{"id":14587,"date":"2026-10-11T17:19:28","date_gmt":"2026-10-11T09:19:28","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=14587"},"modified":"2026-10-11T19:26:43","modified_gmt":"2026-10-11T11:26:43","slug":"%e6%88%90%e9%83%bd%e5%a3%81%e6%8c%82%e7%82%89%e7%83%ad%e6%b0%b4%e5%bf%bd%e5%86%b7%e5%bf%bd%e7%83%ad%ef%bc%9a5-%e4%b8%aa%e5%8e%9f%e5%9b%a0%e4%b8%8e%e5%88%a4%e6%96%ad%ef%bd%9c%e9%be%99%e8%84%89-8","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=14587","title":{"rendered":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55"},"content":{"rendered":"\n<p><strong>\u6d17\u6fa1\u6c34\u4e00\u4f1a\u513f\u70eb\u4e00\u4f1a\u513f\u51c9<\/strong>\u2014\u2014\u8fd9\u662f\u6210\u90fd\u7528\u6237\u95ee\u5f97\u6700\u591a\u7684\u4e00\u7c7b\u3002\u5728\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u7684\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\"\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\"\u51fa\u73b0 <strong>\u7ea6 490 \u6b21<\/strong>\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002<\/p>\n<p>\u8fd9\u7c7b\u95ee\u9898\u7684\u539f\u56e0\u4e0d\u6b62\u4e00\u4e2a\uff0c\u6309\u6211\u4eec\u7684\u8bb0\u5f55\uff0c\u5e38\u89c1\u7684\u6709 <strong>5 \u7c7b<\/strong>\u3002\u4e0b\u9762\u4ece\"\u73b0\u573a\u6700\u5e38\u89c1\"\u5230\"\u673a\u578b\u5c42\u9762\"\u6392\u5f00\uff0c\u4e00\u5c42\u5c42\u8bb2\u3002<\/p>\n\n<h2>\u4e00\u30015 \u4e2a\u5e38\u89c1\u539f\u56e0\uff08\u6309\u73b0\u573a\u51fa\u73b0\u9891\u7387\uff09<\/h2>\n<table>\n<thead><tr><th>#<\/th><th>\u539f\u56e0<\/th><th>\u5178\u578b\u8868\u73b0<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>1<\/td><td><strong>\u6c34\u6c14\u52a8\u6001\u5931\u8861<\/strong>\uff08\u9891\u7e41\u5f00\u5173\u9f99\u5934\u3001\u6c34\u538b\u6ce2\u52a8\u3001\u6d41\u91cf\u4f4e\u4e8e\u70b9\u706b\u95e8\u69db\uff09<\/td><td>\u522b\u5904\u4e00\u5f00\u6c34\uff0c\u6d17\u6fa1\u6c34\u6e29\u5c31\u53d8\uff1b\u6c34\u6d41\u91cf\u5c0f\u7684\u65f6\u5019\u53cd\u590d\u70b9\u706b\u7184\u706b<\/td><\/tr>\n<tr><td>2<\/td><td><strong>\u4e24\u7528\u7089\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d<\/strong><\/td><td>\u590f\u5929\u6c34\u504f\u70eb\uff0c\u51ac\u5929\u6c34\u504f\u51c9<\/td><\/tr>\n<tr><td>3<\/td><td><strong>\u6c34\u6d41\u4f20\u611f\u5668\u6545\u969c<\/strong><\/td><td>\u4fe1\u53f7\u65f6\u65ad\u65f6\u7eed\uff0c\u4e3b\u677f\u53cd\u590d\u8c03\u706b\u529b\uff0c\u6c34\u6e29\u8df3<\/td><\/tr>\n<tr><td>4<\/td><td><strong>\u6052\u6e29\u82b1\u6d12 \/ \u6df7\u6c34\u9600\u8bef\u8c03<\/strong><\/td><td>\u51b7\u70ed\u6c34\u538b\u5dee\u5931\u8861\uff0c\u6d41\u91cf\u4f4e\u4e8e\u9505\u7089\u70b9\u706b\u95e8\u69db\u5c31\u7184\u706b<\/td><\/tr>\n<tr><td>5<\/td><td><strong>\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d \/ \u53d8\u9891\u63a7\u5236<\/strong><\/td><td>\u9760\u6bd4\u4f8b\u9600\u6ede\u540e\u8c03\u8282\uff0c\u6ce2\u52a8\u5927\uff08\u673a\u578b\u5c42\u9762\u5dee\u5f02\uff09<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u524d\u4e09\u7c7b\u5728\u73b0\u573a\u66f4\u5e38\u89c1\uff1b\u540e\u4e24\u7c7b\u662f\"\u70e7\u5f97\u7a33\u4e0d\u7a33\"\u7684\u6839\u672c\u3002\u4e0b\u9762\u91cd\u70b9\u8bb2 2 \u548c 5\uff0c\u56e0\u4e3a\u5b83\u4eec\u51b3\u5b9a\u4e86\u4f60\u5f53\u521d\u9009\u578b\u65f6\u5c31\u57cb\u4e0b\u7684\u540e\u679c\u3002<\/p>\n\n<h2>\u4e8c\u3001\u590f\u5b63\u8fc7\u70eb\u3001\u51ac\u5b63\u4e0d\u591f\uff1a\u4e24\u7528\u7089\u7684\u529f\u7387\u8d26<\/h2>\n<p>\u5148\u770b\u4e00\u4e2a\u516c\u5f0f\uff0c\u5b83\u628a\"\u591f\u4e0d\u591f\u70ed\"\u7b97\u5f97\u660e\u660e\u767d\u767d\uff1a<\/p>\n<blockquote><p><strong>\u51fa\u6c34\u91cf\uff08L\/min\uff09= 0.86 \u00d7 \u529f\u7387(kW) \u00d7 1000 \u00d7 \u70ed\u6548\u7387 \u00f7 \u6e29\u5dee(\u2103) \u00f7 60<\/strong><\/p><\/blockquote>\n<p>\u6309 80% \u70ed\u6548\u7387\u3001\u51ac\u5b63\u6e29\u5347 40\u2103 \u8ba1\u7b97\uff1a<\/p>\n<table>\n<thead><tr><th>\u9505\u7089\u529f\u7387<\/th><th>\u51ac\u5b63\u51fa\u6c34\u91cf<\/th><th>\u9002\u7528<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>18kW<\/td><td>\u7ea6 5.2L\/min<\/td><td>\u5355\u70b9\u6d17\u624b\u76c6<\/td><\/tr>\n<tr><td><strong>24kW<\/strong><\/td><td><strong>\u7ea6 6.9L\/min<\/strong><\/td><td><strong>\u52c9\u5f3a\u6ee1\u8db3\u666e\u901a\u82b1\u6d12<\/strong><\/td><\/tr>\n<tr><td>28kW<\/td><td>\u7ea6 8.0L\/min<\/td><td>\u666e\u901a\u82b1\u6d12<\/td><\/tr>\n<tr><td>32kW<\/td><td>\u7ea6 9.2L\/min<\/td><td>\u5927\u82b1\u6d12<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u666e\u901a\u82b1\u6d12\u9700\u8981 8L\/min \u4ee5\u4e0a<\/strong>\u2014\u2014\u6240\u4ee5 24kW \u4e24\u7528\u7089\u5728\u51ac\u5929\uff0c\u70ed\u6c34\u80fd\u529b\u662f\"\u52c9\u5f3a\"\u7684\u3002\u8fd9\u4e0d\u662f\u6545\u969c\uff0c\u662f\u529f\u7387\u672c\u8eab\u51b3\u5b9a\u7684\u3002<\/p>\n<p>\u53cd\u8fc7\u6765\u770b\u590f\u5929\uff1a\u666e\u901a\u4e24\u7528\u7089<strong>\u6700\u5c0f\u529f\u7387 8~10kW<\/strong>\uff0c\u4e0b\u4e0d\u6765\u3002\u590f\u5929\u8fdb\u6c34\u6e29\u5ea6\u9ad8\u3001\u9700\u8981\u7684\u70ed\u91cf\u5c11\uff0c\u4e00\u70b9\u706b\u5c31\u8d85\u6e29\u2014\u2014\u6709\u4e9b\u673a\u5668\u76f4\u63a5\u62a5 E1 \/ E4 \u8d85\u6e29\u3002<\/p>\n<p><strong>\u4e00\u53e5\u8bdd\uff1a\u51ac\u5929\u70e7\u4e0d\u591f\uff0c\u590f\u5929\u964d\u4e0d\u4e0b\u6765\u3002<\/strong><\/p>\n\n<h2>\u4e09\u3001\u4e3a\u4ec0\u4e48\"\u6052\u6e29\u4f3a\u670d\"\u662f\u5173\u952e<\/h2>\n<p>\u771f\u6b63\u8ba9\u6c34\u6e29\u7a33\u7684\uff0c\u662f\u8fd9\u4e09\u6837\u914d\u5408\uff1a<\/p>\n<table>\n<thead><tr><th>\u90e8\u4ef6<\/th><th>\u4f5c\u7528<\/th><th>\u666e\u901a\u4e24\u7528\u7089<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><strong>\u5206\u6bb5\u71c3\u70e7<\/strong><\/td><td>\u5c0f\u706b\u5c0f\u6c34\u91cf\u65f6\u53ea\u8ba9\u90e8\u5206\u706b\u6392\u5de5\u4f5c\uff0c\u89e3\u51b3\u590f\u5b63\u8fc7\u70eb<\/td><td>\u591a\u6570\u6ca1\u6709<\/td><\/tr>\n<tr><td><strong>\u6c34\u91cf\u4f3a\u670d\u5668<\/strong><\/td><td>\u6309\u8fdb\u6c34\u548c\u8bbe\u5b9a\u6e29\u5ea6\u81ea\u52a8\u8c03\u6c34\u6d41\u91cf\uff0c\u6052\u6e29\u51fa\u6c34\u7684\u57fa\u7840<\/td><td>\u591a\u6570\u6ca1\u6709<\/td><\/tr>\n<tr><td><strong>\u71c3\u6c14\u6bd4\u4f8b\u9600<\/strong><\/td><td>\u6309\u6c34\u6d41\u91cf\u7cbe\u786e\u8c03\u71c3\u6c14\u91cf<\/td><td>\u6709\uff0c\u4f46\u7f3a\u5c11\u524d\u7f6e\u7684\u6c34\u91cf\u8c03\u8282<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u518d\u5f80\u6df1\u4e00\u5c42\uff0c\u662f<strong>\u5b9a\u9891\u8fd8\u662f\u53d8\u9891<\/strong>\uff1a\u666e\u901a\u7089\u662f\u5b9a\u9891\uff0c\u9700\u8981\u6052\u5b9a\u6216\u6700\u5c0f\u6d41\u91cf\uff0c\u4e0d\u9002\u5408\u76f4\u63a5\u505a\u53d8\u6d41\u91cf\uff1b\u51b7\u51dd\u7089\u5168\u53d8\u9891\uff0c\u80fd\u6309\u9700\u8c03\u8282\u3002\u8fd9\u5c31\u662f\u4e3a\u4ec0\u4e48\u6362\u4e86\u6052\u6e29\u82b1\u6d12\u540e\uff0c\u666e\u901a\u7089\u53cd\u800c\u53ef\u80fd\u51fa\u73b0\"\u8d85\u6e29\u62a5\u8b66\"\u2014\u2014\u8fdb\u9505\u7089\u7684\u51b7\u6c34\u53d8\u5c11\u4e86\uff0c\u800c\u5b83\u6700\u5c0f\u529f\u7387\u5c31\u90a3\u4e48\u5927\uff0c\u6c34\u6e29\u8fc5\u901f\u51b2\u4e0a\u53bb\u3002<\/p>\n\n<h2>\u56db\u30018 \u5e74\u8bb0\u5f55\uff1a\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u6211\u4eec\u4e0a\u95e8\u7ea6 490 \u6b21<\/h2>\n<table>\n<thead><tr><th>\u8bb0\u5f55\u9879<\/th><th>\u6570\u503c<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u8bb0\u5f55<\/td><td>\u7ea6 490 \u6b21<\/td><td>\u4e0a\u95e8\u670d\u52a1\u8bb0\u5f55\u91cc\u5c45\u6545\u969c\u73b0\u8c61\u7b2c\u4e00<\/td><\/tr>\n<tr><td>\u5176\u4e2d\u9505\u7089\u7c7b\u4e0d\u70ed<\/td><td>135 \u6b21<\/td><td>\u9505\u7089\u7c7b 3,525 \u6761\u5de5\u5355\u4e2d\uff0c\u4e0d\u70ed\u5360\u7ea6 3.8%<\/td><\/tr>\n<tr><td>\u5173\u8054\u73b0\u8c61<\/td><td>\u9891\u7e41\u542f\u505c 13 \u6b21\u3001\u7ed3\u57a2 3 \u6b21<\/td><td>\u4e0e\"\u6700\u5c0f\u529f\u7387\u9ad8\u3001\u7cfb\u7edf\u7ed3\u57a2\"\u76f8\u5173<\/td><\/tr>\n<tr><td>\u8bbe\u5907\u5206\u5e03<\/td><td>\u9505\u7089 \/ \u58c1\u6302\u7089 3,525 \u6b21\uff0841%\uff09<\/td><td>\u91c7\u6696\u7cfb\u7edf\u6545\u969c\u5360\u6bd4\u6700\u9ad8\uff0c\u4e0e\u884c\u4e1a\u89c4\u5f8b\u4e00\u81f4<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u8fd9\u4e9b\u6570\u5b57\u8bf4\u660e\u4e00\u4ef6\u4e8b\uff1a\u8fd9\u7c7b\u95ee\u9898\u6211\u4eec<strong>\u89c1\u5f97\u591a\u3001\u4fee\u5f97\u5feb<\/strong>\uff0c\u6210\u90fd\u5404\u5c0f\u533a\u7684\u673a\u578b\u6211\u4eec\u57fa\u672c\u90fd\u78b0\u8fc7\u3002<\/p>\n\n<h2>\u4e94\u3001\u4e0a\u95e8\u600e\u4e48\u6536\u8d39\uff08\u660e\u7801\u6807\u4ef7\uff09<\/h2>\n<table>\n<thead><tr><th>\u9879\u76ee<\/th><th>\u975e\u4f1a\u5458\u4ef7<\/th><th>\u4f1a\u5458\u4ef7\uff08199 \u5143\/\u5e74\uff09<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e0a\u95e8\u670d\u52a1\u8d39\uff08\u4e09\u73af\u5185\uff09<\/td><td>100 \u5143\/\u6b21<\/td><td>90 \u5143\/\u6b21<\/td><\/tr>\n<tr><td>\u4e0a\u95e8\u670d\u52a1\u8d39\uff08\u4e09\u73af ~ \u4e00\u7ed5\uff09<\/td><td>150 \u5143\/\u6b21<\/td><td>90 \u5143\/\u6b21<\/td><\/tr>\n<tr><td>\u9505\u7089\u6e05\u6d17<\/td><td>360 \u5143\/\u53f0<\/td><td>180 \u5143\/\u53f0<\/td><\/tr>\n<tr><td>\u66f4\u6362\u4e09\u901a\u9600\u7535\u673a<\/td><td>160 \u5143\/\u4e2a<\/td><td>90 \u5143\/\u4e2a<\/td><\/tr>\n<tr><td>\u66f4\u6362\u6e29\u5ea6\u4f20\u611f\u5668<\/td><td>140 \u5143\/\u4e2a<\/td><td>60 \u5143\/\u4e2a<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u89c4\u77e9\uff1a<strong>\u5148\u62a5\u4ef7\u540e\u5f00\u5de5\uff0c\u4e2d\u9014\u4e0d\u52a0\u4ef7<\/strong>\uff1b\u6362\u914d\u4ef6\u7528\u539f\u5382\u4ef6\uff0c\u578b\u53f7\u548c\u4ef7\u683c\u5199\u5728\u62a5\u4ef7\u5355\u4e0a\uff1b<strong>\u540c\u4e00\u95ee\u9898 6 \u4e2a\u6708\u5185\u514d\u8d39\u590d\u67e5<\/strong>\u3002\u4e0d\u9650\u54c1\u724c\u3001\u4e0d\u9650\u662f\u5426\u5728\u4fdd\u3002<\/p>\n\n<h2>\u516d\u3001\u5e38\u89c1\u95ee\u9898<\/h2>\n<h3>\u6d17\u6fa1\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff0c\u6700\u5e38\u89c1\u662f\u4ec0\u4e48\u539f\u56e0\uff1f<\/h3>\n<p>\u5e38\u89c1\u7684\u662f\"\u6c34\u6c14\u8054\u52a8\u5931\u8861\"\uff1a\u9891\u7e41\u5f00\u5173\u9f99\u5934\u3001\u6c34\u538b\u6ce2\u52a8\uff0c\u6216\u7528\u6c34\u6d41\u91cf\u4f4e\u4e8e\u9505\u7089\u70b9\u706b\u95e8\u69db\uff0c\u5bfc\u81f4\u9505\u7089\u53cd\u590d\u70b9\u706b\u3001\u7184\u706b\u3002\u5176\u6b21\u662f\u4e24\u7528\u7089\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3002<\/p>\n<h3>\u4e3a\u4ec0\u4e48\u590f\u5929\u6c34\u5f88\u70eb\uff0c\u51ac\u5929\u53c8\u4e0d\u591f\u70ed\uff1f<\/h3>\n<p>\u8fd9\u662f\u4e24\u7528\u7089\u7684\u529f\u7387\u7279\u6027\u3002\u666e\u901a\u4e24\u7528\u7089\u6700\u5c0f\u529f\u7387 8~10kW\uff0c\u590f\u5929\u8fdb\u6c34\u6e29\u5ea6\u9ad8\u3001\u9700\u6c42\u5c0f\uff0c\u4e00\u70b9\u706b\u5c31\u5bb9\u6613\u8d85\u6e29\uff1b\u51ac\u5929\u8fdb\u6c34\u51b7\u3001\u6e29\u5347\u5927\uff0c\u52a0\u70ed\u80fd\u529b\u53c8\u4e0d\u591f\u3002\u6309\u51fa\u6c34\u91cf\u516c\u5f0f\uff0c24kW \u4e24\u7528\u7089\u51ac\u5b63\uff08\u6e29\u5347 40\u2103\uff09\u51fa\u6c34\u91cf\u7ea6 6.9L\/min\uff0c\u800c\u666e\u901a\u82b1\u6d12\u901a\u5e38\u9700\u8981 8L\/min \u4ee5\u4e0a\u3002<\/p>\n<h3>\u6362\u4e2a\u5927\u529f\u7387\u9505\u7089\u662f\u4e0d\u662f\u5c31\u4e0d\u5ffd\u51b7\u5ffd\u70ed\u4e86\uff1f<\/h3>\n<p>\u4e0d\u4e00\u5b9a\u3002\u529f\u7387\u5927\u89e3\u51b3\u7684\u662f\"\u51ac\u5929\u4e0d\u591f\u70ed\"\uff0c\u4f46\u590f\u5929\u66f4\u5bb9\u6613\u8fc7\u70eb\uff0c\u56e0\u4e3a\u6700\u5c0f\u529f\u7387\u4e5f\u66f4\u9ad8\u3002\u771f\u6b63\u8ba9\u6c34\u6e29\u7a33\u7684\u662f\u6052\u6e29\u4f3a\u670d\uff08\u6c34\u91cf\u4f3a\u670d\u5668\uff09\u548c\u5206\u6bb5\u71c3\u70e7\uff0c\u4e0d\u662f\u5355\u7eaf\u52a0\u5927\u529f\u7387\u3002\u4e5f\u4e0d\u5efa\u8bae\u4e3a\u70ed\u6c34\u9700\u6c42\u628a\u9505\u7089\u653e\u5927\u5230\u70ed\u8d1f\u8377 1.5 \u500d\u4ee5\u4e0a\u3002<\/p>\n<h3>\u4ec0\u4e48\u662f\u6052\u6e29\u4f3a\u670d\uff08\u6c34\u91cf\u4f3a\u670d\u5668\uff09\uff1f\u6211\u7684\u7089\u5b50\u6709\u6ca1\u6709\uff1f<\/h3>\n<p>\u6c34\u91cf\u4f3a\u670d\u5668\u4f1a\u6309\u8fdb\u6c34\u6e29\u5ea6\u548c\u8bbe\u5b9a\u6e29\u5ea6\u81ea\u52a8\u8c03\u8282\u6c34\u6d41\u91cf\uff0c\u662f\u6052\u6e29\u51fa\u6c34\u7684\u57fa\u7840\uff1b\u914d\u5408\u5206\u6bb5\u71c3\u70e7\uff0c\u624d\u80fd\u5728\u5c0f\u706b\u5c0f\u6c34\u91cf\u65f6\u4e0d\u8d85\u6e29\u3002\u4e2d\u9ad8\u7aef\u51b7\u51dd\u7089\u591a\u5e26\u4f3a\u670d\uff0c\u666e\u901a\u4e24\u7528\u7089\u591a\u6570\u6ca1\u6709\u2014\u2014\u8fd9\u662f\u673a\u578b\u5c42\u9762\u7684\u5dee\u5f02\u3002<\/p>\n<h3>\u5ffd\u51b7\u5ffd\u70ed\u4e0a\u95e8\u600e\u4e48\u6536\u8d39\uff1f<\/h3>\n<p>\u4e0a\u95e8\u8d39\u6309\u8ddd\u79bb\uff0c\u4e09\u73af\u5185 100 \u5143\/\u6b21\u3001\u4e09\u73af\u5230\u4e00\u7ed5 150 \u5143\/\u6b21\uff1b\u9505\u7089\u6e05\u6d17 360 \u5143\/\u53f0\uff1b\u6362\u4e09\u901a\u9600\u7535\u673a 160 \u5143\/\u4e2a\uff08\u53e6\u8ba1\u5de5\u65f6\uff09\u3002\u5148\u62a5\u4ef7\u540e\u5f00\u5de5\uff0c\u540c\u4e00\u95ee\u9898 6 \u4e2a\u6708\u5185\u514d\u8d39\u590d\u67e5\u3002<\/p>\n<h3>\u600e\u4e48\u624d\u80fd\u5f7b\u5e95\u89e3\u51b3\uff1f<\/h3>\n<p>\u6839\u5b50\u4e0a\u662f\"\u91c7\u6696\u4e0e\u70ed\u6c34\u5206\u5f00\"\uff1a\u91c7\u6696\u7528\u9505\u7089\u3001\u70ed\u6c34\u7528\u72ec\u7acb\u70ed\u6c34\u5668\uff08\u5982 24kW \u4e24\u7528\u7089\u914d 13L \u72ec\u7acb\u70ed\u6c34\u5668\uff09\uff0c\u6216\u76f4\u63a5\u4e0a\u5e26\u6c34\u91cf\u4f3a\u670d\u548c\u5206\u6bb5\u71c3\u70e7\u7684\u673a\u578b\u3002\u6211\u4eec\u4e0a\u95e8\u65f6\u4f1a\u5148\u68c0\u6d4b\u3001\u518d\u7ed9\u65b9\u6848\u3002<\/p>\n\n<h2>\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p>\u6210\u90fd\u672c\u5730\u6696\u901a\u670d\u52a1\u5546\uff0c2004 \u5e74\u8d77\u505a\u8fd9\u884c\uff0c\u4e13\u6ce8\u535a\u4e16\u3001\u5a01\u80fd\u3001\u83f2\u65af\u66fc\u3001\u6797\u5185\u3001\u745e\u7f8e\u7b49\u54c1\u724c\u58c1\u6302\u7089\u7684\u4e0a\u95e8\u7ef4\u4fee\u4fdd\u517b\u3002\u5357\u3001\u5317\u5bcc\u68ee\u4e24\u4e2a\u95e8\u5e97\u5e38\u5e74\u6709\u4eba\u3002<\/p>\n<ul>\n<li><strong>\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u4e13\u7bc7<\/strong>\uff1a\u672c\u7bc7<\/li>\n<li><strong>\u58c1\u6302\u7089\u7ef4\u4fee\u4fdd\u517b\u603b\u76ee\u5f55\uff08\u542b\u5404\u54c1\u724c\u4ee3\u7801\u5bf9\u7167\uff09<\/strong>\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=13109\">\u6210\u90fd\u58c1\u6302\u7089\u7ef4\u4fee\u4fdd\u517b\uff5c\u4e0d\u70b9\u706b\u3001\u62a5\u9519\u4ee3\u7801\u3001\u6f0f\u6c34<\/a><\/li>\n<li><strong>\u76f8\u5173\u4e0a\u95e8\u5b9e\u5f55<\/strong>\uff1a\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13587\">\u535a\u4e16\u58c1\u6302\u7089\u6c34\u6e29\u5ffd\u51b7\u5ffd\u70ed\uff08\u4e09\u901a\u9600\u5361\u6ede\u6e05\u7406\uff09<\/a>\u3001\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=13184\">\u66fc\u745e\u5fb7\u9505\u7089\u70ed\u6c34\u4e0d\u70ed\u4e0a\u95e8\u6392\u67e5<\/a>\u3001\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=10270\">\u9505\u7089\u6c34\u6e29\u4e0d\u7a33\u5b9a\u6392\u67e5<\/a>\n<\/li>\n<li><strong>\u5357\u5bcc\u68ee\u5e97<\/strong>\uff1a\u9ad8\u65b0\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45 A347B \/ A348\u3000\u7535\u8bdd <a href=\"tel:02886131795\">028-86131795<\/a>\u3000<a href=\"https:\/\/uri.amap.com\/marker?markers=104.0641,30.5856,A347B&callnative=1&src=longmai&coordinate=gaode\">\u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a<\/a><\/li>\n<li><strong>\u5317\u5bcc\u68ee\u5e97<\/strong>\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45 A5135\u3000\u7535\u8bdd <a href=\"tel:02865272586\">028-65272586<\/a>\u3000<a href=\"https:\/\/uri.amap.com\/marker?markers=104.1478,30.6919,A5135&callnative=1&src=longmai&coordinate=gaode\">\u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a<\/a><\/li>\n<li><strong>\u552e\u540e\u8054\u7cfb\u4eba<\/strong>\uff1a\u6768\u6676\u6676 <a href=\"tel:15680075476\">156-8007-5476<\/a><\/li>\n<\/ul>\n<p><em>\u672c\u6587\u6240\u5217\u8bb0\u5f55\u6765\u81ea\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u7684\u5b9e\u9645\u4e0a\u95e8\u670d\u52a1\u53f0\u8d26\uff0c\u4ec5\u4ee3\u8868\u6211\u4eec\u7684\u670d\u52a1\u7ecf\u9a8c\u4e0e\u5e38\u89c1\u6392\u67e5\u7ebf\u7d22\uff0c\u4e0d\u6784\u6210\u5bf9\u4efb\u4f55\u54c1\u724c\u4ea7\u54c1\u8d28\u91cf\u7684\u8bc4\u4ef7\uff1b\u5177\u4f53\u539f\u56e0\u4ee5\u73b0\u573a\u68c0\u6d4b\u4e3a\u51c6\u3002<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6d17\u6fa1\u6c34\u4e00\u4f1a\u513f\u70eb\u4e00\u4f1a\u513f\u51c9\u2014\u2014\u8fd9\u662f\u6210\u90fd\u7528\u6237\u95ee [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-14587","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u89e3\u51b3\uff1f\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u7c7b\u7ea6 490 \u6b21\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002\u5e38\u89c1 5 \u4e2a\u539f\u56e0\uff1a\u6c34\u6c14\u52a8\u6001\u5931\u8861\u3001\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u6d41\u4f20\u611f\u5668\u3001\u82b1\u6d12\u6df7\u6c34\u9600\u3001\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d\u3002\u6587\u4e2d\u7ed9\u51fa\u51fa\u6c34\u91cf\u516c\u5f0f\uff0824kW \u51ac\u5b63\u7ea6 6.9L\/min\uff09\u4e0e\u660e\u7801\u6807\u4ef7\u6536\u8d39\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=14587\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u89e3\u51b3\uff1f\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u7c7b\u7ea6 490 \u6b21\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002\u5e38\u89c1 5 \u4e2a\u539f\u56e0\uff1a\u6c34\u6c14\u52a8\u6001\u5931\u8861\u3001\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u6d41\u4f20\u611f\u5668\u3001\u82b1\u6d12\u6df7\u6c34\u9600\u3001\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d\u3002\u6587\u4e2d\u7ed9\u51fa\u51fa\u6c34\u91cf\u516c\u5f0f\uff0824kW \u51ac\u5b63\u7ea6 6.9L\/min\uff09\u4e0e\u660e\u7801\u6807\u4ef7\u6536\u8d39\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=14587\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-11T11:26:43+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14587\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14587\",\"name\":\"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-10-11T09:19:28+00:00\",\"dateModified\":\"2026-10-11T11:26:43+00:00\",\"description\":\"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u89e3\u51b3\uff1f\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\u4e0d\u70ed \\\/ \u6c34\u6e29\u4f4e\u7c7b\u7ea6 490 \u6b21\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002\u5e38\u89c1 5 \u4e2a\u539f\u56e0\uff1a\u6c34\u6c14\u52a8\u6001\u5931\u8861\u3001\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u6d41\u4f20\u611f\u5668\u3001\u82b1\u6d12\u6df7\u6c34\u9600\u3001\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d\u3002\u6587\u4e2d\u7ed9\u51fa\u51fa\u6c34\u91cf\u516c\u5f0f\uff0824kW \u51ac\u5b63\u7ea6 6.9L\\\/min\uff09\u4e0e\u660e\u7801\u6807\u4ef7\u6536\u8d39\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14587#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14587\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14587#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u89e3\u51b3\uff1f\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u7c7b\u7ea6 490 \u6b21\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002\u5e38\u89c1 5 \u4e2a\u539f\u56e0\uff1a\u6c34\u6c14\u52a8\u6001\u5931\u8861\u3001\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u6d41\u4f20\u611f\u5668\u3001\u82b1\u6d12\u6df7\u6c34\u9600\u3001\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d\u3002\u6587\u4e2d\u7ed9\u51fa\u51fa\u6c34\u91cf\u516c\u5f0f\uff0824kW \u51ac\u5b63\u7ea6 6.9L\/min\uff09\u4e0e\u660e\u7801\u6807\u4ef7\u6536\u8d39\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=14587","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u89e3\u51b3\uff1f\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u7c7b\u7ea6 490 \u6b21\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002\u5e38\u89c1 5 \u4e2a\u539f\u56e0\uff1a\u6c34\u6c14\u52a8\u6001\u5931\u8861\u3001\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u6d41\u4f20\u611f\u5668\u3001\u82b1\u6d12\u6df7\u6c34\u9600\u3001\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d\u3002\u6587\u4e2d\u7ed9\u51fa\u51fa\u6c34\u91cf\u516c\u5f0f\uff0824kW \u51ac\u5b63\u7ea6 6.9L\/min\uff09\u4e0e\u660e\u7801\u6807\u4ef7\u6536\u8d39\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=14587","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-11T11:26:43+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=14587","url":"https:\/\/longmai-nt.com\/?page_id=14587","name":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-10-11T09:19:28+00:00","dateModified":"2026-10-11T11:26:43+00:00","description":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u89e3\u51b3\uff1f\u9f99\u8109\u6696\u901a 2018 \u5e74\u81f3\u4eca\u4e0a\u95e8\u8bb0\u5f55\u91cc\uff0c\u4e0d\u70ed \/ \u6c34\u6e29\u4f4e\u7c7b\u7ea6 490 \u6b21\uff0c\u662f\u7b2c\u4e00\u9ad8\u9891\u3002\u5e38\u89c1 5 \u4e2a\u539f\u56e0\uff1a\u6c34\u6c14\u52a8\u6001\u5931\u8861\u3001\u590f\u51ac\u529f\u7387\u4e0d\u5339\u914d\u3001\u6c34\u6d41\u4f20\u611f\u5668\u3001\u82b1\u6d12\u6df7\u6c34\u9600\u3001\u673a\u578b\u7f3a\u6052\u6e29\u4f3a\u670d\u3002\u6587\u4e2d\u7ed9\u51fa\u51fa\u6c34\u91cf\u516c\u5f0f\uff0824kW \u51ac\u5b63\u7ea6 6.9L\/min\uff09\u4e0e\u660e\u7801\u6807\u4ef7\u6536\u8d39\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=14587#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=14587"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=14587#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u58c1\u6302\u7089\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1a5 \u4e2a\u539f\u56e0\u4e0e\u5224\u65ad\uff5c\u9f99\u8109 8 \u5e74\u8bb0\u5f55"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14587"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14587\/revisions"}],"predecessor-version":[{"id":14687,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14587\/revisions\/14687"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}