{"id":1337,"date":"2026-05-22T18:12:07","date_gmt":"2026-05-22T10:12:07","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1337"},"modified":"2026-05-23T20:28:44","modified_gmt":"2026-05-23T12:28:44","slug":"%e6%8c%87%e4%bb%a406%ef%bc%9a%e8%be%85%e6%9d%90%e9%85%8d%e7%bd%ae%e6%b8%85%e5%8d%95-ds%e8%87%aa%e5%8a%a8%e7%94%9f%e6%88%90%e8%a7%84%e5%88%99-v2-0","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1337","title":{"rendered":"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl0601\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e00\u3001\u6307\u4ee4\u76ee\u6807<\/a><\/li>\n\n\n\n<li><a href=\"#zl0602\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u3001\u9002\u7528\u573a\u666f<\/a><\/li>\n\n\n\n<li><a href=\"#zl0603\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e09\u3001\u5b89\u5168\u9ed8\u8ba4\u503c<\/a><\/li>\n\n\n\n<li><a href=\"#zl0604\" target=\"_blank\" rel=\"noreferrer noopener\">\u56db\u3001\u6838\u5fc3\u89c4\u5219<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#zl06041\" target=\"_blank\" rel=\"noreferrer noopener\">4.1 \u7cfb\u7edf\u7c7b\u578b\u4e0e\u9644\u8868\u6620\u5c04<\/a><\/li>\n\n\n\n<li><a href=\"#zl06042\" target=\"_blank\" rel=\"noreferrer noopener\">4.2 \u9ed8\u8ba4\u4e0e\u53ef\u9009\u89c4\u5219<\/a><\/li>\n\n\n\n<li><a href=\"#zl06043\" target=\"_blank\" rel=\"noreferrer noopener\">4.3 \u591a\u7cfb\u7edf\u7ec4\u5408\u8f93\u51fa\u987a\u5e8f<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#zl0605\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e94\u3001\u6267\u884c\u6b65\u9aa4<\/a><\/li>\n\n\n\n<li><a href=\"#zl0606\" target=\"_blank\" rel=\"noreferrer noopener\">\u516d\u3001\u8f93\u51fa\u7269\u683c\u5f0f<\/a><\/li>\n\n\n\n<li><a href=\"#zl0607\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e03\u3001\u9a8c\u8bc1\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl0608\" target=\"_blank\" rel=\"noreferrer noopener\">\u516b\u3001\u7981\u6b62\u884c\u4e3a<\/a><\/li>\n\n\n\n<li><a href=\"#zl0609\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e5d\u3001\u5e38\u89c1\u9519\u8bef<\/a><\/li>\n\n\n\n<li><a href=\"#zl0610\" target=\"_blank\" rel=\"noreferrer noopener\">\u5341\u3001\u5173\u8054\u77e5\u8bc6\u5e93<\/a><\/li>\n\n\n\n<li id=\"zl0601\"><a href=\"#zl06fl\" target=\"_blank\" rel=\"noreferrer noopener\">\u9644\u5f55\uff1a\u4e03\u5f20\u8f85\u6750\u9644\u8868<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl01\">\u9644\u8868A\uff1a\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl02\">\u9644\u8868B\uff1a\u65b0\u98ce\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl03\">\u9644\u8868C\uff1a\u5730\u6696\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl04\">\u9644\u8868D\uff1a\u6697\u57cb\u6696\u6c14\u7247\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl05\">\u9644\u8868E\uff1a\u660e\u88c5\u6696\u6c14\u7247\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl06\">\u9644\u8868F\uff1a\u6c34\u673a\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"#zl06fl07\">\u9644\u8868G\uff1a\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e00\u3001\u6307\u4ee4\u76ee\u6807<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8ba9DS\u5728\u751f\u6210\u65b9\u6848\u4e66\uff08\u62a5\u4ef7\u4e66\uff09\u672b\u5c3e\uff0c\u6839\u636e\u7cfb\u7edf\u7c7b\u578b\u81ea\u52a8\u8ffd\u52a0\u300a\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355\u300b\uff0c\u4f7f\u5ba2\u6237\u660e\u786e\u9690\u853d\u5de5\u7a0b\u6240\u7528\u7684\u54c1\u724c\u3001\u89c4\u683c\u4e0e\u5de5\u827a\u6807\u51c6\u3002\u8f85\u6750\u6e05\u5355\u4e0d\u6d89\u53ca\u62a5\u4ef7\u91d1\u989d\uff0c\u4ec5\u5217\u54c1\u724c+\u89c4\u683c+\u529f\u80fd\u8bf4\u660e\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0602\" class=\"wp-block-heading\">\u4e8c\u3001\u9002\u7528\u573a\u666f<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">DS\u52a8\u4f5c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e6\u53d1\u6761\u4ef6<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u677f\u5757\u4e09\u00b7\u65b9\u6848\u62a5\u4ef7<\/td><td>\u62a5\u4ef7\u672b\u5c3e\u81ea\u52a8\u8ffd\u52a0\u8f85\u6750\u6e05\u5355<\/td><td>\u4efb\u4f55\u5305\u542b\u8bbe\u5907\u7cfb\u7edf\u7684\u65b9\u6848<\/td><\/tr><tr><td>\u5ba2\u6237\u8be2\u95ee\u8f85\u6750\u54c1\u724c\/\u89c4\u683c<\/td><td>\u67e5\u8be2\u5bf9\u5e94\u9644\u8868\u539f\u6587\u8f93\u51fa<\/td><td>\u5ba2\u6237\u4e3b\u52a8\u63d0\u95ee<\/td><\/tr><tr><td>\u9500\u552e\u4eba\u5458\u6307\u5b9a\u5347\u7ea7\u53ef\u9009\u8f85\u6750<\/td><td>\u66ff\u6362\u9ed8\u8ba4\u89c4\u683c\uff0c\u6807\u6ce8&#8221;\u5ba2\u6237\u9009\u914d\u5347\u7ea7&#8221;<\/td><td>\u9500\u552e\u4eba\u5458\u660e\u786e\u6307\u4ee4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0603\" class=\"wp-block-heading\">\u4e09\u3001\u5b89\u5168\u9ed8\u8ba4\u503c<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u9ed8\u8ba4\u4f18\u5148<\/strong>\uff1a\u6240\u6709\u8f85\u6750\u4e00\u5f8b\u6309&#8221;\u9ed8\u8ba4&#8221;\u89c4\u683c\u8f93\u51fa\uff0c\u4e0d\u5f97\u64c5\u81ea\u4f7f\u7528&#8221;\u53ef\u9009&#8221;\u89c4\u683c<\/li>\n\n\n\n<li><strong>\u54c1\u724c\u4e0d\u53ef\u865a\u6784<\/strong>\uff1a\u9644\u8868\u4e2d\u5217\u51fa\u7684\u54c1\u724c\u662f\u552f\u4e00\u5408\u6cd5\u54c1\u724c\uff0cDS\u4e0d\u5f97\u66ff\u6362\u6216\u7f16\u9020<\/li>\n\n\n\n<li><strong>\u89c4\u683c\u4e0d\u63a8\u65ad<\/strong>\uff1a\u9644\u8868\u4e2d\u672a\u6307\u5b9a\u7684\u89c4\u683c\u578b\u53f7\u4e0d\u5f97\u81ea\u884c\u63a8\u65ad\u586b\u5145<\/li>\n\n\n\n<li><strong>\u4e0d\u542b\u4ef7\u683c<\/strong>\uff1a\u8f85\u6750\u6e05\u5355\u4e2d\u4e0d\u8f93\u51fa\u4efb\u4f55\u4ef7\u683c\u3001\u91d1\u989d<\/li>\n\n\n\n<li><strong>\u4e0d\u542b\u65bd\u5de5\u6307\u5bfc<\/strong>\uff1a\u8f85\u6750\u6e05\u5355\u4ec5\u5217\u6750\u6599\uff0c\u4e0d\u8f93\u51fa\u65bd\u5de5\u6b65\u9aa4\u6216\u5b89\u88c5\u6307\u5bfc<\/li>\n\n\n\n<li><strong>\u4e0d\u8de8\u7cfb\u7edf\u6df7\u7528<\/strong>\uff1a\u4e0d\u540c\u7cfb\u7edf\u7684\u8f85\u6750\u6e05\u5355\u72ec\u7acb\u8f93\u51fa\uff0c\u4e0d\u5f97\u6df7\u5408<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0604\" class=\"wp-block-heading\">\u56db\u3001\u6838\u5fc3\u89c4\u5219<\/h2>\n\n\n\n<h3 id=\"zl06041\" class=\"wp-block-heading\">4.1 \u7cfb\u7edf\u7c7b\u578b\u4e0e\u9644\u8868\u6620\u5c04<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9644\u8868<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u6761\u4ef6<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u7eaf\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u9644\u8868A<\/td><td>\u8212\u4eab\u7cfb\u5217\u3001VAM mini\u7cfb\u5217\u3001\u5c0a\u777f\u7cfb\u5217\u3001\u5c0a\u777f\u5168\u6548\u7cfb\u5217<\/td><\/tr><tr><td>\u65b0\u98ce\u7cfb\u7edf<\/td><td>\u9644\u8868B<\/td><td>\u5355\u5411\u6d41\u65b0\u98ce\u3001\u4e91\u51c0\u65b0\u98ce\u3001\u4e91\u51c0\u2161\u65b0\u98ce<\/td><\/tr><tr><td>\u72ec\u7acb\u5730\u6696\u7cfb\u7edf<\/td><td>\u9644\u8868C<\/td><td>\u71c3\u6c14\u58c1\u6302\u7089\u6216\u7a7a\u6c14\u80fd\u70ed\u6e90<\/td><\/tr><tr><td>\u6697\u57cb\u6696\u6c14\u7247\u7cfb\u7edf<\/td><td>\u9644\u8868D<\/td><td>\u7ae0\u9c7c\u5f0f\u6697\u88c5\u6696\u6c14\u7247<\/td><\/tr><tr><td>\u660e\u88c5\u6696\u6c14\u7247\u7cfb\u7edf<\/td><td>\u9644\u8868E<\/td><td>\u5df2\u88c5\u4fee\u623f\u5c4b\u660e\u88c5\u6696\u6c14\u7247<\/td><\/tr><tr><td>\u6c34\u673a\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09<\/td><td>\u9644\u8868F<\/td><td>\u65e5\u7acb\u6c34\u5885\u9002\u7cfb\u5217<\/td><\/tr><tr><td>\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b<\/td><td>\u9644\u8868G<\/td><td>\u65e5\u7acb\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 id=\"zl06042\" class=\"wp-block-heading\">4.2 \u9ed8\u8ba4\u4e0e\u53ef\u9009\u89c4\u5219<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9644\u8868\u4e2d\u6807\u6ce8&#8221;\uff08\u9ed8\u8ba4\uff09&#8221;\u7684\u89c4\u683c \u2192 DS\u5fc5\u987b\u8f93\u51fa<\/li>\n\n\n\n<li>\u9644\u8868\u4e2d\u6807\u6ce8&#8221;\uff08\u53ef\u9009\uff09&#8221;\u7684\u89c4\u683c \u2192 DS\u4e0d\u5f97\u8f93\u51fa\uff0c\u9664\u975e\u9500\u552e\u4eba\u5458\u660e\u786e\u6307\u5b9a\u5347\u7ea7<\/li>\n\n\n\n<li>\u9500\u552e\u4eba\u5458\u6307\u5b9a\u5347\u7ea7\u65f6 \u2192 \u5c06\u5bf9\u5e94\u884c\u7684\u9ed8\u8ba4\u89c4\u683c\u66ff\u6362\u4e3a\u53ef\u9009\u89c4\u683c\uff0c\u5e76\u5728\u8be5\u884c\u672b\u5c3e\u6807\u6ce8&#8221;\uff08\u5ba2\u6237\u9009\u914d\u5347\u7ea7\uff09&#8221;<\/li>\n\n\n\n<li>\u540c\u4e00\u7c7b\u522b\u4e0b\u7684\u53ef\u9009\u89c4\u683c\u53ef\u80fd\u6709\u591a\u9879\uff08\u5982\u5730\u6696\u4fdd\u6e29\u677f\u6709\u8bfa\u5c14\u6324\u5851\u677f\u9ed8\u8ba4\u3001\u4f1f\u661f\u767d\u6676\u677f\u53ef\u9009\u3001\u7eff\u7fbd\u767d\u6676\u677f\u53ef\u9009\uff09\uff0c\u9500\u552e\u4eba\u5458\u9009\u5b9a\u5176\u4e2d\u4e00\u9879\u540e\u624d\u66ff\u6362<\/li>\n<\/ul>\n\n\n\n<h3 id=\"zl06043\" class=\"wp-block-heading\">4.3 \u591a\u7cfb\u7edf\u7ec4\u5408\u8f93\u51fa\u987a\u5e8f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u65b9\u6848\u5305\u542b\u591a\u4e2a\u7cfb\u7edf\u65f6\uff0c\u6309\u4ee5\u4e0b\u987a\u5e8f\u8ffd\u52a0\u9644\u8868\uff1a<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">\u7a7a\u8c03 \u2192 \u65b0\u98ce \u2192 \u5730\u6696\/\u6696\u6c14\u7247\n<\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bcf\u4e2a\u9644\u8868\u4ee5\u72ec\u7acb\u5206\u8282\u6807\u9898\u9694\u5f00\uff0c\u8f93\u51fa\u4e3a\u65b9\u6848\u4e66\u672b\u5c3e\u7684\u72ec\u7acb\u7ae0\u8282\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0605\" class=\"wp-block-heading\">\u4e94\u3001\u6267\u884c\u6b65\u9aa4<\/h2>\n\n\n\n<pre class=\"wp-block-preformatted\">\u65b9\u6848\u4e66\u751f\u6210\u5b8c\u6210\n  \u2502\n  \u251c\u2500 \u6b65\u9aa41\uff1a\u8bc6\u522b\u65b9\u6848\u4e2d\u6d89\u53ca\u7684\u7cfb\u7edf\u7c7b\u578b\n  \u2502   \u68c0\u67e5\u65b9\u6848\u4e2d\u662f\u5426\u5305\u542b\uff1a\u4e2d\u592e\u7a7a\u8c03\/\u65b0\u98ce\/\u5730\u6696\/\u6696\u6c14\u7247\/\u4e24\u8054\u4f9b\n  \u2502\n  \u251c\u2500 \u6b65\u9aa42\uff1a\u5339\u914d\u9644\u8868\n  \u2502   \u63094.1\u6620\u5c04\u8868\uff0c\u786e\u5b9a\u6bcf\u4e2a\u7cfb\u7edf\u5bf9\u5e94\u7684\u9644\u8868\u7f16\u53f7\n  \u2502\n  \u251c\u2500 \u6b65\u9aa43\uff1a\u786e\u5b9a\u89c4\u683c\u5c42\u7ea7\n  \u2502   \u9ed8\u8ba4\u5168\u90e8\u9009\u9ed8\u8ba4\u89c4\u683c\u3002\u68c0\u67e5\u9500\u552e\u4eba\u5458\u662f\u5426\u6709\"\u5347\u7ea7\u53ef\u9009\u8f85\u6750\"\u6307\u4ee4\n  \u2502\n  \u251c\u2500 \u6b65\u9aa44\uff1a\u63094.3\u987a\u5e8f\u4f9d\u6b21\u8f93\u51fa\u9644\u8868\n  \u2502   \u6bcf\u4e2a\u9644\u8868\u5305\u542b\uff1a\u6807\u9898 + \u54c1\u724c\/\u540d\u79f0\/\u89c4\u683c\u578b\u53f7\/\u6570\u91cf\/\u529f\u80fd\u4e94\u5217\u8868\u683c + \u8bf4\u660e\u6761\u6b3e\n  \u2502\n  \u2514\u2500 \u6b65\u9aa45\uff1a\u5c06\u8f85\u6750\u6e05\u5355\u8ffd\u52a0\u5230\u65b9\u6848\u4e66\u672b\u5c3e\n      \u4f5c\u4e3a\u72ec\u7acb\u7ae0\u8282\uff0c\u6807\u9898\u4e3a\"\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355\"\n<\/pre>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0606\" class=\"wp-block-heading\">\u516d\u3001\u8f93\u51fa\u7269\u683c\u5f0f<\/h2>\n\n\n\n<h3 id=\"zl06061\" class=\"wp-block-heading\">6.1 \u6807\u9898\u683c\u5f0f<\/h3>\n\n\n\n<pre class=\"wp-block-preformatted\">markdown<code>## \u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355\n\n### {\u7cfb\u7edf\u540d\u79f0}\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\n\n**\u9002\u7528\u7cfb\u7edf**\uff1a{\u7cfb\u5217\u540d\u79f0}\n<\/code><\/pre>\n\n\n\n<h3 id=\"zl06062\" class=\"wp-block-heading\">6.2 \u8868\u683c\u683c\u5f0f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bcf\u4e2a\u9644\u8868\u91c7\u7528\u4e94\u5217 Markdown \u8868\u683c\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n\n\n<p class=\"wp-block-paragraph\">\u6682\u65e0\u6570\u636e<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u54c1\u724c\u5217\uff1a\u4f7f\u7528\u9644\u8868\u539f\u6587\u7684\u54c1\u724c\u540d\u79f0\uff08\u5982&#8221;\u9f99\u715c&#8221;\u3001&#8221;\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)&#8221;\u3001&#8221;\u4f1f\u661f&#8221;\u7b49\uff09<\/li>\n\n\n\n<li>\u6570\u91cf\u5217\uff1a\u9644\u8868\u6807\u6ce8&#8221;\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645&#8221;\u7684\uff0c\u539f\u6587\u7167\u6284<\/li>\n\n\n\n<li>\u529f\u80fd\u5217\uff1a\u9644\u8868\u539f\u6587\u7684\u529f\u80fd\u63cf\u8ff0\uff0c\u539f\u6587\u7167\u6284<\/li>\n<\/ul>\n\n\n\n<h3 id=\"zl06063\" class=\"wp-block-heading\">6.3 \u8bf4\u660e\u6761\u6b3e\u683c\u5f0f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868\u683c\u540e\u4ee5\u7f16\u53f7\u5217\u8868\u8f93\u51fa\u8bf4\u660e\u6761\u6b3e\uff0c\u6bcf\u6761\u4ee5&#8221;1\u3001&#8221;\u5f00\u5934\uff0c\u539f\u6587\u7167\u6284\u3002\u5fc5\u987b\u5305\u542b\u6240\u6709\u8bf4\u660e\u6761\u6b3e\uff0c\u4e0d\u5f97\u5220\u51cf\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0607\" class=\"wp-block-heading\">\u4e03\u3001\u9a8c\u8bc1\u6e05\u5355<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DS\u8f93\u51fa\u540e\u81ea\u67e5\u4ee5\u4e0b7\u9879\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;1. \u8f85\u6750\u6e05\u5355\u662f\u5426\u8ffd\u52a0\u5230\u65b9\u6848\u4e66\u672b\u5c3e\uff08\u800c\u975e\u5185\u5d4c\u5728\u62a5\u4ef7\u8868\u4e2d\uff09\uff1f<\/li>\n\n\n\n<li>&nbsp;2. \u7cfb\u7edf\u7c7b\u578b\u4e0e\u9644\u8868\u662f\u5426\u6b63\u786e\u5339\u914d\uff08\u7eaf\u6c1f\u7a7a\u8c03\u2192A\uff0c\u65b0\u98ce\u2192B\uff0c\u5730\u6696\u2192C\uff0c\u4ee5\u6b64\u7c7b\u63a8\uff09\uff1f<\/li>\n\n\n\n<li>&nbsp;3. \u6240\u6709\u8f85\u6750\u662f\u5426\u5747\u4e3a&#8221;\u9ed8\u8ba4&#8221;\u89c4\u683c\uff08\u9500\u552e\u4eba\u5458\u672a\u6307\u5b9a\u5347\u7ea7\u65f6\uff09\uff1f<\/li>\n\n\n\n<li>&nbsp;4. \u8868\u683c\u662f\u5426\u4e94\u5217\u5b8c\u6574\uff1a\u54c1\u724c\/\u540d\u79f0\/\u89c4\u683c\u578b\u53f7\/\u6570\u91cf\/\u529f\u80fd\uff1f<\/li>\n\n\n\n<li>&nbsp;5. \u8bf4\u660e\u6761\u6b3e\u662f\u5426\u5168\u90e8\u8f93\u51fa\u3001\u65e0\u5220\u51cf\uff1f<\/li>\n\n\n\n<li>&nbsp;6. \u591a\u7cfb\u7edf\u65b9\u6848\u662f\u5426\u6309&#8221;\u7a7a\u8c03\u2192\u65b0\u98ce\u2192\u5730\u6696\/\u6696\u6c14\u7247&#8221;\u987a\u5e8f\u6392\u5217\uff1f<\/li>\n\n\n\n<li>&nbsp;7. \u8f85\u6750\u6e05\u5355\u4e2d\u662f\u5426<strong>\u6ca1\u6709\u4efb\u4f55\u4ef7\u683c\/\u91d1\u989d<\/strong>\uff1f<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0608\" class=\"wp-block-heading\">\u516b\u3001\u7981\u6b62\u884c\u4e3a<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u7981\u6b62\u64c5\u81ea\u4f7f\u7528\u53ef\u9009\u89c4\u683c<\/strong>\uff1a\u9664\u975e\u9500\u552e\u4eba\u5458\u660e\u786e\u6307\u4ee4\uff0c\u5426\u5219\u7981\u6b62\u8f93\u51fa\u4efb\u4f55\u6807\u6ce8&#8221;\u53ef\u9009&#8221;\u7684\u8f85\u6750<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u865a\u6784\u54c1\u724c<\/strong>\uff1a\u9644\u8868\u4e2d\u672a\u51fa\u73b0\u7684\u54c1\u724c\uff0c\u4e0d\u5f97\u81ea\u884c\u6dfb\u52a0<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u63a8\u65ad\u89c4\u683c<\/strong>\uff1a\u9644\u8868\u4e2d\u89c4\u683c\u578b\u53f7\u7559\u7a7a\u6216\u5199&#8221;\u9002\u914d&#8221;\u7684\uff0c\u539f\u6587\u7167\u6284\uff0c\u4e0d\u5f97\u81ea\u884c\u63a8\u65ad\u5177\u4f53\u53c2\u6570<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u5728\u8f85\u6750\u6e05\u5355\u4e2d\u6807\u6ce8\u4ef7\u683c<\/strong>\uff1a\u8f85\u6750\u6e05\u5355\u662f\u5c55\u793a\u9690\u853d\u5de5\u7a0b\u7528\u6599\uff0c\u4e0d\u662f\u62a5\u4ef7<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u5220\u51cf\u8bf4\u660e\u6761\u6b3e<\/strong>\uff1a\u6bcf\u4e2a\u9644\u8868\u672b\u5c3e\u7684\u8bf4\u660e\u6761\u6b3e\u662f\u5408\u540c\u7ea6\u5b9a\u7684\u7ec4\u6210\u90e8\u5206\uff0c\u4e00\u6761\u90fd\u4e0d\u80fd\u5c11<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u6df7\u7528\u4e0d\u540c\u7cfb\u7edf\u7684\u9644\u8868<\/strong>\uff1a\u5929\u6c1f\u5730\u6c34\u4e0d\u5957\u7528\u6c34\u673a\u4e24\u8054\u4f9b\u7684\u9644\u8868\uff08\u867d\u7136\u90fd\u6d89\u53ca\u91c7\u6696\uff09<\/li>\n\n\n\n<li><strong>\u7981\u6b62\u8f93\u51faemoji\u7b26\u53f7<\/strong>\uff1a\u5168\u6587\u6863\u7981\u7528<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0609\" class=\"wp-block-heading\">\u4e5d\u3001\u5e38\u89c1\u9519\u8bef<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9519\u8bef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6b63\u786e\u505a\u6cd5<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u65b9\u6848\u53ea\u542b\u65b0\u98ce\u7cfb\u7edf\uff0c\u5374\u8f93\u51fa\u4e86\u7a7a\u8c03\u8f85\u6750\u8868<\/td><td>\u65b0\u98ce\u2192\u9644\u8868B\uff0c\u4e0e\u7a7a\u8c03\u65e0\u5173<\/td><\/tr><tr><td>\u5730\u6696\u4fdd\u6e29\u677f\u64c5\u81ea\u9009\u4e86\u4f1f\u661f\u767d\u6676\u677f<\/td><td>\u9ed8\u8ba4\u662f\u8bfa\u5c14\u6324\u5851\u677f\uff0c\u9664\u975e\u9500\u552e\u6307\u5b9a\u5347\u7ea7<\/td><\/tr><tr><td>\u8f85\u6750\u6e05\u5355\u4e2d\u5199\u4e86&#8221;\u7ea6XX\u5143&#8221;<\/td><td>\u8f85\u6750\u6e05\u5355\u4e0d\u542b\u4ef7\u683c\uff0c\u4ec5\u5217\u54c1\u724c\u89c4\u683c<\/td><\/tr><tr><td>\u591a\u7cfb\u7edf\u65b9\u6848\u53ea\u8f93\u4e86\u4e00\u4efd\u6e05\u5355<\/td><td>\u6bcf\u4e2a\u7cfb\u7edf\u72ec\u7acb\u8f93\u51fa\u5bf9\u5e94\u9644\u8868<\/td><\/tr><tr><td>\u5929\u6c1f\u5730\u6c34\u5957\u7528\u4e86\u6c34\u673a\u4e24\u8054\u4f9b\u7684\u9644\u8868<\/td><td>\u5929\u6c1f\u5730\u6c34\u2192\u9644\u8868G\uff0c\u6c34\u673a\u2192\u9644\u8868F<\/td><\/tr><tr><td>\u8bf4\u660e\u6761\u6b3e\u53ea\u5217\u4e86\u524d\u51e0\u6761<\/td><td>\u5fc5\u987b\u5168\u90e8\u8f93\u51fa\uff0c\u4e00\u6761\u4e0d\u5c11<\/td><\/tr><tr><td>\u8868\u683c\u4f7f\u7528emoji\u7b26\u53f7\u4ee3\u66ff\u6587\u5b57<\/td><td>\u5168\u6587\u6863\u7eaf\u6587\u5b57\uff0c\u7981\u7528emoji<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl0610\" class=\"wp-block-heading\">\u5341\u3001\u5173\u8054\u77e5\u8bc6\u5e93<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6587\u6863<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7528\u9014<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f4d\u7f6e<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u6307\u4ee40\u00b7\u5baa\u6cd5<\/td><td>\u677f\u5757\u4e09\u65b9\u6848\u751f\u6210\u6d41\u7a0b\u3001\u8f85\u6750\u6e05\u5355\u8ffd\u52a0\u4f4d\u7f6e<\/td><td>\u6307\u4ee40<\/td><\/tr><tr><td>\u6307\u4ee41\u00b7\u8bbe\u8ba1\u89c4\u8303\u4e0e\u77e5\u8bc6\u7d22\u5f15<\/td><td>\u7cfb\u7edf\u7c7b\u578b\u5224\u65ad\u6807\u51c6\u3001\u8bbe\u8ba1\u53c2\u6570<\/td><td>\u6307\u4ee41<\/td><\/tr><tr><td>\u6307\u4ee42\u00b7\u4ef7\u683c\u8868<\/td><td>\u8bbe\u5907\/\u4e3b\u6750\u62a5\u4ef7\u53c2\u8003<\/td><td>\u6307\u4ee42<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zl06fl\" class=\"wp-block-heading\">\u9644\u5f55\uff1a\u4e03\u5f20\u8f85\u6750\u9644\u8868<\/h2>\n\n\n\n<h3 id=\"zl06fl01\" class=\"wp-block-heading\">\u9644\u8868A\uff1a\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u8212\u4eab\u7cfb\u5217\u3001VAM mini\u7cfb\u5217\u3001\u5c0a\u777f\u7cfb\u5217\u3001\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff08\u7eaf\u6c1f\u7cfb\u7edf\uff09<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u7a7a\u8c03\u98ce\u7cfb\u7edf\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u7b49\u4e8e\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u7ba1\u8def\u7cfb\u7edf\u53ca\u8f85\u6599\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5bf9\u51b7\u5a92\u8fdb\u884c\u5206\u914d<\/td><\/tr><tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e09\u3001\u4fdd\u6e29\u53ca\u540a\u67b6\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>12\u94dc\u7ba1\u53ca\u4ee5\u4e0b\u539a\u5ea6\u4e3a15mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>16\u94dc\u7ba1\u53ca\u4ee5\u4e0a\u539a\u5ea6\u4e3a20mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr><tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea6\u4e3a15mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u540a\u5361\u4e0e\u652f\u67b6<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u67b6<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u7ba1\u8def\u5b89\u88c5\uff0c\u5347\u7ea7\u5de5\u827a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u56db\u3001\u63a7\u5236\u7cfb\u7edf\u8f85\u6599\u53ca\u4eba\u5de5\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\u7b49<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u8fd0\u8f93\u8d39<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u542b\u8bbe\u5907\u5b89\u88c5\uff0c\u5899\u4f53\u5f00\u5b54\uff0c\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u8d39\u7528\u3002\u8bbe\u5907\u8d28\u4fdd\u671f\u4e3a\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u6574\u673a60\u4e2a\u6708\uff0c6\u4e2a\u6708\u4e3a\u88c5\u4fee\u671f\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u8f85\u6750\u6570\u91cf\u7684\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u571f\u5efa\uff1b\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u5982\u679c\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u8981\u52a8\u7528\u673a\u68b0\u8bbe\u5907\uff0c\u540a\u88c5\u8d39\u7528\u6839\u636e\u60c5\u51b5\u53e6\u8ba1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\u3001\u5ba4\u5185\u673a\u9001\u3001\u56de\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7531\u7532\u65b9\u6728\u5de5\u5f00\u5b54\uff0c\u4e59\u65b9\u8d1f\u8d23\u63d0\u4f9b\u5f00\u5b54\u5c3a\u5bf8\u548c\u5b89\u88c5\uff0c\u98ce\u53e3\u91c7\u7528\u7edf\u4e00\u5c3a\u5bf8\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7\u3001\u65b9\u6848\u6309\u7167\u4fa7\u51fa\u4e0b\u56de\u98ce\u8bbe\u8ba1\uff0c\u5982\u679c\u505a\u4e0b\u51fa\u98ce\uff0c\u6309150\u5143\/\u5e73\u65b9\u7c73\u6210\u54c1\u98ce\u7ba1\u53e6\u8ba1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8\u3001\u62a5\u4ef7\u98ce\u53e3\u6309\u7167\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u5982\u9700\u52a0\u957f\u6309150\u5143\/m\u53e6\u8ba1\uff0c\u4e0d\u8db3\u4e00\u7c73\u6309\u7167\u4e00\u7c73\u8ba1\u7b97\uff0c\u5916\u673a\u7ba1\u9053\u6263\u69fd\u6309100\u5143\/m\u53e6\u8ba1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9\u3001\u5efa\u8bae\u540a\u9876\u4e0d\u505a\u53cd\u5149\u706f\u69fd\uff0c\u53cd\u5149\u706f\u69fd\u5f71\u54cd\u5236\u51b7\u3001\u5236\u70ed\u6548\u679c\uff0c\u8dc3\u5c42\u548c\u5c42\u9ad8\u8d85\u8fc7\u4e09\u7c73\u5236\u70ed\u6548\u679c\u6b20\u4f73\u3002\u5982\u679c\u4fdd\u7559\u706f\u69fd\u8bbe\u8ba1\uff0c\u5efa\u8bae\u4f7f\u7528\u706f\u69fd\u4e13\u7528\u673a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10\u3001\u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a\u4e00\u4e2a\u6708\u3002\u5982\u6709\u9057\u6f0f\uff0c\u53cc\u65b9\u534f\u5546\u3002<\/p>\n\n\n\n<h3 id=\"zl06fl02\" class=\"wp-block-heading\">\u9644\u8868B\uff1a\u65b0\u98ce\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u65e5\u7acb\u5355\u5411\u6d41\u65b0\u98ce\u3001\u4e91\u51c0\u65b0\u98ce\u3001\u4e91\u51c0\u2161\u65b0\u98ce<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u65e5\u7acb<\/td><td>\u5355\u5411\u6d41\u65b0\u98ce<\/td><td><\/td><td><\/td><td>\u5145\u6c9b\u98ce\u91cf\u81ea\u7531\u8c03\u8282\/\u5b81\u9759\u8fd0\u884c\u4e0d\u6270\u7761\u7720\/\u8f7b\u8584\u673a\u8eab\u7075\u6d3b\u5b89\u88c5\/\u6807\u914dRS485\u63a5\u53e3<\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u4e91\u51c0\u65b0\u98ce<\/td><td><\/td><td><\/td><td>\u4e09\u6863\u98ce\u901f\u53ef\u8c03\/\u4e09\u79cd\u6362\u6c14\u65b9\u5f0f\/\u673a\u7ec4\u6807\u914d\u9759\u538b\u8c03\u8282\u677f\/\u667a\u80fd\u8054\u52a8<\/td><\/tr><tr><td>\u65e5\u7acb<\/td><td>\u4e91\u51c0\u2161\u65b0\u98ce<\/td><td><\/td><td><\/td><td>\u5c0f\u5de7\u673a\u8eab\u7075\u6d3b\u5b89\u88c5\/\u9759\u97f3\u8282\u80fd\u8212\u9002\u7701\u7535\/\u667a\u80fd\u63a7\u5236\u5168\u5c4b\u667a\u8054\/\u9ad8\u6548\u51c0\u5316\u5065\u5eb7\u547c\u5438<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>PE\u6ce2\u7eb9\u7ba1<\/td><td>\u03c6110\/\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6750\u8d28\u73af\u4fdd\u65e0\u83cc\/\u6297\u51b2\u51fb\u6027\u548c\u8010\u8150\u8680\u6027\u80fd\u597d<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u4e3b\u673a\u8fde\u63a5\u7ba1<\/td><td>\u03c6110<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5bc6\u5c01\u9632\u5c18\uff0c\u6709\u6548\u964d\u566a<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u76f4\u63a5\/\u53d8\u5f84\/\u4e09\u901a<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u8fde\u63a5\u4ef6<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>PE\u7ba1\u62b1\u5361<\/td><td>\u03c6110\/\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u7ba1<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3<\/td><td>\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>ABS\u4f18\u8d28\u6750\u6599\u65cb\u8f6c\u53ef\u8c03\u8282\/\u7b80\u7ea6\u7cbe\u7f8e<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u98ce\u53e3\u5957\u4ef6<\/td><td>\u03c675<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>ABS\u4f18\u8d28\u6750\u6599\u767d\u8272\u53cc\u5957\u5361\u4ef6\/\u906e\u853d\u5b54\u6d1e<\/td><\/tr><tr><td>\u771f\u5982<\/td><td>\u9632\u96e8\u98ce\u7f69<\/td><td>\u03c6120<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>304\u4e0d\u9508\u94a2\u9632\u96e8\u5916\u98ce\u7f69\u62e6\u622a\u6811\u53f6\u4ee5\u53ca\u6742\u7269<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u65b0\u98ce\u5b89\u88c5\u8c03\u8bd5<\/td><td>\u65b0\u6392\u98ce\u6811\u72b6\u5b89\u88c5<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u6280\u5e08\u56e2\u961f\u670d\u52a1\u6d41\u7a0b\u5347\u7ea7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u65b0\u98ce\u4e3b\u673a\u7684\u7535\u6e90\u7ebf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u65bd\u5de5\u7528\u6c34\u7535\u8d39\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u4e0d\u542b\u5f00\u7968\uff0c\u4e0d\u542b\u8fdc\u7a0b\u8d39\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u4e0d\u542b\u540e\u671f\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7684\u5f00\u53e3\u57fa\u7840\u8d39\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u672c\u62a5\u4ef7\u53ea\u9650\u4e8e\u6b64\u9879\u76ee\u3002<\/p>\n\n\n\n<h3 id=\"zl06fl03\" class=\"wp-block-heading\">\u9644\u8868C\uff1a\u5730\u6696\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u72ec\u7acb\u5730\u6696\u7cfb\u7edf\uff08\u71c3\u6c14\u58c1\u6302\u7089\u6216\u7a7a\u6c14\u80fd\u70ed\u6e90\uff09<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u4e3b\u7ba1\u7cfb\u7edf<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>F-PPR\u7ea4\u7ef4\u590d\u5408\u7ba1<\/td><td>De32<em>4.4\/De40<\/em>5.5\/De50*6.9<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d832\/\u00d840\/\u00d850<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u6e29\u7ba1\/\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d825<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29\uff0c\u964d\u4f4e\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PPR\u89d2\u5f0f\u7403\u9600<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u5206\u96c6\u6c34\u5668\u6c34\u6d41\uff0c\u65b9\u4fbf\u68c0\u4fee<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u94dc\u8d28\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\uff0c\u5206\u8def\u63a7\u5236<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668\u672b\u7aef\u5c3e\u4ef6<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14\u9600+\u6cc4\u6c34\u9600+\u538b\u529b\u8868<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\uff0c\u76f4\u63a5\uff0c\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053\u4e0e\u9600\u95e8<\/td><\/tr><tr><td>\u5a01\u5c14\u9f99<\/td><td>\u6c34\u529b\u5206\u538b\u5668<\/td><td>DN25<\/td><td>1\u9879<\/td><td>\u5f53\u5730\u6696\u505a\u4e8c\u6b21\u7cfb\u7edf\u65f6\uff0c\u9700\u642d\u914d<\/td><\/tr><tr><td>\u5fb7\u56fd\u5a01\u4e50<\/td><td>\u6c34\u6cf5<\/td><td>Wilo-RS25\/8<\/td><td>1\u9879<\/td><td>\u5f53\u5730\u6696\u505a\u4e8c\u6b21\u7cfb\u7edf\u65f6\uff0c\u9700\u642d\u914d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u76d8\u7ba1\u7cfb\u7edf<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1dn20(\u9ed8\u8ba4)<\/td><td>PE-RT dn20*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u4e94\u5c42\u963b\u6c27\u5730\u6696\u7ba1dn20(\u53ef\u9009)<\/td><td>PE-RT dn20*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1dn16(\u53ef\u9009)<\/td><td>PE-RT dn16*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u4e94\u5c42\u963b\u6c27\u5730\u6696\u7ba1dn16(\u53ef\u9009)<\/td><td>PE-RT dn16*en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c(\u53ef\u9009)<\/td><td>\u7eaf\u94dd\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u7eff\u7fbd<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6599<\/td><td>\u9002\u914d\u89c4\u683c<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5ef6\u5899\u4fdd\u6e29\u6761\/\u4f38\u7f29\u7f1d\/\u62a4\u5957\u7ba1\/\u94dd\u7b94\u80f6\u5e26\/\u80f6\u6c34\/\u5361\u9489<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u5f2f\u7ba1\u5957<\/td><td>\u00d820\/\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5206\u96c6\u6c34\u5668\u5730\u6696\u5f2f\u7ba1\u5904\u4fdd\u62a4<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b\u6750\u6599\u4e00\u5957<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u68c0\u6d4b\u7cfb\u7edf\u538b\u529b<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6c34\u6ce5\u7802\u6d46<\/td><td>\/<\/td><td>\/<\/td><td>\u4e3b\u7ba1\u5f00\u69fd\u540e\u8986\u76d6\u4fee\u8865(\u82e5\u6709)\uff0c\u8ddf\u4e1a\u4e3b\u534f\u5546\u7531\u4e1a\u4e3b\u63d0\u4f9b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e09\u3001\u63a7\u5236\u7cfb\u7edf\u4e00(\u9ed8\u8ba4)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u9505\u7089\u63a7\u5236\u5668<\/td><td><\/td><td><\/td><td>\u5730\u6696\u603b\u63a7\u7cfb\u7edf<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u5ba4\u6e29\u63a7\u5236\u5668<\/td><td>RT1.23i<\/td><td>\u4e0e\u623f\u95f4\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u6c34\u91c7\u6696+\u8054\u52a8+WiFi<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>SEH35.23<\/td><td>\u4e0e\u56de\u8def\u6570\u76f8\u540c<\/td><td>AC220V\uff0c\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>3*0.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u6e29\u63a7\u5668\/\u7535\u70ed\u6267\u884c\u5668\/\u9505\u7089<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>PVC\u7ebf\u7ba1<\/td><td>\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u53ca\u7535\u6e90\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u8054\u52a8\u63a7\u5236(\u9ed8\u8ba4)<\/td><td>H-BOX<\/td><td>1\u9879<\/td><td>\u5ba4\u6e29\u8054\u52a8\u9505\u7089\u542f\u505c\uff0c\u8fbe\u5230\u8282\u80fd\u7684\u6548\u679c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e09\u3001\u63a7\u5236\u7cfb\u7edf\u4e8c(\u53ef\u9009)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u9505\u7089\u63a7\u5236\u5668<\/td><td>BELL1 MF<\/td><td>1<\/td><td>\u6e29\u5ea6\u8054\u52a8\u9505\u7089\u542f\u505c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u56db\u3001\u670d\u52a1\u4fdd\u969c<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\/\u51fa\u56fe\/\u5b9a\u4f4d\/\u6d3e\u5355\u7b49<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u76d1\u7406\u670d\u52a1\uff0c\u5305\u62ec\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr><tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u9505\u7089\u6240\u9700\u7684\u6c34\u3001\u7535\u3001\u6c14\u63a5\u53e3\uff0c\u987b\u7531\u4e1a\u4e3b\u8d1f\u8d23\u534f\u8c03\u71c3\u6c14\u3001\u88c5\u9970\u516c\u53f8\u9884\u7559\u5230\u4e09\u65b9\u73b0\u573a\u4ea4\u5e95\u540e\u7684\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u672c\u9884\u7b97\u4e0d\u5305\u542b\u539f\u59cb\u5730\u9762\uff08\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm\uff09\u3001\u5899\u9762\u5904\u7406\u3002\u5982\u9700\u91cd\u63ed\u5730\u576a\u3001\u627e\u5e73\u3001\u8c03\u9ad8\u5dee\u3001\u5783\u573e\u6e05\u8fd0\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u9505\u7089\u70df\u7ba1\u6807\u914d\u4e3a0.8\u7c73\uff0c\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u4e3a\u786e\u4fdd\u9505\u7089\u5b89\u5168\u8fd0\u884c\uff0c\u6240\u9700\u52a0\u957f\u70df\u7ba1\uff0c\u5f2f\u5934\u7b49\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u6696\u6c14\u7247\u5b89\u88c5\u8fc7\u7a0b\u4e2d\u5982\u9700\u589e\u52a0\u5730\u652f\u67b6\uff0c\u8be5\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u536b\u751f\u95f4\uff0c\u53a8\u623f\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u82e5\u94fa\u8bbe\u6709\u91c7\u6696\u7ba1\u9053\uff0c\u9700\u8981\u5728\u5730\u6696\u4e0a\u53ca\u5730\u6696\u4e0b\u5de5\u4f5c\u4e24\u6b21\u9632\u6c34\u3002\u9632\u6c34\u8d39\u7528\u4e0d\u5305\u542b\u5728\u672c\u9884\u7b97\u8303\u56f4\u5185\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\u3001\u975e\u6211\u53f8\u539f\u56e0\u9020\u6210\u66f4\u6539\u5df2\u7ecf\u5b89\u88c5\u597d\u7684\u9505\u7089\u3001\u6696\u6c14\u7247\u3001\u5206\u6c34\u7bb1\u3001\u7ba1\u9053\u4f4d\u7f6e\uff0c\u9700\u53e6\u884c\u6536\u53d6\u76f8\u5173\u6539\u52a8\u8d39\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7\u3001\u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8\u3001\u672c\u9884\u7b97\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/p>\n\n\n\n<h3 id=\"zl06fl04\" class=\"wp-block-heading\">\u9644\u8868D\uff1a\u6697\u57cb\u6696\u6c14\u7247\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u7ae0\u9c7c\u5f0f\u6697\u88c5\u6696\u6c14\u7247\u7cfb\u7edf<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u7ba1\u9053\u4e0e\u8f85\u6750<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>F-PPR\u7ea4\u7ef4\u590d\u5408\u7ba1<\/td><td>De25<em>3.5\/De32<\/em>4.4\/De40<em>5.5\/De50<\/em>6.9<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u94dd\u5851\u590d\u5408\u7ba1<\/td><td>De16*2.2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5206\u96c6\u6c34\u5668\u5230\u6696\u6c14\u7247\u652f\u7ba1<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d825\/\u00d832\/\u00d840\/\u00d850<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u6e29\u7ba1\/\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u652f\u7ba1\u4fdd\u6e29<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>PPR\u89d2\u5f0f\u7403\u9600<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u5206\u96c6\u6c34\u5668\u6c34\u6d41\uff0c\u65b9\u4fbf\u68c0\u4fee<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\uff0c\u5206\u8def\u63a7\u5236<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u5206\u96c6\u6c34\u5668\u672b\u7aef\u5c3e\u4ef6<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14\u9600+\u6cc4\u6c34\u9600+\u538b\u529b\u8868<\/td><\/tr><tr><td>\u5a01\u5c14\u9f99<\/td><td>\u9002\u914d\u5668<\/td><td>16<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u4ef6\u63a5\u5934<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\uff0c\u76f4\u63a5\uff0c\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053\u4e0e\u9600\u95e8<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u5f2f\u7ba1\u5957<\/td><td>\u00d820<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5206\u96c6\u6c34\u5668\u5730\u6696\u5f2f\u7ba1\u5904\u4fdd\u62a4<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b\u6750\u6599\u4e00\u5957<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u68c0\u6d4b\u7cfb\u7edf\u538b\u529b<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6c34\u6ce5\u7802\u6d46<\/td><td>\/<\/td><td>\/<\/td><td>\u5f00\u69fd\u540e\u8986\u76d6\u4fee\u8865\uff0c\u8ddf\u4e1a\u4e3b\u534f\u5546\u7531\u4e1a\u4e3b\u63d0\u4f9b<\/td><\/tr><tr><td>\u5a01\u5c14\u9f99<\/td><td>\u6c34\u529b\u5206\u538b\u5668<\/td><td>DN25<\/td><td>1\u9879<\/td><td>\u5f53\u6696\u6c14\u505a\u4e8c\u6b21\u7cfb\u7edf\u65f6\uff0c\u9700\u642d\u914d<\/td><\/tr><tr><td>\u5fb7\u56fd\u5a01\u4e50<\/td><td>\u6c34\u6cf5<\/td><td>Wilo-RS25\/8<\/td><td>1\u9879<\/td><td>\u5f53\u6696\u6c14\u505a\u4e8c\u6b21\u7cfb\u7edf\u65f6\uff0c\u9700\u642d\u914d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u63a7\u5236\u7cfb\u7edf\u4e00(\u9ed8\u8ba4)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u51ef\u7c73\/\u8d5b\u80fd<\/td><td>\u4f9b\u6c34\u63a7\u5236\u9600<\/td><td>DN15<\/td><td>\u4e0e\u6696\u6c14\u7247\u7ec4\u6570\u76f8\u540c<\/td><td>\u6563\u70ed\u5668\u4f9b\u6c34\u63a7\u5236(\u542b\u7ba1\u9053\u8fde\u63a5\u9002\u914d\u4ef6)<\/td><\/tr><tr><td>\u51ef\u7c73\/\u8d5b\u80fd<\/td><td>\u56de\u6c34\u63a7\u5236\u9600<\/td><td>DN15<\/td><td>\u4e0e\u6696\u6c14\u7247\u7ec4\u6570\u76f8\u540c<\/td><td>\u6563\u70ed\u5668\u56de\u6c34\u63a7\u5236(\u542b\u7ba1\u9053\u8fde\u63a5\u9002\u914d\u4ef6)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u63a7\u5236\u7cfb\u7edf\u4e8c(\u53ef\u9009)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u9505\u7089\u63a7\u5236\u5668<\/td><td>BELL1 MF<\/td><td>1\u4e2a<\/td><td>\u6e29\u5ea6\u8054\u52a8\u9505\u7089\u542f\u505c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u63a7\u5236\u7cfb\u7edf\u4e09(\u53ef\u9009)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u5ba4\u6e29\u63a7\u5236\u5668<\/td><td>RT1.23i<\/td><td>\u4e0e\u623f\u95f4\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u6c34\u91c7\u6696+\u8054\u52a8+WiFi<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>SEH35.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>AC220V\uff0c\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>3*0.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u6e29\u63a7\u5668\/\u7535\u70ed\u6267\u884c\u5668\/\u9505\u7089<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>PVC\u7ebf\u7ba1<\/td><td>\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u53ca\u7535\u6e90\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u8054\u52a8\u63a7\u5236(\u9ed8\u8ba4)<\/td><td>H-BOX<\/td><td>1\u9879<\/td><td>\u5ba4\u6e29\u8054\u52a8\u9505\u7089\u542f\u505c\uff0c\u8fbe\u5230\u8282\u80fd\u7684\u6548\u679c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u9505\u7089\u6240\u9700\u7684\u6c34\u3001\u7535\u3001\u6c14\u63a5\u53e3\uff0c\u987b\u7531\u4e1a\u4e3b\u8d1f\u8d23\u534f\u8c03\u71c3\u6c14\u3001\u88c5\u9970\u516c\u53f8\u9884\u7559\u5230\u4e09\u65b9\u73b0\u573a\u4ea4\u5e95\u540e\u7684\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u672c\u9884\u7b97\u4e0d\u5305\u542b\u539f\u59cb\u5730\u9762(\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm)\u548c\u5899\u9762\u5904\u7406\u3002\u5982\u9700\u91cd\u63ed\u5730\u576a\u3001\u627e\u5e73\u3001\u8c03\u9ad8\u5dee\u3001\u5783\u573e\u6e05\u8fd0\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u9505\u7089\u70df\u7ba1\u6807\u914d\u4e3a0.8\u7c73\uff0c\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u4e3a\u786e\u4fdd\u9505\u7089\u5b89\u5168\u8fd0\u884c\uff0c\u6240\u9700\u52a0\u957f\u70df\u7ba1\uff0c\u5f2f\u5934\u7b49\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u6696\u6c14\u7247\u5b89\u88c5\u8fc7\u7a0b\u4e2d\u5982\u9700\u589e\u52a0\u5730\u652f\u67b6\uff0c\u8be5\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u536b\u751f\u95f4\uff0c\u53a8\u623f\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u82e5\u94fa\u8bbe\u6709\u91c7\u6696\u7ba1\u9053\uff0c\u9700\u8981\u5728\u5730\u6696\u4e0a\u53ca\u5730\u6696\u4e0b\u5de5\u4f5c\u4e24\u6b21\u9632\u6c34\u3002\u9632\u6c34\u8d39\u7528\u4e0d\u5305\u542b\u5728\u672c\u9884\u7b97\u8303\u56f4\u5185\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\u3001\u975e\u6211\u53f8\u539f\u56e0\u9020\u6210\u66f4\u6539\u5df2\u7ecf\u5b89\u88c5\u597d\u7684\u9505\u7089\u3001\u6696\u6c14\u7247\u3001\u5206\u6c34\u7bb1\u3001\u7ba1\u9053\u4f4d\u7f6e\uff0c\u9700\u53e6\u884c\u6536\u53d6\u76f8\u5173\u6539\u52a8\u8d39\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7\u3001\u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8\u3001\u672c\u9884\u7b97\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/p>\n\n\n\n<h3 id=\"zl06fl05\" class=\"wp-block-heading\">\u9644\u8868E\uff1a\u660e\u88c5\u6696\u6c14\u7247\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u5df2\u88c5\u4fee\u623f\u5c4b\u660e\u88c5\u6696\u6c14\u7247\u7cfb\u7edf<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u7ba1\u9053\u4e0e\u8f85\u6750<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f\/\u7d22\u5170\u5fb7<\/td><td>\u94dd\u5851\u590d\u5408\u7ba1<\/td><td>De25<em>3.5\/De32<\/em>4.4<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4f1f\u661f\/\u7d22\u5170\u5fb7<\/td><td>\u94dd\u5851\u590d\u5408\u7ba1<\/td><td>De16*2.3<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u652f\u7ba1\uff1a\u8010\u9ad8\u6e29\u3001\u9632\u6e17\u6c27\uff0c\u7cfb\u7edf\u8fde\u63a5<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d825\/\u00d832<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u6e29\u7ba1\/\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4e3d\u9a6c\/\u534e\u7f8e<\/td><td>\u4fdd\u6e29\u7ba1<\/td><td>\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u652f\u7ba1\u9053\u4fdd\u6e29\uff0c\u964d\u4f4e\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr><tr><td>\u4f1f\u661f\/\u7d22\u5170\u5fb7<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\uff0c\u76f4\u63a5\uff0c\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053\u4e0e\u9600\u95e8<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6263\u69fd<\/td><td>40*80\u5f27\u5f62\u6263\u69fd<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u62a4\uff0c\u7f8e\u89c2<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b\u6750\u6599\u4e00\u5957<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u68c0\u6d4b\u7cfb\u7edf\u538b\u529b<\/td><\/tr><tr><td>\u5a01\u5c14\u9f99<\/td><td>\u6c34\u529b\u5206\u538b\u5668<\/td><td>DN25<\/td><td><\/td><td>\u6696\u6c14\u4e8c\u6b21\u4fa7\u7cfb\u7edf\u4e00\u5957<\/td><\/tr><tr><td>\u5fb7\u56fd\u5a01\u4e50<\/td><td>\u6c34\u6cf5<\/td><td>Wilo-RS25\/8<\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u63a7\u5236\u7cfb\u7edf\u4e00(\u9ed8\u8ba4)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u51ef\u7c73\/\u8d5b\u80fd<\/td><td>\u4f9b\u6c34\u63a7\u5236\u9600<\/td><td>DN15<\/td><td>\u4e0e\u6696\u6c14\u7247\u7ec4\u6570\u76f8\u540c<\/td><td>\u6563\u70ed\u5668\u4f9b\u6c34\u63a7\u5236(\u542b\u7ba1\u9053\u8fde\u63a5\u9002\u914d\u4ef6)<\/td><\/tr><tr><td>\u51ef\u7c73\/\u8d5b\u80fd<\/td><td>\u56de\u6c34\u63a7\u5236\u9600<\/td><td>DN15<\/td><td>\u4e0e\u6696\u6c14\u7247\u7ec4\u6570\u76f8\u540c<\/td><td>\u6563\u70ed\u5668\u56de\u6c34\u63a7\u5236(\u542b\u7ba1\u9053\u8fde\u63a5\u9002\u914d\u4ef6)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u63a7\u5236\u7cfb\u7edf\u4e8c(\u53ef\u9009)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u9505\u7089\u63a7\u5236\u5668<\/td><td>BELL1 MF<\/td><td>1\u4e2a<\/td><td>\u6e29\u5ea6\u8054\u52a8\u9505\u7089\u542f\u505c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u63a7\u5236\u7cfb\u7edf\u4e09(\u53ef\u9009)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\u548c\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u5ba4\u6e29\u63a7\u5236\u5668<\/td><td>RT1.23i<\/td><td>\u4e0e\u623f\u95f4\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u6c34\u91c7\u6696+\u8054\u52a8+WiFi<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>SEH35.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>AC220V\uff0c\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>3*0.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u6e29\u63a7\u5668\/\u7535\u70ed\u6267\u884c\u5668\/\u9505\u7089<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>PVC\u7ebf\u7ba1<\/td><td>\u00d816<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u53ca\u7535\u6e90\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u8054\u52a8\u63a7\u5236(\u9ed8\u8ba4)<\/td><td>H-BOX<\/td><td>1\u9879<\/td><td>\u5ba4\u6e29\u8054\u52a8\u9505\u7089\u542f\u505c\uff0c\u8fbe\u5230\u8282\u80fd\u7684\u6548\u679c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u9505\u7089\u6240\u9700\u7684\u6c34\u3001\u7535\u3001\u6c14\u63a5\u53e3\uff0c\u987b\u7531\u4e1a\u4e3b\u8d1f\u8d23\u534f\u8c03\u71c3\u6c14\u3001\u88c5\u9970\u516c\u53f8\u9884\u7559\u5230\u4e09\u65b9\u73b0\u573a\u4ea4\u5e95\u540e\u7684\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u672c\u9884\u7b97\u4e0d\u5305\u542b\u539f\u59cb\u5730\u9762(\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm)\u548c\u5899\u9762\u5904\u7406\u3002\u5982\u9700\u91cd\u63ed\u5730\u576a\u3001\u627e\u5e73\u3001\u8c03\u9ad8\u5dee\u3001\u5783\u573e\u6e05\u8fd0\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u9505\u7089\u70df\u7ba1\u6807\u914d\u4e3a0.8\u7c73\uff0c\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u4e3a\u786e\u4fdd\u9505\u7089\u5b89\u5168\u8fd0\u884c\uff0c\u6240\u9700\u52a0\u957f\u70df\u7ba1\uff0c\u5f2f\u5934\u7b49\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u56e0\u73b0\u573a\u5ba2\u89c2\u6761\u4ef6\u9650\u5236\uff0c\u6696\u6c14\u7247\u5b89\u88c5\u8fc7\u7a0b\u4e2d\u5982\u9700\u589e\u52a0\u5730\u652f\u67b6\uff0c\u8be5\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u536b\u751f\u95f4\uff0c\u53a8\u623f\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u82e5\u94fa\u8bbe\u6709\u91c7\u6696\u7ba1\u9053\uff0c\u9700\u8981\u5728\u5730\u6696\u4e0a\u53ca\u5730\u6696\u4e0b\u5de5\u4f5c\u4e24\u6b21\u9632\u6c34\u3002\u9632\u6c34\u8d39\u7528\u4e0d\u5305\u542b\u5728\u672c\u9884\u7b97\u8303\u56f4\u5185\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\u3001\u975e\u6211\u53f8\u539f\u56e0\u9020\u6210\u66f4\u6539\u5df2\u7ecf\u5b89\u88c5\u597d\u7684\u9505\u7089\u3001\u6696\u6c14\u7247\u3001\u5206\u6c34\u7bb1\u3001\u7ba1\u9053\u4f4d\u7f6e\uff0c\u9700\u53e6\u884c\u6536\u53d6\u76f8\u5173\u6539\u52a8\u8d39\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7\u3001\u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8\u3001\u672c\u9884\u7b97\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/p>\n\n\n\n<h3 id=\"zl06fl06\" class=\"wp-block-heading\">\u9644\u8868F\uff1a\u6c34\u673a\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u7cfb\u5217\uff08\u5929\u6c34\u5730\u6c34\uff09<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u7a7a\u8c03\u98ce\u7cfb\u7edf\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u7b49\u4e8e\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u7a7a\u8c03\u6c34\u7cfb\u7edf\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u6c34\u673a\u7a7a\u8c03\u4e13\u7528\u7ba1(\u4e3b\u7ba1)<\/td><td>dn40<em>en3.7\/dn50<\/em>en4.6\/dn63*en5.8<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>F-PPRCT\u6c34\u673a\u7a7a\u8c03\u4e13\u7528\u7ba1(\u652f\u7ba1)<\/td><td>dn32<em>en2.9\/dn25<\/em>en2.3<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u8fd0\u8f93\u7ba1\u9053\u4f20\u9012\u51b7\u91cf\u6216\u70ed\u91cf<\/td><\/tr><tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u4e3b\u7ba1)<\/td><td>\u03c640<em>20\/\u03c650<\/em>20\/\u03c663*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9\/\u7ba1\u9053\u4fdd\u6e29\u9632\u6b62\u7ed3\u9732<\/td><\/tr><tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u652f\u7ba1)<\/td><td>\u03c632<em>20\/\u03c625<\/em>20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29\u9632\u6b62\u7ed3\u9732<\/td><\/tr><tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>UPVC\u51b7\u51dd\u6c34\u7ba1\u53ca\u4fdd\u6e29\u8f85\u6599<\/td><td>\u9002\u914d\u578b\u53f7<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u653e\u51b7\u51dd\u6c34\uff0c\u9632\u6b62\u7ed3\u9732<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\u3001\u76f4\u63a5\u3001\u5927\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ba1\u9053<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7403\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u6d3b\u63a5\u9600\u95e8\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u622a\u6b62\u9600<\/td><td>DN32<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td><\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u4e8c\u901a\u9600\uff08\u9632\u7ed3\u57a2\u9632\u6c34\uff09<\/td><td>FK30.20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5207\u65ad\u672b\u7aef\u6c34\u6d41\uff0c\u5206\u533a\u8c03\u8282<\/td><\/tr><tr><td>\u65e5\u7acb\u6807\u914d<\/td><td>\u5b89\u5168\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7cfb\u7edf\u6c34\u538b\uff0c\u907f\u514d\u8bbe\u5907\u9600\u95e8\u53d7\u9ad8\u538b\u635f\u574f<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>DN32<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a\u548c\u7cfb\u7edf\u6700\u5c0f\u5faa\u73af\u6d41\u91cf<\/td><\/tr><tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u81ea\u52a8\u8865\u6c34\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u8bc1\u7cfb\u7edf\u6c34\u91cf\u5145\u8db3\u63d0\u9ad8\u6548\u7387<\/td><\/tr><tr><td>\u65e5\u7acb\u6807\u914d<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fc7\u6ee4\u6742\u8d28\uff0c\u4fdd\u8bc1\u7cfb\u7edf\u6b63\u5e38\u8fd0\u884c<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u91d1\u5c5e\u6ce2\u7eb9\u7ba1<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u7ba1\u9053\uff0c\u51cf\u9707\uff0c\u907f\u514d\u5bf9\u7ba1\u9053\u9600\u95e8\u4ea7\u751f\u9707\u52a8\u53d1\u58f0<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u91d1\u5c5e\u6ce2\u7eb9\u7ba1<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td><\/td><\/tr><tr><td>\u65bd\u8010\u5fb7<\/td><td>\u7ee7\u7535\u5668<\/td><td>RXM<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6c34\u6cf5\u4e2d\u7ee7\u63a7\u5236<\/td><\/tr><tr><td>\u65b0\u6caa\/\u65b0\u754c<\/td><td>\u53d8\u9891\u6c34\u6cf5<\/td><td>\u578b\u53f7\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u53d8\u9891\u7cfb\u7edf\u4e00\u5957<\/td><\/tr><tr><td>\/<\/td><td>\u81a8\u80c0\u7f50<\/td><td>8L<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5438\u7eb3\u7cfb\u7edf\u4e2d\u7684\u6c34\u53d7\u70ed\u540e\u589e\u52a0\u7684\u4f53\u79ef<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u8bbe\u5907\u914d\u4ef6<\/td><td>\u6e29\u538b\u8868\/\u6d3b\u63a5\/\u8865\u82af\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u4ef6\/\u4fbf\u4e8e\u68c0\u67e5\u7cfb\u7edf\u8fd0\u884c\u72b6\u51b5<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u540a\u5361\uff08\u914d\u62b1\u7b8d\uff09<\/td><td>\u9002\u914d\u578b\u53f7<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u51b7\u5a92\u7ba1\u548c\u51b7\u51dd\u7ba1<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u8f85\u6750<\/td><td>\u751f\u6599\u5e26\u3001\u4e1d\u6746\u3001\u578b\u94a2\u3001\u81a8\u80c0\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u56fa\u5b9a\u7ba1\u9053\u4e0e\u8bbe\u5907<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e09\u3001\u7a7a\u8c03\u7535\u63a7\u7cfb\u7edf\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u7f8e\u6cb3<\/td><td>RVVP<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u7ebf\u63a7\u5668\u4e0e\u5185\u673a\u4e4b\u95f4\u901a\u8baf<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>RVVP<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u5185\u673a\u4e4b\u95f4\u5230\u5916\u673a\u901a\u8baf<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>BV<\/td><td>3*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5185\u673a\u7535\u6e90\u7ebf<\/td><\/tr><tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>PVC\u7ebf\u7ba1\u53ca\u914d\u4ef6<\/td><td>\u03c616<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u53ca\u7535\u6e90\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u56db\u3001\u91c7\u6696\u7cfb\u7edf\u63a7\u5236\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c42\u697c\u4e00\u4e2a<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\u3001\u5206\u8def\u63a7\u5236\uff0c\u6392\u6c14\u6392\u6c61\u9600\u4fbf\u4e8e\u7cfb\u7edf\u68c0\u4fee\u548c\u7ef4\u62a4<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u9002\u914d\u4e00\u4f53\u89d2\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5916\u4e1d\u5bf9\u63a5<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u9600\u95e8\u4e0e\u8bbe\u5907<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u4e8c\u901a\u9600<\/td><td>FK30.20<\/td><td>\u6bcf\u5c42\u697c\u4e00\u4e2a<\/td><td>\u5207\u65ad\u672b\u7aef\u6c34\u6d41\uff0c\u8d77\u5230\u7cfb\u7edf\u8282\u80fd\u548c\u9632\u6b62\u51b7\u6c34\u8fdb\u5165\u5730\u9762\u9020\u6210\u7ed3\u9732<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e94\u3001\u91c7\u6696\u7cfb\u7edf\u5730\u9762\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c(\u53ef\u9009)<\/td><td>\u7eaf\u94dd\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u7eff\u7fbd<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td><\/tr><tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u8f85\u6599<\/td><td>\u5361\u9489.\u767d\u4e73\u80f6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u56fa\u5b9a\u5730\u6696\u76d8\u7ba1\u548c\u53cd\u5c04\u819c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u516d\u3001\u670d\u52a1\u4fdd\u969c<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d\u7b49<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u76d1\u7406\u670d\u52a1\uff0c\u5305\u62ec\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr><tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u7a7a\u8c03\u914d\u7535\u7bb1\u3001\u4ee5\u53ca\u4ece\u4e3b\u673a\u5230\u914d\u7535\u7bb1\u7684\u7535\u6e90\u7ebf\uff0c\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u7a7a\u8c03\u68c0\u4fee\u53e3\u7531\u88c5\u4fee\u4e13\u4e1a\u8d1f\u8d23\u5f00\u53e3\u4e14\u68c0\u4fee\u53e3\u7531\u88c5\u9970\u4e13\u4e1a\u5236\u4f5c\u5b89\u88c5\uff0c\u6240\u6709\u7684\u5c3a\u5bf8\u5747\u7531\u6211\u516c\u53f8\u73b0\u573a\u65bd\u5de5\u4eba\u5458\u63d0\u4f9b\u3002\u5982\u9700\u66f4\u6539\u98ce\u53e3\u5c3a\u5bf8\u9700\u53e6\u884c\u8ba1\u8d39\uff1a150\u5143\/\u7c73\u3002\u88c5\u9970\u6263\u69fd\uff1a110\u5143\/\u7c73\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u88c5\u4fee\u65b9\u8d1f\u8d23\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03\u6c34\u7cfb\u7edf\u8865\u6c34\uff0c\u5373\u63d0\u4f9b\u4e00\u6839\u81ea\u6765\u6c34\u7ba1\u5e76\u52a0\u88c5\u9600\u95e8\u81f3\u6211\u65b9\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u7532\u65b9\u8d1f\u8d23\u4e3b\u673a\u57fa\u7840\uff0c\u62a5\u4ef7\u4e0d\u5305\u542b\u8bbe\u5907\u7684\u540a\u88c5\u8d39\uff0c\u5982\u6709\u9700\u8981\u8d39\u7528\u6309\u516c\u53f8\u6536\u8d39\u6807\u51c6\u6536\u53d6\uff0c\u6216\u7532\u65b9\u81ea\u884c\u540a\u88c5\u81f3\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u7a7a\u8c03\u5185\u673a\u5b89\u88c5\u98ce\u53e3\u51fa\u98ce\u65b9\u5f0f\u4e3a\u4fa7\u51fa\u4e0b\u56de\uff0c\u5982\u9700\u589e\u52a0\u98ce\u9053\u6309\u6bcf\u5e73\u65b9150\u5143\u53e6\u884c\u8ba1\u7b97\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\u3001\u5730\u6696\uff1a\u6309\u7167\u7532\u65b9\u8981\u6c42\u8bbe\u8ba1\uff1b\u5ba4\u6e29\u8bbe\u8ba1\u4f9d\u636e18\u2103~22\u2103\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7\u3001\u672c\u9884\u7b97\u4e0d\u5305\u542b\u539f\u59cb\u5730\u9762(\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm)\u548c\u5899\u9762\u5904\u7406\u53ca\u84c4\u70ed\u5c42\u3002\u5982\u9700\u91cd\u63ed\u5730\u576a\uff0c\u627e\u5e73\uff0c\u8c03\u9ad8\u5dee\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8\u3001\u536b\u751f\u95f4\u3001\u53a8\u623f\u3001\u9633\u53f0\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u623f\u5c4b\uff0c\u5982\u9700\u5b89\u88c5\u7ba1\u8def\u53ca\u5206\u6c34\u7bb1\u7b49\u91c7\u6696\u8bbe\u5907\uff0c\u5219\u623f\u5c4b\u5730\u9762\u7684\u9632\u6c34\u7531\u7532\u65b9\u8d1f\u8d23\u91cd\u505a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9\u3001\u5982\u91c7\u7528\u6728\u5730\u677f\u65f6\uff0c\u4e00\u5b9a\u4e0d\u8981\u94fa\u8bbe\u9632\u6f6e\u57ab\uff0c\u5426\u5219\u5f71\u54cd\u5730\u6696\u6563\u70ed\u6548\u679c\u7531\u7532\u65b9\u6216\u6728\u5730\u677f\u65bd\u5de5\u65b9\u8d1f\u8d23\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u7a0e\u91d1\u3001\u8fdc\u7a0b\u65bd\u5de5\u8d39\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">11\u3001\u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">12\u3001\u672c\u9884\u7b97\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/p>\n\n\n\n<h3 id=\"zl06fl07\" class=\"wp-block-heading\">\u9644\u8868G\uff1a\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9002\u7528\u7cfb\u7edf<\/strong>\uff1a\u65e5\u7acb\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u7a7a\u8c03\u98ce\u7cfb\u7edf\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u5b9a\u5236<\/td><td>\u51fa\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u4e0e\u8bbe\u5907\u51fa\u98ce\u53e3\u957f\u5ea6\u76f8\u540c<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4fa7\u9001\u98ce<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u56de\u98ce\u53e3\uff1aABS\u9632\u7ed3\u9732\u767e\u53f6<\/td><td>\u7b49\u4e8e\u8bbe\u5907\u56de\u98ce+\u68c0\u4fee\u957f\u5ea6<\/td><td>\u4e0e\u5185\u673a\u53f0\u6570\u76f8\u540c(\u4e2a)<\/td><td>\u4e0b\u56de\u98ce\u5e26\u68c0\u4fee<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u98ce\u53e3\u8f6f\u63a5<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u8fde\u63a5\u8bbe\u5907\u4e0e\u98ce\u53e3\u6216\u98ce\u9053<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u8f85\u6750<\/td><td>\u80f6\u6c34\u3001\u5237\u5b50\u3001\u540a\u7b4b\u3001\u87ba\u4e1d\u7b49<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u98ce\u53e3\u3001\u8f6f\u63a5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u7a7a\u8c03\u7ba1\u8def\u7cfb\u7edf\u53ca\u8f85\u6599\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1(\u7ba1\u5f84\u00d7\u58c1\u539amm)<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>TP2\u9ad8\u54c1\u8d28\u3001\u53bb\u6cb9\u94dc\u7ba1\uff0c\u5bf9\u51b7\u5a92\u8fdb\u884c\u8f93\u9001<\/td><\/tr><tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5bf9\u51b7\u5a92\u8fdb\u884c\u5206\u914d<\/td><\/tr><tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>R410A\u65b0\u51b7\u5a92<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e09\u3001\u7a7a\u8c03\u7ba1\u8def\u4fdd\u6e29\u53ca\u540a\u67b6\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>12\u94dc\u7ba1\u53ca\u4ee5\u4e0b\u539a\u5ea6\u4e3a15mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>16\u94dc\u7ba1\u53ca\u4ee5\u4e0a\u539a\u5ea6\u4e3a20mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr><tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea6\u4e3a15mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u51cf\u5c11\u51b7\u91cf\/\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u7f8e\u7279\u745e\u65af<\/td><td>\u51b7\u51dd\u6c34\u7ba1\u4fdd\u6e29\u68c9(\u53ef\u9009)<\/td><td>\u539a\u5ea69mm<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u9632\u6b62\u51dd\u9732<\/td><\/tr><tr><td>\u5b9a\u5236<\/td><td>\u540a\u5361\u4e0e\u652f\u67b6<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u67b6<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u7ba1\u8def\u5b89\u88c5\uff0c\u5347\u7ea7\u5de5\u827a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u56db\u3001\u7a7a\u8c03\u63a7\u5236\u7cfb\u7edf\u8f85\u6599\u53ca\u4eba\u5de5\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u5854\u724c<\/td><td>BV\u7535\u6e90\u7ebf<\/td><td>1*2.5mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5185\u673a\u914d\u7535<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>RVVP\u5c4f\u853d\u7ebf<\/td><td>2*0.75mm2<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf<\/td><\/tr><tr><td>\u5ddd\u8def<\/td><td>\u7ebf\u7ba1<\/td><td>dn16<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u63a7\u5236\u5668\u63a5\u7ebf\u7a7f\u7ebf<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u4eba\u5de5<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td>\u5f00\u5b54\/\u5b89\u88c5\u7b49<\/td><\/tr><tr><td>\u9f99\u8109<\/td><td>\u8fd0\u8f93\u8d39<\/td><td>\u9f99\u8109<\/td><td>\u5305\u5de5\u5305\u6599\uff0c\u6839\u636e\u5b9e\u9645<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e94\u3001\u91c7\u6696\u7cfb\u7edf\u4e3b\u7ba1\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>FPPRCT(\u4e3b\u7ba1)<\/td><td>dn32<em>en2.9\/dn40<\/em>en3.7\/dn50*en4.6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4e3b\u7ba1\/\u6839\u636e\u9762\u79ef\u6216\u8d1f\u8377\u5927\u5c0f\u8fdb\u884c\u9009\u62e9<\/td><\/tr><tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u4e3b\u7ba1)<\/td><td>\u03c632<em>20\/\u03c640<\/em>20\/\u03c650*20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6839\u636e\u4e3b\u7ba1\u5927\u5c0f\u8fdb\u884c\u9009\u62e9\/\u7ba1\u9053\u4fdd\u6e29\uff0c\u51cf\u5c11\u70ed\u91cf\u635f\u5931<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c42\u697c\u4e00\u4e2a<\/td><td>\u5b89\u88c5\u56fa\u5b9a\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b\u3001\u5206\u8def\u63a7\u5236\u3001\u6392\u6c14\u6392\u6c61\u9600\u4fbf\u4e8e\u7cfb\u7edf\u68c0\u4fee\u548c\u7ef4\u62a4<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u9002\u914d\u4e00\u4f53\u89d2\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7cfb\u7edf\u7ba1\u4ef6<\/td><td>\u4e09\u901a\uff0c\u76f4\u63a5\uff0c\u5f2f\u5934\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u4e3b\u7ba1\u7ba1\u9053<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u622a\u6b62\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u901a\u65ad\u6c34\u6d41\uff0c\u6d3b\u63a5\u9600\u95e8\u65b9\u4fbf\u540e\u671f\u68c0\u4fee<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u91d1\u5c5e\u6ce2\u7eb9\u7ba1<\/td><td>DN32<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u9707\/\u907f\u514d\u4e3b\u673a\u5bf9\u7ba1\u9053\u9600\u95e8\u4ea7\u751f\u9707\u52a8\u53d1\u58f0<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u5b89\u5168\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7cfb\u7edf\u6c34\u538b\/\u907f\u514d\u8bbe\u5907\u9600\u95e8\u53d7\u9ad8\u538b\u635f\u574f<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a\u548c\u7cfb\u7edf\u6700\u5c0f\u5faa\u73af\u6d41\u91cf<\/td><\/tr><tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u81ea\u52a8\u8865\u6c34\u9600<\/td><td>DN15<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u8bc1\u7cfb\u7edf\u6c34\u91cf\u5145\u8db3\u63d0\u9ad8\u6548\u7387<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6b63\u53d1<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>40\u76ee\uff0c\u8fc7\u6ee4\u6742\u8d28\uff0c\u4fdd\u8bc1\u7cfb\u7edf\u6b63\u5e38\u8fd0\u884c<\/td><\/tr><tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u8bbe\u5907\u914d\u4ef6<\/td><td>\u538b\u529b\u6e29\u5ea6\u8868\/\u5185\u5916\u4e1d\u6d3b\u63a5\u5bf9\u63a5\/\u8865\u82af\u7b49<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fde\u63a5\u9600\u95e8\u7ba1\u4ef6\uff0c\u7a33\u5b9a\u7cfb\u7edf\u8fd0\u884c\uff0c\u663e\u793a\u7cfb\u7edf\u538b\u529b\u4fbf\u4e8e\u68c0\u67e5\u7cfb\u7edf\u8fd0\u884c\u72b6\u51b5<\/td><\/tr><tr><td>\u56fd\u4ea7\u4f18\u8d28<\/td><td>\u6c34\u6ce5\u7802\u6d46<\/td><td><\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5f00\u69fd\u540e\u8986\u76d6\u4fee\u8865\uff0c\u8ddf\u4e1a\u4e3b\u534f\u5546\u7531\u4e1a\u4e3b\u63d0\u4f9b<\/td><\/tr><tr><td>\u8ba2\u8d2d<\/td><td>\u6253\u538b<\/td><td><\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6253\u538b\u6750\u6599\u4e00\u5957<\/td><\/tr><tr><td>\u65b0\u6caa\/\u65b0\u754c<\/td><td>\u53d8\u9891\u6c34\u6cf5<\/td><td>\u578b\u53f7\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5f53\u91c7\u6696\u7cfb\u7edf\u65e0\u81ea\u5e26\u6c34\u6cf5\u65f6\u9009\u914d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u516d\u3001\u91c7\u6696\u7cfb\u7edf\u63a7\u5236\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u65e5\u7acb<\/td><td>\u6c34\u6e29\u63a7\u5236\u5668<\/td><td>PC-WHM2Q\/PC-WHM3Q<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6839\u636e\u4e0d\u540c\u7cfb\u5217\u8981\u6c42\u9009\u914d\uff0c\u8c03\u8282\u91c7\u6696\u6c34\u6e29<\/td><\/tr><tr><td>\u66fc\u745e\u5fb7<\/td><td>\u7535\u70ed\u6267\u884c\u5668<\/td><td>MT20.23<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u5730\u6696\u5404\u56de\u8def\u901a\u65ad<\/td><\/tr><tr><td>\u7f8e\u6cb3<\/td><td>\u63a7\u5236\u7ebf<\/td><td>2*1.5mm\u00b2<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u63a7\u5236\u7ebf<\/td><\/tr><tr><td>\u4f1f\u661f\/\u5ddd\u8def<\/td><td>PVC\u5957\u7ba1<\/td><td>\u03c616<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u63a7\u5236\u7ebf\u4fdd\u62a4\u5957\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e03\u3001\u91c7\u6696\u7cfb\u7edf\u5730\u9762\u90e8\u5206<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4e13\u7528\u70ed\u7ba1<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u7eaf\u94dd\u53cd\u5c04\u819c(\u53ef\u9009)<\/td><td>\u7eaf\u94dd\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr><tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u7eff\u7fbd<\/td><td>\u767d\u6676\u677f(\u53ef\u9009)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u4fdd\u6e29\u677f\uff0c\u51cf\u5c11\u70ed\u91cf\u5411\u4e0b\u6563\u5931<\/td><\/tr><tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u84c4\u70ed\u5c42\u63d0\u9ad8\u91c7\u6696\u8212\u9002\u5ea6<\/td><\/tr><tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u8f85\u6599<\/td><td>\u5361\u9489.\u767d\u4e73\u80f6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u56fa\u5b9a\u5730\u6696\u76d8\u7ba1\u548c\u53cd\u5c04\u819c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u516b\u3001\u670d\u52a1\u4fdd\u969c<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><\/tr><\/thead><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\u3001\u51fa\u56fe\u3001\u5b9a\u4f4d\u7b49<\/td><\/tr><tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u4f1f\u661f\u5382\u5bb6\u63d0\u4f9b\u7b2c\u4e09\u65b9\u76d1\u7406\u670d\u52a1\uff0c\u5305\u62ec\u68c0\u67e5\u3001\u6253\u538b\u53caVR\u5168\u666f<\/td><\/tr><tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4e2d\u56fd\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7531\u9f99\u8109\u3001\u4f1f\u661f\u5382\u5bb6\u53ca\u4e2d\u56fd\u4eba\u4fdd\u63d0\u4f9b50\u5e74\u4ea7\u54c1\u8054\u4fdd\u534f\u8bae<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u8bf4\u660e\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3001\u672c\u62a5\u4ef7\u542b\u8bbe\u5907\u5b89\u88c5\u3001\u5899\u4f53\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u53ca\u8f85\u6750\u8d39\u7528\uff1b\u8bbe\u5907\u8d28\u4fdd\u671f\u4e3a\u8bbe\u5907\u8fdb\u573a66\u4e2a\u6708\uff08\u6574\u673a60\u4e2a\u6708\uff0c6\u4e2a\u6708\u4e3a\u88c5\u4fee\u671f\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3001\u672c\u62a5\u4ef7\u4e2d\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\uff0c\u5408\u540c\u603b\u4ef7\u4e3a\u5305\u5de5\u5305\u6599\u6ee1\u8db3\u8fd0\u884c\u4ea4\u4ed8\uff0c\u8f85\u6750\u6570\u91cf\u7684\u589e\u51cf\u4e0d\u518d\u591a\u9000\u5c11\u8865\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u7a7a\u8c03\u914d\u7535\u7bb1\u3001\u4ee5\u53ca\u4ece\u4e3b\u673a\u5230\u914d\u7535\u7bb1\u7684\u7535\u6e90\u7ebf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\u3001\u672c\u62a5\u4ef7\u4e0d\u542b\u5ba4\u5916\u673a\u57fa\u7840\u3001\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u539f\u59cb\u5730\u9762\uff08\u539f\u59cb\u5730\u9762\u6c34\u5e73\u9ad8\u5dee\u5e94\u5c0f\u4e8e1cm\uff09\u3001\u5899\u9762\u3001\u84c4\u70ed\u5c42\u5904\u7406\uff0c\u5982\u9700\u91cd\u63ed\u5730\u576a\uff0c\u627e\u5e73\uff0c\u8c03\u9ad8\u5dee\u7b49\uff0c\u8d39\u7528\u53e6\u884c\u6536\u53d6\uff1b\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5\u3001\u5982\u679c\u5ba4\u5916\u673a\u5c31\u4f4d\u9700\u8981\u52a8\u7528\u673a\u68b0\u8bbe\u5907\u540a\u88c5\uff0c\u8d39\u7528\u6309\u6211\u516c\u53f8\u6536\u8d39\u6807\u51c6\u6536\u53d6\uff0c\u6216\u7532\u65b9\u81ea\u884c\u540a\u88c5\u81f3\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\u3001\u88c5\u4fee\u65b9\u8d1f\u8d23\u63d0\u4f9b\u4e2d\u592e\u7a7a\u8c03\u6c34\u7cfb\u7edf\u8865\u6c34\uff0c\u5373\u63d0\u4f9b\u4e00\u6839\u81ea\u6765\u6c34\u7ba1\u5e76\u52a0\u88c5\u9600\u95e8\u81f3\u6211\u65b9\u6307\u5b9a\u4f4d\u7f6e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7\u3001\u5ba4\u5185\u673a\u9001\u3001\u56de\u98ce\u53e3\u3001\u68c0\u4fee\u53e3\u7531\u7532\u65b9\u6728\u5de5\u5f00\u5b54\uff0c\u6240\u6709\u7684\u5c3a\u5bf8\u5747\u7531\u6211\u516c\u53f8\u73b0\u573a\u65bd\u5de5\u4eba\u5458\u63d0\u4f9b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8\u3001\u7a7a\u8c03\u5185\u673a\u51fa\u98ce\u65b9\u5f0f\u4e3a\u4fa7\u51fa\u4e0b\u56de\uff0c\u5982\u9700\u589e\u52a0\u98ce\u9053\u6309150\u5143\/\u5e73\u65b9\u7c73\u53e6\u8ba1\uff1b\u98ce\u53e3\u6309\u7167\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u5982\u9700\u52a0\u957f\u6309150\u5143\/m\u53e6\u8ba1\uff0c\u4e0d\u8db3\u4e00\u7c73\u6309\u7167\u4e00\u7c73\u8ba1\u7b97\uff1b\u5916\u673a\u7ba1\u9053\u82e5\u52a0\u88c5\u9970\u6263\u69fd\u6309110\u5143\/m\u53e6\u8ba1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9\u3001\u5730\u6696\u6309\u7167\u7532\u65b9\u8981\u6c42\u8bbe\u8ba1\uff1a\u5ba4\u6e2918\u2103~22\u2103\uff1b\u5730\u6696\u623f\u95f4\u5982\u91c7\u7528\u6728\u5730\u677f\u65f6\uff0c\u9700\u9009\u62e9\u5730\u6696\u4e13\u7528\u6728\u5730\u677f\uff0c\u4e14\u4e00\u5b9a\u4e0d\u8981\u94fa\u8bbe\u9632\u6f6e\u57ab\uff0c\u5426\u5219\u5f71\u54cd\u5730\u6696\u6563\u70ed\u6548\u679c\u7531\u7532\u65b9\u6216\u6728\u5730\u677f\u65bd\u5de5\u65b9\u8d1f\u8d23\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10\u3001\u536b\u751f\u95f4\u3001\u53a8\u623f\u3001\u9633\u53f0\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u82e5\u94fa\u8bbe\u6709\u91c7\u6696\u7ba1\u9053\uff0c\u9700\u8981\u5728\u5730\u6696\u4e0a\u53ca\u5730\u6696\u4e0b\u5de5\u4f5c\u4e24\u6b21\u9632\u6c34\uff1b\u9632\u6c34\u8d39\u7528\u4e0d\u5305\u542b\u5728\u672c\u9884\u7b97\u8303\u56f4\u5185\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">11\u3001\u672c\u62a5\u4ef7\u6709\u6548\u671f30\u5929\uff0c\u672a\u7ecf\u53cc\u65b9\u7b7e\u5b57(\u76d6\u7ae0)\u786e\u8ba4\uff0c\u4e0d\u5177\u5907\u5408\u540c\u6548\u529b\uff0c\u4ec5\u505a\u521d\u6b65\u8bbe\u8ba1\u9636\u6bb5\u4f7f\u7528\u3002<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u7248\u672c<\/strong>\uff1aV2.0 |&nbsp;<strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670822\u65e5 |&nbsp;<strong>\u91cd\u6784\u4f9d\u636e<\/strong>\uff1a\u8f85\u6750\u6e05\u5355 V1.0 \u539f\u6587\uff08520\u884c\u6570\u636e\u8868\uff09\u2192 \u6309\u5341\u6761\u7edf\u4e00\u6a21\u677f\u91cd\u6784\u4e3a\u72ec\u7acb\u6307\u4ee4\uff0c\u9644\u8868\u5f52\u5165\u9644\u5f55<\/p>\n<\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>\u76ee\u5f55 \u4e00\u3001\u6307\u4ee4\u76ee\u6807 \u8ba9DS\u5728\u751f\u6210\u65b9\u6848\u4e66\uff08 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1337","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1337\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u76ee\u5f55 \u4e00\u3001\u6307\u4ee4\u76ee\u6807 \u8ba9DS\u5728\u751f\u6210\u65b9\u6848\u4e66\uff08 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1337\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-23T12:28:44+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1337\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1337\",\"name\":\"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-22T10:12:07+00:00\",\"dateModified\":\"2026-05-23T12:28:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1337#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1337\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1337#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1337","og_locale":"zh_CN","og_type":"article","og_title":"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0 - \u9f99\u8109\u6696\u901a","og_description":"\u76ee\u5f55 \u4e00\u3001\u6307\u4ee4\u76ee\u6807 \u8ba9DS\u5728\u751f\u6210\u65b9\u6848\u4e66\uff08 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=1337","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-23T12:28:44+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1337","url":"https:\/\/longmai-nt.com\/?page_id=1337","name":"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-22T10:12:07+00:00","dateModified":"2026-05-23T12:28:44+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1337#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1337"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1337#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6307\u4ee406\uff1a\u8f85\u6750\u914d\u7f6e\u6e05\u5355 \u2014 DS\u81ea\u52a8\u751f\u6210\u89c4\u5219 V2.0"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1337","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1337"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1337\/revisions"}],"predecessor-version":[{"id":1364,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1337\/revisions\/1364"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1337"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}