{"id":12501,"date":"2026-09-13T22:38:37","date_gmt":"2026-09-13T14:38:37","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=12501"},"modified":"2026-09-13T23:39:48","modified_gmt":"2026-09-13T15:39:48","slug":"%e6%9d%8e%e5%a5%b3%e5%a3%ab-%c2%b7-%e5%85%a8%e5%b1%8b%e5%9c%b0%e6%9a%96%e7%b3%bb%e7%bb%9f%e6%96%b9%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=12501","title":{"rendered":"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66"},"content":{"rendered":"\n<!-- \u9f99\u8109\u6696\u901a \u00b7 \u674e\u5973\u58eb\u5168\u5c4b\u5730\u6696\u65b9\u6848\u4e66\uff08WordPress \u5355\u5757\u7c98\u8d34\u7248\uff09-->\n<style>\n.lm-scope{box-sizing:border-box}\n.lm-scope{--bg:#f5f3ee;--card:#fff;--card2:#efeade;--line:#e4ded1;--gold:#9c7a3c;--gold-2:#8a6a2f;--gold-dim:#bfae8a;--txt:#2b2b2b;--txt-dim:#6f6b63;--ok:#2e8b57;--warn:#c8860d}.lm-scope *{box-sizing:border-box;margin:0;padding:0}.lm-scope{background:var(--bg);color:var(--txt);font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;line-height:1.75}.lm-scope .wrap{max-width:980px;margin:0 auto;padding:32px 20px 80px}.lm-scope .hero{text-align:center;padding:40px 20px;border-bottom:1px solid var(--line);margin-bottom:28px}.lm-scope .hero h1{font-size:27px;color:var(--gold-2);letter-spacing:1px;font-weight:700}.lm-scope .hero .sub{color:var(--txt-dim);margin-top:8px;font-size:15px}.lm-scope .hero .meta{display:flex;flex-wrap:wrap;gap:10px 24px;justify-content:center;margin-top:18px;font-size:13px;color:var(--txt-dim)}.lm-scope .hero .meta b{color:var(--gold);font-weight:600}.lm-scope .brand{margin-top:14px;font-size:12px;color:var(--gold-dim)}.lm-scope \/* ===== \u9876\u90e8\u76ee\u5f55\u5bfc\u822a ===== *\/\n.tocbar{position:sticky;top:0;z-index:1000;display:flex;align-items:center;overflow-x:auto;white-space:nowrap;height:50px;padding:0 14px;margin-bottom:6px;background:rgba(255,255,255,.95);border-bottom:2px solid var(--gold);box-shadow:0 2px 10px rgba(120,100,60,.12);backdrop-filter:blur(8px)}.lm-scope .tocbar::-webkit-scrollbar{height:2px}.lm-scope .tocbar::-webkit-scrollbar-thumb{background:var(--gold)}.lm-scope .tocbar a{display:inline-flex;align-items:center;height:50px;padding:0 13px;font-size:13px;font-weight:500;letter-spacing:.3px;color:var(--txt-dim);text-decoration:none;border-bottom:2px solid transparent;transition:all .25s;flex:0 0 auto}.lm-scope .tocbar a:hover{color:var(--txt);background:rgba(156,122,60,.08)}.lm-scope .tocbar a.on{color:var(--gold-2);border-bottom-color:var(--gold);background:rgba(156,122,60,.12)}.lm-scope section[id],.lm-scope header[id]{scroll-margin-top:62px}.lm-scope \/* ===== \u4ea7\u54c1\u56fe\uff08\u5c3a\u5bf8\u7edf\u4e00\uff09 ===== *\/\n.prod-fig{margin:8px 0 0;text-align:center}.lm-scope .prod-fig img{display:block;width:100%;height:170px;object-fit:contain;background:#fff;border:1px solid var(--line);border-radius:8px;padding:8px}.lm-scope .prod-fig figcaption{font-size:12px;color:var(--txt-dim);margin-top:5px;line-height:1.5}.lm-scope \/* ===== \u7ffb\u8f6c\u4ea7\u54c1\u5361\u724c ===== *\/\n.flip-wrap{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:18px 0}.lm-scope .flip-card{perspective:1400px;height:440px;cursor:pointer}.lm-scope .flip-inner{position:relative;width:100%;height:100%;transition:transform .6s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d}.lm-scope .flip-card.flipped .flip-inner{transform:rotateY(180deg)}.lm-scope .flip-face{position:absolute;inset:0;backface-visibility:hidden;-webkit-backface-visibility:hidden;border-radius:12px;padding:22px;box-sizing:border-box;display:flex;flex-direction:column;overflow:hidden}.lm-scope .flip-front{background:var(--card);border:1px solid var(--line)}.lm-scope .flip-back{background:linear-gradient(135deg,#fdf9f0,#fff);border:1px solid var(--gold-dim);transform:rotateY(180deg)}.lm-scope .flip-badge{align-self:flex-start;padding:3px 13px;border-radius:20px;font-size:12px;font-weight:700;color:#fff;margin-bottom:10px}.lm-scope .flip-rec{background:linear-gradient(135deg,var(--gold),var(--gold-2))}.lm-scope .flip-alt{background:#7a6a4a}.lm-scope .flip-name{font-size:16.5px;font-weight:700;color:var(--gold-2)}.lm-scope .flip-sub{font-size:13px;color:var(--txt-dim);margin:4px 0 12px}.lm-scope .flip-front .prod-fig{margin-top:auto}.lm-scope .flip-front .prod-fig img{height:196px}.lm-scope .flip-hint{margin-top:10px;font-size:12px;color:var(--gold-dim);text-align:center}.lm-scope .flip-back-ttl{font-size:15px;font-weight:700;color:var(--gold-2);margin-bottom:12px}.lm-scope .flip-list{margin:0;padding-left:18px;font-size:13.5px;color:var(--txt)}.lm-scope .flip-list li{margin-bottom:9px}.lm-scope .flip-price{margin-top:auto;font-size:13.5px;color:var(--txt);border-top:1px dashed var(--line);padding-top:12px;text-align:center}.lm-scope .flip-price b{color:var(--gold-2);font-size:17px}.lm-scope .flip-price span{font-size:12px;color:var(--txt-dim)}@media(max-width:820px){.lm-scope .flip-wrap{grid-template-columns:1fr}.lm-scope .flip-card{height:430px}}.lm-scope \/* ===== \u6388\u6743\u8bc1\u4e66 ===== *\/\n.certs{display:grid;grid-template-columns:repeat(5,1fr);gap:12px;margin:16px 0}.lm-scope .certs figure{margin:0;text-align:center}.lm-scope .certs img{width:100%;height:210px;object-fit:contain;background:#fff;border:1px solid var(--line);border-radius:8px;padding:6px}.lm-scope .certs figcaption{font-size:11.5px;color:var(--txt-dim);margin-top:6px;line-height:1.45}.lm-scope \/* ===== \u95e8\u5e97\u4fe1\u606f\u677f\u5757 ===== *\/\n.store-sec{background:var(--card);border:1px solid var(--line);border-radius:12px;padding:26px 22px}.lm-scope .store-contacts{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:14px 0}.lm-scope .sc-item{display:flex;align-items:center;gap:10px;padding:12px 14px;border:1px solid var(--line);border-radius:8px;background:#faf8f3;text-decoration:none;transition:all .25s}.lm-scope .sc-item:hover{border-color:var(--gold);background:rgba(156,122,60,.07)}.lm-scope .sc-ic{width:32px;height:32px;background:linear-gradient(135deg,var(--gold),var(--gold-2));color:#fff;border-radius:8px;display:grid;place-items:center;font-size:15px;flex:0 0 auto}.lm-scope .sc-info{display:flex;flex-direction:column}.lm-scope .sc-label{font-size:12px;color:var(--txt-dim)}.lm-scope .sc-phone{font-size:14.5px;font-weight:700;color:var(--gold-2)}.lm-scope .store-grid{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:6px 0 16px}.lm-scope .store-card{border:1px solid var(--line);border-radius:10px;overflow:hidden;background:#fff}.lm-scope .store-label{padding:8px 14px;background:var(--card2);font-size:14px;font-weight:600;color:var(--gold-2);border-bottom:1px solid var(--line)}.lm-scope .store-card img{width:100%;height:200px;object-fit:cover;display:block}.lm-scope .store-addr{padding:10px 14px;font-size:13px;color:var(--txt-dim)}.lm-scope .store-cta{text-align:center;padding-top:4px}.lm-scope .store-cta a{display:inline-flex;align-items:center;gap:6px;padding:12px 34px;background:linear-gradient(135deg,var(--gold),var(--gold-2));color:#fff;border-radius:30px;font-size:15px;font-weight:700;text-decoration:none;box-shadow:0 4px 14px rgba(156,122,60,.28)}.lm-scope .store-cta a:hover{transform:translateY(-1px)}@media(max-width:820px){.lm-scope .store-contacts{grid-template-columns:1fr 1fr}.lm-scope .store-grid{grid-template-columns:1fr}.lm-scope .store-card img{height:160px}.lm-scope .certs{grid-template-columns:1fr 1fr}.lm-scope .certs img{height:170px}}.lm-scope section{margin:46px 0}.lm-scope .sec-h{display:flex;align-items:center;gap:12px;margin-bottom:18px}.lm-scope .sec-h .no{background:linear-gradient(135deg,var(--gold),var(--gold-2));color:#fff;font-weight:700;width:34px;height:34px;border-radius:8px;display:grid;place-items:center;font-size:15px;flex:0 0 auto}.lm-scope .sec-h h2{font-size:21px;color:var(--gold-2)}.lm-scope .sec-h .tag{margin-left:auto;font-size:12px;color:var(--txt-dim);border:1px solid var(--line);padding:3px 10px;border-radius:20px}.lm-scope .infocard{background:var(--card);border:1px solid var(--line);border-radius:12px;padding:18px 20px;display:grid;grid-template-columns:repeat(2,1fr);gap:10px 24px}.lm-scope .infocard .row{display:flex;gap:8px;font-size:14px}.lm-scope .infocard .row .k{color:var(--txt-dim);min-width:74px;flex:0 0 auto}.lm-scope .infocard .full{grid-column:1\/-1}.lm-scope .tbl{width:100%;border-collapse:collapse;margin:14px 0;font-size:13.5px;background:var(--card);border-radius:10px;overflow:hidden}.lm-scope .tbl th,.lm-scope .tbl td{border:1px solid var(--line);padding:10px 12px;text-align:left;vertical-align:top}.lm-scope .tbl th{background:var(--card2);color:var(--gold-2);font-weight:600}.lm-scope .tbl tr:nth-child(even) td{background:#faf8f3}.lm-scope .callout{border-left:3px solid var(--gold);background:var(--card);padding:14px 18px;border-radius:0 10px 10px 0;margin:14px 0;font-size:14px}.lm-scope .callout .ttl{color:var(--gold-2);font-weight:600;margin-bottom:6px}.lm-scope .grid3{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;margin:16px 0}.lm-scope .grid2{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:16px 0}.lm-scope \/* ===== \u7cbe\u5de5\u516d\u6b65\u6cd5 ===== *\/\n.sixstep{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:16px 0}.lm-scope .sixstep .step{border:1px solid var(--line);border-radius:10px;padding:14px;background:#faf8f3}.lm-scope .sixstep .step .ord{display:inline-grid;place-items:center;width:30px;height:30px;border-radius:8px;background:linear-gradient(135deg,var(--gold),var(--gold-2));color:#fff;font-weight:700;font-size:13px;margin-bottom:8px}.lm-scope .sixstep .step.extra .ord{background:#7a6a4a}.lm-scope .sixstep .step .tt{font-size:14px;font-weight:700;color:var(--gold-2);margin-bottom:5px}.lm-scope .sixstep .step .dd{font-size:12.5px;color:var(--txt-dim);line-height:1.6}.lm-scope .sixstep .step .dd b{color:var(--gold-2)}.lm-scope .sixstep .step .imgs{display:grid;grid-template-columns:1fr;gap:6px;margin:8px 0}.lm-scope .sixstep .step .imgs.two{grid-template-columns:1fr 1fr}.lm-scope .sixstep .step .imgs img{width:100%;height:104px;object-fit:cover;border-radius:8px;border:1px solid var(--line);display:block;background:#fff}@media(max-width:820px){.lm-scope .grid3{grid-template-columns:1fr}.lm-scope .grid2{grid-template-columns:1fr}.lm-scope .sixstep{grid-template-columns:1fr 1fr}}.lm-scope .card{border:1px solid var(--line);border-radius:12px;background:var(--card);padding:16px 18px;box-shadow:0 1px 3px rgba(0,0,0,.04)}.lm-scope .card .ct{color:var(--gold-2);font-weight:700;font-size:15px;margin-bottom:8px}.lm-scope .card ul{margin-left:18px;font-size:13.5px;color:var(--txt)}.lm-scope .card li{margin-bottom:5px}.lm-scope .total{background:linear-gradient(135deg,#fdf9f0,#fff);border:1px solid var(--gold-dim);border-radius:12px;padding:18px 22px;margin:16px 0}.lm-scope .total .ttl{color:var(--gold-2);font-weight:700;margin-bottom:10px}.lm-scope .total table{width:100%;font-size:14px}.lm-scope .total td{border-bottom:1px solid var(--line);padding:8px 4px}.lm-scope .total td:last-child{text-align:right;color:var(--gold-2);font-weight:600}.lm-scope .trust{border:1px dashed var(--gold-dim);border-radius:10px;padding:14px 18px;background:#fbf7ee;font-size:13.5px;color:var(--txt-dim)}.lm-scope .trust b{color:var(--gold-2)}.lm-scope .bad{color:#b04a4a;font-weight:600}.lm-scope .good{color:var(--ok);font-weight:600}.lm-scope .verify{font-size:13px;background:var(--card);border:1px solid var(--line);border-radius:10px;padding:14px 18px}.lm-scope .verify .ok{color:var(--ok)}.lm-scope .src-link{color:var(--gold-2);text-decoration:underline}.lm-scope .note{font-size:12px;color:var(--gold-dim);border-top:1px dashed var(--line);margin-top:50px;padding-top:14px}.lm-scope .footaddr{font-size:12.5px;color:var(--txt-dim);margin-top:10px}.lm-scope h3.st{color:var(--gold-2);margin:18px 0 8px;font-size:16px}.lm-scope \/* ===== \u2460 \u82f1\u96c4\u680f\u80cc\u666f\u56fe ===== *\/\n.hero{position:relative;padding:66px 24px 56px;margin-bottom:28px;border-bottom:0;border-radius:14px;overflow:hidden;text-align:center;background-image:linear-gradient(rgba(18,26,36,.55),rgba(18,26,36,.70)),url(\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-yxl-yxlzybjt-01-1.png\");background-size:cover;background-position:center;background-repeat:no-repeat;box-shadow:0 10px 30px rgba(20,30,45,.22)}.lm-scope .hero h1{color:#fff;text-shadow:0 2px 12px rgba(0,0,0,.35)}.lm-scope .hero .sub{color:rgba(255,255,255,.9)}.lm-scope .hero .meta{color:rgba(255,255,255,.85)}.lm-scope .hero .meta b{color:#f4d79a}.lm-scope .hero .brand{color:rgba(255,255,255,.72)}.lm-scope \/* ===== \u2461 \u516d\u6b65\u6cd5 PPT \u8f6e\u64ad ===== *\/\n.ppt{position:relative;border:1px solid var(--line);border-radius:12px;background:var(--card);overflow:hidden;margin:16px 0;box-shadow:0 2px 12px rgba(20,30,45,.06)}.lm-scope .ppt-stage{position:relative;overflow:hidden;transition:height .4s ease}.lm-scope .ppt-slide{display:none;padding:24px}.lm-scope .ppt-slide.is-active{display:block;animation:lm-pptIn .45s ease both}@keyframes lm-pptIn{from{opacity:0;transform:translateX(26px)}to{opacity:1;transform:none}}.lm-scope .ppt-head{display:flex;align-items:center;gap:12px;margin-bottom:14px}.lm-scope .ppt-ord{display:inline-grid;place-items:center;min-width:40px;height:40px;padding:0 9px;border-radius:10px;background:linear-gradient(135deg,var(--gold),var(--gold-2));color:#fff;font-weight:700;font-size:15px}.lm-scope .ppt-slide.extra .ppt-ord{background:#7a6a4a}.lm-scope .ppt-title{font-size:18px;font-weight:700;color:var(--gold-2)}.lm-scope .ppt-imgs{display:flex;flex-wrap:wrap;gap:12px;justify-content:center;margin:6px 0 16px}.lm-scope .ppt-fig{width:282px;margin:0;border:1px solid var(--line);border-radius:8px;overflow:hidden;background:#fff;box-shadow:0 1px 4px rgba(20,30,45,.06)}.lm-scope .ppt-fig img{width:100%;height:172px;object-fit:contain;display:block;background:#faf8f3}.lm-scope .ppt-fig figcaption{padding:6px 9px;font-size:11.5px;color:var(--txt-dim);text-align:center}.lm-scope .ppt-desc{font-size:13.5px;color:var(--txt);line-height:1.75;margin-top:8px}.lm-scope .ppt-desc b{color:var(--gold-2)}.lm-scope .ppt-arrow{position:absolute;top:calc(50% - 26px);transform:translateY(-50%);width:54px;height:54px;border-radius:50%;border:1px solid var(--line);background:rgba(255,255,255,.95);color:var(--gold-2);font-size:28px;line-height:1;cursor:pointer;display:grid;place-items:center;box-shadow:0 4px 16px rgba(20,30,45,.18);transition:background .2s,color .2s,transform .2s;z-index:6;padding:0}.lm-scope .ppt-arrow:hover{background:var(--gold);color:#fff;border-color:var(--gold);transform:translateY(-50%) scale(1.08)}.lm-scope .ppt-prev{left:14px}.lm-scope .ppt-next{right:14px}.lm-scope .ppt-nav{display:flex;align-items:center;justify-content:center;gap:16px;padding:12px;border-top:1px solid var(--line);background:#faf8f3}.lm-scope .ppt-btn{width:36px;height:36px;border-radius:50%;border:1px solid var(--line);background:#fff;color:var(--gold-2);font-size:18px;cursor:pointer;display:grid;place-items:center;transition:all .2s;line-height:1}.lm-scope .ppt-btn:hover{background:var(--gold);color:#fff;border-color:var(--gold)}.lm-scope .ppt-dots{display:flex;gap:8px;align-items:center}.lm-scope .ppt-dot{width:9px;height:9px;border-radius:50%;background:var(--line);cursor:pointer;transition:all .25s}.lm-scope .ppt-dot.on{background:var(--gold);transform:scale(1.35)}.lm-scope .ppt-count{font-size:12.5px;color:var(--txt-dim);min-width:48px;text-align:center}.lm-scope \/* ===== \u2462 \u7089\u578b\u5bf9\u6bd4\u6761\u5f62 ===== *\/\n.vsdia{margin:16px 0;border:1px solid var(--line);border-radius:12px;background:var(--card);padding:8px 18px}.lm-scope .vsrow{border-bottom:1px solid var(--line);padding:12px 0}.lm-scope .vsrow:last-child{border-bottom:0}.lm-scope .vsrow .vsname{font-size:13.5px;font-weight:600;color:var(--gold-2);margin-bottom:8px}.lm-scope .vsline{display:flex;align-items:center;gap:10px;margin:6px 0}.lm-scope .vsline .vswho{width:56px;flex:0 0 auto;font-size:12.5px;color:var(--txt-dim);text-align:right}.lm-scope .vsline .vstrack{flex:1;height:20px;background:var(--card2);border-radius:10px;overflow:hidden}.lm-scope .vsline .vsbar{display:block;height:100%;width:0;border-radius:10px;transition:width 1.1s cubic-bezier(.3,.7,.3,1)}.lm-scope .vsline.a .vsbar{background:linear-gradient(90deg,#cdbb95,#b9a377)}.lm-scope .vsline.b .vsbar{background:linear-gradient(90deg,#3f8f5f,#6fae85)}.lm-scope .vsline .vsval{width:196px;flex:0 0 auto;font-size:12.5px;color:var(--txt);transition:font-size .3s,color .3s}.lm-scope .vsrow.play .vsline.a .vsbar{width:var(--wa)}.lm-scope .vsrow.play .vsline.b .vsbar{width:var(--wb)}.lm-scope .vsline.win .vsval{font-weight:700;color:var(--gold-2);font-size:13.5px}.lm-scope .vsline.win .vsbar{box-shadow:inset 0 0 0 2px rgba(90,70,30,.28)}.lm-scope .vsrow.play .vsline.win .vsbar{transition-delay:.22s}.lm-scope .vsline.win .vswho{color:var(--gold-2);font-weight:700}.lm-scope .vsnote{font-size:11.5px;color:var(--txt-dim);margin:10px 0 4px;line-height:1.6}.lm-scope \/* ===== \u7089\u578b\u5bf9\u6bd4\u96f7\u8fbe\u56fe ===== *\/\n.radar-box{border:1px solid var(--line);border-radius:12px;background:var(--card);padding:10px 16px 6px;margin:16px 0}.lm-scope .radar-canvas{width:100%;height:400px}.lm-scope .radar-legend{display:flex;gap:24px;justify-content:center;padding:6px 0 14px;font-size:13px;color:var(--txt)}.lm-scope .radar-legend .dot{display:inline-block;width:11px;height:11px;border-radius:3px;margin-right:7px;vertical-align:-1px}.lm-scope .radar-legend .dot.a{background:#c8a24a}.lm-scope .radar-legend .dot.b{background:#3f8f5f}.lm-scope .radar-notes{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:16px 0}.lm-scope .radar-notes .rn-col{border:1px solid var(--line);border-radius:10px;background:var(--card);padding:14px 16px}.lm-scope .radar-notes .rn-tt{font-size:14px;font-weight:700;color:var(--gold-2);margin-bottom:8px}.lm-scope .radar-notes ul{margin:0;padding-left:18px;font-size:13px;color:var(--txt)}.lm-scope .radar-notes li{margin-bottom:6px}@media(max-width:820px){.lm-scope .radar-canvas{height:340px}.lm-scope .radar-notes{grid-template-columns:1fr}}.lm-scope \/* ===== \u2463 \u56db\u5927\u8981\u7d20\u52a8\u6001\u8fdb\u5ea6 ===== *\/\n.flow4{border:1px solid var(--line);border-radius:12px;background:var(--card);padding:30px 24px 20px;margin:16px 0}.lm-scope .flow4-line{position:relative;display:flex;justify-content:space-between;align-items:flex-start}.lm-scope .flow4-line::before{content:\"\";position:absolute;left:40px;right:40px;top:21px;height:6px;border-radius:3px;background:var(--card2)}.lm-scope .flow4-fill{position:absolute;left:40px;top:21px;height:6px;border-radius:3px;background:linear-gradient(90deg,var(--gold),var(--gold-2));width:0;transition:width .7s ease;z-index:1}.lm-scope .flow4-node{position:relative;z-index:2;display:flex;flex-direction:column;align-items:center;gap:7px;width:80px;cursor:pointer}.lm-scope .flow4-node .ic{width:44px;height:44px;border-radius:50%;display:grid;place-items:center;font-size:19px;background:#fff;border:2px solid var(--line);transition:all .35s}.lm-scope .flow4-node .nm{font-size:12.5px;color:var(--txt-dim);transition:all .35s}.lm-scope .flow4-node.on .ic{border-color:var(--gold);background:linear-gradient(135deg,var(--gold),var(--gold-2));transform:scale(1.1);box-shadow:0 5px 16px rgba(156,122,60,.32)}.lm-scope .flow4-node.on .nm{color:var(--gold-2);font-weight:700}.lm-scope .flow4-detail{margin-top:24px;border-top:1px dashed var(--line);padding-top:16px;min-height:120px}.lm-scope .flow4-detail .fd-tt{font-size:15px;font-weight:700;color:var(--gold-2);margin-bottom:8px;display:flex;align-items:center;gap:8px}.lm-scope .flow4-detail ul{margin:0;padding-left:18px;font-size:13.5px;color:var(--txt)}.lm-scope .flow4-detail li{margin-bottom:6px}.lm-scope .flow4-detail.show{animation:lm-fdIn .5s ease both}@keyframes lm-fdIn{from{opacity:0;transform:translateX(var(--dx,20px))}to{opacity:1;transform:none}}@media(max-width:820px){.lm-scope .vsline .vsval{width:118px;font-size:11.5px}.lm-scope .vsline .vswho{width:44px}.lm-scope .ppt-fig{width:calc(50% - 6px)}.lm-scope .ppt-fig img{height:140px}.lm-scope .flow4-node{width:60px}.lm-scope .flow4-node .ic{width:38px;height:38px;font-size:16px}}\n<\/style>\n\n<div class=\"lm-scope\">\n<nav class=\"tocbar\" id=\"tocbar\">\n  <a href=\"#top\">\u5c01\u9762<\/a>\n  <a href=\"#s1\">\u9700\u6c42\u8bca\u65ad<\/a>\n  <a href=\"#s2\">\u7cfb\u7edf\u89c2<\/a>\n  <a href=\"#s3\">\u4e13\u4e1a vs \u901a\u914d<\/a>\n  <a href=\"#s4\">\u672b\u7aef\u8bbe\u8ba1<\/a>\n  <a href=\"#s5\">\u70ed\u6e90\u9009\u578b<\/a>\n  <a href=\"#s6\">\u63a7\u5236\u7cfb\u7edf<\/a>\n  <a href=\"#s7\">\u900f\u660e\u62a5\u4ef7<\/a>\n  <a href=\"#s8\">\u65bd\u5de5\u4e0e20\u5e74\u8d26<\/a>\n  <a href=\"#summary\">\u603b\u7ed3\u5efa\u8bae<\/a>\n  <a href=\"#verify\">\u6570\u636e\u6e90<\/a>\n  <a href=\"#stores\">\u95e8\u5e97\u8054\u7cfb<\/a>\n<\/nav>\n<div class=\"wrap\">\n\n<header class=\"hero\" id=\"top\">\n  <h1>\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66<\/h1>\n  <div class=\"sub\">\u4e13\u4e1a\u8282\u80fd\u8bbe\u8ba1 \u00b7 \u51b7\u70ed\u6e90\u7cbe\u51c6\u9009\u578b \u00b7 20\u5e74\u7701\u5fc3<\/div>\n  <div class=\"meta\">\n    <span>\u5ba2\u6237\uff1a<b>\u674e\u5973\u58eb<\/b><\/span>\n    <span>\u91c7\u6696\u9762\u79ef\uff1a<b>71\u33a1<\/b><\/span>\n    <span>\u5206\u5e03\uff1a<b>\u5ba2\u9910\u538540 \/ \u4e3b\u536721 \/ \u6b21\u536710<\/b><\/span>\n    <span>\u65e5\u671f\uff1a<b>2026\u5e7409\u670813\u65e5<\/b><\/span>\n  <\/div>\n  <div class=\"brand\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u8bb8\u7ecf\u9500\u5546\u3000|\u3000\u95e8\u5e97\uff1a\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348 \u00b7 028-86131795<\/div>\n<\/header>\n\n<!-- \u4e00\u3001\u9700\u6c42\u8bca\u65ad -->\n<section id=\"s1\">\n  <div class=\"sec-h\"><span class=\"no\">\u4e00<\/span><h2>\u9700\u6c42\u8bca\u65ad\uff1a\u6211\u4eec\u8981\u89e3\u51b3\u4ec0\u4e48<\/h2><span class=\"tag\">\u4e3a\u4ec0\u4e48\u88c5\u5730\u6696<\/span><\/div>\n  <div class=\"infocard\">\n    <div class=\"row\"><span class=\"k\">\u91c7\u6696\u9762\u79ef<\/span><span>71\u33a1\uff08\u5ba2\u9910\u538540 \/ \u4e3b\u536721 \/ \u6b21\u536710\uff09<\/span><\/div>\n    <div class=\"row\"><span class=\"k\">\u7cfb\u7edf\u5f62\u5f0f<\/span><span>\u4f4e\u6e29\u70ed\u6c34\u5730\u9762\u8f90\u5c04\u4f9b\u6696\uff08\u6c34\u5730\u6696\uff09<\/span><\/div>\n    <div class=\"row\"><span class=\"k\">\u70ed\u6e90<\/span><span>\u71c3\u6c14\u58c1\u6302\u7089\uff08\u9505\u7089\uff09<\/span><\/div>\n    <div class=\"row\"><span class=\"k\">\u7ba1\u8def<\/span><span>\u4f1f\u661f\u5168\u5957\u7ba1\u8def\u7cfb\u7edf<\/span><\/div>\n    <div class=\"full row\"><span class=\"k\">\u6838\u5fc3\u8bc9\u6c42<\/span><span>\u5347\u6e29\u5747\u5300\u3001\u811a\u611f\u8212\u9002\u3001\u957f\u671f\u7701\u6c14\u3001\u7a33\u5b9a\u4e0d\u6545\u969c<\/span><\/div>\n  <\/div>\n  <div class=\"callout\">\n    <div class=\"ttl\">\u4e00\u53e5\u8bdd\u8bfb\u61c2\u9700\u6c42<\/div>\n    \u674e\u5973\u58eb\u8981\u7684\u4e0d\u53ea\u662f\"\u94fa\u4e00\u5708\u7ba1\u5b50\"\uff0c\u800c\u662f\u4e00\u5957<b>\u51ac\u5929\u811a\u6696\u3001\u8d39\u7528\u53ef\u63a7\u3001\u5341\u5e74\u4e0d\u51fa\u95ee\u9898<\/b>\u7684\u5730\u6696\u7cfb\u7edf\u3002\u8fd9\u6070\u6070\u662f\"\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\"\u4e0e\"\u5916\u9762\u901a\u914d\u7cfb\u7edf\"\u62c9\u5f00\u5dee\u8ddd\u7684\u5730\u65b9\u2014\u2014<b>\u540c\u6837\u7684\u7ba1\u5b50\uff0c\u88c5\u6cd5\u4e0d\u540c\uff0c\u6548\u679c\u548c\u71c3\u6c14\u8d39\u80fd\u5dee 30%\u201350%\u3002<\/b>\n  <\/div>\n  <h3 class=\"st\">\u6309\u56fd\u6807\u9010\u623f\u8ba1\u7b97\u70ed\u8d1f\u8377\uff08GB 50736-2012\uff0c\u7981\u4f30\u7b97\uff09<\/h3>\n  <table class=\"tbl\">\n    <thead><tr><th>\u533a\u57df<\/th><th>\u9762\u79ef\u33a1<\/th><th>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/th><th>\u6240\u9700\u70ed\u91cf<\/th><th>\u76d8\u7ba1\u95f4\u8ddd\u5efa\u8bae<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u5ba2\u9910\u5385<\/td><td>40<\/td><td>\u7ea6 100 W\/\u33a1<\/td><td>\u22484,000 W<\/td><td>15\u201320 cm<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>21<\/td><td>\u7ea6 100 W\/\u33a1<\/td><td>\u22482,100 W<\/td><td>15\u201320 cm\uff08\u9760\u5916\u5899 10\u201315\uff09<\/td><\/tr>\n      <tr><td>\u6b21\u5367<\/td><td>10<\/td><td>\u7ea6 100 W\/\u33a1<\/td><td>\u22481,000 W<\/td><td>15\u201320 cm<\/td><\/tr>\n      <tr style=\"background:#f7f3e9\"><td colspan=\"5\" style=\"color:var(--gold-2)\"><b>\u5168\u5c4b\u603b\u70ed\u8d1f\u8377 \u2248 7.1 kW<\/b> \u2014\u2014 \u8fd9\u662f\u9505\u7089\u9009\u578b\u7684\u57fa\u51c6\uff0c\u800c\u975e\"\u8d8a\u5927\u8d8a\u6696\"\u3002<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/section>\n\n<!-- \u4e8c\u3001\u56db\u8981\u7d20 -->\n<section id=\"s2\">\n  <div class=\"sec-h\"><span class=\"no\">\u4e8c<\/span><h2>\u4e13\u4e1a\u5730\u6696\u7684\u7cfb\u7edf\u89c2\uff1a\u56db\u5927\u8981\u7d20\u7f3a\u4e00\u4e0d\u53ef<\/h2><span class=\"tag\">\u65b9\u6cd5\u8bba<\/span><\/div>\n  <div class=\"callout\">\n    \u5730\u6696\u4e0d\u662f\"\u4e00\u53f0\u9505\u7089 + \u4e00\u76d8\u7ba1\u5b50\"\uff0c\u800c\u662f <b>\u70ed\u6e90 \u2192 \u8f93\u914d \u2192 \u672b\u7aef \u2192 \u63a7\u5236<\/b> \u56db\u4e2a\u73af\u8282\u7684\u534f\u540c\u7cfb\u7edf\u3002\u4efb\u4e00\u73af\u8282\u4e0d\u5339\u914d\uff0c\u5c31\u4f1a\"\u4ea7\u7684\u70ed\u62c9\u4e0d\u8d70\u3001\u62c9\u6765\u7684\u70ed\u6563\u4e0d\u6389\"\uff0c\u7ed3\u679c\u5c31\u662f<b>\u4e0d\u70ed + \u8d39\u6c14<\/b>\u3002\n  <\/div>\n  <div class=\"flow4\" id=\"flow4\">\n    <p style=\"font-size:12.5px;color:var(--txt-dim);margin:0 0 20px\">\u8fdb\u5ea6\u6761\u5c06\u4f9d\u6b21\u63a8\u8fdb\u56db\u4e2a\u8981\u7d20\uff0c\u6bcf\u5230\u4e00\u4e2a\u8282\u70b9\u81ea\u52a8\u5c55\u793a\u8be5\u8981\u7d20\u7684\u8be6\u60c5\uff1b\u4e5f\u53ef\u76f4\u63a5\u70b9\u51fb\u8282\u70b9\u67e5\u770b\u3002<\/p>\n    <div class=\"flow4-line\">\n      <div class=\"flow4-fill\"><\/div>\n      <div class=\"flow4-node\" data-i=\"0\"><span class=\"ic\">\ud83d\udd25<\/span><span class=\"nm\">\u2460 \u70ed\u6e90<\/span><\/div>\n      <div class=\"flow4-node\" data-i=\"1\"><span class=\"ic\">\ud83d\udd27<\/span><span class=\"nm\">\u2461 \u8f93\u914d<\/span><\/div>\n      <div class=\"flow4-node\" data-i=\"2\"><span class=\"ic\">\u2668\ufe0f<\/span><span class=\"nm\">\u2462 \u672b\u7aef<\/span><\/div>\n      <div class=\"flow4-node\" data-i=\"3\"><span class=\"ic\">\ud83c\udf9b\ufe0f<\/span><span class=\"nm\">\u2463 \u63a7\u5236<\/span><\/div>\n    <\/div>\n    <div class=\"flow4-detail\"><\/div>\n  <\/div>\n  <div class=\"grid2\">\n    <div class=\"card\"><div class=\"ct\">\u5224\u65ad\u6807\u51c6<\/div><ul>\n      <li>\u56db\u8981\u7d20\u5168\u90e8\u5339\u914d = <b>\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf<\/b><\/li>\n      <li>\u91cd\u8bbe\u5907\u3001\u8f7b\u5339\u914d = \u901a\u914d\u7cfb\u7edf<\/li><\/ul><\/div>\n    <div class=\"card\"><div class=\"ct\">\u5e26\u6765\u7684\u7ed3\u679c<\/div><ul>\n      <li>\u5404\u623f\u95f4\u6e29\u5dee \u00b13\u2103 \u2192 <b>\u00b11\u2103<\/b><\/li>\n      <li>\u9505\u7089\u542f\u505c\u6b21\u6570\u51cf\u5c11 <b>70%+<\/b><\/li>\n      <li>\u8fd0\u884c\u8d39\u6bd4\u4e00\u822c\u65b9\u6848<b>\u7701 20%\u201330%<\/b><\/li><\/ul><\/div>\n  <\/div>\n<\/section>\n\n<!-- \u4e09\u3001\u4e13\u4e1a vs \u901a\u914d -->\n<section id=\"s3\">\n  <div class=\"sec-h\"><span class=\"no\">\u4e09<\/span><h2>\u4e13\u4e1a\u6280\u80fd\u8bbe\u8ba1 vs \u5916\u9762\u901a\u914d\u7cfb\u7edf<\/h2><span class=\"tag\">\u6838\u5fc3\u5dee\u5f02<\/span><\/div>\n  <div class=\"callout\" style=\"border-color:var(--gold-dim)\">\n    \u8fd9\u662f\u672c\u65b9\u6848\u6700\u60f3\u8ba9\u60a8\u770b\u6e05\u7684\u4e00\u5f20\u8868\uff1a<b>\u4e3a\u4ec0\u4e48\"\u4fbf\u5b9c\u7684\u5730\u6696\"\u5f80\u5f80\u6700\u540e\u66f4\u8d35<\/b>\u3002\n  <\/div>\n  <table class=\"tbl\">\n    <thead><tr><th style=\"width:16%\">\u7ef4\u5ea6<\/th><th style=\"width:42%\">\u5916\u9762\u901a\u914d\u7cfb\u7edf\uff08\u5e38\u89c1\u505a\u6cd5\uff09<\/th><th>\u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u9505\u7089\u529f\u7387<\/td><td class=\"bad\">\u76f2\u76ee 24\/28kW \u8d85\u914d\uff0c\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\uff0c\u9891\u7e41\u542f\u505c\u3001\u80fd\u8017\u98d9\u5347<\/td><td class=\"good\">\u6309 7.1kW \u9700\u6c42\u5339\u914d\uff0c\u6821\u6838\u6700\u5c0f\u529f\u7387\uff0c\u8fde\u7eed\u7a33\u5b9a\u8fd0\u884c<\/td><\/tr>\n      <tr><td>\u7ba1\u8def\u5f62\u5f0f<\/td><td class=\"bad\">\u53cc\u7ba1\u5f02\u7a0b\uff0c\u6c34\u8d70\u8fd1\u8def \u2192 \u8fd1\u7aef\u70ed\u3001\u8fdc\u7aef\u51b7<\/td><td class=\"good\">\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f\uff0c\u5404\u652f\u8def\u7b49\u957f\uff0c\u6c34\u529b\u5e73\u8861<\/td><\/tr>\n      <tr><td>\u4e3b\u7ba1\u7ba1\u5f84<\/td><td class=\"bad\">De25\uff0824kW \u5b9e\u9645\u6d41\u91cf\u4ec5\u7ea6 900L\/h\uff0c\u4e25\u91cd\u4e0d\u8db3\uff09<\/td><td class=\"good\">\u4e3b\u7ba1 De32 \u8d77\uff0c\u6d41\u91cf\u5145\u8db3\u3001\u70ed\u91cf\u62c9\u5f97\u8d70<\/td><\/tr>\n      <tr><td>\u7ba1\u6750<\/td><td class=\"bad\">\u666e\u901a PERT \u7ba1\uff0c\u65e0\u963b\u6c27\u5c42 \u2192 \u6c27\u5316\u9ed1\u6c34\u3001\u7ed3\u57a2\u3001\u6548\u7387\u9010\u5e74\u964d<\/td><td class=\"good\">\u4f1f\u661f\u963b\u6c27\u7ba1\u8def\uff08EVOH \u963b\u6c27\u5c42\uff09\uff0c\u7cfb\u7edf\u957f\u5e74\u6e05\u51c0<\/td><\/tr>\n      <tr><td>\u4fdd\u6e29<\/td><td class=\"bad\">\u52a3\u8d28\u8584\u677f\uff0c\u5411\u4e0b\u70ed\u635f\u5931 &gt;30%<\/td><td class=\"good\">\u4f1f\u661f XPS\/\u767d\u6676\u4fdd\u6e29\u677f + <b>\u5168\u94dd<\/b>\u53cd\u5c04\u819c\uff0c\u8fb9\u89d2\u4fdd\u6e29\u6761<\/td><\/tr>\n      <tr><td>\u6c34\u529b\u5e73\u8861<\/td><td class=\"bad\">\u65e0\u5e73\u8861\u63aa\u65bd\uff0c\u76f2\u76ee\u70e7<\/td><td class=\"good\">\u6bcf\u652f\u8def\u52a0\u5e73\u8861\u9600\/\u6d41\u91cf\u8ba1\uff0c\u5206\u96c6\u6c34\u5668\u5747\u8861\u5206\u914d<\/td><\/tr>\n      <tr><td>\u63a7\u5236\u903b\u8f91<\/td><td class=\"bad\">\u4ec5\u6c34\u6e29\u63a7\u5236\uff0c\u5ba4\u6e29\u8fbe\u6807\u9505\u7089\u4ecd\u5728\u70e7\uff08\u65e0\u6548\u4ea7\u70ed\uff09<\/td><td class=\"good\">\u5ba4\u6e29<b>\u8054\u52a8<\/b>\u63a7\u5236\uff1a\u8fbe\u6807\u5373\u505c\u3001\u6309\u9700\u4f9b\u70ed<\/td><\/tr>\n      <tr><td>\u672b\u7aef\u9002\u914d<\/td><td class=\"bad\">\u51b7\u51dd\u7089\u914d\u9ad8\u6e29\u672b\u7aef\uff0c\u8fdb\u4e0d\u4e86\u51b7\u51dd\u5de5\u51b5 = \u767d\u4e70<\/td><td class=\"good\">\u51b7\u51dd\u7089 + \u5730\u6696\u4f4e\u6e29\uff0835\u201345\u2103\uff09\uff0c\u9ad8\u6548\u533a\u8fd0\u884c<\/td><\/tr>\n      <tr><td>\u65bd\u5de5\u9a8c\u6536<\/td><td class=\"bad\">\u4e0d\u6253\u538b\u6216\u4e0d\u89c4\u8303\uff0c\u56de\u586b\u70d8\u5e72\u5f00\u88c2\uff0c\u9690\u853d\u65e0\u4fdd\u538b<\/td><td class=\"good\">\u6253\u538b 0.6MPa \u7a33 1h\u3001\u56de\u586b\u517b\u62a4\u22657\u5929\u3001\u62cd\u7167\u5b58\u6863<\/td><\/tr>\n      <tr><td>\u5e74\u80fd\u8017<\/td><td class=\"bad\">\u542f\u505c\u6076\u6027\u5faa\u73af\uff0c\u71c3\u6c14\u8d39\u6084\u6084\u591a\u82b1<\/td><td class=\"good\">\u8fde\u7eed\u8fd0\u884c\uff0c<b>\u7701\u6c14 20%\u201330% \u4ee5\u4e0a<\/b><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"trust\">\n    <b>\u5178\u578b\"\u901a\u914d\u5751\"\u5b9e\u4f8b\uff1a<\/b>\u5e02\u9762\u5e38\u89c1\"24kW \u7089 + De25 \u7ba1 + \u5f02\u7a0b + \u666e\u901a\u6696\u6c14\u7247\"\uff0c\u70ed\u91cf\u8fd0\u4e0d\u8d70\u3001\u6c34\u6e29\u88ab\u5806\u9ad8\u3001\u51b7\u51dd\u5931\u6548\u2014\u2014\u521d\u88c5\u4fbf\u5b9c\u51e0\u5343\uff0c\u4f46\u6bcf\u5e74\u591a\u70e7\u7684\u71c3\u6c14\u3001\u51e0\u5e74\u540e\u7684\u9ed1\u6c34\u548c\u6545\u969c\uff0c\u8fdc\u8d85\u5f53\u521d\u7701\u4e0b\u7684\u94b1\u3002\n  <\/div>\n<\/section>\n\n<!-- \u56db\u3001\u672b\u7aef\u8bbe\u8ba1 -->\n<section id=\"s4\">\n  <div class=\"sec-h\"><span class=\"no\">\u56db<\/span><h2>\u672b\u7aef\u8bbe\u8ba1\uff1a\u4f1f\u661f\u7ba1\u8def + \u4e13\u4e1a\u5de5\u827a<\/h2><span class=\"tag\">\u7528\u6599\u770b\u8fd9\u91cc<\/span><\/div>\n\n  <h3 class=\"st\">\u7ba1\u8def\u54c1\u724c\uff1a\u4f1f\u661f A+ \u7ba1\u9053\u7cfb\u7edf\uff08\u5168\u5957\uff09<\/h3>\n  <table class=\"tbl\">\n    <thead><tr><th>\u7279\u70b9<\/th><th>\u4f1f\u661f A+ \u7ba1<\/th><th>\u666e\u901a\u7ba1\u5bf9\u6bd4<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u6750\u6599<\/td><td>\u8fdb\u53e3 II \u578b PE-RT\uff08\u5229\u5b89\u5fb7\u5df4\u8d5b\u5c14\u539f\u6599\uff09<\/td><td>\u666e\u901a I \u578b PE-RT<\/td><\/tr>\n      <tr><td>\u8bbe\u8ba1\u5bff\u547d<\/td><td class=\"good\">75 \u5e74<\/td><td>\u7ea6 50 \u5e74<\/td><\/tr>\n      <tr><td>\u8010\u6e29\u8303\u56f4<\/td><td class=\"good\">-20\u2103 ~ 95\u2103<\/td><td>\u7ea6 \u226470\u2103<\/td><\/tr>\n      <tr><td>\u901a\u6d41\u80fd\u529b<\/td><td class=\"good\">\u6bd4\u666e\u901a\u5851\u6599\u7ba1\u9ad8 36% \u4ee5\u4e0a<\/td><td>\u57fa\u51c6<\/td><\/tr>\n      <tr><td>\u536b\u751f\/\u73af\u4fdd<\/td><td>62 \u94dc\u5d4c\u4ef6\u3001\u65e0\u7535\u9540\u3001\u4e0d\u9508\u8680<\/td><td>\u7535\u9540\u4ef6\u6613\u6c61\u67d3<\/td><\/tr>\n      <tr><td>\u552e\u540e<\/td><td class=\"good\">\"\u661f\u7ba1\u5bb6\"\u4e0a\u95e8\u8bd5\u538b + \u8d28\u4fdd\u5361 + \u7ba1\u8def\u56fe\u5b58\u6863<\/td><td>\u591a\u6570\u65e0<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <h3 class=\"st\">\u8bbe\u8ba1\u53c2\u6570\uff08\u6309 JGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b\uff09<\/h3>\n  <table class=\"tbl\">\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u6807\u51c6\u53d6\u503c<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u76d8\u7ba1\u95f4\u8ddd<\/td><td>\u5e38\u89c4\u533a 15\u201320cm\uff1b\u9760\u5916\u5899\/\u536b\u751f\u95f4 10\u201315cm\uff1b\u8ddd\u5899 \u2265100mm<\/td><\/tr>\n      <tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>\u226460\u2103\uff0c\u4f4e\u6e29\u9ad8\u6548\u8fd0\u884c 35\u201345\u2103\uff08\u4f9b\u56de\u6c34\u6e29\u5dee 8\u201310\u2103\uff09<\/td><\/tr>\n      <tr><td>\u5730\u9762\u6e29\u5ea6<\/td><td>\u226429\u2103\uff08\u957f\u671f\u505c\u7559\u533a\uff09\uff0c\u8212\u9002 24\u201326\u2103\uff1b\u5ba4\u6e29 18\u201322\u2103<\/td><\/tr>\n      <tr><td>\u5355\u56de\u8def\u957f\u5ea6<\/td><td>De16 \u2264120m \/ De20 \u2264150m\uff0c\u8986\u76d6\u7ea6 12\u201318\u33a1<\/td><\/tr>\n      <tr><td>\u94fa\u8bbe\u5f62\u5f0f<\/td><td>\u56de\u5b57\u5f62\uff08\u4f18\u4e8e S \u5f62\uff09\uff0c\u5e03\u7ba1\u5747\u5300<\/td><\/tr>\n      <tr><td>\u4fdd\u6e29\u5c42<\/td><td>\u4f1f\u661f XPS\/\u767d\u6676\u677f + \u5168\u94dd\u53cd\u5c04\u819c + \u8fb9\u89d2\u4fdd\u6e29\u6761\uff0c\u56de\u586b<b>\u6309 40\u201350mm<\/b> \u84c4\u70ed\u5c42\u8bbe\u8ba1\uff08\u8c46\u77f3\u6df7\u51dd\u571f C15\uff0c\u6700\u4f4e \u226530mm\uff09\u2014\u2014\u84c4\u70ed\u5c42\u540c\u65f6\u662f\u542f\u505c\u7f13\u51b2<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"callout\">\n    <div class=\"ttl\">\u7ba1\u8def\u5e03\u7f6e\u793a\u610f\uff08\u7ae0\u9c7c\u5f0f \/ \u540c\u7a0b\uff09<\/div>\n    \u5206\u96c6\u6c34\u5668\u96c6\u4e2d\u5206\u914d \u2192 \u5404\u623f\u95f4\u72ec\u7acb\u56de\u8def\u3001\u7ba1\u957f\u76f8\u7b49 \u2192 \u914d\u5408\u6bcf\u652f\u8def\u5e73\u8861\u9600\uff0c\u5b9e\u73b0<b>\u5168\u5c4b\u6e29\u5dee \u00b11\u2103<\/b>\u3002\u8fd9\u662f\"\u8fd1\u7aef\u70ed\u8fdc\u7aef\u51b7\"\u7684\u901a\u914d\u505a\u6cd5\u505a\u4e0d\u5230\u7684\u3002\n  <\/div>\n<\/section>\n\n<!-- \u4e94\u3001\u70ed\u6e90\u9009\u578b -->\n<section id=\"s5\">\n  <div class=\"sec-h\"><span class=\"no\">\u4e94<\/span><h2>\u70ed\u6e90\u9009\u578b\uff1a\u9505\u7089\u5230\u5e95\u600e\u4e48\u9009<\/h2><span class=\"tag\">\u5173\u952e\u51b3\u7b56<\/span><\/div>\n  <div class=\"callout\">\n    \u8fd9\u662f\u674e\u5973\u58eb\u6700\u5173\u5fc3\u7684\u95ee\u9898\u3002\u9009\u9505\u7089\u4e0d\u662f\"\u8d8a\u8d35\u8d8a\u597d\u3001\u8d8a\u5927\u8d8a\u6696\"\uff0c\u800c\u662f\u770b<b>\u4e09\u4e2a\u5339\u914d<\/b>\uff1a\u6700\u5927\u529f\u7387\u5339\u914d\u3001\u6700\u5c0f\u529f\u7387\u5339\u914d\u3001\u4e0d\u8d85\u914d\u3002\n  <\/div>\n\n  <h3 class=\"st\">\u2460 \u5148\u7b97\u529f\u7387\uff0871\u33a1 \u4e3a\u4f8b\uff09<\/h3>\n  <div class=\"callout\" style=\"border-color:var(--gold-dim)\">\n    \u70ed\u6e90\u529f\u7387(kW) \uff1d \u91c7\u6696\u9762\u79ef(\u33a1) \u00d7 \u8bbe\u8ba1\u70ed\u8d1f\u8377(W\/\u33a1) \u00f7 1000 \u00d7 \u5b89\u5168\u7cfb\u6570(1.1\u20131.2)<br>\n    \uff1d 71 \u00d7 100 \u00f7 1000 \u00d7 1.15 \u2248 <b>8.2 kW<\/b>\uff08\u91c7\u6696\u5b9e\u9645\u9700\u6c42\uff09<br>\n    \u2014\u2014 \u56e0\u6b64\uff1a<b>\u91c7\u6696\u7528\u9014 \u2264100\u33a1\uff0c\u9009 18\u201324kW \u5373\u53ef<\/b>\uff1b<span style=\"color:var(--warn)\">\u4e25\u7981\u4e3a\u70ed\u6c34\u76f2\u76ee\u9009 28kW \u4ee5\u4e0a<\/span>\u3002\n  <\/div>\n\n  <h3 class=\"st\">\u2461 \u51b7\u51dd\u7089 vs \u5e38\u89c4\u7089\uff08\u6280\u672f\u672c\u8d28\u533a\u522b\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--txt-dim);margin:0 0 6px\">\u4e0b\u56fe\u4e3a\u4e24\u5927\u7089\u578b\u5728 7 \u9879\u6280\u672f\u6307\u6807\u4e0a\u7684\u76f8\u5bf9\u8868\u73b0\uff08\u8d8a\u9760\u5916\u8d8a\u4f18\uff0c0\u2013100 \u4e3a\u53ef\u89c6\u5316\u8bc4\u5206\uff09\u3002\u5224\u5e9f\u5e74\u9650\u672a\u5165\u56fe\uff1a\u56fd\u6807\u5224\u5e9f\u5e74\u9650\u4e24\u8005\u540c\u4e3a 8 \u5e74\uff08GB 17905-2008\uff09\uff0c\u800c\u5b9e\u9645\u4f7f\u7528\u5bff\u547d\u5e38\u89c4\u7089\u7ea6 8\u201310 \u5e74\u3001\u51b7\u51dd\u7089\u7ea6 10\u201315 \u5e74\u3002<\/p>\n  <div class=\"radar-box\">\n    <div id=\"radarVs\" class=\"radar-canvas\"><\/div>\n    <div class=\"radar-legend\"><span><i class=\"dot a\"><\/i>\u5e38\u89c4\u7089<\/span><span><i class=\"dot b\"><\/i>\u51b7\u51dd\u7089<\/span><\/div>\n  <\/div>\n  <div class=\"radar-notes\">\n    <div class=\"rn-col\"><div class=\"rn-tt\">\u5e38\u89c4\u7089<\/div><ul>\n      <li>\u521d\u6295\u8d44\u8f83\u4f4e\u3001\u7ed3\u6784\u7b80\u5355<\/li>\n      <li>\u771f\u5b9e\u70ed\u6548\u7387 80\u201384%\uff0c\u6392\u70df\u6e29\u5ea6\u9ad8\u3001\u65e0\u6cd5\u56de\u6536\u6c7d\u5316\u6f5c\u70ed<\/li>\n      <li>\u6700\u5c0f\u8f93\u51fa 8\u201310kW\uff0c\u5c0f\u9762\u79ef\u6613\u9891\u7e41\u542f\u505c<\/li>\n      <li>\u94dc\u6362\u70ed\u5668\uff0c\u56de\u6c34 &lt;60\u2103 \u6613\u4ea7\u9178\u8150\u8680<\/li>\n    <\/ul><\/div>\n    <div class=\"rn-col\"><div class=\"rn-tt\">\u51b7\u51dd\u7089<\/div><ul>\n      <li>\u5168\u9884\u6df7\uff0c\u56de\u6536\u6c7d\u5316\u6f5c\u70ed\uff0c\u771f\u5b9e\u70ed\u6548\u7387 93\u201397%<\/li>\n      <li>\u6392\u70df 30\u201350\u2103\uff08\u9732\u70b9\u4ee5\u4e0b\uff09\uff0c\u6700\u5c0f\u8f93\u51fa 3\u20134kW \u8fde\u7eed\u7a33\u5b9a<\/li>\n      <li>\u4e0d\u9508\u94a2\/\u7845\u94dd\u6362\u70ed\u5668\uff0c\u8010\u9178\u8150\u8680<\/li>\n      <li>\u9002\u914d\u5730\u6696\u4f4e\u6e29\uff08\u226450\u2103\uff09\u9ad8\u6548\u8fd0\u884c\uff1b\u521d\u6295\u8d44\u7ea6\u9ad8\u4e00\u500d<\/li>\n    <\/ul><\/div>\n  <\/div>\n  <div class=\"trust\">\n    <b>\u4e24\u4e2a\u5fc5\u987b\u63d0\u9192\u7684\"\u5751\"\uff1a<\/b><br>\n    \u26a0\ufe0f <b>\u51b7\u51dd\u7089\u914d\u9519\u672b\u7aef = \u767d\u4e70<\/b>\uff1a\u82e5\u914d\u9700 70\u201380\u2103 \u7684\u666e\u901a\u6696\u6c14\u7247\uff0c\u8fdb\u4e0d\u4e86\u51b7\u51dd\u5de5\u51b5\uff0c\u6548\u7387\u53ea\u6bd4\u5e38\u89c4\u7089\u9ad8 3\u20135%\u3002\u88c5\u5730\u6696\u624d\u662f\u5b83\u7684\u4e3b\u573a\u3002<br>\n    \u26a0\ufe0f <b>\u4e24\u7528\u7089\"\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\"\u7684\u89e3\u6cd5<\/b>\uff1a\u666e\u901a\u4e24\u7528\u7089\u5728\u751f\u6d3b\u70ed\u6c34\u5c0f\u6d41\u91cf\u65f6\u5bb9\u6613\u5ffd\u51b7\u5ffd\u70ed\u3002<b>\u89e3\u6cd5\u662f\"\u53d8\u9891\u5206\u6bb5\u71c3\u70e7\u7089\"<\/b>\u2014\u2014\u901a\u8fc7\u5206\u6bb5\u706b\u529b\u7cbe\u51c6\u5339\u914d\u6240\u9700\u70ed\u8d1f\u8377\uff0c\u751f\u6d3b\u70ed\u6c34\u5168\u7a0b\u6052\u6e29\uff08\u51ac\u4e0d\u51c9\u590f\u4e0d\u70eb\uff09\u3002\u8fd9\u6b63\u662f\u672c\u6848\u9009\u7528\u5b83\u7684\u539f\u56e0\u4e4b\u4e00\u3002\n  <\/div>\n\n  <h3 class=\"st\">\u2462 \u672c\u6848\u9505\u7089\u9009\u578b\uff1a\u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089\uff08\u63a8\u8350\uff09<\/h3>\n  <p style=\"font-size:13px;color:var(--txt-dim);margin:0 0 6px\">\u4e24\u5f20\u5361\u724c\u6a2a\u6392\u5c55\u793a\uff0c<b>\u70b9\u51fb\u5361\u724c\u53ef\u7ffb\u8f6c<\/b>\u2014\u2014\u6b63\u9762\u4e3a\u65b9\u6848\u9009\u578b\u4e0e\u4ea7\u54c1\u56fe\uff0c\u80cc\u9762\u4e3a\u65b9\u6848\u7279\u70b9\u4e0e\u4ef7\u683c\uff08\u542b\u5b89\u88c5\uff09\u3002<\/p>\n  <div class=\"flip-wrap\">\n    <div class=\"flip-card\">\n      <div class=\"flip-inner\">\n        <div class=\"flip-face flip-front\">\n          <span class=\"flip-badge flip-rec\">A \u00b7 \u9996\u9009\u63a8\u8350<\/span>\n          <div class=\"flip-name\">\u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089<\/div>\n          <div class=\"flip-sub\">\u66fc\u745e\u5fb7 L1PB26-Heidelberg Min.\uff0824kW\uff09<\/div>\n          <figure class=\"prod-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\" alt=\"\u66fc\u745e\u5fb7 \u6d77\u5fb7\u5821\u53d8\u9891\u5206\u6bb5\u4e24\u7528\u7089 L1PB24-Heidelberg\" loading=\"lazy\"><\/figure>\n          <div class=\"flip-hint\">\u70b9\u51fb\u5361\u724c\u67e5\u770b \u7279\u70b9\u4e0e\u4ef7\u683c \u2192<\/div>\n        <\/div>\n        <div class=\"flip-face flip-back\">\n          <div class=\"flip-back-ttl\">A \u00b7 \u65b9\u6848\u7279\u70b9\u4e0e\u4ef7\u683c<\/div>\n          <ul class=\"flip-list\">\n            <li><b>\u5206\u6bb5\u71c3\u70e7<\/b>\u51fa\u6c34\uff0c\u751f\u6d3b\u70ed\u6c34\u6052\u6e29\u7a33\u5b9a\uff0c\u89e3\u51b3\"\u5ffd\u51b7\u5ffd\u70ed\"<\/li>\n            <li>\u6700\u5c0f\u4f9b\u6696\u8f93\u51fa 8.5kW\uff0c\u4e0e 71\u33a1 \u7684 7.1kW \u8d1f\u8377\u63a5\u8fd1\u2014\u2014<b>\u6700\u5c0f\u8f93\u51fa\u8d8a\u8d34\u8fd1\u6ee1\u8d1f\u8377\u9700\u6c42\uff0c\u90e8\u5206\u8d1f\u8377\u65f6\u6bb5\u8d8a\u5bb9\u6613\u542f\u505c<\/b>\uff1b\u9f99\u8109\u7528 <b>40\u201350mm \u84c4\u70ed\u56de\u586b\u5c42 + \u5206\u5ba4\u6e29\u63a7 + \u6c14\u5019\u8865\u507f<\/b> \u62c9\u957f\u542f\u505c\u95f4\u9694\u3001\u628a\u5f71\u54cd\u964d\u5230\u6700\u4f4e<\/li>\n            <li>\u6295\u5165\u4f4e\uff0c\u914d\u5408\u6c34\u529b\u5e73\u8861 + \u5ba4\u6e29\u8054\u52a8 + \u6c14\u5019\u8865\u507f\u7684\u4e13\u4e1a\u8bbe\u8ba1\uff0c\u80fd\u6548\u63a5\u8fd1\u51b7\u51dd\u6548\u679c<\/li>\n          <\/ul>\n          <div class=\"flip-price\">5,599 + 600 = <b>6,199 \u5143<\/b><span>\uff08\u542b\u5b89\u88c5\uff09<\/span><\/div>\n          <div class=\"flip-hint\">\u2190 \u70b9\u51fb\u8fd4\u56de<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <div class=\"flip-card\">\n      <div class=\"flip-inner\">\n        <div class=\"flip-face flip-front\">\n          <span class=\"flip-badge flip-alt\">B \u00b7 \u5907\u9009<\/span>\n          <div class=\"flip-name\">\u5168\u9884\u6df7\u51b7\u51dd\u7089<\/div>\n          <div class=\"flip-sub\">\u66fc\u745e\u5fb7 \u5c0f\u5361 LL1GQ24\uff0824kW\uff09<\/div>\n          <figure class=\"prod-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E6%9B%BC%E7%91%9E%E5%BE%B7-%E5%B0%8F%E5%8D%A1%E5%85%A8%E9%A2%84%E6%B7%B7%E5%86%B7%E5%87%9D%E5%A3%81%E6%8C%82%E7%82%89LL1GQ2428-%E7%9F%BF%E7%9F%B3%E7%99%BD.png\" alt=\"\u66fc\u745e\u5fb7 \u5c0f\u5361\u5168\u9884\u6df7\u51b7\u51dd\u58c1\u6302\u7089 LL1GQ24\/28-\u77ff\u77f3\u767d\" loading=\"lazy\"><\/figure>\n          <div class=\"flip-hint\">\u70b9\u51fb\u5361\u724c\u67e5\u770b \u7279\u70b9\u4e0e\u4ef7\u683c \u2192<\/div>\n        <\/div>\n        <div class=\"flip-face flip-back\">\n          <div class=\"flip-back-ttl\">B \u00b7 \u65b9\u6848\u7279\u70b9\u4e0e\u4ef7\u683c<\/div>\n          <ul class=\"flip-list\">\n            <li><b>\u5168\u9884\u6df7\u51b7\u51dd<\/b>\uff0c\u53ef\u56de\u6536\u6c7d\u5316\u6f5c\u70ed\uff0c\u70ed\u6548\u7387\u66f4\u9ad8<\/li>\n            <li>\u6700\u5c0f\u8f93\u51fa <b>3\u20134kW<\/b>\uff0c\u53ef\u5168\u5b63\u8fde\u7eed\u9759\u97f3\u8fd0\u884c<\/li>\n            <li>\u4f46<b>\u521d\u6295\u7ea6\u9ad8\u4e00\u500d<\/b>\uff0c71\u33a1 \u5c0f\u9762\u79ef\u4e0b\u56de\u6536\u5468\u671f\u957f\uff08\u89c1\u4e0b\u65b9\u56de\u6536\u671f\u6d4b\u7b97\uff09<\/li>\n          <\/ul>\n          <div class=\"flip-price\">10,900 + 600 = <b>11,500 \u5143<\/b><span>\uff08\u542b\u5b89\u88c5\uff09<\/span><\/div>\n          <div class=\"flip-hint\">\u2190 \u70b9\u51fb\u8fd4\u56de<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n  <div class=\"callout\">\n    <div class=\"ttl\">\u6211\u4eec\u7684\u63a8\u8350\uff08\u672c\u6848\u6700\u4f18\uff09<\/div>\n    <b>\u9996\u9009\u65b9\u6848 A\uff1a\u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089 + \u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\u3002<\/b><br>\n    \u672c\u6848\u91c7\u6696\u9762\u79ef\u4ec5 71\u33a1\uff0c\u70ed\u91cf\u9700\u6c42\u5c0f\uff08\u22487.1kW\uff09\u3002\u51b7\u51dd\u7089\u867d\u7136\u70ed\u6548\u7387\u66f4\u9ad8\uff0c\u4f46<b>\u521d\u6295\u8d35\u7ea6 5,301 \u5143<\/b>\uff0c\u662f\u5426\u5212\u7b97\u8981\u770b\u56de\u6536\u671f\uff08\u89c1\u4e0b\u8868\uff09\u3002<br>\n    \u56e0\u6b64\u66f4\u4f18\u89e3\u662f <b>\u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089<\/b>\uff1a<br>\n    \u2022 <b>\u5206\u6bb5\u71c3\u70e7<\/b>\u8ba9\u751f\u6d3b\u70ed\u6c34\u6052\u6e29\u7a33\u5b9a\uff0c\u89e3\u51b3\"\u5ffd\u51b7\u5ffd\u70ed\"\uff1b<br>\n    \u2022 \u521d\u6295\u4f4e\uff0c\u518d\u52a0\u4e0a <b>\u6c34\u529b\u5e73\u8861 + \u5ba4\u6e29\u8054\u52a8 + \u6c14\u5019\u8865\u507f<\/b> \u7684\u4e13\u4e1a\u7cfb\u7edf\u8bbe\u8ba1\uff0c\u628a\u80fd\u6548\u62c9\u5230\u63a5\u8fd1\u51b7\u51dd\u6548\u679c\u3002<br>\n    <b>\u9700\u5982\u5b9e\u8bf4\u660e\uff088.5kW \u6700\u5c0f\u8f93\u51fa\uff09\uff1a<\/b>\u666e\u901a\u7089\u6700\u5c0f\u4f9b\u6696\u8f93\u51fa 8.5kW\uff0c\u4e0e 71\u33a1 \u7684 7.1kW \u8d1f\u8377\u63a5\u8fd1\u2014\u2014<b>\u6700\u5c0f\u8f93\u51fa\u8d8a\u8d34\u8fd1\u6ee1\u8d1f\u8377\u9700\u6c42\uff0c\u90e8\u5206\u8d1f\u8377\u65f6\u6bb5\u8d8a\u5bb9\u6613\u542f\u505c<\/b>\u3002\u9f99\u8109\u7528 <b>40\u201350mm \u84c4\u70ed\u56de\u586b\u5c42 + \u5206\u5ba4\u6e29\u63a7 + \u6c14\u5019\u8865\u507f<\/b> \u62c9\u957f\u542f\u505c\u95f4\u9694\u3001\u628a\u5f71\u54cd\u964d\u5230\u6700\u4f4e\uff1b\u82e5\u60a8\u8ffd\u6c42\u5168\u5b63\u8fde\u7eed\u9759\u97f3\u8fd0\u884c\uff0c\u53ef\u9009 <b>\u65b9\u6848 B\uff08\u51b7\u51dd\u7089\uff0c\u6700\u5c0f\u8f93\u51fa 3\u20134kW\uff0c\u53ef\u5b8c\u5168\u8fde\u7eed\u8fd0\u884c\uff09<\/b>\u3002<br>\n    <b>\u7efc\u5408\u521d\u6295\u4e0e\u957f\u671f\u8d39\u7528\uff0c\u65b9\u6848 A \u4e3a\u672c\u6848\u6700\u4f18\uff0c\u6bcf\u6708\u71c3\u6c14\u4f7f\u7528\u8d39\u7ea6 500\u2013600 \u5143\u3002<\/b>\n  <\/div>\n  <h3 class=\"st\">\u51b7\u51dd\u7089\u591a\u4e45\u80fd\u56de\u672c\uff1f\uff08\u56de\u6536\u671f\u6d4b\u7b97 \u00b7 71\u33a1\uff09<\/h3>\n  <table class=\"tbl\">\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u65b9\u6848 A \u00b7 \u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089<\/th><th>\u65b9\u6848 B \u00b7 \u5168\u9884\u6df7\u51b7\u51dd\u7089<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u521d\u88c5\u5408\u8ba1\uff08\u672b\u7aef + \u70ed\u6e90\uff09<\/td><td>18,198 \u5143<\/td><td>23,499 \u5143<\/td><\/tr>\n      <tr><td>\u521d\u6295\u5dee\u989d<\/td><td>\u57fa\u51c6<\/td><td>+ 5,301 \u5143<\/td><\/tr>\n      <tr><td>\u5e74\u71c3\u6c14\u8d39\uff08\u91c7\u6696\u5b63\u7ea6 90\u2013120 \u5929\uff09<\/td><td>\u7ea6 1,750\u20132,100 \u5143<\/td><td>\u7ea6 1,450\u20131,750 \u5143<\/td><\/tr>\n      <tr style=\"background:#f7f3e9\"><td>\u5e74\u7701\u6c14<\/td><td>\u57fa\u51c6<\/td><td>\u7ea6 280\u2013400 \u5143<\/td><\/tr>\n      <tr><td><b>\u9759\u6001\u56de\u6536\u671f<\/b><\/td><td>\u2014<\/td><td><b>\u7ea6 14\u201319 \u5e74<\/b><\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"callout\" style=\"border-color:var(--gold-dim);font-size:13px\">\n    <b>\u7ed3\u8bba\uff1a<\/b>\u56de\u6536\u671f 14\u201319 \u5e74\uff0c\u5df2\u8d85\u8fc7\u58c1\u6302\u7089\u7684\u56fd\u6807\u5224\u5e9f\u5e74\u9650\uff088 \u5e74\uff09\u4e0e\u5e38\u89c1\u5b9e\u9645\u4f7f\u7528\u5e74\u9650\u2014\u2014<b>71\u33a1 \u5c0f\u9762\u79ef\u4e0a\uff0c\u51b7\u51dd\u7089\u591a\u82b1\u7684\u521d\u6295\u5f88\u96be\u9760\u7701\u6c14\u6536\u56de<\/b>\uff0c\u6545\u672c\u6848\u9996\u9009\u65b9\u6848 A\u3002\u82e5\u60a8\u66f4\u770b\u91cd\u5168\u5b63\u8fde\u7eed\u9759\u97f3\u4e0e\u66f4\u957f\u5bff\u547d\uff0c\u65b9\u6848 B \u4ecd\u662f\u53ef\u9009\u9879\u3002\n  <\/div>\n<\/section>\n\n<!-- \u516d\u3001\u63a7\u5236\u7cfb\u7edf -->\n<section id=\"s6\">\n  <div class=\"sec-h\"><span class=\"no\">\u516d<\/span><h2>\u63a7\u5236\u7cfb\u7edf\uff1a\u8ba9\u6bcf\u4e00\u5206\u6c14\u90fd\u7528\u5728\u5200\u5203\u4e0a<\/h2><span class=\"tag\">\u7701\u5fc3\u7684\u5173\u952e<\/span><\/div>\n  <div class=\"grid3\">\n    <div class=\"card\"><div class=\"ct\">\u5206\u5ba4\u63a7\u6e29<\/div><ul><li>\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acb\u6e29\u63a7\u5668 + \u7535\u70ed\u6267\u884c\u5668<\/li><li>\u53ea\u70e7\u5728\u7528\u7684\u623f\u95f4\uff0c\u4e0d\u6d6a\u8d39<\/li><\/ul><\/div>\n    <div class=\"card\"><div class=\"ct\">\u5ba4\u6e29\u8054\u52a8<\/div><ul><li>\u6e29\u63a7\u5668 \u2192 \u6c34\u6cf5 \u2192 \u9505\u7089\u8054\u52a8<\/li><li>\u5ba4\u6e29\u8fbe\u6807\u5373\u505c\uff0c\u675c\u7edd\"\u65e0\u6548\u4ea7\u70ed\"<\/li><\/ul><\/div>\n    <div class=\"card\"><div class=\"ct\">\u6c14\u5019\u8865\u507f + \u8fdc\u7a0b<\/div><ul><li>\u968f\u5ba4\u5916\u6e29\u5ea6\u81ea\u52a8\u8c03\u6c34\u6e29<\/li><li>APP \u8fdc\u7a0b\u9884\u70ed\uff0c\u56de\u5bb6\u5373\u6696<\/li><\/ul><\/div>\n  <\/div>\n  <div class=\"trust\"><b>\u7701\u6c14\u539f\u7406\uff1a<\/b>\u6ca1\u6709\u8054\u52a8\u7684\u7cfb\u7edf\uff0c\"\u5ba4\u6e29\u5230\u4e86\u9505\u7089\u8fd8\u5728\u70e7\"\uff0c\u65e0\u6548\u4ea7\u70ed 10%\u201330%\uff1b\u914d\u7f6e\u8054\u52a8\u6a21\u5757\u540e\uff0c\u6309\u9700\u4f9b\u70ed\uff0c\u8fd9\u6b63\u662f\u4e13\u4e1a\u7cfb\u7edf\u4e0e\u901a\u914d\u7cfb\u7edf\u71c3\u6c14\u8d39\u5dee\u8ddd\u7684\u4e3b\u8981\u6765\u6e90\u4e4b\u4e00\u3002<\/div>\n<\/section>\n\n<!-- \u4e03\u3001\u62a5\u4ef7 -->\n<section id=\"s7\">\n  <div class=\"sec-h\"><span class=\"no\">\u4e03<\/span><h2>\u900f\u660e\u62a5\u4ef7<\/h2><span class=\"tag\">\u62a5\u4ef7\u5c42<\/span><\/div>\n  <div class=\"callout\" style=\"border-color:var(--gold-dim);font-size:13px\">\n    <b>\u62a5\u4ef7\u8bf4\u660e\uff1a<\/b>\u672c\u65b9\u6848\u4e66\u4e3a<b>\u6280\u672f\u6807<\/b>\uff0c\u4ef7\u683c\u6309\u95e8\u5e97\u73b0\u884c\u53e3\u5f84\u51fa\u5177\uff0c\u4f9b\u914d\u7f6e\u4e0e\u9884\u7b97\u53c2\u8003\uff1b<b>\u6700\u7ec8\u4ee5\u6b63\u5f0f\u5408\u540c\u9501\u4ef7\u5355\u4e3a\u51c6<\/b>\u3002\u5982\u6d89\u53ca\u6d3b\u52a8\u4f18\u60e0\uff0c\u4ee5\u7b7e\u8ba2\u5f53\u65f6\u653f\u7b56\u4e3a\u51c6\uff0c\u7ebf\u4e0b\u6c9f\u901a\u786e\u8ba4\u3002\n  <\/div>\n  <div class=\"total\">\n    <div class=\"ttl\">\u6295\u8d44\u4f30\u7b97\uff08\u5143\uff09<\/div>\n    <table>\n      <tr><td>\u5730\u6696\u672b\u7aef\u7cfb\u7edf \u00b7 \u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\uff08\u542b\u8bbe\u8ba1 \/ \u4f1f\u661f\u5168\u5957\u7ba1\u8def \/ \u4fdd\u6e29 \/ \u5206\u96c6\u6c34\u5668 \/ \u8f85\u6750 \/ \u65bd\u5de5\uff09<\/td><td>71\u33a1 \u00d7 169 = 11,999<\/td><\/tr>\n      <tr><td>\u70ed\u6e90 \u00b7 \u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089 \u66fc\u745e\u5fb7 L1PB26\uff0824kW\uff09\u542b\u5b89\u88c5<\/td><td>6,199<\/td><\/tr>\n      <tr><td><b>\u5408\u8ba1 \u00b7 \u63a8\u8350\u65b9\u6848\uff08\u5206\u6bb5\u71c3\u70e7\u666e\u901a\u7089\uff09<\/b><\/td><td><b>\u2248 18,198<\/b><\/td><\/tr>\n      <tr><td>\u5bf9\u6bd4\uff1a\u82e5\u9009\u51b7\u51dd\u7089 \u66fc\u745e\u5fb7\u5c0f\u5361 LL1GQ24\uff08\u542b\u5b89\u88c5\uff09<\/td><td>11,500\uff08\u5408\u8ba1 \u2248 23,499\uff09<\/td><\/tr>\n    <\/table>\n  <\/div>\n  <p style=\"font-size:12.5px;color:var(--txt-dim)\">\u203b \u6bcf\u6708\u71c3\u6c14\u4f7f\u7528\u8d39\u9884\u4f30\u7ea6 <b>500\u2013600 \u5143<\/b>\uff08\u751f\u6d3b\u70ed\u6c34\u53e6\u8ba1\uff09\u3002\u542b\u63a7\u5236\u7cfb\u7edf\u53ca\u65bd\u5de5\uff1b\u4e0d\u542b\u71c3\u6c14\u7ba1\u6539\u9020\u3001\u7535\u6e90\u3001\u5730\u9762\u627e\u5e73\u7b49\u571f\u5efa\u9879\uff0c\u5177\u4f53\u4ee5\u5408\u540c\u6e05\u5355\u4e3a\u51c6\u3002\u9505\u7089\u578b\u53f7\u4e0e\u4ef7\u683c\u53d6\u81ea\u6307\u4ee42 \u4ea7\u54c1\u4ef7\u683c\u5e93\uff08\u5355\u4ef7\u4f53\u7cfb\uff0c\u4e0d\u6253\u6298\uff09\u3002<\/p>\n<\/section>\n\n<!-- \u516b\u3001\u65bd\u5de5\u4e0e\u9a8c\u6536 + 20\u5e74\u603b\u8d26 -->\n<section id=\"s8\">\n  <div class=\"sec-h\"><span class=\"no\">\u516b<\/span><h2>\u65bd\u5de5\u6807\u51c6\u4e0e 20 \u5e74\u8d26<\/h2><span class=\"tag\">\u4e3a\u4ec0\u4e48\u503c<\/span><\/div>\n\n  <h3 class=\"st\">\u7cbe\u5de5\u516d\u6b65\u6cd5 + 2 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u5168\u6d41\u7a0b<\/h3>\n  <p style=\"font-size:13px;color:var(--txt-dim);margin:0 0 6px\">36 \u9879\u9a8c\u6536\u6807\u51c6\u3001\u6807\u51c6\u5316\u65bd\u5de5\u3001\u6b65\u6b65\u7559\u5f71\u53ef\u8ffd\u6eaf\u2014\u2014<b>\u9690\u853d\u5de5\u7a0b\u53ef\u89c6\u5316<\/b>\uff0c\u8fd9\u662f\u9f99\u8109\u6696\u901a\u7684\u65bd\u5de5\u4ea4\u4ed8\u6807\u51c6\u3002<\/p>\n  <div class=\"ppt\" id=\"projPpt\">\n    <div class=\"ppt-stage\">\n      <div class=\"ppt-slide is-active\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">01<\/span><span class=\"ppt-title\">\u73b0\u573a\u52d8\u6d4b<\/span><\/div>\n        <div class=\"ppt-imgs i1\"><figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E5%AE%9A%E4%BD%8D1-1-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u73b0\u573a\u52d8\u6d4b \u00b7 \u5730\u6696\u5b9a\u4f4d\" loading=\"lazy\"><figcaption>\u73b0\u573a\u52d8\u6d4b \u00b7 \u5730\u6696\u5b9a\u4f4d<\/figcaption><\/figure><\/div>\n        <div class=\"ppt-desc\">\u8bbe\u8ba1\u5e08\u4e0a\u95e8\u52d8\u6d4b\u6237\u578b\u7ed3\u6784\u3001\u5c42\u9ad8\u3001\u5730\u9762\u5e73\u6574\u5ea6\u4e0e\u5206\u96c6\u6c34\u5668\u6700\u4f73\u4f4d\u7f6e\uff0c\u7cbe\u786e\u6d4b\u91cf\u91c7\u6696\u9762\u79ef\u3001\u8bb0\u5f55\u7279\u6b8a\u9700\u6c42\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">02<\/span><span class=\"ppt-title\">\u7cfb\u7edf\u8bbe\u8ba1<\/span><\/div>\n        <div class=\"ppt-imgs i1\"><figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E8%AE%BE%E8%AE%A1%E5%9B%BE%E5%91%A8%E8%80%81%E5%B8%88-1024x724.png\" width=\"1024\" height=\"724\" alt=\"\u5730\u6696\u76d8\u7ba1\u8bbe\u8ba1\u56fe \u00b7 \u56de\u8def\u95f4\u8ddd\u6807\u6ce8\" loading=\"lazy\"><figcaption>\u5730\u6696\u76d8\u7ba1\u8bbe\u8ba1\u56fe \u00b7 \u56de\u8def\u95f4\u8ddd\u6807\u6ce8<\/figcaption><\/figure><\/div>\n        <div class=\"ppt-desc\">\u6309\u52d8\u6d4b\u6570\u636e\u8ba1\u7b97\u70ed\u8d1f\u8377\uff0c\u7ed8\u5236\u76d8\u7ba1\u5e03\u7f6e\u56fe\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u56fe\uff0c<b>\u7ecf\u5ba2\u6237\u786e\u8ba4<\/b>\u540e\u4f5c\u4e3a\u65bd\u5de5\u4f9d\u636e\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">03<\/span><span class=\"ppt-title\">\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/span><\/div>\n        <div class=\"ppt-desc\">\u6240\u6709\u7ba1\u6750\u3001\u4fdd\u6e29\u677f\u3001\u5206\u96c6\u6c34\u5668\u7b49\u6750\u6599\u8fdb\u573a\u65f6\uff0c<b>\u4e0e\u5ba2\u6237\u5171\u540c\u9a8c\u6536<\/b>\u54c1\u724c\u578b\u53f7\u89c4\u683c\uff0c\u786e\u8ba4\u65e0\u8bef\u540e\u65b9\u53ef\u65bd\u5de5\u3002<br>\u9a8c\u6536\u8981\u70b9\uff1a\u6838\u5bf9\u54c1\u724c\u578b\u53f7\u89c4\u683c \u2192 \u68c0\u67e5\u7ba1\u6750\u55b7\u7801\u6279\u6b21 \u2192 \u4fdd\u6e29\u677f\u539a\u5ea6\u5bc6\u5ea6 \u2192 \u5206\u96c6\u6c34\u5668\u6750\u8d28\u5de5\u827a \u2192 \u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">04<\/span><span class=\"ppt-title\">\u7cfb\u7edf\u5b89\u88c5 \u00b7 \u5730\u6696\u94fa\u8bbe<\/span><\/div>\n        <div class=\"ppt-imgs i6\">\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-jsbps-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u6324\u5851\u677f\u94fa\u8bbe\" loading=\"lazy\"><figcaption>\u6324\u5851\u677f\u94fa\u8bbe<\/figcaption><\/figure>\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-pfsm-02-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u94fa\u8bbe\u53cd\u5c04\u819c\" loading=\"lazy\"><figcaption>\u94fa\u8bbe\u53cd\u5c04\u819c<\/figcaption><\/figure>\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lhya-zls-dnpg-04-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u6837\u8c8c\" loading=\"lazy\"><figcaption>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u6837\u8c8c<\/figcaption><\/figure>\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/mlxz-bls-dn-fjsq-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u5206\u96c6\u6c34\u5668\u5b89\u88c5\" loading=\"lazy\"><figcaption>\u5206\u96c6\u6c34\u5668\u5b89\u88c5<\/figcaption><\/figure>\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E4%BF%9D%E5%8E%8B1-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u6253\u538b\u6d4b\u8bd5 \u00b7 0.6-0.8MPa\u7a33\u538b\" loading=\"lazy\"><figcaption>\u6253\u538b\u6d4b\u8bd5 \u00b7 0.6\u20130.8MPa \u7a33\u538b<\/figcaption><\/figure>\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E5%9B%9E%E5%A1%AB3-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b \u00b7 \u4fdd\u62a4\u7ba1\u9053\" loading=\"lazy\"><figcaption>\u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b \u00b7 \u4fdd\u62a4\u7ba1\u9053<\/figcaption><\/figure>\n        <\/div>\n        <div class=\"ppt-desc\">\u6309\u8bbe\u8ba1\u56fe\u94fa\u8bbe\u76d8\u7ba1\u3001\u63a7\u5236\u95f4\u8ddd\u4e0e\u56de\u8def\u957f\u5ea6\uff1b<b>\u6253\u538b\u6d4b\u8bd5 + \u8c46\u77f3\u6df7\u51dd\u571f\u56de\u586b<\/b>\uff0c\u6bcf\u9053\u5de5\u5e8f\u62cd\u7167\u5b58\u6863\u3002\u6253\u538b\u4f9d\u636e GB 50242-2002\uff1a0.6\u20130.8 MPa \u7a33\u538b \u22651 \u5c0f\u65f6\u3001\u538b\u964d \u22640.05 MPa\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">05<\/span><span class=\"ppt-title\">\u7cfb\u7edf\u8c03\u8bd5 \u00b7 \u9505\u7089\u5b89\u88c5<\/span><\/div>\n        <div class=\"ppt-imgs i2\">\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E8%B0%83%E8%AF%951-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u9505\u7089\u5b89\u88c5 \u00b7 \u7ba1\u9053\u8fde\u63a5\u5c31\u4f4d\" loading=\"lazy\"><figcaption>\u9505\u7089\u5b89\u88c5 \u00b7 \u7ba1\u9053\u8fde\u63a5\u5c31\u4f4d<\/figcaption><\/figure>\n          <figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E8%B0%83%E8%AF%952-768x1024.jpg\" width=\"768\" height=\"1024\" alt=\"\u7cfb\u7edf\u8c03\u8bd5 \u00b7 \u53c2\u6570\u8bbe\u5b9a\u9a8c\u8bc1\" loading=\"lazy\"><figcaption>\u7cfb\u7edf\u8c03\u8bd5 \u00b7 \u53c2\u6570\u8bbe\u5b9a\u9a8c\u8bc1<\/figcaption><\/figure>\n        <\/div>\n        <div class=\"ppt-desc\">\u9505\u7089\u5c31\u4f4d\u3001\u7ba1\u9053\u8fde\u63a5\uff0c\u7cfb\u7edf\u6ce8\u6c34\u6392\u6c14\u540e\u8c03\u8bd5\u8fd0\u884c\uff0c\u9a8c\u8bc1\u8054\u52a8\u63a7\u5236\u903b\u8f91\uff0c\u786e\u4fdd\u5404\u56de\u8def\u6d41\u91cf\u5747\u5300\u3001\u5206\u5ba4\u6e29\u63a7\u6b63\u5e38\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">06<\/span><span class=\"ppt-title\">\u7ae3\u5de5\u9a8c\u6536<\/span><\/div>\n        <div class=\"ppt-desc\">\u6240\u6709\u9690\u853d\u5de5\u7a0b\u5f71\u50cf\u8d44\u6599\u5f52\u6863\uff0c\u9010\u9879\u9a8c\u6536\u7b7e\u5b57\u3002\u786e\u8ba4\u4f9b\u6696\u6548\u679c\u3001\u6e29\u63a7\u5668\u64cd\u4f5c\u6b63\u5e38\uff0c\u4ea4\u4ed8\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u3002<br>\u4ea4\u4ed8\u7269\u6e05\u5355\uff1a\u65bd\u5de5\u5f71\u50cf\u6863\u6848\uff08\u7535\u5b50\u7248\uff09\u2192 \u6253\u538b\u9a8c\u6536\u8bb0\u5f55 \u2192 \u7cfb\u7edf\u53c2\u6570\u8bbe\u5b9a\u8868 \u2192 \u4f7f\u7528\u624b\u518c \u2192 \u7d27\u6025\u8054\u7cfb\u65b9\u5f0f\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide extra\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">+1<\/span><span class=\"ppt-title\">\u4ea4\u4ed8\u6559\u5b66<\/span><\/div>\n        <div class=\"ppt-imgs i1\"><figure class=\"ppt-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/%E5%9C%B0%E6%9A%96%E6%95%99%E5%AD%A62-752x1024.jpg\" width=\"752\" height=\"1024\" alt=\"\u4e00\u5bf9\u4e00\u4ea4\u4ed8\u6559\u5b66 \u00b7 \u6e29\u63a7\u5668\u4f7f\u7528\u8bb2\u89e3\" loading=\"lazy\"><figcaption>\u4e00\u5bf9\u4e00\u4ea4\u4ed8\u6559\u5b66 \u00b7 \u6e29\u63a7\u5668\u4f7f\u7528\u8bb2\u89e3<\/figcaption><\/figure><\/div>\n        <div class=\"ppt-desc\">\u4e00\u5bf9\u4e00\u6559\u4f1a\u5ba2\u6237\u4f7f\u7528\u6e29\u63a7\u5668\u3001\u5207\u6362\u6a21\u5f0f\u3001\u8bfb\u53d6\u8fd0\u884c\u53c2\u6570\u3001\u7d27\u6025\u64cd\u4f5c\u5904\u7406\uff0c\u63d0\u4f9b\u7535\u5b50\u7248\u548c\u7eb8\u8d28\u7248\u4f7f\u7528\u624b\u518c\u3002<\/div>\n      <\/div>\n      <div class=\"ppt-slide extra\">\n        <div class=\"ppt-head\"><span class=\"ppt-ord\">+2<\/span><span class=\"ppt-title\">\u552e\u540e\u4fdd\u969c<\/span><\/div>\n        <div class=\"ppt-desc\">\u4ea4\u4ed8\u540e\u6bcf\u5e74\u91c7\u6696\u5b63\u4e3b\u52a8\u56de\u8bbf\uff0c\u91c7\u96c6\u80fd\u8017\u6570\u636e\uff0c\u540c\u6237\u578b\u5bf9\u6807\u5206\u6790\u300210 \u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff0c\u5f02\u5e38\u80fd\u8017\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u3002<br>10 \u5e74\u4fdd\u969c\u627f\u8bfa\uff1a\u80fd\u8017\u6570\u636e\u9010\u5e74\u5f52\u6863 \u2192 \u540c\u6237\u578b\u5bf9\u6807\u5206\u6790 \u2192 \u5f02\u5e38\u4e3b\u52a8\u9884\u8b66 \u2192 \u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u4f18\u5316\u3002<\/div>\n      <\/div>\n    <\/div>\n    <button class=\"ppt-arrow ppt-prev\" type=\"button\" aria-label=\"\u4e0a\u4e00\u9875\">\u2039<\/button>\n    <button class=\"ppt-arrow ppt-next\" type=\"button\" aria-label=\"\u4e0b\u4e00\u9875\">\u203a<\/button>\n    <div class=\"ppt-nav\">\n      <div class=\"ppt-dots\"><span class=\"ppt-dot on\"><\/span><span class=\"ppt-dot\"><\/span><span class=\"ppt-dot\"><\/span><span class=\"ppt-dot\"><\/span><span class=\"ppt-dot\"><\/span><span class=\"ppt-dot\"><\/span><span class=\"ppt-dot\"><\/span><span class=\"ppt-dot\"><\/span><\/div>\n      <span class=\"ppt-count\">1 \/ 8<\/span>\n    <\/div>\n  <\/div>\n  <div class=\"trust\"><b>\u914d\u5957\u4fdd\u969c\uff1a<\/b>\u7cbe\u5de5\u516d\u6b65\u6cd5\uff08\u6807\u51c6\u5316\u6d41\u7a0b\uff0c\u6b65\u6b65\u53ef\u8ffd\u6eaf\uff09\u00b7 \u6253\u538b\u9a8c\u6536\uff0836 \u9879\u8282\u70b9\u9a8c\u6536\uff0c\u4e0d\u653e\u8fc7\u4efb\u4f55\u7ec6\u8282\uff09\u00b7 \u65e0\u5c18\u65bd\u5de5\uff08\u5168\u7a0b\u9632\u5c18\u62a4\u5177\uff0c\u65bd\u5de5\u524d\u540e\u6574\u6d01\u5982\u521d\uff09\u3002\u6253\u538b\u4f9d\u636e GB 50242-2002\uff1a0.6\u20130.8 MPa \u7a33\u538b \u22651 \u5c0f\u65f6\u3001\u538b\u964d \u22640.05 MPa\u3002<\/div>\n\n  <h3 class=\"st\">\u65bd\u5de5\u9a8c\u6536\u6807\u51c6\uff08\u9690\u853d\u5de5\u7a0b\uff0c\u6700\u4e0d\u80fd\u7701\uff09<\/h3>\n  <table class=\"tbl\">\n    <thead><tr><th>\u8282\u70b9<\/th><th>\u6807\u51c6<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u6253\u538b\u8bd5\u9a8c<\/td><td>0.6MPa \u7a33\u538b \u22651h\uff0c\u538b\u964d \u22640.05MPa\uff08GB 50242-2002\uff09<\/td><\/tr>\n      <tr><td>\u76d8\u7ba1\u95f4\u8ddd<\/td><td>\u504f\u5dee \u2264\u00b110mm\uff0c\u65e0\u63a5\u5934<\/td><\/tr>\n      <tr><td>\u56de\u586b<\/td><td>C15 \u8c46\u77f3\u6df7\u51dd\u571f\uff0c\u8986\u76d6\u76d8\u7ba1\u6309 <b>40\u201350mm<\/b>\uff08\u6700\u4f4e \u226530mm\uff09\uff0c\u81ea\u7136\u517b\u62a4 \u22657 \u5929\uff08\u7981\u70d8\u5e72\uff09<\/td><\/tr>\n      <tr><td>\u9996\u6b21\u5347\u6e29<\/td><td>\u4f9b\u6c34\u4ece 30\u2103 \u8d77\uff0c\u6bcf\u5929\u5347 5\u2103\uff0c3\u20135 \u5929\u5347\u81f3 45\u2103<\/td><\/tr>\n      <tr><td>\u8fc7\u7a0b\u7559\u6863<\/td><td>\u76d8\u7ba1\u5168\u666f\u3001\u5206\u96c6\u6c34\u5668\u63a5\u7ebf\u3001\u6253\u538b\u8bfb\u6570\u62cd\u7167\u5b58\u6863<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <h3 class=\"st\">\u5e38\u89c1\u95ee\u9898\u4e0e\u6211\u4eec\u7684\u89e3\u6cd5<\/h3>\n  <table class=\"tbl\">\n    <thead><tr><th>\u5e38\u89c1\u75db\u70b9<\/th><th>\u901a\u914d\u505a\u6cd5<\/th><th>\u9f99\u8109\u89e3\u6cd5<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u8fd0\u884c\u8d39\u9ad8<\/td><td>\u5927\u9a6c\u62c9\u5c0f\u8f66\u3001\u76f2\u76ee\u70e7<\/td><td>\u529f\u7387\u5339\u914d + \u6c34\u529b\u5e73\u8861 + \u8054\u52a8\uff0c\u7701 20\u201330%+<\/td><\/tr>\n      <tr><td>\u6709\u7684\u623f\u95f4\u70ed\u6709\u7684\u51b7<\/td><td>\u5f02\u7a0b\u3001\u65e0\u5e73\u8861<\/td><td>\u540c\u7a0b\u7ba1\u8def + \u6bcf\u652f\u8def\u5e73\u8861\u9600\uff0c\u6e29\u5dee \u00b11\u2103<\/td><\/tr>\n      <tr><td>\u9505\u7089\u9891\u7e41\u542f\u505c\u566a\u97f3<\/td><td>\u529f\u7387\u8d85\u914d<\/td><td>\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa 3\u20134kW\uff0c\u8fde\u7eed\u8fd0\u884c<\/td><\/tr>\n      <tr><td>\u7ba1\u9053\u9ed1\u6c34\u5f02\u5473<\/td><td>\u975e\u963b\u6c27\u7ba1<\/td><td>\u4f1f\u661f\u963b\u6c27\u7ba1\u8def\uff0c5 \u5e74\u6548\u7387\u4e0d\u8870\u51cf<\/td><\/tr>\n      <tr><td>\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed<\/td><td>\u4e24\u7528\u7089\u517c\u987e<\/td><td>\u91c7\u6696\/\u70ed\u6c34\u5206\u79bb\uff08\u7cfb\u7edf\u7089+\u72ec\u7acb\u70ed\u6c34\u5668\uff09<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"callout\">\n    <div class=\"ttl\">20 \u5e74\u603b\u8d26\u89c6\u89d2<\/div>\n    \u521d\u88c5\u7701\u4e0b\u7684\u51e0\u5343\u5143\uff0c\u5f80\u5f80\u5728 3\u20135 \u5e74\u5185\u88ab\u591a\u70e7\u7684\u71c3\u6c14\u4e0e\u6545\u969c\u7ef4\u4fee\u5403\u6389\u3002\u5730\u6696\u662f<b>\u4e0e\u5efa\u7b51\u540c\u5bff<\/b>\u7684\u9690\u853d\u5de5\u7a0b\uff08\u76d8\u7ba1\u4e0d\u6362\uff09\uff0c\u4e13\u4e1a\u8bbe\u8ba1\u8ba9\u5b83\u5728 20 \u5e74\u91cc\u6301\u7eed\u7701\u6c14\u3001\u7a33\u5b9a\u65e0\u6270\u2014\u2014\u8fd9\u624d\u662f\"\u8212\u9002\u7406\u8d22\"\u3002\n  <\/div>\n\n  <h3 class=\"st\">10 \u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212 \u00b7 \u957f\u671f\u8ddf\u8e2a\uff0c\u7528\u6570\u636e\u8bf4\u8bdd<\/h3>\n  <div class=\"grid2\">\n    <div class=\"card\"><div class=\"ct\">A \u7ec4 \u00b7 \u8282\u80fd\u65b9\u6848\u7ec4<\/div><ul>\n      <li>\u672c\u6237\u81ea\u52a8\u52a0\u5165\uff0c\u4eab\u53d7 <b>10 \u5e74\u80fd\u6e90\u8ddf\u8e2a\u670d\u52a1<\/b><\/li>\n      <li>\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\u56de\u8bbf\u3001\u91c7\u96c6\u8fd0\u884c\u6570\u636e<\/li>\n      <li>\u540c\u6237\u578b\u80fd\u8017\u5bf9\u6807\u5206\u6790 + \u7cfb\u7edf\u4f18\u5316\u5efa\u8bae\uff08\u4e3b\u52a8\u63a8\u9001\uff09<\/li>\n      <li>\u8131\u654f\u540e\u6570\u636e\u9690\u79c1\u4fdd\u62a4<\/li>\n    <\/ul><\/div>\n    <div class=\"card\"><div class=\"ct\">\u5bf9\u7167\u7ec4 \u00b7 \u5bf9\u6807\u57fa\u51c6<\/div><ul>\n      <li>\u540c\u6237\u578b\u3001\u540c\u671f\u5b89\u88c5\u5ba2\u6237\u7684 <b>\u80fd\u8017\u8131\u654f\u6570\u636e<\/b><\/li>\n      <li>\u4f5c\u4e3a\u5bf9\u6bd4\u57fa\u51c6\uff0c\u505a\u5e74\u80fd\u8017\u73af\u6bd4\u5206\u6790<\/li>\n      <li>\u63d0\u4f9b\u8282\u80fd\u6539\u9020\u53c2\u8003<\/li>\n      <li>\u4e0d\u6536\u53d6\u989d\u5916\u8d39\u7528<\/li>\n    <\/ul><\/div>\n  <\/div>\n  <div class=\"trust\"><b>\u4fdd\u969c\u627f\u8bfa\uff1a<\/b>10 \u5e74\u5185\u82e5\u7cfb\u7edf\u51fa\u73b0\u8bbe\u8ba1\u6216\u5b89\u88c5\u8d28\u91cf\u95ee\u9898\u5bfc\u81f4\u7684\u80fd\u8017\u5f02\u5e38\uff0c\u9f99\u8109\u6696\u901a\u514d\u8d39\u4e0a\u95e8\u8bca\u65ad\u5e76\u8c03\u6574\u3002<\/div>\n<\/section>\n\n<!-- \u603b\u7ed3 -->\n<section id=\"summary\">\n  <div class=\"sec-h\"><span class=\"no\">\u2713<\/span><h2>\u4e00\u53e5\u8bdd\u603b\u7ed3\u4e0e\u5efa\u8bae<\/h2><\/div>\n  <div class=\"callout\">\n    \u674e\u5973\u58eb 71\u33a1 \u5730\u6696\uff0c\u6211\u4eec\u5efa\u8bae\uff1a<b>\u9f99\u8109\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\uff08\u4f1f\u661f\u5168\u5957\u7ba1\u8def\uff0c169\u5143\/\u33a1\uff09+ \u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089\uff08\u66fc\u745e\u5fb7 L1PB26\uff0c24kW\uff09<\/b>\u3002<br>\n    \u9505\u7089\u4e0d\u5fc5\u4e0a\u51b7\u51dd\u7089\u2014\u201471\u33a1 \u70ed\u91cf\u9700\u6c42\u5c0f\uff0c\u51b7\u51dd\u7089\u521d\u6295\u9ad8\u3001\u56de\u6536\u96be\uff1b<b>\u53d8\u9891\u5206\u6bb5\u666e\u901a\u7089<\/b>\u70ed\u6c34\u5206\u6bb5\u6052\u6e29\u3001\u6700\u5c0f\u8f93\u51fa\u8d34\u5408\u3001\u6295\u5165\u4f4e\uff0c\u914d\u5408\u4e13\u4e1a\u8282\u80fd\u7cfb\u7edf\u8bbe\u8ba1\uff0c\u7efc\u5408\u6700\u4f18\u3002<br>\n    \u6309 GB 50736 \/ JGJ 142 \u8bbe\u8ba1\uff0c<b>\u5168\u5c4b\u6e29\u5dee \u00b11\u2103\u3001\u6bcf\u6708\u71c3\u6c14\u8d39\u7ea6 500\u2013600 \u5143<\/b>\u3002<br>\n    <b>\u6295\u8d44\u7ea6 18,198 \u5143<\/b>\uff08\u82e5\u9009\u51b7\u51dd\u7089\u7ea6 23,499 \u5143\uff09\u3002<br>\n    <span style=\"color:var(--gold-dim)\">\u5efa\u8bae\u9884\u7ea6\u4e0a\u95e8\u52d8\u6d4b\uff0c\u4f9d\u636e\u5899\u4f53\u4fdd\u6e29\u4e0e\u671d\u5411\u590d\u6838\u70ed\u8d1f\u8377\uff0c\u636e\u6b64\u5b9a\u7a3f\u5e76\u9501\u5b9a\u4ef7\u683c\u3002<\/span>\n  <\/div>\n<\/section>\n\n<section id=\"verify\">\n  <div class=\"sec-h\"><span class=\"no\">AI<\/span><h2>\u6570\u636e\u6e90\u4e0e\u9a8c\u8bc1<\/h2><\/div>\n  <div class=\"verify\">\n    <div class=\"ok\">\u2705 \u70ed\u8d1f\u8377\uff1a<a class=\"src-link\" href=\"https:\/\/longmai-nt.com\/?page_id=601\" target=\"_blank\" rel=\"noopener\">GB 50736-2012<\/a> \u9010\u623f\u8ba1\u7b97\uff0871\u33a1 \u22487.1kW\uff09<\/div>\n    <div class=\"ok\">\u2705 \u8bbe\u8ba1\u53c2\u6570\uff1a<a class=\"src-link\" href=\"https:\/\/longmai-nt.com\/?page_id=601\" target=\"_blank\" rel=\"noopener\">JGJ 142-2012<\/a> \u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/div>\n    <div class=\"ok\">\u2705 \u7ba1\u6750\uff1a\u4f1f\u661f A+ \u7ba1\u9053\u7cfb\u7edf\uff08\u8fdb\u53e3 II \u578b PE-RT\uff0c\u68c0\u6d4b\u62a5\u544a\u5df2\u6838\uff09<\/div>\n    <div class=\"ok\">\u2705 \u9505\u7089\uff1a\u6307\u4ee42 \u4ea7\u54c1\u4ef7\u683c\u5e93\uff08\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u7089 L1PB26-Heidelberg Min.\uff0c\u5355\u4ef7\u4e0d\u6253\u6298\uff09<\/div>\n    <div class=\"ok\">\u2705 \u62a5\u4ef7\u5b9a\u4f4d\uff1a\u6280\u672f\u6807\uff0c\u4e0d\u5c01\u5e95\u4ef7\uff0c\u6700\u7ec8\u4ee5\u5408\u540c\u9501\u4ef7\u5355\u4e3a\u51c6<\/div>\n  <\/div>\n  <div class=\"footaddr\">\u6570\u636e\u6e90\uff1a<a class=\"src-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\" rel=\"noopener\">\u9f99\u8109\u6696\u901a\u5730\u6696\u77e5\u8bc6\u5e95\u5ea7<\/a>\uff08\u5730\u6696\u805a\u5408\u9875\u4e0a\/\u4e0b\u518c\u300102\u91c7\u6696\u6280\u672f\u624b\u518c\u3001\u4f1f\u661f\u7ba1\u9053\u8d44\u6599\uff09+ \u6307\u4ee42 \u4ea7\u54c1\u4ef7\u683c\u5e93 \uff5c \u751f\u6210\u65e5\u671f 2026-09-13<\/div>\n<\/section>\n\n<!-- \u95e8\u5e97\u4fe1\u606f\u4e0e\u8054\u7cfb\u65b9\u5f0f -->\n<section class=\"store-sec\" id=\"stores\">\n  <div class=\"sec-h\"><span class=\"no\">\u25ce<\/span><h2>\u95e8\u5e97\u4fe1\u606f\u4e0e\u8054\u7cfb\u65b9\u5f0f<\/h2><span class=\"tag\">\u6b22\u8fce\u5230\u5e97\u4f53\u9a8c<\/span><\/div>\n  <div class=\"store-contacts\">\n    <a class=\"sc-item\" href=\"tel:02886131795\"><span class=\"sc-ic\">\ud83c\udfec<\/span><span class=\"sc-info\"><span class=\"sc-label\">\u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/span><span class=\"sc-phone\">028-86131795<\/span><\/span><\/a>\n    <a class=\"sc-item\" href=\"tel:02865272586\"><span class=\"sc-ic\">\ud83c\udfec<\/span><span class=\"sc-info\"><span class=\"sc-label\">\u6210\u534e\u533a\u5e97<\/span><span class=\"sc-phone\">028-65272586<\/span><\/span><\/a>\n    <a class=\"sc-item\" href=\"tel:13008113409\"><span class=\"sc-ic\">\ud83d\udc64<\/span><span class=\"sc-info\"><span class=\"sc-label\">\u8bbe\u8ba1\u987e\u95ee<\/span><span class=\"sc-phone\">\u4f59\u6653\u73b2 130-0811-3409<\/span><\/span><\/a>\n  <\/div>\n  <div class=\"store-grid\">\n    <div class=\"store-card\">\n      <div class=\"store-label\">\u25ce \u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store-1024x444.jpg\" width=\"1024\" height=\"444\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n      <div class=\"store-addr\">\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348 \u00b7 <a href=\"tel:02886131795\">028-86131795<\/a><\/div>\n    <\/div>\n    <div class=\"store-card\">\n      <div class=\"store-label\">\u25ce \u6210\u534e\u533a\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store-1024x434.jpg\" width=\"1024\" height=\"434\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u534e\u533a\u5e97\u5b9e\u666f\" loading=\"lazy\">\n      <div class=\"store-addr\">\u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7 \u00b7 <a href=\"tel:02865272586\">028-65272586<\/a><\/div>\n    <\/div>\n  <\/div>\n  <div class=\"store-cta\"><a href=\"tel:13008113409\">\u9884\u7ea6\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u51fa\u5177\u6b63\u5f0f\u62a5\u4ef7<\/a><\/div>\n<\/section>\n\n<div class=\"note\">\n  \u672c\u65b9\u6848\u4e66\u4e3a\u6280\u672f\u6807\uff08\u975e\u4ef7\u683c\u6807\uff09\u3002\u9884\u7ea6\u52d8\u6d4b\/\u9501\u4ef7\uff1a\u5357\u5bcc\u68ee\u65d7\u8230\u5e97 028-86131795\u3002\n<\/div>\n\n<\/div>\n<\/div>\n\n<script>\n(function(){\n  var bar = document.getElementById('tocbar');\n  if(!bar) return;\n  var links = [].slice.call(bar.querySelectorAll('a'));\n  var targets = links.map(function(a){ return document.querySelector(a.getAttribute('href')); });\n  function onScroll(){\n    var y = window.pageYOffset + bar.offsetHeight + 16, idx = 0;\n    targets.forEach(function(t,i){ if(t && t.getBoundingClientRect().top + window.pageYOffset <= y) idx = i; });\n    links.forEach(function(a,i){ a.classList.toggle('on', i === idx); });\n  }\n  window.addEventListener('scroll', onScroll, {passive:true});\n  window.addEventListener('resize', onScroll);\n  onScroll();\n})();\n\n\/\/ \u4ea7\u54c1\u5361\u724c\u70b9\u51fb\u7ffb\u8f6c\n[].slice.call(document.querySelectorAll('.flip-card')).forEach(function(card){\n  card.addEventListener('click', function(){ card.classList.toggle('flipped'); });\n});\n\n\/\/ ===== \u516d\u6b65\u6cd5 \u5206\u9875\u6d4f\u89c8\uff08\u5de6\u53f3\u5927\u6309\u94ae\u7ffb\u9875\uff0c\u65e0\u81ea\u52a8\u64ad\u653e\uff09 =====\n(function(){\n  var ppt = document.getElementById('projPpt');\n  if(!ppt) return;\n  var stage = ppt.querySelector('.ppt-stage');\n  var slides = [].slice.call(ppt.querySelectorAll('.ppt-slide'));\n  var dots = [].slice.call(ppt.querySelectorAll('.ppt-dot'));\n  var arrows = ppt.querySelectorAll('.ppt-arrow');\n  var count = ppt.querySelector('.ppt-count');\n  var i = 0;\n  function syncHeight(){\n    if(!stage) return;\n    var h = slides[i].offsetHeight;\n    if(h > 0) stage.style.height = h + 'px';\n  }\n  function go(n){\n    if(stage) stage.style.height = stage.offsetHeight + 'px'; \/\/ \u9501\u5b9a\u5f53\u524d\u9ad8\u5ea6\u4f5c\u4e3a\u8fc7\u6e21\u8d77\u70b9\n    i = (n + slides.length) % slides.length;\n    slides.forEach(function(s,k){ s.classList.toggle('is-active', k === i); });\n    dots.forEach(function(d,k){ d.classList.toggle('on', k === i); });\n    if(count) count.textContent = (i+1) + ' \/ ' + slides.length;\n    if(stage) void stage.offsetHeight; \/\/ \u5f3a\u5236\u56de\u6d41\u540e\u518d\u53d6\u65b0\u9875\u9ad8\u5ea6\n    syncHeight();\n  }\n  if(arrows[0]) arrows[0].addEventListener('click', function(){ go(i-1); });\n  if(arrows[1]) arrows[1].addEventListener('click', function(){ go(i+1); });\n  dots.forEach(function(d,k){ d.addEventListener('click', function(){ go(k); }); });\n  go(0);\n  window.addEventListener('load', syncHeight);\n  window.addEventListener('resize', syncHeight);\n})();\n\n\/\/ ===== \u7089\u578b\u5bf9\u6bd4\u96f7\u8fbe\u56fe\uff08\u5f02\u6b65\u52a0\u8f7d ECharts\uff0c\u4e0d\u963b\u585e\u5176\u4ed6\u4ea4\u4e92\uff09 =====\n(function(){\n  var el = document.getElementById('radarVs');\n  if(!el) return;\n  function build(){\n  if(!window.echarts){\n    el.innerHTML = '<div style=\"height:100%;display:flex;align-items:center;justify-content:center;color:#6f6b63;font-size:13px;text-align:center;padding:20px\">\u96f7\u8fbe\u56fe\u9700\u8054\u7f51\u52a0\u8f7d\uff08ECharts CDN\uff09\uff0c\u5f53\u524d\u672a\u52a0\u8f7d\u6210\u529f\uff1b\u8bf7\u53c2\u8003\u4e0b\u65b9\u6307\u6807\u8981\u70b9\u3002<\/div>';\n    return;\n  }\n  var chart = echarts.init(el);\n  chart.setOption({\n    color:['#c8a24a','#3f8f5f'],\n    tooltip:{},\n    legend:{ data:['\u5e38\u89c4\u7089','\u51b7\u51dd\u7089'], bottom:0, textStyle:{ color:'#6f6b63' } },\n    radar:{\n      indicator:[\n        { name:'\u70ed\u6548\u7387', max:100 },\n        { name:'\u6392\u70df\u6e29\u5ea6', max:100 },\n        { name:'\u6f5c\u70ed\u56de\u6536', max:100 },\n        { name:'\u6700\u5c0f\u8f93\u51fa\u7a33\u5b9a', max:100 },\n        { name:'\u6362\u70ed\u5668\u8010\u8680', max:100 },\n        { name:'\u5730\u6696\u672b\u7aef\u9002\u914d', max:100 },\n        { name:'\u521d\u6295\u8d44\u4f18\u52bf', max:100 }\n      ],\n      center:['50%','46%'], radius:'62%',\n      axisName:{ color:'#6f6b63', fontSize:12 },\n      splitLine:{ lineStyle:{ color:'rgba(156,122,60,.25)' } },\n      splitArea:{ areaStyle:{ color:['rgba(156,122,60,.04)','rgba(156,122,60,.08)'] } },\n      axisLine:{ lineStyle:{ color:'rgba(156,122,60,.25)' } }\n    },\n    series:[{\n      type:'radar',\n      symbolSize:5,\n      areaStyle:{ opacity:.28 },\n      lineStyle:{ width:2 },\n      data:[\n        { value:[60,35,30,45,50,45,90], name:'\u5e38\u89c4\u7089' },\n        { value:[95,92,95,92,88,90,45], name:'\u51b7\u51dd\u7089' }\n      ]\n    }]\n  });\n  window.addEventListener('resize', function(){ chart.resize(); });\n  }\n  if(window.echarts){ build(); return; }\n  var s = document.createElement('script');\n  s.src = 'https:\/\/cdn.jsdelivr.net\/npm\/echarts@5.5.0\/dist\/echarts.min.js';\n  s.async = true;\n  s.onload = build;\n  s.onerror = build;\n  document.head.appendChild(s);\n})();\n\n\/\/ ===== \u56db\u5927\u8981\u7d20\u8fdb\u5ea6\u6761\uff1a\u4f9d\u6b21\u63a8\u8fdb + \u968f\u673a\u65b9\u5411\u5c55\u793a\u8be6\u60c5 =====\n(function(){\n  var box = document.getElementById('flow4');\n  if(!box) return;\n  var fill = box.querySelector('.flow4-fill');\n  var nodes = [].slice.call(box.querySelectorAll('.flow4-node'));\n  var detail = box.querySelector('.flow4-detail');\n  var DATA = [\n    {ic:'\ud83d\udd25', t:'\u2460 \u70ed\u6e90', items:['\u71c3\u6c14\u58c1\u6302\u7089\uff08\u51b7\u51dd\u7089\u4f18\u5148\uff09','\u529f\u7387<b>\u5339\u914d<\/b>\uff1a\u6700\u5927 \/ \u6700\u5c0f\u529f\u7387\u90fd\u4e0d\u8d85\u914d','\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa 3\u20134kW\uff0c\u9632\u9891\u7e41\u542f\u505c']},\n    {ic:'\ud83d\udd27', t:'\u2461 \u8f93\u914d', items:['\u4f1f\u661f\u963b\u6c27\u7ba1\u8def + \u5206\u96c6\u6c34\u5668','\u540c\u7a0b \/ \u7ae0\u9c7c\u5f0f\u5e03\u7ba1\uff0c\u5404\u652f\u8def\u7b49\u957f','\u4e3b\u7ba1 De32 \u8d77\uff0c\u4fdd\u8bc1\u6d41\u91cf']},\n    {ic:'\u2668\ufe0f', t:'\u2462 \u672b\u7aef', items:['\u5730\u6696\u76d8\u7ba1 35\u201345\u2103 \u4f4e\u6e29\u8f90\u5c04','\u76d8\u7ba1\u95f4\u8ddd\u6309\u70ed\u8d1f\u8377\u8bbe\u8ba1','\u4fdd\u6e29 + \u53cd\u5c04\u819c + \u84c4\u70ed\u56de\u586b']},\n    {ic:'\ud83c\udf9b\ufe0f', t:'\u2463 \u63a7\u5236', items:['\u6e29\u63a7\u5668\u4e0e\u9505\u7089<b>\u8054\u52a8<\/b>\uff08\u5ba4\u6e29\u8fbe\u6807\u5373\u505c\uff09','\u5206\u5ba4\u63a7\u6e29\uff0c\u53ea\u70e7\u5728\u7528\u7684\u623f\u95f4','\u6c14\u5019\u8865\u507f + APP \u8fdc\u7a0b\u9884\u70ed']}\n  ];\n  var cur = 0, timer = null, GAP = 1700;\n  function show(k){\n    cur = k;\n    var d = DATA[k];\n    nodes.forEach(function(n,x){ n.classList.toggle('on', x === k); });\n    fill.style.width = 'calc((100% - 80px) * ' + (k \/ (DATA.length - 1)) + ')';\n    detail.classList.remove('show');\n    var dx = (Math.random() < .5 ? -1 : 1) * (14 + Math.round(Math.random()*22));\n    detail.style.setProperty('--dx', dx + 'px');\n    detail.innerHTML = '<div class=\"fd-tt\"><span>' + d.ic + '<\/span>' + d.t + '<\/div><ul>' + d.items.map(function(x){ return '<li>' + x + '<\/li>'; }).join('') + '<\/ul>';\n    void detail.offsetWidth;\n    detail.classList.add('show');\n  }\n  function stop(){ if(timer){ clearInterval(timer); timer = null; } }\n  function start(){ stop(); timer = setInterval(function(){ show((cur + 1) % DATA.length); }, GAP); }\n  nodes.forEach(function(n,k){\n    n.addEventListener('click', function(){ show(k); start(); });\n  });\n  var begin = function(){ show(0); start(); };\n  if('IntersectionObserver' in window){\n    var io = new IntersectionObserver(function(es){\n      es.forEach(function(e){ if(e.isIntersecting){ begin(); io.disconnect(); } });\n    }, {threshold:.3});\n    io.observe(box);\n  } else { begin(); }\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u5c01\u9762 \u9700\u6c42\u8bca\u65ad \u7cfb\u7edf\u89c2 \u4e13\u4e1a vs \u901a\u914d [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-12501","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=12501\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5c01\u9762 \u9700\u6c42\u8bca\u65ad \u7cfb\u7edf\u89c2 \u4e13\u4e1a vs \u901a\u914d [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=12501\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-13T15:39:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501\",\"name\":\"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\",\"datePublished\":\"2026-09-13T14:38:37+00:00\",\"dateModified\":\"2026-09-13T15:39:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\",\"width\":454,\"height\":781},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=12501#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=12501","og_locale":"zh_CN","og_type":"article","og_title":"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u5c01\u9762 \u9700\u6c42\u8bca\u65ad \u7cfb\u7edf\u89c2 \u4e13\u4e1a vs \u901a\u914d [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=12501","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-09-13T15:39:48+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=12501","url":"https:\/\/longmai-nt.com\/?page_id=12501","name":"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=12501#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=12501#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","datePublished":"2026-09-13T14:38:37+00:00","dateModified":"2026-09-13T15:39:48+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=12501#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=12501"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=12501#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","width":454,"height":781},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=12501#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u674e\u5973\u58eb \u00b7 \u5168\u5c4b\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/12501","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=12501"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/12501\/revisions"}],"predecessor-version":[{"id":12511,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/12501\/revisions\/12511"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=12501"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}