{"id":15413,"date":"2026-10-17T19:00:26","date_gmt":"2026-10-17T11:00:26","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=15413"},"modified":"2026-10-20T18:17:35","modified_gmt":"2026-10-20T10:17:35","slug":"%e6%98%8e%e8%a3%85%e6%9a%96%e6%b0%94%e6%96%bd%e5%b7%a5%e5%ae%89%e8%a3%85%e8%b0%83%e8%af%95%e9%aa%8c%e6%94%b6%e5%85%a8%e6%b5%81%e7%a8%8b","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=15413","title":{"rendered":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6"},"content":{"rendered":"\n<div class=\"entry-content clear\" data-ast-blocks-layout=\"true\" itemprop=\"text\">\n\t\n<div class=\"lmnt-prop\">\n<style>\n.lmnt-prop{--brand:#0f2a52;--brand2:#1d4e89;--accent:#c8102e;--green:#1f8a4c;--gray:#6b7280;--bg:#f4f6fa;--card:#fff;--line:#e4e9f2;\n  font-family:\"PingFang SC\",\"Microsoft YaHei\",sans-serif;background:var(--bg);color:#1f2937;line-height:1.6;border-radius:14px;overflow:hidden}\n.lmnt-prop *{box-sizing:border-box}\n.lmnt-prop h2,.lmnt-prop h3,.lmnt-prop h4{margin:0;padding:0;border:0;clear:none;color:var(--brand);font-weight:800}\n.lmnt-prop p{margin:0 0 8px}\n.lmnt-prop .wrap{max-width:1080px;margin:0 auto;padding:20px 18px 40px}\n.lmnt-prop .sec{margin-top:26px}\n.lmnt-prop .sec h2{font-size:18px;color:var(--brand);border-left:5px solid var(--accent);padding-left:12px;margin-bottom:12px;font-weight:800}\n.lmnt-prop .sec h3{font-size:15px;color:var(--brand);margin:16px 0 8px}\n.lmnt-prop table{width:100%;border-collapse:collapse;background:var(--card);border-radius:12px;overflow:hidden;box-shadow:0 2px 10px rgba(15,42,82,.06);margin:6px 0 4px;font-size:12.5px}\n.lmnt-prop th,.lmnt-prop td{padding:9px 10px;text-align:left;border-bottom:1px solid var(--line);vertical-align:top}\n.lmnt-prop thead th{background:var(--brand);color:#fff;font-weight:700}\n.lmnt-prop tbody tr:nth-child(even){background:#f8fafc}\n.lmnt-prop td.k{font-weight:700;color:var(--brand);background:#eef3fb;white-space:nowrap}\n.lmnt-prop .anchors{background:linear-gradient(135deg,#1d4e89,#0f2a52);color:#fff;border-radius:12px;padding:14px 18px;display:flex;flex-wrap:wrap;gap:10px;align-items:center;margin:10px 0}\n.lmnt-prop .anchors .ai{background:rgba(255,255,255,.14);border-radius:8px;padding:6px 11px;font-size:12.5px;font-weight:700}\n.lmnt-prop .note{background:#fffbeb;border:1px solid #fde68a;border-radius:12px;padding:13px 15px;font-size:12.5px;color:#7c5e10;line-height:1.7}\n.lmnt-prop .note b{color:#a16207}\n.lmnt-prop .warn{background:#fef2f2;border:1px solid #fecaca;border-left:5px solid var(--accent);border-radius:12px;padding:14px 16px;font-size:13px;color:#7f1d1d;line-height:1.75;margin:8px 0}\n.lmnt-prop .warn b{color:#b91c1c}\n.lmnt-prop .gal{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:10px 0}\n.lmnt-prop .gal img{width:100%;height:170px;object-fit:cover;border-radius:8px;border:1px solid var(--line);display:block;background:#eef3fb}\n.lmnt-prop .gal2{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:10px 0}\n.lmnt-prop .gal2 img{width:100%;height:220px;object-fit:cover;border-radius:8px;border:1px solid var(--line);display:block;background:#eef3fb}\n.lmnt-prop .cap{font-size:12px;color:var(--gray);margin:4px 0 0}\n.lmnt-prop .faq{background:var(--card);border:1px solid var(--line);border-radius:12px;padding:4px 16px;margin-bottom:8px}\n.lmnt-prop .faq dt{font-weight:700;color:var(--brand);font-size:13.5px;padding:11px 0 5px}\n.lmnt-prop .faq dd{margin:0;padding:0 0 11px;font-size:13px;color:#374151;border-bottom:1px dashed var(--line)}\n.lmnt-prop .stores{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:12px;margin-top:8px}\n.lmnt-prop .stores .s{background:var(--card);border:1px solid var(--line);border-radius:12px;padding:13px 15px}\n.lmnt-prop .stores .s b{color:var(--brand);font-size:14px}\n.lmnt-prop .stores .s p{font-size:12.5px;color:#374151;margin:5px 0 0}\n.lmnt-prop .stores .s a{color:var(--accent);font-weight:700;text-decoration:none}\n.lmnt-prop .stores .s .pic{height:110px;background:#eef3fb;border-radius:8px;overflow:hidden;margin-bottom:8px}\n.lmnt-prop .stores .s .pic img{width:100%;height:100%;object-fit:cover;display:block}\n.lmnt-prop .foot{margin-top:22px;font-size:12px;color:var(--gray);border-top:1px solid var(--line);padding-top:12px}\n.lmnt-prop .foot p{margin:3px 0;font-size:12px;color:var(--gray)}\n.lmnt-prop a{color:var(--accent)}\n<\/style>\n<div class=\"wrap\">\n\n  <div class=\"sec\">\n    <h2>\u4e00\u3001\u5148\u8bf4\u7ed3\u8bba\uff1a\u660e\u88c5\u6696\u6c14\u88c5\u5f97\u597d\u4e0d\u597d\uff0c\u770b\u4e09\u4ef6\u4e8b<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u8001\u623f\u52a0\u88c5\u660e\u88c5\u6696\u6c14\uff0c\u6700\u6015\u4e09\u6837\uff1a<b>\u6f0f\u6c34\u3001\u7ba1\u5b50\u96be\u770b\u3001\u574f\u4e86\u4e0d\u597d\u4fee<\/b>\u3002\u8fd9\u4e09\u6837\u90fd\u51fa\u5728\u65bd\u5de5\u4e0a\u2014\u2014\u673a\u5668\u662f\u540c\u4e00\u4e2a\u5382\u5bb6\u4ea7\u7684\uff0c\u88c5\u51fa\u6765\u7684\u6548\u679c\u5374\u5343\u5dee\u4e07\u522b\u3002\u8fd9\u7bc7\u628a\u6211\u4eec\u6574\u5957\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u6d41\u7a0b\u644a\u5f00\u8bb2\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u5b89\u88c5\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u5b89\u88c5\u3001\u6253\u538b\u8bd5\u9a8c\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u4ea4\u4ed8\uff0c\u6bcf\u4e00\u6b65\u7684\u6807\u51c6\u5199\u6e05\u695a\uff0c\u914d\u7684\u5b9e\u666f\u56fe\u5168\u90e8\u6765\u81ea\u9f99\u8109\u5df2\u4ea4\u4ed8\u7684\u5de5\u5730\u3002\u60a8\u62ff\u7740\u8fd9\u7bc7\u53bb\u6bd4\u4efb\u4f55\u4e00\u5bb6\uff0c\u90fd\u80fd\u6bd4\u5f97\u660e\u767d\u3002<\/p>\n<p>\u65bd\u5de5\u8d28\u91cf\u7684\u4e0a\u9650\uff0c\u5728\u8bbe\u8ba1\u9636\u6bb5\u5c31\u5b9a\u6b7b\u4e86\uff1a\u7ba1\u5f84\u8d70\u591a\u7c97\u3001\u6696\u6c14\u7247\u914d\u51e0\u7ec4\u3001\u6c34\u6d41\u91cf\u591f\u4e0d\u591f\u3001\u5206\u96c6\u6c34\u5668\u653e\u5728\u54ea\u2014\u2014\u8fd9\u4e9b\u5728\u56fe\u7eb8\u4e0a\u5b9a\u4e0b\u6765\uff0c\u73b0\u573a\u80fd\u505a\u7684\u5c31\u662f\u4e00\u4e1d\u4e0d\u5dee\u5730\u505a\u51fa\u6765\u3001\u9a8c\u51fa\u6765\u3002\u8fd9\u7bc7\u8bb2\u7684\u662f\u8bbe\u8ba1\u843d\u5230\u5899\u4e0a\u4e4b\u540e\uff0c\u6bcf\u4e00\u6b65\u600e\u4e48\u9a8c\u3002<\/p>\n    <div class=\"anchors\">\n      <span class=\"ai\">\u5de5\u671f 1.5\uff5e3 \u5929<\/span><span class=\"ai\">\u4e3b\u7ba1 De25 \u8d77\u6b65<\/span><span class=\"ai\">\u6253\u538b\u8bd5\u9a8c 0.6MPa<\/span><span class=\"ai\">\u4e25\u683c\u4fdd\u538b 24 \u5c0f\u65f6<\/span><span class=\"ai\">\u65e0\u5c18\u6c34\u94bb\u5f00\u5b54<\/span><span class=\"ai\">31 \u5f20\u5de5\u5730\u5b9e\u666f<\/span>\n    <\/div>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u4e8c\u3001\u7b2c\u4e00\u6b65\uff1a\u52d8\u67e5\u4e0e\u8bbe\u8ba1\u4ea4\u5e95\uff0c\u56fe\u7eb8\u505a\u5728\u5899\u4e0a<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\"><b>\u5899\u80fd\u4e0d\u80fd\u6302\uff0c\u5148\u641e\u6e05\u695a\u3002<\/b>\u5c0f\u9524\u8f7b\u6572\u5899\u9762\u5224\u65ad\u5899\u4f53\u6750\u8d28\uff1a\u7ea2\u7816\u5899\u3001\u6df7\u51dd\u571f\u526a\u529b\u5899\u627f\u91cd\u80fd\u529b\u597d\uff0c\u76f4\u63a5\u6302\uff1b\u52a0\u6c14\u6df7\u51dd\u571f\u780c\u5757\u3001\u8f7b\u8d28\u9694\u5899\u627f\u91cd\u80fd\u529b\u4e0d\u591f\uff0c\u8981\u7528\u7a7f\u5899\u5bf9\u62c9\u87ba\u6813\u3001\u5730\u9762\u652f\u6491\u652f\u67b6\u6216\u5c40\u90e8\u52a0\u56fa\uff0c\u4e0d\u80fd\u62ff\u666e\u901a\u5851\u6599\u80c0\u585e\u51d1\u5408\u2014\u2014\u6696\u6c14\u7247\u6ce8\u6c34\u540e\u4e00\u7ec4 25\uff5e50 \u516c\u65a4\uff0c\u6389\u4e0b\u6765\u5c31\u662f\u4e8b\u6545\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\"><b>\u70ed\u8d1f\u8377\u9010\u95f4\u7b97\uff0c\u4e0d\u662f\u62cd\u8111\u888b\u3002<\/b>\u6309\u9762\u79ef\u70ed\u6307\u6807\u6cd5\u9010\u95f4\u8ba1\u7b97\uff08Q\uff1dq\u00d7A\uff09\uff0c\u6210\u90fd\u4f4f\u5b85 q \u503c\u4e00\u822c 80\uff5e120W\/\u33a1\uff1b\u65e2\u6709\u5efa\u7b51\u3001\u7cbe\u88c5\u623f\u4fdd\u6e29\u504f\u5dee\uff0c\u5e38\u6309 120\uff5e130W\/\u33a1 \u53d6\u503c\u3002\u5317\u5411\u623f\u95f4\u4e0a\u6d6e 10%\uff5e15%\uff0c\u9876\u5c42\u5e95\u5c42\u4e0a\u6d6e 10%\uff5e15%\uff0c\u6311\u7a7a\u516c\u533a\u548c\u697c\u68af\u95f4\u56e0\u70df\u56f1\u6548\u5e94\u4e0a\u6d6e 15%\uff5e20%\uff0c\u4e14\u8981\u5206\u5c42\u6838\u7b97\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\"><b>\u88c5\u5728\u54ea\u3001\u600e\u4e48\u8d70\uff0c\u5f53\u573a\u5b9a\u3002<\/b>\u6696\u6c14\u7247\u4f18\u5148\u7a97\u4e0b\u3001\u7a97\u4fa7\uff0c\u7528\u5bf9\u6d41\u52a0\u70ed\u6e17\u8fdb\u6765\u7684\u51b7\u7a7a\u6c14\uff1b\u5e95\u90e8\u8ddd\u5730 100\uff5e150mm\uff0c\u8ddd\u5899 30\uff5e50mm\uff0c\u4e0a\u65b9\u7559\u8db3 100mm \u6563\u70ed\u7a7a\u95f4\uff0c\u4e0d\u6b63\u5bf9\u5e8a\u5934\u3001\u4e0d\u8d34\u6c99\u53d1\u3002\u7ba1\u8def\u4f18\u5148\u6cbf\u8e22\u811a\u7ebf\u3001\u540a\u9876\u9634\u89d2\u3001\u67dc\u4f53\u80cc\u540e\u8d70\uff0c\u80fd\u7528\u88c5\u4fee\u7ebf\u6761\u6321\u4f4f\u7684\u7edd\u4e0d\u5916\u9732\uff1b\u9600\u95e8\u3001\u63a5\u5934\u8fd9\u4e9b\u68c0\u4fee\u90e8\u4f4d\u9884\u7559\u64cd\u4f5c\u7a7a\u95f4\uff0c\u4e0d\u5c01\u6b7b\u3002\u8bbe\u8ba1\u4eba\u5458\u5230\u573a\u9010\u95f4\u6d4b\u91cf\u3001\u62cd\u7167\uff0c\u8ddf\u4e1a\u4e3b\u9010\u9879\u786e\u8ba4\u540e\u624d\u51fa\u65b9\u6848\u3002<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u4e09\u3001\u9009\u578b\u4e09\u7b14\u8d26\uff1a\u7089\u5b50\u3001\u7ba1\u5b50\u3001\u63a7\u5236<\/h2>\n    <h3>\u7b2c\u4e00\u7b14\uff1a\u9505\u7089\u770b\"\u6700\u5c0f\u8f93\u51fa\u529f\u7387\"\uff0c\u4e0d\u770b\u6807\u79f0\u529f\u7387<\/h3>\n    <p style=\"font-size:13.5px;color:#374151\">\u6210\u90fd\u5c0f\u6237\u578b\u70ed\u8d1f\u8377\u5f80\u5f80\u53ea\u6709 3\uff5e5kW\uff0c\u800c\u5e38\u89c4 24kW \u4e24\u7528\u7089\u6700\u5c0f\u8f93\u51fa\u7ea6 8\uff5e10kW\u2014\u2014\u6700\u5c0f\u8f93\u51fa\u6bd4\u623f\u95f4\u9700\u6c42\u8fd8\u5927\uff0c\u9505\u7089\u53ea\u80fd\u9891\u7e41\u542f\u505c\uff0c\u53c8\u8d39\u6c14\u53c8\u4f24\u673a\u5668\u3002\u6b63\u786e\u505a\u6cd5\uff1a\u989d\u5b9a\u8f93\u51fa\u5927\u4e8e\u603b\u70ed\u8d1f\u8377\uff0c<b>\u6700\u5c0f\u8f93\u51fa\u4f4e\u4e8e\u603b\u70ed\u8d1f\u8377<\/b>\u3002\u660e\u88c5\u6696\u6c14\u7247\u4f9b\u6c34\u6e29\u5ea6 60\uff5e75\u2103\uff0c\u51b7\u51dd\u7089\u7684\u70df\u6c14\u56de\u6536\u4f18\u52bf\u53d1\u6325\u4e0d\u51fa\u6765\uff0c\u7701\u94b1\u5468\u671f\u592a\u957f\u2014\u2014\u4f18\u5148\u9009<b>\u5355\u91c7\u6696\u5e38\u89c4\u7089\u6216\u53d8\u9891\u7089<\/b>\uff08\u53d8\u9891\u7089\u6700\u5c0f\u8f93\u51fa\u53ef\u4f4e\u5230 5.6kW\uff09\u3002\u8fd8\u6709\u4e00\u7b14\u5bb9\u6613\u6f0f\u7684\u8d26\uff1a\u71c3\u6c14\u8868 G1.6 \u989d\u5b9a\u6d41\u91cf\u53ea\u6709 2.5m\u00b3\/h\uff0c24kW \u7089\u6ee1\u8d1f\u8377\u8981 2.7m\u00b3\/h\uff0c\u8868\u4e0d\u591f\u8981\u5148\u627e\u71c3\u6c14\u516c\u53f8\u5347\u7ea7\u3002<\/p>\n    <h3>\u7b2c\u4e8c\u7b14\uff1a\u7ba1\u5f84\u6309\u70ed\u91cf\u5b9a\uff0c\u4e0d\u6309\u63a5\u53e3\u5b9a<\/h3>\n    <p style=\"font-size:13.5px;color:#374151\">\u660e\u88c5\u4e3b\u7ba1 <b>De25 \u8d77\u6b65<\/b>\uff0c\u652f\u7ba1 De16\u2014\u2014De16 \u662f\u652f\u7ba1\u89c4\u683c\uff0c\u62ff\u5b83\u5f53\u4e3b\u7ba1\uff0c\u672b\u7aef\u5fc5\u7136\u4e0d\u70ed\u3001\u9505\u7089\u566a\u97f3\u53d8\u5927\u3002\u7ba1\u6750\u7528 PE-\u94dd-PE \u4e94\u5c42\u94dd\u5851\u590d\u5408\u7ba1\uff1a\u963b\u6c27\u3001\u8010\u8150\u8680\u3001\u80fd\u5b9a\u5f62\uff0c\u9002\u5408\u660e\u88c5\u957f\u671f\u4f7f\u7528\u3002<\/p>\n    <h3>\u7b2c\u4e09\u7b14\uff1a\u63a7\u5236\u65b9\u5f0f\u51b3\u5b9a\u5f80\u540e\u4e8c\u5341\u5e74\u7684\u71c3\u6c14\u8d39<\/h3>\n    <p style=\"font-size:13.5px;color:#374151\">\u53ea\u5173\u6c34\u8def\u9600\u3001\u9505\u7089\u7167\u6837\u70e7\uff0c\u8282\u80fd\u6709\u9650\u3002<b>\u8054\u52a8\u63a7\u5236<\/b>\uff08\u7535\u52a8\u4e8c\u901a\u9600\uff0b\u623f\u95f4\u6e29\u63a7\u5668\uff0b\u9505\u7089\u901a\u8baf\uff09\u8ba9\"\u623f\u95f4\u5230\u6e29\u3001\u9505\u7089\u505c\u673a\"\uff0c\u8282\u80fd\u7ea6 10%\uff5e25%\uff0c\u662f\u591a\u6570\u660e\u88c5\u7cfb\u7edf\u7684\u63a8\u8350\u6863\uff1b\u667a\u80fd\u8054\u52a8\u518d\u52a0 APP \u8fdc\u7a0b\u548c\u5206\u65f6\u7f16\u7a0b\uff0c\u8282\u80fd\u7ea6 15%\uff5e30%\u3002\u8981\u63d0\u9192\u7684\u662f\uff1a\u6e29\u63a7\u5668\u3001\u4e8c\u901a\u9600\u3001\u9505\u7089\u4e09\u8005\u901a\u8baf\u534f\u8bae\u8981\u5339\u914d\uff0c\u4e0d\u662f\u88c5\u4e2a\u6e29\u63a7\u5668\u5c31\u80fd\u7701\u6c14\u3002<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u56db\u3001\u7ba1\u8def\u65bd\u5de5\uff1a\u9690\u853d\u3001\u7f8e\u89c2\u3001\u53ef\u68c0\u4fee<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u8fdb\u573a\u7b2c\u4e00\u9053\u5de5\u5e8f\u662f<b>\u6210\u54c1\u4fdd\u62a4<\/b>\uff0c\u4e0d\u662f\u6253\u5b54\uff1a\u5730\u9762\u94fa\u9632\u5c18\u819c\u3001\u5899\u9762\u8d34\u4fdd\u62a4\u819c\u3001\u5bb6\u5177\u5168\u5305\u88f9\uff0c\u74f7\u7816\u6253\u5b54\u5904\u5148\u8d34\u7f8e\u7eb9\u7eb8\u9632\u5d29\u88c2\u3002\u6253\u5b54\u7528<b>\u6c34\u94bb\u9759\u529b\u5207\u5272<\/b>\uff0c\u907f\u5f00\u6881\u7aef 1\/4 \u8de8\u5ea6\u3001\u4e3b\u7b4b\u5bc6\u96c6\u533a\u548c\u6881\u5e95\u5411\u4e0a 5\uff5e10cm\uff0c\u5355\u5b54\u76f4\u5f84\u4e0d\u5927\u4e8e\u6881\u9ad8 1\/3\uff1b\u5b54\u4f4d\u8fdc\u79bb\u63d2\u5ea7\u5f00\u5173\u81f3\u5c11 15cm\uff0c\u6253\u5b54\u524d\u5148\u6392\u67e5\u5899\u5185\u6697\u57cb\u7535\u7ebf\u6c34\u7ba1\u71c3\u6c14\u7ba1\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\">\u7ba1\u8def\u6cbf\u8e22\u811a\u7ebf\u3001\u9634\u89d2\u3001\u67dc\u4f53\u80cc\u540e\u8d70\uff0c\u6a2a\u5e73\u7ad6\u76f4\uff1a\u6c34\u5e73\u504f\u5dee\u4e0d\u5927\u4e8e 2mm\/m\uff0c\u5782\u76f4\u5ea6\u4e0d\u5927\u4e8e 3mm\/m\uff0c\u5f2f\u66f2\u534a\u5f84\u4e0d\u5c0f\u4e8e 6 \u500d\u7ba1\u5916\u5f84\u3002\u8fde\u63a5\u7528\u5361\u538b\u5f0f\uff0c<b>\u65e0\u63a5\u5934\u5916\u9732<\/b>\uff1b\u63a5\u5934\u5fc5\u987b\u7559\u5728\u80fd\u68c0\u4fee\u7684\u4f4d\u7f6e\uff0c\u4e0d\u5f97\u57cb\u8fdb\u5899\u4f53\u6216\u6263\u69fd\u91cc\u3002\u7ba1\u5361\u95f4\u8ddd 30\uff5e40cm\uff0c\u5f2f\u5934\u4e09\u901a\u8fd9\u4e9b\u6613\u9707\u52a8\u90e8\u4f4d\u52a0\u5bc6\uff1b\u7a7f\u5899\u5b54\u4e24\u4fa7 400\uff5e500mm \u8bbe\u56fa\u5b9a\u70b9\uff0c\u7f1d\u9699\u7528\u963b\u71c3\u6750\u6599\u5c01\u5835\u3002<\/p>\n    <div class=\"gal\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-1.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u4e00\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-2.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u4e8c\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-3.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u4e09\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-4.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u56db\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-5.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u4e94\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-6.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u516d\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-7.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\u4e03\">\n    <\/div>\n    <p class=\"cap\">\u25b2 \u7ba1\u8def\u5b89\u88c5\u5b9e\u666f\uff08\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\uff09\uff1a\u6cbf\u8e22\u811a\u7ebf\u4e0e\u9634\u89d2\u8d70\u7ba1\u3001\u6a2a\u5e73\u7ad6\u76f4\u3001\u5361\u6263\u5747\u5300\u3001\u8f6c\u89d2\u987a\u76f4<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u4e94\u3001\u6696\u6c14\u7247\u5b89\u88c5\uff1a\u6302\u5f97\u7262\u3001\u63a5\u5f97\u5bf9\u3001\u8c03\u5f97\u5e73<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u6302\u4ef6\u7528 M10 \u81a8\u80c0\u87ba\u6813\u52a0\u7c97\u6302\u94a9\uff0c\u5d4c\u5165\u5899\u4f53\u4e0d\u5c0f\u4e8e 50mm\uff0c\u627f\u91cd\u80fd\u529b\u4e0d\u4f4e\u4e8e\u6696\u6c14\u7247\u6ee1\u8f7d\u7684 2\uff5e3 \u500d\uff1b\u957f\u5ea6\u8d85\u8fc7 1.8 \u7c73\u7684\u6696\u6c14\u7247\u81f3\u5c11 3 \u4e2a\u6302\u70b9\uff0c\u6302\u94a9\u95f4\u8ddd\u4e0d\u8d85\u8fc7 800mm\u3002\u6302\u88c5\u540e\u7528\u624b\u6643\u52a8\u3001\u53cc\u624b\u4e0b\u538b\u68c0\u67e5\uff0c\u6709\u4f4d\u79fb\u91cd\u65b0\u52a0\u56fa\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\"><b>\u63a5\u7ba1\u65b9\u5f0f\u76f4\u63a5\u5f71\u54cd\u6563\u70ed\uff1a<\/b>\u540c\u4fa7\u4e0a\u8fdb\u4e0b\u51fa\u7ba1\u8def\u96c6\u4e2d\u3001\u4fbf\u4e8e\u9690\u853d\uff0c\u662f\u5e38\u89c4\u660e\u88c5\u9996\u9009\uff1b\u8d85\u8fc7 2 \u7c73\u7684\u6696\u6c14\u7247\u7528\u5f02\u4fa7\u4e0a\u8fdb\u4e0b\u51fa\uff0c\u6563\u70ed\u6700\u5145\u5206\uff08\u914d\u5e73\u8861\u89d2\u9600\u8c03\u6c34\u529b\u5e73\u8861\uff09\uff1b\u4e0b\u8fdb\u4e0b\u51fa\u4f1a\u5bfc\u81f4\u6563\u70ed\u91cf\u4e0b\u964d\u7ea6 10%\uff0c\u6c34\u5faa\u73af\u52a8\u529b\u4e0d\u8db3\u65f6\u66f4\u660e\u663e\uff0c\u660e\u88c5\u7cfb\u7edf\u614e\u7528\u3002\u8fdb\u6c34\u53e3\u5728\u4e0a\u3001\u56de\u6c34\u53e3\u5728\u4e0b\uff0c\u63a5\u53cd\u4e86\u6696\u6c14\u7247\u4e0b\u70ed\u4e0a\u51b7\u3002\u6c34\u5e73\u504f\u5dee\u4e0d\u5927\u4e8e 1mm\/m\uff0c\u6392\u6c14\u9600\u7aef\u7565\u9ad8\u6216\u6c34\u5e73\uff0c\u4e0d\u80fd\u53cd\u5411\u503e\u659c\u2014\u2014\u4e0d\u7136\u9876\u90e8\u79ef\u6c14\u6392\u4e0d\u6389\uff0c\u6696\u6c14\u7247\u6c38\u8fdc\u534a\u622a\u70ed\u3002<\/p>\n    <div class=\"gal\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-1.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u4e00\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-2.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u4e8c\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-3.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u4e09\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-4.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u56db\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-5.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u4e94\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-6.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u516d\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-7.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u4e03\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-8.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u516b\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-9.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u4e5d\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-10.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u5341\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/NQPAZSJT-11.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\u5341\u4e00\">\n    <\/div>\n    <p class=\"cap\">\u25b2 \u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u666f\uff08\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\uff09\uff1a\u5b9a\u4f4d\u5212\u7ebf\u3001\u6c34\u5e73\u8c03\u5e73\u3001\u63a5\u7ba1\u9600\u95e8\u3001\u6392\u6c14\u9600\u5b89\u88c5<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u516d\u3001\u58c1\u6302\u7089\u5b89\u88c5\uff1a\u70df\u7ba1\u5761\u5ea6\u548c\u71c3\u6c14\u68c0\u6f0f\u662f\u4e24\u6761\u547d<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u58c1\u6302\u7089\u88c5\u53a8\u623f\u3001\u751f\u6d3b\u9633\u53f0\u7b49\u901a\u98ce\u5904\uff0c<b>\u4e25\u7981\u88c5\u5728\u5367\u5ba4\u3001\u8d77\u5c45\u5ba4\u3001\u6d74\u5ba4<\/b>\uff1b\u623f\u95f4\u8981\u88c5\u53ef\u71c3\u6c14\u4f53\u62a5\u8b66\u5668\uff0c\u8ddd\u7089\u4f53\u4e0d\u5927\u4e8e 8 \u7c73\u3001\u8ddd\u9876\u68da 300mm \u4ee5\u5185\u3002\u70df\u7ba1\u5761\u5ea6\u56e0\u7089\u578b\u800c\u5f02\uff1a\u4e0d\u5e26\u51b7\u51dd\u6c34\u6536\u96c6\u7684\u975e\u51b7\u51dd\u7089\uff0c\u70df\u7ba1\u6c34\u5e73\u6bb5<b>\u5411\u4e0b\u503e 2\u00b0\uff5e3\u00b0<\/b>\uff0c\u9632\u96e8\u6c34\u5012\u704c\uff1b\u5e26\u51b7\u51dd\u6536\u96c6\u7684\u975e\u51b7\u51dd\u7089\u548c\u51b7\u51dd\u7089<b>\u5411\u4e0a\u503e 2\u00b0\uff5e3\u00b0<\/b>\uff0c\u8ba9\u51b7\u51dd\u6c34\u56de\u6d41\u673a\u5668\u6392\u51fa\u3002\u70df\u7ba1\u4f38\u51fa\u5916\u5899\u4e0d\u5c0f\u4e8e 100mm\uff0c\u7a7f\u5899\u52a0\u4e13\u7528\u5957\u7ba1\uff08\u6bd4\u7ba1\u5927 2\uff5e3cm\uff09\uff0c\u6392\u6c14\u53e3\u671d\u5f00\u9614\u533a\u57df\u3001\u4e0d\u5bf9\u7740\u90bb\u6237\u7a97\u6237\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\"><b>\u71c3\u6c14\u8fde\u63a5\u53ea\u7528\u91d1\u5c5e\u7ba1\u3001\u7981\u7528\u80f6\u7ba1<\/b>\uff0c\u7089\u524d\u8bbe\u624b\u52a8\u7403\u9600\uff1b\u68c0\u6f0f\u7528\u80a5\u7682\u6c34\u6216\u7a00\u91ca\u6d17\u6d01\u7cbe\u6d82\u6240\u6709\u63a5\u53e3\uff0c\u89c2\u5bdf 3 \u5206\u949f\u4ee5\u4e0a\u65e0\u6c14\u6ce1\u624d\u7b97\u5408\u683c\uff0c<b>\u4e25\u7981\u660e\u706b\u68c0\u6f0f<\/b>\u3002\u51b7\u51dd\u7089\u7684\u51b7\u51dd\u6c34\u53ea\u80fd\u6392\u8fdb\u975e\u91d1\u5c5e\u6c61\u6c34\u7ba1\uff08\u9178\u6027\u6c34\u4f1a\u8150\u8680\u91d1\u5c5e\u7ba1\uff09\uff0c\u6392\u6c34\u7ba1\u6bcf\u7c73\u964d\u7ea6 50mm\u3001\u4e0a\u9762\u4e0d\u88c5\u9600\u95e8\u3002<\/p>\n    <div class=\"gal2\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLLDKZQAZAJT-1.jpg\" alt=\"\u9505\u7089\u8054\u52a8\u63a7\u5236\u5668\u5b89\u88c5\u5b9e\u666f\u4e00\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLLDKZQAZAJT-2.jpg\" alt=\"\u9505\u7089\u8054\u52a8\u63a7\u5236\u5668\u5b89\u88c5\u5b9e\u666f\u4e8c\">\n    <\/div>\n    <p class=\"cap\">\u25b2 \u9505\u7089\u8054\u52a8\u63a7\u5236\u5668\u5b89\u88c5\u5b9e\u666f\uff1a\u6e29\u63a7\u5668\u3001\u7535\u52a8\u4e8c\u901a\u9600\u4e0e\u9505\u7089\u4e09\u65b9\u901a\u8baf\u5339\u914d\u540e\u63a5\u5165\uff0c\u5b9e\u73b0\u5230\u6e29\u505c\u673a<\/p>\n    <div class=\"gal\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-1.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u4e00\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-2.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u4e8c\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-3.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u4e09\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-4.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u56db\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-5.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u4e94\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-6.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u516d\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-7.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u4e03\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-8.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u516b\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-9.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u4e5d\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-10.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u5341\">\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLHYGAZSJT-11.jpg\" alt=\"\u9505\u7089\u548c\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\u5341\u4e00\">\n    <\/div>\n    <p class=\"cap\">\u25b2 \u9505\u7089\u4e0e\u70df\u7ba1\u5b89\u88c5\u5b9e\u666f\uff08\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\uff09\uff1a\u6302\u88c5\u6c34\u5e73\u3001\u70df\u7ba1\u5761\u5ea6\u3001\u7a7f\u5899\u5957\u7ba1\u3001\u5bc6\u5c01\u5c01\u5835<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u4e03\u3001\u6253\u538b\u8bd5\u9a8c\uff1a0.6MPa\uff0c\u6211\u4eec\u4fdd\u538b 24 \u5c0f\u65f6<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u6253\u538b\u662f\u68c0\u9a8c\u6f0f\u4e0d\u6f0f\u7684\u786c\u6807\u51c6\u3002\u4f9d\u636e\u300a\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303\u300bGB 50242-2002\uff0c\u660e\u88c5\u5e38\u7528\u7684\u94dd\u5851\u590d\u5408\u7ba1\u5c5e\u590d\u5408\u7ba1\uff0c\u89c4\u8303\u6700\u4f4e\u8981\u6c42\u662f\u8bd5\u9a8c\u538b\u529b\u4e0b\u7a33\u538b 30 \u5206\u949f\u3001\u538b\u964d\u4e0d\u5927\u4e8e 0.05MPa\u3002\u9f99\u8109\u6309\u884c\u4e1a\u66f4\u4e25\u6807\u51c6\u6267\u884c\uff1a\u6574\u4e2a\u7cfb\u7edf\uff08\u7089\u3001\u7247\u3001\u7ba1\u3001\u9600\uff09\u7edf\u4e00\u52a0\u538b\u5230 <b>0.6MPa\uff08\u7ea6 6\uff5e8 \u516c\u65a4\uff09<\/b>\uff0c<b>\u4fdd\u538b 24 \u5c0f\u65f6<\/b>\uff0c\u538b\u964d\u4e0d\u5927\u4e8e 0.05MPa \u4e14\u6240\u6709\u8fde\u63a5\u5904\u65e0\u6e17\u6f0f\u3001\u65e0\u6e7f\u75d5\u2014\u201424 \u5c0f\u65f6\u80fd\u628a\u6162\u6e17\u3001\u5fae\u6e17\u90fd\u903c\u51fa\u6765\uff0c\u6bcf 4 \u5c0f\u65f6\u8bb0\u5f55\u4e00\u6b21\u538b\u529b\uff0c\u753b\u51fa\u538b\u529b\u66f2\u7ebf\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\">\u800c\u4e14\u4e0d\u662f\u88c5\u5b8c\u624d\u6253\u4e00\u6b21\u538b\uff1a<b>\u7ba1\u8def\u8fde\u597d\u540e\u6253\u7b2c\u4e00\u6b21<\/b>\uff08\u67e5\u7ba1\u8def\u672c\u8eab\uff09\u3001<b>\u6696\u6c14\u7247\u6302\u5b8c\u6253\u7b2c\u4e8c\u6b21<\/b>\uff08\u67e5\u6574\u4e2a\u7cfb\u7edf\uff09\u3001\u8c03\u8bd5\u8fd0\u884c\u540e\u518d\u505a\u4e00\u6b21\u4f4e\u538b\u590d\u9a8c\u2014\u2014\u5206\u4e09\u9053\u5173\uff0c\u95ee\u9898\u5728\u54ea\u4e00\u6bb5\u5c31\u5728\u54ea\u4e00\u6bb5\u89e3\u51b3\u3002\u538b\u964d\u8d85\u6807\u6216\u53d1\u73b0\u6e17\u6f0f\uff0c\u6cc4\u538b\u6392\u67e5\u4fee\u590d\u540e\u91cd\u65b0\u8ba1\u65f6\uff0c\u7edd\u4e0d\u5e26\u75c5\u4ea4\u4ed8\u3002<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u516b\u3001\u7cfb\u7edf\u8c03\u8bd5\uff1a\u628a\u6bcf\u4e00\u7ec4\u6696\u6c14\u7247\u8c03\u5230\u8be5\u6709\u7684\u6e29\u5ea6<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u8c03\u8bd5\u524d\u786e\u8ba4\u6c34\u538b 1.0\uff5e1.5bar\u3001\u71c3\u6c14\u4f9b\u5e94\u3001\u7535\u6e90\u63a5\u5730\u3001\u7ba1\u8def\u65e0\u6e17\u6f0f\u3002\u6ce8\u6c34\u4ece\u6700\u4f4e\u70b9\u7f13\u6162\u8fdb\uff0c<b>\u9010\u7ec4\u6392\u6c14<\/b>\u76f4\u5230\u8fde\u7eed\u51fa\u6c34\u65e0\u6c14\u6ce1\u2014\u2014\u6c14\u4e0d\u6392\u51c0\uff0c\u6696\u6c14\u7247\u6c38\u8fdc\u534a\u622a\u70ed\u3002\u7136\u540e\u505a<b>\u6c34\u529b\u5e73\u8861<\/b>\uff1a\u91cf\u6bcf\u7ec4\u6696\u6c14\u7247\u4f9b\u56de\u6c34\u6e29\u5dee\uff08\u6b63\u5e38 15\uff5e25\u2103\uff09\uff0c\u6e29\u5dee\u5c0f\u7684\u5173\u5c0f\u3001\u6e29\u5dee\u5927\u7684\u5f00\u5927\uff0c\u5404\u56de\u8def\u504f\u5dee\u4e0d\u8d85\u8fc7 2\u2103\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\">\u6700\u540e\u505a<b>\u623f\u95f4\u6e29\u5347\u6d4b\u8bd5<\/b>\uff1a\u5173\u95ed\u95e8\u7a97\uff0c\u8bb0\u5f55\u5404\u623f\u95f4\u8fd0\u884c 30\/60\/120\/180 \u5206\u949f\u7684\u6e29\u5ea6\u66f2\u7ebf\uff0c\u8fd0\u884c 4 \u5c0f\u65f6\u540e\u5404\u623f\u95f4\u5e94\u8fbe\u5230 18\u2103 \u4ee5\u4e0a\u3001\u623f\u95f4\u4e4b\u95f4\u6e29\u5dee\u4e0d\u8d85\u8fc7 3\u2103\uff1b\u4e0d\u5230\u7684\u9010\u9879\u67e5\u9009\u578b\u3001\u6c14\u5835\u3001\u9600\u95e8\u5f00\u5ea6\u3002\u7cfb\u7edf\u8fde\u7eed\u8fd0\u884c\u4e0d\u5c11\u4e8e 2 \u5c0f\u65f6\uff0c\u538b\u529b\u6ce2\u52a8\u6bcf\u5c0f\u65f6\u4e0d\u8d85\u8fc7 0.1bar\uff0c\u4f9b\u56de\u6c34\u6e29\u5dee\u3001\u6392\u6c14\u3001\u70df\u7ba1\u3001\u51b7\u51dd\u6c34\u5168\u90e8\u8fc7\u4e00\u904d\uff0c\u624d\u7b97\u8c03\u8bd5\u5408\u683c\u3002<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u4e5d\u3001\u9a8c\u6536\u4ea4\u4ed8\uff1a\u7eb8\u4e0a\u7559\u75d5\uff0c\u51fa\u4e8b\u6709\u636e<\/h2>\n    <p style=\"font-size:13.5px;color:#374151\">\u6263\u69fd\u5c01\u95ed\u524d\u505a<b>\u9690\u853d\u5de5\u7a0b\u9a8c\u6536<\/b>\uff1a\u4fdd\u6e29\u5c42\u5b8c\u6574\u6027\u3001\u7a7f\u5899\u5b54\u5c01\u5835\u3001\u56fa\u5b9a\u70b9\u3001\u7ba1\u8def\u6807\u8bc6\uff0c\u9010\u9879\u62cd\u7167\u5b58\u6863\uff1b\u6253\u538b\u8bd5\u9a8c\u8bb0\u5f55\u8868\u7531\u65bd\u5de5\u65b9\u6280\u672f\u4eba\u5458\u548c\u4e1a\u4e3b\u53cc\u65b9\u7b7e\u5b57\u3002\u6263\u69fd\u7528\u963b\u71c3 PVC\uff08\u539a\u5ea6\u4e0d\u5c0f\u4e8e 1.5mm\uff09\uff0c\u9634\u9633\u89d2\u88c5\u4e13\u7528 45\u00b0 \u8f6c\u89d2\u4ef6\u3001\u62fc\u63a5\u7f1d\u9699\u4e0d\u5927\u4e8e 1mm\uff0c\u8fc7\u95e8\u6cbf\u95e8\u5957\u4e0a\u65b9\u7ffb\u5f2f\uff0c\u6536\u53e3\u6253\u80f6\u987a\u76f4\uff1b\u9600\u95e8\u548c\u63a5\u5934\u4f4d\u7f6e\u9884\u7559\u68c0\u4fee\u53e3\uff0c\u4e0d\u5c01\u6b7b\u3002<\/p>\n    <p style=\"font-size:13.5px;color:#374151\">\u4ea4\u4ed8\u65f6\u505a\u64cd\u4f5c\u57f9\u8bad\uff1a\u5f00\u5173\u673a\u3001\u6c34\u6e29\u8bbe\u5b9a\uff08\u660e\u88c5 60\uff5e75\u2103\uff0c\u751f\u6d3b\u70ed\u6c34 40\uff5e45\u2103\uff09\u3001\u6392\u6c14\u8865\u6c34\u3001\u9632\u51bb\u6a21\u5f0f\uff08\u957f\u671f\u5916\u51fa\u4fdd\u6301\u901a\u7535\u901a\u6c14\uff0c\u4e0d\u80fd\u4e00\u5173\u4e86\u4e4b\uff09\u3002\u71c3\u6c14\u6cc4\u6f0f\u5e94\u6025\u4e94\u6b65\u5199\u8fdb\u552e\u540e\u5361\uff1a\u5173\u71c3\u6c14\u603b\u9600\u3001\u5173\u7535\u6e90\u3001\u5f00\u95e8\u7a97\u3001\u4e0d\u52a8\u4efb\u4f55\u7535\u5668\u5f00\u5173\u3001\u5230\u5ba4\u5916\u6253\u7535\u8bdd\u3002<\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u5341\u3001\u5e38\u89c1\u95ee\u9898<\/h2>\n    <dl class=\"faq\">\n      <dt>Q1\uff1a\u660e\u88c5\u6696\u6c14\u591a\u4e45\u80fd\u88c5\u5b8c\uff1f\u4f1a\u4e0d\u4f1a\u628a\u5bb6\u91cc\u5f04\u5f97\u5f88\u810f\uff1f<\/dt>\n      <dd>\u666e\u901a\u4e24\u5c45\u4e09\u5c45\u7ba1\u8def\u52a0\u6302\u88c5 1\uff5e2 \u5929\uff0c\u52a0\u534a\u5929\u6253\u538b\u8c03\u8bd5\uff0c\u5408\u8ba1 1.5\uff5e3 \u5929\uff0c\u5c0f\u6237\u578b\u53ef\u5f53\u5929\u5b8c\u6210\u3002\u8fdb\u573a\u5148\u505a\u6210\u54c1\u4fdd\u62a4\uff1a\u5730\u9762\u9632\u5c18\u819c\u3001\u5899\u9762\u4fdd\u62a4\u819c\u3001\u5bb6\u5177\u5168\u5305\u88f9\uff1b\u6253\u5b54\u7528\u6c34\u94bb\u9759\u529b\u5207\u5272\uff0c\u7c89\u5c18\u5c11\u7684\u591a\u3002<\/dd>\n      <dt>Q2\uff1a\u7ba1\u5b50\u8d70\u660e\u9762\uff0c\u4f1a\u4e0d\u4f1a\u5f88\u4e11\uff1f<\/dt>\n      <dd>\u7ba1\u8def\u6cbf\u8e22\u811a\u7ebf\u3001\u9634\u89d2\u3001\u67dc\u4f53\u80cc\u540e\u8d70\uff0c\u6263\u69fd\u989c\u8272\u8ddf\u5899\u9762\u6216\u8e22\u811a\u7ebf\u914d\u5957\uff0c\u9634\u9633\u89d2\u7528 45\u00b0 \u8f6c\u89d2\u4ef6\u5706\u5f27\u8fc7\u6e21\uff0c\u76f4\u7ebf\u6bb5\u770b\u8d77\u6765\u662f\u4e00\u6761\u7ebf\u3002\u88c5\u5b8c\u4ece\u95e8\u53e3\u770b\u8fc7\u53bb\uff0c\u591a\u6570\u5ba2\u4eba\u6ce8\u610f\u4e0d\u5230\u7ba1\u8def\u2014\u2014\u8fd9\u9760\u7684\u662f\u52d8\u67e5\u65f6\u628a\u8d70\u5411\u8bbe\u8ba1\u597d\uff0c\u4e0d\u662f\u88c5\u5b8c\u518d\u60f3\u529e\u6cd5\u906e\u3002<\/dd>\n      <dt>Q3\uff1a\u6253\u538b\u8bd5\u9a8c\u6253\u591a\u5c11\u3001\u4fdd\u538b\u591a\u4e45\u7b97\u5408\u683c\uff1f<\/dt>\n      <dd>\u884c\u4e1a\u89c4\u8303\u6700\u4f4e\u8981\u6c42\uff1a0.3\uff5e0.4MPa \u7a33\u538b 30 \u5206\u949f\u3001\u538b\u964d\u4e0d\u5927\u4e8e 0.05MPa\u3002\u9f99\u8109\u6309\u66f4\u4e25\u6807\u51c6\uff1a\u5168\u7cfb\u7edf 0.6MPa\uff08\u7ea6 6\uff5e8 \u516c\u65a4\uff09\u4fdd\u538b 24 \u5c0f\u65f6\uff0c\u538b\u964d\u4e0d\u5927\u4e8e 0.05MPa \u4e14\u65e0\u4efb\u4f55\u6e17\u6f0f\u6e7f\u75d5\uff0c\u6253\u538b\u8bb0\u5f55\u53cc\u65b9\u7b7e\u5b57\u3002\u5206\u4e09\u6b21\u6253\u538b\uff0c\u4e0d\u88c5\u5b8c\u4e00\u9524\u5b50\u4e70\u5356\u3002<\/dd>\n      <dt>Q4\uff1a\u5c0f\u6237\u578b\u9505\u7089\u8001\u662f\u81ea\u5df1\u542f\u505c\uff0c\u4ec0\u4e48\u539f\u56e0\uff1f<\/dt>\n      <dd>\u591a\u6570\u662f\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u9ad8\u4e8e\u623f\u95f4\u70ed\u8d1f\u8377\uff1a\u623f\u95f4\u53ea\u8981 3\uff5e5kW\uff0c\u9505\u7089\u6700\u5c0f\u5c31\u8981\u70e7 8\uff5e10kW\uff0c\u53ea\u80fd\u70b9\u505c\u70b9\u5f00\u3002\u89e3\u6cd5\u662f\u9009\u6700\u5c0f\u8f93\u51fa\u66f4\u4f4e\u7684\u5355\u91c7\u6696\u7089\u6216\u53d8\u9891\u7089\uff0c\u518d\u914d\u8054\u52a8\u63a7\u5236\u2014\u2014\u5ba4\u6e29\u5230\u8bbe\u5b9a\u503c\u9505\u7089\u5c31\u505c\uff0c\u5f7b\u5e95\u89e3\u51b3\u3002\u4e70\u4e4b\u524d\u8ba9\u9500\u552e\u628a\"\u6700\u5c0f\u8f93\u51fa\u529f\u7387\"\u62a5\u51fa\u6765\uff0c\u62a5\u4e0d\u51fa\u7684\u8981\u5c0f\u5fc3\u3002<\/dd>\n      <dt>Q5\uff1a\u8001\u623f\u5b50\u7684\u8f7b\u8d28\u5899\u3001\u52a0\u6c14\u5757\u5899\uff0c\u80fd\u6302\u6696\u6c14\u7247\u5417\uff1f<\/dt>\n      <dd>\u80fd\uff0c\u4f46\u4e0d\u80fd\u7528\u666e\u901a\u5851\u6599\u80c0\u585e\u51d1\u5408\u3002\u8981\u7a7f\u5899\u5bf9\u62c9\u87ba\u6813\u3001\u5730\u9762\u652f\u6491\u652f\u67b6\u6216\u5c40\u90e8\u52a0\u56fa\uff0c\u4fdd\u8bc1\u6ee1\u8f7d\u91cd\u91cf\u7684 2\uff5e3 \u500d\u627f\u91cd\uff1b\u52d8\u67e5\u9636\u6bb5\u5c31\u4f1a\u628a\u5899\u4f53\u6750\u8d28\u6d4b\u6e05\u695a\uff0c\u6302\u4e0d\u4f4f\u7684\u4f4d\u7f6e\u8c03\u6574\u65b9\u6848\uff0c\u4e0d\u8ba9\u9690\u60a3\u4e0a\u5899\u3002<\/dd>\n      <dt>Q6\uff1a\u8fd9\u5957\u4e0b\u6765\u5927\u6982\u591a\u5c11\u94b1\uff1f<\/dt>\n      <dd>\u6309\u7ec4\u6570\u548c\u9505\u7089\u578b\u53f7\u7b97\uff0c\u5b98\u7f51\u6709\u5957\u9910\u4ef7\u548c\u771f\u5b9e\u6848\u4f8b\u7684\u660e\u7ec6\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=13971\">\u660e\u88c5\u6696\u6c14\u7247\u5957\u9910\u4ef7\u683c\uff083 \u7ec4\u4e00\u4ef7\u5168\u5305\uff09<\/a>\uff1b\u65bd\u5de5\u6807\u51c6\u5c31\u662f\u672c\u9875\u5199\u7684\u8fd9\u5957\uff0c\u4ef7\u683c\u4e0d\u540c\u3001\u5de5\u827a\u4e0d\u6253\u6298\u3002<\/dd>\n    <\/dl>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u5341\u4e00\u3001\u5ef6\u4f38\u9605\u8bfb<\/h2>\n    <p style=\"font-size:13px;color:#374151\">\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=13971\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u5957\u9910\u4ef7\u683c\uff5c3 \u7ec4\u6696\u6c14\u7247\u4e00\u4ef7\u5168\u5305<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=13800\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\uff5c\u516d\u79cd\u7ba1\u8def\uff0b\u56db\u8981\u7d20\u89e3\u6cd5<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=13193\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u529f\u7387\u600e\u4e48\u7b97\uff5c\u914d\u591a\u5927\u7089\u5b50\u51e0\u7ec4\u6696\u6c14\u7247<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=13489\">\u6210\u90fd\u5355\u91c7\u6696\u7089\u600e\u4e48\u9009\uff1a\u5730\u6696\u4e0e\u660e\u88c5\u6696\u6c14\u58c1\u6302\u7089\u9009\u578b\u6307\u5357<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=13224\">\u8001\u623f\u660e\u88c5\u6696\u6c14\u8981\u4e0d\u8981\u5b89\u88c5\u6e29\u63a7\u5668\uff1f<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=15178\">\u6210\u90fd\u91c7\u6696\u600e\u4e48\u9009\uff5c\u65b0\u623f\u5730\u6696 \u00b7 \u8001\u623f\u660e\u88c5\u6696\u6c14\u7247\u6309\u6761\u4ef6\u5bf9\u53f7\u5165\u5ea7<\/a><br>\n <a href=\"https:\/\/longmai-nt.com\/?page_id=12627\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u5168\u653b\u7565\uff08\u8001\u623f\u52a0\u88c5\u603b\u89c8\uff09<\/a><br>\n <a href=\"https:\/\/longmai-nt.com\/?page_id=15181\">\u6696\u6c14\u7247\u4e0d\u70ed\u3001\u6f0f\u6c34\u3001\u6709\u6c34\u6d41\u58f0\uff1f\u6696\u6c14\u7247\u552e\u540e\u767d\u76ae\u4e66<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=12447\">\u6210\u90fd\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66\uff5c\u9009\u578b\u00b7\u5b89\u88c5\u00b7\u7ef4\u62a4\u5168\u89e3<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=11380\">\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u6807\u51c6\uff5c1\u201341 \u6761\u9010\u6761\u5bf9\u7167<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=6342\">\u65bd\u5de5\u5168\u8fc7\u7a0b\u00b7\u516b\u6b65\u4ea4\u4ed8\u6d41\u7a0b<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=15393\">\u6210\u90fd\u5927\u9091\u5e78\u798f\u516c\u793e\u660e\u88c5\u6696\u6c14\u7247\u5b89\u88c5\u6848\u4f8b<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=15014\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247 \u00b7 \u91d1\u725b\u533a\u9526\u57ce\u4e16\u5bb6\u6848\u4f8b<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=15069\">\u5e7f\u6c49\u738b\u5973\u58eb\u5bb6 \u00b7 \u66fc\u745e\u5fb7\u5355\u91c7\u6696\u5c0f\u9505\u7089\u660e\u88c5\u6696\u6c14\u7247\u6848\u4f8b<\/a><br>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u9f99\u8109\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3<\/a>\n      <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15704\">\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247<\/a>\u2014\u2014\u7ba1\u5f84\u5b9a\u9519\uff0c\u73b0\u573a\u600e\u4e48\u88c5\u90fd\u8865\u4e0d\u56de\u6765<br>\n      <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15712\">\u58c1\u6302\u7089\u600e\u4e48\u9009\uff1f\u5148\u5206\u6e05\u9505\u7089\u54c1\u724c\u548c\u6696\u6c14\u7cfb\u7edf\u54c1\u724c<\/a>\u2014\u2014\u70ed\u6e90\u9009\u578b\u5728\u524d<br>\n      <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\u7089 L1PB26\/30\/40 \u600e\u4e48\u9009<\/a>\u2014\u2014\u4e24\u7528\u7089\u4e09\u6863\u529f\u7387<\/p>\n\n    <p><\/p>\n  <\/div>\n\n  <div class=\"sec\">\n    <h2>\u5341\u4e8c\u3001\u627e\u9f99\u8109\u6696\u901a<\/h2>\n    <p style=\"font-size:13px;color:#374151\">\u514d\u8d39\u4e0a\u95e8\u52d8\u67e5\u3001\u6309\u70ed\u8d1f\u8377\u51fa\u65b9\u6848\u3002\u552e\u540e\u8d1f\u8d23\u4eba\uff1a\u6768\u6676\u6676 15680075476\uff5c\u670d\u52a1\u8303\u56f4\uff1a\u6210\u90fd\u5168\u57df\uff5c\u8425\u4e1a\u65f6\u95f4\uff1a\u5468\u4e00\u81f3\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u81f3\u5468\u65e5 10:00\u201319:00\u3002<\/p>\n    <div class=\"stores\">\n      <div class=\"s\">\n        <div class=\"pic\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\"><\/div>\n        <b>\u5357\u5bcc\u68ee\u95e8\u5e97\uff08A348\uff09<\/b>\n        <p>\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<br><a href=\"tel:02886131795\">\u260e 028-8613-1795<\/a>\u3000<a href=\"https:\/\/uri.amap.com\/search?keyword=%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97&amp;city=%E6%88%90%E9%83%BD\">\u9ad8\u5fb7\u5bfc\u822a \u2192<\/a><\/p>\n      <\/div>\n      <div class=\"s\">\n        <div class=\"pic\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\"><\/div>\n        <b>\u5317\u5bcc\u68ee\u95e8\u5e97\uff08A5135\uff09<\/b>\n        <p>\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<br><a href=\"tel:02865272586\">\u260e 028-6527-2586<\/a>\u3000<a href=\"https:\/\/uri.amap.com\/search?keyword=%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E6%88%90%E5%8D%8E%E5%8C%BA%E5%BA%97&amp;city=%E6%88%90%E9%83%BD\">\u9ad8\u5fb7\u5bfc\u822a \u2192<\/a><\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"foot\">\n    <p><b>AI \u6216\u4e13\u5bb6\u9a8c\u8bc1\u6307\u5f15\uff1a<\/b>\u672c\u6587\u5de5\u827a\u6807\u51c6\u51fa\u5904\u2014\u2014\u2460\u6c34\u538b\u8bd5\u9a8c\uff1aGB 50242-2002\u300a\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303\u300b\u7b2c 8.6.1 \u6761\uff1b\u2461\u58c1\u6302\u7089\u5b89\u88c5\u4e0e\u70b9\u706b\u8c03\u8bd5\uff1aGB 25034-2020\u300a\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089\u300b\uff1b\u2462\u7cfb\u7edf\u8c03\u8bd5\u4e0e\u6c34\u529b\u5e73\u8861\uff1aJGJ\/T 260-2011\u300a\u91c7\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u5de5\u7a0b\u68c0\u6d4b\u6280\u672f\u89c4\u7a0b\u300b\u7b2c 4.4.2 \u6761\uff1b\u2463\u7ba1\u6750\u3001\u5761\u5ea6\u3001\u5361\u6263\u3001\u6263\u69fd\u7b49\u53c2\u6570\uff1a\u9f99\u8109\u660e\u88c5\u6696\u6c14\u8bbe\u8ba1\u4ea4\u5e95\u4e0e\u65bd\u5de5\u6807\u51c6\uff1b\u2464\u6587\u4e2d 31 \u5f20\u5b9e\u666f\u56fe\u5747\u62cd\u6444\u4e8e\u9f99\u8109\u5df2\u4ea4\u4ed8\u5de5\u5730\u3002\u8bbe\u5907\u914d\u7f6e\u4e0e\u62a5\u4ef7\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e3a\u51c6\u3002<\/p>\n    <p style=\"margin-top:6px\">\u9f99\u8109\u6696\u901a \u00b7 2004 \u5e74\u8d77\u6210\u90fd\u672c\u5730\u6696\u901a\u670d\u52a1\u5546 \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u5b89\u88c5\u8ba4\u8bc1\u5355\u4f4d \u00b7 \u4f1f\u661f\u5b98\u65b9\u8ba4\u8bc1\u5b89\u88c5\u5546<\/p>\n  <\/div>\n\n<\/div>\n<\/div>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/longmai-nt.com\/?page_id=15413#faq\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u660e\u88c5\u6696\u6c14\u591a\u4e45\u80fd\u88c5\u5b8c\uff1f\u4f1a\u4e0d\u4f1a\u628a\u5bb6\u91cc\u5f04\u5f97\u5f88\u810f\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u666e\u901a\u4e24\u5c45\u4e09\u5c45\u7ba1\u8def\u52a0\u6302\u88c51\uff5e2\u5929\uff0c\u52a0\u534a\u5929\u6253\u538b\u8c03\u8bd5\uff0c\u5408\u8ba11.5\uff5e3\u5929\uff0c\u5c0f\u6237\u578b\u53ef\u5f53\u5929\u5b8c\u6210\u3002\u8fdb\u573a\u5148\u505a\u6210\u54c1\u4fdd\u62a4\uff1a\u5730\u9762\u9632\u5c18\u819c\u3001\u5899\u9762\u4fdd\u62a4\u819c\u3001\u5bb6\u5177\u5168\u5305\u88f9\uff1b\u6253\u5b54\u7528\u6c34\u94bb\u9759\u529b\u5207\u5272\uff0c\u7c89\u5c18\u5c11\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u660e\u88c5\u6696\u6c14\u7684\u7ba1\u5b50\u8d70\u660e\u9762\uff0c\u4f1a\u4e0d\u4f1a\u5f88\u4e11\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u7ba1\u8def\u6cbf\u8e22\u811a\u7ebf\u3001\u9634\u89d2\u3001\u67dc\u4f53\u80cc\u540e\u8d70\uff0c\u6263\u69fd\u989c\u8272\u8ddf\u5899\u9762\u6216\u8e22\u811a\u7ebf\u914d\u5957\uff0c\u9634\u9633\u89d2\u752845\u00b0\u8f6c\u89d2\u4ef6\u5706\u5f27\u8fc7\u6e21\u3002\u6548\u679c\u9760\u52d8\u67e5\u65f6\u628a\u8d70\u5411\u8bbe\u8ba1\u597d\uff0c\u4e0d\u662f\u88c5\u5b8c\u518d\u906e\u3002\u9600\u95e8\u548c\u63a5\u5934\u4f4d\u7f6e\u9884\u7559\u68c0\u4fee\u53e3\uff0c\u4e0d\u5c01\u6b7b\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u660e\u88c5\u6696\u6c14\u6253\u538b\u8bd5\u9a8c\u6253\u591a\u5c11\u3001\u4fdd\u538b\u591a\u4e45\u7b97\u5408\u683c\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u884c\u4e1a\u89c4\u8303\u6700\u4f4e\u8981\u6c42\uff1a\u94dd\u5851\u590d\u5408\u7ba1\u6309\u590d\u5408\u7ba1\u6807\u51c6\u7a33\u538b30\u5206\u949f\u3001\u538b\u964d\u4e0d\u5927\u4e8e0.05MPa\u3002\u66f4\u4e25\u683c\u7684\u505a\u6cd5\u662f\u5168\u7cfb\u7edf0.6MPa\uff08\u7ea66\uff5e8\u516c\u65a4\uff09\u4fdd\u538b24\u5c0f\u65f6\uff0c\u538b\u964d\u4e0d\u5927\u4e8e0.05MPa\u4e14\u65e0\u4efb\u4f55\u6e17\u6f0f\u6e7f\u75d5\uff0c\u5e76\u5206\u4e09\u6b21\u6253\u538b\uff1a\u7ba1\u8def\u8fde\u597d\u540e\u3001\u6696\u6c14\u7247\u6302\u5b8c\u540e\u3001\u8c03\u8bd5\u8fd0\u884c\u540e\u590d\u9a8c\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5c0f\u6237\u578b\u9505\u7089\u8001\u662f\u81ea\u5df1\u542f\u505c\uff0c\u4ec0\u4e48\u539f\u56e0\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u591a\u6570\u662f\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u9ad8\u4e8e\u623f\u95f4\u70ed\u8d1f\u8377\uff1a\u5c0f\u6237\u578b\u70ed\u8d1f\u8377\u5f80\u5f80\u53ea\u67093\uff5e5kW\uff0c\u5e38\u89c424kW\u4e24\u7528\u7089\u6700\u5c0f\u8f93\u51fa\u7ea68\uff5e10kW\uff0c\u9505\u7089\u53ea\u80fd\u9891\u7e41\u542f\u505c\u3002\u89e3\u6cd5\u662f\u9009\u6700\u5c0f\u8f93\u51fa\u66f4\u4f4e\u7684\u5355\u91c7\u6696\u7089\u6216\u53d8\u9891\u7089\uff08\u53d8\u9891\u7089\u6700\u5c0f\u8f93\u51fa\u53ef\u4f4e\u81f35.6kW\uff09\uff0c\u518d\u914d\u8054\u52a8\u63a7\u5236\uff0c\u5ba4\u6e29\u5230\u8bbe\u5b9a\u503c\u9505\u7089\u5c31\u505c\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u8001\u623f\u5b50\u7684\u8f7b\u8d28\u5899\u3001\u52a0\u6c14\u5757\u5899\uff0c\u80fd\u6302\u6696\u6c14\u7247\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u80fd\uff0c\u4f46\u4e0d\u80fd\u7528\u666e\u901a\u5851\u6599\u80c0\u585e\u51d1\u5408\u3002\u6696\u6c14\u7247\u6ce8\u6c34\u540e\u4e00\u7ec425\uff5e50\u516c\u65a4\uff0c\u52a0\u6c14\u6df7\u51dd\u571f\u780c\u5757\u3001\u8f7b\u8d28\u9694\u5899\u8981\u91c7\u7528\u7a7f\u5899\u5bf9\u62c9\u87ba\u6813\u3001\u5730\u9762\u652f\u6491\u652f\u67b6\u6216\u5c40\u90e8\u52a0\u56fa\uff0c\u4fdd\u8bc1\u6ee1\u8f7d\u91cd\u91cf2\uff5e3\u500d\u7684\u627f\u91cd\u80fd\u529b\uff1b\u52d8\u67e5\u9636\u6bb5\u5148\u6d4b\u5899\u4f53\u6750\u8d28\uff0c\u6302\u4e0d\u4f4f\u7684\u4f4d\u7f6e\u8c03\u6574\u65b9\u6848\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u8fd9\u5957\u4e0b\u6765\u5927\u6982\u591a\u5c11\u94b1\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6309\u6696\u6c14\u7247\u7ec4\u6570\u548c\u9505\u7089\u578b\u53f7\u8ba1\u7b97\u3002\u5b98\u7f51\u6709\u5957\u9910\u4ef7\uff083\u7ec4\u6696\u6c14\u7247\u4e00\u4ef7\u5168\u5305\u3001\u8001\u623f\u6700\u5feb\u5f53\u5929\u88c5\u597d\uff09\u548c\u771f\u5b9e\u6848\u4f8b\u7684\u660e\u7ec6\u53ef\u67e5\uff1b\u65bd\u5de5\u6807\u51c6\u4ee5\u9875\u9762\u6240\u5217\u6d41\u7a0b\u4e3a\u51c6\uff0c\u4ef7\u683c\u4e0d\u540c\u3001\u5de5\u827a\u4e0d\u6253\u6298\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n\n\t\n\t\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u4e00\u3001\u5148\u8bf4\u7ed3\u8bba\uff1a\u660e\u88c5\u6696\u6c14\u88c5\u5f97\u597d\u4e0d\u597d\uff0c\u770b\u4e09\u4ef6 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-15413","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u9690\u853d\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u70df\u7ba1\u5761\u5ea6\u4e0e\u71c3\u6c14\u68c0\u6f0f\u3001\u6253\u538b0.6MPa\u4fdd\u538b24\u5c0f\u65f6\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u7559\u75d5\uff0c\u6bcf\u6b65\u6709\u6807\u51c6\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=15413\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u9690\u853d\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u70df\u7ba1\u5761\u5ea6\u4e0e\u71c3\u6c14\u68c0\u6f0f\u3001\u6253\u538b0.6MPa\u4fdd\u538b24\u5c0f\u65f6\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u7559\u75d5\uff0c\u6bcf\u6b65\u6709\u6807\u51c6\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=15413\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-20T10:17:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-1.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413\",\"name\":\"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/GLAZSJT-1.jpg\",\"datePublished\":\"2026-10-17T11:00:26+00:00\",\"dateModified\":\"2026-10-20T10:17:35+00:00\",\"description\":\"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u9690\u853d\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u70df\u7ba1\u5761\u5ea6\u4e0e\u71c3\u6c14\u68c0\u6f0f\u3001\u6253\u538b0.6MPa\u4fdd\u538b24\u5c0f\u65f6\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u7559\u75d5\uff0c\u6bcf\u6b65\u6709\u6807\u51c6\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/GLAZSJT-1.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/GLAZSJT-1.jpg\",\"width\":1280,\"height\":1280},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15413#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u9690\u853d\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u70df\u7ba1\u5761\u5ea6\u4e0e\u71c3\u6c14\u68c0\u6f0f\u3001\u6253\u538b0.6MPa\u4fdd\u538b24\u5c0f\u65f6\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u7559\u75d5\uff0c\u6bcf\u6b65\u6709\u6807\u51c6\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=15413","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u9690\u853d\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u70df\u7ba1\u5761\u5ea6\u4e0e\u71c3\u6c14\u68c0\u6f0f\u3001\u6253\u538b0.6MPa\u4fdd\u538b24\u5c0f\u65f6\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u7559\u75d5\uff0c\u6bcf\u6b65\u6709\u6807\u51c6\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=15413","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-20T10:17:35+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-1.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=15413","url":"https:\/\/longmai-nt.com\/?page_id=15413","name":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=15413#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=15413#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-1.jpg","datePublished":"2026-10-17T11:00:26+00:00","dateModified":"2026-10-20T10:17:35+00:00","description":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff1a\u52d8\u67e5\u8bbe\u8ba1\u3001\u7ba1\u8def\u9690\u853d\u3001\u6696\u6c14\u7247\u6302\u88c5\u3001\u58c1\u6302\u7089\u70df\u7ba1\u5761\u5ea6\u4e0e\u71c3\u6c14\u68c0\u6f0f\u3001\u6253\u538b0.6MPa\u4fdd\u538b24\u5c0f\u65f6\u3001\u7cfb\u7edf\u8c03\u8bd5\u3001\u9a8c\u6536\u7559\u75d5\uff0c\u6bcf\u6b65\u6709\u6807\u51c6\uff0c\u9a8c\u6536\u4e0d\u5408\u683c\u4e0d\u4ea4\u4ed8\u3002\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=15413#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=15413"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=15413#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-1.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/GLAZSJT-1.jpg","width":1280,"height":1280},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=15413#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15413","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15413"}],"version-history":[{"count":7,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15413\/revisions"}],"predecessor-version":[{"id":15826,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15413\/revisions\/15826"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15413"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}