{"id":14114,"date":"2026-10-07T15:09:22","date_gmt":"2026-10-07T07:09:22","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=14114"},"modified":"2026-10-14T14:34:41","modified_gmt":"2026-10-14T06:34:41","slug":"%e9%bb%84%e9%be%99%e6%ba%aa%e5%9b%9b%e5%b1%82%e5%88%ab%e5%a2%85%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e6%96%b9%e6%a1%88%e5%85%ac%e5%bc%80%e7%89%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=14114","title":{"rendered":"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248"},"content":{"rendered":"\n<h2>\u4e00\u3001\u5148\u628a\u8fd9\u4efd\u65b9\u6848\u7684\u6765\u9f99\u53bb\u8109\u8bf4\u6e05\u695a<\/h2>\n\n<p>\u8fd9\u662f 2026 \u5e74 10 \u6708\uff0c\u6211\u4eec\u7ed9\u6210\u90fd\u9ec4\u9f99\u6eaa\u4e00\u4f4d\u4e1a\u4e3b\u5bb6\u7684<strong>\u56db\u5c42\u522b\u5885\uff08\u542b\u8d1f\u4e00\u697c\uff0c\u5236\u51b7\u9762\u79ef 141.79 \u33a1\uff09<\/strong>\u505a\u7684\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u65b9\u6848\u3002\u623f\u95f4\u5212\u5206\u3001\u9762\u79ef\u3001\u5185\u673a\u914d\u7f6e\u90fd\u662f\u771f\u5b9e\u7684\uff0c\u4e1a\u4e3b\u59d3\u540d\u548c\u95e8\u724c\u505a\u4e86\u8131\u654f\u5904\u7406\u3002\u540c\u6237\u578b\u7684\u4e1a\u4e3b\u53ef\u4ee5\u62ff\u7740\u8fd9\u4e00\u9875\uff0c\u5bf9\u7740\u4efb\u4f55\u4e00\u5bb6\u7684\u65b9\u6848\u6bd4\u3002<\/p>\n\n<p>\u4e8b\u60c5\u7684\u8d77\u56e0\u662f\uff1a\u4e1a\u4e3b\u628a\u6211\u4eec\u8fd9\u5957\u65b9\u6848\u62ff\u53bb\u95ee\u4e86 AI\uff0cAI \u8bf4\u300c\u914d\u7f6e\u5c0f\u4e86\u300d\u3002\u5230\u5e95\u5c0f\u4e0d\u5c0f\uff0c\u4e0b\u9762\u6309\u8fd9\u5957\u623f\u7684\u771f\u5b9e\u60c5\u51b5\u4e00\u6761\u6761\u7b97\u2014\u2014<strong>\u8fd9\u6237\u4e0d\u505a\u5730\u6696\uff0c\u7a7a\u8c03\u590f\u5929\u8981\u5236\u51b7\u3001\u51ac\u5929\u8fd8\u8981\u62c5\u91c7\u6696<\/strong>\uff0c\u6240\u4ee5\u6211\u4eec\u628a\u5236\u51b7\u548c\u91c7\u6696\u5206\u5f00\u6838\u3002<\/p>\n\n<p><strong>\u9879\u76ee\u8282\u70b9\uff1a<\/strong>\u8fd9\u5957\u623f\u662f<strong>\u7cbe\u88c5\u623f\uff08\u5728\u5efa\uff09<\/strong>\uff0c\u9700\u8981<strong>\u8d76\u5728\u7cbe\u88c5\u88c5\u4fee\u8fdb\u573a\u4e4b\u524d\uff0c\u5148\u628a\u4e2d\u592e\u7a7a\u8c03\u7684\u9690\u853d\u5de5\u7a0b\u505a\u5b8c<\/strong>\u3002\u65b9\u6848\u5b9a\u5f97\u8d8a\u65e9\u3001\u8fdb\u573a\u8d8a\u4ece\u5bb9\u2014\u2014\u4e00\u65e6\u7cbe\u88c5\u5de5\u5e8f\u5f00\u59cb\uff0c\u7ba1\u8def\u548c\u540a\u9876\u518d\u56de\u5934\u6539\u5c31\u9ebb\u70e6\u4e86\u3002\u8fd9\u4e5f\u662f\u6211\u4eec\u5efa\u8bae\u5c3d\u5feb\u52d8\u6d4b\u3001\u5c3d\u5feb\u5b9a\u6848\u7684\u539f\u56e0\u3002<\/p>\n\n<p>\u8bf4\u300c\u914d\u7f6e\u5c0f\u4e86\u300d\u7684\u7406\u7531\u662f\uff1a\u4e0d\u505a\u5730\u6696\uff0c\u51ac\u5929\u8981\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u6240\u4ee5\u53ea\u6309\u5236\u51b7\u914d\u4e0d\u591f\u3002\u8fd9\u4e2a\u63d0\u9192<strong>\u6709\u4e00\u534a\u662f\u5bf9\u7684<\/strong>\u2014\u2014\u786e\u5b9e\u4e0d\u505a\u5730\u6696\uff0c\u7a7a\u8c03\u51ac\u5929\u8981\u5e72\u6d3b\uff0c\u6240\u4ee5\u8981<strong>\u6309\u4e24\u628a\u5c3a\u5b50\u91cf<\/strong>\uff0c\u5fc5\u987b\u505a\u5236\u70ed\u6821\u6838\u3002<\/p>\n\n<p>\u4f46\u5b83\u7684\u7b97\u6cd5\u6f0f\u4e86\u4e00\u4e2a\u5173\u952e\u524d\u63d0\uff1a<strong>\u628a\u300c\u5168\u5c4b 141.79 \u33a1 \u90fd\u8981\u9760\u7a7a\u8c03\u91c7\u6696\u300d\u5f53\u6210\u4e86\u9700\u6c42\u3002<\/strong>\u800c\u8fd9\u5957\u623f\u5b50\u56db\u5c42\u3001\u697c\u68af\u95f4\u8d2f\u901a\u4e0a\u4e0b\uff0c<strong>\u516c\u533a\uff08\u5ba2\u9910\u5385\u3001\u5f71\u5385\uff09\u9760\u7a7a\u8c03\u91c7\u6696\u662f\u65e0\u6548\u7684<\/strong>\u2014\u2014\u70ed\u6c14\u4f1a\u987a\u7740\u697c\u68af\u95f4\u5f80\u4e0a\u62bd\u3001\u4ece\u9876\u5c42\u6563\u6389\uff08\u70df\u56f1\u6548\u5e94\uff09\u3002\u628a\u8fd9\u90e8\u5206\u7b97\u8fdb\u9700\u6c42\uff0c\u624d\u5f97\u51fa\u300c\u5fc5\u987b\u914d\u66f4\u5927\u7684\u673a\u5668\u300d\u3002<\/p>\n\n<blockquote>\n<p><strong>\u6309\u771f\u6b63\u9700\u8981\u91c7\u6696\u7684\u533a\u57df\uff08\u623f\u95f4\uff09\u6765\u6838\uff1a<\/strong><\/p>\n<p>\u771f\u6b63\u9700\u8981\u51ac\u5929\u91c7\u6696\u7684\u623f\u95f4\u9762\u79ef \u2248 <strong>63.4 \u33a1<\/strong>\uff08\u8001\u4eba\u623f \/ \u513f\u7ae5\u623f \/ \u7535\u7ade\u623f \/ \u4e3b\u5367 \/ \u6b21\u5367\uff09<br>\n\u91c7\u6696\u9700\u6c42 63.4 \u00d7 150~200 W\/\u33a1 \u2248 <strong>9.5 ~ 12.7 kW<\/strong>\u3000\uff5c\u3000\u4e3b\u673a <strong>RAS-224 \u5236\u70ed\u80fd\u529b 25.0 kW<\/strong><br>\n\u2192 <strong>25.0 kW &gt; 12.7 kW\uff0c\u91c7\u6696\u80fd\u529b\u662f\u591f\u7684\u3002<\/strong><\/p>\n<\/blockquote>\n\n<p>\u5236\u51b7\u540c\u6837\u591f\uff1a141.79 \u33a1 \u00d7 80~120 W\/\u33a1 \u2248 11.3~17.0 kW \uff1c \u4e3b\u673a 22.4 kW\u3002<\/p>\n\n<h2>\u4e8c\u3001\u8fd9\u5957\u65b9\u6848\u600e\u4e48\u5b9a\u51fa\u6765\u7684\uff1a\u516d\u7ef4\u5ea6\u89e3\u6790\u6cd5<\/h2>\n\n<p>\u8fd9\u5957\u300c\u516d\u7ef4\u5ea6\u89e3\u6790\u6cd5\u300d\uff0c\u662f\u6211\u4eec\u4e8c\u5341\u591a\u5e74\u3001\u4e0a\u5343\u6237\u56de\u8bbf\u6570\u636e\u3001\u56fd\u5bb6\u89c4\u8303\u548c\u4e13\u4e1a\u8d1f\u8377\u8ba1\u7b97\u8f6f\u4ef6\u5171\u540c\u652f\u6491\u7684\u3002\u5b83\u4e0d\u662f\u8bdd\u672f\uff0c\u662f\u4e00\u6761\u6761\u53ef\u4ee5\u6838\u5bf9\u7684\u7406\u7531\u3002<\/p>\n\n<h3>1. \u56fd\u6807\u4f9d\u636e \u2014\u2014 \u79d1\u5b66\u57fa\u77f3<\/h3>\n\n<p>\u56fd\u5bb6\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB 50736-2012\uff1a<strong>\u6210\u90fd\u5730\u533a\u9ad8\u5c42\u4f4f\u5b85\u7684\u5236\u51b7\u8bbe\u8ba1\u8d1f\u8377\u901a\u5e38\u5728 80~120 W\/\u33a1<\/strong>\uff1b\u91c7\u6696\u8bbe\u8ba1\u8d1f\u8377\u53e6\u6309\u51ac\u5b63\u5de5\u51b5\u8ba1\u7b97\u3002<\/p>\n\n<p><strong>\u7528\u5728\u8fd9\u5957\u623f\uff1a<\/strong>\u5236\u51b7 141.79 \u33a1 \u9700 11.3~17.0 kW\uff0c\u4e3b\u673a 22.4 kW \u591f\u3002\u91c7\u6696\u53e6\u7b97\u2014\u2014\u89c1\u7b2c\u4e09\u8282\u3002<\/p>\n\n<h3>2. \u51b7\u6696\u539f\u7406 \u2014\u2014 \u7269\u7406\u5b9a\u5f8b<\/h3>\n\n<p>\u51b7\u7a7a\u6c14\u5bc6\u5ea6\u5927\u3001\u81ea\u7136\u4e0b\u6c89\uff1b\u70ed\u7a7a\u6c14\u5bc6\u5ea6\u5c0f\u3001\u81ea\u7136\u4e0a\u5347\u3002\u5185\u673a\u88c5\u5728\u9876\u4e0a\uff0c<strong>\u590f\u5929\u5236\u51b7\uff0c\u51b7\u6c14\u4ece\u4e0a\u5f80\u4e0b\u9001\uff0c\u6548\u7387\u5f88\u9ad8<\/strong>\uff1b\u51ac\u5929\u5236\u70ed\uff0c\u70ed\u98ce\u5f80\u4e0a\u6d6e\u3001\u5f88\u96be\u538b\u5230\u4eba\u7684\u6d3b\u52a8\u533a\uff0c<strong>\u6240\u4ee5\u7a7a\u8c03\u5236\u70ed\u5929\u751f\u6bd4\u5236\u51b7\u5403\u529b<\/strong>\u3002<\/p>\n\n<p><strong>\u7528\u5728\u8fd9\u5957\u623f\uff1a<\/strong>\u56db\u5c42\u5e26\u697c\u68af\u95f4\uff0c\u7ad6\u5411\u7a7a\u95f4\u8d2f\u901a\uff0c<strong>\u70ed\u91cf\u8dd1\u5f97\u66f4\u5feb<\/strong>\u2014\u2014\u8fd9\u5c31\u662f\u4e3a\u4ec0\u4e48\u516c\u533a\uff08\u5ba2\u9910\u5385\u3001\u5f71\u5385\uff09\u4e0d\u9002\u5408\u6307\u671b\u7a7a\u8c03\u91c7\u6696\uff0c\u800c\u5c01\u95ed\u7684\u623f\u95f4\u5f71\u54cd\u5c0f\u5f97\u591a\u3002<\/p>\n\n<h3>3. \u91c7\u6696\u8303\u56f4 \u2014\u2014 \u9700\u6c42\u786e\u8ba4<\/h3>\n\n<p>\u8bbe\u8ba1\u524d\u5fc5\u987b\u5148\u8ddf\u5ba2\u6237\u786e\u8ba4\u4e00\u53e5\u8bdd\uff1a<strong>\u300c\u60a8\u5bb6\u54ea\u4e9b\u533a\u57df\u51ac\u5929\u662f\u771f\u7684\u8981\u91c7\u6696\u7684\uff1f\u300d<\/strong>\u4e0d\u662f\u300c\u5168\u5c4b\u90fd\u8981\u300d\uff0c\u800c\u662f\u5206\u6e05\uff1a\u54ea\u4e9b\u623f\u95f4\u8981\u6696\uff0c\u54ea\u4e9b\u533a\u57df\u91c7\u6696\u6839\u672c\u65e0\u6548\u3002<\/p>\n\n<p><strong>\u7528\u5728\u8fd9\u5957\u623f\uff1a<\/strong><strong>\u4e0d\u505a\u5730\u6696\uff0c\u623f\u95f4\uff085 \u95f4\uff09\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u516c\u533a\u4e0d\u6307\u671b\u7a7a\u8c03\u91c7\u6696\u3002<\/strong>\u8fd9\u4e2a\u8303\u56f4\u5b9a\u4e86\uff0c\u914d\u7f6e\u624d\u4e0d\u4f1a\u88ab\u865a\u9ad8\u7684\u9700\u6c42\u6491\u5927\u3002<\/p>\n\n<h3>4. \u5206\u4f53\u673a\u7ecf\u9a8c \u2014\u2014 \u7528\u6237\u611f\u77e5<\/h3>\n\n<p>\u56de\u60f3\u5927\u591a\u6570\u4e1a\u4e3b\u4ee5\u524d\u4f4f\u7684\u623f\u5b50\uff1a<strong>\u5ba2\u9910\u5385 30 \u591a\u33a1\uff0c\u4e00\u53f0 2 \u5339\u67dc\u673a\u5c31\u591f\u51c9\u5feb\u3002<\/strong>\u73b0\u5728 48 \u33a1 \u7684\u5ba2\u9910\u5385\u914d\u4e86\u4e24\u53f0\u5185\u673a\uff085.0 + 2.8 kW\uff09\uff0c\u662f\u6309\u300c\u4e24\u53f0\u5206\u5f00\u542f\u3001\u65e5\u5e38\u53ea\u5f00\u4e00\u53f0\u300d\u6765\u8bbe\u8ba1\u7684\u3002<\/p>\n\n<p>\u6240\u4ee5\uff1a\u6a2a\u5411\u6bd4\u4e00\u6bd4\u5c31\u77e5\u9053\uff0c\u8fd9\u5957\u914d\u7f6e\u4e0d\u662f\u5c0f\uff0c\u662f\u5bbd\u88d5\u3002<\/p>\n\n<h3>5. \u8001\u5ba2\u6237\u56de\u8bbf \u2014\u2014 \u6570\u636e\u9a8c\u8bc1<\/h3>\n\n<p>\u6211\u4eec\u5bf9\u6570\u767e\u4f4d\u8001\u5ba2\u6237\u7684\u56de\u8bbf\u6570\u636e\u91cc\u6709\u4e00\u4e2a\u89c4\u5f8b\uff1a<strong>\u51e1\u662f\u5ba2\u9910\u5385\u914d\u4e86\u4e24\u53f0\u5185\u673a\u7684\u7528\u6237\uff0c\u56de\u8bbf\u4e2d\u8d85\u8fc7 90% \u7684\u4eba\u8868\u793a\u590f\u5929\u53ea\u5f00\u4e00\u53f0\u3002<\/strong><\/p>\n\n<p>\u6240\u4ee5\uff1a\u5ba2\u9910\u5385\u7684\u7b2c\u4e8c\u53f0\u5185\u673a\u662f\u300c\u8981\u7528\u7684\u65f6\u5019\u6709\u3001\u4e0d\u7528\u7684\u65f6\u5019\u4e0d\u8d39\u7535\u300d\u7684\u4f59\u91cf\u3002<\/p>\n\n<h3>6. \u7535\u91cf\u63a8\u7b97 \u2014\u2014 \u6210\u672c\u9884\u89c1<\/h3>\n\n<p>\u4e25\u91cd\u8d85\u914d\u7684\u7cfb\u7edf\uff0c\u53ea\u5f00\u4e3b\u5367\u65f6\u5916\u673a\u9891\u7e41\u542f\u505c\uff0c<strong>\u4e00\u4e2a\u590f\u5929\u7684\u7535\u8d39\u4f1a\u6bd4\u79d1\u5b66\u914d\u7f6e\u591a\u51fa 30%~50%<\/strong>\u3002\u7701\u4e0b\u7684\u90a3\u70b9\u521d\u6295\u8d44\uff0c\u4f1a\u5728\u672a\u6765\u51e0\u5e74\u4ee5\u7535\u8d39\u7684\u5f62\u5f0f\u6210\u500d\u8fd8\u56de\u53bb\u3002<\/p>\n\n<p>\u6240\u4ee5\uff1a\u4e0d\u662f\u300c\u8d8a\u5927\u8d8a\u4fdd\u9669\u300d\uff0c\u8d8a\u5927\u5f80\u5f80\u662f\u8d8a\u8d39\u94b1\u3002<\/p>\n\n<h2>\u4e09\u3001\u6309\u8fd9\u5957\u623f\u7684\u771f\u5b9e\u60c5\u51b5\uff0c\u5236\u51b7\u548c\u91c7\u6696\u5206\u5f00\u7b97<\/h2>\n\n<h3>3.1 \u5236\u51b7\uff1a\u591f\uff0c\u800c\u4e14\u6709\u4f59\u91cf<\/h3>\n\n<blockquote>\n<p>\u56fd\u6807\u5236\u51b7\u53e3\u5f84\uff1a141.79 \u33a1 \u00d7 80~120 W\/\u33a1 \uff1d <strong>11.3 ~ 17.0 kW<\/strong><br>\n\u6211\u4eec\u914d\u7684\u4e3b\u673a\uff1a<strong>RAS-224 \u2192 \u5236\u51b7 22.4 kW<\/strong>\u3000\u2192\u3000<strong>22.4 kW &gt; 17.0 kW\uff0c\u5236\u51b7\u80fd\u529b\u6709\u4f59\u91cf<\/strong><\/p>\n<\/blockquote>\n\n<h3>3.2 \u91c7\u6696\uff1a\u5173\u952e\u5728\u300c\u54ea\u4e9b\u533a\u57df\u8981\u91c7\u6696\u300d<\/h3>\n\n<table>\n<thead>\n<tr><th style=\"width:30%\">\u7b97\u6cd5<\/th><th style=\"width:24%\">\u7b97\u51fa\u6765\u7684\u9700\u6c42<\/th><th style=\"width:16%\">\u6211\u4eec\u914d\u7684\uff08\u5236\u70ed\uff09<\/th><th>\u7ed3\u8bba<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td><strong>\u5168\u5c4b\u90fd\u9760\u7a7a\u8c03\u91c7\u6696<\/strong><br>\uff08AI \u53e3\u5f84\uff1a141.79 \u33a1 \u00d7 200 W\/\u33a1\uff09<\/td><td>28.4 kW<\/td><td>25.0 kW<\/td><td>\u53e3\u5f84\u4e0d\u6210\u7acb\uff1a\u516c\u533a\u91c7\u6696\u672c\u6765\u5c31\u662f\u65e0\u6548\u7684<\/td><\/tr>\n<tr><td><strong>\u91c7\u6696 \u00b7 \u623f\u95f4\u6863<\/strong>\uff08\u5b9e\u9645\u9700\u8981\uff09<br>5 \u95f4 \u2248 63.4 \u33a1 \u00d7 100~120 W\/\u33a1\uff08\u5c42\u9ad8\u4f4e\u3001\u5c01\u95ed\uff09<\/td><td>6.3 ~ 7.6 kW<\/td><td>25.0 kW<\/td><td><strong>\u591f<\/strong><\/td><\/tr>\n<tr><td><strong>\u91c7\u6696 \u00b7 \u6309\u504f\u9ad8\u4fdd\u5b88\u503c<\/strong>\uff08\u6211\u4eec\u6838\u7b97\u7528\uff09<br>63.4 \u33a1 \u00d7 150~200 W\/\u33a1\uff08\u6309\u516c\u533a\u8017\u70ed\u5927\u6237\u6863\uff09<\/td><td>9.5 ~ 12.7 kW<\/td><td>25.0 kW<\/td><td><strong>\u53d6\u9ad8\u503c\u4e5f\u7b97\u5f97\u8fc7\u6765<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p><strong>\u5173\u4e8e\u91c7\u6696\u8d1f\u8377\u7684\u4e24\u4e2a\u6863\u4f4d\uff08\u8bf4\u660e\u6211\u4eec\u4e3a\u4ec0\u4e48\u300c\u53d6\u504f\u9ad8\u4fdd\u5b88\u503c\u6838\u7b97\u300d\uff09\uff1a<\/strong><\/p>\n\n<ul>\n<li><strong>\u516c\u533a\u6863\uff08\u6311\u7a7a \/ \u697c\u68af\u95f4\u516c\u533a\uff09\uff1a150~200 W\/\u33a1<\/strong>\u2014\u2014\u6311\u7a7a\u3001\u5927\u73bb\u7483\u3001\u697c\u68af\u95f4\u8d2f\u901a\uff0c\u70ed\u91cf\u6563\u5931\u5feb\uff0c\u5c5e\u4e8e\u8017\u70ed\u5927\u6237\uff1b<\/li>\n<li><strong>\u623f\u95f4\u6863\uff08\u5c42\u9ad8\u4f4e\u3001\u7a7a\u95f4\u5c01\u95ed\u7684\u5367\u5ba4\uff09\uff1a100~120 W\/\u33a1<\/strong>\u2014\u2014\u6210\u90fd\u666e\u901a\u4f4f\u5b85\u7684\u91c7\u6696\u6c34\u5e73\uff0c\u5c01\u95ed\u623f\u95f4\u5bf9\u6d41\u635f\u5931\u5c0f\u3002<\/li>\n<\/ul>\n\n<p>\u6211\u4eec\u8fd9\u4e00\u8282\u6838\u7b97\u65f6\uff0c<strong>\u5bf9 5 \u4e2a\u623f\u95f4\u4e5f\u7edf\u4e00\u6309 150~200 \u7684\u516c\u533a\u9ad8\u503c\u6765\u7b97<\/strong>\uff089.5~12.7 kW\uff09\uff0c\u53d6\u7684\u662f\u4e0d\u5229\u60c5\u51b5\u2014\u2014\u53d6\u9ad8\u503c\u90fd\u591f\uff0c\u7ed3\u8bba\u624d\u7ad9\u5f97\u4f4f\u3002<\/p>\n\n<p>\u9700\u8981\u91c7\u6696\u7684\u623f\u95f4\uff1a\u8001\u4eba\u623f 12.49 + \u513f\u7ae5\u623f 15.5 + \u7535\u7ade\u623f 6 + \u4e3b\u5367\uff0b\u8863\u5e3d\u95f4 18.4 + \u6b21\u5367 11 \uff1d <strong>63.39 \u33a1<\/strong>\u3002<\/p>\n\n<blockquote>\n<p><strong>\u3010\u8bda\u5b9e\u544a\u77e5\u3011<\/strong>\u8fd9\u5957\u623f\u4e0d\u505a\u5730\u6696\uff0c<strong>\u5ba2\u9910\u5385\u548c\u5f71\u5385\u8fd9\u4e24\u5904\u516c\u533a\uff0c\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\u7684\u6548\u679c\u662f\u6709\u9650\u7684<\/strong>\u2014\u2014\u4e0d\u662f\u914d\u7f6e\u4e0d\u591f\uff0c\u662f\u56db\u5c42\u5e26\u697c\u68af\u95f4\u7684\u623f\u5b50\uff0c\u70ed\u6c14\u4f1a\u4ece\u697c\u68af\u95f4\u8dd1\u6389\uff0c\u8fd9\u662f\u623f\u5b50\u7684\u5ba2\u89c2\u6761\u4ef6\u3002\u6240\u4ee5\u6211\u4eec\u7684\u505a\u6cd5\u662f\uff1a<strong>\u628a\u5236\u70ed\u80fd\u529b\u7528\u5728\u771f\u6b63\u7559\u5f97\u4f4f\u70ed\u7684\u623f\u95f4\u91cc\uff0c\u4e0d\u5728\u7559\u4e0d\u4f4f\u70ed\u7684\u5730\u65b9\u5806\u94b1\u3002<\/strong>\u5982\u679c\u4ee5\u540e\u5e0c\u671b\u5ba2\u9910\u5385\u51ac\u5929\u4e5f\u8212\u670d\uff0c\u6700\u6709\u6548\u7684\u529e\u6cd5\u662f\u7ed9\u516c\u533a\u5355\u72ec\u505a\u5c40\u90e8\u91c7\u6696\uff08\u6bd4\u5982\u5c40\u5730\u6696\u6216\u72ec\u7acb\u53d6\u6696\u8bbe\u5907\uff09\uff0c\u8fd9\u6bd4\u5728\u7a7a\u8c03\u4e0a\u52a0\u5927\u914d\u7f6e\u5212\u7b97\u5f97\u591a\u3002<\/p>\n<\/blockquote>\n\n<h2>\u56db\u3001\u9010\u623f\u95f4\u6838\u4e00\u904d\uff08\u6bcf\u4e2a\u623f\u95f4\u90fd\u4e0d\u662f\u62cd\u8111\u888b\uff09<\/h2>\n\n<p>\u5185\u673a\u662f\u6309\u6bcf\u4e2a\u623f\u95f4\u5355\u72ec\u9009\u7684\uff0c\u4e0d\u662f\u62ff\u603b\u9762\u79ef\u9664\u4e00\u9664\u3002\u4ece\u4e0b\u8868\u53ef\u4ee5\u770b\u51fa\uff0c<strong>\u6bcf\u4e2a\u623f\u95f4\u914d\u7684\u5355\u4f4d\u51b7\u91cf\u90fd\u8fdc\u9ad8\u4e8e\u56fd\u6807\u5236\u51b7\u57fa\u51c6 80~120 W\/\u33a1<\/strong>\u2014\u2014\u8db3\uff0c\u4e0d\u7f3a\u3002<\/p>\n\n<table>\n<thead>\n<tr><th style=\"width:13%\">\u697c\u5c42<\/th><th style=\"width:16%\">\u7a7a\u95f4<\/th><th style=\"width:11%\">\u9762\u79ef \u33a1<\/th><th style=\"width:14%\">\u914d\u7684\u5bb9\u91cf<\/th><th style=\"width:15%\">\u6298\u7b97\u5355\u4f4d\u51b7\u91cf<\/th><th>\u51ac\u5b63\u91c7\u6696<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5f71\u5385<\/td><td>30.4<\/td><td>5.0 kW<\/td><td>164 W\/\u33a1<\/td><td>\u516c\u533a \u00b7 \u7a7a\u8c03\u91c7\u6696\u6548\u679c\u6709\u9650<\/td><\/tr>\n<tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>48<\/td><td>5.0 + 2.8 kW<\/td><td>162 W\/\u33a1<\/td><td>\u516c\u533a \u00b7 \u7a7a\u8c03\u91c7\u6696\u6548\u679c\u6709\u9650<\/td><\/tr>\n<tr><td>\u4e8c\u697c<\/td><td>\u8001\u4eba\u623f<\/td><td>12.49<\/td><td>2.8 kW<\/td><td>224 W\/\u33a1<\/td><td><strong>\u53ef\u91c7\u6696<\/strong><\/td><\/tr>\n<tr><td>\u4e8c\u697c<\/td><td>\u513f\u7ae5\u623f<\/td><td>15.5<\/td><td>3.2 kW<\/td><td>206 W\/\u33a1<\/td><td><strong>\u53ef\u91c7\u6696<\/strong><\/td><\/tr>\n<tr><td>\u4e8c\u697c<\/td><td>\u7535\u7ade\u623f<\/td><td>6<\/td><td>1.8 kW<\/td><td>300 W\/\u33a1<\/td><td><strong>\u53ef\u91c7\u6696<\/strong><\/td><\/tr>\n<tr><td>\u4e09\u697c<\/td><td>\u4e3b\u5367\uff0b\u8863\u5e3d\u95f4<\/td><td>18.4<\/td><td>4.0 kW<\/td><td>217 W\/\u33a1<\/td><td><strong>\u53ef\u91c7\u6696<\/strong><\/td><\/tr>\n<tr><td>\u4e09\u697c<\/td><td>\u6b21\u5367<\/td><td>11<\/td><td>2.5 kW<\/td><td>227 W\/\u33a1<\/td><td><strong>\u53ef\u91c7\u6696<\/strong><\/td><\/tr>\n<tr><td>\u2014<\/td><td><strong>8 \u53f0\u5185\u673a<\/strong><\/td><td><strong>141.79<\/strong><\/td><td><strong>27.1 kW<\/strong><\/td><td>\u2014<\/td><td>\u9700\u91c7\u6696\u623f\u95f4 63.4 \u33a1<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<blockquote>\n<p><strong>\u4e00\u53e5\u8bdd\uff1a<\/strong>\u5185\u673a\u914d\u5230 162~300 W\/\u33a1\uff0c\u5236\u51b7\u7528\u4e0d\u5b8c\uff1b\u91c7\u6696\u53ea\u538b\u5728 5 \u4e2a\u623f\u95f4\u4e0a\uff0c\u4e3b\u673a 25 kW \u5236\u70ed\u5bf9\u7740 12.7 kW \u7684\u9700\u6c42\uff0c<strong>\u4f59\u91cf\u8fd8\u5f88\u5927<\/strong>\u3002\u8fd9\u4e0d\u662f\u300c\u914d\u5c0f\u4e86\u300d\u3002<\/p>\n<\/blockquote>\n\n<h2>\u4e94\u3001\u4e3a\u4ec0\u4e48\u300c\u516c\u533a\u518d\u52a0\u4e00\u53f0\u3001\u5236\u70ed\u914d\u5927\u70b9\u300d\u662f\u767d\u82b1\u94b1<\/h2>\n\n<h3>5.1 \u70df\u56f1\u6548\u5e94\uff1a\u591a\u697c\u5c42\u91cc\uff0c\u70ed\u6c14\u662f\u5f80\u4e0a\u8dd1\u6389\u7684<\/h3>\n\n<p>\u8fd9\u5957\u623f\u5b50\u56db\u5c42\uff08\u542b\u8d1f\u4e00\u697c\uff09\uff0c\u697c\u68af\u95f4\u8d2f\u901a\u4e0a\u4e0b\u3002\u70ed\u7a7a\u6c14\u5bc6\u5ea6\u5c0f\u3001\u81ea\u7136\u5f80\u4e0a\u8d70\uff0c<strong>\u70ed\u6c14\u4f1a\u987a\u7740\u697c\u68af\u95f4\u8fd9\u7c7b\u7ad6\u5411\u7a7a\u95f4\u5f80\u4e0a\u62bd\uff0c\u4ece\u9876\u5c42\u548c\u7f1d\u9699\u6563\u51fa\u53bb<\/strong>\u2014\u2014\u8fd9\u5c31\u662f\u70df\u56f1\u6548\u5e94\u3002<\/p>\n\n<ul>\n<li>\u7a7a\u8c03\u5236\u70ed\u662f<strong>\u4ece\u9876\u4e0a\u5f80\u4e0b\u5439\u70ed\u98ce<\/strong>\uff0c\u800c\u70ed\u98ce\u672c\u6765\u5c31\u5f80\u4e0a\u6d6e\uff0c\u5f88\u96be\u538b\u5230\u4eba\u5750\u7740\u7684\u6d3b\u52a8\u533a\uff1b<\/li>\n<li>\u697c\u5c42\u8d8a\u591a\u3001\u516c\u533a\u8d8a\u655e\u5f00\uff08\u6311\u7a7a\u3001\u697c\u68af\u53e3\uff09\uff0c<strong>\u70ed\u91cf\u8dd1\u5f97\u8d8a\u5feb<\/strong>\uff1b<\/li>\n<li>\u7ed3\u679c\u5c31\u662f\uff1a\u516c\u533a\u5c31\u7b97\u628a\u5236\u70ed\u80fd\u529b\u52a0\u5927\uff0c<strong>\u591a\u51fa\u6765\u7684\u70ed\u91cf\u5927\u90e8\u5206\u76f4\u63a5\u635f\u5931\u6389\u4e86<\/strong>\u2014\u2014\u4eba\u611f\u89c9\u4e0d\u5230\u6696\u548c\uff0c\u7535\u8d39\u5374\u5b9e\u6253\u5b9e\u4e0a\u53bb\u4e86\u3002<\/li>\n<\/ul>\n\n<blockquote>\n<p><strong>\u6240\u4ee5\u5728\u516c\u533a\u5806\u5236\u70ed\u914d\u7f6e\uff0c\u7b49\u4e8e\u82b1\u94b1\u4e70\u70ed\u91cf\u3001\u518d\u8ba9\u5b83\u4ece\u697c\u68af\u95f4\u8dd1\u6389\u3002<\/strong>\u8fd9\u90e8\u5206\u94b1\u548c\u4ee5\u540e\u6bcf\u5e74\u7684\u80fd\u8017\uff0c\u672c\u6765\u5c31\u4e0d\u8be5\u82b1\u2014\u2014\u6211\u4eec\u662f\u66ff\u4e1a\u4e3b\u7701\u4e0b\u6765\uff0c\u4e0d\u662f\u4e0d\u7ed9\u914d\u3002<a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66<\/a>\u91cc\u5bf9\u8fd9\u4e00\u6761\u6709\u5b8c\u6574\u63a8\u6f14\u3002<\/p>\n<\/blockquote>\n\n<h3>5.2 \u4e3a\u4ec0\u4e48\u590f\u5929\u914d\u5927\u4e86\u53cd\u800c\u66f4\u7cdf\uff1a\u300c\u5927\u9a6c\u62c9\u5c0f\u8f66\u300d<\/h3>\n\n<p>\u5982\u679c\u4e3a\u4e86\u300c\u51ac\u5929\u4fdd\u9669\u300d\u628a\u4e3b\u673a\u548c\u5185\u673a\u914d\u5f97\u8fdc\u8d85\u5b9e\u9645\u9700\u8981\uff0c\u590f\u5929\u5c31\u4f1a\u51fa\u95ee\u9898\uff1a<\/p>\n\n<table>\n<thead>\n<tr><th style=\"width:30%\">\u53d1\u751f\u4ec0\u4e48<\/th><th>\u4e3a\u4ec0\u4e48\u4f1a\u8fd9\u6837<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td><strong>\u623f\u95f4\u5230\u6e29\u592a\u5feb<\/strong><\/td><td>\u914d\u7f6e\u8fdc\u8d85\u8d1f\u8377\uff0c\u5f00\u673a\u6ca1\u591a\u4e45\u5ba4\u6e29\u5c31\u63a5\u8fd1\u8bbe\u5b9a\u503c\uff0c\u7cfb\u7edf\u53ea\u9700\u8981\u5f88\u5c11\u7684\u51b7\u91cf<\/td><\/tr>\n<tr><td><strong>\u7535\u5b50\u81a8\u80c0\u9600\u5f00\u5ea6\u6781\u5c0f<\/strong><\/td><td>\u51b7\u91cf\u9700\u6c42\u4f4e\uff0c\u81a8\u80c0\u9600\u628a\u6d41\u91cf\u6536\u5230\u5f88\u5c0f\uff1b\u4f46\u538b\u7f29\u673a\u8f6c\u901f\u4ecd\u504f\u9ad8\uff0c<strong>\u51b7\u5a92\u5728\u6781\u5c0f\u5f00\u5ea6\u4e0b\u6d41\u901f\u5f88\u9ad8\uff0c\u5f62\u6210\u7c7b\u4f3c\u300c\u6c34\u9524\u300d\u7684\u51b2\u51fb\u4e0e\u6d41\u52a8\u566a\u97f3<\/strong><\/td><\/tr>\n<tr><td><strong>\u590f\u5929\u6548\u679c\u5dee\u3001\u566a\u97f3\u9ad8<\/strong><\/td><td>\u51b7\u5a92\u5206\u914d\u4e0d\u7a33\u5b9a\uff0c\u623f\u95f4\u5ffd\u51b7\u5ffd\u70ed\uff1b\u5c0f\u5f00\u5ea6\u4e0b\u7684\u6d41\u52a8\u566a\u97f3\u5728\u5b89\u9759\u65f6\u5c24\u5176\u660e\u663e<\/td><\/tr>\n<tr><td><strong>\u538b\u7f29\u673a\u9891\u7e41\u542f\u505c<\/strong><\/td><td>\u5927\u673a\u5668\u5e26\u5c0f\u8d1f\u8377\uff0c\u53cd\u590d\u542f\u505c\u2014\u2014<strong>\u65e2\u8d39\u7535\uff0c\u53c8\u52a0\u901f\u90e8\u4ef6\u635f\u8017\uff0c\u6545\u969c\u7387\u8ddf\u7740\u4e0a\u5347<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<blockquote>\n<p><strong>\u4e00\u53e5\u8bdd\uff1a\u4e3a\u51ac\u5929\u865a\u9ad8\u7684\u9700\u6c42\u628a\u673a\u5668\u914d\u5927\uff0c\u590f\u5929\u4f1a\u53d8\u6210\u566a\u97f3\u3001\u5ffd\u51b7\u5ffd\u70ed\u3001\u9ad8\u7535\u8d39\u548c\u66f4\u9ad8\u7684\u6545\u969c\u7387\u8fd8\u56de\u6765\u3002<\/strong>\u914d\u7f6e\u4e0d\u662f\u8d8a\u5927\u8d8a\u4fdd\u9669\uff0c\u8d8a\u5927\u5f80\u5f80\u8d8a\u96be\u7528\u3002<\/p>\n<\/blockquote>\n\n<h3>5.3 \u6211\u4eec\u7684\u914d\u7f6e\u903b\u8f91<\/h3>\n\n<ul>\n<li><strong>\u5236\u51b7\u6309\u5b9e\u9700\u914d\u8db3<\/strong>\uff1a\u6309\u56fd\u6807\u8d1f\u8377\u9010\u95f4\u9009\u578b\uff0c\u7559\u51fa\u4f59\u91cf\uff0c\u590f\u5929\u5f00\u7740\u51c9\u5feb\u3001\u5b89\u9759\u3001\u7701\u7535\uff1b<\/li>\n<li><strong>\u91c7\u6696\u53ea\u538b\u5728\u771f\u6b63\u7559\u5f97\u4f4f\u70ed\u7684\u623f\u95f4<\/strong>\uff1a5 \u95f4\u623f\u6309\u91c7\u6696\u5de5\u51b5\u6838\u8fc7\uff0c\u4e3b\u673a 25 kW \u5236\u70ed\u4f59\u91cf\u5145\u8db3\uff1b<\/li>\n<li><strong>\u516c\u533a\u4e0d\u5806\u5236\u70ed<\/strong>\uff1a\u70df\u56f1\u6548\u5e94\u51b3\u5b9a\u90a3\u91cc\u7684\u94b1\u662f\u767d\u82b1\uff0c\u6211\u4eec\u628a\u94b1\u7701\u4e0b\u6765\uff0c\u800c\u4e0d\u662f\u8ba9\u4e1a\u4e3b\u767d\u6295\uff1b<\/li>\n<li><strong>\u516c\u533a\u91c7\u6696\u7684\u5c40\u9650\u5982\u5b9e\u8bf4<\/strong>\uff1a\u60f3\u5f7b\u5e95\u89e3\u51b3\uff0c\u5e94\u8be5\u7ed9\u516c\u533a\u5355\u72ec\u505a\u5c40\u90e8\u91c7\u6696\uff0c\u800c\u4e0d\u662f\u52a0\u7a7a\u8c03\u914d\u7f6e\u3002<\/li>\n<\/ul>\n\n<h3>5.4 \u90a3\u516c\u533a\u51ac\u5929\u8981\u6696\uff0c\u5230\u5e95\u8be5\u600e\u4e48\u505a\u624d\u4e0d\u6d6a\u8d39\u94b1<\/h3>\n\n<p>\u4e00\u53e5\u8bdd\uff1a<strong>\u4e0d\u8981\u5728\u7a7a\u8c03\u4e0a\u52a0\u914d\u7f6e\uff0c\u8981\u5728\u516c\u533a\u5355\u72ec\u505a\u91c7\u6696\u8bbe\u5907\u3002<\/strong>\u5982\u679c\u505a\u6696\u6c14\u7247\uff0c\u9009\u578b\u4e0a\u6709\u4e00\u4e2a\u5173\u952e\u8bb2\u7a76\u2014\u2014\u540c\u4e00\u4ef6\u4e8b\uff0c\u9009\u9519\u4e86\u578b\u53f7\uff0c\u94b1\u7167\u6837\u767d\u82b1\u3002<\/p>\n\n<table>\n<thead>\n<tr><th style=\"width:20%\">\u8bbe\u5907\u7c7b\u578b<\/th><th style=\"width:32%\">\u4f20\u70ed\u65b9\u5f0f<\/th><th style=\"width:32%\">\u7528\u5728\u6311\u7a7a\u516c\u533a\u4f1a\u600e\u6837<\/th><th>\u7ed3\u8bba<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td><strong>\u94a2\u5236\u677f\u5f0f\u6563\u70ed\u5668<\/strong><\/td><td>\u4ee5\u5bf9\u6d41\u4e3a\u4e3b\uff08\u7ea6 70% \u5bf9\u6d41 + 30% \u8f90\u5c04\uff09\uff1a\u5148\u628a\u7a7a\u6c14\u52a0\u70ed\uff0c\u9760\u70ed\u7a7a\u6c14\u4e0a\u5347\u5faa\u73af<\/td><td>\u7a7a\u6c14\u4e00\u88ab\u52a0\u70ed\u5c31\u5f80\u4e0a\u5347\uff0c\u987a\u7740\u697c\u68af\u95f4\u8dd1\u6389\u2014\u2014<strong>\u70e7\u51fa\u6765\u7684\u70ed\u91cf\u5927\u90e8\u5206\u88ab\u642c\u5230\u4e86\u4eba\u591f\u4e0d\u7740\u7684\u5730\u65b9<\/strong><\/td><td>\u4e0d\u9002\u5408\u516c\u533a<\/td><\/tr>\n<tr><td><strong>\u67f1\u5f0f\u8f90\u5c04\u6563\u70ed\u5668<\/strong><\/td><td>\u8f90\u5c04\u5360\u6bd4\u660e\u663e\u9ad8\u4e8e\u677f\u5f0f\uff1a\u76f4\u63a5\u4ee5\u8f90\u5c04\u52a0\u70ed\u4eba\u4f53\u548c\u7269\u4f53\u8868\u9762\uff0c<strong>\u4e0d\u4f9d\u8d56\u7a7a\u6c14\u642c\u8fd0\u70ed\u91cf<\/strong><\/td><td>\u70ed\u91cf\u76f4\u63a5\u7ed9\u5230\u4eba\u548c\u5bb6\u5177\uff0c<strong>\u4e0d\u8ffd\u7740\u7a7a\u6c14\u5f80\u4e0a\u8dd1<\/strong>\uff0c\u5728\u6311\u7a7a\u3001\u6709\u7ad6\u5411\u5f00\u53e3\u7684\u7a7a\u95f4\u91cc\u635f\u5931\u5c0f\u5f97\u591a<\/td><td><strong>\u9002\u5408\u516c\u533a<\/strong><\/td><\/tr>\n<tr><td><strong>\u5367\u5ba4 \/ \u5c01\u95ed\u623f\u95f4<\/strong><\/td><td>\u5c42\u9ad8\u4f4e\u3001\u7a7a\u95f4\u5c01\u95ed\uff0c\u5bf9\u6d41\u7684\u635f\u5931\u672c\u6765\u5c31\u5c0f<\/td><td>\u2014<\/td><td><strong>\u677f\u5f0f\u5373\u53ef\uff0c\u7701\u5730\u65b9<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p><strong>\u539f\u7406\u4f9d\u636e\uff1a<\/strong>\u2460 \u94a2\u5236\u677f\u5f0f\u6563\u70ed\u5668\u7684\u4f20\u70ed\u7ea6\u4e03\u6210\u9760\u5bf9\u6d41\uff08\u52a0\u70ed\u7a7a\u6c14\uff09\uff0c\u5728\u6311\u7a7a\u7a7a\u95f4\u91cc\u8fd9\u90e8\u5206\u70ed\u91cf\u968f\u7a7a\u6c14\u4e0a\u6d6e\u6d41\u5931\uff1b\u2461 \u8f90\u5c04\u4f9b\u6696\u5728<strong>\u9ad8\u5927\u3001\u6311\u7a7a\u7a7a\u95f4<\/strong>\u6709\u660e\u786e\u4f18\u52bf\u2014\u2014\u4e13\u4e1a\u6559\u6750\u8bb2\u7a3f\u6307\u51fa\uff0c\u8f90\u5c04\u4f9b\u6696\u65f6\u7ad6\u5411\u6e29\u5ea6\u68af\u5ea6\u6bd4\u5bf9\u6d41\u4f9b\u6696\u5c0f\uff0c\u70ed\u91cf\u76f4\u63a5\u4f5c\u7528\u5728\u4eba\u8eab\u4e0a\uff0c\u4e0d\u9760\u628a\u7a7a\u6c14\u52a0\u70ed\u3002\u6696\u6c14\u7247\u8fd9\u4e00\u5757\u7684\u5b8c\u6574\u4f9d\u636e\uff0c\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=12447\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/a>\u3002<\/p>\n\n<blockquote>\n<p><strong>\u6240\u4ee5\u8fd9\u5957\u623f\u4ee5\u540e\u5982\u679c\u8981\u7ed9\u516c\u533a\u8865\u91c7\u6696\uff1a<\/strong>\u6311\u7a7a\u3001\u5e26\u697c\u68af\u95f4\u7684\u5ba2\u9910\u5385\u548c\u5f71\u5385\uff0c<strong>\u7528\u67f1\u5f0f\u8f90\u5c04\u6563\u70ed\u5668<\/strong>\uff1b\u5c42\u9ad8\u4f4e\u3001\u5c01\u95ed\u7684\u5367\u5ba4\uff0c<strong>\u7528\u677f\u5f0f\u5c31\u591f<\/strong>\u3002\u8fd9\u662f\u300c\u9009\u5bf9\u578b\u53f7\u300d\uff0c\u4e0d\u662f\u300c\u52a0\u5927\u529f\u7387\u300d\u2014\u2014\u540c\u6837\u82b1\u94b1\uff0c\u6548\u679c\u5dee\u5f88\u8fdc\u3002<\/p>\n<\/blockquote>\n\n<h2>\u516d\u3001\u6211\u4eec\u4e0d\u662f\u4f30\u7684\uff0c\u662f\u7b97\u51fa\u6765\u7684<\/h2>\n\n<p>\u4e0a\u9762\u56fd\u6807\u90a3\u4e00\u680f\u7684 80~120 W\/\u33a1 \u662f\u89c4\u8303\u503c\u3002\u843d\u5230\u5177\u4f53\u623f\u5b50\uff0c\u6211\u4eec\u7528\u4e13\u4e1a\u8f6f\u4ef6\uff08\u9e3f\u4e1a\u8d1f\u8377\u8ba1\u7b97\uff09\u505a\u9010\u65f6\u52a8\u6001\u8d1f\u8377\u8ba1\u7b97\uff0c\u5f62\u6210\u53ef\u4ee5\u5f53\u573a\u51fa\u793a\u7684\u8bbe\u8ba1\u4f9d\u636e\u3002\u53c2\u8003\u6211\u4eec\u5176\u4ed6\u9879\u76ee\u7684\u8ba1\u7b97\u4e66\uff1a<\/p>\n\n<table>\n<thead>\n<tr><th>\u8ba1\u7b97\u4e66<\/th><th>\u5173\u952e\u7ed3\u679c<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>\u300a\u5168\u5e74\u8d1f\u8377\u8ba1\u7b97\u300b<br>\uff08\u6210\u90fd 178 \u33a1 \u8282\u80fd\u5efa\u7b51\uff09<\/td><td>7 \u6708\u6708\u5e73\u5747\u51b7\u6307\u6807 <strong>46 W\/\u33a1<\/strong>\uff1b12 \u6708\u6708\u5e73\u5747\u70ed\u6307\u6807 <strong>45 W\/\u33a1<\/strong><\/td><\/tr>\n<tr><td>\u540c\u4e0a \u00b7 \u8bbe\u8ba1\u65e5<\/td><td>\u6700\u70ed\u65e5\uff087\/27\uff09\u65e5\u5747 55 W\/\u33a1 \u2192 \u8bbe\u8ba1\u51b7\u6307\u6807 <strong>&gt;88 W\/\u33a1<\/strong>\uff1b\u6700\u51b7\u65e5\uff081\/25\uff0956 W\/\u33a1 \u2192 \u8bbe\u8ba1\u70ed\u6307\u6807 <strong>&gt;67 W\/\u33a1<\/strong><\/td><\/tr>\n<tr><td>\u300a\u6d32\u9645\u94f6\u6d77\u6e7e\u5ba2\u9910\u5385\u8d1f\u8377\u8ba1\u7b97\u4e66\u300b<\/td><td>\u5ba2\u5385\u590f\u5cf0 <strong>124 W\/\u33a1<\/strong>\uff08\u542b\u65b0\u98ce\uff09\u3001\u51ac\u91c7\u6696 61.4 W\/\u33a1\uff1b\u9910\u5385\u590f\u5cf0 117.1 W\/\u33a1\u3001\u51ac 53.6 W\/\u33a1<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p>\u7528\u6cd5\uff1a<strong>\u914d\u578b\u6309\u8bbe\u8ba1\u65e5\u6700\u9ad8\u8d1f\u8377\uff0c\u7b97\u8d39\u7528\u6309\u6708\u5e73\u5747\u4f7f\u7528\u8d1f\u8377\u3002<\/strong>\u51ed\u8ba1\u7b97\u4e66\uff0c\u6211\u4eec\u80fd\u5f53\u573a\u56de\u7b54\u300c\u8fd9\u5957\u623f\u4e3a\u4ec0\u4e48\u914d\u8fd9\u4e48\u5927\u3001\u8fd9\u4e48\u5c0f\u300d\uff0c\u4e5f\u80fd\u53cd\u7b97\u300c\u4e00\u5e74\u7535\u8d39\u5927\u6982\u591a\u5c11\u300d\u2014\u2014\u8fd9\u6b63\u662f\u5957\u6a21\u677f\u62a5\u65b9\u6848\u62ff\u4e0d\u51fa\u6765\u7684\u4e1c\u897f\u3002<\/p>\n\n<p>\u8fd9\u5957\u9ec4\u9f99\u6eaa\u623f\u5b50\u7684\u300a\u9010\u65f6\u8d1f\u8377\u8ba1\u7b97\u4e66\u300b\uff08\u542b\u5236\u51b7\u4e0e\u91c7\u6696\u4e24\u4fa7\uff09\uff0c\u6211\u4eec\u5355\u72ec\u51fa\u4e00\u4efd\uff0c\u968f\u65b9\u6848\u4e00\u8d77\u7ed9\u4e1a\u4e3b\u5b58\u6863\u3002<\/p>\n\n<h2>\u4e03\u3001\u6237\u578b\u4e0e\u5185\u673a\u914d\u7f6e<\/h2>\n\n<p>\u4e24\u5957\u65b9\u6848\u7684\u5185\u673a\u5bb9\u91cf\u4e00\u81f4\uff0c<strong>\u5171 8 \u53f0 \u00b7 \u5408\u8ba1 141.79 \u33a1<\/strong>\u3002<\/p>\n\n<table>\n<thead>\n<tr><th>\u697c\u5c42<\/th><th>\u7a7a\u95f4<\/th><th>\u9762\u79ef \u33a1<\/th><th>\u5185\u673a\u5bb9\u91cf<\/th><th>\u8bf4\u660e<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>\u8d1f\u4e00\u697c<\/td><td>\u5f71\u5385<\/td><td>30.4<\/td><td>50 \u578b<\/td><td>\u5355\u53f0<\/td><\/tr>\n<tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>48<\/td><td>50 \u578b + 28 \u578b<\/td><td>\u4e24\u53f0\u8986\u76d6<\/td><\/tr>\n<tr><td>\u4e8c\u697c<\/td><td>\u8001\u4eba\u623f<\/td><td>12.49<\/td><td>28 \u578b<\/td><td>\u5355\u53f0<\/td><\/tr>\n<tr><td>\u4e8c\u697c<\/td><td>\u513f\u7ae5\u623f<\/td><td>15.5<\/td><td>32 \u578b<\/td><td>\u5355\u53f0<\/td><\/tr>\n<tr><td>\u4e8c\u697c<\/td><td>\u7535\u7ade\u623f<\/td><td>6<\/td><td>18 \u578b<\/td><td>\u5355\u53f0\uff08\u5c0f\u7a7a\u95f4\uff09<\/td><\/tr>\n<tr><td>\u4e09\u697c<\/td><td>\u4e3b\u5367\uff0b\u8863\u5e3d\u95f4<\/td><td>18.4<\/td><td>40 \u578b<\/td><td>\u5355\u53f0<\/td><\/tr>\n<tr><td>\u4e09\u697c<\/td><td>\u6b21\u5367<\/td><td>11<\/td><td>25 \u578b<\/td><td>\u5355\u53f0<\/td><\/tr>\n<tr><td>\u5171\u8ba1<\/td><td>\u2014<\/td><td><strong>141.79<\/strong><\/td><td><strong>8 \u53f0<\/strong><\/td><td>\u2014<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h2>\u516b\u3001\u4e24\u5957\u65b9\u6848\u5bf9\u7167\uff08\u914d\u7f6e\u90e8\u5206\uff09<\/h2>\n\n<p>\u4e24\u5957\u65b9\u6848\u7684\u5dee\u522b\u4e3b\u8981\u5728<strong>\u4e3b\u673a<\/strong>\uff1a\u65b9\u6848\u4e00\u662f\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff08\u540c\u5f00\u5c11\u65f6\u66f4\u7701\u7535\uff09\uff0c\u65b9\u6848\u4e8c\u662f\u8865\u6c14\u589e\u7113\u00b7\u6da1\u65cb\u538b\u7f29\u673a\uff08\u540c\u5f00\u591a\u65f6\u66f4\u7701\u7535\uff09\u3002<strong>\u5185\u673a\u4e24\u5957\u90fd\u662f\u4e24\u7ba1\u5236\uff0c\u914d\u7f6e\u5b8c\u5168\u76f8\u540c<\/strong>\uff0c\u6240\u4ee5\u4e0b\u9762\u6bcf\u4e00\u884c\u5de6\u53f3\u90fd\u4e00\u4e00\u5bf9\u5e94\u3002<\/p>\n\n<table>\n<colgroup><col style=\"width:104px;\"><col><col><\/colgroup>\n<thead>\n<tr>\n<th><\/th>\n<th>\u65b9\u6848\u4e00 \u00b7 \u8212\u4eab\u7cfb\u5217<br>\u8212\u4eab\u53cc\u98ce\u6247 224 \u00b7 \u62d6 8 \u53f0\u5185\u673a<\/th>\n<th>\u65b9\u6848\u4e8c \u00b7 \u5c0a\u777f\u5168\u6548\u7cfb\u5217<br>\u5c0a\u777f\u5168\u6548\u53cc\u98ce\u6247 224 \u00b7 \u62d6 8 \u53f0\u5185\u673a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td colspan=\"3\"><strong>\u57fa\u672c\u5bf9\u6bd4<\/strong><\/td><\/tr>\n<tr><td>\u9002\u7528\u697c\u5c42<\/td><td>\u4e00\u3001\u4e8c\u3001\u4e09\u697c\u6d3b\u52a8\u533a<\/td><td>\u4e8c\u3001\u4e09\u697c\u6d3b\u52a8\u533a<\/td><\/tr>\n<tr><td>\u538b\u7f29\u673a<\/td><td>\u53d8\u9891\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<br><strong>\uff08\u9002\u5408\u540c\u5f00\u5c11\u7684\u65f6\u5019\uff09<\/strong><\/td><td>\u53d8\u9891\u8865\u6c14\u589e\u7113 \u00b7 \u6da1\u65cb\u538b\u7f29\u673a<br><strong>\uff08\u9002\u5408\u540c\u5f00\u591a\u7684\u65f6\u5019\uff09<\/strong><\/td><\/tr>\n<tr><td>\u4f18\u70b9<\/td><td>\u4e3b\u673a\u529f\u7387\u6bd4\u8f83\u5408\u9002\uff1b<strong>\u5185\u673a\u540c\u5f00\u5c11\u7684\u65f6\u5019\u66f4\u7701\u7535<\/strong><\/td><td>\u4e3b\u673a\u529f\u7387\u6bd4\u8f83\u5408\u9002\uff1b<strong>\u5185\u673a\u540c\u5f00\u591a\u7684\u65f6\u5019\u66f4\u7701\u7535<\/strong><\/td><\/tr>\n\n<tr><td colspan=\"3\"><strong>\u5916\u673a\u53c2\u6570<\/strong><\/td><\/tr>\n<tr><td>\u578b\u53f7<\/td><td><strong>RAS-224HRNBQ<\/strong><\/td><td><strong>RAS-224FSXPN5Q<\/strong><\/td><\/tr>\n<tr><td>\u5236\u51b7 \/ \u5236\u70ed<\/td><td>22.4 kW \/ 25.0 kW<\/td><td>22.4 kW \/ 25.0 kW<\/td><\/tr>\n<tr><td>\u538b\u7f29\u673a<\/td><td>\u53d8\u9891\u53cc\u8f6c\u5b50<\/td><td>\u8865\u6c14\u589e\u7113\u53d8\u9891<\/td><\/tr>\n<tr><td>\u80fd\u6548 APF<\/td><td><strong>5.0\uff08\u8d85\u4e00\u7ea7\u80fd\u6548\uff09<\/strong><\/td><td>\u2014<\/td><\/tr>\n<tr><td>\u8fd0\u884c\u566a\u97f3<\/td><td>58 \/ 60 dB\uff08\u591c\u95f4 50\uff09<\/td><td>56 \/ 58 dB<\/td><\/tr>\n<tr><td>\u5916\u5f62\u5c3a\u5bf8<\/td><td>1380 \u00d7 950 \u00d7 320 mm<\/td><td>1380 \u00d7 950 \u00d7 370 mm<\/td><\/tr>\n<tr><td>\u51c0\u91cd<\/td><td>122 kg<\/td><td>\u2014<\/td><\/tr>\n<tr><td>\u53ef\u63a5\u5185\u673a<\/td><td>\u6700\u591a 12 \u53f0<\/td><td>\u6700\u591a 15 \u53f0<\/td><\/tr>\n<tr><td>\u914d\u7ba1\u603b\u957f<\/td><td>200 m<\/td><td>\u2014<\/td><\/tr>\n<tr><td>\u7535\u6e90 \/ \u5f85\u673a<\/td><td>\u5f85\u673a 1 W \u4e0d\u8d39\u7535<\/td><td>220 V<\/td><\/tr>\n<tr><td>\u53ef\u6269\u5c55<\/td><td>\u2014<\/td><td>\u53ef\u914d\u6c34\u6a21\u5757\uff08\u540e\u7eed\u53ef\u52a0\u5730\u6696\uff09<\/td><\/tr>\n\n<tr><td colspan=\"3\"><strong>\u5185\u673a\u53c2\u6570<\/strong><\/td><\/tr>\n<tr><td>\u7cfb\u5217<\/td><td><strong>RPIZ-\u25a1FSNAQD\/P<\/strong><\/td><td><strong>\u5168\u6548\u4e24\u7ba1\u5236\u5185\u673a\uff08\u901a\u7528\uff09<\/strong><\/td><\/tr>\n<tr><td>\u672c\u6b21\u914d\u7f6e<\/td><td>50 \u578b \u00d72 \u00b7 28 \u578b \u00d72 \u00b7 32 \u578b \u00b7 25 \u578b \u00b7 18 \u578b \u00b7 40 \u578b<\/td><td>50 \u578b \u00d72 \u00b7 28 \u578b \u00d72 \u00b7 32 \u578b \u00b7 25 \u578b \u00b7 18 \u578b \u00b7 40 \u578b<\/td><\/tr>\n<tr><td>\u7ba1\u5236\u65b9\u5f0f<\/td><td><strong>\u4e24\u7ba1\u5236<\/strong><\/td><td><strong>\u4e24\u7ba1\u5236<\/strong><\/td><\/tr>\n<tr><td>\u7c7b\u578b<\/td><td>\u8584\u578b DC \u6807\u51c6\u98ce\u7ba1\u673a<\/td><td>\u8584\u578b DC \u6807\u51c6\u98ce\u7ba1\u673a<\/td><\/tr>\n<tr><td>\u673a\u8eab\u539a\u5ea6<\/td><td><strong>192 mm\uff08\u540a\u9876\u4e0d\u538b\u6291\uff09<\/strong><\/td><td><strong>192 mm\uff08\u540a\u9876\u4e0d\u538b\u6291\uff09<\/strong><\/td><\/tr>\n<tr><td>\u6700\u4f4e\u9759\u97f3<\/td><td><strong>17 dB<\/strong><\/td><td><strong>17 dB<\/strong><\/td><\/tr>\n<tr><td>\u8c03\u8282<\/td><td>\u5168\u76f4\u6d41\u53d8\u9891 + 2000 \u7ea7\u7535\u5b50\u81a8\u80c0\u9600<\/td><td>\u5168\u76f4\u6d41\u53d8\u9891 + 2000 \u7ea7\u7535\u5b50\u81a8\u80c0\u9600<\/td><\/tr>\n<tr><td>\u5b89\u5168<\/td><td>\u6807\u914d\u6c34\u6cf5 + \u6d6e\u5b50\u5f00\u5173\uff08\u9632\u6ce1\u9876\uff09<\/td><td>\u6807\u914d\u6c34\u6cf5 + \u6d6e\u5b50\u5f00\u5173\uff08\u9632\u6ce1\u9876\uff09<\/td><\/tr>\n<tr><td>\u81ea\u6e05\u6d01<\/td><td>\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01 + 60\u2103 \u9664\u83cc<\/td><td>\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01 + 60\u2103 \u9664\u83cc<\/td><\/tr>\n<tr><td>\u6781\u7aef\u5de5\u51b5<\/td><td>52\u2103 \u9ad8\u6e29\u7a33\u8fd0\u884c \/ 45\u2103 \u5236\u51b7\u4e0d\u8870\u51cf<\/td><td>52\u2103 \u9ad8\u6e29\u7a33\u8fd0\u884c \/ 45\u2103 \u5236\u51b7\u4e0d\u8870\u51cf<\/td><\/tr>\n<tr><td>\u5b89\u88c5\u9002\u5e94<\/td><td>\u914d\u7ba1\u9ad8\u5dee\u53ef\u8fbe <strong>30 m<\/strong>\uff0c\u591a\u697c\u5c42\u9002\u7528<\/td><td>\u914d\u7ba1\u9ad8\u5dee <strong>30 \/ 50 m<\/strong>\uff0c\u591a\u697c\u5c42\u9002\u7528<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p><strong>\u5b89\u88c5\u5305\u542b\u4ec0\u4e48\uff1a<\/strong>\u542b\u8f85\u6750\u3001\u4eba\u5de5\uff0c<strong>\u542b\u76d1\u7406<\/strong>\uff0c<strong>\u542b\u4e24\u5c0f\u65f6\u4ee5\u4e0a\u62bd\u771f\u7a7a<\/strong>\u3002\u4e0d\u542b\u571f\u5efa\u3001\u5f00\u5b54\u3001\u7535\u6e90\u6539\u9020\u7b49\u73b0\u573a\u589e\u9879\u3002<\/p>\n\n<p><strong>\u600e\u4e48\u9009\uff1a<\/strong>\u5bb6\u91cc\u540c\u65f6\u5f00\u7684\u5185\u673a\u5c11\uff08\u5e73\u65f6\u4e5f\u5c31\u4e24\u4e09\u95f4\uff09\uff0c\u65b9\u6848\u4e00\u8212\u4eab\u66f4\u7701\u7535\uff1b\u540c\u5f00\u591a\u3001\u5bf9\u5236\u70ed\u8981\u6c42\u66f4\u786c\uff08\u6bd4\u65b9\u8bf4\u5bb6\u91cc\u5e38\u4f4f\u7684\u623f\u95f4\u591a\u3001\u51ac\u5929\u5f00\u5f97\u591a\uff09\uff0c\u65b9\u6848\u4e8c\u5c0a\u777f\u5168\u6548\u66f4\u5408\u9002\u3002\u4e24\u5957\u7684\u5185\u673a\u5b8c\u5168\u4e00\u6837\uff0c\u6240\u4ee5\u5dee\u522b\u53ea\u5728\u4e3b\u673a\u8fd9\u4e00\u5904\u3002<\/p>\n\n<p><strong>\u4e3a\u4ec0\u4e48\u4e0d\u628a\u4ef7\u683c\u5199\u5728\u8fd9\u4e00\u9875\u4e0a\uff1a<\/strong>\u6bcf\u6237\u7684\u5c42\u9ad8\u3001\u7ed3\u6784\u3001\u7ba1\u8def\u8d70\u5411\u3001\u5916\u5899\u6761\u4ef6\u90fd\u4e0d\u4e00\u6837\uff0c\u540c\u4e00\u53f0\u673a\u5668\u88c5\u5728\u4e0d\u540c\u623f\u5b50\u91cc\uff0c\u8f85\u6750\u3001\u540a\u67b6\u3001\u6253\u5b54\u3001\u4eba\u5de5\u7684\u91cf\u5dee\u5f97\u8fdc\u3002\u62a5\u4ef7\u5fc5\u987b\u6309\u73b0\u573a\u52d8\u6d4b\u7b97\uff0c\u4e5f\u6b22\u8fce\u62ff\u7740\u6211\u4eec\u51fa\u7684\u62a5\u4ef7\u53bb\u6bd4\u2014\u2014\u4ef7\u683c\u4e0d\u85cf\uff0c\u4f46\u4e0d\u5728\u8fd9\u7c7b\u6587\u7ae0\u91cc\u62cd\u4e00\u4e2a\u6570\u5b57\uff0c\u514d\u5f97\u540c\u6237\u578b\u7684\u4e1a\u4e3b\u7167\u7740\u4e00\u4e2a\u4e0d\u51c6\u7684\u6570\u53bb\u8c08\u3002<\/p>\n\n<h2>\u4e5d\u3001\u4e24\u4e2a\u5df2\u7ecf\u4f4f\u8fdb\u53bb\u7684\u5ba2\u6237\u5bb6<\/h2>\n\n<h3>\u6848\u4f8b\u4e00 \u00b7 \u548c\u8d35\u5357\u5c71 \u00b7 \u8f9b\u603b\u5bb6\uff08600 \u33a1 \u522b\u5885\uff09<\/h3>\n\n<p>2020 \u5e74\u88c5\u4fee\uff0c\u8f9b\u603b\u5728\u88c5\u4e2d\u592e\u7a7a\u8c03\u3001\u65b0\u98ce\u3001\u5730\u6696\u7684\u540c\u65f6\uff0c\u628a\u5168\u5c4b\u7ed9\u6c34\u70ed\u6c34\u4e5f\u4ea4\u7ed9\u6211\u4eec\u4e00\u4f53\u5316\u8bbe\u8ba1\u3002<\/p>\n\n<ul>\n<li>\u7a7a\u8c03\uff0b\u65b0\u98ce\uff0b\u5730\u6696\uff0b300 L \u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668\uff0c<strong>\u4e00\u5957\u7cfb\u7edf\u6574\u4f53\u8bbe\u8ba1<\/strong>\uff0c\u800c\u4e0d\u662f\u5404\u5bb6\u7ba1\u5404\u5bb6\u7684\uff1b<\/li>\n<li>\u7ba1\u8def\u7528\u4f1f\u661f A+ \u7ba1\uff0c\u536b\u751f\u95f4\u7528\u6c34\u70b9<strong>\u65e0\u63a5\u5934<\/strong>\uff1b\u6bcf\u5c42\u70ed\u6c34\u5355\u72ec\u56de\u8def\uff0c\u51e0\u5904\u540c\u65f6\u7528\u6c34\u4e0d\u62a2\u6c34\uff1b<\/li>\n<li>\u70ed\u6c34\u5faa\u73af\u53ea\u505a\u4e3b\u7ba1\u5faa\u73af\u3001\u4e0d\u505a\u652f\u7ba1\u5faa\u73af\u2014\u2014<strong>\u5373\u5f00\u5373\u70ed\uff0c\u53c8\u4e0d\u9760\u5faa\u73af\u6cf5\u4e00\u76f4\u8dd1<\/strong>\u3002<\/li>\n<\/ul>\n\n<p><strong>\u4f7f\u7528\u51e0\u5e74\u7684\u5b9e\u6d4b\u53cd\u9988\uff1a<\/strong>300 L \u70ed\u6c34\u5668\u4f7f\u7528\u8d39\u4e0d\u5230 200 \u5143\/\u6708\uff08\u8fd8\u5305\u62ec\u5bb6\u91cc\u505a\u996d\u7528\u6c14\uff09\uff1b24 \u5c0f\u65f6\u70ed\u6c34\u5373\u5f00\u5373\u70ed\uff1b\u4e94\u697c\u70ed\u6c34\u538b\u529b\u6b63\u5e38\uff0c\u5927\u9876\u55b7\u7167\u7528\u3002\u4f1f\u661f\u5382\u5bb6\u4eb2\u81ea\u6765\u9a8c\u6536\uff0c\u90fd\u8bf4\u8fd9\u4e2a\u7cfb\u7edf\u7684\u5de5\u827a\u5c11\u89c1\u3002\u4e1a\u4e3b\u81ea\u5df1\u8bb2\u7684\u4e00\u53e5\u8bdd\u662f\uff1a\u300c\u6211\u4eec\u7684\u6574\u4f53\u7ba1\u8def\u7cfb\u7edf\u8bbe\u8ba1\u5f97\u597d\uff0c\u65bd\u5de5\u4fdd\u6e29\u505a\u5f97\u597d\u3002\u300d<\/p>\n\n<p><strong>\u8fd9\u6237\u540e\u6765\u8fd8\u6709\u4e00\u4e2a\u66f4\u503c\u94b1\u7684\u590d\u76d8\uff1a<\/strong>\u7a7a\u8c03\u8fd9\u5757\uff0c\u4e1a\u4e3b\u5165\u4f4f\u4e24\u5e74\u540e\u81ea\u5df1\u8ddf\u6211\u8bb2\uff0c\u5f53\u521d\u53ef\u4ee5\u5c11\u914d 5\uff5e6 \u53f0\u5185\u673a\u3001\u4e3b\u673a\u4e5f\u80fd\u5f80\u4e0b\u964d\u4e00\u6863\uff0c\u529f\u7387\u662f\u8fc7\u5269\u7684\u3002\u539f\u56e0\u4e0d\u590d\u6742\u2014\u2014\u5f00\u5de5\u524d\u6211\u4eec\u53cd\u590d\u5efa\u8bae\u6309\u9700\u914d\uff0c\u4e1a\u4e3b\u5f53\u65f6\u6309\u300c\u6bcf\u5e73\u65b9\u914d\u5927\u4e00\u70b9\u66f4\u4fdd\u9669\u300d\u7684\u901a\u884c\u7684 200 W\/\u33a1 \u914d\u4e86\u3002\u4ed6\u590d\u76d8\u7684\u539f\u8bdd\u5927\u610f\u662f\uff1a<strong>\u5f53\u521d\u5e94\u8be5\u542c\u4f60\u4eec\u7684\u914d\u7f6e\u5efa\u8bae\u3002<\/strong>\u8fd9\u4e00\u6761\u6211\u4eec\u4e00\u76f4\u8bb0\u7740\uff0c\u4e5f\u662f\u8fd9\u4e00\u9875\u8981\u8bb2\u300c\u6309\u623f\u95f4\u6838\u3001\u4e0d\u6309\u9762\u79ef\u4e58\u7cfb\u6570\u300d\u7684\u7531\u6765\u3002<\/p>\n\n<h3>\u6848\u4f8b\u4e8c \u00b7 \u4e2d\u6d77\u4e5d\u53f7\u516c\u9986 \u00b7 \u738b\u603b\u5bb6\uff08200 \u33a1 \u5927\u5e73\u5c42\uff09<\/h3>\n\n<p>\u6210\u90fd\u6b66\u4faf\u4e2d\u6d77\u4e5d\u53f7\u516c\u9986\uff0c200 \u33a1 \u7cbe\u88c5\u5927\u5e73\u5c42\uff0c\u5e38\u4f4f 6\u20147 \u4eba\uff08\u4e09\u5b69\uff0b\u4fdd\u59c6\uff09\u3002\u8fd9\u5957\u623f\u662f<strong>\u63d0\u524d\u8bbe\u8ba1<\/strong>\u7684\u2014\u2014\u88c5\u4fee\u8fd8\u6ca1\u8fdb\u573a\uff0c\u65b9\u6848\u5c31\u5b9a\u4e0b\u6765\u4e86\uff0c\u6240\u4ee5\u914d\u7f6e\u80fd\u6309\u6bcf\u4e00\u95f4\u623f\u7684\u771f\u5b9e\u8d1f\u8377\u6765\u5b9a\uff0c\u4e0d\u7528\u8fc1\u5c31\u5df2\u6210\u578b\u7684\u540a\u9876\u548c\u7ba1\u8def\u3002<\/p>\n\n<table>\n<thead>\n<tr><th>\u7a7a\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u53f0\u6570<\/th><th>\u51b7\u91cf\uff08W\uff09<\/th><th>\u51b7\u6307\u6807\uff08W\/\u33a1\uff09<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>\u5ba2\u9910\u5385<\/td><td>85.61 \u33a1<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1<\/td><td>7,100<\/td><td>83<\/td><\/tr>\n<tr><td>\u4e3b\u5367<\/td><td>23.80 \u33a1<\/td><td>RPIZ-45FSVN2QB\/PC<\/td><td>1<\/td><td>4,500<\/td><td>189<\/td><\/tr>\n<tr><td>\u513f\u7ae5\u623f 1<\/td><td>13.38 \u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>1<\/td><td>2,200<\/td><td>164<\/td><\/tr>\n<tr><td>\u513f\u7ae5\u623f 2<\/td><td>13.19 \u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>1<\/td><td>2,200<\/td><td>167<\/td><\/tr>\n<tr><td>\u513f\u7ae5\u623f 3<\/td><td>16.63 \u33a1<\/td><td>RPIZ-28FSVN2QB\/PC<\/td><td>1<\/td><td>2,800<\/td><td>168<\/td><\/tr>\n<tr><td>\u5ba2\u623f<\/td><td>11.29 \u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>1<\/td><td>2,200<\/td><td>\u7ea6 195<\/td><\/tr>\n<tr><td>\u5408\u8ba1<\/td><td>\u2014<\/td><td>6 \u53f0 \u00b7 \u603b\u51b7\u91cf 25.0 kW<\/td><td><strong>6<\/strong><\/td><td><strong>25,000<\/strong><\/td><td>\u2014<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p>\u6700\u503c\u5f97\u8bf4\u7684\u662f<strong>\u5ba2\u9910\u5385 85.61 \u33a1 \u53ea\u7528\u4e86\u4e00\u53f0 71 \u578b\u5185\u673a<\/strong>\u300285 \u33a1 \u7684\u5ba2\u9910\u5385\uff0c\u6309\u300c\u9762\u79ef\u4e58\u7cfb\u6570\u300d\u7684\u7b97\u6cd5\u5f88\u5bb9\u6613\u914d\u5230\u4e24\u4e09\u53f0\uff1b\u8fd9\u6237\u6309\u56fd\u6807\u8d1f\u8377\u6838\u51fa\u6765\u662f <strong>83 W\/\u33a1<\/strong>\uff0c\u4e00\u53f0\u5c31\u591f\u3002\u4e3b\u673a\u7528 RAS-224FSXPN5Q\uff08\u8865\u6c14\u589e\u7113\u6da1\u65cb\uff09\uff0c<strong>\u8fde\u63a5\u7387 111.6%<\/strong>\uff0c\u843d\u5728\u5408\u7406\u533a\u95f4\u91cc\uff0c\u4e0d\u505a\u6ca1\u5fc5\u8981\u7684\u52a0\u7801\u3002\u8fd9\u5957\u623f\u7684\u5730\u6696\u505a\u4e86 192 \u33a1\u300112 \u56de\u8def\uff0c\u662f\u53e6\u4e00\u5957\u7cfb\u7edf\u7684\u4e8b\uff0c\u90a3\u6237\u4e1a\u4e3b\u4e5f\u505a\u4e86\u4e09\u8054\u4f9b\u3002<\/p>\n\n<blockquote>\n<p>\u4e24\u6237\u653e\u5728\u4e00\u8d77\u770b\uff1a\u4e00\u6237\u662f<strong>\u4e8b\u540e\u590d\u76d8<\/strong>\u53d1\u73b0\u5f53\u521d\u914d\u5927\u4e86\uff0c\u4e00\u6237\u662f<strong>\u4e8b\u524d\u8bbe\u8ba1<\/strong>\u5c31\u6309\u623f\u95f4\u6838\u5230\u4f4d\u3002\u5dee\u522b\u4e0d\u5728\u673a\u5668\u597d\u4e0d\u597d\uff0c\u5728<strong>\u914d\u7f6e\u662f\u600e\u4e48\u7b97\u51fa\u6765\u7684<\/strong>\u3002<\/p>\n<\/blockquote>\n\n<h2>\u5341\u3001\u628a\u8bdd\u8bf4\u660e\u767d<\/h2>\n\n<p>\u8fd9\u4efd\u65b9\u6848\u662f\u7ed9\u4e00\u4f4d\u4e1a\u4e3b\u505a\u7684\uff0c\u516c\u5f00\u51fa\u6765\uff0c\u662f\u56e0\u4e3a\u5b83\u628a\u4e24\u4ef6\u5bb9\u6613\u88ab\u8df3\u8fc7\u7684\u4e8b\u5199\u5168\u4e86\uff1a<strong>\u4e00\u662f\u300c\u54ea\u4e9b\u533a\u57df\u91c7\u6696\u624d\u6709\u6548\u300d\uff0c\u4e8c\u662f\u300c\u914d\u7f6e\u5230\u5e95\u600e\u4e48\u7b97\u51fa\u6765\u7684\u300d<\/strong>\u3002\u540c\u6237\u578b\u7684\u4e1a\u4e3b\u62ff\u7740\u5b83\uff0c\u53bb\u8ddf\u4efb\u4f55\u4e00\u5bb6\u7684\u65b9\u6848\u5bf9\u7167\uff0c\u90fd\u5bf9\u7167\u5f97\u8d77\u6765\u3002<\/p>\n\n<p>\u6211\u4eec\u53ea\u575a\u6301\u4e00\u6761\uff1a<strong>\u94b1\u8981\u82b1\u5728\u6709\u6548\u7684\u5730\u65b9\u3002<\/strong>\u8fd9\u5957\u623f\u4e0d\u505a\u5730\u6696\uff0c\u7a7a\u8c03\u51ac\u5929\u8981\u62c5\u91c7\u6696\uff0c\u8fd9\u4e00\u70b9\u6211\u4eec\u6309 5 \u4e2a\u623f\u95f4\u5355\u72ec\u6838\u7b97\u8fc7\uff0c\u4e3b\u673a 25 kW \u5236\u70ed\u4f59\u91cf\u5145\u8db3\uff1b\u800c\u516c\u533a\uff08\u5ba2\u9910\u5385\u3001\u5f71\u5385\uff09\u56db\u5c42\u5e26\u697c\u68af\u95f4\uff0c\u91c7\u6696\u672c\u6765\u5c31\u7559\u4e0d\u4f4f\u70ed\uff0c\u5728\u90a3\u91cc\u52a0\u914d\u7f6e\u662f\u767d\u82b1\u94b1\u2014\u2014\u8fd9\u4e00\u6761\u6211\u4eec\u4e5f\u5982\u5b9e\u5199\u5728\u65b9\u6848\u91cc\uff0c\u5e76\u7ed9\u4e86\u66ff\u4ee3\u505a\u6cd5\u3002<\/p>\n\n<p>\u5982\u679c\u60a8\u5bb6\u7684\u623f\u5b50\u4e5f\u5728\u8fd9\u4e2a\u7ed3\u6784\u4e0a\uff08\u591a\u697c\u5c42\u3001\u516c\u533a\u8d2f\u901a\u3001\u4e0d\u505a\u5730\u6696\uff09\uff0c\u6b22\u8fce\u628a\u8fd9\u5957\u7b97\u6cd5\u62ff\u53bb\u7528\uff1a<strong>\u5148\u5206\u533a\u57df\u5b9a\u91c7\u6696\u8303\u56f4\uff0c\u518d\u6309\u623f\u95f4\u6838\u5236\u51b7\uff0c\u6700\u540e\u624d\u8c08\u914d\u591a\u5927\u3002<\/strong>\u7b97\u5b8c\u5982\u679c\u53d1\u73b0\u60a8\u5bb6\u90a3\u4efd\u65b9\u6848\u8ddf\u8fd9\u4e2a\u8def\u5b50\u5bf9\u4e0d\u4e0a\uff0c\u4e5f\u6b22\u8fce\u628a\u56fe\u7eb8\u548c\u65b9\u6848\u62ff\u6765\uff0c\u6211\u4eec\u6309\u540c\u4e00\u5957\u65b9\u6cd5\u5e2e\u60a8\u590d\u6838\u4e00\u904d\uff0c<strong>\u8d1f\u8377\u8ba1\u7b97\u4e66\u548c\u8ba1\u7b97\u8fc7\u7a0b\u53ef\u4ee5\u5f53\u9762\u8fc7\u7ed9\u4f60\u4eec\u770b<\/strong>\uff0c\u5236\u51b7\u3001\u91c7\u6696\u4e24\u4fa7\u90fd\u7b97\u3002<\/p>\n\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n\n<h3>\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u53ea\u914d 8 \u53f0\u5185\u673a\uff0c\u4f1a\u4e0d\u4f1a\u4e0d\u591f\u7528\uff1f<\/h3>\n\n<p>\u591f\uff0c\u800c\u4e14\u6709\u4f59\u91cf\u30028 \u53f0\u5185\u673a\u5408\u8ba1 27.1 kW\uff0c\u644a\u5230 141.79 \u33a1 \u4e0a\uff0c\u6bcf\u4e2a\u623f\u95f4\u914d\u7684\u5355\u4f4d\u51b7\u91cf\u5728 162~300 W\/\u33a1\uff0c\u90fd\u9ad8\u4e8e\u56fd\u6807\u5236\u51b7\u57fa\u51c6 80~120 W\/\u33a1\u3002\u5236\u51b7\u770b\u7684\u662f\u6bcf\u95f4\u623f\u7684\u8d1f\u8377\uff0c\u4e0d\u662f\u53f0\u6570\u591a\u4e0d\u591a\u2014\u2014\u53f0\u6570\u5c11\u4e0d\u7b49\u4e8e\u80fd\u529b\u5c0f\u3002<\/p>\n\n<h3>\u522b\u5885\u4e0d\u505a\u5730\u6696\uff0c\u51ac\u5929\u5168\u9760\u7a7a\u8c03\u91c7\u6696\u884c\u4e0d\u884c\uff1f<\/h3>\n\n<p>\u5c01\u95ed\u7684\u623f\u95f4\u884c\uff0c\u516c\u533a\u4e0d\u884c\u3002\u8fd9\u5957\u623f\u771f\u6b63\u9700\u8981\u91c7\u6696\u7684\u662f 5 \u95f4\u5367\u5ba4\uff0c\u9762\u79ef\u7ea6 63.4 \u33a1\uff0c\u6309\u504f\u9ad8\u7684 150~200 W\/\u33a1 \u7b97\u9700\u8981 9.5~12.7 kW\uff0c\u4e3b\u673a\u5236\u70ed 25 kW\uff0c\u591f\u3002\u4f46\u5ba2\u9910\u5385\u3001\u5f71\u5385\u8fd9\u7c7b\u548c\u697c\u68af\u95f4\u8d2f\u901a\u7684\u5730\u65b9\uff0c\u9760\u7a7a\u8c03\u91c7\u6696\u7559\u4e0d\u4f4f\u70ed\uff0c\u8fd9\u4e0d\u662f\u914d\u7f6e\u95ee\u9898\uff0c\u662f\u623f\u5b50\u7684\u7ed3\u6784\u51b3\u5b9a\u7684\u3002<\/p>\n\n<h3>\u5ba2\u9910\u5385\u3001\u5f71\u5385\u8fd9\u4e9b\u516c\u533a\uff0c\u4e3a\u4ec0\u4e48\u9760\u7a7a\u8c03\u91c7\u6696\u6548\u679c\u6709\u9650\uff1f<\/h3>\n\n<p>\u4e24\u4e2a\u539f\u56e0\u53e0\u5728\u4e00\u8d77\uff1a\u4e00\u662f\u7a7a\u8c03\u5236\u70ed\u662f\u5f80\u9876\u4e0a\u5f80\u4e0b\u5439\u70ed\u98ce\uff0c\u800c\u70ed\u98ce\u5929\u751f\u5f80\u4e0a\u6d6e\uff0c\u4e0d\u5bb9\u6613\u538b\u5230\u4eba\u5750\u7740\u7684\u9ad8\u5ea6\uff1b\u4e8c\u662f\u56db\u5c42\u5e26\u697c\u68af\u95f4\uff0c\u7ad6\u5411\u7a7a\u95f4\u8d2f\u901a\uff0c\u70ed\u6c14\u4f1a\u987a\u7740\u697c\u68af\u95f4\u5f80\u4e0a\u62bd\u3001\u4ece\u9876\u5c42\u6563\u6389\u3002\u70ed\u91cf\u8dd1\u6389\u4e86\uff0c\u4eba\u4e0d\u89c9\u5f97\u6696\uff0c\u7535\u8d39\u7167\u6da8\u3002<\/p>\n\n<h3>\u4ec0\u4e48\u662f\u70df\u56f1\u6548\u5e94\uff1f\u5bf9\u522b\u5885\u91c7\u6696\u5f71\u54cd\u6709\u591a\u5927\uff1f<\/h3>\n\n<p>\u70df\u56f1\u6548\u5e94\u5c31\u662f\u70ed\u7a7a\u6c14\u987a\u7740\u7ad6\u5411\u901a\u9053\u5f80\u4e0a\u8dd1\u3001\u4ece\u9ad8\u5904\u6563\u6389\u7684\u73b0\u8c61\u3002\u623f\u5b50\u697c\u5c42\u8d8a\u591a\u3001\u697c\u68af\u95f4\u8d8a\u8d2f\u901a\uff0c\u8fd9\u4e2a\u6548\u5e94\u8d8a\u660e\u663e\u3002\u5f71\u54cd\u662f\uff1a\u5728\u6311\u7a7a\u3001\u6709\u7ad6\u5411\u5f00\u53e3\u7684\u516c\u533a\uff0c\u5236\u70ed\u80fd\u529b\u52a0\u5f97\u518d\u5927\uff0c\u591a\u51fa\u6765\u7684\u70ed\u91cf\u5927\u90e8\u5206\u4f1a\u76f4\u63a5\u635f\u5931\u6389\uff0c\u6240\u4ee5\u90a3\u4e9b\u5730\u65b9\u4e0d\u8be5\u9760\u52a0\u7a7a\u8c03\u914d\u7f6e\u6765\u89e3\u51b3\u3002<\/p>\n\n<h3>\u4e2d\u592e\u7a7a\u8c03\u914d\u7f6e\u914d\u5927\u4e86\u4f1a\u6709\u4ec0\u4e48\u574f\u5904\uff1f<\/h3>\n\n<p>\u590f\u5929\u4f1a\u51fa\u95ee\u9898\u3002\u673a\u5668\u8fdc\u5927\u4e8e\u5b9e\u9645\u8d1f\u8377\uff0c\u623f\u95f4\u5f88\u5feb\u5c31\u5230\u6e29\uff0c\u7cfb\u7edf\u53ea\u9700\u8981\u5f88\u5c11\u51b7\u91cf\uff0c\u7535\u5b50\u81a8\u80c0\u9600\u5f00\u5ea6\u6781\u5c0f\u3001\u538b\u7f29\u673a\u5374\u8fd8\u5728\u8f6c\u2014\u2014\u7ed3\u679c\u662f\u566a\u97f3\u53d8\u5927\u3001\u623f\u95f4\u5ffd\u51b7\u5ffd\u70ed\u3001\u538b\u7f29\u673a\u9891\u7e41\u542f\u505c\u3002\u65e2\u8d39\u7535\uff0c\u53c8\u52a0\u901f\u90e8\u4ef6\u635f\u8017\u3001\u62ac\u9ad8\u6545\u969c\u7387\u3002\u6b64\u5916\u4e25\u91cd\u8d85\u914d\u65f6\u53ea\u5f00\u4e00\u95f4\u623f\uff0c\u4e00\u4e2a\u590f\u5929\u7684\u7535\u8d39\u53ef\u80fd\u6bd4\u79d1\u5b66\u914d\u7f6e\u591a\u51fa 30%~50%\u3002<\/p>\n\n<h3>\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u4e3b\u673a\u600e\u4e48\u9009\uff0c\u53cc\u8f6c\u5b50\u548c\u8865\u6c14\u589e\u7113\u6da1\u65cb\u5dee\u5728\u54ea\uff1f<\/h3>\n\n<p>\u770b\u5e73\u65f6\u540c\u65f6\u5f00\u51e0\u53f0\u3002\u5bb6\u91cc\u4e60\u60ef\u53ea\u5f00\u4e24\u4e09\u95f4\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff08\u8212\u4eab\u7cfb\u5217\uff09\u5728\u540c\u5f00\u5c11\u7684\u65f6\u5019\u66f4\u7701\u7535\uff1b\u5e38\u4f4f\u7684\u623f\u95f4\u591a\u3001\u7ecf\u5e38\u56db\u4e94\u53f0\u4e00\u8d77\u5f00\uff0c\u8865\u6c14\u589e\u7113\u6da1\u65cb\uff08\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff09\u5728\u540c\u5f00\u591a\u7684\u65f6\u5019\u66f4\u7701\u7535\u3001\u5236\u70ed\u66f4\u7a33\u3002\u4e24\u8005\u5236\u51b7\u5236\u70ed\u91cf\u90fd\u662f 22.4 \/ 25.0 kW\uff0c\u5185\u673a\u4e5f\u4e00\u6837\uff0c\u5dee\u522b\u53ea\u5728\u4e3b\u673a\u3002<\/p>\n\n<h3>\u7cbe\u88c5\u623f\u5728\u5efa\uff0c\u4e2d\u592e\u7a7a\u8c03\u4ec0\u4e48\u65f6\u5019\u8fdb\u573a\u6700\u5408\u9002\uff1f<\/h3>\n\n<p>\u8d8a\u65e9\u8d8a\u597d\uff0c\u6700\u597d\u8d76\u5728\u7cbe\u88c5\u5de5\u5e8f\u8fdb\u573a\u4e4b\u524d\u3002\u4e2d\u592e\u7a7a\u8c03\u7684\u5185\u673a\u3001\u7ba1\u8def\u3001\u51b7\u51dd\u6c34\u7ba1\u90fd\u8981\u85cf\u5728\u540a\u9876\u91cc\uff0c\u5c5e\u4e8e\u9690\u853d\u5de5\u7a0b\uff0c\u5fc5\u987b\u5728\u540a\u9876\u5c01\u677f\u4e4b\u524d\u505a\u5b8c\u3002\u7b49\u5230\u7cbe\u88c5\u8d34\u7816\u3001\u540a\u9876\u5b9a\u578b\u518d\u56de\u5934\u6539\uff0c\u4ee3\u4ef7\u5f88\u5927\u3002\u6240\u4ee5\u7cbe\u88c5\u623f\u62ff\u5230\u56fe\u7eb8\u5c31\u53ef\u4ee5\u5148\u5b9a\u65b9\u6848\uff0c\u52d8\u6d4b\u548c\u5b9a\u6848\u4e0d\u5fc5\u7b49\u88c5\u4fee\u961f\u8fdb\u573a\u3002<\/p>\n\n<h3>\u6210\u90fd\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u5927\u6982\u591a\u5c11\u94b1\uff1f<\/h3>\n\n<p>\u6309\u73b0\u573a\u52d8\u6d4b\u51fa\u6765\u7684\u5b9e\u9645\u5de5\u7a0b\u91cf\u62a5\uff0c\u4e0d\u6309\u9762\u79ef\u4f30\u3002\u540c\u4e00\u53f0\u673a\u5668\u88c5\u5728\u4e0d\u540c\u623f\u5b50\u91cc\uff0c\u4e2d\u95f4\u7684\u8f85\u6750\u3001\u540a\u67b6\u3001\u6253\u5b54\u3001\u7ba1\u8def\u957f\u5ea6\u3001\u4eba\u5de5\u91cf\u90fd\u4e0d\u4e00\u6837\uff1b\u4e24\u5957\u4e3b\u673a\u65b9\u6848\uff08\u8212\u4eab \/ \u5c0a\u777f\u5168\u6548\uff09\u672c\u8eab\u4e5f\u6709\u5dee\u4ef7\u3002\u6240\u4ee5\u62a5\u4ef7\u6211\u4eec\u5355\u72ec\u51fa\u3001\u5199\u6e05\u695a\u6bcf\u4e00\u9879\uff0c\u4e5f\u6b22\u8fce\u62ff\u7740\u53bb\u6bd4\u3002<\/p>\n\n<h2>\u627e\u9f99\u8109\u6696\u901a<\/h2>\n\n<p>\u4e24\u5bb6\u5e97\u90fd\u5728\u5bcc\u68ee\u7f8e\uff0c\u53ef\u4ee5\u5230\u5e97\u770b\u5b9e\u7269\u3001\u770b\u7ba1\u8def\u505a\u6cd5\u3002\u4e0a\u95e8\u52d8\u6d4b\u4e0d\u6536\u8d39\uff0c\u51fa\u4e66\u9762\u65b9\u6848\u548c\u9010\u623f\u8d1f\u8377\u8ba1\u7b97\u4e66\uff0c\u60a8\u62ff\u7740\u53bb\u6bd4\u4ef7\u4e5f\u884c\u3002\u60f3\u5148\u7535\u8bdd\u804a\uff0c\u4e24\u4e2a\u95e8\u5e97\u7684\u8d1f\u8d23\u4eba\u76f4\u63a5\u5bf9\u63a5\uff08\u5fae\u4fe1\u540c\u53f7\uff09\uff1a<\/p>\n\n<ul>\n<li><strong>\u5357\u5bcc\u68ee \u00b7 \u9ad8\u65b0\u5e97<\/strong>\uff08\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B \/ A348\uff09\uff5c \u70ed\u7ebf <a href=\"tel:02886131795\">028-86131795<\/a> \uff5c \u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a> \uff5c <a href=\"https:\/\/j.map.baidu.com\/92\/wW9c\" target=\"_blank\" rel=\"noopener\">\u5730\u56fe\u5bfc\u822a<\/a><\/li>\n<li><strong>\u5317\u5bcc\u68ee \u00b7 \u6210\u534e\u5e97<\/strong>\uff08\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135\uff09\uff5c \u70ed\u7ebf <a href=\"tel:02865272586\">028-65272586<\/a> \uff5c \u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a> \uff5c <a href=\"https:\/\/j.map.baidu.com\/df\/8hAi\" target=\"_blank\" rel=\"noopener\">\u5730\u56fe\u5bfc\u822a<\/a><\/li>\n<\/ul>\n\n<h2>\u63a5\u7740\u5f80\u4e0b\u770b<\/h2>\n\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13419\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009<\/a> \u2014\u2014 \u6309\u623f\u95f4\u6838\u3001\u6309\u8d1f\u8377\u7b97\u7684\u5b8c\u6574\u65b9\u6cd5<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=11380\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6<\/a> \u2014\u2014 \u8fd9\u5957\u65b9\u6848\u843d\u5730\u65f6\uff0c\u5c01\u677f\u524d\u6309\u4ec0\u4e48\u6807\u51c6\u9010\u6761\u9a8c\u6536<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66<\/a> \u2014\u2014 \u70df\u56f1\u6548\u5e94\u3001\u516c\u533a\u4e0d\u52a0\u5927\u3001\u540c\u5f00\u7387\uff0c\u6280\u672f\u4f9d\u636e\u90fd\u5728\u8fd9\u91cc<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=448\">\u548c\u8d35\u5357\u5c71\u8f9b\u603b\u5bb6\u6848\u4f8b<\/a> \u2014\u2014 600 \u33a1 \u522b\u5885\uff0c\u5165\u4f4f\u4e24\u5e74\u540e\u7684\u8d85\u914d\u590d\u76d8<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=6153\">\u4e2d\u6d77\u4e5d\u53f7\u516c\u9986\u738b\u603b\u5bb6\u6848\u4f8b<\/a> \u2014\u2014 200 \u33a1 \u5927\u5e73\u5c42\uff0c\u5ba2\u9910\u5385 85 \u33a1 \u53ea\u7528\u4e00\u53f0\u5185\u673a<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12447\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/a> \u2014\u2014 \u516c\u533a\u8865\u91c7\u6696\u3001\u677f\u5f0f\u4e0e\u67f1\u5f0f\u600e\u4e48\u9009<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3<\/a> \u2014\u2014 \u66f4\u591a\u6210\u90fd\u5bb6\u5ead\u7684\u5b8c\u6574\u8bb0\u5f55<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=14150\">\u5c0a\u777f\u5168\u6548\u5230\u5e95\u503c\u4e0d\u503c\u5f97\u4e70<\/a> \u2014\u2014 \u9002\u5408\u8c01\u3001\u8d35\u5728\u54ea\u3001\u8ddf\u5927\u91d1\u683c\u529b\u600e\u4e48\u6bd4\u3001\u6210\u90fd\u591a\u5c11\u94b1<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=5849\">\u6210\u90fd\u65e5\u7acb\u6696\u901a\u5ba2\u6237\u65b9\u6848\u805a\u5408<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13471\">\u6210\u90fd\u5730\u6696\u65b9\u6848\u4e94\u6b65\u6cd5\u516c\u5f00\u7248<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13579\">\u4e2d\u592e\u7a7a\u8c03\u6c1f\u7cfb\u7edf\u65b9\u6848\u4e94\u6b65\u6cd5<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>\u4e00\u3001\u5148\u628a\u8fd9\u4efd\u65b9\u6848\u7684\u6765\u9f99\u53bb\u8109\u8bf4\u6e05\u695a \u8fd9\u662f  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-14114","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u516c\u5f00\u7248\uff1a\u4e0d\u505a\u5730\u6696\u3001\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u5236\u51b7\u91c7\u6696\u5206\u5f00\u6838\u7b97\u3002\u70df\u56f1\u6548\u5e94\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u8bb2\u900f\uff0c\u9644\u9010\u623f\u95f4\u6838\u7b97\u8868\u3001\u4e24\u5957\u4e3b\u673a\u5bf9\u7167\u4e0e\u771f\u5b9e\u6848\u4f8b\u3002\u7cbe\u88c5\u623f\u62a2\u5728\u88c5\u4fee\u8fdb\u573a\u524d\u505a\u9690\u853d\u5de5\u7a0b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=14114\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u516c\u5f00\u7248\uff1a\u4e0d\u505a\u5730\u6696\u3001\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u5236\u51b7\u91c7\u6696\u5206\u5f00\u6838\u7b97\u3002\u70df\u56f1\u6548\u5e94\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u8bb2\u900f\uff0c\u9644\u9010\u623f\u95f4\u6838\u7b97\u8868\u3001\u4e24\u5957\u4e3b\u673a\u5bf9\u7167\u4e0e\u771f\u5b9e\u6848\u4f8b\u3002\u7cbe\u88c5\u623f\u62a2\u5728\u88c5\u4fee\u8fdb\u573a\u524d\u505a\u9690\u853d\u5de5\u7a0b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=14114\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-14T06:34:41+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14114\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14114\",\"name\":\"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-10-07T07:09:22+00:00\",\"dateModified\":\"2026-10-14T06:34:41+00:00\",\"description\":\"\u6210\u90fd\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u516c\u5f00\u7248\uff1a\u4e0d\u505a\u5730\u6696\u3001\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u5236\u51b7\u91c7\u6696\u5206\u5f00\u6838\u7b97\u3002\u70df\u56f1\u6548\u5e94\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u8bb2\u900f\uff0c\u9644\u9010\u623f\u95f4\u6838\u7b97\u8868\u3001\u4e24\u5957\u4e3b\u673a\u5bf9\u7167\u4e0e\u771f\u5b9e\u6848\u4f8b\u3002\u7cbe\u88c5\u623f\u62a2\u5728\u88c5\u4fee\u8fdb\u573a\u524d\u505a\u9690\u853d\u5de5\u7a0b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14114#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14114\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14114#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u516c\u5f00\u7248\uff1a\u4e0d\u505a\u5730\u6696\u3001\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u5236\u51b7\u91c7\u6696\u5206\u5f00\u6838\u7b97\u3002\u70df\u56f1\u6548\u5e94\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u8bb2\u900f\uff0c\u9644\u9010\u623f\u95f4\u6838\u7b97\u8868\u3001\u4e24\u5957\u4e3b\u673a\u5bf9\u7167\u4e0e\u771f\u5b9e\u6848\u4f8b\u3002\u7cbe\u88c5\u623f\u62a2\u5728\u88c5\u4fee\u8fdb\u573a\u524d\u505a\u9690\u853d\u5de5\u7a0b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=14114","og_locale":"zh_CN","og_type":"article","og_title":"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u516c\u5f00\u7248\uff1a\u4e0d\u505a\u5730\u6696\u3001\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u5236\u51b7\u91c7\u6696\u5206\u5f00\u6838\u7b97\u3002\u70df\u56f1\u6548\u5e94\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u8bb2\u900f\uff0c\u9644\u9010\u623f\u95f4\u6838\u7b97\u8868\u3001\u4e24\u5957\u4e3b\u673a\u5bf9\u7167\u4e0e\u771f\u5b9e\u6848\u4f8b\u3002\u7cbe\u88c5\u623f\u62a2\u5728\u88c5\u4fee\u8fdb\u573a\u524d\u505a\u9690\u853d\u5de5\u7a0b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=14114","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-14T06:34:41+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=14114","url":"https:\/\/longmai-nt.com\/?page_id=14114","name":"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-10-07T07:09:22+00:00","dateModified":"2026-10-14T06:34:41+00:00","description":"\u6210\u90fd\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u9009\u578b\u516c\u5f00\u7248\uff1a\u4e0d\u505a\u5730\u6696\u3001\u51ac\u5929\u9760\u7a7a\u8c03\u91c7\u6696\uff0c\u5236\u51b7\u91c7\u6696\u5206\u5f00\u6838\u7b97\u3002\u70df\u56f1\u6548\u5e94\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u8bb2\u900f\uff0c\u9644\u9010\u623f\u95f4\u6838\u7b97\u8868\u3001\u4e24\u5957\u4e3b\u673a\u5bf9\u7167\u4e0e\u771f\u5b9e\u6848\u4f8b\u3002\u7cbe\u88c5\u623f\u62a2\u5728\u88c5\u4fee\u8fdb\u573a\u524d\u505a\u9690\u853d\u5de5\u7a0b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=14114#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=14114"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=14114#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14114"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14114\/revisions"}],"predecessor-version":[{"id":14927,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14114\/revisions\/14927"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}