{"id":13011,"date":"2026-09-22T16:01:51","date_gmt":"2026-09-22T08:01:51","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=13011"},"modified":"2026-11-03T13:30:02","modified_gmt":"2026-11-03T05:30:02","slug":"%e9%98%bf%e5%b0%94%e8%8e%8e%e5%a8%9c%e4%b8%ad%e5%a4%ae%e8%bd%af%e6%b0%b4","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=13011","title":{"rendered":"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34"},"content":{"rendered":"\n<div style=\"font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,'PingFang SC','Microsoft YaHei',sans-serif;color:#1f2937;line-height:1.75;\">\n\n   <p style=\"font-size:1.05em;color:#475569;\">\u4e2d\u592e\u8f6f\u6c34\u673a\uff08\u4e1a\u5185\u79f0<strong>\u4e2d\u8f6f<\/strong>\uff09\u662f\u963f\u5c14\u838e\u5a1c\u5168\u5c4b\u51c0\u6c34\u4e94\u4ef6\u5957\u91cc\u7684\u7b2c\u4e09\u5173\uff0c\u88c5\u5728\u4e2d\u592e\u51c0\u6c34\u673a\u4e4b\u540e\u3001\u53a8\u4e0b\u673a\u4e4b\u524d\uff0c\u4e13\u95e8<strong>\u53bb\u9664\u6c34\u4e2d\u7684\u9499\u9541\u79bb\u5b50<\/strong>\u2014\u2014\u4e5f\u5c31\u662f\"\u6c34\u57a2\u5143\u51f6\"\u3002\u8f6f\u6c34\u6d17\u6d74\u66f4\u987a\u6ed1\u3001\u8863\u7269\u66f4\u84ec\u677e\u3001\u6d89\u6c34\u5bb6\u7535\uff08\u70ed\u6c34\u5668\/\u6d17\u7897\u673a\/\u6b27\u6807\u82b1\u6d12\uff09\u5c11\u7ed3\u57a2\u3001\u5bff\u547d\u66f4\u957f\u3002\u672c\u6587\u8bb2\u6e05\u8f6f\u6c34\u539f\u7406\u3001\u963f\u5c14\u838e\u5a1c\u4e24\u5927\u7cfb\u5217\uff08\u65e5\u7acb\u6631\u4eab R \/ \u963f\u6ce2\u7f57 R\uff09\u578b\u53f7\u53c2\u6570\uff0c\u4ee5\u53ca\u6309\u6237\u578b\u600e\u4e48\u9009\u3002<\/p>\n\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u4e00\u3001\u4e2d\u8f6f\u89e3\u51b3\u4ec0\u4e48\uff1a\u786c\u6c34\u5bb6\u5ead\u7684\"\u54c1\u8d28\u5f00\u5173\"<\/h2>\n  <p>\u81ea\u6765\u6c34\u542b\u9499\u9541\u79bb\u5b50\uff0c\u6d53\u5ea6\u9ad8\u5c31\u662f\"\u786c\u6c34\"\u3002\u884c\u4e1a\u7ecf\u9a8c\u754c\u5b9a\uff1a\u8f6f\u6c34 0\u201350mg\/L\u3001\u4e2d\u786c 150\u2013300\u3001\u786c\u6c34 300\u2013450\u3001\u9ad8\u786c 450\u2013700\u3002\u6210\u90fd\u4e0d\u5c11\u533a\u57df\u6c34\u8d28\u504f\u786c\uff0c\u957f\u671f\u7528\u786c\u6c34\u4f1a\u5e26\u6765\u4e00\u7cfb\u5217\u70e6\u607c\uff1a<\/p>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:10px;margin:16px 0;\">\n    <div style=\"border:1px solid #E8541E;border-radius:10px;padding:12px;background:#fff7f2;\"><div style=\"font-weight:700;color:#12314F;\">\u6c34\u57a2\u5835\u8bbe\u5907<\/div><div style=\"font-size:.82em;color:#64748b;margin-top:4px;\">\u70ed\u6c34\u5668\/\u82b1\u6d12\/\u9f99\u5934\u7ed3\u57a2\u3001\u51fa\u6c34\u53d8\u5c0f<\/div><\/div>\n    <div style=\"border:1px solid #E8541E;border-radius:10px;padding:12px;background:#fff7f2;\"><div style=\"font-weight:700;color:#12314F;\">\u808c\u80a4\u53d1\u6da9<\/div><div style=\"font-size:.82em;color:#64748b;margin-top:4px;\">\u786c\u6c34\u6d17\u8138\u6d17\u6fa1\u540e\u7d27\u7ef7\u3001\u6613\u75d2<\/div><\/div>\n    <div style=\"border:1px solid #E8541E;border-radius:10px;padding:12px;background:#fff7f2;\"><div style=\"font-weight:700;color:#12314F;\">\u8863\u7269\u53d1\u786c<\/div><div style=\"font-size:.82em;color:#64748b;margin-top:4px;\">\u6bdb\u5dfe\u53d8\u786c\u3001\u767d\u8272\u8863\u7269\u53d1\u9ec4<\/div><\/div>\n    <div style=\"border:1px solid #E8541E;border-radius:10px;padding:12px;background:#fff7f2;\"><div style=\"font-weight:700;color:#12314F;\">\u6d01\u5177\u7559\u6591<\/div><div style=\"font-size:.82em;color:#64748b;margin-top:4px;\">\u73bb\u7483\/\u9910\u5177\u6c34\u6e0d\u64e6\u4e0d\u6389<\/div><\/div>\n  <\/div>\n\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u4e8c\u3001\u8f6f\u6c34\u600e\u4e48\u6765\u7684\uff1a\u79bb\u5b50\u4ea4\u6362<\/h2>\n  <p style=\"font-size:.94em;color:#334155;\">\u8f6f\u6c34\u673a\u901a\u8fc7<strong>\u79bb\u5b50\u4ea4\u6362\u6811\u8102<\/strong>\uff0c\u7528\u6811\u8102\u91cc\u7684\u94a0\u79bb\u5b50\uff08Na\u207a\uff09\u7f6e\u6362\u6c34\u4e2d\u7684\u9499\u9541\u79bb\u5b50\uff0c\u5b9e\u73b0\u8f6f\u5316\u3002\u6811\u8102\u5438\u9644\u9971\u548c\u540e\u7528\u76d0\u6c34\"\u518d\u751f\"\u6062\u590d\u80fd\u529b\u3002\u963f\u5c14\u838e\u5a1c\u91c7\u7528<strong>\u7f8e\u56fd\u8fdb\u53e3\u7f57\u95e8\u54c8\u65af\u9633\u79bb\u5b50\u6811\u8102<\/strong>\uff1a<\/p>\n  <ul style=\"color:#334155;font-size:.94em;\">\n    <li>\u4ea4\u6362\u5bb9\u91cf\u66f4\u5927\uff0c\u518d\u751f\u5468\u671f\u66f4\u957f\uff1b\u4ea4\u6362\u901f\u7387\u6bd4\u666e\u901a\u6811\u8102\u5feb 20%\u201330%\u3002<\/li>\n    <li>\u5e74\u78e8\u635f\u7387&lt;1%\uff08\u666e\u901a\u6811\u8102 3%\u20135%\uff09\uff0c\u5bff\u547d\u66f4\u6301\u4e45\u3002<\/li>\n    <li>\u518d\u751f\u6548\u7387\u9ad8\uff0c\u53ef\u51cf\u5c11 30%\u201350% \u7684\u76d0\u8017\u4e0e\u5e9f\u6c34\u3002<\/li>\n    <li>\u901a\u8fc7 NSF\/FDA\u3001\u4e2d\u56fd MOH\u3001\u6b27\u76df REACH\/ResAP \u8ba4\u8bc1\u3002<\/li>\n  <\/ul>\n  <p style=\"font-size:.9em;color:#64748b;\">\u8f6f\u6c34\u673a\u51fa\u6c34\u662f\"\u751f\u6d3b\u7528\u6c34\"\u6539\u826f\uff0c<strong>\u4e0d\u5efa\u8bae\u76f4\u996e<\/strong>\uff1b\u76f4\u996e\u6c34\u8bf7\u8d70\u53a8\u4e0b RO \u672b\u7aef\u3002<\/p>\n\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u4e09\u3001\u963f\u5c14\u838e\u5a1c\u4e2d\u8f6f\u6838\u5fc3\u4f18\u52bf<\/h2>\n  <ul style=\"color:#334155;\">\n    <li><strong>\u8fdb\u53e3\u7f57\u95e8\u54c8\u65af\u6811\u8102<\/strong>\uff1a\u5927\u5bb9\u91cf\u586b\u5145\uff0c\u6027\u80fd\u7a33\u5b9a\u3001\u4ea4\u6362\u6548\u7387\u9ad8\u3002<\/li>\n    <li><strong>\u667a\u80fd\u63a7\u5236\u9600<\/strong>\uff1a\u65f6\u95f4+\u6d41\u91cf\u53cc\u63a7\uff0c\u7701\u6c34\u7701\u76d0\u3002<\/li>\n    <li><strong>1T \/ 2T \/ 3T \u673a\u578b<\/strong>\uff1a\u6ee1\u8db3\u4e0d\u540c\u6237\u578b\u7528\u6c34\u9700\u6c42\u3002<\/li>\n    <li><strong>\u63a8\u62c9\u5f0f\u65c1\u901a\u9600<\/strong>\uff1a\u81ea\u7531\u5207\u6362\uff0c\u68c0\u4fee\u4e0d\u505c\u6c34\u3002<\/li>\n    <li><strong>\u5e72\u76d0\u7bb1\u6a21\u5f0f<\/strong>\uff1a\u907f\u514d\u6ecb\u751f\u7ec6\u83cc\uff0c\u6ee4\u6599\u5bff\u547d\u66f4\u4e45\u3002<\/li>\n    <li><strong>\u5c45\u5bb6 \/ \u5ea6\u5047\u6a21\u5f0f<\/strong>\uff1a\u4e00\u952e\u5207\u6362\uff0c\u957f\u671f\u79bb\u5bb6\u4e0d\u6d6a\u8d39\u76d0\u3002<\/li>\n  <\/ul>\n\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u56db\u3001\u4e24\u5927\u7cfb\u5217\u4e0e\u578b\u53f7\u53c2\u6570<\/h2>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u7cfb\u5217\u4e00 \u00b7 \u65e5\u7acb\u6631\u4eab R \u7cfb\u5217\uff08R10 \/ R18 \/ R25\uff09<\/h3>\n  <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;max-width:340px;margin:14px 0;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r101825-zh.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a R10\/18\/25 \u4e09\u673a\u578b\u7ec4\u5408\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R10 \/ R18 \/ R25 \u4e09\u673a\u578b\u7ec4\u5408<\/div><\/div>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:14px 0;\">\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r10.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a R10\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R10 \u00b7 1.2T\/H<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r18.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a R18\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R18 \u00b7 2T\/H<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r25.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a R25\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R25 \u00b7 3T\/H<\/div><\/div>\n  <\/div>\n    <table style=\"width:100%;border-collapse:collapse;font-size:.9em;margin:12px 0;\">\n    <thead><tr style=\"background:#12314F;color:#fff;\"><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u578b\u53f7<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u5c3a\u5bf8(\u5bbd\u00d7\u539a\u00d7\u9ad8 mm)<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u65e5\u5e38\/\u6700\u5927\u6d41\u91cf<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u6811\u8102\u91cf<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u8fdb\u6c34\u538b\u529b<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">R10<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">300\u00d7400\u00d7550<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">1.2T \/ 2T<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">11 L<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">0.15\u20130.40 MPa<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">R18<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">300\u00d7400\u00d7780<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">2T \/ 4T<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">20 L<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">0.15\u20130.40 MPa<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">R25<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">300\u00d7400\u00d71080<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">3T \/ 6T<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">30 L<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">0.15\u20130.40 MPa<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:.85em;color:#94a3b8;\">\u4e09\u6b3e\u8fdb\u6c34\u6e29\u5ea6\u5747\u4e3a 5\u201338\u2103\uff1b\u8fc7\u6ee4\u4ecb\u8d28\u4e3a\u79bb\u5b50\u4ea4\u6362\u6811\u8102\uff1b\u8fdb\u6c34\u538b\u529b\u8303\u56f4\u53d6\u81ea\u5382\u5bb6\u5b89\u88c5\u4f7f\u7528\u8bf4\u660e\u4e66\uff08EST-R10 \/ EST-R18 \/ EST-R25 \/ EST-R50 \u4e09\u6b3e\u7edf\u4e00\u4e3a 0.15\u20130.40 MPa\uff09\u3002<\/p>\n  <p style=\"font-size:.92em;color:#475569;\">\u540c\u7cfb\u5217\u8fd8\u6709\u4e00\u6863\u66f4\u5927\u7684 <strong>EST-R50<\/strong>\uff1a\u6811\u8102 40 L\u3001\u76d0\u7bb1 64 L\u3001\u51c0\u6c34\u6d41\u91cf 67 L\/min\u3001\u518d\u751f\u5468\u671f 7.0 m\u00b3\u3001\u673a\u8eab 390\u00d7575\u00d71200 mm\uff0c\u8fdb\u51fa\u6c34\u53e3\u5f84 1\"BSPT\u3002\u591a\u70b9\u540c\u65f6\u7528\u6c34\u7684\u5927\u5b85\u53ef\u4ee5\u6309\u8fd9\u4e2a\u6863\u914d\u3002<\/p>\n  <p style=\"font-size:.92em;color:#64748b;\">\u53e6\u5916\uff0c\u8bf4\u660e\u4e66\u7ed9\u51fa\u7684\u518d\u751f\u5468\u671f\u662f\u6309\u539f\u6c34\u786c\u5ea6\u6298\u7b97\u7684\uff1aR10 \u7ea6 1.9 m\u00b3\u3001R18 \u7ea6 3.6 m\u00b3\u3001R25 \u7ea6 5.3 m\u00b3\u3001R50 \u7ea6 7.0 m\u00b3\u3002\u539f\u6c34\u786c\u5ea6\u9ad8\u4e8e 400 mg\/L \u7684\u5730\u533a\uff0c\u5468\u671f\u8981\u76f8\u5e94\u7f29\u77ed\u3002<\/p>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u7cfb\u5217\u4e8c \u00b7 \u963f\u6ce2\u7f57\u8fdb\u53e3 R \u7cfb\u5217\uff08R09 \/ R15 \/ R20\uff09<\/h3>\n  <p style=\"font-size:.92em;color:#475569;\">\u8fdb\u53e3\u76d8\u5f0f\u591a\u8def\u63a7\u5236\u9600\uff0c\u8fde\u7eed\u4f9b\u8f6f\u6c34\uff1b\u989d\u5b9a\u8fc7\u6c34\u603b\u91cf 10000m\u00b3\u3002<\/p>\n  <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;max-width:340px;margin:14px 0;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est091520-zh.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u963f\u6ce2\u7f57\u4e2d\u592e\u8f6f\u6c34\u673a R09\/15\/20 \u4e09\u673a\u578b\u7ec4\u5408\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R09 \/ R15 \/ R20 \u4e09\u673a\u578b\u7ec4\u5408<\/div><\/div>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:14px 0;\">\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r09.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u963f\u6ce2\u7f57\u4e2d\u592e\u8f6f\u6c34\u673a R09\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R09 \u00b7 1T<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r18.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u963f\u6ce2\u7f57\u4e2d\u592e\u8f6f\u6c34\u673a R15\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R15 \u00b7 2T<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r20.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u963f\u6ce2\u7f57\u4e2d\u592e\u8f6f\u6c34\u673a R20\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">R20 \u00b7 3T<\/div><\/div>\n  <\/div>\n  <table style=\"width:100%;border-collapse:collapse;font-size:.9em;margin:12px 0;\">\n    <thead><tr style=\"background:#12314F;color:#fff;\"><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u578b\u53f7<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u5916\u5f62(\u9ad8\u00d7\u957f\u00d7\u5bbd mm)<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u65e5\u5e38\/\u6700\u5927\u6d41\u91cf<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u6811\u8102\u91cf<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u9002\u7528\u6c34\u53e3<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">R09<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">553\u00d7432\u00d7298<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">1T \/ 2T<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">9.9 L<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">100\u2013150\u33a1(2\u6c34\u53e3)<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">R15<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">698\u00d7432\u00d7298<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">2T \/ 4T<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">10.5 L<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">150\u2013200\u33a1(4\u6c34\u53e3)<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">R20<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">1194\u00d7432\u00d7298<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">3T \/ 6T<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">23.2 L<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">200\u2013300\u33a1(6\u6c34\u53e3)<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:.85em;color:#94a3b8;\">\u963f\u6ce2\u7f57 R \u7cfb\u5217\u5de5\u4f5c\u6c34\u538b 0.20\u20130.60 MPa\u3001\u6c34\u6e29 4\u201338\u2103\uff1b\u4ee5\u4f9b\u6c34\u786c\u5ea6 170ppm \u6d4b\u7b97\uff0c\u5b9e\u9645\u6309\u5f53\u5730\u6c34\u8d28\u786c\u5ea6\u8c03\u6574\u3002<\/p>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a \u00b7 \u66f4\u591a\u5728\u552e\u5916\u89c2<\/h3>\n  <p style=\"font-size:.92em;color:#475569;\">\u9664\u4e0a\u6587 R \u7cfb\u5217\u5916\uff0c\u963f\u5c14\u838e\u5a1c\u4e2d\u8f6f\u8fd8\u6709 ES \u7ecf\u5178\u7cfb\u5217\u4e0e\u8d85\u6ee4\u673a\u578b\u5728\u552e\uff0c\u4ee5\u4e0b\u4e3a\u5404\u673a\u578b\u5916\u89c2\uff1a<\/p>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(180px,1fr));gap:12px;margin:14px 0;\">\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-es357-zh.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a ES3\/5\/7 \u7ec4\u5408\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">ES3 \/ ES5 \/ ES7 \u7ec4\u5408<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-es3.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a ES3\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">ES3<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-es5.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a ES5\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">ES5<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-es7.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\u673a ES7\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">ES7<\/div><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:10px;overflow:hidden;background:#fff;\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-cl-c200.jpg\" alt=\"\u963f\u5c14\u838e\u5a1c\u8d85\u6ee4\u673a C200\" style=\"width:100%;display:block;\" loading=\"lazy\"><div style=\"padding:8px 10px;font-size:.85em;color:#475569;\">\u8d85\u6ee4 C200<\/div><\/div>\n  <\/div>\n\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u4e94\u3001\u6309\u6237\u578b\u600e\u4e48\u9009<\/h2>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:12px;margin:16px 0;\">\n    <div style=\"border:1px solid #e2e8f0;border-radius:12px;padding:14px;background:#fff;\"><strong style=\"color:#12314F;\">\u516c\u5bd3 \/ \u5c0f\u6237<\/strong><br><span style=\"font-size:.88em;color:#475569;\">\u9009 1T \u6863\uff08R10 \/ R09\uff09\uff0c1\u20132 \u4e2a\u536b\u751f\u95f4\u591f\u7528\u3002<\/span><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:12px;padding:14px;background:#fff;\"><strong style=\"color:#12314F;\">\u5927\u5e73\u5c42 \/ \u590d\u5f0f<\/strong><br><span style=\"font-size:.88em;color:#475569;\">\u9009 2T \u6863\uff08R18 \/ R15\uff09\uff0c\u6709\u6d74\u7f38\u4e5f\u67d4\u987a\u3002<\/span><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:12px;padding:14px;background:#fff;\"><strong style=\"color:#12314F;\">\u522b\u5885 \/ \u5927\u5b85<\/strong><br><span style=\"font-size:.88em;color:#475569;\">\u9009 3T \u6863\uff08R25 \/ R20\uff09\uff0c\u591a\u70b9\u7528\u6c34\u4e0d\u964d\u8f6f\u3002<\/span><\/div>\n  <\/div>\n  <p style=\"font-size:.92em;color:#64748b;\">\u7ecf\u9a8c\u516c\u5f0f\uff1a1 \u5428 \/ 2 \u4e2a\u536b\u751f\u95f4\u30012 \u5428 \/ 4 \u4e2a\u536b\u751f\u95f4\u30013 \u5428 \/ 6 \u4e2a\u536b\u751f\u95f4\u3002\u5177\u4f53\u4ee5\u5b9e\u5730\u52d8\u6d4b\u7684\u5cf0\u503c\u6c34\u91cf\u4e3a\u51c6\u3002<\/p>\n  <!-- \u516d\u3001\u6c34\u538b\u4e0e\u65c1\u901a -->\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u516d\u3001\u88c5\u4e2d\u592e\u8f6f\u6c34\u673a\u4f1a\u4e0d\u4f1a\u8ba9\u5bb6\u91cc\u6c34\u538b\u53d8\u5c0f<\/h2>\n  <p style=\"color:#334155;\">\u5148\u8bf4\u7ed3\u8bba\uff1a<strong>\u6b63\u5e38\u5236\u6c34\u7684\u65f6\u5019\uff0c\u538b\u529b\u635f\u5931\u5f88\u5c0f\uff0c\u65e5\u5e38\u57fa\u672c\u611f\u89c9\u4e0d\u5230\u3002<\/strong>\u771f\u6b63\u4f1a\u8ba9\u5bb6\u91cc\u4eba\u89c9\u5f97\u6c34\u4e0d\u5bf9\u7684\uff0c\u53ea\u6709\u4e24\u79cd\u60c5\u51b5\u2014\u2014\u4e00\u662f\u5165\u6237\u6c34\u538b\u672c\u6765\u5c31\u4e0d\u591f\uff0c\u4e8c\u662f\u65c1\u901a\u9600\u88ab\u8bef\u5f00\u3002\u8fd9\u4e24\u4ef6\u4e8b\uff0c\u88c5\u4e4b\u524d\u80fd\u6d4b\uff0c\u88c5\u4e4b\u540e\u80fd\u67e5\u3002<\/p>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u2460 \u5382\u5bb6\u8981\u6c42\u7684\u8fdb\u6c34\u538b\u529b\u662f\u591a\u5c11<\/h3>\n  <table style=\"width:100%;border-collapse:collapse;font-size:.9em;margin:12px 0;\">\n    <thead><tr style=\"background:#12314F;color:#fff;\"><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u9879\u76ee<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u5382\u5bb6\u8981\u6c42<\/th><th style=\"border:1px solid #cbd5e1;padding:8px;\">\u8fbe\u4e0d\u5230\u4f1a\u600e\u6837<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u6700\u4f73\u4f9b\u6c34\u6c34\u538b<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">0.15\u20130.40 MPa<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u4f4e\u4e8e\u6216\u9ad8\u4e8e\u8fd9\u4e2a\u8303\u56f4\uff0c\u8981\u52a0\u88c5\u589e\u538b\u6cf5\u6216\u51cf\u538b\u9600<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u518d\u751f\u5438\u76d0\u6240\u9700\u6c34\u538b<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u4e0d\u4f4e\u4e8e 1.5 bar\uff08\u7ea6 0.15 MPa \/ 22 PSI\uff09<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u4f1a\u51fa\u73b0\u201d\u5438\u76d0\u4e0d\u8fde\u7eed\u201d\uff0c\u518d\u751f\u505a\u4e0d\u5f7b\u5e95\uff0c\u51fa\u6c34\u91cd\u65b0\u53d8\u786c<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u9002\u7528\u6c34\u6e29<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">5\u201338\u2103<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u4e0d\u8981\u8f6f\u5316\u9ad8\u4e8e 38\u2103 \u6216\u4f4e\u4e8e 5\u2103 \u7684\u6c34<\/td><\/tr>\n      <tr><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u8fdb\u6c34\u786c\u5ea6<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u5efa\u8bae 400 mg\/L \u4ee5\u5185<\/td><td style=\"border:1px solid #e2e8f0;padding:8px;\">\u786c\u5ea6\u66f4\u9ad8\u7684\u5730\u533a\uff0c\u673a\u578b\u4e0e\u518d\u751f\u5468\u671f\u8981\u53e6\u884c\u8bc4\u4f30<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"font-size:.85em;color:#94a3b8;\">\u4ee5\u4e0a\u4e3a\u6631\u4eab\u7cfb\u5217\u4e2d\u592e\u8f6f\u6c34\u673a\uff08EST-R10 \/ EST-R18 \/ EST-R25 \/ EST-R50\uff09\u5b89\u88c5\u4f7f\u7528\u8bf4\u660e\u4e66\u6807\u6ce8\u503c\u3002<\/p>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u2461 \u6c34\u538b\u4e0d\u591f\uff0c\u4f1a\u5148\u5192\u51fa\u8fd9\u51e0\u4e2a\u75c7\u72b6<\/h3>\n  <ul style=\"color:#334155;font-size:.94em;\">\n    <li><strong>\u5438\u76d0\u4e0d\u8fde\u7eed<\/strong>\u2014\u2014\u8bf4\u660e\u4e66\u628a\u539f\u56e0\u76f4\u63a5\u5199\u6210\u201d\u8fdb\u6c34\u538b\u529b\u4f4e\u201d\uff0c\u89e3\u51b3\u529e\u6cd5\u662f\u628a\u8fdb\u6c34\u538b\u529b\u7ef4\u6301\u5728 1.5 bar\uff0822 PSI\uff09\u4ee5\u4e0a\u3002<\/li>\n    <li><strong>\u518d\u751f\u5b8c\u6c34\u8fd8\u662f\u504f\u786c<\/strong>\u2014\u2014\u53ef\u80fd\u662f\u518d\u751f\u7a0b\u5e8f\u8bbe\u7f6e\u4e0d\u5f53\uff0c\u4e5f\u53ef\u80fd\u662f\u65c1\u901a\u9600\u6709\u6cc4\u6f0f\u3001\u6216\u8005\u505c\u5728\u65c1\u901a\u4f4d\u7f6e\u3002<\/li>\n    <li><strong>\u9762\u677f\u4e0a\u7684\u6d41\u91cf\u6307\u793a\u4e0d\u95ea\u52a8<\/strong>\u2014\u2014\u8bf4\u660e\u4e66\u539f\u56e0\u680f\u5199\u7684\u6b63\u662f\u201d\u65c1\u901a\u9600\u5904\u4e8e\u65c1\u901a\u4f4d\u7f6e\u201d\uff0c\u628a\u65c1\u901a\u5173\u56de\u53bb\u5c31\u597d\u3002<\/li>\n  <\/ul>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u2462 \u65c1\u901a\u9600\u5230\u5e95\u662f\u5e72\u4ec0\u4e48\u7684<\/h3>\n  <p style=\"color:#334155;\">\u8bf4\u660e\u4e66\u539f\u8bdd\uff1a<strong>\u672c\u7cfb\u7edf\u81ea\u5e26\u65c1\u901a\u9600<\/strong>\uff0c\u53ef\u628a\u8bbe\u5907\u4e0e\u7ed9\u6c34\u7cfb\u7edf\u9694\u5f00\uff0c\u5728\u8bbe\u5907\u505a\u65e5\u5e38\u7ef4\u62a4\u6216\u4fdd\u517b\u65f6<strong>\u4e0d\u4e2d\u65ad\u4f9b\u6c34<\/strong>\u3002<\/p>\n  <div style=\"display:grid;gap:10px;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));margin:12px 0;\">\n    <div style=\"border:1px solid #e2e8f0;border-radius:12px;padding:14px;background:#fff;\"><strong style=\"color:#12314F;\">\u5411\u5185\u63a8 \u00b7 \u6253\u5f00\u65c1\u901a<\/strong><br><span style=\"font-size:.88em;color:#475569;\">\u6c34\u7ed5\u8fc7\u6811\u8102\u7f50\uff0c\u51fa\u6c34\u53e3\u8d70\u7684\u662f\u539f\u6c34\u3002\u68c0\u4fee\u3001\u6216\u8005\u8fd9\u4e00\u6bb5\u4e0d\u5fc5\u7528\u8f6f\u6c34\u7684\u65f6\u5019\uff0c\u624d\u63a8\u5230\u8fd9\u4e2a\u4f4d\u7f6e\u3002<\/span><\/div>\n    <div style=\"border:1px solid #e2e8f0;border-radius:12px;padding:14px;background:#fff;\"><strong style=\"color:#12314F;\">\u5411\u5916\u62c9 \u00b7 \u5173\u95ed\u65c1\u901a<\/strong><br><span style=\"font-size:.88em;color:#475569;\">\u6c34\u7167\u5e38\u7a7f\u8fc7\u6811\u8102\u7f50\uff0c\u51fa\u6765\u7684\u662f\u8f6f\u6c34\u3002\u5e73\u65f6\u5c31\u505c\u5728\u8fd9\u4e2a\u4f4d\u7f6e\u3002<\/span><\/div>\n  <\/div>\n  <p style=\"font-size:.92em;color:#64748b;\">\u6709\u4e00\u70b9\u8981\u8bf4\u660e\u767d\uff1a\u8fd9\u4e2a\u65c1\u901a\u9600\u662f<strong>\u624b\u52a8\u63a8\u62c9<\/strong>\u7684\uff0c\u4e0d\u662f\u81ea\u52a8\u5207\u6362\u3002\u6240\u4ee5\u88c5\u5b8c\u4e4b\u540e\uff0c\u5224\u65ad\u5bb6\u91cc\u51fa\u6c34\u662f\u4e0d\u662f\u8f6f\u7684\uff0c\u5148\u8981\u770b\u7684\u5c31\u662f\u5b83\u6709\u6ca1\u6709\u505c\u5728\u5173\u95ed\u4f4d\u7f6e\u3002\u65c1\u901a\u4e00\u65e6\u88ab\u8bef\u5f00\uff0c\u6c34\u7ed5\u8fc7\u6811\u8102\u7f50\u76f4\u63a5\u8fdb\u5bb6\uff0c\u51fa\u6765\u7684\u5c31\u662f\u786c\u6c34\u2014\u2014\u8fd9\u662f\u771f\u5b9e\u552e\u540e\u91cc\u201d\u8f6f\u6c34\u673a\u597d\u50cf\u6ca1\u6548\u679c\u201d\u6700\u5e38\u89c1\u7684\u539f\u56e0\u4e4b\u4e00\u3002<\/p>\n  <div style=\"margin:12px 0;padding:14px 16px;border:1px solid #e2e8f0;border-left:4px solid #E8541E;border-radius:10px;background:#fff;font-size:.92em;color:#475569;\">\n    <strong style=\"color:#12314F;\">\ud83d\udcc4 \u771f\u5b9e\u552e\u540e\u5b9e\u5f55<\/strong>\uff1a\u6210\u90fd\u65b0\u6d25\u4e9a\u7279\u5170\u8482\u65af\u4e00\u4f4d\u4e1a\u4e3b\u9047\u5230\u201d\u8f6f\u6c34\u673a\u6ca1\u6548\u679c\u201d\uff0c\u6280\u672f\u5458\u6309\u201d\u7535\u6e90 \u2192 \u76d0\u7bb1 \u2192 \u65c1\u901a\u9600 \u2192 \u6811\u8102\u201d\u7684\u987a\u5e8f\u9010\u9879\u6392\u67e5\uff0c\u5176\u4e2d\u4e00\u9879\u67e5\u7684\u5c31\u662f\u65c1\u901a\u9600\u6709\u6ca1\u6709\u88ab\u8bef\u5f00\u3002\u5168\u8fc7\u7a0b\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13007\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\u6210\u90fd\u65b0\u6d25\u4e9a\u7279\u5170\u8482\u65af\u00b7\u8f6f\u6c34\u673a\u65e0\u6548\u679c\u5b9e\u5f55<\/a>\u3002\n  <\/div>\n\n  <h3 style=\"color:#12314F;margin-top:24px;\">\u2463 \u88c5\u4fee\u9636\u6bb5\u8981\u505a\u7684\u4e09\u4ef6\u4e8b<\/h3>\n  <ul style=\"color:#334155;font-size:.94em;\">\n    <li><strong>\u88c5\u4e4b\u524d\u5148\u91cf\u6c34\u538b\u3002<\/strong>\u7528\u538b\u529b\u8868\u6d4b\u5165\u6237\u81ea\u6765\u6c34\u538b\u529b\uff0c\u770b\u662f\u5426\u843d\u5728 0.15\u20130.40 MPa\u3002\u4f4e\u4e86\u88c5\u589e\u538b\u6cf5\u3001\u9ad8\u4e86\u88c5\u51cf\u538b\u9600\uff0c\u8bf4\u660e\u4e66\u5bf9\u8fd9\u4e24\u79cd\u60c5\u51b5\u90fd\u5199\u660e\u4e86\u5904\u7406\u529e\u6cd5\u3002\u8fd9\u4e2a\u6d3b\u513f\u6211\u4eec\u52d8\u6d4b\u65f6\u4e00\u5e76\u505a\u3002<\/li>\n    <li><strong>\u8fdb\u51fa\u6c34\u7ba1\u4e4b\u95f4\u7559\u65c1\u901a\u7ba1\u8def\u3002<\/strong>\u8bf4\u660e\u4e66\u5efa\u8bae\u8fdb\u51fa\u6c34\u53e3\u5404\u88c5\u4e00\u4e2a\u624b\u52a8\u9600\u95e8\uff0c\u8fdb\u51fa\u6c34\u7ba1\u4e4b\u95f4\u7559\u65c1\u901a\u9600\u6216\u65c1\u901a\u7ba1\u8def\uff0c\u68c0\u4fee\u65f6\u4e0d\u5f71\u54cd\u5bb6\u91cc\u6b63\u5e38\u7528\u6c34\u3002<\/li>\n    <li><strong>\u88c5\u597d\u540e\u5934\u4e24\u5929\u7559\u610f\u63a5\u5934\u3002<\/strong>\u81ea\u6765\u6c34\u538b\u529b\u672c\u8eab\u4f1a\u53d8\uff08\u4e00\u822c\u591c\u95f4\u6bd4\u767d\u5929\u9ad8\uff09\uff0c\u6240\u4ee5\u521a\u88c5\u597d\u8fd0\u884c\u7684\u524d\u4e24\u5929\uff0c\u8981\u7559\u610f\u5404\u5904\u8fde\u63a5\u6709\u6ca1\u6709\u6e17\u6f0f\u3002<\/li>\n  <\/ul>\n  <p style=\"font-size:.92em;color:#64748b;\">\u518d\u8865\u4e00\u53e5\uff1a\u4e2d\u592e\u8f6f\u6c34\u673a\u4e0d\u8d1f\u8d23\u201d\u63d0\u538b\u201d\uff0c\u5b83\u7ba1\u7684\u662f\u628a\u6c34\u53d8\u8f6f\u3002\u5982\u679c\u60a8\u5bb6\u672c\u8eab\u6c34\u538b\u504f\u4f4e\uff08\u6bd4\u5982\u9876\u5c42\u3001\u8001\u65e7\u5c0f\u533a\u9ad8\u533a\uff09\uff0c\u6211\u4eec\u4f1a\u628a\u589e\u538b\u8fd9\u4ef6\u4e8b\u4e00\u5e76\u7b97\u8fdb\u65b9\u6848\u91cc\uff0c\u800c\u4e0d\u662f\u6307\u671b\u8f6f\u6c34\u673a\u987a\u4fbf\u89e3\u51b3\u3002<\/p>\n\n  <h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u4e03\u3001\u4e3a\u4ec0\u4e48\u8d8a\u6765\u8d8a\u591a\u4eba\u9009\u8f6f\u6c34<\/h2>\n  <ul style=\"color:#334155;font-size:.94em;\">\n    <li>\u6d17\u7897\u673a\u3001\u6b27\u6807\u82b1\u6d12\uff08\u6c49\u65af\u683c\u96c5\u7b49\uff09\u3001\u667a\u80fd\u52a0\u70ed\u55b7\u6dcb\u9a6c\u6876\u7684\u8bf4\u660e\u4e66\uff0c\u90fd\u660e\u786e\u8981\u6c42\"\u8f6f\u6c34\"\u6c34\u6e90\u3002<\/li>\n    <li>\u8f6f\u6c34\u6d17\u6fa1\u540e\u76ae\u80a4\u987a\u6ed1\uff0c\u88ab\u79f0\u4e3a\"\u7f8e\u5bb9\u6c34\"\u3002<\/li>\n    <li>\u8863\u7269\u84ec\u677e\u67d4\u8f6f\uff0c\u7701\u6d17\u6da4\u5242\u66f4\u73af\u4fdd\u3002<\/li>\n    <li>\u73bb\u7483\u3001\u9910\u5177\u51b2\u6d17\u540e\u65e0\u6c34\u57a2\u6591\uff0c\u5149\u4eae\u5982\u65b0\u3002<\/li>\n  <\/ul>\n\n  <div style=\"margin:16px 0;padding:14px 16px;border:1px dashed #E8541E;border-radius:10px;background:#fff7f2;font-size:.92em;color:#475569;line-height:1.7;\">\n    <strong style=\"color:#12314F;\">\ud83d\udcb0 \u4ef7\u683c\u600e\u4e48\u7b97<\/strong>\uff1a\u4e2d\u592e\u8f6f\u6c34\u673a\u4e0d\u597d\u62a5\u4e00\u4e2a\u7edf\u4e00\u6570\u5b57\u2014\u2014\u5b83\u8ddf\u6237\u578b\u3001\u536b\u751f\u95f4\u6570\u91cf\u3001\u7ba1\u53e3\u4f4d\u7f6e\u3001\u8981\u4e0d\u8981\u6539\u7ba1\u90fd\u6709\u5173\u7cfb\u3002\u6211\u4eec\u4f1a\u5728\u514d\u8d39\u4e0a\u95e8\u65f6\u5148\u6d4b\u6c34\u8d28\u786c\u5ea6\u3001\u91cf\u597d\u7ba1\u53e3\uff0c\u518d\u51fa\u4e00\u4efd\u5b8c\u6574\u62a5\u4ef7\uff08\u542b\u4e3b\u673a + \u57fa\u7840\u5b89\u88c5\uff0c\u4e0d\u542b\u5168\u5c4b\u7ba1\u8def\u6539\u9020\uff09\u3002\u5982\u679c\u8981\u505a\u5b8c\u6574\u7684\u5168\u5c4b\u51c0\u6c34\u4e94\u4ef6\u5957\uff0c\u9700\u8981\u628a\u524d\u7f6e\u8fc7\u6ee4\u5668 \/ \u4e2d\u592e\u51c0\u6c34\u673a \/ \u4e2d\u592e\u8f6f\u6c34\u673a \/ \u53a8\u4e0b\u672b\u7aef \/ \u7ba1\u7ebf\u673a\u4e00\u8d77\u6d4b\u7b97\uff0c\u8be6\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13015\" target=\"_blank\" rel=\"noopener\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\u5168\u5c4b\u51c0\u6c34\u7cfb\u7edf<\/a>\u3002\u6700\u7ec8\u4ef7\u683c\u4ee5\u73b0\u573a\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\u3002\n  <\/div>\n\n<h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u516b\u3001\u5e38\u89c1\u95ee\u9898\uff08FAQ\uff09<\/h2>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u8f6f\u6c34\u80fd\u76f4\u63a5\u559d\u5417\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u4e0d\u5efa\u8bae\u3002\u8f6f\u6c34\u673a\u53ea\u53bb\u9664\u9499\u9541\uff0c\u672a\u53bb\u9664\u7ec6\u83cc\/\u91cd\u91d1\u5c5e\uff1b\u76f4\u996e\u6c34\u8bf7\u8d70\u53a8\u4e0b RO \u672b\u7aef\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u8f6f\u6c34\u673a\u8d39\u76d0\u8d39\u6c34\u5417\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u963f\u5c14\u838e\u5a1c\u91c7\u7528\u65f6\u95f4+\u6d41\u91cf\u53cc\u63a7\u4e0e\u9ad8\u6548\u6811\u8102\uff0c\u6309\u9700\u518d\u751f\uff0c\u6bd4\u4f20\u7edf\u673a\u578b\u7701\u76d0 30%\u201350%\u3001\u7701\u6c34\u660e\u663e\uff1b\u5e72\u76d0\u7bb1\u6a21\u5f0f\u4e5f\u51cf\u5c11\u7ec6\u83cc\u6ecb\u751f\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u4e2d\u51c0\u548c\u4e2d\u8f6f\u5fc5\u987b\u5148\u88c5\u54ea\u4e2a\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u6c34\u6d41\u987a\u5e8f\uff1a\u524d\u7f6e\u2192\u4e2d\u51c0\u2192\u4e2d\u8f6f\u2192\u53a8\u4e0b\u2192\u7ba1\u7ebf\u673a\u3002\u4e2d\u51c0\u5728\u524d\u53bb\u4f59\u6c2f\u3001\u4fdd\u62a4\u4e2d\u8f6f\u6811\u8102\uff0c\u4e2d\u8f6f\u5728\u540e\u9664\u9499\u9541\uff0c\u987a\u5e8f\u4e0d\u80fd\u53cd\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u6210\u90fd\u88c5\u4e2d\u592e\u8f6f\u6c34\u673a\u5927\u6982\u591a\u5c11\u94b1\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u8ddf\u6237\u578b\u3001\u536b\u751f\u95f4\u6570\u91cf\u3001\u7ba1\u53e3\u4f4d\u7f6e\u548c\u8981\u4e0d\u8981\u6539\u7ba1\u90fd\u6709\u5173\u7cfb\uff0c\u4e0d\u597d\u7ed9\u4e00\u4e2a\u7edf\u4e00\u6570\u5b57\u3002\u6211\u4eec\u4f1a\u5728\u514d\u8d39\u4e0a\u95e8\u65f6\u5148\u6d4b\u6c34\u8d28\u786c\u5ea6\u3001\u91cf\u597d\u7ba1\u53e3\uff0c\u518d\u51fa\u4e00\u4efd\u5b8c\u6574\u62a5\u4ef7\uff08\u542b\u4e3b\u673a + \u57fa\u7840\u5b89\u88c5\uff0c\u4e0d\u542b\u5168\u5c4b\u7ba1\u8def\u6539\u9020\uff09\u3002\u5982\u679c\u8981\u914d\u9f50\u5168\u5c4b\u51c0\u6c34\u4e94\u4ef6\u5957\uff0c\u9700\u628a\u524d\u7f6e\u8fc7\u6ee4\u5668 \/ \u4e2d\u592e\u51c0\u6c34\u673a \/ \u4e2d\u592e\u8f6f\u6c34\u673a \/ \u53a8\u4e0b\u672b\u7aef \/ \u7ba1\u7ebf\u673a\u4e00\u8d77\u6d4b\u7b97\uff0c\u8be6\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13015\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\u5168\u5c4b\u51c0\u6c34\u7cfb\u7edf<\/a>\u3002\u6700\u7ec8\u4ef7\u683c\u4ee5\u73b0\u573a\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u5df2\u7ecf\u88c5\u4fee\u5b8c\u8fd8\u80fd\u88c5\u4e2d\u592e\u8f6f\u6c34\u673a\u5417\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u53ef\u4ee5\u3002\u4e2d\u592e\u8f6f\u6c34\u88c5\u5728\u5165\u6237\u603b\u7ba1\u6216\u8bbe\u5907\u9633\u53f0\uff0c\u9700\u9884\u7559\u6392\u6c61\u53e3\u4e0e\u7535\u6e90\uff1b\u88c5\u4fee\u5b8c\u52a0\u88c5\u4e3b\u8981\u770b\u7ba1\u53e3\u4f4d\u7f6e\u4e0e\u8bbe\u5907\u7a7a\u95f4\uff0c\u90e8\u5206\u6237\u578b\u9700\u8d70\u660e\u7ba1\u6216\u5c40\u90e8\u6539\u9020\u3002\u5efa\u8bae\u5148\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u786e\u8ba4\u843d\u4f4d\u4e0e\u662f\u5426\u9700\u8865\u7ba1\uff0c\u518d\u51fa\u65b9\u6848\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u8f6f\u6c34\u5bf9\u5730\u6696 \/ \u6696\u6c14\u7247\u6709\u5f71\u54cd\u5417\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u8f6f\u6c34\u51cf\u5c11\u5730\u6696\u3001\u6696\u6c14\u7247\u53ca\u6d89\u6c34\u7ba1\u8def\u7684\u6c34\u57a2\uff0c\u63d0\u5347\u6362\u70ed\u6548\u7387\u3001\u5ef6\u957f\u5bff\u547d\uff0c\u5bf9\u91c7\u6696\u7cfb\u7edf\u662f\u52a0\u5206\u9879\u3002\u4f46\u91c7\u6696\u7089\u7684\u6362\u70ed\u4fa7\u8d70\u7684\u662f\u72ec\u7acb\u91c7\u6696\u5faa\u73af\u6c34\uff0c\u4e0e\u8f6f\u6c34\u751f\u6d3b\/\u996e\u6c34\u5206\u5c5e\u4e24\u5957\u7cfb\u7edf\u2014\u2014\u8f6f\u6c34\u4e3b\u8981\u4fdd\u62a4\u9f99\u5934\u3001\u82b1\u6d12\u3001\u70ed\u6c34\u5668\u7b49\u6d89\u6c34\u5bb6\u7535\uff0c\u4e0d\u76f4\u63a5\u8fdb\u5165\u91c7\u6696\u7089\u6362\u70ed\u4fa7\u3002\u88c5\u4fee\u65f6\u628a\u201c\u8f6f\u6c34 + \u91c7\u6696\u201d\u7edf\u7b79\u89c4\u5212\uff0c\u6548\u679c\u6700\u597d\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u88c5\u4e2d\u592e\u8f6f\u6c34\u673a\u4f1a\u4e0d\u4f1a\u8ba9\u5bb6\u91cc\u6c34\u538b\u53d8\u5c0f\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u6b63\u5e38\u5236\u6c34\u65f6\u538b\u529b\u635f\u5931\u5f88\u5c0f\uff0c\u65e5\u5e38\u57fa\u672c\u611f\u89c9\u4e0d\u5230\u3002\u8981\u7559\u610f\u4e24\u4ef6\u4e8b\uff1a\u4e00\u662f\u5165\u6237\u6c34\u538b\u8981\u843d\u5728 0.15\u20130.40 MPa \u4e4b\u95f4\uff08\u5382\u5bb6\u8981\u6c42\uff0c\u4f4e\u4e86\u8981\u52a0\u589e\u538b\u6cf5\u3001\u9ad8\u4e86\u8981\u52a0\u51cf\u538b\u9600\uff09\uff1b\u4e8c\u662f\u518d\u751f\u5438\u76d0\u8981\u6c42\u8fdb\u6c34\u538b\u529b\u4e0d\u4f4e\u4e8e 1.5 bar\uff0c\u538b\u529b\u4e0d\u591f\u4f1a\u51fa\u73b0\u201c\u5438\u76d0\u4e0d\u8fde\u7eed\u201d\uff0c\u518d\u751f\u6548\u679c\u5c31\u6253\u6298\u6263\u3002\u88c5\u4e4b\u524d\u6211\u4eec\u4f1a\u7528\u538b\u529b\u8868\u5b9e\u6d4b\u4e00\u4e0b\u3002<\/p>\n<\/details>\n\n<details style=\"border:1px solid #e2e8f0;border-radius:10px;padding:12px;margin:10px 0;background:#fff;\">\n  <summary style=\"cursor:pointer;font-weight:600;color:#12314F;\">\u65c1\u901a\u9600\u5728\u54ea\u513f\uff1f\u600e\u4e48\u77e5\u9053\u5b83\u6709\u6ca1\u6709\u88ab\u8bef\u5f00\uff1f<\/summary>\n  <p style=\"margin:10px 0 0;color:#475569;font-size:.94em;\">\u65c1\u901a\u9600\u5728\u673a\u5668\u4e0a\uff0c\u968f\u673a\u914d\u597d\u3001\u51fa\u5382\u5df2\u88c5\u597d\u3002\u5411\u5185\u63a8\u662f\u6253\u5f00\u65c1\u901a\uff08\u51fa\u539f\u6c34\uff09\uff0c\u5411\u5916\u62c9\u662f\u5173\u95ed\u65c1\u901a\uff08\u51fa\u8f6f\u6c34\uff09\uff0c\u5e73\u65f6\u5e94\u8be5\u505c\u5728\u5173\u95ed\u4f4d\u7f6e\u3002\u5982\u679c\u53d1\u73b0\u6c34\u53c8\u53d1\u6da9\u3001\u82b1\u6d12\u53c8\u7ed3\u57a2\uff0c\u5148\u770b\u4e00\u773c\u65c1\u901a\u9600\u2014\u2014\u8bef\u5f00\u662f\u201c\u8f6f\u6c34\u673a\u597d\u50cf\u6ca1\u6548\u679c\u201d\u6700\u5e38\u89c1\u7684\u539f\u56e0\u4e4b\u4e00\uff0c\u53ef\u53c2\u8003 <a href=\"https:\/\/longmai-nt.com\/?page_id=13007\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\u6210\u90fd\u65b0\u6d25\u4e9a\u7279\u5170\u8482\u65af\u00b7\u8f6f\u6c34\u673a\u65e0\u6548\u679c\u5b9e\u5f55<\/a>\u3002<\/p>\n<\/details>\n\n<h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u76f8\u5173\u9605\u8bfb<\/h2>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(150px,1fr));gap:12px;margin:14px 0;\">\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13007\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u8f6f\u6c34\u673a\u65e0\u6548\u679c\u5b9e\u5f55<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u65c1\u901a\u8bef\u5f00\u771f\u5b9e\u6848\u4f8b<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=3421\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u963f\u5c14\u838e\u5a1c\u51c0\u6c34\u77e5\u8bc6\u5e95\u5ea7<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u5168\u5c4b\u51c0\u6c34\u4e94\u4ef6\u5957\u603b\u89c8<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13013\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u4e2d\u592e\u51c0\u6c34\u673a\uff08\u4e2d\u51c0\uff09<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u53bb\u4f59\u6c2f<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13017\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u53a8\u4e0b\u51c0\u6c34\u673a\uff08\u672b\u7aef\uff09<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">RO\u76f4\u996e<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13015\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u5168\u5c4b\u51c0\u6c34\u7cfb\u7edf<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u4e94\u4ef6\u5957\u65b9\u6848<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13019\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u524d\u7f6e\u8fc7\u6ee4\u5668<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u5165\u6237\u7b2c\u4e00\u5173<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13021\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u7ba1\u7ebf\u673a<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u5373\u70ed\u996e\u6c34<\/div><\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=1849\" style=\"display:block;padding:14px 12px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;text-align:center;\"><div style=\"font-weight:600;line-height:1.4;\">\u5168\u5c4b\u51c0\u6c34\u901a\u7528\u77e5\u8bc6<\/div><div style=\"font-size:.8em;color:#94a3b8;margin-top:4px;\">\u79d1\u666e\u805a\u5408\u9875<\/div><\/a>\n<\/div>\n\n<h2 style=\"color:#12314F;border-left:5px solid #E8541E;padding-left:12px;margin-top:32px;\">\u6210\u90fd\u95e8\u5e97\u4e0e\u670d\u52a1\uff08\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff09<\/h2>\n<p style=\"font-size:.94em;color:#475569;\">\u963f\u5c14\u838e\u5a1c\u7531<strong>\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8<\/strong>\uff08\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u670d\u52a1\u5546\uff09\u672c\u5730\u670d\u52a1\uff1a\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u786c\u5ea6\u3001\u91cf\u7ba1\u53e3\uff0c\u51fa\u5177\u5168\u5c4b\u51c0\u6c34\u642d\u914d\u65b9\u6848\u4e0e\u62a5\u4ef7\u3002<\/p>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:14px;margin:16px 0;\">\n  <div style=\"border:1px solid #e2e8f0;border-radius:12px;overflow:hidden;background:#fff;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\" style=\"width:100%;display:block;height:170px;object-fit:cover;\" loading=\"lazy\">\n    <div style=\"padding:14px 16px;\">\n      <div style=\"font-weight:700;color:#12314F;\">\u5357\u5bcc\u68ee \u00b7 \u9ad8\u65b0\u5e97<\/div>\n      <p style=\"font-size:.86em;color:#475569;margin:8px 0;\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/p>\n      <p style=\"font-size:.86em;color:#475569;margin:4px 0;\">\u70ed\u7ebf <a href=\"tel:02886131795\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">028-86131795<\/a><\/p>\n      <p style=\"font-size:.86em;color:#475569;margin:4px 0;\">\u8303\u7ecf\u7406 133-9819-8375 \uff0f \u9ec4\u7ecf\u7406 158-2848-9188\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/p>\n      <p style=\"font-size:.86em;margin:8px 0 0;\"><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107\" target=\"_blank\" rel=\"noopener\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\ud83d\udccd \u9ad8\u5fb7\u5bfc\u822a\u5230\u8fd9\u91cc<\/a><\/p>\n    <\/div>\n  <\/div>\n  <div style=\"border:1px solid #e2e8f0;border-radius:12px;overflow:hidden;background:#fff;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u6210\u534e\u5e97\" style=\"width:100%;display:block;height:170px;object-fit:cover;\" loading=\"lazy\">\n    <div style=\"padding:14px 16px;\">\n      <div style=\"font-weight:700;color:#12314F;\">\u5317\u5bcc\u68ee \u00b7 \u6210\u534e\u5e97<\/div>\n      <p style=\"font-size:.86em;color:#475569;margin:8px 0;\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/p>\n      <p style=\"font-size:.86em;color:#475569;margin:4px 0;\">\u70ed\u7ebf <a href=\"tel:02865272586\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">028-65272586<\/a><\/p>\n      <p style=\"font-size:.86em;color:#475569;margin:4px 0;\">\u9ec4\u7ecf\u7406 158-2848-9188\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/p>\n      <p style=\"font-size:.86em;margin:8px 0 0;\"><a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108\" target=\"_blank\" rel=\"noopener\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\ud83d\udccd \u9ad8\u5fb7\u5bfc\u822a\u5230\u8fd9\u91cc<\/a><\/p>\n    <\/div>\n  <\/div>\n<\/div>\n<p style=\"font-size:.88em;color:#64748b;\">\u552e\u540e\u4e13\u7ebf\uff1a028-65272586 \uff5c \u5b98\u7f51\uff1a<a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" rel=\"noopener\" style=\"color:#E8541E;text-decoration:none;\">longmai-nt.com<\/a><\/p>\n\n<div style=\"margin:28px 0 8px;padding:18px 20px;border:1px solid #E8541E;border-radius:12px;background:#fff7f2;\">\n  <p style=\"margin:0;color:#12314F;font-weight:600;\">\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u963f\u5c14\u838e\u5a1c\u6388\u6743\u670d\u52a1\u5546<\/p>\n  <p style=\"margin:6px 0 0;font-size:.92em;color:#475569;\">\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u786c\u5ea6\u3001\u91cf\u7ba1\u53e3\uff0c\u7ed9\u51fa\u4e2d\u51c0+\u4e2d\u8f6f+\u672b\u7aef\u7684\u5168\u5c4b\u642d\u914d\u65b9\u6848\u3002\u95e8\u5e97\uff1a\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97 \/ \u5317\u5bcc\u68ee\u6210\u534e\u5e97\u3002<\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u4e2d\u592e\u8f6f\u6c34\u673a\uff08\u4e1a\u5185\u79f0\u4e2d\u8f6f\uff09\u662f\u963f\u5c14\u838e\u5a1c\u5168\u5c4b\u51c0 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13011","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff1f\u4e2d\u592e\u8f6f\u6c34\u53bb\u9664\u6c34\u57a2\u9499\u9541\uff0c\u5475\u62a4\u808c\u80a4\u4e0e\u70ed\u6c34\u5668\u3001\u82b1\u6d12\uff1b\u963f\u5c14\u838e\u5a1c\u65e5\u7acb\u6631\u4eab\/\u963f\u6ce2\u7f57\u7cfb\u5217\uff0c1T\/2T\/3T \u6309\u6237\u578b\u9009\uff0c\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u51fa\u65b9\u6848\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=13011\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff1f\u4e2d\u592e\u8f6f\u6c34\u53bb\u9664\u6c34\u57a2\u9499\u9541\uff0c\u5475\u62a4\u808c\u80a4\u4e0e\u70ed\u6c34\u5668\u3001\u82b1\u6d12\uff1b\u963f\u5c14\u838e\u5a1c\u65e5\u7acb\u6631\u4eab\/\u963f\u6ce2\u7f57\u7cfb\u5217\uff0c1T\/2T\/3T \u6309\u6237\u578b\u9009\uff0c\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u51fa\u65b9\u6848\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=13011\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-03T05:30:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r101825-zh.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011\",\"name\":\"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/aesn-zyrsj-est-r101825-zh.jpg\",\"datePublished\":\"2026-09-22T08:01:51+00:00\",\"dateModified\":\"2026-11-03T05:30:02+00:00\",\"description\":\"\u6210\u90fd\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff1f\u4e2d\u592e\u8f6f\u6c34\u53bb\u9664\u6c34\u57a2\u9499\u9541\uff0c\u5475\u62a4\u808c\u80a4\u4e0e\u70ed\u6c34\u5668\u3001\u82b1\u6d12\uff1b\u963f\u5c14\u838e\u5a1c\u65e5\u7acb\u6631\u4eab\\\/\u963f\u6ce2\u7f57\u7cfb\u5217\uff0c1T\\\/2T\\\/3T \u6309\u6237\u578b\u9009\uff0c\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u51fa\u65b9\u6848\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/aesn-zyrsj-est-r101825-zh.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/aesn-zyrsj-est-r101825-zh.jpg\",\"width\":2400,\"height\":1552},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13011#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff1f\u4e2d\u592e\u8f6f\u6c34\u53bb\u9664\u6c34\u57a2\u9499\u9541\uff0c\u5475\u62a4\u808c\u80a4\u4e0e\u70ed\u6c34\u5668\u3001\u82b1\u6d12\uff1b\u963f\u5c14\u838e\u5a1c\u65e5\u7acb\u6631\u4eab\/\u963f\u6ce2\u7f57\u7cfb\u5217\uff0c1T\/2T\/3T \u6309\u6237\u578b\u9009\uff0c\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u51fa\u65b9\u6848\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=13011","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff1f\u4e2d\u592e\u8f6f\u6c34\u53bb\u9664\u6c34\u57a2\u9499\u9541\uff0c\u5475\u62a4\u808c\u80a4\u4e0e\u70ed\u6c34\u5668\u3001\u82b1\u6d12\uff1b\u963f\u5c14\u838e\u5a1c\u65e5\u7acb\u6631\u4eab\/\u963f\u6ce2\u7f57\u7cfb\u5217\uff0c1T\/2T\/3T \u6309\u6237\u578b\u9009\uff0c\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u51fa\u65b9\u6848\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=13011","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-03T05:30:02+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r101825-zh.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=13011","url":"https:\/\/longmai-nt.com\/?page_id=13011","name":"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=13011#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=13011#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r101825-zh.jpg","datePublished":"2026-09-22T08:01:51+00:00","dateModified":"2026-11-03T05:30:02+00:00","description":"\u6210\u90fd\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff1f\u4e2d\u592e\u8f6f\u6c34\u53bb\u9664\u6c34\u57a2\u9499\u9541\uff0c\u5475\u62a4\u808c\u80a4\u4e0e\u70ed\u6c34\u5668\u3001\u82b1\u6d12\uff1b\u963f\u5c14\u838e\u5a1c\u65e5\u7acb\u6631\u4eab\/\u963f\u6ce2\u7f57\u7cfb\u5217\uff0c1T\/2T\/3T \u6309\u6237\u578b\u9009\uff0c\u514d\u8d39\u4e0a\u95e8\u6d4b\u6c34\u8d28\u51fa\u65b9\u6848\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=13011#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=13011"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=13011#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r101825-zh.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/aesn-zyrsj-est-r101825-zh.jpg","width":2400,"height":1552},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=13011#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u4e2d\u592e\u8f6f\u6c34\u673a\u600e\u4e48\u9009\uff5c\u963f\u5c14\u838e\u5a1c\u4e2d\u592e\u8f6f\u6c34"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13011","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13011"}],"version-history":[{"count":14,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13011\/revisions"}],"predecessor-version":[{"id":17494,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13011\/revisions\/17494"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13011"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}