{"id":15688,"date":"2026-10-19T14:12:43","date_gmt":"2026-10-19T06:12:43","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=15688"},"modified":"2026-10-19T14:12:44","modified_gmt":"2026-10-19T06:12:44","slug":"%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e5%8f%8c%e6%96%b9%e6%a1%88%e6%8a%a5%e4%bb%b7-2","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=15688","title":{"rendered":"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7"},"content":{"rendered":"\n\n<!-- \u3010\u5185\u90e8\u6ce8\u91ca \u00b7 \u53d1\u5e03\u7c98\u8d34\u524d\u8bf7\u6574\u5757\u5220\u9664\uff0c\u52ff\u968f\u6b63\u6587\u8fdb\u5165 WordPress\u3011\n  ============================================================================\n  \u9f99\u8109\u6696\u901a \u00b7 \u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66\uff08\u65b9\u6848\u4e66\u6a21\u7248 V3 \u00b7 \u7ea2\u91d1\u53cc\u65b9\u6848\u578b\uff0c\u6e90\u81ea page_id=11788\uff09\n  \u9879\u76ee\uff1a\u6210\u90fd \u00b7 \u91d1\u8302\u6653\u68e0 \u00b7 \u5411\u5973\u58eb \u00b7 \u5e73\u5c42 \u00b7 \u7a7a\u8c03\u9762\u79ef 85\u33a1\uff0852\/16\/8\/9\uff09\n  \u914d\u7f6e\uff1a\u65e5\u7acb 125 \u4e3b\u673a\u4e00\u62d6\u56db\uff0c\u5185\u673a 71 \/ 36 \/ 22 \/ 22\uff0c\u5185\u673a\u603b\u80fd\u529b 15.1kW\uff0c\u8fde\u63a5\u7387 120.8%\n  \u65b9\u6848\u4e00\uff1aEX-\u8212\u4eab 125 \u5355\u98ce\u6247 RAS-125HRNAQ\uff08PE \u51c0\u5316\u6a21\u5757\u5217\u4e3a\u9009\u914d\uff09\u2192 26,861.60\uff08\u542b PE \u5219 28,461.60\uff09\n  \u65b9\u6848\u4e8c\uff1aVAM \u5c0a\u777f\u5168\u6548 125 RAS-125FSXPN5Q \u4e09\u7ba1\u5236\u4e00\u62d6\u56db \u2192 41,530.40\n  \u4ef7\u5dee 14,668.80\u3002\u6c34\u6a21\u5757\u4e0e\u5730\u6696\u7cfb\u7edf\u4e0d\u5728\u672c\u518c\u62a5\u4ef7\u8303\u56f4\u5185\uff0c\u53e6\u9644\u3002\n  ----------------------------------------------------------------------------\n  \u4e0e\u6e90\u6a21\u677f\uff08page_id=11788\uff09\u7684\u5dee\u5f02\uff08\u5747\u5df2\u6309\u53d1\u5e03\u536b\u751f\u6807\u51c6\u5904\u7406\uff09\uff1a\n   1. \u62a5\u4ef7\u8868\u7531 8 \u5217\uff08\u9762\u4ef7\/\u6298\u6263\/\u6298\u540e\u4ef7\uff09\u6539\u4e3a 6 \u5217\uff08\u8bbe\u5907\u4ef7\/\u5b89\u88c5\u8d39\/\u5c0f\u8ba1\uff09\uff0c\u5168\u7bc7\u53bb\u6298\u6263\u53e3\u5f84\n   2. \u7ae0\u8282\u6807\u9898\u53bb\u6389\u300c\u8bbe\u5907\u7edf\u4e00 8 \u6298\u300d\u300c2026 \u7248\u6210\u672c\u8868\u300d\u5b57\u6837\n   3. \u5168\u7ad9 CSS \u52a0 .lmv3 \u4f5c\u7528\u57df\uff0c\u907f\u514d\u7c98\u8fdb WP \u91cd\u6392\u6574\u7ad9\n   4. \u8865 h1\u3001JSON-LD\uff08Article\uff0bFAQPage\uff09\u3001\u65b9\u6848\u4e66\u6027\u8d28\u8bf4\u660e\u3001\u9875\u811a\u514d\u8d23\n   5. \u6a2a\u8bc4\u300c\u81ea\u4ea7\u6da1\u65cb\u538b\u7f29\u673a\u300d\u6539\u4e3a\u300c\u81ea\u4ea7\u53cc\u8f6c\u5b50\uff08125 \u53ca\u4ee5\u4e0b\uff09\uff0f\u6da1\u65cb\uff08\u5927\u5bb9\u91cf\uff09\u300d\n   6. \u65b0\u589e\u300c\u91c7\u6696\u5206\u5de5\u300d\u300c\u5730\u6696\u63a5\u53e3\u300d\u4e24\u8282\uff08\u672c\u6848\u6838\u5fc3\uff1a\u7a7a\u8c03\u53ea\u5236\u51b7\u3001\u91c7\u6696\u4ea4\u5730\u6696\uff09\n   7. \u4fdd\u7559\u6c34\u6a21\u5757\u4ea7\u54c1\u5361\uff08\u672c\u6848\u6709\u5730\u6696\u9700\u6c42\uff09\uff0c\u6309\u94c1\u5f8b 14 \u6b63\u9762\u8868\u8ff0\n  ============================================================================\n-->\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"\u5411\u5973\u58eb \u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66\uff08\u91d1\u8302\u6653\u68e0 85\u33a1 \u00b7 \u65e5\u7acb\u8212\u4eab125 \u4e0e \u5c0a\u777f\u5168\u6548125 \u53cc\u65b9\u6848\u5bf9\u6bd4\uff09\",\n      \"description\": \"\u6210\u90fd\u91d1\u8302\u6653\u68e0\u5411\u5973\u58eb\u5e73\u5c42\uff0c\u7a7a\u8c03\u8986\u76d6\u9762\u79ef\u7ea685\u5e73\u65b9\u7c73\uff0c\u5ba2\u9910\u5385\u53a8\u623f52\u5e73\u65b9\u7c73\u914d71\u578b\uff0c\u4e3b\u536716\u5e73\u65b9\u7c73\u914d36\u578b\uff0c\u513f\u7ae5\u623f8\u5e73\u65b9\u7c73\u4e0e\u6b21\u53679\u5e73\u65b9\u7c73\u5404\u914d22\u578b\uff0c\u4e3b\u673a\u4e3a\u65e5\u7acb125\u3002\u5185\u673a\u603b\u80fd\u529b15.1\u5343\u74e6\uff0c\u8fde\u63a5\u7387120.8%\u3002\u7a7a\u8c03\u4ee5\u5236\u51b7\u4e3a\u4e3b\uff0c\u51ac\u5b63\u91c7\u6696\u4ea4\u7531\u5730\u6696\u627f\u62c5\u3002\u65b9\u6848\u4e00\u4e3a\u65e5\u7acbEX-\u8212\u4eab125\u5355\u98ce\u6247\u4e00\u62d6\u56db\uff1b\u65b9\u6848\u4e8c\u4e3a\u65e5\u7acbVAM\u5c0a\u777f\u5168\u6548125\u4e09\u7ba1\u5236\u4e00\u62d6\u56db\uff0c\u5e76\u9884\u7559\u6c34\u6a21\u5757\u63a5\u53e3\u4ee5\u652f\u6301\u5929\u6c1f\u5730\u6c34\u3002\u4e24\u65b9\u6848\u5dee\u4ef714,668.80\u5143\u3002\",\n      \"author\": { \"@type\": \"Person\", \"name\": \"\u4f59\u6653\u73b2\", \"jobTitle\": \"\u6696\u901a\u8bbe\u8ba1\u5e08\", \"telephone\": \"130-0811-3409\" },\n      \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"\u9f99\u8109\u6696\u901a\",\n        \"logo\": { \"@type\": \"ImageObject\", \"url\": \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" }\n      },\n      \"datePublished\": \"2026-10-19\",\n      \"dateModified\": \"2026-10-19\",\n      \"mainEntityOfPage\": { \"@type\": \"WebPage\", \"@id\": \"https:\/\/longmai-nt.com\/?page_id=PENDING_PUBLISH_ID\" },\n      \"about\": { \"@type\": \"Thing\", \"name\": \"\u4f4f\u5b85\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u8bbe\u8ba1\uff08\u4ee5\u5236\u51b7\u4e3a\u4e3b\u7684\u914d\u7f6e\u9009\u578b\u4e0e\u5730\u6696\u70ed\u6e90\u8854\u63a5\uff09\" }\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u7a7a\u8c03\u53ea\u505a\u5236\u51b7\uff0c\u6210\u90fd\u51ac\u5929\u4e0d\u9760\u5b83\u884c\u4e0d\u884c\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u884c\uff0c\u800c\u4e14\u8fd9\u662f\u66f4\u5408\u7406\u7684\u5206\u5de5\u3002\u6210\u90fd\u51ac\u5b63\u5ba4\u5916\u591a\u5728 0 \u5230 8 \u6444\u6c0f\u5ea6\uff0c\u91c7\u6696\u9700\u6c42\u96c6\u4e2d\u5728 12 \u6708\u5230 2 \u6708\u3002\u5730\u6696\u7528 35 \u5230 45 \u6444\u6c0f\u5ea6\u7684\u4f4e\u6e29\u6c34\u5faa\u73af\uff0c\u70ed\u91cf\u4ece\u5730\u9762\u5f80\u4e0a\u8f90\u5c04\uff0c\u811a\u6696\u5934\u51c9\uff0c\u6ca1\u6709\u5439\u98ce\u611f\uff0c\u4e5f\u6ca1\u6709\u5316\u971c\u505c\u673a\u3002\u7a7a\u8c03\u5236\u70ed\u9760\u9001\u70ed\u98ce\uff0c\u70ed\u7a7a\u6c14\u4f1a\u6d6e\u5728\u623f\u95f4\u4e0a\u90e8\uff0c\u5bb9\u6613\u51fa\u73b0\u5934\u70ed\u811a\u51b7\uff1b\u5ba4\u5916\u673a\u7ed3\u971c\u65f6\u8981\u53cd\u5411\u5316\u971c\uff0c\u5316\u971c\u90a3\u51e0\u5206\u949f\u5ba4\u5185\u662f\u505c\u98ce\u7684\u3002\u6240\u4ee5\u672c\u6848\u628a 3 \u4e2a\u6708\u7684\u91c7\u6696\u4ea4\u7ed9\u5730\u6696\uff0c\u7a7a\u8c03\u8d1f\u8d23\u590f\u5b63 3 \u4e2a\u6708\u7684\u5236\u51b7\uff0c\u4ee5\u53ca\u6625\u79cb\u8fc7\u6e21\u5b63\u5076\u5c14\u964d\u6e29\u65f6\u7684\u77ed\u65f6\u4f7f\u7528\u3002\u4e24\u6761\u7cfb\u7edf\u5404\u505a\u5404\u7684\u64c5\u957f\u9879\uff0c\u4f53\u9a8c\u548c\u80fd\u8017\u90fd\u66f4\u597d\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u8fde\u63a5\u7387 120.8% \u4f1a\u4e0d\u4f1a\u5e26\u4e0d\u52a8\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e0d\u4f1a\u3002\u8fde\u63a5\u7387\u662f\u56db\u53f0\u5185\u673a\u989d\u5b9a\u5236\u51b7\u91cf\u4e4b\u548c 15.1 \u5343\u74e6\uff0c\u9664\u4ee5\u4e3b\u673a\u989d\u5b9a\u5236\u51b7\u91cf 12.5 \u5343\u74e6\uff0c\u7b49\u4e8e 120.8%\uff0c\u5728\u6c1f\u673a 90% \u5230 130% \u7684\u5408\u7406\u533a\u95f4\u5185\u3002\u8fd9\u4e2a\u6bd4\u503c\u9ad8\u4e8e 1 \u7684\u524d\u63d0\u662f\u5404\u623f\u95f4\u4e0d\u4f1a\u540c\u65f6\u6ee1\u8f7d\uff1a\u767d\u5929\u4ee5\u5ba2\u9910\u5385\u53a8\u623f\u4e3a\u4e3b\uff0c\u591c\u95f4\u4ee5\u4e09\u95f4\u5367\u5ba4\u4e3a\u4e3b\uff0c\u5b9e\u9645\u540c\u5f00\u7387\u901a\u5e38\u5728 60% \u5230 80%\u3002\u9700\u8981\u63d0\u9192\u7684\u662f\uff0c\u5982\u679c\u590f\u5929\u508d\u665a\u5ba2\u5385\u548c\u4e09\u4e2a\u5367\u5ba4\u540c\u65f6\u5168\u5f00\u3001\u4e14\u90fd\u8bbe\u5230\u5f88\u4f4e\u7684\u6e29\u5ea6\uff0c\u7cfb\u7edf\u4f1a\u628a\u80fd\u529b\u4f18\u5148\u5206\u914d\u7ed9\u6b63\u5728\u4f7f\u7528\u7684\u623f\u95f4\uff0c\u4e0d\u4f1a\u505c\u673a\uff0c\u4f46\u964d\u6e29\u901f\u5ea6\u4f1a\u6bd4\u5355\u5f00\u65f6\u6162\u4e00\u4e9b\u3002\u8fd9\u662f 125 \u4e3b\u673a\u7684\u6b63\u5e38\u8868\u73b0\uff0c\u4e0d\u662f\u6545\u969c\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u513f\u7ae5\u623f 8 \u5e73\u65b9\u7c73\u914d 22 \u578b\uff0c\u4f1a\u4e0d\u4f1a\u592a\u5927\u3001\u4f1a\u4e0d\u4f1a\u592a\u51b7\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u4e0d\u4f1a\u592a\u51b7\u300222 \u578b\u662f\u65e5\u7acb\u4e00\u62d6\u591a\u7cfb\u7edf\u91cc\u6700\u5c0f\u7684\u6807\u51c6\u5185\u673a\uff0c8 \u5e73\u65b9\u7c73\u6309 220 \u74e6\u6bcf\u5e73\u65b9\u7c73\u7684\u4e0a\u9650\u7b97\u4e5f\u53ea\u9700\u8981 1.76 \u5343\u74e6\uff0c\u914d 22 \u578b\u662f\u5c31\u8fd1\u53d6\u6574\u7684\u5fc5\u7136\u7ed3\u679c\uff0c\u4e0d\u662f\u523b\u610f\u914d\u5927\u3002\u5b9e\u9645\u4f7f\u7528\u4e2d\uff0c\u623f\u95f4\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6\u540e\u4e3b\u673a\u4f1a\u81ea\u52a8\u964d\u9891\uff0c\u5185\u673a\u7684\u7535\u5b50\u81a8\u80c0\u9600\u540c\u6b65\u6536\u5c0f\uff0c\u8f93\u51fa\u8fdc\u4f4e\u4e8e\u989d\u5b9a\u503c\u3002\u771f\u6b63\u8981\u907f\u514d\u7684\u662f\u53e6\u4e00\u4ef6\u4e8b\uff1a\u4e0d\u8981\u4e3a\u4e86\u7701\u51e0\u767e\u5143\u628a 8 \u5e73\u65b9\u7c73\u914d\u5230\u6ca1\u6709\u66f4\u5c0f\u673a\u578b\u53ef\u9009\u7684\u56f0\u5883\u91cc\uff0c\u4e5f\u4e0d\u8981\u56e0\u4e3a\u673a\u5668\u5927\u5c31\u957f\u671f\u628a\u6e29\u5ea6\u8bbe\u5230 22 \u5ea6\u4ee5\u4e0b\uff0c\u90a3\u624d\u4f1a\u89c9\u5f97\u51b7\u3002\u8bbe\u5b9a 26 \u5ea6\u52a0\u81ea\u52a8\u98ce\uff0c\u4f53\u611f\u6700\u8212\u670d\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u8212\u4eab\u548c\u5c0a\u777f\u5168\u6548\u5dee\u4e00\u4e07\u56db\uff0c\u5230\u5e95\u5dee\u5728\u54ea\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u5dee\u5728\u4e09\u4ef6\u4e8b\uff0c\u90fd\u4e0d\u662f\u57fa\u7840\u5236\u51b7\u80fd\u529b\u3002\u7b2c\u4e00\u662f\u9664\u6e7f\u65b9\u5f0f\uff1a\u5c0a\u777f\u5168\u6548\u662f\u4e09\u7ba1\u5236\uff0c\u53ef\u4ee5\u5728 18 \u6444\u6c0f\u5ea6\u4e0d\u964d\u6e29\u7684\u60c5\u51b5\u4e0b\u9664\u6e7f\uff0c\u8212\u4eab\u662f\u964d\u6e29\u9664\u6e7f\uff0c\u9664\u6e7f\u65f6\u623f\u95f4\u4f1a\u8ddf\u7740\u53d8\u51c9\uff1b\u7b2c\u4e8c\u662f\u51c0\u5316\u5c42\u7ea7\uff1a\u5c0a\u777f\u5168\u6548\u51fa\u5382\u81ea\u5e26\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0c\u542b PE+ \u51c0\u5316\u3001\u81ea\u6e05\u6d01\u4e0e 60 \u6444\u6c0f\u5ea6\u9664\u83cc\uff0c\u8212\u4eab\u8981\u53e6\u914d PE \u6a21\u5757\u624d\u80fd\u8fbe\u5230\u63a5\u8fd1\u7684\u6548\u679c\uff1b\u7b2c\u4e09\u662f\u5730\u6696\u63a5\u53e3\uff1a\u5c0a\u777f\u5168\u6548\u53ef\u4ee5\u52a0\u88c5\u6c34\u6a21\u5757\u505a\u5929\u6c1f\u5730\u6c34\uff0c\u4e00\u53f0\u4e3b\u673a\u540c\u65f6\u5e26\u7a7a\u8c03\u548c\u5730\u6696\uff0c\u8212\u4eab\u53ea\u80fd\u53e6\u914d\u71c3\u6c14\u58c1\u6302\u7089\u3002\u5c31\u60a8\u4ee5\u5236\u51b7\u4e3a\u4e3b\u3001\u53c8\u8981\u505a\u5730\u6696\u7684\u60c5\u51b5\u770b\uff0c\u8fd9\u7b14\u5dee\u4ef7\u4e70\u7684\u4e3b\u8981\u662f\u9664\u6e7f\u4f53\u611f\u548c\u5730\u6696\u70ed\u6e90\u7684\u9009\u62e9\u6743\uff0c\u4e0d\u662f\u5236\u51b7\u80fd\u529b\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u73b0\u5728\u88c5\u7a7a\u8c03\uff0c\u5730\u6696\u8fc7\u4e24\u5e74\u518d\u52a0\u884c\u4e0d\u884c\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u8981\u5206\u4e24\u4ef6\u4e8b\u8bf4\u3002\u5730\u6696\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u548c\u4e3b\u7ba1\u5fc5\u987b\u4e0e\u88c5\u4fee\u540c\u6b65\u505a\uff0c\u56e0\u4e3a\u76d8\u7ba1\u57cb\u5728\u5730\u9762\u627e\u5e73\u5c42\u91cc\uff0c\u88c5\u4fee\u5b8c\u6210\u540e\u518d\u52a0\u5c31\u8981\u62c6\u5730\u9762\uff0c\u4ee3\u4ef7\u5f88\u5927\u3002\u70ed\u6e90\u53ef\u4ee5\u540e\u5b9a\uff0c\u4f46\u63a5\u53e3\u8981\u73b0\u5728\u7559\uff1a\u9009\u65b9\u6848\u4e00\uff0c\u5c31\u5728\u53a8\u623f\u6216\u751f\u6d3b\u9633\u53f0\u9884\u7559\u71c3\u6c14\u58c1\u6302\u7089\u7684\u4f4d\u7f6e\u3001\u70df\u9053\u5b54\u548c\u71c3\u6c14\u63a5\u53e3\uff1b\u9009\u65b9\u6848\u4e8c\uff0c\u5c31\u8981\u5728\u5916\u673a\u4fa7\u9884\u7559\u6c34\u6a21\u5757\u7684\u5b89\u88c5\u4f4d\u4e0e\u51b7\u5a92\u7ba1\u63a5\u53e3\uff0c\u56e0\u4e3a\u5929\u6c1f\u5730\u6c34\u7684\u6c34\u6a21\u5757\u5fc5\u987b\u4e0e\u4e3b\u673a\u540c\u4e00\u5957\u51b7\u5a92\u7cfb\u7edf\u3002\u6240\u4ee5\u771f\u6b63\u7684\u51b3\u7b56\u70b9\u662f\u4eca\u5929\u9009\u54ea\u53f0\u4e3b\u673a\uff0c\u800c\u4e0d\u662f\u4ee5\u540e\u4e70\u4e0d\u4e70\u9505\u7089\u3002\" }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u65e5\u7acb\u6bd4\u683c\u529b\u3001\u7f8e\u7684\u8d35\u591a\u5c11\uff0c\u8d35\u5728\u54ea\uff1f\",\n          \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"\u540c\u6237\u578b\u65e5\u7acb\u7684\u4ef7\u683c\u901a\u5e38\u6bd4\u683c\u529b\u3001\u7f8e\u7684\u9ad8\u7ea6\u767e\u5206\u4e4b\u5341\u5230\u5341\u4e94\uff0c\u6bd4\u5927\u91d1\u4fbf\u5b9c\u767e\u5206\u4e4b\u5341\u4e94\u5230\u4e09\u5341\u4e94\u3002\u8d35\u7684\u90e8\u5206\u4e3b\u8981\u5728\u56db\u4ef6\u4e8b\uff1a\u4e00\u662f\u81ea\u4ea7\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u4e0e\u4e24\u5343\u7ea7\u7535\u5b50\u81a8\u80c0\u9600\uff0c\u7cfb\u7edf\u5728\u90e8\u5206\u8d1f\u8377\u4e0b\u66f4\u7a33\u3001\u66f4\u7701\u7535\uff1b\u4e8c\u662f\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u52a0\u6d6e\u5b50\u5f00\u5173\uff0c\u53cc\u91cd\u9632\u6ce1\u9876\uff1b\u4e09\u662f\u5341\u6444\u6c0f\u5ea6\u4f4e\u6e29\u9664\u6e7f\u4e0e\u4e94\u5341\u516d\u6863\u6e7f\u5ea6\u8c03\u8282\uff0c\u6210\u90fd\u56de\u5357\u5929\u80fd\u7528\uff1b\u56db\u662f\u5185\u673a\u6700\u4f4e\u5341\u4e03\u5206\u8d1d\u7684\u9759\u97f3\u6c34\u5e73\u3002\u8fd9\u56db\u9879\u90fd\u4e0d\u4f53\u73b0\u5728\u5236\u51b7\u91cf\u4e0a\uff0c\u4f46\u51b3\u5b9a\u4e86\u4e94\u5e74\u3001\u5341\u5e74\u540e\u8fd9\u5957\u7cfb\u7edf\u8fd8\u7701\u4e0d\u7701\u5fc3\u3002\" }\n        }\n      ]\n    }\n  ]\n}\n<\/script>\n\n<style>\n\/* ===== \u9f99\u8109\u6696\u901a \u65b9\u6848\u4e66\u6a21\u7248 V3 \u00b7 \u7ea2\u91d1\u4f53\u7cfb\uff08\u5168\u90e8\u4f5c\u7528\u57df\u9650\u5b9a\u5728 .lmv3 \u5185\uff09 ===== *\/\n.lmv3{\n  --red:#c8102e; --red-d:#9e0c24; --gold:#b8860b; --ink:#1f2329;\n  --gray:#6b7280; --line:#e7e3dc; --bg:#f6f4ef; --card:#ffffff;\n  --green:#1e8e5a;\n  font-family:\"PingFang SC\",\"Microsoft YaHei\",\"Hiragino Sans GB\",sans-serif;\n  color:var(--ink); background:var(--bg); line-height:1.7; -webkit-font-smoothing:antialiased;\n}\n.lmv3 *{box-sizing:border-box;}\n.lmv3 .wrap{max-width:1040px;margin:0 auto;padding:0 18px 64px;}\n.lmv3 header.hero{background:linear-gradient(135deg,var(--red) 0%,var(--red-d) 100%);color:#fff;\n  padding:38px 24px 30px;text-align:center;}\n.lmv3 header.hero .badge{display:inline-block;font-size:13px;letter-spacing:2px;opacity:.85;\n  border:1px solid rgba(255,255,255,.5);padding:4px 14px;border-radius:20px;margin-bottom:14px;}\n.lmv3 header.hero h1{margin:0 0 8px;font-size:30px;letter-spacing:1px;font-weight:600;}\n.lmv3 header.hero p{margin:4px 0;opacity:.92;font-size:15px;}\n.lmv3 header.hero .sub{margin-top:10px;font-size:13.5px;opacity:.8;}\n.lmv3 section{background:var(--card);border:1px solid var(--line);border-radius:14px;\n  padding:26px 26px;margin:22px 0;box-shadow:0 2px 14px rgba(0,0,0,.04);}\n.lmv3 h2.sec{font-size:21px;margin:0 0 6px;padding-left:12px;border-left:5px solid var(--red);font-weight:600;}\n.lmv3 h2.sec small{font-weight:400;color:var(--gray);font-size:13px;margin-left:8px;}\n.lmv3 .lead{color:var(--gray);font-size:14px;margin:0 0 18px;}\n\n\/* \u53cc\u65b9\u6848\u6982\u89c8 *\/\n.lmv3 .plans{display:grid;grid-template-columns:1fr 1fr;gap:18px;}\n.lmv3 .plan{border:1px solid var(--line);border-radius:12px;overflow:hidden;}\n.lmv3 .plan .ph{padding:16px 18px;color:#fff;}\n.lmv3 .plan.a .ph{background:linear-gradient(135deg,#d98a1f,#b8860b);}\n.lmv3 .plan.b .ph{background:linear-gradient(135deg,var(--red),var(--red-d));}\n.lmv3 .plan .ph h3{margin:0;font-size:18px;}\n.lmv3 .plan .ph .tag{font-size:12px;opacity:.9;}\n.lmv3 .plan .pb{padding:16px 18px;font-size:14px;}\n.lmv3 .plan .pb ul{margin:8px 0 0;padding-left:18px;}\n.lmv3 .plan .pb li{margin:3px 0;}\n.lmv3 .kv{display:flex;justify-content:space-between;border-bottom:1px dashed var(--line);padding:5px 0;font-size:13px;gap:12px;}\n.lmv3 .kv span:first-child{color:var(--gray);flex-shrink:0;}\n.lmv3 .kv span:last-child{text-align:right;}\n\n\/* \u8868\u683c *\/\n.lmv3 table{width:100%;border-collapse:collapse;font-size:13.5px;margin-top:8px;}\n.lmv3 th,.lmv3 td{border:1px solid var(--line);padding:9px 10px;text-align:center;}\n.lmv3 th{background:#faf7f1;color:var(--ink);font-weight:600;}\n.lmv3 tbody tr:nth-child(even){background:#fcfbf8;}\n.lmv3 td.area{text-align:left;font-weight:600;}\n.lmv3 td.tl{text-align:left;}\n.lmv3 .note{background:#faf7f1;border:1px dashed var(--gold);border-radius:10px;padding:12px 16px;\n  font-size:13px;color:#5a4a1a;margin-top:14px;}\n.lmv3 .ctrl td{background:#fff8e1;font-weight:600;}\n\n\/* \u4ea7\u54c1\u5361\u724c\u7ffb\u8f6c *\/\n.lmv3 .cards{display:grid;grid-template-columns:repeat(3,1fr);gap:16px;}\n.lmv3 .flip{perspective:1200px;height:300px;cursor:pointer;}\n.lmv3 .flip-inner{position:relative;width:100%;height:100%;transition:transform .6s;transform-style:preserve-3d;}\n.lmv3 .flip:hover .flip-inner,.lmv3 .flip:focus-within .flip-inner{transform:rotateY(180deg);}\n.lmv3 .face{position:absolute;inset:0;backface-visibility:hidden;-webkit-backface-visibility:hidden;\n  border-radius:12px;overflow:hidden;border:1px solid var(--line);background:#fff;display:flex;flex-direction:column;}\n.lmv3 .face.back{transform:rotateY(180deg);background:#fff;padding:16px;justify-content:center;}\n.lmv3 .face img{width:100%;height:200px;object-fit:contain;background:#f4f4f4;}\n.lmv3 .face .cap{text-align:center;padding:10px;font-weight:600;font-size:14px;}\n.lmv3 .face.back h4{margin:0 0 8px;color:var(--red);font-size:15px;}\n.lmv3 .face.back ul{margin:0;padding-left:16px;font-size:12.5px;color:#444;}\n.lmv3 .face.back li{margin:4px 0;}\n.lmv3 .flip-hint{text-align:center;color:var(--gray);font-size:12px;margin-top:10px;}\n\n\/* \u65bd\u5de5\u8fc7\u7a0b *\/\n.lmv3 .gallery{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;}\n.lmv3 .gallery figure{margin:0;border:1px solid var(--line);border-radius:10px;overflow:hidden;background:#fff;}\n.lmv3 .gallery img{width:100%;height:180px;object-fit:cover;display:block;}\n.lmv3 .gallery figcaption{font-size:12.5px;padding:8px 10px;color:#444;background:#faf7f1;}\n\n\/* \u62a5\u4ef7 *\/\n.lmv3 .quote{margin-top:18px;}\n.lmv3 .qhead{font-weight:700;color:var(--red);font-size:16px;margin:18px 0 6px;}\n.lmv3 .total{background:linear-gradient(135deg,#fff7e8,#fdeccb);border:1px solid var(--gold);\n  border-radius:10px;padding:12px 16px;font-size:15px;font-weight:700;text-align:right;margin-top:6px;}\n.lmv3 .vs{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin-top:16px;}\n.lmv3 .vs .box{border:1px solid var(--line);border-radius:10px;padding:14px 16px;}\n.lmv3 .vs .box.a{border-top:4px solid var(--gold);}\n.lmv3 .vs .box.b{border-top:4px solid var(--red);}\n.lmv3 .vs .box h4{margin:0 0 6px;font-size:15px;}\n.lmv3 .vs .box .big{font-size:22px;font-weight:800;}\n.lmv3 .vs .box.a .big{color:var(--gold);}\n.lmv3 .vs .box.b .big{color:var(--red);}\n\n\/* \u521d\u6295\u6784\u6210\u5806\u53e0\u6761 *\/\n.lmv3 .stack{margin:18px 0 4px;}\n.lmv3 .stack-t{font-size:14px;font-weight:700;color:#2a2f38;margin:0 0 10px;line-height:1.6;}\n.lmv3 .stack-row{display:flex;align-items:center;gap:10px;margin:8px 0;}\n.lmv3 .stack-name{width:88px;flex-shrink:0;font-size:13px;font-weight:600;color:#444;}\n.lmv3 .stack-bar{flex:1;display:flex;height:34px;border-radius:6px;overflow:hidden;background:#f2efe8;}\n.lmv3 .stack-bar span{display:block;min-width:4px;color:#fff;font-size:11.5px;line-height:34px;text-align:center;overflow:hidden;}\n.lmv3 .stack-sum{width:96px;flex-shrink:0;text-align:right;font-size:13px;font-weight:700;color:#8a6a12;}\n.lmv3 .stack-lg{display:flex;flex-wrap:wrap;gap:16px;font-size:12px;color:#555;margin-top:12px;}\n.lmv3 .stack-lg i{display:inline-block;width:11px;height:11px;border-radius:2px;margin-right:5px;vertical-align:-1px;}\n.lmv3 .stack-read{font-size:12.5px;color:var(--gray);margin:10px 0 0;line-height:1.7;}\n\n\/* \u987e\u95ee *\/\n.lmv3 .consult{display:flex;align-items:center;gap:16px;flex-wrap:wrap;}\n.lmv3 .consult .av{width:54px;height:54px;border-radius:50%;background:var(--red);color:#fff;\n  display:flex;align-items:center;justify-content:center;font-size:22px;font-weight:700;}\n.lmv3 .consult .info b{font-size:17px;}\n.lmv3 .consult .info span{color:var(--gray);font-size:13px;display:block;}\n.lmv3 .badges{display:flex;gap:12px;flex-wrap:wrap;margin-top:14px;}\n.lmv3 .badges img{height:70px;border:1px solid var(--line);border-radius:8px;background:#fff;padding:4px;}\n\n\/* \u95e8\u5e97 *\/\n.lmv3 .stores{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:16px 0 4px;}\n.lmv3 .store-card{border:1px solid #e7ddc7;border-radius:14px;overflow:hidden;background:#fff;display:flex;flex-direction:column;box-shadow:0 2px 10px rgba(0,0,0,.04);}\n.lmv3 .store-card img{width:100%;height:208px;object-fit:cover;display:block;}\n.lmv3 .store-info{padding:16px 18px;}\n.lmv3 .store-info h3{margin:0 0 6px;font-size:18px;color:#1f2733;}\n.lmv3 .store-info .addr{margin:4px 0;font-size:13.5px;color:#555;line-height:1.5;}\n.lmv3 .store-info .tel{margin:6px 0 0;font-size:14.5px;font-weight:700;color:#c8a02a;}\n.lmv3 .store-info .tel a{color:#c8a02a;text-decoration:none;}\n\n\/* \u6a2a\u8bc4\u8868 *\/\n.lmv3 .cmp-table{width:100%;border-collapse:collapse;margin:14px 0;font-size:13.5px;background:#fff;box-shadow:0 2px 10px rgba(0,0,0,.04);}\n.lmv3 .cmp-table th,.lmv3 .cmp-table td{border:1px solid #ece3cf;padding:9px 11px;vertical-align:top;text-align:left;line-height:1.5;}\n.lmv3 .cmp-table thead th{background:linear-gradient(135deg,#23303f,#1f2733);color:#fff;font-weight:600;}\n.lmv3 .cmp-table tbody th{background:#f7f2e6;color:#23303f;font-weight:600;width:150px;}\n.lmv3 .cmp-table td.hitachi{background:#f1f8f1;font-weight:600;color:#1d6b3a;}\n.lmv3 .cmp-table tr:nth-child(even) td{background:#fcfaf4;}\n.lmv3 .cmp-table tr.hl th,.lmv3 .cmp-table tr.hl td{background:#fff4d6;font-weight:700;}\n.lmv3 .cmp-sub{font-size:15px;color:#23303f;margin:24px 0 6px;font-weight:700;border-left:4px solid #c8a02a;padding-left:10px;}\n.lmv3 .cmp-note{font-size:12.5px;color:#777;margin:6px 0 0;line-height:1.7;}\n.lmv3 .cmp-note-lg{font-size:14.5px;line-height:1.9;color:#2a2f38;margin:10px 0 0;}\n.lmv3 .rec{background:#f1f8f1;font-weight:700;color:#1d6b3a;}\n\n\/* FAQ *\/\n.lmv3 .faq{margin-top:8px;}\n.lmv3 .faq details{background:#faf7f1;border:1px solid var(--line);border-left:4px solid var(--red);\n  border-radius:8px;margin:12px 0;overflow:hidden;}\n.lmv3 .faq details summary{cursor:pointer;list-style:none;position:relative;padding:13px 42px 13px 16px;\n  font-size:14.5px;font-weight:600;color:var(--red);line-height:1.6;}\n.lmv3 .faq details summary::-webkit-details-marker{display:none;}\n.lmv3 .faq details summary::after{content:\"+\";position:absolute;right:16px;top:50%;transform:translateY(-50%);\n  font-size:20px;font-weight:700;color:var(--red);}\n.lmv3 .faq details[open] summary::after{content:\"\\2212\";}\n.lmv3 .faq details .a{padding:0 16px 14px;font-size:14px;color:#444;line-height:1.85;}\n\n\/* \u65b9\u6848\u4e66\u6027\u8d28\u8bf4\u660e *\/\n.lmv3 .remark{background:linear-gradient(135deg,#fff7e8,#fdf2da);border:1px solid var(--gold);\n  border-left:5px solid var(--gold);border-radius:10px;padding:16px 20px;margin:18px 0;font-size:13.5px;color:#4a3d20;line-height:1.85;}\n.lmv3 .remark b{color:#8a6a12;}\n.lmv3 .remark > b{display:block;margin-bottom:6px;font-size:14.5px;}\n.lmv3 .remark ol{margin:6px 0 0;padding-left:20px;}\n.lmv3 .remark li{margin:5px 0;}\n\n.lmv3 .toc{display:flex;flex-wrap:wrap;gap:8px;justify-content:center;margin:18px 0 2px;}\n.lmv3 .toc a{font-size:13px;color:#8a6a12;background:#fff;border:1px solid #e7ddc7;border-radius:20px;\n  padding:5px 14px;text-decoration:none;transition:all .2s;}\n.lmv3 .toc a:hover{background:#fdf2da;border-color:#c8a02a;color:#7a5c0a;}\n.lmv3 section{scroll-margin-top:16px;}\n.lmv3 .footnote{text-align:center;color:var(--gray);font-size:12px;padding:24px 12px 8px;line-height:1.8;}\n\n@media(max-width:760px){\n  .lmv3 .plans,.lmv3 .cards,.lmv3 .gallery,.lmv3 .vs{grid-template-columns:1fr;}\n  .lmv3 header.hero h1{font-size:24px;}\n  .lmv3 .cmp-table tbody th{width:auto;}\n  .lmv3 .stack-name{width:66px;font-size:12px;}\n  .lmv3 .stack-sum{width:74px;font-size:12px;}\n  .lmv3 .stack-bar span{font-size:0;}\n}\n@media(max-width:640px){\n  .lmv3 .stores{grid-template-columns:1fr;}\n}\n<\/style>\n\n<div class=\"lmv3\">\n\n<header class=\"hero\">\n  <div class=\"badge\">LONGMAI \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n  <h1>\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7<\/h1>\n  <p>\u65b9\u6848 A \u65e5\u7acb EX-\u8212\u4eab 125 \u00b7 \u4e00\u62d6\u56db\u3000|\u3000\u65b9\u6848 B \u65e5\u7acb VAM \u5c0a\u777f\u5168\u6548 125 \u00b7 \u4e09\u7ba1\u5236\u4e00\u62d6\u56db<\/p>\n  <div class=\"sub\">\u7a7a\u8c03\u53ea\u505a\u5236\u51b7\uff0c\u51ac\u5b63\u91c7\u6696\u4ea4\u7ed9\u5730\u6696 \u2014\u2014 \u4e00\u5957\u623f\u5b50\u4e24\u4ef6\u4e8b\uff0c\u5206\u5f00\u505a\u624d\u5404\u81ea\u5230\u4f4d<\/div>\n<\/header>\n\n<div class=\"wrap\">\n\n  <nav class=\"toc\" aria-label=\"\u672c\u518c\u76ee\u5f55\">\n    <a href=\"#s-info\">\u5ba2\u6237\u4fe1\u606f<\/a>\n    <a href=\"#s-req\">\u9700\u6c42\u8bca\u65ad<\/a>\n    <a href=\"#s-plan\">\u65b9\u6848\u603b\u89c8<\/a>\n    <a href=\"#s-cfg\">\u533a\u57df\u914d\u7f6e<\/a>\n    <a href=\"#s-split\">\u91c7\u6696\u5206\u5de5<\/a>\n    <a href=\"#s-floor\">\u5730\u6696\u63a5\u53e3<\/a>\n    <a href=\"#s-prod\">\u4ea7\u54c1\u5361\u724c<\/a>\n    <a href=\"#s-cmp\">\u54c1\u724c\u6a2a\u8bc4<\/a>\n    <a href=\"#s-quote\">\u62a5\u4ef7\u660e\u7ec6<\/a>\n    <a href=\"#s-adv\">\u9009\u8d2d\u5efa\u8bae<\/a>\n    <a href=\"#s-faq\">\u5e38\u89c1\u95ee\u9898<\/a>\n  <\/nav>\n\n  <section id=\"s-info\">\n    <h2 class=\"sec\">\u5ba2\u6237\u4fe1\u606f\u5361<\/h2>\n    <div class=\"kv\"><span>\u5ba2\u6237\u79f0\u547c<\/span><span>\u5411\u5973\u58eb<\/span><\/div>\n    <div class=\"kv\"><span>\u697c\u76d8 \/ \u6237\u578b<\/span><span>\u91d1\u8302\u6653\u68e0 \u00b7 \u5e73\u5c42\uff08\u5ba2\u9910\u5385\u53a8\u623f 52 \uff0b \u4e3b\u5367 16 \uff0b \u513f\u7ae5\u623f 8 \uff0b \u6b21\u5367 9\uff09<\/span><\/div>\n    <div class=\"kv\"><span>\u7a7a\u8c03\u8986\u76d6\u9762\u79ef<\/span><span>\u7ea6 85 \u33a1 \u00b7 4 \u4e2a\u7a7a\u8c03\u533a<\/span><\/div>\n    <div class=\"kv\"><span>\u4e3b\u673a<\/span><span>\u65e5\u7acb 125\uff0812.5kW\uff09\u00b7 \u4e00\u62d6\u56db<\/span><\/div>\n    <div class=\"kv\"><span>\u91c7\u6696\u9700\u6c42<\/span><span>\u6709 \u00b7 \u5730\u6696\uff08\u70ed\u6e90\u53e6\u9644\u65b9\u6848\uff09<\/span><\/div>\n    <div class=\"kv\"><span>\u672c\u6848\u987e\u95ee<\/span><span>\u4f59\u6653\u73b2 \u00b7 \u6696\u901a\u8bbe\u8ba1\u5e08 \u00b7 130-0811-3409<\/span><\/div>\n  <\/section>\n\n  <section id=\"s-req\">\n    <h2 class=\"sec\">\u9700\u6c42\u8bca\u65ad <small>\u60a8\u8bf4\u7684\u4e09\u6761\uff0c\u60a8\u6ca1\u8bf4\u7684\u4e09\u6761<\/small><\/h2>\n    <p class=\"lead\">\u60a8\u628a\u9700\u6c42\u8bf4\u5f97\u633a\u6e05\u695a\uff1a\u7a7a\u8c03\u53ea\u8981\u5236\u51b7\u6548\u679c\u597d\uff0c\u5bb6\u91cc\u8981\u505a\u5730\u6696\uff0c\u54c1\u724c\u770b\u7684\u662f\u65e5\u7acb\u3002\u8fd9\u4e09\u6761\u4e4b\u5916\uff0c\u8fd8\u6709\u4e09\u6761\u662f\u60a8\u5728\u804a\u5929\u91cc\u5e26\u51fa\u6765\u3001\u4f46\u6ca1\u5f53\u6210\u6761\u4ef6\u7684\u2014\u2014\u8282\u80fd\u3001\u5065\u5eb7\u8212\u9002\u3001\u6027\u4ef7\u6bd4\u3002\u6211\u4eec\u5bb6\u88c5\u65b9\u6848\uff0c\u663e\u6027\u8bc9\u6c42\u51b3\u5b9a\u914d\u7f6e\uff0c\u9690\u6027\u8bc9\u6c42\u51b3\u5b9a\u578b\u53f7\u3002\u4e0b\u9762\u628a\u516d\u6761\u5206\u5f00\u843d\u5730\u3002<\/p>\n    <table>\n      <thead><tr><th style=\"width:22%\">\u60a8\u7684\u8bc9\u6c42<\/th><th style=\"width:36%\">\u5bf9\u7a7a\u8c03\u610f\u5473\u7740\u4ec0\u4e48<\/th><th style=\"width:42%\">\u672c\u6848\u600e\u4e48\u505a<\/th><\/tr><\/thead>\n      <tbody>\n        <tr>\n          <td class=\"area\">\u5236\u51b7\u6548\u679c\u8981\u597d<\/td>\n          <td>\u6bcf\u4e2a\u623f\u95f4\u90fd\u8981\u51b7\u5f97\u4e0b\u6765\u3001\u51b7\u5f97\u5747\u5300\u3001\u4e0d\u76f4\u5439\u4eba\uff1b\u5ba2\u9910\u5385\u53a8\u623f\u8fde\u5728\u4e00\u8d77\uff0c\u8fd8\u8981\u89e3\u51b3\u6cb9\u70df\u533a\u7684\u56de\u98ce\u4f4d\u7f6e<\/td>\n          <td>\u6309 GB 50736-2012 \u9010\u623f\u914d\u51b7\u91cf\uff08\u5ba2\u9910\u5385\u53a8\u623f 137 W\/\u33a1\u3001\u4e3b\u5367 225\u3001\u513f\u7ae5\u623f 275\u3001\u6b21\u5367 244\uff09\uff0c\u8fde\u63a5\u7387 120.8%\uff0c\u5728\u6c1f\u673a 130% \u4e0a\u9650\u5185<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"area\">\u6709\u5730\u6696\u9700\u6c42<\/td>\n          <td>\u7a7a\u8c03\u4e0d\u5fc5\u4e3a\u201c\u51ac\u5b63\u5236\u70ed\u201d\u591a\u4ed8\u94b1\uff1a\u4e0d\u5fc5\u4e0a\u5927\u4e00\u53f7\u4e3b\u673a\uff0c\u4e5f\u4e0d\u5fc5\u9760\u7535\u8f85\u70ed\u786c\u625b<\/td>\n          <td>\u4e24\u65b9\u6848\u90fd\u6309<b>\u5236\u51b7\u4e3a\u4e3b<\/b>\u9009\u578b\uff1b\u51ac\u5b63\u91c7\u6696\u4ea4\u7ed9\u5730\u6696\u3002\u65b9\u6848\u4e8c\u989d\u5916\u9884\u7559\u6c34\u6a21\u5757\u63a5\u53e3\uff0c\u53ef\u505a\u5929\u6c1f\u5730\u6c34<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"area\">\u8ba4\u65e5\u7acb\u8fd9\u4e2a\u54c1\u724c<\/td>\n          <td>\u5728\u65e5\u7acb\u4f53\u7cfb\u5185\u6bd4\uff0c\u4e0d\u8de8\u54c1\u724c\u7ed5\u8def\uff0c\u628a\u9009\u62e9\u6536\u7a84\u6210\u201c\u54ea\u4e2a\u7cfb\u5217\u201d<\/td>\n          <td>\u4e24\u65b9\u6848\u540c\u4e3a\u65e5\u7acb 125 \u4e3b\u673a\u3001\u540c\u4e00\u5957\u5185\u673a\u51b7\u91cf\uff0c\u53ea\u5728\u7cfb\u5217\uff08\u8212\u4eab \/ \u5c0a\u777f\u5168\u6548\uff09\u4e0e\u51c0\u5316\u5c42\u7ea7\u4e0a\u62c9\u5f00\u5dee\u8ddd<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"area\">\u9690\u6027\uff1a\u8282\u80fd<\/td>\n          <td>\u4e0d\u662f\u770b\u4e00\u4e2a\u80fd\u6548\u6807\u7b7e\uff0c\u800c\u662f\u770b\u4e09\u4e94\u5e74\u540e\u7684\u7535\u8d39\u3001\u4ee5\u53ca\u6709\u6ca1\u6709\u4e3a\u7528\u4e0d\u4e0a\u7684\u80fd\u529b\u4ed8\u94b1<\/td>\n          <td>\u5168\u76f4\u6d41\u53d8\u9891 \uff0b 2000 \u7ea7\u7535\u5b50\u81a8\u80c0\u9600 \uff0b \u65e0\u7535\u8f85\u70ed\uff1b\u4e0d\u505a\u201c\u7a7a\u8c03\u4e5f\u5236\u70ed\u3001\u5730\u6696\u4e5f\u5236\u70ed\u201d\u7684\u53cc\u4efd\u80fd\u529b<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"area\">\u9690\u6027\uff1a\u5065\u5eb7\u8212\u9002<\/td>\n          <td>\u4e0d\u5439\u9709\u98ce\u3001\u4e0d\u5439\u5934\u3001\u6e7f\u5ea6\u522b\u5931\u63a7\uff1b\u5b69\u5b50\u623f\u95f4\u5c24\u5176\u5728\u610f<\/td>\n          <td>\u4e24\u65b9\u6848\u90fd\u6709\u81ea\u6e05\u6d01 \uff0b \u6c34\u6cf5\u6392\u6c61\u6c34 \uff0b \u6d6e\u5b50\u5f00\u5173\uff1b\u65b9\u6848\u4e00\u53ef\u9009\u914d PE \u51c0\u5316\u6a21\u5757\uff0c\u65b9\u6848\u4e8c\u51fa\u5382\u81ea\u5e26\u5168\u98ce\u8def\u51c0\u5316\u8231<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"area\">\u9690\u6027\uff1a\u6027\u4ef7\u6bd4<\/td>\n          <td>\u94b1\u82b1\u5728\u6bcf\u5929\u7528\u5f97\u5230\u7684\u5730\u65b9\uff0c\u4e5f\u4e3a\u5730\u6696\u7559\u51fa\u9884\u7b97<\/td>\n          <td>\u65b9\u6848\u4e00 26,861.60 \u8d77\u6b65\uff0c\u628a\u5dee\u4ef7\u7559\u7ed9\u5730\u6696\u4e0e\u8f6f\u88c5\uff1b\u65b9\u6848\u4e8c 41,530.40 \u7528\u4e00\u5957\u4e3b\u673a\u5e26\u4e24\u5957\u7cfb\u7edf<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"note\"><b>\u4e00\u53e5\u8bdd\u628a\u8bdd\u8bf4\u900f\uff1a<\/b>\u60a8\u8bf4\u201c\u7a7a\u8c03\u53ea\u89e3\u51b3\u5236\u51b7\u201d\uff0c\u8fd9\u53e5\u8bdd\u672c\u8eab\u5c31\u662f\u7701\u94b1\u7684\u5173\u952e\u3002\u4e2d\u592e\u7a7a\u8c03\u7684\u4ef7\u5dee\u5f88\u5927\u4e00\u90e8\u5206\u6765\u81ea\u201c\u80fd\u4e0d\u80fd\u5236\u70ed\u3001\u5236\u70ed\u5f3a\u4e0d\u5f3a\u201d\uff0c\u800c\u60a8\u5bb6\u51ac\u5929\u6709\u5730\u6696\uff0c\u8fd9\u90e8\u5206\u80fd\u529b\u5bf9\u60a8\u662f\u5907\u7528\u7684\u3002<b>\u4e0d\u4e3a\u5907\u7528\u80fd\u529b\u4ed8\u4e3b\u529b\u4ef7\u94b1<\/b>\uff0c\u662f\u8fd9\u4e2a\u65b9\u6848\u7684\u7b2c\u4e00\u6761\u539f\u5219\u3002<\/div>\n  <\/section>\n\n  <section id=\"s-plan\">\n    <h2 class=\"sec\">\u7cfb\u7edf\u67b6\u6784\u603b\u89c8 <small>\u4e24\u5957\u65b9\u6848\u5185\u673a\u51b7\u91cf\u5b8c\u5168\u4e00\u81f4\uff0c\u533a\u522b\u53ea\u5728\u7cfb\u5217\u3001\u51c0\u5316\u5c42\u7ea7\u4e0e\u5730\u6696\u63a5\u53e3<\/small><\/h2>\n    <div class=\"plans\">\n      <div class=\"plan a\">\n        <div class=\"ph\"><h3>\u65b9\u6848\u4e00 \u00b7 \u8212\u4eab 125<\/h3><div class=\"tag\">EX-\u8212\u4eab\u7cfb\u5217 \u00b7 \u5236\u51b7\u4e3a\u4e3b\u7684\u9ad8\u6027\u4ef7\u6bd4\u89e3<\/div><\/div>\n        <div class=\"pb\">\n          <div class=\"kv\"><span>\u9002\u7528\u533a\u57df<\/span><span>4 \u4e2a\u7a7a\u8c03\u533a\uff08\u5ba2\u9910\u5385\u53a8\u623f \uff0b \u4e3b\u5367 \uff0b \u513f\u7ae5\u623f \uff0b \u6b21\u5367\uff09<\/span><\/div>\n          <div class=\"kv\"><span>\u5916\u673a<\/span><span>RAS-125HRNAQ\uff08\u5355\u98ce\u6247 12.5kW\uff09<\/span><\/div>\n          <div class=\"kv\"><span>\u5185\u673a \u00d74<\/span><span>71 \/ 36 \/ 22 \/ 22 \u5404 1 \u53f0<\/span><\/div>\n          <div class=\"kv\"><span>\u8fde\u63a5\u7387<\/span><span>15.1 \/ 12.5 = 120.8%<\/span><\/div>\n          <div class=\"kv\"><span>\u5730\u6696\u63a5\u5165<\/span><span>\u53e6\u914d\u71c3\u6c14\u58c1\u6302\u7089\uff08\u72ec\u7acb\u91c7\u6696\u7cfb\u7edf\uff09<\/span><\/div>\n          <div class=\"kv\"><span>\u53c2\u8003\u4ef7<\/span><span><b>\uffe526,861.60<\/b><\/span><\/div>\n          <ul>\n            <li>\u5168\u76f4\u6d41\u53d8\u9891\uff0c\u8d85\u4e00\u7ea7\u80fd\u6548\uff08\u7cfb\u5217\u6700\u9ad8 APF 6.1\uff09<\/li>\n            <li>\u5ba4\u5185\u673a\u6700\u4f4e 17dB\uff0c\u5367\u5ba4\u591c\u95f4\u4e0d\u5435<\/li>\n            <li>\u00b10.5\u2103 \u6e29\u63a7\uff0c56 \u6863\u7cbe\u51c6\u9664\u6e7f<\/li>\n            <li>\u673a\u8eab\u539a 192mm\uff0c\u5c40\u90e8\u540a\u9876\u66f4\u7701\u5c42\u9ad8<\/li>\n            <li>\u5355\u98ce\u6247\u5916\u673a\u5360\u5730\u5c0f\uff0c\u9633\u53f0\u4f4d\u66f4\u597d\u5b89\u6392<\/li>\n          <\/ul>\n        <\/div>\n      <\/div>\n      <div class=\"plan b\">\n        <div class=\"ph\"><h3>\u65b9\u6848\u4e8c \u00b7 \u5c0a\u777f\u5168\u6548 125<\/h3><div class=\"tag\">VAM \u5c0a\u777f\u5168\u6548\u2161 \u00b7 \u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7<\/div><\/div>\n        <div class=\"pb\">\n          <div class=\"kv\"><span>\u9002\u7528\u533a\u57df<\/span><span>4 \u4e2a\u7a7a\u8c03\u533a\uff08\u540c\u4e0a\uff09<\/span><\/div>\n          <div class=\"kv\"><span>\u5916\u673a<\/span><span>RAS-125FSXPN5Q\uff0812.5kW\uff09<\/span><\/div>\n          <div class=\"kv\"><span>\u4e09\u7ba1\u5236\u5185\u673a \u00d74<\/span><span>71 \/ 36 \/ 22 \/ 22 \u5404 1 \u53f0<\/span><\/div>\n          <div class=\"kv\"><span>\u8fde\u63a5\u7387<\/span><span>15.1 \/ 12.5 = 120.8%<\/span><\/div>\n          <div class=\"kv\"><span>\u5730\u6696\u63a5\u5165<\/span><span>\u52a0\u88c5\u6c34\u6a21\u5757\u505a\u5929\u6c1f\u5730\u6c34\uff08\u4e00\u673a\u4e24\u7528\uff09<\/span><\/div>\n          <div class=\"kv\"><span>\u53c2\u8003\u4ef7<\/span><span><b>\uffe541,530.40<\/b><\/span><\/div>\n          <ul>\n            <li>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c18\u2103 \u4e0d\u964d\u6e29\u9664\u6e7f<\/li>\n            <li>\u5168\u98ce\u8def\u51c0\u5316\u8231\uff1aPE+ \u51c0\u5316\u3001\u81ea\u6e05\u6d01\u300160\u2103 \u9664\u83cc<\/li>\n            <li>\u8865\u6c14\u589e\u7113\uff0c\u51ac\u5b63\u4f4e\u6e29\u5236\u70ed\u80fd\u529b\u5f3a\uff08\u672c\u6848\u4f5c\u5907\u7528\uff09<\/li>\n            <li>\u53ef\u52a0\u6c34\u6a21\u5757\uff1a\u7a7a\u8c03 \uff0b \u5730\u6696\u4e00\u5957\u4e3b\u673a<\/li>\n            <li>\u5f69\u5c4f\u7ebf\u63a7\uff0c\u6e7f\u5ea6\u6570\u503c\u76f4\u63a5\u770b\u5f97\u89c1<\/li>\n          <\/ul>\n        <\/div>\n      <\/div>\n    <\/div>\n    <div class=\"note\">\u4e24\u65b9\u6848\u7684<b>\u5185\u673a\u51b7\u91cf\u5b8c\u5168\u76f8\u540c<\/b>\uff0871\/36\/22\/22\uff0c\u5408\u8ba1 15.1kW\uff09\uff0c\u4e3b\u673a\u540c\u4e3a 125\u3002\u5dee\u522b\u4e0d\u5728\u201c\u591f\u4e0d\u591f\u51b7\u201d\uff0c\u800c\u5728<b>\u9664\u6e7f\u65b9\u5f0f\u3001\u51c0\u5316\u5c42\u7ea7\u3001\u4ee5\u53ca\u5730\u6696\u70ed\u6e90\u600e\u4e48\u63a5<\/b>\u3002\u8fd9\u4e00\u70b9\u5f88\u91cd\u8981\uff1a\u60a8\u4e0d\u662f\u4e3a\u4e86\u201c\u66f4\u51b7\u201d\u591a\u82b1\u4e00\u4e07\u56db\uff0c\u800c\u662f\u4e3a\u4e86\u53e6\u5916\u4e09\u4ef6\u4e8b\u3002<\/div>\n  <\/section>\n\n  <section id=\"s-cfg\">\n    <h2 class=\"sec\">\u533a\u57df\u914d\u7f6e\u660e\u7ec6 <small>\u6309\u9762\u79ef\u9010\u623f\u914d\u51b7\u91cf\uff0c\u628a\u201c\u5927\u9a6c\u62c9\u5c0f\u8f66\u201d\u548c\u201c\u5c0f\u9a6c\u62c9\u5927\u8f66\u201d\u90fd\u907f\u5f00<\/small><\/h2>\n    <p class=\"lead\">\u8bbe\u8ba1\u4f9d\u636e GB 50736-2012\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b\uff0c\u4f4f\u5b85\u5236\u51b7\u8d1f\u8377\u6307\u6807 120\u2013220 W\/\u33a1\u3002\u4e0b\u8868\u201c\u914d\u7f6e\u8d1f\u8377\u201d\uff1d\u5185\u673a\u989d\u5b9a\u5236\u51b7\u91cf \u00f7 \u623f\u95f4\u9762\u79ef\uff0c\u662f\u8fd9\u53f0\u673a\u5668\u5728\u8be5\u623f\u95f4\u80fd\u63d0\u4f9b\u7684\u4e0a\u9650\u3002<\/p>\n    <table>\n      <thead>\n        <tr><th>\u533a\u57df<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a<br>\uff08\u8212\u4eab \/ \u5c0a\u777f\u540c\uff09<\/th><th>\u5355\u53f0\u51b7\u91cf<\/th><th>\u914d\u7f6e\u8d1f\u8377<br>(W\/\u33a1)<\/th><th>\u914d\u7f6e\u8bf4\u660e<\/th><\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"area\">\u5ba2\u9910\u5385 \uff0b \u53a8\u623f<\/td><td>52 \u33a1<\/td><td>71 \u578b<\/td><td>7,100 W<\/td><td>137<\/td><td class=\"tl\">\u5ba2\u9910\u53a8\u4e00\u4f53\u7684\u5f00\u653e\u7a7a\u95f4\uff0c71 \u578b\u5355\u53f0\u8986\u76d6\uff1b\u56de\u98ce\u53e3\u907f\u5f00\u7076\u53f0\u6b63\u4e0a\u65b9\uff0c\u9632\u6cb9\u70df\u5012\u704c<\/td><\/tr>\n        <tr><td class=\"area\">\u4e3b\u5367<\/td><td>16 \u33a1<\/td><td>36 \u578b<\/td><td>3,600 W<\/td><td>225<\/td><td class=\"tl\">16\u33a1 \u5e38\u7528 28 \u6216 36 \u578b\uff1b36 \u578b\u6bd4 28 \u578b\u8bbe\u5907\u4ef7\u53ea\u9ad8 40 \u5143\uff0c\u4f59\u91cf\u5374\u591a 0.8kW\uff0c\u53d6 36 \u578b<\/td><\/tr>\n        <tr><td class=\"area\">\u513f\u7ae5\u623f<\/td><td>8 \u33a1<\/td><td>22 \u578b<\/td><td>2,200 W<\/td><td>275<\/td><td class=\"tl\">22 \u578b\u662f\u65e5\u7acb\u4e00\u62d6\u591a\u7684\u6700\u5c0f\u6807\u51c6\u5185\u673a\uff0c\u65e0\u66f4\u5c0f\u53ef\u9009\uff1b\u9760\u53d8\u9891\u964d\u8d1f\u8377\u6d88\u5316<\/td><\/tr>\n        <tr><td class=\"area\">\u6b21\u5367<\/td><td>9 \u33a1<\/td><td>22 \u578b<\/td><td>2,200 W<\/td><td>244<\/td><td class=\"tl\">\u4e0e\u513f\u7ae5\u623f\u540c\u89c4\u683c\uff0c\u65e5\u540e\u5907\u4ef6\u3001\u6ee4\u7f51\u901a\u7528<\/td><\/tr>\n        <tr><td class=\"area\">\u5916\u673a<\/td><td colspan=\"5\" class=\"tl\">\n          \u65b9\u6848\u4e00 RAS-125HRNAQ \uff0f \u65b9\u6848\u4e8c RAS-125FSXPN5Q\uff08\u5747 12.5kW\uff09<br>\n          \u5185\u673a\u603b\u80fd\u529b 7.1 \uff0b 3.6 \uff0b 2.2 \uff0b 2.2 \uff1d <b>15.1 kW<\/b> \uff5c \u8fde\u63a5\u7387 \uff1d 15.1 \u00f7 12.5 \uff1d <b>120.8%<\/b>\uff08\u6c1f\u673a \u2264130% \u5408\u89c4\uff09\n        <\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"note\">\n      <b>\u4e09\u5904\u8981\u5982\u5b9e\u4ea4\u4ee3\u7684\u5730\u65b9\uff1a<\/b><br>\n      \u2460 <b>\u4e3b\u5367 225 W\/\u33a1<\/b> \u7565\u9ad8\u4e8e 220 \u7684\u901a\u7528\u4e0a\u9650\u7ea6 2%\u3002\u539f\u56e0\u662f 36 \u578b\u4e0e 28 \u578b\u8bbe\u5907\u4ef7\u53ea\u5dee 40 \u5143\u3001\u5b89\u88c5\u8d39\u76f8\u540c\uff0c\u800c 36 \u578b\u591a 0.8kW \u4f59\u91cf\u3002\u5982\u679c\u4e3b\u5367\u662f\u897f\u6652\u9762\u6216\u5927\u98d8\u7a97\uff0c\u8fd9 0.8kW \u5c31\u662f\u590f\u5929\u5348\u540e\u80fd\u4e0d\u80fd\u538b\u4f4f\u7684\u5173\u952e\uff1b\u5982\u679c\u4e0d\u662f\uff0c28 \u578b\u4e5f\u5728\u533a\u95f4\u5185\uff0c\u53ef\u4ee5\u73b0\u573a\u590d\u5c3a\u540e\u518d\u5b9a\u3002<br>\n      \u2461 <b>\u513f\u7ae5\u623f 275\u3001\u6b21\u5367 244 W\/\u33a1<\/b> \u9ad8\u4e8e\u533a\u95f4\u4e0a\u9650\uff0c\u4f46\u8fd9\u4e0d\u662f\u201c\u914d\u5927\u4e86\u201d\uff0c\u662f<b>\u6ca1\u6709\u66f4\u5c0f\u7684\u673a\u5668<\/b>\u30028\u20139\u33a1 \u6309 220 W\/\u33a1 \u53ea\u9700 1.76\u20131.98kW\uff0c\u800c\u65e5\u7acb\u4e00\u62d6\u591a\u6700\u5c0f\u6807\u51c6\u5185\u673a\u5c31\u662f 22 \u578b\uff082.2kW\uff09\u3002\u5b9e\u9645\u4f7f\u7528\u4e2d\u623f\u95f4\u5230\u6e29\u540e\u4e3b\u673a\u4f1a\u964d\u9891\u3001\u5185\u673a\u81a8\u80c0\u9600\u6536\u5c0f\uff0c\u8f93\u51fa\u8fdc\u4f4e\u4e8e\u989d\u5b9a\u503c\uff0c\u4e0d\u5b58\u5728\u201c\u51bb\u4eba\u201d\u7684\u95ee\u9898\u3002<br>\n      \u2462 <b>\u8fde\u63a5\u7387 120.8%<\/b> \u610f\u5473\u7740\u56db\u53f0\u5168\u5f00\u6ee1\u8d1f\u8377\u65f6\uff0c\u4e3b\u673a\u80fd\u529b\u7565\u5c0f\u4e8e\u5185\u673a\u6807\u79f0\u4e4b\u548c\u3002\u8fd9\u662f\u884c\u4e1a\u5e38\u89c4\u505a\u6cd5\uff0890%\u2013130% \u533a\u95f4\uff09\uff0c\u524d\u63d0\u662f\u5404\u623f\u95f4\u4e0d\u540c\u65f6\u6ee1\u8f7d\u2014\u2014\u767d\u5929\u5ba2\u5385\u4e3a\u4e3b\u3001\u591c\u95f4\u5367\u5ba4\u4e3a\u4e3b\u3002\u82e5\u590f\u5929\u508d\u665a\u56db\u53f0\u540c\u65f6\u5f00\u4e14\u90fd\u8bbe\u5f88\u4f4e\u6e29\u5ea6\uff0c\u964d\u6e29\u4f1a\u6162\u4e00\u4e9b\uff0c\u4f46\u4e0d\u4f1a\u505c\u673a\u3002\n    <\/div>\n  <\/section>\n\n  <section id=\"s-split\">\n    <h2 class=\"sec\">\u91c7\u6696\u5206\u5de5 <small>\u4e3a\u4ec0\u4e48\u8fd9\u5957\u623f\u5b50\uff0c\u51ac\u5929\u4e0d\u5efa\u8bae\u8ba9\u7a7a\u8c03\u625b<\/small><\/h2>\n    <p class=\"lead\">\u60a8\u8bf4\u201c\u7a7a\u8c03\u53ea\u89e3\u51b3\u5236\u51b7\u6548\u679c\u597d\u201d\uff0c\u8fd9\u53e5\u8bdd\u5728\u6210\u90fd\u7279\u522b\u5bf9\u3002\u4e0d\u662f\u7a7a\u8c03\u4e0d\u80fd\u5236\u70ed\uff0c\u800c\u662f<b>\u7528\u7a7a\u8c03\u8fc7\u51ac\uff0c\u8981\u4e3a\u4e00\u4ef6\u5b83\u4e0d\u64c5\u957f\u7684\u4e8b\u4ed8\u94b1\uff0c\u8fd8\u5f97\u63a5\u53d7\u5b83\u505a\u4e0d\u5230\u7684\u4f53\u611f<\/b>\u3002\u4e09\u4e2a\u7269\u7406\u5c42\u9762\u7684\u539f\u56e0\uff0c\u8ddf\u54c1\u724c\u65e0\u5173\u3002<\/p>\n    <table>\n      <thead><tr><th style=\"width:20%\">\u73b0\u8c61<\/th><th style=\"width:40%\">\u4e3a\u4ec0\u4e48\u4f1a\u8fd9\u6837<\/th><th style=\"width:40%\">\u4f4f\u8fdb\u53bb\u7684\u611f\u53d7<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><td class=\"area\">\u5934\u70ed\u811a\u51b7<\/td><td class=\"tl\">\u70ed\u7a7a\u6c14\u5bc6\u5ea6\u5c0f\u4f1a\u5f80\u4e0a\u6d6e\uff0c\u7a7a\u8c03\u9001\u51fa\u7684\u70ed\u98ce\u5230\u4e0d\u4e86\u5730\u9762 30cm \u4ee5\u5185<\/td><td class=\"tl\">\u8138\u53d1\u70eb\u3001\u811a\u51b0\u51c9\uff0c\u5b69\u5b50\u5728\u5730\u57ab\u4e0a\u73a9\u8981\u989d\u5916\u5f00\u53d6\u6696\u5668<\/td><\/tr>\n        <tr><td class=\"area\">\u5316\u971c\u505c\u673a<\/td><td class=\"tl\">\u5ba4\u5916\u673a\u5728\u4f4e\u6e29\u9ad8\u6e7f\u65f6\u7ed3\u971c\uff0c\u673a\u7ec4\u8981\u53cd\u5411\u8fd0\u884c\u5316\u971c\uff0c\u5316\u971c\u671f\u95f4\u5ba4\u5185\u505c\u6b62\u9001\u70ed\u98ce<\/td><td class=\"tl\">\u6210\u90fd\u6e7f\u51b7\u5929\u5c24\u5176\u660e\u663e\uff0c\u6bcf\u9694\u4e00\u6bb5\u65f6\u95f4\u5ba4\u5185\u4f1a\u201c\u51c9\u4e00\u4e0b\u201d<\/td><\/tr>\n        <tr><td class=\"area\">\u4f4e\u6e29\u8870\u51cf<\/td><td class=\"tl\">\u5ba4\u5916\u6e29\u5ea6\u8d8a\u4f4e\uff0c\u53ef\u642c\u8fd0\u7684\u70ed\u91cf\u8d8a\u5c11\uff0c\u5236\u70ed\u91cf\u968f\u4e4b\u4e0b\u6ed1\uff0c\u90e8\u5206\u673a\u578b\u9760\u7535\u8f85\u70ed\u8865<\/td><td class=\"tl\">\u6700\u51b7\u7684\u90a3\u51e0\u5929\u6070\u597d\u662f\u80fd\u529b\u6700\u5f31\u7684\u65f6\u5019\uff0c\u7535\u8d39\u4e5f\u6700\u9ad8<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <p class=\"cmp-note-lg\"><b>\u5730\u6696\u4e3a\u4ec0\u4e48\u5408\u9002\uff1a<\/b>\u5730\u6696\u8d70 35\u201345\u2103 \u7684\u4f4e\u6e29\u70ed\u6c34\uff0c\u70ed\u91cf\u4ece\u5730\u9762\u5411\u4e0a\u8f90\u5c04\uff0c\u5730\u9762\u6e29\u5ea6 28\u201332\u2103\uff0c\u5f62\u6210\u201c\u811a\u6696\u5934\u51c9\u201d\u7684\u6e29\u5ea6\u5206\u5e03\u2014\u2014\u8fd9\u6070\u597d\u7b26\u5408\u4eba\u4f53\u8212\u9002\u533a\u7684\u5206\u5e03\u3002\u5b83\u6ca1\u6709\u5439\u98ce\u611f\uff0c\u4e0d\u626c\u5c18\uff0c\u4e0d\u6270\u52a8\u7a7a\u6c14\uff0c\u5bf9\u5b69\u5b50\u7684\u547c\u5438\u9053\u66f4\u53cb\u597d\u3002\u800c\u4e14\u6c34\u6e29\u4f4e\u610f\u5473\u7740\u70ed\u6e90\u4e0d\u9700\u8981\u70e7\u5230\u5f88\u9ad8\u6e29\u5ea6\uff0c<b>\u5355\u4f4d\u70ed\u91cf\u7684\u80fd\u8017\u66f4\u4f4e<\/b>\u3002<\/p>\n    <div class=\"note\">\n      <b>\u6240\u4ee5\u672c\u6848\u7684\u5206\u5de5\u662f\uff1a<\/b>\u7a7a\u8c03\u8d1f\u8d23 6\u20139 \u6708\u7684\u5236\u51b7\uff08\u7ea6 3 \u4e2a\u6708\uff09\uff0c\u5730\u6696\u8d1f\u8d23 12\u20132 \u6708\u7684\u91c7\u6696\uff08\u7ea6 3 \u4e2a\u6708\uff09\uff0c\u6625\u79cb\u8fc7\u6e21\u5b63\u5076\u5c14\u964d\u6e29\u65f6\uff0c\u7a7a\u8c03\u77ed\u65f6\u7528\u4e00\u4e0b\u3002<br>\n      \u76f8\u5e94\u5730\uff0c\u4e24\u4e2a\u65b9\u6848\u90fd<b>\u6ca1\u6709\u4e3a\u201c\u5f3a\u70ed\u201d\u591a\u4ed8\u94b1<\/b>\uff1a\u4e3b\u673a\u90fd\u662f 125\uff0c\u4e0d\u56e0\u91c7\u6696\u9700\u6c42\u5f80\u4e0a\u52a0\u6863\u3002\u65b9\u6848\u4e8c\u7684\u8865\u6c14\u589e\u7113\u5f3a\u70ed\u80fd\u529b\u4fdd\u7559\u7740\uff0c\u4f46\u5b83\u662f\u201c\u8fc7\u6e21\u5b63\u548c\u6781\u7aef\u5929\u6c14\u7684\u5907\u7528\u201d\uff0c\u4e0d\u662f\u60a8\u5bb6\u7684\u4e3b\u529b\u91c7\u6696\u65b9\u5f0f\u3002\n    <\/div>\n  <\/section>\n\n  <section id=\"s-floor\">\n    <h2 class=\"sec\">\u5730\u6696\u63a5\u53e3 <small>\u540c\u4e00\u5957\u5730\u6696\uff0c\u70ed\u6e90\u4e0d\u540c\uff0c\u957f\u671f\u8d26\u4e0d\u540c<\/small><\/h2>\n    <p class=\"lead\">\u5730\u6696\u672c\u8eab\uff08\u76d8\u7ba1\u3001\u4fdd\u6e29\u3001\u56de\u586b\u3001\u5206\u96c6\u6c34\u5668\u3001\u63a7\u5236\uff09\u4e24\u79cd\u65b9\u6848\u90fd\u4e00\u6837\u505a\uff0c\u672c\u518c\u4e0d\u5c55\u5f00\uff0c\u4f1a\u5355\u72ec\u51fa\u4e00\u4efd\u5730\u6696\u65b9\u6848\u4e0e\u62a5\u4ef7\u3002\u8fd9\u91cc\u53ea\u8bf4\u4e00\u4ef6\u4e8b\uff1a<b>\u70ed\u6e90\u600e\u4e48\u63a5<\/b>\uff0c\u56e0\u4e3a\u8fd9\u76f4\u63a5\u51b3\u5b9a\u4e86\u60a8\u73b0\u5728\u8be5\u9009\u54ea\u53f0\u4e3b\u673a\u3002<\/p>\n    <table class=\"cmp-table\">\n      <thead><tr><th style=\"width:20%\">\u5bf9\u6bd4\u9879<\/th><th style=\"width:40%\">\u65b9\u6848\u4e00 \u00b7 \u8212\u4eab \uff0b \u71c3\u6c14\u58c1\u6302\u7089<\/th><th style=\"width:40%\">\u65b9\u6848\u4e8c \u00b7 \u5c0a\u777f\u5168\u6548 \uff0b \u6c34\u6a21\u5757\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u7cfb\u7edf\u6570\u91cf<\/th><td>2 \u5957\uff1a\u7a7a\u8c03\u4e00\u5957\u3001\u91c7\u6696\u4e00\u5957\uff0c\u5404\u8d70\u5404\u7684\u7ba1\u8def<\/td><td class=\"hitachi\">1 \u5957\u4e3b\u673a \uff0b \u6c34\u6a21\u5757\uff1a\u7a7a\u8c03\u4e0e\u5730\u6696\u5171\u7528\u4e00\u4e2a\u51b7\u5a92\u7cfb\u7edf<\/td><\/tr>\n        <tr><th>\u8bbe\u5907\u4f4d\u7f6e<\/th><td>\u8981\u9505\u7089\u4f4d\u3001\u70df\u9053\u5b54\u3001\u71c3\u6c14\u63a5\u53e3\uff0c\u901a\u5e38\u5360\u53a8\u623f\u6216\u751f\u6d3b\u9633\u53f0\u4e00\u4e2a\u67dc\u4f4d<\/td><td class=\"hitachi\">\u4e0d\u8981\u9505\u7089\u3001\u4e0d\u8981\u70df\u9053\uff0c\u5916\u673a\u4fa7\u52a0\u6c34\u6a21\u5757\uff0c\u5ba4\u5185\u66f4\u6574\u6d01<\/td><\/tr>\n        <tr><th>\u70ed\u6e90\u6027\u8d28<\/th><td>\u71c3\u6c14\u51b7\u51dd\u7089\uff0c\u70e7\u6c14\u53d6\u6696<\/td><td class=\"hitachi\">\u6c1f\u6c34\u6362\u70ed\u5668\uff0c\u9760\u70ed\u6cf5\u642c\u8fd0\u7a7a\u6c14\u4e2d\u7684\u70ed\u91cf\uff0c\u7528\u7535<\/td><\/tr>\n        <tr><th>\u5e74\u5ea6\u7ef4\u62a4<\/th><td>\u71c3\u70e7\u5ba4\u3001\u677f\u6362\u3001\u51b7\u51dd\u6c34\u76d8<b>\u6bcf\u5e74\u6e05\u6d17<\/b>\uff0c\u4e0d\u6d17\u6548\u7387\u9010\u5e74\u4e0b\u964d\uff08\u7ea6 800 \u5143\/\u5e74\uff09<\/td><td class=\"hitachi\">\u6c34\u4fa7\u4e3a\u5c01\u95ed\u56de\u8def\u4f4e\u6e29\u6362\u70ed\uff0c<b>\u4e0d\u7ed3\u57a2\u3001\u514d\u6e05\u6d17\u677f\u6362<\/b>\uff08\u7ea6 300 \u5143\/\u5e74\uff09<\/td><\/tr>\n        <tr><th>\u70ed\u6e90\u5bff\u547d<\/th><td>\u71c3\u6c14\u9505\u7089\u6309\u56fd\u5bb6\u5224\u5e9f\u6807\u51c6\uff0c<b>7\u20138 \u5e74<\/b>\u9700\u66f4\u6362<\/td><td class=\"hitachi\">\u6362\u70ed\u6a21\u5757\u8bbe\u8ba1\u5bff\u547d <b>20 \u5e74<\/b>\uff0c\u4e0e\u7a7a\u8c03\u4e3b\u673a\u540c\u5468\u671f<\/td><\/tr>\n        <tr><th>\u6545\u969c\u70b9<\/th><td>\u4e24\u5957\u7cfb\u7edf\u4e24\u5957\u6545\u969c\u70b9\uff0c\u4efb\u4e00\u5957\u51fa\u95ee\u9898\u5404\u4fee\u5404\u7684<\/td><td class=\"hitachi\">\u4e00\u5957\u7cfb\u7edf\uff0c\u8054\u52a8\u63a7\u5236\uff0c\u51ac\u5b63\u5207\u6362\u7531\u9762\u677f\u5b8c\u6210<\/td><\/tr>\n        <tr><th>\u521d\u6295<\/th><td>\u7a7a\u8c03 26,861.60 \uff0b \u9505\u7089\u4e0e\u5730\u6696\uff08\u53e6\u9644\uff09<\/td><td>\u7a7a\u8c03 41,530.40 \uff0b \u6c34\u6a21\u5757\u4e0e\u5730\u6696\uff08\u53e6\u9644\uff09<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <div class=\"note\">\n      <b>\u8d26\u8981\u8fd9\u4e48\u7b97\uff1a<\/b>\u9505\u7089 7\u20138 \u5e74\u4e00\u6362\u3001\u6bcf\u5e74 800 \u5143\u6e05\u6d17\uff0c20 \u5e74\u4e0b\u6765\u662f\u4e24\u5230\u4e09\u6b21\u66f4\u6362\u52a0\u4e00\u4e07\u516d\u5343\u5143\u7ef4\u62a4\uff1b\u6c34\u6a21\u5757 20 \u5e74\u514d\u66f4\u6362\u3001\u7ef4\u62a4\u7ea6 300 \u5143\/\u5e74\u3002\u65b9\u6848\u4e8c\u521d\u671f\u6295\u5165\u9ad8\uff0c\u4f46\u628a\u5468\u671f\u62c9\u957f\u770b\uff0c\u70ed\u6e90\u8fd9\u5757\u7684\u91cd\u590d\u6295\u5165\u5c11\u4e00\u6b21\u5230\u4e24\u6b21\u3002<b>\u53cd\u8fc7\u6765\u8bf4\uff0c\u5982\u679c\u60a8\u6253\u7b97 5 \u5e74\u5185\u6362\u623f\uff0c\u6216\u8005\u66f4\u770b\u91cd\u5f53\u4e0b\u73b0\u91d1\u6d41\uff0c\u65b9\u6848\u4e00\u628a\u94b1\u82b1\u5728\u7a7a\u8c03\u4e0a\u3001\u5730\u6696\u70ed\u6e90\u4ee5\u540e\u518d\u8bf4\uff0c\u4e5f\u5b8c\u5168\u6210\u7acb\u3002<\/b>\u4e24\u79cd\u9009\u62e9\u90fd\u5408\u7406\uff0c\u53d6\u51b3\u4e8e\u60a8\u600e\u4e48\u770b\u8fd9\u7b14\u65f6\u95f4\u8d26\u3002\n    <\/div>\n    <div class=\"note\">\n      <b>A \u4e0e B \u90fd\u4e0d\u80fd\u62d6\u7684\u4e00\u4ef6\u4e8b\uff1a<\/b>\u5730\u6696\u76d8\u7ba1\u3001\u4fdd\u6e29\u5c42\u3001\u5206\u96c6\u6c34\u5668\u548c\u4e3b\u7ba1<b>\u5fc5\u987b\u4e0e\u88c5\u4fee\u540c\u6b65\u505a<\/b>\u2014\u2014\u76d8\u7ba1\u57cb\u5728\u627e\u5e73\u5c42\u91cc\uff0c\u88c5\u4fee\u5b8c\u518d\u52a0\u5c31\u8981\u62c6\u5730\u9762\u3002\u70ed\u6e90\u53ef\u4ee5\u540e\u5b9a\uff0c\u4f46\u63a5\u53e3\u8981\u73b0\u5728\u7559\uff1a<br>\n      \u00b7 \u9009\u65b9\u6848\u4e00 \u2192 \u73b0\u5728\u9884\u7559\u9505\u7089\u4f4d\u3001\u70df\u9053\u5b54\u3001\u71c3\u6c14\u63a5\u53e3\uff1b<br>\n      \u00b7 \u9009\u65b9\u6848\u4e8c \u2192 \u73b0\u5728\u5c31\u8981\u5b9a\u5c0a\u777f\u5168\u6548\u4e3b\u673a\uff0c\u5e76\u5728\u5916\u673a\u4fa7\u9884\u7559\u6c34\u6a21\u5757\u5b89\u88c5\u4f4d\u4e0e\u51b7\u5a92\u7ba1\u63a5\u53e3\uff08\u6c34\u6a21\u5757\u5fc5\u987b\u4e0e\u4e3b\u673a\u540c\u4e00\u51b7\u5a92\u7cfb\u7edf\uff0c\u4e8b\u540e\u52a0\u88c5\u7b49\u4e8e\u91cd\u505a\u7ba1\u8def\uff09\u3002<br>\n      \u8fd9\u5c31\u662f\u4e3a\u4ec0\u4e48\u201c\u5148\u88c5\u7a7a\u8c03\u3001\u8fc7\u4e24\u5e74\u518d\u52a0\u5730\u6696\u201d\u8fd9\u53e5\u8bdd\uff0c\u5b9e\u9645\u51b3\u7b56\u70b9\u5728<b>\u4eca\u5929\u9009\u54ea\u53f0\u4e3b\u673a<\/b>\u3002\n    <\/div>\n  <\/section>\n\n  <section id=\"s-prod\">\n    <h2 class=\"sec\">\u6838\u5fc3\u4ea7\u54c1\u5361\u724c <small>\u9f20\u6807\u60ac\u505c\u6216\u70b9\u51fb\u7ffb\u8f6c\u770b\u5356\u70b9<\/small><\/h2>\n    <p class=\"lead\">\u672c\u6848\u6d89\u53ca\u56db\u7c7b\u786c\u4ef6\u3001\u4e00\u79cd\u91c7\u6696\u6269\u5c55\u4ef6\u3001\u4e24\u79cd\u7ebf\u63a7\u5668\u3002\u56fe\u7247\u53d6\u81ea\u9f99\u8109\u4ea7\u54c1\u5e93\u5143\u6570\u636e\uff0c\u5747\u4e3a\u5728\u552e\u673a\u578b\u3002<\/p>\n    <div class=\"cards\">\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-sx-dfs-112160.jpg\" alt=\"\u65e5\u7acb\u8212\u4eab125\u5355\u98ce\u6247\u5916\u673a\">\n            <div class=\"cap\">\u8212\u4eab 125 \u5355\u98ce\u6247\u5916\u673a<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>EX-\u8212\u4eab \u00b7 \u6838\u5fc3\u5356\u70b9\uff08\u65b9\u6848\u4e00\uff09<\/h4>\n            <ul>\n              <li>\u5168\u76f4\u6d41\u53d8\u9891\uff0c\u8d85\u4e00\u7ea7\u80fd\u6548\uff08\u7cfb\u5217\u6700\u9ad8 APF 6.1\uff09<\/li>\n              <li>\u5ba4\u5185\u673a\u6700\u4f4e 17dB\uff0c\u591c\u95f4\u9759\u97f3\u518d\u964d 9dB<\/li>\n              <li>\u00b10.5\u2103 \u6e29\u63a7\uff0c56 \u6863\u7cbe\u7ec6\u9664\u6e7f<\/li>\n              <li>\u5355\u98ce\u6247\u5916\u673a\u5360\u5730\u5c0f\uff0c\u9633\u53f0\u4f4d\u597d\u5b89\u6392<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-nj-cb.jpg\" alt=\"\u65e5\u7acb\u8212\u4eab\u8d85\u8584\u5185\u673a\">\n            <div class=\"cap\">\u8212\u4eab\u8d85\u8584\u5185\u673a\uff0822\/36\/71\uff09<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>\u8d85\u8584\u5185\u673a \u00b7 \u6838\u5fc3\u5356\u70b9<\/h4>\n            <ul>\n              <li>\u673a\u8eab\u539a 192mm\uff0c\u5c40\u90e8\u540a\u9876\u66f4\u7701\u5c42\u9ad8<\/li>\n              <li>\u6700\u4f4e 17dB\uff0c\u56db\u7ef4\u534f\u540c\u964d\u566a<\/li>\n              <li>\u4e8c\u6b21\u7ed3\u51b0\u81ea\u6e05\u6d01 \uff0b \u6c34\u6cf5\u6392\u6c61\u6c34\uff0c\u673a\u5185\u4e0d\u85cf\u9709<\/li>\n              <li>\u6807\u914d WiFi \u7ebf\u63a7\uff0c\u65e5\u7acb\u667a\u5bb6 APP \u4e92\u8054<\/li>\n              <li>\u56de\u98ce\u53e3\u53ef\u9009\u914d PE \u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-zrqx.jpg\" alt=\"\u65e5\u7acb\u5c0a\u777f\u5168\u6548125\u5916\u673a\">\n            <div class=\"cap\">\u5c0a\u777f\u5168\u6548 125 \u5916\u673a<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>VAM \u5c0a\u777f\u5168\u6548\u2161 \u00b7 \u6838\u5fc3\u5356\u70b9\uff08\u65b9\u6848\u4e8c\uff09<\/h4>\n            <ul>\n              <li>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c18\u2103 \u4e0d\u964d\u6e29\u9664\u6e7f<\/li>\n              <li>\u5168\u98ce\u8def\u51c0\u5316\u8231\uff1aPE+ \u51c0\u5316\u3001\u81ea\u6e05\u6d01\u300160\u2103 \u9664\u83cc<\/li>\n              <li>\u8865\u6c14\u589e\u7113\uff0c\u51ac\u5b63\u4f4e\u6e29\u5236\u70ed\u80fd\u529b\u5f3a\uff08\u672c\u6848\u4f5c\u5907\u7528\uff09<\/li>\n              <li>\u53ef\u52a0\u6c34\u6a21\u5757\uff0c\u7a7a\u8c03 \uff0b \u5730\u6696\u4e00\u5957\u4e3b\u673a<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-nj-wssksgz.jpg\" alt=\"\u65e5\u7acb\u5c0a\u777f\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u673a\">\n            <div class=\"cap\">\u5c0a\u777f\u4e09\u7ba1\u5236\u5185\u673a\uff0822\/36\/71\uff09<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\u5185\u673a \u00b7 \u5356\u70b9<\/h4>\n            <ul>\n              <li>\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\uff0c\u9664\u6e7f\u4e0d\u964d\u6e29<\/li>\n              <li>\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0c\u4ece\u51fa\u98ce\u53e3\u5c31\u5f00\u59cb\u51c0<\/li>\n              <li>\u6700\u4f4e 17dB\uff0c\u9759\u97f3\u8fd0\u884c<\/li>\n              <li>\u4e0e\u5c0a\u777f\u5168\u6548 125 \u4e3b\u673a\u5339\u914d\uff0c\u53ef\u63a5\u6c34\u6a21\u5757<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-zrqx-smk.jpg\" alt=\"\u5c0a\u777f\u5168\u6548\u6c34\u6a21\u5757\">\n            <div class=\"cap\">\u5c0a\u777f\u5168\u6548\u6c34\u6a21\u5757\uff08\u65b9\u6848\u4e8c\u9009\u914d\uff09<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>\u6c34\u6a21\u5757 \u00b7 \u5356\u70b9\uff08\u672c\u6848\u6709\u5730\u6696\u9700\u6c42\uff09<\/h4>\n            <ul>\n              <li>\u6c1f\u6c34\u6362\u70ed\u5668\uff1a\u5236\u51b7\u5242\u4e0e\u6c34\u5728\u5c01\u95ed\u56de\u8def\u4f4e\u6e29\u6362\u70ed<\/li>\n              <li>\u6c34\u4fa7\u5c01\u95ed\u5faa\u73af\uff0c<b>\u4e0d\u7ed3\u57a2\u3001\u514d\u6e05\u6d17\u677f\u6362<\/b>\u3001\u65e0\u9700\u6c34\u8d28\u5904\u7406<\/li>\n              <li>\u6362\u70ed\u6a21\u5757\u8bbe\u8ba1\u5bff\u547d 20 \u5e74\uff0c\u4e0e\u4e3b\u673a\u540c\u5468\u671f<\/li>\n              <li>\u63a5\u4e0a\u5730\u6696\u5373\u53ef\u4e00\u673a\u4e24\u7528\uff1a\u590f\u5b63\u5236\u51b7\u3001\u51ac\u5b63\u91c7\u6696<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-pj-kzq-wifi-xkq.jpg\" alt=\"\u65e5\u7acbWiFi\u7ebf\u63a7\u5668\">\n            <div class=\"cap\">WiFi \u7ebf\u63a7\u5668\uff08\u65b9\u6848\u4e00 \u00b7 \u8212\u4eab\uff09<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>WiFi \u7ebf\u63a7\u5668 \u00b7 \u5356\u70b9<\/h4>\n            <ul>\n              <li>\u578b\u53f7 PC-P1HVQA\uff0c\u6bcf\u53f0\u5185\u673a\u914d 1 \u4e2a<\/li>\n              <li>\u65e5\u7acb\u667a\u5bb6 APP \u4e92\u8054\uff0c\u8fdc\u7a0b\u5f00\u5173 \/ \u8c03\u6e29<\/li>\n              <li>\u5b9a\u65f6\u3001\u573a\u666f\u3001\u80fd\u8017\u7edf\u8ba1\u4e00\u5c4f\u638c\u63a7<\/li>\n              <li>\u53ef\u8bbe\u513f\u7ae5\u623f\u591c\u95f4\u9759\u97f3\u4e0e\u5b9a\u65f6\u5173\u673a<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <div class=\"flip\" tabindex=\"0\">\n        <div class=\"flip-inner\">\n          <div class=\"face front\">\n            <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-pj-kzq-gqcp-xkq.jpg\" alt=\"\u65e5\u7acb\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668\">\n            <div class=\"cap\">\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668\uff08\u65b9\u6848\u4e8c \u00b7 \u5c0a\u777f\u5168\u6548\uff09<\/div>\n          <\/div>\n          <div class=\"face back\">\n            <h4>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668 \u00b7 \u5356\u70b9<\/h4>\n            <ul>\n              <li>\u578b\u53f7 PC-P1HPQA\uff0c\u6bcf\u53f0\u5185\u673a\u914d 1 \u4e2a<\/li>\n              <li>\u9ad8\u6e05\u5f69\u5c4f\uff0c\u6e29\u6e7f\u5ea6 \/ \u6a21\u5f0f\u4e00\u76ee\u4e86\u7136<\/li>\n              <li>\u5347\u7ea7 Wi-Fi\uff0bBLE\uff0c\u652f\u6301\u8fdc\u7a0b\u4e0e\u667a\u80fd\u8054\u52a8<\/li>\n              <li>\u6e7f\u5ea6\u6570\u503c\u76f4\u63a5\u663e\u793a\uff0c\u56de\u5357\u5929\u770b\u5f97\u89c1<\/li>\n            <\/ul>\n          <\/div>\n        <\/div>\n      <\/div>\n\n    <\/div>\n    <p class=\"flip-hint\">\u63d0\u793a\uff1a\u9f20\u6807\u60ac\u505c\u6216\u70b9\u51fb\u5361\u7247\u53ef\u67e5\u770b\u80cc\u9762\u5356\u70b9\u3002<\/p>\n\n    <h3 class=\"cmp-sub\">\u4e13\u9879\u8bf4\u660e \u00b7 PE \u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff08\u65b9\u6848\u4e00\u7684\u9009\u914d\u9879\uff09<\/h3>\n    <p class=\"lead\">\u8fd9\u53ea\u6a21\u5757\u88c5\u5728\u5185\u673a\u56de\u98ce\u53e3\uff0c\u628a\u7a7a\u6c14<b>\u5148\u62e6\u4e00\u904d\u518d\u9001\u8fdb\u623f\u95f4<\/b>\u2014\u2014\u548c\u201c\u623f\u95f4\u91cc\u518d\u653e\u4e00\u53f0\u51c0\u5316\u5668\u201d\u662f\u4e24\u79cd\u601d\u8def\uff1a\u524d\u8005\u5904\u7406\u7684\u662f\u6574\u4e2a\u623f\u95f4\u7684\u5faa\u73af\u98ce\uff0c\u4e0d\u5360\u5730\u9762\u3001\u4e0d\u989d\u5916\u5360\u63d2\u5ea7\u3001\u4e0d\u9700\u8981\u5355\u72ec\u5f00\u5173\u3002\u60a8\u6ca1\u63d0\u8fc7\u654f\u95ee\u9898\uff0c\u6240\u4ee5\u672c\u6848\u628a\u5b83\u5217\u4e3a<b>\u9009\u914d<\/b>\uff0c\u4e0d\u9ed8\u8ba4\u914d\u8fdb\u62a5\u4ef7\u3002<\/p>\n    <table class=\"cmp-table\">\n      <thead><tr><th style=\"width:40%\">\u68c0\u6d4b\u9879\u76ee<\/th><th style=\"width:22%\">\u53bb\u9664\u7387<\/th><th>\u5bf9\u5c45\u5bb6\u7a7a\u6c14\u7684\u610f\u4e49<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>PM2.5<\/th><td class=\"hitachi\">99%<\/td><td>\u7ec6\u9897\u7c92\u7269\u662f\u6700\u666e\u904d\u7684\u547c\u5438\u9053\u523a\u6fc0\u6e90<\/td><\/tr>\n        <tr><th>\u5c18\u87a8<\/th><td class=\"hitachi\">98.63%<\/td><td>\u5e8a\u54c1\u4e0e\u7ec7\u7269\u662f\u4e3b\u8981\u805a\u96c6\u5904<\/td><\/tr>\n        <tr><th>\u82b1\u7c89\uff08\u9ad8\u7f8a\u8305 \/ \u8c5a\u8349\uff09<\/th><td class=\"hitachi\">99.28% \/ 95.97%<\/td><td>\u6625\u5b63\u5f00\u7a97\u671f\u7684\u4e3b\u8981\u56f0\u6270<\/td><\/tr>\n        <tr><th>\u732b\u72d7\u76ae\u5c51<\/th><td class=\"hitachi\">97.22%<\/td><td>\u517b\u5ba0\u5bb6\u5ead\u5e38\u89c1<\/td><\/tr>\n        <tr><th>\u7532\u578b\u6d41\u611f H3N2\uff081 \u5c0f\u65f6\uff09<\/th><td class=\"hitachi\">99.91%<\/td><td>\u5b69\u5b50\u4ece\u5b66\u6821\u5e26\u56de\u75c5\u6bd2\u7684\u6982\u7387\u4e0b\u964d<\/td><\/tr>\n        <tr><th>\u5927\u80a0\u6746\u83cc \/ \u91d1\u9ec4\u8272\u8461\u8404\u7403\u83cc<\/th><td class=\"hitachi\">99% \/ 97.4%<\/td><td>\u51cf\u5c11\u673a\u5185\u6f6e\u6e7f\u6ecb\u751f\u7684\u7ec6\u83cc\u968f\u98ce\u5439\u51fa<\/td><\/tr>\n        <tr><th>\u7532\u919b<\/th><td class=\"hitachi\">88.6%<\/td><td>\u65b0\u5bb6\u5177\u3001\u677f\u6750\u7684\u6301\u7eed\u91ca\u653e\uff08\u65b0\u623f\u5c24\u5176\u76f8\u5173\uff09<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <p class=\"cmp-note\">\u68c0\u6d4b\u6570\u636e\u6765\u6e90\uff1aSGS \u4e0e\u65e5\u672c\u5317\u91cc\u7814\u7a76\u6240\u3002\u4ee5\u4e0a\u4e3a\u5b9e\u9a8c\u5ba4\u68c0\u6d4b\u503c\uff0c\u5b9e\u9645\u5ba4\u5185\u53bb\u9664\u7387\u53d7\u623f\u95f4\u4f53\u79ef\u3001\u6362\u6c14\u6b21\u6570\u3001\u6ee4\u7f51\u79ef\u5c18\u5f71\u54cd\uff0c\u4f1a\u4f4e\u4e8e\u5b9e\u9a8c\u5ba4\u6570\u636e\u3002<b>\u672c\u518c\u4e0d\u5c06\u5176\u8868\u8ff0\u4e3a\u533b\u7597\u6548\u679c\u3002<\/b>\u6a21\u5757\u5c5e\u8017\u6750\uff0c\u5efa\u8bae 12\u201318 \u4e2a\u6708\u66f4\u6362\u4e00\u6b21\u3002<\/p>\n  <\/section>\n\n  <section id=\"s-craft\">\n    <h2 class=\"sec\">\u7cbe\u5de5\u516d\u6b65\u6cd5 \u00b7 \u65bd\u5de5\u8fc7\u7a0b\u56fe\u6587<\/h2>\n    <p class=\"lead\">\u4ee5\u4e0b\u5b9e\u62cd\u56fe\u53d6\u81ea\u9f99\u8109\u6807\u51c6\u5316\u65bd\u5de5\u8282\u70b9\uff1a\u8bbe\u5907\u8fdb\u573a \u2192 \u94dc\u7ba1\u58c1\u539a\u6838\u9a8c \u2192 \u6c2e\u6c14\u4fdd\u62a4\u710a \u2192 \u51cf\u9707\u5b89\u88c5 \u2192 \u8c03\u8bd5 \u2192 \u9690\u853d\u9a8c\u6536 \u2192 \u4ea4\u4ed8\u6559\u5b66\u3002\u6bcf\u4e00\u6b65\u7559\u5f71\uff0c\u9690\u853d\u5de5\u7a0b\u53ef\u8ffd\u6eaf\u3002<\/p>\n    <div class=\"gallery\">\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-sbcljc.jpg\" alt=\"\u8bbe\u5907\u6750\u6599\u8fdb\u573a\"><figcaption>\u2460 \u8bbe\u5907\u6750\u6599\u8fdb\u573a<\/figcaption><\/figure>\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbhd.jpg\" alt=\"\u94dc\u7ba1\u58c1\u539a\u6838\u9a8c\"><figcaption>\u2461 \u94dc\u7ba1\u58c1\u539a\u6838\u9a8c<\/figcaption><\/figure>\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-tgbh.jpg\" alt=\"\u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a\"><figcaption>\u2462 \u94dc\u7ba1\u6c2e\u6c14\u4fdd\u62a4\u710a<\/figcaption><\/figure>\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-snmjzd.jpg\" alt=\"\u53cc\u87ba\u6bcd\u51cf\u9707\u57ab\"><figcaption>\u2463 \u53cc\u87ba\u6bcd\u51cf\u9707\u57ab<\/figcaption><\/figure>\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbts.jpg\" alt=\"\u73b0\u573a\u8bbe\u5907\u8c03\u8bd5\"><figcaption>\u2464 \u73b0\u573a\u8bbe\u5907\u8c03\u8bd5<\/figcaption><\/figure>\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-yqysd.jpg\" alt=\"\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\"><figcaption>\u2465 \u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/figcaption><\/figure>\n      <figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-jgaz-xcsbjx.jpg\" alt=\"\u73b0\u573a\u8bbe\u5907\u6559\u5b66\"><figcaption>\u2466 \u73b0\u573a\u8bbe\u5907\u6559\u5b66<\/figcaption><\/figure>\n    <\/div>\n  <\/section>\n\n  <section id=\"s-cmp\">\n    <h2 class=\"sec\">\u4e09\u5927\u54c1\u724c\u6a2a\u8bc4 <small>\u65e5\u7acb vs \u683c\u529b vs \u7f8e\u7684<\/small><\/h2>\n\n    <div class=\"cmp-sub\">\u4e00\u3001\u54c1\u724c\u4e0e\u6280\u672f\u5e95\u8574<\/div>\n    <table class=\"cmp-table\">\n      <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u65e5\u7acb<\/th><th>\u683c\u529b<\/th><th>\u7f8e\u7684<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u5386\u53f2<\/th><td class=\"hitachi\">\u59cb\u4e8e 1910 \u5e74 \u00b7 114 \u5e74\uff0b<\/td><td>\u59cb\u4e8e 1991 \u5e74 \u00b7 33 \u5e74<\/td><td>\u59cb\u4e8e 1968 \u5e74<\/td><\/tr>\n        <tr><th>\u4e16\u754c 500 \u5f3a<\/th><td class=\"hitachi\">\u662f \u00b7 2023 \u5168\u7403 153 \u4f4d \u00b7 \u7a7a\u8c03\u7c7b\u7b2c\u4e00<\/td><td>\u5426\uff08\u672a\u5165\u699c\uff09<\/td><td>\u662f\uff08\u5165\u699c\uff09<\/td><\/tr>\n        <tr><th>\u538b\u7f29\u673a<\/th><td class=\"hitachi\"><b>\u81ea\u4ea7\u53cc\u8f6c\u5b50<\/b>\uff08125 \u53ca\u4ee5\u4e0b\u4e2d\u5c0f\u5bb9\u91cf\uff09\uff0f\u6da1\u65cb\uff08\u5927\u5bb9\u91cf\uff0c1983 \u5e74\u6da1\u65cb\u53d1\u660e\u8005\uff09<\/td><td>\u51cc\u8fbe\uff08\u90e8\u5206\u5916\u91c7\u4e09\u83f1\uff09<\/td><td>\u7f8e\u829d\u55b7\u6c14\u589e\u7113\uff08\u5408\u8d44\uff09<\/td><\/tr>\n        <tr><th>\u53d8\u9891\u6280\u672f<\/th><td class=\"hitachi\">\u81ea\u6709 0.01Hz \u65e0\u7ea7\u53d8\u9891<\/td><td>\u5916\u91c7 1Hz<\/td><td>\u4f4e\u9891 6Hz<\/td><\/tr>\n        <tr><th>\u6838\u5fc3\u9600\u4ef6<\/th><td class=\"hitachi\">\u4e0d\u4e8c\u5de5\u673a\u7535\u5b50\u81a8\u80c0\u9600\uff082000 \u7ea7\uff09<\/td><td>480 \u7ea7<\/td><td>\u2014<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"cmp-sub\">\u4e8c\u3001\u6838\u5fc3\u6027\u80fd\u5bf9\u6bd4\uff08\u540c\u7ea7\uff1a\u65e5\u7acb\u8212\u4eab \/ \u683c\u529b STAR5\u00b7\u2162 \/ \u7f8e\u7684\u9886\u822a\u8005 4\uff09<\/div>\n    <table class=\"cmp-table\">\n      <thead><tr><th>\u7ef4\u5ea6<\/th><th>\u65e5\u7acb\u8212\u4eab<\/th><th>\u683c\u529b STAR5\/\u2162<\/th><th>\u7f8e\u7684\u9886\u822a\u8005 4<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u9ad8\u6e29\u5236\u51b7<\/th><td class=\"hitachi\">59\u2103 \u4e0d\u8870\u51cf\uff08\u76f4\u51b7\u4e00\u4f53\u6563\u70ed\uff0b\u5927\u98ce\u6247\uff09<\/td><td>-35~66\u2103 \u5bbd\u6e29<\/td><td>-35~65\u2103 \u00b7 48\u2103 \u4e0d\u8870\u51cf<\/td><\/tr>\n        <tr><th>\u4f4e\u6e29\u9664\u6e7f<\/th><td class=\"hitachi\">10\u2103 \u4f4e\u6e29\u9664\u6e7f \uff0b 56 \u6863\u6e7f\u5ea6\uff08\u6210\u90fd\u56de\u5357\u5929\u53ef\u7528\uff09<\/td><td>\u65e0 10\u2103 \u9664\u6e7f\u80fd\u529b<\/td><td>\u8d85\u4f4e\u6e29\u9664\u6e7f<\/td><\/tr>\n        <tr><th>\u9632\u6ce1\u9876<\/th><td class=\"hitachi\">\u6807\u914d\u6c34\u6cf5 \uff0b \u6d6e\u5b50\u5f00\u5173\uff08\u53cc\u91cd\u4fdd\u9669\uff09<\/td><td>\u6709\u6cf5\u673a\u578b\u5e02\u573a\u5c11 \u00b7 \u65e0\u6d6e\u5b50\u5f00\u5173<\/td><td>\u6807\u914d\u6c34\u6cf5<\/td><\/tr>\n        <tr><th>\u9759\u97f3<\/th><td class=\"hitachi\">\u5185\u673a 17dB<\/td><td>20\u201322dB<\/td><td>17dB<\/td><\/tr>\n        <tr><th>\u81ea\u6e05\u6d01<\/th><td class=\"hitachi\">\u4e8c\u6b21\u7ed3\u51b0 \uff0b \u6c34\u6cf5\u6392\u6c61\u6c34\uff08\u5f7b\u5e95\uff09<\/td><td>\u7ed3\u971c\u81ea\u6e05\u6d01\uff08\u65e0\u6cf5\u6613\u810f\u5835\uff09<\/td><td>\u4e8c\u6b21\u7ed3\u51b0 \uff0b 60\u2103 \u9ad8\u6e29\u6740\u83cc<\/td><\/tr>\n        <tr><th>\u80fd\u6548 APF<\/th><td class=\"hitachi\">\u7cfb\u5217\u6700\u9ad8 6.1\uff08\u4e00\u7ea7\uff09<\/td><td>\u6700\u9ad8 6.6<\/td><td>\u4e00\u7ea7<\/td><\/tr>\n        <tr><th>\u8d28\u4fdd<\/th><td class=\"hitachi\">\u6574\u673a 5 \u5e74\uff1b\u54c1\u724c\u6708\u6d3b\u52a8\u53ef\u4eab 10 \u5e74\uff08\u4ee5\u5f53\u671f\u653f\u7b56\u4e3a\u51c6\uff09<\/td><td>\u6807\u51c6\u8d28\u4fdd<\/td><td>\u6807\u51c6\u8d28\u4fdd<\/td><\/tr>\n        <tr><th>\u540e\u671f\u8d39\u7528<\/th><td class=\"hitachi\">\u65e0\u7535\u8f85\u70ed \u00b7 \u5e74\u7701\u7ea6 \u00a5961<\/td><td>\u5e26\u7535\u8f85\u70ed \u00b7 \u5e74\u591a\u8017\u7535\u7ea6 1780 \u5ea6<\/td><td>\u2014<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"cmp-sub\">\u4e09\u3001\u5173\u952e\u5dee\u5f02\u70b9\u89e3\u8bfb\uff08\u8bda\u5b9e\u9762\u5bf9\u53c2\u6570\uff09<\/div>\n    <table class=\"cmp-table\">\n      <thead><tr><th>\u7ade\u54c1\u53c2\u6570<\/th><th>\u771f\u76f8\u89e3\u8bfb<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u683c\u529b STAR5 \u5bbd\u6e29\u57df -35~66\u2103 \/ APF 6.6<\/th><td>\u53c2\u6570\u786e\u5b9e\u9886\u5148\uff0c\u4f46\u4f4e\u9891\u8fc7\u4f4e\u53cd\u800c\u6613\u8017\u80fd\uff1b\u65e5\u7acb 25\u201335Hz \u9ec4\u91d1\u5e73\u8861\u70b9\u66f4\u7a33\u66f4\u8212\u9002<\/td><\/tr>\n        <tr><th>\u683c\u529b\u201c\u5168\u94dc\u7535\u673a\u201d<\/th><td>\u65e5\u7acb\u5185\u673a\u4e3a\u94dd\u7ebf\u7535\u673a\uff08\u884c\u4e1a\u8d8b\u52bf\uff09\uff0c\u4ee5\u539f\u88c5\u538b\u7f29\u673a \uff0b \u957f\u671f\u8d28\u4fdd\u5bf9\u51b2<\/td><\/tr>\n        <tr><th>\u7f8e\u7684\u201c\u4e00\u665a\u4e00\u5ea6\u7535\u201d\uff086Hz\uff09<\/th><td>\u6781\u4f4e\u9891 \u2260 \u7528\u6237\u5b9e\u9645\u4ef7\u503c\uff1b\u65e5\u7acb 2000 \u7ea7\u7535\u5b50\u81a8\u80c0\u9600 \uff0b \u7cfb\u7edf\u4f18\u5316\u66f4\u7701<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n    <p class=\"cmp-note\">\u65e5\u7acb\u6838\u5fc3\u4f18\u52bf\uff08\u6210\u90fd\u573a\u666f\u9002\u7528\uff09\uff1a\u2460 10\u2103 \u4f4e\u6e29\u9664\u6e7f \uff0b 56 \u6863\u6e7f\u5ea6\uff0c\u4e13\u6cbb\u6210\u90fd\u56de\u5357\u5929\uff1b\u2461 \u81ea\u4ea7\u53cc\u8f6c\u5b50\u538b\u7f29\u673a \uff0b 2000 \u7ea7\u7535\u5b50\u81a8\u80c0\u9600\uff0c\u90e8\u5206\u8d1f\u8377\u4e0b\u7cfb\u7edf\u66f4\u7a33\u66f4\u7701\uff1b\u2462 \u6807\u914d\u6c34\u6cf5 \uff0b \u6d6e\u5b50\u5f00\u5173\u53cc\u91cd\u9632\u6ce1\u9876\uff0c\u675c\u7edd\u540a\u9876\u6ce1\u9876\u9690\u60a3\u3002<\/p>\n\n    <div class=\"cmp-sub\">\u56db\u3001\u4e09\u5bb6\u6a2a\u5411\u7ed3\u8bba\uff08\u4e00\u53e5\u8bdd\u600e\u4e48\u9009\uff09<\/div>\n    <p class=\"cmp-note cmp-note-lg\">\u8ffd\u6c42\u6700\u4f4e\u521d\u6295\u3001\u4e14\u4e0e\u683c\u529b\/\u7f8e\u7684\u540c\u6863\u4ef7\uff1a\u9009 <b>\u65e5\u7acb\u8212\u4eab 125<\/b>\uff0c\u7528\u65e5\u7acb\u538b\u7f29\u673a\u5e95\u8574\u6362\u540c\u4ef7\u4f4d\u66f4\u7a33\u7684\u7cfb\u7edf\u3002\u91cd\u89c6\u6e29\u6e7f\u53cc\u63a7\u3001\u5168\u5c4b\u51c0\u5316\u3001\u4ee5\u53ca\u60f3\u8981\u201c\u4e00\u53f0\u4e3b\u673a\u5e26\u7a7a\u8c03\uff0b\u5730\u6696\u201d\uff1a\u9009 <b>\u5c0a\u777f\u5168\u6548 125<\/b>\uff0c\u5bf9\u6807\u5927\u91d1\u4ef7\u683c\u66f4\u53cb\u597d\u3002\u4e24\u79cd\u65b9\u6848\u5747\u7531\u9f99\u8109\u6696\u901a\u672c\u5730\u56e2\u961f\u5b89\u88c5 \uff0b \u7ba1\u5bb6\u5f0f\u552e\u540e\uff0c\u5230\u5e97\uff08\u5357\u5bcc\u68ee \/ \u5317\u5bcc\u68ee\uff09\u53ef\u5b9e\u673a\u4f53\u9a8c\u3002<\/p>\n  <\/section>\n\n  <section id=\"s-quote\">\n    <h2 class=\"sec\">\u4e2d\u592e\u7a7a\u8c03\u62a5\u4ef7\u660e\u7ec6 <small>\u8bbe\u5907\u4ef7 \uff0b \u5b89\u88c5\u8d39\u9010\u9879\u5bf9\u5e94 \u00b7 \u7b7e\u7ea6\u524d\u6309\u95e8\u5e97\u73b0\u884c\u653f\u7b56\u590d\u6838<\/small><\/h2>\n\n    <div class=\"quote\">\n      <div class=\"qhead\">4.1 \u65b9\u6848\u4e00 \u00b7 \u8212\u4eab 125 \u5355\u98ce\u6247 \u00b7 \u4e00\u62d6\u56db<\/div>\n      <table>\n        <thead>\n          <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u8bbe\u5907\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>1<\/td><td>\u8212\u4eab 125 \u5355\u98ce\u6247\u5916\u673a<\/td><td>RAS-125HRNAQ<\/td><td>9,330.40<\/td><td>\u5df2\u542b<\/td><td>9,330.40<\/td><\/tr>\n          <tr><td>2<\/td><td>\u5ba2\u9910\u5385\u53a8\u623f\u5185\u673a 71 \u578b<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>2,810.40<\/td><td>1,600.00<\/td><td>4,410.40<\/td><\/tr>\n          <tr><td>3<\/td><td>\u4e3b\u5367\u5185\u673a 36 \u578b<\/td><td>RPIZ-36FSNAQD\/P<\/td><td>2,500.00<\/td><td>1,600.00<\/td><td>4,100.00<\/td><\/tr>\n          <tr><td>4<\/td><td>\u513f\u7ae5\u623f\u5185\u673a 22 \u578b<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2,410.40<\/td><td>1,600.00<\/td><td>4,010.40<\/td><\/tr>\n          <tr><td>5<\/td><td>\u6b21\u5367\u5185\u673a 22 \u578b<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2,410.40<\/td><td>1,600.00<\/td><td>4,010.40<\/td><\/tr>\n          <tr class=\"ctrl\"><td>6<\/td><td>WiFi \u7ebf\u63a7\u5668 \u00d74\uff08\u6bcf\u5185\u673a 1 \u4e2a\uff09<\/td><td>PC-P1HVQA<\/td><td>1,000.00<\/td><td>\u5df2\u542b<\/td><td>1,000.00<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"total\">\u65b9\u6848\u4e00 \u4e2d\u592e\u7a7a\u8c03\u5408\u8ba1\uff08\u8bbe\u5907 \uff0b \u5b89\u88c5 \uff0b \u7ebf\u63a7\u5668\uff09\uff1a\uffe5 26,861.60<\/div>\n    <\/div>\n\n    <div class=\"quote\">\n      <div class=\"qhead\">4.2 \u65b9\u6848\u4e8c \u00b7 \u5c0a\u777f\u5168\u6548 125 \u00b7 \u4e09\u7ba1\u5236\u4e00\u62d6\u56db<\/div>\n      <table>\n        <thead>\n          <tr><th>\u5e8f\u53f7<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7<\/th><th>\u8bbe\u5907\u4ef7<\/th><th>\u5b89\u88c5\u8d39<\/th><th>\u5c0f\u8ba1<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>1<\/td><td>\u5c0a\u777f\u5168\u6548 125 \u5916\u673a<\/td><td>RAS-125FSXPN5Q<\/td><td>15,300.00<\/td><td>\u5df2\u542b<\/td><td>15,300.00<\/td><\/tr>\n          <tr><td>2<\/td><td>\u5ba2\u9910\u5385\u53a8\u623f\u4e09\u7ba1\u5236\u5185\u673a 71 \u578b<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>4,660.00<\/td><td>1,800.00<\/td><td>6,460.00<\/td><\/tr>\n          <tr><td>3<\/td><td>\u4e3b\u5367\u4e09\u7ba1\u5236\u5185\u673a 36 \u578b<\/td><td>RPIZ-36FSVN2QB\/PC<\/td><td>4,190.40<\/td><td>1,800.00<\/td><td>5,990.40<\/td><\/tr>\n          <tr><td>4<\/td><td>\u513f\u7ae5\u623f\u4e09\u7ba1\u5236\u5185\u673a 22 \u578b<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>4,040.00<\/td><td>1,800.00<\/td><td>5,840.00<\/td><\/tr>\n          <tr><td>5<\/td><td>\u6b21\u5367\u4e09\u7ba1\u5236\u5185\u673a 22 \u578b<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>4,040.00<\/td><td>1,800.00<\/td><td>5,840.00<\/td><\/tr>\n          <tr class=\"ctrl\"><td>6<\/td><td>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668 \u00d74\uff08\u6bcf\u5185\u673a 1 \u4e2a\uff09<\/td><td>PC-P1HPQA<\/td><td>2,100.00<\/td><td>\u5df2\u542b<\/td><td>2,100.00<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n      <div class=\"total\">\u65b9\u6848\u4e8c \u4e2d\u592e\u7a7a\u8c03\u5408\u8ba1\uff08\u8bbe\u5907 \uff0b \u5b89\u88c5 \uff0b \u7ebf\u63a7\u5668\uff09\uff1a\uffe5 41,530.40<\/div>\n    <\/div>\n\n    <div class=\"vs\">\n      <div class=\"box a\"><h4>\u65b9\u6848\u4e00 \u8212\u4eab 125<\/h4><div class=\"big\">\uffe526,861.60<\/div><p style=\"font-size:12.5px;color:#666;margin:6px 0 0\">\u521d\u6295\u6700\u4f4e \u00b7 \u5236\u51b7\u591f\u7528\uff0c\u5dee\u4ef7\u7559\u7ed9\u5730\u6696<\/p><\/div>\n      <div class=\"box b\"><h4>\u65b9\u6848\u4e8c \u5c0a\u777f\u5168\u6548 125<\/h4><div class=\"big\">\uffe541,530.40<\/div><p style=\"font-size:12.5px;color:#666;margin:6px 0 0\">\u6e29\u6e7f\u53cc\u63a7 \uff0b \u5168\u98ce\u8def\u51c0\u5316 \uff0b \u53ef\u63a5\u6c34\u6a21\u5757\u505a\u5730\u6696<\/p><\/div>\n    <\/div>\n\n    <div class=\"stack\">\n      <p class=\"stack-t\">14,668.80 \u5143\u5dee\u4ef7\u91cc\uff0c\u4e3b\u673a\u53ea\u5360 6 \u5343\uff0c\u5185\u673a\u4e0e\u5b89\u88c5\u5408\u8ba1\u5360\u4e86 8 \u5343\u2014\u2014\u5dee\u4ef7\u4e0d\u662f\u4e00\u53f0\u673a\u5668\u7684\u4e8b\u3002<\/p>\n      <div class=\"stack-row\">\n        <div class=\"stack-name\">\u65b9\u6848\u4e00<\/div>\n        <div class=\"stack-bar\">\n          <span style=\"width:34.73%;background:#b8860b\" title=\"\u5916\u673a 9,330.40\">\u5916\u673a 9,330<\/span>\n          <span style=\"width:37.72%;background:#c8102e\" title=\"\u5185\u673a\u8bbe\u5907 10,131.20\">\u5185\u673a 10,131<\/span>\n          <span style=\"width:23.83%;background:#8a6a12\" title=\"\u5b89\u88c5\u8d39 6,400\">\u5b89\u88c5 6,400<\/span>\n          <span style=\"width:3.72%;background:#9e0c24\" title=\"\u7ebf\u63a7\u5668 1,000\"><\/span>\n        <\/div>\n        <div class=\"stack-sum\">\uffe526,861.60<\/div>\n      <\/div>\n      <div class=\"stack-row\">\n        <div class=\"stack-name\">\u65b9\u6848\u4e8c<\/div>\n        <div class=\"stack-bar\">\n          <span style=\"width:36.84%;background:#b8860b\" title=\"\u5916\u673a 15,300\">\u5916\u673a 15,300<\/span>\n          <span style=\"width:40.77%;background:#c8102e\" title=\"\u5185\u673a\u8bbe\u5907 16,930.40\">\u5185\u673a 16,930<\/span>\n          <span style=\"width:17.33%;background:#8a6a12\" title=\"\u5b89\u88c5\u8d39 7,200\">\u5b89\u88c5 7,200<\/span>\n          <span style=\"width:5.06%;background:#9e0c24\" title=\"\u7ebf\u63a7\u5668 2,100\"><\/span>\n        <\/div>\n        <div class=\"stack-sum\">\uffe541,530.40<\/div>\n      <\/div>\n      <div class=\"stack-lg\">\n        <span><i style=\"background:#b8860b\"><\/i>\u5916\u673a<\/span>\n        <span><i style=\"background:#c8102e\"><\/i>\u5185\u673a\u8bbe\u5907<\/span>\n        <span><i style=\"background:#8a6a12\"><\/i>\u5b89\u88c5\u8d39<\/span>\n        <span><i style=\"background:#9e0c24\"><\/i>\u7ebf\u63a7\u5668\uff08\u6bb5\u592a\u7a84\uff0c\u6570\u503c\u89c1\u62a5\u4ef7\u8868\uff09<\/span>\n      <\/div>\n      <p class=\"stack-read\">\u600e\u4e48\u8bfb\uff1a\u540c\u8272\u6bb5\u8d8a\u957f\uff0c\u8fd9\u4e00\u9879\u82b1\u5f97\u8d8a\u591a\uff1b\u4e24\u884c\u53f3\u7aef\u603b\u6570\u4e4b\u5dee\uff0c\u5c31\u662f 14,668.80 \u5143\u7684\u4ef7\u5dee\u3002<\/p>\n    <\/div>\n\n    <div class=\"note\">\n      <b>\u62a5\u4ef7\u8bf4\u660e\uff1a<\/b><br>\n      \u2460 \u4e24\u65b9\u6848\u4ef7\u5dee <b>\uffe514,668.80<\/b>\u3002\u65b9\u6848\u4e8c\u591a\u51fa\u7684\u662f\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0818\u2103 \u4e0d\u964d\u6e29\u9664\u6e7f\uff09\u3001\u51fa\u5382\u81ea\u5e26\u7684\u5168\u98ce\u8def\u51c0\u5316\u8231\u3001\u66f4\u5f3a\u7684\u4f4e\u6e29\u5236\u70ed\uff08\u5907\u7528\uff09\uff0c\u4ee5\u53ca\u63a5\u6c34\u6a21\u5757\u505a\u5730\u6696\u7684\u63a5\u53e3\u3002<b>\u6309\u201c\u5236\u51b7\u4e3a\u4e3b \uff0b \u8981\u505a\u5730\u6696\u201d\u8fd9\u4e2a\u8bc9\u6c42\u770b\uff0c\u65b9\u6848\u4e00\u7684\u5236\u51b7\u90e8\u5206\u5df2\u7ecf\u591f\u7528\uff0c\u5dee\u4ef7\u4e70\u7684\u662f\u53e6\u5916\u4e09\u4ef6\u4e8b\u3002<\/b><br>\n      \u2461 \u65b9\u6848\u4e00\u53ef\u9009\u914d <b>PE \u7eaf\u51c0\u751f\u6001\u6a21\u5757 \u00d74\uff08\uffe51,600\uff09<\/b>\uff0c\u914d\u9f50\u540e\u5408\u8ba1 <b>\uffe528,461.60<\/b>\u3002\u60a8\u6ca1\u6709\u660e\u786e\u7684\u8fc7\u654f\u8bc9\u6c42\uff0c\u6240\u4ee5\u5217\u4e3a\u9009\u914d\u800c\u975e\u9ed8\u8ba4\uff1b\u5982\u679c\u5bb6\u91cc\u6709\u4eba\u5bb9\u6613\u6253\u55b7\u568f\u3001\u6216\u5bf9\u88c5\u4fee\u540e\u7684\u7532\u919b\u5728\u610f\uff0c\u5efa\u8bae\u52a0\u4e0a\u3002<br>\n      \u2462 <b>\u6c34\u6a21\u5757\u4e0e\u5730\u6696\u7cfb\u7edf\u4e0d\u5728\u672c\u518c\u62a5\u4ef7\u8303\u56f4\u5185<\/b>\uff0c\u4f1a\u53e6\u9644\u5730\u6696\u4e13\u9879\u65b9\u6848\u4e0e\u62a5\u4ef7\uff08\u542b\u76d8\u7ba1\u3001\u4fdd\u6e29\u3001\u56de\u586b\u3001\u5206\u96c6\u6c34\u5668\u3001\u63a7\u5236\u4e0e\u70ed\u6e90\uff09\u3002<br>\n      \u2463 \u5b89\u88c5\u8d39\u53e3\u5f84\u4e3a\u660e\u9879\uff1a\u8212\u4eab\u5185\u673a 1,600 \u5143\/\u53f0\u3001\u5c0a\u777f\u4e09\u7ba1\u5236\u5185\u673a 1,800 \u5143\/\u53f0\uff0c\u5916\u673a\u5b89\u88c5\u5df2\u542b\u5728\u8bbe\u5907\u4ef7\u5185\u3002\u94dc\u7ba1\u8d85\u51fa\u6807\u51c6\u957f\u5ea6\u3001\u6253\u5b54\u3001\u540a\u9876\u4fee\u590d\u7b49\u6309\u73b0\u573a\u5b9e\u9645\u53e6\u8ba1\u3002\n    <\/div>\n\n    <div class=\"remark\">\n      <b>\u65b9\u6848\u4e66\u6027\u8d28\u8bf4\u660e\uff08\u8bf7\u52a1\u5fc5\u9605\u8bfb\uff09<\/b>\n      <p style=\"margin:0;\">\u672c\u65b9\u6848\u4e66\u5b9a\u4f4d\u4e3a<b>\u6280\u672f\u6807<\/b>\u2014\u2014\u7528\u4e8e\u6e05\u6670\u5448\u73b0\u7cfb\u7edf\u914d\u7f6e\u3001\u6280\u672f\u53c2\u6570\uff0c\u4ee5\u53ca\u914d\u7f6e\u4e0e\u4ef7\u683c\u7684\u4e00\u4e00\u5bf9\u5e94\u5173\u7cfb\uff0c\u4fbf\u4e8e\u6280\u672f\u5c42\u9762\u6bd4\u8f83\uff0c<b>\u800c\u975e\u4e00\u6b21\u6027\u5c01\u6807\u62a5\u4ef7\uff08\u4ef7\u683c\u6807\uff09<\/b>\u3002<\/p>\n      <ol>\n        <li>\u6696\u901a\u884c\u4e1a\u4ef7\u683c\u9ad8\u5ea6\u900f\u660e\uff0c\u4efb\u4f55\u4e00\u4efd\u62a5\u4ef7\u4e4b\u5916\uff0c\u5e02\u573a\u4e0a\u90fd\u53ef\u80fd\u5b58\u5728\u66f4\u4f4e\u51fa\u4ef7\uff1a\u90e8\u5206\u5546\u5bb6\u4f1a\u5148\u4ee5\u8d85\u4f4e\u4ef7\u4e89\u53d6\u8ba2\u5355\uff0c\u518d\u901a\u8fc7\u540e\u671f\u589e\u9879\u3001\u964d\u914d\u7b49\u65b9\u5f0f\u5e73\u8861\u6210\u672c\u3002<\/li>\n        <li>\u672c\u518c\u6240\u5217\u4ef7\u683c\u4e3a\u9f99\u8109\u57fa\u4e8e\u6807\u51c6\u914d\u7f6e\u4e0e\u5382\u5bb6\u653f\u7b56\u7684<b>\u53c2\u8003\u62a5\u4ef7<\/b>\uff0c\u4e0d\u4ee3\u8868\u6700\u7ec8\u6210\u4ea4\u4ef7\uff0c\u4e5f\u4e0d\u6784\u6210\u4e00\u6b21\u6027\u5c01\u6807\u627f\u8bfa\u3002<\/li>\n        <li>\u9664\u975e\u53cc\u65b9\u91c7\u7528\u4e00\u6b21\u6027\u5c01\u6807\u62a5\u4ef7\u673a\u5236\uff0c\u5426\u5219\u6211\u4eec\u4e0d\u4f1a\u5728\u65b9\u6848\u4e66\u4e2d\u7ed9\u51fa\u6700\u4f4e\u4ef7\u2014\u2014\u6700\u4f4e\u4ef7\u8bf7\u5728\u60a8\u5bf9\u6bd4\u6e05\u695a\u3001\u57fa\u672c\u786e\u5b9a\u914d\u7f6e\u3001\u51c6\u5907\u5b9a\u6848\u65f6\uff0c<b>\u7ebf\u4e0b\u4e0e\u4e13\u5c5e\u987e\u95ee\u6c9f\u901a<\/b>\uff1b\u5728\u60a8\u786e\u5b9a\u8981\u5b9a\u7684\u8282\u70b9\uff0c\u6211\u4eec\u53ef\u7ed9\u51fa\u6700\u8bda\u610f\u7684\u5c01\u6807\u4ef7\u683c\u3002<\/li>\n        <li>\u8bf7\u52a1\u5fc5<b>\u5bf9\u7167\u914d\u7f6e\u770b\u4ef7\u683c<\/b>\uff1a\u4f4e\u4ef7\u82e5\u4f34\u968f\u914d\u7f6e\u7f29\u6c34\uff08\u4f8b\u5982\u628a\u4e09\u7ba1\u5236\u964d\u4e3a\u4e8c\u7ba1\u5236\u3001\u628a\u5185\u673a\u5b89\u88c5\u8d39\u538b\u5230\u4f4e\u4e8e\u5de5\u827a\u6210\u672c\u3001\u628a PE \u6a21\u5757\u6362\u6210\u7b2c\u4e09\u65b9\u6ee4\u7f51\uff09\uff0c\u9700\u81ea\u884c\u7504\u522b\u3002<\/li>\n      <\/ol>\n    <\/div>\n  <\/section>\n\n  <section id=\"s-adv\">\n    <h2 class=\"sec\">\u9009\u8d2d\u5efa\u8bae <small>\u5148\u522b\u7ea0\u7ed3\u4ef7\u683c\uff0c\u5148\u5b9a\u201c\u5730\u6696\u600e\u4e48\u63a5\u201d<\/small><\/h2>\n    <p class=\"lead\">\u8fd9\u4e24\u5957\u65b9\u6848\u5728\u201c\u5236\u51b7\u591f\u4e0d\u591f\u201d\u4e0a\u6ca1\u6709\u5dee\u522b\uff0c\u771f\u6b63\u7684\u5206\u5c94\u8def\u53e3\u662f<b>\u60a8\u5bb6\u5730\u6696\u7684\u70ed\u6e90\u600e\u4e48\u5b9a<\/b>\u3002\u628a\u8fd9\u4e2a\u60f3\u6e05\u695a\uff0c\u7b54\u6848\u57fa\u672c\u81ea\u5df1\u5c31\u51fa\u6765\u4e86\u3002<\/p>\n\n    <div class=\"cmp-sub\">\u4e00\u3001\u5148\u5bf9\u573a\u666f\uff1a\u60a8\u5bb6\u5c5e\u4e8e\u54ea\u4e00\u7c7b\uff1f<\/div>\n    <table class=\"cmp-table\">\n      <thead><tr><th style=\"width:34%\">\u60a8\u5bb6\u7684\u60c5\u51b5<\/th><th style=\"width:20%\">\u66f4\u5408\u9002<\/th><th>\u4e3a\u4ec0\u4e48\uff08\u4e0e\u4ef7\u683c\u65e0\u5173\uff09<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th>\u5730\u6696\u6253\u7b97\u7528\u71c3\u6c14\u58c1\u6302\u7089\uff0c\u9505\u7089\u4f4d\u548c\u70df\u9053\u80fd\u5b89\u6392<\/th><td class=\"rec\">\u65b9\u6848\u4e00 \u8212\u4eab 125<\/td><td>\u7a7a\u8c03\u4e0e\u91c7\u6696\u5404\u81ea\u72ec\u7acb\uff0c\u4e92\u4e0d\u5f71\u54cd\uff1b\u521d\u6295\u6700\u4f4e\uff0c\u94b1\u53ef\u4ee5\u7559\u7ed9\u5730\u6696\u4e0e\u5bb6\u5177\u3002<\/td><\/tr>\n        <tr><th>\u4e0d\u60f3\u88c5\u9505\u7089\u3001\u4e0d\u60f3\u5360\u67dc\u4f4d\u3001\u4e0d\u60f3\u5e74\u5e74\u6e05\u6d17\u4fdd\u517b<\/th><td class=\"rec\">\u65b9\u6848\u4e8c \u5c0a\u777f\u5168\u6548<\/td><td>\u6c34\u6a21\u5757\u662f\u5c01\u95ed\u56de\u8def\u6362\u70ed\uff0c\u4e0d\u7ed3\u57a2\u514d\u6e05\u6d17\u677f\u6362\uff0c20 \u5e74\u4e0e\u4e3b\u673a\u540c\u5468\u671f\u3002<\/td><\/tr>\n        <tr><th>\u6210\u90fd\u56de\u5357\u5929\u660e\u663e\uff0c\u6015\u6f6e\u3001\u6015\u9709\u5473\u3001\u6015\u623f\u95f4\u91cc\u9ecf<\/th><td class=\"rec\">\u65b9\u6848\u4e8c \u5c0a\u777f\u5168\u6548<\/td><td>\u4e09\u7ba1\u5236 18\u2103 \u4e0d\u964d\u6e29\u9664\u6e7f\uff0c\u6885\u96e8\u5b63\u628a\u6e7f\u5ea6\u538b\u4f4f\u800c\u623f\u95f4\u4e0d\u51b7\u3002<\/td><\/tr>\n        <tr><th>\u9884\u7b97\u4f18\u5148\uff0c\u5e0c\u671b\u628a\u5927\u5934\u7559\u7ed9\u5730\u6696\u548c\u8f6f\u88c5<\/th><td class=\"rec\">\u65b9\u6848\u4e00 \u8212\u4eab 125<\/td><td>26,861.60 \u5b8c\u6210 85\u33a1 \u56db\u533a\u5236\u51b7\uff0c\u9759\u97f3\u4e0e\u63a7\u6e29\u5df2\u7ecf\u5230\u4f4d\uff0c\u53ef\u9009\u914d PE \u8865\u51c0\u5316\u3002<\/td><\/tr>\n        <tr><th>\u5728\u610f\u7a7a\u6c14\u6d01\u51c0\uff08\u65b0\u623f\u3001\u5b69\u5b50\u3001\u8001\u4eba\uff09<\/th><td class=\"rec\">\u65b9\u6848\u4e00 \uff0b PE\uff0c\u6216\u65b9\u6848\u4e8c<\/td><td>\u65b9\u6848\u4e00\u662f\u201c\u81ea\u6e05\u6d01\uff0bPE \u6a21\u5757\u201d\u4e24\u9053\u62e6\uff1b\u65b9\u6848\u4e8c\u662f\u5168\u98ce\u8def\u51c0\u5316\u8231\u51fa\u5382\u81ea\u5e26\uff0c\u5c42\u7ea7\u66f4\u6df1\u3002<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <div class=\"cmp-sub\">\u4e8c\u3001\u4e09\u6761\u51b3\u7b56\u7ea2\u7ebf\uff08\u5e2e\u60a8\u5728\u4e24\u4e2a\u65b9\u6848\u95f4\u6536\u53e3\uff09<\/div>\n    <ul style=\"font-size:14px;line-height:1.9;margin:10px 0 0;padding-left:20px;\">\n      <li><b>\u786e\u5b9a\u8981\u88c5\u71c3\u6c14\u9505\u7089<\/b>\uff08\u6709\u4f4d\u7f6e\u3001\u80fd\u6392\u70df\u3001\u613f\u610f\u6bcf\u5e74\u4fdd\u517b\uff09 \u2192 \u65b9\u6848\u4e00\uff0c\u628a\u94b1\u82b1\u5728\u7a7a\u8c03\u672c\u8eab\u3002<\/li>\n      <li><b>\u786e\u5b9a\u4e0d\u8981\u9505\u7089<\/b>\uff08\u6ca1\u4f4d\u7f6e\u3001\u6015\u9ebb\u70e6\u3001\u6216\u5c0f\u533a\u5bf9\u70df\u9053\u6709\u9650\u5236\uff09 \u2192 \u5fc5\u987b\u65b9\u6848\u4e8c\uff0c\u56e0\u4e3a\u5929\u6c1f\u5730\u6c34\u53ea\u6709\u5c0a\u777f\u5168\u6548\u80fd\u63a5\u6c34\u6a21\u5757\u3002<\/li>\n      <li><b>\u8fd8\u60f3\u518d\u7b49\u7b49\u770b<\/b>\uff08\u5730\u6696\u70ed\u6e90\u6ca1\u60f3\u597d\uff09 \u2192 \u5148\u6309\u65b9\u6848\u4e8c\u9884\u7559\u63a5\u53e3\uff0c\u6216\u6309\u65b9\u6848\u4e00\u9884\u7559\u9505\u7089\u4f4d\uff1b<b>\u4f46\u5730\u6696\u76d8\u7ba1\u4e00\u5b9a\u8981\u8ddf\u88c5\u4fee\u540c\u671f\u505a<\/b>\uff0c\u8fd9\u4e00\u9879\u6ca1\u6709\u201c\u4ee5\u540e\u518d\u8bf4\u201d\u3002<\/li>\n    <\/ul>\n    <div class=\"note\">\n      \u4e00\u53e5\u8bdd\u6536\u53e3\uff1a<b>\u5148\u56de\u7b54\u201c\u9505\u7089\u8fd8\u662f\u6c34\u6a21\u5757\u201d\uff0c\u518d\u56de\u7b54\u201c\u8212\u4eab\u8fd8\u662f\u5c0a\u777f\u201d\u3002<\/b>\u7b2c\u4e00\u4e2a\u95ee\u9898\u51b3\u5b9a\u4e3b\u673a\uff0c\u7b2c\u4e8c\u4e2a\u95ee\u9898\u51b3\u5b9a\u9884\u7b97\u3002\u5982\u679c\u5730\u6696\u786e\u5b9a\u7528\u9505\u7089 \u2192 \u65b9\u6848\u4e00\u66f4\u5408\u7b97\uff1b\u5982\u679c\u786e\u5b9a\u4e0d\u88c5\u9505\u7089 \u2192 \u5728\u65e5\u7acb\u5bb6\u88c5\u7ebf\u91cc\uff0c\u65b9\u6848\u4e8c\u662f\u76ee\u524d\u80fd\u4e00\u673a\u4e24\u7528\u7684\u90a3\u6761\u8def\u3002\u81f3\u4e8e\u201c\u5236\u51b7\u591f\u4e0d\u591f\u201d\uff0c\u4e24\u5957\u90fd\u591f\uff0c\u4e0d\u662f\u51b3\u7b56\u53d8\u91cf\u3002\n    <\/div>\n  <\/section>\n\n  <section id=\"s-faq\">\n    <h2 class=\"sec\">\u5e38\u89c1\u95ee\u9898 <small>\u6210\u4ea4\u524d\u6700\u5e38\u95ee\u7684 6 \u4ef6\u4e8b<\/small><\/h2>\n    <div class=\"faq\">\n      <details>\n        <summary>Q1\uff1a\u7a7a\u8c03\u53ea\u505a\u5236\u51b7\uff0c\u6210\u90fd\u51ac\u5929\u4e0d\u9760\u5b83\u884c\u4e0d\u884c\uff1f<\/summary>\n        <div class=\"a\">A\uff1a\u884c\uff0c\u800c\u4e14\u8fd9\u662f\u66f4\u5408\u7406\u7684\u5206\u5de5\u3002\u6210\u90fd\u51ac\u5b63\u5ba4\u5916\u591a\u5728 0 \u5230 8 \u6444\u6c0f\u5ea6\uff0c\u91c7\u6696\u9700\u6c42\u96c6\u4e2d\u5728 12 \u6708\u5230 2 \u6708\u3002\u5730\u6696\u7528 35 \u5230 45 \u6444\u6c0f\u5ea6\u7684\u4f4e\u6e29\u6c34\u5faa\u73af\uff0c\u70ed\u91cf\u4ece\u5730\u9762\u5f80\u4e0a\u8f90\u5c04\uff0c\u811a\u6696\u5934\u51c9\uff0c\u6ca1\u6709\u5439\u98ce\u611f\uff0c\u4e5f\u6ca1\u6709\u5316\u971c\u505c\u673a\u3002\u7a7a\u8c03\u5236\u70ed\u9760\u9001\u70ed\u98ce\uff0c\u70ed\u7a7a\u6c14\u4f1a\u6d6e\u5728\u623f\u95f4\u4e0a\u90e8\uff0c\u5bb9\u6613\u51fa\u73b0\u5934\u70ed\u811a\u51b7\uff1b\u5ba4\u5916\u673a\u7ed3\u971c\u65f6\u8981\u53cd\u5411\u5316\u971c\uff0c\u5316\u971c\u90a3\u51e0\u5206\u949f\u5ba4\u5185\u662f\u505c\u98ce\u7684\u3002\u6240\u4ee5\u672c\u6848\u628a 3 \u4e2a\u6708\u7684\u91c7\u6696\u4ea4\u7ed9\u5730\u6696\uff0c\u7a7a\u8c03\u8d1f\u8d23\u590f\u5b63 3 \u4e2a\u6708\u7684\u5236\u51b7\uff0c\u4ee5\u53ca\u6625\u79cb\u8fc7\u6e21\u5b63\u5076\u5c14\u964d\u6e29\u65f6\u7684\u77ed\u65f6\u4f7f\u7528\u3002\u4e24\u6761\u7cfb\u7edf\u5404\u505a\u5404\u7684\u64c5\u957f\u9879\uff0c\u4f53\u9a8c\u548c\u80fd\u8017\u90fd\u66f4\u597d\u3002<\/div>\n      <\/details>\n      <details>\n        <summary>Q2\uff1a\u8fde\u63a5\u7387 120.8% \u4f1a\u4e0d\u4f1a\u5e26\u4e0d\u52a8\uff1f<\/summary>\n        <div class=\"a\">A\uff1a\u4e0d\u4f1a\u3002\u8fde\u63a5\u7387\u662f\u56db\u53f0\u5185\u673a\u989d\u5b9a\u5236\u51b7\u91cf\u4e4b\u548c 15.1 \u5343\u74e6\uff0c\u9664\u4ee5\u4e3b\u673a\u989d\u5b9a\u5236\u51b7\u91cf 12.5 \u5343\u74e6\uff0c\u7b49\u4e8e 120.8%\uff0c\u5728\u6c1f\u673a 90% \u5230 130% \u7684\u5408\u7406\u533a\u95f4\u5185\u3002\u8fd9\u4e2a\u6bd4\u503c\u9ad8\u4e8e 1 \u7684\u524d\u63d0\u662f\u5404\u623f\u95f4\u4e0d\u4f1a\u540c\u65f6\u6ee1\u8f7d\uff1a\u767d\u5929\u4ee5\u5ba2\u9910\u5385\u53a8\u623f\u4e3a\u4e3b\uff0c\u591c\u95f4\u4ee5\u4e09\u95f4\u5367\u5ba4\u4e3a\u4e3b\uff0c\u5b9e\u9645\u540c\u5f00\u7387\u901a\u5e38\u5728 60% \u5230 80%\u3002\u9700\u8981\u63d0\u9192\u7684\u662f\uff0c\u5982\u679c\u590f\u5929\u508d\u665a\u5ba2\u5385\u548c\u4e09\u4e2a\u5367\u5ba4\u540c\u65f6\u5168\u5f00\u3001\u4e14\u90fd\u8bbe\u5230\u5f88\u4f4e\u7684\u6e29\u5ea6\uff0c\u7cfb\u7edf\u4f1a\u628a\u80fd\u529b\u4f18\u5148\u5206\u914d\u7ed9\u6b63\u5728\u4f7f\u7528\u7684\u623f\u95f4\uff0c\u4e0d\u4f1a\u505c\u673a\uff0c\u4f46\u964d\u6e29\u901f\u5ea6\u4f1a\u6bd4\u5355\u5f00\u65f6\u6162\u4e00\u4e9b\u3002\u8fd9\u662f 125 \u4e3b\u673a\u7684\u6b63\u5e38\u8868\u73b0\uff0c\u4e0d\u662f\u6545\u969c\u3002<\/div>\n      <\/details>\n      <details>\n        <summary>Q3\uff1a\u513f\u7ae5\u623f 8 \u5e73\u65b9\u7c73\u914d 22 \u578b\uff0c\u4f1a\u4e0d\u4f1a\u592a\u5927\u3001\u4f1a\u4e0d\u4f1a\u592a\u51b7\uff1f<\/summary>\n        <div class=\"a\">A\uff1a\u4e0d\u4f1a\u592a\u51b7\u300222 \u578b\u662f\u65e5\u7acb\u4e00\u62d6\u591a\u7cfb\u7edf\u91cc\u6700\u5c0f\u7684\u6807\u51c6\u5185\u673a\uff0c8 \u5e73\u65b9\u7c73\u6309 220 \u74e6\u6bcf\u5e73\u65b9\u7c73\u7684\u4e0a\u9650\u7b97\u4e5f\u53ea\u9700\u8981 1.76 \u5343\u74e6\uff0c\u914d 22 \u578b\u662f\u5c31\u8fd1\u53d6\u6574\u7684\u5fc5\u7136\u7ed3\u679c\uff0c\u4e0d\u662f\u523b\u610f\u914d\u5927\u3002\u5b9e\u9645\u4f7f\u7528\u4e2d\uff0c\u623f\u95f4\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6\u540e\u4e3b\u673a\u4f1a\u81ea\u52a8\u964d\u9891\uff0c\u5185\u673a\u7684\u7535\u5b50\u81a8\u80c0\u9600\u540c\u6b65\u6536\u5c0f\uff0c\u8f93\u51fa\u8fdc\u4f4e\u4e8e\u989d\u5b9a\u503c\u3002\u771f\u6b63\u8981\u907f\u514d\u7684\u662f\u53e6\u4e00\u4ef6\u4e8b\uff1a\u4e0d\u8981\u4e3a\u4e86\u7701\u51e0\u767e\u5143\u628a 8 \u5e73\u65b9\u7c73\u914d\u5230\u6ca1\u6709\u66f4\u5c0f\u673a\u578b\u53ef\u9009\u7684\u56f0\u5883\u91cc\uff0c\u4e5f\u4e0d\u8981\u56e0\u4e3a\u673a\u5668\u5927\u5c31\u957f\u671f\u628a\u6e29\u5ea6\u8bbe\u5230 22 \u5ea6\u4ee5\u4e0b\uff0c\u90a3\u624d\u4f1a\u89c9\u5f97\u51b7\u3002\u8bbe\u5b9a 26 \u5ea6\u52a0\u81ea\u52a8\u98ce\uff0c\u4f53\u611f\u6700\u8212\u670d\u3002<\/div>\n      <\/details>\n      <details>\n        <summary>Q4\uff1a\u8212\u4eab\u548c\u5c0a\u777f\u5168\u6548\u5dee\u4e00\u4e07\u56db\uff0c\u5230\u5e95\u5dee\u5728\u54ea\uff1f<\/summary>\n        <div class=\"a\">A\uff1a\u5dee\u5728\u4e09\u4ef6\u4e8b\uff0c\u90fd\u4e0d\u662f\u57fa\u7840\u5236\u51b7\u80fd\u529b\u3002\u7b2c\u4e00\u662f\u9664\u6e7f\u65b9\u5f0f\uff1a\u5c0a\u777f\u5168\u6548\u662f\u4e09\u7ba1\u5236\uff0c\u53ef\u4ee5\u5728 18 \u6444\u6c0f\u5ea6\u4e0d\u964d\u6e29\u7684\u60c5\u51b5\u4e0b\u9664\u6e7f\uff0c\u8212\u4eab\u662f\u964d\u6e29\u9664\u6e7f\uff0c\u9664\u6e7f\u65f6\u623f\u95f4\u4f1a\u8ddf\u7740\u53d8\u51c9\uff1b\u7b2c\u4e8c\u662f\u51c0\u5316\u5c42\u7ea7\uff1a\u5c0a\u777f\u5168\u6548\u51fa\u5382\u81ea\u5e26\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0c\u542b PE+ \u51c0\u5316\u3001\u81ea\u6e05\u6d01\u4e0e 60 \u6444\u6c0f\u5ea6\u9664\u83cc\uff0c\u8212\u4eab\u8981\u53e6\u914d PE \u6a21\u5757\u624d\u80fd\u8fbe\u5230\u63a5\u8fd1\u7684\u6548\u679c\uff1b\u7b2c\u4e09\u662f\u5730\u6696\u63a5\u53e3\uff1a\u5c0a\u777f\u5168\u6548\u53ef\u4ee5\u52a0\u88c5\u6c34\u6a21\u5757\u505a\u5929\u6c1f\u5730\u6c34\uff0c\u4e00\u53f0\u4e3b\u673a\u540c\u65f6\u5e26\u7a7a\u8c03\u548c\u5730\u6696\uff0c\u8212\u4eab\u53ea\u80fd\u53e6\u914d\u71c3\u6c14\u58c1\u6302\u7089\u3002\u5c31\u60a8\u4ee5\u5236\u51b7\u4e3a\u4e3b\u3001\u53c8\u8981\u505a\u5730\u6696\u7684\u60c5\u51b5\u770b\uff0c\u8fd9\u7b14\u5dee\u4ef7\u4e70\u7684\u4e3b\u8981\u662f\u9664\u6e7f\u4f53\u611f\u548c\u5730\u6696\u70ed\u6e90\u7684\u9009\u62e9\u6743\uff0c\u4e0d\u662f\u5236\u51b7\u80fd\u529b\u3002<\/div>\n      <\/details>\n      <details>\n        <summary>Q5\uff1a\u73b0\u5728\u88c5\u7a7a\u8c03\uff0c\u5730\u6696\u8fc7\u4e24\u5e74\u518d\u52a0\u884c\u4e0d\u884c\uff1f<\/summary>\n        <div class=\"a\">A\uff1a\u8981\u5206\u4e24\u4ef6\u4e8b\u8bf4\u3002\u5730\u6696\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u548c\u4e3b\u7ba1\u5fc5\u987b\u4e0e\u88c5\u4fee\u540c\u6b65\u505a\uff0c\u56e0\u4e3a\u76d8\u7ba1\u57cb\u5728\u5730\u9762\u627e\u5e73\u5c42\u91cc\uff0c\u88c5\u4fee\u5b8c\u6210\u540e\u518d\u52a0\u5c31\u8981\u62c6\u5730\u9762\uff0c\u4ee3\u4ef7\u5f88\u5927\u3002\u70ed\u6e90\u53ef\u4ee5\u540e\u5b9a\uff0c\u4f46\u63a5\u53e3\u8981\u73b0\u5728\u7559\uff1a\u9009\u65b9\u6848\u4e00\uff0c\u5c31\u5728\u53a8\u623f\u6216\u751f\u6d3b\u9633\u53f0\u9884\u7559\u71c3\u6c14\u58c1\u6302\u7089\u7684\u4f4d\u7f6e\u3001\u70df\u9053\u5b54\u548c\u71c3\u6c14\u63a5\u53e3\uff1b\u9009\u65b9\u6848\u4e8c\uff0c\u5c31\u8981\u5728\u5916\u673a\u4fa7\u9884\u7559\u6c34\u6a21\u5757\u7684\u5b89\u88c5\u4f4d\u4e0e\u51b7\u5a92\u7ba1\u63a5\u53e3\uff0c\u56e0\u4e3a\u5929\u6c1f\u5730\u6c34\u7684\u6c34\u6a21\u5757\u5fc5\u987b\u4e0e\u4e3b\u673a\u540c\u4e00\u5957\u51b7\u5a92\u7cfb\u7edf\u3002\u6240\u4ee5\u771f\u6b63\u7684\u51b3\u7b56\u70b9\u662f\u4eca\u5929\u9009\u54ea\u53f0\u4e3b\u673a\uff0c\u800c\u4e0d\u662f\u4ee5\u540e\u4e70\u4e0d\u4e70\u9505\u7089\u3002<\/div>\n      <\/details>\n      <details>\n        <summary>Q6\uff1a\u65e5\u7acb\u6bd4\u683c\u529b\u3001\u7f8e\u7684\u8d35\u591a\u5c11\uff0c\u8d35\u5728\u54ea\uff1f<\/summary>\n        <div class=\"a\">A\uff1a\u540c\u6237\u578b\u65e5\u7acb\u7684\u4ef7\u683c\u901a\u5e38\u6bd4\u683c\u529b\u3001\u7f8e\u7684\u9ad8\u7ea6\u767e\u5206\u4e4b\u5341\u5230\u5341\u4e94\uff0c\u6bd4\u5927\u91d1\u4fbf\u5b9c\u767e\u5206\u4e4b\u5341\u4e94\u5230\u4e09\u5341\u4e94\u3002\u8d35\u7684\u90e8\u5206\u4e3b\u8981\u5728\u56db\u4ef6\u4e8b\uff1a\u4e00\u662f\u81ea\u4ea7\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\u4e0e\u4e24\u5343\u7ea7\u7535\u5b50\u81a8\u80c0\u9600\uff0c\u7cfb\u7edf\u5728\u90e8\u5206\u8d1f\u8377\u4e0b\u66f4\u7a33\u3001\u66f4\u7701\u7535\uff1b\u4e8c\u662f\u6807\u914d\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u52a0\u6d6e\u5b50\u5f00\u5173\uff0c\u53cc\u91cd\u9632\u6ce1\u9876\uff1b\u4e09\u662f\u5341\u6444\u6c0f\u5ea6\u4f4e\u6e29\u9664\u6e7f\u4e0e\u4e94\u5341\u516d\u6863\u6e7f\u5ea6\u8c03\u8282\uff0c\u6210\u90fd\u56de\u5357\u5929\u80fd\u7528\uff1b\u56db\u662f\u5185\u673a\u6700\u4f4e\u5341\u4e03\u5206\u8d1d\u7684\u9759\u97f3\u6c34\u5e73\u3002\u8fd9\u56db\u9879\u90fd\u4e0d\u4f53\u73b0\u5728\u5236\u51b7\u91cf\u4e0a\uff0c\u4f46\u51b3\u5b9a\u4e86\u4e94\u5e74\u3001\u5341\u5e74\u540e\u8fd9\u5957\u7cfb\u7edf\u8fd8\u7701\u4e0d\u7701\u5fc3\u3002<\/div>\n      <\/details>\n    <\/div>\n  <\/section>\n\n  <section id=\"s-after\">\n    <h2 class=\"sec\">\u552e\u540e\u4fdd\u969c <small>\u94bb\u77f3\u5b89\u88c5 \u00b7 \u7ba1\u5bb6\u5f0f\u670d\u52a1<\/small><\/h2>\n    <div class=\"consult\">\n      <div class=\"av\">\u4f59<\/div>\n      <div class=\"info\">\n        <b>\u672c\u6848\u987e\u95ee\uff1a\u4f59\u6653\u73b2<\/b>\n        <span>\u9f99\u8109\u6696\u901a \u00b7 \u6696\u901a\u8bbe\u8ba1\u5e08<\/span>\n        <span>\u7535\u8bdd\uff1a130-0811-3409<\/span>\n      <\/div>\n    <\/div>\n    <ul style=\"font-size:14px;margin-top:14px;line-height:1.9;\">\n      <li>\u65e5\u7acb\u6574\u673a\u8d28\u4fdd 5 \u5e74\uff1b\u54c1\u724c\u6708\u6d3b\u52a8\u671f\u95f4\u53ef\u4eab 10 \u5e74\u8d28\u4fdd\uff08<b>\u4ee5\u5f53\u671f\u5382\u5bb6\u653f\u7b56\u4e3a\u51c6\uff0c\u7b7e\u7ea6\u65f6\u4e66\u9762\u786e\u8ba4<\/b>\uff09<\/li>\n      <li>\u94bb\u77f3\u5b89\u88c5\u6807\u51c6\uff1a\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u6838\u9a8c \u2192 \u94dc\u7ba1\u58c1\u539a\u6838\u9a8c \u2192 \u6c2e\u6c14\u4fdd\u62a4\u710a \u2192 \u9690\u853d\u5de5\u7a0b\u9a8c\u6536 \u2192 \u73b0\u573a\u8c03\u8bd5\u6559\u5b66<\/li>\n      <li>\u957f\u671f\u514d\u8d39\u5de1\u68c0\uff0c24 \u5c0f\u65f6\u54cd\u5e94\uff1b\u6bcf\u5e74\u6362\u5b63\u524d\u4e3b\u52a8\u63d0\u9192\u6e05\u6d17\u6ee4\u7f51<\/li>\n      <li>\u9009\u914d PE \u7eaf\u51c0\u751f\u6001\u6a21\u5757\u5c5e\u8017\u6750\uff0c<b>\u5efa\u8bae 12\u201318 \u4e2a\u6708\u66f4\u6362\u4e00\u6b21<\/b>\uff0c\u9f99\u8109\u6309\u6210\u672c\u4ef7\u4f9b\u5e94<\/li>\n      <li>\u82e5\u91c7\u7528\u6c34\u6a21\u5757\u505a\u5730\u6696\uff1a\u6c34\u4fa7\u4e3a\u5c01\u95ed\u56de\u8def\uff0c<b>\u65e0\u9700\u6e05\u6d17\u677f\u6362\u3001\u65e0\u9700\u6c34\u8d28\u5904\u7406<\/b>\uff0c\u53ea\u9700\u6bcf\u5e74\u68c0\u67e5\u6c34\u538b\u4e0e\u8fc7\u6ee4\u5668<\/li>\n    <\/ul>\n    <div class=\"badges\">\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-zuanshi-anzhuang-2026.jpg\" alt=\"\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u6388\u6743\">\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-rili-teyuejingxiao-2026.jpg\" alt=\"\u65e5\u7acb\u7279\u7ea6\u7ecf\u9500\u6388\u6743\">\n      <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-hitachi-gold-jinpai-anzhuang-2024.jpg\" alt=\"\u65e5\u7acb\u91d1\u724c\u5b89\u88c5\u6388\u6743\">\n    <\/div>\n  <\/section>\n\n  <section id=\"s-store\">\n    <h2 class=\"sec\">\u9f99\u8109\u6696\u901a \u00b7 \u95e8\u5e97\u4e0e\u670d\u52a1 <small>\u6b22\u8fce\u5230\u5e97\u4f53\u9a8c \/ \u9884\u7ea6\u514d\u8d39\u52d8\u6d4b<\/small><\/h2>\n    <div class=\"stores\">\n      <div class=\"store-card\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u5e97\">\n        <div class=\"store-info\">\n          <h3>\u5357\u5bcc\u68ee\u5e97<\/h3>\n          <p class=\"addr\">\u25c6 \u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<\/p>\n          <p class=\"tel\">\u260e <a href=\"tel:02886131795\">028-86131795<\/a><\/p>\n        <\/div>\n      <\/div>\n      <div class=\"store-card\">\n        <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u5e97\">\n        <div class=\"store-info\">\n          <h3>\u5317\u5bcc\u68ee\u5e97<\/h3>\n          <p class=\"addr\">\u25c6 \u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u9986 5 \u697c A5135 \u53f7<\/p>\n          <p class=\"tel\">\u260e <a href=\"tel:02865272586\">028-65272586<\/a><\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <p class=\"footnote\">\n    * \u672c\u518c\u6570\u636e\u57fa\u4e8e\u5ba2\u6237\u63d0\u4f9b\u7684\u623f\u578b\u4e0e\u9762\u79ef\u6d4b\u7b97\uff0c\u6700\u7ec8\u9700\u4ee5\u73b0\u573a\u52d8\u6d4b\u590d\u5c3a\u4e0e\u5b9e\u9645\u9009\u578b\u4e3a\u51c6\u3002<br>\n    * \u5177\u4f53\u9700\u7528\u6237\u578b\u3001\u9762\u79ef\u3001\u914d\u7f6e\u5dee\u5f02\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\u3002\n  <\/p>\n\n<\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>LONGMAI \u00b7 \u9f99\u8109\u6696\u901a \u4e2d\u592e\u7a7a\u8c03\u53cc [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-15688","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=15688\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"LONGMAI \u00b7 \u9f99\u8109\u6696\u901a \u4e2d\u592e\u7a7a\u8c03\u53cc [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=15688\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-19T06:12:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-sx-dfs-112160.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688\",\"name\":\"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/rl-kt-wj-sx-dfs-112160.jpg\",\"datePublished\":\"2026-10-19T06:12:43+00:00\",\"dateModified\":\"2026-10-19T06:12:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/rl-kt-wj-sx-dfs-112160.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/rl-kt-wj-sx-dfs-112160.jpg\",\"width\":2529,\"height\":1422},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15688#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=15688","og_locale":"zh_CN","og_type":"article","og_title":"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a","og_description":"LONGMAI \u00b7 \u9f99\u8109\u6696\u901a \u4e2d\u592e\u7a7a\u8c03\u53cc [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=15688","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-19T06:12:44+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-sx-dfs-112160.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"11 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=15688","url":"https:\/\/longmai-nt.com\/?page_id=15688","name":"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=15688#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=15688#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-sx-dfs-112160.jpg","datePublished":"2026-10-19T06:12:43+00:00","dateModified":"2026-10-19T06:12:44+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=15688#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=15688"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=15688#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-sx-dfs-112160.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/rl-kt-wj-sx-dfs-112160.jpg","width":2529,"height":1422},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=15688#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15688"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15688\/revisions"}],"predecessor-version":[{"id":15689,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15688\/revisions\/15689"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15688"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}