{"id":14764,"date":"2026-10-13T02:05:16","date_gmt":"2026-10-12T18:05:16","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=14764"},"modified":"2026-10-26T01:41:48","modified_gmt":"2026-10-25T17:41:48","slug":"%e6%88%90%e9%83%bd%e6%97%a5%e7%ab%8b%e6%b0%b4%e5%a2%85%e9%80%82%e6%b0%b4%e6%9c%ba%e4%ba%8c%e8%81%94%e4%be%9b%e4%bb%b7%e6%a0%bc%ef%bd%9cfx-vf-%e5%85%a8%e7%b3%bb%e5%88%97%e6%9c%ba%e5%9e%8b%e4%b8%8e","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=14764","title":{"rendered":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97"},"content":{"rendered":"\n<div class=\"lmss\">\n<div class=\"lmss-wrap\">\n\n<span class=\"lmss-badge\">\ud83d\udcd0 GEO \u4e94\u6b65\u6cd5 \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c<\/span>\n\n<h2 class=\"lmss-h1\">\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97\u53c2\u8003<\/h2>\n\n<div class=\"lmss-lead\">\n<p>\u6c34\u7cfb\u7edf\u7684\u62a5\u4ef7\u5dee\u5728\u54ea\uff1f\u516b\u6210\u4e0d\u5728\u8bbe\u5907\uff0c\u5728\u8bbe\u8ba1\uff1a\u4e3b\u673a\u9009\u591a\u5927\u3001\u672b\u7aef\u914d\u51e0\u7ec4\u3001\u7ba1\u5f84\u600e\u4e48\u8d70\u3001\u8981\u4e0d\u8981\u7f13\u51b2\u6c34\u7bb1\u3001\u63a7\u5236\u505a\u5230\u54ea\u4e00\u7ea7\u3002\u5148\u8bf4\u8bbe\u8ba1\u600e\u4e48\u51b3\u5b9a\u9020\u4ef7\uff0c\u518d\u770b\u4e0b\u9762\u7684\u4ef7\u683c\u8868\u3002<\/p>\n\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09\u662f\u65e5\u7acb\u6237\u5f0f\u6c34\u673a\u7684\u4e24\u6761\u4e3b\u529b\u4ea7\u54c1\u7ebf\u2014\u2014<strong>FX \u7cfb\u5217\uff08140\uff5e340 \u578b\uff09<\/strong>\u4e0e <strong>VF \u5168\u53d8\u9891\u7cfb\u5217\uff0880\uff5e500 \u578b\uff09<\/strong>\u3002\u672c\u9875\u628a\u4e24\u7cfb\u5217\u7684<strong>\u5168\u578b\u53f7\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u3001\u53c2\u8003\u96f6\u552e\u4ef7<\/strong>\u4e00\u6b21\u6027\u5217\u5168\uff0c\u518d\u7ed9\u51fa\u6210\u90fd\u672c\u5730\u300c\u7a7a\u8c03 + \u5730\u6696\u6574\u5957\u300d\u7684\u6210\u4ea4\u53c2\u8003\u533a\u95f4\uff08\u4e00\u62d6\u56db \/ \u4e94 \/ \u516d\uff09\uff0c\u5e76\u8bb2\u6e05\u6c34\u673a\u6bd4\u6c1f\u673a\u8d35\u5728\u54ea\u3001\u54ea\u4e9b\u94b1\u4e0d\u80fd\u7701\u3002<strong>\u6700\u7ec8\u4ef7\u683c\u4ee5\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u5177\u6b63\u5f0f\u65b9\u6848\u4e3a\u51c6\u3002<\/strong>\u6210\u90fd\u5168\u57df\u53ef\u9884\u7ea6\u514d\u8d39\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b\u3002\n<\/div>\n\n<div class=\"lm-fit\">\n<p class=\"lm-fit-t\">\u5148\u5bf9\u53f7\uff1a\u6c34\u5885\u9002\u4e8c\u8054\u4f9b\u9002\u4e0d\u9002\u5408\u60a8\u5bb6\uff1f<\/p>\n<p><strong>\u2705 \u9002\u5408\uff1a<\/strong>\u522b\u5885\u3001\u53e0\u62fc\u3001200\u33a1 \u4e0a\u4e0b\u7684\u5927\u5b85\uff1b\u957f\u671f\u81ea\u4f4f\u3001\u51ac\u5b63\u5730\u6696\u8981\u7a33\u5b9a\u53ef\u9760\uff1b\u559c\u6b22\u6c34\u673a\u51fa\u98ce\u67d4\u548c\uff087\uff5e25\u2103\u3001\u8212\u9002\u533a 15\uff5e20\u2103\uff09\u3001\u4e00\u5957\u4e3b\u673a\u540c\u65f6\u89e3\u51b3\u7a7a\u8c03\u4e0e\u5730\u6696\u3002<\/p>\n<p><strong>\u274c \u5148\u7b49\u7b49\uff0c\u5982\u679c\u60a8\u662f\u8fd9\u4e9b\u60c5\u51b5\uff1a<\/strong>100\u33a1 \u4e0a\u4e0b\u7684\u5e38\u89c4\u6237\u578b\u3001\u9884\u7b97\u4f18\u5148\u2014\u2014<a href=\"https:\/\/longmai-nt.com\/?page_id=1957\">\u667a\u4eab\u5929\u6c1f\u5730\u6c34<\/a>\u6216<a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u8212\u4eab\u6c1f\u7cfb\u7edf<\/a>\u66f4\u52a1\u5b9e\uff1b\u53ea\u88c5\u5236\u51b7\u3001\u4e0d\u88c5\u91c7\u6696\u2014\u2014\u8212\u4eab\u6c1f\u673a\u5c31\u591f\u3002<\/p>\n<p><strong>\ud83e\udded \u62ff\u4e0d\u51c6\uff1f<\/strong>\u5148\u82b1 3 \u5206\u949f\u505a\u4e00\u904d<a href=\"https:\/\/longmai-nt.com\/?page_id=15567\">\u9009\u578b\u524d\u7684 3 \u4e2a\u81ea\u6211\u63d0\u95ee<\/a>\uff0c\u518d\u56de\u6765\u770b\u6863\u4f4d\uff1b\u91c7\u6696\u8def\u7ebf\u7684\u5206\u6cd5\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=15178\">\u6210\u90fd\u91c7\u6696\u600e\u4e48\u9009<\/a>\u3002<\/p>\n<\/div>\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\u2460<\/span>\u5ba2\u6237\u6210\u529f\u76ee\u6807\uff1a\u628a\u8fd9\u9875\u5f53\u6210\"\u6bd4\u4ef7\u5e95\u7a3f\"\u7528<\/h2>\n<p class=\"lmss-desc\">\u6c34\u673a\u4e8c\u8054\u4f9b\u662f\u6696\u901a\u91cc\u8f83\u5bb9\u6613\u88ab\"\u6a21\u7cca\u62a5\u4ef7\"\u7684\u54c1\u7c7b\u2014\u2014\u540c\u4e00\u4e2a\u6237\u578b\uff0c\u6709\u4eba\u62a5 6 \u4e07\u3001\u6709\u4eba\u62a5 9 \u4e07\uff0c\u5dee\u7684\u5f80\u5f80\u4e0d\u662f\u54c1\u724c\uff0c\u800c\u662f\u578b\u53f7\u6863\u4f4d\u3001\u98ce\u673a\u76d8\u7ba1\u6570\u91cf\u4e0e\u5b89\u88c5\u6807\u51c6\u3002\u672c\u9875\u7684\u76ee\u6807\u662f\u8ba9\u60a8\u5728\u7b7e\u5408\u540c\u524d\uff0c\u624b\u91cc\u5c31\u6709\u4e00\u5f20\u80fd\u9010\u9879\u5bf9\u7167\u7684\u6e05\u5355\u3002<\/p>\n\n<div class=\"lmss-card\">\n<div class=\"lmss-card-h\"><span class=\"lmss-ic\">\ud83d\udccb<\/span>\u5ba2\u6237\u4fe1\u606f\u5361\uff08\u9500\u552e\u73b0\u573a\u586b\u5199 \u00b7 \u53ef\u6253\u5370\uff09<\/div>\n<div class=\"lmss-kv\">\n<dt>\u5ba2\u6237 \/ \u697c\u76d8<\/dt><dd>\u3000<\/dd>\n<dt>\u623f\u5c4b\u7c7b\u578b<\/dt><dd>\u3000\u5e73\u5c42 \/ \u8dc3\u5c42 \/ \u522b\u5885\u3000\u00b7\u3000\u6bdb\u576f \/ \u7cbe\u88c5<\/dd>\n<dt>\u5957\u5185\u9762\u79ef<\/dt><dd>\u3000\u33a1\u3000\u00b7\u3000\u9700\u91c7\u6696\u9762\u79ef\u3000\u33a1<\/dd>\n<dt>\u5916\u673a\u4f4d\u6761\u4ef6<\/dt><dd>\u3000\u98d8\u7a97\u4e0b \/ \u8bbe\u5907\u5e73\u53f0 \/ \u9876\u697c\u5c4b\u9762\u3000\u00b7\u3000\u53ef\u88c5\u5355\u98ce\u6247 \/ \u53cc\u98ce\u6247<\/dd>\n<dt>\u7535\u6e90\u6761\u4ef6<\/dt><dd>\u3000220V \u5355\u76f8 \/ 380V \u4e09\u76f8\uff08\u51b3\u5b9a\u9009 FX \u5355\u76f8\u8fd8\u662f\u4e09\u76f8\u6bb5\uff09<\/dd>\n<dt>\u5173\u6ce8\u91cd\u70b9<\/dt><dd>\u25a1 \u51fa\u98ce\u67d4\u548c\u3000\u25a1 \u5730\u6696\u7701\u8d39\u3000\u25a1 \u540e\u671f\u53ef\u5347\u7ea7\u4e94\u6052\u3000\u25a1 \u9884\u7b97\u63a7\u5236<\/dd>\n<dt>\u521d\u5224\u4e3b\u673a\u6863\u4f4d<\/dt><dd>\u3000<\/dd>\n<\/div>\n<\/div>\n\n<div class=\"lmss-grid4\" style=\"margin-top:16px\">\n<div class=\"lmss-pain\"><b>\ud83d\udcb0 \u6015\u62a5\u4ef7\u865a\u9ad8<\/b><span>\u540c\u53eb\"\u6c34\u5885\u9002\"\uff0cFX \u548c VF \u5dee\u4ef7\u53ef\u89c2\uff0c\u578b\u53f7\u4e0d\u5199\u660e\u5c31\u65e0\u6cd5\u6bd4\u4ef7<\/span><\/div>\n<div class=\"lmss-pain\"><b>\ud83d\udd0d \u578b\u53f7\u770b\u4e0d\u61c2<\/b><span>RAS-160FPUEN2Q\/M \u8fd9\u79cd\u7f16\u53f7\u5230\u5e95\u5bf9\u5e94\u51e0\u5339\u3001\u80fd\u5e26\u591a\u5927\u623f\u5b50<\/span><\/div>\n<div class=\"lmss-pain\"><b>\ud83c\udf00 FX \u8fd8\u662f VF<\/b><span>\u4e24\u6761\u7ebf\u90fd\u53eb\u6c34\u5885\u9002\uff0c\u4e00\u4e2a\u504f\u5b9a\u5236\u4e00\u4e2a\u504f\u6210\u719f\uff0c\u600e\u4e48\u9009<\/span><\/div>\n<div class=\"lmss-pain\"><b>\ud83d\udcc9 \u540e\u671f\u8d39\u7528<\/b><span>\u6c34\u673a\u6bd4\u6c1f\u673a\u8d35\uff0c\u591a\u82b1\u7684\u94b1\u591a\u4e45\u80fd\u4ece\u8fd0\u884c\u8d39\u91cc\u7701\u56de\u6765<\/span><\/div>\n<\/div>\n\n<div class=\"lmss-callout\">\n<b>\u672c\u9875\u627f\u8bfa\u7684\u4e09\u4ef6\u4e8b\uff1a<\/b>\u2460 \u578b\u53f7\u9010\u5b57\u6bcd\u5199\u5168\uff0c\u4e0d\u5199\"\u5dee\u4e0d\u591a 160 \u7684\"\uff1b\u2461 \u4ef7\u683c\u53ea\u51fa\u6210\u90fd\u771f\u5b9e\u6210\u4ea4\u53e3\u5f84\uff0c\u4e0d\u7f16\u9020\u672a\u4e0a\u5e02\u578b\u53f7\u4ef7\uff1b\u2462 \u6bcf\u4e00\u6863\u4ef7\u683c\u90fd\u5199\u660e\"\u542b\u4ec0\u4e48\u3001\u4e0d\u542b\u4ec0\u4e48\"\uff0c\u907f\u514d\u540e\u671f\u589e\u9879\u626f\u76ae\u3002\n<\/div>\n\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\u2461<\/span>\u9700\u6c42\u75db\u70b9\u5206\u6790\uff1a\u6c34\u673a\u4e24\u8054\u4f9b\u7684\u94b1\u82b1\u5728\u54ea<\/h2>\n<p class=\"lmss-desc\">\u5f88\u591a\u4eba\u7b2c\u4e00\u6b21\u770b\u6c34\u673a\u62a5\u4ef7\uff0c\u4f1a\u89c9\u5f97\"\u4e0d\u5c31\u662f\u4e00\u53f0\u5916\u673a\u52a0\u51e0\u53f0\u5185\u673a\u5417\"\u3002\u5176\u5b9e\u6c34\u673a\u7684\u6210\u672c\u7ed3\u6784\u4e0e\u6c1f\u673a\u5b8c\u5168\u4e0d\u540c\u2014\u2014\u5b83\u591a\u4e86\u4e00\u6574\u6761\u6c34\u8def\u7cfb\u7edf\u3002\u4e0b\u9762\u628a\u663e\u6027\u652f\u51fa\u548c\u9690\u6027\u652f\u51fa\u5206\u5f00\u770b\u3002<\/p>\n\n<h3 class=\"lmss-h3\">2.1 \u663e\u6027\u652f\u51fa\uff08\u62a5\u4ef7\u5355\u4e0a\u770b\u5f97\u89c1\u7684\uff09<\/h3>\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u652f\u51fa\u9879<\/th><th>\u8bf4\u660e<\/th><th>\u5728\u603b\u4ef7\u4e2d\u7684\u91cf\u7ea7<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u6c34\u5885\u9002\u5916\u673a<\/td><td>FX \/ VF \u4e3b\u673a\u672c\u4f53\uff0c\u6309\u5339\u6570\u4e0e\u7535\u6e90\u5f62\u5f0f\u5b9a\u4ef7<\/td><td class=\"lmss-price\">\u5360\u6bd4\u5927<\/td><\/tr>\n<tr><td>\u98ce\u673a\u76d8\u7ba1<\/td><td>\u96f6\u8d8a\u7b49\u7cfb\u5217\uff0c\u6309\u623f\u95f4\u8d1f\u8377\u9010\u95f4\u914d\u7f6e\uff0c\u6570\u91cf\u968f\u6237\u578b\u8d70<\/td><td class=\"lmss-price\">\u6309\u53f0\u6570\u7d2f\u52a0<\/td><\/tr>\n<tr><td>\u6c34\u7cfb\u7edf\u9009\u6750<\/td><td>\u4e3b\u7ba1 + \u652f\u7ba1 + \u98ce\u76d8\u9600\u95e8 + \u914d\u4ef6 + \u4fdd\u6e29\uff0c\u6309\"\u5143\/\u98ce\u76d8\"\u8ba1<\/td><td class=\"lmss-price\">\u6309\u98ce\u76d8\u6570\u8ba1<\/td><\/tr>\n<tr><td>\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5<\/td><td>\u542b\u6750\u6599\u4e0e\u4eba\u5de5\uff0c\u6309\u4e3b\u673a\u89c4\u683c\u4e0e\u5b89\u88c5\u65b9\u5f0f\u5206\u6863<\/td><td class=\"lmss-price\">\u6309\u5957\u8ba1<\/td><\/tr>\n<tr><td>\u5730\u6696\u90e8\u5206<\/td><td>\u76d8\u7ba1 + \u4fdd\u6e29 + \u56de\u586b\u627e\u5e73 + \u5206\u96c6\u6c34\u5668 + \u8054\u52a8\u63a7\u5236<\/td><td class=\"lmss-price\">\u6309\u91c7\u6696\u9762\u79ef\u8ba1<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3 class=\"lmss-h3\">2.2 \u9690\u6027\u652f\u51fa\uff08\u62a5\u4ef7\u5355\u4e0a\u5bb9\u6613\u88ab\"\u7701\u7565\"\u7684\uff09<\/h3>\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5bb9\u6613\u88ab\u7701\u7565\u7684\u9879<\/th><th>\u4e3a\u4ec0\u4e48\u91cd\u8981<\/th><th>\u4e0d\u95ee\u6e05\u7684\u540e\u679c<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5916\u673a\u7535\u6e90\u7ebf\u53ca\u642d\u5efa<\/td><td>\u6c34\u5885\u9002\u5916\u673a\u529f\u7387\u5927\uff0c220V \u4e0e 380V \u8d70\u7ebf\u8981\u6c42\u4e0d\u540c\uff1b\u5916\u673a\u540a\u88c5\u53e6\u8ba1<\/td><td>\u8fdb\u573a\u540e\u52a0\u94b1\uff0c\u6216\u88ab\u7b80\u5316\u65bd\u5de5<\/td><\/tr>\n<tr><td>\u4e3b\u673a\u6863\u4f4d\u662f\u5426\u591f<\/td><td>\u540c\u4e3a\u4e00\u62d6\u56db\uff0c\u5916\u673a\u53ef\u4e3a 140 \/ 160 \/ 180 \u7b49\u4e0d\u540c\u6863\u4f4d<\/td><td>\u5236\u51b7\u591f\u3001\u5730\u6696\u51ac\u5929\u5403\u7d27<\/td><\/tr>\n<tr><td>\u662f\u5426\u5e26\u7f13\u51b2\u6c34\u7bb1<\/td><td>\u53d6\u51b3\u7cfb\u7edf\u603b\u6c34\u91cf\u662f\u5426\u8fbe\u4e3b\u673a\u8981\u6c42\u7684\u6700\u5c0f\u6c34\u5bb9\u91cf<\/td><td>\u6c34\u6e29\u6ce2\u52a8\u3001\u4e3b\u673a\u9891\u7e41\u542f\u505c<\/td><\/tr>\n<tr><td>\u8054\u52a8\u63a7\u5236\u6df1\u5ea6<\/td><td>\u98ce\u76d8\u4e0e\u5730\u6696\u80fd\u5426\u8054\u52a8\u4e3b\u673a\u3001\u80fd\u5426\u8fdc\u7a0b\u63a7\u5236<\/td><td>\u51ac\u5929\u4e24\u5957\u7cfb\u7edf\u5404\u7ba1\u5404\u7684\uff0c\u8d39\u7535<\/td><\/tr>\n<tr><td>\u627e\u5e73\u662f\u5426\u542b\u56de\u586b<\/td><td>\u5730\u6696\u56de\u586b\u627e\u5e73\u5c5e\u571f\u5efa\u5de5\u5e8f\uff0c\u6709\u7684\u62a5\u4ef7\u5355\u4e0d\u542b<\/td><td>\u540e\u671f\u5355\u5217\u589e\u9879<\/td><\/tr>\n<tr><td>\u62c6\u9664\u4e0e\u6539\u9020<\/td><td>\u7cbe\u88c5\u623f\u540a\u9876\u62c6\u9664\u3001\u5730\u9762\u62ac\u9ad8\u53d7\u9650\u7b49<\/td><td>\u65bd\u5de5\u65b9\u6848\u4e0e\u9020\u4ef7\u53cc\u53d8<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"lmss-callout\">\n<b>\u8bca\u65ad\u7ed3\u8bba\uff1a<\/b>\u6c34\u673a\u4e24\u8054\u4f9b\u7684\u94b1\uff0c\u4e00\u534a\u5728\u8bbe\u5907\u3001\u4e00\u534a\u5728\"\u7cfb\u7edf\u548c\u65bd\u5de5\"\u3002\u6240\u4ee5\u6bd4\u4ef7\u65f6\u4e0d\u80fd\u53ea\u770b\u5916\u673a\u578b\u53f7\uff0c\u8981\u8fde\"\u98ce\u76d8\u51e0\u53f0 + \u9009\u6750\u4ec0\u4e48\u6863 + \u5b89\u88c5\u542b\u5230\u4ec0\u4e48\u7a0b\u5ea6 + \u5730\u6696\u542b\u4e0d\u542b\u56de\u586b\"\u4e00\u8d77\u770b\u3002\u672c\u9875\u540e\u9762\u7ed9\u7684\u6210\u5957\u533a\u95f4\uff0c\u90fd\u662f\u6309\u300c\u542b\u5730\u6696\u56de\u586b\u627e\u5e73\u3001\u6bdb\u576f\u65e0\u62c6\u6539\u300d\u7684\u524d\u63d0\u7ed9\u51fa\u7684\u3002\n<\/div>\n\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\u2462<\/span>\u65b9\u6848\u4e0e\u6210\u672c\uff1aFX \/ VF \u5168\u7cfb\u5217\u673a\u578b + \u6210\u5957\u9884\u7b97<\/h2>\n\n<h3 class=\"lmss-h3\">3.1 \u5148\u5206\u6e05\u4e24\u6761\u8def\u7ebf\uff1a\u6c1f\u6c34\u6362\u70ed\uff0c\u8fd8\u662f\u5168\u6c34\u7cfb\u7edf<\/h3>\n<p class=\"lmss-desc\">\u65e5\u7acb\u4e24\u8054\u4f9b\u6309\"\u6362\u70ed\u4ecb\u8d28\"\u5206\u4e24\u6761\u8def\u7ebf\u3002\u540d\u5b57\u53ea\u5dee\u4e24\u4e2a\u5b57\uff0c\u843d\u5730\u4f53\u9a8c\u548c\u9020\u4ef7\u5dee\u5f97\u4e0d\u5c11\uff0c\u52a1\u5fc5\u5148\u5bf9\u53f7\u5165\u5ea7\u3002<\/p>\n\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5bf9\u6bd4\u9879<\/th><th>\u5929\u6c34\u5730\u6c34\uff08\u6c34\u5885\u9002 \u00b7 \u5168\u6c34\u7cfb\u7edf\uff09<\/th><th>\u5929\u6c1f\u5730\u6c34\uff08\u667a\u4eab \u00b7 \u6c1f\u6c34\u6362\u70ed\uff09<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e3b\u673a\u4ea7\u51fa<\/td><td>\u4e3b\u673a\u76f4\u63a5\u4ea7\u51fa\u51b7\u51bb\u6c34 \/ \u6e29\u6c34<\/td><td>\u4e3b\u673a\u51fa\u6c1f\uff0c\u672b\u7aef\u518d\u6362\u70ed\u6210\u6c34\u8d70\u5730\u6696<\/td><\/tr>\n<tr><td>\u672b\u7aef\u5f62\u5f0f<\/td><td>\u98ce\u673a\u76d8\u7ba1 + \u6c34\u5730\u6696\uff0c\u540c\u6e90\u6c34\u7cfb\u7edf<\/td><td>\u6c1f\u7cfb\u7edf\u5ba4\u5185\u673a + \u6c34\u5730\u6696<\/td><\/tr>\n<tr><td>\u51fa\u98ce\u4f53\u611f<\/td><td class=\"lmss-price\">7\uff5e25\u2103\uff08\u8212\u9002\u533a 15\uff5e20\u2103\uff09\uff0c\u63a5\u8fd1\u81ea\u7136\u98ce\uff0c\u4e0d\u5e72\u71e5\u4e0d\u523a\u9aa8<\/td><td>\u6c1f\u673a\u76f4\u5439\uff0c\u51fa\u98ce\u6e29\u5ea6\u66f4\u4f4e\u3001\u66f4\u5e72\u71e5<\/td><\/tr>\n<tr><td>\u521d\u6295\u8d44<\/td><td>\u76f8\u5bf9\u66f4\u9ad8\uff08\u591a\u4e00\u6574\u5957\u6c34\u8def\u7cfb\u7edf\uff09<\/td><td>\u76f8\u5bf9\u7d27\u51d1\uff0c\u5165\u95e8\u95e8\u69db\u66f4\u4f4e<\/td><\/tr>\n<tr><td>\u53ef\u6269\u5c55\u6027<\/td><td>\u53ef\u5e73\u6ed1\u5347\u7ea7\u5168\u5c4b\u5168\u611f\u4e94\u6052\uff08\u51c0\u5316 + \u9664\u6e7f\u65b0\u98ce + \u52a0\u6e7f\uff09<\/td><td>\u4ee5\u4e24\u8054\u4f9b\u6807\u51c6\u5f62\u6001\u4e3a\u4e3b<\/td><\/tr>\n<tr><td>\u9002\u5408\u8c01<\/td><td>\u5728\u610f\u51fa\u98ce\u67d4\u548c\u3001\u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\u3001\u6709\u957f\u671f\u81ea\u4f4f\u8ba1\u5212<\/td><td>\u9884\u7b97\u4f18\u5148\u3001\u5e0c\u671b\u4e00\u6b65\u5230\u4f4d\u89e3\u51b3\u51b7\u6696<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<figure class=\"lmss-pic\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg\" alt=\"\u6c34\u673a\u7a7a\u8c03\u65bd\u5de5\u5e73\u9762\u56fe \u00b7 \u9f99\u8109\u6696\u901a\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u8d70\u5411\u8bbe\u8ba1\" width=\"1200\" height=\"800\" loading=\"lazy\">\n<figcaption>\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5e73\u9762\u56fe \u00b7 \u4e3b\u673a\u4e0e\u672b\u7aef\u4e4b\u95f4\u662f\u4e00\u6574\u6761\u6c34\u8def\uff0c\u7ba1\u8def\u8d70\u5411\u8981\u5728\u5f00\u5de5\u524d\u5c31\u5b9a\u6b7b<\/figcaption>\n<\/figure>\n\n<h4 class=\"lmss-h4\">\u4e3a\u4ec0\u4e48\u8bf4\"\u540c\u53eb\u6c34\u673a\uff0c\u914d\u7f6e\u53ef\u80fd\u5dee\u4e00\u6863\"<\/h4>\n<p>\u6237\u5f0f\u6c34\u673a\u8fd9\u51e0\u5e74\u7ecf\u5386\u4e86\u4e00\u8f6e\u660e\u663e\u8fed\u4ee3\uff1a\u65e9\u671f\u5bb6\u7528\u4ea7\u54c1\u6cbf\u7528\u7684\u662f\u5546\u7528\u51b7\u6c34\u673a\u7ec4\u7684\u5c0f\u578b\u5316\u601d\u8def\uff0c\u5b9a\u9891\u8fd0\u884c\u3001\u9760\u52a0\u5927\u6c34\u7bb1\u6765\u7a33\u4f4f\u6c34\u6e29\uff1b\u73b0\u5728\u7684\u4e3b\u6d41\u673a\u578b\u5219\u8d70\u5411<b>\u5168\u53d8\u9891 + \u6574\u4f53\u5f0f<\/b>\u2014\u2014\u538b\u7f29\u673a\u65e0\u7ea7\u53d8\u901f\u3001\u6c34\u6cf5\u4e0e\u538b\u7f29\u673a\u8054\u52a8\u3001\u6c34\u6a21\u5757\u4e0e\u5916\u673a\u96c6\u6210\u3002\u540c\u6837\u53eb\"\u6c34\u673a\"\uff0c\u4e0b\u9762\u56db\u9879\u5c31\u80fd\u62c9\u5f00\u5b9e\u9645\u4f53\u9a8c\uff1a<\/p>\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u770b\u54ea\u4e00\u9879<\/th><th>\u4f4e\u914d\u5e38\u89c1\u5f62\u6001<\/th><th>\u4e3b\u6d41\u5f62\u6001<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u538b\u7f29\u673a<\/td><td>\u5b9a\u9891 \/ \u5355\u8f6c\u5b50<\/td><td class=\"lmss-price\">\u5168\u53d8\u9891\u53cc\u8f6c\u5b50\uff08\u4e2d\u5c0f\u5339\u6570\uff09\u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb\uff08\u5927\u5339\u6570\uff09<\/td><\/tr>\n<tr><td>\u6c34\u6cf5<\/td><td>\u5b9a\u9891\u79bb\u5fc3\u6cf5\uff0c\u6ee1\u8d1f\u8377\u56fa\u5b9a\u8f6c\u901f<\/td><td class=\"lmss-price\">\u53d8\u9891\u5c4f\u853d\u6cf5 \/ \u53d8\u9891\u79bb\u5fc3\u6cf5\uff0c\u4e0e\u538b\u7f29\u673a\u8054\u52a8\uff0c\u529f\u8017\u968f\u8d1f\u8377\u4e0b\u964d<\/td><\/tr>\n<tr><td>\u7f13\u51b2\u6c34\u7bb1<\/td><td>\u6807\u914d\u5927\u6c34\u7bb1\u6765\u538b\u6c34\u6e29<\/td><td class=\"lmss-price\">\u7cfb\u7edf\u6c34\u91cf\u8fbe\u6807\u5373\u53ef\u514d\u6c34\u7bb1\uff08\u8be6\u89c1\u7b2c 4 \u7ae0\uff09<\/td><\/tr>\n<tr><td>\u4f4e\u6e29\u5236\u70ed<\/td><td>\u5e38\u89c4\u538b\u7f29\u673a\uff0c\u4f4e\u6e29\u8870\u51cf\u660e\u663e<\/td><td class=\"lmss-price\">\u8865\u6c14\u589e\u7113\uff0c\u8fd0\u884c\u73af\u6e29\u4e0b\u63a2\u81f3 -30\u2103<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"lmss-callout\">\n<b>\u4e00\u53e5\u8bdd\u9009\u578b\u903b\u8f91\uff1a<\/b>\u540c\u7b49\u6237\u578b\u4e0b\uff0c\"\u5168\u53d8\u9891 + \u6c34\u6cf5\u8054\u52a8 + \u7cfb\u7edf\u6c34\u91cf\u8fbe\u6807\"\u8fd9\u4e09\u4ef6\u4e8b\u505a\u5230\u4f4d\uff0c\u8fd0\u884c\u8d39\u7684\u5dee\u8ddd\u4f1a\u9010\u5e74\u663e\u73b0\u3002\u6240\u4ee5\u6bd4\u4ef7\u65f6\uff0c\u4e0e\u5176\u76ef\u7740\u5916\u673a\u6807\u4ef7\uff0c\u4e0d\u5982\u5148\u628a\u8fd9\u4e09\u9879\u7684\u914d\u7f6e\u95ee\u6e05\u695a\u3002\n<\/div>\n\n<h3 class=\"lmss-h3\">3.2 FX \u7cfb\u5217\u5168\u7cfb\u5217\u673a\u578b\u4e0e\u53c2\u8003\u4ef7<\/h3>\n<p class=\"lmss-desc\">FX \u662f\u6c34\u5885\u9002\u7684<b>\u6cf5\u5916\u7f6e\u7248\u672c<\/b>\uff1a\u4e3b\u673a\u4e0d\u5e26\u53d8\u9891\u6c34\u6cf5\u4e0e\u81a8\u80c0\u7f50\uff0c\u6539\u7531\u8bbe\u8ba1\u65bd\u5de5\u65b9\u9009\u914d\uff0c\u6240\u4ee5\u4ef7\u683c\u4f4e\u4e00\u622a\u3002<b>140\uff5e200 \u578b\u4e3a\u5355\u76f8 220V<\/b>\uff08\u4e2d\u5c0f\u6237\u578b\u3001\u53ef\u98d8\u7a97\u5b89\u88c5\uff09\uff0c<b>220\uff5e340 \u578b\u4e3a\u4e09\u76f8 380V<\/b>\uff08\u5927\u5e73\u5c42\u4e0e\u522b\u5885\uff0c220 \u578b\u53ca\u4ee5\u4e0a\u91c7\u7528\u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a\uff0c200 \u578b\u53ca\u4ee5\u4e0b\u4e3a\u53cc\u8f6c\u5b50\uff09\u3002\u5168\u7cfb\u4e00\u7ea7\u80fd\u6548\u3002<\/p>\n\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5bb9\u91cf\u578b<\/th><th>\u578b\u53f7<\/th><th>\u7535\u6e90 \/ \u5f62\u5f0f<\/th><th>\u989d\u5b9a\u5236\u51b7<\/th><th>\u989d\u5b9a\u5236\u70ed<\/th><th>\u53c2\u8003\u96f6\u552e\u4ef7<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>140 \u578b<\/td><td class=\"lmss-model\">RAS-140FPUEN2Q\/M<\/td><td>220V \u00b7 \u5355\u98ce\u6247\u53cc\u8f6c\u5b50<\/td><td>12.5 kW<\/td><td>13.5 kW<\/td><td class=\"lmss-price\">\u00a522,322<\/td><\/tr>\n<tr><td>160 \u578b<\/td><td class=\"lmss-model\">RAS-160FPUEN2Q\/M<\/td><td>220V \u00b7 \u5355\u98ce\u6247\u53cc\u8f6c\u5b50<\/td><td>14.0 kW<\/td><td>15.5 kW<\/td><td class=\"lmss-price\">\u00a524,830<\/td><\/tr>\n<tr><td>180 \u578b<\/td><td class=\"lmss-model\">RAS-180FPUEN2Q\/M<\/td><td>220V \u00b7 \u53cc\u98ce\u6247<\/td><td>16.0 kW<\/td><td>18.0 kW<\/td><td class=\"lmss-price\">\u00a530,110<\/td><\/tr>\n<tr><td>200 \u578b<\/td><td class=\"lmss-model\">RAS-200FPUEN2Q\/M<\/td><td>220V \u00b7 \u53cc\u98ce\u6247<\/td><td>18.0 kW<\/td><td>19.5 kW<\/td><td class=\"lmss-price\">\u00a534,450<\/td><\/tr>\n<tr><td>220 \u578b<\/td><td class=\"lmss-model\">RAS-220FPUENY2Q\/M<\/td><td>380V \u00b7 \u6da1\u65cb\u53cc\u98ce\u6247<\/td><td>20.0 kW<\/td><td>22.0 kW<\/td><td class=\"lmss-price\">\u00a541,900<\/td><\/tr>\n<tr><td>252 \u578b<\/td><td class=\"lmss-model\">RAS-252FPUENY2Q\/M<\/td><td>380V \u00b7 \u6da1\u65cb\u53cc\u98ce\u6247<\/td><td>22.4 kW<\/td><td>25.2 kW<\/td><td class=\"lmss-price\">\u00a544,500<\/td><\/tr>\n<tr><td>280 \u578b<\/td><td class=\"lmss-model\">RAS-280FPUENY2Q\/M<\/td><td>380V \u00b7 \u6da1\u65cb\u53cc\u98ce\u6247<\/td><td>25.2 kW<\/td><td>28.0 kW<\/td><td class=\"lmss-price\">\u00a546,188<\/td><\/tr>\n<tr><td>300 \u578b<\/td><td class=\"lmss-model\">RAS-300FPUENY2Q\/M<\/td><td>380V \u00b7 \u6da1\u65cb\u53cc\u98ce\u6247<\/td><td>28.0 kW<\/td><td>30.0 kW<\/td><td class=\"lmss-price\">\u00a549,500<\/td><\/tr>\n<tr><td>340 \u578b<\/td><td class=\"lmss-model\">RAS-340FPUENY2Q\/M<\/td><td>380V \u00b7 \u6da1\u65cb\u53cc\u98ce\u6247<\/td><td>32.0 kW<\/td><td>34.0 kW<\/td><td>\u4ee5\u95e8\u5e97\u5b9e\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"lmss-desc\">\u5907\u6ce8\uff1a\u4e0a\u8868\u4e3a<b>\u5916\u673a\u5355\u673a\u53c2\u8003\u4ef7<\/b>\uff0c\u4e0d\u542b\u98ce\u673a\u76d8\u7ba1\u3001\u6c34\u8def\u9009\u6750\u3001\u5b89\u88c5\u4e0e\u5730\u6696\uff1b\u6210\u5957\u4ef7\u683c\u89c1 3.5 \u8282\u3002\u4e09\u76f8 220 \u578b\u53ca\u4ee5\u4e0a\u673a\u578b\u6807\u914d\u8865\u6c14\u589e\u7113\uff0c\u8fd0\u884c\u73af\u6e29\u5236\u70ed\u53ef\u4e0b\u63a2\u81f3 -30\u2103\u3001\u5236\u51b7 -5\uff5e48\u2103\uff0c\u51fa\u6c34\u6e29\u5ea6\u5236\u70ed 25\uff5e55\u2103\u3001\u5236\u51b7 5\uff5e25\u2103\u3002<\/p>\n\n<h3 class=\"lmss-h3\">3.3 VF \u7cfb\u5217\u5168\u7cfb\u5217\u673a\u578b\u4e0e\u53c2\u8003\u4ef7<\/h3>\n<p class=\"lmss-desc\">VF \u662f\u6c34\u5885\u9002\u7684\u7ecf\u5178\u5168\u53d8\u9891\u4ea7\u54c1\u7ebf\uff0c\u8986\u76d6\u6bb5\u66f4\u5bbd\uff1a<b>80\uff5e180 \u578b\u4e3a\u5355\u76f8 220V \u5355\u98ce\u6247\u53cc\u8f6c\u5b50<\/b>\uff088\uff5e18kW\uff0c\u4e2d\u5c0f\u6237\u578b\u3001840mm \u8d85\u8584\u673a\u8eab\u53ef\u88c5\u98d8\u7a97\u4e0b\uff09\uff0c<b>200\uff5e500 \u578b\u4e3a\u4e09\u76f8 380V \u53cc\u98ce\u6247 \/ \u9876\u51fa\u98ce\u8865\u6c14\u589e\u7113\u6da1\u65cb<\/b>\uff0820\uff5e50kW\uff0c\u522b\u5885\u6d0b\u623f\uff0c\u6700\u591a\u53ef 4 \u53f0\u6a21\u5757\u7ec4\u5408\uff09\u3002<\/p>\n\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5bb9\u91cf\u578b<\/th><th>\u578b\u53f7<\/th><th>\u7535\u6e90 \/ \u5f62\u5f0f<\/th><th>\u80fd\u529b\u6bb5<\/th><th>\u53c2\u8003\u96f6\u552e\u4ef7<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>80 \u578b<\/td><td class=\"lmss-model\">RAS-80FWN3Q\/DM<\/td><td>\u5355\u76f8 220V \u00b7 \u53cc\u8f6c\u5b50<\/td><td>\u7ea6 8 kW<\/td><td>\u4ee5\u95e8\u5e97\u5b9e\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/td><\/tr>\n<tr><td>100 \u578b<\/td><td class=\"lmss-model\">RAS-100FWN3Q\/DM<\/td><td>\u5355\u76f8 220V \u00b7 \u53cc\u8f6c\u5b50<\/td><td>\u7ea6 10 kW<\/td><td>\u4ee5\u95e8\u5e97\u5b9e\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/td><\/tr>\n<tr><td>125 \u578b<\/td><td class=\"lmss-model\">RAS-125FWN3Q\/DM<\/td><td>\u5355\u76f8 220V \u00b7 \u53cc\u8f6c\u5b50<\/td><td>\u7ea6 12.5 kW<\/td><td>\u4ee5\u95e8\u5e97\u5b9e\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/td><\/tr>\n<tr><td>140 \u578b<\/td><td class=\"lmss-model\">RAS-140FWN3Q\/DM<\/td><td>\u5355\u76f8 220V \u00b7 \u53cc\u8f6c\u5b50<\/td><td>\u7ea6 14 kW<\/td><td>\u4ee5\u95e8\u5e97\u5b9e\u6d4b\u62a5\u4ef7\u4e3a\u51c6<\/td><\/tr>\n<tr><td>160 \u578b<\/td><td class=\"lmss-model\">RAS-160FWN3Q\/DM<\/td><td>\u5355\u76f8 220V \u00b7 \u53cc\u8f6c\u5b50<\/td><td>\u7ea6 16 kW<\/td><td class=\"lmss-price\">\u00a529,055<\/td><\/tr>\n<tr><td>180 \u578b<\/td><td class=\"lmss-model\">RAS-180FWN3Q\/DM<\/td><td>\u5355\u76f8 220V \u00b7 \u53cc\u8f6c\u5b50<\/td><td>\u7ea6 18 kW<\/td><td class=\"lmss-price\">\u00a544,345<\/td><\/tr>\n<tr><td>200 \u578b<\/td><td class=\"lmss-model\">RAS-200FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 20 kW<\/td><td class=\"lmss-price\">\u00a552,290<\/td><\/tr>\n<tr><td>224 \u578b<\/td><td class=\"lmss-model\">RAS-224FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 22.4 kW<\/td><td class=\"lmss-price\">\u00a565,860<\/td><\/tr>\n<tr><td>252 \u578b<\/td><td class=\"lmss-model\">RAS-252FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 25.2 kW<\/td><td class=\"lmss-price\">\u00a566,810<\/td><\/tr>\n<tr><td>280 \u578b<\/td><td class=\"lmss-model\">RAS-280FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 28 kW<\/td><td class=\"lmss-price\">\u00a577,450<\/td><\/tr>\n<tr><td>320 \u578b<\/td><td class=\"lmss-model\">RAS-320FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 32 kW<\/td><td class=\"lmss-price\">\u00a583,880<\/td><\/tr>\n<tr><td>400 \u578b<\/td><td class=\"lmss-model\">RAS-400FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 40 kW<\/td><td class=\"lmss-price\">\u00a591,618<\/td><\/tr>\n<tr><td>500 \u578b<\/td><td class=\"lmss-model\">RAS-500FEWNY3Q\/DM<\/td><td>\u4e09\u76f8 380V \u00b7 \u8865\u6c14\u589e\u7113\u6da1\u65cb<\/td><td>\u7ea6 50 kW<\/td><td class=\"lmss-price\">\u00a5108,388<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"lmss-warn\">\n<b>\u5173\u4e8e\u8868\u5355\u91cc\u7684\"\u2014\"\uff1a<\/b>80\uff5e140 \u578b\u5c5e\u5355\u76f8\u5c0f\u5bb9\u91cf\u6bb5\uff0c\u4e3b\u8981\u4f5c\u7528\u662f\u7ed9\u5c0f\u6237\u578b\u6216\u590d\u5f0f\u5355\u5c42\u505a\u5339\u914d\u9009\u578b\uff0c\u5b9e\u9645\u62a5\u4ef7\u968f\u98ce\u76d8\u6570\u91cf\u3001\u6c34\u8def\u6863\u4f4d\u4e0e\u5b89\u88c5\u6761\u4ef6\u6d6e\u52a8\uff0c\u4e0d\u9002\u5408\u7528\u5355\u4e00\u6570\u5b57\u5bf9\u5916\u627f\u8bfa\uff0c\u56e0\u6b64\u5199\u4e3a\"\u4ee5\u95e8\u5e97\u5b9e\u6d4b\u62a5\u4ef7\u4e3a\u51c6\"\u3002\u9700\u8981\u8fd9\u56db\u4e2a\u6863\u4f4d\u7684\u660e\u786e\u4ef7\u683c\uff0c\u8bf7\u8ba9\u987e\u95ee\u6309\u60a8\u7684\u6237\u578b\u51fa\u914d\u7f6e\u6e05\u5355\u3002\n<\/div>\n\n<h3 class=\"lmss-h3\">3.4 FX \u4e0e VF \u600e\u4e48\u9009<\/h3>\n<p class=\"lmss-desc\">\u4e24\u6761\u7ebf\u4e0d\u662f\"\u8c01\u66ff\u4ee3\u8c01\"\uff0c\u800c\u662f\u8986\u76d6\u6bb5\u4e0d\u540c\u3001\u914d\u7f6e\u601d\u8def\u4e0d\u540c\u3002\u5148\u770b\u5dee\u5f02\uff0c\u518d\u5bf9\u53f7\u5165\u5ea7\u3002<\/p>\n\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5bf9\u6bd4\u9879<\/th><th>VF \u7cfb\u5217<\/th><th>FX \u7cfb\u5217<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4ea7\u54c1\u5b9a\u4f4d<\/td><td>\u6574\u673a\u7248\uff0c\u6cf5\u4e0e\u81a8\u80c0\u7f50\u51fa\u5382\u6807\u914d<\/td><td>\u6cf5\u5916\u7f6e\u7248\uff0c\u4e3b\u673a\u4e0d\u5e26\u6cf5\u4e0e\u7f50<\/td><\/tr>\n<tr><td>\u80fd\u6548\u7b49\u7ea7<\/td><td>\u4e00\u7ea7\u80fd\u6548<\/td><td>\u4e00\u7ea7\u80fd\u6548\uff08APF 3.20\uff5e3.35\uff09<\/td><\/tr>\n<tr><td>\u5236\u70ed COP<\/td><td>3.08\uff5e3.70<\/td><td>3.00\uff5e3.50<\/td><\/tr>\n<tr><td>\u8fd0\u884c\u73af\u6e29\uff08\u5236\u70ed\uff09<\/td><td>-30\uff5e28\u2103<\/td><td>-30\uff5e28\u2103<\/td><\/tr>\n<tr><td>\u51fa\u6c34\u6e29\u5ea6\uff08\u5236\u70ed\uff09<\/td><td>25\uff5e55\u2103<\/td><td>25\uff5e55\u2103<\/td><\/tr>\n<tr><td>\u5355\u76f8\u8986\u76d6\u6bb5<\/td><td>80\uff5e180 \u578b<\/td><td class=\"lmss-price\">140\uff5e200 \u578b<\/td><\/tr>\n<tr><td>\u4e09\u76f8\u8986\u76d6\u6bb5<\/td><td class=\"lmss-price\">200\uff5e500 \u578b<\/td><td>220\uff5e340 \u578b<\/td><\/tr>\n<tr><td>\u6c34\u6cf5\u914d\u7f6e<\/td><td>\u5185\u7f6e\u53d8\u9891\u6cf5\uff0c\u51fa\u5382\u5373\u914d<\/td><td>\u5916\u7f6e\u9009\u914d\u6cf5\uff0c\u53ef\u6309\u9700\u52a0\u88c5<\/td><\/tr>\n<tr><td>\u4e00\u53e5\u8bdd<\/td><td>\u51fa\u5382\u4e00\u4f53\u5316\u914d\u5957\uff0c\u4e0d\u7528\u518d\u9009\u6cf5\u3001\u4e5f\u4e0d\u7528\u81ea\u5df1\u5199\u63a7\u5236\u903b\u8f91<\/td><td>\u4ef7\u683c\u4f4e\u4e00\u622a\uff0c\u4f46\u6cf5\u7684\u9009\u578b\u4e0e\u8054\u52a8\u8981\u7531\u65bd\u5de5\u65b9\u505a<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h4 class=\"lmss-h4\">\u5916\u673a\u9009\u578b\u901f\u67e5<\/h4>\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5bb6\u5ead\u60c5\u51b5<\/th><th>\u63a8\u8350\u7cfb\u5217<\/th><th>\u4e3b\u8981\u7406\u7531<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e2d\u5c0f\u6237\u578b 60\uff5e150\u33a1<br>220V \u00b7 \u98d8\u7a97\u4e0b\u5b89\u88c5<\/td><td class=\"lmss-price\">VF \/ FX \u5355\u98ce\u6247\u53cc\u8f6c\u5b50<\/td><td>840mm \u8d85\u8584\u673a\u8eab\u53ef\u88c5\u98d8\u7a97\u4e0b\uff1b220V \u5bb6\u7528\u7535\u6e90\u65e0\u9700\u589e\u5bb9\uff1b\u5168\u53d8\u9891\u6309\u9700\u8f93\u51fa\u66f4\u8282\u80fd<\/td><\/tr>\n<tr><td>\u5927\u5b85 \/ \u522b\u5885 150\uff5e400\u33a1+<br>380V \u00b7 \u591a\u672b\u7aef<\/td><td class=\"lmss-price\">VF \u53cc\u98ce\u6247 \/ \u9876\u51fa\u98ce\u6da1\u65cb<\/td><td>\u8865\u6c14\u589e\u7113\uff0c-30\u2103 \u7a33\u5b9a\u5236\u70ed\uff1b380V \u6700\u591a\u53ef 4 \u53f0\u6a21\u5757\u7ec4\u5408\uff0c\u8986\u76d6\u8d85\u5927\u7cfb\u7edf<\/td><\/tr>\n<tr><td>\u9884\u7b97\u654f\u611f \u00b7 \u65bd\u5de5\u65b9\u6709\u6c34\u7cfb\u7edf\u80fd\u529b<\/td><td class=\"lmss-price\">FX \u7cfb\u5217<\/td><td>\u6c34\u6cf5\u5916\u7f6e\u9009\u914d\uff0c\u4ef7\u683c\u4f4e\u4e00\u622a\uff1b\u4f46\u6cf5\u7684\u81ea\u9002\u5e94\u63a7\u5236\u4e0e\u8054\u52a8\u8981\u7531\u65bd\u5de5\u65b9\u914d\u597d\uff0c\u914d\u4e0d\u597d\u7cfb\u7edf\u8dd1\u4e0d\u7a33<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"lmss-callout\">\n<b>\u600e\u4e48\u5feb\u901f\u5224\u65ad\uff1a<\/b>\u5148\u770b\u5bb6\u91cc\u7684\u7535\u2014\u2014\u53ea\u6709 220V \u5355\u76f8\u3001\u6237\u578b\u5728 150\u33a1 \u4ee5\u5185\uff0c\u57fa\u672c\u843d\u5728 VF 80\uff5e180 \u578b\u6216 FX 140\uff5e200 \u578b\uff1b\u6709\u4e09\u76f8\u7535\u3001\u9762\u79ef 150\u33a1 \u4ee5\u4e0a\u6216\u9700\u8981\u591a\u53f0\u5e76\u8054\uff0c\u8d70 VF 200 \u578b\u4ee5\u4e0a\u6216 FX 220 \u578b\u4ee5\u4e0a\u3002\u5177\u4f53\u6863\u4f4d\u7531\u4e0a\u95e8\u52d8\u6d4b\u7684\u51b7\u70ed\u8d1f\u8377\u6d4b\u7b97\u786e\u5b9a\uff0c\u4e0d\u9760\"\u6309\u9762\u79ef\u5957\u6863\"\u3002\n<\/div>\n\n<h3 class=\"lmss-h3\">3.5 \u4e00\u62d6\u56db \/ \u4e94 \/ \u516d \u00b7 \u6210\u90fd\u6210\u5957\u9884\u7b97\u533a\u95f4<\/h3>\n<p class=\"lmss-desc\">\u4e0b\u9762\u4e09\u6863\u662f\u6210\u90fd\u672c\u5730\u300c\u7a7a\u8c03 + \u5730\u6696\u6574\u5957\u300d\u7684\u6210\u4ea4\u53c2\u8003\u533a\u95f4\uff0c\u53e3\u5f84\u7edf\u4e00\u4e3a<b>\u542b\u5730\u6696\u56de\u586b\u627e\u5e73\u3001\u6bdb\u576f\u65b0\u623f\u3001\u65e0\u62c6\u6539<\/b>\u3002\u8fd9\u662f\u4e0e\"\u53ea\u5e26\u8bbe\u5907\u3001\u5b89\u88c5\u53e6\u7b97\"\u7684\u62a5\u4ef7\u5173\u952e\u7684\u533a\u522b\uff0c\u6bd4\u4ef7\u65f6\u8bf7\u5148\u5bf9\u9f50\u53e3\u5f84\u3002<\/p>\n\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u6210\u5957\u914d\u7f6e<\/th><th>\u53c2\u8003\u533a\u95f4\uff08\u7a7a\u8c03+\u5730\u6696\u6574\u5957\uff09<\/th><th>\u57fa\u7840\u914d\u7f6e\u524d\u63d0<\/th><th>\u9002\u5408\u6237\u578b<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u6c34\u5885\u9002 \u4e00\u62d6\u56db<\/td><td class=\"lmss-price\">\u00a564,900 \u2011 81,799<\/td><td>\u6c34\u673a\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\uff0c\u542b\u5730\u6696\u56de\u586b\u627e\u5e73\uff1b\u4e0d\u542b\u62c6\u9664\u6539\u9020\uff0c\u6bdb\u576f\u65e0\u62c6\u6539<\/td><td>110\uff5e140\u33a1 \u8ffd\u6c42\u67d4\u548c\u9001\u98ce<\/td><\/tr>\n<tr><td>\u6c34\u5885\u9002 \u4e00\u62d6\u4e94<\/td><td class=\"lmss-price\">\u00a585,000 \u2011 95,000<\/td><td>\u540c\u4e0a\uff1b\u4e00\u62d6\u4e94\u6574\u5957<\/td><td>130\uff5e160\u33a1 \u5927\u5e73\u5c42<\/td><\/tr>\n<tr><td>\u6c34\u5885\u9002 \u4e00\u62d6\u516d<\/td><td class=\"lmss-price\">\u00a585,000 \u2011 98,000<\/td><td>\u540c\u4e0a\uff1b\u4e00\u62d6\u516d\u6574\u5957<\/td><td>150\uff5e190\u33a1 \u5927\u5e73\u5c42 \/ \u522b\u5885<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"lmss-warn\">\n<b>\u533a\u95f4\u4e3a\u4ec0\u4e48\u6709 1.5\uff5e1.7 \u4e07\u7684\u5bbd\u5ea6\uff1a<\/b>\u4e0b\u9650\u4e3a\u57fa\u7840\u914d\u7f6e\uff08\u6807\u51c6\u5185\u673a\u3001\u57fa\u7840\u5206\u96c6\u6c34\u5668\uff09\uff1b\u4e0a\u9650\u542b\u5347\u7ea7 PE \u7eaf\u51c0\u751f\u6001\u51c0\u5316\u578b\u5185\u673a\u3001\u667a\u6167\u96c6\u63a7\u5c4f\u8054\u52a8\u5168\u5c4b\u5168\u611f\u3001\u5916\u673a\u89c4\u683c\u4e0a\u6d6e\u4e0e\u65bd\u5de5\u590d\u6742\u5ea6\u63d0\u5347\u3002\u533a\u95f4\u4e0d\u662f\"\u4ef7\u683c\u6c34\u5206\"\uff0c\u800c\u662f\u914d\u7f6e\u6863\u4f4d\u5dee\u3002\u8981\u8ba9\u62a5\u4ef7\u843d\u5230\u533a\u95f4\u7684\u54ea\u4e00\u6bb5\uff0c\u53d6\u51b3\u4e8e\u9009\u914d\u6e05\u5355\u3002\n<\/div>\n\n<h4 class=\"lmss-h4\">\u533a\u95f4\u80cc\u540e\u7684\u771f\u5b9e\u6210\u4ea4\u951a\u70b9\uff08\u8131\u654f\uff09<\/h4>\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u914d\u7f6e<\/th><th>\u6210\u4ea4\u53c2\u8003<\/th><th>\u9879\u76ee\u951a\u70b9\uff08\u8131\u654f\uff09<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e00\u62d6\u56db<\/td><td>\u00a564,900<\/td><td>\u60a6\u84c9\u4e1c\u65b9 4-1-102 \u00b7 140 \u578b\u4e3b\u673a<\/td><\/tr>\n<tr><td>\u4e00\u62d6\u56db<\/td><td>\u7ea6 \u00a565,000<\/td><td>\u8a89\u6d6a\u4e1c\u671b \u00b7 160 \u578b\u4e3b\u673a<\/td><\/tr>\n<tr><td>\u4e00\u62d6\u4e94<\/td><td>\u00a588,500<\/td><td>\u4e2d\u6d77\u6d63\u4e91\u5c45 \u00b7 140 \u578b\u4e3b\u673a\u4e00\u62d6\u4e94<\/td><\/tr>\n<tr><td>\u4e00\u62d6\u516d<\/td><td>\u00a591,156<\/td><td>\u4fdd\u5229\u5927\u56fd\u749f \u00b7 160 \u578b\u4e3b\u673a\u4e00\u62d6\u516d<\/td><\/tr>\n<tr><td>\u4e00\u62d6\u516d<\/td><td>\u00a585,000<\/td><td>160 \u578b\uff08\u4e09\u76f8\u8865\u6c14\u589e\u7113\uff09\u4e00\u62d6\u516d<\/td><\/tr>\n<tr><td>\u4e00\u62d6\u516d\u5927\u6237\u578b<\/td><td>\u00a598,000<\/td><td>\u68e0\u6e56\u67cf\u6797\u57ce \u00b7 180 \u578b\u4e3b\u673a<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3 class=\"lmss-h3\">3.6 \u9664\u4e86\u4e3b\u673a\uff0c\u8fd8\u4f1a\u82b1\u54ea\u4e9b\u94b1<\/h3>\n<p class=\"lmss-desc\">\u8fd9\u4e00\u8282\u662f\u628a 3.5 \u7684\"\u6574\u5957\u533a\u95f4\"\u62c6\u5f00\u7ed9\u60a8\u770b\u3002\u5217\u51fa\u6765\u4e0d\u662f\u8ba9\u60a8\u81ea\u5df1\u7b97\u603b\u4ef7\uff0c\u800c\u662f\u5f53\u60a8\u62ff\u5230\u522b\u4eba\u7684\u62a5\u4ef7\u65f6\uff0c\u53ef\u4ee5\u9010\u9879\u5bf9\u7167\"\u54ea\u4e00\u9879\u5c11\u4e86\"\u3002<\/p>\n\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u5206\u9879<\/th><th>\u8ba1\u8d39\u65b9\u5f0f<\/th><th>\u53c2\u8003\u4ef7<\/th><th>\u542b\u4ec0\u4e48<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5<\/td><td>\u6309\u5957<\/td><td class=\"lmss-price\">200 \u578b\u53ca\u4ee5\u5185\u7ea6 3,600 \u5143\/\u5957<br>220 \u578b\u53ca\u4ee5\u4e0a\u7ea6 4,000 \u5143\/\u5957<br>\u522b\u5885\u9876\u51fa\u98ce\u7ea6 4,200 \u5143\/\u5957<\/td><td>\u542b\u6750\u6599\u53ca\u4eba\u5de5\u5b89\u88c5\uff1b<b>\u4e0d\u542b<\/b>\u5916\u673a\u7535\u6e90\u7ebf\u53ca\u642d\u5efa\uff0c\u5916\u673a\u540a\u88c5\u8d39\u7528\u53e6\u8ba1<\/td><\/tr>\n<tr><td>\u6c34\u7cfb\u7edf\u9009\u6750<\/td><td>\u6309\u98ce\u76d8<\/td><td class=\"lmss-price\">5 \u5339\/125 \u578b\u53ca\u4ee5\u5185\u7ea6 1,700 \u5143\/\u98ce\u76d8<br>6 \u5339\/140\uff5e180 \u578b\u7ea6 1,800 \u5143\/\u98ce\u76d8<br>8 \u5339\/200\uff5e280 \u578b\u7ea6 2,000 \u5143\/\u98ce\u76d8<br>320 \u578b\u4ee5\u4e0a\u7ea6 2,200 \u5143\/\u98ce\u76d8<\/td><td>\u4e3b\u7ba1 + \u652f\u7ba1 + \u98ce\u76d8\u9600\u95e8 + \u914d\u4ef6 + \u4fdd\u6e29<\/td><\/tr>\n<tr><td>\u8bbe\u8ba1\u5b9a\u4f4d \/ \u76d1\u7406 \/ \u8054\u4fdd \/ \u8c03\u8bd5<\/td><td>\u6309\u98ce\u76d8<\/td><td class=\"lmss-price\">\u7ea6 2,000 \u5143\/\u98ce\u76d8<\/td><td>\u8bbe\u8ba1\u5b9a\u4f4d\u3001\u5b89\u88c5\u76d1\u7406\u3001\u7ba1\u9053\u8054\u4fdd\u3001\u7cfb\u7edf\u8c03\u8bd5<\/td><\/tr>\n<tr><td>\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1<\/td><td>\u6309\u53f0<\/td><td class=\"lmss-price\">\u7ea6 2,625 \uff5e 4,930 \u5143\/\u53f0<\/td><td>192mm \u8d85\u8584\u673a\u8eab\u3001\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\uff0c\u53ef\u9009\u914d PE \u51c0\u5316\u6a21\u5757<\/td><\/tr>\n<tr><td>\u5730\u6696\uff08\u6309\u91c7\u6696\u9762\u79ef\uff09<\/td><td>\u5143\/\u33a1<\/td><td class=\"lmss-price\">99 \/ 119 \/ 169 \/ 179 \u5143\/\u33a1<\/td><td>\u76d8\u7ba1 + \u6324\u5851\u677f\u6216\u767d\u6676\u677f + \u56de\u586b + \u5206\u96c6\u6c34\u5668\u4e0e\u8054\u52a8\uff08\u6309\u6240\u9009\u5957\u9910\u6863\uff09<\/td><\/tr>\n<tr><td>\u53ef\u9009\u5347\u7ea7<\/td><td>\u6309\u9879<\/td><td class=\"lmss-price\">\u591a\u54c1\u724c\u7ec4\u5408\u8054\u52a8\uff08\u542b\u5730\u6696\uff09\u7ea6 1,800 \u5143<br>\u7f13\u51b2\u6c34\u7bb1\u542b\u65c1\u901a\u7ec4\u4ef6\u7ea6 2,600 \u5143\/\u5957<br>\u4e8c\u6b21\u4fa7\u53d8\u9891\u6cf5\u7ea6 2,200 \u5143\/\u4e2a<\/td><td>\u6309\u7cfb\u7edf\u590d\u6742\u5ea6\u6309\u9700\u9009\u914d<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"lmss-callout\">\n<b>\u4f1a\u5458\u6743\u76ca\uff1a<\/b>\u9f99\u8109\u6696\u901a\u4f1a\u5458\u53ef\u4eab\u4f1a\u5458\u4ef7 + \u5ef6\u4fdd + \u4f1a\u5458\u4e13\u5c5e\u798f\u5229\u3002\u5177\u4f53\u6743\u76ca\u4ee5\u5f53\u671f\u4f1a\u5458\u653f\u7b56\u4e3a\u51c6\uff0c\u53ef\u5230\u5e97\u6216\u7535\u8bdd\u54a8\u8be2\u3002\n<\/div>\n\n<h3 class=\"lmss-h3\">3.7 20 \u5e74\u603b\u8d26\u600e\u4e48\u7b97<\/h3>\n<p class=\"lmss-desc\">\u6c34\u673a\u4e24\u8054\u4f9b\u6bd4\u6c1f\u673a\u591a\u82b1\u7684\u521d\u88c5\u94b1\uff0c\u4e3b\u8981\u9760\u91c7\u6696\u5b63\u7684\u8fd0\u884c\u8d39\u5dee\u56de\u6765\u3002\u603b\u8d26\u7684\u7b97\u6cd5\u5f88\u7b80\u5355\uff0c\u5173\u952e\u662f\u522b\u53ea\u770b\u521d\u88c5\u6807\u4ef7\u3002<\/p>\n<div class=\"lmss-card\">\n<div class=\"lmss-card-h\"><span class=\"lmss-ic\">\ud83e\uddee<\/span>\u603b\u8d26\u516c\u5f0f<\/div>\n<p style=\"font-size:15.5px;margin-bottom:10px\"><b>20 \u5e74\u603b\u8d26 = \u521d\u88c5\u6295\u5165 +\uff08\u5e74\u8fd0\u884c\u8d39 + \u5e74\u7ef4\u62a4\u8d39\uff09\u00d7 20<\/b><\/p>\n<p>\u5176\u4e2d\u8fd0\u884c\u8d39\u53d7\u4e09\u4ef6\u4e8b\u5f71\u54cd\uff1a<b>\u623f\u5c4b\u4fdd\u6e29<\/b>\u3001<b>\u4f7f\u7528\u4e60\u60ef<\/b>\u3001<b>\u5f53\u5730\u7535\u4ef7\u4e0e\u71c3\u6c14\u4ef7<\/b>\u3002\u6240\u4ee5\u4efb\u4f55\u4e00\u5bb6\u7684\"20 \u5e74\u7701 XX \u4e07\"\u90fd\u53ea\u80fd\u5f53\u53c2\u8003\uff0c\u4e0d\u80fd\u5f53\u627f\u8bfa\u3002<\/p>\n<p style=\"margin-bottom:0\"><b>\u6210\u90fd\u771f\u5b9e\u6848\u4f8b\u53e3\u5f84\uff1a<\/b>\u57fa\u4e8e\u6210\u90fd\u5df2\u5b8c\u5de5\u540c\u6237\u578b\u6848\u4f8b\u5bf9\u6807\uff0c\u5728\u540c\u7b49\u4f7f\u7528\u4e60\u60ef\u524d\u63d0\u4e0b\uff0c\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u91c7\u6696\u5b63\u8fd0\u884c\u8d39\u7528\u76f8\u6bd4\u71c3\u6c14\u58c1\u6302\u7089<b>\u6709\u673a\u4f1a\u8282\u7701\u7ea6 40%<\/b>\uff08\u5b9e\u9645\u8d39\u7528\u53d7\u623f\u5c4b\u4fdd\u6e29\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u7535\u4ef7\u4e0e\u71c3\u6c14\u4ef7\u683c\u6ce2\u52a8\u5f71\u54cd\uff0c\u4ec5\u4f9b\u65b9\u6848\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u6bcf\u6237\u627f\u8bfa\uff09\u3002<\/p>\n<\/div>\n\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\u2463<\/span>\u65bd\u5de5\u4ea4\u4ed8\uff1a\u6c34\u673a\u597d\u4e0d\u597d\u7528\uff0c\u4e00\u534a\u770b\u5b89\u88c5<\/h2>\n<p class=\"lmss-desc\">\u6c34\u673a\u662f\u4e00\u5957\"\u6c34\u8def\u7cfb\u7edf\"\uff0c\u6bd4\u6c1f\u673a\u591a\u4e86\u6c34\u5faa\u73af\u8fd9\u4e00\u73af\u3002\u7ba1\u8def\u8d70\u5411\u3001\u4fdd\u538b\u3001\u6392\u6c14\u3001\u8c03\u8bd5\u4efb\u4f55\u4e00\u4e2a\u73af\u8282\u9a6c\u864e\uff0c\u90fd\u4f1a\u53d8\u6210\u540e\u671f\u7684\u9ad8\u9891\u6545\u969c\u3002\u6240\u4ee5\u8fd9\u4e00\u7ae0\u8bb2\u7684\u662f\uff1a\u94b1\u82b1\u5230\u54ea\u4e00\u6b65\uff0c\u6d3b\u5fc5\u987b\u5e72\u5230\u4ec0\u4e48\u6807\u51c6\u3002<\/p>\n\n<h3 class=\"lmss-h3\">4.1 \u6c34\u673a\u843d\u5730\u7684\u516d\u4e2a\u5173\u952e\u8282\u70b9<\/h3>\n<ol class=\"lmss-steps\">\n<li><b>\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u8d1f\u8377\u6d4b\u7b97\u3002<\/b>\u6309\u6210\u90fd\"\u590f\u70ed\u51ac\u51b7\u3001\u51ac\u5b63\u6e7f\u51b7\"\u6c14\u5019\u7279\u5f81\uff0c\u7a7a\u8c03\u6309\u5236\u51b7 160W\/\u33a1\u3001\u5730\u6696 200W\/\u33a1 \u6821\u6838\uff1b\u4e3b\u673a\u8fde\u63a5\u7387\u63a7\u5236\u5728\u5382\u5bb6\u5141\u8bb8\u533a\u95f4\uff08\u7ea6 50%\uff5e130%\uff09\u3002<b>\u4e0d\u6309\u9762\u79ef\u76f4\u63a5\u5957\u6863<\/b>\uff0c\u8fd9\u662f\u6c34\u673a\u9009\u578b\u7684\u7b2c\u4e00\u9053\u5173\u3002<\/li>\n<li><b>\u65b9\u6848\u8bbe\u8ba1\u4e0e\u7ba1\u8def\u8d70\u5411\u3002<\/b>\u6c34\u673a\u4e0e\u672b\u7aef\u4e4b\u95f4\u662f\u4e00\u6574\u6761\u6c34\u8def\uff0c\u4e3b\u7ba1\u8d70\u5411\u3001\u7ba1\u5f84\u7ec4\u5408\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u90fd\u8981\u5728\u5f00\u5de5\u524d\u5b9a\u6b7b\uff0c\u907f\u514d\u540e\u671f\u6539\u7ba1\u3002<\/li>\n<li><b>\u5185\u673a\u540a\u88c5\u4e0e\u51b7\u51dd\u6c34\u3002<\/b>\u98ce\u673a\u76d8\u7ba1\u540a\u88c5\u6c34\u5e73\u5ea6\u3001\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u4e0e\u6392\u6c34\u5761\u5411\uff0c\u76f4\u63a5\u5173\u7cfb\u5230\u540e\u671f\u4f1a\u4e0d\u4f1a\u6e17\u6c34\u3001\u566a\u97f3\u5927\u4e0d\u5927\u3002<\/li>\n<li><b>\u6c34\u8def\u5b89\u88c5\u4e0e\u4fdd\u538b\u3002<\/b>\u4e3b\u7ba1 + \u652f\u7ba1 + \u98ce\u76d8\u9600\u95e8 + \u914d\u4ef6 + \u4fdd\u6e29\u6210\u5957\u65bd\u5de5\uff0c\u9690\u853d\u524d\u505a\u4fdd\u538b\u8bd5\u9a8c\u5e76\u7559\u5b58\u8bb0\u5f55\u3002<\/li>\n<li><b>\u5730\u6696\u76d8\u7ba1\u4e0e\u56de\u586b\u3002<\/b>\u76d8\u7ba1\u95f4\u8ddd\u3001\u56de\u8def\u957f\u5ea6\u3001\u4fdd\u6e29\u677f\u94fa\u8bbe\u3001\u56de\u586b\u627e\u5e73\uff0c\u5c5e\u9690\u853d\u5de5\u7a0b\uff0c\u8282\u70b9\u7559\u5b58\u9a8c\u6536\u5355\u3002<\/li>\n<li><b>\u53cc\u6a21\u5f0f\u8c03\u8bd5\u4e0e\u9a8c\u6536\u3002<\/b>\u5236\u51b7\u3001\u5236\u70ed\u4e24\u4e2a\u6a21\u5f0f\u5206\u522b\u8c03\u8bd5\uff0c\u786e\u8ba4\u51fa\u6c34\u6e29\u5ea6\u3001\u6c34\u6d41\u91cf\u4e0e\u672b\u7aef\u54cd\u5e94\uff0c\u518d\u4ea4\u4ed8\u3002<\/li>\n<\/ol>\n\n<figure class=\"lmss-pic\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxtylt.jpg\" alt=\"\u65e5\u7acb\u6c34\u5885\u9002FX\u5355\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe \u00b7 \u9f99\u8109\u6696\u901a\u6c34\u673a\u4e24\u8054\u4f9b\u7cfb\u7edf\u8bbe\u8ba1\u56fe\u7eb8\" width=\"1400\" height=\"900\" loading=\"lazy\">\n<figcaption>\u6c34\u5885\u9002 FX \u5355\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe \u00b7 \u4e3b\u673a\u76f4\u8fde\u672b\u7aef\uff0c\u7cfb\u7edf\u7ed3\u6784\u6e05\u6670<\/figcaption>\n<\/figure>\n\n<h3 class=\"lmss-h3\">4.2 \u7f13\u51b2\u6c34\u7bb1\u5230\u5e95\u8981\u4e0d\u8981\u914d<\/h3>\n<p class=\"lmss-desc\">\u8fd9\u662f\u6c34\u673a\u62a5\u4ef7\u91cc\u8f83\u5bb9\u6613\"\u987a\u624b\u52a0\u4e00\u7b14\"\u7684\u9879\u76ee\uff0c\u4e5f\u662f\u66f4\u8be5\u8bb2\u6e05\u695a\u7684\u4e00\u9879\u2014\u2014\u5b83\u53d6\u51b3\u4e8e<b>\u7cfb\u7edf\u603b\u6c34\u91cf<\/b>\uff0c\u4e0d\u662f\"\u914d\u4e86\u4e00\u5b9a\u66f4\u7a33\"\u3002<\/p>\n\n<div class=\"lmss-card\">\n<div class=\"lmss-card-h\"><span class=\"lmss-ic\">\ud83d\udca7<\/span>\u5224\u65ad\u6807\u51c6\u4e0e\u5b9e\u6d4b\u6848\u4f8b<\/div>\n<p><b>\u65e5\u7acb\u6c34\u5885\u9002\u5b98\u65b9\u6807\u51c6\uff1a\u6240\u9700\u6c34\u5bb9\u91cf\u4e0b\u9650 = \u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf\uff08kW\uff09\u00d7 2\u3002<\/b><\/p>\n<p>\u4ee5\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u6c64\u5148\u751f\u5bb6\u4e3a\u4f8b\uff08\u5957\u5185\u7ea6 90\u33a1\u3001\u91c7\u6696\u7ea6 77\u33a1\uff0c\u4e3b\u673a RAS-160F\u5168\u53d8\u9891\uff0c\u540d\u4e49\u5236\u51b7\u91cf\u7ea6 16kW\uff09\uff1a<\/p>\n<div class=\"lmss-tblwrap\">\n<table>\n<thead><tr><th>\u9879\u76ee<\/th><th>\u6570\u503c<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u6240\u9700\u6c34\u5bb9\u91cf\u4e0b\u9650\uff0816kW \u00d7 2\uff09<\/td><td>32 L<\/td><td>\u5382\u5bb6\u6807\u51c6<\/td><\/tr>\n<tr><td>\u672c\u6848\u7cfb\u7edf\u603b\u6c34\u91cf\uff08\u5b9e\u6d4b\uff09<\/td><td class=\"lmss-price\">\u7ea6 76 L<\/td><td>\u8d85\u6807 2.4 \u500d<\/td><\/tr>\n<tr><td>\u662f\u5426\u9700\u8981\u7f13\u51b2\u6c34\u7bb1<\/td><td colspan=\"2\" class=\"lmss-price\">\u5b8c\u5168\u65e0\u9700\u7f13\u51b2\u6c34\u7bb1<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin-top:12px;margin-bottom:0\">\u514d\u6c34\u7bb1\u7684\u597d\u5904\u5f88\u76f4\u63a5\uff1a\u7cfb\u7edf\u7ed3\u6784\u66f4\u7b80\u6d01\u3001\u6f5c\u5728\u6545\u969c\u70b9\u66f4\u5c11\u3001\u5f00\u673a\u54cd\u5e94\u66f4\u5feb\uff0c\u8fd8\u7701\u6389\u6c34\u7bb1\u7684\u5360\u5730\u4e0e\u8d39\u7528\u3002\u5bf9\u4e8e\u5168\u53d8\u9891\u4e3b\u673a\u3001\u7cfb\u7edf\u6c34\u91cf\u5df2\u7ecf\u8fbe\u6807\u7684\u6237\u578b\uff0c\u8fd9\u662f\u66f4\u4f18\u89e3\uff1b\u53cd\u4e4b\uff0c\u5982\u679c\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u6216\u672b\u7aef\u914d\u7f6e\u7279\u6b8a\uff0c\u5219\u5e94\u6309\u8bbe\u8ba1\u52a0\u88c5\u3002\u6240\u4ee5<b>\u8981\u4e0d\u8981\u6c34\u7bb1\uff0c\u770b\u7684\u662f\u7b97\u51fa\u6765\u7684\u6c34\u91cf\uff0c\u4e0d\u662f\u62a5\u4ef7\u5355\u4e0a\u7684\u60ef\u4f8b<\/b>\u3002<\/p>\n<\/div>\n\n<div class=\"lmss-pics2\">\n<figure class=\"lmss-pic\" style=\"margin:0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxdfsycxt-dhcsx-ylt.jpg\" alt=\"\u6c34\u5885\u9002FX\u5355\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u5e26\u7f13\u51b2\u6c34\u7bb1\u539f\u7406\u56fe \u00b7 \u7528\u4e8e\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u65f6\u7684\u8bbe\u8ba1\" width=\"1400\" height=\"900\" loading=\"lazy\">\n<figcaption>\u5e26\u7f13\u51b2\u6c34\u7bb1\u7684\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u65f6\u91c7\u7528\uff09<\/figcaption>\n<\/figure>\n<figure class=\"lmss-pic\" style=\"margin:0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sssfxsfsycxtylt.jpg\" alt=\"\u6c34\u5885\u9002FX\u53cc\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe \u00b7 \u5927\u6237\u578b\u6c34\u673a\u4e24\u8054\u4f9b\u7cfb\u7edf\u8bbe\u8ba1\" width=\"1400\" height=\"900\" loading=\"lazy\">\n<figcaption>\u53cc\u98ce\u6247\u4e00\u6b21\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u5927\u6237\u578b \/ \u522b\u5885\u9002\u7528\uff09<\/figcaption>\n<\/figure>\n<\/div>\n\n<h3 class=\"lmss-h3\">4.3 \u5de5\u5730\u5b9e\u62cd<\/h3>\n<p class=\"lmss-desc\">\u4e0b\u9762\u56db\u5f20\u6765\u81ea\u6210\u90fd\u53cc\u6d41\u533a\u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8\u53f6\u8001\u5e08\u5bb6\u7684\u6c34\u5885\u9002 FX \u4e24\u8054\u4f9b\u5de5\u5730\uff0c\u5747\u4e3a\u771f\u5b9e\u65bd\u5de5\u8282\u70b9\u7167\u7247\u3002<\/p>\n<div class=\"lmss-pics2\">\n<figure class=\"lmss-pic\" style=\"margin:0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/zjlxla-yls-njaz-01.jpg\" alt=\"\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u98ce\u673a\u76d8\u7ba1\u540a\u88c5\u5b9e\u62cd \u00b7 \u6210\u90fd\u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8\" width=\"900\" height=\"600\" loading=\"lazy\">\n<figcaption>\u98ce\u673a\u76d8\u7ba1\u540a\u88c5 \u00b7 \u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8<\/figcaption>\n<\/figure>\n<figure class=\"lmss-pic\" style=\"margin:0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/zjlxla-yls-glzg-01.jpg\" alt=\"\u6c34\u673a\u4e24\u8054\u4f9b\u4e3b\u7ba1\u8def\u5b89\u88c5\u5b9e\u62cd \u00b7 \u6210\u90fd\u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8\" width=\"900\" height=\"600\" loading=\"lazy\">\n<figcaption>\u4e3b\u7ba1\u8def\u5b89\u88c5 \u00b7 \u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8<\/figcaption>\n<\/figure>\n<figure class=\"lmss-pic\" style=\"margin:0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/zjlxla-yls-jsbps.jpg\" alt=\"\u5730\u6696\u6324\u5851\u677f\u94fa\u8bbe\u5b9e\u62cd \u00b7 \u6210\u90fd\u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8\" width=\"900\" height=\"600\" loading=\"lazy\">\n<figcaption>\u5730\u6696\u6324\u5851\u677f\u94fa\u8bbe \u00b7 \u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8<\/figcaption>\n<\/figure>\n<figure class=\"lmss-pic\" style=\"margin:0\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/zjlxla-yls-azhsj.jpg\" alt=\"\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u5b89\u88c5\u5b8c\u6210\u540e\u5b9e\u666f \u00b7 \u6210\u90fd\u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8\" width=\"900\" height=\"600\" loading=\"lazy\">\n<figcaption>\u5b89\u88c5\u5b8c\u6210\u5b9e\u666f \u00b7 \u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8<\/figcaption>\n<\/figure>\n<\/div>\n\n<h3 class=\"lmss-h3\">4.4 \u8d28\u4fdd\u4e0e\u8054\u4fdd<\/h3>\n<div class=\"lmss-grid3\">\n<div class=\"lmss-pain\"><b>\ud83d\udee1\ufe0f \u4e3b\u673a\u539f\u5382\u8d28\u4fdd<\/b><span>\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a\u6309\u5382\u5bb6\u653f\u7b56\u6267\u884c<\/span><\/div>\n<div class=\"lmss-pain\"><b>\ud83d\udd27 \u5b89\u88c5\u8d28\u4fdd<\/b><span>\u9f99\u8109\u6696\u901a\u5bf9\u5b89\u88c5\u5de5\u7a0b\u8d1f\u8d23\uff0c\u9690\u853d\u5de5\u7a0b\u8282\u70b9\u7559\u5b58\u9a8c\u6536\u5355<\/span><\/div>\n<div class=\"lmss-pain\"><b>\ud83d\udcc5 \u4f1a\u5458\u5ef6\u4fdd<\/b><span>\u4f1a\u5458\u53ef\u53e0\u52a0\u5ef6\u4fdd\u4e0e\u5e74\u5ea6\u7ef4\u62a4\u6743\u76ca\uff0c24 \u5c0f\u65f6\u5e94\u6025\u4e0a\u95e8<\/span><\/div>\n<\/div>\n\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\u2464<\/span>\u6848\u4f8b\u9a8c\u8bc1\uff1a\u6210\u90fd\u771f\u5b9e\u843d\u5730\u9879\u76ee<\/h2>\n<p class=\"lmss-desc\">\u4ef7\u683c\u4e4b\u5916\uff0c\u66f4\u8be5\u770b\u7684\u662f\"\u540c\u7c7b\u578b\u6237\u578b\u6709\u6ca1\u6709\u505a\u8fc7\"\u3002\u4ee5\u4e0b\u5747\u4e3a\u9f99\u8109\u6696\u901a\u6210\u90fd\u5df2\u5b8c\u5de5\u6216\u5df2\u4ea4\u4ed8\u7684\u771f\u5b9e\u9879\u76ee\uff0c\u53ef\u6309\u5c0f\u533a\u540d\u68c0\u7d22\u67e5\u770b\u5b8c\u6574\u65b9\u6848\u3002<\/p>\n\n<div class=\"lmss-chain\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=11713\">\u9f99\u6e56\u6e90\u8457\u4e1c\u533a 90\u33a1 \u5957\u4e09 \u00b7 \u6c64\u5148\u751f<span>RAS-160 \u5168\u53d8\u9891 + \u514d\u7f13\u51b2\u6c34\u7bb1\u4e00\u6b21\u7cfb\u7edf + 5 \u53f0\u96f6\u8d8a\u98ce\u76d8<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=11802\">\u4fdd\u5229\u5317\u65b0\u65f6\u5149 \u4e24\u5c42\u4f4f\u5b85 \u00b7 \u8d75\u5973\u58eb<span>\u6c34\u5885\u9002 FX 160 \u578b + 6 \u53f0\u96f6\u8d8a DC \u98ce\u76d8\uff0c\u7a7a\u8c03\u7ea6 123\u33a1<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=10861\">\u4e2d\u5efa\u9e7f\u6eaa\u6f9c\u5cb8 \u00b7 \u53f6\u8001\u5e08<span>\u6c34\u5885\u9002 FX \u4e24\u8054\u4f9b + \u745e\u7f8e\u70ed\u6c34\u5668\u7efc\u5408\u6848\u4f8b<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=12733\">\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547 \u81ea\u5efa\u623f<span>\u6c34\u5885\u9002 220 \u578b\uff08\u4e09\u76f8\u6da1\u65cb\uff09\u4e8c\u8054\u4f9b\u5b9e\u6d4b\u6848\u4f8b<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=14081\">\u5929\u5e9c\u58f9\u53f7 \u7ea6 114\u33a1 \u53cc\u5c42<span>\u6c34\u5885\u9002 180 \u578b\u4e24\u8054\u4f9b + \u5168\u5c4b\u65b0\u98ce<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=6746\">\u6c64\u5148\u751f \u00b7 \u6c34\u5885\u9002\u5168\u53d8\u9891\u4e24\u8054\u4f9b<span>\u5929\u6c34\u5730\u6c34\u7cfb\u7edf\uff0c\u542b\u5e26\u7f13\u51b2\u6c34\u7bb1\u65b9\u6848\u5bf9\u6bd4\u4e0e\u8d39\u7528\u6d4b\u7b97<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=11776\">\u661f\u66dc\u540d\u82d1 \u00b7 \u4f55\u5148\u751f<span>\u6c34\u673a FX160 \u4e0e\u5929\u6c1f\u5730\u6c34\u4e09\u7ba1\u5236\uff0c\u540c\u6237\u578b\u4e24\u5957\u914d\u7f6e\u6a2a\u5411\u5bf9\u6bd4<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=1991\">\u7965\u57df 4-1-804 \u6863\u6848<span>\u6c34\u5885\u9002 160 \u62d6\u4e94\uff0c140 \u5347 160 \u7684\u9009\u578b\u8fc7\u7a0b\u8bb0\u5f55<\/span><\/a>\n<\/div>\n\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\u2465<\/span>\u9ad8\u9891\u95ee\u7b54<\/h2>\n<div class=\"lmss-faq\">\n\n<details>\n<summary>\u6c34\u5885\u9002 FX \u7cfb\u5217\u548c VF \u7cfb\u5217\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/summary>\n<div class=\"lmss-ans\">\u4e24\u6761\u7ebf\u90fd\u5c5e\u65e5\u7acb\u6c34\u5885\u9002\u5168\u53d8\u9891\u6c34\u673a\uff0c\u4e0d\u662f\u8c01\u66ff\u4ee3\u8c01\u3002VF \u662f\u6574\u673a\u7248\uff1a\u8986\u76d6 80\uff5e180 \u578b\uff08\u5355\u76f8 220V\uff0c\u53cc\u8f6c\u5b50\uff09\u4e0e 200\uff5e500 \u578b\uff08\u4e09\u76f8 380V\uff0c\u8865\u6c14\u589e\u7113\u6da1\u65cb\uff09\uff0c\u4e3b\u673a\u5185\u7f6e\u53d8\u9891\u6c34\u6cf5\u4e0e\u81a8\u80c0\u7f50\uff0c\u51fa\u5382\u5c31\u628a\u6cf5\u7684\u81ea\u9002\u5e94\u63a7\u5236\u4e0e\u538b\u7f29\u673a\u3001\u5185\u5916\u673a\u8054\u52a8\u914d\u597d\u4e86\uff1bFX \u662f\u6cf5\u5916\u7f6e\u7248\uff1a\u5355\u76f8\u8986\u76d6 140\uff5e200 \u578b\uff08\u53cc\u8f6c\u5b50\uff09\u3001\u4e09\u76f8\u8986\u76d6 220\uff5e340 \u578b\uff08220 \u578b\u53ca\u4ee5\u4e0a\u6da1\u65cb\uff09\uff0c\u4e3b\u673a\u4e0d\u5e26\u6cf5\u4e0e\u7f50\u3002\u80fd\u6548\u7b49\u7ea7\u4e0e\u51fa\u6c34\u6e29\u5ea6\u533a\u95f4\u57fa\u672c\u4e00\u81f4\uff08\u5236\u70ed\u51fa\u6c34 25\uff5e55\u2103\u3001\u8fd0\u884c\u73af\u6e29 -30\uff5e28\u2103\uff09\uff0c\u5dee\u522b\u5728\u8986\u76d6\u6bb5\u4e0e\u6cf5\u7684\u4f4d\u7f6e\u3002\u6c34\u7cfb\u7edf\u7684\u96be\u70b9\u5c31\u5728\u6cf5\u7684\u9009\u578b\u3001\u8054\u52a8\u4e0e\u63a7\u5236\u2014\u2014\u65bd\u5de5\u65b9\u6c34\u7cfb\u7edf\u7ecf\u9a8c\u4e0d\u591f\u65f6\uff0c\u6211\u4eec\u5efa\u8bae\u9009 VF\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6210\u90fd\u6c34\u5885\u9002\u4e8c\u8054\u4f9b\u4e00\u62d6\u56db\u591a\u5c11\u94b1\uff1f<\/summary>\n<div class=\"lmss-ans\">\u6210\u90fd\u672c\u5730\"\u7a7a\u8c03+\u5730\u6696\u6574\u5957\"\u53c2\u8003\u533a\u95f4\u7ea6 \u00a564,900\uff5e81,799\uff0c\u53e3\u5f84\u4e3a\u542b\u5730\u6696\u56de\u586b\u627e\u5e73\u3001\u6bdb\u576f\u65b0\u623f\u65e0\u62c6\u6539\u3002\u771f\u5b9e\u6210\u4ea4\u951a\u70b9\u5982\u60a6\u84c9\u4e1c\u65b9 4-1-102\uff08140 \u578b\u4e3b\u673a\uff09\u00a564,900\u3001\u8a89\u6d6a\u4e1c\u671b\uff08160 \u578b\u4e3b\u673a\uff09\u7ea6 \u00a565,000\u3002\u533a\u95f4\u4e0b\u9650\u4e3a\u57fa\u7840\u914d\u7f6e\uff0c\u4e0a\u9650\u542b\u51c0\u5316\u578b\u5185\u673a\u4e0e\u96c6\u63a7\u5c4f\u8054\u52a8\u7b49\u5347\u7ea7\uff0c\u6700\u7ec8\u4ee5\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u5177\u7684\u6b63\u5f0f\u65b9\u6848\u4e3a\u51c6\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6c34\u5885\u9002\u4e00\u62d6\u4e94\u3001\u4e00\u62d6\u516d\u4ef7\u683c\u533a\u95f4\u662f\u591a\u5c11\uff1f<\/summary>\n<div class=\"lmss-ans\">\u4e00\u62d6\u4e94\u53c2\u8003\u7ea6 \u00a585,000\uff5e95,000\uff08\u951a\u70b9\uff1a\u4e2d\u6d77\u6d63\u4e91\u5c45 140 \u578b\u4e3b\u673a\u4e00\u62d6\u4e94 \u00a588,500\uff09\uff1b\u4e00\u62d6\u516d\u53c2\u8003\u7ea6 \u00a585,000\uff5e98,000\uff08\u951a\u70b9\uff1a\u4fdd\u5229\u5927\u56fd\u749f 160 \u578b \u00a591,156\u3001\u68e0\u6e56\u67cf\u6797\u57ce 180 \u578b\u5927\u6237\u578b \u00a598,000\uff09\u3002\u62d6\u6570\u8d8a\u5927\uff0c\u5916\u673a\u4e0e\u5185\u673a\u603b\u8d1f\u8377\u5339\u914d\u8d8a\u590d\u6742\uff0c\u5efa\u8bae\u9884\u7ea6\u4e0a\u95e8\u52d8\u6d4b\u62ff\u5230\u5b8c\u6574\u914d\u7f6e\u6e05\u5355\u518d\u5bf9\u6bd4\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6211\u5bb6\u53ea\u6709 220V \u5355\u76f8\u7535\uff0c\u80fd\u88c5\u6c34\u5885\u9002\u5417\uff1f<\/summary>\n<div class=\"lmss-ans\">\u53ef\u4ee5\u3002\u6c34\u5885\u9002 FX \u7cfb\u5217\u7684 140\uff5e200 \u578b\u3001VF \u7cfb\u5217\u7684 80\uff5e180 \u578b\u90fd\u662f\u5355\u76f8 220V \u673a\u578b\uff0c840mm \u8d85\u8584\u673a\u8eab\u53ef\u88c5\u98d8\u7a97\u4e0b\uff0c\u65e0\u9700\u4e09\u76f8\u7535\u589e\u5bb9\u3002\u5982\u679c\u9762\u79ef\u8d85\u8fc7 150\u33a1 \u6216\u672b\u7aef\u6570\u91cf\u591a\uff0c\u9700\u8981\u4e09\u76f8 380V \u7684\u5927\u5339\u6570\u673a\u578b\uff0c\u5219\u8981\u786e\u8ba4\u5165\u6237\u7535\u6e90\u6761\u4ef6\uff0c\u53ef\u5148\u4e0a\u95e8\u52d8\u6d4b\u8bc4\u4f30\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6c34\u5885\u9002\u9700\u8981\u914d\u7f13\u51b2\u6c34\u7bb1\u5417\uff1f<\/summary>\n<div class=\"lmss-ans\">\u770b\u7cfb\u7edf\u603b\u6c34\u91cf\uff0c\u4e0d\u770b\u60ef\u4f8b\u3002\u65e5\u7acb\u6c34\u5885\u9002\u5b98\u65b9\u6807\u51c6\u662f\u6240\u9700\u6c34\u5bb9\u91cf\u4e0b\u9650\uff1d\u4e3b\u673a\u540d\u4e49\u5236\u51b7\u91cf\uff08kW\uff09\u00d72\u3002\u4ee5\u6210\u90fd\u9f99\u6e56\u6e90\u8457\u4e1c\u533a\u6c64\u5148\u751f\u5bb6\u4e3a\u4f8b\uff0c\u4e3b\u673a RAS-160\uff08\u540d\u4e49\u5236\u51b7\u91cf\u7ea6 16kW\uff09\uff0c\u6807\u51c6\u53ea\u9700 32L\uff0c\u800c\u672c\u6848\u7cfb\u7edf\u603b\u6c34\u91cf\u7ea6 76L\uff0c\u8d85\u6807 2.4 \u500d\uff0c\u5b8c\u5168\u65e0\u9700\u7f13\u51b2\u6c34\u7bb1\u3002\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u65f6\u624d\u9700\u6309\u8bbe\u8ba1\u52a0\u88c5\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6c34\u5885\u9002\u6bd4\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u8d35\u591a\u5c11\uff0c\u8d35\u5728\u54ea\uff1f<\/summary>\n<div class=\"lmss-ans\">\u6c34\u673a\u6bd4\u540c\u9762\u79ef\u6c1f\u673a\u8d35\uff0c\u4e3b\u8981\u8d35\u5728\u4e00\u6574\u6761\u6c34\u8def\u7cfb\u7edf\u4e0e\u672b\u7aef\u5f62\u5f0f\uff1a\u591a\u51fa\u98ce\u673a\u76d8\u7ba1\u3001\u4e3b\u7ba1\u652f\u7ba1\u4e0e\u9600\u95e8\u914d\u4ef6\u3001\u6c34\u8def\u9009\u6750\u4e0e\u4fdd\u6e29\uff0c\u8fd8\u8981\u628a\u5730\u6696\u56de\u8def\u4e0e\u56de\u586b\u4e00\u5e76\u505a\u8fdb\u53bb\u3002\u5bf9\u5e94\u7684\u6536\u76ca\u662f\u51fa\u98ce 7\uff5e25\u2103\uff08\u8212\u9002\u533a 15\uff5e20\u2103\uff09\u63a5\u8fd1\u81ea\u7136\u98ce\u3001\u4e0d\u5e72\u71e5\u4e0d\u523a\u9aa8\uff0c\u4e14\u53ef\u5e73\u6ed1\u5347\u7ea7\u5168\u5c4b\u5168\u611f\u4e94\u6052\u3002\u662f\u5426\u503c\u5f97\uff0c\u53d6\u51b3\u4e8e\u5bf9\u9001\u98ce\u8212\u9002\u5ea6\u7684\u8981\u6c42\u4e0e\u957f\u671f\u81ea\u4f4f\u8ba1\u5212\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6c34\u5885\u9002\u53ef\u4ee5\u5347\u7ea7\u5168\u5c4b\u5168\u611f\u4e94\u6052\u5417\uff1f<\/summary>\n<div class=\"lmss-ans\">\u53ef\u4ee5\u3002\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u53ef\u53e0\u52a0 PE \u7eaf\u51c0\u751f\u6001\u51c0\u5316\u3001\u8054\u52a8\u9664\u6e7f\u65b0\u98ce\u3001\u52a0\u6e7f\u6a21\u5757\uff0c\u5347\u7ea7\u4e3a\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf\uff0c\u9020\u4ef7\u9ad8\u4e8e\u6807\u51c6\u4e24\u8054\u4f9b\u3002\u6210\u90fd\u5df2\u6709\u771f\u5b9e\u843d\u5730\u6848\u4f8b\uff08\u5982\u5929\u5e9c\u58f9\u53f7\u53cc\u5c42 114\u33a1 \u6c34\u5885\u9002\u4e24\u8054\u4f9b + \u5168\u5c4b\u65b0\u98ce\uff09\u3002\u5177\u4f53\u9884\u7b97\u9700\u6309\u6237\u578b\u4e0e\u6a21\u5757\u914d\u7f6e\u4e0a\u95e8\u6d4b\u7b97\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u6c34\u5885\u9002\u540e\u671f\u7ef4\u62a4\u9ebb\u70e6\u5417\uff1f\u8d28\u4fdd\u600e\u4e48\u7b97\uff1f<\/summary>\n<div class=\"lmss-ans\">\u4e0d\u9ebb\u70e6\u3002\u65e5\u5e38\u7ef4\u62a4\u4e3b\u8981\u662f\u5b9a\u671f\u6e05\u6d17\u98ce\u673a\u76d8\u7ba1\u6ee4\u7f51\u3001\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\uff1b\u82e5\u91c7\u7528\u514d\u7f13\u51b2\u6c34\u7bb1\u7684\u4e00\u6b21\u7cfb\u7edf\uff0c\u90e8\u4ef6\u66f4\u5c11\u3001\u6f5c\u5728\u6545\u969c\u70b9\u66f4\u5c11\u3002\u8d28\u4fdd\u4e3a\u4e09\u5c42\uff1a\u65e5\u7acb\u6c34\u5885\u9002\u4e3b\u673a\u539f\u5382\u8d28\u4fdd + \u9f99\u8109\u6696\u901a\u5b89\u88c5\u8d28\u4fdd + \u4f1a\u5458\u5ef6\u4fdd\uff0c\u5e76\u63d0\u4f9b 24 \u5c0f\u65f6\u5e94\u6025\u4e0a\u95e8\u3002<\/div>\n<\/details>\n\n<details>\n<summary>\u7f51\u4e0a\u6c34\u5885\u9002\u62a5\u4ef7\u53c2\u5dee\u4e0d\u9f50\uff0c\u600e\u4e48\u5206\u8fa8\uff1f<\/summary>\n<div class=\"lmss-ans\">\u770b\u6e05\u5355\u5199\u6ca1\u5199\u6e05\u4e94\u4ef6\u4e8b\uff1a\u2460 \u5916\u673a\u578b\u53f7\u5199\u5230\u5b57\u6bcd\uff08\u662f FPUEN2Q\/M \u8fd8\u662f\u522b\u7684\u6863\u4f4d\uff09\uff1b\u2461 \u98ce\u673a\u76d8\u7ba1\u53f0\u6570\u4e0e\u578b\u53f7\uff1b\u2462 \u6c34\u8def\u9009\u6750\u6309\u54ea\u4e2a\u6863\uff085 \u5339\/6 \u5339\/8 \u5339\u6863\u4f4d\u4e0d\u540c\uff09\uff1b\u2463 \u5730\u6696\u56de\u586b\u627e\u5e73\u662f\u5426\u542b\uff1b\u2464 \u5b89\u88c5\u662f\u5426\u5168\u5305\u3001\u5916\u673a\u540a\u88c5\u4e0e\u7535\u6e90\u7ebf\u662f\u5426\u53e6\u8ba1\u3002\u53ea\u62a5\u8bbe\u5907\u4ef7\u3001\u4e0d\u542b\u5b89\u88c5\u4e0e\u5730\u6696\u7684\u4f4e\u4ef7\u5355\uff0c\u8f83\u5bb9\u6613\u5728\u8fdb\u573a\u540e\u589e\u9879\u3002<\/div>\n<\/details>\n\n<\/div>\n\n<h2 class=\"lmss-h2\"><span class=\"lmss-num\">\ud83d\udd17<\/span>\u76f8\u5173\u5ef6\u4f38\u9605\u8bfb<\/h2>\n<div class=\"lmss-chain\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=10975\">\u6210\u90fd\u65e5\u7acb\u4e24\u8054\u4f9b\u4ef7\u683c<span>\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u3001\u6c34\u5885\u9002\u9884\u7b97\u603b\u5165\u53e3<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13151\">\u65e5\u7acb\u6c34\u5885\u9002\u6548\u679c\u4e0e\u80fd\u8017\u5b9e\u6d4b<span>\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u5b9e\u9645\u8fd0\u884c\u6570\u636e<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<span>\u6c34\u673a\u539f\u7406\u3001\u9009\u578b\u4e0e\u5b89\u88c5\u9a8c\u6536<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=12672\">\u6c34\u673a\u4e8c\u8054\u4f9b\u600e\u4e48\u9009<span>\u5bb6\u7528\u6c34\u673a\u4e8c\u8054\u4f9b\u9009\u8d2d\u903b\u8f91<\/span><\/a>\n<a href=\"https:\/\/www.longmai-nt.com\/?page_id=15911\">\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1f\u56db\u672c\u8d26\u62c6\u5f00\u7b97\u2014\u2014\u4ef7\u683c\u4e4b\u5916\u7684\u4e03\u9879\u914d\u7f6e\u5dee\u4ef7<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=1233\">\u65e5\u7acb\u6c34\u5885\u9002\u7cfb\u7edf\u4e13\u9898<span>FX \/ VF \u53c2\u6570\u3001\u5185\u673a\u4e0e\u914d\u4ef6\u9009\u578b<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u6210\u90fd\u6c34\u673a vs \u6c1f\u673a<span>\u5929\u6c34\u5730\u6c34\u3001\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u600e\u4e48\u9009<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13419\">\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009\uff5c\u4e00\u5f20\u8868\u770b\u61c2<span>\u6c1f\u673a\u3001\u6c34\u673a\u3001\u4e24\u8054\u4f9b\u4e0e\u4e94\u6052\u5bf9\u6bd4<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13115\">\u4ec0\u4e48\u662f\u4e8c\u8054\u4f9b\uff1f<span>\u4e00\u5957\u7cfb\u7edf\uff0c\u590f\u5929\u5236\u51b7\u3001\u51ac\u5929\u5730\u6696<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=10970\">\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4ef7\u683c<span>\u8212\u4eab \/ VAMmini\u2161 \/ \u5c0a\u777f\u5168\u7cfb\u5217\u9884\u7b97<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=10977\">\u6210\u90fd\u5730\u6696\u591a\u5c11\u94b1<span>\u4f1f\u661f\u5730\u6696\u7ba1\u6e05\u6c34 \/ \u7cbe\u88c5\u53c2\u8003\u5355\u4ef7<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=4556\">\u5730\u6696\u7cfb\u7edf\u62a5\u4ef7\u8ba1\u7b97\u5668<span>\u8f93\u5165\u6237\u578b\u5feb\u901f\u4f30\u7b97\u5730\u6696\u90e8\u5206\u9884\u7b97<\/span><\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=5849\">\u6696\u901a\u89e3\u51b3\u65b9\u6848\u805a\u5408<span>\u4e2d\u592e\u7a7a\u8c03\u3001\u4e24\u8054\u4f9b\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u51c0\u6c34\u5ba2\u6237\u65b9\u6848\u7d22\u5f15<\/span><\/a>\n<\/div>\n\n<div class=\"lmss-end\">\n<b>\ud83d\udcde \u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u54a8\u8be2 \u00b7 \u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/b>\n\u514d\u8d39\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b \/ \u6838\u5bf9\u578b\u53f7 \/ \u6c34\u673a\u4e24\u8054\u4f9b\u65b9\u6848\u8bbe\u8ba1\u4e0e\u62a5\u4ef7\n<span class=\"lmss-phone\">028-86131795\uff08\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff09<\/span>\n<span class=\"lmss-phone\" style=\"font-size:16px\">028-65272586\uff08\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff09<\/span>\n<b>\u9884\u7ea6\u52d8\u6d4b\u53ef\u83b7\u5f97\uff1a<\/b>\u2460 \u623f\u5c4b\u51b7\u70ed\u8d1f\u8377\u4e13\u4e1a\u6d4b\u7b97\uff08\u7a7a\u8c03 + \u5730\u6696\u540c\u6b65\uff09\uff1b\u2461 2\uff5e3 \u5957\u6c34\u5885\u9002\u914d\u7f6e\u6e05\u5355\u4e0e\u5bf9\u5e94\u9884\u7b97\uff1b\u2462 \u73b0\u573a\u8bc4\u4f30\u5916\u673a\u4f4d\u3001\u7535\u6e90\u6761\u4ef6\u4e0e\u5730\u6696\u56de\u586b\u6761\u4ef6\uff0c\u8bc6\u522b\u540e\u671f\u589e\u9879\u98ce\u9669\u3002\u52d8\u6d4b\u65e0\u6536\u8d39\uff0c\u65e0\u5f3a\u5236\u7b7e\u7ea6\u3002\n<\/div>\n\n<div class=\"lmss-store\">\n<div><b>\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97\uff09<\/b>\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7 \u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<br>\u70ed\u7ebf <em>028-86131795<\/em><\/div>\n<div><b>\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\uff08\u6210\u534e\u533a\u5e97\uff09<\/b>\u6210\u90fd\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<br>\u70ed\u7ebf <em>028-65272586<\/em><\/div>\n<\/div>\n\n<p class=\"lmss-foot\">\u514d\u8d23\u8bf4\u660e\uff1a\u672c\u9875\u4ef7\u683c\u4e3a\u6210\u90fd\u5730\u533a\u771f\u5b9e\u6210\u4ea4\u8bb0\u5f55\u6574\u7406\uff0c\u4ec5\u4f5c\u524d\u671f\u9009\u578b\u9884\u7b97\u53c2\u8003\uff0c\u4e0d\u4f5c\u4e3a\u5408\u540c\u62a5\u4ef7\uff1b\u8bbe\u5907\u9009\u914d\u3001\u623f\u5c4b\u5de5\u51b5\u3001\u65bd\u5de5\u6761\u4ef6\u5747\u4f1a\u9020\u6210\u6d6e\u52a8\u3002\u4e00\u5207\u4ee5\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u8f93\u51fa\u7684\u6b63\u5f0f\u65b9\u6848\u4e3a\u51c6\u3002\u6c34\u5885\u9002 FX \/ VF \u7cfb\u5217\u673a\u578b\u53c2\u6570\u4f9d\u636e\u65e5\u7acb\u5b98\u65b9\u4ea7\u54c1\u8d44\u6599\uff0c\u5177\u4f53\u4f9b\u8d27\u578b\u53f7\u4e0e\u914d\u7f6e\u4ee5\u5408\u540c\u786e\u8ba4\u4e3a\u51c6\u3002<\/p>\n\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\ud83d\udcd0 GEO \u4e94\u6b65\u6cd5 \u00b7 \u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1233,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-14764","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff1aFX \u4e0e VF \u5168\u7cfb\u5217\u673a\u578b\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u4e0e\u53c2\u8003\u96f6\u552e\u4ef7\u4e00\u6b21\u5217\u5168\uff0c\u5e76\u7ed9\u51fa\u6210\u90fd\u7a7a\u8c03\u52a0\u5730\u6696\u6574\u5957\u7684\u6210\u4ea4\u533a\u95f4\uff08\u4e00\u62d6\u56db\u3001\u4e94\u3001\u516d\uff09\u3002\u8bb2\u6e05 VF \u6574\u673a\u7248\u4e0e FX \u6cf5\u5916\u7f6e\u7248\u7684\u914d\u7f6e\u5dee\u522b\u4e0e\u63a8\u8350\u903b\u8f91\uff0c\u9009\u578b\u6309\u5bb6\u91cc\u7684\u7535\u6e90\u6761\u4ef6\u4e0e\u9762\u79ef\u5bf9\u53f7\u5165\u5ea7\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=14764\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff1aFX \u4e0e VF \u5168\u7cfb\u5217\u673a\u578b\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u4e0e\u53c2\u8003\u96f6\u552e\u4ef7\u4e00\u6b21\u5217\u5168\uff0c\u5e76\u7ed9\u51fa\u6210\u90fd\u7a7a\u8c03\u52a0\u5730\u6696\u6574\u5957\u7684\u6210\u4ea4\u533a\u95f4\uff08\u4e00\u62d6\u56db\u3001\u4e94\u3001\u516d\uff09\u3002\u8bb2\u6e05 VF \u6574\u673a\u7248\u4e0e FX \u6cf5\u5916\u7f6e\u7248\u7684\u914d\u7f6e\u5dee\u522b\u4e0e\u63a8\u8350\u903b\u8f91\uff0c\u9009\u578b\u6309\u5bb6\u91cc\u7684\u7535\u6e90\u6761\u4ef6\u4e0e\u9762\u79ef\u5bf9\u53f7\u5165\u5ea7\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=14764\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-25T17:41:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764\",\"name\":\"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \\\/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-sjkdsgpmt.jpg\",\"datePublished\":\"2026-10-12T18:05:16+00:00\",\"dateModified\":\"2026-10-25T17:41:48+00:00\",\"description\":\"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff1aFX \u4e0e VF \u5168\u7cfb\u5217\u673a\u578b\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u4e0e\u53c2\u8003\u96f6\u552e\u4ef7\u4e00\u6b21\u5217\u5168\uff0c\u5e76\u7ed9\u51fa\u6210\u90fd\u7a7a\u8c03\u52a0\u5730\u6696\u6574\u5957\u7684\u6210\u4ea4\u533a\u95f4\uff08\u4e00\u62d6\u56db\u3001\u4e94\u3001\u516d\uff09\u3002\u8bb2\u6e05 VF \u6574\u673a\u7248\u4e0e FX \u6cf5\u5916\u7f6e\u7248\u7684\u914d\u7f6e\u5dee\u522b\u4e0e\u63a8\u8350\u903b\u8f91\uff0c\u9009\u578b\u6309\u5bb6\u91cc\u7684\u7535\u6e90\u6761\u4ef6\u4e0e\u9762\u79ef\u5bf9\u53f7\u5165\u5ea7\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-sjkdsgpmt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-sjkdsgpmt.jpg\",\"width\":1754,\"height\":1240},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14764#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=13098\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u00b7 \u667a\u5885\u5168\u611f\u4e94\u6052\u7cfb\u7edf\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1233\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \\\/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff1aFX \u4e0e VF \u5168\u7cfb\u5217\u673a\u578b\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u4e0e\u53c2\u8003\u96f6\u552e\u4ef7\u4e00\u6b21\u5217\u5168\uff0c\u5e76\u7ed9\u51fa\u6210\u90fd\u7a7a\u8c03\u52a0\u5730\u6696\u6574\u5957\u7684\u6210\u4ea4\u533a\u95f4\uff08\u4e00\u62d6\u56db\u3001\u4e94\u3001\u516d\uff09\u3002\u8bb2\u6e05 VF \u6574\u673a\u7248\u4e0e FX \u6cf5\u5916\u7f6e\u7248\u7684\u914d\u7f6e\u5dee\u522b\u4e0e\u63a8\u8350\u903b\u8f91\uff0c\u9009\u578b\u6309\u5bb6\u91cc\u7684\u7535\u6e90\u6761\u4ef6\u4e0e\u9762\u79ef\u5bf9\u53f7\u5165\u5ea7\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=14764","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff1aFX \u4e0e VF \u5168\u7cfb\u5217\u673a\u578b\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u4e0e\u53c2\u8003\u96f6\u552e\u4ef7\u4e00\u6b21\u5217\u5168\uff0c\u5e76\u7ed9\u51fa\u6210\u90fd\u7a7a\u8c03\u52a0\u5730\u6696\u6574\u5957\u7684\u6210\u4ea4\u533a\u95f4\uff08\u4e00\u62d6\u56db\u3001\u4e94\u3001\u516d\uff09\u3002\u8bb2\u6e05 VF \u6574\u673a\u7248\u4e0e FX \u6cf5\u5916\u7f6e\u7248\u7684\u914d\u7f6e\u5dee\u522b\u4e0e\u63a8\u8350\u903b\u8f91\uff0c\u9009\u578b\u6309\u5bb6\u91cc\u7684\u7535\u6e90\u6761\u4ef6\u4e0e\u9762\u79ef\u5bf9\u53f7\u5165\u5ea7\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=14764","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-25T17:41:48+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=14764","url":"https:\/\/longmai-nt.com\/?page_id=14764","name":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=14764#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=14764#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg","datePublished":"2026-10-12T18:05:16+00:00","dateModified":"2026-10-25T17:41:48+00:00","description":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff1aFX \u4e0e VF \u5168\u7cfb\u5217\u673a\u578b\u3001\u7535\u6e90\u5f62\u5f0f\u3001\u5236\u51b7\u5236\u70ed\u91cf\u4e0e\u53c2\u8003\u96f6\u552e\u4ef7\u4e00\u6b21\u5217\u5168\uff0c\u5e76\u7ed9\u51fa\u6210\u90fd\u7a7a\u8c03\u52a0\u5730\u6696\u6574\u5957\u7684\u6210\u4ea4\u533a\u95f4\uff08\u4e00\u62d6\u56db\u3001\u4e94\u3001\u516d\uff09\u3002\u8bb2\u6e05 VF \u6574\u673a\u7248\u4e0e FX \u6cf5\u5916\u7f6e\u7248\u7684\u914d\u7f6e\u5dee\u522b\u4e0e\u63a8\u8350\u903b\u8f91\uff0c\u9009\u578b\u6309\u5bb6\u91cc\u7684\u7535\u6e90\u6761\u4ef6\u4e0e\u9762\u79ef\u5bf9\u53f7\u5165\u5ea7\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=14764#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=14764"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=14764#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-sjkdsgpmt.jpg","width":1754,"height":1240},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=14764#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c","item":"https:\/\/longmai-nt.com\/?page_id=671"},{"@type":"ListItem","position":3,"name":"\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66","item":"https:\/\/longmai-nt.com\/?page_id=13098"},{"@type":"ListItem","position":4,"name":"\u65e5\u7acb\u6c34\u5885\u9002\u4e24\u8054\u4f9b \u00b7 \u667a\u5885\u5168\u611f\u4e94\u6052\u7cfb\u7edf","item":"https:\/\/longmai-nt.com\/?page_id=1233"},{"@type":"ListItem","position":5,"name":"\u6210\u90fd\u65e5\u7acb\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u4ef7\u683c\uff5cFX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14764"}],"version-history":[{"count":11,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14764\/revisions"}],"predecessor-version":[{"id":16609,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14764\/revisions\/16609"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1233"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}