{"id":1327,"date":"2026-05-30T15:31:44","date_gmt":"2026-05-30T07:31:44","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1327"},"modified":"2026-06-05T10:38:00","modified_gmt":"2026-06-05T02:38:00","slug":"%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a%c2%b7%e4%bf%9d%e5%88%a9%e5%a4%a9%e7%8e%ba%e5%91%a8%e8%80%81%e5%b8%88%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e6%a1%a3%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1327","title":{"rendered":"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u5468\u8001\u5e08<br><strong>\u9879\u76ee<\/strong>\u5730\u5740\uff1a\u4fdd\u5229\u5929\u73ba\uff0c\u91c7\u6696\u9762\u79ef\u7ea6170\u33a1<br><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u9ec4\u52c7<br><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670825\u65e5<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u76ee\u5f55<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u7b2c\u4e00\u9636\u6bb5\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/h3>\n\n\n\n<h3 id=\"bltx01\" class=\"wp-block-heading has-medium-font-size\"><a href=\"#bltx01\">1\u3001\u65b9\u6848\u5185\u5bb9<\/a><\/h3>\n\n\n\n<h3 id=\"bltx02\" class=\"wp-block-heading has-medium-font-size\"><a href=\"#bltx02\">2\u3001\u9700\u6c42\u4e0e\u75db\u70b9<\/a><\/h3>\n\n\n\n<h4 id=\"bltx03\" class=\"wp-block-heading\"><a href=\"#bltx03\">3\u3001\u8bbe\u8ba1\u7406\u5ff5<\/a><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx04\">4\u3001\u8bbe\u8ba1\u4f9d\u636e<\/a><\/h4>\n\n\n\n<h4 id=\"bltx05\" class=\"wp-block-heading\"><a href=\"#bltx05\">5\u3001\u914d\u7f6e\u65b9\u6848<\/a><\/h4>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><a href=\"#bltx06\">6\u3001\u62a5\u4ef7\u6e05\u5355<\/a><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx07\">7\u300110\u5e74\u4fdd\u969c\u8ba1\u5212<\/a><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx08\">8\u3001\u670d\u52a1\u627f\u8bfa<\/a><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx09\">9\u3001\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c<\/a><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx10\">10\u3001\u6743\u5a01\u80cc\u4e66\u9875<\/a><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx11\">11\u3001\u5b89\u88c5\u4e0e\u552e\u540e\u4fdd\u969c<\/a><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><a href=\"#bltx12\">12\u3001\u5408\u540c<\/a><\/h4>\n\n\n\n<h2 id=\"bltx01\" class=\"wp-block-heading has-medium-font-size\">\u3010\u7b2c1\u9879\uff1a\u65b9\u6848\u5185\u5bb9\u3011<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee\u540d\u79f0<\/strong>\uff1a\u4e09\u5c42\u522b\u5885\u8212\u9002\u5bb6\u5c45\u7cfb\u7edf\u65b9\u6848<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u5185\u5bb9<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf\uff08\u5206\u533a\u72ec\u7acb\u63a7\u5236\uff09<\/li>\n\n\n\n<li>\u5168\u5c4b\u5730\u6696\u7cfb\u7edf + <strong>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/strong><\/li>\n\n\n\n<li>\u70ed\u6c34\u7cfb\u7edf\u4f18\u5316<\/li>\n\n\n\n<li>\u65b0\u98ce\u7cfb\u7edf\uff08\u52d8\u5bdf\u540e\u786e\u5b9a\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u9ec4\u52c7 | <strong>\u8054\u7cfb\u7535\u8bdd<\/strong>\uff1a[15828489188]<\/p>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 id=\"bltx02\" class=\"wp-block-accordion-heading has-medium-font-size\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u3010\u7b2c2\u9879\uff1a\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9\u3011<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-1\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u8bf4\u7684\/\u60a8\u7684\u60c5\u51b5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7406\u89e3\u7684<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u4e0d\u8981\u4e00\u505c\u4e00\u644a\u3001\u4e00\u505c\u4e00\u644a\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u60a8\u62c5\u5fc3\u7684\u662f\u7a7a\u8c03\u9891\u7e41\u542f\u505c\u5bfc\u81f4\u6e29\u5ea6\u5ffd\u51b7\u5ffd\u70ed\u2014\u2014\u4e0d\u662f\u201c\u5236\u51b7\u4e0d\u591f\u201d\uff0c\u662f\u201c\u63a7\u5236\u4e0d\u7cbe\u201d\u3002\u65e5\u7acb\u5230\u8fbe\u6e29\u5ea6\u540e\u4ee510%\u529f\u7387\u6301\u7eed\u8fd0\u884c\uff0c\u4e0d\u505c\u673a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e09\u5c42\u697c\uff0c\u65e0\u5730\u6696\uff0c\u7a7a\u8c03\u517c\u987e\u5236\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u60a8\u62c5\u5fc3\u51ac\u5929\u5ba2\u5385\u70ed\u98ce\u5439\u4e0d\u5230\u811a\u3002\u4e2d\u592e\u7a7a\u8c03\u5236\u70ed\u786e\u5b9e\u5b58\u5728\u201c\u70ed\u7a7a\u6c14\u4e0a\u6d6e\u201d\u7684\u7269\u7406\u7279\u6027\uff0c\u8fd9\u4e5f\u662f\u4e3a\u4ec0\u4e48\u60a8\u6700\u7ec8\u51b3\u5b9a\u589e\u52a0\u5168\u5c4b\u5730\u6696\u2014\u2014\u8fd9\u662f\u6b63\u786e\u7684\u51b3\u7b56<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u4e24\u4e2a\u513f\u5b50\u540c\u65f6\u6d17\u6fa1\uff0c\u70ed\u6c34\u4e0d\u591f\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u60a8\u62c5\u5fc3\u7684\u662f\u51ac\u5b63\u8fdb\u6c34\u6e29\u5ea6\u4f4e\u65f6\uff0c\u5355\u53f0\u70ed\u6c34\u5668\u6d41\u91cf\u4e0d\u8db3\u3002\u5206\u4e24\u53f016L\u72ec\u7acb\u4f9b\u5e94\u4e0d\u540c\u697c\u5c42\uff0c\u6bd4\u5355\u53f024L\u66f4\u53ef\u9760\u3001\u66f4\u7701\u94b1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e0c\u671b\u4fdd\u7559\u65e7\u65b0\u98ce\u8bbe\u5907<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u60a8\u5e0c\u671b\u5229\u7528\u73b0\u6709\u8d44\u6e90\uff0c\u4e0d\u6d6a\u8d39\u3002\u6211\u4eec\u4f1a\u4e0a\u95e8\u52d8\u5bdf\uff0c\u5982\u53ef\u7528\u5219\u4fdd\u7559\uff0c\u4e0d\u53ef\u7528\u5219\u63a8\u8350\u5168\u70ed\u4ea4\u6362\u65b0\u98ce<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u516510\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u60a8\u5173\u5fc3\u7684\u4e0d\u662f\u201c\u88c5\u5b8c\u90a3\u4e00\u523b\u201d\uff0c\u800c\u662f\u201c\u672a\u676510\u5e74\u7528\u5f97\u8d77\u3001\u7528\u5f97\u7a33\u201d\u2014\u2014\u8fd9\u6b63\u662f\u6211\u4eec\u8ba1\u5212\u7684\u627f\u8bfa<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 id=\"bltx03\" class=\"wp-block-accordion-heading has-medium-font-size\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\" style=\"padding-top:0;padding-bottom:0\"><span class=\"wp-block-accordion-heading__toggle-title\">\u3010\u7b2c3\u9879\uff1a\u6211\u4eec\u8bbe\u8ba1\u7406\u5ff5\u3011<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-2\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<h4 class=\"wp-block-heading\">\u6838\u5fc3\u8bbe\u8ba1\u7406\u5ff5<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u539f\u5219<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7cfb\u7edf\u601d\u7ef4<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u5957\u597d\u7684\u7cfb\u7edf\uff0c\u4e0d\u662f\u67d0\u4e2a\u8bbe\u5907\u6709\u591a\u597d\uff0c\u800c\u662f\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u4e2a\u73af\u8282\u534f\u540c\u5de5\u4f5c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5ba2\u6237\u6210\u529f\u5bfc\u5411<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6309\u60a8\u7684\u771f\u5b9e\u4f7f\u7528\u4e60\u60ef\uff08\u5206\u533a\u4f7f\u7528\u3001\u5206\u6279\u5f00\u542f\uff09\u6765\u914d\u7f6e\uff0c\u4e0d\u6309\u201c\u603b\u5185\u673a\u53f0\u6570\u201d\u76f2\u76ee\u52a0\u5927\u5916\u673a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u957f\u671f\u4ef7\u503c\u5bfc\u5411<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u60a8\u5df2\u52a0\u516510\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff0c\u6211\u4eec\u5173\u6ce8\u7684\u4e0d\u53ea\u662f\u521d\u6295\u8d44\uff0c\u800c\u662f20\u5e74\u603b\u8d26\u548c\u957f\u671f\u4f7f\u7528\u7a33\u5b9a\u6027<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9488\u5bf9\u60a8\u5bb6170\u33a1\u5730\u6696\u7684\u6838\u5fc3\u8bbe\u8ba1\u903b\u8f91<\/strong>\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u51b3\u7b56<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e3a\u4ec0\u4e48\u8fd9\u4e48\u505a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u60a8\u7684\u4ef7\u503c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089 + \u4e8c\u6b21\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u5728\u4f4e\u6e29\u4f9b\u6c34\u4e0b\u6548\u7387\u6700\u9ad8\uff08\u7701\u6c14\uff09\uff1b\u4e8c\u6b21\u7cfb\u7edf\u786e\u4fdd170\u33a1\u5927\u5b85\u6c34\u529b\u5e73\u8861\u3001\u5404\u623f\u95f4\u6e29\u5ea6\u5747\u5300<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7701\u6c14 + \u4e0d\u5ffd\u51b7\u5ffd\u70ed<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De32\u4e3b\u7ba1 + De20\u76d8\u7ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u7ba1\u6d41\u91cf\u5145\u8db3\uff0c\u8fdc\u7aef\u623f\u95f4\u4e5f\u80fd\u70ed\u5f97\u8d77\u6765<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u5c4b\u6e29\u5ea6\u5747\u5300<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5ba4\u6e29\u8fbe\u6807\u540e\u9505\u7089\u81ea\u52a8\u505c\u673a\uff0c\u675c\u7edd\u65e0\u6548\u4ea7\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u6708\u7701\u6c1410-25%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u62a5\u544a\uff0c\u4e0e\u540c\u6237\u578b\u5bf9\u6807\uff0c\u4e3b\u52a8\u4f18\u5316<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7528\u5f97\u8d77\u3001\u7528\u5f97\u660e\u767d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-3&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 id=\"bltx04\" class=\"wp-block-accordion-heading has-medium-font-size\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-3-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-3\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u3010\u7b2c4\u9879\uff1a\u8bbe\u8ba1\u4f9d\u636e\u3011<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-3\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-3-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">GB 50736-2012<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">JGJ 142-2012<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">GB 20665-2015<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5bb6\u7528\u71c3\u6c14\u5feb\u901f\u70ed\u6c34\u5668\u548c\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u80fd\u6548\u9650\u5b9a\u503c\u53ca\u80fd\u6548\u7b49\u7ea7<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 id=\"bltx05\" class=\"wp-block-heading has-medium-font-size\">\u3010\u7b2c5\u9879\uff1a\u914d\u7f6e\u65b9\u6848\u3011<\/h2>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">5.1 \u4e2d\u592e\u7a7a\u8c03\uff08\u5206\u533a\u72ec\u7acb\u63a7\u5236\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5916\u673a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u914d\u7f6e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e00<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d1f\u4e00\u697c\u5f71\u97f3\u5ba4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u7ba1\u673a\uff082\u5339\u5e26\u6cf5\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e0\u6392\u6c34\uff0c\u5e26\u63d0\u5347\u6cf5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e8c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8212\u4eab RAS-125HRNAQ<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.3+6.3+2.5kW\uff083\u53f0\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u9910\u5385+\u4e66\u623f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1077#swjxj\">\u8212\u4eab RAS-1<\/a><a href=\"https:\/\/longmai-nt.com\/?page_id=1077#swjx\">40HRNAQ<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">6.3+4.0+3.2kW\uff083\u53f0\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e09\u95f4\u5367\u5ba4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5408\u8ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e09\u5c42\u697c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3\u5957\u72ec\u7acb\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>7\u53f0\u5185\u673a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u533a\u4f7f\u7528\uff0c\u4e92\u4e0d\u5e72\u6270<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-4 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1706\" height=\"1279\" data-id=\"1161\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1.jpg\" alt=\"\" class=\"wp-image-1161\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1.jpg 1706w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-1-1536x1152.jpg 1536w\" sizes=\"auto, (max-width: 1706px) 100vw, 1706px\" \/><\/figure>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-5 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1706\" height=\"1279\" data-id=\"1162\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2.jpg\" alt=\"\" class=\"wp-image-1162\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2.jpg 1706w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acb\u8212\u4eab\u5916\u673a-2-1536x1152.jpg 1536w\" sizes=\"auto, (max-width: 1706px) 100vw, 1706px\" \/><\/figure>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-6 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"460\" height=\"336\" data-id=\"1112\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acbWiFi\u7ebf\u63a7\u5668.jpg\" alt=\"\" class=\"wp-image-1112\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acbWiFi\u7ebf\u63a7\u5668.jpg 460w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/\u65e5\u7acbWiFi\u7ebf\u63a7\u5668-300x219.jpg 300w\" sizes=\"auto, (max-width: 460px) 100vw, 460px\" \/><figcaption class=\"wp-element-caption\">\u65e5\u7acbWiFi\u7ebf\u63a7\u5668<\/figcaption><\/figure>\n<\/figure>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">5.2 \u5730\u6696\u7cfb\u7edf\uff08\u5168\u5c4b\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\u5c0f\u536124KW\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u51b7\u51dd\uff0c\u70ed\u6548\u7387108%\uff0c\u6700\u5c0f\u8f93\u51fa3-4kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u5f62\u5f0f<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e8c\u6b21\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u8bc1170\u33a1\u5927\u5b85\u6c34\u529b\u5e73\u8861\uff0c\u5404\u623f\u95f4\u6e29\u5ea6\u5747\u5300<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u7ba1\u7ba1\u5f84<\/td><td class=\"has-text-align-left\" data-align=\"left\">De32<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d41\u91cf\u5145\u8db3\uff0c\u4fdd\u969c\u8fdc\u7aef\u623f\u95f4\u70ed\u91cf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u76d8\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f1f\u661fPE-RT\u963b\u6c27\u7ba1 De20<\/td><td class=\"has-text-align-left\" data-align=\"left\">5\u5c42\u963b\u6c27\uff0c\u8d28\u4fdd50\u5e74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e03\u7ba1\u65b9\u5f0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ae0\u9c7c\u5f0f\uff08\u5206\u96c6\u6c34\u5668\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u8def\u72ec\u7acb\u63a7\u5236\uff0c\u675c\u7edd\u201c\u8fd1\u70ed\u8fdc\u51b7\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u6e29\u5c42<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f1f\u661f\u767d\u6676\u677f2cm + \u7eaf\u94dd\u53cd\u5c04\u819c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51cf\u5c11\u5411\u4e0b\u70ed\u635f\u5931<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fbe\u6807\u81ea\u52a8\u505c\u7089\uff0c\u7701\u6c1410-25%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-7 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" data-id=\"1744\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg\" alt=\"\" class=\"wp-image-1744\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg 800w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786-300x300.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786-150x150.jpg 150w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5982\u60f3\u8be6\u7ec6\u4e86\u89e3<a href=\"https:\/\/longmai-nt.com\/?page_id=1841\">\u66fc\u745e\u5fb7\u4ea7\u54c1\u8bf7\u70b9\u51fb\u2192<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">5.3\u9879\uff1a\u8d85\u914d\u7387\u6838\u7b97\u4e0e\u914d\u7f6e\u5408\u7406\u6027\u5206\u6790<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u8c03\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u662f\u5426\u5408\u7406<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u673a\u529f\u7387\u4e0e\u672b\u7aef\u5339\u914d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u533a\u72ec\u7acb\u7cfb\u7edf\uff0c\u5206\u6279\u4f7f\u7528<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u6700\u5c0f\u8f93\u51fa3-4kW\u5339\u914d170\u33a1\u6052\u6e29\u8d1f\u8377\uff08\u7ea68-10kW\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u5408\u7406<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u662f\u5426\u5b58\u5728\u201c\u4e60\u60ef\u6027\u8d85\u914d\u201d\uff1f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6309\u5b9e\u9645\u623f\u95f4\u6570\u914d\u7f6e\uff0c\u65e0\u5197\u4f59<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6309170\u33a1\u8bbe\u8ba1\u8d1f\u8377\u914d\u7f6e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u5408\u7406<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u53f0\u6570\u662f\u5426\u5b58\u5728\u5197\u4f59\uff1f<\/td><td class=\"has-text-align-left\" data-align=\"left\">7\u53f0\u5bf9\u5e947\u4e2a\u533a\u57df<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u5408\u7406<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u4f4e\u6e29\u4f9b\u6c34\u65f6\u672b\u7aef\u6563\u70ed\u80fd\u529b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">De32\u4e3b\u7ba1+De20\u76d8\u7ba1\uff0c\u6563\u70ed\u91cf\u2265170\u33a1\u70ed\u8d1f\u8377<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u5408\u7406<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 id=\"bltx06\" class=\"wp-block-heading has-medium-font-size\">\u3010\u7b2c6\u9879\uff1a\u62a5\u4ef7\u6e05\u5355\u3011<\/h2>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">6.1 \u4e2d\u592e\u7a7a\u8c03\uff08\u5206\u533a\u72ec\u7acb\u63a7\u5236\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5916\u673a\/\u5185\u673a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7\uff08\u5143\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1\uff08\u5143\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e00<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d1f\u4e00\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u7ba1\u673a\uff082\u5339\u5e26\u6cf5\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">RAS-50X1DQ1\/P<\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">6,050<\/td><td class=\"has-text-align-left\" data-align=\"left\">6,050<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e8c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5916\u673a\uff08\u8212\u4eab\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">RAS-125HRNBQ<\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e8c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u00d73<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.3+6.3+2.5kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">3\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">23,793<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5916\u673a\uff08\u8212\u4eab\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">RAS-140HRNBQ<\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4e09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u697c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u00d73<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.3+4.0+3.2kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">3\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">24,610<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u8c03\u5408\u8ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>7\u53f0\u5185\u673a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>54,453<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">6.2 \u5730\u6696\u7cfb\u7edf\uff08\u5168\u5c4b170\u33a1\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\/\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7\uff08\u5143\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1\uff08\u5143\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\u5c0f\u536124KW\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">10,900<\/td><td class=\"has-text-align-left\" data-align=\"left\">10,900<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u7cfb\u7edf\uff08\u542b\u8054\u52a8\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9f99\u8109\u8282\u80fd\u5b9a\u5236\uff08179\u5143\/\u33a1\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">170\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">179<\/td><td class=\"has-text-align-left\" data-align=\"left\">30,430<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5730\u6696\u5408\u8ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>41,330<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">6.3 \u8d39\u7528\u6c47\u603b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">54,453<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u7cfb\u7edf\uff08\u542b\u9505\u7089\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">41,330<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">8,000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u65b0\u98ce\u7cfb\u7edf\uff08\u9884\u4f30\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">0-16,000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8bbe\u5907\u53ca\u5b89\u88c5\u5408\u8ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ea6103,783-119,783<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f1a\u5458\u6696\u901a\u62b5\u6263\u91d1<\/td><td class=\"has-text-align-left\" data-align=\"left\">-1,000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9884\u4f30\u843d\u5730\u4ef7<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ea6102,783-118,783<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc \u7cbe\u786e\u62a5\u4ef7\u9700\u5728\u7cbe\u786e\u9762\u79ef\u548c\u65b0\u98ce\u52d8\u5bdf\u540e\u786e\u5b9a\u3002\u56fd\u8865\u5ba2\u6237\u53ef\u81ea\u884c\u9886\u5238\uff0c\u7ea61,500\u5143\/\u5957\uff0c\u53ef\u4e0e\u4f1a\u5458\u62b5\u6263\u53e0\u52a0\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 id=\"bltx07\" class=\"wp-block-heading has-medium-font-size\">\u3010\u7b2c7\u9879\uff1a10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u8bf4\u660e\u3011<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u5df2\u52a0\u5165\u9f99\u8109\u6696\u901a\u201c10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u201d\u3002\u8fd9\u4e0d\u662f\u8425\u9500\u6d3b\u52a8\uff0c\u662f\u5199\u8fdb\u60a8\u5ba2\u6237\u6863\u6848\u768410\u5e74\u670d\u52a1\u627f\u8bfa\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">7.1 \u5206\u7ec4\u8bf4\u660e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ec4\u522b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u8c01<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u60a8\u7684\u65b9\u6848\u5bf9\u5e94<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>A\u7ec4\uff08\u5bf9\u7167\u7ec4\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u81ea\u5df1\u7684\u60f3\u6cd5\uff0c\u90e8\u5206\u8ba4\u53ef\u6211\u4eec\u7684\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>B\u7ec4\uff08\u5b9e\u9a8c\u7ec4\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u5168\u8ba4\u53ef\u6211\u4eec\u7684\u7cfb\u7edf\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 <strong>\u60a8\u5c5e\u4e8eB\u7ec4<\/strong>\uff08\u5b8c\u5168\u6309\u6211\u4eec\u63a8\u8350\u65b9\u6848\u6267\u884c\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">7.2 B\u7ec4\u4e13\u5c5e\u6743\u76ca<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u76ca<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u514d\u8d39\u8054\u52a8\u63a7\u5236\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8\uff0c\u5df2\u5305\u542b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u91c7\u6696\u5b63\u7ed3\u675f\u540e\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u6237\u578b\u8131\u654f\u5bf9\u6807<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u6211\u5bb6\u8fd9\u4e2a\u80fd\u8017\uff0c\u7b97\u9ad8\u8fd8\u662f\u7b97\u4f4e\uff1f\u201d\u2014\u2014\u63d0\u4f9b\u540c\u6237\u578b\u5bf9\u6bd4\u6570\u636e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4f18\u5316\u5efa\u8bae<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6570\u636e\u663e\u793a\u6709\u4f18\u5316\u7a7a\u95f4\u65f6\uff0c\u4e3b\u52a8\u7ed9\u51fa\u5efa\u8bae<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e74\u5ea6\u56de\u8bbf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u91c7\u6696\u5b63\u4e3b\u52a8\u56de\u8bbf\u7528\u6c14\u91cf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">7.3 10\u5e74\u8ddf\u8e2a\u00b7\u56db\u4e2a\u8def\u6807<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9636\u6bb5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ea4\u4ed8\u7269<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udcd8 \u57fa\u51c6\u5efa\u7acb\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c1\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udcc8 \u6548\u679c\u9a8c\u8bc1\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c3\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udd27 \u6df1\u5ea6\u89e3\u6790\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c5\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83c\udfaf \u627f\u8bfa\u5151\u73b0\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c10\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u300b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 id=\"bltx08\" class=\"wp-block-heading has-medium-font-size\">\u3010\u7b2c8\u9879\uff1a\u670d\u52a1\u627f\u8bfa\u3011<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b9e\u4f8b\u5370\u8bc1<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td class=\"has-text-align-left\" data-align=\"left\">48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u4f4d\u5ba2\u6237\u5747\u4eab\u6b64\u670d\u52a1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672c\u65b9\u6848\u4e66\u5373\u4e3a\u5b9e\u4f8b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u6807\u51c6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9e93\u6e56\u5468\u8001\u5e08\u6863\u6848\uff1a0.8MPa\u4fdd\u538b48\u5c0f\u65f6\uff0c\u538b\u964d0.1MPa<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907+\u5b89\u88c5+\u8f85\u6750\u5206\u5217<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672c\u65b9\u6848\u9010\u9879\u5217\u660e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5165\u4f1a\u5458\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9e93\u6e56\u5468\u8001\u5e08\u6863\u6848\uff1a2026\u5e745\u670811\u65e5\u56de\u8bbf\u8bb0\u5f55<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 id=\"bltx09\" class=\"wp-block-heading has-medium-font-size\">\u3010\u7b2c9\u9879\uff1a\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\u3011<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9009\u62e9\u9f99\u8109\u6696\u901a\uff0c\u60a8\u83b7\u5f97\u7684\u4e0d\u4ec5\u662f\u4e00\u5957\u8bbe\u5907\uff0c\u66f4\u662f\u4e00\u4efd\u53ef\u8ffd\u6eaf\u3001\u53ef\u9a8c\u8bc1\u3001\u53ef\u89c6\u5316\u7684\u5b8c\u6574\u670d\u52a1\u6863\u6848\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6863\u6848\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udcf8 \u65bd\u5de5\u5168\u6d41\u7a0b\u7167\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ece\u9690\u853d\u5de5\u7a0b\u5230\u7ae3\u5de5\u9a8c\u6536\uff0c\u6bcf\u4e2a\u5173\u952e\u8282\u70b9\u5747\u6709\u7167\u7247\u5b58\u6863<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udccb \u8bbe\u5907\u6e05\u5355\u4e0e\u9a8c\u6536\u5355<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u578b\u53f7\u3001\u5e8f\u5217\u53f7\u3001\u5b89\u88c5\u4f4d\u7f6e\u5168\u7a0b\u8bb0\u5f55<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udcca 10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u91c7\u6696\u5b63\u80fd\u8017\u6570\u636e\u91c7\u96c6\uff0c\u51fa\u5177\u5e74\u5ea6\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83d\udd27 \u552e\u540e\u8bb0\u5f55<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u6b21\u7ef4\u4fdd\u3001\u68c0\u6d4b\u3001\u6e05\u6d17\u5747\u6709\u8be6\u7ec6\u8bb0\u5f55<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcce \u67e5\u770b\u771f\u5b9e\u6863\u6848\u793a\u4f8b\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=540\">\u9e93\u6e56\u5468\u8001\u5e08\u5730\u6696\u6863\u6848<\/a>\uff08\u5e73\u5c4298.8\u33a1\uff0c\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf\uff09<\/p>\n\n\n\n<h4 id=\"bltx10\" class=\"wp-block-heading\">\u3010\u7b2c10\u9879\uff1a\u6743\u5a01\u80cc\u4e66\u9875\u3011<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u80cc\u4e66\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9a8c\u8bc1\u65b9\u5f0f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u56fd\u6807\u6761\u6b3e<\/td><td class=\"has-text-align-left\" data-align=\"left\">GB 50736-2012\u3001JGJ 142-2012<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf\u53ef\u67e5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u56fd\u6807\u6761\u6b3e<\/td><td class=\"has-text-align-left\" data-align=\"left\">GB 20665-2015\uff1a\u51b7\u51dd\u7089\u70ed\u6548\u7387\u226598%\u4e3a\u4e00\u7ea7\u80fd\u6548<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u4e0a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5382\u5bb6\u6280\u672f\u624b\u518c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\u8bbe\u8ba1\u624b\u518c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\u5b98\u65b9\u6280\u672f\u652f\u6301\u53ef\u9a8c\u8bc1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u54c1\u8d28\u8ba4\u8bc1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d77\u4fe1\u65e5\u7acb\u9ec4\u5c9b\u5de5\u5382\u2014\u2014\u5168\u7403\u9996\u5ea7\u591a\u8054\u673a\u4e2d\u592e\u7a7a\u8c03\u706f\u5854\u5de5\u5382<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e16\u754c\u7ecf\u6d4e\u8bba\u575b\u5b98\u7f51\u53ef\u67e5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"bltx11\" class=\"wp-block-heading\">\u3010\u7b2c11\u9879\uff1a\u5b89\u88c5\u4e0e\u552e\u540e\u4fdd\u969c\u3011<\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">11.1 \u5b89\u88c5\u6d41\u7a0b\uff08\u7cbe\u5de5\u516d\u6b65\u6cd5+2\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9636\u6bb5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u5e8f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5173\u952e\u8282\u70b9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c1\u6b65<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u73b0\u573a\u52d8\u6d4b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u7ba1\u8def\u8d70\u5411\u3001\u5206\u6c34\u7bb1\u4f4d\u7f6e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c2\u6b65<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u51fa\u56fe<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u76d8\u7ba1\u56fe\u7eb8\u3001\u5206\u96c6\u6c34\u5668\u5e03\u7f6e\u56fe<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c3\u6b65<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9690\u853d\u5de5\u7a0b\u65bd\u5de5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u76d8\u7ba1\u94fa\u8bbe\u3001\u4fdd\u6e29\u5c42\u3001\u6253\u538b\u6d4b\u8bd5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c4\u6b65<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u5b89\u88c5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u3001\u4e3b\u7ba1\u8fde\u63a5\u3001\u8054\u52a8\u63a7\u5236\u5b89\u88c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c5\u6b65<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u8c03\u8bd5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8865\u6c34\u3001\u6d4b\u8bd5\u8054\u52a8\u529f\u80fd\u3001\u8bbe\u5b9a\u4f9b\u6c34\u6e29\u5ea6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c6\u6b65<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ae3\u5de5\u9a8c\u6536<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5404\u623f\u95f4\u6e29\u5ea6\u6d4b\u8bd5\u3001APP\u63a7\u5236\u6f14\u793a\u3001\u9a8c\u6536\u5355\u7b7e\u5b57<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">+1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ea4\u4ed8\u6559\u5b66<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u64cd\u4f5c\u3001\u6e29\u63a7\u5668\u4f7f\u7528\u3001APP\u8fdc\u7a0b\u63a7\u5236<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">+2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u552e\u540e\u4fdd\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u8d28\u4fdd\u3001\u5de5\u7a0b\u8d28\u4fdd\u3001\u4e09\u65b9\u8054\u4fdd\u3001\u5e74\u5ea6\u7ef4\u4fdd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">11.2 \u552e\u540e\u4fdd\u969c<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u969c\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u8d28\u4fdd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\u5382\u5bb6\u8d28\u4fdd + \u9f99\u8109\u5de5\u7a0b\u8d28\u4fdd5\u5e74\u8d77<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e09\u65b9\u8054\u4fdd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9f99\u8109\u6696\u901a + \u4f1f\u661f\u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f1a\u5458\u5ef6\u4fdd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5165\u4f1a\u540e\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e74\u5ea6\u68c0\u6d4b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u91c7\u6696\u5b63\u524d\u514d\u8d39\u4e0a\u95e8\u68c0\u6d4b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u4fdd\u63d0\u9192<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u81ea\u52a8\u63a8\u9001\u6e05\u6d17\u3001\u6ee4\u7f51\u66f4\u6362\u7b49\u7ef4\u62a4\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 id=\"bltx12\" class=\"wp-block-heading\">\u3010\u7b2c12\u9879\uff1a\u5408\u540c\u7b7e\u5b9a\u3011<\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c3-768x1024.jpg\" alt=\"\" class=\"wp-image-2150\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c3-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c3-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c3.jpg 1057w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c1-768x1024.jpg\" alt=\"\" class=\"wp-image-2151\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c1-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c1-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c1.jpg 1147w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c2.jpg\" alt=\"\" class=\"wp-image-2152\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c2.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c2-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u9879\u76ee\u5408\u540c2-768x576.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53551-768x1024.jpg\" alt=\"\" class=\"wp-image-2113\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53551-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53551-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53551-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53551-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53551-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53552-768x1024.jpg\" alt=\"\" class=\"wp-image-2114\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53552-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53552-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53552-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53552-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53552-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53553-768x1024.jpg\" alt=\"\" class=\"wp-image-2115\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53553-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53553-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53553-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53553-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53553-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53554-768x1024.jpg\" alt=\"\" class=\"wp-image-2118\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53554-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53554-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53554-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53554-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53554-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53555-768x1024.jpg\" alt=\"\" class=\"wp-image-2119\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53555-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53555-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53555-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53555-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53555-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53556-768x1024.jpg\" alt=\"\" class=\"wp-image-2120\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53556-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53556-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53556-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53556-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53556-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53557-768x1024.jpg\" alt=\"\" class=\"wp-image-2121\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53557-768x1024.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53557-225x300.jpg 225w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53557-1152x1536.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53557-1536x2048.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/\u4fdd\u5229\u5929\u73ba\u5408\u540c\u914d\u7f6e\u6e05\u53557-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u9ec4\u52c7 | <strong>\u8054\u7cfb\u7535\u8bdd<\/strong>\uff1a[15828489188]<br><strong>\u9f99\u8109\u6696\u901a<\/strong>\uff1a\u59cb\u4e8e2004\uff0c\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf22\u5e74<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/longmai-nt.com\/?page_id=982#yjd02\">\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/a><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\uff1a\u5468\u8001\u5e08\u9879\u76ee\u5730\u5740\uff1a\u4fdd\u5229\u5929\u73ba\uff0c\u91c7\u6696\u9762\u79ef [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1327","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1327\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5ba2\u6237\uff1a\u5468\u8001\u5e08\u9879\u76ee\u5730\u5740\uff1a\u4fdd\u5229\u5929\u73ba\uff0c\u91c7\u6696\u9762\u79ef [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1327\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-05T02:38:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327\",\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/845c60d9b4e4b5ee2b1381b586f05786.jpg\",\"datePublished\":\"2026-05-30T07:31:44+00:00\",\"dateModified\":\"2026-06-05T02:38:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/845c60d9b4e4b5ee2b1381b586f05786.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/845c60d9b4e4b5ee2b1381b586f05786.jpg\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1327#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1327","og_locale":"zh_CN","og_type":"article","og_title":"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u5ba2\u6237\uff1a\u5468\u8001\u5e08\u9879\u76ee\u5730\u5740\uff1a\u4fdd\u5229\u5929\u73ba\uff0c\u91c7\u6696\u9762\u79ef [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=1327","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-05T02:38:00+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1327","url":"https:\/\/longmai-nt.com\/?page_id=1327","name":"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=1327#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=1327#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg","datePublished":"2026-05-30T07:31:44+00:00","dateModified":"2026-06-05T02:38:00+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1327#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1327"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=1327#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/845c60d9b4e4b5ee2b1381b586f05786.jpg","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1327#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9f99\u8109\u6696\u901a\u00b7\u4fdd\u5229\u5929\u73ba\u5468\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6863\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1327"}],"version-history":[{"count":22,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1327\/revisions"}],"predecessor-version":[{"id":2157,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1327\/revisions\/2157"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}