{"id":14964,"date":"2026-10-14T16:00:11","date_gmt":"2026-10-14T08:00:11","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=14964"},"modified":"2026-10-15T17:23:58","modified_gmt":"2026-10-15T09:23:58","slug":"%e4%b8%a4%e8%81%94%e4%be%9b%e5%94%ae%e5%90%8e%e7%99%bd%e7%9a%ae%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=14964","title":{"rendered":"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1"},"content":{"rendered":"\n<section class=\"lmwp\">\n<style>\n.lmwp{font-family:-apple-system,BlinkMacSystemFont,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#1f2937;line-height:1.78;max-width:900px;margin:0 auto;padding:18px 20px 40px;}\n.lmwp h1{font-size:27px;line-height:1.35;margin:0 0 14px;color:#0f172a;font-weight:800;}\n.lmwp h2{font-size:21px;margin:34px 0 12px;padding-left:12px;border-left:5px solid #0ea5e9;color:#0f172a;}\n.lmwp h3{font-size:17px;margin:22px 0 8px;color:#111827;}\n.lmwp p{margin:10px 0;}\n.lmwp a{color:#0369a1;text-decoration:none;border-bottom:1px solid rgba(3,105,161,.35);}\n.lmwp a:hover{color:#075985;}\n.lmwp table{border-collapse:collapse;width:100%;margin:14px 0;font-size:14px;}\n.lmwp th,.lmwp td{border:1px solid #e5e7eb;padding:9px 11px;vertical-align:top;}\n.lmwp th{background:#f1f5f9;color:#0f172a;font-weight:700;text-align:left;}\n.lmwp tbody tr:nth-child(even){background:#fafafa;}\n.lmwp .lm-lead{background:#f0f9ff;border:1px solid #bae6fd;border-radius:10px;padding:16px 18px;font-size:15px;margin:16px 0;}\n.lmwp .lm-callout{background:#f0f9ff;border:1px solid #bae6fd;border-radius:10px;padding:14px 18px;margin:14px 0;font-size:14px;}\n.lmwp .lm-warn{background:#fef2f2;border:1px solid #fecaca;border-radius:10px;padding:14px 18px;margin:14px 0;font-size:14px;}\n.lmwp .lm-btn{display:inline-block;background:#0ea5e9;color:#fff!important;border:none;border-radius:8px;padding:11px 20px;font-weight:700;font-size:15px;margin:6px 8px 6px 0;}\n.lmwp .lm-btn:hover{background:#0284c7;}\n.lmwp .lm-stores{display:flex;flex-wrap:wrap;gap:14px;margin:14px 0;}\n.lmwp .lm-store{flex:1 1 280px;display:flex;flex-direction:column;background:#f8fafc;border:1px solid #e2e8f0;border-radius:10px;padding:14px 16px;font-size:14px;}\n.lmwp .lm-store img{width:100%;margin-top:auto;border-radius:8px;border:1px solid #e2e8f0;display:block;}\n.lmwp .lm-store b{color:#0f172a;}\n.lmwp .lm-faq details{border:1px solid #e5e7eb;border-radius:8px;padding:0 14px;margin:10px 0;background:#fff;}\n.lmwp .lm-faq summary{cursor:pointer;font-weight:700;padding:12px 0;color:#0f172a;list-style:none;}\n.lmwp .lm-faq summary::-webkit-details-marker{display:none;}\n.lmwp .lm-faq details p{margin:4px 0 14px;font-size:14.5px;}\n.lmwp ul{margin:10px 0;padding-left:22px;}\n.lmwp li{margin:5px 0;}\n.lmwp .lm-ref{background:#f8fafc;border-left:4px solid #cbd5e1;padding:10px 14px;margin:12px 0;font-size:13.5px;color:#475569;}\n<\/style>\n\n<p class=\"lm-lead\">\u5f88\u591a\u4eba\u628a\u4e24\u8054\u4f9b\u7406\u89e3\u6210\"\u4e00\u53f0\u4e3b\u673a\u52a0\u51e0\u6839\u7ba1\u5b50\"\uff0c\u4f46\u8fd9\u662f\u4e2a\u6839\u672c\u6027\u7684\u8bef\u4f1a\u3002<b>\u4e24\u8054\u4f9b\u662f\u4e00\u5957\u5b8c\u6574\u7684\u7cfb\u7edf<\/b>\uff1a\u70ed\u6e90\u8d1f\u8d23\u4ea7\u51b7\u4ea7\u70ed\uff0c\u8f93\u914d\u8d1f\u8d23\u628a\u80fd\u91cf\u9001\u5230\u6bcf\u4e2a\u623f\u95f4\uff0c\u672b\u7aef\u8d1f\u8d23\u628a\u70ed\u91cf\u5747\u5300\u653e\u51fa\u6765\uff0c\u63a7\u5236\u51b3\u5b9a\u4ec0\u4e48\u65f6\u5019\u70e7\u3001\u70e7\u591a\u5c11\u3001\u7ed9\u54ea\u91cc\u3002\u56db\u4e2a\u73af\u8282\u7f3a\u4e00\u4e0d\u53ef\u3002<br><br>\u66f4\u5173\u952e\u7684\u662f\uff1a<b>\u4e24\u8054\u4f9b\u7684\u6bdb\u75c5\uff0c\u516b\u6210\u4e0d\u51fa\u5728\u4e3b\u673a\u4e0a\uff0c\u800c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u4e0a\u3002<\/b>\u8fd9\u4e00\u9875\u628a\"\u4e3a\u4ec0\u4e48\"\u548c\"\u600e\u4e48\u529e\"\u4e00\u8d77\u8bb2\u6e05\u695a\u2014\u2014\u524d\u534a\u8bb2\u539f\u7406\u548c\u8bbe\u8ba1\uff0c\u540e\u534a\u8bb2\u6545\u969c\u3001\u4fdd\u517b\u548c\u600e\u4e48\u9632\u3002<br><br><b>\u5173\u4e8e\u672c\u9875\uff1a<\/b>\u4e0d\u63a8\u9500\u4ea7\u54c1\uff0c\u53ea\u8bb2\u539f\u7406\u548c\u5ba2\u89c2\u89c4\u5f8b\u3002\u7ed3\u8bba\u5c3d\u53ef\u80fd\u5f15\u7528\u53ef\u67e5\u8bc1\u7684\u56fd\u5bb6\u6807\u51c6\u3001\u5b9e\u6d4b\u6570\u636e\u548c\u5de5\u7a0b\u5b9e\u8df5\uff0c\u4f60\u90fd\u53ef\u4ee5\u81ea\u5df1\u590d\u7b97\u3001\u6838\u9a8c\u3002<\/p>\n\n<h2>\u4e00\u3001\u4e24\u8054\u4f9b\u662f\u4ec0\u4e48\uff1a\u4e00\u5957\u7cfb\u7edf\uff0c\u4e0d\u662f\u4e00\u53f0\u673a\u5668<\/h2>\n<p>\u4e24\u8054\u4f9b\uff0c\u5c31\u662f\"\u5236\u51b7 + \u5236\u70ed\"\u7531\u540c\u4e00\u5957\u8bbe\u5907\u89e3\u51b3\u3002\u5e02\u573a\u4e0a\u4e5f\u6709\u4eba\u53eb\u5b83\"\u4e8c\u8054\u4f9b\"\uff0c\u8bf4\u7684\u662f\u540c\u4e00\u4ef6\u4e8b\uff0c\u4e24\u79cd\u53eb\u6cd5\u90fd\u5e38\u89c1\uff0c\u672c\u9875\u4e24\u4e2a\u8bcd\u90fd\u5728\u7528\uff1a<\/p>\n<ul>\n<li><b>\u590f\u5929<\/b>\uff1a\u4e3b\u673a\u4ea7\u4f4e\u6e29\u51b7\u6c34\uff0c\u9001\u5230\u5404\u623f\u95f4\u7684\u98ce\u673a\u76d8\u7ba1\uff0c\u5439\u51fa\u67d4\u548c\u7684\u51c9\u98ce\uff1b<\/li>\n<li><b>\u51ac\u5929<\/b>\uff1a\u4e3b\u673a\u4ea7\u70ed\u6c34\uff0c\u9001\u5230\u57cb\u5728\u5730\u4e0b\u7684\u5730\u6696\u76d8\u7ba1\uff0c\u4ece\u811a\u5e95\u6696\u4e0a\u6765\u3002<\/li>\n<\/ul>\n<p>\u6309\u5ba4\u5185\u4fa7\u7684\u4f20\u70ed\u4ecb\u8d28\uff0c\u5206\u4e24\u6761\u6280\u672f\u8def\u7ebf\uff1a<\/p>\n<table>\n<thead><tr><th>\u8def\u7ebf<\/th><th>\u5236\u51b7\u4fa7<\/th><th>\u5236\u70ed\u4fa7<\/th><th>\u7279\u70b9<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><b>\u5929\u6c34\u5730\u6c34<\/b><\/td><td>\u6c34<\/td><td>\u6c34<\/td><td>\u51fa\u98ce\u67d4\u548c\u4e0d\u5e72\u71e5\uff1b\u5236\u70ed\u5747\u5300\u3001\u672b\u7aef\u6269\u5c55\u6027\u5f3a\uff08\u65e5\u7acb\u6c34\u5885\u9002 VF \u5373\u6b64\u8def\u7ebf\uff09<\/td><\/tr>\n<tr><td><b>\u5929\u6c1f\u5730\u6c34<\/b><\/td><td>\u5236\u51b7\u5242\u76f4\u51b7<\/td><td>\u6c34\uff08\u7ecf\u6c34\u6a21\u5757\u6362\u70ed\uff09<\/td><td>\u5236\u51b7\u54cd\u5e94\u5feb\u3001\u9664\u6e7f\u5f3a\uff08\u5982 VAM \u5c0a\u777f\u5916\u63a5\u6c34\u6a21\u5757\u65b9\u6848\uff09<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u4e24\u6761\u8def\u7ebf\u672c\u8d28\u76f8\u540c\u2014\u2014\u90fd\u662f\u4e00\u53f0\u4e3b\u673a\u52a0\u4e00\u4e2a\u6362\u70ed\u5668\uff0c\"\u51fa\u6c34\u53c8\u5165\u5730\"\uff1b\u533a\u522b\u53ea\u5728\u6362\u70ed\u5668\u653e\u5728\u54ea\u3001\u7528\u4ec0\u4e48\u4ecb\u8d28\u3002\u6240\u4ee5\u522b\u4e00\u542c\u540d\u5b57\u5c31\u4ee5\u4e3a\u5dee\u5f97\u8fdc\u3002\u4e24\u8005\u7684\u5173\u7cfb\u548c\u9009\u6cd5\uff0c\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13115\">\u4ec0\u4e48\u662f\u4e8c\u8054\u4f9b<\/a> \u548c <a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u4e8c\u8054\u4f9b\u600e\u4e48\u9009\uff08\u6c34\u673a vs \u6c1f\u673a\uff09<\/a>\u3002\u8981\u6df1\u62a0\u539f\u7406\u3001\u67b6\u6784\u4e0e\u6750\u6599\u9009\u578b\uff0c\u8bfb <a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66<\/a>\u3002<\/p>\n\n<h2>\u4e8c\u3001\u5b83\u4e3a\u4ec0\u4e48\u7701\uff1a\u7a7a\u6c14\u80fd\u662f\"\u642c\u8fd0\u70ed\u91cf\"\uff0c\u4e0d\u662f\"\u5236\u9020\u70ed\u91cf\"<\/h2>\n<p>\u4e24\u8054\u4f9b\u8282\u80fd\u7684\u6839\u672c\uff0c\u5728\u4e8e\u4e3b\u673a\u662f<b>\u7a7a\u6c14\u6e90\u70ed\u6cf5<\/b>\uff0c\u4e0d\u662f\u7535\u52a0\u70ed\u3001\u4e5f\u4e0d\u662f\u71c3\u6c14\u71c3\u70e7\u3002\u70ed\u6cf5\u505a\u7684\u662f\"\u642c\u8fd0\"\u800c\u4e0d\u662f\"\u5236\u9020\"\uff1a<\/p>\n<ul>\n<li>\u51ac\u5929\uff0c\u5b83\u4ece\u5ba4\u5916\u7a7a\u6c14\u91cc\u5438\u6536\u4f4e\u4f4d\u70ed\u80fd\uff0c\u9760\u538b\u7f29\u673a\u505a\u529f\u628a\u6e29\u5ea6\u63d0\u4e0a\u6765\uff0c\u9001\u8fdb\u5c4b\u91cc\uff1b<\/li>\n<li>\u5236\u70ed\u80fd\u6548\u6bd4\uff08COP\uff09\u901a\u5e38\u53ef\u8fbe 3 \u4ee5\u4e0a\u2014\u2014<b>\u6d88\u8017 1 \u5ea6\u7535\uff0c\u642c\u6765 3 \u5ea6\u4ee5\u4e0a\u7684\u70ed\u91cf<\/b>\u3002<\/li>\n<\/ul>\n<div class=\"lm-callout\"><b>\u6253\u4e2a\u6bd4\u65b9\uff1a<\/b>\u7535\u52a0\u70ed\u50cf\"\u7528\u94b1\u4e70\u70ed\"\uff0c1 \u5757\u94b1\u4e70 1 \u4efd\uff1b\u70ed\u6cf5\u50cf\"\u7528 1 \u5757\u94b1\u96c7\u4eba\u628a\u514d\u8d39\u7684\u70ed\u642c\u8fdb\u6765\"\uff0c\u80fd\u642c\u56de 3 \u4efd\u3002\u8fd9\u5c31\u662f\u5b83\u6bd4\u71c3\u6c14\u91c7\u6696\u7701\u7684\u6839\u672c\u539f\u56e0\u3002<\/div>\n\n<h2>\u4e09\u3001\u8bbe\u8ba1\u89c4\u8303\uff1a\u4e00\u5207\u95ee\u9898\u7684\u6839\u5b50\u5728\u8fd9\u91cc<\/h2>\n<h3>\u4e24\u8054\u4f9b\u4e0e\u5730\u6696\u8bbe\u8ba1\uff0c\u6709\u660e\u786e\u7684\u56fd\u5bb6\u6807\u51c6\u548c\u89c4\u7a0b\u7ea6\u675f<\/h3>\n<table>\n<thead><tr><th>\u6807\u51c6\u7f16\u53f7<\/th><th>\u6807\u51c6\u540d\u79f0<\/th><th>\u7ba1\u4ec0\u4e48<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>GB 50736-2012<\/td><td>\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><td>\u70ed\u8d1f\u8377\u9010\u9879\u8ba1\u7b97\u3001\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea6<\/td><\/tr>\n<tr><td>JGJ 142-2012<\/td><td>\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td><td>\u76d8\u7ba1\u95f4\u8ddd\/\u957f\u5ea6\/\u6c34\u6e29\/\u538b\u529b\u3001\u5730\u9762\u6e29\u5ea6<\/td><\/tr>\n<tr><td>GB 50242-2002<\/td><td>\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303<\/td><td>\u6253\u538b\u9a8c\u6536\u6807\u51c6<\/td><\/tr>\n<tr><td>DIN 4726<\/td><td>\u5851\u6599\u7ba1\u9053\u963b\u6c27\u6027\u80fd\u6807\u51c6<\/td><td>40\u2103 \u6c34\u6e29\u4e0b\uff0c\u6c27\u6e17\u900f\u7387\u5e94 \u2264 0.1 g\/(m\u00b3\u00b7d)<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h3>\"\u8bbe\u8ba1\u8d1f\u8377\"\u548c\"\u80fd\u8017\u8d1f\u8377\"\uff0c\u662f\u4e24\u4e2a\u6570\uff0c\u4e0d\u80fd\u6df7\u7528<\/h3>\n<p>\u8fd9\u662f\u884c\u4e1a\u91cc\u6700\u5e38\u88ab\u6df7\u6dc6\u3001\u4e5f\u6700\u5bb9\u6613\u88ab\u62ff\u6765\u5ffd\u60a0\u4e1a\u4e3b\u7684\u4e00\u5bf9\u6982\u5ff5\uff1a<\/p>\n<table>\n<thead><tr><th>\u5bf9\u6bd4\u9879<\/th><th>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/th><th>\u80fd\u8017\u70ed\u8d1f\u8377<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u662f\u4ec0\u4e48<\/td><td>\u6ee1\u8db3\u6700\u51b7\u90a3\u51e0\u5929\u7684\u9700\u6c42<\/td><td>\u6574\u4e2a\u91c7\u6696\u5b63\u7684\u5e73\u5747\u8fd0\u884c\u8d1f\u8377<\/td><\/tr>\n<tr><td>\u5927\u81f4\u6570\u503c<\/td><td>80\u2013220 W\/\u33a1\uff08\u770b\u5efa\u7b51\u7c7b\u578b\uff09<\/td><td>\u7ea6 50 W\/\u33a1\uff08\u6210\u90fd\u8282\u80fd\u5efa\u7b51\uff09<\/td><\/tr>\n<tr><td>\u7528\u6765\u5e72\u561b<\/td><td><b>\u9009\u4e3b\u673a<\/b>\uff0c\u4fdd\u8bc1\u6781\u7aef\u5929\u591f\u7528<\/td><td><b>\u7b97\u8fd0\u884c\u8d39<\/b><\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u4e00\u53e5\u8bdd\u8bb0\u4f4f\uff1a<b>\u914d\u4e3b\u673a\u6309\u8bbe\u8ba1\u8d1f\u8377\uff0c\u7b97\u8d39\u7528\u6309\u80fd\u8017\u8d1f\u8377<\/b>\u3002\u7528\u6708\u5747\u503c\u53bb\u914d\u4e3b\u673a\u4f1a\u9009\u5c0f\uff08\u6781\u7aef\u5929\u4e0d\u591f\u7528\uff09\uff0c\u7528\u5cf0\u503c\u53bb\u7b97\u6708\u8d39\u4f1a\u5413\u8dd1\u4eba\uff08\u5b9e\u9645\u8fdc\u4f4e\u4e8e\u6b64\uff09\u3002\u8fd9\u4e24\u4e2a\u6570\u90fd\u5bf9\uff0c\u7528\u9014\u4e0d\u540c\u3002\u7c7b\u6bd4\uff1a\u8f66\u80fd\u5f00 200 \u7801\uff08\u914d\u578b\uff09\uff0c\u5e02\u533a\u5e73\u5747\u53ea\u5f00 40 \u7801\uff08\u7b97\u6cb9\u8d39\uff09\u3002<\/p>\n<p>\u6210\u90fd\u8282\u80fd\u5efa\u7b51\u7684\u9010\u65f6\u52a8\u6001\u8ba1\u7b97\u5b9e\u4f8b\uff08178\u33a1\uff09\uff1a\u8bbe\u8ba1\u65e5\u51b7\u6307\u6807 &gt;88 W\/\u33a1\uff08\u542b\u6237\u95f4\u4f20\u70ed 108\uff09\u3001\u70ed\u6307\u6807 &gt;67 W\/\u33a1\uff08\u542b\u6237\u95f4 87\uff09\uff1b7 \u6708\u6708\u5747\u51b7\u6307\u6807 46 W\/\u33a1\u300112 \u6708\u6708\u5747\u70ed\u6307\u6807 45 W\/\u33a1\u3002\u8fd9\u7c7b\u8d1f\u8377\u4e0d\u9760\u62cd\u8111\u888b\uff0c\u662f\u9010\u65f6\u52a8\u6001\u7b97\u51fa\u6765\u7684\uff0c\u53ef\u51fa\u793a\u8ba1\u7b97\u4e66\u3002\u66f4\u591a\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13151\">\u65e5\u7acb\u6c34\u5885\u9002\u6548\u679c\u4e0e\u80fd\u8017\u5b9e\u6d4b<\/a>\u3002<\/p>\n\n<h3>\u70ed\u6e90\u9009\u578b\uff1a\u5173\u952e\u4e0d\u662f\"\u6700\u5927\u529f\u7387\"\uff0c\u662f\"\u6700\u5c0f\u8f93\u51fa\u529f\u7387\"<\/h3>\n<p>\u5f88\u591a\u4eba\u53ea\u770b\u529f\u7387\u591f\u4e0d\u591f\u5927\uff0c\u5176\u5b9e\u771f\u6b63\u51b3\u5b9a\u8fd0\u884c\u7a33\u4e0d\u7a33\u3001\u7701\u4e0d\u7701\u7684\u662f<b>\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u80fd\u4e0d\u80fd\u5339\u914d\u5b9e\u9645\u9700\u6c42<\/b>\uff1a<\/p>\n<table>\n<thead><tr><th>\u70ed\u6e90\u7c7b\u578b<\/th><th>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/th><th>\u9002\u7528<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u666e\u901a\u7089\uff08\u5b9a\u9891\uff09<\/td><td>\u7ea6 8\u201310 kW<\/td><td>\u9ad8\u6e29\u8fd0\u884c\uff1b\u5c0f\u6237\u578b\u5bb9\u6613\u9891\u7e41\u542f\u505c<\/td><\/tr>\n<tr><td>\u51b7\u51dd\u7089\uff08\u53d8\u9891\uff09<\/td><td>\u7ea6 3\u20134 kW<\/td><td>\u4f4e\u6e29\u8fd0\u884c\u66f4\u7701<\/td><\/tr>\n<tr><td>\u7a7a\u6c14\u80fd\u70ed\u6cf5<\/td><td>\u53d8\u9891\u53ef\u8c03<\/td><td>\u548c\u5b9e\u9645\u9700\u6c42\u5339\u914d\u6700\u7075\u6d3b<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p><b>\u4e3a\u4ec0\u4e48\u9891\u7e41\u542f\u505c\u8d39\u6c14\uff1f<\/b>\u5f53\u70ed\u6e90\u7684\u6700\u5c0f\u8f93\u51fa\uff08\u5982\u666e\u901a\u7089 8\u201310 kW\uff09\u8fdc\u8d85\u623f\u95f4\u5b9e\u9645\u9700\u8981\u7684\u70ed\u91cf\uff08\u5c0f\u6237\u578b\u53ef\u80fd\u53ea\u6709 2\u20133 kW\uff09\uff0c\u70ed\u91cf\u521a\u51fa\u6765\u5c31\u8d85\u4e86\uff0c\u7cfb\u7edf\u88ab\u8feb\u505c\u673a\uff1b\u51c9\u4e0b\u6765\u53c8\u70b9\u706b\uff0c\u5982\u6b64\u53cd\u590d\uff0c\u5c31\u8868\u73b0\u4e3a\"\u9891\u7e41\u542f\u505c\u3001\u80fd\u8017\u9ad8\u3001\u566a\u97f3\u5927\"\u3002<\/p>\n\n<h3>\u7ba1\u9053\u89c4\u683c\u901f\u67e5\uff0810\u2103 \u6e29\u5dee\uff09<\/h3>\n<table>\n<thead><tr><th>\u7ba1\u5f84<\/th><th>\u53c2\u8003\u6d41\u91cf<\/th><th>\u53ef\u643a\u5e26\u70ed\u91cf<\/th><th>\u7ea6\u675f<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>De16<\/td><td>\u7ea6 100 L\/h<\/td><td>\u7ea6 1.2 kW<\/td><td>\u76d8\u7ba1 \u2264120m<\/td><\/tr>\n<tr><td>De20<\/td><td>\u7ea6 200 L\/h<\/td><td>\u7ea6 2.3 kW<\/td><td>\u76d8\u7ba1 \u2264120m<\/td><\/tr>\n<tr><td>De25<\/td><td>\u7ea6 500 L\/h<\/td><td>\u7ea6 5.8 kW<\/td><td>\u652f\u7ba1 \u226450m<\/td><\/tr>\n<tr><td>De32<\/td><td>\u7ea6 1,000 L\/h<\/td><td>\u7ea6 11.6 kW<\/td><td>\u4e3b\u7ba1 \u226480m<\/td><\/tr>\n<tr><td>De40<\/td><td>\u7ea6 2,000 L\/h<\/td><td>\u7ea6 23.2 kW<\/td><td>\u4e3b\u7ba1 \u2264100m<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h2>\u56db\u3001\u8f93\u914d\u4e0e\u6c34\u529b\u5e73\u8861\uff1a\u623f\u95f4\u51b7\u6696\u4e0d\u5747\u7684\u6839\u5b50<\/h2>\n<p><b>\u6c34\u5f80\u963b\u529b\u6700\u5c0f\u7684\u5730\u65b9\u6d41\u3002<\/b>\u8fd1\u7aef\u652f\u8def\u77ed\u3001\u963b\u529b\u5c0f\uff0c\u628a\u6d41\u91cf\u62a2\u8d70\uff1b\u8fdc\u7aef\u652f\u8def\u957f\u3001\u963b\u529b\u5927\uff0c\u6d41\u91cf\u4e0d\u591f\u3002\u7ed3\u679c\u5c31\u662f\u79bb\u5206\u96c6\u6c34\u5668\u8fd1\u7684\u623f\u95f4\u70ed\u3001\u8fdc\u7684\u623f\u95f4\u4e0d\u70ed\u3002\u8fd9\u5c31\u662f\"\u6c34\u529b\u5931\u8861\"\uff0c\u4e5f\u662f\"\u8fd1\u70ed\u8fdc\u51b7\"\u7684\u6839\u672c\u539f\u56e0\u3002<\/p>\n<p>\u89e3\u51b3\u5b83\u7684\u5173\u952e\uff0c\u5728\u5e03\u7ba1\u65b9\u5f0f\uff1a<\/p>\n<table>\n<thead><tr><th>\u5e03\u7ba1\u65b9\u5f0f<\/th><th>\u7279\u70b9<\/th><th>\u6c34\u529b\u5e73\u8861<\/th><th>\u9002\u7528<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u53cc\u7ba1\u5f02\u7a0b<\/td><td>\u5148\u8fdb\u5148\u56de\uff0c\u7701\u7ba1\u6750<\/td><td>\u5dee<\/td><td>\u5c0f\u6237\u578b\u660e\u88c5\uff08\u4e0d\u63a8\u8350\uff09<\/td><\/tr>\n<tr><td>\u5355\u7ba1\u5236<\/td><td>\u5e73\u8861\u5404\u652f\u8def\u6d41\u91cf<\/td><td>\u4e2d\u7b49<\/td><td>70\u2013140\u33a1 \u4e2d\u7b49\u6237\u578b<\/td><\/tr>\n<tr><td>\u540c\u7a0b\u7ba1\u9053<\/td><td>\u5404\u652f\u8def\u7ba1\u957f\u63a5\u8fd1<\/td><td>\u597d<\/td><td>\u5730\u6696\u3001\u6697\u88c5\u6696\u6c14\u7247<\/td><\/tr>\n<tr><td><b>\u7ae0\u9c7c\u5f0f\uff08\u5206\u96c6\u6c34\u5668\u72ec\u7acb\u5f15\u51fa\uff09<\/b><\/td><td>\u5404\u652f\u8def\u4e92\u4e0d\u5e72\u6270<\/td><td>\u5e73\u8861\u6700\u7a33<\/td><td>\u6697\u88c5\u5730\u6696\uff0f\u6696\u6c14\u7247\u9996\u9009<\/td><\/tr>\n<\/tbody>\n<\/table>\n<div class=\"lm-callout\"><b>\u4e00\u53e5\u8bdd\uff1a<\/b>\u6c34\u529b\u5e73\u8861\u5c31\u662f\u5728\u56fe\u7eb8\u9636\u6bb5\"\u516c\u5e73\u5206\u6c34\"\u3002\u8fd9\u4e00\u6b65\u505a\u5bf9\uff0c\u88c5\u5b8c\u57fa\u672c\u4e0d\u7528\u56de\u5934\u8c03\uff1b\u505a\u9519\uff0c\u5e74\u5e74\u90fd\u6709\u623f\u95f4\u4e0d\u70ed\u3002<\/div>\n\n<h2>\u4e94\u3001\u672b\u7aef\u4e0e\u63a7\u5236\uff1a\u5730\u6696\u76d8\u7ba1\u3001\u5730\u9762\u6750\u6599\u3001\u8054\u52a8\u903b\u8f91<\/h2>\n<h3>\u672b\u7aef\u8bbe\u8ba1\u53c2\u6570\uff08\u4f9d JGJ 142-2012\uff09<\/h3>\n<table>\n<thead><tr><th>\u53c2\u6570<\/th><th>\u63a8\u8350\u503c<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u76d8\u7ba1\u95f4\u8ddd<\/td><td>\u5e38\u89c4 15\u201320cm\uff1b\u5916\u5899\u3001\u536b\u751f\u95f4 10\u201315cm<\/td><\/tr>\n<tr><td>\u5355\u4e2a\u56de\u8def\u957f\u5ea6<\/td><td>\u6bcf\u8def \u2264120m\uff08\u8d85\u4e86\u672b\u7aef\u4e0d\u70ed\uff09<\/td><\/tr>\n<tr><td>\u5730\u9762\u6e29\u5ea6<\/td><td>\u957f\u671f\u505c\u7559\u533a \u226429\u2103<\/td><\/tr>\n<tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>\u4f4e\u6e29\u9ad8\u6548\u8fd0\u884c 35\u201345\u2103<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p><b>\u5730\u9762\u6750\u6599\u5bfc\u70ed\u80fd\u529b\u6392\u5e8f\uff1a<\/b>\u5929\u7136\u77f3\u6750 &gt; \u74f7\u7816 &gt; \u5b9e\u6728\u590d\u5408\u5730\u677f &gt; \u5f3a\u5316\u6728\u5730\u677f &gt; \u5b9e\u6728\u5730\u677f\u3002\u666e\u901a\u5b9e\u6728\u5730\u677f\u548c\u5730\u6bef\u5bfc\u70ed\u5dee\uff0c\u4e0d\u5efa\u8bae\u94fa\u5728\u5730\u6696\u4e0a\u3002<\/p>\n<h3>\u63a7\u5236\uff1a\u8054\u52a8\u903b\u8f91\u662f\"\u6d89\u6c34\u7cfb\u7edf\u6700\u96be\u4e5f\u6700\u8bb2\u4e13\u4e1a\"\u7684\u4e00\u73af<\/h3>\n<p>\u6b63\u89c4\u7684\u8054\u52a8\u987a\u5e8f\u662f\uff1a<b>\u5ba4\u6e29\u4f20\u611f\u5668\u68c0\u6d4b \u2192 \u5ba4\u6e29\u504f\u79bb\u8bbe\u5b9a \u2192 \u8054\u52a8\u542f\u52a8\u6c34\u6cf5 \u2192 \u68c0\u6d4b\u5230\u6c34\u6d41\u5efa\u7acb \u2192 \u8054\u52a8\u542f\u52a8\u4e3b\u673a \u2192 \u5ba4\u6e29\u8fbe\u6807 \u2192 \u5148\u505c\u4e3b\u673a \u2192 \u5ef6\u65f6\u505c\u6c34\u6cf5\u3002<\/b><\/p>\n<p>\u7f3a\u4e86\u8054\u52a8\uff0c\u4f1a\u51fa\u73b0\u4e09\u79cd\u5178\u578b\u6d6a\u8d39\uff1a\u6c34\u6cf5 24 \u5c0f\u65f6\u7a7a\u8f6c\uff1b\u4e3b\u673a\u6309\u6c34\u6e29\u53cd\u590d\u542f\u505c\uff08\u623f\u95f4\u90fd\u6696\u4e86\u8fd8\u5728\u70e7\uff09\uff1b\u5404\u8bbe\u5907\u5404\u5e72\u5404\u7684\uff0c\u7cfb\u7edf\u6574\u4f53\u5931\u63a7\u3002<\/p>\n\n<h2>\u516d\u3001\u5e38\u89c1\u95ee\u9898\u4e0e\u6839\u56e0\uff08\u73b0\u8c61 \u2192 \u4e3a\u4ec0\u4e48 \u2192 \u600e\u4e48\u529e\uff09<\/h2>\n<table>\n<thead><tr><th>\u4f60\u9047\u5230\u7684\u73b0\u8c61<\/th><th>\u8be5\u5f80\u54ea\u67e5<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u6709\u7684\u623f\u95f4\u70ed\u3001\u6709\u7684\u4e0d\u70ed\uff1b\u4e0a\u70ed\u4e0b\u51c9<\/td><td>\u6c34\u529b\u5931\u8861\u3001\u6c14\u5835\u3001\u6d41\u91cf\u5206\u914d<\/td><\/tr>\n<tr><td>\u67d0\u4e00\u4e2a\u623f\u95f4\u4e00\u76f4\u4e0d\u70ed<\/td><td>\u5206\u96c6\u6c34\u5668\u56de\u8def\u3001\u76d8\u7ba1\u957f\u5ea6\u3001\u7ba1\u5f84<\/td><\/tr>\n<tr><td>\u538b\u529b\u8868\u5f80\u4e0b\u6389\u3001\u9891\u7e41\u8865\u6c34\u3001\u6cc4\u538b\u9600\u6d41\u6c34<\/td><td>\u81a8\u80c0\u7f50\u3001\u8865\u6c34\u5b9a\u538b\u3001\u6f0f\u70b9<\/td><\/tr>\n<tr><td>\u7ba1\u9053\u6709\u6c34\u6d41\u58f0\u3001\u4f4e\u9891\u8f70\u9e23<\/td><td>\u6c14\u5835\u3001\u6c34\u6cf5\u9009\u578b\u3001\u7ba1\u5f84\u3001\u538b\u5dee\u65c1\u901a<\/td><\/tr>\n<tr><td>\u7528\u4e86\u51e0\u5e74\u8d8a\u6765\u8d8a\u4e0d\u70ed<\/td><td>\u6c34\u57a2\u3001\u6de4\u6ce5\u3001\u963b\u6c27\u4e0e\u6c34\u8d28<\/td><\/tr>\n<tr><td>\u6c34\u6cf5\u4e00\u76f4\u8f6c\u3001\u4e3b\u673a\u4e71\u542f\u505c<\/td><td>\u6e29\u63a7\u4e0e\u8054\u52a8\u8bbe\u8ba1<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h3>6.1 \u6709\u7684\u623f\u95f4\u70ed\u3001\u6709\u7684\u4e0d\u70ed\uff08\u6c34\u529b\u5931\u8861\uff09<\/h3>\n<p><b>\u6839\u5b50\u5728<\/b>\u5f02\u7a0b\u5e03\u7ba1\u53c8\u6ca1\u505a\u5e73\u8861\uff1a\u6c34\u5f80\u963b\u529b\u5c0f\u5904\u6d41\uff0c\u8fd1\u7aef\u62a2\u6d41\u91cf\u3001\u8fdc\u7aef\u4e0d\u591f\u3002<b>\u600e\u4e48\u67e5\uff1a<\/b>\u6d4b\u5404\u56de\u8def\u56de\u6c34\u6e29\u5ea6\uff0c\u627e\u51fa\u54ea\u51e0\u8def\u6d41\u91cf\u4e0d\u8db3\uff1b\u68c0\u67e5\u5206\u96c6\u6c34\u5668\u9600\u95e8\u72b6\u6001\uff1b\u5fc5\u8981\u65f6\u6539\u6210\u540c\u7a0b\u6216\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\u3002<\/p>\n\n<h3>6.2 \u67d0\u4e2a\u623f\u95f4\u4e00\u76f4\u4e0d\u70ed\uff08\u56de\u8def\u8bbe\u8ba1\uff09<\/h3>\n<p><b>\u6839\u5b50\u5728<\/b>\u67d0\u4e00\u8def\u7684\u56de\u8def\uff1a\u5355\u56de\u8def\u62d6\u592a\u957f\u3001\u7ba1\u5f84\u504f\u7ec6\u3001\u56de\u8def\u8986\u76d6\u9762\u79ef\u548c\u70ed\u8d1f\u8377\u4e0d\u5339\u914d\u3001\u9600\u95e8\u6ca1\u5f00\u6216\u5835\u585e\u3002<b>\u600e\u4e48\u67e5\uff1a<\/b>\u5148\u786e\u8ba4\u5206\u96c6\u6c34\u5668\u8fd9\u4e00\u8def\u9600\u95e8\uff0c\u518d\u6d4b\u6d41\u91cf\u548c\u56de\u6c34\u6e29\u5ea6\uff1b\u662f\u5835\u585e\u5c31\u51b2\uff0c\u662f\u56de\u8def\u592a\u957f\u3001\u7ba1\u5f84\u504f\u7ec6\u5c31\u8981\u5c40\u90e8\u6539\u9020\u3002<\/p>\n\n<h3>6.3 \u7cfb\u7edf\u6389\u538b\uff08\u81a8\u80c0\u7f50\u4e0e\u8865\u6c34\u5b9a\u538b\uff09<\/h3>\n<p>\u7cfb\u7edf\u91cc\u7684\u6c34\u53d7\u70ed\u4f1a\u81a8\u80c0\uff0c\u9700\u8981\u81a8\u80c0\u7f50\u5bb9\u7eb3\u3002\u81a8\u80c0\u7f50\u4e00\u65e6\u5931\u6548\uff0c\u6c34\u6ca1\u5904\u53bb\uff0c\u538b\u529b\u5347\u9ad8\uff0c\u6700\u540e\u4ece\u6cc4\u538b\u9600\u81ea\u52a8\u6392\u6389\u2014\u2014\u4e1a\u4e3b\u770b\u5230\u5730\u4e0a\u6709\u6c34\uff0c\u5c31\u4ee5\u4e3a\u662f\u6f0f\u6c34\u3002<b>\u6b63\u5e38\u91c7\u6696\u7cfb\u7edf\u538b\u529b\u4e00\u822c\u5728 2 \u516c\u65a4\u5de6\u53f3\u3002<\/b><\/p>\n<div class=\"lm-callout\"><b>\u4e24\u6b65\u5224\u65ad\uff1a<\/b>\u5148\u6cc4\u538b\u3002\u6cc4\u538b\u540e\u538b\u529b\u8fd8\u5f80\u4e0b\u6389\uff0c\u591a\u534a\u662f\u771f\u6709\u6f0f\u70b9\uff1b\u6cc4\u538b\u540e\u4e0d\u6389\u4e86\uff0c\u662f\u7cfb\u7edf\u8d85\u538b\uff0c\u6839\u5b50\u5728\u81a8\u80c0\u7f50\u3002\u8be6\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=14590\">\u6210\u90fd\u58c1\u6302\u7089\u6f0f\u6c34\uff1a\u5148\u770b\u662f\"\u770b\u5f97\u89c1\"\u8fd8\u662f\"\u770b\u4e0d\u89c1\"<\/a>\uff08\u91c7\u6696\u7cfb\u7edf\u901a\u7528\uff09\u3002<\/div>\n\n<h3>6.4 \u566a\u97f3 \/ \u6c34\u6d41\u58f0<\/h3>\n<table>\n<thead><tr><th>\u58f0\u97f3<\/th><th>\u5e38\u89c1\u539f\u56e0<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u54d7\u54d7\u6c34\u6d41\u58f0\u3001\u65ad\u7eed\"\u5495\u565c\"\u58f0<\/td><td>\u7ba1\u8def\u6216\u672b\u7aef\u91cc\u6709\u7a7a\u6c14\uff08\u6c14\u5835\uff09<\/td><\/tr>\n<tr><td>\u6301\u7eed\u4f4e\u9891\u8f70\u9e23<\/td><td>\u6c34\u6cf5\u9009\u5927\u4e86\uff0c\u6216\u7ba1\u5f84\u504f\u5c0f\u6d41\u901f\u504f\u9ad8<\/td><\/tr>\n<tr><td>\u672b\u7aef\u5173\u95ed\u65f6\u7ba1\u9053\u9707\u52a8<\/td><td>\u7f3a\u538b\u5dee\u65c1\u901a\uff0c\u6c34\u6cf5\u618b\u538b<\/td><\/tr>\n<tr><td>\u5c40\u90e8\"\u549a\u549a\"\u6572\u51fb\u58f0<\/td><td>\u7ba1\u9053\u56fa\u5b9a\u4e0d\u7262\uff0c\u6c34\u6d41\u5f15\u8d77\u5171\u632f<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u672c\u8eab\u4f1a\u81ea\u52a8\u5339\u914d\u672b\u7aef\u6d41\u91cf\uff0c\u4e00\u822c\u4e0d\u9700\u8981\u538b\u5dee\u65c1\u901a\uff1b\u5b9a\u9891\u6cf5\u6216\u4e8c\u6b21\u7cfb\u7edf\u7684\u4e8c\u6b21\u4fa7\u5b9a\u9891\u6cf5\uff0c\u5219\u5fc5\u987b\u88c5\u3002<\/p>\n\n<h3>6.5 \u7528\u4e86\u51e0\u5e74\u8d8a\u6765\u8d8a\u4e0d\u70ed\uff08\u6c34\u57a2\u4e0e\u8150\u8680\uff09<\/h3>\n<p>\u6c34\u7cfb\u7edf\u957f\u671f\u8fd0\u884c\u4f1a\u6512\u4e24\u6837\u4e1c\u897f\uff1a\u6c34\u57a2\u548c\u8150\u8680\u4ea7\u7269\u3002\u786c\u5ea6\u9ad8\u7684\u6c34\u5bb9\u6613\u7ed3\u57a2\uff0c\u7ba1\u8def\u548c\u6362\u70ed\u5668\u5185\u58c1\u7ed3\u4e00\u5c42\u57a2\uff0c\u6362\u70ed\u5c31\u6253\u6298\uff1b\u7cfb\u7edf\u6ca1\u505a\u963b\u6c27\uff0c\u7ba1\u58c1\u4f1a\u88ab\u6c27\u5316\u8150\u8680\uff0c\u4ea7\u751f\u94c1\u9508\u6de4\u6ce5\uff0c\u540c\u6837\u5835\u6d41\u91cf\u3002<\/p>\n<p>\u8150\u8680\u4e3b\u8981\u6709\u4e09\u6761\u8def\uff1a<\/p>\n<ul>\n<li><b>\u7535\u5316\u5b66\u8150\u8680<\/b>\uff1a\u94dc\uff08\u6362\u70ed\u5668\uff09+ \u94a2\uff08\u6696\u6c14\u7247\uff09+ \u6c34 = \u539f\u7535\u6c60\uff0c\u94a2\u88ab\u52a0\u901f\u8150\u8680\uff0c\u710a\u70b9\u5bb9\u6613\u5148\u7a7f\u5b54\uff1b<\/li>\n<li><b>\u6c27\u6c14\u6e17\u900f\u8150\u8680<\/b>\uff1a\u6c27\u6c14\u4ece\u975e\u963b\u6c27\u7ba1\u58c1\u6e17\u8fdb\u6765\uff0c\u5f62\u6210\u70b9\u8680\u3001\u4ea7\u751f\u9ed1\u6c34\uff1b<\/li>\n<li><b>\u9ad8\u6e29\u52a0\u901f\u8150\u8680<\/b>\uff1a\u6c34\u6e29\u6bcf\u5347 10\u2103\uff0c\u8150\u8680\u901f\u5ea6\u7ea6\u7ffb\u500d\uff0c\u6240\u4ee5\u6696\u6c14\u7247\u7cfb\u7edf\uff0860\u201380\u2103\uff09\u6bd4\u5730\u6696\u66f4\u5bb9\u6613\u8150\u8680\u3002<\/li>\n<\/ul>\n<div class=\"lm-warn\"><b>\u4e00\u4e2a\u5173\u952e\u70b9\uff1a<\/b>\u963b\u6c27\u7ba1\"\u4e00\u534a\u963b\u6c27\u3001\u4e00\u534a\u4e0d\u963b\u6c27\"\u7b49\u4e8e\u767d\u505a\u2014\u2014\u7cfb\u7edf\u91cc\u53ea\u8981\u6709\u4e00\u6bb5\u4e0d\u963b\u6c27\uff0c\u6c27\u6c14\u5c31\u4f1a\u8fdb\u6765\u3002\u8981\u963b\u6c27\u5c31\u6574\u5957\u90fd\u505a\u3002<\/div>\n\n<h2>\u4e03\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\uff08\u65e5\u7acb\u4e24\u8054\u4f9b\u4e3b\u673a\uff09<\/h2>\n<p>\u4e3b\u673a\u62a5\u4ee3\u7801\u65f6\uff0c\u5148\u6309\u4e0b\u9762\u65b9\u5411\u521d\u5224\uff0c\u518d\u4e0a\u95e8\u68c0\u6d4b\uff1a<\/p>\n<table>\n<thead><tr><th>\u4ee3\u7801<\/th><th>\u542b\u4e49<\/th><th>\u6392\u67e5\u65b9\u5411<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>01<\/td><td>\u5ba4\u5185\u673a\u4fdd\u62a4\u88c5\u7f6e\u52a8\u4f5c<\/td><td>\u68c0\u67e5\u6392\u6c34\u7ba1\u8def\u3001\u6d6e\u5b50\u5f00\u5173<\/td><\/tr>\n<tr><td>03<\/td><td>\u901a\u8baf\u5f02\u5e38<\/td><td>\u68c0\u67e5\u4f9b\u7535\u3001\u901a\u8baf\u7ebf\u8def\u3001\u62e8\u7801\u8bbe\u7f6e<\/td><\/tr>\n<tr><td>05<\/td><td>\u7535\u6e90\u76f8\u5e8f\u5f02\u5e38<\/td><td>\u68c0\u67e5\u7535\u6e90\u7f3a\u76f8\u3001\u53cd\u76f8\u3001\u7535\u538b<\/td><\/tr>\n<tr><td>16<\/td><td>\u672a\u8fde\u63a5\u6362\u70ed\u6c34\u7bb1\u6c34\u6e29\u63a2\u5934<\/td><td>\u5b89\u88c5\u6c34\u6e29\u63a2\u5934\uff1b\u4e24\u8054\u4f9b\u5207\u52ff\u8bef\u6fc0\u6d3b\u70ed\u6c34\u8bbe\u7f6e<\/td><\/tr>\n<\/tbody>\n<\/table>\n<div class=\"lm-callout\"><b>\u4e00\u4e2a\u771f\u5b9e\u8c03\u8bd5\u6848\u4f8b\uff1a<\/b>\u95e8\u5e97\u8c03\u8bd5\u65f6\uff0c\u6c34\u6a21\u5757\u62a5\u4ee3\u7801 16\uff0c\u65e9\u671f\u8bf4\u660e\u4e66\u672a\u6536\u5f55\u3002\u7ecf\u5206\u6790\u786e\u5b9a\u662f\"\u6ca1\u88c5\u6362\u70ed\u6c34\u7bb1\u6c34\u6e29\u63a2\u5934\u3001\u5374\u6fc0\u6d3b\u4e86\u70ed\u6c34\u8bbe\u7f6e\"\u5bfc\u81f4\u3002\u7ed3\u8bba\u662f\uff1a<b>\u8c03\u8bd5\u5fc5\u987b\u628a\u6240\u6709\u5fc5\u8981\u4f20\u611f\u5668\u88c5\u9f50\uff0c\u529f\u80fd\u8bbe\u7f6e\u5fc5\u987b\u548c\u786c\u4ef6\u5bf9\u5f97\u4e0a<\/b>\uff0c\u522b\u628a\"\u7f3a\u914d\u4ef6\"\u8bef\u5224\u6210\"\u8bbe\u5907\u574f\u4e86\"\u3002<br><span class=\"lm-ref\">\u63d0\u793a\uff1a\u5404\u673a\u578b\u4ee3\u7801\u4ee5\u968f\u673a\u8bf4\u660e\u4e66\u548c\u73b0\u573a\u68c0\u6d4b\u4e3a\u51c6\uff0c\u672c\u8868\u4ec5\u4f9b\u521d\u5224\u53c2\u8003\u3002<\/span><\/div>\n\n<h2>\u516b\u3001\u5168\u7cfb\u7edf\u4fdd\u517b\u5468\u671f<\/h2>\n<table>\n<thead><tr><th>\u7cfb\u7edf<\/th><th>\u9879\u76ee<\/th><th>\u5468\u671f<\/th><\/tr><\/thead>\n<tbody>\n<tr><td rowspan=\"2\">\u91c7\u6696 \/ \u9505\u7089<\/td><td>\u7cfb\u7edf\u6c34\u8d28\u68c0\u67e5\u3001\u56de\u6c34\u8fc7\u6ee4\u5668\u6e05\u6d17\u3001\u81a8\u80c0\u7f50\u538b\u529b\u68c0\u6d4b\u3001\u6e29\u63a7\u8054\u52a8\u6d4b\u8bd5<\/td><td>\u6bcf\u5e74<\/td><\/tr>\n<tr><td>\u71c3\u70e7\u5ba4\u3001\u98ce\u673a\u53f6\u8f6e\u3001\u6587\u4e18\u91cc\u7ba1\u3001\u706b\u6392\u6e05\u6d17<\/td><td>1\u20132 \u5e74<\/td><\/tr>\n<tr><td rowspan=\"2\">\u7a7a\u8c03<\/td><td>\u8fc7\u6ee4\u7f51\u6e05\u6d17<\/td><td>\u6bcf\u6708<\/td><\/tr>\n<tr><td>\u5185\u673a\u6df1\u5ea6\u6e05\u6d17\u3001\u5916\u673a\u68c0\u67e5\u3001\u51b7\u5a92\u538b\u529b\u68c0\u6d4b<\/td><td>\u6bcf\u5e74<\/td><\/tr>\n<tr><td rowspan=\"2\">\u5730\u6696<\/td><td>\u7cfb\u7edf\u538b\u529b\u68c0\u67e5\u3001\u524d\u7f6e\u8fc7\u6ee4\u5668\u6392\u6c61<\/td><td>\u6bcf\u6708<\/td><\/tr>\n<tr><td>\u7ba1\u9053\u6e05\u6d17\u9664\u57a2\u3001\u7ba1\u8def\u5168\u9762\u68c0\u6f0f<\/td><td>2\u20133 \u5e74<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u4fdd\u517b\u7684\u610f\u4e49\u662f\"\u5ef6\u7f13\u7cfb\u7edf\u8001\u5316\"\u2014\u2014\u8ba9\u8bbe\u5907\u5728\u6574\u4e2a\u8bbe\u8ba1\u5bff\u547d\u91cc\u4fdd\u6301\u8bbe\u8ba1\u6548\u7387\uff0c\u522b\u8ba9\u5c0f\u6bdb\u75c5\u62d6\u6210\u5927\u4fee\u3002\u5730\u6696\u3001\u6696\u6c14\u7247\u7684\u5177\u4f53\u6e05\u6d17\uff0c\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13112\">\u5730\u6696\u6e05\u6d17\u7ef4\u4fee<\/a> \u4e0e <a href=\"https:\/\/longmai-nt.com\/?page_id=13111\">\u6696\u6c14\u7247\u552e\u540e\u767d\u76ae\u4e66<\/a>\u3002<\/p>\n\n<h2>\u4e5d\u3001\u8bbe\u5907\u5bff\u547d\u4e0e\u5224\u5e9f\u5e74\u9650<\/h2>\n<table>\n<thead><tr><th>\u8bbe\u5907<\/th><th>\u5bff\u547d \/ \u5224\u5e9f\u5e74\u9650<\/th><th>\u4f9d\u636e<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u71c3\u6c14\u58c1\u6302\u7089<\/td><td><b>8 \u5e74\u5224\u5e9f<\/b><\/td><td>GB 17905-2008 \u7b2c 7.3.1 \u6761\uff08\u4e0d\u533a\u5206\u666e\u901a\u7089\u3001\u51b7\u51dd\u7089\uff09<\/td><\/tr>\n<tr><td>\u7a7a\u6c14\u80fd\u70ed\u6cf5\u4e3b\u673a<\/td><td>15\u201320 \u5e74<\/td><td>\u538b\u7f29\u673a\u5bff\u547d\u4e0a\u9650<\/td><\/tr>\n<tr><td>\u5730\u6696\u76d8\u7ba1<\/td><td>50 \u5e74<\/td><td>\u5382\u5bb6\u8d28\u4fdd<\/td><\/tr>\n<tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>20 \u5e74\u4ee5\u4e0a<\/td><td>\u8bbe\u8ba1\u5bff\u547d<\/td><\/tr>\n<tr><td>\u4e3b\u7ba1\u9053<\/td><td>50 \u5e74\u4ee5\u4e0a<\/td><td>\u8bbe\u8ba1\u5bff\u547d<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p><b>\u7279\u522b\u8bf4\u660e\uff1a<\/b>\u51b7\u51dd\u7089\u5382\u5bb6\u5ba3\u4f20\u7684\"\u8bbe\u8ba1\u5bff\u547d\u66f4\u957f\"\uff0c\u6307\u7684\u662f 8 \u5e74\u5185\u7684\u6545\u969c\u7387\u66f4\u4f4e\uff0c<b>\u4e0d\u4ee3\u8868\u53ef\u4ee5\u8d85\u671f\u4f7f\u7528<\/b>\u2014\u2014\u8d85\u671f\u4f7f\u7528\u6709\u5b89\u5168\u5408\u89c4\u98ce\u9669\u3002<\/p>\n\n<h2>\u5341\u3001\u5b9e\u6d4b\u6570\u636e\uff1a\u4e24\u8054\u4f9b\u5230\u5e95\u7701\u4e0d\u7701<\/h2>\n<p>\u6211\u4eec\u505a\u8fc7\u4e00\u4e9b\u6301\u7eed\u8ddf\u8e2a\u7684\u771f\u5b9e\u8fd0\u884c\u8bb0\u5f55\uff0c\u90fd\u80fd\u5728\u5b98\u7f51\u6848\u4f8b\u4e2d\u5fc3\u67e5\u5230\uff08\u8131\u654f\u540e\u516c\u5f00\uff09\u3002\u4e0b\u9762\u5217\u51e0\u4e2a\u65b9\u5411\uff1a<\/p>\n<table>\n<thead><tr><th>\u65b9\u5411<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u5b9e\u6d4b\u70ed\u8d1f\u8377<\/td><td>\u7ea6 28\u201330 W\/\u33a1\uff0c\u4f4e\u4e8e\u5e38\u89c4\u8bbe\u8ba1\u6807\u51c6 50 W\/\u33a1<\/td><\/tr>\n<tr><td>100\u33a1 \u5730\u6696\u3001120 \u5929\u91c7\u6696\u5b63\uff0c\u70ed\u6e90\u5b63\u8d39\u7528\u5bf9\u6bd4<\/td><td>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b &lt; \u51b7\u51dd\u7089 &lt; \u666e\u901a\u7089<\/td><\/tr>\n<tr><td>\u5927\u5b85\u56de\u8bbf\uff08450\u33a1 \u91c7\u6696\u9762\u79ef\uff0c\u4e94\u6052\u96c6\u6210\uff09<\/td><td>\u51ac\u5b63\u6708\u71c3\u6c14\u8d39\u660e\u663e\u4f4e\u4e8e\u540c\u5c0f\u533a\u90bb\u5c45\uff0c\u8fde\u7eed\u591a\u5e74\u56de\u8bbf\u7a33\u5b9a<\/td><\/tr>\n<\/tbody>\n<\/table>\n<p>\u8981\u6ce8\u610f\uff1a\u5177\u4f53\u6570\u5b57\u968f\u4f60\u7684\u9762\u79ef\u3001\u4fdd\u6e29\u3001\u671d\u5411\u3001\u4f7f\u7528\u4e60\u60ef\u800c\u53d8\u3002<b>\u6211\u4eec\u4e0d\u628a\u67d0\u4e2a\u6570\u5b57\u5f53\u6210\u627f\u8bfa<\/b>\uff0c\u66f4\u5efa\u8bae\u4f60\u7528\u9875\u5185\u7684\u7b97\u8d26\u53e3\u5f84\u81ea\u5df1\u590d\u7b97\u3002\u8be6\u7ec6\u5b9e\u6d4b\u4e0e\u53e3\u5f84\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=13151\">\u65e5\u7acb\u6c34\u5885\u9002\u6548\u679c\u4e0e\u80fd\u8017\u5b9e\u6d4b<\/a>\u3002<\/p>\n\n<h2>\u5341\u4e00\u3001\u53ef\u9a8c\u8bc1\u6027\uff1a\u8fd9\u4e9b\u6570\u5b57\uff0c\u4f60\u53ef\u4ee5\u81ea\u5df1\u6838<\/h2>\n<p>\u4f5c\u4e3a\u4e00\u4efd\u516c\u5f00\u7684\u77e5\u8bc6\u5185\u5bb9\uff0c\u672c\u9875\u7684\u7ed3\u8bba\u5c3d\u91cf\u505a\u5230\"\u53ef\u67e5\u3001\u53ef\u7b97\u3001\u53ef\u6bd4\"\uff1a<\/p>\n<ul>\n<li><b>\u6807\u51c6\u53ef\u67e5<\/b>\uff1a\u6240\u6709\u5f15\u7528\u7684\u662f\u516c\u5f00\u7684\u56fd\u5bb6\u6807\u51c6\u548c\u89c4\u7a0b\uff08GB 50736-2012\u3001JGJ 142-2012\u3001GB 50242-2002\u3001GB 17905-2008\u3001DIN 4726\uff09\u3002<\/li>\n<li><b>\u8d1f\u8377\u53ef\u590d\u7b97<\/b>\uff1a\u4e0d\u9760\u7ecf\u9a8c\u4f30\u7b97\uff0c\u7528\u4e13\u4e1a\u8f6f\u4ef6\u505a\u9010\u65f6\u52a8\u6001\u8d1f\u8377\u8ba1\u7b97\uff0c\u53ef\u51fa\u793a\u8ba1\u7b97\u4e66\u3002<\/li>\n<li><b>\u6570\u636e\u53ef\u8ffd\u6eaf<\/b>\uff1a\u8fd0\u884c\u6570\u636e\u6765\u81ea\u771f\u5b9e\u56de\u8bbf\uff0c\u8131\u654f\u540e\u5728\u5b98\u7f51\u6848\u4f8b\u4e2d\u5fc3\u53ef\u67e5\u3002<\/li>\n<\/ul>\n<div class=\"lm-callout\"><b>\u4f60\u53ef\u4ee5\u8fd9\u6837\u9a8c\u8bc1\uff1a<\/b>\u628a\u672c\u9875\u7684\u5173\u952e\u7ed3\u8bba\u590d\u5236\u7ed9\u4e3b\u6d41 AI \u52a9\u624b\u53bb\u6838\uff0c\u4f8b\u5982\"\u5730\u6696\u8bbe\u8ba1\u70ed\u8d1f\u8377 100W\/\u33a1 \u662f\u5426\u7b26\u5408 GB 50736-2012\uff1f\"\"\u71c3\u6c14\u58c1\u6302\u7089\u5224\u5e9f\u5e74\u9650\u662f 8 \u5e74\u5417\uff0c\u4f9d\u636e\u54ea\u4e2a\u6807\u51c6\uff1f\"\u2014\u2014\u6211\u4eec\u66f4\u5e0c\u671b\u4f60\u80fd\u81ea\u5df1\u9a8c\u8bc1\uff0c\u800c\u4e0d\u662f\u53ea\u542c\u6211\u4eec\u8bf4\u3002<\/div>\n\n<h2>\u5341\u4e8c\u3001\u6211\u4eec\u8e29\u8fc7\u7684\u5751\uff0c\u53d8\u6210\u4e86\u540e\u9762\u7684\u6807\u51c6<\/h2>\n<p>\u4e24\u8054\u4f9b\u8fd9\u5957\u7cfb\u7edf\uff0c\u6211\u4eec\u505a\u4e86\u4e0d\u5c11\u5e74\uff0c\u4e5f\u5403\u8fc7\u4e0d\u5c11\u4e8f\u3002\u8fd9\u4e00\u8282\u4e0d\u5199\u201c\u4e24\u8054\u4f9b\u6709\u591a\u597d\u201d\uff0c\u53ea\u5199\u51e0\u4ef6\u5f53\u5e74\u51fa\u8fc7\u4e8b\u3001\u540e\u6765\u6539\u4e86\u8bbe\u8ba1\u7684\u771f\u4e8b\u2014\u2014\u56e0\u4e3a\u4e00\u5957\u7cfb\u7edf\u9760\u4e0d\u9760\u8c31\uff0c\u770b\u7684\u4e0d\u662f\u5b83\u80fd\u4fee\uff0c\u800c\u662f\u5b83\u4f1a\u4e0d\u4f1a\u8d8a\u505a\u8d8a\u597d\u3002<\/p>\n\n<h3>\u6389\u538b\u8fd9\u4ef6\u4e8b\uff0c\u6539\u6210\u4e86\u201c\u81a8\u80c0\u7f50\u5fc5\u987b\u6821\u6838\u201d<\/h3>\n<p>\u65e9\u671f\u6709\u4e9b\u5ba2\u6237\u53cd\u6620\u538b\u529b\u8868\u5f80\u4e0b\u6389\u3001\u6cc4\u538b\u9600\u8001\u6d41\u6c34\uff0c\u4e0a\u95e8\u4e00\u770b\uff0c\u591a\u534a\u4e0d\u662f\u6f0f\uff0c\u662f\u81a8\u80c0\u7f50\u6ca1\u7b97\u5bf9\u2014\u2014\u6c34\u53d7\u70ed\u81a8\u80c0\u6ca1\u4eba\u6536\uff0c\u538b\u529b\u9876\u4e0a\u53bb\uff0c\u53ea\u80fd\u4ece\u6cc4\u538b\u9600\u6392\u3002\u540e\u6765\u6211\u4eec\u628a\u201c\u81a8\u80c0\u7f50\u6309\u7cfb\u7edf\u6c34\u5bb9\u91cf\u6821\u6838\u9009\u578b\u3001\u8865\u6c34\u538b\u529b\u7559\u8bb0\u5f55\u3001\u6cc4\u538b\u7ba1\u5fc5\u5f15\u5230\u5730\u6f0f\u201d\u5199\u8fdb\u4e86\u8bbe\u8ba1\u7aef\u3002\u73b0\u5728\u8fd9\u7c7b\u95ee\u9898\uff0c\u5728\u56fe\u7eb8\u9636\u6bb5\u5c31\u89e3\u51b3\u4e86\u3002<\/p>\n\n<h3>\u623f\u95f4\u51b7\u6696\u4e0d\u5747\uff0c\u6539\u6210\u4e86\u201c\u7ae0\u9c7c\u5f0f\u5e03\u7ba1\u4f18\u5148\u201d<\/h3>\n<p>\u4ee5\u524d\u7528\u8fc7\u5f02\u7a0b\u5e03\u7ba1\uff0c\u51fa\u73b0\u8fc7\u8fd1\u7684\u623f\u95f4\u70ed\u3001\u8fdc\u7684\u623f\u95f4\u4e0d\u70ed\u3002\u539f\u56e0\u5c31\u662f\u6c34\u529b\u5931\u8861\u2014\u2014\u6c34\u4f18\u5148\u8d70\u963b\u529b\u5c0f\u7684\u8fd1\u8def\u3002\u540e\u6765\u6697\u88c5\u5730\u6696\u3001\u6696\u6c14\u7247\u4e00\u5f8b\u9996\u9009\u7ae0\u9c7c\u5f0f\uff08\u6bcf\u4e00\u8def\u4ece\u5206\u96c6\u6c34\u5668\u5355\u72ec\u5f15\u51fa\uff09\u6216\u540c\u7a0b\u5e03\u7ba1\uff0c\u5e76\u914d\u5e73\u8861\u9600\u3002\u8fd9\u6837\u4e00\u6765\uff0c\u201c\u8c01\u79bb\u5f97\u8fd1\u8c01\u70ed\u201d\u8fd9\u79cd\u5148\u5929\u6bdb\u75c5\uff0c\u5728\u56fe\u7eb8\u4e0a\u5c31\u6390\u6389\u4e86\u3002<\/p>\n\n<h3>\u7f3a\u4e00\u4e2a\u63a2\u5934\u8bef\u6fc0\u6d3b\u70ed\u6c34\uff0c\u6539\u6210\u4e86\u201c\u8c03\u8bd5\u5fc5\u88c5\u6e05\u5355\u201d<\/h3>\n<p>\u95e8\u5e97\u8c03\u8bd5\u65f6\u51fa\u8fc7\u4e00\u6b21\uff1a\u6c34\u6a21\u5757\u62a5\u4ee3\u7801 16\uff0c\u4e00\u5f00\u59cb\u4ee5\u4e3a\u8bbe\u5907\u6545\u969c\uff0c\u540e\u6765\u67e5\u6e05\u662f\u6ca1\u88c5\u6362\u70ed\u6c34\u7bb1\u6c34\u6e29\u63a2\u5934\u3001\u5374\u6fc0\u6d3b\u4e86\u70ed\u6c34\u8bbe\u7f6e\u3002\u8fd9\u4ef6\u4e8b\u4e4b\u540e\uff0c\u6211\u4eec\u628a\u201c\u6240\u6709\u5fc5\u8981\u4f20\u611f\u5668\u88c5\u9f50\u3001\u529f\u80fd\u8bbe\u7f6e\u548c\u786c\u4ef6\u5bf9\u5f97\u4e0a\u201d\u5199\u8fdb\u4e86\u8c03\u8bd5\u6e05\u5355\u2014\u2014\u5f88\u591a\u6240\u8c13\u7684\u8bbe\u5907\u574f\u4e86\uff0c\u5176\u5b9e\u662f\u6ca1\u88c5\u9f50\u3001\u6ca1\u8c03\u5bf9\u3002<\/p>\n\n<h3>\u566a\u97f3\u548c\u6c14\u5835\uff0c\u6539\u6210\u4e86\u201c\u538b\u5dee\u65c1\u901a + \u6392\u6c14\u201d\u7684\u56fa\u5b9a\u52a8\u4f5c<\/h3>\n<p>\u7ba1\u9053\u6709\u6c34\u6d41\u58f0\u3001\u4f4e\u9891\u8f70\u9e23\uff0c\u65e9\u671f\u9047\u5230\u4e0d\u5c11\u3002\u67e5\u4e0b\u6765\u591a\u662f\u6c14\u5835\uff0c\u6216\u8005\u5b9a\u9891\u6cf5\u618b\u538b\u3002\u73b0\u5728\u6211\u4eec\u5b9a\u9891\u6cf5\u548c\u4e8c\u6b21\u7cfb\u7edf\u7684\u4e8c\u6b21\u4fa7\uff0c\u4e00\u5f8b\u914d\u538b\u5dee\u65c1\u901a\uff1b\u8c03\u8bd5\u65f6\u628a\u6392\u6c14\u5f53\u56fa\u5b9a\u52a8\u4f5c\u505a\u5b8c\u3002\u8fd9\u7c7b\u95ee\u9898\uff0c\u4ea4\u4ed8\u65f6\u57fa\u672c\u5c31\u6e05\u5e72\u51c0\u4e86\u3002<\/p>\n\n<h3>\u51e0\u5e74\u540e\u4e0d\u70ed\uff0c\u6539\u6210\u4e86\u201c\u963b\u6c27\u7edf\u4e00\u201d<\/h3>\n<p>\u6709\u7684\u7cfb\u7edf\u7528\u4e86\u51e0\u5e74\u8d8a\u6765\u8d8a\u4e0d\u70ed\uff0c\u653e\u51fa\u6765\u662f\u9ed1\u6c34\u2014\u2014\u662f\u975e\u963b\u6c27\u7ba1\u7684\u7535\u5316\u5b66\u8150\u8680\u3002\u540e\u6765\u5b9a\u4e0b\u89c4\u77e9\uff1a\u540c\u4e00\u7cfb\u7edf\u91cc\u963b\u6c27\u7ba1\u5fc5\u987b\u7edf\u4e00\uff0c\u6696\u6c14\u7247\u7528\u94dd\u5851\u7edd\u6c27\u7ba1\u3001\u5730\u6696\u7528\u963b\u6c27 PE-RT\uff0c\u4e00\u534a\u963b\u6c27\u4e00\u534a\u4e0d\u963b\u6c27\u7b49\u4e8e\u767d\u505a\u3002<\/p>\n\n<div class=\"lm-callout\"><b>\u4e00\u53e5\u8bdd\uff1a<\/b>\u8fd9\u4e9b\u6539\u52a8\uff0c\u6ca1\u6709\u4e00\u6761\u662f\u201c\u6211\u4eec\u8bbe\u5907\u66f4\u597d\u201d\uff0c\u90fd\u662f\u5f53\u5e74\u8e29\u7684\u5751\u6362\u6765\u7684\u3002\u628a\u552e\u540e\u7684\u95ee\u9898\u53cd\u8fc7\u6765\u5199\u8fdb\u8bbe\u8ba1\uff0c\u540e\u9762\u6bcf\u4e00\u6237\u5c31\u5c11\u8e29\u4e00\u4e2a\u5751\u3002\u8fd9\u4efd\u6e05\u5355\u7684\u5b8c\u6574\u7248\uff0c\u6536\u5728 <a href=\"https:\/\/longmai-nt.com\/?page_id=14963\">\u6696\u901a\u552e\u540e\u767d\u76ae\u4e66\uff08\u603b\u7eb2\uff09<\/a> \u7684\u9644\u5f55 D\u3002<\/div>\n\n<h2>\u5e38\u89c1\u95ee\u9898\uff08\u6210\u90fd\u672c\u5730\u7248\uff09<\/h2>\n<div class=\"lm-faq\">\n<details><summary>\u4e24\u8054\u4f9b\u51fa\u95ee\u9898\uff0c\u4e00\u5b9a\u662f\u4e3b\u673a\u574f\u4e86\u5417\uff1f<\/summary><p>\u591a\u6570\u4e0d\u662f\u3002\u4e24\u8054\u4f9b\u662f\u6c34\u7cfb\u7edf\uff0c\u4e0a\u95e8\u62a5\u4fee\u91cc\u66f4\u591a\u7684\u662f\u6c34\u529b\u5931\u8861\u3001\u6c14\u5835\u3001\u6389\u538b\u3001\u7ed3\u57a2\u3001\u8054\u52a8\u6ca1\u505a\u597d\u8fd9\u7c7b\"\u6c34\u7684\u95ee\u9898\"\uff0c\u4e3b\u673a\u672c\u8eab\u51fa\u95ee\u9898\u7684\u6bd4\u4f8b\u5e76\u4e0d\u9ad8\u3002\u6211\u4eec\u4f1a\u5148\u6309\u73b0\u8c61\u5b9a\u4f4d\u662f\u54ea\u4e00\u5c42\u7684\u95ee\u9898\uff0c\u518d\u51b3\u5b9a\u4fee\u54ea\u91cc\uff0c\u4e0d\u4f1a\u4e00\u4e0a\u6765\u5c31\u8ba9\u4f60\u6362\u4e3b\u673a\u3002<\/p><\/details>\n<details><summary>\u6709\u7684\u623f\u95f4\u70ed\u6709\u7684\u4e0d\u70ed\uff0c\u662f\u5730\u6696\u6ca1\u94fa\u597d\u5417\uff1f<\/summary><p>\u591a\u534a\u662f\u6c34\u529b\u5931\u8861\u6216\u90a3\u4e00\u8def\u7684\u56de\u8def\u8bbe\u8ba1\u95ee\u9898\uff0c\u4e0d\u662f\"\u6ca1\u94fa\u597d\"\u8fd9\u4e48\u7b80\u5355\u3002\u6c34\u4f1a\u4f18\u5148\u8d70\u963b\u529b\u5c0f\u7684\u90a3\u4e00\u8def\uff0c\u8fd1\u7aef\u628a\u6d41\u91cf\u62a2\u8d70\uff0c\u8fdc\u7aef\u5c31\u4e0d\u70ed\u3002\u901a\u5e38\u901a\u8fc7\u8c03\u8282\u5e73\u8861\u9600\u5c31\u80fd\u6539\u5584\uff1b\u5982\u679c\u662f\u56de\u8def\u592a\u957f\u3001\u7ba1\u5f84\u504f\u7ec6\uff0c\u5c31\u8981\u5c40\u90e8\u6539\u9020\u3002<\/p><\/details>\n<details><summary>\u538b\u529b\u8868\u4e00\u76f4\u5f80\u4e0b\u6389\uff0c\u662f\u4e0d\u662f\u6f0f\u6c34\u4e86\uff1f<\/summary><p>\u4e0d\u4e00\u5b9a\u3002\u5148\u6cc4\u538b\u6d4b\u8bd5\uff1a\u6cc4\u538b\u540e\u538b\u529b\u8fd8\u6389\uff0c\u591a\u534a\u662f\u771f\u6f0f\uff1b\u6cc4\u538b\u540e\u4e0d\u6389\u4e86\uff0c\u662f\u7cfb\u7edf\u8d85\u538b\uff0c\u6839\u5b50\u5728\u81a8\u80c0\u7f50\u5931\u6548\u2014\u2014\u6c34\u53d7\u70ed\u81a8\u80c0\u6ca1\u5904\u5bb9\u7eb3\uff0c\u538b\u529b\u5347\u9ad8\uff0c\u4ece\u6cc4\u538b\u9600\u6392\u51fa\u53bb\u3002\u8fd9\u4e24\u79cd\u5904\u7406\u65b9\u5f0f\u5b8c\u5168\u4e0d\u540c\uff0c\u6240\u4ee5\u8981\u5148\u4e0a\u95e8\u68c0\u6d4b\u5224\u65ad\u3002<\/p><\/details>\n<details><summary>\u7cfb\u7edf\u6709\u6c34\u6d41\u58f0\u3001\u6709\u566a\u97f3\uff0c\u600e\u4e48\u5904\u7406\uff1f<\/summary><p>\u5148\u6392\u6c14\uff0c\u591a\u6570\u54d7\u54d7\u58f0\u662f\u7ba1\u8def\u91cc\u7684\u7a7a\u6c14\u9020\u6210\u7684\u3002\u5982\u679c\u6392\u6c14\u540e\u8fd8\u6709\u6301\u7eed\u7684\u4f4e\u9891\u8f70\u9e23\uff0c\u8981\u67e5\u6c34\u6cf5\u9009\u578b\u548c\u7ba1\u5f84\u662f\u4e0d\u662f\u5339\u914d\uff1b\u672b\u7aef\u90fd\u5173\u4e86\u8fd8\u9707\uff0c\u8981\u68c0\u67e5\u538b\u5dee\u65c1\u901a\u3002\u8fd9\u7c7b\u95ee\u9898\u591a\u6570\u80fd\u5728\u8c03\u8bd5\u9636\u6bb5\u89e3\u51b3\uff0c\u524d\u63d0\u662f\u8bbe\u8ba1\u65f6\u628a\u6c34\u6cf5\u3001\u7ba1\u5f84\u3001\u65c1\u901a\u7b97\u5bf9\u3002<\/p><\/details>\n<details><summary>\u4e24\u8054\u4f9b\u7528\u4e86\u51e0\u5e74\u8d8a\u6765\u8d8a\u4e0d\u70ed\uff0c\u662f\u4ec0\u4e48\u539f\u56e0\uff1f<\/summary><p>\u5e38\u89c1\u662f\u6c34\u57a2\u548c\u8150\u8680\u4ea7\u7269\u628a\u7ba1\u8def\u3001\u6362\u70ed\u5668\u5835\u4e86\uff0c\u6d41\u91cf\u548c\u6362\u70ed\u90fd\u4e0b\u964d\u3002\u5904\u7406\u529e\u6cd5\u662f\u9010\u8def\u51b2\u6d17\u3001\u8865\u6c34\u5e76\u52a0\u6ce8\u7cfb\u7edf\u4fdd\u62a4\u5242\u3002\u60f3\u4ece\u6839\u4e0a\u5c11\u7ed3\u57a2\uff0c\u7ba1\u8def\u8981\u7edf\u4e00\u7528\u963b\u6c27\u7ba1\uff0c\u505c\u6696\u5b63\u505a\u6ee1\u6c34\u4fdd\u517b\u3002<\/p><\/details>\n<details><summary>\u70ed\u6c34\u548c\u5730\u6696\u7528\u540c\u4e00\u4e2a\u7cfb\u7edf\uff0c\u4f1a\u4e0d\u4f1a\u4e92\u76f8\u5f71\u54cd\uff1f<\/summary><p>\u4e24\u8054\u4f9b\u7684\u5236\u51b7\u5236\u70ed\u548c\"\u751f\u6d3b\u70ed\u6c34\"\u662f\u4e24\u56de\u4e8b\uff0c\u8bbe\u7f6e\u65f6\u5fc5\u987b\u5206\u6e05\u3002\u771f\u5b9e\u8c03\u8bd5\u91cc\u51fa\u73b0\u8fc7\u6c34\u6a21\u5757\u62a5\u4ee3\u7801 16\uff08\u672a\u88c5\u6362\u70ed\u6c34\u7bb1\u6c34\u6e29\u63a2\u5934\u3001\u5374\u6fc0\u6d3b\u4e86\u70ed\u6c34\u8bbe\u7f6e\uff09\u3002\u6240\u4ee5\u8c03\u8bd5\u65f6\uff0c\u529f\u80fd\u8bbe\u7f6e\u4e00\u5b9a\u8981\u548c\u5b9e\u9645\u5b89\u88c5\u7684\u786c\u4ef6\u5bf9\u5f97\u4e0a\u3002<\/p><\/details>\n<details><summary>\u6c34\u6cf5\u4e00\u5929\u5230\u665a\u5728\u8f6c\uff0c\u8d39\u7535\u5417\uff1f<\/summary><p>\u8d39\u7535\uff0c\u800c\u4e14\u662f\u767d\u8d39\u3002\u6b63\u5e38\u5e94\u8be5\u662f\u5ba4\u6e29\u5230\u4e86\u5c31\u505c\u4e3b\u673a\u3001\u5ef6\u65f6\u505c\u6c34\u6cf5\u3002\u5982\u679c\u6c34\u6cf5 24 \u5c0f\u65f6\u7a7a\u8f6c\uff0c\u8bf4\u660e\u8054\u52a8\u6ca1\u505a\u597d\u3002\u628a\"\u5ba4\u6e29\u2192\u6c34\u6cf5\u2192\u4e3b\u673a\"\u7684\u8054\u52a8\u903b\u8f91\u8865\u4e0a\u5e76\u8c03\u8bd5\uff0c\u8fd9\u90e8\u5206\u6d6a\u8d39\u5c31\u80fd\u7701\u6389\u3002<\/p><\/details>\n<details><summary>\u4e24\u8054\u4f9b\u6e05\u6d17\u4fdd\u517b\uff0c\u591a\u4e45\u505a\u4e00\u6b21\uff1f<\/summary><p>\u770b\u6c34\u8d28\u548c\u4f7f\u7528\u60c5\u51b5\u3002\u4e00\u822c\u5efa\u8bae\u6bcf\u5e74\u68c0\u67e5\u4e00\u6b21\u7cfb\u7edf\u6c34\u8d28\u548c Y \u578b\u8fc7\u6ee4\u5668\uff0c\u5165\u590f\u524d\u68c0\u67e5\u7ba1\u9053\u548c\u98ce\u673a\u76d8\u7ba1\u4fdd\u6e29\uff1b\u786c\u5ea6\u9ad8\u7684\u7247\u533a\u8981\u66f4\u5173\u6ce8\u7ed3\u57a2\u3002\u5177\u4f53\u5230\u4f60\u5bb6\uff0c\u6211\u4eec\u4e0a\u95e8\u65f6\u53ef\u4ee5\u6309\u6c34\u8d28\u548c\u8fd0\u884c\u5e74\u9650\u7ed9\u4e00\u4e2a\u4fdd\u517b\u5b89\u6392\u3002<\/p><\/details>\n<details><summary>\u4f60\u4eec\u4e0a\u95e8\u662f\u4fee\u597d\u518d\u8bf4\uff0c\u8fd8\u662f\u5148\u62a5\u4ef7\uff1f<\/summary><p>\u5148\u68c0\u6d4b\u3001\u540e\u62a5\u4ef7\uff0c\u4f60\u786e\u8ba4\u4e86\u518d\u5f00\u5de5\uff0c\u4e0d\u52a0\u4ef7\u3002\u539f\u5382\u914d\u4ef6\uff0c\u540c\u4e00\u95ee\u9898 6 \u4e2a\u6708\u5185\u514d\u8d39\u590d\u67e5\u3002\u4e0a\u95e8\u8d39\u6309\u533a\u57df\u6536\uff0c\u7ef4\u4fee\u548c\u4fdd\u517b\u6309\u9879\u76ee\u548c\u6570\u91cf\u8ba1\u8d39\uff0c199 \u5143\u4f1a\u5458\u4eab\u4f1a\u5458\u4ef7\u3002\u5b8c\u6574\u4ef7\u76ee\u89c1 <a href=\"https:\/\/longmai-nt.com\/?page_id=14057\">\u6210\u90fd\u6696\u901a\u552e\u540e\u670d\u52a1\u4ef7\u683c\u8868<\/a>\u3002<\/p><\/details>\n<\/div>\n\n<h2>\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<div class=\"lm-lead\">\n<b>\u552e\u540e\u8d1f\u8d23\u4eba\uff1a\u6768\u6676\u6676\u3000<a href=\"tel:15680075476\">15680075476<\/a><\/b>\uff08\u4e24\u8054\u4f9b \/ \u4e2d\u592e\u7a7a\u8c03 \/ \u5730\u6696 \/ \u6696\u6c14\u7247\u7ef4\u4fee\u4fdd\u517b\uff0c\u76f4\u63a5\u5bf9\u63a5\uff0c\u4e0d\u8f6c\u9500\u552e\uff09\n<\/div>\n<div class=\"lm-stores\">\n<div class=\"lm-store\">\n<b>\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97<\/b><br>\n\u5730\u5740\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<br>\n\u95e8\u5e97\u7535\u8bdd\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><br>\n<a href=\"https:\/\/uri.amap.com\/search?keyword=\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97&amp;city=\u6210\u90fd\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a<\/a>\u3000|\u3000<a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" rel=\"noopener\">\u5b98\u7f51<\/a>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n<\/div>\n<div class=\"lm-store\">\n<b>\u9f99\u8109\u6696\u901a\u00b7\u6210\u534e\u533a\u5e97\uff08\u5317\u5bcc\u68ee\uff09<\/b><br>\n\u5730\u5740\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<br>\n\u95e8\u5e97\u7535\u8bdd\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><br>\n<a href=\"https:\/\/uri.amap.com\/search?keyword=\u9f99\u8109\u6696\u901a\u6210\u534e\u533a\u5e97&amp;city=\u6210\u90fd\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a<\/a>\u3000|\u3000<a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" rel=\"noopener\">\u5b98\u7f51<\/a>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u6210\u534e\u533a\u5e97\uff08\u5317\u5bcc\u68ee\uff09\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n<\/div>\n<\/div>\n<p><b>\u8425\u4e1a\u65f6\u95f4<\/b>\uff1a\u5468\u4e00\u81f3\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u81f3\u5468\u65e5 10:00\u201319:00<\/p>\n<p><b>\u670d\u52a1\u8303\u56f4<\/b>\uff1a\u6210\u90fd\u5168\u57df\uff08\u9ad8\u65b0 \/ \u5929\u5e9c\u65b0\u533a \/ \u9526\u6c5f \/ \u9752\u7f8a \/ \u6b66\u4faf \/ \u6210\u534e \/ \u91d1\u725b \/ \u9f99\u6cc9 \/ \u53cc\u6d41 \/ \u6e29\u6c5f \/ \u90eb\u90fd\u7b49\uff09\u3002<\/p>\n<p><a class=\"lm-btn\" href=\"tel:15680075476\">\u9a6c\u4e0a\u53eb\u5e08\u5085\u4e0a\u95e8<\/a> <a class=\"lm-btn\" href=\"https:\/\/uri.amap.com\/search?keyword=\u9f99\u8109\u6696\u901a&amp;city=\u6210\u90fd\" target=\"_blank\" rel=\"noopener\">\u67e5\u6700\u8fd1\u95e8\u5e97<\/a><\/p>\n\n<h2>\u5ef6\u4f38\u9605\u8bfb<\/h2>\n<ul>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=13098\">\u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u6280\u672f\u767d\u76ae\u4e66\uff1a\u539f\u7406\u3001\u67b6\u6784\u3001\u9009\u578b\u3001\u5b9e\u6d4b<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=13115\">\u4ec0\u4e48\u662f\u4e8c\u8054\u4f9b\uff1f\u4e00\u5957\u7cfb\u7edf\uff0c\u590f\u5929\u5236\u51b7\u3001\u51ac\u5929\u5730\u6696<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u4e8c\u8054\u4f9b\u600e\u4e48\u9009\uff1a\u6c34\u673a vs \u6c1f\u673a<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=13151\">\u65e5\u7acb\u6c34\u5885\u9002\u6548\u679c\u4e0e\u80fd\u8017\u5b9e\u6d4b<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=14764\">\u65e5\u7acb\u6c34\u5885\u9002\u4ef7\u683c\u4e0e\u6210\u5957\u9884\u7b97<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=13112\">\u6210\u90fd\u5730\u6696\u6e05\u6d17\u7ef4\u4fee\uff1a\u4e0d\u70ed\u3001\u6362\u6c34\u3001\u6392\u6c14<\/a><\/li>\n  <li><a href=\"https:\/\/longmai-nt.com\/?page_id=13109\">\u6210\u90fd\u58c1\u6302\u7089\u7ef4\u4fee\u4fdd\u517b\uff1a\u4e0d\u70b9\u706b\u3001\u62a5\u9519\u3001\u6f0f\u6c34\uff08\u91c7\u6696\u70ed\u6e90\uff09<\/a><\/li>\n  <\/ul>\n<div class=\"lm-series-nav\" style=\"margin:30px 0 6px;padding:18px 20px;border:1px solid #e6cfa6;border-radius:10px;background:#fffdf6;\">\n  <p style=\"margin:0 0 10px;font-weight:700;color:#8a5a00;\">\u6696\u901a\u552e\u540e\u767d\u76ae\u4e66\u7cfb\u5217\uff08\u6309\u7cfb\u7edf\u5206\u518c\uff0c\u4ece\u771f\u5b9e\u552e\u540e\u53cd\u63a8\u8bbe\u8ba1\uff09<\/p>\n  <ul style=\"margin:0;padding-left:20px;line-height:2.1;\">\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=14963\" title=\"\u6696\u901a\u552e\u540e\u767d\u76ae\u4e66\u603b\u7eb2\">\u6696\u901a\u552e\u540e\u767d\u76ae\u4e66\u603b\u7eb2\uff1a\u5404\u7cfb\u7edf\u5171\u901a\u7684\u6545\u969c\u4e0e\u7ef4\u4fdd\u539f\u7406<\/a><\/li>\n        <li><a href=\"https:\/\/longmai-nt.com\/?page_id=15020\" title=\"\u4e2d\u592e\u7a7a\u8c03\u552e\u540e\u767d\u76ae\u4e66\">\u4e2d\u592e\u7a7a\u8c03\u552e\u540e\u767d\u76ae\u4e66\uff1a\u4e0d\u5236\u51b7\u3001\u6ef4\u6c34\u3001\u9709\u5473\u3001\u566a\u97f3\u600e\u4e48\u67e5<\/a><\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=15021\" title=\"\u5730\u6696\u552e\u540e\u767d\u76ae\u4e66\">\u5730\u6696\u552e\u540e\u767d\u76ae\u4e66\uff1a\u4e0d\u70ed\u3001\u6389\u538b\u3001\u6c34\u53d1\u9ed1\u7684\u771f\u5b9e\u6839\u56e0<\/a><\/li>\n  <\/ul>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u5f88\u591a\u4eba\u628a\u4e24\u8054\u4f9b\u7406\u89e3\u6210\"\u4e00\u53f0\u4e3b\u673a\u52a0\u51e0\u6839\u7ba1\u5b50 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-14964","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u4e24\u8054\u4f9b\u552e\u540e\u4fdd\u517b\u767d\u76ae\u4e66\uff1a\u4e24\u8054\u4f9b\u7684\u6545\u969c\u5927\u591a\u4e0d\u51fa\u5728\u4e3b\u673a\uff0c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u3002\u8bb2\u6e05\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u63a7\u5236\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\u3001\u4fdd\u517b\u5468\u671f\u3001\u8bbe\u5907\u5224\u5e9f\u5e74\u9650\uff0c\u5f15\u7528 GB 50736-2012\u3001JGJ 142-2012\uff0c\u7ed3\u8bba\u53ef\u81ea\u884c\u590d\u7b97\u6838\u9a8c\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=14964\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u4e24\u8054\u4f9b\u552e\u540e\u4fdd\u517b\u767d\u76ae\u4e66\uff1a\u4e24\u8054\u4f9b\u7684\u6545\u969c\u5927\u591a\u4e0d\u51fa\u5728\u4e3b\u673a\uff0c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u3002\u8bb2\u6e05\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u63a7\u5236\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\u3001\u4fdd\u517b\u5468\u671f\u3001\u8bbe\u5907\u5224\u5e9f\u5e74\u9650\uff0c\u5f15\u7528 GB 50736-2012\u3001JGJ 142-2012\uff0c\u7ed3\u8bba\u53ef\u81ea\u884c\u590d\u7b97\u6838\u9a8c\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=14964\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-15T09:23:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964\",\"name\":\"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-nanfusen-store.jpg\",\"datePublished\":\"2026-10-14T08:00:11+00:00\",\"dateModified\":\"2026-10-15T09:23:58+00:00\",\"description\":\"\u6210\u90fd\u4e24\u8054\u4f9b\u552e\u540e\u4fdd\u517b\u767d\u76ae\u4e66\uff1a\u4e24\u8054\u4f9b\u7684\u6545\u969c\u5927\u591a\u4e0d\u51fa\u5728\u4e3b\u673a\uff0c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u3002\u8bb2\u6e05\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u63a7\u5236\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\u3001\u4fdd\u517b\u5468\u671f\u3001\u8bbe\u5907\u5224\u5e9f\u5e74\u9650\uff0c\u5f15\u7528 GB 50736-2012\u3001JGJ 142-2012\uff0c\u7ed3\u8bba\u53ef\u81ea\u884c\u590d\u7b97\u6838\u9a8c\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-nanfusen-store.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/gw-lmnt-nanfusen-store.jpg\",\"width\":1240,\"height\":538},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=14964#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u4e24\u8054\u4f9b\u552e\u540e\u4fdd\u517b\u767d\u76ae\u4e66\uff1a\u4e24\u8054\u4f9b\u7684\u6545\u969c\u5927\u591a\u4e0d\u51fa\u5728\u4e3b\u673a\uff0c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u3002\u8bb2\u6e05\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u63a7\u5236\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\u3001\u4fdd\u517b\u5468\u671f\u3001\u8bbe\u5907\u5224\u5e9f\u5e74\u9650\uff0c\u5f15\u7528 GB 50736-2012\u3001JGJ 142-2012\uff0c\u7ed3\u8bba\u53ef\u81ea\u884c\u590d\u7b97\u6838\u9a8c\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=14964","og_locale":"zh_CN","og_type":"article","og_title":"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u4e24\u8054\u4f9b\u552e\u540e\u4fdd\u517b\u767d\u76ae\u4e66\uff1a\u4e24\u8054\u4f9b\u7684\u6545\u969c\u5927\u591a\u4e0d\u51fa\u5728\u4e3b\u673a\uff0c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u3002\u8bb2\u6e05\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u63a7\u5236\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\u3001\u4fdd\u517b\u5468\u671f\u3001\u8bbe\u5907\u5224\u5e9f\u5e74\u9650\uff0c\u5f15\u7528 GB 50736-2012\u3001JGJ 142-2012\uff0c\u7ed3\u8bba\u53ef\u81ea\u884c\u590d\u7b97\u6838\u9a8c\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=14964","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-15T09:23:58+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=14964","url":"https:\/\/longmai-nt.com\/?page_id=14964","name":"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=14964#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=14964#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg","datePublished":"2026-10-14T08:00:11+00:00","dateModified":"2026-10-15T09:23:58+00:00","description":"\u6210\u90fd\u4e24\u8054\u4f9b\u552e\u540e\u4fdd\u517b\u767d\u76ae\u4e66\uff1a\u4e24\u8054\u4f9b\u7684\u6545\u969c\u5927\u591a\u4e0d\u51fa\u5728\u4e3b\u673a\uff0c\u51fa\u5728\u6c34\u8def\u8bbe\u8ba1\u548c\u8054\u52a8\u903b\u8f91\u3002\u8bb2\u6e05\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u63a7\u5236\u3001\u6545\u969c\u4ee3\u7801\u901f\u67e5\u3001\u4fdd\u517b\u5468\u671f\u3001\u8bbe\u5907\u5224\u5e9f\u5e74\u9650\uff0c\u5f15\u7528 GB 50736-2012\u3001JGJ 142-2012\uff0c\u7ed3\u8bba\u53ef\u81ea\u884c\u590d\u7b97\u6838\u9a8c\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=14964#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=14964"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=14964#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg","width":1240,"height":538},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=14964#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14964","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14964"}],"version-history":[{"count":6,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14964\/revisions"}],"predecessor-version":[{"id":15118,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/14964\/revisions\/15118"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14964"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}