\u4f73 60\u201390m\uff0c\u6700\u5927 100m<\/td><td data-page-node-id=\"A0QRUqQV5DCSoi9IKDMabi\">\u6027\u4ef7\u6bd4\u9ad8\uff0c\u65bd\u5de5\u65b9\u4fbf<\/td><\/tr>\n<tr data-page-node-id=\"4edkNJaSOyrhEwOZNvHEQc\"><td data-page-node-id=\"hgQZE013ZgDb0r9Kyl2MAu\">De20\uff08\u63a8\u8350\uff09<\/td><td data-page-node-id=\"Uj9khx79LobC7GXdGzPujh\">100\u33a1 \u4ee5\u4e0a\u5927\u6237\u578b\u3001\u522b\u5885<\/td><td data-page-node-id=\"GqvNNvLEVO0CIXeC8WNcQC\">\u7ea6 20\u33a1\uff08200mm \u95f4\u8ddd\uff09<\/td><td data-page-node-id=\"HipYelDrlFI3O0cLjDDktC\">\u6700\u4f73 80\u2013110m\uff0c\u6700\u5927 120m<\/td><td data-page-node-id=\"XNVeomNVNKDp52HyhTdHJ4\">\u5927\u6d41\u91cf\u3001\u5c0f\u6e29\u5dee\uff0c\u7cfb\u7edf\u66f4\u7a33\u5b9a\uff0c\u53ef\u51cf\u5c11\u56de\u8def\u6570<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<p data-page-node-id=\"l84B1xZfkPATzsgn1ZBQh4\"><strong data-page-node-id=\"DOwkrnHac4GI6u4Sq1f5LL\">\u6838\u5fc3\u77e5\u8bc6\u70b9<\/strong>\uff1a\u5c0f\u6237\u578b\u7528 16 \u7ba1\uff0c\u5927\u5e73\u5c42\/\u522b\u5885\u7528 20 \u7ba1\uff0c\u4e24\u8005\u53ef\u6df7\u7528\uff08\u4e3b\u7ba1 20\u3001\u652f\u7ba1 16\uff09\u3002De20 \u80fd\u627f\u8f7d\u66f4\u5927\u70ed\u8d1f\u8377\uff0c\u4e14\u66f4\u4e0d\u6613\u5835\u585e\u3002<\/p>\n\n<div class=\"lm-warn\" data-page-node-id=\"ByPdwRLBLDb6qpvL20igHd\">\n<strong data-page-node-id=\"QJsvOMDdr1LMrvFxNgJSHW\">\u4e3a\u4ec0\u4e48\u56de\u8def\u4e0d\u80fd\u968f\u4fbf\u52a0\u957f<\/strong>\uff1a\u5355\u4e2a\u56de\u8def\u8d8a\u957f\uff0c\u672b\u7aef\u6e29\u5dee\u8d8a\u5927\u3001\u6cbf\u7a0b\u963b\u529b\u8d8a\u9ad8\u3002\u8d85\u8fc7\u4e0a\u8868\u7684\u4e0a\u9650\uff0c\n\u76f4\u89c2\u8868\u73b0\u5c31\u662f\"\u5206\u6c34\u5668\u524d\u51e0\u8def\u70ed\u3001\u540e\u51e0\u8def\u51c9\"\uff1b\u66f4\u9ebb\u70e6\u7684\u662f\uff0c\u540e\u671f\u518d\u52a0\u5faa\u73af\u6cf5\u4e5f\u6551\u4e0d\u56de\u6765\u2014\u2014\n\u56e0\u4e3a\u7ba1\u5f84\u548c\u957f\u5ea6\u5728\u8bbe\u8ba1\u9636\u6bb5\u5c31\u5df2\u7ecf\u5b9a\u6b7b\u4e86\uff0c\u56de\u586b\u4e4b\u540e\u518d\u6539\u5c31\u8981\u7838\u5730\u3002\n<\/div>\n\n\n<h3 data-page-node-id=\"EpjUFKlu1ZCgq2SgSG4Kvm\">3.2\u3000\u4e3b\u7ba1\uff1aDe25 \u8d70\u5929\u4e0b\u7684\u65f6\u4ee3\u5df2\u7ecf\u8fc7\u53bb<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"F8n4syzMmREqEJFD7Dh96w\"><table class=\"lm-tb\" data-page-node-id=\"iG2bn5a63BDs4FKhsbi4AS\">\n<tbody><tr data-page-node-id=\"vkiZNL1GC5vuDgGdbGC4mt\"><th style=\"width:22%\" data-page-node-id=\"FjWIrC9UanBaC8qWzRTayW\">\u4f9b\u6696\u9762\u79ef<\/th><th style=\"width:26%\" data-page-node-id=\"Duo0Vnt5nBydrNZq6NcNjr\">\u4e3b\u7ba1\u7ba1\u5f84\u5efa\u8bae<\/th><th data-page-node-id=\"lHa932hqQVefAGkBXxUulA\">\u4f9d\u636e<\/th><\/tr>\n<tr data-page-node-id=\"XSdVDQcemSUyx3AwIj09kc\"><td data-page-node-id=\"RIwnduF1CIB4GlKJlRMkLs\">100\u33a1 \u4ee5\u4e0b<\/td><td data-page-node-id=\"FdcooaL16GXM6QiIfFcjpV\">De32<\/td><td data-page-node-id=\"FyBMFsEfANJgUaPrXuzAwE\">\u9f99\u8109\u6807\u51c6\uff1aDe32 \u4e3b\u7ba1\u8d77\u6b65\uff0c\u4e0d\u56e0\u6237\u578b\u5c0f\u964d\u7ea7<\/td><\/tr>\n<tr data-page-node-id=\"C4oe3nv4zu743bg9Xz4Sbq\"><td data-page-node-id=\"wAi3kWXXEt3kHC4xgykwpM\">100\u2013150\u33a1<\/td><td data-page-node-id=\"JTPsohw6S5EozMfZIhMNoA\"><strong data-page-node-id=\"v0oP7MDGbiDkArdQdcTtO8\">De32<\/strong><\/td><td data-page-node-id=\"EMTfatRLIKkMUqnDVNKAfq\">\u4f18\u5148 De32\uff0c\u786e\u4fdd\u5927\u6d41\u91cf\uff0c\u907f\u514d\u540e\u671f\u52a0\u6cf5<\/td><\/tr>\n<tr data-page-node-id=\"IErBiKYPln1r4qgXuBCSza\"><td data-page-node-id=\"eoVDd2DmlLPvQY8qSFQNqT\">150\u33a1 \u4ee5\u4e0a<\/td><td data-page-node-id=\"8YdL3ozAlCmFj1AelsnXNJ\"><strong data-page-node-id=\"KARWD1QGEojboA7HDY1lFs\">De40<\/strong><\/td><td data-page-node-id=\"jkBANQC6vfyHZnjc7VqtLM\">\u5927\u9762\u79ef\u4e3b\u7ba1\u5fc5\u987b\u52a0\u7c97\uff0c\u5426\u5219\u8fdc\u7aef\u56de\u8def\u6d41\u91cf\u4e0d\u8db3<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-warn\" data-page-node-id=\"I6xNKahAYNErpg8mHp6Fuk\">\n<strong data-page-node-id=\"ruj9v95yeaCHyaZ57n6TiC\">\u4e3b\u7ba1\u5347\u7ea7\u662f\u5173\u952e<\/strong>\uff1aDe32 \u7684\u622a\u9762\u79ef\u662f De25 \u7684 1.6 \u500d\uff0c\u6d41\u91cf\u63d0\u5347 60% \u4ee5\u4e0a\u3002\n\u5f88\u591a\"\u672b\u7aef\u4e0d\u70ed\u3001\u9505\u7089\u566a\u97f3\u5927\"\u7684\u987d\u75be\uff0c\u6839\u56e0\u5c31\u662f<strong data-page-node-id=\"y39uMBwfbuYZFaBptnidz6\">\u4e3b\u7ba1\u592a\u7ec6\u3001\u8fd0\u529b\u4e0d\u8db3<\/strong>\uff0c\u800c\u4e0d\u662f\u9505\u7089\u529f\u7387\u4e0d\u591f\u3002\n<\/div>\n\n<h3 data-page-node-id=\"hWtLiR7vJ1M9SAt0j7jGne\">3.3\u3000\u8f85\u6750\uff1a\u770b\u4e0d\u89c1\u7684\u5730\u65b9\uff0c\u51b3\u5b9a\u4e86\u5411\u4e0b\u635f\u5931\u591a\u5c11\u70ed<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"3iY0FuVChuPLEgNWMtubty\"><table class=\"lm-tb\" data-page-node-id=\"ijvpWg81BoqF5rL5nG1xA8\">\n<tbody><tr data-page-node-id=\"CZucPLlgUwIZSju02pIYSm\"><th style=\"width:16%\" data-page-node-id=\"Gls7CR667F85tpFZGI9eqh\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th style=\"width:30%\" data-page-node-id=\"ogj4JiSlWHjAPO9AAUrOdb\">\u6324\u5851\u677f XPS\uff08\u9ed8\u8ba4\uff09<\/th><th data-page-node-id=\"q95bXJyU2FBrFMvuv8ktGO\">\u767d\u6676\u677f\uff08\u53ef\u9009\u5347\u7ea7\uff09<\/th><\/tr>\n<tr data-page-node-id=\"LkIrmDyIGL7TVKJGlPZtyg\"><td data-page-node-id=\"PalfP8nAvIS4mGP9yhCcVJ\">\u4ee3\u8868\u54c1\u724c<\/td><td data-page-node-id=\"rZLcUnpbSgGUzStTl2vrJq\">\u8bfa\u5c14<\/td><td data-page-node-id=\"DcoRq4oF7c6MJ2CbqkwoMF\">\u4f1f\u661f \/ \u7eff\u7fbd<\/td><\/tr>\n<tr data-page-node-id=\"HEo9iPHdRxEIvIkufcwH4q\"><td data-page-node-id=\"mSBz6fjW7WxYlzq7QLp7lI\">\u6838\u5fc3\u6750\u8d28<\/td><td data-page-node-id=\"W8mG6SDFLGhaeR78cdbrIx\">\u6324\u5851\u805a\u82ef\u4e59\u70ef<\/td><td data-page-node-id=\"OLt1Hr4WzxXYYjNz7bz0GF\">\u9ad8\u54c1\u8d28\u805a\u82ef\u4e59\u70ef\uff08\u7eaf\u5ea6\u66f4\u9ad8\uff09<\/td><\/tr>\n<tr data-page-node-id=\"IuIFIH1FRLrljz8BJoTHUT\"><td data-page-node-id=\"KXs7Y6NdcKWtGIQoN4ZFbu\">\u4e3b\u8981\u4f18\u52bf<\/td><td data-page-node-id=\"6WhTg6BcElBUlsCwLL91ES\">\u4ef7\u683c\u7ecf\u6d4e\uff0c\u6ee1\u8db3\u57fa\u672c\u4fdd\u6e29<\/td><td data-page-node-id=\"GHDhzfxOPy5edg9JRnGNWP\">\u4fdd\u6e29\u66f4\u4f18\u3001\u66f4\u73af\u4fdd\uff08\u4f4e VOC\uff09\u3001\u6297\u538b\u5f3a\u5ea6\u66f4\u9ad8<\/td><\/tr>\n<tr data-page-node-id=\"OlESvhssQAZjlVP6IuNoHO\"><td data-page-node-id=\"940mnQYTwOmQMHg9t5BoLK\">\u7532\u919b\u91ca\u653e\u91cf<\/td><td data-page-node-id=\"eBELggmfyY9PbNvbv8fHm1\">\u2014<\/td><td data-page-node-id=\"wQVKB4gYW93aGDVzXuSuZl\">\u7eff\u7fbd\u5b9e\u6d4b 0.021 mg\/m\u00b3\uff1b\u4f1f\u661f\u672a\u68c0\u51fa\uff08N.D.\uff09<\/td><\/tr>\n<tr data-page-node-id=\"jNLmrbjqrWMURX7e0EwaTP\"><td data-page-node-id=\"6JFAiHzSbFJCxiUYkmjCES\">TVOC \u91ca\u653e\u91cf<\/td><td data-page-node-id=\"pRdjSn94u6nbtR8dKxJDWg\">\u2014<\/td><td data-page-node-id=\"zhR1aDYUxV6Hnl0lyDr4Xt\">\u7eff\u7fbd\u5b9e\u6d4b 0.311 mg\/m\u00b3\uff1b\u4f1f\u661f\u672a\u68c0\u51fa\uff08N.D.\uff09<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-tip\" data-page-node-id=\"M12QEoDrUBjyKGcD0bNi0j\">\n<strong data-page-node-id=\"sGksIoKcx7K9UHKuEJ5RbA\">\u4e3a\u4ec0\u4e48\u4fdd\u6e29\u677f\u503c\u5f97\u52a0\u94b1<\/strong>\uff1a\u52a3\u8d28\u4fdd\u6e29\u677f\u4f1a\u5bfc\u81f4<strong data-page-node-id=\"ESp1QbAWO9U2utukDbFola\">\u5411\u4e0b\u70ed\u635f\u5931\u8d85\u8fc7 30%<\/strong>\u2014\u2014\u4f60\u70e7\u7684\u5929\u7136\u6c14\u6709\u4e09\u5206\u4e4b\u4e00\u5728\u52a0\u70ed\u697c\u4e0b\u7684\u5929\u82b1\u677f\u3002\n\u6309 JGJ 142-2012 \u7684\u5730\u9762\u5e73\u5747\u6e29\u5ea6\u6821\u6838\u516c\u5f0f <code data-page-node-id=\"OrwwiCqP22Rf4sVTnqB2NQ\">tpj = tn + 9.82 \u00d7 (q\/100)^0.969<\/code>\uff0c\n\u4fdd\u6e29\u5c42\u70ed\u963b\u8d8a\u5927\uff08\u5411\u4e0b\u635f\u5931\u8d8a\u5c0f\uff09\uff0c\u76f8\u540c\u4f9b\u6c34\u6e29\u5ea6\u4e0b\u4f20\u7ed9\u623f\u95f4\u7684\u6709\u6548\u70ed\u91cf\u8d8a\u9ad8\u3002\n<\/div>\n\n<figure class=\"lm-fig\" data-page-node-id=\"pswgLiLsvCjeCq9HMmW601\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-jsbps-768x1024.jpg\" class=\"lmtall\" alt=\"\u6210\u90fd\u9e93\u6e56\u6c84\u5cb8\u5730\u6696\u65bd\u5de5\u6324\u5851\u677f\u4fdd\u6e29\u5c42\u94fa\u8bbe\u5b9e\u62cd\uff0c\u4fdd\u6e29\u677f\u6ee1\u94fa\u65e0\u7a7a\u9699\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-jsbps-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-jsbps-768x1024.jpg 768w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"768\" height=\"1024\">\n<figcaption data-page-node-id=\"tF4zkctvvZ95pYktc7lFsA\">\u9e93\u6e56\u6c84\u5cb8 \u00b7 \u5f20\u8001\u5e08\u5bb6\uff1a\u6324\u5851\u677f\u4fdd\u6e29\u5c42\u94fa\u8bbe\u73b0\u573a\uff0c\u8981\u6c42\u6ee1\u94fa\u3001\u62fc\u7f1d\u4e25\u5bc6<\/figcaption>\n<\/figure>\n\n<figure class=\"lm-fig\" data-page-node-id=\"NaEDXNTsZYNzzlLvTEf5ax\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-01-768x1024.jpg\" class=\"lmtall\" alt=\"\u6210\u90fd\u9e93\u6e56\u6c84\u5cb8\u5730\u6696\u53cd\u5c04\u819c\u94fa\u8bbe\u65bd\u5de5\u5b9e\u62cd\uff0c\u642d\u63a5\u5904\u538b\u8fb9\u5904\u7406\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-01-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-01-768x1024.jpg 768w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"768\" height=\"1024\">\n<figcaption data-page-node-id=\"mQg8fJ4Bx2ETrhBwD7Gtcv\">\u53cd\u5c04\u819c\u94fa\u8bbe\uff1a\u642d\u63a5\u5904\u9700\u538b\u8fb9\uff0c\u907f\u514d\u6d47\u7b51\u65f6\u79fb\u4f4d<\/figcaption>\n<\/figure>\n\n<h3 data-page-node-id=\"BilyvHet4ETU6eriqSfIqy\">3.4\u3000\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u505a\u4e8c\u6b21\u7cfb\u7edf<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"maLB6svVmqP7jK994xCkRb\"><table class=\"lm-tb\" data-page-node-id=\"Hr1uJj09qaykbehIxrlJDt\">\n<tbody><tr data-page-node-id=\"eQvEFVLFmOeVr0xQ0RLDoD\"><th style=\"width:20%\" data-page-node-id=\"DUnC5Pdy8eYaBi8ya3mtMk\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th style=\"width:30%\" data-page-node-id=\"xuCveKzeH9JWPXZ6qraipX\">\u58c1\u6302\u7089\uff08\u5e38\u89c4\/\u51b7\u51dd\uff09<\/th><th style=\"width:28%\" data-page-node-id=\"lbpSpTCpMvw1G46J8Ixtrq\">\u7a7a\u6c14\u80fd\uff08\u5168\u53d8\u9891\u70ed\u6cf5\uff09<\/th><th data-page-node-id=\"Dlfs2Ty6T71DBE72YQsvCD\">\u7ed3\u8bba<\/th><\/tr>\n<tr data-page-node-id=\"M7AeExtKyFDvA0BBQW5900\"><td data-page-node-id=\"bE3r6XoaXnED243kFnjXVG\">\u4e3b\u673a\u529f\u7387<\/td><td data-page-node-id=\"RZajLtnTjkGLkI0Wq3lIhr\"><strong data-page-node-id=\"BG6a4NbUAx2PQfW6XG2FKG\">\u4e25\u91cd\u8fc7\u5269<\/strong>\uff0c24kW \u662f\u5e38\u89c1\u8d77\u6b65<\/td><td data-page-node-id=\"ApBpfyNeYGjD7FORF6VADV\"><strong data-page-node-id=\"eDhwtFFIWAEdsDRk5ts3C7\">\u7cbe\u51c6\u5339\u914d<\/strong>\uff0c12.5kW \u5339\u914d 100\u33a1<\/td><td data-page-node-id=\"oFn1TEmVIMHyyaXCAdAm1A\">\u58c1\u6302\u7089\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u662f\u6839\u6e90<\/td><\/tr>\n<tr data-page-node-id=\"FsNmrOU9uP0b7nEST16SEI\"><td data-page-node-id=\"mVTvepElBkJlUw7RJXREDe\">\u5185\u7f6e\u6c34\u6cf5<\/td><td data-page-node-id=\"cq8vqjuyj4ZF4FAIUIrycc\">\u5c0f\u5b9a\u9891\u6cf5\uff0c\u5b9e\u9645\u6d41\u91cf\u4ec5 700\u2013900L\/h<\/td><td data-page-node-id=\"9htFqn2An9pXMoUzetUPr1\">\u53d8\u9891\u6cf5\uff0c\u968f\u4e3b\u673a\u81ea\u52a8\u8c03\u8282<\/td><td data-page-node-id=\"VvrtQ4mrHo346v0OcwFlWK\">\u58c1\u6302\u7089\"\u8fd0\u529b\"\u4e25\u91cd\u4e0d\u8db3<\/td><\/tr>\n<tr data-page-node-id=\"OCDid3BB3wkFJI1DCfrDFC\"><td data-page-node-id=\"7RTXarfuH1AmGJXGabsVI4\">\u6838\u5fc3\u77db\u76fe<\/td><td data-page-node-id=\"xY4myuhuzAJuvIm201uFzF\">\u529f\u7387\u5927 + \u6d41\u91cf\u5c0f \u2192 \u9891\u7e41\u542f\u505c\u3001\u65e0\u6548\u4ea7\u70ed<\/td><td data-page-node-id=\"opxYncKRxFoa5Ab1wK8GRN\">\u529f\u7387\u5339\u914d + \u6d41\u91cf\u81ea\u8c03 \u2192 \u8fde\u7eed\u8fd0\u884c<\/td><td data-page-node-id=\"aeAlo2alD5xcChcHEKmEtS\">\u58c1\u6302\u7089\u9700\u8981\u4e8c\u6b21\u7cfb\u7edf\"\u89e3\u8026\"<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<p data-page-node-id=\"4OXDofX0rFKygVG2BRLx1a\">\u7b80\u5355\u8bf4\uff1a<strong data-page-node-id=\"KCY5OkIjEVd1CqH9LNkJEv\">100\u33a1 \u4ee5\u4e0a\u7684\u58c1\u6302\u7089\u5730\u6696\uff0c\u5efa\u8bae\u505a\u4e8c\u6b21\u7cfb\u7edf<\/strong>\uff08\u4e00\u6b21\u4fa7\u9505\u7089\u5faa\u73af + \u4e8c\u6b21\u4fa7\u5206\u5ba4\u6e29\u63a7\u5faa\u73af\u901a\u8fc7\u8026\u5408\u7f50\/\u677f\u6362\u89e3\u8026\uff09\uff0c\u8ba9\u9505\u7089\u7684\"\u5927\u6d41\u91cf\u9700\u6c42\"\u548c\u672b\u7aef\u7684\"\u5c0f\u6d41\u91cf\u9700\u6c42\"\u4e92\u4e0d\u5e72\u6270\u3002\u7a7a\u6c14\u80fd\u5168\u53d8\u9891\u7cfb\u7edf\u4e00\u822c\u4e0d\u5fc5\u8981\u3002<\/p>\n\n<figure class=\"lm-fig\" data-page-node-id=\"yccM9pw3NxF2Q2QqguUQlT\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lqhdlz-lls-jfsqaz-qm-03.jpg\" alt=\"\u6210\u90fd\u9f99\u6cc9\u6052\u5927\u7eff\u6d32\u5730\u6696\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5168\u8c8c\u5b9e\u62cd\uff0c\u5404\u56de\u8def\u72ec\u7acb\u63a7\u5236\" loading=\"lazy\" width=\"960\" height=\"720\">\n<figcaption data-page-node-id=\"L6MAgU06BnWyN1ggvZg0F0\">\u9f99\u6cc9\u6052\u5927\u7eff\u6d32 \u00b7 \u674e\u8001\u5e08\u5bb6\uff1a\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5168\u8c8c\uff0c\u6bcf\u4e2a\u56de\u8def\u72ec\u7acb\u63a7\u5236\uff08\u4e25\u7981\u5f02\u7a0b\u4e32\u8054\uff09<\/figcaption>\n<\/figure>\n\n<h3 data-page-node-id=\"z7LIP2I9dJaQwCvsFlsFx7\">3.5\u3000\u7ba1\u6750\u6750\u8d28\uff1aPE-RT I\u3001PE-RT II \u4e0e PE-Xa \u600e\u4e48\u9009<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"WLGYDUjvlPJCudqV9bGFyx\"><table class=\"lm-tb\" data-page-node-id=\"vZyZgs5B84W1EgZlIHA8GD\">\n<tbody><tr data-page-node-id=\"WuRYEVaqrUnC94MVXm0x0I\"><th style=\"width:18%\" data-page-node-id=\"w4ZHWlmlBwNanwBzD5Wpu8\">\u7ba1\u6750\u7c7b\u578b<\/th><th style=\"width:30%\" data-page-node-id=\"GResIdwC5CpOpmPplKzZA7\">\u7279\u70b9<\/th><th style=\"width:18%\" data-page-node-id=\"VeM7vtjCEI1duSO3Pir8nT\">\u9002\u7528\u6c34\u6e29<\/th><th data-page-node-id=\"GzipscYVy42T5GMQtMdDaU\">\u5730\u6696\u9002\u7528\u6027<\/th><\/tr>\n<tr data-page-node-id=\"ApEMHBoRYKXqp27vRY5jJS\"><td data-page-node-id=\"pBW4wtC0Ms8lJoZCQQHNYw\"><strong data-page-node-id=\"u1q5NXU1lvXuMcsA8loEEL\">PE-RT I \u578b<\/strong><\/td><td data-page-node-id=\"SwFShD0qolYTmfqubxC4gM\">\u67d4\u97e7\u6027\u597d\uff0c\u6563\u70ed\u6027\u4f18\uff0c\u53ef\u70ed\u7194\u8fde\u63a5<\/td><td data-page-node-id=\"RY3H7p5QPi24AGKHLjKunV\">60\u2103 \u4ee5\u4e0b<\/td><td data-page-node-id=\"cCkkEWdyDDdUjZzGYbxmug\"><strong data-page-node-id=\"NaRzFpwYJMG0cTTOKYGNMs\">\u5730\u6696\u76d8\u7ba1\u9996\u9009<\/strong><\/td><\/tr>\n<tr data-page-node-id=\"u1RXPzdvQfaCpqE0QZooFM\"><td data-page-node-id=\"q3B2Su9203onv2XqiKKgAY\">PE-RT II \u578b<\/td><td data-page-node-id=\"WVHyUXqtQduffBW4CxXPsy\">\u8010\u9ad8\u6e29\u6027\u80fd\u66f4\u5f3a<\/td><td data-page-node-id=\"aSQpjGNm2K3W1fCG2nrahL\">80\u2103 \u4ee5\u4e0b<\/td><td data-page-node-id=\"jgNCEEDwDNeX53kGNesVGc\">\u53ef\u7528\uff0c\u5bf9\u5730\u6696\u800c\u8a00\u6027\u80fd\u8fc7\u5269<\/td><\/tr>\n<tr data-page-node-id=\"Dm4ImII7gYt6jpDsq1yXRP\"><td data-page-node-id=\"aVpMkEiIx6zfy8mzOizuCZ\">PE-Xa<\/td><td data-page-node-id=\"n3AtS9AxV4t0N8JEz0r4tt\">\u6709\u8bb0\u5fc6\u529f\u80fd\uff0c\u8010\u9ad8\u6e29\u9ad8\u538b<\/td><td data-page-node-id=\"25xbF4G4NyacnszFWrQlYM\">95\u2103 \u4ee5\u4e0b<\/td><td data-page-node-id=\"FrmbfkDFtzEpMgcBifs3Qb\">\u591a\u7528\u4e8e\u9ad8\u6e29\u5de5\u51b5\uff0c\u5730\u6696\u975e\u5fc5\u9700<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-key\" data-page-node-id=\"x8uldCuLWI6czWDtvuOibc\">\n<strong data-page-node-id=\"Bb0kmZb4hyGGgO6UY9XKpP\">\u963b\u6c27\u5fc5\u987b\"\u5168\u7cfb\u7edf\u7edf\u4e00\"<\/strong>\uff1a\u4e00\u534a\u963b\u6c27\u3001\u4e00\u534a\u4e0d\u963b\u6c27\uff0c\u7b49\u4e8e\u767d\u505a\u3002\u6c27\u6c14\u4f1a\u4ece\u4e0d\u963b\u6c27\u7684\u90a3\u6bb5\u7ba1\u6e17\u8fdb\u6765\uff0c\n\u6574\u4e2a\u7cfb\u7edf\u7167\u6837\u5b58\u5728\u6c27\u5316\u8150\u8680\u98ce\u9669\u2014\u2014\u5206\u96c6\u6c34\u5668\u3001\u9505\u7089\u677f\u6362\u3001\u6c34\u6cf5\u90fd\u4f1a\u53d7\u5f71\u54cd\u3002\n\u5224\u65ad\u65b9\u6cd5\u5f88\u7b80\u5355\uff1a\u770b\u7ba1\u8eab\u662f\u5426\u6709 <strong data-page-node-id=\"wdHhF3HM0ADpw7kdMrKQ6e\">EVOH \u963b\u6c27\u5c42<\/strong>\u6807\u8bc6\uff0c\u5e76\u628a\u7ba1\u6750\u54c1\u724c\u3001\u578b\u53f7\u3001\u963b\u6c27\u7b49\u7ea7\u5199\u8fdb\u5408\u540c\u9644\u4ef6\u3002\n<\/div>\n\n<p data-page-node-id=\"dbPKXmIanvTaHkYEiM7De2\">\u60f3\u770b\u4e0d\u540c\u7ba1\u6750\u5728\u771f\u5b9e\u5de5\u5730\u4e0a\u7684\u5dee\u522b\uff0c\u53ef\u4ee5\u770b<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" data-page-node-id=\"GCx0Iae8LTkGW6Np15YsAS\">\u5730\u6696\u77e5\u8bc6\u5e95\u5ea7 \u00b7 \u5b8c\u6574\u7248<\/a>\u91cc\u7684\u65bd\u5de5\u5b9e\u5f55\u7167\u7247\u3002<\/p>\n\n<h2 data-page-node-id=\"vnFNC2WF0yqVntQCzmyOWP\">\u7b2c\u56db\u7ae0\u3000\u672b\u7aef\u4e0e\u63a7\u5236\uff1a\u628a\u70ed\u91cf\u4ea4\u5230\u623f\u95f4\u91cc<\/h2>\n\n<h3 data-page-node-id=\"G3RAeexCpGBvtKUvcxXIvM\">4.1\u3000\u56de\u586b\u5c42\uff1a\u6e7f\u6cd5\u4e0e\u5e72\u6cd5<\/h3>\n\n<p data-page-node-id=\"nF1EPH67AzZAS3PCsONUtY\">\u6e7f\u6cd5\uff08\u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b\uff09\u662f\u6210\u90fd\u4e3b\u6d41\u505a\u6cd5\uff0c\u84c4\u70ed\u597d\u3001\u5730\u9762\u6e29\u5ea6\u5747\u5300\uff0c\u4ee3\u4ef7\u662f\u5c42\u9ad8\u5360\u7528\u7ea6 5\u20137cm\u3001\u9700\u8981\u517b\u62a4\u671f\u3002\u5e72\u6cd5\uff08\u9884\u5236\u6c9f\u69fd\u677f\uff09\u5c42\u9ad8\u5360\u7528\u5c0f\u3001\u5347\u6e29\u5feb\uff0c\u4f46\u84c4\u70ed\u5dee\u3001\u811a\u611f\u504f\u786c\uff0c\u9002\u5408\u5c42\u9ad8\u7d27\u5f20\u6216\u540e\u671f\u52a0\u88c5\u573a\u666f\u3002<\/p>\n\n<p data-page-node-id=\"uQLSGET9EkiGdFM1OwQI1a\">\u56de\u586b\u5c42\u65bd\u5de5\u540e\u5fc5\u987b<strong data-page-node-id=\"43k5Dsbf5pbDNAUabCaGSQ\">\u81ea\u7136\u517b\u62a4 7 \u5929<\/strong>\uff0c\u671f\u95f4\u4e25\u7981\u8e29\u8e0f\u548c\u642c\u8fd0\u91cd\u7269\uff1b7 \u5929\u540e\u624d\u53ef\u8fdb\u884c\u5730\u9762\u627e\u5e73\u65bd\u5de5\u3002\u9996\u6b21\u5f00\u542f\u5730\u6696\u65f6\uff0c\u4f9b\u6c34\u6e29\u5ea6\u8981<strong data-page-node-id=\"ISAcoH1yJdwbWRUVbqnAJy\">\u9636\u68af\u5f0f\u5347\u6e29<\/strong>\uff08\u6bcf\u5929\u5347 5\u2103 \u5de6\u53f3\uff09\uff0c\u907f\u514d\u56de\u586b\u5c42\u56e0\u9aa4\u70ed\u5f00\u88c2\u3002<\/p>\n\n<h3 data-page-node-id=\"6noPeGxWr1v9GCsgTrfpoB\">4.2\u3000\u63a7\u5236\uff1a\u6c34\u6e29\u63a7\u5236 vs \u5ba4\u6e29\u63a7\u5236<\/h3>\n\n<div class=\"lm-warn\" data-page-node-id=\"W8SB263O7re4j0JtjCdyLF\">\n<strong data-page-node-id=\"6RuNkkMA0CIWQETVibEK6r\">\u8fd9\u662f\u5730\u6696\u6700\u5bb9\u6613\u88ab\u5077\u5de5\u51cf\u6599\u7684\u4e00\u73af\u3002<\/strong><br data-page-node-id=\"U5Au7SNNSmkMbYps8ASAqd\">\n\u666e\u901a\u58c1\u6302\u7089\u7684\u539f\u751f\u903b\u8f91\u662f<strong data-page-node-id=\"VG79sDcQoMLgeFxu69qGeF\">\u63a7\u5236\u51fa\u6c34\u6e29\u5ea6<\/strong>\u2014\u2014\u5b83\u53ea\u77e5\u9053\"\u628a\u6c34\u70e7\u5230 50\u2103\"\uff0c\u4e0d\u77e5\u9053\"\u623f\u95f4\u73b0\u5728\u51e0\u5ea6\"\u3002\n\u7ed3\u679c\u5c31\u662f\uff1a\u5ba4\u6e29\u65e9\u5c31\u5230 22\u2103 \u4e86\uff0c\u9505\u7089\u8fd8\u5728\u6309\u6c34\u6e29\u903b\u8f91\u7ee7\u7eed\u70e7\uff0c\u8fd9\u5c31\u662f<strong data-page-node-id=\"Mo7AWpO3NwftZUJ2ZDnw0p\">\u65e0\u6548\u4ea7\u70ed<\/strong>\uff0c\u4e5f\u662f\"\u5730\u6696\u8d39\u6c14\"\u7684\u5934\u53f7\u539f\u56e0\u3002\n<\/div>\n\n<p data-page-node-id=\"nZNMUxOUClybpoKpuo5YOg\">\u6b63\u786e\u7684\u505a\u6cd5\u662f<strong data-page-node-id=\"8geZWer6ScXTomoF7nfGBf\">\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/strong>\uff1a\u6bcf\u4e2a\u623f\u95f4\u88c5\u6e29\u63a7\u5668\uff0c\u5ba4\u6e29\u8fbe\u6807\u540e\u5173\u95ed\u8be5\u56de\u8def\u7535\u70ed\u6267\u884c\u5668\uff1b\u5206\u96c6\u6c34\u5668\u4e0a\u7684\u4e2d\u592e\u8054\u52a8\u63a7\u5236\u5668\u6c47\u603b\u5404\u623f\u95f4\u4fe1\u53f7\uff0c\u5168\u90e8\u8fbe\u6807\u540e\u7ed9\u9505\u7089\u53d1\u505c\u673a\u4fe1\u53f7\u3002\u9505\u7089\u6536\u5230\u4fe1\u53f7\u624d\u771f\u6b63\u505c\u706b\u3002<\/p>\n\n<figure class=\"lm-fig\" data-page-node-id=\"7zC0Pukr7fw8mwWGBdzH25\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lqhdlz-lls-jfsqaz-ldkzqaz-02.jpg\" alt=\"\u6210\u90fd\u9f99\u6cc9\u6052\u5927\u7eff\u6d32\u5730\u6696\u5206\u96c6\u6c34\u5668\u8054\u52a8\u63a7\u5236\u5668\u5b89\u88c5\u5b9e\u62cd\uff0c\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\" loading=\"lazy\" width=\"960\" height=\"720\">\n<figcaption data-page-node-id=\"dehaMpsuHyxuEylabJCdkv\">\u5206\u96c6\u6c34\u5668\u8054\u52a8\u63a7\u5236\u5668\uff1a\u628a\u5404\u623f\u95f4\u6e29\u63a7\u4fe1\u53f7\u6c47\u603b\u540e\u63a7\u5236\u9505\u7089\u542f\u505c<\/figcaption>\n<\/figure>\n\n<figure class=\"lm-fig\" data-page-node-id=\"Abhq06KHWeCpNOiNFrznFC\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-cxglf-768x1024.jpg\" class=\"lmtall\" alt=\"\u6210\u90fd\u5929\u5e9c\u516c\u56ed\u672a\u6765\u57ce\u51b7\u51dd\u7089\u5730\u6696\u78c1\u6027\u8fc7\u6ee4\u5668\u5b89\u88c5\u5b9e\u62cd\uff0c\u9632\u6b62\u7cfb\u7edf\u6742\u8d28\u5835\u585e\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-cxglf-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfgywlc-lls-cxglf-768x1024.jpg 768w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"768\" height=\"1024\">\n<figcaption data-page-node-id=\"fKe9piqxwg4pfUsFtAnerp\">\u78c1\u6027\u8fc7\u6ee4\u5668\uff1a\u62e6\u622a\u7cfb\u7edf\u5185\u7684\u94c1\u78c1\u6027\u6742\u8d28\uff0c\u662f\u4fdd\u62a4\u58c1\u6302\u7089\u548c\u5206\u96c6\u6c34\u5668\u7684\u4f4e\u6210\u672c\u9ad8\u56de\u62a5\u914d\u7f6e<\/figcaption>\n<\/figure>\n\n<h3 data-page-node-id=\"tGNdxTf0aY450KRYyq3KLi\">4.3\u3000\u4e09\u79cd\u63a7\u5236\u65b9\u5f0f\uff0c\u8282\u80fd\u5dee\u591a\u5c11<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"n4rIyI4SNxAKqYKKYhJztf\"><table class=\"lm-tb\" data-page-node-id=\"FieNMIjonsvlJvB29MSBLX\">\n<tbody><tr data-page-node-id=\"SmTXf7Q1LGo9IehDfB0bIy\"><th style=\"width:24%\" data-page-node-id=\"gexVAHQtMUo21AuoHqXExe\">\u63a7\u5236\u65b9\u5f0f<\/th><th style=\"width:22%\" data-page-node-id=\"A7vD8K3fnTdLi5L1zg3acY\">\u8282\u80fd\u6548\u679c<\/th><th data-page-node-id=\"Cj1n0BlbS7zwGFRM5cFzRD\">\u63a8\u8350\u573a\u666f<\/th><\/tr>\n<tr data-page-node-id=\"Z3Crp74dFnq6x6dR625ZnG\"><td data-page-node-id=\"KQiOIY4bZauM7kwwXNkawi\">\u6e29\u63a7\u9600\u63a7\u5236<\/td><td data-page-node-id=\"Zv35A4xWV5JXyc2fCfuxLX\">5\u201310%<\/td><td data-page-node-id=\"UG6X5rzrCMfz3KC0UHcAau\">\u57fa\u7840\u5206\u5ba4\u63a7\u6e29\uff0c\u9884\u7b97\u6709\u9650\u65f6\u7684\u5e95\u7ebf\u914d\u7f6e<\/td><\/tr>\n<tr data-page-node-id=\"hnpOxRN1D01QHE4yrYWlet\"><td data-page-node-id=\"4umyT2n1Mm4c4ql5CSupxJ\"><strong data-page-node-id=\"C8tUrtVe76hT9Ng4SMXR57\">\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/strong><\/td><td data-page-node-id=\"h0hEgVMjG293fn4VBQkNeT\"><strong data-page-node-id=\"2tjbEFUZ4PWUupfxZ5jUGF\">10\u201325%<\/strong><\/td><td data-page-node-id=\"smm9mXOp3ISXjeEBfqTXVU\"><strong data-page-node-id=\"bwheCmfdujAtb2RZmU8rB8\">\u63a8\u8350\u6807\u914d<\/strong>\uff0c\u6210\u90fd\u5bb6\u5ead\u5730\u6696\u7684\u4e3b\u6d41\u9009\u62e9<\/td><\/tr>\n<tr data-page-node-id=\"o9EvIKHFXUPDLXj6ORLT1V\"><td data-page-node-id=\"lZUHeJWC4mgCoYvsbICSjF\">\u667a\u80fd\u96c6\u63a7\u7cfb\u7edf<\/td><td data-page-node-id=\"n0BKGHjVwvf7FltCkPkMvw\">15\u201330%<\/td><td data-page-node-id=\"CiLf8FffeVqTwUFjTm4DBO\">\u5927\u6237\u578b \/ \u522b\u5885\uff0c\u623f\u95f4\u591a\u3001\u4f7f\u7528\u65f6\u95f4\u9519\u5f00<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<p data-page-node-id=\"uPWHQUe624letuHF21klbo\">\u4e09\u79cd\u65b9\u5f0f\u4e0d\u662f\"\u8d35\u7684\u5c31\u662f\u597d\u7684\"\uff0c\u5173\u952e\u770b\u4f60\u5bb6<strong data-page-node-id=\"6T8rDnyp0xnUdZqTdlfa9O\">\u623f\u95f4\u7684\u4f7f\u7528\u65f6\u95f4\u662f\u5426\u9519\u5f00<\/strong>\u3002\n\u4e24\u53e3\u4e4b\u5bb6\u3001\u5168\u5c4b\u540c\u65f6\u5f00\u540c\u65f6\u5173\uff0c\u5ba4\u6e29\u8054\u52a8\u5c31\u591f\u7528\uff1b\u4e09\u4ee3\u540c\u5802\u3001\u8001\u4eba\u623f\u5168\u5929\u5f00\u3001\u4e66\u623f\u53ea\u6709\u665a\u4e0a\u7528\uff0c\u667a\u80fd\u96c6\u63a7\u624d\u5212\u5f97\u6765\u3002\n\u63a7\u5236\u672c\u8eab\u4e0d\u4ea7\u70ed\uff0c\u5b83\u53ea\u662f\u51b3\u5b9a\"\u8be5\u70e7\u7684\u65f6\u5019\u70e7\u3001\u4e0d\u8be5\u70e7\u7684\u65f6\u5019\u522b\u70e7\"\u3002<\/p>\n\n\n<h2 data-page-node-id=\"12CX75Oh8QzurCQjKx10OO\">\u7b2c\u4e94\u7ae0\u3000\u8bbe\u8ba1\u89c4\u8303\uff1a\u56fd\u6807\u600e\u4e48\u8bf4\u7684<\/h2>\n\n<h3 data-page-node-id=\"hiXDCNWB3yAsh3dAe8KcYU\">5.1\u3000\u4e09\u672c\u5fc5\u987b\u9075\u5b88\u7684\u6807\u51c6<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"IPhvxUUa5QoXHLKXvBYBmK\"><table class=\"lm-tb\" data-page-node-id=\"pew4Hx6vqR2WioUjr3Nmoy\">\n<tbody><tr data-page-node-id=\"DTrdG6AIPB6ylnkr5w8FJn\"><th style=\"width:20%\" data-page-node-id=\"TfZ46sEmqFHceACgNKnOQT\">\u6807\u51c6\u53f7<\/th><th style=\"width:38%\" data-page-node-id=\"HdrqUMV8CItIyOeOPC2lyJ\">\u540d\u79f0<\/th><th data-page-node-id=\"6Xzn4ZX7AhpFpj4jUCObWS\">\u6838\u5fc3\u5185\u5bb9<\/th><\/tr>\n<tr data-page-node-id=\"JBAIpIc29GDTduhfdv1vJ5\"><td data-page-node-id=\"NX8CG9C6vqV0Lw9W8Ffnnl\">GB 50736-2012<\/td><td data-page-node-id=\"2dAROsiRhLbnRd87OcAZZS\">\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><td data-page-node-id=\"FpHDKFJdoReEITt8wNknRD\">\u4f9b\u6696\u70ed\u8d1f\u8377\u8ba1\u7b97\u3001\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea6<\/td><\/tr>\n<tr data-page-node-id=\"hG9AhfJaEO8lcrIAGhMjS7\"><td data-page-node-id=\"VfdLdLz9NXMVGsDJDaTLyc\">JGJ 142-2012<\/td><td data-page-node-id=\"CDqqhvIBJBSWRcMOfSNwUj\">\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td><td data-page-node-id=\"L2SLP1GeOwm0iGY6yrhMzZ\">\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\/\u957f\u5ea6\/\u6c34\u6e29\/\u5730\u9762\u6e29\u5ea6<\/td><\/tr>\n<tr data-page-node-id=\"3b8j2mYEABj6zKBWYigygO\"><td data-page-node-id=\"Yc8cGoijeeH4BHUrMUUhOj\">GB 50242-2002<\/td><td data-page-node-id=\"dYy7nOk5DxByKG3VfoTM2d\">\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303<\/td><td data-page-node-id=\"4zNYbceTKsUpmvsmtn59hb\">\u6253\u538b\u9a8c\u6536\u6807\u51c6<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<h2>\u8bbe\u8ba1\u6280\u672f\u4f9d\u636e\uff1a\u9f99\u8109\u4f01\u4e1a\u8bbe\u8ba1\u6807\u51c6\uff08\u53c2\u6570\u901f\u67e5\u4e0e\u53e3\u5f84\u58f0\u660e\uff09<\/h2>\n<p>\u672c\u8282\u628a\u5168\u7ad9\u5730\u6696\u8bbe\u8ba1\u53c2\u6570\u5f52\u4e00\u5230\u300c\u9f99\u8109\u4f01\u4e1a\u8bbe\u8ba1\u6807\u51c6\u300d\uff0c\u662f\u9f99\u8109\u5bf9\u5916\u5185\u5bb9\u7684\u552f\u4e00\u771f\u503c\u6e90\u3002\u51e1\u51fa\u73b0\u7ba1\u5f84\u3001\u95f4\u8ddd\u3001\u6c34\u6e29\u3001\u4e8c\u6b21\u7cfb\u7edf\u3001\u6c2f\u79bb\u5b50\u7b49\u53c2\u6570\uff0c\u4ee5\u672c\u8282\u4e3a\u51c6\uff0c\u7981\u6b62\u51ed\u5370\u8c61\u5199\u51fa\u591a\u4e2a\u7248\u672c\uff08\u5982\u76d8\u7ba1\u957f\u5ea6 150m\/120m\u3001\u6c2f\u79bb\u5b50\u2264100\/\u56fd\u6807\u2264250 \u6253\u67b6\uff09\u3002<\/p>\n<table>\n<thead><tr><th>\u53c2\u6570<\/th><th>\u9f99\u8109\u4f01\u4e1a\u6807\u51c6\u53e3\u5f84<\/th><th>\u6807\u51c6\u51fa\u5904<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e3b\u7ba1\u7ba1\u5f84<\/td><td>\u5730\u6696\uff0f\u6c34\u7cfb\u7edf\u4e3b\u7ba1 \u2265 De32 \u8d77\u6b65\uff0c\u5927\u8d1f\u8377\u5347 De40\uff1b\u652f\u7ba1 \u2265 De20<\/td><td>JGJ 142-2012<\/td><\/tr>\n<tr><td>\u76d8\u7ba1\u4e0e\u95f4\u8ddd<\/td><td>De16 \u95f4\u8ddd 125mm\uff08\u7ea6 10\u33a1\/\u56de\u8def\uff09\u3001De20 \u95f4\u8ddd 200mm\uff08\u7ea6 20\u33a1\/\u56de\u8def\uff09\uff0c\u6309\u6d41\u91cf\u4e0e 10\u2103 \u6e29\u5dee\u5339\u914d 100W\/\u33a1 \u70ed\u503c\u6838\u7b97<\/td><td>JGJ 142-2012<\/td><\/tr>\n<tr><td>\u5355\u8def\u957f\u5ea6<\/td><td>De16 \u5355\u8def \u2264100m\u3001De20 \u2264120m\uff08\u4e0d\u662f\u7f51\u4e0a\u5e38\u89c1\u7684 150m\uff09<\/td><td>JGJ 142-2012<\/td><\/tr>\n<tr><td>\u6c34\u6e29\u4e0e\u5730\u9762<\/td><td>\u4f9b\u6c34 35\u201345\u2103\u3001\u5730\u9762\u8868\u9762\u6e29\u5ea6 \u226428\u2103\uff0c\u4e0d\u505a\u9ad8\u6e29\u76f4\u4f9b<\/td><td>JGJ 142-2012<\/td><\/tr>\n<tr><td>\u4e8c\u6b21\u7cfb\u7edf<\/td><td><strong>\u5efa\u8bae\u4e0a\uff0c\u6309\u6d41\u91cf\u6838\u7b97<\/strong>\uff0c\u4e0d\u62ff\"\u5fc5\u987b\"\u5413\u4eba\uff08\u5185\u7f6e\u6cf5\u7ea6 800 L\/h\u300110\u2103 \u6e29\u5dee\u8986\u76d6\u7ea6 100\u33a1\uff0f10kW\uff0c\u8d85\u51fa\u6216\u5e38\u5206\u533a\u5f00\u5173\u624d\u5efa\u8bae\u4e0a\uff09<\/td><td>\u9f99\u8109\u4f01\u4e1a\u6807\u51c6<\/td><\/tr>\n<tr><td>\u9884\u6df7\u4e2d\u5fc3<\/td><td>\u975e\u51b7\u51dd\u7089\u4f5c\u5730\u6696\u70ed\u6e90<strong>\u5efa\u8bae\u52a0<\/strong>\uff0c\u907f\u514d\u4f4e\u6e29\u51b7\u51dd\u6c34\u7089\u5c3e\u8150\u8680\uff08\"\u5efa\u8bae\u52a0\"\uff0c\u975e\u5f3a\u884c\u5fc5\u505a\uff09<\/td><td>\u9f99\u8109\u4f01\u4e1a\u6807\u51c6<\/td><\/tr>\n<tr><td>\u6c2f\u79bb\u5b50<\/td><td>\u56fd\u6807 GB\/T 29044\uff1a\u94a2\u5236 Cl\u207b \u8865\u5145\u6c34\u2264250\u3001\u5faa\u73af\u6c34\u2264250 mg\/L\uff1b<strong>\u9f99\u8109\u5efa\u8bae\u63a7\u5236\u94a2\u5236\u2264100 mg\/L<\/strong>\uff08\u5382\u5bb6\u4fdd\u5b88\u5efa\u8bae\u503c\uff0c\u66f4\u4e25\u4f46\u975e\u56fd\u6807\u5f3a\u5236\uff09\u3002\u5bf9\u5916\u5199\"\u5efa\u8bae\u63a7\u5236\"\uff0c\u4e0d\u5199\"\u5fc5\u987b\"<\/td><td>GB\/T 29044-2012<\/td><\/tr>\n<\/tbody>\n<\/table><br>\n<p class=\"lm-ref\">\u672c\u7ad9\u5730\u6696\u8bbe\u8ba1\u53c2\u6570\u7edf\u4e00\u4ee5\u9f99\u8109\u4f01\u4e1a\u8bbe\u8ba1\u6807\u51c6\u4e3a\u552f\u4e00\u771f\u503c\u6e90\uff1b\u4e0e\u5176\u4ed6\u9875\u9762\u51b2\u7a81\u65f6\u4ee5\u672c\u9875\u4e3a\u51c6\u3002\u5b8c\u6574\u56fd\u6807\u884c\u6807\u7d22\u5f15\u89c1\u300a\u8bbe\u8ba1\u4f9d\u636e\u00b7\u56fd\u6807\u884c\u6807\u300b\u3002<\/p>\n<p data-page-node-id=\"GpL2lbsHQjrZJVQHa42esd\">\u66f4\u5b8c\u6574\u7684\u56fd\u6807\u884c\u6807\u7d22\u5f15\u89c1<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=601\" data-page-node-id=\"lcB51rE53G6THhDtdU1X30\">\u8bbe\u8ba1\u4f9d\u636e \u00b7 \u56fd\u6807\u884c\u6807<\/a>\u3002<\/p>\n\n<h3 data-page-node-id=\"U2JDIsVyojQtFf9zBLeyMK\">5.2\u3000\u70ed\u8d1f\u8377\u8ba1\u7b97\uff1a\u9009\u578b\u7b2c\u4e00\u6b65\uff0c\u4e5f\u662f\u6700\u5e38\u88ab\u8df3\u8fc7\u7684\u4e00\u6b65<\/h3>\n\n<p data-page-node-id=\"GiHNPW6c5wbkgVV6PoGfvX\">\u6309 GB 50736-2012 \u7b2c 5.2.1 \u6761\uff0c\u5fc5\u987b\u5bf9\u6bcf\u4e2a\u623f\u95f4\u8fdb\u884c<strong data-page-node-id=\"kKd98i0JGcyWdv4nF4ZOBG\">\u9010\u9879\u70ed\u8d1f\u8377\u8ba1\u7b97<\/strong>\uff0c\u4e0d\u5f97\u4ee5\u4f30\u7b97\u503c\u66ff\u4ee3\u3002<\/p>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"6bIDadRWEO03NK11PEFjrY\"><table class=\"lm-tb\" data-page-node-id=\"Ok8vCWwsK9uZG6L4aDHgN6\">\n<tbody><tr data-page-node-id=\"ShN05ubjGuh0mz01GLZaG9\"><th style=\"width:30%\" data-page-node-id=\"nkMpkEk47iPJOd6pwWNqCd\">\u5efa\u7b51\u7c7b\u578b<\/th><th style=\"width:26%\" data-page-node-id=\"tLes5EAMGFhEgijtYEL1F6\">\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/th><th data-page-node-id=\"7iwL1Ej7GXABD020Dhz0lv\">\u8bf4\u660e<\/th><\/tr>\n<tr data-page-node-id=\"zJFxRwxrfu8Q2aVOIrDSm9\"><td data-page-node-id=\"E69eDyzqHgzJucqXJreUk3\">\u8282\u80fd\u5efa\u7b51\uff08\u6709\u4fdd\u6e29\uff09<\/td><td data-page-node-id=\"51OrnFYTvG5inGbF1ifCG6\">80\u2013100 W\/\u33a1<\/td><td data-page-node-id=\"1n1BRGc5rFfAEdyg40ndjY\">\u6ee1\u8db3\u6700\u51b7\u5929\u9700\u6c42<\/td><\/tr>\n<tr data-page-node-id=\"gPvVo62jFA1rNqwowDy8vU\"><td data-page-node-id=\"qk4JZVDF2NXKIDD6ls079w\">\u666e\u901a\u5efa\u7b51\uff08\u65e0\u4fdd\u6e29\uff09<\/td><td data-page-node-id=\"AS8ehjVUung3fUjWTu2UNo\">100\u2013120 W\/\u33a1<\/td><td data-page-node-id=\"bnvSyFXqUgIDBZCTmDOker\">\u6ee1\u8db3\u6700\u51b7\u5929\u9700\u6c42<\/td><\/tr>\n<tr data-page-node-id=\"epnVqNmfvKgqLBDhUFNnsS\"><td data-page-node-id=\"Wk5FmRyH1gCUveZ6oMP7gB\">\u843d\u5730\u7a97 \/ \u5927\u9762\u79ef\u73bb\u7483<\/td><td data-page-node-id=\"q2G3dAmtABX1KonjFBxp8C\">120\u2013150 W\/\u33a1<\/td><td data-page-node-id=\"6gytsjLvkhaTs3v6bx0Gnc\">\u9700\u989d\u5916\u8865\u507f<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-tip\" data-page-node-id=\"zjYsuDNCIGaJtpe1yC2UZJ\">\n<strong data-page-node-id=\"FfjakgAuU7IUH0PijKo1YL\">\u9009\u578b\u516c\u5f0f<\/strong>\uff1a\u70ed\u6e90\u529f\u7387(kW) = \u91c7\u6696\u9762\u79ef(\u33a1) \u00d7 \u8bbe\u8ba1\u70ed\u8d1f\u8377(W\/\u33a1) \u00f7 1000 \u00d7 \u5b89\u5168\u7cfb\u6570(1.1\u20131.2)<br data-page-node-id=\"03tn0uBeemjzitOEa4EHLo\">\n<strong data-page-node-id=\"4E4VFnzspKcgdF9s4kYu6y\">\u7b97\u4f8b<\/strong>\uff1a120\u33a1 \u8282\u80fd\u5efa\u7b51 \u2192 120 \u00d7 90 \u00f7 1000 \u00d7 1.15 = 12.4kW \u2192 \u9009 14\u201316kW \u58c1\u6302\u7089\u6216\u5bf9\u5e94\u7a7a\u6c14\u80fd\u4e3b\u673a\u3002<br data-page-node-id=\"Ey9kmWTaqSfGPCQlCvuSVA\">\n\u6ce8\u610f\u533a\u5206\u4e24\u4e2a\u6982\u5ff5\uff1a<strong data-page-node-id=\"gtOwZBXkUK2BnrSDtYVDeD\">\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/strong>\uff08\u7ea6 90W\/\u33a1\uff0c\u7528\u4e8e\u8bbe\u5907\u9009\u578b\uff09\u4e0e<strong data-page-node-id=\"DejXHFEoFCe7SplwaFoRmz\">\u80fd\u8017\u8d1f\u8377<\/strong>\uff08\u7ea6 50W\/\u33a1\uff0c\u6574\u4e2a\u91c7\u6696\u5b63\u5e73\u5747\u503c\uff0c\u7528\u4e8e\u8d39\u7528\u4f30\u7b97\uff09\u3002\n<\/div>\n\n<h3 data-page-node-id=\"k3fBruCNaKK6VySA7wtvfU\">5.3\u3000\u5730\u6696\u8bbe\u8ba1\u6838\u5fc3\u53c2\u6570<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"ooWlrDSzYTqlrEMQlNqyUv\"><table class=\"lm-tb\" data-page-node-id=\"HCZuIASxQOeqnvtQ4L9H2c\">\n<tbody><tr data-page-node-id=\"WV20SVul8S9YeITT0HoQWT\"><th style=\"width:22%\" data-page-node-id=\"qVML7DpOOunsVtqy3FeteL\">\u53c2\u6570<\/th><th style=\"width:22%\" data-page-node-id=\"AVllvnZOCOCQKn3fhFCJ8G\">\u6807\u51c6\u503c<\/th><th style=\"width:28%\" data-page-node-id=\"0syAhvAGGGG5GSdNAvJuYj\">\u8212\u9002\/\u9ad8\u6548\u533a\u95f4<\/th><th data-page-node-id=\"Al4tE4SJcvMLvuULDsNu02\">\u4f9d\u636e<\/th><\/tr>\n<tr data-page-node-id=\"DSc7VgkMDzJKre46px8aDL\"><td data-page-node-id=\"LTld93PMHHx1LG2bmVMQSd\">\u4f9b\u6c34\u6e29\u5ea6<\/td><td data-page-node-id=\"pX8IXGgY8cfFGvHHYqVpRi\">\u226460\u2103<\/td><td data-page-node-id=\"8fdtkLEUX9oIjFpNtCzitm\">35\u201345\u2103\uff08\u4f4e\u6e29\u9ad8\u6548\uff09<\/td><td data-page-node-id=\"ECYjptmEoKY8TOCZcwrXaz\">JGJ 142-2012<\/td><\/tr>\n<tr data-page-node-id=\"2cREO18Jn6iNO9pRAHPRjU\"><td data-page-node-id=\"rWbjdk1XcQO90TP9iFlRDE\">\u4f9b\u56de\u6c34\u6e29\u5dee<\/td><td data-page-node-id=\"lIpHZmq5hGrbLbG7RLLtlr\">5\u201310\u2103<\/td><td data-page-node-id=\"yHiH9S7SrmPeJUS7H7gDIz\">8\u201310\u2103<\/td><td data-page-node-id=\"qc3VlVR2lFj5cMgby8AU88\">\u2014<\/td><\/tr>\n<tr data-page-node-id=\"wxecIUe6HDgrUAc73Tqhdp\"><td data-page-node-id=\"0yaCEdIsK0nxGcJIYSIi9b\">\u5730\u9762\u6e29\u5ea6<\/td><td data-page-node-id=\"MwMu4eIsk0TK50hVvPerjH\">\u226429\u2103\uff08\u957f\u671f\u505c\u7559\u533a\uff09<\/td><td data-page-node-id=\"UeE6D6doCaYu0wkCXvbo1r\">24\u201326\u2103\uff08\u8212\u9002\u533a\u95f4\uff09<\/td><td data-page-node-id=\"KzLjv2wu5rV7zD0LeHjbz5\">JGJ 142-2012 \u7b2c 3.1.3 \u6761<\/td><\/tr>\n<tr data-page-node-id=\"CyG1DPvpnwQAtpXy8i7M44\"><td data-page-node-id=\"Zexuif1dnQ5QqN8QdOg4an\">\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea6<\/td><td data-page-node-id=\"bDY2SrgacXRZDBOwQJqCco\">\u2014<\/td><td data-page-node-id=\"t6hZOodYAUzYk36XcWWOXF\">18\u201322\u2103\uff08\u5367\u5ba4 20\u2103\u3001\u5ba2\u5385 18\u2103\uff09<\/td><td data-page-node-id=\"D5RBwFP7PaS1C9GTbCNKyq\">\u2014<\/td><\/tr>\n<tr data-page-node-id=\"DrDHEhcLPmPvNyyXtdA4Ai\"><td data-page-node-id=\"sVnUkmzuWQhwmOgo9SXNw6\">\u6c34\u6d41\u901f\u5ea6<\/td><td data-page-node-id=\"Ii9WjJ6U7jDZhD4JZRyZtU\">\u22650.25 m\/s\uff08\u6392\u9664\u7a7a\u6c14\uff09<\/td><td data-page-node-id=\"p21IiFiO1wYxg4vZjrT9PV\">0.3\u20130.5 m\/s<\/td><td data-page-node-id=\"i5rwWtyB77ZNRBQrjPnX4s\">\u2014<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<details style=\"background:#f7f9fc;padding:14px;border-radius:10px;margin:16px 0;border:1px solid #e2e8f0;\"><summary style=\"font-weight:bold;cursor:pointer;\">\ud83d\udcce \u9644\u5f55\uff1a\u9f99\u8109\u5730\u6696\u8bbe\u8ba1\u6280\u672f\u57fa\u51c6\uff08\u8bbe\u8ba1\u53e3\u5f84\u3001\u516c\u5f0f\u4e0e\u56de\u8def\u6807\u51c6\uff09<\/summary><div style=\"margin-top:12px;font-size:13px;line-height:1.7;color:#333;\"><p>\u672c\u57fa\u51c6\u4f9d\u636e\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142-2012 \u53ca\u9f99\u8109\u5de5\u7a0b\u5b9e\u8df5\u5236\u5b9a\uff0c\u9002\u7528\u4e8e\u6210\u90fd\u5730\u533a\u58c1\u6302\u7089\uff08\u71c3\u6c14\u70ed\u6e90\uff09\u5e26\u6e7f\u5f0f\u6c34\u5730\u6696\u7684\u8bbe\u8ba1\u4e0e\u6838\u7b97\u3002<\/p><p><strong>\u4e00\u3001\u8bbe\u8ba1\u603b\u5219<\/strong><\/p><table style=\"border-collapse:collapse;width:100%;\"><tbody><tr><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u53c2\u6570<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u6807\u51c6\u503c<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u8bf4\u660e<\/th><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">100 W\/\u33a1\uff08\u91c7\u6696\u9762\u79ef\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u57fa\u7ebf\u53d6\u503c\uff1b\u897f\u6652\u3001\u843d\u5730\u7a97\u3001\u9876\u5c42\u6309\u5de5\u51b5\u4e0a\u6d6e\uff0c\u9010\u95f4\u6838\u7b97<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u8bbe\u8ba1\u5ba4\u6e29<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">20\u2103 \u00b1 2\u2103<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u51ac\u5b63\u91c7\u6696\u8bbe\u8ba1\u6807\u51c6<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u4f9b\u56de\u6c34\u6e29\u5dee<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u0394T = 10\u2103<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u70ed\u6e90\u4fa7\u4e0e\u56de\u8def\u4fa7\u7edf\u4e00\u8bbe\u8ba1\u6e29\u5dee<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u6d41\u91cf\u6362\u7b97<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">1 \u5347\u6c34 \u00b7 1\u2103 = 1 \u5343\u5361<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u6d41\u91cf\u8ba1\u7b97\u7684\u7269\u7406\u57fa\u7840<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u5355\u56de\u8def\u7ba1\u957f<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u2264 100 m\uff08\u56fd\u6807\u4e0a\u9650 120 m\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u4fdd\u8bc1\u5404\u56de\u8def\u6c34\u529b\u5e73\u8861<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u4e3b\u7ba1<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">De32 \u8d77\u6b65<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u58c1\u6302\u7089\u5e26\u5730\u6696\u4e00\u5f8b\u9002\u7528\uff08\u54ea\u6015\u5355\u95f4\u5c0f\u623f\u95f4\uff09\uff1b\u9009\u578b\u6309\u6d41\u91cf\u4e0e\u7ba1\u957f\uff0cDe20 \u4ec5\u7528\u4f5c\u652f\u7ba1<\/td><\/tr><\/tbody><\/table><p><strong>\u4e8c\u3001\u6807\u51c6\u56de\u8def\u6838\u7b97\uff0816 \u7ba1 \/ 20 \u7ba1\uff09<\/strong><\/p><table style=\"border-collapse:collapse;width:100%;\"><tbody><tr><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u7ba1\u5f84<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u56de\u8def\u9762\u79ef<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u56de\u8def\u6d41\u91cf<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u76d8\u7ba1\u95f4\u8ddd<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u56de\u8def\u7ba1\u957f<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u6d41\u901f<\/th><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">16 \u7ba1<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 10 \u33a1\/\u56de\u8def<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 90\u2013100 L\/h<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">125 mm<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">80 m + \u8fde\u63a5\u6bb5 \u2248 100 m<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">0.21\u20130.25 m\/s<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">20 \u7ba1<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 20 \u33a1\/\u56de\u8def<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 172 L\/h<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">200 mm<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u2248 100 m\uff08\u6253\u6ee1\u56fd\u6807\u957f\u5ea6\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 0.24 m\/s<\/td><\/tr><\/tbody><\/table><p>\u6838\u7b97\u65b9\u6cd5\uff1a\u56de\u8def\u70ed\u8d1f\u8377 Q = 100 W\/\u33a1 \u00d7 \u56de\u8def\u9762\u79ef\uff1b\u56de\u8def\u6d41\u91cf G = 0.86 \u00d7 Q \u00f7 10\u2103\uff1b\u56de\u8def\u7ba1\u957f = \u56de\u8def\u9762\u79ef \u00d7 1000 \u00f7 \u95f4\u8ddd + \u8fde\u63a5\u6bb5\uff0c\u5355\u56de\u8def\u4e0d\u8d85\u8fc7 100 m\u3002\u95f4\u8ddd\u5373\u7531\u56de\u8def\u9762\u79ef\u4e0e\u7ba1\u957f\u4e0a\u9650\u53cd\u63a8\u5b9a\u6863\u3002<\/p><p><strong>\u4e09\u3001\u5ba4\u6e29\u8bbe\u8ba1<\/strong>\uff1a\u51ac\u5b63\u91c7\u6696\u8bbe\u8ba1\u5ba4\u6e29 20\u2103 \u00b1 2\u2103\u3002\u8981\u6c42\u5ba4\u6e29\u9ad8\u4e8e\u8bbe\u8ba1\u503c\u65f6\uff0c\u56de\u8def\u6570\u3001\u70ed\u6e90\u529f\u7387\u3001\u4e3b\u7ba1\u6d41\u91cf\u4e09\u9879\u540c\u6b65\u6838\u7b97\u589e\u52a0\uff0c\u4e0d\u5355\u9760\u8c03\u9ad8\u6c34\u6e29\u3002<\/p><p><strong>\u5de5\u7a0b\u8fb9\u754c<\/strong>\uff1a\u5355\u56de\u8def\u9762\u79ef\u4e0a\u9650\u4e0e\u7ba1\u5f84\u7ed1\u5b9a\u2014\u201416 \u7ba1\u5355\u56de\u8def\u7ea6 10 \u33a1 \u5c01\u9876\uff0c20 \u7ba1\u7ea6 20 \u33a1 \u5c01\u9876\uff1b\u623f\u95f4\u9762\u79ef\u8d85\u8fc7\u5355\u56de\u8def\u4e0a\u9650\u65f6\u62c6\u5206\u4e3a\u591a\u4e2a\u56de\u8def\uff0c\u4e0d\u91c7\u7528\u8d85\u51fa\u4e0a\u9650\u7684\u957f\u5355\u56de\u8def\u8bbe\u8ba1\u3002<\/p><p style=\"color:#555;\">\u4f9d\u636e\u51fa\u5904\uff1aJGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b\uff1b\u65e5\u7acb\u6280\u672f\u901a\u77e5 HH-CD-TZ-JS0001\uff08\u4e3b\u7ba1\u6309\u6d41\u91cf\u4e0e\u7ba1\u957f\u9009\u578b\uff09\uff1b\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u6807\u51c6\uff082026-10-16 \u7248\uff09\u3002<\/p><\/div><\/details>\n\n\n<h2 data-page-node-id=\"jKsmh9So381oloPnNLH6Ny\">\u7b2c\u516d\u7ae0\u3000\u65bd\u5de5\u4e0e\u9a8c\u6536\uff1a\u4e09\u5206\u4ea7\u54c1\uff0c\u4e03\u5206\u5b89\u88c5<\/h2>\n\n<h3 data-page-node-id=\"lzbqkPcwfgExNe8ZVNPUDn\">6.1\u3000\u5168\u6d41\u7a0b\u4e94\u4e2a\u9636\u6bb5<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"C8WiF1kyBFNHgyp9I45kPM\"><table class=\"lm-tb\" data-page-node-id=\"GvOS7XoWs83F6UJPnDfPu7\">\n<tbody><tr data-page-node-id=\"Rt0VWxoLGQaOL1DW15eXFB\"><th style=\"width:22%\" data-page-node-id=\"nRBAQaQlvijTMih4J0IWrM\">\u88c5\u4fee\u9636\u6bb5<\/th><th data-page-node-id=\"teH9FJCNbjMfjbOeMEVpIs\">\u5173\u952e\u52a8\u4f5c<\/th><\/tr>\n<tr data-page-node-id=\"1DeajurtTqEHH8Q9l7wQf9\"><td data-page-node-id=\"AF8Geua1El3b9Tw196h9oM\"><strong data-page-node-id=\"qNlDlAiXFRA4APTi5ZJlR7\">\u6c34\u7535\u6539\u9020\u524d<\/strong><\/td><td data-page-node-id=\"DEBImUwzj5mC13cFq6GevA\">\u786e\u5b9a\u5730\u6696\u65b9\u6848\uff08\u70ed\u6e90\u7c7b\u578b\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u3001\u6e29\u63a7\u5668\u5e03\u7ebf\uff09<\/td><\/tr>\n<tr data-page-node-id=\"ayArAC7tfMNezONJ5fU0YF\"><td data-page-node-id=\"4GwMA9VFum6cU3voZCBOuY\"><strong data-page-node-id=\"uSZXZkxBMFAoyv50ooSn7C\">\u6c34\u7535\u6539\u9020\u4e2d<\/strong><\/td><td data-page-node-id=\"IooSRXXyYsKZ7KhLbfck0s\">\u9884\u57cb\u6e29\u63a7\u5668\u4fe1\u53f7\u7ebf\uff08\u8054\u52a8\u63a7\u5236\uff09\u3001\u9884\u7559\u5206\u96c6\u6c34\u5668\u7535\u6e90<\/td><\/tr>\n<tr data-page-node-id=\"oez9tb2CkJ7vvj73E4CTrl\"><td data-page-node-id=\"pqjZrSGTEvllwODWPUMiCe\"><strong data-page-node-id=\"mCbCBB5s8vrn7OjEU1HBRM\">\u5730\u6696\u94fa\u8bbe<\/strong><\/td><td data-page-node-id=\"G88IAhaagBQy0akL2tKdWf\">\u4fdd\u6e29\u677f \u2192 \u53cd\u5c04\u819c \u2192 \u76d8\u7ba1\u94fa\u8bbe\uff08\u95f4\u8ddd\u6309\u8bbe\u8ba1\uff09\u2192 \u6253\u538b\u6d4b\u8bd5 \u2192 \u56de\u586b<\/td><\/tr>\n<tr data-page-node-id=\"7XbqGRH2QQOERRj7Pj14pg\"><td data-page-node-id=\"E6I9DoBbnPlwpHG7CtoITH\"><strong data-page-node-id=\"lTEkwFtdcG9VRz3dwA6aH9\">\u5730\u9762\u627e\u5e73\u524d<\/strong><\/td><td data-page-node-id=\"yHTynYlhaEk8pLG9DxV8BA\">\u786e\u8ba4\u6253\u538b\u5408\u683c\uff08\u4fdd\u538b 24h \u65e0\u538b\u964d\uff09<\/td><\/tr>\n<tr data-page-node-id=\"wbQE6mnrCWiRQyY5N1rbwn\"><td data-page-node-id=\"lopZ37z2ND4uROu17uJrBQ\"><strong data-page-node-id=\"1Cnj43MrvvTPGwGI3klW4I\">\u5730\u9762\u6750\u6599\u5b89\u88c5<\/strong><\/td><td data-page-node-id=\"sFz9BxjOCy9DMJ5ELrZe3v\">\u74f7\u7816\/\u5730\u677f\u94fa\u8bbe\u524d\u518d\u6b21\u786e\u8ba4\u7cfb\u7edf\u538b\u529b<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<h3 data-page-node-id=\"qlfvhI1re8As5Q32dFqF1n\">6.2\u3000\u9a8c\u6536\u7ea2\u7ebf\u6e05\u5355\uff08\u4e1a\u4e3b\u81ea\u67e5\u7528\uff09<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"YAadvd0rAwTeWlICO90KTO\"><table class=\"lm-tb\" data-page-node-id=\"Yx1AqbEHwzxdwQKWrj5tjW\">\n<tbody><tr data-page-node-id=\"B737P2RAgLOAoLzSJoi22G\"><th style=\"width:22%\" data-page-node-id=\"nKCyw4vzFkyWvECM5H6g97\">\u9a8c\u6536\u9879<\/th><th data-page-node-id=\"xk1sEk1WubAHGWKRjf3MZ6\">\u6838\u5fc3\u6307\u6807<\/th><\/tr>\n<tr data-page-node-id=\"VJYrgHcgvudxSpnOy1CDAj\"><td data-page-node-id=\"BjxFRfFhVJ64aenH7q9Ank\"><strong data-page-node-id=\"qclUZgXwNMw3zuozVL2Frr\">\u70ed\u8d1f\u8377\u8ba1\u7b97<\/strong><\/td><td data-page-node-id=\"7SA6SyNqqFHi8IoiYlFkry\">\u670d\u52a1\u5546\u987b\u63d0\u4f9b\u9010\u65f6\u8d1f\u8377\u8ba1\u7b97\u4e66\uff0c\u800c\u4e0d\u662f\"\u9762\u79ef \u00d7 \u6570\u5b57\"\u7684\u7ecf\u9a8c\u4f30\u7b97<\/td><\/tr>\n<tr data-page-node-id=\"0oMKq84nkSn5Mw24lkCKU0\"><td data-page-node-id=\"AgE1wnjxexhsgPimGP9FK0\"><strong data-page-node-id=\"f2t5uEkcgB6Ga5sW0GEzgC\">\u76d8\u7ba1\u95f4\u8ddd\u4e0e\u957f\u5ea6<\/strong><\/td><td data-page-node-id=\"y4wq8o7jyUYQ88HIuFpSKj\">\u6bcf\u56de\u8def\u957f\u5ea6\u4e0d\u8d85\u8fc7 100m\uff0816 \u7ba1\uff09\/ 120m\uff0820 \u7ba1\uff09\uff1b\u95f4\u8ddd\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u786e\u5b9a\uff08\u5e38\u89c4 125\u2013200mm\uff0c\u5916\u5899\u4e0e\u843d\u5730\u7a97\u4fa7\u52a0\u5bc6\uff09<\/td><\/tr>\n<tr data-page-node-id=\"z57soANsVSbSmhkcH1iwCB\"><td data-page-node-id=\"BmZcHY4ZjE9vTZqYTZ6Glo\"><strong data-page-node-id=\"rmzEppKxLa7ZH0bxLC8MT1\">\u5206\u96c6\u6c34\u5668<\/strong><\/td><td data-page-node-id=\"QEJwWQeQSZjeuvAFosgYVd\">\u5fc5\u987b\u4f7f\u7528\u5206\u96c6\u6c34\u5668\uff08\u7ae0\u9c7c\u5f0f\u6216\u540c\u7a0b\u5f0f\uff09\uff0c\u6bcf\u56de\u8def\u72ec\u7acb\u63a7\u5236\uff0c<strong data-page-node-id=\"DkVbb58QtreZD7cKhB7va0\">\u4e25\u7981\u5f02\u7a0b\u7cfb\u7edf<\/strong><\/td><\/tr>\n<tr data-page-node-id=\"eEgFKMMGdD38U75RnEO1R0\"><td data-page-node-id=\"KbSlJhQ16keMBucrihEdnF\"><strong data-page-node-id=\"VneE2GsSVWNwcjCCSTbyfH\">\u6253\u538b\u6d4b\u8bd5<\/strong><\/td><td data-page-node-id=\"8U8j1gTOE7KELEC2kAwWyh\">\u6ce8\u6ee1\u6c34\u540e\u7f13\u6162\u5347\u538b\u81f3 <strong data-page-node-id=\"ke5SMWFWW3u1FByOZRDx0d\">0.6MPa\uff0c\u4fdd\u538b 24 \u5c0f\u65f6\uff0c\u538b\u964d \u22640.05MPa<\/strong> \u4e3a\u5408\u683c\uff1b\u6240\u6709\u63a5\u5934\u9700\u68c0\u6f0f<\/td><\/tr>\n<tr data-page-node-id=\"0hm5G8Bn1A9X1yR8WYvmhY\"><td data-page-node-id=\"nntwnq6vQBnpFDEz0gPd1V\"><strong data-page-node-id=\"t4A6F7CpC4NfFacgKaK2Xv\">\u5404\u56de\u8def\u6e29\u5dee<\/strong><\/td><td data-page-node-id=\"7furREfYKEUvPr0URgLdGQ\">\u8c03\u8bd5\u8fd0\u884c\u540e\uff0c\u5404\u56de\u8def\u56de\u6c34\u6e29\u5dee\u5e94 <strong data-page-node-id=\"EvwTTh7qUtaVODYRZm3rEM\">\u22643\u2103<\/strong>\uff1b\u6e29\u5dee\u8fc7\u5927\u8bf4\u660e\u6c34\u529b\u4e0d\u5e73\u8861\u6216\u56de\u8def\u957f\u5ea6\u5931\u63a7<\/td><\/tr>\n<tr data-page-node-id=\"xEWNFkRo716g7PITGV4nUh\"><td data-page-node-id=\"XIYJ5UaN23TauvTFbNFDNC\"><strong data-page-node-id=\"17TFHNRfwJPq9FzBDeOdcM\">\u4e3b\u7ba1\u7ba1\u5f84<\/strong><\/td><td data-page-node-id=\"RBglXxRTXzabAmZD98nZjv\">\u6309\u9f99\u8109\u6807\u51c6 De32 \u8d77\u6b65\uff0c150\u33a1 \u4ee5\u4e0a\u5fc5\u987b De40\uff1b\u4e3b\u7ba1\u8fc7\u7ec6\u4f1a\u5bfc\u81f4\u6c34\u5faa\u73af\u4e0d\u7545<\/td><\/tr>\n<tr data-page-node-id=\"uGuMvUvr3amonx3C0imbcv\"><td data-page-node-id=\"NwW3wApQdTEWcPfzXMXxmy\"><strong data-page-node-id=\"WWjLxpF7laPre9D8wu3Vgx\">\u6392\u6c14\u9600<\/strong><\/td><td data-page-node-id=\"r4AdiiYAh8e3VhbuW0fUxS\">\u7cfb\u7edf\u6700\u9ad8\u70b9\uff08\u5982\u5206\u6c34\u5668\u9876\u90e8\uff09\u5fc5\u987b\u5b89\u88c5\u81ea\u52a8\u6392\u6c14\u9600<\/td><\/tr>\n<tr data-page-node-id=\"KHQBKz5wI453YEt95aZzdg\"><td data-page-node-id=\"EuO8TkKCx73rniwCdc9Dz1\"><strong data-page-node-id=\"bqVfdwx8US4WiidjUkONVD\">\u56de\u586b\u5c42\u517b\u62a4<\/strong><\/td><td data-page-node-id=\"tlozEINB9jbLOHTkBZavBp\">\u81ea\u7136\u517b\u62a4 7 \u5929\uff0c\u671f\u95f4\u4e25\u7981\u8e29\u8e0f\u4e0e\u5806\u8f7d<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<figure class=\"lm-fig\" data-page-node-id=\"IgtP5ynqHZgbzahcCpwOma\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01-768x1024.jpg\" class=\"lmtall\" alt=\"\u6210\u90fd\u5341\u5e74\u96c5\u5885\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u65bd\u5de5\u5b9e\u62cd\uff0c\u7ba1\u95f4\u8ddd\u6309\u70ed\u8d1f\u8377\u8bbe\u8ba1\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01-768x1024.jpg 768w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"768\" height=\"1024\">\n<figcaption data-page-node-id=\"BogQbp2XpcytUc120ODxwL\">\u5341\u5e74\u96c5\u5885 \u00b7 \u5f20\u8001\u5e08\u5bb6\uff1a\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u73b0\u573a\uff0c\u95f4\u8ddd\u4e25\u683c\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u4e66\u6267\u884c<\/figcaption>\n<\/figure>\n\n<div class=\"lm-warn\" data-page-node-id=\"LHz6NbrW0RWQoz3xV66xYX\">\n<strong data-page-node-id=\"B5Bl2RUbJR4bgrpMUjliwH\">\u53cd\u9762\u6559\u6750<\/strong>\uff1a<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=5092\" data-page-node-id=\"G818Aof92l95KGdPPcbz5m\">\u6210\u90fd\u909b\u5d03\u539f\u5885\u5730\u6696\u65bd\u5de5\u5b9e\u5f55<\/a>\u2014\u2014\n\u65bd\u5de5\u65b9\u6ca1\u6709\u505a\u4fdd\u6e29\u5c42\uff0c\u70ed\u91cf\u5927\u91cf\u5411\u697c\u4e0b\u6563\u5931\uff0c\u4e1a\u4e3b\u540e\u671f\u8fd0\u884c\u8d39\u5c45\u9ad8\u4e0d\u4e0b\uff0c\u6700\u7ec8\u62c6\u9664\u91cd\u505a\u3002\n\u4fdd\u6e29\u677f\u662f\u5730\u6696\u91cc\u6700\u4e0d\u8be5\u7701\u7684\u94b1\u3002\n<\/div>\n\n\n<h2 data-page-node-id=\"WDLz7fWozjgr6KfNiY2vSD\">\u7b2c\u4e03\u7ae0\u3000\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b<\/h2>\n\n<div class=\"lm-case\" data-page-node-id=\"HM04lausgFUaqXf2RyJ9MH\">\n<h4 data-page-node-id=\"8kiRZVsutnoUpPXwQs270o\">\u6848\u4f8b\u4e00\u3000\u4e07\u8001\u5e08\uff1a\u4ece\"\u8bbe\u5907\u5806\u780c\"\u5230\"\u7cfb\u7edf\u8bbe\u8ba1\"\uff08\u522b\u5885\u6539\u9020\uff09<\/h4>\n<p data-page-node-id=\"1MidrOMC07ksHXJ4Y9RfZX\"><strong data-page-node-id=\"qtrgK4gdE0RIlsQwshw2vJ\">\u539f\u6709\u7cfb\u7edf<\/strong>\uff1a\u5927\u91d1\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 + \u5a01\u80fd\u666e\u901a\u7089\u5730\u6696\uff0c\u5e38\u4f4f 6 \u4eba\u3002\n<strong data-page-node-id=\"kUfvzkvGg11mbHdOeeEt4o\">\u4e09\u5927\u75db\u70b9<\/strong>\uff1a\u7a7a\u8c03\u51b7\u98ce\u76f4\u5439\u5e72\u71e5\uff1b\u5730\u6696 80\u33a1 \u6708\u8d39\u7528\u8d85\u8fc7 1000 \u5143\uff1b\u4e24\u7528\u7089\u4f9b\u70ed\u6c34\uff0c\u591a\u70b9\u7528\u6c34\u5ffd\u51b7\u5ffd\u70ed\u3002<\/p>\n<p data-page-node-id=\"AahztsUjeqUv2lzxB3zYF6\"><strong data-page-node-id=\"0PFqeL1BH1GNfBLSoqr2YY\">\u6839\u56e0<\/strong>\uff1a\u5a01\u80fd\u666e\u901a\u7089\uff0824kW \u6216\u66f4\u5927\uff09\u5339\u914d 80\u33a1 \u5730\u6696\uff0c\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u8fdc\u8d85\u9700\u6c42 \u2192 \u5fc5\u7136\u9891\u7e41\u542f\u505c\uff1b\u9505\u7089\u6309\u6c34\u6e29\u5de5\u4f5c\u65e0\u8054\u52a8 \u2192 \u5ba4\u6e29\u8fbe\u6807\u540e\u4ecd\u76f2\u76ee\u70e7\u6c34\uff1b\u4e24\u7528\u7089\u65e2\u91c7\u6696\u53c8\u4f9b\u70ed\u6c34 \u2192 \u4e24\u5934\u90fd\u4e0d\u7a33\u3002<\/p>\n<p data-page-node-id=\"XJNkmibhTUSUr8OAA5LItO\"><strong data-page-node-id=\"qGWjLzdNHQi8e0oVSl9rmN\">\u6539\u9020\u65b9\u6848<\/strong>\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\uff08\u53d8\u9891\u70ed\u6cf5\uff0c\u7cbe\u786e\u5339\u914d\u8d1f\u8377\u3001\u907f\u514d\u542f\u505c\uff09+ \u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1 6 \u53f0 + <strong data-page-node-id=\"0EocH381gND5WZDO7VFr48\">\u72ec\u7acb\u70ed\u6c34\u7cfb\u7edf<\/strong>\uff08\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\uff09\u3002<\/p>\n<p data-page-node-id=\"dn6fgXket0jXS9ePIUGiWE\"><strong data-page-node-id=\"Ce8rJ88EIeSaCshvvWYSw2\">\u542f\u793a<\/strong>\uff1a\u8fd9\u4e00\u6237\u7684\u95ee\u9898\u4e0d\u662f\"\u8bbe\u5907\u4e0d\u591f\u597d\"\uff0c\u800c\u662f<strong data-page-node-id=\"hXYn5pSBOlJjebJRZUmC8M\">\u6ca1\u6709\u4eba\u505a\u7cfb\u7edf\u8bbe\u8ba1<\/strong>\u3002\u6362\u66f4\u8d35\u7684\u9505\u7089\u89e3\u51b3\u4e0d\u4e86\u9891\u7e41\u542f\u505c\uff0c\u6362\u4e2a\u601d\u8def\u505a\"\u5206\u79bb + \u8054\u52a8\"\u624d\u89e3\u51b3\u3002<\/p>\n<\/div>\n\n<div class=\"lm-case\" data-page-node-id=\"ZlxZTGfe60BHRTYnhJ8F6N\">\n<h4 data-page-node-id=\"vVhsNOkShUOfgRo0ca3Ifz\">\u6848\u4f8b\u4e8c\u3000\u5854\u5b50\u5c71\u58f9\u53f7\uff1a\u66fc\u745e\u5fb7\u51b7\u51dd\u7089 + \u8282\u80fd\u8054\u52a8\uff08135\u33a1\uff09<\/h4>\n<p data-page-node-id=\"Sh6hwmMDF2mZBsjpqDx2eL\">135\u33a1 \u91c7\u6696\u9762\u79ef\uff0c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u914d\u5206\u5ba4\u6e29\u63a7\u4e0e\u9505\u7089\u8054\u52a8\u3002\u8fd9\u4e00\u6237\u7684\u4ef7\u503c\u5728\u4e8e\u628a\"20 \u5e74\u66f4\u7701\"\u843d\u5230\u5177\u4f53\u914d\u7f6e\u4e0a\uff1a\u51b7\u51dd\u7089\u5728\u4f4e\u6e29\u5de5\u51b5\uff08\u4f9b\u6c34 35\u201345\u2103\uff09\u4e0b\u624d\u53d1\u6325\u70ed\u6548\u7387\u4f18\u52bf\uff0c\u5fc5\u987b\u914d\u5957\u5206\u5ba4\u6e29\u63a7\u624d\u80fd\u771f\u6b63\u7701\u4e0b\u6765\u3002\n<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=11820\" data-page-node-id=\"DrzcEKSt1bbbmtyxNVgYuV\">\u770b\u5b8c\u6574\u6848\u4f8b<\/a><\/p>\n<\/div>\n\n<div class=\"lm-case\" data-page-node-id=\"BHhbzdubPGIgFzmbBucSak\">\n<h4 data-page-node-id=\"lDKoKPDhkjYpFHhMAgrsxa\">\u6848\u4f8b\u4e09\u3000\u534a\u5c9b\u57ce\u90a6 260\u33a1 \u5927\u5e73\u5c42\uff1a\u5730\u6696 + \u53cc\u70ed\u6e90\u70ed\u6c34<\/h4>\n<p data-page-node-id=\"4VlPZPN5q2SrKKkhLa016r\">260\u33a1 \u5927\u5e73\u5c42\uff0c\u5730\u6696\u7cfb\u7edf\u914d\u53cc\u70ed\u6e90\u70ed\u6c34\u65b9\u6848\uff0c\u89e3\u51b3\u5927\u9762\u79ef\u4f4f\u5b85\u591a\u70b9\u540c\u65f6\u7528\u70ed\u6c34\u7684\u7a33\u5b9a\u6027\u95ee\u9898\u3002\n\u5927\u9762\u79ef\u4f4f\u5b85\u7684\u96be\u70b9\u4e0d\u5728\"\u70ed\u4e0d\u70ed\"\uff0c\u800c\u5728<strong data-page-node-id=\"mXh7d5sXCK91V5SRBYPv5w\">\u6c34\u529b\u5e73\u8861<\/strong>\u2014\u2014\u5fc5\u987b\u7528\u540c\u7a0b\u6216\u7ae0\u9c7c\u5f0f\u3001\u4e3b\u7ba1 De32\uff0c\u5426\u5219\u8fdc\u7aef\u623f\u95f4\u6c38\u8fdc\u4e0d\u70ed\u3002\n<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=7207\" data-page-node-id=\"AHm5nMHocXedFdedttP5AH\">\u770b\u5ba2\u6237\u6863\u6848<\/a>\u3000<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=7219\" data-page-node-id=\"kv0VXsJDtcSEPSt7I2ZNdn\">\u770b\u5b8c\u5de5\u6848\u4f8b<\/a><\/p>\n<\/div>\n\n<div class=\"lm-case\" data-page-node-id=\"DaLY4n3greznrU4WDbgdrh\">\n<h4 data-page-node-id=\"KRnemixqmXHsGJqeLPFrWu\">\u6848\u4f8b\u56db\u3000\u5929\u5e9c\u516c\u56ed\u672a\u6765\u57ce\uff1a\u5c0f\u5361\u51b7\u51dd\u7089\u7684\u5b8c\u6574\u5de5\u827a\u6837\u677f\u548c<\/h4>\n<p data-page-node-id=\"wQXdW7XSVVKJXw2VrIE7V0\">\u8fd9\u4e00\u6237\u628a\u51b7\u51dd\u7089\u8be5\u6709\u7684\u8f85\u4ef6\u505a\u9f50\u4e86\uff1a\u78c1\u6027\u8fc7\u6ee4\u5668\u3001F1 \u4fdd\u62a4\u5242\u3001\u70df\u9053\u4e0e\u6392\u70df\u53e3\u89c4\u8303\u5b89\u88c5\u3001\u5206\u96c6\u6c34\u5668\u4e2d\u592e\u8054\u52a8\u63a7\u5236\u3002\n<strong data-page-node-id=\"3sJNVksB0tiMxQ4iLyw54y\">\u4fdd\u62a4\u5242\u4e0e\u78c1\u6027\u8fc7\u6ee4\u5668\u662f\u51b7\u51dd\u7089\u7cfb\u7edf\u7684\u957f\u5bff\u5173\u952e<\/strong>\u2014\u2014\u80fd\u663e\u8457\u964d\u4f4e\u677f\u6362\u5835\u585e\u4e0e\u6c34\u6cf5\u5361\u6b7b\u7684\u6982\u7387\u3002\n<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=5180\" data-page-node-id=\"yeT8WL6XBAr0aZEMrqAD0p\">\u770b\u5b8c\u6574\u6848\u4f8b<\/a><\/p>\n<\/div>\n\n<div class=\"lm-case\" data-page-node-id=\"m5qTH8Qp07M3Kic9fs1fWX\">\n<h4 data-page-node-id=\"6W7dFyeXn7qDkGwRE9NnZn\">\u6848\u4f8b\u4e94\u3000\u521a\u9700\u6237\u578b\uff1a88\u201399\u33a1 \u4e5f\u80fd\u628a\u5730\u6696\u505a\u5bf9<\/h4>\n<p data-page-node-id=\"IF03ftTjYguI7tnfO4ReZy\">\u5d11\u7389\u9526\u57ce 88\u33a1\u3001\u9f99\u6e56\u6e90\u8457 88\u33a1\u3001\u5929\u5e9c\u58f9\u53f7 99\u33a1 \u4e09\u6237\u540c\u4e3a\u521a\u9700\u6237\u578b\uff0c\u505a\u6cd5\u4e00\u81f4\uff1aDe16 \u76d8\u7ba1 + \u4e3b\u7ba1 De32 \u8d77\u6b65 + \u5206\u5ba4\u6e29\u63a7\u3002\n\u5c0f\u6237\u578b\u7684\u5173\u952e\u4e0d\u662f\"\u5c11\u94fa\u70b9\u7701\u94b1\"\uff0c\u800c\u662f<strong data-page-node-id=\"L5qyRUm2SAw7CX94vZxW2U\">\u70ed\u6e90\u529f\u7387\u5339\u914d<\/strong>\u2014\u2014\u529f\u7387\u9009\u5927\u4e86\u5fc5\u7136\u9891\u7e41\u542f\u505c\uff0c\u53cd\u800c\u66f4\u8d39\u6c14\u3002<\/p>\n<\/div>\n\n<div style=\"margin:18px 0;\" data-page-node-id=\"3SpxbpIWsZQT0kcxNguqCJ\">\n<a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11717\" data-page-node-id=\"l1yN7MlNJOh1mCkcFpIBS8\">\u6210\u90fd\u6b66\u4faf\u533a\u5d11\u7389\u9526\u57ce 88\u33a1 \u5e73\u5c42\uff5c\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03 + \u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n<a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11797\" data-page-node-id=\"VJda5tXfY9yjjUxuDwt4BX\">\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457 88\u33a1 \u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03 + \u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n<a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11817\" data-page-node-id=\"8RmsfYNNFusL1rBfF0Oot8\">\u6210\u90fd\u53cc\u6d41\u533a\u5929\u5e9c\u58f9\u53f7 99\u33a1 \u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u8282\u80fd\u8bbe\u8ba1 + \u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n<a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10632\" data-page-node-id=\"Oi03mdhcctMtOs2k1g8JDD\">\u6210\u90fd\u90eb\u90fd\u533a\u897f\u534e\u82d1 132\u33a1\uff5c\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u516d + \u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u5730\u6696 + \u65b0\u98ce\u4e09\u7cfb\u7edf<\/a>\n<a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11626\" data-page-node-id=\"4xvW6bX6wIn079g94DxiCg\">\u6210\u90fd\u5929\u5e9c\u4e16\u5bb6\u4e8c\u671f\uff5c\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u4e94 + \u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696 + \u65b0\u98ce\u4e09\u7cfb\u7edf\u6848\u4f8b<\/a>\n<a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=6980\" data-page-node-id=\"t6XyuusfMqybHQByqmU3IV\">\u6210\u90fd\u65b0\u90fd\u533a\u4fdd\u5229\u6e56\u5fc3\u5c9b\uff5c\u65e5\u7acb VAM mini \u2161 + \u745e\u7f8e\u53cc\u51b7\u51dd\u7089\u5730\u6696 + \u65b0\u98ce + \u5168\u5c4b\u51c0\u6c34<\/a>\n<\/div>\n\n<p data-page-node-id=\"bY2Co5RdszXVxmlMHH226q\">\u66f4\u591a\u6309\u70ed\u6e90\u54c1\u724c\u3001\u6237\u578b\u9762\u79ef\u5206\u7c7b\u7684\u5b8c\u5de5\u6848\u4f8b\uff0c\u89c1<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" data-page-node-id=\"aEm2trWEkTdqFjpVnzZ2ir\">\u9f99\u8109\u6696\u901a\u6848\u4f8b\u4e2d\u5fc3<\/a>\u4e0e<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" data-page-node-id=\"cddW9mb3aOnKNwotFnGCd6\">\u5730\u6696\u77e5\u8bc6\u5e95\u5ea7<\/a>\u3002<\/p>\n\n<h3 data-page-node-id=\"FzTQktoqDnfO9ZKhkV4JHF\">\u6848\u4f8b\u516d\u3000\u8f9c\u658c\u5bb6\uff1a\u4e00\u6574\u5b63\u6284\u8868\uff0c\u5b9e\u6d4b\u5730\u6696\u70ed\u8d1f\u8377 50\u201360W\/\u33a1<\/h3>\n\n<div class=\"lm-case\" data-page-node-id=\"cSJ0IjRlqvspKZBEELGd3i\">\n<p data-page-node-id=\"GrcaVcr9l7GYiFuyrRDkVX\"><strong data-page-node-id=\"w9s9xgIUl30kmNM6HMi6lk\">\u80cc\u666f<\/strong>\uff1a\u5ba2\u6237\u613f\u610f\u914d\u5408\uff0c\u6574\u4e2a\u91c7\u6696\u5b63\u6301\u7eed\u8bb0\u5f55\u9505\u7089\u8f93\u51fa\u8d1f\u8377\uff0c\u7528\u6765\u9a8c\u8bc1\u5730\u6696\u7684\u771f\u5b9e\u80fd\u8017\u5230\u5e95\u662f\u591a\u5c11\u2014\u2014\n\u800c\u4e0d\u662f\u542c\u62a5\u4ef7\u5355\u4e0a\u90a3\u4e2a\"\u9762\u79ef \u00d7 \u6570\u5b57\"\u3002<\/p>\n<p data-page-node-id=\"qRufdPAAsmZYG9g2ajgfVH\"><strong data-page-node-id=\"R9FgzO8JzDbX0h4MwhLPZK\">\u5b9e\u6d4b\u7ed3\u679c<\/strong>\uff1a\u5730\u6696\u5728\u6574\u4e2a\u91c7\u6696\u5b63\u7684<strong data-page-node-id=\"CzQ1dmWvSB88WVDLn5n8yk\">\u5b9e\u9645\u70ed\u8d1f\u8377\u7ea6 50\u201360W\/\u33a1<\/strong>\uff0c\n\u8fdc\u4f4e\u4e8e\u5f88\u591a\u65b9\u6848\u91cc\u6309 100\u2013120W\/\u33a1 \u7b97\u51fa\u6765\u7684\u6570\u3002<\/p>\n<p data-page-node-id=\"TrAKhYeVnElAAIgIzuCSbr\"><strong data-page-node-id=\"E8IKhEQnk8WRg4LoEoTlsP\">\u7cfb\u7edf\u914d\u7f6e<\/strong>\uff1a\u666e\u901a\u58c1\u6302\u7089\uff08\u70ed\u6548\u7387\u7ea6 90%\uff09+ \u5730\u6696\u7cfb\u7edf\uff0c\u6ca1\u6709\u4e0a\u51b7\u51dd\u7089\uff0c\u4e5f\u6ca1\u6709\u4e0a\u7a7a\u6c14\u80fd\u3002<\/p>\n<div class=\"lm-key\" data-page-node-id=\"URDjHrmB6hLJDFpzqaBswR\">\n<strong data-page-node-id=\"Kw3cAYrnGeadPSDC9NbgRW\">\u8fd9\u7ec4\u6570\u636e\u8bf4\u660e\u4ec0\u4e48<\/strong>\uff1a\n<ul data-page-node-id=\"pvjWgSItmcEA4CAYCXW5kP\">\n<li data-page-node-id=\"hDk3rvAOtGKVxQ8A5sADyK\"><strong data-page-node-id=\"TlJ1J07W2i03yb4KqVFk8D\">\u8bbe\u8ba1\u8d1f\u8377\uff08100\u2013120W\/\u33a1\uff09\u662f\u7528\u6765\u9009\u8bbe\u5907\u7684<\/strong>\uff0c\u5bf9\u5e94\"\u4e00\u5e74\u91cc\u6700\u51b7\u7684\u90a3\u51e0\u5929\"\uff1b<\/li>\n<li data-page-node-id=\"5FikHDXWbfIKFfJAJU7EJj\"><strong data-page-node-id=\"wEgfDsS1apkla57rydHBz8\">\u80fd\u8017\u8d1f\u8377\uff08\u5b9e\u6d4b 50\u201360W\/\u33a1\uff09\u662f\u7528\u6765\u7b97\u8d39\u7528\u7684<\/strong>\uff0c\u5bf9\u5e94\"\u6574\u4e2a\u51ac\u5929\u7684\u5e73\u5747\u503c\"\uff1b<\/li>\n<li data-page-node-id=\"ikTHQe03dKzaPySuLk6jLr\">\u62ff\u8bbe\u8ba1\u8d1f\u8377\u53bb\u4f30\u7b97\u8fd0\u884c\u8d39\uff0c\u4e00\u5b9a\u4f1a\u88ab\u5413\u5230\uff1b\u62ff\u80fd\u8017\u8d1f\u8377\u53bb\u9009\u8bbe\u5907\uff0c\u6700\u51b7\u5929\u4e00\u5b9a\u4e0d\u591f\u70ed\u3002<\/li>\n<\/ul>\n\u5728\u7cfb\u7edf\u8bbe\u8ba1\u5408\u7406\u3001\u4f7f\u7528\u4e60\u60ef\u6b63\u5e38\u7684\u524d\u63d0\u4e0b\uff0c50\u201360W\/\u33a1 \u662f\u6210\u90fd\u5730\u6696\u4e00\u4e2a<strong data-page-node-id=\"dqmRm0izJz1CI9v8lMlGgL\">\u53ef\u4ee5\u5b9e\u6d4b\u590d\u73b0<\/strong>\u7684\u8282\u80fd\u533a\u95f4\u3002\n<\/div>\n<\/div>\n\n\n<h2 data-page-node-id=\"buA00MgEil0X5vRo1aMnsw\">\u7b2c\u516b\u7ae0\u3000\u6210\u90fd\u5730\u6696\u4ef7\u683c\u53c2\u8003<\/h2>\n\n<p data-page-node-id=\"LM6iLRN8g8VdxQTK9U7YuF\">\u5730\u6696\u662f<strong data-page-node-id=\"UQF9GIIORxjCystciLRsja\">\u6309\u5b9e\u9645\u94fa\u8bbe\u9762\u79ef\u7ed3\u7b97<\/strong>\u7684\u7cfb\u7edf\uff08\u4e0d\u662f\u5efa\u7b51\u9762\u79ef\u4e5f\u4e0d\u662f\u5957\u5185\u9762\u79ef\uff1b\u5ba2\u5385\/\u9910\u5385\/\u5367\u5ba4\u94fa\u8bbe\uff0c\u53a8\u536b\u4e00\u822c\u4e0d\u542b\uff0c\u9ed8\u8ba4\u53c2\u8003 66\u33a1\uff09\u3002\u4ee5\u4e0b\u4e3a\u9f99\u8109\u5b98\u7f51<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10977\" data-page-node-id=\"Idqjwz13t8v65ubH9bKpQB\">\u6210\u90fd\u5730\u6696\u4ef7\u683c\u53c2\u8003<\/a>\u7684\u771f\u5b9e\u5957\u9910\u5355\u4ef7\uff1a<\/p>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"Rl7EyHnvGjKSyW8hvXWhpN\"><table class=\"lm-tb\" data-page-node-id=\"S55xuD3u6iEhHBGoKELkMt\">\n<tbody><tr data-page-node-id=\"ENRCr1jBP0GvRzERGYkR3L\"><th style=\"width:16%\" data-page-node-id=\"phvI3NO2vVLfl1QZQxLKKT\">\u623f\u5c4b\u5de5\u51b5<\/th><th style=\"width:18%\" data-page-node-id=\"6KLnqlgluCnCDZIg7WWLcA\">\u63a8\u8350\u5957\u9910<\/th><th style=\"width:15%\" data-page-node-id=\"nAYij5ZC8tDvQRlRNCQKVy\">\u53c2\u8003\u5355\u4ef7<\/th><th data-page-node-id=\"NlvUU3ZlJn5bDBCSLrZFFu\">\u57fa\u7840\u914d\u7f6e\u524d\u63d0<\/th><\/tr>\n<tr data-page-node-id=\"p44daEbg5i6AYus6NDAU8E\"><td data-page-node-id=\"C3a2XtvGacoSRnUjUC1Xsm\">\u6e05\u6c34\u623f\uff08\u6bdb\u576f\uff09<\/td><td data-page-node-id=\"viUzbXFCHpyXGnotBkBlAM\">\u4f1f\u661f\u6807\u51c6\u5305\uff08\u603b\u63a7\uff09<\/td><td data-page-node-id=\"FIqZ9lOD2ZGMf08RVDzvI1\"><strong data-page-node-id=\"Yf1EEQB0Fve3MOtnAfwxxw\">99 \u5143\/\u33a1<\/strong><\/td><td data-page-node-id=\"0ZxAG5hxueYbhlaTm5wo08\">\u4f1f\u661f 16 \u7ba1\u3001\u95f4\u8ddd 125mm\uff08\u7ea6 10\u33a1\/\u56de\u8def\uff09\uff0c\u8bfa\u5c14\u6324\u5851\u677f 2cm\uff0c\u542b\u603b\u63a7\uff1b\u4e0d\u542b\u5206\u5ba4\u6e29\u63a7\u3001\u4e0d\u542b\u767d\u6676\u677f\u5347\u7ea7<\/td><\/tr>\n<tr data-page-node-id=\"HIVnLVn7JzsS3OXIJ3QnXi\"><td data-page-node-id=\"fojjSWmMI9zfOWU79izqky\">\u6e05\u6c34\u623f\uff08\u6bdb\u576f\uff09<\/td><td data-page-node-id=\"cHDbEPkbxZ1IzAOPxeDXCA\">\u8282\u80fd\u5305<\/td><td data-page-node-id=\"HVZRVO9rR9prmmsjtyASN9\"><strong data-page-node-id=\"dkg1bGVdnpD4wBz5t7sVdP\">169 \u5143\/\u33a1<\/strong><\/td><td data-page-node-id=\"es5omEsVjS2TSIrPiTpD8V\">\u4f1f\u661f\u767d\u6676\u677f 3cm\uff0c\u66fc\u745e\u5fb7\u5206\u5ba4\u6e29\u63a7 + \u9505\u7089\u8054\u52a8\uff0c\u8d60\u4f1f\u661f\u963b\u6c27\u7ba1<\/td><\/tr>\n<tr data-page-node-id=\"0ymsxCa9KzZ7S9tYN6B6Jv\"><td data-page-node-id=\"NTGq9StKwVyu3RsRkamXHc\">\u7cbe\u88c5\u623f\u6539\u9020<\/td><td data-page-node-id=\"KVn6lRpgjnjbGeDgdMVOYD\">\u4f1f\u661f\u6807\u51c6\u5305\uff08\u5206\u63a7\uff09<\/td><td data-page-node-id=\"YrAStiFZzC1FdeJqFdkIAx\"><strong data-page-node-id=\"SCKBeyp1AInyMaGk37VOni\">119 \u5143\/\u33a1<\/strong><\/td><td data-page-node-id=\"yWLCpQavcQ8ix7prUpThlm\">\u4f1f\u661f 16 \u7ba1\u3001\u95f4\u8ddd 125mm\uff08\u7ea6 10\u33a1\/\u56de\u8def\uff09\uff0c\u8bfa\u5c14\u6324\u5851\u677f 2cm\uff0c\u542b\u5206\u5ba4\u6e29\u63a7\uff08\u7cbe\u88c5\u6309\u623f\u95f4\u72ec\u7acb\u63a7\u6e29\uff09<\/td><\/tr>\n<tr data-page-node-id=\"P5tO5VlABIXH6Wvb7gYq6b\"><td data-page-node-id=\"X2DdQLHlRCTmCgkAftS4Mj\">\u7cbe\u88c5\u623f\u6539\u9020<\/td><td data-page-node-id=\"YRmMZFu9IXjuaLtdR6R4n8\">\u8282\u80fd\u5305<\/td><td data-page-node-id=\"u4pLaFLKAh7oGIfXIsyM8D\"><strong data-page-node-id=\"mTbRBBJOWHjEYcQOOIXoo6\">169 \u5143\/\u33a1<\/strong><\/td><td data-page-node-id=\"do5pmPFUbvwhXFiV2Q4oFj\">\u540c\u8282\u80fd\u5305\u914d\u7f6e\uff0c\u53e6\u542b\u57fa\u7840\u6210\u54c1\u4fdd\u62a4\u4e0e\u62c6\u6539\u5904\u7406<\/td><\/tr>\n<tr data-page-node-id=\"nO5gsdGGUKk9wfPqLFo8Jf\"><td data-page-node-id=\"5T0xxfXgWNPEktOgXGbIqa\">\u4efb\u610f\u5de5\u51b5\u5347\u7ea7<\/td><td data-page-node-id=\"HlcyL1WSNnFcSmsMANFjv0\">\u767d\u6676\u677f\u5347\u7ea7<\/td><td data-page-node-id=\"XkvXCbso6VG6o0X4e4cR7m\"><strong data-page-node-id=\"IUHRfTz9adXjyeXhLneHvq\">+15 \u5143\/\u33a1<\/strong><\/td><td data-page-node-id=\"pCcZnbB7ssVb0rrC0cXoRA\">\u4f1f\u661f\u767d\u6676\u677f\u66ff\u6362\u8bfa\u5c14\u6324\u5851\u677f\uff0c\u66f4\u8584\u66f4\u6297\u538b<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<div class=\"lm-tip\" data-page-node-id=\"5cPtmJzrpsQuA7Pl158Hcs\">\n<strong data-page-node-id=\"hVPOEuUulYyOhG46OKOCOV\">\u4ee5 66\u33a1 \u5730\u6696\u9762\u79ef\u4f30\u7b97<\/strong>\uff08\u4e0d\u542b\u9505\u7089\u4e3b\u673a\uff09\uff1a\u6e05\u6c34\u6807\u51c6\u5305 99 \u5143\/\u33a1 \u2248 <strong data-page-node-id=\"iFw5okMWs6etpKbhAMtqTK\">6,534 \u5143<\/strong>\uff1b\u8282\u80fd\u5305 169 \u5143\/\u33a1 \u2248 <strong data-page-node-id=\"unJY3dT3DGBnOtXkOx4aCX\">11,154 \u5143<\/strong>\u3002\n\u9762\u79ef\u8d8a\u5c0f\u5355\u65b9\u7565\u9ad8\uff08\u5206\u96c6\u6c34\u5668\u3001\u4e3b\u63a7\u7b49\u56fa\u5b9a\u6210\u672c\u644a\u8584\uff09\uff0c\u5c5e\u6b63\u5e38\u73b0\u8c61\u3002\n\u9505\u7089\u4e3b\u673a\u8d39\u7528\u53e6\u8ba1\uff0c\u53c2\u8003<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=11082\" data-page-node-id=\"G8qOaeRj0XRNSH9jYTC7uN\">\u6210\u90fd\u58c1\u6302\u7089\u4ef7\u683c<\/a>\u4e0e<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=11074\" data-page-node-id=\"DO9DD0cFqde7TGDnHpJq1s\">\u51b7\u51dd\u7089\u600e\u4e48\u9009<\/a>\uff1b\n\u60f3\u4e00\u6b21\u914d\u9f50\"\u7a7a\u8c03 + \u5730\u6696\u8054\u52a8\"\uff0c\u770b<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10975\" data-page-node-id=\"f7HL1etjPiuHKk0YJs0TUD\">\u6210\u90fd\u65e5\u7acb\u4e24\u8054\u4f9b\u4ef7\u683c<\/a>\u3002\n<\/div>\n\n<p data-page-node-id=\"0af02rj5NSouUyP1AFYH0p\"><strong data-page-node-id=\"IfBBgPpsqZah2GAuzE8HSn\">\u62c9\u9ad8\u6216\u964d\u4f4e\u6700\u7ec8\u62a5\u4ef7\u7684\u516d\u4e2a\u56e0\u7d20<\/strong>\uff1a\u2460\u623f\u5c4b\u5de5\u51b5\uff08\u6e05\u6c34 vs \u7cbe\u88c5\u62c6\u6539\uff09\u2461\u94fa\u8bbe\u9762\u79ef \u2462\u4fdd\u6e29\u5c42\u9009\u578b \u2463\u63a7\u5236\u65b9\u5f0f\uff08\u603b\u63a7 vs \u5206\u63a7\uff09\u2464\u9505\u7089\u4e3b\u673a\u662f\u5426\u542b\u5165 \u2465\u8f85\u6750\u4e0e\u65bd\u5de5\u96be\u5ea6\uff08\u963b\u6c27\u7ba1\u3001\u66fc\u745e\u5fb7\u5206\u96c6\u6c34\u5668\u3001\u9ad8\u5c42\u540a\u88c5\u7b49\uff09\u3002<\/p>\n\n<p data-page-node-id=\"9A0xu7zNJogjcOwa1u7fxE\">\u60f3\u5148\u81ea\u5df1\u7b97\u4e00\u7248\uff0c\u76f4\u63a5\u7528<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\" data-page-node-id=\"E3VsvlSUVMU7Ld2SD8J1t4\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/a>\uff08\u56de\u586b\u3001\u4fdd\u6e29\u3001\u7ba1\u9053\u3001\u65bd\u5de5\u3001\u5206\u63a7\u9010\u9879\u6d4b\u7b97\uff09\u3002<\/p>\n\n<h2 data-page-node-id=\"1m92bWuHy5v15H5fJFj2P6\">\u7b2c\u4e5d\u7ae0\u3000\u7ef4\u62a4\u4e0e\u4fdd\u517b<\/h2>\n\n<h3 data-page-node-id=\"qJrLQ8kSgoIBB4uyNdF8BI\">9.1\u3000\u7ef4\u62a4\u5468\u671f\uff1a\u4ec0\u4e48\u65f6\u5019\u8be5\u505a\u4ec0\u4e48<\/h3>\n\n<div class=\"lm-tb-wrap\" data-page-node-id=\"Mm7MpYDxJjWn4OA8NQRXfd\"><table class=\"lm-tb\" data-page-node-id=\"JRzqjaLgrd2oZx3Blojqi2\">\n<tbody><tr data-page-node-id=\"Dz61ZaUT1ezOyv3byGkbya\"><th style=\"width:26%\" data-page-node-id=\"g4S0oRYmItDj96GGBHssmk\">\u7ef4\u62a4\u9879\u76ee<\/th><th style=\"width:26%\" data-page-node-id=\"rMPvNN311QvS3TEAtGyrf7\">\u5468\u671f<\/th><th data-page-node-id=\"CBwF7NbsSIugoxIqhujJcw\">\u8bf4\u660e<\/th><\/tr>\n<tr data-page-node-id=\"MCE7OZk7nLfCLFh6cjEzfo\"><td data-page-node-id=\"Et72wUU2fFPVZAGMUA0G99\">\u5206\u96c6\u6c34\u5668\u6392\u6c14<\/td><td data-page-node-id=\"gJHUI6pSC7MFvBkvoYFUw4\">\u6bcf\u5e74\u91c7\u6696\u5b63\u524d<\/td><td data-page-node-id=\"xCEV6PF7aVHVzOCzFcvdjU\">\u6c14\u5835\u662f\"\u67d0\u4e00\u8def\u4e0d\u70ed\"\u6700\u5e38\u89c1\u7684\u539f\u56e0<\/td><\/tr>\n<tr data-page-node-id=\"T8HXzutk127UvFXimtvNHF\"><td data-page-node-id=\"a9dOQcg6lXFfxaH8WdwCrK\">\u78c1\u6027\u8fc7\u6ee4\u5668\u6e05\u6d17<\/td><td data-page-node-id=\"QZ4Fnl1JhmmVMJxKnhKcoM\">\u6bcf\u5e74<\/td><td data-page-node-id=\"ca2iUuhyE8cwEECAALv3n4\">\u7cfb\u7edf\u6c34\u53d1\u9ed1\u5c31\u662f\u6742\u8d28\u8fc7\u591a\u7684\u4fe1\u53f7<\/td><\/tr>\n<tr data-page-node-id=\"2VBDPFnRRV44IccDUEtNbo\"><td data-page-node-id=\"TnYuXbjTE0pth6kKnjaueX\">\u7cfb\u7edf\u538b\u529b\u68c0\u67e5<\/td><td data-page-node-id=\"i3BpRlGc404qXhZfRwKB9J\">\u6bcf\u5e74\u91c7\u6696\u5b63\u524d<\/td><td data-page-node-id=\"7lsB4yyS0Hcc6z6AiapxQJ\">\u51b7\u6001\u5e94\u4fdd\u6301\u5728 1\u20132bar<\/td><\/tr>\n<tr data-page-node-id=\"xLSLX3MaeTxuEbzq2O1cvM\"><td data-page-node-id=\"U8JDDFuZmcfoEY5ByKHzlU\"><strong data-page-node-id=\"r3SihP5VH6v5gNiLpaZmVL\">\u5730\u6696\u7ba1\u8def\u6e05\u6d17<\/strong><\/td><td data-page-node-id=\"9RfqmD8OqsG1FyME1PhI4Z\"><strong data-page-node-id=\"3urpdMxJi2kYiO2IDOUuR5\">\u6bcf 3\u20135 \u5e74<\/strong><\/td><td data-page-node-id=\"X5xEg9lhuCnux6qFeOSdsp\">\u6c34\u8d28\u5dee\u6216\u7cfb\u7edf\u6c34\u5448\u94c1\u9508\u8272\u65f6\u5e94\u63d0\u524d<\/td><\/tr>\n<tr data-page-node-id=\"8khLw4Zx2MDdBF1dfcoyHc\"><td data-page-node-id=\"dlLIDqYcIszoH9zror2Os3\"><strong data-page-node-id=\"RHG4SABnDbAL1msRf44NhG\">\u58c1\u6302\u7089\u4e13\u4e1a\u4fdd\u517b<\/strong><\/td><td data-page-node-id=\"d9vV5xUXFlUBPr9fCCD9AJ\"><strong data-page-node-id=\"lBDqhV6qBEbKwI56bNXUpE\">\u51fa\u6c34\u6e29\u5ea6 &lt;55\u2103\uff1a\u6bcf\u5e74<\/strong><br data-page-node-id=\"HsoAd5PiQo7DTT9h2VeYRf\"><strong data-page-node-id=\"zFtPebEqBrlqiHnSVoQMuz\">\u51fa\u6c34\u6e29\u5ea6 \u226555\u2103\uff1a\u6bcf 2 \u5e74<\/strong><\/td><td data-page-node-id=\"oj3Aog2Xu0pMvc8MdBG4os\">\u6e05\u7406\u71c3\u70e7\u5668\u3001\u68c0\u67e5\u70df\u9053\u3001\u68c0\u6d4b\u71c3\u6c14\u538b\u529b<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<p data-page-node-id=\"HC82oQUAeS3V9JIEsFFNdu\"><strong data-page-node-id=\"9m6VPsNvdb7Zuk2K9mqj08\">\u590f\u5b63\u4e0d\u8981\u6392\u7a7a\u7cfb\u7edf\u6c34<\/strong>\uff0c\u5e94\u6ee1\u6c34\u4fdd\u517b\u2014\u2014\u6392\u7a7a\u4f1a\u8ba9\u7a7a\u6c14\u8fdb\u5165\u7ba1\u9053\uff0c\u52a0\u901f\u5185\u58c1\u6c27\u5316\u3002\n\u4f7f\u7528\u963b\u6c27\u7ba1\u80fd\u663e\u8457\u5ef6\u7f13\u7ba1\u9053\u7ed3\u57a2\uff0c\u5f53\u521d\u591a\u82b1\u7684\u90a3\u70b9\u5dee\u4ef7\uff0c\u51e0\u5e74\u540e\u53ef\u80fd\u5c31\u662f\u7701\u4e0b\u7684\u4e00\u7b14\u6e05\u6d17\u8d39\u3002<\/p>\n\n<h3 data-page-node-id=\"e9ieEjKZKqcj1zrpbEtleQ\">9.2\u3000\u56db\u5b63\u4f7f\u7528\u6307\u5357<\/h3>\n<ul data-page-node-id=\"7CXUnUgLYGZMXN2d2bp1pX\">\n<li data-page-node-id=\"6A3B6l87tKU7XFqIKRkYdK\"><strong data-page-node-id=\"D4ljd1cSmuJueGdNDruwzH\">\u9996\u6b21\u5f00\u542f<\/strong>\uff1a\u4f9b\u6c34\u6e29\u5ea6\u9636\u68af\u5f0f\u5347\u6e29\uff0c\u6bcf\u5929\u5347 5\u2103 \u5de6\u53f3\uff0c\u907f\u514d\u56de\u586b\u5c42\u9aa4\u70ed\u5f00\u88c2<\/li>\n<li data-page-node-id=\"ekkvkie4OsgO2LzygSn8Eq\"><strong data-page-node-id=\"Cd2jvRdALmcDmoF6aafuzd\">\u767d\u5929\u4e0a\u73ed \/ \u77ed\u65f6\u79bb\u5bb6<\/strong>\uff1a\u4e0d\u8981\u628a\u5730\u6696\u5173\u6389\uff0c\u6b63\u786e\u505a\u6cd5\u662f\u8bbe<strong data-page-node-id=\"SAptu7yMY7FaS9xF08NPX4\">\u4f4e\u6e29\u8fd0\u884c 15\u2103<\/strong>\u3002\u5730\u6696\u56de\u586b\u5c42\u84c4\u70ed\u91cf\u5927\uff0c\u4ece 15\u2103 \u56de\u5230 20\u2103 \u8981\u597d\u51e0\u4e2a\u5c0f\u65f6\uff1b\u5982\u679c\u6bcf\u5929\u65e9\u4e0a\u5173\u673a\u3001\u665a\u4e0a\u56de\u5bb6\u518d\u5f00\uff0c\u9505\u7089\u8981\u7528\u6700\u5927\u529f\u7387\u731b\u70e7\uff0c\u53cd\u800c\u6bd4\u5168\u5929\u4f4e\u6e29\u7ef4\u6301<strong data-page-node-id=\"YDvXsUYoCxA4bHjIbqF7x1\">\u66f4\u8d39\u6c14<\/strong>\u3002\u5224\u65ad\u6807\u51c6\uff1a\u79bb\u5bb6\u8d85\u8fc7 3 \u5929\u518d\u8003\u8651\u5173\uff0c3 \u5929\u4ee5\u5185\u4e00\u5f8b\u4f4e\u6e29\u8fd0\u884c<\/li>\n<li data-page-node-id=\"imF4gIKVP1fDjDX82bjaiV\"><strong data-page-node-id=\"1y5A2aNqReJTod3qOb09W4\">\u51ac\u5b63\u957f\u671f\u5916\u51fa<\/strong>\uff1a\u4e0d\u8981\u5b8c\u5168\u5173\u95ed\uff0c\u8bbe\u7f6e\u9632\u51bb\u6a21\u5f0f\uff088\u201312\u2103\uff09\uff0c\u9632\u6b62\u7ba1\u9053\u51bb\u88c2<\/li>\n<li data-page-node-id=\"IDJvua3UaeLOa7NE2CbKqi\"><strong data-page-node-id=\"5uuDadZhv8JLfpCFaABahM\">\u590f\u5b63<\/strong>\uff1a\u6ee1\u6c34\u4fdd\u517b\uff0c\u4e0d\u8981\u6392\u7a7a\u7cfb\u7edf\u6c34\uff08\u6392\u7a7a\u4f1a\u52a0\u901f\u7ba1\u9053\u6c27\u5316\uff09<\/li>\n<\/ul>\n\n<p data-page-node-id=\"0GnqjInbV0IzBHJQpAUNdp\">\u9f99\u8109\u7684\u4f1a\u5458\u5236\u670d\u52a1\u5305\u542b\u5efa\u6863\u3001\u5e74\u5ea6\u56de\u8bbf\u4e0e 10 \u5e74\u80fd\u8017\u8ddf\u8e2a\uff0c\u8be6\u89c1<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" data-page-node-id=\"FcyRwBMWVRXP4jgKCZAlAE\">\u670d\u52a1\u4fdd\u969c<\/a>\u3002\n\u9505\u7089\u62a5\u9519\u7c7b\u95ee\u9898\u7684\u771f\u5b9e\u6392\u67e5\u8fc7\u7a0b\u89c1<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=12256\" data-page-node-id=\"jkqPioUO4ItwGAlhWkTXS3\">\u535a\u4e16\u9505\u7089\u62a5\u9519 EA \u6392\u67e5\u5b9e\u5f55<\/a>\u4e0e<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=11337\" data-page-node-id=\"BI1rKRpwusJTAk7t8zMEfN\">\u83f2\u65af\u66fc\u9505\u7089\u8c03\u8bd5\u5b9e\u5f55<\/a>\u3002<\/p>\n\n<h2 data-page-node-id=\"jgP7Uf73vPSqNmmQBfRuM7\">\u7b2c\u5341\u7ae0\u3000\u5e38\u89c1\u95ee\u9898\uff08\u6210\u90fd\u672c\u5730\u7248\uff09<\/h2>\n\n<div class=\"lm-faq\" data-page-node-id=\"ZxVv1CZDegiMZVjwLUVTSA\"><p class=\"q\" data-page-node-id=\"ZnoinYoBZudHHmyNvtAC36\">1. \u6210\u90fd\u5730\u6696\u591a\u5c11\u94b1\u4e00\u5e73\u7c73\uff1f66\u33a1 \u5927\u6982\u8981\u82b1\u591a\u5c11\uff1f<\/p><p class=\"a\" data-page-node-id=\"U4whbSYOUyj1JDJwrTODuw\">\u6309\u5b9e\u9645\u94fa\u8bbe\u9762\u79ef\u7ed3\u7b97\uff0c\u9f99\u8109\u53c2\u8003\u5355\u4ef7\u4e3a\uff1a\u6e05\u6c34\u623f\u6807\u51c6\u5305 99 \u5143\/\u33a1\uff08\u603b\u63a7\uff09\u3001\u7cbe\u88c5\u6539\u9020 119 \u5143\/\u33a1\uff08\u5206\u63a7\uff09\u3001\u8282\u80fd\u5305 169 \u5143\/\u33a1\uff0c\u767d\u6676\u677f\u5347\u7ea7 +15 \u5143\/\u33a1\u3002\u4ee5 66\u33a1 \u8ba1\uff0c\u6807\u51c6\u5305\u7ea6 6,534 \u5143\u3001\u8282\u80fd\u5305\u7ea6 11,154 \u5143\uff0c<strong data-page-node-id=\"08CkCvHfPnPCJGnEhZwJDo\">\u5747\u4e0d\u542b\u9505\u7089\u4e3b\u673a<\/strong>\u3002\u9762\u79ef\u8d8a\u5c0f\u5355\u65b9\u7565\u9ad8\uff0c\u5c5e\u6b63\u5e38\u3002\u8be6\u7ec6\u53e3\u5f84\u89c1<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10977\" data-page-node-id=\"jXJlSBizrzkNPVzLScULof\">\u6210\u90fd\u5730\u6696\u4ef7\u683c\u53c2\u8003<\/a>\uff0c\u4e5f\u53ef\u4ee5\u5148\u7528<a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\" data-page-node-id=\"KNeweMyVCoxFFiDdEX9pwy\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/a>\u81ea\u5df1\u7b97\u4e00\u7248\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"XQx5TtFrnwLvTh3T8XKzHD\"><p class=\"q\" data-page-node-id=\"J6Sr0wwEneF1Bb6VvgThCd\">2. \u71c3\u6c14\u58c1\u6302\u7089\u3001\u7a7a\u6c14\u80fd\u3001\u7535\u5730\u6696\uff0c\u6210\u90fd\u5bb6\u5ead\u600e\u4e48\u9009\uff1f<\/p><p class=\"a\" data-page-node-id=\"oZlX64K4ceAuIJ1740v15e\">\u6709\u5929\u7136\u6c14\u3001\u8ffd\u6c42\u4f4e\u521d\u88c5\u548c\u7a33\u5b9a\u7684\u8212\u9002\u5ea6\u7684\uff0c\u9009\u51b7\u51dd\u7089\uff1b\u957f\u671f\u81ea\u4f4f\u3001\u8ffd\u6c42 20 \u5e74\u603b\u6295\u5165\u6700\u4f4e\u7684\uff0c\u9009\u7a7a\u6c14\u80fd\uff0820 \u5e74\u7ea6 6.0 \u4e07\uff0c\u6bd4\u666e\u901a\u7089\u7701\u7ea6 3.5 \u4e07\uff09\uff1b\u53ea\u5728\u536b\u751f\u95f4\u7b49 5\u201350\u33a1 \u5c40\u90e8\u8865\u5145\u91c7\u6696\u7684\uff0c\u9009\u7535\u5730\u6696\u3002\u7a7a\u6c14\u80fd\u9002\u5408 100\u33a1 \u4ee5\u4e0a\uff0c\u56e0\u4e3a\u8bbe\u5907\u6210\u672c\u8981\u644a\u8584\u624d\u5212\u7b97\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"c0eiHM14eGtl2X8WAzHGmI\"><p class=\"q\" data-page-node-id=\"ej3F75ch1g2DKZGiCG7OCD\">3. \u51b7\u51dd\u7089\u4e00\u5b9a\u6bd4\u666e\u901a\u7089\u7701\u6c14\u5417\uff1f<\/p><p class=\"a\" data-page-node-id=\"0XIeF4bNjCLsAblaH1X4ny\">\u4e0d\u4e00\u5b9a\uff0c<strong data-page-node-id=\"dPueXFWC1iizuApBwBgqUQ\">\u6709\u524d\u63d0<\/strong>\u3002\u51b7\u51dd\u7089\u5fc5\u987b\u5728\u4f4e\u6e29\u7cfb\u7edf\uff08\u4f9b\u6c34\u6e29\u5ea6 \u226455\u2103\uff09\u4e0b\u624d\u80fd\u53d1\u6325\u70ed\u6548\u7387\u4f18\u52bf\uff0c\u6240\u4ee5\u5b83\u5929\u7136\u9002\u914d\u5730\u6696\u3002\u5982\u679c\u914d\u5957\u7684\u662f\u4f20\u7edf\u9ad8\u6e29\u6696\u6c14\u7247\uff0c\u51b7\u51dd\u7089\u7684\u8282\u80fd\u4f18\u52bf\u65e0\u6cd5\u4f53\u73b0\uff0c\u7b49\u4e8e\u767d\u82b1\u94b1\u3002\u540c\u65f6\u51b7\u51dd\u7089\u5fc5\u987b\u914d\u5ba4\u5916\u6e29\u5ea6\u8865\u507f\u6216\u6c14\u5019\u8865\u507f\u529f\u80fd\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"oLFdCHv913W9oB2CYlFRhR\"><p class=\"q\" data-page-node-id=\"1Bi5r7fdzMMJ5xcqFp70P8\">4. 20 \u5e74\u7b97\u603b\u8d26\uff0c\u4e09\u79cd\u70ed\u6e90\u5dee\u591a\u5c11\u94b1\uff1f<\/p><p class=\"a\" data-page-node-id=\"arzVZZzlAklclkZpfNJNZu\">\u4ee5 100\u33a1\u3001\u6bcf\u5e74 120 \u5929\u4e3a\u57fa\u51c6\uff1a\u666e\u901a\u7089\u7ea6 9.50 \u4e07\u5143\u3001\u51b7\u51dd\u7089\u7ea6 8.71 \u4e07\u5143\u3001\u7a7a\u6c14\u80fd\u7ea6 6.00 \u4e07\u5143\u3002\u7a7a\u6c14\u80fd\u6700\u4f4e\uff0c\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u7701\u7ea6 0.8 \u4e07\u5143\u3002\u5dee\u522b\u4e3b\u8981\u6765\u81ea\u80fd\u6548\u6bd4\uff08\u51b7\u51dd\u7089 85%\u2013105%\u3001\u7a7a\u6c14\u80fd COP 3.0\u20134.0\uff09\u548c\u5bff\u547d\uff08\u666e\u901a\u7089 8\u201310 \u5e74\u9700\u6362 1 \u6b21\u3001\u7a7a\u6c14\u80fd 20 \u5e74\u4ee5\u4e0a\uff09\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"OsFyBLo1f03NCaC6pywpqL\"><p class=\"q\" data-page-node-id=\"DhAETRPzYomem9M2bLp819\">5. \u5730\u6696\u76d8\u7ba1\u7528 16 \u7ba1\u8fd8\u662f 20 \u7ba1\uff1f\u4e3b\u7ba1 De25 \u8fd8\u662f De32\uff1f<\/p><p class=\"a\" data-page-node-id=\"rXjdWLbUlZee5pAc2HexKA\">\u76d8\u7ba1\uff1a100\u33a1 \u4ee5\u4e0b\u7528 De16\uff0c100\u33a1 \u4ee5\u4e0a\u5927\u5e73\u5c42\/\u522b\u5885\u7528 De20\uff08\u53ef\u6df7\u7528\uff0c\u4e3b\u7ba1 20\u3001\u652f\u7ba1 16\uff09\u3002De16 \u6bcf\u56de\u8def\u6700\u4f73 60\u201390m\uff08\u4e0a\u9650 100m\uff09\uff0cDe20 \u6bcf\u56de\u8def\u6700\u4f73 80\u2013110m\uff08\u4e0a\u9650 120m\uff09\u3002\u4e3b\u7ba1\uff1a100\u33a1 \u4ee5\u4e0b\u7528 De25 \u6216 De32\uff0c100\u2013150\u33a1 \u7528 <strong data-page-node-id=\"vUYwij4U6V23IpxGF7enRo\">De32<\/strong>\uff0c<strong data-page-node-id=\"qtlDyHTiEtIzUpPNcu8Q28\">150\u33a1 \u4ee5\u4e0a\u5fc5\u987b De40<\/strong>\u2014\u2014De32 \u7684\u622a\u9762\u79ef\u662f De25 \u7684 1.6 \u500d\u3001\u6d41\u91cf\u63d0\u5347 60% \u4ee5\u4e0a\u3002\u4e3b\u7ba1\u592a\u7ec6\u662f\"\u672b\u7aef\u4e0d\u70ed\u3001\u9505\u7089\u566a\u97f3\u5927\"\u7684\u5e38\u89c1\u6839\u56e0\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"ZOEqxuBDSUN2a2HhBj1TCt\"><p class=\"q\" data-page-node-id=\"ovacJvkDZ3iD7tJPtyQ0F7\">6. \u5730\u6696\u56de\u586b\u5c42\u8981\u517b\u62a4\u591a\u4e45\uff1f\u591a\u4e45\u80fd\u70ed\u8d77\u6765\uff1f<\/p><p class=\"a\" data-page-node-id=\"vTVoKYj1RiTVBN7hiE4nBG\">\u56de\u586b\u5c42\u9700\u81ea\u7136\u517b\u62a4 <strong data-page-node-id=\"nEcIAetBdVSvlw63gLBX3T\">7 \u5929<\/strong>\uff0c\u671f\u95f4\u4e25\u7981\u8e29\u8e0f\u548c\u642c\u8fd0\u91cd\u7269\uff0c7 \u5929\u540e\u624d\u53ef\u505a\u5730\u9762\u627e\u5e73\u3002\u9996\u6b21\u4f7f\u7528\u65f6\u4f9b\u6c34\u6e29\u5ea6\u8981\u9636\u68af\u5f0f\u5347\u6e29\uff08\u6bcf\u5929\u5347 5\u2103 \u5de6\u53f3\uff09\u3002\u5730\u6696\u662f\u50a8\u70ed\u5f0f\u7cfb\u7edf\uff0c\u6b63\u5e38\u5347\u6e29\u9700\u8981 2\u20134 \u5c0f\u65f6\uff0c\u6240\u4ee5\u4e0d\u5efa\u8bae\u9891\u7e41\u5f00\u5173\u2014\u2014\u767d\u5929\u51fa\u95e8\u8c03\u4f4e\u800c\u975e\u5173\u95ed\uff0c\u53cd\u800c\u66f4\u7701\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"MhSEzqzQvOsQ71je2K350A\"><p class=\"q\" data-page-node-id=\"YDZzKYH8sCLoAj45vG0Vvu\">7. \u5730\u6696\u4f1a\u4e0d\u4f1a\u6f0f\u6c34\uff1f\u9a8c\u6536\u65f6\u600e\u4e48\u5224\u65ad\u5408\u4e0d\u5408\u683c\uff1f<\/p><p class=\"a\" data-page-node-id=\"tfLKD5iRifBFO8mWFFpWYR\">\u76d8\u7ba1\u672c\u8eab\u662f\u6574\u6839\u65e0\u63a5\u5934\u57cb\u8bbe\uff0c\u6f0f\u70b9\u591a\u5728\u5206\u96c6\u6c34\u5668\u63a5\u5934\u4e0e\u9505\u7089\u63a5\u53e3\u5904\u3002\u9a8c\u6536\u7684\u552f\u4e00\u786c\u6307\u6807\uff1a\u6ce8\u6ee1\u6c34\u540e\u7f13\u6162\u5347\u538b\u81f3 <strong data-page-node-id=\"6hOS1ueCAo0lpHO8ygQepa\">0.6MPa\uff0c\u4fdd\u538b 24 \u5c0f\u65f6\uff0c\u538b\u964d \u22640.05MPa<\/strong> \u4e3a\u5408\u683c\uff08GB 50242-2002\uff09\u3002\u53e6\u5916\u8981\u786e\u8ba4\u5206\u96c6\u6c34\u5668\u4e3a\u7ae0\u9c7c\u5f0f\u6216\u540c\u7a0b\u5f0f\uff08\u4e25\u7981\u5f02\u7a0b\uff09\u3001\u7cfb\u7edf\u6700\u9ad8\u70b9\u6709\u81ea\u52a8\u6392\u6c14\u9600\u3001\u6bcf\u56de\u8def\u957f\u5ea6\u4e0d\u8d85 100m\uff0816 \u7ba1\uff09\/120m\uff0820 \u7ba1\uff09\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"QZX7FCYNyzVjXwvIFCYmXD\"><p class=\"q\" data-page-node-id=\"qAF9MFSojXGgdbrADUuVsg\">8. \u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u662f\u600e\u4e48\u56de\u4e8b\uff1f\u80fd\u89e3\u51b3\u5417\uff1f<\/p><p class=\"a\" data-page-node-id=\"skBA3btdn8kSezmSaJIhde\">\u6839\u56e0\u662f<strong data-page-node-id=\"lEzCVR9Hi9KKJ8tELKp6JX\">\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u5927\u4e8e\u5b9e\u9645\u9700\u6c42<\/strong>\u2014\u2014\u7089\u5b50\u592a\u5927\uff0c\u70e7\u4e00\u4f1a\u513f\u5c31\u8d85\u6e29\u505c\u673a\uff0c\u51c9\u4e86\u53c8\u70b9\u706b\u3002\u4e09\u4e2a\u89e3\u6cd5\uff1a\u2460\u6362\u6210\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u66f4\u4f4e\uff09\uff1b\u2461\u589e\u52a0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff08\u5ba4\u6e29\u8fbe\u6807\u540e\u7ed9\u9505\u7089\u505c\u673a\u4fe1\u53f7\uff09\uff1b\u2462\u5927\u6d41\u91cf\u8bbe\u8ba1\uff08\u8ba9\u70ed\u91cf\u66f4\u5feb\u88ab\u8fd0\u8d70\uff0c\u5ef6\u957f\u5355\u6b21\u71c3\u70e7\u65f6\u957f\uff09\u3002\u5355\u7eaf\u6362\u66f4\u5927\u7684\u9505\u7089\u53ea\u4f1a\u66f4\u7cdf\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"mjGefUnXZHbQwob0K17VsN\"><p class=\"q\" data-page-node-id=\"R29EYcxETW4A5Lo6FCeAwa\">9. \u5730\u6696\u4e0a\u9762\u80fd\u94fa\u6728\u5730\u677f\u5417\uff1f\u4f9b\u6c34\u6e29\u5ea6\u8981\u63a7\u5236\u5728\u591a\u5c11\uff1f<\/p><p class=\"a\" data-page-node-id=\"T09FMUBw7tc6koiEVoS4jh\">\u53ef\u4ee5\uff0c\u4f46\u8981\u7528<strong data-page-node-id=\"h7ox9CMHUUMlvBqhpPuVyP\">\u5730\u6696\u4e13\u7528\u5b9e\u6728\u590d\u5408\u5730\u677f\u6216\u5f3a\u5316\u590d\u5408\u5730\u677f<\/strong>\uff0c\u4e0d\u8981\u7528\u7eaf\u5b9e\u6728\uff08\u5bfc\u70ed\u5dee\u3001\u6613\u53d8\u5f62\uff09\u3002\u4f9b\u6c34\u6e29\u5ea6\u4e0d\u5b9c\u8d85\u8fc7 45\u2103\uff0c\u94fa\u8bbe\u65f6\u5fc5\u987b\u7559\u4f38\u7f29\u7f1d\u3002\u5730\u9762\u6e29\u5ea6\u6309 JGJ 142-2012 \u63a7\u5236\u5728\u4eba\u5458\u957f\u671f\u505c\u7559\u533a \u226429\u2103\uff0c\u8212\u9002\u533a\u95f4 24\u201326\u2103\u3002<\/p><\/div>\n\n<div class=\"lm-faq\" data-page-node-id=\"INIaGXMEhu5fuzZsoteKbv\"><p class=\"q\" data-page-node-id=\"txCQLY631EytBNSnGLmn9f\">10. \u5730\u6696\u591a\u4e45\u6e05\u6d17\u4e00\u6b21\uff1f\u6bcf\u5e74\u8981\u505a\u4ec0\u4e48\u4fdd\u517b\uff1f<\/p><p class=\"a\" data-page-node-id=\"LJSD4v94IYi6sOkUvFQUVX\">\u6bcf <strong data-page-node-id=\"2jT02GMICRPykBILSN8cHp\">3\u20135 \u5e74<\/strong>\u6e05\u6d17\u4e00\u6b21\u5730\u6696\u7ba1\uff1b\u82e5\u7cfb\u7edf\u6c34\u53d1\u9ed1\u6216\u6709\u94c1\u9508\u8272\u8981\u7acb\u5373\u6e05\u6d17\u3002\u6bcf\u5e74\u4f9b\u70ed\u524d\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\uff081\u20132bar\uff09\u3001\u5404\u56de\u8def\u662f\u5426\u901a\u7545\u3001\u81ea\u52a8\u6392\u6c14\u9600\u662f\u5426\u6b63\u5e38\uff1b\u58c1\u6302\u7089\u6309\u51fa\u6c34\u6e29\u5ea6\u4fdd\u517b\uff1a\u51fa\u6c34\u4f4e\u4e8e 55\u2103 \u6bcf\u5e74\u4e00\u6b21\u300155\u2103 \u4ee5\u4e0a\u6bcf\u4e24\u5e74\u4e00\u6b21\u3002\u590f\u5b63\u4e0d\u8981\u6392\u7a7a\u7cfb\u7edf\u6c34\uff0c\u5e94\u6ee1\u6c34\u4fdd\u517b\u3002\u4f7f\u7528\u963b\u6c27\u7ba1\u80fd\u663e\u8457\u5ef6\u7f13\u7ba1\u9053\u7ed3\u57a2\uff0c5 \u5143\u7684\u5dee\u4ef7 5 \u5e74\u540e\u53ef\u80fd\u7701\u4e0b\u51e0\u5343\u5143\u6e05\u6d17\u8d39\u3002<\/p><\/div>\n\n<h2>\u5ef6\u4f38\u9605\u8bfb<\/h2>\n\n<div class=\"lm-cards\">\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\">\n    <div class=\"t\">\u5730\u6696\u77e5\u8bc6\u5e95\u5ea7 \u00b7 \u5b8c\u6574\u7248<\/div>\n    <div class=\"d\">9 \u7ae0 10 \u4e07\u5b57\uff0c\u542b 20 \u95ee\u4e0e\u8fed\u4ee3\u65e5\u5fd7<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\n    <div class=\"t\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66 V3.0<\/div>\n    <div class=\"d\">\u591a\u8054\u673a\u9009\u578b\u5b89\u88c5\u5168\u89e3<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2137\">\n    <div class=\"t\">\u6696\u6c14\u7247\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7<\/div>\n    <div class=\"d\">\u660e\u88c5\u6697\u88c5\u4e0e\u6df7\u88c5\u7981\u533a<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=601\">\n    <div class=\"t\">\u8bbe\u8ba1\u4f9d\u636e \u00b7 \u56fd\u6807\u884c\u6807\u7d22\u5f15<\/div>\n    <div class=\"d\">\u8bbe\u8ba1\u9009\u578b\u6807\u51c6\u4f9d\u636e\u603b\u89c8<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=506\">\n    <div class=\"t\">\u4e3a\u4ec0\u4e48\u5730\u6696\u4e0d\u80fd\u50cf\u7a7a\u8c03\u4e00\u6837\"\u8ba4\u54c1\u724c\"\uff1f<\/div>\n    <div class=\"d\">\u5730\u6696\u662f\u5b9a\u5236\u7cfb\u7edf\uff0c\u9505\u7089\u54c1\u724c\u53ea\u5360\u56db\u5206\u4e4b\u4e00<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1395\">\n    <div class=\"t\">\u9f99\u8109\u6696\u901a\u77e5\u8bc6\u4e2d\u5fc3<\/div>\n    <div class=\"d\">\u5168\u90e8\u77e5\u8bc6\u5e95\u5ea7\u5165\u53e3<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=14658\">\n    <div class=\"t\">\u5730\u6696\u51fa\u95ee\u9898\u600e\u4e48\u529e\uff1f<\/div>\n    <div class=\"d\">8 \u5e74\u552e\u540e\u6545\u969c\u8bb0\u5f55<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12447\">\n    <div class=\"t\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/div>\n    <div class=\"d\">\u660e\u88c5\u6697\u88c5\u9009\u578b\u4e0e\u5b89\u88c5\u89c4\u8303<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\n    <div class=\"t\">\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<\/div>\n    <div class=\"d\">\u6c34\u7cfb\u7edf\u8bbe\u8ba1\u4f9d\u636e\u4e0e\u8d85\u914d\u7387\u89c4\u8303<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12812\">\n    <div class=\"t\">\u5730\u6696\u914d\u51b7\u51dd\u7089\u8fd8\u662f\u666e\u901a\u7089\uff1f<\/div>\n    <div class=\"d\">\u4f4e\u6e29\u672b\u7aef\u624d\u53d1\u6325\u51b7\u51dd\u4ef7\u503c\uff0c20 \u5e74\u6210\u672c\u5b9e\u6d4b\u5bf9\u6bd4<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=13103#chapter2\">\n    <div class=\"t\">\u5730\u6696\u76d8\u7ba1\u662f\u7cfb\u7edf\u56db\u8981\u7d20\u91cc\u7684\u300c\u672b\u7aef\u300d<\/div>\n    <div class=\"d\">\u4e3a\u4ec0\u4e48\u95f4\u8ddd\u4e0d\u662f\u8d8a\u5bc6\u8d8a\u597d\uff1f\u8bfb\u300a\u5c45\u5bb6\u73af\u5883\u767d\u76ae\u4e66\u300b\u7b2c\u4e8c\u7ae0<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=13471\">\n    <div class=\"t\">\u5730\u6696\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\uff1a\u4e94\u6b65\u6cd5\u516c\u5f00\u7248<\/div>\n    <div class=\"d\">\u62ff\u53bb\u6838\u5bf9\u4efb\u4f55\u4e00\u5bb6\u65b9\u6848<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=13579\">\n    <div class=\"t\">\u4e2d\u592e\u7a7a\u8c03\u6c1f\u7cfb\u7edf\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\u9009\u578b<\/div>\n    <div class=\"d\">\u8bbe\u8ba1\u9009\u578b\u4e94\u6b65\u6cd5<\/div>\n  <\/a>\n\n  <a class=\"lm-card\" href=\"https:\/\/longmai-nt.com\/?page_id=13419\">\n    <div class=\"t\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009<\/div>\n    <div class=\"d\">\u6c1f\u673a \/ \u6c34\u673a\u4e00\u5f20\u8868\u770b\u61c2<\/div>\n  <\/a>\n\n<\/div>\n\n\n<h2 data-page-node-id=\"H001ZQR2r5pARNagupLqML\">\u6210\u90fd\u53cc\u95e8\u5e97 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h2>\n\n<div class=\"lm-store\" data-page-node-id=\"7SnUpmdrpNfBvBi6hnVxru\">\n<div data-page-node-id=\"mw14Il7c2x1F8Jt7Udz2x1\">\n<b data-page-node-id=\"Kwm24TVUwEInf7cnccEADl\">\u9f99\u8109\u6696\u901a \u00b7 \u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97<\/b><br data-page-node-id=\"sx5qgeF1yG3wcB4ayZ1Ntb\">\n\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97<br data-page-node-id=\"Nhh2oB9iRD6aI2zbKAxEuB\">\n\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<br data-page-node-id=\"zFF9Rm1t8d5YLPm95FZysQ\">\n\u4f59\u6653\u73b2 <a href=\"tel:13008113409\" data-page-node-id=\"qHTy9oVmagkwxdc7p7PGUM\">130-0811-3409<\/a>\uff08\u5fae\u4fe1\u540c\u53f7\uff09<br data-page-node-id=\"zKuTRk44TyMhlosAF8dgYx\">\n\u90ed\u7ecf\u7406 <a href=\"tel:18100839248\" data-page-node-id=\"mtfX7NYAl1hiUOSDpD3Wzw\">181-0083-9248<\/a>\uff08\u5fae\u4fe1\u540c\u53f7\uff09<br data-page-node-id=\"WycZdLNSRCAycNPl3Cvp5C\">\n\u95e8\u5e97\u70ed\u7ebf <a href=\"tel:02886131795\" data-page-node-id=\"nU52Pcwna8O36v4c2M2x07\">028-86131795<\/a>\n<\/div>\n<div data-page-node-id=\"r9fPbkTPilYi45ThuMWQGR\">\n<b data-page-node-id=\"Y2PPnOtgdpvvS8DaQPOwOH\">\u9f99\u8109\u6696\u901a \u00b7 \u6210\u534e\u533a\u5e97<\/b><br data-page-node-id=\"QGWHvcdFYnVDtlRny4pBH2\">\n\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986<br data-page-node-id=\"TDnya7f7WF2UCoWGm35JHq\">\n\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<br data-page-node-id=\"TEXk93QcQIS2EFgfCKL0qJ\">\n\u9ec4\u7ecf\u7406 <a href=\"tel:15828489188\" data-page-node-id=\"gYZsqG98esabUwy5Wy11Ew\">158-2848-9188<\/a>\uff08\u5fae\u4fe1\u540c\u53f7\uff09<br data-page-node-id=\"22AqKd5xdgwJBRHEeKU55N\">\n\u4f59\u7231\u82f1 <a href=\"tel:13908183204\" data-page-node-id=\"MYTEl5eHCRGxgEUSXcl1mQ\">139-0818-3204<\/a>\uff08\u5fae\u4fe1\u540c\u53f7\uff09<br data-page-node-id=\"hIHtqkv4iot8lLsEUe1ic0\">\n\u95e8\u5e97\u70ed\u7ebf <a href=\"tel:02865272586\" data-page-node-id=\"mZgIO6Boo8kvJWDd3hi2ov\">028-65272586<\/a>\n<\/div>\n<\/div>\n\n<p data-page-node-id=\"RkwTfUqybesrHg7zMmJsnl\">\n<a class=\"lm-btn lm-btn-r\" href=\"tel:02886131795\" data-page-node-id=\"XCiPvWRJcu84Nm03UjQiW5\">\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97 028-86131795<\/a>\n<a class=\"lm-btn lm-btn-d\" href=\"tel:02865272586\" data-page-node-id=\"RvYRFQ95KDZtW1GdsfmNTI\">\u6210\u534e\u533a\u5e97 028-65272586<\/a>\n<a class=\"lm-btn lm-btn-o\" href=\"https:\/\/uri.amap.com\/search?keyword=%E6%88%90%E9%83%BD%E5%B8%82%E9%AB%98%E6%96%B0%E5%8C%BA%E9%83%BD%E4%BC%9A%E8%B7%AF99%E5%8F%B7%E5%AF%8C%E6%A3%AE%E7%BE%8E%E5%AE%B6%E5%B1%85%E5%BB%BA%E6%9D%90%E9%A6%863%E6%A5%BCA348\" target=\"_blank\" rel=\"noopener\" data-page-node-id=\"PHHVc2gNAFkU7XKuCTqCWN\">\u5bfc\u822a\u5230\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97<\/a>\n<a class=\"lm-btn lm-btn-o\" href=\"https:\/\/uri.amap.com\/search?keyword=%E6%88%90%E9%83%BD%E5%B8%82%E6%88%90%E5%8D%8E%E5%8C%BA%E5%AF%8C%E6%A3%AE%E7%BE%8E%E5%AE%B6%E5%B1%85%E5%BB%BA%E6%9D%90%E9%A6%86A%E5%B9%A45%E6%A5%BCA5135%E5%8F%B7\" target=\"_blank\" rel=\"noopener\" data-page-node-id=\"TwH0HTVeJOMyt49dheOmpU\">\u5bfc\u822a\u5230\u6210\u534e\u533a\u5e97<\/a>\n<a class=\"lm-btn lm-btn-o\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\" data-page-node-id=\"s8bWBgbsxA8v9TWBscDxlK\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/a>\n<\/p>\n\n<figure class=\"lm-fig\" data-page-node-id=\"uU86W8cNiPMfLKdl0ByaBj\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store-1024x444.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store-300x130.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store-768x333.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store-1024x444.jpg 1024w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"1024\" height=\"444\">\n<figcaption data-page-node-id=\"wp5ROf52TAiFlYY62gA5yD\">\u9f99\u8109\u6696\u901a \u00b7 \u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97\uff09<\/figcaption>\n<\/figure>\n\n<figure class=\"lm-fig\" data-page-node-id=\"wB9aNcWsFJDgnsj0s8YWgm\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store-1024x434.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u6210\u534e\u533a\u5e97\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store-300x127.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store-768x326.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store-1024x434.jpg 1024w\" sizes=\"auto, (max-width:640px) 100vw, 900px\" width=\"1024\" height=\"434\">\n<figcaption data-page-node-id=\"EWbWG6D7G1kFLCl7W5hUPk\">\u9f99\u8109\u6696\u901a \u00b7 \u6210\u534e\u533a\u5e97\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986\uff09<\/figcaption>\n<\/figure>\n\n<div class=\"lm-foot\" data-page-node-id=\"3kDhJp6o1HZGKNnvfKSqoo\">\n<strong data-page-node-id=\"6aUlmVWPtLuUndq3glwZRq\">\u514d\u8d23\u58f0\u660e<\/strong>\uff1a\u672c\u9875\u4ef7\u683c\u4e0e\u8fd0\u884c\u8d39\u7528\u4e3a\u6210\u90fd\u5730\u533a\u53c2\u8003\u533a\u95f4\u4e0e\u6309\u65e2\u5b9a\u53e3\u5f84\u7684\u6d4b\u7b97\u503c\uff0c\u4e0d\u6784\u6210\u5408\u540c\u62a5\u4ef7\uff1b\u7cbe\u51c6\u914d\u7f6e\u4e0e\u6b63\u5f0f\u62a5\u4ef7\u987b\u7ecf\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u540e\u51fa\u5177\u5b8c\u6574\u65b9\u6848\u786e\u5b9a\u3002\u6280\u672f\u53c2\u6570\u4f9d\u636e GB 50736-2012\u3001JGJ 142-2012\u3001GB 50242-2002 \u7b49\u56fd\u5bb6\u6807\u51c6\u6574\u7406\uff0c\u5de5\u7a0b\u53d6\u503c\u4e0e\u7406\u8bba\u503c\u5b58\u5728\u5dee\u5f02\u65f6\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e0e\u8bbe\u5907\u5382\u5bb6\u8d44\u6599\u4e3a\u51c6\u3002<br data-page-node-id=\"vb0O6oHfdRGxikP5yG0GXh\">\n<strong data-page-node-id=\"LZ9utnSV9MOkL0xurVuRK7\">\u7248\u672c<\/strong>\uff1aV1.3\uff082026-09-13\uff09\u3000\uff5c\u3000<strong data-page-node-id=\"tnYZEAktK1f0X4pYimlsDO\">\u7f16\u5236<\/strong>\uff1a\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\n<\/div>\n\n<\/div>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66 V1.3\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3\",\n      \"description\": \"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8bb2\u6e05\u70ed\u6e90\u4e09\u9635\u8425 20 \u5e74\u603b\u6295\u5165\u5bf9\u6bd4\u3001\u76d8\u7ba1 De16\/De20 \u4e0e\u4e3b\u7ba1 De32 \u9009\u578b\u3001\u56de\u586b\u5c42\u4e0e\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\u3001GB 50736 \u4e0e JGJ 142 \u8bbe\u8ba1\u53c2\u6570\u3001\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b\u4e0e 99\/119\/169 \u5143\u6bcf\u5e73\u7c73\u53c2\u8003\u5355\u4ef7\u3002\",\n      \"author\": {\"@type\": \"Organization\", \"name\": \"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\n      \"publisher\": {\"@type\": \"Organization\", \"name\": \"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\n      \"datePublished\": \"2026-09-13\",\n      \"dateModified\": \"2026-09-13\",\n      \"inLanguage\": \"zh-CN\",\n      \"mainEntityOfPage\": {\"@type\": \"WebPage\", \"@id\": \"https:\/\/longmai-nt.com\/?page_id=12439\"}\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"itemListElement\": [\n        {\"@type\": \"ListItem\", \"position\": 1, \"name\": \"\u9996\u9875\", \"item\": \"https:\/\/longmai-nt.com\/\"},\n        {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"\u77e5\u8bc6\u4e2d\u5fc3\", \"item\": \"https:\/\/longmai-nt.com\/?page_id=1395\"},\n        {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66 V1.3\", \"item\": \"https:\/\/longmai-nt.com\/?page_id=12439\"}\n      ]\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u6210\u90fd\u5730\u6696\u591a\u5c11\u94b1\u4e00\u5e73\u7c73\uff1f66\u33a1 \u5927\u6982\u8981\u82b1\u591a\u5c11\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u6309\u5b9e\u9645\u94fa\u8bbe\u9762\u79ef\u7ed3\u7b97\uff0c\u9f99\u8109\u53c2\u8003\u5355\u4ef7\u4e3a\uff1a\u6e05\u6c34\u623f\u6807\u51c6\u5305 99 \u5143\/\u33a1\uff08\u603b\u63a7\uff09\u3001\u7cbe\u88c5\u6539\u9020 119 \u5143\/\u33a1\uff08\u5206\u63a7\uff09\u3001\u8282\u80fd\u5305 169 \u5143\/\u33a1\uff0c\u767d\u6676\u677f\u5347\u7ea7 +15 \u5143\/\u33a1\u3002\u4ee5 66\u33a1 \u8ba1\uff0c\u6807\u51c6\u5305\u7ea6 6,534 \u5143\u3001\u8282\u80fd\u5305\u7ea6 11,154 \u5143\uff0c\u5747\u4e0d\u542b\u9505\u7089\u4e3b\u673a\u3002\u9762\u79ef\u8d8a\u5c0f\u5355\u65b9\u7565\u9ad8\uff0c\u5c5e\u6b63\u5e38\u3002\u8be6\u7ec6\u53e3\u5f84\u89c1\u6210\u90fd\u5730\u6696\u4ef7\u683c\u53c2\u8003\u9875\uff0c\u4e5f\u53ef\u4ee5\u5148\u7528\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668\u81ea\u5df1\u7b97\u4e00\u7248\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u71c3\u6c14\u58c1\u6302\u7089\u3001\u7a7a\u6c14\u80fd\u3001\u7535\u5730\u6696\uff0c\u6210\u90fd\u5bb6\u5ead\u600e\u4e48\u9009\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u6709\u5929\u7136\u6c14\u3001\u8ffd\u6c42\u4f4e\u521d\u88c5\u548c\u7a33\u5b9a\u7684\u8212\u9002\u5ea6\u7684\uff0c\u9009\u51b7\u51dd\u7089\uff1b\u957f\u671f\u81ea\u4f4f\u3001\u8ffd\u6c42 20 \u5e74\u603b\u6295\u5165\u6700\u4f4e\u7684\uff0c\u9009\u7a7a\u6c14\u80fd\uff0820 \u5e74\u7ea6 6.0 \u4e07\uff0c\u6bd4\u666e\u901a\u7089\u7701\u7ea6 3.5 \u4e07\uff09\uff1b\u53ea\u5728\u536b\u751f\u95f4\u7b49 5\u201350\u33a1 \u5c40\u90e8\u8865\u5145\u91c7\u6696\u7684\uff0c\u9009\u7535\u5730\u6696\u3002\u7a7a\u6c14\u80fd\u9002\u5408 100\u33a1 \u4ee5\u4e0a\uff0c\u56e0\u4e3a\u8bbe\u5907\u6210\u672c\u8981\u644a\u8584\u624d\u5212\u7b97\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u51b7\u51dd\u7089\u4e00\u5b9a\u6bd4\u666e\u901a\u7089\u7701\u6c14\u5417\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u4e0d\u4e00\u5b9a\uff0c\u6709\u524d\u63d0\u3002\u51b7\u51dd\u7089\u5fc5\u987b\u5728\u4f4e\u6e29\u7cfb\u7edf\uff08\u4f9b\u6c34\u6e29\u5ea6 \u226455\u2103\uff09\u4e0b\u624d\u80fd\u53d1\u6325\u70ed\u6548\u7387\u4f18\u52bf\uff0c\u6240\u4ee5\u5b83\u5929\u7136\u9002\u914d\u5730\u6696\u3002\u5982\u679c\u914d\u5957\u7684\u662f\u4f20\u7edf\u9ad8\u6e29\u6696\u6c14\u7247\uff0c\u51b7\u51dd\u7089\u7684\u8282\u80fd\u4f18\u52bf\u65e0\u6cd5\u4f53\u73b0\uff0c\u7b49\u4e8e\u767d\u82b1\u94b1\u3002\u540c\u65f6\u51b7\u51dd\u7089\u5fc5\u987b\u914d\u5ba4\u5916\u6e29\u5ea6\u8865\u507f\u6216\u6c14\u5019\u8865\u507f\u529f\u80fd\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"20 \u5e74\u7b97\u603b\u8d26\uff0c\u4e09\u79cd\u70ed\u6e90\u5dee\u591a\u5c11\u94b1\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u4ee5 100\u33a1\u3001\u6bcf\u5e74 120 \u5929\u4e3a\u57fa\u51c6\uff1a\u666e\u901a\u7089\u7ea6 9.50 \u4e07\u5143\u3001\u51b7\u51dd\u7089\u7ea6 8.71 \u4e07\u5143\u3001\u7a7a\u6c14\u80fd\u7ea6 6.00 \u4e07\u5143\u3002\u7a7a\u6c14\u80fd\u6700\u4f4e\uff0c\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u7701\u7ea6 0.8 \u4e07\u5143\u3002\u5dee\u522b\u4e3b\u8981\u6765\u81ea\u80fd\u6548\u6bd4\uff08\u51b7\u51dd\u7089 85%\u2013105%\u3001\u7a7a\u6c14\u80fd COP 3.0\u20134.0\uff09\u548c\u5bff\u547d\uff08\u666e\u901a\u7089 8\u201310 \u5e74\u9700\u6362 1 \u6b21\u3001\u7a7a\u6c14\u80fd 20 \u5e74\u4ee5\u4e0a\uff09\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5730\u6696\u76d8\u7ba1\u7528 16 \u7ba1\u8fd8\u662f 20 \u7ba1\uff1f\u4e3b\u7ba1 De25 \u8fd8\u662f De32\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u76d8\u7ba1\uff1a100\u33a1 \u4ee5\u4e0b\u7528 De16\uff0c100\u33a1 \u4ee5\u4e0a\u5927\u5e73\u5c42\/\u522b\u5885\u7528 De20\uff08\u53ef\u6df7\u7528\uff0c\u4e3b\u7ba1 20\u3001\u652f\u7ba1 16\uff09\u3002De16 \u6bcf\u56de\u8def\u6700\u4f73 60\u201390m\uff08\u4e0a\u9650 100m\uff09\uff0cDe20 \u6bcf\u56de\u8def\u6700\u4f73 80\u2013110m\uff08\u4e0a\u9650 120m\uff09\u3002\u4e3b\u7ba1\uff1a\u9f99\u8109\u6807\u51c6 De32 \u8d77\u6b65\uff08\u54ea\u6015\u5c0f\u6237\u578b\u5355\u95f4\u623f\u95f4\u4e5f\u4e00\u5f8b\u5982\u6b64\uff09\uff0c150\u33a1 \u4ee5\u4e0a\u5fc5\u987b De40\u2014\u2014De32 \u7684\u622a\u9762\u79ef\u662f De25 \u7684 1.6 \u500d\u3001\u6d41\u91cf\u63d0\u5347 60% \u4ee5\u4e0a\u3002\u4e3b\u7ba1\u592a\u7ec6\u662f\u672b\u7aef\u4e0d\u70ed\u3001\u9505\u7089\u566a\u97f3\u5927\u7684\u5e38\u89c1\u6839\u56e0\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5730\u6696\u56de\u586b\u5c42\u8981\u517b\u62a4\u591a\u4e45\uff1f\u591a\u4e45\u80fd\u70ed\u8d77\u6765\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u56de\u586b\u5c42\u9700\u81ea\u7136\u517b\u62a4 7 \u5929\uff0c\u671f\u95f4\u4e25\u7981\u8e29\u8e0f\u548c\u642c\u8fd0\u91cd\u7269\uff0c7 \u5929\u540e\u624d\u53ef\u505a\u5730\u9762\u627e\u5e73\u3002\u9996\u6b21\u4f7f\u7528\u65f6\u4f9b\u6c34\u6e29\u5ea6\u8981\u9636\u68af\u5f0f\u5347\u6e29\uff08\u6bcf\u5929\u5347 5\u2103 \u5de6\u53f3\uff09\u3002\u5730\u6696\u662f\u50a8\u70ed\u5f0f\u7cfb\u7edf\uff0c\u6b63\u5e38\u5347\u6e29\u9700\u8981 2\u20134 \u5c0f\u65f6\uff0c\u6240\u4ee5\u4e0d\u5efa\u8bae\u9891\u7e41\u5f00\u5173\u2014\u2014\u767d\u5929\u51fa\u95e8\u8c03\u4f4e\u800c\u975e\u5173\u95ed\uff0c\u53cd\u800c\u66f4\u7701\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5730\u6696\u4f1a\u4e0d\u4f1a\u6f0f\u6c34\uff1f\u9a8c\u6536\u65f6\u600e\u4e48\u5224\u65ad\u5408\u4e0d\u5408\u683c\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u76d8\u7ba1\u672c\u8eab\u662f\u6574\u6839\u65e0\u63a5\u5934\u57cb\u8bbe\uff0c\u6f0f\u70b9\u591a\u5728\u5206\u96c6\u6c34\u5668\u63a5\u5934\u4e0e\u9505\u7089\u63a5\u53e3\u5904\u3002\u9a8c\u6536\u7684\u552f\u4e00\u786c\u6307\u6807\uff1a\u6ce8\u6ee1\u6c34\u540e\u7f13\u6162\u5347\u538b\u81f3 0.6MPa\uff0c\u4fdd\u538b 24 \u5c0f\u65f6\uff0c\u538b\u964d \u22640.05MPa \u4e3a\u5408\u683c\uff08GB 50242-2002\uff09\u3002\u53e6\u5916\u8981\u786e\u8ba4\u5206\u96c6\u6c34\u5668\u4e3a\u7ae0\u9c7c\u5f0f\u6216\u540c\u7a0b\u5f0f\uff08\u4e25\u7981\u5f02\u7a0b\uff09\u3001\u7cfb\u7edf\u6700\u9ad8\u70b9\u6709\u81ea\u52a8\u6392\u6c14\u9600\u3001\u6bcf\u56de\u8def\u957f\u5ea6\u4e0d\u8d85 100m\uff0816 \u7ba1\uff09\/120m\uff0820 \u7ba1\uff09\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u662f\u600e\u4e48\u56de\u4e8b\uff1f\u80fd\u89e3\u51b3\u5417\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u6839\u56e0\u662f\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u5927\u4e8e\u5b9e\u9645\u9700\u6c42\u2014\u2014\u7089\u5b50\u592a\u5927\uff0c\u70e7\u4e00\u4f1a\u513f\u5c31\u8d85\u6e29\u505c\u673a\uff0c\u51c9\u4e86\u53c8\u70b9\u706b\u3002\u4e09\u4e2a\u89e3\u6cd5\uff1a\u6362\u6210\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u66f4\u4f4e\uff09\uff1b\u589e\u52a0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff08\u5ba4\u6e29\u8fbe\u6807\u540e\u7ed9\u9505\u7089\u505c\u673a\u4fe1\u53f7\uff09\uff1b\u5927\u6d41\u91cf\u8bbe\u8ba1\uff08\u8ba9\u70ed\u91cf\u66f4\u5feb\u88ab\u8fd0\u8d70\uff0c\u5ef6\u957f\u5355\u6b21\u71c3\u70e7\u65f6\u957f\uff09\u3002\u5355\u7eaf\u6362\u66f4\u5927\u7684\u9505\u7089\u53ea\u4f1a\u66f4\u7cdf\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5730\u6696\u4e0a\u9762\u80fd\u94fa\u6728\u5730\u677f\u5417\uff1f\u4f9b\u6c34\u6e29\u5ea6\u8981\u63a7\u5236\u5728\u591a\u5c11\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u53ef\u4ee5\uff0c\u4f46\u8981\u7528\u5730\u6696\u4e13\u7528\u5b9e\u6728\u590d\u5408\u5730\u677f\u6216\u5f3a\u5316\u590d\u5408\u5730\u677f\uff0c\u4e0d\u8981\u7528\u7eaf\u5b9e\u6728\uff08\u5bfc\u70ed\u5dee\u3001\u6613\u53d8\u5f62\uff09\u3002\u4f9b\u6c34\u6e29\u5ea6\u4e0d\u5b9c\u8d85\u8fc7 45\u2103\uff0c\u94fa\u8bbe\u65f6\u5fc5\u987b\u7559\u4f38\u7f29\u7f1d\u3002\u5730\u9762\u6e29\u5ea6\u6309 JGJ 142-2012 \u63a7\u5236\u5728\u4eba\u5458\u957f\u671f\u505c\u7559\u533a \u226429\u2103\uff0c\u8212\u9002\u533a\u95f4 24\u201326\u2103\u3002\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5730\u6696\u591a\u4e45\u6e05\u6d17\u4e00\u6b21\uff1f\u6bcf\u5e74\u8981\u505a\u4ec0\u4e48\u4fdd\u517b\uff1f\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"\u6bcf 3\u20135 \u5e74\u6e05\u6d17\u4e00\u6b21\u5730\u6696\u7ba1\uff1b\u82e5\u7cfb\u7edf\u6c34\u53d1\u9ed1\u6216\u6709\u94c1\u9508\u8272\u8981\u7acb\u5373\u6e05\u6d17\u3002\u6bcf\u5e74\u4f9b\u70ed\u524d\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\uff081\u20132bar\uff09\u3001\u5404\u56de\u8def\u662f\u5426\u901a\u7545\u3001\u81ea\u52a8\u6392\u6c14\u9600\u662f\u5426\u6b63\u5e38\uff1b\u58c1\u6302\u7089\u6309\u51fa\u6c34\u6e29\u5ea6\u4fdd\u517b\uff1a\u51fa\u6c34\u4f4e\u4e8e 55\u2103 \u6bcf\u5e74\u4e00\u6b21\u300155\u2103 \u4ee5\u4e0a\u6bcf\u4e24\u5e74\u4e00\u6b21\u3002\u590f\u5b63\u4e0d\u8981\u6392\u7a7a\u7cfb\u7edf\u6c34\uff0c\u5e94\u6ee1\u6c34\u4fdd\u517b\u3002\u4f7f\u7528\u963b\u6c27\u7ba1\u80fd\u663e\u8457\u5ef6\u7f13\u7ba1\u9053\u7ed3\u57a2\uff0c5 \u5143\u7684\u5dee\u4ef7 5 \u5e74\u540e\u53ef\u80fd\u7701\u4e0b\u51e0\u5343\u5143\u6e05\u6d17\u8d39\u3002\"}\n        }\n      ]\n    },\n    {\n      \"@type\": \"LocalBusiness\",\n      \"name\": \"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n      \"image\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\n      \"telephone\": \"+86-28-86131795\",\n      \"address\": {\"@type\": \"PostalAddress\", \"streetAddress\": \"\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348\", \"addressLocality\": \"\u6210\u90fd\u5e02\", \"addressRegion\": \"\u56db\u5ddd\u7701\", \"addressCountry\": \"CN\"},\n      \"geo\": {\"@type\": \"GeoCoordinates\", \"latitude\": 30.5728, \"longitude\": 104.0668},\n      \"url\": \"https:\/\/longmai-nt.com\/\",\n      \"openingHours\": \"Mo-Su 09:00-18:00\",\n      \"hasMap\": \"https:\/\/uri.amap.com\/search?keyword=%E6%88%90%E9%83%BD%E5%B8%82%E9%AB%98%E6%96%B0%E5%8C%BA%E9%83%BD%E4%BC%9A%E8%B7%AF99%E5%8F%B7%E5%AF%8C%E6%A3%AE%E7%BE%8E%E5%AE%B6%E5%B1%85%E5%BB%BA%E6%9D%90%E9%A6%863%E6%A5%BCA348\",\n      \"department\": {\n        \"@type\": \"LocalBusiness\",\n        \"name\": \"\u9f99\u8109\u6696\u901a \u00b7 \u6210\u534e\u533a\u5e97\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986\uff09\",\n        \"telephone\": \"+86-28-65272586\",\n        \"address\": {\"@type\": \"PostalAddress\", \"streetAddress\": \"\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7\", \"addressLocality\": \"\u6210\u90fd\u5e02\", \"addressRegion\": \"\u56db\u5ddd\u7701\", \"addressCountry\": \"CN\"},\n        \"hasMap\": \"https:\/\/uri.amap.com\/search?keyword=%E6%88%90%E9%83%BD%E5%B8%82%E6%88%90%E5%8D%8E%E5%8C%BA%E5%AF%8C%E6%A3%AE%E7%BE%8E%E5%AE%B6%E5%B1%85%E5%BB%BA%E6%9D%90%E9%A6%86A%E5%B9%A45%E6%A5%BCA5135%E5%8F%B7\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u7248\u672c\uff1aV1.3\u3000\uff5c\u3000\u66f4\u65b0\u65e5\u671f\uff1a2026- [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-12439","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8be6\u89e3\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4e8c\u6b21\u7cfb\u7edf\u5224\u522b\u3001\u65bd\u5de5\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u5957\u9910\u5355\u4ef7\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=12439\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8be6\u89e3\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4e8c\u6b21\u7cfb\u7edf\u5224\u522b\u3001\u65bd\u5de5\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u5957\u9910\u5355\u4ef7\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=12439\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-18T16:25:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-1024x576.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439\",\"name\":\"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-yxl-yxlzybjt-01-1-1024x576.png\",\"datePublished\":\"2026-09-12T16:58:47+00:00\",\"dateModified\":\"2026-10-18T16:25:22+00:00\",\"description\":\"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8be6\u89e3\u58c1\u6302\u7089\\\/\u7a7a\u6c14\u80fd\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4e8c\u6b21\u7cfb\u7edf\u5224\u522b\u3001\u65bd\u5de5\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u5957\u9910\u5355\u4ef7\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-yxl-yxlzybjt-01-1.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-yxl-yxlzybjt-01-1.png\",\"width\":2191,\"height\":1232,\"caption\":\"\u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u80cc\u666f\u56fe\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12439#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8be6\u89e3\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4e8c\u6b21\u7cfb\u7edf\u5224\u522b\u3001\u65bd\u5de5\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u5957\u9910\u5355\u4ef7\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=12439","og_locale":"zh_CN","og_type":"article","og_title":"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8be6\u89e3\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4e8c\u6b21\u7cfb\u7edf\u5224\u522b\u3001\u65bd\u5de5\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u5957\u9910\u5355\u4ef7\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=12439","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-18T16:25:22+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-1024x576.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"10 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=12439","url":"https:\/\/longmai-nt.com\/?page_id=12439","name":"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=12439#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=12439#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1-1024x576.png","datePublished":"2026-09-12T16:58:47+00:00","dateModified":"2026-10-18T16:25:22+00:00","description":"\u6210\u90fd\u5730\u6696\u767d\u76ae\u4e66\uff0c\u8be6\u89e3\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u7ba1\u5f84\u3001\u4e8c\u6b21\u7cfb\u7edf\u5224\u522b\u3001\u65bd\u5de5\u6253\u538b\u9a8c\u6536\u7ea2\u7ebf\uff0c20\u5e74\u5168\u5468\u671f\u6210\u672c\u6d4b\u7b97\uff0c\u9644\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u5957\u9910\u5355\u4ef7\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=12439#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=12439"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=12439#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1.png","width":2191,"height":1232,"caption":"\u65e5\u7acb\u4e24\u8054\u4f9b\u5730\u6696\u80cc\u666f\u56fe"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=12439#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\u3001\u76d8\u7ba1\u8bbe\u8ba1\u3001\u65bd\u5de5\u9a8c\u6536\u4e0e 20 \u5e74\u6210\u672c\u5168\u89e3"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/12439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=12439"}],"version-history":[{"count":15,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/12439\/revisions"}],"predecessor-version":[{"id":15670,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/12439\/revisions\/15670"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=12439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}