{"id":15298,"date":"2026-10-16T17:13:55","date_gmt":"2026-10-16T09:13:55","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=15298"},"modified":"2026-10-17T13:52:50","modified_gmt":"2026-10-17T05:52:50","slug":"%e4%b8%89%e5%b2%94%e6%b9%96%e4%b8%96%e8%8c%82%e4%ba%91%e6%b9%96%c2%b7%e5%85%a8%e5%b1%8b%e4%ba%94%e6%81%92%e4%b8%8e%e6%99%ba%e8%83%bd%e5%ae%b6%e5%b1%85%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=15298","title":{"rendered":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09"},"content":{"rendered":"\n<style>\n  :root{--ink:#111827;--gray:#6b7280;--line:#e5e7eb;--accent:#0f6ecf;--accent2:#c9382b;--bg:#f6f8fb;--ok:#0a7a3d;--warnbg:#fff7e6;--warnline:#e0a800}\n  *{box-sizing:border-box;margin:0;padding:0}\n  body{font-family:\"Microsoft YaHei\",\"PingFang SC\",sans-serif;color:var(--ink);background:#fff;font-size:14.5px;line-height:1.75}\n  .wrap{max-width:880px;margin:0 auto;padding:28px 22px 60px}\n  .dochead{border-bottom:3px solid var(--accent);padding-bottom:14px;margin-bottom:22px}\n  .dochead .brand{font-size:13px;color:var(--gray);letter-spacing:2px}\n  .dochead h2{font-size:23px;margin:6px 0 4px;line-height:1.4}\n  .dochead .meta{font-size:12.5px;color:var(--gray)}\n  .step-tag{display:inline-block;background:var(--accent);color:#fff;font-size:12px;padding:2px 10px;border-radius:3px;margin:26px 0 8px;letter-spacing:1px}\n  h3{font-size:17.5px;margin:4px 0 10px}\n  h4{font-size:15px;margin:14px 0 6px}\n  p{margin:7px 0}\n  table{width:100%;border-collapse:collapse;margin:10px 0;font-size:13px}\n  th{background:#eef4fb;text-align:left}\n  th,td{border:1px solid var(--line);padding:7px 9px;vertical-align:top}\n  td.k{font-weight:700;white-space:nowrap}\n  td.why{color:var(--gray);font-size:12.5px}\n  .note{background:var(--bg);border-left:4px solid var(--accent);padding:12px 14px;border-radius:0 8px 8px 0;margin:12px 0;font-size:13.5px}\n  .warn{background:var(--warnbg);border-left:4px solid var(--warnline);padding:12px 14px;border-radius:0 8px 8px 0;margin:12px 0;font-size:13.5px}\n  .okbox{background:#f0f9f1;border-left:4px solid var(--ok);padding:12px 14px;border-radius:0 8px 8px 0;margin:12px 0;font-size:13.5px}\n  .imgbox{margin:12px 0}\n  .imgbox img{width:100%;display:block;border:1px solid var(--line);border-radius:8px;background:#fff;object-fit:contain}\n  .imgbox.tall img{max-height:340px}\n  .imgbox b{display:block;font-size:12px;color:var(--gray);margin-top:5px;font-weight:400}\n  .grid2{display:grid;grid-template-columns:1fr 1fr;gap:12px}\n  .grid3{display:grid;grid-template-columns:repeat(3,1fr);gap:10px}\n  .gal img{width:100%;height:160px;object-fit:cover;border:1px solid var(--line);border-radius:8px;display:block}\n  .gal-ht img{height:400px;object-fit:contain;background:#fff}\n  @media(max-width:640px){.grid2,.grid3{grid-template-columns:1fr}}\n  .card{border:1px solid var(--line);border-radius:10px;padding:13px 15px;background:#fff}\n  .card b{display:block;margin-bottom:4px}\n  .card span{font-size:13px;color:var(--gray)}\n  details{border:1px solid var(--line);border-radius:8px;margin:10px 0;background:#fff}\n  details summary{cursor:pointer;padding:11px 14px;font-weight:700;background:#f3f6fb;border-radius:8px;font-size:13.5px}\n  details[open] summary{border-radius:8px 8px 0 0}\n  details .inner{padding:12px 14px}\n  .stores{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:12px 0}\n  .stores .s{border:1px solid var(--line);border-radius:10px;overflow:hidden}\n  .stores .s .pic{height:130px;overflow:hidden}\n  .stores .s .pic img{width:100%;height:100%;object-fit:cover;display:block}\n  .stores .s .info{padding:10px 12px;font-size:13px}\n  .stores .s .info b{display:block;margin-bottom:3px}\n  .linklist{margin:12px 0}\n  .linklist .lk{border:1px solid var(--line);border-radius:10px;padding:11px 14px;margin:8px 0;background:#fff}\n  .linklist .lk a{color:var(--accent);font-weight:700;text-decoration:none}\n  .linklist .lk span{display:block;font-size:13px;color:var(--gray);margin:3px 0 2px}\n  .linklist .lk i{display:block;font-style:normal;font-size:11.5px;color:var(--gray);word-break:break-all}\n  .ph{color:#b45309;font-weight:700}\n  .foot{margin-top:34px;padding-top:14px;border-top:1px solid var(--line);font-size:12px;color:var(--gray)}\n  .kv{display:grid;grid-template-columns:110px 1fr;font-size:13.5px}\n  .kv div{padding:5px 0;border-bottom:1px dashed var(--line)}\n  ul,ol{margin:6px 0 6px 22px}\n  li{margin:3px 0}\n  .price-table td:nth-child(2),.price-table th:nth-child(2){text-align:right}\n<\/style>\n<\/head>\n<body>\n<div class=\"wrap\">\n\n  <div class=\"dochead\">\n    <div class=\"brand\">\u9f99\u8109\u6696\u901a \u00b7 LONMAI HVAC \u00b7 \u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546<\/div>\n    <h2>\u4e1a\u4e3b\u5bb6 \u00b7 \u6210\u90fd\u67d0\u751f\u6001\u6e56\u533a\u4e09\u5c42\u8054\u6392\u522b\u5885<br>\u5168\u5c4b\u4e94\u6052\u4e0e\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u5b9e\u666f\u65b9\u6848\uff08\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff09<\/h2>\n    <div class=\"meta\">\u65b9\u6848\u7f16\u53f7\uff1aFA-LM-001\uff08\u6b63\u5f0f\u7f16\u53f7\u4ee5\u5408\u540c\u4e3a\u51c6\uff09\uff5c\u987e\u95ee\uff1a\u8303\u4e3d\u5982\uff5c\u51fa\u5177\u65e5\u671f\uff1a2026-10-16\uff5c\u6709\u6548\u671f\uff1a30 \u5929<\/div>\n  <\/div>\n\n  <!-- \u53cc\u8303\u7574\u5b9a\u4f4d -->\n  <div class=\"note\" style=\"border-left-color:#c9382b\">\n    <b>\u672c\u65b9\u6848\u843d\u5728\u54ea\u4e24\u6761\u7ebf\u4e0a\uff08\u53cc\u8303\u7574\uff0c\u522b\u6df7\u4e3a\u4e00\u8c08\uff09<\/b><br>\n    \u8fd9\u5957\u4ea4\u4ed8\u540c\u65f6\u8986\u76d6\u4e86\u4e24\u4e2a\u5e38\u88ab\u6df7\u4e3a\u4e00\u8c08\u7684\u8303\u7574\uff0c\u8bf7\u5206\u5f00\u770b\uff1a<br>\n    \u2460 <b>\u4e24\u8054\u4f9b\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/b>\uff1a\u4e00\u53f0\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161 \u4e3b\u673a\uff0c\u590f\u5929\u5e26\u7a7a\u8c03\u3001\u51ac\u5929\u5e26\u5730\u6696\uff08\u6c34\u6a21\u5757\u4ece\u4e3b\u673a\u53d6\u70ed\uff09\uff0c\u5c11\u4e00\u53f0\u58c1\u6302\u7089\u3002\u8def\u7ebf\u603b\u7eb2\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=15302\">\u300a\u6210\u90fd\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u65b9\u6848\u300b<\/a>\u3002<br>\n    \u2461 <b>\u4e94\u6052 + \u667a\u80fd\u63a7\u5236<\/b>\uff1a\u5728\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u3001\u65b0\u98ce\u3001\u96c6\u63a7\u5c4f\u4e4b\u4e0a\uff0c\u505a\u5230\u6e29\u5ea6\/\u6e7f\u5ea6\/\u6d01\u51c0\/\u5b89\u9759\/\u667a\u80fd\u7684\u4e94\u6052\u4f53\u9a8c\uff0c\u5e76\u4e00\u5757\u5c4f\u7edf\u4e00\u7ba1\u95e8\u7a97\u706f\u5149\u3002\u8be6\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=13292\">\u300a\u4e94\u6052\u207a\u7cfb\u7edf\u767d\u76ae\u4e66\u300b<\/a>\u3001<a href=\"https:\/\/longmai-nt.com\/?page_id=657\">\u300a\u5c45\u5bb6\u73af\u5883\u4e94\u6052\u6307\u5357\u300b<\/a>\u3002<br>\n    \u4e24\u4ef6\u4e8b\u90fd\u505a\u4e86\uff0c\u4f46\u903b\u8f91\u4e0d\u540c\uff1a\u4e24\u8054\u4f9b\u89e3\u51b3\"\u51b7\u70ed\u6e90\u600e\u4e48\u5408\u4e8c\u4e3a\u4e00\"\uff0c\u4e94\u6052+\u667a\u80fd\u89e3\u51b3\"\u4f4f\u8fdb\u53bb\u8212\u4e0d\u8212\u670d\u3001\u597d\u4e0d\u597d\u7ba1\"\u3002\n  <\/div>\n\n  <!-- \u4e00\u3001\u9700\u6c42\u8fd8\u539f -->\n  <span class=\"step-tag\">\u4e00 \u00b7 \u60a8\u7684\u8981\u6c42\uff0c\u6211\u4eec\u539f\u6837\u8bb0\u4e0b<\/span>\n  <h3>\u8fd9\u4efd\u65b9\u6848\u53ea\u89e3\u51b3\u60a8\u5bb6\u7684\u4e8b<\/h3>\n  <p>\u8ddf\u60a8\u5f53\u9762\u804a\u8fc7\u4e4b\u540e\uff0c\u6211\u4eec\u628a\u60a8\u7684\u8981\u6c42\u4e00\u6761\u6761\u8bb0\u4e0b\u6765\uff0c\u65b9\u6848\u5c31\u7167\u8fd9\u51e0\u6761\u505a\uff1a<\/p>\n  <div class=\"kv\">\n    <div>\u8eab\u4f53\u60c5\u51b5<\/div><div>\u6709\u6162\u963b\u80ba\u3001\u9f3b\u708e\u7b49\u547c\u5438\u9053\u57fa\u7840\u75c5\u2014\u2014<b>\u7a7a\u6c14\u662f\u7b2c\u4e00\u4f4d\u7684<\/b>\uff1a\u6e29\u6e7f\u5ea6\u8981\u7a33\u3001\u8981\u80fd\u9664\u6e7f\u3001\u8981\u6362\u6c14\u3001\u8981\u51c0\u5316<\/div>\n    <div>\u4e24\u5957\u623f<\/div><div>\u2460\u6210\u90fd\u67d0\u751f\u6001\u6e56\u533a\uff08\u4e09\u533a2\u680b2\u53f7\uff09\u4e09\u5c42\u8054\u6392\u522b\u5885\uff1a\u7a7a\u8c03\uff0b\u5730\u6696\uff0b\u65b0\u98ce\uff0b\u5168\u5c4b\u667a\u80fd\uff0c\u51ac\u907f\u973e\u3001\u590f\u907f\u6691\uff1b\u2461\u8d35\u5dde\u67d0\u5730\u907f\u6691\u623f\uff1a\u590f\u5929\u4e8c\u5341\u591a\u5ea6\u4e0d\u7528\u7a7a\u8c03\uff0c\u53ea\u89e3\u51b3<b>\u5ba4\u5185\u7a7a\u6c14\u51c0\u5316\u4e0e\u65b0\u98ce<\/b>\uff08\u53e6\u51fa\u65b9\u6848\uff0c\u89c1\u7b2c\u4e5d\u8282\uff09<\/div>\n    <div>\u5c45\u4f4f\u8282\u594f<\/div><div>\u6bcf\u5e74\u5927\u6982\u4f4f 5\uff5e6 \u4e2a\u6708\uff0c\u957f\u671f\u7a7a\u7f6e\u2014\u2014\u7cfb\u7edf\u8981\u7ecf\u5f97\u8d77\"\u957f\u65f6\u95f4\u4e0d\u7528\u4e00\u5f00\u5c31\u6b63\u5e38\"<\/div>\n    <div>\u54c1\u724c\u8fb9\u754c<\/div><div>\u53ea\u8003\u8651\u65e5\u7acb\u3001\u5927\u91d1\uff0c\u66f4\u504f\u5411\u65e5\u7acb\u2014\u2014\u770b\u4e2d\u7684\u662f\u767e\u5e74\u65e5\u4f01\u7684\u6280\u672f\u5e95\u5b50\u548c\u5e02\u573a\u53e3\u7891<\/div>\n    <div>\u5168\u5c4b\u667a\u80fd<\/div><div>\u5df2\u5b9a\u7687\u6d3e\u7535\u52a8\u9690\u85cf\u5f0f\u95e8\u7a97\uff08\u5e26\u96e8\u611f\u81ea\u52a8\u5173\u7a97\uff09\uff0c\u5e0c\u671b\u95e8\u7a97\u3001\u706f\u5149\u3001\u7a97\u5e18\u3001\u5b89\u9632\u548c\u7a7a\u8c03\u5730\u6696\u65b0\u98ce<b>\u4e00\u5757\u5c4f\u7edf\u4e00\u7ba1<\/b>\uff0c\u4e0d\u518d\u5806\u534e\u4e3a\u3001\u5c0f\u7c73\u3001\u7eff\u7c73\u51e0\u4e2a\u4e92\u4e0d\u76f8\u901a\u7684\u4e2d\u63a7<\/div>\n    <div>\u9884\u7b97<\/div><div>\u539f\u8ba1\u5212\u7ea6 8 \u4e07\u505a\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u96c6\u63a7\uff1b\u542c\u5b8c\u4e09\u7ba1\u5236\u3001\u65b0\u98ce\u3001\u96c6\u63a7\u7684\u5b8c\u6574\u914d\u7f6e\u540e\u660e\u786e\u8868\u6001\"\u4e0d\u80fd\u5c06\u5c31\"\u2014\u2014\u672c\u65b9\u6848\u6309\u5b8c\u6574\u914d\u7f6e\u5217\u660e\u6bcf\u4e00\u5206\u94b1\uff0c\u4f18\u60e0\u5f53\u9762\u8c08<\/div>\n  <\/div>\n  <h4 style=\"margin-top:20px\">\u60a8\u5bb6\u7684\u4e09\u5f20\u6237\u578b\u56fe\uff08\u88c5\u4fee\u8bbe\u8ba1\u5df2\u6807\u6ce8\u667a\u80fd\u70b9\u4f4d\uff09<\/h4>\n  <div class=\"grid3 gal gal-ht\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-yl.jpg\" alt=\"\u4e00\u697c\u6237\u578b\u56fe\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-el.jpg\" alt=\"\u4e8c\u697c\u6237\u578b\u56fe\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-sl.jpg\" alt=\"\u4e09\u697c\u6237\u578b\u56fe\">\n  <\/div>\n  <div class=\"imgbox\" style=\"margin-top:4px\"><b style=\"margin-top:0\">\u25b2 \u6210\u90fd\u67d0\u751f\u6001\u6e56\u533a\u4e00\u697c\uff0f\u4e8c\u697c\uff0f\u4e09\u697c\u6237\u578b\u56fe\u3002\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u5c31\u7167\u8fd9\u4e09\u5f20\u56fe\u9010\u95f4\u5206\u533a\uff1b\u56fe\u4e0a\u5df2\u6807\u6ce8\u7684\u95e8\u7a97\u81ea\u52a8\u5668\u3001\u611f\u5e94\u706f\u3001\u9632\u6454\u62a5\u8b66\u5668\u3001\u6c34\u6d78\u536b\u58eb\u7b49\u70b9\u4f4d\uff0c\u52d8\u6d4b\u65f6\u9010\u9879\u6838\u5bf9\u3001\u9010\u9879\u62a5\u4ef7<\/b><\/div>\n\n  <!-- \u4e8c\u3001\u7cfb\u7edf\u603b\u89c8 -->\n  <span class=\"step-tag\">\u4e8c \u00b7 \u6574\u5957\u7cfb\u7edf\u957f\u4ec0\u4e48\u6837<\/span>\n  <h3>\u4e00\u53f0\u4e3b\u673a\u5e26\u4e09\u4ef6\u4e8b\uff1a\u7a7a\u8c03\u3001\u5730\u6696\u3001\u70ed\u6c34\u63a5\u53e3\uff0c\u518d\u52a0\u65b0\u98ce\u548c\u4e00\u5757\u603b\u63a7\u5c4f<\/h3>\n  <div class=\"imgbox tall\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-vamzrftsllgxtylt-1.jpg\" alt=\"\u65e5\u7acbVAM\u5c0a\u777f\u5206\u4f53\u5f0f\u4e24\u8054\u4f9b\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u4e00\u53f0\u6c34\u6a21\u5757\uff09\"><b>\u25b2 \u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u539f\u7406\uff1a\u6c1f\u7cfb\u7edf\u7a7a\u8c03\u7167\u5e38\u8d70\u6c1f\uff1b\u5730\u6696\u7684\u70ed\u7531\u4e00\u53f0\u6c34\u6a21\u5757\u4ece\u4e3b\u673a\u53d6\uff0c\u70ed\u6c34\u518d\u8fdb\u5730\u6696\u76d8\u7ba1\uff08\u5382\u5bb6\u56fe\u6ce8\uff1a\u6c34\u7cfb\u7edf\u4e3b\u7ba1\u4e0d\u5b9c\u5c0f\u4e8e De40\uff0c\u4e0e\u672c\u65b9\u6848\u914d\u7f6e\u4e00\u81f4\uff09<\/b><\/div>\n  <table>\n    <tr><th>\u7cfb\u7edf<\/th><th>\u9009\u7684\u4e1c\u897f<\/th><th>\u5bf9\u60a8\u5bb6\u7684\u610f\u4e49<\/th><\/tr>\n    <tr><td class=\"k\">\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548\u2161 \u5916\u673a \uff0b \u6e29\u6e7f\u53cc\u63a7\u4e09\u7ba1\u5236\u5185\u673a 6 \u53f0<\/td><td>\u9664\u6e7f\u4e0d\u964d\u6e29\u3001\u5fae\u98ce\u51c0\u5316\u6a21\u5f0f\uff0c\u4e13\u4e3a\u547c\u5438\u9053\u654f\u611f\u7684\u4eba\u9009<\/td><\/tr>\n    <tr><td class=\"k\">\u5730\u6696<\/td><td>\u6c34\u6a21\u5757\u6362\u70ed \uff0b \u4f1f\u661f\u5730\u6696 132\u33a1\uff08dn20 \u76d8\u7ba1\uff09<\/td><td>\u51ac\u5929\u811a\u5e95\u6696\uff0c\u6c34\u6a21\u5757\u4ece\u4e3b\u673a\u53d6\u70ed\uff0c\u4e0d\u7528\u518d\u4e70\u58c1\u6302\u7089<\/td><\/tr>\n    <tr><td class=\"k\">\u65b0\u98ce<\/td><td>\u65e5\u7acb\u5929\u51c0 KPI-3521\uff08\u4e00\uff0b\u4e8c\u5c42\uff09\uff0b KPI-1521\uff08\u4e09\u5c42\uff09<\/td><td>\u5173\u7a97\u4e5f\u6709\u65b0\u9c9c\u7a7a\u6c14\uff0cPM2.5\u3001CO2\u3001\u5f02\u5473\u4e00\u8d77\u7ba1<\/td><\/tr>\n    <tr><td class=\"k\">\u5168\u5c4b\u667a\u80fd<\/td><td>\u65e5\u7acb\u667a\u6167\u96c6\u63a7\u5c4f\uff08CCS-160R1D\uff09\uff0b \u5168\u5c4b\u5168\u611f\u7cfb\u7edf<\/td><td>\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u7687\u6d3e\u95e8\u7a97\u3001\u706f\u5149\u7a97\u5e18\u4e00\u5757\u5c4f\u7ba1\uff0c\u56db\u5ddd\u8bdd\u8bed\u97f3\u79bb\u7ebf\u53ef\u7528<\/td><\/tr>\n  <\/table>\n\n  <!-- \u4e09\u3001\u7a7a\u8c03\u914d\u7f6e -->\n  <span class=\"step-tag\">\u4e09 \u00b7 \u7a7a\u8c03\u600e\u4e48\u914d\u7684\uff1a\u9010\u95f4\u7b97\uff0c\u4e0d\u662f\u62cd\u8111\u888b<\/span>\n  <h3>\u4e09\u5c42\u516d\u4e2a\u623f\u95f4\uff0c\u6bcf\u95f4\u90fd\u6709\u4f9d\u636e<\/h3>\n  <table>\n    <thead><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef\u33a1<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cfW<\/th><th>\u8bbe\u8ba1\u51b7\u6307\u6807<\/th><th>\u5b9e\u9645\u51b7\u6307\u6807<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e00\u5c42<\/td><td>\u5ba2\u9910\u5385\uff0b\u5f00\u653e\u5f0f\u53a8\u623f<\/td><td>64<\/td><td>RPIZ-71FSVN2QB\/PC \uff0b RCIS-22FSCN1QD\uff08\u5d4c\u5165\u5f0f\u53a8\u623f\u4e13\u7528\u673a\uff09<\/td><td>7,100\uff0b2,200<\/td><td>120<\/td><td>145<\/td><\/tr>\n      <tr><td>\u4e8c\u5c42<\/td><td>\u5367\u5ba41<\/td><td>13.9<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2,200<\/td><td>120<\/td><td>158<\/td><\/tr>\n      <tr><td>\u4e8c\u5c42<\/td><td>\u516c\u533a\uff08\u6311\u9ad86\u7c73\uff09<\/td><td>20<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>3,200<\/td><td>120<\/td><td>160<\/td><\/tr>\n      <tr><td>\u4e09\u5c42<\/td><td>\u5367\u5ba41<\/td><td>19.6<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>3,200<\/td><td>120<\/td><td>163<\/td><\/tr>\n      <tr><td>\u4e09\u5c42<\/td><td>\u5367\u5ba42<\/td><td>9<\/td><td>RPIZ-18FSVN2QB\/PC<\/td><td>1,800<\/td><td>120<\/td><td>200<\/td><\/tr>\n      <tr><td colspan=\"3\"><b>\u5408\u8ba1 126.5\u33a1\uff08\u6311\u9ad8\u6298\u7b97\u7ea6 149\u33a1\uff09<\/b><\/td><td>6 \u53f0<\/td><td><b>19,700<\/b><\/td><td colspan=\"2\">\u8fde\u63a5\u7387 <b>123.1%<\/b>\uff08\u5408\u89c4\u533a\u95f4 50%\u2013130%\uff09<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"note\"><b>\u4e8c\u5c42\u516c\u533a\u6311\u9ad8 6 \u7c73\u662f\u600e\u4e48\u7b97\u7684\uff1f<\/b>\u516c\u533a\u5730\u9762 20\u33a1\uff0c\u5c42\u9ad8 6 \u7c73\uff0c\u662f\u666e\u901a\u5c42\u9ad8\u7684\u4e24\u500d\u591a\u2014\u2014\u6309\u4f53\u79ef\u6298\u7b97\uff0c\u8fd9\u4e00\u95f4\u7684\u51b7\u70ed\u8d1f\u8377\u76f8\u5f53\u4e8e 43\u33a1 \u7684\u5e73\u5c42\u3002\u591a\u51fa\u6765\u7684\u7ea6 2,700W \u6ca1\u6709\u5355\u538b\u5728\u4e00\u53f0\u673a\u5668\u4e0a\uff0c\u800c\u662f\u644a\u8fdb\u5168\u5c4b\u4e00\u8d77\u7b97\uff1a\u6298\u7b97\u540e\u5168\u5c4b\u7ea6 149\u33a1\uff0c\u5185\u673a\u603b\u51b7\u91cf 19,700W\uff0c\u5e73\u5747\u6bcf\u5e73\u7c73 132W\uff0c\u6bd4 120 \u7684\u8bbe\u8ba1\u6307\u6807\u591a\u7559\u4e00\u6210\u2014\u2014\u6311\u7a7a\u90a3\u95f4\u7684\u51b7\u70ed\u5c31\u662f\u4ece\u8fd9\u91cc\u8865\u7684\u3002<\/div>\n  <div class=\"imgbox tall\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-rlqwqg2-0xtylt.png\" alt=\"\u65e5\u7acb\u5168\u5c4b\u5168\u611f2.0\u7cfb\u7edf\u539f\u7406\u56fe\"><b>\u25b2 \u5c0a\u777f\u5168\u6548\u4e94\u6052\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u65e5\u7acb\u5168\u5c4b\u5168\u611f 2.0\uff09\uff1a\u5916\u673a RAS-160FSXPN5Q\uff0816kW \u5236\u51b7 \/ 18kW \u5236\u70ed\uff0c\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c-25\u2103 \u6b63\u5e38\u542f\u52a8\uff09\u5e26\u7740\u5185\u673a\u3001\u6c34\u6a21\u5757\u3001\u65b0\u98ce\u3001\u4e2d\u63a7\u5c4f\uff0c\u4e00\u5957\u7cfb\u7edf\u7ba1\u5168\u5c4b<\/b><\/div>\n  <div class=\"note\"><b>\u4e00\u5c42\u5ba2\u9910\u5385\u4e3a\u4ec0\u4e48\u591a\u914d\u4e00\u53f0\u53a8\u623f\u4e13\u7528\u673a\uff1f<\/b>\u60a8\u5bb6\u5f00\u653e\u5f0f\u53a8\u623f\u8ddf\u9910\u5385\u8fde\u6210\u4e00\u4f53\uff0c\u7092\u83dc\u7684\u6cb9\u70df\u4f1a\u5f80\u5ba2\u9910\u5385\u98d8\uff0c\u8fd9\u4e00\u7247\u53c8\u6709\u70b9\u5f53\u897f\u6652\u3002\u6240\u4ee5\u6211\u4eec\u5efa\u8bae\u5728\u53a8\u623f\u52a0\u4e00\u53f0<b>\u5d4c\u5165\u5f0f\u53a8\u623f\u4e13\u7528\u673a RCIS-22FSCN1QD<\/b>\uff1a\u673a\u5668\u6309\u6cb9\u70df\u5de5\u51b5\u505a\u4e86\u9632\u6cb9\u70df\u8bbe\u8ba1\uff0c\u897f\u6652\u70ed\u7684\u65f6\u5019\u5355\u72ec\u5f00\u5b83\u5c31\u538b\u5f97\u4f4f\uff0c\u4e0d\u7528\u628a\u6574\u53f0\u5927\u673a\u5668\u62c9\u8d77\u6765\u2014\u2014\u8fd9\u5c31\u662f\u5b83\u8ddf\u5ba2\u9910\u5385\u4e3b\u5185\u673a\u5206\u5f00\u914d\u7684\u539f\u56e0\u3002<\/div>\n  <div class=\"note\"><b>\u4e3a\u4ec0\u4e48\u662f 160 \u5916\u673a\uff0c\u4e0d\u662f 200\uff1f<\/b>\u521d\u7b97\u628a\u6bcf\u95f4\u90fd\u62c9\u6ee1\u3001\u6311\u9ad8\u4e5f\u5355\u72ec\u6298\u7b97\uff0c\u786e\u5b9e\u8981\u4e0a 20kW \u7684 200 \u5916\u673a\u3002\u4f46\u6280\u672f\u603b\u76d1\u542c\u4e86\u60a8\u7684\u5b9e\u9645\u7528\u6cd5\u2014\u2014\u6bcf\u5e74\u4f4f 5\uff5e6 \u4e2a\u6708\u3001\u5e38\u4f4f 3\uff5e5 \u4eba\u3001\u4e0d\u540c\u65f6\u5168\u5c4b\u5f00\u2014\u2014\u628a\u914d\u7f6e\u6536\u6210 160 \u5916\u673a\uff0b6 \u53f0\u5185\u673a\uff08\u8fde\u63a5\u7387 123.1%\uff0c\u5728\u5408\u89c4\u533a\u95f4\u5185\uff09\u3002\u4f4f\u7684\u4eba\u5c11\u3001\u5f00\u7684\u623f\u95f4\u5c11\uff0c\u5c0f\u6392\u5916\u673a<b>\u4e0d\u4f1a\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u9891\u7e41\u542f\u505c<\/b>\uff0c\u53cd\u800c\u7701\u7535\u3002\u8fd9\u4e2a\u5224\u65ad\u8ddf\u8c46\u5305\u7ed9\u60a8\u7684\u5efa\u8bae\u4e00\u81f4\uff0c\u6280\u672f\u603b\u76d1\u548c AI \u8fd9\u56de\u60f3\u5230\u4e86\u4e00\u5904\u3002\u5c0a\u777f\u5168\u6548\u8fd9\u5957\u673a\u5668\u7684\u8be6\u7ec6\u8bb2\u6cd5\u548c\u771f\u5b9e\u7528\u8fc7\u7684\u53cd\u9988\uff0c\u5b98\u7f51\u6709\u4e00\u7bc7\u4e13\u95e8\u62c6\u7684\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=14150\">\u300a\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\u503c\u4e0d\u503c\u5f97\u4e70\uff1f\u4e09\u7ba1\u5236\u6548\u679c\u3001\u4ef7\u683c\u3001\u5bf9\u6bd4\u4e00\u6b21\u8bf4\u6e05\u300b<\/a>\uff08longmai-nt.com\/?page_id=14150\uff09\u3002<\/div>\n  <div class=\"imgbox\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgznjgd.jpg\" alt=\"\u65e5\u7acb\u4e09\u7ba1\u5236\u5185\u673a\u6807\u51c6\u5b89\u88c5\u8d70\u7ba1\u5b9e\u666f\"><b>\u25b2 \u4e09\u7ba1\u5236\u5185\u673a\u8d70\u7ba1\u5b9e\u666f\uff1a\u4e09\u6839\u94dc\u7ba1\uff0b\u51b7\u51dd\u6c34\u7ba1\uff0c\u56de\u6536\u70ed\u91cf\u505a\u9664\u6e7f\u518d\u70ed<\/b><\/div>\n  <div class=\"grid3 gal\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz.jpg\" alt=\"\u4e09\u7ba1\u5236\u5185\u673a\u6807\u51c6\u5b89\u88c5\u5b9e\u666f\u4e00\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz2.jpg\" alt=\"\u4e09\u7ba1\u5236\u5185\u673a\u6807\u51c6\u5b89\u88c5\u5b9e\u666f\u4e8c\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz3.jpg\" alt=\"\u4e09\u7ba1\u5236\u5185\u673a\u6807\u51c6\u5b89\u88c5\u5b9e\u666f\u4e09\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzsnjaz4.jpg\" alt=\"\u4e09\u7ba1\u5236\u5185\u673a\u6807\u51c6\u5b89\u88c5\u5b9e\u666f\u56db\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzgdkcaz.jpg\" alt=\"\u4e09\u7ba1\u5236\u7ba1\u9053\u8de8\u5c42\u5b89\u88c5\u5b9e\u666f\u4e00\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/bltkzc-qls-sgzgdkcaz2.jpg\" alt=\"\u4e09\u7ba1\u5236\u7ba1\u9053\u8de8\u5c42\u5b89\u88c5\u5b9e\u666f\u4e8c\">\n  <\/div>\n  <div class=\"imgbox\" style=\"margin-top:4px\"><b style=\"margin-top:0\">\u25b2 \u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\u5b9e\u666f\uff08\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\uff0c\u591a\u89d2\u5ea6\uff09\uff1a\u673a\u5668\u540a\u88c5\u5b9a\u4f4d\u3001\u8d70\u7ba1\u4fdd\u6e29\u3001\u68c0\u4fee\u53e3\u9884\u7559\uff1b\u540e\u4e24\u5f20\u662f\u7ba1\u9053\u8de8\u5c42\u5b89\u88c5\u2014\u2014\u60a8\u5bb6\u4e09\u5c42\u522b\u5885\u6b63\u597d\u7528\u5f97\u7740<\/b><\/div>\n  <h4>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u673a\uff0c\u5bf9\u60a8\u8eab\u4f53\u6700\u8981\u7d27\u7684\u56db\u4ef6\u4e8b<\/h4>\n  <div class=\"grid2\">\n    <div class=\"card\"><b>\u2460 \u9664\u6e7f\u4e0d\u964d\u6e29<\/b><span>\u4e09\u7ba1\u5236\u628a\u51b7\u51dd\u5e9f\u70ed\u56de\u6536\u7528\u6765\u518d\u70ed\u56de\u98ce\uff0c\u6885\u96e8\u5929\u9664\u6e7f\u65f6\u98ce\u53e3\u5439\u51fa\u6765\u7684\u4e0d\u662f\u51b7\u98ce\u2014\u2014\u6e7f\u6c14\u53bb\u4e86\uff0c\u4eba\u4e0d\u6328\u51bb\u3002\u6e7f\u5ea6 35%\uff5e90% \u4e00\u5ea6\u4e00\u8c03\uff0c56 \u6863\uff0b\u7761\u7720\uff0b\u5168\u5e74\u9664\u6e7f\u6a21\u5f0f\u3002<\/span><\/div>\n    <div class=\"card\"><b>\u2461 \u5173\u7740\u4e3b\u673a\u4e5f\u80fd\u51c0\u5316<\/b><span>\u5185\u673a\u53ef\u5355\u5f00\u5fae\u98ce\u9001\u98ce\u51c0\u5316\u6a21\u5f0f\uff0c\u5355\u53f0\u7ea6 30 \u74e6\uff0c\u4e0d\u5f00\u7a7a\u8c03\u5916\u673a\u5c31\u5f53\u5168\u5c4b\u51c0\u5316\u5668\u4f7f\uff1aPE+ \u51c0\u5316\u6a21\u5757\u5bf9 PM2.5\u3001\u7532\u919b\u3001\u5f02\u5473\u7684\u8fc7\u6ee4\u662f\u8fd9\u5957\u5185\u673a\u7684\u770b\u5bb6\u672c\u9886\u2014\u2014\u5bf9\u9f3b\u708e\u548c\u6162\u963b\u80ba\uff0c\u8fd9\u4e00\u6761\u6700\u5b9e\u5728\u3002<\/span><\/div>\n    <div class=\"card\"><b>\u2462 \u6291\u83cc\u4ece\u6e90\u5934\u505a<\/b><span>\u6da1\u8f6e\u3001\u8717\u58f3\u3001\u63a5\u6c34\u76d8\u5168\u90e8\u6ce8\u5165\u6291\u83cc\u7c92\u5b50\uff1b\u7fc5\u7247\u81ea\u6e05\u6d01\uff0b60\u2103\u9ad8\u6e29\u9664\u83cc\uff1b\u6c34\u6cf5\uff0b\u6d6e\u5b50\u5f00\u5173\u8ba9\u63a5\u6c34\u76d8\u4e0d\u5b58\u6c34\u3001\u4e0d\u53d1\u81ed\u2014\u2014\u4e0d\u53d1\u9709\u7684\u673a\u5668\u624d\u6709\u5e72\u51c0\u7684\u98ce\u3002<\/span><\/div>\n    <div class=\"card\"><b>\u2463 \u8584\u3001\u9759<\/b><span>\u673a\u8eab 192mm \u8d85\u8584\u3001\u8fdb\u6df1 447mm\uff0c\u540a\u9876\u538b\u5230 25 \u516c\u5206\u4e0d\u538b\u6291\uff1b\u8fd0\u884c 17dB\uff0c\u56fe\u4e66\u9986\u7ea7\u2014\u2014\u5367\u5ba4\u6574\u591c\u5f00\u4e5f\u5435\u4e0d\u7740\u89c9\u3002<\/span><\/div>\n  <\/div>\n\n  <!-- \u56db\u3001\u5730\u6696 -->\n  <span class=\"step-tag\">\u56db \u00b7 \u5730\u6696\uff1a132\u33a1\uff0c\u4e3b\u673a\u76f4\u63a5\u5e26\uff0c\u4e0d\u7528\u518d\u4e70\u58c1\u6302\u7089<\/span>\n  <h3>\u6c34\u6a21\u5757\u53d6\u70ed\uff0c\u4f1f\u661f\u76d8\u7ba1\uff0c\u5382\u5bb6\u7b2c\u4e09\u65b9\u76d1\u7406<\/h3>\n  <p>\u5929\u6c1f\u5730\u6c34\u7684\u597d\u5904\u5728\u8fd9\u91cc\uff1a\u5730\u6696\u7684\u70ed\u91cf\u4ece\u7a7a\u8c03\u4e3b\u673a\u7684\u6c34\u6a21\u5757\u53d6\uff0c<b>\u7701\u6389\u4e00\u53f0\u58c1\u6302\u7089\u7684\u94b1\u548c\u5b83\u7684\u540e\u671f\u7ef4\u4fdd<\/b>\u3002\u6c34\u6a21\u5757 RWMG-160FWXNZQ\uff08\u9762\u4ef7 8,375 \u5143\uff0b\u5b89\u88c5 625 \u5143\uff0b\u6c34\u6a21\u5757\u63a7\u5236\u5668 300 \u5143\uff0c\u5408\u8ba1 9,300 \u5143\uff09\u8d1f\u8d23\u6c1f\u4e0e\u6c34\u7684\u6362\u70ed\uff0c\u51ac\u5929\u6574\u5c4b\u5730\u9762\u4f9b\u6696 132\u33a1\uff0c\u603b\u5236\u70ed\u9700\u6c42\u7ea6 13,800W\uff08\u7ea6 104W\/\u33a1\uff0c\u542b\u4e8c\u5c42\u516c\u533a\u6311\u9ad8 6 \u7c73\u6309\u4f53\u79ef\u6298\u7b97\u589e\u52a0\u7684\u7ea6 2,000W\uff09\u2014\u2014\u4e3b\u673a 18kW \u5236\u70ed\uff0c\u7559\u6709\u4f59\u91cf\u3002<\/p>\n  <table>\n    <thead><tr><th>\u697c\u5c42<\/th><th>\u533a\u57df<\/th><th>\u9762\u79ef\u33a1<\/th><th>\u76d8\u7ba1\u56de\u8def<\/th><th>\u95f4\u8ddd<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e00\u5c42<\/td><td>\u5ba2\u9910\u5385\uff0b\u5f00\u653e\u5f0f\u53a8\u623f<\/td><td>64<\/td><td>4 \u8def<\/td><td>200mm<\/td><\/tr>\n      <tr><td>\u4e8c\u5c42<\/td><td>\u5367\u5ba41 \uff0f \u516c\u533a<\/td><td>13.9 \uff0f 20<\/td><td>\u5404 1 \u8def<\/td><td>200mm<\/td><\/tr>\n      <tr><td>\u4e09\u5c42<\/td><td>\u5367\u5ba41 \uff0f \u5367\u5ba42\uff0b\u8fc7\u9053<\/td><td>19.6 \uff0f 15<\/td><td>\u5404 1 \u8def<\/td><td>200mm<\/td><\/tr>\n      <tr><td colspan=\"2\"><b>\u5408\u8ba1<\/b><\/td><td><b>132<\/b><\/td><td>8 \u8def \u00b7 3 \u4e2a\u5206\u6c34\u7bb1<\/td><td>\u76d8\u7ba1 dn20\u00d7en2.0 \u5171 568m<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"imgbox\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/snys-zls-dnpg-01.jpg\" alt=\"\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\u5730\u6696\u76d8\u7ba1\u5b9e\u62cd\"><b>\u25b2 \u5730\u6696\u76d8\u7ba1\u5b9e\u62cd\uff08\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\uff09\u3002dn20 \u7ba1\u6bd4\u5e38\u7528 dn16 \u6d41\u91cf\u5927\u3001\u4f9b\u70ed\u80fd\u529b\u66f4\u5f3a\uff0c\u95f4\u8ddd 200mm \u94fa\u8bbe<\/b><\/div>\n  <div class=\"grid2\">\n    <div class=\"card\"><b>\u4f1f\u661f\u5168\u94dc\u5206\u96c6\u6c34\u5668<\/b><span>\u5168\u94dc\u953b\u9020\u4e3b\u6760\u9540\u954d\uff0c\u9694\u7edd\u7a7a\u6c14\u4e0e\u6c34\u3001\u4e0d\u6c27\u5316\u751f\u9508\uff1b8 \u8def\u72ec\u7acb\u63a7\u5236\uff0c\u6ca1\u4eba\u7684\u623f\u95f4\u5173\u6389\u5c31\u7701\u6c14\u7701\u7535\u3002<\/span><\/div>\n    <div class=\"card\"><b>\u4e09\u5c42\u4fdd\u9669<\/b><span>\u2460\u4f1f\u661f\u661f\u76d1\u7406\uff1a\u5382\u5bb6\u7b2c\u4e09\u65b9\u76d1\u7406\uff0c\u68c0\u67e5\u3001\u6253\u538b\u3001VR \u5168\u666f\u8bb0\u5f55\uff1b\u2461\u7ba1\u8def\u56fe 360\u00b0 \u5168\u666f\u5f55\u5165\u5b98\u7f51\uff0c\u968f\u65f6\u53ef\u67e5\uff1b\u2462\u9f99\u8109\uff0b\u4f1f\u661f\uff0b\u4e2d\u56fd\u4eba\u4fdd 50 \u5e74\u4ea7\u54c1\u8054\u4fdd\u3002<\/span><\/div>\n  <\/div>\n  <div class=\"imgbox\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/lqhdlz-lls-jfsqaz-qm-03.jpg\" alt=\"\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5168\u8c8c\u5b9e\u666f\"><b>\u25b2 \u5206\u96c6\u6c34\u5668\u5b89\u88c5\u5168\u8c8c\u5b9e\u62cd\u3002\u7ba1\u8def\u7cfb\u7edf\u542b\u538b\u5dee\u65c1\u901a\u9600\u3001Y \u578b\u8fc7\u6ee4\u5668\u3001\u81ea\u52a8\u6392\u6c14\u9600\u3001\u5b89\u5168\u9600\uff0c\u6c34\u7cfb\u7edf\u8be5\u6709\u7684\u4fdd\u62a4\u4e00\u6837\u4e0d\u7f3a\uff1b\u5730\u6696\u6c34\u6e29\u7531\u65e5\u7acb\u7ebf\u63a7\u5668\u8054\u52a8\u63a7\u5236\uff08\u5382\u5bb6\u539f\u5e26\uff09\uff0c\u4e0d\u9700\u8981\u989d\u5916\u88c5\u4e2d\u592e\u8054\u52a8\u63a7\u5236<\/b><\/div>\n  <p style=\"font-size:13px\">\u60f3\u5f04\u660e\u767d\"\u5929\u6c1f\u5730\u6c34\"\u5230\u5e95\u662f\u600e\u4e48\u56de\u4e8b\u3001\u8ddf\u522b\u7684\u505a\u6cd5\u600e\u4e48\u6bd4\uff0c\u5b98\u7f51\u8fd9\u4e24\u7bc7\u5199\u5f97\u7ec6\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=13115\">\u300a\u4ec0\u4e48\u662f\u4e8c\u8054\u4f9b\uff1f\u4e00\u5957\u7cfb\u7edf\uff0c\u590f\u5929\u5236\u51b7\u3001\u51ac\u5929\u5730\u6696\u300b<\/a>\uff08longmai-nt.com\/?page_id=13115\uff09\u3001<a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u300a\u6210\u90fd\u6c34\u673avs\u6c1f\u673a\uff5c\u5929\u6c34\u5730\u6c34\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u600e\u4e48\u9009\u300b<\/a>\uff08longmai-nt.com\/?page_id=12825\uff09\u3002<\/p>\n\n  <!-- \u4e94\u3001\u65b0\u98ce -->\n  <span class=\"step-tag\">\u4e94 \u00b7 \u65b0\u98ce\uff1a\u4e24\u5c42\u623f\uff0c\u4e24\u53f0\u4e3b\u673a\u5206\u5c42\u9001<\/span>\n  <h3>\u6309\u56fd\u6807\u7b97\u98ce\u91cf\uff0c\u4e0d\u662f\u6309\u673a\u5668\u51d1\u9762\u79ef<\/h3>\n  <p>\u4f9d\u636e\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300bJGJ\/T 440-2018 \u9010\u95f4\u7b97\uff1a\u65b0\u98ce\u8986\u76d6\u9762\u79ef\u7ea6 128\u33a1\uff08\u4e00\uff0b\u4e8c\u5c42 98\u3001\u4e09\u5c42 30\uff09\uff0c\u5168\u5c4b\u65b0\u98ce\u9700\u6c42\u7ea6 220 m\u00b3\/h\uff08\u4e00\uff0b\u4e8c\u5c42 170\u3001\u4e09\u5c42 50\uff09\uff0c\u518d\u6309\u5f97\u98ce\u7387 0.8\u3001\u5b89\u5168\u7cfb\u6570 1.1 \u7559\u8db3\u4f59\u91cf\uff0c\u914d<b>\u4e24\u53f0\u5929\u51c0\u4e3b\u673a\u5206\u5c42\u5b89\u88c5<\/b>\uff1a<\/p>\n  <table>\n    <thead><tr><th>\u8986\u76d6<\/th><th>\u673a\u578b<\/th><th>\u98ce\u91cf<\/th><th>\u9001\/\u6392\u98ce\u53e3<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e00\uff0b\u4e8c\u5c42\uff08\u5ba2\u9910\u5385\u3001\u5367\u5ba4\u3001\u516c\u533a\uff09<\/td><td>KPI-3521Q5\/F<\/td><td>350 m\u00b3\/h<\/td><td>5 \u9001 \/ 5 \u6392<\/td><\/tr>\n      <tr><td>\u4e09\u5c42\uff08\u4e24\u95f4\u5367\u5ba4\uff09<\/td><td>KPI-1521Q5\/F<\/td><td>150 m\u00b3\/h<\/td><td>2 \u9001 \/ 2 \u6392<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p>\u771f\u5982 PE \u73af\u4fdd\u6ce2\u7eb9\u7ba1\u8d70\u7ba1\uff0c304 \u4e0d\u9508\u94a2\u9632\u96e8\u5916\u98ce\u7f69\uff0c\u98ce\u53e3 ABS \u65cb\u8f6c\u53ef\u8c03\u3002\u4e24\u53f0\u5404\u914d\u5929\u51c0\u7ebf\u63a7\u5668 PC-P1HPQ2\uff0c\u5b9e\u65f6\u663e\u793a PM2.5\u3001CO2\u3001VOC\u3001\u6e29\u6e7f\u5ea6\uff0c\u5e76\u63a5\u5165\u96c6\u63a7\u5c4f\u3002<\/p>\n\n  <!-- \u516d\u3001\u96c6\u63a7\u5c4f -->\n  <span class=\"step-tag\">\u516d \u00b7 \u667a\u6167\u96c6\u63a7\u5c4f\uff1a\u5168\u5c4b\u7684\u4e00\u5757\u603b\u5c4f<\/span>\n  <h3>\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u95e8\u7a97\u3001\u706f\u5149\uff0c\u4e00\u5757\u5c4f\u7ba1\u5b8c<\/h3>\n  <div class=\"imgbox tall\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/68a3dccaf2c1cb79a8c19d62b89fb0e7.jpg\" alt=\"\u65e5\u7acb\u667a\u6167\u96c6\u63a7\u5c4f\u5b9e\u7269\"><b>\u25b2 \u65e5\u7acb\u667a\u6167\u96c6\u63a7\u5c4f\uff08\u672c\u65b9\u6848\u914d CCS-160R1D\uff09<\/b><\/div>\n  <div class=\"imgbox tall\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/RILIZHJKPJGT.png\" alt=\"\u65e5\u7acbAI\u667a\u6167\u5c4fCCS-64W1D\u7ed3\u6784\u56fe\"><b>\u25b2 \u667a\u80fd\u7f51\u5173\u7ed3\u6784\u4e0e\u63a5\u53e3\u56fe\uff08\u5bbd115\u00d7\u9ad8127\u00d7\u539a60.5mm\uff0c\u5bfc\u8f68\u5f0f\u5b89\u88c5\uff09\uff1a24V \u4f9b\u7535\u3001H-Link \u7a7a\u8c03\u901a\u4fe1\u3001RS485 \u63a5\u4e2d\u63a7\u5c4f\u4e0e\u7a97\u5e18\u7535\u673a\u3001\u706f\u5149 1\uff5e4\u3001\u8f93\u5165\/\u8f93\u51fa\u5e72\u63a5\u70b9\u5404 4 \u8def\u3001\u5730\u6696\u9600\u63a5\u53e3\u9884\u7559<\/b><\/div>\n  <table>\n    <tr><td class=\"k\">\u63a7\u5236\u8303\u56f4<\/td><td>\u7a7a\u8c03\u6700\u591a 16 \u4e2a\u7cfb\u7edf\u300164 \u53f0\u5185\u673a\u9010\u53f0\u63a7\u5236\uff1b\u5730\u6696\u6c34\u6a21\u5757\u3001\u5929\u51c0\u65b0\u98ce\u3001\u7a7a\u6c14\u76d2\u5b50\uff08PM2.5\/CO2\/\u6e29\u6e7f\u5ea6\uff09\uff1b\u706f\u5149\u6700\u591a 4 \u8def\uff08\u6bcf\u8def\u4e0d\u8d85\u8fc7 200W\uff09\uff1b\u7a97\u5e18\u7535\u673a\u7b49 485 \u8bbe\u5907\u8d70\u72ec\u7acb\u603b\u7ebf\uff1b\u8fd8\u53ef\u66ff\u4ee3 4 \u4e2a\u7ebf\u63a7\u5668\uff0c\u8f93\u5165\/\u8f93\u51fa\u5e72\u63a5\u70b9\u5404 4 \u8def\uff08\u63a5\u4f20\u611f\u5668\u3001\u62a5\u8b66\u5668\uff09<\/td><\/tr>\n    <tr><td class=\"k\">\u573a\u666f<\/td><td>\u6700\u591a 16 \u4e2a\u573a\u666f\uff0c\u63a8\u8350\u573a\u666f\uff0b\u81ea\u5b9a\u4e49\uff1b\u6e7f\u5ea6\u8d85\u9608\u503c\u81ea\u52a8\u9664\u6e7f\u5e76\u8054\u52a8\u65b0\u98ce\u6863\u4f4d\uff1b\u51ac\u590f\u6a21\u5f0f\u65b0\u98ce\u81ea\u52a8\u6362\u6863\uff1b\u5b9a\u65f6\u3001\u7a7a\u7f6e\u4fdd\u6e29\u6a21\u5f0f\uff08\u957f\u671f\u4e0d\u5728\u5bb6\u65f6\u4f4e\u6e29\u4fdd\u6e29\u3001\u4fdd\u62a4\u5730\u6696\u7ba1\u8def\uff09<\/td><\/tr>\n    <tr><td class=\"k\">\u8fdc\u7a0b<\/td><td>\u65e5\u7acb\u667a\u5bb6 APP\uff1a\u5404\u623f\u95f4\u6e29\u6e7f\u5ea6\u3001\u8bbe\u5907\u8fd0\u884c\u3001\u7a97\u6237\u5f00\u95ed\u72b6\u6001\u968f\u624b\u770b<\/td><\/tr>\n    <tr><td class=\"k\">\u65ad\u7535\u515c\u5e95<\/td><td>\u7f51\u5173\u72ec\u7acb\u4f9b\u7535\uff1a\u8fc7\u6e21\u5b63\u7a7a\u8c03\u65ad\u7535\u65f6\uff0c\u706f\u5149\u3001\u7a97\u5e18\u7167\u5e38\u53ef\u63a7\uff1b\u4e0b\u96e8\u81ea\u52a8\u5173\u7a97\u662f\u7687\u6d3e\u672c\u5730\u529f\u80fd\uff0c\u4e0d\u4f9d\u8d56\u96c6\u63a7\u5c4f\u3001\u4e0d\u4f9d\u8d56\u5916\u7f51\u2014\u2014\u8fd9\u6761\u5199\u8fdb\u9a8c\u6536\u6e05\u5355<\/td><\/tr>\n    <tr><td class=\"k\">\u8bed\u97f3<\/td><td>AI \u8bed\u97f3\u652f\u6301\u56db\u5ddd\u8bdd\u7b49 7 \u79cd\u65b9\u8a00<b>\u79bb\u7ebf\u8bc6\u522b<\/b>\u2014\u2014\u65ad\u7f51\u4e5f\u80fd\u558a\u5f97\u52a8<\/td><\/tr>\n    <tr><td class=\"k\">\u7ef4\u62a4<\/td><td>OTA \u5728\u7ebf\u5347\u7ea7\uff1b\u66ff\u4ee3 4 \u4e2a\u7ebf\u63a7\u5668 \uff0b 4 \u8def\u706f\u5f00\u5173\uff0c\u5899\u9762\u4e0a\u5c11\u4e00\u5927\u6392\u9762\u677f<\/td><\/tr>\n  <\/table>\n  <div class=\"imgbox tall\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/RLZHJKPJXYLT.png\" alt=\"\u65e5\u7acbAI\u667a\u6167\u5c4fCCS-64W1D\u63a5\u7ebf\u539f\u7406\u56fe\"><b>\u25b2 \u65e5\u7acb AI \u667a\u6167\u5c4f CCS-64W1D \u63a5\u7ebf\u539f\u7406\u56fe\uff1a\u7a7a\u8c03\u3001\u65b0\u98ce\u3001\u6c34\u6a21\u5757\u3001\u706f\u5149\u7a97\u5e18\u3001\u96c6\u63a7\u5c4f\uff08\u7f51\u5173\uff09\u4e00\u6761\u603b\u7ebf\u4e32\u8d77\u6765<\/b><\/div>\n  <p style=\"font-size:13px\">\u96c6\u63a7\u5c4f\u80fd\u505a\u4ec0\u4e48\u3001\u63a5\u53e3\u53c2\u6570\u6709\u54ea\u4e9b\uff0c\u6211\u4eec\u5b98\u7f51\u4e0a\u6302\u4e86\u4e00\u672c\u5b8c\u6574\u7684\u8d44\u6599\u624b\u518c\uff0c\u968f\u65f6\u53ef\u7ffb\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=847\">\u300a\u65e5\u7acb\u667a\u6167\u96c6\u63a7\u5c4f\/AI\u667a\u63a7\u5c4f \u6280\u672f\u8d44\u6599\u624b\u518c\u300b<\/a>\uff08longmai-nt.com\/?page_id=847\uff09\u3002<\/p>\n  <div class=\"note\"><b>\u5173\u4e8e\u7b2c\u4e09\u65b9\u7535\u52a8\u7a97\u5e18\uff1a<\/b>\u96c6\u63a7\u5c4f\u7cfb\u7edf\u81ea\u5e26 RS485 \u901a\u8baf\u548c\u7a97\u5e18\u7535\u673a 485 \u63a5\u53e3\uff0c\u652f\u6301\u7b2c\u4e09\u65b9\u8bbe\u5907\u63a5\u5165\uff08\u706f\u5149\u7a97\u5e18\u6700\u591a 4 \u8def\uff09\u3002\u60a8\u90a3\u5957\u7535\u52a8\u7a97\u5e18\u80fd\u5426\u76f4\u63a5\u63a5\u5165\u3001\u8fd8\u662f\u8981\u7ecf\u8fc7\u534f\u8bae\u8f6c\u6362\uff0c<b>\u52d8\u6d4b\u65f6\u770b\u7a97\u5e18\u7535\u673a\u5e26\u7684\u534f\u8bae\u5b9a<\/b>\uff0c\u63a5\u5165\u65b9\u6848\u548c\u8c03\u8bd5\u8d39\u5728\u62a5\u4ef7\u91cc\u9010\u9879\u5217\u660e\uff0c\u4e0d\u7559\u6a21\u7cca\u9879\u3002<\/div>\n\n  <!-- \u4e03\u3001\u7687\u6d3e\u95e8\u7a97 -->\n  <span class=\"step-tag\">\u4e03 \u00b7 \u7687\u6d3e\u7535\u52a8\u95e8\u7a97\u8054\u52a8\uff1a\u5148\u628a\u4e11\u8bdd\u8bf4\u6e05\u695a\uff0c\u518d\u628a\u597d\u4e8b\u505a\u624e\u5b9e<\/span>\n  <h3>\u54ea\u4e9b\u662f\u7687\u6d3e\u81ea\u5df1\u7684\u672c\u4e8b\uff0c\u54ea\u4e9b\u9760\u5bf9\u63a5\uff0c\u5206\u6e05\u695a<\/h3>\n  <div class=\"grid2\">\n    <div class=\"okbox\"><b>\u7687\u6d3e\u539f\u751f\u7684\uff0c\u4e00\u6839\u7ebf\u90fd\u4e0d\u52a8<\/b><br>\u96e8\u5929\u81ea\u52a8\u5173\u7a97\u662f\u5f00\u7a97\u5668<b>\u672c\u5730\u81ea\u5e26<\/b>\u7684\u529f\u80fd\uff0c\u72ec\u7acb\u8fd0\u884c\u2014\u2014\u4e0d\u4f9d\u8d56\u65e5\u7acb\u96c6\u63a7\u5c4f\u3001\u4e0d\u4f9d\u8d56\u7f51\u5173\u3001\u4e0d\u4f9d\u8d56\u5916\u7f51\u3002\u7f51\u5173\u65ad\u7535\u3001\u7cfb\u7edf\u6545\u969c\u3001\u65ad\u7f51\uff0c\u4e0b\u96e8\u5173\u7a97\u7167\u6837\u6267\u884c\u3002\u8fd9\u6761\u5199\u8fdb\u9a8c\u6536\u6807\u51c6\uff0c\u73b0\u573a\u65ad\u7f51\u6f14\u793a\u3002<\/div>\n    <div class=\"card\"><b>\u9760\u5bf9\u63a5\u5b9e\u73b0\u7684<\/b><br>\u2460\u5f00\u7a7a\u8c03\/\u5730\u6696\/\u65b0\u98ce\u65f6\u81ea\u52a8\u5173\u5bf9\u5e94\u533a\u57df\u7a97\u6237\uff1b\u2461\u4e00\u952e\u79bb\u5bb6\uff1a\u5173\u7a7a\u8c03\u3001\u5173\u5730\u6696\u3001\u5173\u65b0\u98ce\u3001\u5173\u7a97\u3001\u5173\u706f\u3001\u5e03\u9632\u4e00\u8d77\u6267\u884c\uff1b\u2462\u4e00\u952e\u56de\u5bb6\uff1a\u5f00\u95e8\u89e6\u53d1\u7384\u5173\u706f\u3001\u6309\u9884\u8bbe\u542f\u52a8\u65b0\u98ce\uff1b\u2463\u96c6\u63a7\u5c4f\u548c APP \u4e0a\u9010\u6247\u5f00\u5173\u3001\u9010\u6247\u770b\u72b6\u6001\u3002\u8fc7\u8f7d\u4fdd\u62a4\u3001\u9047\u963b\u505c\u7b49\u7687\u6d3e\u539f\u751f\u4fdd\u62a4\u5168\u90e8\u4fdd\u7559\u3002<\/div>\n  <\/div>\n  <p>\u5bf9\u63a5\u65b9\u5f0f\uff1a\u7687\u6d3e\u5f00\u7a97\u5668 485 \u603b\u7ebf \u2192 \u65e5\u7acb\u7cfb\u7edf 485 \u63a5\u53e3\uff08\u662f\u5426\u9700\u8981\u534f\u8bae\u8f6c\u6362\u6a21\u5757\uff0c\u52d8\u6d4b\u540e\u6309\u73b0\u573a\u8bbe\u5907\u5b9a\uff09\u3002<b>\u5e03\u7ebf\u6807\u51c6\u7167\u884c\u89c4\u8d70<\/b>\uff1aRVSP 2\u00d70.75 \u53cc\u7ede\u5c4f\u853d\u7ebf\u3001\u624b\u62c9\u624b\u4e32\u8054\u3001\u4e0d\u4e0e\u5f3a\u7535\u540c\u7ba1\u3001\u5e73\u884c\u95f4\u8ddd\u226530cm\u3001\u5c4f\u853d\u5c42\u5355\u7aef\u63a5\u5730\u3001\u7ba1\u7ebf\u7f16\u53f7\uff0c\u5b8c\u5de5\u4ea4\u7ebf\u8def\u56fe\u548c\u901a\u65ad\u6d4b\u8bd5\u8bb0\u5f55\u3002<\/p>\n  <div class=\"warn\"><b>\u552e\u540e\u8d23\u4efb\uff0c\u4e00\u53e5\u8bdd\u8bf4\u6b7b\uff1a<\/b>\u6696\u901a\u8bbe\u5907\u3001\u5f00\u7a97\u8054\u52a8\u3001\u667a\u80fd\u573a\u666f\uff0c<b>\u7edf\u4e00\u7531\u9f99\u8109\u5bf9\u63a5\u8d1f\u8d23\u5230\u5e95<\/b>\uff0c\u4e0d\u4f1a\u51fa\u73b0\"\u6696\u901a\u63a8\u95e8\u7a97\u3001\u95e8\u7a97\u63a8\u667a\u80fd\"\u4e92\u76f8\u8e22\u76ae\u7403\u3002\u8fd9\u6761\u5199\u8fdb\u5408\u540c\u3002<\/div>\n\n  <!-- \u516b\u3001\u667a\u80fd\u70b9\u4f4d -->\n  <span class=\"step-tag\">\u516b \u00b7 \u706f\u5149\u3001\u5b89\u9632\u3001\u8dcc\u5012\u68c0\u6d4b\uff1a\u6309\u70b9\u4f4d\u62a5\u4ef7\uff0c\u4e0d\u7559\u7cca\u6d82\u8d26<\/span>\n  <h3>\u9002\u8001\u5316\u667a\u80fd\u70b9\u4f4d\u8fd9\u5757\uff0c\u6211\u4eec\u6309\"\u9a8c\u6536\u6e05\u5355\"\u6765\u505a<\/h3>\n  <p>\u60a8\u63d0\u7684\u6beb\u7c73\u6ce2\u4eba\u4f53\u5b58\u5728\u3001\u536b\u751f\u95f4\/\u5367\u5ba4\u8dcc\u5012\u68c0\u6d4b\u3001\u8d77\u591c\u67d4\u5149\u3001\u95e8\u7a97\u78c1\u3001\u7384\u5173\u4e00\u952e\u9762\u677f\u2014\u2014\u8fd9\u4e9b\u90fd\u662f\u771f\u9700\u6c42\uff0c\u4f46<b>\u6bcf\u4e2a\u724c\u5b50\u3001\u6bcf\u4e2a\u70b9\u4f4d\u7684\u534f\u8bae\u548c\u4ef7\u4e0d\u4e00\u6837<\/b>\uff0c\u6211\u4eec\u4e0d\u6253\u5305\u7cca\u5f04\u3002\u505a\u6cd5\u662f\uff1a<\/p>\n  <ul>\n    <li>\u52d8\u6d4b\u65f6\u9010\u70b9\u4f4d\u6e05\u70b9\uff1a\u51e0\u8def\u706f\u3001\u51e0\u4e2a\u4f20\u611f\u5668\u3001\u51e0\u4e2a\u9762\u677f\u3001\u88c5\u5728\u54ea\uff1b<\/li>\n    <li>\u6bcf\u4e2a\u70b9\u4f4d\u5217\u54c1\u724c\u3001\u578b\u53f7\u3001\u6570\u91cf\u3001\u5b89\u88c5\u8c03\u8bd5\u8d39\uff0c<b>\u6309\u6e05\u5355\u62a5\u4ef7<\/b>\uff1b<\/li>\n    <li>\u54ea\u4e9b\u529f\u80fd\u65ad\u7f51\u53ef\u7528\u3001\u54ea\u4e9b\u9700\u8981\u7f51\u7edc\uff0c\u9010\u9879\u6807\u6ce8\u3001\u9010\u9879\u73b0\u573a\u6f14\u793a\u540e\u7b7e\u5b57\u9a8c\u6536\uff1b<\/li>\n    <li>\u8dcc\u5012\u544a\u8b66\u8981\u6c42\u505a\u5230\uff1a\u672c\u5730\u89e6\u53d1\u58f0\u5149\u63d0\u9192\uff0bAPP \u63a8\u9001\uff0c\u5177\u4f53\u5b9e\u73b0\u65b9\u5f0f\u52d8\u6d4b\u786e\u8ba4\u540e\u5199\u8fdb\u5408\u540c\u9644\u4ef6\u3002<\/li>\n    <li>\u7f51\u5173\u5e26\u8f7d\u5bb9\u91cf\uff08\u5382\u5bb6\u63a5\u7ebf\u56fe\u6807\u6ce8\uff09\uff1a\u706f\u5149\u6700\u591a 4 \u8def\u3001485 \u8bbe\u5907\u72ec\u7acb\u603b\u7ebf\u3001\u53ef\u66ff\u4ee3 4 \u4e2a\u7ebf\u63a7\u5668\u3001\u5e72\u63a5\u70b9\u8f93\u5165\/\u8f93\u51fa\u5404 4 \u8def\u2014\u2014\u60a8\u7684\u70b9\u4f4d\u6e05\u5355\u6309\u8fd9\u4e2a\u5bb9\u91cf\u505a\u8bbe\u8ba1\uff0c\u8d85\u51fa\u7684\u52a0\u6269\u5c55\u6a21\u5757\uff0c\u9010\u9879\u5217\u4ef7\u3002<\/li>\n  <\/ul>\n\n  <!-- \u4e5d\u3001\u67d0\u5730\u623f -->\n  <span class=\"step-tag\">\u4e5d \u00b7 \u8d35\u5dde\u67d0\u5730\u907f\u6691\u623f\uff1a\u53e6\u4e00\u5957\u601d\u8def\uff0c\u53e6\u51fa\u65b9\u6848<\/span>\n  <h3>\u4e0d\u52a8\u7a7a\u8c03\uff0c\u53ea\u89e3\u51b3\"\u5c4b\u91cc\u7a7a\u6c14\u5e72\u51c0\"<\/h3>\n  <p>\u67d0\u5730\u623f\u590f\u5929\u4e8c\u5341\u591a\u5ea6\u4e0d\u7528\u7a7a\u8c03\uff0c\u9ebb\u70e6\u5728\u5ba4\u5916\u2014\u2014\u70df\u5382\u9152\u5382\u7684\u6c14\u5473\u3002\u6240\u4ee5\u90a3\u8fb9<b>\u4e0d\u505a\u70ed\u56de\u6536\u53cc\u5411\u65b0\u98ce<\/b>\uff08\u70ed\u56de\u6536\u4f1a\u628a\u5ba4\u5916\u6c14\u5473\u5e26\u8fdb\u6765\uff09\uff0c\u6539\u7528<b>\u5355\u5411\u6d41\u51c0\u5316\u65b0\u98ce<\/b>\uff1a\u673a\u5668\u8fc7\u6ee4\u540e\u628a\u5e72\u51c0\u7a7a\u6c14\u9001\u8fdb\u5404\u623f\u95f4\uff0c\u5ba4\u5185\u810f\u7a7a\u6c14\u4ece\u5bf9\u89d2\/\u536b\u751f\u95f4\u6392\u8d70\uff0c\u5f62\u6210\"\u9001\u8fdb\u6765\u7684\u662f\u51c0\u7684\u3001\u6324\u51fa\u53bb\u7684\u662f\u810f\u7684\"\u3002<\/p>\n  <ul>\n    <li><b>\u5c42\u9ad8 2.65 \u7c73\u3001\u6881\u9ad8 350 \u7684\u8fc7\u6881\u95ee\u9898<\/b>\uff1a\u4f18\u5148 110 \u5b54\u8fc7\u6881\uff0c\u7528\u53d8\u5f84\uff08110 \u53d8 70\/75\uff09\"\u88e4\u8869\u5f0f\"\u5206\u6d41\uff0c\u5f00\u5b54\u524d\u94a2\u7b4b\u63a2\u6d4b\u4eea\u626b\u7b4b\u3001\u8de8\u4e2d\u5f00\u5b54\u3001\u907f\u5f00\u4e3b\u7b4b\u2014\u2014\u6309\u7ed3\u6784\u89c4\u8303\u6765\uff0c\u98ce\u91cf\u635f\u5931\u5f88\u5c0f\uff1b<\/li>\n    <li><b>\u6ca1\u540a\u9876<\/b>\uff1a\u7ba1\u8def\u8d70\u77ed\u3001\u8d70\u76f4\uff0c\u5927\u5f27\u5f2f\u964d\u98ce\u566a\uff0c\u98ce\u53e3 2.4\uff5e2.5 \u7c73\uff1b<\/li>\n    <li><b>\u8fdc\u9001\u8fd1\u56de<\/b>\uff1a\u95e8\u5e38\u5f00\u96c6\u4e2d\u56de\u98ce\uff0c\u95e8\u5173\u7684\u623f\u95f4\u9760\u95e8\u7f1d\/\u672b\u7aef\u98ce\u673a\u8f85\u52a9\uff0c\u4e0d\u77ed\u8def\u4e0d\u7559\u6b7b\u89d2\u3002<\/li>\n  <\/ul>\n  <p>\u67d0\u5730\u623f\u7684\u5177\u4f53\u914d\u7f6e\u548c\u62a5\u4ef7\uff0c\u7b49\u60a8\u628a\u6237\u578b\u56fe\u53d1\u6765\u540e<b>\u5355\u72ec\u51fa\u4e00\u4efd<\/b>\uff0c\u8ddf\u522b\u5885\u8fd9\u4efd\u5206\u5f00\u7b97\u8d26\u3002<\/p>\n\n  <!-- \u5341\u3001\u7535\u8d39 -->\n  <span class=\"step-tag\">\u5341 \u00b7 \u7535\u8d39\uff1a\u60a8\u9760\u957f\u671f\u751f\u6d3b\u751f\u6d3b\uff0c\u8fd9\u7b14\u8d26\u8981\u7b97\u660e\u767d<\/span>\n  <h3>\u771f\u5b9e\u5ba2\u6237\u7684\u7535\u8d39\u5355<\/h3>\n  <div class=\"okbox\">\u57ce\u5357\u67d0\u5c0f\u533a\u4e00\u4f4d\u65e5\u7acb\u5ba2\u6237\uff0c\u590f\u5b63\u4e09\u53f0\u5185\u673a\u5e38\u5f00\uff0c<b>\u4e00\u4e2a\u6708\u7535\u8d39\u7ea6 400 \u5143\uff08\u542b\u5bb6\u91cc\u5168\u90e8\u751f\u6d3b\u7528\u7535\uff09<\/b>\uff0c\u6700\u9ad8\u4e00\u5929\u5341\u591a\u5ea6\u7535\u3002\u60a8\u8fd9\u5957\u5916\u673a\u6bd4\u4ed6\u5c0f\u4e00\u6863\u3001\u6bcf\u5e74\u53ea\u4f4f 5\uff5e6 \u4e2a\u6708\uff0c\u6b63\u5e38\u4f7f\u7528\u4e0d\u4f1a\u66f4\u9ad8\u3002<\/div>\n  <p>\u7701\u7535\u7684\u9053\u7406\u6709\u4e24\u4e2a\uff1a\u4e00\u662f 160 \u5916\u673a\u4e0d\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\uff0c\u542f\u505c\u5c11\uff1b\u4e8c\u662f\u60a8\u957f\u671f\u4e0d\u5728\u5bb6\u65f6\uff0c\u96c6\u63a7\u5c4f\u7684<b>\u7a7a\u7f6e\u4fdd\u6e29\u6a21\u5f0f<\/b>\u8ba9\u5730\u6696\u4fdd\u6301\u4f4e\u6e29\u8fd0\u884c\u4fdd\u62a4\u7ba1\u8def\uff0c\u800c\u4e0d\u662f\u5168\u5173\u518d\u5168\u5f00\u2014\u2014\u56de\u6765\u524d\u624b\u673a\u4e0a\u63d0\u524d\u6253\u5f00\uff0c\u8fdb\u95e8\u5c31\u662f\u6696\u7684\u3002<\/p>\n\n  <!-- \u5341\u4e00\u3001\u4ef7\u683c -->\n  <span class=\"step-tag\">\u5341\u4e00 \u00b7 \u4ef7\u683c\uff1a\u6bcf\u4e00\u5206\u6446\u5728\u660e\u9762\u4e0a<\/span>\n  <h3>\u62a5\u4ef7\u6c47\u603b<\/h3>\n  <table class=\"price-table\">\n    <thead><tr><th>\u9879\u76ee<\/th><th>\u91d1\u989d\uff08\u5143\uff09<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td>\u4e00\u3001\u4e2d\u592e\u7a7a\u8c03\uff08\u542b\u667a\u6167\u96c6\u63a7\u5c4f\u4e0e 6 \u4e2a\u9ad8\u6e05\u7ebf\u63a7\u5668\uff09<\/td><td><b>\uff08\u8bbe\u5907\u6309\u5382\u5bb6\u516c\u5f00\u4ef7\u9010\u9879\u5217\u660e\uff0c\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/b><\/td><\/tr>\n      <tr><td>\u4e8c\u3001\u5730\u6696\u7cfb\u7edf\uff08\u542b\u6c34\u6a21\u5757\u3001\u76d8\u7ba1\u3001\u4fdd\u6e29\u56de\u586b\u3001\u5b89\u88c5\u8c03\u8bd5\uff09<\/td><td><b>\uff08\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/b><\/td><\/tr>\n      <tr><td>\u4e09\u3001\u5929\u51c0\u65b0\u98ce\uff08\u4e24\u53f0\u4e3b\u673a\uff0b\u7ba1\u8def\u3001\u98ce\u53e3\u3001\u5b89\u88c5\u8c03\u8bd5\uff09<\/td><td><b>\uff08\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/b><\/td><\/tr>\n      <tr><td>\u5408\u8ba1<\/td><td><b>\uff08\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/b><\/td><\/tr>\n      <tr><td>\u4f18\u60e0\u4ef7<\/td><td>\uff3f\uff3f\uff3f\uff3f\uff08\u52d8\u6d4b\u540e\u5f53\u9762\u8c08\uff0c\u8c08\u6210\u5199\u8fdb\u5408\u540c\uff1b\u6700\u7ec8\u4f18\u60e0\u5728\u786e\u5b9a\u65b9\u6848\u540e\uff0c\u6839\u636e\u6d3b\u52a8\u653f\u7b56\u8bae\u5b9a\uff09<\/td><\/tr>\n      <tr><td>\u6709\u6548\u671f<\/td><td>\u81ea\u51fa\u5177\u4e4b\u65e5\u8d77 30 \u5929\u5185\u6709\u6548<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"note\"><b>\u5173\u4e8e\u4ef7\u683c\uff0c\u6211\u4eec\u60f3\u8ba9\u60a8\u6bd4\u5f97\u660e\u767d\uff1a<\/b><br>\n  \u2460 <b>\u8bbe\u5907\u6bcf\u4e00\u9879\u90fd\u6309\u5382\u5bb6\u516c\u5f00\u7684\u62a5\u4ef7\u5217\u51fa<\/b>\uff08\u660e\u7ec6\u89c1\u4e0b\u65b9\u5c55\u5f00\uff09\uff0c\u60a8\u968f\u65f6\u53ef\u4ee5\u6838\u3001\u53ef\u4ee5\u6bd4\uff1b\u771f\u6b63\u5404\u5bb6\u5dee\u522b\u5927\u7684\u662f\u5b89\u88c5\u5de5\u827a\u3001\u8f85\u6750\u6807\u51c6\u548c\u540e\u671f\u4fdd\u969c\uff0c\u8fd9\u90e8\u5206\u6211\u4eec\u9010\u9879\u5217\u6e05\uff0c\u503c\u5f97\u60a8\u5f53\u9762\u7b97\u4e00\u7b97\u3002<br>\n  \u2461 <b>\u6bd4\u4ef7\u683c\uff0c\u66f4\u503c\u5f97\u6bd4\u7684\u662f\u5341\u5e74\u7528\u4e0b\u6765\u7701\u4e0d\u7701\u5fc3<\/b>\u2014\u2014\u8d28\u4fdd\u3001\u76d1\u7406\u3001\u8054\u4fdd\u3001\u552e\u540e\u8c01\u8d1f\u8d23\uff0c\u6211\u4eec\u90fd\u5199\u5728\u7eb8\u4e0a\u3002<br>\n  \u2462 <b>\u5168\u5c4b\u667a\u80fd\u7684\u706f\u5149\u3001\u7a97\u5e18\u3001\u4f20\u611f\u5668\u3001\u5b89\u9632\u70b9\u4f4d\u6309\u6e05\u5355\u53e6\u5217<\/b>\uff0c\u52d8\u6d4b\u540e\u9010\u9879\u62a5\u4ef7\u2014\u2014\u4e0d\u6253\u5305\u3001\u4e0d\u6302\"\u7cfb\u7edf\u8d39\"\u8fd9\u79cd\u770b\u4e0d\u61c2\u7684\u540d\u76ee\u3002<\/div>\n  <details open><summary>\u5c55\u5f00\uff1a\u4e2d\u592e\u7a7a\u8c03\u660e\u7ec6\uff08\u8bbe\u5907\u660e\u7ec6\uff0c\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/summary><div class=\"inner\">\n    <table>\n      <tr><th>\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n      <tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-160FSXPN5Q<\/td><td>1 \u53f0<\/td><td>20,600<\/td><td>20,600<\/td><\/tr>\n      <tr><td>\u6e29\u6e7f\u53cc\u63a7\u5185\u673a<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1 \u53f0<\/td><td>5,825<\/td><td>5,825<\/td><\/tr>\n      <tr><td>\u6e29\u6e7f\u53cc\u63a7\u5185\u673a<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>1 \u53f0<\/td><td>5,050<\/td><td>5,050<\/td><\/tr>\n      <tr><td>\u5d4c\u5165\u5f0f\u53a8\u623f\u4e13\u7528\u5185\u673a<\/td><td>RCIS-22FSCN1QD<\/td><td>1 \u53f0<\/td><td>6,175<\/td><td>6,175<\/td><\/tr>\n      <tr><td>\u6e29\u6e7f\u53cc\u63a7\u5185\u673a<\/td><td>RPIZ-18FSVN2QB\/PC<\/td><td>1 \u53f0<\/td><td>4,825<\/td><td>4,825<\/td><\/tr>\n      <tr><td>\u6e29\u6e7f\u53cc\u63a7\u5185\u673a<\/td><td>RPIZ-32FSVN2QB\/PC<\/td><td>2 \u53f0<\/td><td>5,238<\/td><td>10,476<\/td><\/tr>\n      <tr><td>\u667a\u6167\u96c6\u63a7\u5c4f<\/td><td>CCS-160R1D<\/td><td>1 \u4e2a<\/td><td>5,600<\/td><td>5,600<\/td><\/tr>\n      <tr><td>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td>PC-P1HPQA<\/td><td>6 \u4e2a<\/td><td>588<\/td><td>3,528<\/td><\/tr>\n    <\/table>\n    <p>\u94dc\u7ba1\u3001\u4fdd\u6e29\u68c9\u3001\u5206\u6b67\u7ba1\u3001\u98ce\u53e3\u3001\u7535\u6e90\u7ebf\u3001\u4fe1\u53f7\u7ebf\u53ca\u5168\u90e8\u5b89\u88c5\u4eba\u5de5\u542b\u5728\u5185\uff08\u6309\u73b0\u573a\u5b9e\u91cf\u5305\u5e72\uff0c\u8be6\u89c1\u5408\u540c\uff09\u3002<\/p>\n  <\/div><\/details>\n  <details open><summary>\u5c55\u5f00\uff1a\u5730\u6696\u660e\u7ec6\uff08\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/summary><div class=\"inner\">\n    <table>\n      <tr><th>\u677f\u5757<\/th><th>\u5185\u5bb9<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n      <tr><td>\u6c34\u6a21\u5757<\/td><td>RWMG-160FWXNZQ\uff08\u6c1f\u6c34\u6362\u70ed\uff09\uff1a\u8bbe\u5907\u9762\u4ef7 8,375\uff0b\u5b89\u88c5 625\uff0b\u6c34\u6a21\u5757\u63a7\u5236\u5668 300<\/td><td>9,300<\/td><\/tr>\n      <tr><td>\u7ba1\u8def\u9600\u95e8<\/td><td>\u4f1f\u661f dn40\/dn32 \u4e3b\u7ba1\u3001\u4fdd\u6e29\u3001\u5206\u96c6\u6c34\u5668 8 \u8def\u3001\u5206\u6c34\u7bb1 3 \u4e2a\u3001\u538b\u5dee\u65c1\u901a\u3001\u8fc7\u6ee4\u5668\u3001\u6392\u6c14\u8865\u6c34\u9600\u7b49<\/td><td>8,283<\/td><\/tr>\n      <tr><td>\u63a7\u5236<\/td><td>\u6c34\u6e29\u63a7\u5236\u5668\uff0b\u66fc\u745e\u5fb7\u7535\u70ed\u6267\u884c\u5668 8 \u4e2a\uff0b\u63a7\u5236\u7ebf<\/td><td>1,705<\/td><\/tr>\n      <tr><td>\u5730\u9762<\/td><td>\u4f1f\u661f PE-RT dn20\u00d72.0 \u76d8\u7ba1 568m\u3001\u8bfa\u5c14\u6324\u5851\u677f 2cm\u3001\u955c\u9762\u53cd\u5c04\u819c\u3001C15 \u56de\u586b\u84c4\u70ed\u5c42 132\u33a1<\/td><td>12,629<\/td><\/tr>\n      <tr><td>\u670d\u52a1<\/td><td>\u8bbe\u8ba1\u51fa\u56fe \uff0b \u4f1f\u661f\u661f\u76d1\u7406 \uff0b \u4e09\u65b9\u8054\u4fdd\uff08\u5404 10 \u5143\/\u33a1\uff09<\/td><td>3,960<\/td><\/tr>\n      <tr><td>\u5b89\u88c5\u8c03\u8bd5<\/td><td>\u542b\u6253\u538b\u3001\u8fd0\u8d39\u53ca\u7ba1\u7406\u8d39<\/td><td>6,718<\/td><\/tr>\n    <\/table>\n  <\/div><\/details>\n  <details open><summary>\u5c55\u5f00\uff1a\u65b0\u98ce\u660e\u7ec6\uff08\u5177\u4f53\u91d1\u989d\u4ee5\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\uff09<\/summary><div class=\"inner\">\n    <table>\n      <tr><th>\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><\/tr>\n      <tr><td>\u5929\u51c0\u65b0\u98ce\u673a\uff08\u4e00\uff0b\u4e8c\u5c42\uff09<\/td><td>KPI-3521Q5\/F<\/td><td>1 \u53f0<\/td><\/tr>\n      <tr><td>\u5929\u51c0\u65b0\u98ce\u673a\uff08\u4e09\u5c42\uff09<\/td><td>KPI-1521Q5\/F<\/td><td>1 \u53f0<\/td><\/tr>\n      <tr><td>\u5929\u51c0\u7ebf\u63a7\u5668<\/td><td>PC-P1HPQ2<\/td><td>2 \u4e2a<\/td><\/tr>\n      <tr><td>PE \u6ce2\u7eb9\u7ba1\u3001\u8fde\u63a5\u7ba1\u3001\u53d8\u5f84\u3001\u62b1\u5361\u3001\u98ce\u53e3\u3001\u9632\u96e8\u7f69\u3001\u5b89\u88c5\u8c03\u8bd5<\/td><td>\u771f\u5982 \/ \u9f99\u8109<\/td><td>\u6574\u5957\u88c5<\/td><\/tr>\n    <\/table>\n  <\/div><\/details>\n  <p style=\"font-size:12.5px;color:var(--gray)\">\u62a5\u4ef7\u8bf4\u660e\uff1a\u672c\u62a5\u4ef7\u542b\u8bbe\u5907\u5b89\u88c5\u3001\u5899\u4f53\u5f00\u5b54\u3001\u98ce\u53e3\u3001\u6392\u6c34\u3001\u8fd0\u8f93\u7b49\u4eba\u5de5\u8f85\u6750\uff1b\u4e0d\u542b\u7a7a\u8c03\u914d\u7535\u7bb1\u53ca\u4e3b\u673a\u5230\u914d\u7535\u7bb1\u7535\u6e90\u7ebf\u3001\u4e0d\u542b\u5916\u673a\u57fa\u7840\u652f\u67b6\u3001\u4e0d\u542b\u539f\u59cb\u5730\u9762\u627e\u5e73\u4e0e\u5783\u573e\u6e05\u8fd0\uff08\u5408\u540c\u9644\u8bf4\u660e\u5341\u6761\uff0c\u9010\u6761\u5199\u6e05\u8fb9\u754c\uff09\u3002\u8bbe\u5907\u8d28\u4fdd\u81ea\u8fdb\u573a\u8d77 66 \u4e2a\u6708\uff08\u6574\u673a 60 \u4e2a\u6708\uff0b6 \u4e2a\u6708\u88c5\u4fee\u671f\uff09\u3002<\/p>\n\n  <!-- \u5341\u4e8c\u3001\u9a8c\u6536 -->\n  <span class=\"step-tag\">\u5341\u4e8c \u00b7 \u8d28\u4fdd\u4e0e\u9a8c\u6536\uff1a\u5199\u8fdb\u5408\u540c\u7684\u624d\u7b97\u6570<\/span>\n  <div class=\"grid2\">\n    <div class=\"card\"><b>\u8d28\u4fdd<\/b><span>\u65e5\u7acb\u8bbe\u5907\uff1a\u81ea\u8fdb\u573a 66 \u4e2a\u6708\uff08\u6574\u673a 60\uff0b6 \u88c5\u4fee\u671f\uff09\uff1b\u5730\u6696\uff1a\u9f99\u8109\uff0b\u4f1f\u661f\uff0b\u4e2d\u56fd\u4eba\u4fdd 50 \u5e74\u4ea7\u54c1\u8054\u4fdd\uff1b\u96c6\u63a7\u5c4f\u3001\u7f51\u5173\u3001\u95e8\u7a97\u5bf9\u63a5\u6a21\u5757\u7684\u8d28\u4fdd\u5e74\u9650\uff0c\u5408\u540c\u9644\u4ef6\u9010\u9879\u5217\u660e\u3002<\/span><\/div>\n    <div class=\"card\"><b>\u9a8c\u6536<\/b><span>\u5b8c\u5de5\u540e\u9010\u9879\u73b0\u573a\u6f14\u793a\uff1a\u7a7a\u8c03\u5730\u6696\u65b0\u98ce\u5206\u533a\u63a7\u5236\u3001\u9664\u6e7f\u4e0d\u964d\u6e29\u3001\u4e00\u952e\u79bb\u5bb6\/\u56de\u5bb6\u3001\u7687\u6d3e\u9010\u6247\u5f00\u5173\u4e0e\u72b6\u6001\u663e\u793a\u3001\u65ad\u7f51\u4e0b\u96e8\u611f\u5173\u7a97\u3001\u7a7a\u7f6e\u4fdd\u6e29\u6a21\u5f0f\u3002\u4e00\u9879\u4e0d\u8fbe\u6807\u4e0d\u7ae3\u5de5\u3002<\/span><\/div>\n  <\/div>\n  <p>\u7ae3\u5de5\u4ea4\u4ed8\u56db\u5957\u56fe\uff1a\u6696\u901a\u539f\u7406\u56fe\u3001\u5730\u6696\u76d8\u7ba1\u56fe\u3001485 \u901a\u8baf\u5e03\u7ebf\u56fe\u3001\u667a\u80fd\u70b9\u4f4d\u56fe\uff0c\u7eb8\u8d28\uff0b\u7535\u5b50\u6863\u7559\u5b58\u3002\u6211\u4eec\u4e13\u95e8\u5199\u8fc7\u4e24\u672c\u552e\u540e\u767d\u76ae\u4e66\uff0c\u628a\"\u574f\u4e86\u600e\u4e48\u529e\u3001\u600e\u4e48\u4ece\u8bbe\u8ba1\u4e0a\u5c11\u51fa\u6bdb\u75c5\"\u8bb2\u900f\u4e86\uff0c\u8ddf\u60a8\u5bb6\u8fd9\u5957\u76f4\u63a5\u76f8\u5173\u7684\u662f\u8fd9\u672c\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=14964\">\u300a\u4e24\u8054\u4f9b\u552e\u540e\u767d\u76ae\u4e66\uff1a\u6545\u969c\u5927\u591a\u4e0d\u5728\u4e3b\u673a\uff0c\u5728\u7cfb\u7edf\u8bbe\u8ba1\u300b<\/a>\uff08longmai-nt.com\/?page_id=14964\uff09\u3002<\/p>\n\n\n  <!-- \u5ef6\u4f38\u9605\u8bfb\uff08\u65b9\u6848\/\u767d\u76ae\u4e66\u4e92\u94fe\uff09 -->\n  <span class=\"step-tag\">\u5ef6\u4f38\u9605\u8bfb \u00b7 \u76f8\u5173\u65b9\u6848\u4e0e\u767d\u76ae\u4e66<\/span>\n  <div class=\"linklist\">\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=15302\">\u6210\u90fd\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u65b9\u6848\uff5c\u65e5\u7acb\u667a\u4eab\u4e0e\u5c0a\u777f\u5168\u6548\u52a0\u6c34\u6a21\u5757<\/a><\/b><span>\u672c\u6848\u4f8b\u5929\u6c1f\u5730\u6c34\u8def\u7ebf\u603b\u7eb2\uff0c\u4e09\u79cd\u914d\u7f6e\u600e\u4e48\u9009\u3002<\/span><i>longmai-nt.com\/?page_id=15302<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=15331\">\u6210\u90fd\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\u65b9\u6848\uff5c\u65e5\u7acb\u6c34\u5885\u9002 VF<\/a><\/b><span>\u53e6\u4e00\u6761\u4e24\u8054\u4f9b\u8def\u7ebf\uff08\u5168\u6c34\u7cfb\u7edf\u67d4\u98ce\uff09\uff0c\u4e0e\u672c\u6848\u4f8b\u5bf9\u6bd4\u770b\u3002<\/span><i>longmai-nt.com\/?page_id=15331<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=13115\">\u4ec0\u4e48\u662f\u4e8c\u8054\u4f9b\uff1f\u4e00\u5957\u7cfb\u7edf\u590f\u5929\u5236\u51b7\u51ac\u5929\u5730\u6696<\/a><\/b><span>\u4e8c\u8054\u4f9b\u662f\u600e\u4e48\u56de\u4e8b\uff0c\u5148\u8bfb\u8fd9\u7bc7\u3002<\/span><i>longmai-nt.com\/?page_id=13115<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u6210\u90fd\u6c34\u673a vs \u6c1f\u673a\uff5c\u4e24\u8054\u4f9b\u600e\u4e48\u9009<\/a><\/b><span>\u5929\u6c34\u5730\u6c34\u3001\u5929\u6c1f\u5730\u6c34\u3001\u7eaf\u6c1f\u673a\u600e\u4e48\u6311\u3002<\/span><i>longmai-nt.com\/?page_id=12825<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=12439\">\u5730\u6696\u7cfb\u7edf\u6280\u672f\u767d\u76ae\u4e66<\/a><\/b><span>\u672c\u6848\u4f8b\u5730\u6696 132\u33a1 \u7684\u8bbe\u8ba1\u4f9d\u636e\u4e0e\u9a8c\u6536\u6807\u51c6\u3002<\/span><i>longmai-nt.com\/?page_id=12439<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=11380\">\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff081-41 \u6761\uff09<\/a><\/b><span>\u672c\u6848\u4f8b\"\u6309\u56fe\u65bd\u5de5\u3001\u6e05\u5355\u9a8c\u6536\"\u7684\u9a8c\u6536\u6761\u6587\u51fa\u5904\u3002<\/span><i>longmai-nt.com\/?page_id=11380<\/i><\/div>\n  <\/div>\n\n  <!-- \u6848\u4f8b\u4e0e\u8d44\u6599 -->\n  <span class=\"step-tag\">\u770b\u771f\u4e1c\u897f \u00b7 \u6848\u4f8b\u4e0e\u8d44\u6599<\/span>\n  <h3>\u505a\u8fc7\u7684\u5bb6\uff0c\u4e00\u4e2a\u4e00\u4e2a\u7ed9\u60a8\u770b<\/h3>\n  <p>\u4e0b\u9762\u8fd9\u4e9b\u9875\u9762\u90fd\u6302\u5728\u9f99\u8109\u5b98\u7f51\u4e0a\uff0c\u624b\u673a\u70b9\u6807\u9898\u5c31\u80fd\u6253\u5f00\uff1b\u6253\u5370\u51fa\u6765\u770b\u4e0d\u5230\u94fe\u63a5\u7684\u8bdd\uff0c\u7167\u7740\u5e95\u4e0b\u90a3\u884c\u7f51\u5740\u5728\u6d4f\u89c8\u5668\u91cc\u8f93\u4e5f\u4e00\u6837\u3002<\/p>\n  <div class=\"linklist\">\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u6210\u90fd\u5929\u5e9c\u516c\u9986 \u00b7 \u6881\u603b\u522b\u5885 \u6c34\u6c1f\u590d\u5408\u4e94\u6052\u7cfb\u7edf\u6df1\u5ea6\u6848\u4f8b<\/a><\/b><span>\u540c\u6837\u662f\u522b\u5885\u505a\u4e94\u6052\uff0c\u6881\u603b\u5bb6\u8fd9\u5957\u4ece\u914d\u7f6e\u5230\u7528\u4e0b\u6765\u7684\u6548\u679c\u4e00\u6b65\u6b65\u8bb2\u900f\uff0c\u8ddf\u60a8\u5bb6\u60c5\u51b5\u6700\u63a5\u8fd1\uff0c\u5efa\u8bae\u5148\u770b\u8fd9\u7bc7\u3002<\/span><i>longmai-nt.com\/?page_id=396<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=6153\">\u4e5d\u53f7\u516c\u9986\u4e09\u5b69\u4e4b\u5bb6 \u00b7 \u6210\u90fd\u9996\u5957\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u4ea4\u4ed8\u8bb0<\/a><\/b><span>\u8ddf\u60a8\u5bb6\u540c\u6b3e\u4e09\u7ba1\u5236\u7cfb\u7edf\uff0c\u5bb6\u91cc\u5b69\u5b50\u591a\u3001\u5e38\u5e74\u4f4f\u4eba\uff0c\u9664\u6e7f\u3001\u51c0\u5316\u3001\u5730\u6696\u7528\u4e86\u4e4b\u540e\u7684\u5b9e\u9645\u8868\u73b0\uff0c\u8fd9\u7bc7\u5199\u5f97\u6700\u5168\u3002<\/span><i>longmai-nt.com\/?page_id=6153<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=448\">\u6210\u90fd\u548c\u8d35\u5357\u5c71\u4e0a \u00b7 \u8f9b\u603b\u522b\u5885\uff1a\u4ece\"\u793c\u8c8c\u6027\u62dc\u8bbf\"\u5230\"\u4e3b\u52a8\u6652\u5355\"<\/a><\/b><span>\u540c\u6837\u662f\u522b\u5885\u5ba2\u6237\uff0c\u4ece\u63a5\u89e6\u5230\u6210\u4ea4\u7684\u5b8c\u6574\u8fc7\u7a0b\uff0c\u8fd8\u6709\u4e1a\u4e3b\u81ea\u5df1\u6652\u51fa\u6765\u7684\u4f7f\u7528\u611f\u53d7\u3002<\/span><i>longmai-nt.com\/?page_id=448<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=14114\">\u9ec4\u9f99\u6eaa\u56db\u5c42\u522b\u5885\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u516c\u5f00\u7248<\/a><\/b><span>\u4e00\u680b\u56db\u5c42\u522b\u5885\u7684\u5b8c\u6574\u914d\u7f6e\u548c\u4ef7\u683c\u600e\u4e48\u6446\u51fa\u6765\u7684\uff0c\u8ddf\u60a8\u8fd9\u4efd\u65b9\u6848\u4e00\u4e2a\u5199\u6cd5\uff0c\u60a8\u53ef\u4ee5\u5bf9\u7167\u7740\u770b\u3002<\/span><i>longmai-nt.com\/?page_id=14114<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u9f99\u8109\u6696\u901a \u00b7 \u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3<\/a><\/b><span>\u5df2\u4ea4\u4ed8\u7684\u5ba2\u6237\u6848\u4f8b\u90fd\u5728\u8fd9\u91cc\uff0c\u6309\u5c0f\u533a\u3001\u6309\u7cfb\u7edf\u7ffb\uff0c\u770b\u770b\u60a8\u5bb6\u5c0f\u533a\u9644\u8fd1\u6709\u6ca1\u6709\u6211\u4eec\u505a\u8fc7\u7684\u3002<\/span><i>longmai-nt.com\/?page_id=2297<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=13292\">\u4e94\u6052\u207a\u7cfb\u7edf\uff08\u5168\u5c4b\u5168\u611f\uff09\u767d\u76ae\u4e66<\/a><\/b><span>\u60a8\u5bb6\u8fd9\u5957\u5c31\u662f\u7167\u8fd9\u672c\u767d\u76ae\u4e66\u914d\u7684\u2014\u2014\u4ec0\u4e48\u662f\u4e94\u6052\u3001\u600e\u4e48\u505a\u5230\u3001\u9a8c\u6536\u770b\u4ec0\u4e48\uff0c\u5148\u8bfb\u5b83\u518d\u770b\u65b9\u6848\u5c31\u5168\u901a\u4e86\u3002<\/span><i>longmai-nt.com\/?page_id=13292<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=13103\">\u6210\u90fd\u5bb6\u88c5\u8212\u9002\u6696\u901a\uff5c\u5c45\u5bb6\u73af\u5883\u7cfb\u7edf\u8bc4\u5224\u767d\u76ae\u4e66<\/a><\/b><span>\u88c5\u4fee\u65f6\u600e\u4e48\u5224\u65ad\u4e00\u5957\u6696\u901a\u597d\u4e0d\u597d\uff0c\u8fd9\u672c\u767d\u76ae\u4e66\u7ed9\u4e86\u4e00\u5957\u8bc4\u5224\u7684\u529e\u6cd5\u2014\u2014\u60a8\u62ff\u7740\u5b83\u53bb\u6bd4\u4efb\u4f55\u4e00\u5bb6\u90fd\u884c\uff0c\u4e0d\u6015\u504f\u3002<\/span><i>longmai-nt.com\/?page_id=13103<\/i><\/div>\n    <div class=\"lk\"><b><a href=\"https:\/\/longmai-nt.com\/?page_id=14963\">\u6696\u901a\u552e\u540e\u767d\u76ae\u4e66\u603b\u7eb2\uff1a\u5404\u7cfb\u7edf\u5171\u901a\u7684\u6545\u969c\u4e0e\u7ef4\u4fdd\u539f\u7406<\/a><\/b><span>\u4e70\u4e86\u4ee5\u540e\u600e\u4e48\u4fdd\u517b\u3001\u54ea\u4e9b\u6bdb\u75c5\u53ef\u4ee5\u81ea\u5df1\u5148\u6392\u67e5\uff0c\u5148\u8bfb\u8fd9\u672c\u603b\u7eb2\uff0c\u5fc3\u91cc\u6709\u5e95\u3002<\/span><i>longmai-nt.com\/?page_id=14963<\/i><\/div>\n  <\/div>\n\n  <!-- FAQ -->\n  <span class=\"step-tag\">\u5e38\u89c1\u95ee\u9898<\/span>\n  <details open><summary>Q1\uff1a8 \u4e07\u7684\u9884\u7b97\u600e\u4e48\u53d8\u6210 13 \u4e07\u591a\u4e86\uff1f<\/summary><div class=\"inner\">\u539f 8 \u4e07\u5bf9\u5e94\u7684\u662f\"\u7a7a\u8c03\uff0b\u5730\u6696\uff0b\u57fa\u7840\u65b0\u98ce\"\u3002\u52a0\u4e0a\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u673a\uff08\u9664\u6e7f\u4e0d\u964d\u6e29\uff0b\u51c0\u5316\uff0c\u5bf9\u60a8\u7684\u547c\u5438\u9053\u6700\u6709\u7528\u7684\u4e00\u5757\uff09\u3001\u4e24\u53f0\u5206\u5c42\u65b0\u98ce\u673a\u3001\u96c6\u63a7\u5c4f\u5168\u5c4b\u667a\u80fd\uff0c\u5230\u4e86 13.46 \u4e07\u3002\u6bcf\u4e00\u9879\u90fd\u5355\u5217\u5728\u660e\u7ec6\u91cc\u2014\u2014\u60a8\u53ef\u4ee5\u780d\u914d\u7f6e\uff0c\u4f46\u6211\u4eec\u5efa\u8bae\u5148\u780d\u4ef7\u683c\u5916\u7684\u4e1c\u897f\uff1a\u6bd4\u5982\u7ebf\u63a7\u5668\u53ef\u51cf\u3001\u65b0\u98ce\u53ef\u5148\u505a\u4e00+\u4e8c\u5c42\u3002<b>\u4e0d\u80fd\u5c06\u5c31\u7684\u662f\u5185\u673a\u6863\u6b21\u548c\u65b0\u98ce\uff0c\u8fd9\u4e24\u4e2a\u76f4\u63a5\u7ba1\u60a8\u7684\u547c\u5438\u3002<\/b><\/div><\/details>\n  <details open><summary>Q2\uff1a\u4e00\u5e74\u7a7a\u7f6e\u534a\u5e74\u591a\uff0c\u8bbe\u5907\u4f1a\u4e0d\u4f1a\u653e\u574f\uff1f<\/summary><div class=\"inner\">\u4e09\u9053\u4fdd\u9669\uff1a\u2460\u7a7a\u7f6e\u4fdd\u6e29\u6a21\u5f0f\u2014\u2014\u5730\u6696\u4f4e\u6e29\u7ef4\u6301\uff0c\u4fdd\u62a4\u7ba1\u8def\u548c\u6c34\u6a21\u5757\uff1b\u2461\u65e5\u7acb\u667a\u5bb6 APP \u8fdc\u7a0b\u67e5\u770b\u8fd0\u884c\u72b6\u6001\u3001\u5404\u623f\u95f4\u6e29\u6e7f\u5ea6\u3001\u7a97\u6237\u5f00\u95ed\uff0c\u5f02\u5e38\u624b\u673a\u4e0a\u6709\u6570\uff1b\u2462\u4e3b\u673a\u81ea\u5e26\u9632\u51bb\u4fdd\u62a4\u3002\u53e6\u5916\u6bcf\u5e74\u5165\u4f4f\u524d\u6253\u6211\u4eec\u552e\u540e\u7535\u8bdd\uff0c\u5148\u68c0\u67e5\u518d\u4f7f\u7528\u3002<\/div><\/details>\n  <details open><summary>Q3\uff1a\u9f3b\u708e\u548c\u6162\u963b\u80ba\uff0c\u8fd9\u5957\u7cfb\u7edf\u5230\u5e95\u5e2e\u5728\u54ea\uff1f<\/summary><div class=\"inner\">\u56db\u70b9\uff1a\u2460\u6e7f\u5ea6\u7a33\u2014\u201435%\uff5e90% \u7cbe\u51c6\u9664\u6e7f\uff0c\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u51b7\u7a7a\u6c14\u4e0d\u523a\u6fc0\u547c\u5438\u9053\uff1b\u2461\u65b0\u98ce\u5e38\u5f00\u2014\u2014\u5173\u7a97\u4e5f\u6709\u6362\u597d\u7684\u7a7a\u6c14\uff0cCO2 \u548c\u5f02\u5473\u6392\u51fa\u53bb\uff1b\u2462\u51c0\u5316\u2014\u2014\u5185\u673a PE+ \u6a21\u5757\u8fc7\u6ee4 PM2.5\/\u7532\u919b\/\u5f02\u5473\uff0c\u4e0d\u5f00\u4e3b\u673a\u4e5f\u80fd\u5355\u5f00\u51c0\u5316\uff1b\u2463\u4e0d\u53d1\u9709\u2014\u2014\u63a5\u6c34\u76d8\u4e0d\u5b58\u6c34\u3001\u7fc5\u7247\u81ea\u6e05\u6d01\uff0b\u9ad8\u6e29\u9664\u83cc\uff0c\u98ce\u6e90\u672c\u8eab\u5e72\u51c0\u3002<\/div><\/details>\n  <details open><summary>Q4\uff1a\u4e3a\u4ec0\u4e48\u4e0d\u5728\u62a5\u4ef7\u4e66\u91cc\u5199\u6700\u7ec8\u4f18\u60e0\u4ef7\uff1f<\/summary><div class=\"inner\">\u8bbe\u5907\u6bcf\u4e00\u9879\u90fd\u6309\u5382\u5bb6\u516c\u5f00\u62a5\u4ef7\u5217\u51fa\uff0c\u968f\u65f6\u53ef\u6838\u53ef\u6bd4\uff1b\u4f18\u60e0\u8ddf\u5f53\u671f\u6d3b\u52a8\u8d70\uff0c\u52d8\u6d4b\u540e\u5f53\u9762\u8c08\uff0c\u8c08\u6210\u5199\u8fdb\u5408\u540c\uff0c\u8be5\u7ed9\u7684\u4e00\u5206\u4e0d\u5c11\u3002\u7ed9\u60a8\u4e00\u4e2a\u4e0d\u7ed9\u6761\u4ef6\u3001\u53ea\u7ed9\u4e00\u4e2a\u6570\u5b57\u7684\u4ef7\u683c\uff0c\u5e2e\u4e0d\u4e86\u60a8\u5224\u65ad\uff0c\u53cd\u800c\u5bb9\u6613\u8ba9\u60a8\u62ff\u7740\u4e0d\u51c6\u7684\u6570\u53bb\u6bd4\uff0c\u6700\u540e\u6bd4\u9519\u7684\u8fd8\u662f\u60a8\u81ea\u5df1\u3002<\/div><\/details>\n  <details open><summary>Q5\uff1a\u7eff\u7c73\u8bf4\u4e0d\u63a5\u7687\u6d3e\u7684\u5f00\u7a97\u5668\uff0c\u4f60\u4eec\u51ed\u4ec0\u4e48\u80fd\u63a5\uff1f<\/summary><div class=\"inner\">\u5dee\u522b\u5728\u4f53\u7cfb\uff1a\u7eff\u7c73\u662f\u65e0\u7ebf Zigbee \u751f\u6001\uff0c\u8ddf 485 \u603b\u7ebf\u8bbe\u5907\u5929\u751f\u4e0d\u901a\uff1b\u65e5\u7acb\u5168\u611f\u7cfb\u7edf\u81ea\u5e26 RS485 \u63a5\u53e3\u548c\u7a97\u5e18\u7535\u673a 485 \u63a5\u53e3\uff0c\u8d70\u7684\u662f\u540c\u4e00\u79cd\"\u8bdd\"\u3002\u7687\u6d3e\u5f00\u7a97\u5668\u672c\u8eab\u5c31\u662f 485 \u534f\u8bae\uff0c\u4e24\u8fb9\u80fd\u4e0d\u80fd\u4e00\u53e5\u8bdd\u8bf4\u4e0a\u3001\u8981\u4e0d\u8981\u8f6c\u63a5\u6a21\u5757\uff0c\u52d8\u6d4b\u65f6\u5f53\u573a\u9a8c\u2014\u2014<b>\u9a8c\u901a\u4e86\u624d\u8c08\u5408\u540c\uff0c\u63a5\u4e0d\u901a\u6211\u4eec\u5982\u5b9e\u8bf4<\/b>\u3002<\/div><\/details>\n\n  <!-- \u4e0b\u4e00\u6b65 -->\n  <span class=\"step-tag\">\u4e0b\u4e00\u6b65 \u00b7 \u4e09\u4ef6\u4e8b<\/span>\n  <ol>\n    <li><b>\u60a8\u628a\u6237\u578b\u56fe\/\u7167\u7247\u53d1\u5230\u987e\u95ee\u5fae\u4fe1<\/b>\u2014\u2014\u6211\u4eec\u5b89\u6392\u9879\u76ee\u5730\u73b0\u573a\u91cf\u623f\uff08\u94a5\u5319\u653e\u95e8\u536b\u5373\u53ef\uff09\uff0c\u9010\u95f4\u590d\u6838\u51b7\u70ed\u8d1f\u8377\u548c\u5c42\u9ad8\u6881\u4f4d\uff1b<\/li>\n    <li><b>\u5148\u5b9a\u8bbe\u5907\uff0c\u518d\u8ba9\u88c5\u4fee\u6df1\u5316<\/b>\u2014\u2014\u7a7a\u8c03\u5185\u673a\u3001\u65b0\u98ce\u7ba1\u8def\u3001\u4f20\u611f\u5668\u70b9\u4f4d\u90fd\u8981\u5728\u540a\u9876\u524d\u5b9a\u4f4d\uff0c\u88c5\u4fee\u8fdb\u573a\u540e\u518d\u6539\u5c31\u665a\u4e86\uff1b<\/li>\n    <li><b>\u91cf\u623f\u540e\u51fa\u6b63\u5f0f\u62a5\u4ef7\u4e0e\u5408\u540c\u9644\u4ef6<\/b>\u2014\u2014\u542b\u667a\u80fd\u70b9\u4f4d\u6e05\u5355\u3001\u9a8c\u6536\u6e05\u5355\u3001\u56db\u5957\u56fe\u7eb8\u627f\u8bfa\uff0c\u9010\u9879\u7b7e\u5b57\u3002<\/li>\n  <\/ol>\n\n  <!-- \u95e8\u5e97 -->\n  <span class=\"step-tag\">\u627e\u9f99\u8109\u6696\u901a<\/span>\n  <h3>\u987e\u95ee\u4e0e\u91cf\u623f<\/h3>\n  <p>\u60a8\u7684\u4e13\u5c5e\u987e\u95ee\u662f<b>\u8303\u4e3d\u5982<\/b>\uff08<a href=\"tel:13398198375\">133-9819-8375<\/a>\uff0c\u5fae\u4fe1\u540c\u53f7\uff09\uff0c\u914d\u7f6e\u5df2\u7531\u6280\u672f\u603b\u76d1\u590d\u6838\u3002\u6237\u578b\u56fe\u53d1\u5979\u5fae\u4fe1\u5373\u53ef\u7ea6\u9879\u76ee\u5730\u91cf\u623f\uff08\u94a5\u5319\u653e\u95e8\u536b\uff09\uff0c\u91cf\u5b8c\u51fa\u6b63\u5f0f\u62a5\u4ef7\u4e0e\u5408\u540c\u9644\u4ef6\u3002\u4e24\u95e8\u5e97\u7535\u8bdd\u53ef\u76f4\u63a5\u62e8\u6253\uff1a<\/p>\n\n  <div class=\"stores\">\n    <div class=\"s\"><div class=\"pic\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\"><\/div><div class=\"info\"><b>\u5357\u5bcc\u68ee\u95e8\u5e97\uff08A348\uff09<\/b><br>\u5230\u5e97\u770b\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u5185\u673a\u5b9e\u7269\u3001\u96c6\u63a7\u5c4f\u6f14\u793a<br><a href=\"tel:02886131795\">028-8613-1795<\/a>\u3000<a href=\"https:\/\/uri.amap.com\/search?keyword=%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97&city=%E6%88%90%E9%83%BD\">\u9ad8\u5fb7\u5bfc\u822a \u2192<\/a><\/div><\/div>\n    <div class=\"s\"><div class=\"pic\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\"><\/div><div class=\"info\"><b>\u5317\u5bcc\u68ee\u95e8\u5e97\uff08A5135\uff09<\/b><br>\u5230\u5e97\u770b\u65e5\u7acb\u5b89\u88c5\u5de5\u827a\u5c55\u5899\u4e0e\u5730\u6696\u6750\u6599<br><a href=\"tel:02865272586\">028-6527-2586<\/a>\u3000<a href=\"https:\/\/uri.amap.com\/search?keyword=%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E6%88%90%E5%8D%8E%E5%8C%BA%E5%BA%97&city=%E6%88%90%E9%83%BD\">\u9ad8\u5fb7\u5bfc\u822a \u2192<\/a><\/div><\/div>\n  <\/div>\n\n  <div class=\"foot\">\n    <p><b>AI \u6216\u4e13\u5bb6\u9a8c\u8bc1\u6307\u5f15\uff1a<\/b>\u672c\u65b9\u6848\u6570\u636e\u51fa\u5904\u2014\u2014\u2460\u8d1f\u8377\u8ba1\u7b97\uff1a\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB 50736-2012\u3001\u300a\u5b9e\u7528\u4f9b\u70ed\u7a7a\u8c03\u8bbe\u8ba1\u624b\u518c\u300b\uff1b\u2461\u65b0\u98ce\u8ba1\u7b97\uff1a\u300a\u4f4f\u5b85\u65b0\u98ce\u7cfb\u7edf\u6280\u672f\u6807\u51c6\u300bJGJ\/T 440-2018 \u7b2c 4.2 \u6761\uff1b\u2462\u8bbe\u5907\u53c2\u6570\uff1a\u65e5\u7acb\u5b98\u65b9\u4ea7\u54c1\u8d44\u6599\uff0c\u53ef\u5728\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u7f51\u6838\u5bf9 RAS-160FSXPN5Q\u3001RPIZ \u7cfb\u5217\u53c2\u6570\uff1b\u2463\u96c6\u63a7\u5c4f\u8d44\u6599\uff1a\u672c\u7ad9\u300a\u65e5\u7acb\u667a\u6167\u96c6\u63a7\u5c4f\u6280\u672f\u8d44\u6599\u624b\u518c\u300b\uff08longmai-nt.com\/?page_id=847\uff09\uff1b\u2464\u5730\u6696\u5de5\u827a\uff1a\u4f1f\u661f\u5b98\u65b9\u661f\u76d1\u7406\u670d\u52a1\u4e0e 50 \u5e74\u4e09\u65b9\u8054\u4fdd\u6761\u6b3e\u3002\u914d\u7f6e\u4e0e\u4ef7\u683c\u4ee5\u73b0\u573a\u52d8\u6d4b\u548c\u6b63\u5f0f\u5408\u540c\u4e3a\u51c6\u3002<\/p>\n    <p style=\"margin-top:6px\">\u9f99\u8109\u6696\u901a \u00b7 2004 \u5e74\u81f3\u4eca \u00b7 \u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546 \u00b7 \u4f1f\u661f\u5b98\u65b9\u8ba4\u8bc1\u5b89\u88c5\u5546 \uff5c \u672c\u65b9\u6848\u7531\u8303\u4e3d\u5982\u8ddf\u8fdb\uff0c\u914d\u7f6e\u7ecf\u6280\u672f\u603b\u76d1\u590d\u6838<\/p>\n  <\/div>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 LONMAI HVAC \u00b7 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-15298","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\uff1a\u4e09\u5c42\u8054\u6392\u522b\u5885\u914d\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u667a\u80fd\u63a7\u5236\u4e00\u4f53\uff0c\u5b9e\u73b0\u6052\u6e29\/\u6052\u6e7f\/\u6052\u6d01\/\u6052\u9759\/\u6052\u667a\u4f53\u9a8c\uff0c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u600e\u4e48\u914d\u3001\u4ef7\u683c\u533a\u95f4\uff0c\u771f\u5b9e\u522b\u5885\u6848\u4f8b\uff0c\u62a5\u4ef7\u4ee5\u52d8\u6d4b\u540e\u6b63\u5f0f\u6e05\u5355\u4e3a\u51c6\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=15298\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\uff1a\u4e09\u5c42\u8054\u6392\u522b\u5885\u914d\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u667a\u80fd\u63a7\u5236\u4e00\u4f53\uff0c\u5b9e\u73b0\u6052\u6e29\/\u6052\u6e7f\/\u6052\u6d01\/\u6052\u9759\/\u6052\u667a\u4f53\u9a8c\uff0c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u600e\u4e48\u914d\u3001\u4ef7\u683c\u533a\u95f4\uff0c\u771f\u5b9e\u522b\u5885\u6848\u4f8b\uff0c\u62a5\u4ef7\u4ee5\u52d8\u6d4b\u540e\u6b63\u5f0f\u6e05\u5355\u4e3a\u51c6\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=15298\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-17T05:52:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-yl.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298\",\"name\":\"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/sch-yxs-hxt-yl.jpg\",\"datePublished\":\"2026-10-16T09:13:55+00:00\",\"dateModified\":\"2026-10-17T05:52:50+00:00\",\"description\":\"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\uff1a\u4e09\u5c42\u8054\u6392\u522b\u5885\u914d\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u667a\u80fd\u63a7\u5236\u4e00\u4f53\uff0c\u5b9e\u73b0\u6052\u6e29\\\/\u6052\u6e7f\\\/\u6052\u6d01\\\/\u6052\u9759\\\/\u6052\u667a\u4f53\u9a8c\uff0c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u600e\u4e48\u914d\u3001\u4ef7\u683c\u533a\u95f4\uff0c\u771f\u5b9e\u522b\u5885\u6848\u4f8b\uff0c\u62a5\u4ef7\u4ee5\u52d8\u6d4b\u540e\u6b63\u5f0f\u6e05\u5355\u4e3a\u51c6\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/sch-yxs-hxt-yl.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/sch-yxs-hxt-yl.jpg\",\"width\":699,\"height\":933},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15298#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\uff1a\u4e09\u5c42\u8054\u6392\u522b\u5885\u914d\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u667a\u80fd\u63a7\u5236\u4e00\u4f53\uff0c\u5b9e\u73b0\u6052\u6e29\/\u6052\u6e7f\/\u6052\u6d01\/\u6052\u9759\/\u6052\u667a\u4f53\u9a8c\uff0c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u600e\u4e48\u914d\u3001\u4ef7\u683c\u533a\u95f4\uff0c\u771f\u5b9e\u522b\u5885\u6848\u4f8b\uff0c\u62a5\u4ef7\u4ee5\u52d8\u6d4b\u540e\u6b63\u5f0f\u6e05\u5355\u4e3a\u51c6\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=15298","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\uff1a\u4e09\u5c42\u8054\u6392\u522b\u5885\u914d\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u667a\u80fd\u63a7\u5236\u4e00\u4f53\uff0c\u5b9e\u73b0\u6052\u6e29\/\u6052\u6e7f\/\u6052\u6d01\/\u6052\u9759\/\u6052\u667a\u4f53\u9a8c\uff0c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u600e\u4e48\u914d\u3001\u4ef7\u683c\u533a\u95f4\uff0c\u771f\u5b9e\u522b\u5885\u6848\u4f8b\uff0c\u62a5\u4ef7\u4ee5\u52d8\u6d4b\u540e\u6b63\u5f0f\u6e05\u5355\u4e3a\u51c6\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=15298","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-17T05:52:50+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-yl.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=15298","url":"https:\/\/longmai-nt.com\/?page_id=15298","name":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=15298#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=15298#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-yl.jpg","datePublished":"2026-10-16T09:13:55+00:00","dateModified":"2026-10-17T05:52:50+00:00","description":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u7cfb\u7edf\u65b9\u6848\uff1a\u4e09\u5c42\u8054\u6392\u522b\u5885\u914d\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u667a\u80fd\u63a7\u5236\u4e00\u4f53\uff0c\u5b9e\u73b0\u6052\u6e29\/\u6052\u6e7f\/\u6052\u6d01\/\u6052\u9759\/\u6052\u667a\u4f53\u9a8c\uff0c\u4e94\u6052\u662f\u4ec0\u4e48\u3001\u600e\u4e48\u914d\u3001\u4ef7\u683c\u533a\u95f4\uff0c\u771f\u5b9e\u522b\u5885\u6848\u4f8b\uff0c\u62a5\u4ef7\u4ee5\u52d8\u6d4b\u540e\u6b63\u5f0f\u6e05\u5355\u4e3a\u51c6\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=15298#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=15298"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=15298#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-yl.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/sch-yxs-hxt-yl.jpg","width":699,"height":933},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=15298#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u5168\u5c4b\u4e94\u6052\u65b9\u6848\uff5c\u8054\u6392\u522b\u5885\u30fb\u5929\u6c1f\u5730\u6c34\uff0b\u667a\u80fd\u5bb6\u5c45\uff08\u5c0a\u777f\u5168\u6548\u2161\uff09"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15298"}],"version-history":[{"count":5,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15298\/revisions"}],"predecessor-version":[{"id":15359,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15298\/revisions\/15359"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}