{"id":13223,"date":"2026-09-27T13:07:24","date_gmt":"2026-09-27T05:07:24","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=13223"},"modified":"2026-10-14T11:33:13","modified_gmt":"2026-10-14T03:33:13","slug":"%e5%91%a8%e5%93%a5-%c2%b7-%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%ef%bc%88%e6%97%a5%e7%ab%8b%e8%88%92%e4%ba%ab%e5%8d%95%e9%a3%8e%e6%89%87-%c2%b7-125-140%ef%bc%89%e4%b8%89%e9%85%8d%e7%bd%ae%e6%8a%80","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=13223","title":{"rendered":"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4"},"content":{"rendered":"\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"\u5468\u54e5 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab125\u5355\u98ce\u6247\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4\",\n      \"author\": { \"@type\": \"Person\", \"name\": \"\u5f90\u65b0\u5e73\", \"jobTitle\": \"\u6696\u901a\u65b9\u6848\u987e\u95ee\", \"affiliation\": \"\u9f99\u8109\u6696\u901a\" },\n      \"publisher\": { \"@type\": \"Person\", \"name\": \"\u5f90\u65b0\u5e73\" },\n      \"datePublished\": \"2026-09-27\",\n      \"inLanguage\": \"zh-CN\",\n      \"about\": \"\u6210\u90fd\u4e09\u5ba4\u4e24\u5385\u5efa\u9762114\u33a1\/\u5957\u5185\u7ea690\u33a1\uff0c\u65e5\u7acb\u8212\u4eab125\u5355\u98ce\u6247 RAS-125HRNAQ \u914d\u5ba2\u9910\u5385 71 \/ 90 \/ 71+25 \u4e09\u79cd\u5185\u673a\u914d\u7f6e\u7684\u6280\u672f\u5bf9\u6bd4\u4e0e\u8fde\u63a5\u7387\u6821\u6838\uff0c\u7eaf\u6280\u672f\u53c2\u8003\u4e0d\u542b\u62a5\u4ef7\"\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        { \"@type\": \"Question\", \"name\": \"\u4e09\u79cd\u914d\u7f6e\u7684\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u53ea\u5728\u5ba2\u9910\u5385\u3002\u5916\u673a\uff08\u8212\u4eab125\u5355\u98ce\u6247\uff09\u3001\u4e3b\u536736\u3001\u5367\u5ba4B 22\u3001\u5367\u5ba4C 18 \u4e09\u79cd\u5b8c\u5168\u4e00\u81f4\u3002\u5dee\u522b\u662f\u5ba2\u9910\u5385\u653e 71\uff08A\uff09\u300190\uff08B\uff09\u8fd8\u662f 71+25\uff08C\uff09\uff0c\u7531\u6b64\u5e26\u6765\u5185\u673a\u603b\u5bb9\u91cf 14.7 \/ 16.6 \/ 17.2 kW\uff0c\u4ee5\u53ca\u8fde\u63a5\u7387 117.6% \/ 118.6% \/ 122.9% \u7684\u4e0d\u540c\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"\u8fde\u63a5\u7387 B\u3001C \u90fd\u8d85\u4e86 130%\uff0c\u662f\u4e0d\u662f\u4e0d\u80fd\u7528\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e0d\u662f\u4e0d\u80fd\u7528\uff0c\u800c\u662f\u4e0d\u5b9c\u8fd9\u6837\u4ea4\u4ed8\u3002\u65e5\u5e38\u591a\u6570\u65f6\u95f4\u4e0d\u4f1a\u6240\u6709\u5185\u673a\u540c\u65f6\u6ee1\u8d1f\u8377\u5168\u5f00\uff0c\u5b9e\u9645\u5f71\u54cd\u6709\u9650\uff1b\u4f46\u5168\u5f00\u65f6\u5916\u673a\u80fd\u529b\u4f1a\u88ab\u644a\u8584\u3001\u6bcf\u53f0\u5185\u673a\u51fa\u529b\u6253\u6298\u3002\u6309\u6c1f\u7cfb\u7edf\u89c4\u8303 50%\u2013130%\uff0cB\uff08132.8%\uff09\u3001C\uff08137.6%\uff09\u90fd\u9700\u8981\u5904\u7406\u3002\u89e3\u51b3\u529e\u6cd5\u662f\u5916\u673a\u5347 140 \u5355\u98ce\u6247\u2014\u2014\u5c3a\u5bf8\u4e0e 125 \u5b8c\u5168\u76f8\u540c\uff0c\u5347\u7ea7\u540e B \u964d\u5230 118.6%\u3001C \u964d\u5230 122.9%\uff0c\u56de\u5230\u89c4\u8303\u5185\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"125 \u548c 140 \u5355\u98ce\u6247\u5c3a\u5bf8\u771f\u7684\u4e00\u6837\u5417\uff1f\u6362\u4e86\u4f1a\u4e0d\u4f1a\u653e\u4e0d\u4e0b\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5b8c\u5168\u4e00\u6837\uff0c\u90fd\u662f 770\u00d7980\u00d7360mm\u3002\u8fd9\u662f\u672c\u6b21\u65b9\u6848\u6700\u5173\u952e\u7684\u4e00\u6761\uff1a\u60a8\u62c5\u5fc3\u673a\u4f4d\u653e\u4e0d\u4e0b\u624d\u6307\u5b9a\u5355\u98ce\u6247\uff0c\u800c\u5347\u5230 140 \u5e76\u4e0d\u9700\u8981\u591a\u5360\u4e00\u5bf8\u673a\u4f4d\uff0c\u566a\u97f3\u4e5f\u540c\u4e3a 54dB(A)\u3002\u5dee\u522b\u53ea\u6709\u5236\u51b7\u80fd\u529b\u4ece 12.5kW \u63d0\u5230 14.0kW\u3001APF \u7531 5.90 \u5fae\u964d\u5230 5.80\u3001\u51c0\u91cd\u7531 64kg \u5230 71kg\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"\u5ba2\u9910\u5385 41.6\u33a1\uff0c\u5b98\u65b9\u9009\u578b\u53e3\u5f84 35\u201350\u33a1 \u6863\u4e3a\u4ec0\u4e48\u8bf4 63\/71 \u578b\u5c31\u591f\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u6309\u9f99\u8109\u5b98\u7f51\u8212\u4eab\u9009\u578b\u53e3\u5f84\uff1a25\u201335\u33a1\uff08\u5927\u5ba2\u5385\uff09\u5bf9\u5e94 63\/71\uff0c35\u201350\u33a1\uff08\u5927\u5ba2\u5385\/\u9910\u5ba2\u4e00\u4f53\uff09\u540c\u6837\u843d\u5728 63\/71 \u6863\u5373\u53ef\u3002\u60a8\u5bb6\u5ba2\u9910\u5385 41.6\u33a1 \u6309 150W\/\u33a1 \u5355\u5236\u51b7\u7b97\u7ea6 6.24kW\uff0c63 \u578b\u540d\u4e49 6.3kW \u521a\u597d\u8986\u76d6\u2014\u2014\u6240\u4ee5\u914d\u7f6e A \u7684 63 \u578b\u4ee5\u5355\u5236\u51b7\u5b9a\u4f4d\uff0c\u5bf9\u672c\u6237\u5ba2\u9910\u5385\u5236\u51b7\u5b8c\u5168\u591f\u7528\uff0c\u4e5f\u662f\u5b98\u65b9\u53e3\u5f84\u8ba4\u53ef\u7684\u914d\u7f6e\u3002B\/C \u628a\u5ba2\u9910\u5385\u5185\u673a\u505a\u5927\uff0871+25 \/ 90\uff09\uff0c\u4e3b\u8981\u662f\u8fdb\u4e00\u6b65\u517c\u987e\u5236\u70ed\u3001\u5206\u533a\u6c14\u6d41\u4e0e\u5236\u51b7\u4f59\u91cf\uff1b\u771f\u6b63\u8ba9 A \u4e0d\u5982 B\/C \u7684\uff0c\u662f\u5236\u70ed\u2014\u201463 \u578b\u4ee5\u5236\u51b7\u4e3a\u4e3b\uff0c\u51ac\u5929\u5ba2\u9910\u5385\u5236\u70ed\u4e0d\u7406\u60f3\uff0c\u4e3b\u8981\u9760\u5367\u5ba4\u7a7a\u8c03\u8865\u4f4d\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"90 \u578b\u5185\u673a\u548c 63\/71 \u578b\uff0c\u540a\u9876\u4e0a\u5dee\u591a\u5c11\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"63\/71 \u578b\u662f 192\u00d71180\u00d7447mm\uff08\u9ad8\u00d7\u5bbd\u00d7\u6df1\uff09\uff0c90 \u578b\u662f 218\u00d7(1480+82)\u00d7615mm\u2014\u2014\u9ad8 26mm\u3001\u5bbd\u7ea6 380mm\u3001\u8fdb\u6df1\u591a 168mm\u3002\u4e5f\u5c31\u662f\u8bf4\u7528 90 \u578b\uff0c\u5ba2\u9910\u5385\u540a\u9876\u8981\u6bd4\u7528 63\/71 \u578b\u591a\u7559 168mm \u8fdb\u6df1\u3002\u8ffd\u6c42\u7f8e\u89c2\u3001\u4e0d\u60f3\u538b\u5c42\u9ad8\u7684\u8bdd\uff0c\u8fd9\u4e00\u70b9\u5fc5\u987b\u63d0\u524d\u548c\u6728\u5de5\u4ea4\u5e95\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"\u53ea\u505a\u7a7a\u8c03\u4e0d\u505a\u5730\u6696\uff0c\u51ac\u5929\u5367\u5ba4\u9760\u7a7a\u8c03\u5236\u70ed\u591f\u5417\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e09\u4e2a\u5367\u5ba4\u662f\u6309\u5236\u70ed 220W\/\u33a1 \u53e3\u5f84\u9009\u7684\u673a\uff0c\u4e0d\u662f\u53ea\u6309\u5236\u51b7\u9009\uff1a\u4e3b\u5367 15.4\u33a1 \u9700 3.39kW\uff0c\u914d 36 \u578b\u5236\u70ed 4.0kW\uff1b\u5367\u5ba4B \u9700 2.29kW\uff0c\u914d 22 \u578b\u5236\u70ed 2.5kW\uff1b\u5367\u5ba4C \u9700 1.85kW\uff0c\u914d 18 \u578b\u5236\u70ed 2.2kW\uff0c\u4e09\u95f4\u90fd\u6709\u4f59\u91cf\u3002\u9700\u8981\u8bf4\u660e\u7684\u662f\u7a7a\u8c03\u5236\u70ed\u662f\u70ed\u98ce\u81ea\u4e0a\u800c\u4e0b\uff0c\u811a\u611f\u4e0d\u5982\u5730\u6696\uff1b\u6210\u90fd\u51ac\u5b63\u6c14\u6e29\u4e0d\u7b97\u6781\u7aef\uff0c\u4e24\u53e3\u5b50\u5e38\u4f4f\u8db3\u591f\uff0c\u4f46\u5982\u7279\u522b\u5728\u610f\u811a\u6696\u53ef\u540e\u671f\u518d\u8bc4\u4f30\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"\u600e\u4e48\u4fdd\u8bc1\u8f85\u6750\u4e0d\u88ab\u5077\u5de5\u51cf\u6599\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e09\u4ef6\u4e8b\u73b0\u573a\u53ef\u6838\u9a8c\uff1a\u2460 \u710a\u63a5\u6709\u6ca1\u6709\u5145\u6c2e\u2014\u2014\u770b\u73b0\u573a\u5e26\u6ca1\u5e26\u6c2e\u6c14\u74f6\uff0c\u710a\u53e3\u53d1\u9ed1\u5c31\u662f\u6ca1\u5145\uff1b\u2461 \u4fdd\u538b\u8bb0\u5f55\u2014\u20144.0MPa \u7a33\u538b 24 \u5c0f\u65f6\u4ee5\u4e0a\u7684\u7167\u7247\u6216\u8bb0\u5f55\u5fc5\u987b\u7ed9\u5230\u60a8\uff1b\u2462 \u4fdd\u6e29\u539a\u5ea6\u2014\u2014\u94dc\u7ba1\u6a61\u5851\u4fdd\u6e29\u4e0d\u5c0f\u4e8e 15mm\uff0c\u62ff\u5361\u5c3a\u91cf\uff0c\u63a5\u5934\u4e0d\u80fd\u9732\u94dc\u3002\u65b9\u6848\u4e66\u5df2\u628a\u5168\u90e8\u8f85\u6750\u7684\u54c1\u724c\u89c4\u683c\u5199\u660e\uff0c\u8fdb\u573a\u540e\u9010\u9879\u5bf9\u7167\u5373\u53ef\u3002\" } },\n        { \"@type\": \"Question\", \"name\": \"\u8fd9\u4e2a\u65b9\u6848\u4e66\u4e3a\u4ec0\u4e48\u6ca1\u6709\u62a5\u4ef7\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u672c\u9875\u5b9a\u4f4d\u662f\u6280\u672f\u6807\uff0c\u4e0d\u662f\u4ef7\u683c\u6807\u2014\u2014\u76ee\u7684\u662f\u8ba9\u60a8\u805a\u7126\u54ea\u79cd\u914d\u7f6e\u66f4\u9002\u914d\u6211\u5bb6\uff0c\u800c\u4e0d\u662f\u505a\u4e00\u6b21\u6027\u5c01\u6807\u6bd4\u4ef7\u3002\u5916\u9762\u7684\u4f4e\u4ef7\u62a5\u4ef7\u5e38\u5e38\u5148\u538b\u4ef7\u3001\u518d\u9760\u8f85\u6750\u964d\u6807\u6216\u589e\u9879\u627e\u8865\u3002\u914d\u7f6e\u3001\u53c2\u6570\u3001\u6750\u6599\u6e05\u5355\u90fd\u662f\u53ef\u6838\u9a8c\u7684\u786c\u5185\u5bb9\uff1b\u4ef7\u683c\u4e0e\u5f53\u671f\u6d3b\u52a8\u4f18\u60e0\u3001\u5382\u5bb6\u8865\u8d34\u9700\u5728\u7ebf\u4e0b\u6c9f\u901a\u65f6\u9010\u9879\u786e\u8ba4\u3002\" } }\n      ]\n    }\n  ]\n}\n<\/script>\n<style>\n\n.lm-wrap{\n  --lm-primary:#1a3a6e; --lm-primary-soft:#eaf0f8; --lm-accent:#e8852b; --lm-accent-soft:#fdf0e3; --lm-success:#2e8b6f; --lm-success-soft:#e6f3ee; --lm-danger:#c0392b; --lm-danger-soft:#fbe9e7; --lm-bg:#ffffff; --lm-bg-soft:#f6f8fb; --lm-text:#1f2733; --lm-text-2:#5a6675; --lm-border:#e2e8f0; --lm-radius:14px; --lm-shadow:0 6px 22px rgba(26,58,110,.08);\nmax-width:960px;margin:0 auto;padding:0 18px 60px;font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:var(--lm-text);line-height:1.7;}\n.lm-wrap *{box-sizing:border-box;}\n.lm-hero{position:relative;background-color:#1a3a6e;background-image:linear-gradient(135deg,rgba(26,58,110,.56),rgba(42,90,158,.30));background-position:center;background-size:cover;background-repeat:no-repeat;color:#fff;border-radius:0 0 22px 22px;padding:46px 32px 36px;text-shadow:0 1px 6px rgba(0,0,0,.45);}\n.lm-hero h2{font-size:24px;margin:0 0 8px;font-weight:800;letter-spacing:.5px;}\n.lm-hero .lm-sub{opacity:.9;font-size:15.5px;}\n.lm-hero .lm-kpis{display:flex;gap:14px;flex-wrap:wrap;margin-top:22px;}\n.lm-hero .lm-kpi{background:rgba(255,255,255,.16);border:1px solid rgba(255,255,255,.28);border-radius:12px;padding:14px 18px;flex:1 1 130px;min-width:118px;}\n.lm-hero .lm-kpi b{font-size:21px;display:block;}\n.lm-hero .lm-kpi span{font-size:12px;opacity:.82;}\n\n.lm-steps{position:sticky;top:0;z-index:30;display:flex;gap:6px;flex-wrap:nowrap;overflow-x:auto;-webkit-overflow-scrolling:touch;justify-content:center;background:var(--lm-primary);border-radius:12px;box-shadow:var(--lm-shadow);margin:14px 0 4px;padding:6px;}\n.lm-steps a{flex:0 0 auto;min-width:auto;display:flex;flex-direction:column;align-items:center;gap:2px;color:#fff;text-decoration:none;font-size:12.5px;font-weight:600;padding:9px 14px;border-radius:8px;}\n.lm-steps a:last-child{border-right:none;}\n.lm-steps a:hover{background:rgba(255,255,255,.12);}\n.lm-steps .lm-step-no{font-size:17px;font-weight:800;color:var(--lm-accent);}\n\n.lm-toc{display:flex;gap:6px;flex-wrap:wrap;justify-content:center;padding:12px 0 6px;border-bottom:1px solid var(--lm-border);margin:16px 0 4px;}\n.lm-toc a{color:var(--lm-primary);text-decoration:none;font-size:12.5px;padding:5px 12px;border-radius:20px;background:var(--lm-bg-soft);border:1px solid var(--lm-border);}\n.lm-toc a:hover{background:var(--lm-accent-soft);color:var(--lm-accent);}\n.lm-toc .lm-toc-ov{font-weight:700;background:var(--lm-primary-soft);}\n\n.lm-footnav{display:flex;gap:10px;flex-wrap:wrap;font-size:12.5px;margin-top:18px;padding-top:12px;border-top:1px dashed var(--lm-border);}\n.lm-footnav a{color:var(--lm-primary);text-decoration:none;}\n.lm-footnav a:hover{color:var(--lm-accent);}\n\n.lm-sec{margin:26px 0;}\n.lm-sec h2{font-size:21px;color:var(--lm-primary);border-left:5px solid var(--lm-accent);padding-left:12px;margin:0 0 6px;}\n.lm-sec h3{font-size:16.5px;color:var(--lm-primary);margin:20px 0 8px;}\n.lm-sec h4{font-size:15px;color:var(--lm-primary);margin:14px 0 6px;}\n.lm-lead{color:var(--lm-text-2);font-size:14px;margin:0 0 12px;}\n\n.lm-xgeo{background:var(--lm-bg-soft);border:1px solid var(--lm-border);border-radius:var(--lm-radius);padding:16px 18px;margin-top:16px;box-shadow:var(--lm-shadow);}\n.lm-xgeo h3{margin:0 0 10px;font-size:15px;display:flex;align-items:center;gap:6px;}\n.lm-xgeo-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:10px 18px;}\n.lm-xgeo-grid div{font-size:13px;}\n.lm-xgeo-grid b{color:var(--lm-primary);display:block;font-size:11.5px;margin-bottom:2px;opacity:.8;}\n\n.lm-card{background:var(--lm-bg);border:1px solid var(--lm-border);border-radius:var(--lm-radius);padding:18px;box-shadow:var(--lm-shadow);}\n.lm-grid3{display:grid;grid-template-columns:repeat(3,1fr);gap:18px;}\n.lm-grid2{display:grid;grid-template-columns:repeat(2,1fr);gap:16px;}\n.lm-tag{display:inline-block;font-size:12px;font-weight:700;padding:3px 10px;border-radius:20px;margin:3px 4px 3px 0;}\n.lm-tag-b{background:var(--lm-primary-soft);color:var(--lm-primary);}\n.lm-tag-o{background:var(--lm-accent-soft);color:var(--lm-accent);}\n.lm-tag-g{background:var(--lm-success-soft);color:var(--lm-success);}\n.lm-tag-r{background:var(--lm-danger-soft);color:var(--lm-danger);}\n.lm-tbd{color:var(--lm-accent);font-weight:800;border-bottom:2px dashed var(--lm-accent);}\n\n.lm-flip{background:transparent;perspective:1400px;}\n.lm-flip-input{position:absolute;opacity:0;pointer-events:none;}\n.lm-flip-card{display:block;cursor:pointer;min-height:300px;}\n.lm-flip-inner{display:grid;width:100%;min-height:300px;transition:transform .6s;transform-style:preserve-3d;}\n.lm-flip-input:checked + .lm-flip-card .lm-flip-inner{transform:rotateY(180deg);}\n.lm-flip-front,.lm-flip-back{grid-area:1\/1;backface-visibility:hidden;-webkit-backface-visibility:hidden;border-radius:var(--lm-radius);border:1px solid var(--lm-border);box-shadow:var(--lm-shadow);padding:18px 18px 22px;background:var(--lm-bg);overflow:hidden;}\n.lm-flip-back{transform:rotateY(180deg);background:var(--lm-bg-soft);}\n.lm-flip-front h4,.lm-flip-back h4{margin:0 0 8px;font-size:16px;color:var(--lm-primary);}\n.lm-flip-front p,.lm-flip-back p,.lm-flip-back li{font-size:13.5px;color:var(--lm-text-2);}\n.lm-flip-front .lm-big{font-size:18px;font-weight:800;color:var(--lm-primary);margin:2px 0 8px;}\n.lm-flip-back ul{margin:6px 0 0;padding-left:18px;}\n.lm-flip-hint{text-align:center;font-size:11px;color:var(--lm-text-2);margin-top:6px;}\n\n.lm-table{width:100%;border-collapse:collapse;font-size:13.5px;margin-top:10px;overflow:hidden;border-radius:10px;}\n.lm-scroll{overflow-x:auto;-webkit-overflow-scrolling:touch;margin-top:10px;}\n.lm-table th,.lm-table td{border:1px solid var(--lm-border);padding:10px 12px;vertical-align:top;text-align:left;}\n.lm-table thead th{background:var(--lm-primary);color:#fff;font-weight:700;}\n.lm-table tbody th{background:var(--lm-bg-soft);color:var(--lm-primary);font-weight:700;width:158px;}\n.lm-table .lm-col-a{background:var(--lm-primary-soft);}\n.lm-table .lm-col-c{background:var(--lm-success-soft);}\n.lm-table thead th.lm-col-a{background:var(--lm-primary);color:#fff;}\n.lm-table thead th.lm-col-c{background:var(--lm-success);color:#fff;}\n\n.lm-diag th:nth-child(1){width:26%;}\n.lm-diag th:nth-child(2){width:18%;}\n.lm-diag th:nth-child(3){width:24%;}\n.lm-diag th:nth-child(4){width:32%;}\n\n.lm-toggle{position:relative;margin-top:8px;}\n.lm-toggle-input{position:absolute;opacity:0;pointer-events:none;}\n.lm-toggle-tabs{display:flex;gap:8px;flex-wrap:wrap;margin:10px 0 14px;}\n.lm-toggle-tab{cursor:pointer;padding:8px 16px;border-radius:22px;background:var(--lm-bg-soft);border:1px solid var(--lm-border);font-size:13.5px;font-weight:700;color:var(--lm-primary);}\n.lm-toggle-tab:hover{background:var(--lm-accent-soft);}\n.lm-toggle-panel{display:none;}\n#lm-sA:checked ~ .lm-toggle-tabs label[for=\"lm-sA\"],\n#lm-sB:checked ~ .lm-toggle-tabs label[for=\"lm-sB\"],\n#lm-sC:checked ~ .lm-toggle-tabs label[for=\"lm-sC\"]{background:var(--lm-primary);color:#fff;border-color:var(--lm-primary);}\n#lm-sA:checked ~ .lm-panel-a,\n#lm-sB:checked ~ .lm-panel-b,\n#lm-sC:checked ~ .lm-panel-c{display:block;}\n\n.lm-vs{display:grid;grid-template-columns:1fr 1fr;gap:18px;margin-top:14px;}\n.lm-vs .lm-card h4{margin:0 0 10px;font-size:17px;color:var(--lm-primary);}\n.lm-vs .lm-card ul{margin:6px 0 0;padding-left:18px;}\n.lm-vs .lm-card li{margin:7px 0;font-size:13.5px;color:var(--lm-text-2);}\n.lm-vs .lm-pro{border-top:4px solid var(--lm-success);}\n.lm-vs .lm-con{border-top:4px solid var(--lm-accent);}\n\n.lm-score td{text-align:center;font-weight:700;}\n.lm-score .lm-star{color:var(--lm-accent);}\n\n.lm-links{display:grid;grid-template-columns:repeat(2,1fr);gap:14px;}\n.lm-link{display:block;text-decoration:none;color:var(--lm-text);background:var(--lm-bg);border:1px solid var(--lm-border);border-radius:12px;padding:14px 16px;box-shadow:var(--lm-shadow);transition:all .15s;}\n.lm-link:hover{border-color:var(--lm-accent);background:var(--lm-accent-soft);}\n.lm-link b{color:var(--lm-primary);font-size:15px;display:block;margin-bottom:4px;}\n.lm-link span{font-size:13px;color:var(--lm-text-2);}\n\n.lm-stages{display:grid;grid-template-columns:repeat(2,1fr);gap:14px;margin-top:12px;}\n.lm-stage{display:flex;gap:12px;align-items:flex-start;background:var(--lm-bg);border:1px solid var(--lm-border);border-radius:12px;padding:14px;box-shadow:var(--lm-shadow);}\n.lm-stage .lm-no{flex:0 0 34px;height:34px;border-radius:50%;background:var(--lm-primary);color:#fff;display:flex;align-items:center;justify-content:center;font-weight:800;font-size:15px;}\n.lm-stage b{display:block;color:var(--lm-primary);font-size:14px;margin-bottom:2px;}\n.lm-stage p{margin:0;font-size:12.5px;color:var(--lm-text-2);}\n\n.lm-verify{list-style:none;padding:0;margin:12px 0 0;display:grid;grid-template-columns:repeat(2,1fr);gap:10px;}\n.lm-verify li{background:var(--lm-success-soft);border:1px solid #bfe3d6;border-radius:10px;padding:10px 14px;font-size:13px;color:#1f513f;}\n.lm-verify li b{color:var(--lm-success);}\n\n.lm-cta{background:linear-gradient(135deg,#1a3a6e,#2a5a9e);color:#fff;border-radius:18px;padding:26px;margin-top:24px;}\n.lm-cta h3{color:#fff;margin:0 0 12px;}\n.lm-cta .lm-phones{font-size:20px;font-weight:800;letter-spacing:.5px;}\n.lm-cta a{color:#fff;}\n.lm-stores{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin-top:16px;}\n.lm-store{background:rgba(255,255,255,.1);border-radius:12px;padding:12px;text-align:center;}\n.lm-store .lm-photo{height:96px;border-radius:8px;background:rgba(255,255,255,.16);display:flex;align-items:center;justify-content:center;font-size:12px;color:#fff;margin-bottom:8px;overflow:hidden;}\n.lm-store .lm-photo img{width:100%;height:96px;object-fit:cover;border-radius:8px;display:block;}\n.lm-store b{font-size:14px;display:block;}\n.lm-store a{font-size:13px;text-decoration:underline;}\n.lm-btn{display:inline-block;background:var(--lm-accent);color:#fff;font-weight:700;padding:11px 22px;border-radius:10px;text-decoration:none;margin-top:14px;}\n.lm-note{font-size:12.5px;color:var(--lm-text-2);background:var(--lm-accent-soft);border-left:4px solid var(--lm-accent);padding:10px 14px;border-radius:8px;margin:12px 0;}\n.lm-promise{display:flex;flex-wrap:wrap;gap:10px 18px;margin:14px 0 6px;font-size:13.5px;color:#fff;}\n.lm-promise span{background:rgba(255,255,255,.12);border-radius:8px;padding:6px 12px;}\n.lm-svc{margin-top:12px;font-size:14px;color:#fff;}\n.lm-svc a{color:#fff;text-decoration:underline;}\n.lm-foot{text-align:center;font-size:12px;color:var(--lm-text-2);margin-top:30px;}\n\n.lm-certs{display:grid;grid-template-columns:repeat(5,1fr);gap:10px;margin:14px auto 0;max-width:860px;}\n.lm-cert{background:var(--lm-bg);border:1px solid var(--lm-border);border-radius:10px;overflow:hidden;box-shadow:var(--lm-shadow);}\n.lm-cert img{width:100%;height:88px;object-fit:contain;display:block;background:#fff;}\n\n.lm-gallery{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;margin-top:14px;}\n.lm-gallery .lm-shot{margin:0;background:var(--lm-bg);border:1px solid var(--lm-border);border-radius:10px;overflow:hidden;}\n.lm-gallery .lm-shot img{width:100%;height:150px;object-fit:cover;display:block;}\n.lm-gallery .lm-shot figcaption{font-size:11px;padding:6px 8px;color:var(--lm-text-2);text-align:center;}\n\n@media (max-width:739px){\n  .lm-grid3,.lm-weak,.lm-links,.lm-stages,.lm-gallery,.lm-xgeo-grid{grid-template-columns:1fr;}\n  .lm-grid2,.lm-vs,.lm-certs{grid-template-columns:1fr;}\n  .lm-verify{grid-template-columns:1fr;}\n  .lm-table{font-size:12px;}\n  .lm-hero h2{font-size:20px;}\n}\n.lm-prod{display:flex;gap:16px;align-items:center;margin:12px 0 16px;padding:14px 16px;border:1px solid var(--lm-border);border-radius:12px;background:var(--lm-bg-soft);text-decoration:none;transition:border-color .2s,box-shadow .2s;}\n.lm-prod:hover{border-color:var(--lm-accent);box-shadow:0 6px 18px rgba(26,58,110,.10);}\n.lm-prod img{width:200px;height:auto;flex:0 0 200px;border-radius:8px;background:#fff;display:block;}\n.lm-prod-b{display:block;}\n.lm-prod-t{display:block;font-size:15px;font-weight:700;color:var(--lm-primary);margin-bottom:6px;}\n.lm-prod-d{display:block;font-size:12.5px;color:var(--lm-text-2);line-height:1.75;}\n.lm-prod-more{display:inline-block;margin-top:8px;font-size:12.5px;font-weight:600;color:var(--lm-accent);}\n@media(max-width:600px){.lm-prod{flex-direction:column;align-items:flex-start;}.lm-prod img{width:100%;flex:none;}}\n\n\/* ===== \u5468\u54e5\u65b9\u6848\u4e66\u65b0\u589e ===== *\/\n.lm-warn-line{background:#fff3cd;border-left:4px solid var(--lm-accent);padding:14px 20px;border-radius:var(--lm-radius);margin:16px 0;font-size:14px;color:#856404;}\n.lm-warn-line strong{color:#533f03;}\n.lm-ok-line{background:#d4edda;border-left:4px solid var(--lm-success);padding:14px 20px;border-radius:var(--lm-radius);margin:16px 0;font-size:14px;color:#155724;}\n.lm-ok-line strong{color:#0b3618;}\n.lm-intlink{color:var(--lm-primary);text-decoration:underline;text-decoration-color:var(--lm-accent);text-underline-offset:2px;font-weight:500;}\n.lm-sm{font-size:12px;color:#6b7280;font-weight:400;display:inline-block;margin-top:2px;}\n\/* \u7ffb\u8f6c\u5361\u5185\u7684\u4ea7\u54c1\u5b9e\u666f\u56fe\uff1a\u6574\u56fe\u53ef\u89c1 + \u7f29\u5c0f\u5c45\u4e2d *\/\n.lm-sx-img{object-fit:contain;width:auto;max-width:86%;max-height:170px;margin:8px auto;display:block;background:#eef2f8;border-radius:8px;}\n\/* \u76d1\u7406\u9a8c\u6536 \/ \u65bd\u5de5\u793a\u4f8b\u56fe\uff1a\u6574\u56fe\u53ef\u89c1\u3001\u4e0d\u88c1\u5207\uff08\u8986\u76d6\u6a21\u677f cover\uff09 *\/\n.lm-gallery .lm-shot img{width:100%;height:220px;object-fit:contain;display:block;background:#eef2f8;}\n\/* ===== \u82f1\u96c4\u680f\uff1a\u8212\u4eab\u7cfb\u5217\u5b9e\u666f\u56fe + \u84dd\u8272\u6e10\u53d8\u4fdd\u8bc1\u6587\u5b57\u53ef\u8bfb ===== *\/\n.lm-hero{\n  background:linear-gradient(135deg, rgba(22,48,92,.50), rgba(42,90,158,.30)), url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p01-03.jpeg');\n  background-size:cover;\n  background-position:center;\n  background-repeat:no-repeat;\n}\n<\/style>\n\n<div class=\"lm-wrap\">\n\n  \n  <header class=\"lm-hero\">\n    <h1>\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4<\/h1>\n    <div class=\"lm-sub\">\u6210\u90fd \u00b7 \u5efa\u9762 114\u33a1 \/ \u5957\u5185\u7ea6 90\u33a1 \u00b7 \u4e09\u5ba4\u4e24\u5385\uff084 \u697c\u00b7\u4e2d\u5c42\u975e\u9876\u697c\uff09\u00b7 \u5e38\u4f4f 2 \u4eba \u00b7 \u53ea\u505a\u4e2d\u592e\u7a7a\u8c03\u4e0d\u505a\u5730\u6696 \u00b7 \u65e5\u7acb\u6210\u90fd\u76f4\u8425\u6388\u6743\u7ecf\u9500\u5546\u300c\u9f99\u8109\u6696\u901a\u300d\u00b7 \u7eaf\u6280\u672f\u53c2\u8003\u65b9\u6848\uff08\u4e0d\u542b\u62a5\u4ef7\uff09<\/div>\n    <div class=\"lm-kpis\">\n      <div class=\"lm-kpi\"><b>\u5468\u54e5<\/b><span>\u5ba2\u6237 \u00b7 \u4e24\u53e3\u5b50\u5e38\u4f4f 2 \u4eba<\/span><\/div>\n      <div class=\"lm-kpi\"><b>41.6\u33a1<\/b><span>\u5ba2\u9910\u5385\uff08\u4e0e\u9633\u53f0\u8fde\u901a\u00b7\u65e0\u95e8\uff09<\/span><\/div>\n      <div class=\"lm-kpi\"><b>\u8212\u4eab\u5355\u98ce\u6247 125\/140<\/b><span>\u5916\u673a RAS-125HRNAQ \/ RAS-140HRNAQ\uff08\u540c\u5c3a\u5bf8\uff09<\/span><\/div>\n      <div class=\"lm-kpi\"><b>3 \u79cd<\/b><span>\u5ba2\u9910\u5385\u5185\u673a\u914d\u7f6e\uff08A\/B\/C\uff09<\/span><\/div>\n      <div class=\"lm-kpi\"><b>770mm<\/b><span>\u5916\u673a\u9ad8\u5ea6 \u00b7 \u673a\u4f4d\u66f4\u53cb\u597d<\/span><\/div>\n    <\/div>\n  <\/header>\n\n  <nav class=\"lm-steps\">\n    <a href=\"#s1\"><span class=\"lm-step-no\">\u2460<\/span>\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/a>\n    <a href=\"#s1-need\"><span class=\"lm-step-no\">\u2461<\/span>\u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/a>\n    <a href=\"#s3\"><span class=\"lm-step-no\">\u2462<\/span>\u89e3\u51b3\u65b9\u6848<\/a>\n    <a href=\"#s6\"><span class=\"lm-step-no\">\u2463<\/span>\u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/a>\n    <a href=\"#s7\"><span class=\"lm-step-no\">\u2464<\/span>\u6848\u4f8b\u8fed\u4ee3\u9a8c\u8bc1<\/a>\n  <\/nav>\n\n  <div class=\"lm-xgeo\">\n    <h3>\ud83d\udcc7 XGEO \u6848\u4f8b\u4fe1\u606f\u5361<\/h3>\n    <div class=\"lm-xgeo-grid\">\n      <div><b>\u57ce\u5e02<\/b>\u6210\u90fd\uff08\u56db\u5ddd\uff09\u00b7 \u5c0f\u533a\u5f85\u8865<\/div>\n      <div><b>\u6237\u578b<\/b>\u4e09\u5ba4\u4e24\u5385 \u00b7 4 \u697c\u4e2d\u5c42\u975e\u9876\u697c \u00b7 \u5efa\u9762 114\u33a1 \/ \u5957\u5185\u7ea6 90\u33a1<\/div>\n      <div><b>\u5e38\u4f4f\u4eba\u53e3<\/b>2 \u4eba\uff08\u4e24\u53e3\u5b50\uff09<\/div>\n      <div><b>\u7a7a\u8c03\u4e3b\u673a<\/b>\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247\uff1a\u914d\u7f6e A=125\uff08RAS-125HRNAQ\uff09\u3001\u914d\u7f6e B\/C=140\uff08RAS-140HRNAQ\uff09\uff0c\u5747\u4e3a 770\u00d7980\u00d7360mm<\/div>\n      <div><b>\u7a7a\u8c03\u5185\u673a<\/b>\u4e09\u914d\u7f6e\u5185\u673a\uff1aA \u5ba2\u9910\u5385 RPIZ-71FSNAQD\/P\uff5cB \u5ba2\u9910\u5385 RPIZ-90FSNAQD\/P\uff5cC \u5ba2\u9910\u5385 RPIZ-71FSNAQD\/P + RPIZ-25FSNAQD\/P\uff1b\u4e3b\u5367 RPIZ-36FSNAQD\/P \/ \u5367\u5ba4B RPIZ-22FSNAQD\/P \/ \u5367\u5ba4C RPIZ-18FSNAQD\/P\uff08\u4e09\u79cd\u4e00\u81f4\uff09<\/div>\n      <div><b>\u5730\u6696<\/b>\u672c\u671f\u4e0d\u505a<\/div>\n      <div><b>\u63a7\u5236<\/b>\u6bcf\u53f0\u5185\u673a\u72ec\u7acb Wi-Fi \u578b\u7ebf\u63a7\u5668\uff08PC-P1HVQA\uff0c\u5168\u7cfb\u901a\u7528\uff09<\/div>\n    <\/div>\n  <\/div>\n\n  \n  <section class=\"lm-sec\" id=\"s1\">\n    <h2>\u2460 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2>\n    <div class=\"lm-toc\">\n      <a class=\"lm-toc-ov\" href=\"#s1\">\u25b8 \u672c\u8282\u603b\u89c8<\/a>\n      <a href=\"#s1-info\">\ud83d\udccb \u5ba2\u6237\u4fe1\u606f\u5361<\/a>\n      <a href=\"#s1-need\">\ud83d\udd0d \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/a>\n    <\/div>\n\n    <h3 id=\"s1-info\">1.1 \u5ba2\u6237\u4fe1\u606f\u5361 \u00b7 \u6458\u8981\uff08\u70b9\u51fb\u5361\u7247\u7ffb\u8f6c \u21bb\uff09<\/h3>\n    <div class=\"lm-grid2\">\n      <div class=\"lm-flip\">\n        <input type=\"checkbox\" id=\"zg-info\" class=\"lm-flip-input\">\n        <label class=\"lm-flip-card\" for=\"zg-info\">\n          <div class=\"lm-flip-inner\">\n            <div class=\"lm-flip-front\">\n              <h4>\u6b63\u9762 \u00b7 \u4fe1\u606f\u5361 \u21bb \u70b9\u6b64\u770b\u6458\u8981<\/h4>\n              <p><b>\u5ba2\u6237<\/b>\uff1a\u5468\u54e5\uff08\u4e24\u53e3\u5b50 \u00b7 \u5168\u540d\u5f85\u8865\uff09<\/p>\n              <p><b>\u6237\u578b<\/b>\uff1a\u4e09\u5ba4\u4e24\u5385 \u00b7 4 \u697c\u4e2d\u5c42\u975e\u9876\u697c \u00b7 \u5efa\u9762 114\u33a1 \/ \u5957\u5185\u7ea6 90\u33a1<\/p>\n              <p><b>\u5e38\u4f4f\u4eba\u53e3<\/b>\uff1a<span class=\"lm-big\">2 \u4eba<\/span><\/p>\n              <p><b>\u672c\u671f\u8303\u56f4<\/b>\uff1a\u53ea\u505a\u4e2d\u592e\u7a7a\u8c03\uff08\u4e00\u62d6\u56db \/ \u4e00\u62d6\u4e94\uff09\uff0c<strong>\u4e0d\u505a\u5730\u6696<\/strong><\/p>\n              <p><b>\u8bf4\u660e<\/b>\uff1a\u672c\u9875\u4e3a<strong>\u7eaf\u6280\u672f\u53c2\u8003\u65b9\u6848<\/strong>\uff0c\u53ea\u8bb2\u914d\u7f6e\u3001\u53c2\u6570\u4e0e\u6750\u6599\uff0c\u4e0d\u542b\u4efb\u4f55\u62a5\u4ef7\u4e0e\u91d1\u989d<\/p>\n              <span class=\"lm-tag lm-tag-b\">\u60a8\u7684\u753b\u50cf<\/span>\n            <\/div>\n            <div class=\"lm-flip-back\">\n              <h4>\u53cd\u9762 \u00b7 \u6458\u8981 \u21bb \u70b9\u6b64\u770b\u4fe1\u606f\u5361<\/h4>\n              <p class=\"lm-lead\">\u540c\u4e00\u53f0 125 \u5355\u98ce\u6247\u5916\u673a\uff0c\u914d\u4e09\u79cd\u5ba2\u9910\u5385\u5185\u673a\u65b9\u6848\uff0c\u5bf9\u6bd4\u7740\u770b<\/p>\n              <ul>\n                <li><b>\u914d\u7f6e A \u00b7 \u5ba2\u9910\u5385 RPIZ-71FSNAQD\/P<\/b>\u2014\u2014\u5171 4 \u53f0\u5185\u673a\uff0c\u5236\u51b7\u5408\u8ba1 14.7kW\uff0c\u8fde\u63a5\u7387 <b>117.6%<\/b>\uff08\u89c4\u8303\u5185\uff09\u3002<\/li>\n                <li><b>\u914d\u7f6e B \u00b7 \u5ba2\u9910\u5385 RPIZ-90FSNAQD\/P<\/b>\u2014\u2014\u5171 4 \u53f0\u5185\u673a\uff0c\u5236\u51b7\u5408\u8ba1 16.6kW\uff0c\u914d 140 \u5355\u98ce\u6247\u8fde\u63a5\u7387 <b>118.6%<\/b>\uff08\u89c4\u8303\u5185\uff09\u3002<\/li>\n                <li><b>\u914d\u7f6e C \u00b7 \u5ba2\u9910\u5385 RPIZ-71FSNAQD\/P + RPIZ-25FSNAQD\/P<\/b>\u2014\u2014\u5171 5 \u53f0\u5185\u673a\uff0c\u5236\u51b7\u5408\u8ba1 17.2kW\uff0c\u914d 140 \u5355\u98ce\u6247\u8fde\u63a5\u7387 <b>122.9%<\/b>\uff08\u89c4\u8303\u5185\uff09\u3002<\/li>\n                <li><b>\u4e09\u79cd\u4e00\u81f4<\/b>\uff1a\u4e3b\u5367 RPIZ-36FSNAQD\/P\u3001\u5367\u5ba4B RPIZ-22FSNAQD\/P\u3001\u5367\u5ba4C RPIZ-18FSNAQD\/P\uff1b\u5916\u673a A=RAS-125HRNAQ\u3001B\/C=RAS-140HRNAQ \u5355\u98ce\u6247\uff08\u5c3a\u5bf8\u5b8c\u5168\u76f8\u540c\uff09\u3002<\/li>\n                <li><b>\u672c\u4e66\u7ed3\u8bba<\/b>\uff1aB \/ C \u5df2\u914d <b>140 \u5355\u98ce\u6247<\/b>\u2014\u2014<strong>\u5c3a\u5bf8\u4e0e 125 \u5b8c\u5168\u76f8\u540c<\/strong>\uff0c\u673a\u4f4d\u4e0d\u53d7\u5f71\u54cd\uff0c\u8fde\u63a5\u7387\u5747\u56de\u5230\u89c4\u8303\u5185\u3002<\/li>\n              <\/ul>\n              <p>\u5dee\u5f02\u53ea\u5728\u300c\u5ba2\u9910\u5385\u653e\u591a\u5927\u3001\u653e\u51e0\u53f0\u300d\uff0c\u5176\u4f59\u623f\u95f4\u4e0e\u5916\u673a\u5e73\u53f0\u5b8c\u5168\u4e00\u81f4\u3002<\/p>\n            <\/div>\n          <\/div>\n        <\/label>\n        <div class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u7ffb\u9762 \u21bb<\/div>\n      <\/div>\n\n      <div class=\"lm-flip\">\n        <input type=\"checkbox\" id=\"zg-goal\" class=\"lm-flip-input\">\n        <label class=\"lm-flip-card\" for=\"zg-goal\">\n          <div class=\"lm-flip-inner\">\n            <div class=\"lm-flip-front\">\n              <h4>\u6b63\u9762 \u00b7 \u6210\u529f\u76ee\u6807 \u21bb \u70b9\u6b64\u770b\u6807\u51c6<\/h4>\n              <p>\u60a8\u8981\u7684\"\u6210\u529f\"\uff0c\u662f\uff1a<\/p>\n              <ul>\n                <li>\u2705 \u5916\u673a\u653e\u5f97\u4e0b\u2014\u2014\u8fd9\u662f\u60a8\u4e3b\u52a8\u6307\u5b9a\u5355\u98ce\u6247\u7684\u9996\u8981\u539f\u56e0<\/li>\n                <li>\u2705 \u5ba2\u9910\u5385 41.6\u33a1\uff08\u8fde\u9633\u53f0\u65e0\u95e8\uff09\u590f\u5929\u771f\u7684\u51c9\u5f97\u4e0b\u6765\u3001\u4e0d\u7559\u6b7b\u89d2<\/li>\n                <li>\u2705 \u4e09\u4e2a\u5367\u5ba4\u51ac\u5929\u5f00\u5236\u70ed\u4e5f\u591f\u6696\uff08\u517c\u987e\u5236\u70ed\uff09<\/li>\n                <li>\u2705 \u5185\u673a\u85cf\u8fdb\u540a\u9876\u540e\u597d\u770b\uff0c\u4e0d\u538b\u5c42\u9ad8\u3001\u4e0d\u505a\u5f88\u539a\u7684\u540a\u9876<\/li>\n                <li>\u2705 \u8f85\u6750\u54c1\u724c\u89c4\u683c\u644a\u5f00\u5199\u6e05\uff0c\u9690\u853d\u5de5\u7a0b\u53ef\u6838\u9a8c\u3001\u4e0d\u5077\u5de5\u51cf\u6599<\/li>\n                <li>\u2705 \u4e09\u79cd\u914d\u7f6e\u7684\u4f18\u52a3\u770b\u5f97\u61c2\uff0c\u80fd\u81ea\u5df1\u5224\u65ad\uff0c\u4e0d\u7528\u88ab\u9500\u552e\u5e26\u7740\u8d70<\/li>\n              <\/ul>\n            <\/div>\n            <div class=\"lm-flip-back\">\n              <h4>\u53cd\u9762 \u00b7 \u6211\u4eec\u7684\u4ea4\u4ed8\u6807\u51c6 \u21bb<\/h4>\n              <ul>\n                <li>\u6309 <b>\u5236\u51b7 150W\/\u33a1\u3001\u5236\u70ed 220W\/\u33a1<\/b> \u53e3\u5f84\u7b97\u91cf\uff0c\u9010\u623f\u5bf9\u8868\uff0c\u4e0d\u62cd\u8111\u888b\u3002<\/li>\n                <li>\u8fde\u63a5\u7387\u6309 <b>\u5185\u673a\u603b\u5bb9\u91cf \u00f7 \u5916\u673a\u5bb9\u91cf<\/b> \u8ba1\u7b97\uff0c\u89c4\u8303 50%\u2013130%\uff08\u7406\u60f3 90%\u2013110%\uff09\uff0c<b>\u8d85\u7ea2\u7ebf\u5982\u5b9e\u6807\u7ea2\uff0c\u4e0d\u85cf<\/b>\u3002<\/li>\n                <li>\u5185\u673a\u673a\u8eab\u9ad8\u5ea6\u3001\u8fdb\u6df1\u5168\u90e8\u5199\u660e\uff0c\u540a\u9876\u8be5\u7559\u591a\u5c11\u63d0\u524d\u4ea4\u5e95\uff0c\u4e0d\u4e0e\u6728\u5de5\u6253\u67b6\u3002<\/li>\n                <li>\u94dc\u7ba1\u54c1\u724c\u58c1\u539a\u3001\u4fdd\u6e29\u3001\u51b7\u5a92\u3001\u51b7\u51dd\u6c34\u7ba1\u5168\u90e8\u660e\u793a\uff0c<b>\u6c2e\u6c14\u4fdd\u62a4\u710a + \u5168\u7a0b\u62cd\u7167\u7559\u6863<\/b>\u3002<\/li>\n                <li>\u672c\u9875\u4e3a\u6280\u672f\u6807\uff0c<b>\u4e0d\u542b\u62a5\u4ef7<\/b>\uff1b\u4ef7\u683c\u4e0e\u5f53\u671f\u6d3b\u52a8\u4f18\u60e0\u53e6\u884c\u7ebf\u4e0b\u6c9f\u901a\u786e\u8ba4\u3002<\/li>\n              <\/ul>\n            <\/div>\n          <\/div>\n        <\/label>\n        <div class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u7ffb\u9762 \u21bb<\/div>\n      <\/div>\n    <\/div>\n\n    <h3 id=\"s1-need\">1.2 \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/h3>\n\n    <h3 id=\"s1-diag\">1.2.1 \u9700\u6c42 \u2192 \u75db\u70b9 \u2192 \u8bca\u65ad \u5bf9\u9f50\u8868<\/h3>\n    <div class=\"lm-scroll\">\n    <table class=\"lm-table\">\n      <thead><tr><th>\u60a8\u8bf4\u7684\u9700\u6c42<\/th><th>\u80cc\u540e\u771f\u6b63\u7684\u75db\u70b9<\/th><th>\u6211\u4eec\u7684\u8bca\u65ad<\/th><th>\u843d\u5230\u65b9\u6848\u54ea\u91cc<\/th><\/tr><\/thead>\n      <tbody>\n        <tr>\n          <th>\u53ea\u505a\u4e2d\u592e\u7a7a\u8c03\uff0c\u4e0d\u505a\u5730\u6696<\/th>\n          <td>\u9884\u7b97\u4e0e\u5de5\u671f\u805a\u7126\uff1b\u4f46\u51ac\u5929\u5367\u5ba4\u8fd8\u8981\u9760\u7a7a\u8c03\u5236\u70ed<\/td>\n          <td>\u7a7a\u8c03\u5185\u673a\u5fc5\u987b<b>\u517c\u987e\u5236\u70ed<\/b>\uff0c\u5367\u5ba4\u6309 <b>220W\/\u33a1<\/b> \u5236\u70ed\u53e3\u5f84\u9009\u673a\uff0c\u800c\u4e0d\u662f\u53ea\u6309\u5236\u51b7 150W\/\u33a1 \u9009\u2014\u2014\u8fd9\u6b63\u662f\u4e3b\u5367\u7528 36\u3001\u6b21\u5367\u7528 22\/18 \u800c\u4e0d\u662f\u66f4\u5c0f\u7684\u539f\u56e0<\/td>\n          <td>3.1 \u914d\u7f6e\u8868<\/td>\n        <\/tr>\n        <tr>\n          <th>\u4e3b\u52a8\u8981\u5355\u98ce\u6247\u5916\u673a\uff0c\u4e13\u95e8\u95ee\u957f\u5bbd\u9ad8<\/th>\n          <td>\u6015\u673a\u4f4d\u653e\u4e0d\u4e0b\uff1b\u5e02\u9762\u591a\u6570\u5927\u5916\u673a\u5f88\u9ad8\u5f88\u5bbd<\/td>\n          <td>\u8212\u4eab <b>\u5355\u98ce\u6247 125 \/ 140 = 770\u00d7980\u00d7360mm<\/b>\uff08\u4e0e\u540c\u5bb9\u91cf\u53cc\u98ce\u6247\u76f8\u6bd4\u77ee\u7ea6 610mm\uff09\uff0c\u673a\u4f4d\u9ad8\u5ea6\u8981\u6c42\u4ece \u22651600mm \u964d\u5230\u7ea6 950mm\u3002<b>\u8fd9\u4e2a\u8bc9\u6c42\u6210\u7acb\u4e14\u5408\u7406<\/b><\/td>\n          <td>3.2 \u5916\u673a\u9009\u578b<\/td>\n        <\/tr>\n        <tr>\n          <th>\u5ba2\u9910\u5385\u4ee5\u5236\u51b7\u4e3a\u4e3b<\/th>\n          <td>41.6\u33a1 \u5927\u5ba2\u5385\uff0c\u5355\u5236\u51b7\uff0c\u6309\u7167 150W\/\u33a1 \u7684\u51b7\u91cf\u8ba1\u7b97<\/td>\n          <td>\u5b98\u65b9\u9009\u578b\u53e3\u5f84\u4e2d 35\u201350\u33a1 \u7684\"\u5927\u5ba2\u5385\/\u9910\u5ba2\u4e00\u4f53\"\u6863 <b>63\/71 \u578b\u5373\u53ef<\/b><\/td>\n          <td>3.4 \u4e0d\u540c\u65b9\u6848\u4f18\u52bf<\/td>\n        <\/tr>\n        <tr>\n          <th>\u5176\u4ed6\u5367\u5ba4\u517c\u987e\u5236\u70ed<\/th>\n          <td>\u4e24\u53e3\u5b50\u5e38\u4f4f\uff0c\u5367\u5ba4\u662f\u957f\u65f6\u95f4\u505c\u7559\u533a\uff0c\u51ac\u5929\u4e0d\u80fd\u53ea\u9760\u88ab\u5b50<\/td>\n          <td>\u4e3b\u5367 15.4\u33a1 \u2192 \u5236\u70ed\u9700 3.39kW\uff0c36 \u578b\u5236\u70ed 4.0kW \u8986\u76d6\uff1b\u6b21\u5367B 2.29kW\u219222 \u578b\uff082.5kW\uff09\uff1b\u6b21\u5367C 1.85kW\u219218 \u578b\uff082.2kW\uff09\uff0c<b>\u4e09\u95f4\u5747\u7559\u6709\u4f59\u91cf<\/b><\/td>\n          <td>3.1 \u914d\u7f6e\u8868<\/td>\n        <\/tr>\n        <tr>\n          <th>\u8ffd\u6c42\u7f8e\u89c2<\/th>\n          <td>\u5185\u673a\u85cf\u5728\u540a\u9876\u91cc\uff0c\u4f46\u540a\u9876\u505a\u592a\u539a\u538b\u5c42\u9ad8\u3001\u505a\u592a\u7a84\u585e\u4e0d\u4e0b<\/td>\n          <td>\u8584\u578b\u98ce\u7ba1\u673a <b>\u673a\u8eab\u4ec5 192mm \u9ad8<\/b>\uff1b\u4f46\u8981\u6ce8\u610f <b>90 \u578b\u662f\u4f8b\u5916<\/b>\uff08218mm \u9ad8\u3001\u8fdb\u6df1 615mm\uff09\uff0c\u6bd4 63\/71 \u578b\uff08192mm \u9ad8\u3001\u8fdb\u6df1 447mm\uff09\u591a\u5360 168mm \u8fdb\u6df1<\/td>\n          <td>3.4 \u4e0d\u540c\u65b9\u6848\u4f18\u52bf<\/td>\n        <\/tr>\n        <tr>\n          <th>\u987e\u8651\uff1a\u8f85\u6750\u5077\u5de5\u51cf\u6599 \/ \u540e\u671f\u552e\u540e\u65e0\u4eba\u7ba1<\/th>\n          <td>\u4f4e\u4ef7\u62a5\u4ef7\u5e38\u7528\"\u8f85\u6750\u53e6\u8ba1\"\u505a\u6587\u7ae0\uff0c\u505a\u5b8c\u627e\u4e0d\u5230\u4eba<\/td>\n          <td>\u8f85\u6750\u54c1\u724c\u89c4\u683c\u5728 <b>3.6 \u5168\u90e8\u644a\u5f00\u5199\u660e<\/b>\uff0c\u53ef\u73b0\u573a\u9010\u9879\u6838\u9a8c\uff1b\u9f99\u8109\u81ea\u6709\u65bd\u5de5\u56e2\u961f\uff08\u975e\u5916\u5305\uff09+ \u9690\u853d\u5de5\u7a0b\u62cd\u7167\u7559\u6863 + \u53cc\u8282\u671f\u95f4<b>\u8bbe\u5907 10 \u5e74 + \u5b89\u88c5 10 \u5e74<\/b>\uff08\u5382\u5bb6\u515c\u5e95\uff09<\/td>\n          <td>3.5 \u8f85\u6750 \u00b7 \u2463 \u65bd\u5de5\u4ea4\u4ed8<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n\n    <div class=\"lm-footnav\">\n      <a href=\"#s1\">[\u2191 \u672c\u8282\u9876\u90e8]<\/a>\n      <a href=\"#s1-info\">[1.1 \u4fe1\u606f\u5361]<\/a>\n      <a href=\"#s3\">[\u4e0b\u4e00\u8282\uff1a\u89e3\u51b3\u65b9\u6848 \u2192]<\/a>\n    <\/div>\n  <\/section>\n\n  \n  <section class=\"lm-sec\" id=\"s3\">\n    <h2>\u2462 \u89e3\u51b3\u65b9\u6848<\/h2>\n    <div class=\"lm-toc\">\n      <a class=\"lm-toc-ov\" href=\"#s3\">\u25b8 \u672c\u8282\u603b\u89c8<\/a>\n      <a href=\"#s3-cfg\">\ud83e\udde9 \u4e09\u914d\u7f6e\u603b\u89c8<\/a>\n      <a href=\"#s3-outdoor\">\ud83d\udce6 \u5916\u673a\u9009\u578b<\/a>\n      <a href=\"#s3-inner\">\ud83e\uddf0 \u5185\u673a\u529f\u80fd<\/a>\n      <a href=\"#s3-pick\">\u2696\ufe0f \u4e0d\u540c\u65b9\u6848\u4f18\u52bf<\/a>\n      <a href=\"#s3-ac\">\ud83e\uddf0 \u7a7a\u8c03\u8f85\u6750<\/a>\n    <\/div>\n\n    \n    <h3 id=\"s3-cfg\">3.1 \u4e09\u79cd\u914d\u7f6e\u603b\u89c8\uff08\u540c\u4e00\u53f0\u5916\u673a \u00b7 \u53ea\u53d8\u5ba2\u9910\u5385\uff09<\/h3>\n    <p class=\"lm-lead\">\u4e09\u79cd\u914d\u7f6e\u7684<b>\u5916\u673a\u3001\u4e3b\u5367\u3001\u5367\u5ba4B\u3001\u5367\u5ba4C \u5b8c\u5168\u4e00\u81f4<\/b>\uff0c\u5dee\u522b\u53ea\u6709\u4e00\u4ef6\u4e8b\uff1a<b>\u5ba2\u9910\u5385\u653e\u591a\u5927\u3001\u653e\u4e00\u53f0\u8fd8\u662f\u4e24\u53f0<\/b>\u3002<\/p>\n    <div class=\"lm-scroll\">\n    <table class=\"lm-table\">\n      <thead><tr><th>\u9879\u76ee<\/th><th class=\"lm-col-a\">\u914d\u7f6e A<\/th><th>\u914d\u7f6e B<\/th><th class=\"lm-col-c\">\u914d\u7f6e C<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u5ba2\u9910\u5385\u5185\u673a<\/th><td class=\"lm-col-a\"><b>RPIZ-71FSNAQD\/P \u00d71<\/b><br>7.1 kW<\/td><td><b>RPIZ-90FSNAQD\/P \u00d71<\/b><br>9.0 kW<\/td><td class=\"lm-col-c\"><b>RPIZ-71FSNAQD\/P + RPIZ-25FSNAQD\/P<\/b><br>7.1 + 2.5 = 9.6 kW<\/td><\/tr>\n        <tr><th>\u5ba2\u9910\u5385\u5b9a\u4f4d<\/th><td class=\"lm-col-a\">\u4e3b\u6253\u5355\u5236\u51b7<br><span class=\"lm-sm\">71 \u578b\u4ee5\u590f\u5b63\u5236\u51b7\u4e3a\u4e3b<\/span><\/td><td>\u51b7\u6696\u517c\u987e \u00b7 \u4e00\u53f0\u5185\u673a<br><span class=\"lm-sm\">90 \u578b\u4e00\u53f0\u540c\u65f6\u7ba1\u51b7\u6696<\/span><\/td><td class=\"lm-col-c\">\u51b7\u6696\u517c\u987e \u00b7 \u53cc\u5185\u673a<br><span class=\"lm-sm\">\u6c14\u6d41\u5faa\u73af\u6bd4\u5355\u53f0\u66f4\u5747\u5300\uff0c\u5236\u70ed\u66f4\u5feb<\/span><\/td><\/tr>\n        <tr><th>\u4e3b\u5367<\/th><td colspan=\"3\">RPIZ-36FSNAQD\/P\uff083.6 kW\uff09<\/td><\/tr>\n        <tr><th>\u5367\u5ba4 B<\/th><td colspan=\"3\">RPIZ-22FSNAQD\/P\uff082.2 kW\uff09<\/td><\/tr>\n        <tr><th>\u5367\u5ba4 C<\/th><td colspan=\"3\">RPIZ-18FSNAQD\/P\uff081.8 kW\uff09<\/td><\/tr>\n        <tr><th>\u5185\u673a\u53f0\u6570<\/th><td class=\"lm-col-a\">4 \u53f0\uff08\u4e00\u62d6\u56db\uff09<\/td><td>4 \u53f0\uff08\u4e00\u62d6\u56db\uff09<\/td><td class=\"lm-col-c\">5 \u53f0\uff08\u4e00\u62d6\u4e94\uff09<\/td><\/tr>\n        <tr><th>\u5185\u673a\u603b\u5236\u51b7\u91cf<\/th><td class=\"lm-col-a\">14.7 kW<\/td><td>16.6 kW<\/td><td class=\"lm-col-c\">17.2 kW<\/td><\/tr>\n        <tr><th>\u5185\u673a\u603b\u5236\u70ed\u91cf<\/th><td class=\"lm-col-a\">16.7 kW<\/td><td>18.7 kW<\/td><td class=\"lm-col-c\">19.5 kW<\/td><\/tr>\n        <tr><th>\u5916\u673a<\/th><td class=\"lm-col-a\">RAS-125HRNAQ<br>12.5 \/ 14.0 kW<\/td><td>RAS-140HRNAQ<br>14.0 \/ 16.0 kW<\/td><td class=\"lm-col-c\">RAS-140HRNAQ<br>14.0 \/ 16.0 kW<\/td><\/tr>\n        <tr><th><b>\u5236\u51b7\u8fde\u63a5\u7387<\/b><\/th><td class=\"lm-col-a\"><b>117.6%<\/b><br>\u2705 \u89c4\u8303\u5185<\/td><td><b>118.6%<\/b><br>\u2705 \u914d 140 \u89c4\u8303\u5185<\/td><td class=\"lm-col-c\"><b>122.9%<\/b><br>\u2705 \u914d 140 \u89c4\u8303\u5185<\/td><\/tr>\n        <tr><th>\u5ba2\u9910\u5385\u4f9b\u51b7\u5f3a\u5ea6<\/th><td class=\"lm-col-a\">170 W\/\u33a1<br><span class=\"lm-sm\">\u8d85 150 \u53e3\u5f84<\/span><\/td><td>216 W\/\u33a1<\/td><td class=\"lm-col-c\">231 W\/\u33a1<\/td><\/tr>\n        <tr><th>\u5ba2\u9910\u5385\u5185\u673a\u5916\u5f62<br>\uff08\u9ad8\u00d7\u5bbd\u00d7\u6df1\uff09<\/th><td class=\"lm-col-a\">192 \u00d7 1180 \u00d7 447<\/td><td><b>218 \u00d7 (1480+82) \u00d7 615<\/b><br><span class=\"lm-sm\">\u8fdb\u6df1\u591a 168mm<\/span><\/td><td class=\"lm-col-c\">192\u00d71180\u00d7447<br>+ 192\u00d7700\u00d7447<\/td><\/tr>\n        <tr><th>\u5ba2\u9910\u5385\u566a\u97f3<\/th><td class=\"lm-col-a\">21 dB(A)<\/td><td>22 dB(A)<\/td><td class=\"lm-col-c\">21 dB(A) \/ 17 dB(A)<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n\n    <p class=\"lm-lead\"><b>\u8fde\u63a5\u7387\u600e\u4e48\u7b97\uff1a<\/b>\u5185\u673a\u603b\u5236\u51b7\u91cf \u00f7 \u5916\u673a\u540d\u4e49\u5236\u51b7\u91cf\u3002\u4f8b\uff1a\u914d\u7f6e A = 14.7 \u00f7 12.5 = 117.6%\u3002\u6c1f\u7cfb\u7edf\u89c4\u8303\u5141\u8bb8 <b>50%\u2013130%<\/b>\uff0c\u65e5\u7acb\u63a8\u8350\u7406\u60f3\u533a\u95f4 <b>90%\u2013110%<\/b>\u3002<\/p>\n\n    \n    <h3 id=\"s3-outdoor\">3.2 \u5916\u673a\u9009\u578b \u00b7 \u4e3a\u4ec0\u4e48\u662f\u300c\u8212\u4eab 125 \u5355\u98ce\u6247\u300d<\/h3>\n    <div class=\"lm-grid2\">\n      <div class=\"lm-flip\">\n        <input type=\"checkbox\" id=\"zg-od\" class=\"lm-flip-input\">\n        <label class=\"lm-flip-card\" for=\"zg-od\">\n          <div class=\"lm-flip-inner\">\n            <div class=\"lm-flip-front\">\n              <h4>\u6b63\u9762 \u00b7 \u65e5\u7acb\u8212\u4eab\u5916\u673a \u21bb \u70b9\u6b64\u770b\u53c2\u6570<\/h4>\n              <img decoding=\"async\" class=\"lm-sx-img\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1.jpg\" alt=\"\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247\u5916\u673a\">\n              <p><b>\u578b\u53f7<\/b>\uff1a\u8212\u4eab\u5355\u98ce\u6247 RAS-125HRNAQ \/ RAS-140HRNAQ\uff08<b>\u540c\u5c3a\u5bf8 770\u00d7980\u00d7360<\/b>\uff09<\/p>\n              <p><b>\u540d\u4e49\u5236\u51b7 \/ \u5236\u70ed<\/b>\uff1a125 \u2192 12.5 \/ 14.0 kW\u3000\uff5c\u3000140 \u2192 14.0 \/ 16.0 kW<\/p>\n              <p><b>APF<\/b>\uff1a125 \u2192 5.90\u3000\uff5c\u3000140 \u2192 5.80\uff08\u5747\u8d85\u4e00\u7ea7\u80fd\u6548\uff09<\/p>\n              <span class=\"lm-tag lm-tag-b\">\u60a8\u6307\u5b9a\u7684\u5355\u98ce\u6247<\/span>\n            <\/div>\n            <div class=\"lm-flip-back\">\n              <h4>\u53cd\u9762 \u00b7 \u53c2\u6570\u6e05\u5355 \u21bb \u70b9\u6b64\u770b\u4ea7\u54c1<\/h4>\n              <ul>\n                <li><b>\u5916\u5f62 H\u00d7W\u00d7D<\/b>\uff1a770 \u00d7 980 \u00d7 360 mm\uff08125 \u4e0e 140 \u5b8c\u5168\u76f8\u540c\uff09<\/li>\n                <li><b>\u8fd0\u884c\u566a\u97f3<\/b>\uff1a54 dB(A)\uff08\u4e24\u6863\u4e00\u81f4\uff09<\/li>\n                <li><b>\u51c0\u91cd \/ \u6700\u591a\u5185\u673a \/ \u914d\u7ba1<\/b>\uff1a125 \u2192 64kg \u00b7 8 \u53f0 \u00b7 60m\u3000\uff5c\u3000140 \u2192 71kg \u00b7 9 \u53f0 \u00b7 70m<\/li>\n                <li><b>\u9002\u7528\u9762\u79ef\uff08\u5b98\u7f51\uff09<\/b>\uff1a\u7ea6 100\u2013160\u33a1 \u00b7 \u4e09\u5ba4\u4e24\u5385<\/li>\n                <li><b>\u5185\u673a\u5e73\u53f0<\/b>\uff1aRPIZ-xxFSNAQD\/P \u8584\u578b\u98ce\u7ba1\u673a\uff08\u5e26\u6392\u6c34\u6cf5\uff09\uff1b\u672c\u6848\u5185\u673a\u578b\u53f7\uff1aRPIZ-18 \/ 22 \/ 25 \/ 36 \/ 63 \/ 71 \/ 90 FSNAQD\/P<\/li>\n                <li><b>\u591c\u95f4\u9759\u97f3<\/b>\uff1a22:00\u20138:00 \u6700\u591a\u518d\u964d 9dB<\/li>\n              <\/ul>\n              <p class=\"lm-sm\">\ud83d\udcd6 \u8212\u4eab\u4ea7\u54c1\u5b8c\u6574\u4ecb\u7ecd\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\u9f99\u8109\u5b98\u7f51\u8212\u4eab\u4ea7\u54c1\u9875<\/a>\u3002<\/p>\n            <\/div>\n          <\/div>\n        <\/label>\n        <div class=\"lm-flip-hint\">\u70b9\u51fb\u5361\u7247\u7ffb\u9762 \u21bb<\/div>\n      <\/div>\n\n    <\/div>\n\n    \n    <h3 id=\"s3-inner\">3.3 \u5185\u673a\u901a\u7528\u529f\u80fd\u7279\u6027\uff08\u8212\u4eab RPIZ-xxFSNAQD\/P \u00b7 \u4e09\u914d\u7f6e\u540c\u6b3e\u5185\u673a\uff09<\/h3>\n    <p class=\"lm-lead\">\u4e09\u79cd\u914d\u7f6e\u7684\u5185\u673a\u5747\u6765\u81ea\u540c\u4e00\u8584\u578b\u98ce\u7ba1\u673a\u5e73\u53f0\uff08\u5e26 DC \u76f4\u6d41\u6392\u6c34\u6cf5\uff09\uff0c\u4ee5\u4e0b\u529f\u80fd\u4e3a<b>\u8212\u4eab\u5185\u673a\u901a\u7528\u7279\u6027<\/b>\u2014\u2014\u9009\u914d\u9879\u5df2\u6807\u6ce8\uff0c\u65b9\u4fbf\u60a8\u6309\u9700\u52fe\u9009\u3002<\/p>\n    <div class=\"lm-grid2\">\n      <div class=\"lm-card\">\n        <h4>\ud83c\udf9b\ufe0f \u63a7\u6e29\u4e0e\u9664\u6e7f<\/h4>\n        <ul>\n          <li><b>\u7acb\u4f53\u611f\u6e29\u63a7\u5236<\/b>\uff1a\u5185\u673a\u6807\u914d\u51fa\u98ce\u6e29\u5ea6\u4f20\u611f\u5668 + \u56de\u98ce\u53e3\u6e29\u5ea6\u4f20\u611f\u5668 + 2000PLS \u9ad8\u7cbe\u5ea6\u7535\u5b50\u81a8\u80c0\u9600\uff0c\u7ebf\u63a7\u5668 \u00b10.5\u2103 \u7cbe\u51c6\u8bbe\u5b9a<\/li>\n          <li><b>\u7cbe\u51c6\u9664\u6e7f<\/b>\uff1a1% \u7cbe\u51c6\u8c03\u63a7\uff0c35%~90% \u5171 56 \u6863\uff1b\u652f\u6301\u81ea\u52a8\u9664\u6e7f\u3001\u4f4e\u6e29\u9664\u6e7f\uff08\u6700\u4f4e 10\u2103\uff0c\u9700\u642d\u6e7f\u5ea6\u4f20\u611f\u5668\u7ec4\u4ef6\uff09<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"lm-card\">\n        <h4>\ud83d\udee1\ufe0f \u51c0\u5316\u4e0e\u5065\u5eb7<\/h4>\n        <ul>\n          <li><b>\u667a\u80fd\u53cc\u51c0\u5316\uff08\u5185\u51c0\uff09<\/b>\uff1a\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01 + 60\u2103 \u9ad8\u6e29\u9664\u83cc\uff08\u6301\u7eed 30 \u5206\u949f\uff09<\/li>\n          <li><b>\u5916\u51c0\u7a7a\u6c14\uff08\u9009\u914d PE \u6a21\u5757\uff09<\/b>\uff1a\u8d1f\u79bb\u5b50\u9ad8\u6548\u9664 PM2.5\uff08\u53bb\u9664\u7387 94.46%\uff09\u3001\u9664\u7532\u919b\uff0874.9%\uff09\u3001\u9664\u5f02\u5473\u3001\u9664\u83cc\u6297\u6bd2\uff08\u5927\u80a0\u6746\u83cc 96.64% \/ \u91d1\u8461 93.88% \/ H3N2 \u6d41\u611f 96.85%\uff09<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"lm-card\">\n        <h4>\ud83d\udd07 \u5b89\u5168\u4e0e\u9759\u97f3<\/h4>\n        <ul>\n          <li><b>\u9632\u6f0f\u6c34\u5b89\u5168\u9884\u8b66<\/b>\uff1a\u6807\u914d DC \u76f4\u6d41\u6c34\u6cf5\uff081200mm \u9ad8\u626c\u7a0b\uff09+ \u6d6e\u5b50\u5f00\u5173\uff0c\u6392\u6c34\u4e0d\u7545\u9884\u8b66\u5e76\u505c\u673a<\/li>\n          <li><b>\u6781\u81f4\u9759\u97f3<\/b>\uff1a\u5ba4\u5185\u673a\u6700\u4f4e\u8fd0\u884c\u566a\u97f3 17 dB\uff1b\u8717\u58f3\u6574\u6d41\u788e\u6da1 + \u51b7\u5a92\u788e\u6ce1 + \u4f18\u5316\u8717\u58f3\u51fa\u98ce\u4e09\u5927\u964d\u566a\u6280\u672f<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"lm-card\">\n        <h4>\ud83c\udf2c\ufe0f \u9001\u98ce\u4e0e\u667a\u63a7<\/h4>\n        <ul>\n          <li><b>\u98ce\u901f\u4e0e\u9001\u98ce<\/b>\uff1a\u516d\u6863\u98ce\u901f\uff08PQA \u652f\u6301\u65e0\u6781\u8c03\u901f\uff09\uff0c\u53ef\u9009 3D \u73af\u7ed5\u7acb\u4f53\u9001\u98ce\u3001\u68ee\u6797\u98ce<\/li>\n          <li><b>\u8212\u5fc3\u7761\u7720\u6a21\u5f0f<\/b>\uff1a\u667a\u80fd\u8c03\u8282\u98ce\u91cf\u3001\u6e29\u6e7f\u5ea6\uff0c\u5475\u62a4\u7761\u7720<\/li>\n          <li><b>\u667a\u63a7<\/b>\uff1a\u9009\u914d WiFi \u7ebf\u63a7\u5668\u3001\u65e5\u7acb\u667a\u5bb6 APP\u3001\u8bed\u97f3\uff08\u534e\u4e3a \/ \u5c0f\u7c73 \/ \u767e\u5ea6\uff09<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-links\">\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\"><b>\ud83d\udcd6 \u65e5\u7acb\u8212\u4eab \u00b7 \u5b8c\u6574\u4ea7\u54c1\u624b\u518c<\/b><span>\u5355\u98ce\u6247\u5168\u6863\u4f4d\u53c2\u6570\u3001\u5185\u673a\u9009\u578b\u53e3\u5f84\u3001\u7ebf\u63a7\u5668\u4e0e\u51c0\u5316\u6a21\u5757\u9009\u914d\u2014\u2014\u672c\u9875\u5916\u673a\u4e0e\u5185\u673a\u53c2\u6570\u5747\u51fa\u81ea\u6b64\u9875\u3002<\/span><\/a>\n    <\/div>\n\n    \n    <h3 id=\"s3-pick\">3.4 \u4e0d\u540c\u65b9\u6848\u4f18\u52bf<\/h3>\n    <p class=\"lm-lead\">\u4e09\u79cd\u914d\u7f6e\u7684\u5916\u673a\u3001\u4e3b\u5367\u3001\u5367\u5ba4B\u3001\u5367\u5ba4C \u5b8c\u5168\u4e00\u81f4\uff0c\u5dee\u522b\u53ea\u5728\u5ba2\u9910\u5385\u3002\u4e0b\u9762\u628a\u6bcf\u4e00\u6b3e\u7684<strong>\u4f18\u70b9<\/strong>\u4e0e<strong>\u7f3a\u70b9<\/strong>\u5e76\u5217\u6446\u6e05\uff0c\u65b9\u4fbf\u60a8\u6309\u81ea\u5bb6\u4f5c\u606f\u81ea\u5df1\u62ff\u4e3b\u610f\uff08\u4e0d\u66ff\u60a8\u4e0b\u7ed3\u8bba\uff09\u3002<\/p>\n    <div class=\"lm-grid3\">\n      <div class=\"lm-card\">\n        <h4>\u914d\u7f6e A \u00b7 \u5ba2\u9910\u5385 RPIZ-71FSNAQD\/P\uff08\u4e00\u62d6\u56db\uff09<\/h4>\n        <p><b>\u2705 \u4f18\u70b9<\/b><\/p>\n        <ul>\n          <li>\u8fde\u63a5\u7387 <b>117.6% \u2705<\/b>\uff0c\u4e09\u79cd\u91cc\u552f\u4e00\u7528 125 \u5355\u98ce\u6247\u5c31\u5408\u89c4\u7684\u5b89\u5168\u914d\u7f6e<\/li>\n          <li>\u540a\u9876\u8f83\u53cb\u597d\uff1a192mm \u9ad8\u3001447mm \u8fdb\u6df1\uff0c\u5c42\u9ad8\u538b\u529b\u6700\u5c0f<\/li>\n          <li>\u4e00\u62d6\u56db\uff0c\u5185\u673a\u5c11\u4e00\u53f0\uff0c\u6545\u969c\u70b9\u66f4\u5c11\u3001\u521d\u88c5\u66f4\u7b80\u6d01<\/li>\n          <li>RAS-125HRNAQ\uff0864kg\uff09\u6bd4 140\uff0871kg\uff09\u66f4\u8f7b\uff0c\u673a\u4f4d\u627f\u91cd\u66f4\u5bbd\u677e<\/li>\n          <li>\u5ba2\u9910\u5385 71 \u578b<strong>\u5236\u51b7\u6548\u679c\u5f88\u597d<\/strong>\uff08\u7ea6 170 W\/\u33a1\uff0c\u8d85 150 \u53e3\u5f84\uff09\uff0c\u590f\u5929\u7eb3\u51c9\u5b8c\u5168\u591f\u7528\u2014\u2014\u8fd9\u662f\u5b83\u8f83\u7a33\u7684\u4e00\u9879<\/li>\n          <li><strong>\u6309\u9700\u6c42\u9009\u914d\u3001\u6027\u4ef7\u6bd4\u9ad8<\/strong>\uff1a\u60a8\u5bb6\u5ba2\u9910\u5385\u672c\u6765\u5c31\u4ee5\u5236\u51b7\u4e3a\u4e3b\u3001\u51ac\u5929\u5236\u70ed\u9760\u5367\u5ba4\u7a7a\u8c03\u8865\u4f4d\uff0c\u9009 71 \u521a\u597d\u5339\u914d\u771f\u5b9e\u9700\u6c42\u2014\u2014\u4e0d\u50cf B\/C \u90a3\u6837\u4e3a\u7528\u4e0d\u4e0a\u7684\u5236\u70ed\u80fd\u529b\u591a\u82b1\u94b1\uff0c\u662f\u4e09\u6b3e\u91cc\u521d\u88c5\u8f83\u7701\u3001\u957f\u671f\u8f83\u5212\u7b97\u7684<\/li>\n        <\/ul>\n        <p><b>\u26a0\ufe0f \u7f3a\u70b9<\/b><\/p>\n        <ul>\n          <li><strong>\u5236\u70ed\u6548\u679c\u8fbe\u4e0d\u5230\u8981\u6c42<\/strong>\uff1a71 \u578b\u4ee5\u5236\u51b7\u4e3a\u4e3b\uff0c\u5bf9\u8fde\u901a\u9633\u53f0\u7684\u5927\u7a7a\u95f4\u5236\u70ed\u5747\u5300\u6027\u4e00\u822c\uff0c\u51ac\u5929\u5ba2\u9910\u5385\u5355\u72ec\u9760\u5b83\u5236\u70ed\u4e0d\u7406\u60f3\u3002<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"lm-card\">\n        <h4>\u914d\u7f6e B \u00b7 \u5ba2\u9910\u5385 RPIZ-90FSNAQD\/P\uff08\u4e00\u62d6\u56db\uff09<\/h4>\n        <p><b>\u2705 \u4f18\u70b9<\/b><\/p>\n        <ul>\n          <li><strong>\u517c\u987e\u5236\u51b7\u4e0e\u5236\u70ed<\/strong>\uff1a\u4e00\u53f0 90 \u5185\u673a\u540c\u65f6\u7ba1\u51b7\u6696\uff0c\u5ba2\u9910\u5385\u51ac\u5929\u5236\u70ed\u4e5f\u6709\u9876\u6881\u67f1\u2014\u2014\u8fd9\u662f B \u76f8\u5bf9 A\uff08\u53ea\u5236\u51b7\uff09\u6700\u672c\u8d28\u7684\u4f18\u52bf<\/li>\n          <li>\u5ba2\u9910\u5385 <b>216 W\/\u33a1<\/b>\uff0c\u51b7\u91cf\u5145\u8db3\uff0c\u6bd4 150W\/\u33a1 \u5355\u5236\u51b7\u53e3\u5f84\u7559\u8db3\u4f59\u91cf<\/li>\n          <li>\u5355\u53f0\u5927\u5185\u673a\uff0c\u51fa\u98ce\u53e3\u96c6\u4e2d\u3001\u9020\u578b\u7b80\u6d01<\/li>\n          <li>\u8fde\u63a5\u7387 <b>118.6%\uff08\u914d 140 \u5355\u98ce\u6247\uff09\u2705<\/b>\uff0c\u56db\u53f0\u5168\u5f00\u4e5f\u4e0d\u6389\u80fd\u529b<\/li>\n        <\/ul>\n        <p><b>\u26a0\ufe0f \u7f3a\u70b9<\/b><\/p>\n        <ul>\n          <li><strong>90 \u578b 218\u00d7(1480+82)\u00d7615mm<\/strong>\uff0c\u6bd4 63\/71 \u578b\uff08192\u00d71180\u00d7447\uff09<strong>\u9ad8 26mm\u3001\u8fdb\u6df1\u591a 168mm<\/strong>\u2014\u2014\u5ba2\u9910\u5385\u540a\u9876\u8981\u505a\u5bbd\uff0c\u73b0\u573a\u6761\u4ef6\u662f\u5426\u6ee1\u8db3\uff0c\u6700\u7ec8\u662f\u5426\u7f8e\u89c2<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"lm-card\">\n        <h4>\u914d\u7f6e C \u00b7 \u5ba2\u9910\u5385 RPIZ-71FSNAQD\/P + RPIZ-25FSNAQD\/P\uff08\u4e00\u62d6\u4e94\uff09<\/h4>\n        <p><b>\u2705 \u4f18\u70b9<\/b><\/p>\n        <ul>\n          <li>\u5ba2\u9910\u5385 <b>231 W\/\u33a1<\/b>\uff0c\u4e09\u79cd\u91cc\u6700\u5145\u8db3\uff0c\u8986\u76d6 41.6\u33a1 \u8fde\u901a\u9633\u53f0\u6709\u4f59\u91cf<\/li>\n          <li><strong>\u53cc\u5185\u673a\u5206\u533a<\/strong>\u2014\u2014\u6c99\u53d1\u533a \/ \u9910\u684c\u533a\u5206\u9001\u98ce\uff0c41.6\u33a1 \u8fde\u901a\u7a7a\u95f4\u4e0d\u7559\u6b7b\u89d2\uff0c\u6c14\u6d41\u5faa\u73af\u6bd4\u5355\u53f0\u66f4\u5747\u5300<\/li>\n          <li>\u4e24\u53f0\u90fd\u662f 192mm \u9ad8\u3001447mm \u8fdb\u6df1\uff0c<strong>\u6bd4 90 \u578b\u7701 168mm \u8fdb\u6df1<\/strong>\uff0c\u540a\u9876\u8f83\u53cb\u597d<\/li>\n          <li>\u517c\u987e\u5236\u51b7\u4e0e\u5236\u70ed\uff0c\u53cc\u5185\u673a\u6c14\u6d41\u5faa\u73af\u66f4\u5747\u5300\u3001\u5236\u70ed\u5347\u6e29\u66f4\u5feb<\/li>\n          <li>\u8fde\u63a5\u7387 <b>122.9%\uff08\u914d 140 \u5355\u98ce\u6247\uff09\u2705<\/b><\/li>\n        <\/ul>\n        <p><b>\u26a0\ufe0f \u7f3a\u70b9<\/b><\/p>\n        <ul>\n          <li><strong>\u9020\u4ef7\u76f8\u5bf9 A\/B \u7565\u9ad8\u4e00\u4e9b<\/strong>\uff1a\u4e00\u62d6\u4e94\uff08\u6bd4\u4e00\u62d6\u56db\u591a\u4e00\u53f0\u5185\u673a\uff09\u4e14\u5916\u673a\u9700\u5347 140 \u5355\u98ce\u6247\uff0c\u8bbe\u5907\u91cf\u66f4\u5927\u3002<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n\n    \n    <h3 id=\"s3-ac\">3.5 \u4e2d\u592e\u7a7a\u8c03\u8f85\u6750\u6e05\u5355\uff08\u7eaf\u6c1f\u7cfb\u7edf \u00b7 \u5168\u90e8\u644a\u5f00\u53ef\u6838\u9a8c\uff09<\/h3>\n    <p class=\"lm-lead\">\u60a8\u987e\u8651\"\u8f85\u6750\u5077\u5de5\u51cf\u6599\"\u2014\u2014\u8fd9\u4e00\u8282\u5c31\u662f\u628a\u6bcf\u4e00\u9879\u5199\u660e\uff0c\u8fdb\u573a\u540e\u53ef\u4ee5\u9010\u9879\u5bf9\u7167\u9a8c\u6536\u3002<b>\u8f85\u6750\u6309\u6807\u51c6\u3001\u4e0d\u964d\u6807\u3002<\/b><\/p>\n    <div class=\"lm-scroll\">\n    <table class=\"lm-table\">\n      <thead><tr><th>\u90e8\u4f4d \/ \u6750\u6599<\/th><th>\u89c4\u683c\u6807\u51c6<\/th><th>\u4e3a\u4ec0\u4e48\u8fd9\u6837\u5b9a\uff08\u9632\u5077\u5de5\u8981\u70b9\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u51b7\u5a92\u94dc\u7ba1<\/th><td><b>\u9f99\u715c<\/b> \u00b7 \u8131\u6c27\u65e0\u7f1d\u7d2b\u94dc\u7ba1\uff08TP2 \u53bb\u6cb9\u94dc\u7ba1\uff09\u00b7 \u58c1\u539a\u6309\u7ba1\u5f84\u22650.8mm\uff08\u03a615.88 \u4e3b\u7ba1 \u22651.0mm\uff09<\/td><td>\u8584\u58c1\u7ba1\u8010\u538b\u4e0d\u8db3\u3001\u6613\u6c99\u773c\u6f0f\u6c1f\u3002\u54c1\u724c\u4e0e\u58c1\u539a\u5230\u573a\u53ef\u91cf\u3001\u53ef\u770b\u7ba1\u8eab\u55b7\u7801\u6807\u8bc6<\/td><\/tr>\n        <tr><th>\u94dc\u7ba1\u4fdd\u6e29<\/th><td><b>\u4f18\u83f2\u7279<\/b> \u00b7 \u6a61\u5851\u4fdd\u6e29\u7ba1 \u00b7 \u539a\u5ea6 \u226515mm\uff08B1 \u7ea7\u963b\u71c3\uff09<\/td><td>\u4fdd\u6e29\u8584\u4e86\u4f1a\u7ed3\u9732\u6ef4\u6c34\uff0c\u6ce1\u9876\u53d1\u9709\u2014\u2014\u8fd9\u662f\u6700\u5e38\u89c1\u7684\u5077\u5de5\u70b9<\/td><\/tr>\n        <tr><th>\u51b7\u51dd\u6c34\u7ba1<\/th><td><b>\u5ddd\u8def<\/b> UPVC \u7ed9\u6c34\u7ba1\uff08\u7981\u7528 PVC \u7ebf\u7ba1\u4ee3\u66ff\uff09\u00b7 \u5761\u5ea6 \u22651%<\/td><td>\u7528\u7ebf\u7ba1\u4ee3\u66ff\u4f1a\u8001\u5316\u6f0f\u6c34\uff1b\u5761\u5ea6\u4e0d\u591f\u4f1a\u5012\u5761\u79ef\u6c34\u3001\u6ce1\u540a\u9876<\/td><\/tr>\n        <tr><th>\u51b7\u5a92<\/th><td><b>\u675c\u90a6 \/ \u970d\u5c3c\u97e6\u5c14<\/b> R410A \u00b7 \u6309\u94ed\u724c\u91cf\u5b9a\u91cf\u8ffd\u52a0<\/td><td>\u5047\u5192\/\u56de\u6536\u51b7\u5a92\u4f1a\u4f24\u538b\u7f29\u673a\uff0c\u5fc5\u987b\u539f\u5382\u5bc6\u5c01\u94a2\u74f6<\/td><\/tr>\n        <tr><th>\u6c2e\u6c14\u4fdd\u62a4\u710a<\/th><td>\u94dc\u7ba1\u710a\u63a5\u5168\u7a0b\u5145\u6c2e\u4fdd\u62a4<\/td><td>\u4e0d\u5145\u6c2e\u4f1a\u5728\u7ba1\u5185\u4ea7\u751f\u6c27\u5316\u76ae\uff0c\u968f\u51b7\u5a92\u6d41\u52a8\u5835\u585e\u6bdb\u7ec6\u7ba1\/\u7535\u5b50\u81a8\u80c0\u9600\u2014\u2014<b>\u9690\u853d\u4e14\u81f4\u547d<\/b><\/td><\/tr>\n        <tr><th>\u6253\u538b\u68c0\u6f0f<\/th><td>\u6c2e\u6c14\u4fdd\u538b 4.0MPa \u00b7 \u7a33\u538b \u226524h \u00b7 \u538b\u964d \u22640.02MPa<\/td><td>\u53ea\u505a\u771f\u7a7a\u4e0d\u4fdd\u538b = \u6f0f\u70b9\u5e26\u75c5\u4ea4\u4ed8\uff0c\u590f\u5929\u624d\u66b4\u9732<\/td><\/tr>\n        <tr><th>\u62bd\u771f\u7a7a<\/th><td>\u771f\u7a7a\u5ea6 \u2264-0.1MPa \u00b7 \u4fdd\u6301 \u22652h<\/td><td>\u771f\u7a7a\u4e0d\u5f7b\u5e95\uff0c\u7cfb\u7edf\u542b\u6c34\u6c7d \u2192 \u51b0\u5835 \/ \u538b\u7f29\u673a\u9178\u5316<\/td><\/tr>\n        <tr><th>\u5206\u6b67\u7ba1<\/th><td><b>\u9f99\u715c<\/b> \u5206\u6b67\u7ba1\uff08\u6309\u673a\u578b\u914d\u4e13\u7528\u578b\u53f7\uff09<\/td><td>\u526f\u5382\u5206\u6b67\u7ba1\u5206\u6d41\u4e0d\u5747\uff0c\u8fdc\u7aef\u5185\u673a\u6548\u679c\u5dee<\/td><\/tr>\n        <tr><th>\u7535\u6e90\u7ebf \/ \u4fe1\u53f7\u7ebf<\/th><td><b>\u5854\u724c<\/b> \u56fd\u6807\u94dc\u82af\u7ebf \u00b7 \u5185\u5916\u673a\u72ec\u7acb\u56de\u8def \u00b7 \u5c4f\u853d\u4fe1\u53f7\u7ebf<\/td><td>\u7ebf\u5f84\u4e0d\u8db3\u4f1a\u538b\u964d\u8df3\u95f8\uff1b\u4fe1\u53f7\u7ebf\u4e0e\u7535\u6e90\u7ebf\u6df7\u8d70\u4f1a\u5e72\u6270\u901a\u8baf<\/td><\/tr>\n        <tr><th>\u540a\u88c5<\/th><td><b>\u5b9a\u5236<\/b> \u56fd\u6807\u9540\u950c\u540a\u6746 + \u51cf\u9707\u57ab \u00b7 \u5185\u673a\u53cc\u87ba\u6bcd\u9632\u677e<\/td><td>\u540a\u6746\u4e0d\u51cf\u9707 \u2192 \u8fd0\u884c\u5171\u632f\u566a\u97f3\uff1b\u5355\u87ba\u6bcd\u4f1a\u9010\u5e74\u677e\u52a8<\/td><\/tr>\n        <tr><th>\u7ebf\u63a7\u5668<\/th><td>\u6bcf\u53f0\u5185\u673a\u914d\u72ec\u7acb <b>\u65e5\u7acb Wi-Fi \u578b\u7ebf\u63a7\u5668\uff08PC-P1HVQA\uff0c\u5168\u7cfb\u901a\u7528\uff09<\/b><\/td><td>\u4e00\u63a7\u591a\u662f\u7701\u94b1\u505a\u6cd5\uff0c\u4f1a\u5931\u53bb\u5206\u533a\u72ec\u7acb\u63a7\u6e29\uff1bWi-Fi \u578b\u652f\u6301\u624b\u673a\u8fdc\u7a0b\u4e0e APP \u8054\u52a8<\/td><\/tr>\n        <tr><th>\u51fa\u98ce\u53e3 \/ \u56de\u98ce\u53e3<\/th><td><b>\u5b9a\u5236<\/b> ABS \u9632\u7ed3\u9732<\/td><td>\u51fa\u56de\u98ce\u592a\u8fd1\u4f1a\u6c14\u6d41\u77ed\u8def\uff0c\u51b7\u98ce\u76f4\u63a5\u88ab\u5438\u56de\uff0c\u623f\u95f4\u4e0d\u51c9<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <\/div>\n    <div class=\"lm-footnav\">\n      <a href=\"#s3\">[\u2191 \u672c\u8282\u9876\u90e8]<\/a>\n      <a href=\"#s3-cfg\">[3.1 \u4e09\u914d\u7f6e]<\/a>\n      <a href=\"#s3-inner\">[3.3 \u5185\u673a\u529f\u80fd]<\/a>\n      <a href=\"#s3-pick\">[3.4 \u4e0d\u540c\u65b9\u6848\u4f18\u52bf]<\/a>\n      <a href=\"#s3-ac\">[3.5 \u8f85\u6750]<\/a>\n      <a href=\"#s6\">[\u4e0b\u4e00\u8282 \u2192]<\/a>\n    <\/div>\n  <\/section>\n\n  \n  <section class=\"lm-sec\" id=\"s6\">\n    <h2>\u2463 \u65bd\u5de5\u4ea4\u4ed8\u670d\u52a1\u4fdd\u969c<\/h2>\n    <div class=\"lm-toc\">\n      <a class=\"lm-toc-ov\" href=\"#s6\">\u25b8 \u672c\u8282\u603b\u89c8<\/a>\n      <a href=\"#s6-stage\">\ud83d\udd27 \u7cbe\u5de5\u516d\u6b65\u6cd5<\/a>\n      <a href=\"#s6-design\">\ud83d\udcd0 \u8bbe\u8ba1\u65b9\u6848\u56fe<\/a>\n      <a href=\"#s6-shot\">\ud83d\udcf7 \u65bd\u5de5\u5b9e\u666f<\/a>\n      <a href=\"#s6-accept\">\ud83d\udccb \u76d1\u7406\u9a8c\u6536<\/a>\n      <a href=\"#s6-cert\">\ud83c\udfc5 \u6388\u6743\u8bc1\u4e66<\/a>\n    <\/div>\n\n    <h3 id=\"s6-stage\">6.1 \u7cbe\u5de5\u516d\u6b65\u6cd5 + 2<\/h3>\n    <div class=\"lm-stages\">\n      <div class=\"lm-stage\"><div class=\"lm-no\">1<\/div><div><b>\u73b0\u573a\u52d8\u6d4b<\/b><p>\u590d\u6838\u623f\u95f4\u9762\u79ef\u3001\u671d\u5411\u3001\u5c42\u9ad8\u3001<b>\u673a\u4f4d\u5c3a\u5bf8\u4e0e\u627f\u91cd<\/b>\uff08\u60a8\u6700\u5173\u5fc3\u7684\u4e00\u9879\uff09\u3001\u7535\u8868\u5bb9\u91cf\uff0c\u786e\u8ba4\u4e3b\u673a\u4e0e\u5185\u673a\u6700\u7ec8\u6863\u4f4d\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">2<\/div><div><b>\u6df1\u5316\u8bbe\u8ba1<\/b><p>\u51fa\u7ba1\u8def\u8d70\u5411\u56fe\u3001\u5185\u673a\u5b9a\u4f4d\u56fe\u3001\u540a\u9876\u914d\u5408\u5c3a\u5bf8\u56fe\uff0c\u4e0e\u6728\u5de5\/\u6c34\u7535\u4ea4\u5e95<b>\u5185\u673a\u673a\u8eab\u9ad8\u5ea6\u4e0e\u8fdb\u6df1<\/b>\uff0c\u907f\u514d\u540a\u9876\u505a\u4e0d\u4e0b\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">3<\/div><div><b>\u9690\u853d\u65bd\u5de5<\/b><p>\u94dc\u7ba1<b>\u6c2e\u6c14\u4fdd\u62a4\u710a<\/b>\u3001\u4fdd\u6e29\u5168\u5305\u3001\u51b7\u51dd\u6c34\u7ba1\u5761\u5ea6\u63a7\u5236\uff0c\u5168\u7a0b\u62cd\u7167\u7559\u6863\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">4<\/div><div><b>\u6253\u538b\u9a8c\u6536<\/b><p>\u6c2e\u6c14\u4fdd\u538b 4.0MPa \u7a33\u538b \u226524h\u3001\u538b\u964d \u22640.02MPa\uff1b\u62bd\u771f\u7a7a \u2264-0.1MPa \u4fdd\u6301 \u22652h\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">5<\/div><div><b>\u8c03\u8bd5\u4ea4\u4ed8<\/b><p>\u9010\u53f0\u5185\u673a\u8bd5\u8fd0\u884c\u3001\u7ebf\u63a7\u5668\u4e0e\u8054\u52a8\u8c03\u8bd5\u3001\u51fa\u56de\u98ce\u6e29\u5dee\u5b9e\u6d4b\uff0c\u4ea4\u4ed8\u4f7f\u7528\u57f9\u8bad\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">6<\/div><div><b>\u5efa\u7acb\u6863\u6848<\/b><p>\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u5f52\u6863\uff0c\u542b\u914d\u7f6e\u6e05\u5355\u3001<b>\u9690\u853d\u5de5\u7a0b\u7167\u7247<\/b>\u3001\u9a8c\u6536\u8bb0\u5f55\u3001\u4fdd\u4fee\u8fb9\u754c\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">+1<\/div><div><b>\u5e74\u5ea6\u56de\u8bbf<\/b><p>\u5236\u51b7\u5b63\u524d\/\u91c7\u6696\u5b63\u524d\u5404\u4e00\u6b21\u4e3b\u52a8\u56de\u8bbf\uff0c\u68c0\u67e5\u538b\u529b\u3001\u6e05\u6d17\u8fc7\u6ee4\u7f51\u3002<\/p><\/div><\/div>\n      <div class=\"lm-stage\"><div class=\"lm-no\">+2<\/div><div><b>\u80fd\u8017\u8ddf\u8e2a<\/b><p>\u6301\u7eed\u8ddf\u8e2a\u7528\u80fd\u6570\u636e\uff0c\u5f02\u5e38\u53ca\u65f6\u9884\u8b66\uff1b\u6863\u6848\u6301\u7eed\u66f4\u65b0\u3002<\/p><\/div><\/div>\n    <\/div>\n\n    <h4 id=\"s6-design\">\ud83d\udcd0 \u8bbe\u8ba1\u65b9\u6848\u56fe\uff08\u7a7a\u8c03\u7cfb\u7edf\u56fe\u793a\u4f8b\uff09<\/h4>\n    <p class=\"lm-lead\">\u516d\u6b65\u6cd5<b>\u7b2c 2 \u6b65\u300c\u6df1\u5316\u8bbe\u8ba1\u300d<\/b>\u4f1a\u8f93\u51fa\u7a7a\u8c03\u7cfb\u7edf\u56fe\u3001\u5185\u673a\u5b9a\u4f4d\u56fe\u4e0e\u540a\u9876\u914d\u5408\u5c3a\u5bf8\u56fe\u3002\u4e0b\u56fe\u662f\u540c\u7c7b\u578b\u9879\u76ee\u7684\u7cfb\u7edf\u56fe\u793a\u4f8b\uff0c\u8ba9\u60a8\u5148\u770b\u6e05\u65b0\u98ce \/ \u51b7\u5a92\u7ba1\u8def\u5728\u540a\u9876\u91cc\u662f\u600e\u4e48\u8d70\u7684\u3002<\/p>\n    <div class=\"lm-gallery\">\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhhy-hls-ktxtsjt.jpg\" alt=\"\u7a7a\u8c03\u7cfb\u7edf\u56fe\u793a\u4f8b\"><figcaption>\u7a7a\u8c03\u7cfb\u7edf\u56fe\uff08\u793a\u4f8b \u00b7 \u975e\u672c\u6848\uff09<\/figcaption><\/figure>\n    <\/div>\n    <p class=\"lm-note\">\ud83d\udccc \u5468\u54e5\u9879\u76ee\u5c1a\u5904\u65b9\u6848\u9636\u6bb5\u3001\u672a\u8fdb\u573a\u590d\u5c3a\uff0c\u4e0a\u56fe\u4e3a<b>\u540c\u7c7b\u578b\u9879\u76ee\u793a\u4f8b\u56fe\uff08\u975e\u672c\u6848\uff09<\/b>\u3002\u672c\u6848\u8fdb\u573a\u540e\u7531\u9f99\u8109\u51fa\u5177\u4e13\u5c5e\u7a7a\u8c03\u7cfb\u7edf\u56fe \/ \u5185\u673a\u5b9a\u4f4d\u56fe\uff0c\u4e0e\u6728\u5de5\u6c34\u7535\u4ea4\u5e95\u540e\u518d\u65bd\u5de5\u3002<\/p>\n\n        <h4>\ud83d\udcf7 \u65bd\u5de5\u5b9e\u666f\u53c2\u8003\uff08\u5bf9\u5e94\u4e0a\u9762\u516d\u6b65\u6cd5 \u00b7 \u5176\u4ed6\u5de5\u5730\u793a\u4f8b \u00b7 8 \u5f20\uff09<\/h4>\n    <p class=\"lm-lead\">\u516d\u6b65\u6cd5\u91cc<b>\u7b2c 3 \u6b65\u9690\u853d\u65bd\u5de5<\/b>\u4e0e<b>\u7b2c 4 \u6b65\u6253\u538b\u9a8c\u6536<\/b>\u505a\u5b8c\u5c31\u4f1a\u88ab\u540a\u9876\u6c38\u4e45\u76d6\u4f4f\uff0c\u662f\u4ea4\u4ed8\u540e\u552f\u4e00\u518d\u4e5f\u770b\u4e0d\u5230\u7684\u73af\u8282\u3002\u4e0b\u9762\u628a\u8fd9\u4e24\u6b65\u7684\u6807\u51c6\u505a\u6cd5\u644a\u5f00\u7ed9\u60a8\u770b\u3002<\/p>\n    <div class=\"lm-gallery\">\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lyyh-lls-njazsj-08.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lyyh-lls-njazsj-06.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lyyh-lls-njazsj-02.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ryglld3q-wls-njazsj-05.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/ryglld3q-wls-njazsj-04.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tfsc-mls-sxnjazsj-1.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/fdkyjc-lls-sxnjazsj-5.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/fdkyjc-lls-sxnjazsj-4.jpg\" alt=\"\u7a7a\u8c03\u65bd\u5de5\u5b9e\u666f\u53c2\u8003\"><figcaption>\u65bd\u5de5\u5b9e\u666f\u53c2\u8003 \u00b7 \u5176\u4ed6\u5de5\u5730\uff08\u975e\u672c\u6848\u5b9e\u62cd\uff09<\/figcaption><\/figure>\n    <\/div>\n    <p class=\"lm-note\" id=\"s6-shot\">\ud83d\udccc \u5468\u54e5\u9879\u76ee\u5c1a\u5904\u65b9\u6848\u9636\u6bb5\u3001\u672a\u8fdb\u573a\u65bd\u5de5\uff0c\u4ee5\u4e0a 8 \u5f20\u5747\u4e3a\u672c\u54c1\u724c<b>\u5176\u4ed6\u5df2\u4ea4\u4ed8\u5de5\u5730\u7684\u65bd\u5de5\u793a\u4f8b<\/b>\uff08<b>\u975e\u672c\u6848\u5b9e\u62cd<\/b>\uff09\uff0c\u7528\u4e8e\u5c55\u793a\u9f99\u8109\u7cbe\u5de5\u5de5\u827a\u6807\u51c6\u3002\u672c\u6848\u8fdb\u573a\u540e\u5c06\u7531\u9f99\u8109\u81ea\u6709\u56e2\u961f\u5b9e\u62cd\u5f52\u6863\uff0c\u66ff\u6362\u4e3a\u672c\u9879\u76ee\u771f\u5b9e\u65bd\u5de5\u7167\uff08\u22653 \u5f20\uff09\u3002<\/p>\n    <h4 id=\"s6-accept\">\ud83d\udccb \u76d1\u7406\u9a8c\u6536\u8bb0\u5f55\uff08\u5176\u4ed6\u5de5\u5730\u793a\u4f8b\uff09<\/h4>\n    <p class=\"lm-lead\">\u516d\u6b65\u6cd5<b>\u7b2c 4 \u6b65\u300c\u6253\u538b\u9a8c\u6536\u300d<\/b>\u5b8c\u6210\u540e\uff0c\u7531\u76d1\u7406\u72ec\u7acb\u62bd\u68c0\u5e76\u51fa\u5177\u9a8c\u6536\u8bb0\u5f55\u3002\u4e0b\u9762\u4e09\u5f20\u662f\u540c\u7c7b\u578b\u9879\u76ee\u7684\u62bd\u68c0\u4e0e\u9a8c\u6536\u5355\u793a\u4f8b\u3002<\/p>\n    <div class=\"lm-gallery\">\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gw-jyscj-tls-danqibaohuhan01-1.jpg\" alt=\"\u76d1\u7406\u62bd\u68c0\u00b7\u5355\u673a\u4fdd\u62a4\"><figcaption>\u76d1\u7406\u62bd\u68c0 \u00b7 \u5355\u673a\u4fdd\u62a4\uff08\u793a\u4f8b\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/gw-jyscj-tls-waijianzhuang01.jpg\" alt=\"\u76d1\u7406\u9a8c\u6536\u00b7\u5916\u673a\u5b89\u88c5\"><figcaption>\u76d1\u7406\u9a8c\u6536 \u00b7 \u5916\u673a\u5b89\u88c5\uff08\u793a\u4f8b\uff09<\/figcaption><\/figure>\n      <figure class=\"lm-shot\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/snys-zls-ysd.jpg\" alt=\"\u9690\u853d\u5de5\u7a0b\u00b7\u9a8c\u6536\u5355\"><figcaption>\u9690\u853d\u5de5\u7a0b \u00b7 \u9a8c\u6536\u5355\uff08\u793a\u4f8b\uff09<\/figcaption><\/figure>\n    <\/div>\n    <p class=\"lm-note\">\ud83d\udccc \u4ee5\u4e0a\u4e3a<b>\u5176\u4ed6\u5df2\u4ea4\u4ed8\u5de5\u5730\u7684\u76d1\u7406\u62bd\u68c0 \/ \u9a8c\u6536\u793a\u4f8b\uff08\u975e\u672c\u6848\uff09<\/b>\uff0c\u7528\u4e8e\u5c55\u793a\u9f99\u8109\u300c\u76d1\u7406\u72ec\u7acb\u9a8c\u6536\u300d\u7684\u4ea4\u4ed8\u6807\u51c6\u3002\u672c\u6848\u65bd\u5de5\u540e\u7531\u76d1\u7406\u51fa\u5177\u4e13\u5c5e\u9a8c\u6536\u8bb0\u5f55\uff0c\u5e76\u5165\u300a\u9879\u76ee\u6863\u6848\u4e66\u300b\u3002<\/p>\n\n    <div class=\"lm-links\">\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\"><b>\ud83d\udd27 \u9f99\u8109\u7cbe\u5de5\u516d\u6b65\u6cd5\uff08\u8be6\u89e3\uff09<\/b><span>\u52d8\u6d4b\u2192\u8bbe\u8ba1\u2192\u65bd\u5de5\u2192\u6253\u538b\u2192\u8c03\u8bd5\u2192\u5efa\u6863\u7684\u5b8c\u6574\u4ea4\u4ed8\u6807\u51c6\u4e0e\u62cd\u7167\u7559\u6863\u8981\u6c42\uff0c\u5bf9\u5e94\u4e0a\u65b9 6.1\u3002<\/span><\/a>\n    <\/div>\n    <div class=\"lm-ok-line\">\n      <strong>\u8d28\u4fdd \u00b7 \u53cc\u8282\u6d3b\u52a8\uff08\u5382\u5bb6\u515c\u5e95\uff09\uff1a<\/strong>\n      <b>\u8bbe\u5907 10 \u5e74 + \u5b89\u88c5 10 \u5e74<\/b>\u2014\u2014\u7531\u5382\u5bb6\u515c\u5e95\u7684\"\u53cc 10 \u5e74\"\uff0c\u8bbe\u5907\u4e0e\u5b89\u88c5\u5206\u5f00\u627f\u4fdd\uff0c\u907f\u514d\"\u8bbe\u5907\u5382\u5bb6\u4fdd\u3001\u5b89\u88c5\u6ca1\u4eba\u7ba1\"\u7684\u626f\u76ae\u3002\n      \u6d3b\u52a8\u7a97\u53e3\u81f3 <b>2026-10-12<\/b> \u622a\u6b62\uff0c\u60a8\u56fd\u5e86\u671f\u95f4\u5230\u5e97\u5b9a\u593a\u53ef\u4eab\u3002\n    <\/div>\n\n    <h3 id=\"s6-cert\">6.2 \u65e5\u7acb\u6388\u6743\u8bc1\u4e66\uff085 \u5f20\u9f50\u5168\uff09<\/h3>\n    <div class=\"lm-certs\">\n      <div class=\"lm-cert\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7279\u7ea6\u7ecf\u9500\u6388\u6743\"><\/div>\n      <div class=\"lm-cert\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-shuishushi-teyuejingxiao.jpg\" alt=\"\u65e5\u7acb\u6c34\u7cfb\u7edf\u7279\u7ea6\u7ecf\u9500\u6388\u6743\"><\/div>\n      <div class=\"lm-cert\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\"><\/div>\n      <div class=\"lm-cert\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\"><\/div>\n      <div class=\"lm-cert\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-anzhuang-teyaoanzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u5b89\u88c5\u6388\u6743\"><\/div>\n    <\/div>\n    <p class=\"lm-note\">\ud83d\udccc \u6388\u6743\u8d44\u8d28\u662f\"\u540e\u671f\u552e\u540e\u6709\u4eba\u7ba1\"\u7684\u786c\u51ed\u8bc1\u2014\u2014\u9f99\u8109\u4e3a\u65e5\u7acb\u6210\u90fd<b>\u76f4\u8425\u6388\u6743\u7ecf\u9500\u5546<\/b>\uff0c\u975e\u4e8c\u7ea7\u4ee3\u7406\uff0c\u5b89\u88c5\u4e0e\u552e\u540e\u7531\u81ea\u6709\u56e2\u961f\u627f\u62c5\u3002<\/p>\n\n    <div class=\"lm-footnav\">\n      <a href=\"#s6\">[\u2191 \u672c\u8282\u9876\u90e8]<\/a>\n      <a href=\"#s6-stage\">[6.1 \u516d\u6b65\u6cd5]<\/a>\n      <a href=\"#s6-design\">[6.1 \u8bbe\u8ba1\u56fe]<\/a>\n      <a href=\"#s6-accept\">[6.1 \u76d1\u7406\u9a8c\u6536]<\/a>\n      <a href=\"#s6-cert\">[6.2 \u6388\u6743\u8bc1\u4e66]<\/a>\n      <a href=\"#s7\">[\u4e0b\u4e00\u8282 \u2192]<\/a>\n    <\/div>\n  <\/section>\n\n  \n  <section class=\"lm-sec\" id=\"s7\">\n    <h2>\u2464 \u6848\u4f8b\u8fed\u4ee3\u9a8c\u8bc1<\/h2>\n    <div class=\"lm-toc\">\n      <a class=\"lm-toc-ov\" href=\"#s7\">\u25b8 \u672c\u8282\u603b\u89c8<\/a>\n      <a href=\"#s7-case\">\ud83d\udd17 \u76f8\u5173\u6848\u4f8b<\/a>\n    <\/div>\n\n    <h3 id=\"s7-case\">7.1 \u540c\u5916\u673a \/ \u540c\u914d\u7f6e \/ \u540c\u6237\u578b\u6848\u4f8b\u53c2\u8003<\/h3>\n    <div class=\"lm-links\">\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><b>\u6848\u4f8b\u4e2d\u5fc3\u805a\u5408\u9875<\/b><span>\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b\uff0c\u542b\u8212\u4eab\u5404\u6863\u4f4d\u5b8c\u5de5\u5b9e\u62cd\u4e0e\u56de\u8bbf\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10636\" target=\"_blank\"><b>\u91d1\u725b\u533a\u4e1c\u539f\u4eb2\u4eb2\u91cc 80\u33a1 \u5e73\u5c42\uff5c\u65e5\u7acb\u8212\u4eab 125 \u4e00\u62d6\u56db\u5b8c\u5de5\u5b9e\u666f<\/b><span>\u4e0e\u672c\u6848<b>\u540c\u4e3a\u8212\u4eab 125\u3001\u540c\u4e3a\u4e00\u62d6\u56db\u3001\u540c\u4e3a\u5c0f\u9762\u79ef\u5e73\u5c42<\/b>\u2014\u2014\u6700\u76f4\u63a5\u7684\u5bf9\u6807\u53c2\u8003\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10955\" target=\"_blank\"><b>\u76db\u548c\u6797\u8bed\u5317\u533a\uff5c\u8212\u4eab\u5355\u98ce\u6247\u5916\u673a\u62d6\u4e94\u6848\u4f8b<\/b><span>\u4e0e\u672c\u6848\"\u5ba2\u6237\u6307\u5b9a\u5355\u98ce\u6247\"\u7684\u8bc9\u6c42\u5b8c\u5168\u4e00\u81f4\uff0c\u53ef\u770b\u5355\u98ce\u6247\u5916\u673a\u7684\u771f\u5b9e\u673a\u4f4d\u5b89\u88c5\u6548\u679c\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10918\" target=\"_blank\"><b>\u91d1\u725b\u533a\u5e78\u798f\u62fe\u5149\u4e8c\u671f 85\u33a1 \u5957\u56db\uff5c\u8212\u4eab 140 \u5355\u98ce\u6247\u4e00\u62d6\u56db<\/b><span>\u5bf9\u5e94\u672c\u65b9\u6848\"\u4f18\u5316\u2460\uff1a\u5916\u673a\u5347 140 \u5355\u98ce\u6247\"\u2014\u2014\u540c\u6837\u662f\u5355\u98ce\u6247\u3001\u540c\u6837\u662f 4 \u53f0\u5185\u673a\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10854\" target=\"_blank\"><b>\u6e05\u51e4\u65f6\u4ee3\u57ce\uff5c\u6b66\u4faf\u5927\u6e90 \u65e5\u7acb\u8212\u4eab 125 \u4e00\u62d6\u4e09\u5b8c\u5de5\u5b9e\u62cd<\/b><span>\u540c\u4e3a\u8212\u4eab 125 \u6863\u4f4d\uff0c\u53ef\u53c2\u8003\u5916\u673a\u673a\u4f4d\u4e0e\u7ba1\u8def\u8d70\u5411\u7684\u5b9e\u9645\u5904\u7406\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10250\" target=\"_blank\"><b>\u9e93\u6e56\u6c84\u5cb8\uff5c\u53cc\u6d41\u533a \u65e5\u7acb\u8212\u4eab 140 \u4e00\u62d6\u56db\u5b8c\u5de5\u5b9e\u62cd<\/b><span>\u8212\u4eab 140 \u6863\u4e00\u62d6\u56db\uff0c\u5bf9\u5e94\u5916\u673a\u5347\u6863\u540e\u7684\u5b9e\u9645\u4ea4\u4ed8\u6548\u679c\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=448\" target=\"_blank\"><b>\u6210\u90fd\u548c\u8d35\u5357\u5c71\u4e0a 600\u33a1\u72ec\u680b\uff5c\u65e5\u7acb\u5c0a\u777f\u5168\u5c4b\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u51c0\u6052\u9759\u522b\u5885\u6848\u4f8b<\/b><span>\u4e1a\u4e3b 4 \u5e74\u5b9e\u6d4b\u590d\u76d8\uff1a\u6309\u5b9e\u9645\u9700\u6c42\u914d\u7f6e\u4f18\u4e8e\u5e02\u573a\u901a\u884c\u5927\u8d85\u914d\uff0c\u5185\u673a\u53ef\u4f18\u5316 5\u20136 \u53f0\u2014\u2014\u672c\u6848\u300c\u6309\u9700\u9009\u914d\u300d\u601d\u8def\u53ef\u5bf9\u7167\u53c2\u8003\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=6153\" target=\"_blank\"><b>\u6210\u90fd\u6b66\u4faf\u4e2d\u6d77\u4e5d\u53f7\u516c\u9986 200\u33a1\u4e09\u5b69\u5bb6\u5ead\uff5c\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b<\/b><span>\u65e5\u7acb\u591a\u5185\u673a\u9ad8\u540c\u5f00\u7387\u914d\u7f6e + \u7cbe\u5de5\u516d\u6b65\u6cd5\u4ea4\u4ed8\u6837\u672c\uff0c\u8fde\u63a5\u7387 111.6%\u2014\u2014\u540c\u54c1\u724c\u591a\u8054\u673a\u9009\u914d\u4e0e\u65bd\u5de5\u53ef\u53c2\u8003\u3002<\/span><\/a>\n    <\/div>\n    <p class=\"lm-note\">\ud83d\udccc \u4ee5\u4e0a\u4e3a\u9f99\u8109\u5df2\u4ea4\u4ed8\u7684\u771f\u5b9e\u6848\u4f8b\uff0c\u6237\u578b\u4e0e\u9762\u79ef\u5404\u4e0d\u76f8\u540c\uff0c\u4ec5\u4f5c\u914d\u7f6e\u601d\u8def\u4e0e\u5de5\u827a\u6807\u51c6\u7684\u53c2\u8003\uff0c\u4e0d\u4ee3\u8868\u672c\u6848\u6700\u7ec8\u6548\u679c\u627f\u8bfa\u3002<\/p>\n\n    <div class=\"lm-footnav\">\n      <a href=\"#s7\">[\u2191 \u672c\u8282\u9876\u90e8]<\/a>\n      <a href=\"#s7-case\">[7.1 \u76f8\u5173\u6848\u4f8b]<\/a>\n      <a href=\"#faq\">[FAQ \u2192]<\/a>\n    <\/div>\n  <\/section>\n\n  \n  <section class=\"lm-sec\" id=\"faq\">\n    <h2>\u2753 \u5e38\u89c1\u95ee\u9898\uff08FAQ\uff09<\/h2>\n    <div class=\"lm-card\">\n      <h4>Q1\uff1a\u4e09\u79cd\u914d\u7f6e\u7684\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f<\/h4>\n      <p>\u53ea\u5728<b>\u5ba2\u9910\u5385<\/b>\u3002\u5916\u673a\uff08RAS-125HRNAQ \/ RAS-140HRNAQ \u5355\u98ce\u6247\uff09\u3001\u4e3b\u5367 RPIZ-36FSNAQD\/P\u3001\u5367\u5ba4B RPIZ-22FSNAQD\/P\u3001\u5367\u5ba4C RPIZ-18FSNAQD\/P \u4e09\u79cd\u5b8c\u5168\u4e00\u81f4\u3002\u5dee\u522b\u662f\u5ba2\u9910\u5385\u653e RPIZ-71FSNAQD\/P\uff08A\uff09\u3001RPIZ-90FSNAQD\/P\uff08B\uff09\u8fd8\u662f RPIZ-71FSNAQD\/P + RPIZ-25FSNAQD\/P\uff08C\uff09\uff0c\u7531\u6b64\u5e26\u6765\u5185\u673a\u603b\u5bb9\u91cf 14.7 \/ 16.6 \/ 17.2 kW\uff0c\u5916\u673a A=RAS-125HRNAQ\u3001B\/C=RAS-140HRNAQ\uff0c\u8fde\u63a5\u7387 117.6% \/ 118.6% \/ 122.9% \u7684\u4e0d\u540c\u3002<\/p>\n\n      <h4>Q2\uff1a\u8fde\u63a5\u7387 B\u3001C \u90fd\u8d85\u4e86 130%\uff0c\u662f\u4e0d\u662f\u4e0d\u80fd\u7528\uff1f<\/h4>\n      <p>\u914d\u7f6e A \u7528 125 \u5355\u98ce\u6247\uff08117.6%\uff09\uff0c\u914d\u7f6e B \/ C \u76f4\u63a5\u91c7\u7528 140 \u5355\u98ce\u6247\uff08118.6% \/ 122.9%\uff09\uff0c<b>\u5747\u5df2\u843d\u5728\u6c1f\u7cfb\u7edf 50%\u2013130% \u89c4\u8303\u533a\u95f4\u5185<\/b>\u3002\u5176\u4e2d B \/ C \u82e5\u7528 125 \u4f1a\u8d85 130% \u7ea2\u7ebf\uff08132.8% \/ 137.6%\uff09\uff0c\u56e0\u6b64\u5916\u673a\u5b9a\u4e3a 140 \u5355\u98ce\u6247\u2014\u2014<b>\u5c3a\u5bf8\u4e0e 125 \u5b8c\u5168\u76f8\u540c\uff08770\u00d7980\u00d7360mm\uff09<\/b>\uff0c\u5347\u7ea7\u4e0d\u5360\u989d\u5916\u673a\u4f4d\uff0c\u5374\u628a\u8fde\u63a5\u7387\u62c9\u56de\u5408\u89c4\u3002<\/p>\n\n      <h4>Q3\uff1a125 \u548c 140 \u5355\u98ce\u6247\uff0c\u5c3a\u5bf8\u771f\u7684\u4e00\u6837\u5417\uff1f\u6362\u4e86\u4f1a\u4e0d\u4f1a\u653e\u4e0d\u4e0b\uff1f<\/h4>\n      <p><b>\u5b8c\u5168\u4e00\u6837\uff0c\u90fd\u662f 770\u00d7980\u00d7360mm\u3002<\/b>\u8fd9\u662f\u672c\u6b21\u65b9\u6848\u91cc\u6700\u5173\u952e\u7684\u4e00\u6761\uff1a\u60a8\u62c5\u5fc3\u673a\u4f4d\u653e\u4e0d\u4e0b\u624d\u6307\u5b9a\u5355\u98ce\u6247\uff0c\u800c\u5347\u5230 140 \u5e76\u4e0d\u9700\u8981\u591a\u5360\u4e00\u5bf8\u673a\u4f4d\uff0c\u566a\u97f3\u4e5f\u540c\u4e3a 54dB(A)\u3002\u5dee\u522b\u53ea\u6709\u5236\u51b7\u80fd\u529b\u4ece 12.5kW \u63d0\u5230 14.0kW\u3001APF \u4ece 5.90 \u5fae\u964d\u5230 5.80\u3001\u51c0\u91cd\u4ece 64kg \u5230 71kg\u3002<\/p>\n\n      <h4>Q4\uff1a\u5ba2\u9910\u5385 41.6\u33a1\uff0c\u5b98\u65b9\u9009\u578b\u53e3\u5f84 35\u201350\u33a1 \u6863\u4e3a\u4ec0\u4e48\u8bf4 63\/71 \u578b\u5c31\u591f\uff1f<\/h4>\n      <p>\u6309\u9f99\u8109\u5b98\u7f51\u8212\u4eab\u9009\u578b\u53e3\u5f84\uff1a25\u201335\u33a1\uff08\u5927\u5ba2\u5385\uff09\u5bf9\u5e94 63\/71\uff0c<b>35\u201350\u33a1\uff08\u5927\u5ba2\u5385\/\u9910\u5ba2\u4e00\u4f53\uff09\u540c\u6837\u843d\u5728 63\/71 \u6863\u5373\u53ef<\/b>\u3002\u60a8\u5bb6\u5ba2\u9910\u5385 41.6\u33a1 \u6309 150W\/\u33a1 \u5355\u5236\u51b7\u7b97\u7ea6 6.24kW\uff0c63 \u578b\u540d\u4e49 6.3kW \u521a\u597d\u8986\u76d6\u2014\u2014\u6240\u4ee5\u914d\u7f6e A \u7684 63 \u578b\u4ee5\u5355\u5236\u51b7\u5b9a\u4f4d\uff0c\u5bf9\u672c\u6237\u5ba2\u9910\u5385<b>\u5236\u51b7\u5b8c\u5168\u591f\u7528<\/b>\uff0c\u4e5f\u662f\u5b98\u65b9\u53e3\u5f84\u8ba4\u53ef\u7684\u914d\u7f6e\u3002B\/C \u628a\u5ba2\u9910\u5385\u5185\u673a\u505a\u5927\uff0871+25 \/ 90\uff09\uff0c\u4e3b\u8981\u662f\u8fdb\u4e00\u6b65<b>\u517c\u987e\u5236\u70ed\u3001\u5206\u533a\u6c14\u6d41\u4e0e\u5236\u51b7\u4f59\u91cf<\/b>\uff1b\u771f\u6b63\u8ba9 A \u4e0d\u5982 B\/C \u7684\uff0c\u662f<b>\u5236\u70ed<\/b>\u2014\u201463 \u578b\u4ee5\u5236\u51b7\u4e3a\u4e3b\uff0c\u51ac\u5929\u5ba2\u9910\u5385\u5236\u70ed\u4e0d\u7406\u60f3\uff0c\u4e3b\u8981\u9760\u5367\u5ba4\u7a7a\u8c03\u8865\u4f4d\u3002<\/p>\n\n      <h4>Q5\uff1a90 \u578b\u5185\u673a\u548c 63\/71 \u578b\uff0c\u540a\u9876\u4e0a\u5dee\u591a\u5c11\uff1f<\/h4>\n      <p>\u5dee\u522b\u4e0d\u5c0f\u300263\/71 \u578b\u662f <b>192\u00d71180\u00d7447mm<\/b>\uff08\u9ad8\u00d7\u5bbd\u00d7\u6df1\uff09\uff0c90 \u578b\u662f <b>218\u00d7(1480+82)\u00d7615mm<\/b>\u2014\u2014<b>\u9ad8 26mm\u3001\u5bbd\u7ea6 380mm\u3001\u8fdb\u6df1\u591a 168mm<\/b>\u3002\u4e5f\u5c31\u662f\u8bf4\uff0c\u7528 90 \u578b\u5ba2\u9910\u5385\u540a\u9876\u8981\u6bd4\u7528 63\/71 \u578b<b>\u591a\u7559 168mm \u8fdb\u6df1<\/b>\u3002\u60a8\u8ffd\u6c42\u7f8e\u89c2\u3001\u4e0d\u60f3\u538b\u5c42\u9ad8\uff0c\u8fd9\u4e00\u70b9\u5fc5\u987b\u63d0\u524d\u548c\u6728\u5de5\u4ea4\u5e95\u3002<\/p>\n\n      <h4>Q6\uff1a\u53ea\u505a\u7a7a\u8c03\u4e0d\u505a\u5730\u6696\uff0c\u51ac\u5929\u5367\u5ba4\u9760\u7a7a\u8c03\u5236\u70ed\u591f\u5417\uff1f<\/h4>\n      <p>\u4e09\u4e2a\u5367\u5ba4\u662f<b>\u6309\u5236\u70ed 220W\/\u33a1 \u53e3\u5f84<\/b>\u9009\u7684\u673a\uff0c\u4e0d\u662f\u53ea\u6309\u5236\u51b7\u9009\uff1a\u4e3b\u5367 15.4\u33a1 \u9700 3.39kW \u2192 36 \u578b\u5236\u70ed 4.0kW\uff1b\u5367\u5ba4B \u9700 2.29kW \u2192 22 \u578b\u5236\u70ed 2.5kW\uff1b\u5367\u5ba4C \u9700 1.85kW \u2192 18 \u578b\u5236\u70ed 2.2kW\uff0c\u4e09\u95f4\u90fd\u6709\u4f59\u91cf\u3002\u9700\u8981\u8bf4\u660e\u7684\u662f\uff0c\u7a7a\u8c03\u5236\u70ed\u662f<b>\u70ed\u98ce\u81ea\u4e0a\u800c\u4e0b<\/b>\uff0c\u811a\u611f\u4e0d\u5982\u5730\u6696\uff1b\u6210\u90fd\u51ac\u5b63\u6c14\u6e29\u4e0d\u7b97\u6781\u7aef\uff0c\u4e24\u53e3\u5b50\u5e38\u4f4f\u8db3\u591f\uff0c\u4f46\u5982\u679c\u60a8\u7279\u522b\u5728\u610f\"\u811a\u6696\"\uff0c\u540e\u671f\u53ef\u518d\u8bc4\u4f30\u3002<\/p>\n\n      <h4>Q7\uff1a\u600e\u4e48\u4fdd\u8bc1\u8f85\u6750\u4e0d\u88ab\u5077\u5de5\u51cf\u6599\uff1f<\/h4>\n      <p>\u8fdb\u573a\u540e\u6309 3.5 \u8282\u8f85\u6750\u6e05\u5355\u9010\u9879\u5bf9\u7167\uff0c\u9690\u853d\u9879\u7531\u9f99\u8109\u76d1\u7406\u9a8c\u6536\u7559\u6863\u3001\u968f\u65f6\u53ef\u8c03\u9605\u3002<\/p>\n\n      <h4>Q8\uff1a\u8fd9\u4e2a\u65b9\u6848\u4e66\u4e3a\u4ec0\u4e48\u6ca1\u6709\u62a5\u4ef7\uff1f<\/h4>\n      <p>\u672c\u9875\u5b9a\u4f4d\u662f<b>\u6280\u672f\u6807\uff0c\u4e0d\u662f\u4ef7\u683c\u6807<\/b>\u2014\u2014\u76ee\u7684\u662f\u8ba9\u60a8\u805a\u7126\"\u54ea\u79cd\u914d\u7f6e\u66f4\u9002\u914d\u6211\u5bb6\"\uff0c\u800c\u4e0d\u662f\u505a\u4e00\u6b21\u6027\u5c01\u6807\u6bd4\u4ef7\u3002\u5916\u9762\u7684\u4f4e\u4ef7\u62a5\u4ef7\u5e38\u5e38\u5148\u538b\u4ef7\u3001\u518d\u9760\u8f85\u6750\u964d\u6807\u6216\u589e\u9879\u627e\u8865\u3002\u914d\u7f6e\u3001\u53c2\u6570\u3001\u6750\u6599\u6e05\u5355\u90fd\u662f\u53ef\u6838\u9a8c\u7684\u786c\u5185\u5bb9\uff1b\u4ef7\u683c\u4e0e\u5f53\u671f\u6d3b\u52a8\u4f18\u60e0\u3001\u5382\u5bb6\u8865\u8d34\u9700\u5728\u7ebf\u4e0b\u6c9f\u901a\u65f6\u9010\u9879\u786e\u8ba4\u3002<\/p>\n    <\/div>\n  <\/section>\n\n  \n  <section class=\"lm-sec\" id=\"more\">\n    <h2>\ud83d\udd17 \u4e86\u89e3\u66f4\u591a\uff08\u4ea7\u54c1 \/ \u6848\u4f8b \/ \u95e8\u5e97 \/ \u670d\u52a1\u4fdd\u969c\uff09<\/h2>\n    <div class=\"lm-links\">\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\"><b>\u65e5\u7acb\u8212\u4eab \u00b7 \u5b8c\u6574\u4ea7\u54c1\u624b\u518c<\/b><span>\u8212\u4eab\u5355\u98ce\u6247\u5168\u6863\u4f4d\u53c2\u6570\u3001\u5185\u673a\u9009\u578b\u53e3\u5f84\u3001\u7ebf\u63a7\u5668\u4e0e\u51c0\u5316\u6a21\u5757\u9009\u914d\u8bf4\u660e\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=611\" target=\"_blank\"><b>\u9f99\u8109\u7cbe\u5de5\u516d\u6b65\u6cd5<\/b><span>\u52d8\u6d4b\u2192\u8bbe\u8ba1\u2192\u65bd\u5de5\u2192\u6253\u538b\u2192\u8c03\u8bd5\u2192\u5efa\u6863\u7684\u5b8c\u6574\u4ea4\u4ed8\u6807\u51c6\u4e0e\u62cd\u7167\u7559\u6863\u8981\u6c42\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\"><b>\u670d\u52a1\u4fdd\u969c\u4e0e\u8d28\u4fdd\u8fb9\u754c<\/b><span>\u8bbe\u5907 10 \u5e74 + \u5b89\u88c5 10 \u5e74\uff08\u5382\u5bb6\u515c\u5e95\uff09\u7684\u627f\u4fdd\u8303\u56f4\u3001\u54cd\u5e94\u65f6\u6548\u4e0e\u56de\u8bbf\u673a\u5236\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><b>\u6848\u4f8b\u4e2d\u5fc3\u805a\u5408\u9875<\/b><span>\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b\uff0c\u6309\u54c1\u724c\/\u6237\u578b\/\u533a\u57df\u68c0\u7d22\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10636\" target=\"_blank\"><b>\u4e1c\u539f\u4eb2\u4eb2\u91cc 80\u33a1\uff5c\u8212\u4eab 125 \u4e00\u62d6\u56db<\/b><span>\u4e0e\u672c\u6848\u540c\u5916\u673a\u6863\u3001\u540c\u4e3a\u4e00\u62d6\u56db\u7684\u5c0f\u9762\u79ef\u5e73\u5c42\u5b8c\u5de5\u5b9e\u666f\u3002<\/span><\/a>\n      <a class=\"lm-link\" href=\"https:\/\/longmai-nt.com\/?page_id=10955\" target=\"_blank\"><b>\u76db\u548c\u6797\u8bed\uff5c\u8212\u4eab\u5355\u98ce\u6247\u62d6\u4e94<\/b><span>\u5355\u98ce\u6247\u5916\u673a\u7684\u771f\u5b9e\u673a\u4f4d\u5b89\u88c5\u6848\u4f8b\uff0c\u5bf9\u5e94\u60a8\"\u653e\u5f97\u4e0b\"\u7684\u6838\u5fc3\u987e\u8651\u3002<\/span><\/a>\n    <\/div>\n  <\/section>\n\n  \n  <div class=\"lm-cta\" id=\"contact\">\n    <h3>\ud83d\udcde \u9884\u7ea6\u52d8\u6d4b \u00b7 \u9501\u5b9a\u60a8\u7684\u65b9\u6848<\/h3>\n    <div class=\"lm-phones\">\n      <a href=\"tel:02886131795\">028-86131795<\/a> \uff5c <a href=\"tel:02865272586\">028-65272586<\/a>\n    <\/div>\n    <div class=\"lm-promise\">\n      <span>\u2713 \u65e5\u7acb\u6210\u90fd\u76f4\u8425<\/span>\n      <span>\u2713 \u539f\u5382\u5185\u673a<\/span>\n      <span>\u2713 \u94dc\u7ba1\u58c1\u539a\u660e\u793a\u53ef\u6838\u9a8c<\/span>\n      <span>\u2713 \u8bbe\u590710\u5e74+\u5b89\u88c510\u5e74<\/span>\n      <span>\u2713 \u81ea\u6709\u5b89\u88c5\u56e2\u961f<\/span>\n      <span>\u2713 \u6280\u672f\u6807\u4e0d\u542b\u5c01\u6807\u62a5\u4ef7<\/span>\n    <\/div>\n    <div class=\"lm-stores\">\n      <div class=\"lm-store\">\n        <div class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\"><\/div>\n        <b>\u5357\u5bcc\u68ee\u95e8\u5e97<\/b>\n        <a href=\"tel:02886131795\">028-86131795<\/a>\n        <a class=\"lm-amap\" href=\"https:\/\/www.amap.com\/place\/B0FFKQ3088\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;margin-top:6px;font-size:12px;color:#fff;text-decoration:none;border:1px solid rgba(255,255,255,.6);border-radius:16px;padding:2px 9px;\">\ud83d\udccd \u9ad8\u5fb7\u5730\u56fe<\/a>\n      <\/div>\n      <div class=\"lm-store\">\n        <div class=\"lm-photo\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\"><\/div>\n        <b>\u5317\u5bcc\u68ee\u95e8\u5e97<\/b>\n        <a href=\"tel:02865272586\">028-65272586<\/a>\n        <a class=\"lm-amap\" href=\"https:\/\/www.amap.com\/place\/B0G12NIKK5\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;margin-top:6px;font-size:12px;color:#fff;text-decoration:none;border:1px solid rgba(255,255,255,.6);border-radius:16px;padding:2px 9px;\">\ud83d\udccd \u9ad8\u5fb7\u5730\u56fe<\/a>\n      <\/div>\n    <\/div>\n    <div class=\"lm-svc\">\u987e\u95ee\uff1a<b>\u5f90\u65b0\u5e73<\/b>\uff08\u5317\u5bcc\u68ee\uff09\u00b7 \u9f99\u8109\u6696\u901a\uff08\u65e5\u7acb\u6210\u90fd\u76f4\u8425\u6388\u6743\u7ecf\u9500\u5546\uff09\uff5c <a href=\"https:\/\/longmai-nt.com\">longmai-nt.com<\/a> \uff5c \u552e\u540e\u4e13\u7ebf <a href=\"tel:02861649321\">028-61649321<\/a><\/div>\n    <a class=\"lm-btn\" href=\"tel:02865272586\">\u7acb\u5373\u9884\u7ea6\u52d8\u6d4b<\/a>\n  <\/div>\n\n  <div class=\"lm-foot\">\n    \u9f99\u8109\u6696\u901a \u00a9 2026<br>\n    \u672c\u9875\u4e3a\u6280\u672f\u53c2\u8003\u65b9\u6848\uff0c<b>\u4e0d\u542b\u62a5\u4ef7<\/b>\u3002\u53c2\u6570\u4ee5\u5382\u5bb6\u968f\u673a\u94ed\u724c\u4e0e\u300a\u8bbe\u8ba1\u6280\u672f\u624b\u518c\u300b\u4e3a\u51c6\u3002<br>\n    \u65bd\u5de5\u5b9e\u666f\u56fe\u6807\u6ce8\"\u975e\u672c\u6848\u5b9e\u62cd\"\u8005\u5747\u4e3a\u672c\u54c1\u724c\u5176\u4ed6\u5df2\u4ea4\u4ed8\u5de5\u5730\u793a\u4f8b\uff1b\u672c\u6848\u8fdb\u573a\u540e\u7531\u9f99\u8109\u81ea\u6709\u56e2\u961f\u5b9e\u62cd\u5f52\u6863\u66ff\u6362\u3002\u6700\u7ec8\u914d\u7f6e\u4ee5\u73b0\u573a\u590d\u5c3a\u4e0e\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\u3002\n  <\/div>\n\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7  [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-13223","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=13223\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=13223\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-14T03:33:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhhy-hls-ktxtsjt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"12 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223\",\"name\":\"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \\\/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/lhhy-hls-ktxtsjt.jpg\",\"datePublished\":\"2026-09-27T05:07:24+00:00\",\"dateModified\":\"2026-10-14T03:33:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/lhhy-hls-ktxtsjt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/lhhy-hls-ktxtsjt.jpg\",\"width\":1187,\"height\":890},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13223#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \\\/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=13223","og_locale":"zh_CN","og_type":"article","og_title":"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","og_description":"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=13223","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-14T03:33:13+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhhy-hls-ktxtsjt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"12 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=13223","url":"https:\/\/longmai-nt.com\/?page_id=13223","name":"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=13223#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=13223#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhhy-hls-ktxtsjt.jpg","datePublished":"2026-09-27T05:07:24+00:00","dateModified":"2026-10-14T03:33:13+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=13223#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=13223"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=13223#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhhy-hls-ktxtsjt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/lhhy-hls-ktxtsjt.jpg","width":1187,"height":890},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=13223#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5468\u54e5 \u00b7 \u4e2d\u592e\u7a7a\u8c03\uff08\u65e5\u7acb\u8212\u4eab\u5355\u98ce\u6247 \u00b7 125 \/ 140\uff09\u4e09\u914d\u7f6e\u6280\u672f\u65b9\u6848\u5bf9\u6bd4"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13223"}],"version-history":[{"count":10,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13223\/revisions"}],"predecessor-version":[{"id":14886,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/13223\/revisions\/14886"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}