{"id":15704,"date":"2026-10-19T22:57:26","date_gmt":"2026-10-19T14:57:26","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=15704"},"modified":"2026-10-20T01:02:59","modified_gmt":"2026-10-19T17:02:59","slug":"%e6%98%8e%e8%a3%85%e6%9a%96%e6%b0%94-20-16-%e7%ae%a1%e5%a4%9f%e5%90%97%ef%bc%9f%e8%83%bd%e5%b8%a6%e5%87%a0%e7%bb%84%e6%9a%96%e6%b0%94%e7%89%87%e3%80%81%e4%bb%80%e4%b9%88%e6%83%85%e5%86%b5%e4%b8%8d","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=15704","title":{"rendered":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528"},"content":{"rendered":"\n<style>\n.lm2016{--navy:#1a365d;--hl:#c05621;--bd:#d9d2c5;--warm:#faf9f7;--th:#f5f1e8;--red:#b91c1c;--blue:#2b6cb0;font-size:16px;line-height:1.85;color:#2d3748}\n.lm2016 p{margin:14px 0}\n.lm2016 h2{font-size:21px;line-height:1.5;color:var(--navy);margin:34px 0 14px;padding-left:12px;border-left:5px solid var(--hl);font-weight:700}\n.lm2016 h3{font-size:17px;color:var(--navy);margin:22px 0 10px;font-weight:700}\n.lm2016 strong{color:var(--navy)}\n.lm2016 .tw{overflow-x:auto;margin:18px 0}\n.lm2016 table{width:100%;border-collapse:collapse;font-size:15px;min-width:560px}\n.lm2016 th{background:var(--th);border:1px solid var(--bd);padding:10px 12px;text-align:left;font-weight:700;color:var(--navy);white-space:nowrap}\n.lm2016 td{border:1px solid var(--bd);padding:10px 12px;vertical-align:top}\n.lm2016 .ok{color:#1f7a45;font-weight:700}\n.lm2016 .no{color:var(--red);font-weight:700}\n.lm2016 .mid{color:var(--hl);font-weight:700}\n.lm2016 .k{background:var(--warm);border:1.5px solid var(--bd);border-radius:10px;padding:16px 20px;margin:20px 0}\n.lm2016 .warn{background:#fff5f5;border-left:5px solid var(--red);border-radius:0 10px 10px 0;padding:16px 20px;margin:20px 0}\n.lm2016 .info{background:#f0f7ff;border-left:5px solid var(--blue);border-radius:0 10px 10px 0;padding:16px 20px;margin:20px 0}\n.lm2016 .lead{background:var(--warm);border:1.5px solid var(--bd);border-radius:12px;padding:20px 22px;margin:20px 0}\n.lm2016 .lead p{margin:8px 0}\n.lm2016 .q{font-weight:700;color:var(--navy);margin:22px 0 6px}\n.lm2016 .a{margin:0 0 6px}\n.lm2016 .num{display:inline-block;width:22px;height:22px;line-height:22px;text-align:center;background:var(--hl);color:#fff;border-radius:50%;font-size:13px;font-weight:700;margin-right:6px}\n.lm2016 ul,.lm2016 ol{margin:12px 0;padding-left:22px}\n.lm2016 li{margin:8px 0}\n.lm2016 .note{font-size:14px;color:#6b7280;margin-top:10px}\n<\/style>\n\n<div class=\"lm2016\">\n<div class=\"lead\">\n<p><strong>\u5148\u7ed9\u7ed3\u8bba\uff1a20-16 \u7ba1\u4e0d\u662f\u4e0d\u80fd\u505a\uff0c\u662f\u8981\u770b\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3002<\/strong><\/p>\n<p>\u4e3b\u7ba1 20 \u7a33\u5b9a\u80fd\u5e26\u7684\u70ed\u91cf\u5927\u7ea6 <strong>4.6kW<\/strong>\uff08\u4e0d\u5230 5kW\uff09\uff0c\u6309 130W\/\u33a1 \u914d\u7247\uff0c\u5dee\u4e0d\u591a\u7b49\u4e8e <strong>\u4e24\u7ec4<\/strong>\u6696\u6c14\u7247\u3001\u8986\u76d6 30~40\u33a1 \u91c7\u6696\u9762\u79ef\u3002\u6240\u4ee5\u2014\u2014<\/p>\n<p>\u00b7 \u53ea\u505a\u4e00\u4e24\u7ec4\u3001\u6216\u8005\u88c5\u5f97\u591a\u4f46\u5e38\u5e74\u53ea\u5f00\u4e00\u4e24\u7ec4 \u2192 <span class=\"ok\">\u53ef\u4ee5\u505a<\/span>\uff0c\u6548\u679c\u7565\u5dee\u4f46\u80fd\u6ee1\u8db3\uff1b<br>\u00b7 \u5168\u5c4b\u4e09\u7ec4\u4ee5\u4e0a\u540c\u65f6\u5f00 \u2192 <span class=\"no\">\u4e0d\u5efa\u8bae\u505a<\/span>\uff0c\u8fdc\u7aef\u5206\u4e0d\u5230\u6c34\u91cf\uff0c\u623f\u95f4\u5230\u4e0d\u4e86\u6e29\u3002<\/p>\n<p>\u5b83\u53ea\u5f71\u54cd<strong>\u6548\u679c<\/strong>\uff0c\u4e0d\u5f71\u54cd<strong>\u5b89\u5168<\/strong>\uff1a\u4e0d\u4f1a\u56e0\u4e3a\u7ba1\u5b50\u7ec6\u5c31\u6f0f\u6c34\u3001\u7206\u7ba1\u3002\u4f60\u8981\u662f\u786e\u8ba4\u63a5\u53d7\u6548\u679c\u4e0a\u7684\u6298\u6263\uff0c\u6211\u4eec\u53ef\u4ee5\u6309\u4f60\u6307\u5b9a\u7684\u505a\uff0c\u7b7e\u4e00\u4efd\u4e13\u9879\u786e\u8ba4\u4e66\u628a\u8fb9\u754c\u5199\u6e05\u695a\u3002<\/p>\n<\/div>\n<p>\u4e0b\u9762\u628a\u300c\u80fd\u5e26\u591a\u5c11\u3001\u4ec0\u4e48\u60c5\u51b5\u80fd\u505a\u3001\u5dee\u5728\u54ea\u3001\u7b7e\u4ec0\u4e48\u300d\u56db\u4ef6\u4e8b\u8bb2\u900f\u3002\u770b\u5b8c\u4f60\u81ea\u5df1\u5c31\u80fd\u5224\u65ad\uff0c\u4e0d\u7528\u7b49\u6211\u4eec\u4e0a\u95e8\u3002<\/p>\n<h2>20-16 \u5230\u5e95\u80fd\u5e26\u591a\u5c11\u70ed\uff1f\u5148\u770b\u7ba1\u5f84\u548c\u6d41\u91cf\u7684\u5173\u7cfb<\/h2>\n<p>20-16 \u6307\u7684\u662f<strong>\u4e3b\u7ba1\u5916\u5f84 20mm\u3001\u652f\u7ba1\u5916\u5f84 16mm<\/strong> \u7684\u7ec6\u7ba1\u8f93\u914d\u3002\u5b83\u548c\u6211\u4eec\u9ed8\u8ba4\u7684 25-20\uff08\u4e3b\u7ba1 25\u3001\u652f\u7ba1 20\uff09\u6bd4\uff0c\u5dee\u7684\u5c31\u662f\u300c\u6bcf\u5c0f\u65f6\u80fd\u9001\u8fc7\u53bb\u591a\u5c11\u6c34\u300d\u3002\n<p><strong>\u5148\u6f84\u6e05\u4e00\u70b9\uff1a\u95ee\u9898\u51fa\u5728\u4e3b\u7ba1 20\uff0c\u4e0d\u5728\u652f\u7ba1 16\u3002<\/strong>\u652f\u7ba1 16 \u662f\u6211\u4eec\u63a5\u672b\u7aef\u6696\u6c14\u7247\u7684\u5e38\u89c4\u505a\u6cd5\uff0c\u672c\u8eab\u6ca1\u6709\u4efb\u4f55\u95ee\u9898\u2014\u2014\u771f\u6b63\u5361\u4f4f\u6c34\u91cf\u7684\u662f\u90a3\u6839\u4ece\u9505\u7089\u51fa\u6765\u3001\u4e00\u8def\u5206\u5230\u5404\u7ec4\u7684\u4e3b\u7ba1\u9053\u3002\u6240\u4ee5\u5224\u65ad\u80fd\u4e0d\u80fd\u7528\uff0c\u53ea\u770b\u4e3b\u7ba1\u90a3\u4e00\u6bb5\u3002<\/p><\/p>\n<div class=\"k\">\n<p><strong>\u4e00\u53e5\u8bdd\u539f\u7406\uff1a<\/strong>\u6696\u6c14\u7247\u7684\u70ed\u91cf\u6765\u81ea\u70ed\u6c34\uff0c\u70ed\u91cf \uff1d \u6d41\u91cf \u00d7 \u4f9b\u56de\u6c34\u6e29\u5dee\u3002\u7ba1\u5f84\u4e00\u7ec6\uff0c\u6d41\u91cf\u5c31\u6709\u4e0a\u9650\uff1b\u800c\u6e29\u5dee\u53c8\u4e0d\u80fd\u65e0\u9650\u62c9\u5927\uff08\u62c9\u592a\u5927\u9505\u7089\u6548\u7387\u4e0b\u964d\u3001\u8fd8\u4f1a\u51b7\u51dd\u4f24\u7089\uff09\uff0c\u4e24\u5934\u4e00\u5361\uff0c<strong>\u8fd9\u6761\u7ba1\u5b50\u80fd\u9001\u7684\u70ed\u91cf\u5c31\u5c01\u9876\u4e86<\/strong>\u3002<\/p>\n<\/div>\n<p>\u6309\u6696\u6c14\u7247\u7684\u9ad8\u6e29\u5de5\u51b5\uff08\u4f9b\u6c34 80\u2103\uff0f\u56de\u6c34 60\u2103\uff0c\u4f9b\u56de\u6c34\u6e29\u5dee 20\u2103\uff09\u6298\u7b97\uff1a<\/p>\n<div class=\"tw\"><table>\n<tr><th>\u4e3b\u7ba1\u89c4\u683c<\/th><th>\u7a33\u5b9a\u80fd\u5e26\u7684\u70ed\u91cf<\/th><th>\u7ea6\u7b49\u4e8e\u51e0\u7ec4\u6696\u6c14\u7247<\/th><th>\u8986\u76d6\u91c7\u6696\u9762\u79ef<\/th><\/tr>\n<tr><td>25-20\uff08\u6211\u4eec\u7684\u6807\u51c6\u914d\u7f6e\uff09<\/td><td>\u7ea6 11.6kW<\/td><td>4~5 \u7ec4<\/td><td>90\u33a1 \u5de6\u53f3\uff0c\u53ef\u5e26\u5168\u5c4b<\/td><\/tr>\n<tr><td><strong>20-16<\/strong><\/td><td><strong>\u7ea6 4.6kW<\/strong>\uff08\u4e0d\u5230 5kW\uff09<\/td><td><strong>2 \u7ec4<\/strong>\uff083 \u7ec4\u5df2\u5230\u4e34\u754c\uff09<\/td><td><strong>30~40\u33a1<\/strong><\/td><\/tr>\n<\/table><\/div>\n<p class=\"note\">\u8bf4\u660e\uff1a\u4ee5\u4e0a\u6309\u6210\u90fd\u5e38\u89c1\u4f4f\u5b85\u3001\u5355\u4e00\u8def\u4e3b\u7ba1\u3001130W\/\u33a1 \u70ed\u8d1f\u8377\u4f30\u7b97\uff0c\u6bcf\u7ec4\u6696\u6c14\u7247\u7ea6\u6298 2.5kW\u300119\u33a1 \u4e0a\u4e0b\u3002\u5c42\u9ad8\u9ad8\u3001\u5916\u5899\u591a\u3001\u7ba1\u8def\u7ed5\u8fdc\u3001\u672b\u7aef\u5728\u8fdc\u7aef\uff0c\u5b9e\u9645\u80fd\u5e26\u7684\u4f1a\u66f4\u5c11\u4e00\u70b9\u3002<strong>\u5982\u679c\u6309\u5730\u6696\u90a3\u79cd 10\u2103 \u6e29\u5dee\u7b97\uff0c\u540c\u4e00\u6761\u7ba1\u5b50\u80fd\u5e26\u7684\u70ed\u91cf\u4f1a\u51cf\u534a<\/strong>\u2014\u2014\u8fd9\u5f20\u8868\u7684\u6570\u4e0d\u80fd\u76f4\u63a5\u5957\u5230\u5730\u6696\u4e0a\u3002<\/p>\n<div class=\"info\">\n<p><strong>\u5f88\u591a\u4eba\u4ee5\u4e3a\u300c\u7ba1\u5b50\u53ea\u5f71\u54cd\u8fd9\u4e00\u7ec4\u6696\u6c14\u7247\u300d\u2014\u2014\u8fd9\u662f\u6700\u5927\u7684\u8bef\u89e3\u3002<\/strong><\/p>\n<p>\u51b3\u5b9a\u591f\u4e0d\u591f\u7684\u662f<strong>\u540c\u65f6\u5f00\u542f\u7684\u603b\u8d1f\u8377<\/strong>\uff0c\u4e0d\u662f\u5355\u7ec4\u5927\u5c0f\u3002\u4f60\u88c5 4 \u7ec4\uff0c\u4f46\u5e73\u65f6\u53ea\u5f00\u5ba2\u5385 1 \u7ec4\uff0c\u4e3b\u7ba1\u91cc\u53ea\u9700\u8981\u9001 1 \u7ec4\u7684\u6c34\uff0c20 \u7ba1\u591f\u7528\uff1b\u4e00\u5230\u8fc7\u5e74\u5168\u5bb6\u90fd\u5f00\uff0c4 \u7ec4\u4e00\u8d77\u62a2\u6c34\uff0c\u6bcf\u6761\u652f\u8def\u5206\u5230\u7684\u6c34\u91cf\u660e\u663e\u53d8\u5c11\uff0c\u8fdc\u7aef\u90a3\u7ec4\u5c31\u4e0d\u70ed\u4e86\u3002<\/p>\n<\/div>\n<h2>\u8fd9\u4e09\u79cd\u60c5\u51b5\uff0c20-16 \u53ef\u4ee5\u505a<\/h2>\n<p>\u53ea\u8981\u7b26\u5408\u4e0b\u9762\u4efb\u4f55\u4e00\u6761\uff0c20 \u7ba1\u57fa\u672c\u80fd\u6ee1\u8db3\u4f7f\u7528\uff0c\u6548\u679c\u4e0a\u7565\u6709\u6298\u6263\uff0c\u4e0d\u5f71\u54cd\u6b63\u5e38\u751f\u6d3b\u3002<\/p>\n<div class=\"tw\"><table>\n<tr><th>\u4f60\u7684\u60c5\u51b5<\/th><th>\u5224\u65ad<\/th><th>\u539f\u56e0<\/th><\/tr>\n<tr><td><strong>\u53ea\u505a\u5c40\u90e8\u91c7\u6696<\/strong><br>\u5ba2\u5385 + \u4e3b\u5367\u4e24\u7ec4\uff0c\u5176\u4f59\u623f\u95f4\u4e0d\u88c5<\/td><td><span class=\"ok\">\u53ef\u4ee5\u505a<\/span><\/td><td>\u603b\u8d1f\u8377\u5c31\u5728 5kW \u4ee5\u5185\uff0c\u6b63\u597d\u5728\u7ba1\u5b50\u7684\u80fd\u529b\u8303\u56f4\u5185<\/td><\/tr>\n<tr><td><strong>\u91c7\u6696\u9762\u79ef\u5c0f<\/strong><br>\u4e00\u5c45\u3001\u5c0f\u4e24\u5c45\uff0c\u226440\u33a1<\/td><td><span class=\"ok\">\u53ef\u4ee5\u505a<\/span><\/td><td>130W\/\u33a1 \u7b97\u4e0b\u6765 5kW \u4ee5\u5185\uff0c\u4e00\u7ec4\u4e3b\u7ba1\u5e26\u5f97\u52a8<\/td><\/tr>\n<tr><td><strong>\u88c5\u5f97\u591a\uff0c\u4f46\u540c\u5f00\u7387\u4f4e<\/strong><br>\u88c5\u4e86 3~4 \u7ec4\uff0c\u65e5\u5e38\u53ea\u5f00 1~2 \u7ec4<\/td><td><span class=\"mid\">\u53ef\u4ee5\u505a\uff0c\u9700\u786e\u8ba4<\/span><\/td><td>\u540c\u65f6\u5f00\u542f\u7684\u8d1f\u8377\u624d\u662f\u771f\u8d1f\u8377\uff1b\u8fd9\u79cd\u7528\u6cd5\u80fd\u6ee1\u8db3\uff0c\u6c14\u8d39\u4f1a\u7565\u9ad8\u4e00\u70b9<\/td><\/tr>\n<\/table><\/div>\n<p>\u7b2c\u4e09\u6761\u8981\u89e3\u91ca\u4e00\u4e0b\uff1a\u5bb6\u91cc\u5e38\u4f4f\u4eba\u53e3\u5c11\u3001\u767d\u5929\u6ca1\u4eba\u3001\u53ea\u665a\u4e0a\u5f00\u5367\u5ba4\uff0c\u8fd9\u79cd\u300c\u5206\u65f6\u5206\u533a\u5f00\u300d\u7684\u7528\u6cd5\uff0c20 \u7ba1\u57fa\u672c\u6491\u5f97\u4f4f\uff08\u524d\u63d0\u662f\u4f60\u786e\u5b9e\u53ea\u5f00\u8fd9\u4e00\u4e24\u7ec4\uff09\u3002<strong>\u4ee3\u4ef7\u662f\u80fd\u8017\u4f1a\u9ad8\u4e00\u70b9<\/strong>\u2014\u2014\u56e0\u4e3a\u6c34\u91cf\u5c11\u3001\u964d\u6e29\u5feb\uff0c\u9505\u7089\u8981\u591a\u70e7\u51e0\u6b21\u624d\u80fd\u628a\u5ba4\u6e29\u9876\u4f4f\uff0c\u540c\u65f6\u7ec6\u7ba1\u7684\u6cbf\u7a0b\u963b\u529b\u5927\uff0c\u5faa\u73af\u6cf5\u8d1f\u62c5\u4e5f\u91cd\u4e00\u4e9b\u3002\u9ad8\u591a\u5c11\u53d6\u51b3\u4e8e\u4f60\u5f00\u51e0\u7ec4\u3001\u7ba1\u8def\u591a\u957f\uff0c\u6ca1\u6cd5\u7ed9\u4e00\u4e2a\u7edf\u4e00\u6570\u5b57\u3002<\/p>\n<h2>\u8fd9\u4e00\u79cd\u60c5\u51b5\uff0c\u6211\u4eec\u4e0d\u5efa\u8bae\uff1a\u5168\u5c4b\u591a\u7ec4\u540c\u65f6\u5f00<\/h2>\n<p>\u4e09\u7ec4\u4ee5\u4e0a\u3001\u800c\u4e14\u4e60\u60ef\u5168\u5c4b\u4e00\u8d77\u5f00\uff08\u6709\u8001\u4eba\u5c0f\u5b69\u7684\u5bb6\u5ead\u5927\u591a\u662f\u8fd9\u6837\uff09\uff0c\u6211\u4eec\u4e0d\u5efa\u8bae\u7528 20-16\u3002\u539f\u56e0\u4e0d\u662f\u300c\u7ba1\u7ec6\u4f1a\u51fa\u4e8b\u300d\uff0c\u662f<strong>\u6c34\u9001\u4e0d\u5230\u8fdc\u7aef<\/strong>\u3002<\/p>\n<div class=\"warn\">\n<p><strong>\u5178\u578b\u75c7\u72b6\uff0c\u4f60\u53ef\u4ee5\u5bf9\u7167\uff1a<\/strong><\/p>\n<p>\u00b7 \u79bb\u9505\u7089\u8fd1\u7684\u5ba2\u5385\u5f88\u70ed\uff0c\u8d8a\u5f80\u91cc\u7684\u5367\u5ba4\u8d8a\u6e29\uff0c\u6700\u672b\u7aef\u90a3\u7ec4\u57fa\u672c\u4e0d\u70eb\u624b\uff1b<br>\u00b7 \u9505\u7089\u9891\u7e41\u542f\u505c\uff1a\u6c34\u9001\u4e0d\u51fa\u53bb\uff0c\u56de\u6c34\u6e29\u5ea6\u5f88\u5feb\u5347\u4e0a\u6765\uff0c\u9505\u7089\u4ee5\u4e3a\u5230\u6e29\u4e86\u5c31\u505c\uff0c\u4e00\u4f1a\u513f\u53c8\u542f\u52a8\uff1b<br>\u00b7 \u4f9b\u6c34\u6e29\u5ea6\u8c03\u5230 70\u2103 \u4e5f\u538b\u4e0d\u4f4f\uff0c\u623f\u95f4\u8fd8\u662f\u5dee 2~3\u2103\uff1b<br>\u00b7 \u628a\u5ba2\u5385\u90a3\u7ec4\u5173\u6389\uff0c\u5367\u5ba4\u53cd\u5012\u70ed\u4e86\u2014\u2014\u8fd9\u5c31\u662f\u5178\u578b\u7684\u6c34\u91cf\u4e0d\u591f\uff0c\u4e0d\u662f\u6696\u6c14\u7247\u5c0f\u4e86\u3002<\/p>\n<\/div>\n<p>\u8fd9\u79cd\u5931\u8d25\u6700\u96be\u53d7\u7684\u5730\u65b9\u5728\u4e8e\uff1a<strong>\u5b83\u4e0d\u662f\u88c5\u9519\u4e86\uff0c\u662f\u8bbe\u8ba1\u65f6\u5c31\u6ce8\u5b9a\u4e86<\/strong>\u3002\u660e\u88c5\u7ba1\u8def\u8d70\u7684\u662f\u6263\u69fd\uff0c\u8fd4\u5de5\u610f\u5473\u7740\u62c6\u69fd\u3001\u91cd\u5e03\u7ba1\u3001\u8865\u5899\u9762\uff0c\u94b1\u548c\u5de5\u671f\u90fd\u8981\u518d\u82b1\u4e00\u904d\uff0c\u8fd8\u672a\u5fc5\u80fd\u56de\u5230\u539f\u6837\u3002\u6240\u4ee5\u6211\u4eec\u7684\u6001\u5ea6\u662f\uff1a\u5b81\u53ef\u5f00\u5de5\u524d\u628a\u8bdd\u8bf4\u96be\u542c\uff0c\u4e5f\u4e0d\u60f3\u8ba9\u4f60\u4f4f\u8fdb\u53bb\u4e4b\u540e\u518d\u8fd4\u5de5\u3002<\/p>\n<h2>20 \u7ba1\u505a\u660e\u88c5\uff0c\u6548\u679c\u5dee\u5728\u54ea\u4e09\u6b65<\/h2>\n<p>\u4e0d\u662f\u300c\u5dee\u4e00\u70b9\u300d\uff0c\u662f\u4e09\u4e2a\u5177\u4f53\u73af\u8282\uff1a<\/p>\n<p><span class=\"num\">1<\/span><strong>\u5347\u6e29\u6162\u3002<\/strong>\u7ba1\u91cc\u5b58\u7684\u6c34\u5c11\uff0c\u70ed\u5bb9\u5c0f\u3002\u65e9\u4e0a\u5f00\u673a\uff0c25 \u7ba1\u5347\u6e29\u660e\u663e\u5feb\u4e00\u4e9b\uff0c20 \u7ba1\u8981\u591a\u7b49\u4e00\u9635\uff0c\u56e0\u4e3a\u6bcf\u5c0f\u65f6\u9001\u8fdb\u6765\u7684\u70ed\u91cf\u672c\u8eab\u5c31\u5c11\u3002<\/p>\n<p><span class=\"num\">2<\/span><strong>\u8fdc\u8fd1\u6e29\u5dee\u5927\u3002<\/strong>\u7ba1\u8d8a\u7ec6\uff0c\u6cbf\u7a0b\u963b\u529b\u8d8a\u5927\uff0c\u538b\u964d\u8d8a\u660e\u663e\u3002\u79bb\u9505\u7089\u8fd1\u7684\u7ec4\u548c\u8fdc\u7aef\u7684\u7ec4\uff0c\u5b9e\u9645\u62ff\u5230\u7684\u6c34\u91cf\u5dee\u5f97\u66f4\u591a\uff0c\u8868\u73b0\u5c31\u662f\u300c\u8fd1\u70ed\u8fdc\u51b7\u300d\u3002<\/p>\n<p><span class=\"num\">3<\/span><strong>\u80fd\u8017\u7565\u9ad8\u3002<\/strong>\u4e3a\u4e86\u9876\u4f4f\u5ba4\u6e29\uff0c\u4f9b\u6c34\u6e29\u5ea6\u8981\u8c03\u9ad8\u3001\u9505\u7089\u4f4e\u8d1f\u8377\u8fd0\u884c\u65f6\u95f4\u53d8\u957f\uff0c\u6c14\u8d39\u4f1a\u6bd4\u540c\u6837\u6237\u578b\u7528 25 \u7ba1\u9ad8\u4e00\u4e9b\u3002\u5e45\u5ea6\u53d6\u51b3\u4e8e\u5f00\u51e0\u7ec4\u3001\u7ba1\u8def\u957f\u77ed\u3001\u623f\u5b50\u4fdd\u6e29\uff0c\u6211\u4eec\u4e0d\u7ed9\u7edf\u4e00\u7684\u767e\u5206\u6bd4\u3002<\/p>\n<p>\u7b2c 2 \u6761\u5982\u679c\u5df2\u7ecf\u53d1\u751f\u4e86\uff0c\u53ef\u4ee5\u770b\u8fd9\u7bc7\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=6528\">\u660e\u88c5\u6696\u6c14\u4e0d\u70ed\u3001\u8fd1\u70ed\u8fdc\u51b7\uff1f\u75c5\u6839\u5728\u8d70\u7ba1\u548c\u6d41\u91cf<\/a>\uff0c\u91cc\u9762\u6709\u6c34\u529b\u5931\u8861\u7684\u5224\u65ad\u65b9\u6cd5\u548c\u5904\u7406\u987a\u5e8f\u3002<\/p>\n<h2>\u53ea\u5f71\u54cd\u6548\u679c\uff0c\u4e0d\u5f71\u54cd\u5b89\u5168\u2014\u2014\u8fd9\u4e00\u70b9\u5fc5\u987b\u8bf4\u6e05<\/h2>\n<p>\u5f88\u591a\u4eba\u4e00\u542c\u300c\u4e0d\u63a8\u8350\u300d\u5c31\u4ee5\u4e3a\u300c\u6709\u5371\u9669\u300d\u3002\u4e0d\u662f\u3002\u7ba1\u5f84\u53ea\u51b3\u5b9a<strong>\u70ed\u9001\u4e0d\u9001\u5f97\u5230<\/strong>\uff0c\u4e0d\u51b3\u5b9a<strong>\u6f0f\u4e0d\u6f0f<\/strong>\u3002<\/p>\n<div class=\"k\">\n<p><strong>\u7528 20-16 \u505a\uff0c\u8fd9\u4e9b\u90fd\u4e0d\u4f1a\u53d8\uff1a<\/strong><\/p>\n<p>\u00b7 \u7ba1\u6750\u8fd8\u662f\u540c\u4e00\u6279\u5408\u683c\u7ba1\u6750\uff0c\u4e0d\u662f\u964d\u7ea7\u6599\uff1b<br>\u00b7 \u6253\u538b\u9a8c\u6536\u8fd8\u662f\u540c\u4e00\u5957\u6807\u51c6\uff0c\u505a\u5b8c\u7167\u5e38\u4fdd\u538b\u3001\u7167\u5e38\u51fa\u9a8c\u6536\u8bb0\u5f55\uff1b<br>\u00b7 \u63a5\u5934\u3001\u9600\u95e8\u3001\u6696\u6c14\u7247\u7684\u65bd\u5de5\u5de5\u827a\u5b8c\u5168\u4e00\u6837\uff1b<br>\u00b7 \u4e0d\u4f1a\u56e0\u4e3a\u7ba1\u5b50\u7ec6\u5c31\u66f4\u5bb9\u6613\u7206\u7ba1\u3001\u6e17\u6f0f\uff0c\u4e5f\u4e0d\u4f1a\u56e0\u6b64\u635f\u574f\u58c1\u6302\u7089\uff1b<br>\u00b7 \u9505\u7089\u6709\u6700\u4f4e\u6d41\u91cf\u4fdd\u62a4\uff0c\u8c03\u8bd5\u65f6\u628a\u5faa\u73af\u6cf5\u6863\u4f4d\u548c\u4f9b\u56de\u6c34\u6e29\u5dee\u8c03\u5230\u4f4d\u5c31\u884c\u3002<\/p>\n<\/div>\n<p>\u6240\u4ee5\u6211\u4eec\u53cd\u5bf9 20-16 \u7684\u7406\u7531<strong>\u53ea\u6709\u4e00\u6761\uff1a\u6548\u679c\u53ef\u80fd\u8fbe\u4e0d\u5230\u4f60\u7684\u9884\u671f<\/strong>\u3002\u81f3\u4e8e\u6750\u6599\u3001\u65bd\u5de5\u8d28\u91cf\u3001\u6e17\u6f0f\u8fd9\u4e9b\uff0c\u6211\u4eec\u8be5\u8d1f\u7684\u8d23\u4e00\u5206\u4e0d\u5c11\u2014\u2014\u8fd9\u4e00\u70b9\u4f1a\u5199\u8fdb\u786e\u8ba4\u4e66\u91cc\uff0c\u540e\u9762 FAQ \u7b2c 8 \u6761\u4e5f\u8bf4\u5f97\u66f4\u76f4\u767d\u3002<\/p>\n<h2>\u65e2\u7136\u80fd\u7528\uff0c\u6211\u4eec\u4e3a\u4ec0\u4e48\u8fd8\u662f\u4e0d\u63a8\u8350<\/h2>\n<p>\u56e0\u4e3a\u597d\u770b\u662f\u771f\u7684\uff0c\u4ee3\u4ef7\u4e5f\u662f\u771f\u7684\u3002<\/p>\n<p>20 \u7ba1\u914d<strong>\u7a84\u578b\u6263\u69fd<\/strong>\uff0c\u69fd\u4f53\u80fd\u6bd4 25 \u7ba1\u7528\u7684\u7a84\u4e00\u4e9b\uff0c\u8d34\u5899\u89d2\u3001\u8d70\u95e8\u5957\u4e0a\u65b9\u66f4\u9690\u5f62\uff0c\u5c24\u5176\u8001\u623f\u4e0d\u60f3\u7834\u574f\u4e73\u80f6\u6f06\u7684\uff0c\u8fd9\u4e2a\u8bf1\u60d1\u5f88\u5927\u3002\u52a0\u4e0a 20-16 \u5728\u62a5\u4ef7\u91cc<strong>\u6bcf\u7ec4\u8fd8\u4fbf\u5b9c 100 \u5143<\/strong>\uff08\u5dee\u4ef7\u4ec5\u4e3a\u914d\u7f6e\u5bf9\u6bd4\u793a\u4f8b\uff0c\u6700\u7ec8\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u6e05\u5355\u4e3a\u51c6\uff09\uff0c\u770b\u8d77\u6765\u662f\u300c\u53c8\u7701\u53c8\u597d\u770b\u300d\u3002<\/p>\n<p>\u4f46\u6696\u6c14\u8fd9\u4ef6\u4e8b\uff0c\u7b2c\u4e00\u76ee\u7684\u662f\u6696\u548c\u3002\u6211\u4eec\u7684\u9ed8\u8ba4\u914d\u7f6e\u4e00\u76f4\u662f 25-20\uff08\u4e3b\u7ba1 25\u3001\u652f\u7ba1 20\uff09\uff0c\u4e0d\u662f\u56e0\u4e3a\u5b83\u8d35\uff0c\u662f\u56e0\u4e3a\u5b83\u80fd\u5e26\u5168\u5c4b\u3001\u80fd\u4e00\u6b21\u505a\u5bf9\u3002\u7701\u4e0b\u7684\u8fd9 100 \u5143\/\u7ec4\uff0c\u4e00\u65e6\u6548\u679c\u4e0d\u8fbe\u6807\uff0c\u8fd4\u5de5\u62c6\u69fd\u8865\u5899\u7684\u94b1\u662f\u5b83\u7684\u51e0\u5341\u500d\uff0c\u8fd8\u8981\u591a\u4f4f\u534a\u4e2a\u6708\u5de5\u5730\u3002<\/p>\n<p>\u987a\u4fbf\u8bf4\u4e00\u53e5\u516c\u9053\u8bdd\uff1a\u5e02\u9762\u4e0a\u5f88\u591a\u516c\u53f8\u63a8 20 \u7ba1\uff0c\u4e5f\u672a\u5fc5\u662f\u5b58\u5fc3\u7cca\u5f04\u3002\u6709\u7684\u53ea\u505a\u5c40\u90e8\u4e24\u7ec4\uff0c\u672c\u6765\u5c31\u5728 5kW \u4ee5\u5185\uff1b\u6709\u7684\u5728\u5408\u540c\u91cc\u4e0d\u5199\u6548\u679c\u627f\u8bfa\uff0c\u6e29\u5ea6\u591f\u4e0d\u591f\u4e0d\u5728\u4ed6\u7684\u8d23\u4efb\u8303\u56f4\u3002\u771f\u6b63\u7684\u95ee\u9898\u4e0d\u662f\u7ba1\u5b50\uff0c\u662f<strong>\u6709\u6ca1\u6709\u4eba\u66ff\u4f60\u7b97\u8fc7\u8fd9\u4e2a\u623f\u5b50\u5230\u5e95\u9700\u8981\u591a\u5c11\u70ed\u91cf<\/strong>\u3002\u6211\u4eec\u505a\u7684\u662f\u5148\u7b97\u8d1f\u8377\uff0c\u518d\u5b9a\u7ba1\u5f84\u2014\u2014\u7b97\u5b8c\u53d1\u73b0 20 \u7ba1\u591f\uff0c\u6211\u4eec\u7167\u6837\u7ed9\u4f60\u505a\u3002<\/p>\n<h2>\u4f60\u6267\u610f\u8981\u505a\uff0c\u6211\u4eec\u4f1a\u600e\u4e48\u505a<\/h2>\n<p>\u4e0d\u62d2\u7edd\uff0c\u4f46\u6d41\u7a0b\u4f1a\u591a\u4e09\u6b65\uff0c\u76ee\u7684\u53ea\u6709\u4e00\u4e2a\uff1a\u628a\u300c\u80fd\u505a\u5230\u4ec0\u4e48\u7a0b\u5ea6\u300d\u63d0\u524d\u5199\u5728\u7eb8\u4e0a\u3002<\/p>\n<p><span class=\"num\">1<\/span><strong>\u5148\u52d8\u6d4b\u7b97\u8d1f\u8377\u3002<\/strong>\u91cf\u9762\u79ef\u3001\u770b\u5916\u5899\u7a97\u3001\u786e\u8ba4\u4f60\u6253\u7b97\u88c5\u51e0\u7ec4\u3001\u5e73\u65f6\u4f1a\u540c\u65f6\u5f00\u51e0\u7ec4\uff0c\u7b97\u51fa\u6765\u662f\u4e0d\u662f\u5728 20 \u7ba1\u7684\u80fd\u529b\u8303\u56f4\u5185\u3002<\/p>\n<p><span class=\"num\">2<\/span><strong>\u628a\u300c\u80fd\u5e26\u51e0\u7ec4\u300d\u5199\u8fdb\u5408\u540c\u3002<\/strong>\u4e0d\u662f\u7b3c\u7edf\u5199\u300c20-16\u300d\uff0c\u800c\u662f\u5199\u6e05\u300c\u4e3b\u7ba1 20 \u652f\u6301\u540c\u65f6\u5f00\u542f X \u7ec4\uff0c\u8d85\u51fa\u540e\u8fdc\u7aef\u6548\u679c\u4e0b\u964d\u300d\u3002\u8fd9\u6761\u6bd4\u4efb\u4f55\u53e3\u5934\u4fdd\u8bc1\u90fd\u6709\u7528\u3002<\/p>\n<p><span class=\"num\">3<\/span><strong>\u7b7e\u300a20-16 \u8f93\u914d\u7cfb\u7edf\u4e13\u9879\u786e\u8ba4\u4e66\u300b\u3002<\/strong>\u8303\u56f4\u5199\u660e\u767d\uff1a<\/p>\n<div class=\"tw\"><table>\n<tr><th>\u786e\u8ba4\u4e66\u91cc\u5199\u4ec0\u4e48<\/th><th>\u5177\u4f53\u5185\u5bb9<\/th><\/tr>\n<tr><td>\u6548\u679c\u65b9\u9762\u7531\u4e1a\u4e3b\u627f\u62c5<\/td><td>\u540c\u65f6\u5f00\u542f\u7ec4\u6570\u8d85\u51fa\u8bbe\u8ba1\u503c\u65f6\uff0c\u8fdc\u7aef\u6696\u6c14\u7247\u4e0d\u70ed\u3001\u623f\u95f4\u6e29\u5ea6\u4e0d\u8fbe\u6807\u7684\uff0c\u7531\u4e1a\u4e3b\u81ea\u884c\u627f\u62c5<\/td><\/tr>\n<tr><td>\u65bd\u5de5\u4e0e\u6750\u6599\u8d28\u4fdd\u7167\u5e38<\/td><td>\u6e17\u6f0f\u3001\u63a5\u5934\u3001\u7ba1\u6750\u3001\u6696\u6c14\u7247\u3001\u58c1\u6302\u7089\u7684\u8d28\u4fdd\u4e0e\u552e\u540e\uff0c\u6309\u6807\u51c6\u6761\u6b3e\u6267\u884c\uff0c\u4e0d\u56e0\u7528 20-16 \u800c\u51cf\u514d<\/td><\/tr>\n<tr><td>\u4e0d\u6d89\u53ca\u5b89\u5168\u8d23\u4efb\u8c41\u514d<\/td><td>\u7ba1\u5f84\u4e0d\u5e26\u6765\u989d\u5916\u5b89\u5168\u98ce\u9669\uff1b\u5982\u56e0\u65bd\u5de5\u8d28\u91cf\u9020\u6210\u95ee\u9898\uff0c\u8d23\u4efb\u4ecd\u5728\u65bd\u5de5\u65b9<\/td><\/tr>\n<tr><td>\u8c03\u6574\u673a\u5236<\/td><td>\u5982\u540e\u671f\u60f3\u6539\u6210 25-20\uff0c\u53ef\u6309\u5b9e\u9645\u5de5\u7a0b\u91cf\u53e6\u884c\u62a5\u4ef7\u6539\u9020<\/td><\/tr>\n<\/table><\/div>\n<p>\u65bd\u5de5\u7167\u505a\uff0c\u8c03\u8bd5\u65f6\u6211\u4eec\u4f1a\u628a\u6cf5\u6863\u3001\u6e29\u5dee\u3001\u5404\u7ec4\u9600\u95e8\u5f00\u5ea6\u8c03\u5230\u4f4d\uff0c\u628a 20 \u7ba1\u7684\u8f93\u914d\u80fd\u529b\u7528\u8db3\u3002\u4ea4\u4ed8\u540e\u7b2c\u4e00\u4e2a\u91c7\u6696\u5b63\uff0c\u6211\u4eec\u4e0a\u95e8\u6d4b\u5404\u623f\u95f4\u7684\u5b9e\u9645\u6e29\u5ea6\uff0c\u6570\u636e\u7ed9\u4f60\u7559\u6863\u2014\u2014\u8fd9\u5957\u623f\u5b50\u7684\u771f\u5b9e\u80fd\u529b\u5230\u5e95\u591a\u5c11\uff0c\u7528\u6570\u5b57\u8bf4\u8bdd\uff0c\u4e0d\u7528\u611f\u89c9\u8bf4\u8bdd\u3002<\/p>\n<div class=\"info\">\n<p>\u4ef7\u683c\u548c\u5957\u9910\u5728\u8fd9\u91cc\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=13971\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u5957\u9910\u4ef7\u683c\u8868<\/a>\u3002\u7ba1\u9053\u4e09\u6863\u7684\u53e3\u5f84\uff0825-20 \u6807\u51c6\u300132-20 \u52a0\u4ef7\u300120-16 \u51cf\u4ef7\uff09\u4e5f\u5728\u90a3\u5f20\u8868\u91cc\u3002<\/p>\n<\/div>\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n<p class=\"q\">\u95ee\uff1a20-16 \u7ba1\u6700\u591a\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u6309\u6696\u6c14\u7247\u9ad8\u6e29\u5de5\u51b5\uff0880\/60\u2103\u3001\u6e29\u5dee 20\u2103\uff09\u7b97\uff0c\u4e3b\u7ba1 20 \u7a33\u5b9a\u80fd\u5e26\u7684\u70ed\u91cf\u7ea6 4.6kW\uff08\u4e0d\u5230 5kW\uff09\uff0c\u6309 130W\/\u33a1 \u914d\u7247\uff0c\u7ea6\u7b49\u4e8e\u4e24\u7ec4\u6696\u6c14\u7247\uff0c\u8986\u76d6 30~40\u33a1 \u91c7\u6696\u9762\u79ef\u3002\u4e09\u7ec4\u5df2\u7ecf\u5230\u4e34\u754c\u70b9\uff0c\u80fd\u4e0d\u80fd\u6ee1\u8db3\u8981\u770b\u540c\u65f6\u5f00\u51e0\u7ec4\u3002\u56db\u7ec4\u4ee5\u4e0a\u540c\u65f6\u5f00\uff0c\u4e0d\u5efa\u8bae\u7528 20-16\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a\u6211\u5bb6\u4e09\u7ec4\u6696\u6c14\u7247\uff0c\u7528 20 \u7ba1\u80fd\u70ed\u5417\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u770b\u4f60\u5e73\u65f6\u5f00\u51e0\u7ec4\u3002\u5982\u679c\u5e38\u5e74\u53ea\u5f00\u4e00\u5230\u4e24\u7ec4\uff08\u6bd4\u5982\u53ea\u5f00\u5ba2\u5385\u548c\u4e3b\u5367\uff09\uff0c\u53ef\u4ee5\u6ee1\u8db3\uff0c20 \u7ba1\u5e26\u5f97\u52a8\u3002\u5982\u679c\u4e09\u7ec4\u4e60\u60ef\u5168\u5c4b\u540c\u5f00\uff0c\u4e0d\u5efa\u8bae\u2014\u2014\u6c34\u8981\u5206\u5230\u4e09\u6761\u652f\u8def\uff0c\u6bcf\u6761\u5206\u5230\u7684\u66f4\u5c11\uff0c\u79bb\u9505\u7089\u8fdc\u7684\u90a3\u7ec4\u5bb9\u6613\u70ed\u4e0d\u900f\u3002\u8fd9\u79cd\u60c5\u51b5\u5efa\u8bae\u76f4\u63a5\u7528 25-20\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a20 \u7ba1\u662f\u4e0d\u662f\u5bb9\u6613\u6f0f\u6c34\u3001\u7206\u7ba1\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u4e0d\u662f\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6bcf\u5c0f\u65f6\u80fd\u9001\u591a\u5c11\u6c34\uff0c\u4e0d\u51b3\u5b9a\u4f1a\u4e0d\u4f1a\u6f0f\u3002\u6211\u4eec\u7528\u7684\u7ba1\u6750\u3001\u6253\u538b\u9a8c\u6536\u6807\u51c6\u3001\u63a5\u5934\u5de5\u827a\u548c 25 \u7ba1\u5b8c\u5168\u4e00\u6837\uff0c\u4e0d\u4f1a\u56e0\u4e3a\u7ba1\u5b50\u7ec6\u5c31\u589e\u52a0\u6e17\u6f0f\u6216\u8005\u7206\u7ba1\u7684\u98ce\u9669\uff0c\u4e5f\u4e0d\u4f1a\u56e0\u6b64\u635f\u574f\u58c1\u6302\u7089\u3002\u6211\u4eec\u4e0d\u63a8\u8350 20-16\uff0c\u7406\u7531\u53ea\u6709\u6548\u679c\u8fd9\u4e00\u6761\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a\u7528 20 \u7ba1\uff0c\u6c14\u8d39\u4f1a\u9ad8\u591a\u5c11\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u4f1a\u6bd4\u540c\u6237\u578b\u7528 25 \u7ba1\u9ad8\u4e00\u4e9b\uff0c\u4f46\u6ca1\u6cd5\u7ed9\u4e00\u4e2a\u7edf\u4e00\u767e\u5206\u6bd4\u2014\u2014\u5f00\u51e0\u7ec4\u3001\u7ba1\u8def\u591a\u957f\u3001\u623f\u5b50\u4fdd\u6e29\u3001\u8bbe\u5b9a\u6e29\u5ea6\u90fd\u4f1a\u5f71\u54cd\u3002\u539f\u56e0\u6709\u4e24\u4e2a\uff1a\u4e00\u662f\u6c34\u91cf\u5c11\u3001\u964d\u6e29\u5feb\uff0c\u9505\u7089\u8981\u591a\u70e7\u51e0\u6b21\u624d\u9876\u5f97\u4f4f\u5ba4\u6e29\uff1b\u4e8c\u662f\u7ec6\u7ba1\u6cbf\u7a0b\u963b\u529b\u5927\uff0c\u5faa\u73af\u6cf5\u8d1f\u62c5\u66f4\u91cd\u3002\u5982\u679c\u662f\u5c40\u90e8\u91c7\u6696\u3001\u540c\u5f00\u7387\u4f4e\uff0c\u591a\u51fa\u6765\u7684\u90e8\u5206\u901a\u5e38\u4e0d\u5927\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a\u5df2\u7ecf\u88c5\u4e86 20-16\uff0c\u73b0\u5728\u6709\u7684\u623f\u95f4\u4e0d\u70ed\uff0c\u600e\u4e48\u529e\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u5148\u522b\u6025\u7740\u62c6\u7ba1\uff0c\u6309\u8fd9\u4e2a\u987a\u5e8f\u6392\u67e5\uff1a\u2460 \u6838\u5bf9\u662f\u4e0d\u662f\u540c\u65f6\u5f00\u7684\u7ec4\u6570\u8d85\u51fa\u4e86\u8bbe\u8ba1\u503c\uff1b\u2461 \u628a\u8fd1\u7aef\u51e0\u7ec4\u7684\u9600\u95e8\u5f00\u5ea6\u5173\u5c0f\u4e00\u70b9\uff0c\u628a\u6c34\u91cf\u5f80\u8fdc\u7aef\u5300\uff08\u6c34\u529b\u5e73\u8861\uff09\uff1b\u2462 \u8c03\u5faa\u73af\u6cf5\u6863\u4f4d\u548c\u4f9b\u56de\u6c34\u6e29\u5dee\uff1b\u2463 \u68c0\u67e5\u8fdc\u7aef\u662f\u5426\u6709\u6c14\u5835\uff0c\u6392\u6c14\u540e\u518d\u770b\u3002\u505a\u5b8c\u8fd9\u56db\u6b65\u8fd8\u4e0d\u884c\uff0c\u624d\u662f\u7ba1\u8def\u80fd\u529b\u7684\u95ee\u9898\u3002\u53ef\u4ee5\u5148\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=6528\">\u660e\u88c5\u6696\u6c14\u4e0d\u70ed\u3001\u8fd1\u70ed\u8fdc\u51b7\uff1f\u75c5\u6839\u5728\u8d70\u7ba1\u548c\u6d41\u91cf<\/a>\u8fd9\u7bc7\u81ea\u67e5\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a20-16 \u548c 25-20 \u5dee\u591a\u5c11\u94b1\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u7ba1\u9053\u8fd9\u4e00\u9879\uff0c20-16 \u662f\u6bcf\u7ec4\u51cf 100 \u5143\uff0c25-20 \u662f\u6807\u51c6\u914d\u7f6e\u4e0d\u52a0\u94b1\uff0c32-20 \u662f\u6bcf\u7ec4\u52a0 100 \u5143\u3002\u6240\u4ee5\u9009 20-16 \u6bcf\u7ec4\u80fd\u7701 100 \u5143\u3002\u6211\u4eec\u4e0d\u5efa\u8bae\u4e3a\u4e86\u8fd9 100 \u5143\u727a\u7272\u6548\u679c\u2014\u2014\u771f\u8fd4\u5de5\u62c6\u69fd\u8865\u5899\uff0c\u82b1\u8d39\u662f\u5b83\u7684\u51e0\u5341\u500d\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a\u4e3a\u4ec0\u4e48\u6709\u7684\u88c5\u4fee\u516c\u53f8\u8bf4 20 \u7ba1\u5b8c\u5168\u6ca1\u95ee\u9898\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u6709\u4e24\u79cd\u60c5\u51b5\u3002\u4e00\u79cd\u662f\u4ed6\u53ea\u505a\u5c40\u90e8\u4e00\u4e24\u7ec4\uff0c\u672c\u6765\u5c31\u5728 5kW \u4ee5\u5185\uff0c\u786e\u5b9e\u591f\u7528\uff1b\u53e6\u4e00\u79cd\u662f\u5408\u540c\u91cc\u4e0d\u542b\u6548\u679c\u627f\u8bfa\uff0c\u6e29\u5ea6\u591f\u4e0d\u591f\u4e0d\u5199\u8fdb\u6761\u6b3e\u3002\u8fd9\u4e0d\u662f\u7ba1\u5b50\u7684\u95ee\u9898\uff0c\u662f\u6709\u6ca1\u6709\u4eba\u66ff\u4f60\u7b97\u8fc7\u8fd9\u4e2a\u623f\u5b50\u5230\u5e95\u9700\u8981\u591a\u5c11\u70ed\u91cf\u3002\u6211\u4eec\u575a\u6301\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002<\/p>\n<p class=\"q\">\u95ee\uff1a\u7b7e\u4e86\u514d\u8d23\u534f\u8bae\uff0c\u51fa\u4e86\u95ee\u9898\u4f60\u4eec\u5c31\u4e0d\u7ba1\u4e86\u5417\uff1f<\/p>\n<p class=\"a\">\u7b54\uff1a\u4e0d\u662f\u3002\u786e\u8ba4\u4e66\u53ea\u9488\u5bf9\u4e00\u4ef6\u4e8b\uff1a\u540c\u65f6\u5f00\u542f\u7ec4\u6570\u8d85\u51fa\u8bbe\u8ba1\u503c\u65f6\uff0c\u8fdc\u7aef\u623f\u95f4\u6e29\u5ea6\u8fbe\u4e0d\u5230\u7ea6\u5b9a\uff0c\u8fd9\u90e8\u5206\u6548\u679c\u7531\u4e1a\u4e3b\u627f\u62c5\u3002\u6e17\u6f0f\u3001\u63a5\u5934\u3001\u7ba1\u6750\u3001\u6696\u6c14\u7247\u3001\u58c1\u6302\u7089\u7684\u8d28\u4fdd\u548c\u552e\u540e\uff0c\u6309\u6807\u51c6\u6761\u6b3e\u7167\u5e38\u6267\u884c\uff0c\u4e00\u5206\u4e0d\u5c11\u3002\u7ba1\u5f84\u672c\u8eab\u4e0d\u6d89\u53ca\u5b89\u5168\u8d23\u4efb\u8c41\u514d\u2014\u2014\u5982\u679c\u662f\u65bd\u5de5\u8d28\u91cf\u9020\u6210\u7684\u95ee\u9898\uff0c\u8d23\u4efb\u4ecd\u7136\u5728\u6211\u4eec\u3002<\/p>\n<h2>\u627e\u9f99\u8109\u6696\u901a\uff0c\u5148\u7b97\u6e05\u695a\u518d\u51b3\u5b9a<\/h2>\n<p>\u62ff\u4e0d\u51c6\u81ea\u5bb6\u8be5\u7528 20-16 \u8fd8\u662f 25-20\uff0c\u6700\u7701\u4e8b\u7684\u529e\u6cd5\u662f\u8ba9\u6211\u4eec\u5148\u7b97\u4e00\u904d\u8d1f\u8377\uff0c\u4e0d\u6536\u8d39\uff0c\u4e5f\u4e0d\u7528\u4f60\u5148\u5b9a\u65b9\u6848\u3002\u7b97\u5b8c\u5982\u679c 20 \u7ba1\u591f\u7528\uff0c\u6211\u4eec\u4f1a\u76f4\u63a5\u544a\u8bc9\u4f60\u591f\u7528\u3002<\/p>\n<p><strong>\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97\uff09<\/strong>\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348\uff0c\u7535\u8bdd <a href=\"tel:02886131795\">028-86131795<\/a><\/p>\n<p><strong>\u6210\u534e\u533a\u5e97\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986\uff09<\/strong>\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7\uff0c\u7535\u8bdd <a href=\"tel:02865272586\">028-65272586<\/a><\/p>\n<p>\u670d\u52a1\u8303\u56f4\uff1a\u6210\u90fd\u4e3b\u57ce\u533a\u53ca\u53cc\u6d41\u3001\u9f99\u6cc9\u3001\u90eb\u90fd\u3001\u65b0\u90fd\u3001\u9752\u767d\u6c5f\u3001\u5f6d\u5c71\u7b49\u5468\u8fb9\u533a\u53bf\uff0c\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002<\/p>\n<h2>\u63a5\u7740\u5f80\u4e0b\u770b<\/h2>\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13971\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u5957\u9910\u4ef7\u683c\u8868<\/a>\u2014\u2014\u591a\u5c11\u94b1\u3001\u5305\u4ec0\u4e48\u3001\u7ba1\u9053\u4e09\u6863\u600e\u4e48\u9009<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=13800\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\uff5c\u516d\u79cd\u7ba1\u8def+\u56db\u8981\u7d20\u89e3\u6cd5+\u771f\u5b9e\u6848\u4f8b<\/a>\u2014\u2014\u7ba1\u8def\u600e\u4e48\u8d70\u3001\u56db\u8981\u7d20\u600e\u4e48\u914d<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=6528\">\u660e\u88c5\u6696\u6c14\u4e0d\u70ed\u3001\u8fd1\u70ed\u8fdc\u51b7\uff1f\u75c5\u6839\u5728\u8d70\u7ba1\u548c\u6d41\u91cf<\/a>\u2014\u2014\u5df2\u7ecf\u4e0d\u70ed\u7684\u6392\u67e5\u987a\u5e8f<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=15413\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u65bd\u5de5\u5b89\u88c5\u8c03\u8bd5\u9a8c\u6536\u5168\u6d41\u7a0b\uff5c\u6253\u538b\u3001\u58c1\u6302\u7089\u9a8c\u6536\u6807\u51c6<\/a>\u2014\u2014\u6253\u538b\u3001\u9a8c\u6536\u600e\u4e48\u505a<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12447\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66\uff1a\u70ed\u6e90\u9009\u578b\/\u7cfb\u7edf\u8bbe\u8ba1\/\u65bd\u5de5\u9a8c\u6536\/20 \u5e74\u6210\u672c\u5168\u89e3<\/a>\u2014\u2014\u7cfb\u7edf\u5c42\u9762\u7684\u5b8c\u6574\u7248<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u6848\u4f8b\u4e2d\u5fc3<\/a>\u2014\u2014\u660e\u88c5\u6696\u6c14\u5b8c\u5de5\u5b9e\u62cd<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=15712\">\u58c1\u6302\u7089\u600e\u4e48\u9009\uff1f\u5148\u5206\u6e05\u300c\u9505\u7089\u54c1\u724c\u300d\u548c\u300c\u6696\u6c14\u7cfb\u7edf\u54c1\u724c\u300d<\/a>\u2014\u2014\u70ed\u6e90\u600e\u4e48\u6311\uff0c\u522b\u53ea\u76ef\u5343\u74e6\u6570<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=15178\">\u6210\u90fd\u91c7\u6696\u600e\u4e48\u9009\uff1a\u65b0\u623f\u5730\u6696\u8fd8\u662f\u8001\u623f\u660e\u88c5\u6696\u6c14\u7247<\/a>\u2014\u2014\u5148\u5b9a\u4f4d\u81ea\u5bb6\u5c5e\u4e8e\u54ea\u4e00\u79cd<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=15567\">\u6210\u90fd\u5bb6\u5ead\u6696\u901a\u9009\u578b\u81ea\u6d4b\uff1a3 \u4e2a\u63d0\u95ee\uff0b\u4f53\u611f 6 \u6761\u5bf9\u53f7\u5165\u5ea7<\/a>\u2014\u2014\u8fd8\u62ff\u4e0d\u51c6\u5c31\u5148\u505a\u4e00\u904d\u81ea\u6d4b<\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5148\u7ed9\u7ed3\u8bba\uff1a20-16 \u7ba1\u4e0d\u662f\u4e0d\u80fd\u505a\uff0c\u662f\u8981 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-15704","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f\u4e3b\u7ba1 20 \u7a33\u5b9a\u7ea6 4.6kW\uff0c\u7b49\u4e8e\u4e24\u7ec4\u300130~40\u33a1\u3002\u53ea\u505a\u5c40\u90e8\u6216\u540c\u5f00\u7387\u4f4e\u53ef\u4ee5\u505a\uff0c\u5168\u5c4b\u591a\u7ec4\u540c\u5f00\u4e0d\u5efa\u8bae\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6548\u679c\u4e0d\u5f71\u54cd\u5b89\u5168\uff0c\u6210\u90fd\u9f99\u8109\u6696\u901a\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=15704\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f\u4e3b\u7ba1 20 \u7a33\u5b9a\u7ea6 4.6kW\uff0c\u7b49\u4e8e\u4e24\u7ec4\u300130~40\u33a1\u3002\u53ea\u505a\u5c40\u90e8\u6216\u540c\u5f00\u7387\u4f4e\u53ef\u4ee5\u505a\uff0c\u5168\u5c4b\u591a\u7ec4\u540c\u5f00\u4e0d\u5efa\u8bae\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6548\u679c\u4e0d\u5f71\u54cd\u5b89\u5168\uff0c\u6210\u90fd\u9f99\u8109\u6696\u901a\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=15704\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-19T17:02:59+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15704\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15704\",\"name\":\"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-10-19T14:57:26+00:00\",\"dateModified\":\"2026-10-19T17:02:59+00:00\",\"description\":\"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f\u4e3b\u7ba1 20 \u7a33\u5b9a\u7ea6 4.6kW\uff0c\u7b49\u4e8e\u4e24\u7ec4\u300130~40\u33a1\u3002\u53ea\u505a\u5c40\u90e8\u6216\u540c\u5f00\u7387\u4f4e\u53ef\u4ee5\u505a\uff0c\u5168\u5c4b\u591a\u7ec4\u540c\u5f00\u4e0d\u5efa\u8bae\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6548\u679c\u4e0d\u5f71\u54cd\u5b89\u5168\uff0c\u6210\u90fd\u9f99\u8109\u6696\u901a\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15704#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15704\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15704#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528 - \u9f99\u8109\u6696\u901a","description":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f\u4e3b\u7ba1 20 \u7a33\u5b9a\u7ea6 4.6kW\uff0c\u7b49\u4e8e\u4e24\u7ec4\u300130~40\u33a1\u3002\u53ea\u505a\u5c40\u90e8\u6216\u540c\u5f00\u7387\u4f4e\u53ef\u4ee5\u505a\uff0c\u5168\u5c4b\u591a\u7ec4\u540c\u5f00\u4e0d\u5efa\u8bae\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6548\u679c\u4e0d\u5f71\u54cd\u5b89\u5168\uff0c\u6210\u90fd\u9f99\u8109\u6696\u901a\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=15704","og_locale":"zh_CN","og_type":"article","og_title":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528 - \u9f99\u8109\u6696\u901a","og_description":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f\u4e3b\u7ba1 20 \u7a33\u5b9a\u7ea6 4.6kW\uff0c\u7b49\u4e8e\u4e24\u7ec4\u300130~40\u33a1\u3002\u53ea\u505a\u5c40\u90e8\u6216\u540c\u5f00\u7387\u4f4e\u53ef\u4ee5\u505a\uff0c\u5168\u5c4b\u591a\u7ec4\u540c\u5f00\u4e0d\u5efa\u8bae\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6548\u679c\u4e0d\u5f71\u54cd\u5b89\u5168\uff0c\u6210\u90fd\u9f99\u8109\u6696\u901a\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=15704","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-19T17:02:59+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=15704","url":"https:\/\/longmai-nt.com\/?page_id=15704","name":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-10-19T14:57:26+00:00","dateModified":"2026-10-19T17:02:59+00:00","description":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\uff1f\u4e3b\u7ba1 20 \u7a33\u5b9a\u7ea6 4.6kW\uff0c\u7b49\u4e8e\u4e24\u7ec4\u300130~40\u33a1\u3002\u53ea\u505a\u5c40\u90e8\u6216\u540c\u5f00\u7387\u4f4e\u53ef\u4ee5\u505a\uff0c\u5168\u5c4b\u591a\u7ec4\u540c\u5f00\u4e0d\u5efa\u8bae\u3002\u7ba1\u5f84\u53ea\u5f71\u54cd\u6548\u679c\u4e0d\u5f71\u54cd\u5b89\u5168\uff0c\u6210\u90fd\u9f99\u8109\u6696\u901a\u5148\u7b97\u8d1f\u8377\u518d\u5b9a\u7ba1\u5f84\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=15704#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=15704"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=15704#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u660e\u88c5\u6696\u6c14 20-16 \u7ba1\u591f\u5417\uff1f\u80fd\u5e26\u51e0\u7ec4\u6696\u6c14\u7247\u3001\u4ec0\u4e48\u60c5\u51b5\u4e0d\u5efa\u8bae\u7528"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15704","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15704"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15704\/revisions"}],"predecessor-version":[{"id":15715,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15704\/revisions\/15715"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15704"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}