{"id":13098,"date":"2026-09-23T18:57:46","date_gmt":"2026-09-23T10:57:46","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=13098"},"modified":"2026-11-18T00:04:38","modified_gmt":"2026-11-17T16:04:38","slug":"%e5%85%a8%e5%8f%98%e9%a2%91%e6%b0%b4%e7%b3%bb%e7%bb%9f%e4%b8%a4%e8%81%94%e4%be%9b%e6%8a%80%e6%9c%af%e7%99%bd%e7%9a%ae%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=13098","title":{"rendered":"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66"},"content":{"rendered":"<div class=\"lm-geo\" data-book=\"\u4e24\u8054\u4f9b\" data-cat=\"\u4e24\u8054\u4f9b\" data-layer=\"\u5e72\" data-code=\"\u4e24\u8054\u4f9b\u00b7\u6c34\u5885\u9002\" data-step=\"1\" data-elem=\"\" data-q=\"\u6210\u90fd\u88c5\u4e24\u8054\u4f9b\u6c34\u5885\u9002\uff0c\u600e\u4e48\u624d\u7b97\u88c5\u5bf9\"><\/div>\n<header class=\"hero\">\n<div class=\"inner\">\n    <span class=\"badge\">\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u6280\u672f\u767d\u76ae\u4e66 V3.2<\/span><br \/>\n    \u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<\/p>\n<p>\u4ece\u539f\u7406\u3001\u7cfb\u7edf\u67b6\u6784\u3001\u6750\u6599\u9009\u578b\u3001\u5b89\u88c5\u5de5\u827a\u5230\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u4e0e\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\u2014\u2014\u4e00\u5957\u4e3b\u673a\uff0c\u590f\u5929\u5236\u51b7\u3001\u51ac\u5929\u5730\u6696\u3002<\/p>\n<p>\u65e5\u7acb\u6c34\u5885\u9002\uff08VF\uff09\u94bb\u77f3\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b \u00b7 \u51fa\u8bbe\u8ba1\u56fe\u7eb8\u4e0e\u65b9\u6848\u62a5\u4ef7<\/p>\n<\/p>\n<\/div>\n<\/header>\n<div class=\"wrap\">\n<nav class=\"toc\">\n  <a href=\"#p1\">\u4e00\u3001\u6280\u672f\u6f14\u8fdb\u4e0e\u54c1\u724c\u771f\u76f8<\/a><br \/>\n  <a href=\"#p2\">\u4e8c\u3001\u7cfb\u7edf\u67b6\u6784\u6df1\u5ea6\u89e3\u6790<\/a><br \/>\n  <a href=\"#p3\">\u4e09\u3001\u5e38\u89c1\u6545\u969c\u4e0e\u5e02\u573a\u4e71\u8c61<\/a><br \/>\n  <a href=\"#p4\">\u56db\u3001\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u6307\u5357<\/a><br \/>\n  <a href=\"#p5\">\u4e94\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u672c\u5206\u6790<\/a><br \/>\n  <a href=\"#p6\">\u516d\u3001\u5b9e\u6218\u65b9\u6848\u4e0e\u6c9f\u901a\u8bdd\u672f<\/a><br \/>\n  <a href=\"#p7\">\u4e03\u3001\u522b\u5885\u4e13\u6848\u4e66\uff08\u5b9e\u6218\u6848\u4f8b\uff09<\/a><br \/>\n  <a href=\"#p8\">\u516b\u3001\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/a><br \/>\n  <a href=\"#p9\">\u4e5d\u3001\u63a7\u5236\u7cfb\u7edf\u6df1\u5ea6\u89e3\u6790\u4e0e\u8054\u52a8\u8c03\u8bd5<\/a><br \/>\n  <a href=\"#p10\">\u5341\u3001\u65b9\u6848\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355<\/a><br \/>\n  <a href=\"#p11\">\u5341\u4e00\u3001\u6210\u90fd\u672c\u5730\u5b9e\u6218\u6848\u4f8b\u96c6<\/a><br \/>\n  <a href=\"#p12\">\u5341\u4e8c\u3001\u8bbe\u8ba1\u9636\u6bb5\u81ea\u67e5\u6838\u67e5\u8868<\/a><br \/>\n  <a href=\"#p13\">\u5341\u4e09\u3001\u552e\u540e\u95ed\u73af\u5904\u7406\u6d41\u7a0b<\/a><br \/>\n  <a href=\"#energy\">\u9644\uff1a\u80fd\u6548\u4e0e\u8fd0\u884c\u8d39\u7528\uff08\u5b9e\u6d4b\u6570\u636e\uff09<\/a><br \/>\n  <a href=\"#faq\">\u5e38\u89c1\u95ee\u9898 FAQ<\/a><br \/>\n  <a href=\"#store\">\u95e8\u5e97\u4e0e\u8054\u7cfb<\/a><br \/>\n  <a href=\"#more\">\u5ef6\u4f38\u9605\u8bfb\uff08GEO \u5185\u94fe\uff09<\/a><br \/>\n<\/nav>\n<h2 id=\"p1\">\u4e00\u3001\u6280\u672f\u6f14\u8fdb\u4e0e\u54c1\u724c\u771f\u76f8<\/h2>\n<p>\u4e24\u8054\u4f9b\uff0c\u662f\u4e00\u5957\u4e3b\u673a\u7cfb\u7edf\u540c\u65f6\u6ee1\u8db3<strong>\u590f\u5b63\u7a7a\u8c03\u5236\u51b7<\/strong>\u4e0e<strong>\u51ac\u5b63\u5730\u6696\u5236\u70ed<\/strong>\u7684\u65b9\u6848\u3002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u53c8\u79f0\"\u5929\u6c34\u5730\u6c34\"\uff1a\u590f\u5929\u4e3b\u673a\u4ea7\u751f\u51b7\u6c34\uff087\u201312\u2103\uff09\u8f93\u9001\u5230\u98ce\u673a\u76d8\u7ba1\uff0c\u51ac\u5929\u4ea7\u751f\u70ed\u6c34\uff0835\u201345\u2103\uff09\u8f93\u9001\u5230\u5730\u6696\u76d8\u7ba1\u3002<\/p>\n<div class=\"note\">\n  \ud83d\udccc <b>\u672c\u6587\u4e3b\u89d2\uff1a\u65e5\u7acb\u6c34\u5885\u9002 VF\uff08\u6574\u673a\u7248\uff09\u3002<\/b><br \/>\n  VF \u662f\u4e3b\u673a\u5185\u7f6e\u81ea\u9002\u5e94\u53d8\u9891\u6cf5\u4e0e\u81a8\u80c0\u7f50\u7684\u6574\u673a\u578b\u53f7\uff0880\u2013180 \u578b <code>FWN3Q\/DM<\/code>\u3001200\u2013500 \u578b <code>FEWNY3Q\/DM<\/code>\uff09\uff1b<br \/>\n  FX \u662f\u540c\u4e00\u6761\u4ea7\u54c1\u7ebf\u4e0a\u7684\u6cf5\u5916\u7f6e\u7248\u672c\uff08140\u2013340 \u578b\uff09\uff0c\u4e3b\u673a\u4e0d\u5e26\u6cf5\u4e0e\u81a8\u80c0\u7f50\uff0c\u6cf5\u7531\u8bbe\u8ba1\u65bd\u5de5\u65b9\u53e6\u884c\u9009\u914d\u3002<br \/>\n  \u4e24\u8005\u90fd\u662f<b>\u5929\u6c34\u5730\u6c34<\/b>\u7684\u6c34\u673a\uff0c\u4e0d\u662f\u4e24\u6761\u6362\u70ed\u8def\u7ebf\u2014\u2014\u672c\u6587\u6240\u6709\u7cfb\u7edf\u56fe\u5747\u57fa\u4e8e\u6c34\u5885\u9002 VF \u4e00\u6b21 \/ \u4e8c\u6b21\u7cfb\u7edf\u7ed8\u5236\u3002<br \/>\n  \u6c34\u7cfb\u7edf\u4e0e\"\u5929\u6c1f\u5730\u6c34\"\uff08\u5982 VAM \u5c0a\u777f\u5916\u7f6e\u6c34\u6a21\u5757\u65b9\u6848\uff09\u624d\u662f\u4e0d\u540c\u7684\u6280\u672f\u8def\u7ebf\uff0c<b>\u8bf7\u52ff\u6df7\u6dc6<\/b>\u3002\n<\/div>\n<h3>1.1 \u5168\u53d8\u9891\u624d\u662f\u6838\u5fc3<\/h3>\n<p>\u771f\u6b63\u7684\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff0c\u5fc5\u987b\u540c\u65f6\u5177\u5907\uff1a\u538b\u7f29\u673a\u76f4\u6d41\u53d8\u9891\u3001\u5ba4\u5185\u98ce\u673a\u76f4\u6d41\u65e0\u5237\u7535\u673a\u3001\u6c34\u6cf5\u53d8\u9891\u3002\u50cf\u4e00\u53f0\u667a\u80fd\u7a7a\u8c03\u2014\u2014\u623f\u95f4\u9700\u8981\u591a\u5c11\u51b7\u70ed\u5c31\u8f93\u51fa\u591a\u5c11\u3002<\/p>\n<h3>1.2 \u54c1\u724c\u6280\u672f\u771f\u76f8\uff1a\u7f8e\u7cfb\u54c1\u724c\u7684\"\u65e5\u7cfb\u5185\u6838\"<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u54c1\u724c<\/th>\n<th>\u538b\u7f29\u673a\u6765\u6e90<\/th>\n<th>\u5907\u6ce8<\/th>\n<\/tr>\n<tr>\n<td>\u7ea6\u514b YORK<\/td>\n<td>\u591a\u91c7\u7528\u65e5\u7acb\/\u6d77\u7acb\u538b\u7f29\u673a<\/td>\n<td>\u6bcd\u516c\u53f8\u6c5f\u68ee\u81ea\u63a7\u66fe\u6301\u65e5\u7acb\u7a7a\u8c03 60% \u80a1\u6743<\/td>\n<\/tr>\n<tr>\n<td>\u5f00\u5229 Carrier<\/td>\n<td>\u90e8\u5206\u673a\u578b\u91c7\u7528\u4e09\u83f1\u7535\u673a\u538b\u7f29\u673a<\/td>\n<td>\u5bb6\u7528 MiniVWV \u7cfb\u5217<\/td>\n<\/tr>\n<tr>\n<td>\u7279\u7075 Trane<\/td>\n<td>\u90e8\u5206\u673a\u578b\u91c7\u7528\u4e09\u83f1\u7535\u673a\u538b\u7f29\u673a<\/td>\n<td>\u884c\u4e1a\u8bf4\u6cd5<\/td>\n<\/tr>\n<tr>\n<td>\u65e5\u7acb HITACHI<\/td>\n<td>\u5168\u94fe\u6761\u81ea\u7814\uff08\u538b\u7f29\u673a\u2192\u53d8\u9891\u5668\u2192\u63a7\u5236\u7cfb\u7edf\uff09<\/td>\n<td>\u6c34\u5885\u9002 VF \u5168\u53d8\u9891\u7cfb\u5217<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"note\">\u65e5\u7cfb\u5185\u673a\u5c01\u88c5\u6280\u672f\uff1a\u65e5\u7acb\u7b49\u65e5\u7cfb\u54c1\u724c\u7684\u6c1f\u7cfb\u7edf\u5185\u673a\u4e0e\u6c34\u7cfb\u7edf\u98ce\u76d8\u53ef\u5728\u540c\u4e00\u6761\u751f\u4ea7\u7ebf\u4e0a\u5236\u9020\uff0c\u4ec5\u9700\u66f4\u6362\u6362\u70ed\u5668\u7c7b\u578b\uff0c\u5176\u4f59\u90e8\u4ef6\u5b8c\u5168\u590d\u7528\uff0c\u4f7f\u6c34\u673a\u98ce\u76d8\u65e0\u7f1d\u7ee7\u627f\u6c1f\u673a\u5185\u673a\u7684<strong>\u9759\u97f3\u3001\u8282\u80fd\u3001\u51c0\u5316\u3001\u667a\u80fd\u5316<\/strong>\u6280\u672f\u3002<\/div>\n<h3>1.3 \u65e5\u7acb\u5173\u952e\u65f6\u95f4\u8282\u70b9<\/h3>\n<ul>\n<li>\u7ea6 2015 \u5e74\uff1a\u63a8\u51fa\"\u5f3a\u70ed D\"\u7cfb\u5217\u52a0\u6c34\u6a21\u5757\uff0c\u8fdb\u5165\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u9886\u57df<\/li>\n<li>2023 \u5e74 3 \u6708\uff1a\u53d1\u5e03<strong>\u6c34\u5885\u9002 VF \u5168\u53d8\u9891\u7cfb\u5217<\/strong><\/li>\n<li>2023 \u5e74 6 \u6708\uff1a\u53d1\u5e03\u5168\u5c4b\u5168\u611f 2.0 \u667a\u6167\u7a7a\u6c14\u5b9a\u5236\u7cfb\u7edf<\/li>\n<li>2025 \u5e74 6 \u6708\uff1a\u53d1\u5e03\u5168\u5c4b\u5168\u611f 3.0 \u7cfb\u7edf<\/li>\n<\/ul>\n<h2 id=\"p2\">\u4e8c\u3001\u7cfb\u7edf\u67b6\u6784\u6df1\u5ea6\u89e3\u6790<\/h2>\n<h3>2.1 \u4e00\u6b21\u7cfb\u7edf vs \u4e8c\u6b21\u7cfb\u7edf<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u5bf9\u6bd4\u9879<\/th>\n<th>\u4e00\u6b21\u7cfb\u7edf\uff08\u65e0\u6c34\u7bb1\u00b7\u5168\u53d8\u9891\uff09<\/th>\n<th>\u4e8c\u6b21\u7cfb\u7edf\uff08\u6709\u6c34\u7bb1\u00b7\u53cc\u6cf5\uff09<\/th>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u7ed3\u6784<\/td>\n<td>\u4e3b\u673a\u53d8\u9891\u6cf5\u76f4\u8fde\u672b\u7aef<\/td>\n<td>\u4e3b\u673a\u2192\u6c34\u7bb1\u2192\u4e8c\u6b21\u6cf5\u2192\u672b\u7aef<\/td>\n<\/tr>\n<tr>\n<td>\u53d8\u9891\u5229\u7528\u7387<\/td>\n<td>\u5145\u5206\u53d1\u6325<\/td>\n<td>\u4e3b\u673a\u4fa7\u53d8\u9891\u95f2\u7f6e<\/td>\n<\/tr>\n<tr>\n<td>\u7f13\u51b2\u6c34\u7bb1<\/td>\n<td>\u7cfb\u7edf\u6c34\u91cf\u8fbe\u6807\u65f6\u4e0d\u9700\u8981<\/td>\n<td>\u6807\u914d\uff0c\u4e14\u5e38\u88ab\u6ee5\u7528<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u80fd\u8017<\/td>\n<td>\u6700\u4f4e<\/td>\n<td>\u589e\u52a0\u6c34\u7bb1\u70ed\u635f\u8017 + \u4e8c\u6b21\u6cf5\u529f\u8017<\/td>\n<\/tr>\n<tr>\n<td>\u54cd\u5e94\u901f\u5ea6<\/td>\n<td>\u6700\u5feb<\/td>\n<td>\u8f83\u6162\uff08\u9700\u5148\u52a0\u70ed\/\u51b7\u5374\u6c34\u7bb1\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u9002\u7528\u573a\u666f<\/td>\n<td>\u7edd\u5927\u591a\u6570\u522b\u5885\u3001\u5927\u5e73\u5c42<\/td>\n<td>\u672b\u7aef\u6781\u591a\uff08&gt;15 \u53f0\uff09\u3001\u7ba1\u8def\u6781\u957f\uff08&gt;200m\uff09<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>2.2 \u7f13\u51b2\u6c34\u7bb1\u7684\u771f\u76f8\u4e0e\u8bef\u533a<\/h3>\n<p>\u4e00\u53e5\u8bdd\u6982\u62ec\uff1a<strong>\u7f13\u51b2\u6c34\u7bb1\u53ea\u505a\u4e00\u4ef6\u4e8b\u2014\u2014\u589e\u52a0\u7cfb\u7edf\u91cc\u7684\u603b\u6c34\u91cf\u3002<\/strong><\/p>\n<p>\u5f00\u5229\u5b98\u65b9\u5224\u65ad\u516c\u5f0f\uff1a\u6700\u5c0f\u6c34\u5bb9\u91cf\uff08\u5347\uff09= \u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf\uff08kW\uff09\u00d7 3.25\uff08\u666e\u901a\u8212\u9002\u6027\u7a7a\u8c03\uff09\uff1b\u65e5\u7acb\u6807\u51c6\uff1a\u00d7 2\u3002<\/p>\n<div class=\"card\">\n<h4>\u7f13\u51b2\u6c34\u7bb1\u914d\u7f6e\u89c4\u5219\uff08\u5168\u53d8\u9891\u6c34\u7cfb\u7edf \u00b7 \u9f99\u8109\u7edf\u4e00\u53e3\u5f84\uff09<\/h4>\n<ul class=\"kv\">\n<li><b>\u2460 \u4e00\u6b21\u7cfb\u7edf\uff08\u5168\u53d8\u9891\uff09+ \u603b\u6c34\u91cf \u2265 \u4e3b\u673a\u6807\u51c6\u503c<\/b>\uff08\u5f00\u5229 3.25 L\/kW \u6216 \u65e5\u7acb 2 L\/kW\uff09\u2192 <b>\u514d\u7f13\u51b2\u6c34\u7bb1<\/b>\u3002<\/li>\n<li><b>\u2461 \u4e00\u6b21\u7cfb\u7edf\u4f46\u6c34\u91cf\u4e0d\u8db3<\/b>\uff08\u5c0f\u6237\u578b \/ \u5730\u6696\u9762\u79ef\u5c0f \/ \u7ba1\u7ec6\uff0c\u6c34\u5bb9\u79ef &lt; 2 L\/kW\uff09\u2192 \u6309\u5dee\u503c\u8865\u6c34\u7bb1\uff0c<b>\u4f18\u5148\u589e\u5927\u4e3b\u7ba1\u7ba1\u5f84<\/b>\u800c\u975e\u786c\u52a0\u6c34\u7bb1\u3002<\/li>\n<li><b>\u2462 \u4e8c\u6b21\u7cfb\u7edf<\/b>\uff08\u4e3b\u673a\u2192\u6c34\u7bb1\u2192\u4e8c\u6b21\u6cf5\u2192\u672b\u7aef\uff09\u2192 <b>\u5fc5\u914d<\/b>\u7f13\u51b2\u6c34\u7bb1\uff08\u5e26\u5185\u90e8\u6321\u677f\u3001\u8fdb\u51fa\u6c34\u53e3\u5206\u5c45\u4e24\u4fa7\uff09\u3002<\/li>\n<li><b>\u2463 \u5b9a\u9891 \/ \u58c1\u6302\u7089\u7cfb\u7edf<\/b> \u2192 <b>\u5fc5\u914d<\/b>\uff08\u903b\u8f91\u540c\u4e8c\u6b21\u7cfb\u7edf\uff0c\u5b88\u4f4f\u5b89\u5168\u5e95\u7ebf\uff09\u3002<\/li>\n<\/ul>\n<\/div>\n<div class=\"warn\">\u26a0\ufe0f \u65e9\u671f\"\u51e1\u662f\u6c34\u673a\u90fd\u8981\u52a0\u6c34\u7bb1\"\u662f\u5b9a\u9891\u65f6\u4ee3\u7684\u60ef\u6027\u3002\u5730\u6696\u56de\u586b\u5c42\u81ea\u8eab\u5c31\u662f\u8d85\u5927\u84c4\u70ed\u6c34\u4f53\u2014\u2014100\u33a1 \u5730\u6696\u56de\u586b\u5c42\u7b49\u6548\u6c34\u91cf\u7ea6 2,100 \u5347\uff0c\u662f\u5e38\u89c4\u7f13\u51b2\u6c34\u7bb1\uff0860\u2013150L\uff09\u7684 14\u201335 \u500d\u3002\u6c34\u7bb1\u8fc7\u5927\u53cd\u800c\u589e\u52a0\u70ed\u60ef\u6027\u3001\u62d6\u6162\u54cd\u5e94\u3001\u591a\u8017\u7535\u3002<\/div>\n<h3>2.3 \u5168\u53d8\u9891\u7cfb\u7edf\u7684\u6838\u5fc3\u4f18\u52bf<\/h3>\n<p>\u2705 \u53d8\u9891\u538b\u7f29\u673a\uff08\u6309\u9700\u8f93\u51fa\u51b7\u70ed\u91cf\uff09\u3000\u2705 \u5185\u7f6e\u53d8\u9891\u6c34\u6cf5\uff08\u6309\u9700\u8c03\u8282\u6c34\u6d41\u91cf\uff09\u3000\u2705 \u5c01\u88c5\u5f0f\u5bb6\u7528\u5185\u673a\uff08\u98ce\u76d8\uff09\u3000\u2705 \u8054\u52a8\u63a7\u5236\u903b\u8f91\u3002\u8fd0\u884c\u7a33\u5b9a\u3001\u6545\u969c\u7387\u4f4e\u3001\u5bff\u547d\u957f\u3001\u4e0d\u9700\u8981\u989d\u5916\u52a0\u88c5\u6c34\u6cf5\u6c34\u7bb1\u3001\u4e0d\u4f1a\u51fa\u73b0\"\u5355\u5f00\u62a5\u8b66\"\u3002<\/p>\n<h3>2.4 \u538b\u5dee\u65c1\u901a\u9600\u7684\u5e94\u7528\u573a\u666f<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u7cfb\u7edf\u5f62\u5f0f<\/th>\n<th>\u662f\u5426\u9700\u8981\u538b\u5dee\u65c1\u901a\u9600<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<tr>\n<td>\u4e00\u6b21\u7cfb\u7edf + \u5168\u53d8\u9891\u6cf5<\/td>\n<td>\u274c \u4e00\u822c\u4e0d\u9700\u8981<\/td>\n<td>\u53d8\u9891\u6cf5\u81ea\u52a8\u5339\u914d\u672b\u7aef\u6d41\u91cf\u53d8\u5316<\/td>\n<\/tr>\n<tr>\n<td>\u4e00\u6b21\u7cfb\u7edf + \u5b9a\u9891\u6cf5<\/td>\n<td>\u2705 \u5fc5\u987b\u5b89\u88c5<\/td>\n<td>\u672b\u7aef\u5173\u95ed\u65f6\u538b\u5dee\u5347\u9ad8\uff0c\u4ea7\u751f\u566a\u97f3\u548c\u9707\u52a8<\/td>\n<\/tr>\n<tr>\n<td>\u4e8c\u6b21\u7cfb\u7edf + \u4e8c\u6b21\u4fa7\u5b9a\u9891\u6cf5<\/td>\n<td>\u2705 \u5fc5\u987b\u5b89\u88c5<\/td>\n<td>\u5b89\u88c5\u4e8e\u672b\u7aef\u603b\u7ba1\u5904<\/td>\n<\/tr>\n<tr>\n<td>\u4e8c\u6b21\u7cfb\u7edf + \u4e8c\u6b21\u4fa7\u53d8\u9891\u6cf5<\/td>\n<td>\u26a0\ufe0f \u89c6\u60c5\u51b5<\/td>\n<td>\u770b\u6c34\u6cf5\u53d8\u9891\u4e0b\u9650\u4e0e\u5b9e\u9645\u9700\u6c42\u662f\u5426\u5339\u914d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg\" alt=\"\u6c34\u5885\u9002VF\u5355\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe\"><\/p>\n<div class=\"fig\">\u6c34\u5885\u9002 VF \u5355\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u65e0\u6c34\u7bb1\u00b7\u5168\u53d8\u9891\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxsjblxtylt.jpg\" alt=\"\u6c34\u5885\u9002VF\u53cc\u673a\u5e76\u8054\u7cfb\u7edf\u539f\u7406\u56fe\"><\/p>\n<div class=\"fig\">\u6c34\u5885\u9002 VF \u53cc\u673a\u5e76\u8054\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u5927\u6237\u578b \/ \u522b\u5885\u591a\u673a\u6269\u5bb9\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxt-dhcsx-ylt.jpg\" alt=\"\u6c34\u5885\u9002VF\u4e00\u6b21\u7cfb\u7edf\u5e26\u7f13\u51b2\u6c34\u7bb1\u539f\u7406\u56fe\"><\/p>\n<div class=\"fig\">\u6c34\u5885\u9002 VF \u4e00\u6b21\u7cfb\u7edf\u00b7\u5e26\u7f13\u51b2\u6c34\u7bb1\uff08\u4e8c\u6b21 \/ \u6c34\u91cf\u4e0d\u8db3\u65f6\u91c7\u7528\uff0c\u89c1 2.2\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxecxt-ldjxsyt.jpg\" alt=\"\u6c34\u5885\u9002VF\u4e8c\u6b21\u7cfb\u7edf\u8054\u52a8\u63a5\u7ebf\u56fe\"><\/p>\n<div class=\"fig\">\u6c34\u5885\u9002 VF \u4e8c\u6b21\u7cfb\u7edf\u00b7\u8054\u52a8\u63a5\u7ebf\uff08\u672b\u7aef&gt;15 \u53f0 \/ \u7ba1\u8def&gt;200m\uff09<\/div>\n<\/p>\n<\/div>\n<\/div>\n<p class=\"kv\" style=\"text-align:center\">\u25b2 \u6c34\u5885\u9002 VF\uff08\u6574\u673a\u7248\uff0c\u5185\u7f6e\u53d8\u9891\u6cf5\uff09\u4e0e FX\uff08\u6cf5\u5916\u7f6e\u7248\uff09\u540c\u5c5e\u65e5\u7acb\u6237\u5f0f\u5168\u53d8\u9891\u6c34\u673a\u4ea7\u54c1\u7ebf\uff0c\u5dee\u522b\u5728\u6cf5\u7684\u4f4d\u7f6e\u4e0e\u8986\u76d6\u6bb5\uff0c\u4e0d\u5728\u6362\u70ed\u8def\u7ebf\u3002\u672c\u6587\u7cfb\u7edf\u56fe\u57fa\u4e8e VF \u6574\u673a\u7248\u7ed8\u5236\u3002<\/p>\n<h2 id=\"p3\">\u4e09\u3001\u5e38\u89c1\u6545\u969c\u4e0e\u5e02\u573a\u4e71\u8c61<\/h2>\n<h3>3.1 \u4e09\u7c7b\u5178\u578b\u6545\u969c<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u6545\u969c\u73b0\u8c61<\/th>\n<th>\u539f\u56e0\u5206\u6790<\/th>\n<th>\u6392\u9664\u65b9\u6cd5<\/th>\n<\/tr>\n<tr>\n<td>\u6392\u6c14\u538b\u529b\u8fc7\u9ad8<\/td>\n<td>\u51b7\u51dd\u5668\u8fdb\u6c34\u6e29\u5ea6\u8fc7\u9ad8 \/ \u6d41\u91cf\u4e0d\u8db3<\/td>\n<td>\u68c0\u67e5\u6c34\u8fc7\u6ee4\u5668\u3001\u6392\u7a7a\u6c14<\/td>\n<\/tr>\n<tr>\n<td>\u6362\u70ed\u5668\u51bb\u88c2<\/td>\n<td>\u6d41\u901f\u8fc7\u6162\u5236\u51b7\u7ed3\u51b0\uff1b\u6d41\u91cf\u5f00\u5173\u88ab\u77ed\u63a5<\/td>\n<td>\u786e\u4fdd\u6700\u5c0f\u6c34\u6d41\u91cf\uff1b\u4e25\u7981\u53d6\u6d88\u6d41\u91cf\u4fdd\u62a4<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6d41\u6545\u969c\u62a5\u8b66<\/td>\n<td>\u6d41\u91cf\u8fc7\u5927\u6216\u8fc7\u5c0f\uff1b\u6c34\u6cf5\u9009\u578b\u4e0d\u5f53<\/td>\n<td>\u68c0\u67e5\u6c34\u6cf5\u5339\u914d\uff1b\u6e05\u6d17\u8fc7\u6ee4\u5668<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3.2 \u5f53\u524d\u5e02\u573a\u56db\u5927\u4e71\u8c61<\/h3>\n<ul>\n<li><b>\u4e71\u8c61\u4e00\uff1a\u65b9\u6848\u5012\u9000<\/b>\u2014\u2014\u628a\"\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\"\u5f3a\u884c\u8bbe\u8ba1\u4e3a\"\u4e8c\u6b21\u7cfb\u7edf + \u7f13\u51b2\u6c34\u7bb1\"\u3002<\/li>\n<li><b>\u4e71\u8c61\u4e8c\uff1a\u786c\u4ef6\u51cf\u914d<\/b>\u2014\u2014\u628a\u5168\u5305\u5f0f\u98ce\u76d8\u5077\u6362\u6210\u534a\u5305\u5f0f\u98ce\u76d8\uff0c\u5355\u53f0\u5dee\u4ef7 2000 \u5143\u4ee5\u4e0a\u3002<\/li>\n<li><b>\u4e71\u8c61\u4e09\uff1a\u63a7\u5236\u7f3a\u5931<\/b>\u2014\u2014\u4e0d\u505a\u6c34\u6cf5\u8054\u52a8\uff0c\u6c34\u6cf5 24 \u5c0f\u65f6\u8fd0\u8f6c\u3002<\/li>\n<li><b>\u4e71\u8c61\u56db\uff1a\u8425\u9500\u8bef\u5bfc<\/b>\u2014\u2014\u6253\u7740\"\u7f8e\u7cfb\u4e13\u4e1a\u6c34\u673a\"\u65d7\u53f7\uff0c\u63a9\u76d6\u65e5\u7cfb\u6280\u672f\u5185\u6838\u3002<\/li>\n<\/ul>\n<div class=\"note\">\u4e3a\u4ec0\u4e48\u5546\u5bb6\u7231\u63a8\"\u52a0\u6c34\u7bb1\u3001\u4e8c\u6b21\u7cfb\u7edf\"\uff1f\u2460 \u63a9\u76d6\u4e0d\u4f1a\u7b97\u7ba1\u5f84\u7684\u8bbe\u8ba1\u7f3a\u9677\uff1b\u2461 \u591a\u5356\u8bbe\u5907\u591a\u8d5a\u94b1\uff08\u7f13\u51b2\u6c34\u7bb1 + \u4e8c\u6b21\u6cf5 + \u8f85\u6750 \u2248 \u591a\u6536 6000\u20138000 \u5143\uff09\uff1b\u2462 \u7f51\u7ea2\u3001\u535a\u4e3b\u4e0d\u61c2\u539f\u7406\u8ddf\u98ce\u4f20\u64ad\u3002<\/div>\n<h2 id=\"p4\">\u56db\u3001\u6838\u5fc3\u6750\u6599\u4e0e\u9009\u578b\u6307\u5357<\/h2>\n<h3>4.1 \u7ba1\u9053\u4e0e\u7ba1\u6750<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u7cfb\u7edf\u90e8\u4f4d<\/th>\n<th>\u63a8\u8350\u7ba1\u6750<\/th>\n<th>\u63a8\u8350\u89c4\u683c<\/th>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u76d8\u7ba1<\/td>\n<td>PERT<\/td>\n<td>De20<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u4e3b\u7ba1<\/td>\n<td>\u4f1f\u661f F-PPRCT\uff08\u9996\u9009\uff09\/ PPR\uff08S3.2\uff09<\/td>\n<td>\u6309\u6c34\u529b\u8ba1\u7b97<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u652f\u7ba1<\/td>\n<td>\u94dd\u5851\u590d\u5408\u7ba1<\/td>\n<td>De20\u2013De25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>4.2 \u7ba1\u5f84\u2013\u6d41\u91cf\u2013\u70ed\u503c\u901f\u67e5\u8868\uff0810\u2103 \u6e29\u5dee\uff09<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u7ba1\u5f84<\/th>\n<th>\u53c2\u8003\u6d41\u91cf<\/th>\n<th>\u53ef\u643a\u5e26\u70ed\u503c<\/th>\n<th>\u7ea6\u675f\u6761\u4ef6<\/th>\n<\/tr>\n<tr>\n<td>De16<\/td>\n<td>~100 L\/h<\/td>\n<td>~1.2 kW<\/td>\n<td>\u76d8\u7ba1\u2264120m\uff0c\u6d41\u901f\u22640.5m\/s<\/td>\n<\/tr>\n<tr>\n<td>De20<\/td>\n<td>~200 L\/h<\/td>\n<td>~2.3 kW<\/td>\n<td>\u76d8\u7ba1\u2264120m\uff0c\u6d41\u901f\u22640.5m\/s<\/td>\n<\/tr>\n<tr>\n<td>De25<\/td>\n<td>~500 L\/h<\/td>\n<td>~5.8 kW<\/td>\n<td>\u652f\u7ba1\u226450m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td>De32<\/td>\n<td>~1,000 L\/h<\/td>\n<td>~11.6 kW<\/td>\n<td>\u4e3b\u7ba1\u226480m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<tr>\n<td>De40<\/td>\n<td>~2,000 L\/h<\/td>\n<td>~23.2 kW<\/td>\n<td>\u4e3b\u7ba1\u2264100m\uff0c\u6d41\u901f\u22641.0m\/s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"warn\">\u26a0\ufe0f PPR \u7ba1\u7cfb\u5217\uff1aS \u503c\u8d8a\u5c0f\u58c1\u8d8a\u539a\u3002\u7a7a\u8c03\u4e3b\u7ba1\u4e25\u7981 S5\uff0cS4 \u9700\u6821\u6838\u6d41\u91cf\uff0c<b>S3.2 \u4e3a\u4e24\u8054\u4f9b\u4e3b\u7ba1\u9053\u9996\u9009<\/b>\u3002\u963b\u6c27\u7ba1\u539f\u5219\uff1a\u4e00\u534a\u963b\u6c27\u4e00\u534a\u4e0d\u963b\u6c27 = \u767d\u505a\u3002<\/div>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-ac-plan-01.jpg\" alt=\"\u6696\u901a\u8bbe\u8ba1\u56fe-\u4e2d\u592e\u7a7a\u8c03\u5e73\u9762\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u4e2d\u592e\u7a7a\u8c03\uff08\u542b\u4e24\u8054\u4f9b\uff09\u5e73\u9762\u5e03\u7f6e\u56fe\u793a\u4f8b<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg\" alt=\"\u901a\u7528\u8bbe\u8ba1\u56fe-\u6c34\u673a\u7a7a\u8c03\u65bd\u5de5\u5e73\u9762\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u6c34\u673a\u7a7a\u8c03\u65bd\u5de5\u5e73\u9762\u56fe\uff08\u7ba1\u5f84 \/ \u8def\u7531\u6807\u6ce8\uff09<\/div>\n<\/p>\n<\/div>\n<\/div>\n<h2 id=\"p5\">\u4e94\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u672c\u5206\u6790<\/h2>\n<h3>5.1 \u6c34\u673a vs \u6c1f\u673a\u5b89\u88c5\u5dee\u5f02<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u5bf9\u6bd4\u9879<\/th>\n<th>\u6c1f\u673a<\/th>\n<th>\u6c34\u673a<\/th>\n<\/tr>\n<tr>\n<td>\u6807\u51c6\u5316\u7a0b\u5ea6<\/td>\n<td>\u9ad8<\/td>\n<td>\u4f4e<\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u6548\u7387<\/td>\n<td>\u9ad8\uff0810+ \u53f0\/\u5929\uff09<\/td>\n<td>\u4f4e\uff08\u7ea6 2 \u53f0\/\u5929\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5bf9\u5de5\u827a\u8981\u6c42<\/td>\n<td>\u4e2d\u7b49<\/td>\n<td>\u6781\u9ad8<\/td>\n<\/tr>\n<tr>\n<td>\u4eba\u5de5\u6210\u672c<\/td>\n<td>\u7ea6 600 \u5143\/\u53f0<\/td>\n<td>800\u20131200 \u5143\/\u53f0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>5.2 \u91d1\u5c5e\u63a5\u5934\u4e09\u9053\u5bc6\u5c01\u5de5\u827a<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u5de5\u5e8f<\/th>\n<th>\u6750\u6599<\/th>\n<th>\u4f5c\u7528<\/th>\n<\/tr>\n<tr>\n<td>\u7b2c\u4e00\u9053<\/td>\n<td>\u4f18\u8d28\u751f\u6599\u5e26<\/td>\n<td>\u586b\u5145\u87ba\u7eb9\u95f4\u9699<\/td>\n<\/tr>\n<tr>\n<td>\u7b2c\u4e8c\u9053<\/td>\n<td>\u4e13\u7528\u538c\u6c27\u5bc6\u5c01\u80f6<\/td>\n<td>\u589e\u52a0\u7c98\u63a5\u5f3a\u5ea6\u548c\u8010\u5019\u6027<\/td>\n<\/tr>\n<tr>\n<td>\u7b2c\u4e09\u9053<\/td>\n<td>\u9ebb\u4e1d<\/td>\n<td>\u589e\u5f3a\u6297\u9707\u52a8\u548c\u51b7\u70ed\u51b2\u51fb<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u7981\u6b62\uff1a\u4ec5\u7528\u6db2\u4f53\u751f\u6599\u5e26\uff08\u70ed\u80c0\u51b7\u7f29\u6613\u788e\u88c2\uff0c\u788e\u6e23\u5835\u585e\u6362\u70ed\u5668\uff09\u3002<\/p>\n<h3>5.3 \u6c34\u673a\u5b89\u88c5\u4e09\u91cd\u4fdd\u538b\u5236\u5ea6<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u4fdd\u538b\u9636\u6bb5<\/th>\n<th>\u538b\u529b\u6807\u51c6<\/th>\n<th>\u4fdd\u538b\u65f6\u957f<\/th>\n<th>\u8d23\u4efb\u4eba<\/th>\n<\/tr>\n<tr>\n<td>\u7ba1\u9053\u5b89\u88c5\u5b8c\u6210<\/td>\n<td>\u5de5\u4f5c\u538b\u529b 1.5 \u500d\u4e14 \u22650.6MPa<\/td>\n<td>24 \u5c0f\u65f6\uff08\u538b\u964d\u22640.02MPa\uff09<\/td>\n<td>\u5b89\u88c5\u73ed\u7ec4<\/td>\n<\/tr>\n<tr>\n<td>\u9690\u853d\u5de5\u7a0b\u524d<\/td>\n<td>\u540c\u7b2c\u4e00\u9636\u6bb5\u6807\u51c6<\/td>\n<td>\u518d\u6b21\u786e\u8ba4\u540e\u9690\u853d<\/td>\n<td>\u8d28\u68c0\u5458<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u8c03\u8bd5\u524d<\/td>\n<td>\u7cfb\u7edf\u8bbe\u8ba1\u538b\u529b<\/td>\n<td>\u6301\u7eed\u4fdd\u538b\u81f3\u8c03\u8bd5<\/td>\n<td>\u8c03\u8bd5\u5de5\u7a0b\u5e08<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p02-11.jpeg\" alt=\"\u98ce\u673a\u76d8\u7ba1\u51fa\u98ce\u53e3-\u6c34\u7cfb\u7edf\u672b\u7aef\u7f8e\u5b66\u98ce\u53e3\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u98ce\u673a\u76d8\u7ba1\u51fa\u98ce\u53e3\uff08\u6c34\u7cfb\u7edf\u672b\u7aef\u00b7\u7f8e\u5b66\u98ce\u53e3\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lqhdlz-lls-jfsqaz-cpbhhby-01.jpg\" alt=\"\u96c6\u5206\u6c34\u5668\u5b89\u88c5-\u6210\u54c1\u4fdd\u62a4\u4e0e\u4fdd\u538b\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u96c6\u5206\u6c34\u5668\u5b89\u88c5\u00b7\u6210\u54c1\u4fdd\u62a4\u4e0e\u4fdd\u538b<\/div>\n<\/p>\n<\/div>\n<\/div>\n<h2 id=\"p6\">\u516d\u3001\u5b9e\u6218\u65b9\u6848\u4e0e\u6c9f\u901a\u8bdd\u672f<\/h2>\n<h3>6.1 \u9500\u552e\u5bf9\u5ba2\u6237\u8bf4\u7684\u5927\u767d\u8bdd<\/h3>\n<ul>\n<li><b>\u6c34\u673a\u5230\u5e95\u662f\u4ec0\u4e48\uff1f<\/b> \u4e00\u5957\u53d8\u9891\u6c1f\u673a\u7cfb\u7edf\u4e2d\u95f4\u52a0\u4e86\u4e2a\u6c1f\u6c34\u6362\u70ed\u5668\u3002\u590f\u5929\u51b7\u6c34\u8fdb\u98ce\u673a\u76d8\u7ba1\uff0c\u51ac\u5929\u70ed\u6c34\u8fdb\u5730\u6696\u7ba1\u3002<\/li>\n<li><b>\u53d8\u9891\u548c\u5b9a\u9891\u5dee\u5728\u54ea\uff1f<\/b> \u53d8\u9891 5 \u5339\u673a\u542f\u52a8\u53ea\u9700 1\u20132kW\uff0c\u50cf\u6162\u6162\u8e29\u6cb9\u95e8\uff1b\u5b9a\u9891 24kW \u9505\u7089\u542f\u52a8\u5373\u6ee1\u8d1f\u8377\uff0c\u50cf\u6cb9\u95e8\u8e29\u5230\u5e95\u3002<\/li>\n<li><b>\u7f13\u51b2\u6c34\u7bb1\u6709\u6ca1\u6709\u5fc5\u8981\uff1f<\/b> \u5b9a\u9891\u7cfb\u7edf\u786e\u5b9e\u9700\u8981\uff1b\u5168\u53d8\u9891\u7cfb\u7edf\u5b8c\u5168\u4e0d\u9700\u8981\uff0c\u53d8\u9891\u6c34\u6cf5\u81ea\u52a8\u5339\u914d\u6d41\u91cf\u3002<\/li>\n<\/ul>\n<h3>6.2 \u6838\u5fc3\u8bdd\u672f\u5e93<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u5ba2\u6237\u63d0\u95ee<\/th>\n<th>\u56de\u5e94\u8981\u70b9<\/th>\n<\/tr>\n<tr>\n<td>\"\u6c34\u673a\u662f\u4e0d\u662f\u66f4\u8d39\u7535\uff1f\"<\/td>\n<td>\u5168\u53d8\u9891\u6c34\u673a IPLV \u6781\u9ad8\uff0c\u5730\u6696\u5b63\u8282\u6bd4\u71c3\u6c14\u7701 40% \u4ee5\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>\"\u6c34\u7ba1\u4f1a\u4e0d\u4f1a\u6f0f\u6c34\uff1f\"<\/td>\n<td>\u627f\u8ba4\u98ce\u9669\uff0c\u5f3a\u8c03\u4e09\u9053\u5bc6\u5c01 + \u4e09\u91cd\u4fdd\u538b + \u54c1\u724c\u7ba1\u9053<\/td>\n<\/tr>\n<tr>\n<td>\"\u4e3a\u4ec0\u4e48\u8981\u9009\u4e00\u6b21\u7cfb\u7edf\uff1f\"<\/td>\n<td>\u5168\u53d8\u9891\u662f\u539f\u5382\u6cb9\u7bb1\uff0c\u52a0\u6c34\u7bb1\u662f\u52a0\u526f\u6cb9\u7bb1<\/td>\n<\/tr>\n<tr>\n<td>\"\u5c0f\u9a6c\u62c9\u5927\u8f66\u600e\u4e48\u5904\u7406\uff1f\"<\/td>\n<td>\u6c34\u673a\u662f<strong>\u6c34\u7cfb\u7edf<\/strong>\uff0c\u4e0d\u5b58\u5728\u6c1f\u673a\"\u62c9\u62a5\u5e9f\"\u98ce\u9669\uff1b\u538b\u7f29\u673a\u4e0d\u76f4\u63a5\u9762\u5bf9\u672b\u7aef\uff0c<strong>\u6c34\u6cf5\u51b3\u5b9a\u6d41\u91cf<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>6.3 \u5c0f\u9a6c\u62c9\u5927\u8f66\u7684\u5b8c\u6574\u5e94\u5bf9\u6307\u5357<\/h3>\n<h4>6.3.1 \u95ee\u9898\u6839\u6e90\u5206\u6790<\/h4>\n<ul>\n<li><b>\u6280\u672f\u6839\u6e90\uff1a<\/b>\u6df7\u6dc6\u6c1f\u673a\u548c\u6c34\u673a\u7684\u914d\u7f6e\u903b\u8f91\u3002<strong>\u6c1f\u673a\u662f\"\u4e00\u6b21\u7cfb\u7edf\"\uff08\u51b7\u5a92\u76f4\u8fde\u672b\u7aef\uff09\uff1b\u6c34\u673a\u4ee5\u6c34\u4e3a\u4ecb\u8d28\u4f20\u9012\uff0c\u914d\u7f6e\u903b\u8f91\u662f\"\u6c34\u6cf5\u51b3\u5b9a\u6d41\u91cf\"\uff0c\u5e76\u975e\"\u4e8c\u6b21\u7cfb\u7edf\"<\/strong>\u3002\u4e24\u79cd\u7cfb\u7edf\u7684\u7269\u7406\u7ea6\u675f\u5b8c\u5168\u4e0d\u540c\u3002<\/li>\n<li><b>\u5fc3\u7406\u6839\u6e90\uff1a<\/b>\u628a\u6c1f\u673a\"\u5168\u5f00\u8d85\u8d1f\u8377\u635f\u574f\"\u7684\u98ce\u9669\u9519\u8bef\u8fc1\u79fb\u5230\u6c34\u673a\u4e0a\u3002<\/li>\n<li><b>\u5e02\u573a\u6839\u6e90\uff1a<\/b>\u90e8\u5206\u4e0d\u826f\u5546\u5bb6\u5229\u7528\u5ba2\u6237\u6050\u60e7\u63a8\u9500\u66f4\u5927\u7684\u4e3b\u673a\u3002<\/li>\n<\/ul>\n<h4>6.3.2 \u539f\u7406\u8bb2\u89e3<\/h4>\n<p><b>\u6c1f\u673a\u4e3a\u4ec0\u4e48\"\u5fc5\u987b\u914d\u5927\"\uff1f<\/b> \u4e00\u6b21\u7cfb\u7edf\uff1a\u51b7\u5a92\u76f4\u63a5\u4ece\u538b\u7f29\u673a\u5206\u914d\u5230\u5404\u5185\u673a\uff1b\u8fde\u63a5\u7387\u9650\u5236\uff1a\u5185\u673a\u603b\u529f\u7387 \u00f7 1.3 = \u5916\u673a\u6700\u5c0f\u529f\u7387\u3002170\u33a1 \u793a\u4f8b\uff1a\u5185\u673a\u603b\u529f\u7387 \u2248 34kW \u2192 \u5916\u673a \u2265 26kW\u3002\u5168\u5f00\u65f6\u5c0f\u4e3b\u673a\u76f4\u63a5\u62a5\u6545\u969c\u751a\u81f3\u635f\u574f\u3002<\/p>\n<p><b>\u6c34\u673a\u4e3a\u4ec0\u4e48\"\u53ef\u4ee5\u914d\u5c0f\"\uff1f<\/b> \u6c34\u7cfb\u7edf\u7ed3\u6784\uff1a\u538b\u7f29\u673a\u4e0d\u76f4\u63a5\u9762\u5bf9\u672b\u7aef\uff0c<strong>\u6c34\u6cf5\u51b3\u5b9a\u6d41\u91cf<\/strong>\u3002\u53ef\u6309\u5b9e\u9645\u4f7f\u7528\u9700\u6c42\u914d\u7f6e\uff0c\u4e0d\u62c5\u5fc3\"\u62c9\u62a5\u5e9f\"\u3002170\u33a1 \u793a\u4f8b\uff1a\u5e38\u5f00 3 \u53f0\uff085\u20138kW\uff09\uff0c\u914d\u5c0f\u4e3b\u673a\u5c31\u591f\u4e86\u3002<\/p>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-floor-heating-zones-02.jpg\" alt=\"\u6696\u901a\u8bbe\u8ba1\u56fe-\u5730\u6696\u5e73\u9762\u5206\u533a\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u5730\u6696\u5e73\u9762\u5206\u533a\u56fe\uff08\u5206\u5ba4\u63a7\u6e29\u57fa\u7840\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg\" alt=\"\u667a\u4eab\u53cc\u63a7\u578b\u4e24\u8054\u4f9b\u7cfb\u7edf\u539f\u7406\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u667a\u4eab\u53cc\u63a7\u578b\u4e24\u8054\u4f9b\u7cfb\u7edf\u539f\u7406\u56fe<\/div>\n<\/p>\n<\/div>\n<\/div>\n<h2 id=\"p7\">\u4e03\u3001\u522b\u5885\u4e13\u6848\u4e66\uff08\u5b9e\u6218\u6848\u4f8b\uff09<\/h2>\n<h3>7.1 \u9879\u76ee\u80cc\u666f<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u4fe1\u606f<\/th>\n<\/tr>\n<tr>\n<td>\u5ba2\u6237<\/td>\n<td>\u5f20\u5148\u751f<\/td>\n<\/tr>\n<tr>\n<td>\u5efa\u7b51\u9762\u79ef<\/td>\n<td>400\u33a1\uff08\u7a7a\u8c03\u9762\u79ef\u7ea6 283\u33a1\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u80fd\u529b<\/td>\n<td>28kW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>7.2 \u7f13\u51b2\u6c34\u7bb1\u7684\u771f\u76f8\u2014\u2014\u7cbe\u786e\u6c34\u91cf\u8ba1\u7b97<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u7ec4\u6210\u90e8\u5206<\/th>\n<th>\u6c34\u91cf\uff08L\uff09<\/th>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u5185\u7f6e\u6c34\u6a21\u5757<\/td>\n<td>\u7ea6 20<\/td>\n<\/tr>\n<tr>\n<td>9 \u53f0\u98ce\u673a\u76d8\u7ba1<\/td>\n<td>\u7ea6 25<\/td>\n<\/tr>\n<tr>\n<td>50mm \u4e3b\u7ba1\uff08\u7ea6 80 \u7c73\uff09<\/td>\n<td>\u7ea6 157<\/td>\n<\/tr>\n<tr>\n<td>\u652f\u7ba1\uff08\u7ea6 50 \u7c73\uff09<\/td>\n<td>\u7ea6 25<\/td>\n<\/tr>\n<tr>\n<td><b>\u7cfb\u7edf\u603b\u6c34\u91cf<\/b><\/td>\n<td><b>\u7ea6 227L<\/b><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u5f00\u5229\u6807\u51c6\u6700\u4f4e\u6c34\u91cf\uff1a28 \u00d7 3.25 = 91L\uff1b\u65e5\u7acb\u6807\u51c6\uff1a28 \u00d7 2 = 56L\u3002<strong>\u7cfb\u7edf\u6c34\u91cf\u8fdc\u8d85\u4e24\u79cd\u6807\u51c6\uff0c\u5b8c\u5168\u4e0d\u9700\u8981\u7f13\u51b2\u6c34\u7bb1\u3002<\/strong><\/p>\n<h3>7.3 \u4e09\u79cd\u65b9\u6848 20 \u5e74\u603b\u6295\u5165\u5bf9\u6bd4<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u6295\u5165\u9879<\/th>\n<th>\u65b9\u6848A\uff08\u4e00\u6b21\u65e0\u6c34\u7bb1\uff09<\/th>\n<th>\u65b9\u6848B\uff08\u4e00\u6b21\u6709\u6c34\u7bb1\uff09<\/th>\n<th>\u65b9\u6848C\uff08\u4e8c\u6b21\u7cfb\u7edf\uff09<\/th>\n<\/tr>\n<tr>\n<td>\u521d\u6295\u8d44<\/td>\n<td>\u57fa\u51c6<\/td>\n<td>+3,000 \u5143<\/td>\n<td>+6,500 \u5143<\/td>\n<\/tr>\n<tr>\n<td>20 \u5e74\u7535\u8d39<\/td>\n<td>42,520 \u5143<\/td>\n<td>44,900 \u5143<\/td>\n<td>48,140 \u5143<\/td>\n<\/tr>\n<tr>\n<td>20 \u5e74\u7ef4\u62a4\u6210\u672c<\/td>\n<td>\u57fa\u51c6<\/td>\n<td>+1,000 \u5143<\/td>\n<td>+4,000 \u5143<\/td>\n<\/tr>\n<tr>\n<td><b>20 \u5e74\u603b\u6295\u5165<\/b><\/td>\n<td><b>\u57fa\u51c6\uff08\u6700\u4f18\uff09<\/b><\/td>\n<td><b>+6,380 \u5143<\/b><\/td>\n<td><b>+16,120 \u5143<\/b><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-floor-heating-installation-03.jpg\" alt=\"\u6696\u901a\u8bbe\u8ba1\u56fe-\u5730\u6696\u5e73\u9762\u5b89\u88c5\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u5730\u6696\u5e73\u9762\u5b89\u88c5\u56fe\uff08\u522b\u5885\u4e13\u6848\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-floor-heating-wiring-04.jpg\" alt=\"\u6696\u901a\u8bbe\u8ba1\u56fe-\u5730\u6696\u8054\u52a8\u7ebf\u8def\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u5730\u6696\u8054\u52a8\u7ebf\u8def\u56fe\uff08\u5ba4\u6e29\u2192\u6c34\u6cf5\u2192\u4e3b\u673a\uff09<\/div>\n<\/p>\n<\/div>\n<\/div>\n<h2 id=\"p8\">\u516b\u3001\u552e\u540e\u5e38\u89c1\u95ee\u9898\u4e0e\u7cfb\u7edf\u7ef4\u4fdd<\/h2>\n<h3>8.1 \u6c34\u7cfb\u7edf\u5e38\u89c1\u552e\u540e\u95ee\u9898<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u95ee\u9898\u73b0\u8c61<\/th>\n<th>\u53ef\u80fd\u539f\u56e0<\/th>\n<th>\u6392\u67e5\u65b9\u5411<\/th>\n<\/tr>\n<tr>\n<td>\u62a5\u6c34\u6d41\u6545\u969c\uff087A\uff09<\/td>\n<td>\u6c34\u538b\u8fc7\u4f4e\u3001\u8fc7\u6ee4\u5668\u5835\u585e\u3001\u6c34\u6cf5\u5f02\u5e38<\/td>\n<td>\u68c0\u67e5\u538b\u529b\u3001\u6e05\u6d17\u8fc7\u6ee4\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u4e3b\u673a\u9891\u7e41\u542f\u505c<\/td>\n<td>\u6c34\u91cf\u4e0d\u8db3 \/ \u6c34\u7bb1\u914d\u7f6e\u4e0d\u5f53<\/td>\n<td>\u6309\u6807\u51c6\u914d\u7f6e\u6c34\u7bb1\u6216\u589e\u5927\u7ba1\u5f84<\/td>\n<\/tr>\n<tr>\n<td>\u51ac\u5b63\u5236\u70ed\u4e0d\u8db3<\/td>\n<td>\u4e3b\u673a\u9009\u578b\u504f\u5c0f\u3001\u6d41\u91cf\u4e0d\u8db3<\/td>\n<td>\u68c0\u67e5\u4e3b\u673a\u529f\u7387\u3001\u7ba1\u5f84<\/td>\n<\/tr>\n<tr>\n<td>\u98ce\u76d8\u7ed3\u9732\u6ef4\u6c34<\/td>\n<td>\u4fdd\u6e29\u4e0d\u826f\u3001\u6392\u6c34\u4e0d\u7545<\/td>\n<td>\u4fee\u590d\u4fdd\u6e29\u3001\u758f\u901a\u6392\u6c34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"note\">8.2 \u7cfb\u7edf\u6027\u95ee\u9898\u6839\u6e90\uff08\u8bbe\u8ba1\u9636\u6bb5\u9884\u9632\uff09\uff1a\u7f13\u51b2\u6c34\u7bb1\u5bb9\u91cf\u4e0d\u8db3 \/ \u63a5\u7ba1\u9519\u8bef\uff08\u77ed\u8def\uff09\/ \u7ba1\u5f84\u504f\u5c0f \/ \u672a\u505a\u6c34\u529b\u5e73\u8861 \/ <b>\u98ce\u76d8\u4fdd\u6e29\u4e0d\u826f<\/b> \/ <b>\u6c34\u6cf5\u65e0\u8054\u52a8<\/b>\u3002\u5176\u4e2d\"\u5bb9\u91cf\u4e0d\u8db3\"\u7684\u5904\u7f6e\u539f\u5219\uff1a<b>\u4e8c\u6b21\u7cfb\u7edf\u6216\u4e00\u6b21\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u65f6\u6309\u6807\u51c6\u914d\u6c34\u7bb1\uff1b\u4e00\u6b21\u7cfb\u7edf\u4f18\u5148\u589e\u5927\u4e3b\u7ba1\u7ba1\u5f84<\/b>\uff0c\u4e0d\u8981\u4e00\u5f8b\u52a0\u6c34\u7bb1\u3002<\/div>\n<h3>8.3 \u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u7ef4\u4fdd\u9879\u76ee<\/th>\n<th>\u5468\u671f<\/th>\n<th>\u5185\u5bb9<\/th>\n<\/tr>\n<tr>\n<td>\u8fc7\u6ee4\u5668\u6e05\u6d17<\/td>\n<td>\u6bcf\u5b63<\/td>\n<td>\u6e05\u6d17 Y \u578b\u8fc7\u6ee4\u5668<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u6c34\u8d28\u68c0\u67e5<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5 PH \u503c\u3001\u6d4a\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6cf5\u8fd0\u884c\u68c0\u6d4b<\/td>\n<td>\u6bcf\u5e74<\/td>\n<td>\u68c0\u67e5\u566a\u97f3\u3001\u632f\u52a8\u3001\u7535\u6d41<\/td>\n<\/tr>\n<tr>\n<td>\u8054\u52a8\u529f\u80fd\u6d4b\u8bd5\u3010\u65b0\u589e\u3011<\/td>\n<td>\u6bcf\u534a\u5e74<\/td>\n<td>\u6a21\u62df\u5ba4\u6e29\u53d8\u5316\uff0c\u6d4b\u8bd5\u6c34\u6cf5\u548c\u4e3b\u673a\u8054\u52a8\u54cd\u5e94<\/td>\n<\/tr>\n<tr>\n<td>\u7ba1\u9053\u4fdd\u6e29\u68c0\u67e5\u3010\u65b0\u589e\u3011<\/td>\n<td>\u6bcf\u5e74\u5165\u590f\u524d<\/td>\n<td>\u68c0\u67e5\u98ce\u76d8\u4fdd\u6e29\u5c42\u6709\u65e0\u7834\u635f\u3001\u8001\u5316<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"p9\">\u4e5d\u3001\u63a7\u5236\u7cfb\u7edf\u6df1\u5ea6\u89e3\u6790\u4e0e\u8054\u52a8\u8c03\u8bd5\u6807\u51c6<\/h2>\n<h3>9.1 \u63a7\u5236\u7c7b\u578b\u6f14\u8fdb<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u63a7\u5236\u7c7b\u578b<\/th>\n<th>\u8282\u80fd\u6548\u679c<\/th>\n<th>\u5ba2\u6237\u4ef7\u503c<\/th>\n<\/tr>\n<tr>\n<td>\u624b\u52a8\u9600\u63a7\u5236<\/td>\n<td>\u65e0<\/td>\n<td>\u4ec5\u6ee1\u8db3\u57fa\u7840\u5f00\u5173<\/td>\n<\/tr>\n<tr>\n<td>\u6e29\u63a7\u9600\u63a7\u5236<\/td>\n<td>\u8282\u80fd 5%\u201310%<\/td>\n<td>\u5404\u623f\u95f4\u72ec\u7acb\u63a7\u6e29<\/td>\n<\/tr>\n<tr>\n<td><b>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/b><\/td>\n<td><b>\u8282\u80fd 10%\u201325%<\/b><\/td>\n<td>\u907f\u514d\u65e0\u6548\u4ea7\u70ed\uff08\u63a8\u8350\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u667a\u80fd\u8054\u52a8\u7cfb\u7edf<\/td>\n<td>\u8282\u80fd 15%\u201330%<\/td>\n<td>\u4e00\u952e\u573a\u666f\u3001\u5206\u57df\u5206\u65f6<\/td>\n<\/tr>\n<tr>\n<td>\u5168\u5c4b\u5168\u611f 3.0<\/td>\n<td>\u8282\u80fd 20%+<\/td>\n<td>\u81ea\u52a8\u5316\u8fd0\u884c\u3001\u5168\u7ef4\u8212\u9002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>9.2 \u6807\u51c6\u8054\u52a8\u6d41\u7a0b\uff08\u4e24\u8054\u4f9b\uff09<\/h3>\n<p>\u5ba4\u6e29\u4f20\u611f\u5668\u68c0\u6d4b \u2192 \u5ba4\u6e29\u504f\u79bb\u8bbe\u5b9a \u2192 \u8054\u52a8\u542f\u52a8\u53d8\u9891\u6c34\u6cf5 \u2192 \u68c0\u6d4b\u6c34\u6d41\u5efa\u7acb \u2192 \u8054\u52a8\u542f\u52a8\u4e3b\u673a \u2192 \u5ba4\u6e29\u8fbe\u6807 \u2192 \u8054\u52a8\u505c\u6b62\u4e3b\u673a \u2192 \u5ef6\u65f6\u505c\u6b62\u6c34\u6cf5\u3002<\/p>\n<div class=\"warn\">\u5e38\u89c1\u9519\u8bef\uff1a\u274c \u6c34\u6cf5\u4e0d\u8054\u52a8\uff0824h \u8f6c\uff0c\u5e74\u6d6a\u8d39 300\u2013800 \u5143\uff09\uff1b\u274c \u4e3b\u673a\u6309\u6c34\u6e29\u542f\u505c\uff08\u5ba4\u6e29\u8fbe\u6807\u8fd8\u5728\u70e7\uff09\uff1b\u274c \u6e29\u63a7\u4e0e\u4e3b\u673a\u5404\u81ea\u4e3a\u653f\u3002<\/div>\n<h3>9.3 \u65e5\u7acb\u6c34\u5885\u9002 VF \u8054\u52a8\u63a7\u5236\u7279\u8272<\/h3>\n<ul>\n<li>\u81ea\u9002\u5e94\u53d8\u9891\u6280\u672f\uff1a\u538b\u7f29\u673a\u3001\u6c34\u6cf5\u81ea\u9002\u5e94\u53d8\u9891\u63a7\u5236<\/li>\n<li>\u667a\u80fd PTT \u9664\u971c\uff1a\u7ed3\u971c\u51cf\u5c11\u81f3 1\/3<\/li>\n<li>\u53d8\u6c34\u6e29\u63a7\u5236\uff1a\u5236\u51b7\u51fa\u6c34 5\u201325\u2103 \/ \u5236\u70ed\u51fa\u6c34 20\u201355\u2103<\/li>\n<li>\u4e94\u91cd\u81ea\u52a8\u9632\u51bb\u4fdd\u62a4<\/li>\n<\/ul>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxycxt-ldjxsyt.jpg\" alt=\"\u6c34\u5885\u9002VF\u4e00\u6b21\u7cfb\u7edf-\u8054\u52a8\u63a5\u7ebf\u793a\u610f\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u6c34\u5885\u9002 VF \u4e00\u6b21\u7cfb\u7edf\u00b7\u8054\u52a8\u63a5\u7ebf\u793a\u610f\u56fe<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxycxt-csxf-jkp-ldjxsyt.jpg\" alt=\"\u6c34\u5885\u9002VF\u4e00\u6b21\u7cfb\u7edf-\u9664\u6e7f\u65b0\u98ce-\u96c6\u63a7\u5c4f-\u8054\u52a8\u63a5\u7ebf\u793a\u610f\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u6c34\u5885\u9002 VF \u4e00\u6b21\u7cfb\u7edf\u00b7\u9664\u6e7f\u65b0\u98ce + \u96c6\u63a7\u5c4f\u8054\u52a8\u63a5\u7ebf<\/div>\n<\/p>\n<\/div>\n<\/div>\n<h3>9.4 \u6c34\u5885\u9002 VF \u8fdb\u9636\uff1a\u4ece\u4e24\u8054\u4f9b\u5230\"\u4e94\u6052\u7cfb\u7edf\"<\/h3>\n<p>\u4e24\u8054\u4f9b\u89e3\u51b3\u7684\u662f<strong>\u6052\u6e29<\/strong>\uff08\u590f\u5b63\u5236\u51b7 + \u51ac\u5b63\u5730\u6696\uff09\u3002\u800c\u771f\u6b63\u7684\u8212\u9002\u5347\u7ea7\u2014\u2014<strong>\u4e94\u6052\uff08\u6052\u6e29 \u00b7 \u6052\u6e7f \u00b7 \u6052\u6c27 \u00b7 \u6052\u6d01 \u00b7 \u6052\u9759\uff09<\/strong>\u2014\u2014\u5e76\u4e0d\u662f\u6362\u6389\u4e24\u8054\u4f9b\uff0c\u800c\u662f\u5728\u6c34\u5885\u9002 VF \u8fd9\u4e2a\u5e95\u5ea7\u4e0a<strong>\u53e0\u52a0\u6a21\u5757<\/strong>\uff1a<\/p>\n<table>\n<tbody>\n<tr>\n<th>\u4e94\u6052\u7ef4\u5ea6<\/th>\n<th>\u53e0\u52a0\u6a21\u5757<\/th>\n<th>\u4e0e\u6c34\u5885\u9002 VF \u7684\u5173\u7cfb<\/th>\n<\/tr>\n<tr>\n<td>\u6052\u6e29<\/td>\n<td>\u4e24\u8054\u4f9b\u4e3b\u673a\uff08\u5df2\u6709\uff09<\/td>\n<td>\u6c34\u5885\u9002 VF \u4e00\u6b21\u7cfb\u7edf\u76f4\u63a5\u63d0\u4f9b<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6e7f \/ \u6052\u6c27<\/td>\n<td>\u65e5\u7acb\u9664\u6e7f\u65b0\u98ce\u7cfb\u7edf<\/td>\n<td>\u63a5\u5165 VF \u96c6\u63a7\u5c4f\uff0c\u4e0e\u4e3b\u673a\u8054\u52a8\uff08\u89c1\u4e0a\u56fe\u00b7\u9664\u6e7f\u65b0\u98ce + \u96c6\u63a7\u5c4f\u8054\u52a8\u63a5\u7ebf\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u6d01\uff08\u6052\u51c0\uff09<\/td>\n<td>\u65b0\u98ce\u51c0\u5316 \/ \u5168\u5c4b\u8fc7\u6ee4<\/td>\n<td>\u968f\u9664\u6e7f\u65b0\u98ce\u4e00\u4f53\u5f15\u5165\uff0c\u8fc7\u6ee4 PM2.5 \u4e0e\u8fc7\u654f\u6e90<\/td>\n<\/tr>\n<tr>\n<td>\u6052\u9759<\/td>\n<td>\u5168\u5305\u5f0f\u98ce\u673a\u76d8\u7ba1 + \u5c4f\u853d\u6c34\u6cf5<\/td>\n<td>\u590d\u7528\u65e5\u7cfb\u5185\u673a\u5c01\u88c5\u6280\u672f\uff08\u89c1 1.2\uff09\uff0c\u4f4e\u566a\u8fd0\u884c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"note\">\u9f99\u8109\u505a\u6cd5\uff1a\u4ee5\u5168\u53d8\u9891\u6c34\u5885\u9002 VF \u4e24\u8054\u4f9b\u4e3a\u5e95\u5ea7\uff0c\u53e0\u52a0\u65e5\u7acb\u9664\u6e7f\u65b0\u98ce + \u5168\u5c4b\u96c6\u63a7\u5c4f\uff0c\u5373\u53ef\u5347\u7ea7\u4e3a\"\u4e94\u6052\u7cfb\u7edf\"\u3002\u6838\u5fc3\u4e0d\u662f\u53e6\u8d77\u4e00\u5957\u7cfb\u7edf\uff0c\u800c\u662f<strong>\u4e00\u5957\u6c34\u7cfb\u7edf + \u6a21\u5757\u5316\u53e0\u52a0<\/strong>\u2014\u2014\u8fd9\u4e5f\u6b63\u662f\u4e0a\u65b9\"\u9664\u6e7f\u65b0\u98ce + \u96c6\u63a7\u5c4f\u8054\u52a8\u63a5\u7ebf\u56fe\"\u6240\u5c55\u793a\u7684\u63a7\u5236\u4e2d\u67a2\u3002\u5bf9\u5ba2\u6c9f\u901a\u65f6\uff0c\u5148\u8bb2\u6e05\u4e24\u8054\u4f9b\uff08\u6052\u6e29\u5e95\u5ea7\uff09\uff0c\u518d\u8bb2\u4e94\u6052\u662f\u53e0\u52a0\u5347\u7ea7\uff0c\u907f\u514d\u4e00\u4e0a\u6765\u5c31\u88ab\"\u4e94\u6052\"\u9ad8\u4ef7\u5413\u9000\u3002<\/div>\n<h2 id=\"p10\">\u5341\u3001\u65b9\u6848\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\uff08\u6280\u672f G \/ \u7ecf\u6d4e E \/ \u64cd\u4f5c O\uff09<\/h2>\n<div class=\"warn\">\u26a0\ufe0f <b>\u672f\u8bed\u533a\u5206\uff08\u91cd\u8981\uff09\uff1a<\/b>\u672c\u6e05\u5355\u7684\u300cG\/E\/O \u4e09\u7ef4\u9a8c\u6536\u300d\u4e0e\u516c\u53f8\u6218\u7565\u5c42\u9762\u7684 <b>GEO\uff08\u751f\u6210\u5f0f\u5f15\u64ce\u4f18\u5316\uff0cGenerative Engine Optimization\uff09<\/b> \u662f\u540c\u5b57\u4e0d\u540c\u4e49\u7684\u4e24\u4e2a\u6982\u5ff5\uff0c\u7981\u6b62\u6df7\u7528\u3002\u5bf9\u5916\/\u5bf9\u5185\u5e94\u79f0\u300c\u65b9\u6848\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u300d\uff0c\u4e0d\u5f97\u7b80\u79f0\u4e3a\u300cGEO \u9a8c\u6536\u300d\u3002<\/div>\n<h3>10.1 \u6280\u672f\u6b63\u786e\u6027\uff08G\uff09\u2014\u201410 \u9879\u5fc5\u5ba1\uff08\u8282\u9009\uff09<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u9879<\/th>\n<th>\u5ba1\u6838\u6807\u51c6<\/th>\n<\/tr>\n<tr>\n<td>G1 \u7cfb\u7edf\u5f62\u5f0f<\/td>\n<td>\u4f18\u5148\u4e00\u6b21\u7cfb\u7edf\uff1b\u4e8c\u6b21\u7cfb\u7edf\u987b\u63d0\u4f9b\u6b63\u5f53\u7406\u7531\uff08\u672b\u7aef&gt;15 \u53f0\u6216\u7ba1\u8def&gt;200m\uff09<\/td>\n<\/tr>\n<tr>\n<td>G2 \u7f13\u51b2\u6c34\u7bb1<\/td>\n<td>\u7cfb\u7edf\u6c34\u91cf\u8fbe\u6807\u65f6\u4e0d\u9700\u8981\uff08\u2265 \u5f00\u5229 3.25 \/ \u65e5\u7acb 2 L\/kW\uff09<\/td>\n<\/tr>\n<tr>\n<td>G3 \u7ba1\u5f84\u8bbe\u8ba1<\/td>\n<td>\u4e3b\u7ba1 De32\/De40\uff0c\u652f\u7ba1 De20<\/td>\n<\/tr>\n<tr>\n<td>G5 \u98ce\u76d8\u9009\u578b<\/td>\n<td>\u5168\u5305\u5f0f\/\u5c01\u88c5\u5f0f\uff08\u522b\u5885\u7981\u7528\u534a\u5305\u5f0f\uff09<\/td>\n<\/tr>\n<tr>\n<td>G6 \u4e3b\u673a\u9009\u578b<\/td>\n<td>\u6309\u5730\u6696\u8bbe\u8ba1\u8d1f\u8377 100W\/\u33a1<\/td>\n<\/tr>\n<tr>\n<td>G8 \u8054\u52a8\u63a7\u5236<\/td>\n<td>\u5ba4\u6e29\u2192\u6c34\u6cf5\u2192\u4e3b\u673a\u8054\u52a8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>10.2 \u7ecf\u6d4e \/ \u64cd\u4f5c\uff08E\/O\uff09<\/h3>\n<p><b>E\uff08\u7ecf\u6d4e 5 \u9879\uff09\uff1a<\/b>\u521d\u6295\u8d44\u5bf9\u6bd4\u3001\u8fd0\u884c\u8d39\u7528\u4f30\u7b97\u3001\u56de\u672c\u5468\u671f\u3001\u65e0\u5197\u4f59\u914d\u7f6e\u3001\u7ef4\u4fdd\u6210\u672c\u9884\u4f30\u3002<br \/><b>O\uff08\u64cd\u4f5c 5 \u9879\uff09\uff1a<\/b>\u65bd\u5de5\u53ef\u884c\u6027\u3001\u5b89\u88c5\u5de5\u671f\u3001\u5907\u4ef6\u53ef\u91c7\u8d2d\u6027\u3001\u552e\u540e\u54cd\u5e94\u80fd\u529b\u3001\u5ba2\u6237\u77e5\u60c5\u786e\u8ba4\u3002<\/p>\n<h2 id=\"p11\">\u5341\u4e00\u3001\u6210\u90fd\u672c\u5730\u5b9e\u6218\u6848\u4f8b\u96c6<\/h2>\n<h3>11.1 \u6848\u4f8b\u4e00\uff1a\u8f9b\u603b 450\u33a1 \u522b\u5885\u00b7\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u4fe1\u606f<\/th>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u65b9\u6848<\/td>\n<td>\u6c34\u5885\u9002 VF \u5168\u53d8\u9891 + \u4e00\u6b21\u7cfb\u7edf\u65e0\u6c34\u7bb1 + \u5168\u5305\u5f0f\u98ce\u76d8<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u4eae\u70b9<\/td>\n<td>\u6309\u5730\u6696\u8d1f\u8377\u914d\u7f6e\u4e3b\u673a\uff08100W\/\u33a1\uff09\uff0c\u7a7a\u8c03\u4fa7\u6309\u5b9e\u9645\u9700\u6c42<\/td>\n<\/tr>\n<tr>\n<td>\u8fd0\u884c\u6570\u636e<\/td>\n<td>\u51ac\u5b63\u5730\u6696\u6708\u5747\u8fd0\u884c\u8d39\u7ea6 1,800 \u5143\uff0c\u6bd4\u540c\u9762\u79ef\u71c3\u6c14\u65b9\u6848\u7701 60%+<\/td>\n<\/tr>\n<tr>\n<td>\u56de\u8bbf<\/td>\n<td>\u8fde\u7eed 4 \u4e2a\u91c7\u6696\u5b63\uff0c\u7cfb\u7edf\u7a33\u5b9a\u65e0\u91cd\u5927\u6545\u969c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>11.2 \u6848\u4f8b\u4e8c\uff1a\u5468\u8001\u5e08 160\u33a1 \u5e73\u5c42\u00b7\u6c34\u7cfb\u7edf\u4f18\u5316<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u4fe1\u606f<\/th>\n<\/tr>\n<tr>\n<td>\u539f\u75db\u70b9<\/td>\n<td>26kW \u5e38\u89c4\u58c1\u6302\u7089 + \u6c34\u5730\u6696\uff0c\u51ac\u5b63\u6708\u71c3\u6c14\u8d39\u7ea6 1,800 \u5143\uff1b\u5404\u623f\u95f4\u6e29\u5dee 4\u2103+<\/td>\n<\/tr>\n<tr>\n<td>\u5347\u7ea7\u65b9\u6848<\/td>\n<td>\u6c34\u5885\u9002 VF \u6574\u673a\u7248\uff08\u4e3b\u673a\u5185\u7f6e\u53d8\u9891\u6cf5\uff0c\u4e00\u6b21\u7cfb\u7edf\uff09+ \u5168\u5c4b\u6c34\u529b\u5e73\u8861\u8c03\u8bd5<\/td>\n<\/tr>\n<tr>\n<td>\u6539\u9020\u6548\u679c<\/td>\n<td>\u6708\u8fd0\u884c\u8d39\u964d\u81f3\u7ea6 1,000 \u5143\uff08\u7701 40%+\uff09\uff1b\u5404\u623f\u95f4\u6e29\u5dee\u7f29\u5c0f\u5230 \u00b11\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>11.3 \u6848\u4f8b\u4e09\uff1a\u6881\u603b 350\u33a1 \u529e\u516c+\u4f4f\u5b85\u00b7\u6df7\u5408\u70ed\u6e90<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>\u4fe1\u606f<\/th>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u65b9\u6848<\/td>\n<td>\u529e\u516c\u533a\u72ec\u7acb\u51b7\u51dd\u7089 + \u4f4e\u6e29\u6696\u6c14\u7247\uff1b\u4f4f\u5b85\u533a\u72ec\u7acb\u6c34\u5885\u9002 VF \u4e00\u6b21\u7cfb\u7edf<\/td>\n<\/tr>\n<tr>\n<td>\u6539\u9020\u6548\u679c<\/td>\n<td>\u529e\u516c\u533a\u6708\u8d39\u7ea6 800 \u5143\uff08\u4ec5\u5de5\u4f5c\u65e5\uff09\uff1b\u4f4f\u5b85\u533a\u6708\u7535\u8d39\u7ea6 1,200 \u5143\uff1b\u603b\u8ba1\u7701 55%+<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>11.4 \u6210\u90fd\u672c\u5730\u9009\u578b\u53c2\u8003 + \u8d1f\u8377\u53e3\u5f84\u8bf4\u660e<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u53c2\u6570<\/th>\n<th>\u63a8\u8350\u503c<\/th>\n<th>\u8bf4\u660e<\/th>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/td>\n<td>100\u2013110 W\/\u33a1<\/td>\n<td>\u6210\u90fd\u8282\u80fd\u5efa\u7b51\u6807\u51c6\uff08\u5de5\u7a0b\u53d6\u503c\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u7a7a\u8c03\u8bbe\u8ba1\u51b7\u8d1f\u8377<\/td>\n<td>120\u2013140 W\/\u33a1<\/td>\n<td>\u56fd\u5bb6\u6807\u51c6\u5236\u51b7\u89c4\u8303\uff08\u5de5\u7a0b\u53d6\u503c\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6a21\u5757\u9009\u578b\u70ed\u6307\u6807<\/td>\n<td>110\u2013120 W\/\u33a1<\/td>\n<td>\u65e5\u7acb\u6210\u90fd\u5206\u516c\u53f8\u8bbe\u8ba1\u6307\u5bfc\u4e66<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u4f4e\u73af\u6e29\u8fd0\u884c<\/td>\n<td>-5\u2103 \u4ee5\u4e0a<\/td>\n<td>\u6210\u90fd\u7a7a\u6c14\u80fd\u5145\u5206\u80dc\u4efb<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"card\">\n<h4>\u4e09\u5957\u8d1f\u8377\u53e3\u5f84\u5b9a\u4e49\u5361\uff08\u5fc5\u8bfb \u00b7 \u7981\u6b62\u6df7\u7528\uff09<\/h4>\n<table>\n<tbody>\n<tr>\n<th>\u53e3\u5f84<\/th>\n<th>\u51b3\u7b56\u7528\u9014<\/th>\n<th>\u6210\u90fd\u5178\u578b\u503c<\/th>\n<th>\u6570\u636e\u51fa\u5904<\/th>\n<\/tr>\n<tr>\n<td>\u2460 \u7406\u8bba\u503c<\/td>\n<td>\u8282\u80fd\u5bf9\u6807 \/ \u5b8f\u89c2\u4f30\u7b97<\/td>\n<td>50\u201380 W\/\u33a1<\/td>\n<td>GB 50736\uff08\u8282\u80fd\u5efa\u7b51\u8fde\u7eed\u91c7\u6696\u7406\u8bba\u503c\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u2461 \u6708\u5747\u4f7f\u7528\u503c<\/td>\n<td><b>\u6708\u5747\u8d39\u7528\u6d4b\u7b97<\/b><\/td>\n<td>\u51b7 46 \/ \u70ed 45 W\/\u33a1<\/td>\n<td>\u300a\u5168\u5e74\u8d1f\u8377\u8ba1\u7b97\u300b7 \u6708\u51b7\u6307\u6807 46\u300112 \u6708\u70ed\u6307\u6807 45<\/td>\n<\/tr>\n<tr>\n<td>\u2462 \u8bbe\u8ba1\u5cf0\u503c<\/td>\n<td><b>\u4e3b\u673a\u914d\u578b<\/b><\/td>\n<td>\u51b7 88\u2013108 \/ \u70ed 67\u201387 W\/\u33a1<\/td>\n<td>\u540c\u4e0a\uff1a\u65e0\u6237\u95f4\u4f20\u70ed 88\/67\uff0c\u6709\u6237\u95f4\u4f20\u70ed 108\/87<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"kv\" style=\"margin-top:10px\">\u26a0\ufe0f <b>\u4e3a\u4ec0\u4e48\u4e0d\u80fd\u5408\u4e00\uff1f<\/b>\u7528\"\u6708\u5747 46\"\u53bb\u914d\u578b\u4f1a\u9009\u5c0f\u4e3b\u673a\uff08\u6781\u7aef\u5929\u4e0d\u591f\u7528\uff09\uff1b\u7528\"\u8bbe\u8ba1 110\"\u53bb\u7b97\u6708\u8d39\u4f1a\u5413\u8dd1\u5ba2\u6237\uff08\u5b9e\u9645\u8fdc\u4f4e\u4e8e\u6b64\uff09\u3002\u65b9\u6848\u4e2d<strong>\u5fc5\u987b\u6ce8\u660e\u6240\u7528\u53e3\u5f84<\/strong>\u3002<\/p>\n<\/div>\n<p><img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-luxi-yimo-designer-hvac-floor-heating-detail-05.jpg\" alt=\"\u6696\u901a\u8bbe\u8ba1\u56fe-\u5730\u6696\u94fa\u8bbe\u5927\u6837\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u5730\u6696\u94fa\u8bbe\u5927\u6837\u56fe\uff08\u6848\u4f8b\u65bd\u5de5\u53c2\u8003\uff09<\/div>\n<h2 id=\"p12\">\u5341\u4e8c\u3001\u8bbe\u8ba1\u9636\u6bb5\u81ea\u67e5\u6838\u67e5\u8868<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u9636\u6bb5<\/th>\n<th>\u6838\u67e5\u9879\uff08\u8282\u9009\uff09<\/th>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u8f93\u5165<\/td>\n<td>\u5efa\u7b51\u56fe\u7eb8 \/ \u5ba2\u6237\u9700\u6c42 \/ \u5916\u673a\u4f4d\u6761\u4ef6 \/ \u5730\u6696\u533a\u57df \/ \u751f\u6d3b\u70ed\u6c34\u9700\u6c42<\/td>\n<\/tr>\n<tr>\n<td>\u7cfb\u7edf\u8bbe\u8ba1<\/td>\n<td>\u4e00\u6b21\u7cfb\u7edf\u9996\u9009 \/ \u514d\u6c34\u7bb1\u6838\u7b97 \/ \u4e3b\u673a\u6309\u5730\u6696\u8d1f\u8377 \/ \u4e3b\u7ba1 De32\u2013De40 \/ \u5168\u5305\u5f0f\u98ce\u76d8 \/ \u8054\u52a8\u903b\u8f91<\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u6761\u4ef6<\/td>\n<td>\u5916\u673a\u4f4d\u901a\u98ce \/ \u6392\u6c34\u5761\u5ea6 \/ \u7ba1\u9053\u8d70\u5411 \/ \u4e09\u9053\u5bc6\u5c01\u4ea4\u5e95 \/ \u4e09\u91cd\u4fdd\u538b\u8ba1\u5212<\/td>\n<\/tr>\n<tr>\n<td>\u4ea4\u4ed8\u7269<\/td>\n<td>\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u542b\u8054\u52a8\uff09\/ \u8bbe\u5907\u6e05\u5355 \/ \u7ba1\u9053\u8def\u7531\u56fe \/ \u5de5\u827a\u8bf4\u660e \/ \u80fd\u8017\u4f30\u7b97 \/ \u7ef4\u4fdd\u8ba1\u5212 \/ \u4e09\u7ef4\u9a8c\u6536\u8bb0\u5f55<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"p13\">\u5341\u4e09\u3001\u552e\u540e\u95ed\u73af\u5904\u7406\u6d41\u7a0b\u4e0e\u5ba2\u8bc9\u5e94\u5bf9<\/h2>\n<h3>13.1 \u95ee\u9898\u5206\u7ea7\u54cd\u5e94<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u7ea7\u522b<\/th>\n<th>\u95ee\u9898\u7c7b\u578b<\/th>\n<th>\u54cd\u5e94<\/th>\n<\/tr>\n<tr>\n<td>P0 \u7d27\u6025<\/td>\n<td>\u6362\u70ed\u5668\u51bb\u88c2\u3001\u5927\u91cf\u6f0f\u6c34\u3001\u7cfb\u7edf\u505c\u673a<\/td>\n<td>2 \u5c0f\u65f6\u5185\u5230\u573a\uff0c24h \u5185\u51fa\u65b9\u6848<\/td>\n<\/tr>\n<tr>\n<td>P1 \u4e25\u91cd<\/td>\n<td>\u9891\u7e41\u542f\u505c\u3001\u5236\u70ed\u4e0d\u8db3\u3001\u62a5\u9519<\/td>\n<td>4 \u5c0f\u65f6\u5185\u54cd\u5e94\uff0c72h \u5185\u89e3\u51b3<\/td>\n<\/tr>\n<tr>\n<td>P2 \u4e00\u822c<\/td>\n<td>\u566a\u97f3\u3001\u4e2a\u522b\u7ed3\u9732\u3001\u9707\u52a8<\/td>\n<td>24 \u5c0f\u65f6\u5185\u54cd\u5e94\uff0c5 \u5de5\u4f5c\u65e5\u89e3\u51b3<\/td>\n<\/tr>\n<tr>\n<td>P3 \u54a8\u8be2<\/td>\n<td>\u4f7f\u7528\u7591\u95ee\u3001\u4fdd\u517b\u63d0\u9192<\/td>\n<td>48 \u5c0f\u65f6\u5185\u56de\u590d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>13.2 \u516d\u6b65\u95ed\u73af\u6d41\u7a0b<\/h3>\n<p>\u5ba2\u6237\u62a5\u4fee \u2192 \u7ebf\u4e0a\u9884\u5224 \u2192 \u6d3e\u5355\u5e26\u6599\u4e0a\u95e8 \u2192 \u73b0\u573a\u6392\u67e5\u5904\u7406\uff08\u586b\u300a\u7ef4\u4fee\u8bb0\u5f55\u8868\u300b\uff09\u2192 3 \u65e5\u5185\u56de\u8bbf\u786e\u8ba4 \u2192 \u77e5\u8bc6\u95ed\u73af\u56de\u4f20\u77e5\u8bc6\u5e93\u3002<\/p>\n<div class=\"note\">\u6bcf\u6b21\u552e\u540e\u5fc5\u987b\u5b8c\u6210\u77e5\u8bc6\u95ed\u73af\uff1a\u6545\u969c\u63cf\u8ff0 \/ \u6839\u56e0\u5206\u6790\uff08\u8bbe\u8ba1\u00b7\u5b89\u88c5\u00b7\u4f7f\u7528\u00b7\u4ea7\u54c1\uff09\/ \u5904\u7406\u8fc7\u7a0b \/ \u9884\u9632\u5efa\u8bae \/ \u5173\u8054\u65b9\u6848\u7f16\u53f7\u3002\u6545\u969c\u6570\u636e\u76f4\u63a5\u89e6\u53d1\u552e\u540e\u95ed\u73af\uff0c\u6b63\u5e38\u4f7f\u7528\u6570\u636e\u4f5c\u4e3a\u80fd\u8017\u57fa\u51c6\u7528\u4e8e\u540e\u7eed\u65b9\u6848\u4f18\u5316\u3002<\/div>\n<h2 id=\"energy\">\u9644\uff1a\u80fd\u6548\u4e0e\u8fd0\u884c\u8d39\u7528\uff08\u6210\u90fd\u5b9e\u6d4b\u6570\u636e\uff09<\/h2>\n<p>\u4ee5\u4e0b\u6570\u636e\u6765\u81ea\u6210\u90fd\u67d0 178\u33a1 \u9ad8\u5c42\u4f4f\u5b85\u300a\u5168\u5e74\u8d1f\u8377\u8ba1\u7b97\u300b\u5b9e\u6d4b\uff0c\u6f14\u793a\u4e09\u5957\u8d1f\u8377\u53e3\u5f84\u4e0e\u771f\u5b9e\u8fd0\u884c\u8d39\u7528\uff0c\u4f9b\u65b9\u6848\u6d4b\u7b97\u5f15\u7528\u3002<\/p>\n<table>\n<tbody>\n<tr>\n<th>\u6708\u4efd<\/th>\n<th>\u51b7\u6307\u6807 (W\/\u33a1)<\/th>\n<th>\u70ed\u6307\u6807 (W\/\u33a1)<\/th>\n<th>\u5f53\u6708\u8fd0\u884c\u8d39\uff0824h \u5168\u5f00\u6781\u7aef\u4e0a\u9650\uff09<\/th>\n<\/tr>\n<tr>\n<td>7 \u6708\uff08\u5236\u51b7\u5cf0\u503c\uff09<\/td>\n<td>46<\/td>\n<td>\u2014<\/td>\n<td>\u7ea6 1,100 \u5143<\/td>\n<\/tr>\n<tr>\n<td>12 \u6708\uff08\u5236\u70ed\u5cf0\u503c\uff09<\/td>\n<td>\u2014<\/td>\n<td>45<\/td>\n<td>\u7ea6 1,014 \u5143<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u65e5\u9010\u65f6\u6700\u5927\uff08\u65e0\u6237\u95f4\u4f20\u70ed\uff09<\/td>\n<td>88<\/td>\n<td>67<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>\u8bbe\u8ba1\u65e5\u9010\u65f6\u6700\u5927\uff08\u6709\u6237\u95f4\u4f20\u70ed\uff09<\/td>\n<td>108<\/td>\n<td>87<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"warn\">\u26a0\ufe0f \u5bf9\u5ba2\u5f15\u7528\"1,100 \u5143\/\u6708\uff087 \u6708\uff09\"\u65f6\uff0c\u5fc5\u987b\u6807\u6ce8\u8fd9\u662f <b>24h \u5168\u5f00\u6781\u7aef\u4e0a\u9650<\/b>\uff0c\u5b9e\u9645\u95f4\u6b47\u4f7f\u7528\u66f4\u4f4e\u3002\u80fd\u8017\u57fa\u51c6\u4ecd\u6309\"\u6708\u5747\u4f7f\u7528\u503c\"\u6d4b\u7b97\uff0c<b>\u4e25\u7981\u7528\u8bbe\u8ba1\u5cf0\u503c\u53bb\u7b97\u6708\u8d39<\/b>\u3002<\/div>\n<div class=\"grid2\">\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxsfsycxtylt.jpg\" alt=\"\u6c34\u5885\u9002VF\u53cc\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u6c34\u5885\u9002 VF \u53cc\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u9ad8\u80fd\u6548\u4e3b\u673a\uff09<\/div>\n<\/p>\n<\/div>\n<div>\n    <img decoding=\"async\" class=\"diagram\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dnmrdh-boxldkzjxt-1.jpg\" alt=\"\u5730\u6696\u66fc\u745e\u5fb7H-BOX\u8054\u52a8\u63a7\u5236\u63a5\u7ebf\u56fe\u4e00\"><\/p>\n<div class=\"fig\">\u56fe\uff1a\u5730\u6696\u8054\u52a8\u63a7\u5236\u63a5\u7ebf\u56fe\uff08\u8054\u52a8\u8c03\u8bd5\u4f9d\u636e\uff09<\/div>\n<\/p>\n<\/div>\n<\/div>\n<h2 id=\"faq\">\u5e38\u89c1\u95ee\u9898 FAQ<\/h2>\n<details class=\"faq\">\n<summary>\u4e8c\u8054\u4f9b\u548c\u4e2d\u592e\u7a7a\u8c03\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/summary>\n<p>\u4e2d\u592e\u7a7a\u8c03\u591a\u6307\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\uff0c\u4ec5\u89e3\u51b3\u5236\u51b7\uff08\u90e8\u5206\u5e26\u5236\u70ed\uff09\u3002\u4e8c\u8054\u4f9b\u662f\u4e00\u5957\u6c34\u7cfb\u7edf\u4e3b\u673a\uff0c\u590f\u5929\u51fa\u51b7\u6c34\u8d70\u98ce\u673a\u76d8\u7ba1\u5236\u51b7\u3001\u51ac\u5929\u51fa\u70ed\u6c34\u8d70\u5730\u6696\u7ba1\u5236\u70ed\uff0c\u4e00\u5957\u7cfb\u7edf\u89e3\u51b3\u51b7\u6696\uff0c\u51fa\u98ce\u66f4\u67d4\u548c\u3001\u51ac\u5b63\u5730\u6696\u66f4\u8212\u9002\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u4e00\u5b9a\u8981\u52a0\u7f13\u51b2\u6c34\u7bb1\u5417\uff1f<\/summary>\n<p>\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u5728\u6c34\u5bb9\u91cf\u8fbe\u6807\uff08\u2265 \u5f00\u5229 3.25 L\/kW \u6216\u65e5\u7acb 2 L\/kW\uff09\u65f6\u4e0d\u9700\u8981\u7f13\u51b2\u6c34\u7bb1\uff1b\u5b9a\u9891\u7cfb\u7edf\u3001\u4e8c\u6b21\u7cfb\u7edf\u3001\u6216\u4e00\u6b21\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u65f6\u624d\u9700\u8981\u3002\u5730\u6696\u56de\u586b\u5c42\u672c\u8eab\u5c31\u662f\u5de8\u5927\u84c4\u70ed\u6c34\u4f53\uff0c\u5e38\u89c1\"\u5fc5\u52a0\u6c34\u7bb1\"\u662f\u5b9a\u9891\u65f6\u4ee3\u7684\u60ef\u6027\u8bef\u89e3\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u65e5\u7acb\u6c34\u5885\u9002 VF \u548c FX \u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/summary>\n<p>\u540c\u5c5e\u65e5\u7acb\u6c34\u5885\u9002\u5168\u53d8\u9891\u6c34\u673a\u4ea7\u54c1\u7ebf\uff0cFX \u662f VF \u7684\u6cf5\u5916\u7f6e\u7248\u672c\uff1a\u4e3b\u673a\u4e0d\u5e26\u53d8\u9891\u6c34\u6cf5\u4e0e\u81a8\u80c0\u7f50\uff0c\u4ef7\u683c\u4f4e\u4e00\u622a\u3002\u6c34\u7cfb\u7edf\u7684\u96be\u70b9\u5728\u6cf5\u7684\u9009\u578b\u3001\u8054\u52a8\u4e0e\u63a7\u5236\u2014\u2014VF \u51fa\u5382\u5c31\u4e00\u4f53\u5316\u914d\u597d\u4e86\uff0cFX \u8fd9\u4e9b\u8981\u7531\u8bbe\u8ba1\u65bd\u5de5\u65b9\u81ea\u5df1\u914d\u3002\u65bd\u5de5\u65b9\u7ecf\u9a8c\u4e0d\u591f\u65f6\uff0c\u6211\u4eec\u5efa\u8bae\u9009 VF\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u6c34\u673a\u662f\u4e0d\u662f\u66f4\u5bb9\u6613\u6f0f\u6c34\uff1f<\/summary>\n<p>\u98ce\u9669\u5ba2\u89c2\u5b58\u5728\uff0c\u4f46\u53ef\u63a7\uff1a\u91c7\u7528\u4f1f\u661f F-PPRCT \/ S3.2 \u54c1\u724c\u7ba1\u9053\u3001\u91d1\u5c5e\u63a5\u5934\u4e09\u9053\u5bc6\u5c01\u5de5\u827a\u3001\u5b89\u88c5\u4e09\u91cd\u4fdd\u538b\u5236\u5ea6\uff0c\u5e76\u628a\u4fdd\u538b\u8bb0\u5f55\u7559\u6863\u3002\u6b63\u89c4\u5de5\u827a\u4e0b\u6f0f\u6c34\u6982\u7387\u6781\u4f4e\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u6210\u90fd\u88c5\u4e8c\u8054\u4f9b\u51ac\u5929\u591f\u7528\u5417\uff1f<\/summary>\n<p>\u6210\u90fd\u5c5e\u590f\u70ed\u51ac\u51b7\u5730\u533a\uff0c\u51ac\u5b63\u6781\u5c11\u4f4e\u4e8e -5\u2103\uff0c\u7a7a\u6c14\u80fd\u70ed\u6cf5\u5145\u5206\u80dc\u4efb\u3002\u6309\u5730\u6696\u8bbe\u8ba1\u8d1f\u8377 100\u2013110 W\/\u33a1 \u914d\u7f6e\u4e3b\u673a\uff0c\u914d\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\uff0c\u51ac\u5b63\u5730\u6696\u7a33\u5b9a\u4e14\u6bd4\u71c3\u6c14\u7701 40% \u4ee5\u4e0a\u3002<\/p>\n<\/details>\n<details class=\"faq\">\n<summary>\u4e8c\u8054\u4f9b\u8fd0\u884c\u8d39\u7528\u5927\u6982\u591a\u5c11\uff1f<\/summary>\n<p>\u4ee5\u6210\u90fd 178\u33a1 \u9ad8\u5c42\u5b9e\u6d4b\uff1a\u8bbe\u8ba1\u5cf0\u503c\u6708\uff087 \u6708\u5236\u51b7 \/ 12 \u6708\u5236\u70ed\uff0924h \u5168\u5f00\u6781\u7aef\u4e0a\u9650\u7ea6 1,100 \/ 1,014 \u5143\uff0c\u5b9e\u9645\u95f4\u6b47\u4f7f\u7528\u66f4\u4f4e\u3002\u5730\u6696\u5b63\u8282\u6bd4\u71c3\u6c14\u65b9\u6848\u7701 40% \u4ee5\u4e0a\u3002<\/p>\n<\/details>\n<h2 id=\"store\">\u95e8\u5e97\u4e0e\u8054\u7cfb<\/h2>\n<div class=\"store\">\n<div class=\"box\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\"><\/p>\n<div class=\"info\">\n<h4>\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/h4>\n<p>\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<\/p>\n<p>\u70ed\u7ebf 028-86131795 \uff5c \u4f59\u6653\u73b2 130-0811-3409 \uff5c \u9ec4\u7ecf\u7406 158-2848-9188<\/p>\n<\/p>\n<\/div>\n<\/div>\n<div class=\"box\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u6210\u534e\u5e97\"><\/p>\n<div class=\"info\">\n<h4>\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/h4>\n<p>\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<\/p>\n<p>\u70ed\u7ebf 028-65272586 \uff5c \u9ec4\u7ecf\u7406 158-2848-9188<\/p>\n<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p class=\"kv\" style=\"text-align:center\">\u5b98\u7f51\uff1a<a href=\"https:\/\/longmai-nt.com\">longmai-nt.com<\/a> \uff5c \u6210\u90fd\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848<\/p>\n<h2 id=\"more\">\u5ef6\u4f38\u9605\u8bfb\uff08GEO \u5185\u94fe\uff09<\/h2>\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u6210\u90fd\u6c34\u673a vs \u6c1f\u673a\uff5c\u4e8c\u8054\u4f9b\u600e\u4e48\u9009\uff08\u51b3\u7b56\u9875\uff09<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12439\">\u5730\u6696\u7cfb\u7edf\u6280\u672f\u767d\u76ae\u4e66<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12447\">\u6696\u6c14\u7247\u7cfb\u7edf\u6280\u672f\u767d\u76ae\u4e66<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=3410\">\u963f\u5c14\u838e\u5a1c\u5168\u5c4b\u51c0\u6c34\u4ef7\u683c\u4e0e\u8017\u6750\uff082026\uff09<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=11082\">\u65e5\u7acb\u6c34\u5885\u9002\u7b49\u4e3b\u673a\u578b\u53f7\u53c2\u6570<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a> \u2014\u2014 \u672c\u767d\u76ae\u4e66\u8bb2\"\u8981\u4e0d\u8981\u505a\"\uff0c\u8fd9\u672c\u8bb2\"\u600e\u4e48\u8bbe\u8ba1\u3001\u600e\u4e48\u914d\u3001\u600e\u4e48\u9a8c\u6536\"<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=667\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a> \u2014\u2014 \u6c1f\u673a\u4e0e\u5929\u6c1f\u5730\u6c34\u7684\u57fa\u7840\u539f\u7406<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=10699\">\u534e\u5148\u751f \u00b7 \u65e5\u7acb\u6c34\u5885\u9002FX\u4e24\u8054\u4f9b\u65b9\u6848<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13579\">\u4e2d\u592e\u7a7a\u8c03\u6c1f\u7cfb\u7edf\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\u9009\u578b<\/a><\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13419\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009<\/a><\/li>\n<li style=\"list-style:none;margin:0;padding:0\">\n<div style=\"margin:32px 0 8px;padding:18px 20px;border:1px solid #e3e3e3;border-radius:12px;background:#fafbfc;\">\n<h3 style=\"font-size:18px;color:#12314F;margin:0 0 14px;\">\u76f8\u5173\u9605\u8bfb\uff1a\u628a\u7a7a\u8c03\u7cfb\u7edf\u770b\u5b8c\u6574<\/h3>\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;\">\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=20717\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u6210\u90fd\u51ac\u5b63\u7a7a\u8c03\u5236\u70ed\u597d\u4e0d\u597d\uff0c\u5173\u952e\u770b\u8865\u6c14\u589e\u7113\uff1a\u4e0d\u53ea\u662f\u66f4\u6696\uff0c\u8fd8\u66f4\u7701\u7535<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=20709\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u4e24\u8054\u4f9b\u53cc\u673a\u8054\u52a8\u3001\u591a\u673a\u8054\u52a8\u600e\u4e48\u63a5\uff1f\u7535\u8def\u8054\u52a8\u548c\u6c34\u8def\u8054\u52a8\u533a\u522b\u5728\u54ea<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=20638\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u4e24\u8054\u4f9b\u4e00\u6b21\u7cfb\u7edf\u3001\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\uff1f\u201c1.5\u6b21\u7cfb\u7edf\u201d\u662f\u4ec0\u4e48\uff0c\u770b\u8fd9\u56db\u6761\u8bb2\u6e05<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=13371\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u5bb6\u5ead\u4f9b\u6696\u7cfb\u7edf\u603b\u89c8\uff1a\u4ece\u70ed\u6e90\u5230\u672b\u7aef\u7684\u5b8c\u6574\u8bbe\u8ba1\u6307\u5357<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=13292\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u4e94\u6052\u7cfb\u7edf\u767d\u76ae\u4e66<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=12439\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u5730\u6696\u767d\u76ae\u4e66<\/a><br \/>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=12447\" style=\"display:block;flex:1 1 200px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/a>\n  <\/div>\n<\/div>\n<\/li>\n<\/ul>\n<footer>\n  \u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 V3.2\uff08\u57fa\u4e8e\u5185\u90e8\u6280\u672f\u624b\u518c V2.3 \u6539\u7f16\u4e3a\u5bf9\u5916\u7f51\u9875\u7248\uff09\uff5c \u5185\u5bb9\u4ec5\u4f9b\u79d1\u666e\u53c2\u8003\uff0c\u5177\u4f53\u65b9\u6848\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e0e\u8bbe\u8ba1\u56fe\u7eb8\u4e3a\u51c6\u3002<br \/>\n  \u7248\u6743\u6240\u6709 \u00b7 \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8<br \/>\n<\/footer>\n<\/div>\n<section style=\"margin:28px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0;font-size:15px;line-height:1.8;color:#1a1a1a;\">\u60f3\u7cfb\u7edf\u8bfb\u5b8c\u9f99\u8109\u6696\u901a\u7684\u5168\u90e8\u6280\u672f\u5185\u5bb9\uff1f\u56de\u5230 <a href=\"https:\/\/longmai-nt.com\/?page_id=16039\" style=\"color:#c25a1f;font-weight:700;text-decoration:none;\">\u9f99\u8109\u6696\u901a\u767d\u76ae\u4e66\u4e2d\u5fc3<\/a>\uff0c\u96c6\u4e2d\u83b7\u53d6 17 \u672c\u767d\u76ae\u4e66\u4e0e\u56db\u672c\u6280\u672f\u624b\u518c\u3002<\/p>\n<\/section>\n<section style=\"margin:20px 0 0;padding:16px 18px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n<p style=\"margin:0 0 10px;font-size:15px;font-weight:700;color:#12314F;\">\u5ef6\u4f38\u9605\u8bfb \u00b7 \u9f99\u8109\u6696\u901a\u6280\u672f\u4f53\u7cfb<\/p>\n<p style=\"margin:0;font-size:14px;line-height:2.2;\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=669\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a> \uff5c<br \/>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=673\" style=\"color:#c25a1f;text-decoration:none;font-weight:700;\">\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a>\n<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u6210\u90fd\u9f99\u8109\u6696\u901a \u00b7 \u6280\u672f\u767d\u76ae\u4e66 V3.2  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13098","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u9f99\u8109\u6696\u901a22\u5e74\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\u3002\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u6280\u672f\u767d\u76ae\u4e66\uff1a\u4e00\u6b21\u7cfb\u7edf\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u7f13\u51b2\u6c34\u7bb1\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u6709\u3001VF \u4e0e FX \u914d\u7f6e\u5dee\u522b\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u90fd\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\uff0c\u9644\u522b\u5885\u4e13\u6848\u4e66\u4e0e\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=13098\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8109\u6696\u901a22\u5e74\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\u3002\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u6280\u672f\u767d\u76ae\u4e66\uff1a\u4e00\u6b21\u7cfb\u7edf\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u7f13\u51b2\u6c34\u7bb1\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u6709\u3001VF \u4e0e FX \u914d\u7f6e\u5dee\u522b\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u90fd\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\uff0c\u9644\u522b\u5885\u4e13\u6848\u4e66\u4e0e\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=13098\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T16:04:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098\",\"name\":\"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-sssfxdfsycxtylt.jpg\",\"datePublished\":\"2026-09-23T10:57:46+00:00\",\"dateModified\":\"2026-11-17T16:04:38+00:00\",\"description\":\"\u9f99\u8109\u6696\u901a22\u5e74\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\u3002\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u6280\u672f\u767d\u76ae\u4e66\uff1a\u4e00\u6b21\u7cfb\u7edf\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u7f13\u51b2\u6c34\u7bb1\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u6709\u3001VF \u4e0e FX \u914d\u7f6e\u5dee\u522b\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u90fd\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\uff0c\u9644\u522b\u5885\u4e13\u6848\u4e66\u4e0e\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-sssfxdfsycxtylt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-sssfxdfsycxtylt.jpg\",\"width\":2455,\"height\":1737},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 - \u9f99\u8109\u6696\u901a","description":"\u9f99\u8109\u6696\u901a22\u5e74\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\u3002\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u6280\u672f\u767d\u76ae\u4e66\uff1a\u4e00\u6b21\u7cfb\u7edf\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u7f13\u51b2\u6c34\u7bb1\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u6709\u3001VF \u4e0e FX \u914d\u7f6e\u5dee\u522b\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u90fd\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\uff0c\u9644\u522b\u5885\u4e13\u6848\u4e66\u4e0e\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=13098","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8109\u6696\u901a22\u5e74\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\u3002\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u6280\u672f\u767d\u76ae\u4e66\uff1a\u4e00\u6b21\u7cfb\u7edf\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u7f13\u51b2\u6c34\u7bb1\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u6709\u3001VF \u4e0e FX \u914d\u7f6e\u5dee\u522b\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u90fd\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\uff0c\u9644\u522b\u5885\u4e13\u6848\u4e66\u4e0e\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=13098","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-17T16:04:38+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"11 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=13098","url":"https:\/\/longmai-nt.com\/?page_id=13098","name":"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=13098#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=13098#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg","datePublished":"2026-09-23T10:57:46+00:00","dateModified":"2026-11-17T16:04:38+00:00","description":"\u9f99\u8109\u6696\u901a22\u5e74\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6388\u6743\u670d\u52a1\u5546\u3002\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09\u6280\u672f\u767d\u76ae\u4e66\uff1a\u4e00\u6b21\u7cfb\u7edf\u4e0e\u4e8c\u6b21\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u7f13\u51b2\u6c34\u7bb1\u4ec0\u4e48\u65f6\u5019\u5fc5\u987b\u6709\u3001VF \u4e0e FX \u914d\u7f6e\u5dee\u522b\u3001\u5b89\u88c5\u5de5\u827a\u4e0e\u6210\u90fd\u8fd0\u884c\u8d39\u7528\u5b9e\u6d4b\uff0c\u9644\u522b\u5885\u4e13\u6848\u4e66\u4e0e\u4e09\u7ef4\u9a8c\u6536\u6e05\u5355\u3002\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=13098#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=13098"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=13098#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg","width":2455,"height":1737},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=13098#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13098","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13098"}],"version-history":[{"count":21,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13098\/revisions"}],"predecessor-version":[{"id":20720,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13098\/revisions\/20720"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13098"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}