{"id":15911,"date":"2026-10-21T15:35:04","date_gmt":"2026-10-21T07:35:04","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=15911"},"modified":"2026-10-21T18:50:36","modified_gmt":"2026-10-21T10:50:36","slug":"%e6%b0%b4%e6%9c%ba%e6%8a%a5%e4%bb%b7%e4%b8%ba%e4%bb%80%e4%b9%88%e5%b7%ae%e8%bf%99%e4%b9%88%e5%a4%9a%ef%bc%9a%e4%b8%83%e9%a1%b9%e5%b7%ae%e4%bb%b7%e9%80%90%e6%9d%a1%e7%ae%97%e7%bb%99%e4%bd%a0%e7%9c%8b","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=15911","title":{"rendered":"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b"},"content":{"rendered":"\n<h2>\u5148\u7ed9\u7ed3\u8bba\uff1a\u6c34\u673a\u62a5\u4ef7\u5dee\u7684\u662f\u201c\u56db\u672c\u8d26\u201d\uff0c\u4e0d\u662f\u4e3b\u673a<\/h2>\n<p>\u540c\u6837\u6237\u578b\u3001\u540c\u6837\u4e00\u53f0\u4e3b\u673a\uff0c\u4e24\u5bb6\u6c34\u673a\u62a5\u4ef7\u80fd\u5dee\u4e00\u4e24\u4e07\uff0c\u751a\u81f3\u66f4\u591a\u3002\u5ba2\u6237\u5e38\u5e38\u4ee5\u4e3a\u5dee\u4ef7\u5728\u201c\u5546\u5bb6\u8d5a\u591a\u8d5a\u5c11\u201d\uff0c\u5176\u5b9e\u7edd\u5927\u591a\u6570\u5dee\u4ef7\u6765\u81ea\u56db\u672c\u8d26\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u56db\u672c\u8d26<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u91cc\u9762\u88c5\u7684\u662f\u4ec0\u4e48<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u80fd\u4e0d\u80fd\u7701<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2460 \u4e3b\u673a\u4e0e\u5916\u673a\u5b89\u88c5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u673a\u5c31\u4f4d\u3001\u51cf\u632f\u3001\u63a5\u7ba1\u3001\u62bd\u771f\u7a7a\u3001\u8c03\u8bd5\uff1b\u540a\u88c5\u53e6\u8ba1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u80fd\u7701\uff0c\u4f46\u7701\u7684\u662f\u8c03\u8bd5\u548c\u51cf\u632f<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2461 \u7ba1\u9053\u4e0e\u4fdd\u6e29\u6750\u6599<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u7ba1\u3001\u652f\u7ba1\u3001\u4fdd\u6e29\u3001\u9600\u95e8\u3001\u914d\u4ef6<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6700\u80fd\u7701\uff0c\u4e5f\u6700\u770b\u4e0d\u51fa\u6765<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2462 \u672b\u7aef\u914d\u4ef6<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u98ce\u673a\u76d8\u7ba1\u3001\u8f6f\u63a5\u3001\u4e8c\u901a\u9600\u3001\u9600\u67c4\u3001\u63d0\u5347\u6cf5\u3001\u51c0\u5316\u6a21\u5757<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5dee\u5f97\u6700\u72e0\u7684\u662f\u98ce\u673a\u76d8\u7ba1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2463 \u8bbe\u8ba1\u4e0e\u4eba\u5de5\u670d\u52a1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8d1f\u8377\u6838\u7b97\u3001\u6c34\u529b\u5e73\u8861\u3001\u7ba1\u8def\u89c4\u5212\u3001\u76d1\u7406\u3001\u8054\u4fdd\u3001\u8c03\u8bd5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6700\u5bb9\u6613\u88ab\u201c\u514d\u8d39\u8bbe\u8ba1\u201d\u62b9\u6389<\/td><\/tr>\n<\/tbody><\/table>\n<p>\u4e0b\u9762\u9010\u672c\u62c6\u5f00\u7b97\u3002\u6240\u6709\u6570\u5b57\u90fd\u6309\u9f99\u8109\u7684\u5e38\u89c4\u914d\u7f6e\u5217\u51fa\uff0c\u65b9\u4fbf\u4f60\u62ff\u7740\u62a5\u4ef7\u5355\u5bf9\u7167\u2014\u2014<strong>\u4e0d\u662f\u8ba9\u4f60\u6bd4\u8c01\u4fbf\u5b9c\uff0c\u800c\u662f\u8ba9\u4f60\u770b\u61c2\u94b1\u82b1\u5728\u54ea\u3002<\/strong><\/p>\n\n<h2>\u7b2c\u4e00\u672c\u8d26\uff1a\u4e3b\u673a\u4e0e\u5916\u673a\u5b89\u88c5<\/h2>\n<p>\u4e3b\u673a\u672c\u8eab\u7684\u4ef7\u683c\u662f\u900f\u660e\u7684\uff0c\u578b\u53f7\u4e00\u67e5\u5c31\u77e5\u9053\u3002\u771f\u6b63\u6709\u5dee\u522b\u7684\u662f\u5b89\u88c5\u8fd9\u4e00\u6bb5\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u9879\u76ee<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u89c4\u8303\u505a\u6cd5<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7b80\u5316\u505a\u6cd5\u5e38\u89c1\u8868\u73b0<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\uff08\u542b\u6750\u6599\u4e0e\u4eba\u5de5\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">200 \u4e3b\u673a\u4ee5\u5185 3,600 \u5143\/\u5957\uff1b220 \u4ee5\u4e0a 4,000 \u5143\/\u5957\uff1b\u522b\u5885\u9876\u51fa\u98ce 4,200 \u5143\/\u5957<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u786c\u63a5\u4e0d\u7559\u8f6f\u63a5\u3001\u4e0d\u505a\u51cf\u632f\u57ab\u3001\u62bd\u771f\u7a7a\u65f6\u95f4\u538b\u7f29<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5916\u673a\u540a\u88c5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6309\u73b0\u573a\u53e6\u8ba1\uff08\u9ad8\u5c42\u3001\u65e0\u7535\u68af\u3001\u9700\u673a\u68b0\u540a\u88c5\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u62a5\u4ef7\u91cc\u4e0d\u63d0\uff0c\u8fdb\u573a\u540e\u518d\u52a0\u94b1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u673a\u4fa7\u6c34\u6cf5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5b9a\u9891\u6cf5 1,200 \u5143\/\u4e2a\uff0c\u6216\u5347\u7ea7\u4e8c\u6b21\u4fa7\u53d8\u9891\u6cf5 2,200 \u5143\/\u4e2a<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7528\u4f4e\u626c\u7a0b\u6cf5\u51d1\uff0c\u8fdc\u7aef\u70b9\u6d41\u91cf\u4e0d\u591f<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7f13\u51b2\u6c34\u7bb1\uff08\u6309\u9700\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u542b\u65c1\u901a\u7ec4\u4ef6 2,600 \u5143\/\u5957\uff0c\u7cfb\u7edf\u6c34\u91cf\u4e0d\u8db3\u65f6\u624d\u52a0<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e00\u5f8b\u4e0d\u52a0\uff0c\u5c0f\u6c34\u91cf\u7cfb\u7edf\u9891\u7e41\u542f\u505c<\/td><\/tr>\n<\/tbody><\/table>\n<p>\u8fd9\u4e00\u6bb5\u6700\u5bb9\u6613\u51fa\u95ee\u9898\u7684\u662f\u201c\u5916\u673a\u540a\u88c5\u4e0d\u5728\u62a5\u4ef7\u91cc\u201d\u3002\u7b49\u4e3b\u673a\u5230\u4e86\u697c\u4e0b\u3001\u540a\u8f66\u8981\u8fdb\u573a\uff0c\u624d\u53d1\u73b0\u8fd9\u7b14\u94b1\u6ca1\u7b97\u2014\u2014\u8fd9\u65f6\u5019\u6ca1\u6709\u8bae\u4ef7\u7a7a\u95f4\u3002<\/p>\n\n<h2>\u7b2c\u4e8c\u672c\u8d26\uff1a\u7ba1\u9053\u4e0e\u4fdd\u6e29\uff0c\u8fd9\u662f\u5dee\u4ef7\u6700\u5927\u53c8\u6700\u770b\u4e0d\u89c1\u7684\u4e00\u5757<\/h2>\n<p>\u6c34\u673a\u7684\u7ba1\u9053\u548c\u6c1f\u673a\u5b8c\u5168\u4e0d\u662f\u4e00\u56de\u4e8b\u3002\u6c1f\u673a\u662f\u94dc\u7ba1\uff0c\u6807\u51c6\u5316\uff1b\u6c34\u673a\u8d70\u7684\u662f\u6c34\uff0c\u7ba1\u5f84\u3001\u58c1\u539a\u3001\u6750\u8d28\u3001\u4fdd\u6e29\u5bc6\u5ea6\u6837\u6837\u6709\u8bb2\u7a76\u3002\u8fd9\u4e00\u5757\u6309\u201c\u5143\/\u98ce\u76d8\u201d\u8ba1\u4ef7\uff0c\u6309\u4e3b\u673a\u5339\u6570\u9009\u6863\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u4e3b\u673a\u5339\u6570<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7ba1\u5f84\u7ec4\u5408<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7cfb\u7edf\u9009\u6750\u5355\u4ef7<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u5305\u542b<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">5 \u5339\u53ca\u4ee5\u4e0b\uff08\u2264125\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">De40\uff0bDe32\uff0bDe25<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">1,700 \u5143\/\u98ce\u76d8<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\" rowspan=\"4\">\u4e3b\u7ba1\u3001\u652f\u7ba1\u3001\u98ce\u76d8\u9600\u95e8\u3001\u914d\u4ef6\u3001\u4fdd\u6e29<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">6 \u5339\uff08140\uff5e180\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">De50\uff0bDe32\uff0bDe25<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">1,800 \u5143\/\u98ce\u76d8<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">8 \u5339\u53ca\u4ee5\u4e0a\uff08200\uff5e280\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">De50\uff0bDe40\uff0bDe32<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">2,000 \u5143\/\u98ce\u76d8<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">320 \u4ee5\u4e0a<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">De63\uff0bDe40\uff0bDe32<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">2,200 \u5143\/\u98ce\u76d8<\/td><\/tr>\n<\/tbody><\/table>\n<p><strong>\u7ba1\u6750\u672c\u8eab\u6709\u4ef7\u5dee\u3002<\/strong>\u6c34\u673a\u7a7a\u8c03\u4e13\u7528\u7ba1\uff08\u8010\u9ad8\u6e29\u7684 PPR-CT\uff09\u548c\u56fd\u4ea7 PE-Xa \u7ba1\u4e4b\u95f4\uff0c\u5e73\u5747\u6bcf\u53f0\u7ea6\u6709 400 \u5143\u5dee\u4ef7\uff1b\u518d\u770b\u58c1\u539a\uff0c\u6b63\u6807\u548c\u8584\u58c1\u53c8\u662f\u53e6\u4e00\u4e2a\u4ef7\u3002\u8584\u58c1\u7ba1\u521a\u88c5\u4e0a\u770b\u4e0d\u51fa\u95ee\u9898\uff0c\u4e24\u4e09\u5e74\u540e\u627f\u538b\u3001\u8010\u6e29\u7684\u4f59\u91cf\u5c31\u6ca1\u4e86\u3002<\/p>\n<p><strong>\u4fdd\u6e29\u5dee\u4ef7\u66f4\u5927\u3002<\/strong>\u89c4\u8303\u505a\u6cd5\u662f\u6a61\u5851\u4fdd\u6e29 B1 \u7ea7\u300120mm \u539a\uff0c\u4e3b\u7ba1\u652f\u7ba1\u90fd\u8981\u5305\uff0c\u51b7\u51dd\u6c34\u7ba1\u4e5f\u8981\u5305\u3002\u7b80\u5316\u505a\u6cd5\u5e38\u89c1\u4e24\u79cd\uff1a\u4fdd\u6e29\u539a\u5ea6\u51cf\u534a\u3001\u6216\u8005\u53ea\u5305\u4e3b\u7ba1\u4e0d\u5305\u652f\u7ba1\u3002\u6210\u90fd\u590f\u5929\u7ba1\u9053\u8868\u9762\u6e29\u5ea6\u4f4e\uff0c\u4fdd\u6e29\u4e0d\u591f\u5c31\u662f\u51dd\u6c34\uff0c\u6c34\u987a\u7740\u652f\u67b6\u6ef4\u5230\u540a\u9876\u4e0a\u2014\u2014\u8fd9\u662f\u6c34\u673a\u8fd4\u5de5\u91cc\u6700\u5e38\u89c1\u7684\u4e00\u79cd\u3002<\/p>\n<p><strong>\u9600\u95e8\u914d\u4ef6\u4e5f\u5728\u8fd9\u672c\u8d26\u91cc\u3002<\/strong>\u89c4\u8303\u914d\u7f6e\u5305\u62ec\uff1a\u7535\u70ed\u4e8c\u901a\u9600\u3001\u538b\u5dee\u65c1\u901a\u9600\u3001\u81ea\u52a8\u6392\u6c14\u9600\u3001\u81ea\u52a8\u8865\u6c34\u9600\u3001\u5b89\u5168\u9600\u3002\u8fd9\u4e9b\u540d\u5b57\u5ba2\u6237\u542c\u4e0d\u61c2\uff0c\u4f46\u5c11\u4e00\u4e2a\u5c31\u4f1a\u51fa\u95ee\u9898\uff1a\u6ca1\u6709\u81ea\u52a8\u6392\u6c14\u9600\uff0c\u7cfb\u7edf\u618b\u6c14\u3001\u5c40\u90e8\u4e0d\u70ed\uff1b\u6ca1\u6709\u538b\u5dee\u65c1\u901a\u9600\uff0c\u672b\u7aef\u5173\u5c0f\u65f6\u6c34\u6cf5\u618b\u538b\u3002<\/p>\n\n<h2>\u7b2c\u4e09\u672c\u8d26\uff1a\u672b\u7aef\u914d\u4ef6\uff0c\u4e03\u9879\u5dee\u4ef7\u9010\u9879\u5217<\/h2>\n<p>\u8fd9\u4e00\u6bb5\u662f\u5ba2\u6237\u6700\u5e38\u95ee\u7684\u201c\u4e3a\u4ec0\u4e48\u6211\u5bb6\u8d35\u4e00\u5343\u201d\uff0c\u4e5f\u6700\u5bb9\u6613\u9010\u9879\u6838\u5bf9\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u9879\u76ee<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u4f4e\u4ef7\u505a\u6cd5<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u89c4\u8303\u505a\u6cd5<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u5dee\u4ef7\u53c2\u8003<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5185\u673a\u8fde\u63a5\u4ef6<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u9053\u76f4\u63a5\u786c\u63a5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e0d\u9508\u94a2\u6ce2\u7eb9\u8f6f\u63a5\uff0bPPR \u6d3b\u63a5\uff0c\u8fdb\u56de\u6c34\u5404\u4e00\u5957<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ea6 100 \u5143\/\u53f0<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u673a\u8fde\u63a5\u4ef6<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u786c\u63a5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e0d\u9508\u94a2\u8f6f\u63a5\uff0c\u8fdb\u56de\u6c34\u5404\u4e00\u5957<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ea6 160 \u5143\/\u53f0<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e8c\u901a\u9600<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u624b\u52a8\u9600\u6216\u4e0d\u914d<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7535\u5b50\u4e8c\u901a\u9600\uff08\u542b\u63a5\u7ebf\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ea6 100 \u5143\/\u5957<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u9600\u67c4<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u666e\u901a\u9600\u67c4<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u9632\u7ed3\u9732\u9600\u67c4<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ea6 30 \u5143\/\u4e2a<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e0d\u914d\uff0c\u9760\u81ea\u7136\u5761\u5ea6<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u914d\u63d0\u5347\u6cf5\uff0c\u540a\u9876\u4e0d\u53d7\u5761\u5ea6\u9650\u5236<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ea6 300 \u5143\/\u53f0<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">PE \u751f\u6001\u51c0\u5316\u6a21\u5757<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e0d\u914d<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u65e5\u7acb PE \u751f\u6001\u51c0\u5316\u6a21\u5757<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">400 \u5143\/\u4e2a\uff08\u542b\u4eba\u5de5\uff09<\/td><\/tr>\n<tr style=\"background:#fffdf5;\"><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>\u98ce\u673a\u76d8\u7ba1<\/strong><\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u534a\u5305\u5f0f\u7b80\u6613\u98ce\u76d8<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8d85\u9759\u97f3\u76f4\u6d41\u53d8\u9891\u5168\u5c01\u95ed\u98ce\u76d8<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>2,000 \u5143\u4ee5\u4e0a\/\u53f0<\/strong><\/td><\/tr>\n<\/tbody><\/table>\n\n<h3>\u5dee\u5f97\u6700\u72e0\u7684\u662f\u98ce\u673a\u76d8\u7ba1\uff0c\u4e0d\u662f\u4e3b\u673a<\/h3>\n<p>\u534a\u5305\u5f0f\u98ce\u76d8\u548c\u8d85\u9759\u97f3\u76f4\u6d41\u53d8\u9891\u5168\u5c01\u95ed\u98ce\u76d8\uff0c\u662f\u4e24\u79cd\u4e1c\u897f\u3002\u534a\u5305\u5f0f\u7684\u63a5\u6c34\u76d8\u4e0a\u65b9\u673a\u58f3\u5916\u9732\uff0c\u4fdd\u6e29\u548c\u51b7\u51dd\u5904\u7406\u80fd\u7701\u5c31\u7701\uff0c\u5355\u53f0\u4fbf\u5b9c\u4e24\u5343\u4ee5\u4e0a\uff1b\u5168\u5c01\u95ed\u7684\u4fdd\u6e29\u5b8c\u6574\u3001\u51b7\u51dd\u5904\u7406\u5230\u4f4d\u3001\u7535\u673a\u662f\u76f4\u6d41\u53d8\u9891\uff0c\u566a\u97f3\u548c\u80fd\u8017\u90fd\u4f4e\u4e00\u4e2a\u6863\u3002\u4e00\u5957\u4e94\u53f0\uff0c\u5149\u8fd9\u4e00\u9879\u5c31\u5dee\u4e00\u4e07\u3002<\/p>\n<p>\u5ba2\u6237\u5f88\u96be\u4ece\u62a5\u4ef7\u5355\u4e0a\u770b\u51fa\u6765\u2014\u2014\u4e24\u5bb6\u7684\u5355\u5b50\u4e0a\u90fd\u5199\u201c\u98ce\u673a\u76d8\u7ba1 5 \u53f0\u201d\uff0c\u578b\u53f7\u53ef\u80fd\u53ea\u5dee\u51e0\u4e2a\u5b57\u6bcd\u3002<strong>\u8fd9\u5c31\u662f\u4e3a\u4ec0\u4e48\u6bd4\u6c34\u673a\u62a5\u4ef7\uff0c\u5fc5\u987b\u6bd4\u578b\u53f7\uff0c\u4e0d\u80fd\u6bd4\u53f0\u6570\u3002<\/strong><\/p>\n\n<h3>\u8f6f\u63a5\u4e0d\u53ea\u662f\u51cf\u632f\uff0c\u662f\u9632\u7ba1\u8def\u5e94\u529b<\/h3>\n<p>\u4e3b\u673a\u548c\u5185\u673a\u7684\u8fde\u63a5\u5904\uff0c\u6c34\u6cf5\u542f\u505c\u4f1a\u6709\u6c34\u9524\uff0c\u7ba1\u9053\u70ed\u80c0\u51b7\u7f29\u4e5f\u4f1a\u6709\u4f4d\u79fb\u3002\u786c\u63a5\u7684\u7ba1\u8def\uff0c\u8fd9\u4e9b\u529b\u6700\u540e\u90fd\u4f20\u5230\u63a5\u5934\u548c\u76d8\u7ba1\u4e0a\uff1b\u8f6f\u63a5\u7528\u4e0d\u9508\u94a2\u6ce2\u7eb9\u7ba1\u5438\u6536\u6389\uff0c\u63a5\u5934\u4e0d\u627f\u529b\uff0c\u5bff\u547d\u957f\u5f97\u591a\u3002\u5dee\u4ef7\u4e00\u53f0\u4e00\u767e\u6765\u5757\uff0c\u5f88\u591a\u4eba\u5c31\u7701\u4e86\u8fd9\u4e00\u767e\u3002<\/p>\n\n<h3>\u9632\u7ed3\u9732\u9600\u67c4\uff1a\u6210\u90fd\u590f\u5929\u624d\u77e5\u9053\u5b83\u503c\u94b1<\/h3>\n<p>\u6210\u90fd\u6885\u96e8\u5b63\u6e7f\u5ea6 80% \u4ee5\u4e0a\uff0c\u6697\u88c5\u9600\u4f53\u8868\u9762\u6e29\u5ea6\u4f4e\u4e8e\u9732\u70b9\u5c31\u4f1a\u7ed3\u9732\uff0c\u6c34\u987a\u7740\u9600\u67c4\u6ef4\u5230\u540a\u9876\u4e0a\u3002\u9632\u7ed3\u9732\u9600\u67c4\u51e0\u5341\u5757\u94b1\u4e00\u4e2a\uff0c\u662f\u90a3\u79cd\u5e73\u65f6\u60f3\u4e0d\u8d77\u6765\u3001\u51fa\u95ee\u9898\u65f6\u62c6\u540a\u9876\u7684\u4e1c\u897f\u3002<\/p>\n\n<h2>\u7b2c\u56db\u672c\u8d26\uff1a\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u670d\u52a1\uff0c\u6700\u5bb9\u6613\u88ab\u201c\u514d\u8d39\u8bbe\u8ba1\u201d\u62b9\u6389<\/h2>\n<p>\u89c4\u8303\u62a5\u4ef7\u91cc\uff0c\u8bbe\u8ba1\u4e0e\u670d\u52a1\u662f\u6309\u98ce\u76d8\u5355\u72ec\u8ba1\u4ef7\u7684\uff1a<strong>2,000 \u5143\/\u98ce\u76d8<\/strong>\uff0c\u5305\u542b\u8bbe\u8ba1\u5b9a\u4f4d\u3001\u5b89\u88c5\u76d1\u7406\u3001\u7ba1\u9053\u8054\u4fdd\u3001\u7cfb\u7edf\u8c03\u8bd5\u3002\u8fd9\u4e00\u9879\u5305\u542b\u7684\u5177\u4f53\u5de5\u4f5c\uff1a<\/p>\n<p>\u2460 <strong>\u8d1f\u8377\u6838\u7b97<\/strong>\uff1a\u9010\u95f4\u7b97\u51b7\u70ed\u8d1f\u8377\uff0c\u4e0d\u662f\u6309\u9762\u79ef\u4e58\u4e00\u4e2a\u6570\uff1b<br>\n\u2461 <strong>\u6c34\u529b\u5e73\u8861\u8bbe\u8ba1<\/strong>\uff1a\u7b97\u6bcf\u4e2a\u56de\u8def\u7684\u6d41\u91cf\u3001\u963b\u529b\uff0c\u9009\u7ba1\u5f84\u3001\u5b9a\u6c34\u6cf5\u626c\u7a0b\uff1b<br>\n\u2462 <strong>\u7ba1\u8def\u89c4\u5212<\/strong>\uff1a\u4e3b\u7ba1\u8d70\u5411\u3001\u652f\u7ba1\u5206\u914d\u3001\u6881\u4e0a\u5f00\u5b54\u907f\u8ba9\u627f\u91cd\uff1b<br>\n\u2463 <strong>\u8fc7\u7a0b\u76d1\u7406<\/strong>\uff1a\u6253\u538b\u3001\u4fdd\u538b\u3001\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u7559\u6863\uff1b<br>\n\u2464 <strong>\u7cfb\u7edf\u8c03\u8bd5<\/strong>\uff1a\u6392\u6c14\u3001\u6d41\u91cf\u8c03\u6574\u3001\u8054\u52a8\u903b\u8f91\u3001\u5404\u623f\u95f4\u6e29\u5ea6\u5e73\u8861\uff1b<br>\n\u2465 <strong>\u8054\u4fdd\u4e0e\u552e\u540e<\/strong>\uff1a\u51fa\u95ee\u9898\u662f\u540c\u4e00\u5bb6\u8d1f\u8d23\uff0c\u4e0d\u662f\u8bbe\u5907\u5546\u63a8\u5b89\u88c5\u5546\u3002<\/p>\n<p>\u201c\u514d\u8d39\u8bbe\u8ba1\u201d\u8fd9\u53e5\u8bdd\u542c\u7740\u8212\u670d\uff0c\u4f46\u8bbe\u8ba1\u4e0d\u4f1a\u6d88\u5931\uff0c\u53ea\u4f1a\u53d8\u6210\u67d0\u4e2a\u4eba\u7684\u7ecf\u9a8c\u2014\u2014\u6216\u8005\u53d8\u6210\u6ca1\u4eba\u505a\u3002\u5c11\u4e86\u6c34\u529b\u8ba1\u7b97\u7684\u6c34\u7cfb\u7edf\uff0c\u6700\u5e38\u89c1\u7684\u540e\u679c\u662f\u8fdc\u7aef\u4e0d\u70ed\u3001\u8fd1\u7aef\u8fc7\u70ed\uff0c\u600e\u4e48\u8c03\u90fd\u8c03\u4e0d\u5e73\u3002<\/p>\n<p>\u4eba\u5de5\u8fd8\u6709\u4e2a\u786c\u5dee\u522b\uff1a\u6c1f\u673a\u5e08\u5085\u4e00\u5929\u80fd\u88c5\u4e24\u4e09\u53f0\u5185\u673a\uff0c\u6c34\u673a\u5e08\u5085\u4e00\u5929\u6700\u591a\u4e00\u53f0\u534a\u2014\u2014\u63a5\u7ba1\u3001\u6392\u6c14\u3001\u6253\u538b\u3001\u8c03\u5e73\u8861\uff0c\u6bcf\u4e00\u9879\u90fd\u8d39\u65f6\u95f4\u3002<strong>\u6c34\u673a\u7684\u4eba\u5de5\u6210\u672c\u5929\u751f\u6bd4\u6c1f\u673a\u9ad8\uff0c\u8fd9\u662f\u7269\u7406\u51b3\u5b9a\u7684\uff0c\u4e0d\u662f\u670d\u52a1\u5546\u60f3\u591a\u6536\u3002<\/strong><\/p>\n\n<h2>\u5730\u6696\u4fa7\u4e5f\u6709\u5dee\u4ef7\uff1a99 \u548c 155 \u5dee\u5728\u54ea<\/h2>\n<p>\u6c34\u673a\u4e24\u8054\u4f9b\u7684\u53e6\u4e00\u534a\u662f\u5730\u6696\u3002\u5730\u6696\u62a5\u4ef7\u770b\u8d77\u6765\u90fd\u662f\u201c\u591a\u5c11\u5143\u4e00\u5e73\u7c73\u201d\uff0c\u4f46\u7ec4\u6210\u5b8c\u5168\u4e0d\u540c\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u9879\u76ee<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u5e02\u573a\u901a\u914d\uff08\u57fa\u7840\u7248\uff09<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u8282\u80fd\u670d\u52a1\u7cfb\u7edf\uff08\u6807\u914d\u7248\uff09<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u9053\u7cfb\u7edf<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">25-16 \u7ec4\u5408\uff0c30 \u5143\/\u33a1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">25-16 \u7ec4\u5408\uff0c30 \u5143\/\u33a1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4fdd\u6e29\u5c42<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u666e\u901a\u6324\u5851\u677f\uff0c15 \u5143\/\u33a1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u666e\u901a\u6324\u5851\u677f\uff0c15 \u5143\/\u33a1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u56de\u586b\u5c42<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">30 \u5143\/\u33a1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">30 \u5143\/\u33a1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5b89\u88c5\u4eba\u5de5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">24 \u5143\/\u33a1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">24 \u5143\/\u33a1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5206\u5ba4\u63a7\u6e29\u7ebf\u63a7\u5668<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5df2\u542b<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5df2\u542b\uff08\u6c34\u673a\u5730\u6696\u672c\u8eab\u914d\u7ebf\u63a7\u5668\u5206\u63a7\uff09<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7b2c\u4e09\u65b9\u8bbe\u8ba1\u4e0e\u76d1\u7406<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e0d\u542b<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">36 \u5143\/\u33a1<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u9053\u6295\u4fdd<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e0d\u542b<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u542b\uff08\u7ba1\u9053\u7531\u4fdd\u9669\u516c\u53f8\u627f\u4fdd\uff09<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u5f84\u4e0e\u56de\u8def<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6309\u6700\u4f4e\u914d\u7f6e\uff0c25-16<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6309\u8d1f\u8377\u914d\uff0cDe32\uff0bDe20 \u7b49<\/td><\/tr>\n<tr style=\"background:#fffdf5;\"><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>\u5408\u8ba1<\/strong><\/td><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>99 \u5143\/\u33a1<\/strong><\/td><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>155 \u5143\/\u33a1 \u8d77<\/strong>\uff08\u7ba1\u5f84\u5347\u7ea7\uff0b\u6295\u4fdd\u540e 160 \u4ee5\u4e0a\uff09<\/td><\/tr>\n<\/tbody><\/table>\n<p><strong>\u5148\u8bf4\u6e05\u4e00\u4ef6\u4e8b\uff1a\u5206\u5ba4\u63a7\u6e29\u4e0d\u662f\u5dee\u4ef7\u9879\u3002<\/strong>\u6c34\u673a\u7684\u91c7\u6696\u672b\u7aef\u672c\u6765\u5c31\u914d\u7ebf\u63a7\u5668\uff0c\u6bcf\u4e2a\u623f\u95f4\u5355\u72ec\u63a7\u6e29\u662f\u6807\u51c6\u914d\u7f6e\uff0c\u8fd9\u4e00\u70b9\u548c\u9505\u7089\u5730\u6696\u4e0d\u540c\uff0c\u4e0d\u9700\u8981\u989d\u5916\u52a0\u94b1\u3002<\/p>\n<p>\u771f\u6b63\u7684\u5dee\u4ef7\u5728\u8fd9\u4e09\u5904\uff1a<strong>\u7b2c\u4e09\u65b9\u8bbe\u8ba1\u4e0e\u76d1\u7406<\/strong>\uff08\u7ba1\u8def\u600e\u4e48\u8d70\u3001\u963b\u529b\u600e\u4e48\u5e73\u3001\u8c01\u6765\u9a8c\u6536\uff09\u3001<strong>\u7ba1\u9053\u6295\u4fdd<\/strong>\uff08\u7ba1\u9053\u7531\u4fdd\u9669\u516c\u53f8\u627f\u4fdd\uff0c\u51fa\u95ee\u9898\u6709\u8d54\u4ed8\u4e3b\u4f53\uff09\u3001<strong>\u7ba1\u5f84\u4e0e\u56de\u8def\u914d\u7f6e<\/strong>\uff08\u6309\u8d1f\u8377\u914d De32\uff0bDe20\uff0c\u8fd8\u662f\u5168\u5c4b\u7528\u6700\u4f4e\u914d\u7684 25-16\uff09\u3002\u8fd9\u51e0\u9879\u52a0\u8d77\u6765\uff0c\u4e24\u7248\u7684\u4ef7\u5dee\u901a\u5e38\u5728 60 \u5143\/\u33a1 \u4ee5\u4e0a\uff0c100\u33a1 \u91c7\u6696\u9762\u79ef\u5c31\u662f 6,000 \u5143\u4ee5\u4e0a\u3002<\/p>\n<p>\u5f80\u4e0a\u8fd8\u6709\u5347\u7ea7\u9009\u9879\uff1a\u4f1f\u661f\u767d\u6676\u677f\u52a0 15 \u5143\/\u33a1\u3001\u7eff\u7fbd\u767d\u6676\u677f\u52a0 25 \u5143\/\u33a1\u3001\u963b\u6c27\u7ba1\u52a0 10 \u5143\/\u33a1\u3001\u7ba1\u5f84\u5347\u7ea7 De32\uff0bDe20 \u52a0 15 \u5143\/\u33a1\u3002\u76d8\u7ba1\u95f4\u8ddd 150mm \u548c 125mm \u7684\u5dee\u522b\uff0c\u4e5f\u5728\u8fd9\u91cc\u4f53\u73b0\u2014\u2014\u95f4\u8ddd\u8d8a\u5bc6\uff0c\u5355\u4f4d\u9762\u79ef\u7ba1\u6750\u8d8a\u591a\uff0c\u70ed\u91cf\u66f4\u5747\u5300\u3002<\/p>\n\n<h2>\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\uff0c\u4e00\u7b14\u5b8c\u6574\u8d26<\/h2>\n<p>\u628a\u56db\u672c\u8d26\u5408\u8d77\u6765\u770b\uff0c\u4e00\u5957 200 \u4e3b\u673a\u4ee5\u5185\u30015 \u53f0\u5185\u673a\u3001100\u33a1 \u91c7\u6696\u9762\u79ef\u7684\u6c34\u673a\uff0c\u9664\u8bbe\u5907\u4ee5\u5916\u7684\u89c4\u8303\u6210\u672c\u6784\u6210\u5927\u81f4\u662f\u8fd9\u6837\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u9879\u76ee<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7b97\u6cd5<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u91d1\u989d<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">200 \u4e3b\u673a\u4ee5\u5185<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">3,600 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7cfb\u7edf\u9009\u6750\uff08\u7ba1\u9053\u4fdd\u6e29\u9600\u95e8\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5 \u53f0 \u00d7 1,700<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">8,500 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u670d\u52a1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5 \u53f0 \u00d7 2,000<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">10,000 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5730\u6696\uff08\u8282\u80fd\u670d\u52a1\u7cfb\u7edf\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">100\u33a1 \u00d7 155<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">15,500 \u5143<\/td><\/tr>\n<tr style=\"background:#fffdf5;\"><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>\u4e0d\u542b\u8bbe\u5907\u5408\u8ba1<\/strong><\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2014<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>37,600 \u5143<\/strong><\/td><\/tr>\n<\/tbody><\/table>\n<p><strong>\u5f88\u591a\u5ba2\u6237\u4ee5\u4e3a\u201c\u62a5\u4ef7\u51cf\u53bb\u8bbe\u5907\u4ef7\uff0c\u5269\u4e0b\u7684\u5c31\u662f\u5b89\u88c5\u8d39\u201d\uff0c\u4e00\u770b\u5413\u4e00\u8df3\u2014\u2014\u786e\u5b9e\u63a5\u8fd1\u56db\u4e07\u3002<\/strong>\u8fd9\u7b14\u94b1\u4e0d\u662f\u5229\u6da6\uff0c\u662f\u7ba1\u9053\u3001\u4fdd\u6e29\u3001\u9600\u95e8\u3001\u8bbe\u8ba1\u3001\u76d1\u7406\u3001\u8c03\u8bd5\u548c\u5730\u6696\u672c\u8eab\u7684\u6210\u672c\u3002<\/p>\n<p>\u53cd\u8fc7\u6765\uff0c\u5982\u679c\u8fd9\u56db\u672c\u8d26\u90fd\u6309\u7b80\u5316\u505a\u6cd5\u505a\uff0c\u80fd\u7701\u6389\u591a\u5c11\uff1f<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7701\u6cd5<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7b97\u6cd5<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7701\u4e0b<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u98ce\u673a\u76d8\u7ba1\u6362\u534a\u5305\u5f0f<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5 \u53f0 \u00d7 2,000<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">10,000 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u6750\u964d\u6863\uff08PE-Xa \u6216\u8584\u58c1\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5 \u53f0 \u00d7 400<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">2,000 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5730\u6696\u964d\u5230\u901a\u914d\u7248<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">100\u33a1 \u00d7 56<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5,600 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8f6f\u63a5\u6539\u786c\u63a5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5\u00d7100\uff0b160<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">660 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e8c\u901a\u9600\u3001\u9600\u67c4\u3001\u63d0\u5347\u6cf5\u3001PE \u6a21\u5757\u4e0d\u914d<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5\u00d7(100\uff0b30\uff0b300\uff0b400)<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">4,150 \u5143<\/td><\/tr>\n<tr style=\"background:#fffdf5;\"><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>\u5408\u8ba1\u53ef\u7701<\/strong><\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2014<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\"><strong>22,410 \u5143<\/strong><\/td><\/tr>\n<\/tbody><\/table>\n<p>\u4e24\u4e07\u4e8c\u7684\u5dee\u4ef7\uff0c\u5c31\u662f\u8fd9\u4e48\u6765\u7684\u3002<strong>\u6ca1\u6709\u4e00\u5bb6\u4f1a\u544a\u8bc9\u4f60\u4ed6\u7701\u4e86\u54ea\u51e0\u9879\uff0c\u62a5\u4ef7\u5355\u4e0a\u901a\u5e38\u53ea\u5199\u201c\u6c34\u673a\u4e00\u5957\u201d\u548c\u201c\u5730\u6696\u82e5\u5e72\u5e73\u7c73\u201d\u3002<\/strong><\/p>\n\n<h2>\u7701\u4e0b\u8fd9\u4e24\u4e07\u4e8c\uff0c\u4ee3\u4ef7\u662f\u4ec0\u4e48<\/h2>\n<p>\u8fd9\u4e0d\u662f\u5413\u4eba\u7684\u8bdd\uff0c\u662f\u8fd4\u5de5\u73b0\u573a\u6700\u5e38\u89c1\u7684\u60c5\u51b5\uff1a<\/p>\n<p>\u2460 <strong>\u534a\u5305\u5f0f\u98ce\u76d8<\/strong>\u2014\u2014\u63a5\u6c34\u76d8\u4e0a\u65b9\u65e0\u4fdd\u6e29\uff0c\u590f\u5929\u51b7\u51dd\u6c34\u6e17\u5230\u540a\u9876\uff0c\u5148\u8d77\u9709\u70b9\uff0c\u518d\u6ef4\u6c34\uff1b\u7535\u673a\u4e0d\u662f\u76f4\u6d41\u53d8\u9891\uff0c\u566a\u97f3\u5927\u3001\u8017\u7535\u9ad8\uff1b<br>\n\u2461 <strong>\u8584\u58c1\u7ba1\u6216\u964d\u6863\u7ba1\u6750<\/strong>\u2014\u2014\u4e24\u4e09\u5e74\u540e\u627f\u538b\u4f59\u91cf\u4e0d\u8db3\uff0c\u63a5\u5934\u6e17\u6c34\u7684\u6982\u7387\u4e0a\u5347\uff1b<br>\n\u2462 <strong>\u4fdd\u6e29\u51cf\u8584<\/strong>\u2014\u2014\u7ba1\u9053\u51dd\u6c34\uff0c\u540a\u9876\u91cc\u957f\u671f\u6f6e\u6e7f\uff0c\u6728\u9f99\u9aa8\u548c\u77f3\u818f\u677f\u90fd\u53d7\u5f71\u54cd\uff1b<br>\n\u2463 <strong>\u6ca1\u6709\u7535\u5b50\u4e8c\u901a\u9600<\/strong>\u2014\u2014\u623f\u95f4\u4e0d\u7528\u65f6\u6c34\u7167\u8d70\uff0c\u80fd\u8017\u4e0a\u53bb\uff0c\u8fd8\u8c03\u4e0d\u4e86\u5355\u95f4\u6e29\u5ea6\uff1b<br>\n\u2464 <strong>\u6ca1\u6709\u63d0\u5347\u6cf5<\/strong>\u2014\u2014\u51b7\u51dd\u6c34\u53ea\u80fd\u9760\u5761\u5ea6\u8d70\uff0c\u540a\u9876\u88ab\u8feb\u538b\u4f4e\uff1b<br>\n\u2465 <strong>\u6ca1\u6709\u8bbe\u8ba1\u548c\u6c34\u529b\u8ba1\u7b97<\/strong>\u2014\u2014\u8fdc\u7aef\u4e0d\u70ed\u3001\u8fd1\u7aef\u8fc7\u70ed\uff0c\u8c03\u4e0d\u5e73\u53ea\u80fd\u62c6\u6539\uff1b<br>\n\u2466 <strong>\u5730\u6696\u964d\u5230\u901a\u914d\u7248<\/strong>\u2014\u2014\u6ca1\u6709\u5206\u5ba4\u63a7\u6e29\uff0c\u5168\u5c4b\u4e00\u8d77\u5f00\u4e00\u8d77\u5173\uff1b\u6ca1\u6709\u7b2c\u4e09\u65b9\u76d1\u7406\uff0c\u6253\u538b\u548c\u9690\u853d\u5de5\u7a0b\u5168\u51ed\u5e08\u5085\u81ea\u89c9\u3002<\/p>\n<p>\u8fd9\u4e9b\u95ee\u9898\u7684\u5171\u540c\u70b9\u662f\uff1a<strong>\u88c5\u7684\u65f6\u5019\u770b\u4e0d\u51fa\u6765\uff0c\u4f4f\u8fdb\u53bb\u534a\u5e74\u5230\u4e24\u5e74\u624d\u9646\u7eed\u51fa\u73b0\uff0c\u800c\u90a3\u65f6\u5019\u540a\u9876\u5df2\u7ecf\u5c01\u4e86\u3002<\/strong><\/p>\n\n<h2>\u552e\u540e\u80fd\u529b\uff0c\u4e5f\u662f\u62a5\u4ef7\u7684\u4e00\u90e8\u5206<\/h2>\n<p>\u8fd8\u6709\u4e00\u9879\u6ca1\u6cd5\u5199\u8fdb\u62a5\u4ef7\u5355\uff0c\u4f46\u786e\u5b9e\u503c\u94b1\uff1a\u51fa\u95ee\u9898\u7684\u65f6\u5019\uff0c\u6709\u6ca1\u6709\u4eba\u6765\u3002<\/p>\n<p>\u6c34\u7cfb\u7edf\u7684\u552e\u540e\u4e0d\u662f\u201c\u4fee\u4e2a\u96f6\u4ef6\u201d\u90a3\u4e48\u7b80\u5355\u2014\u2014\u8981\u627e\u6f0f\u70b9\u3001\u8981\u6392\u6c34\u3001\u8981\u91cd\u65b0\u6253\u538b\u3001\u8981\u62c6\u540a\u9876\u3002\u505a\u6c34\u7cfb\u7edf\u7684\u670d\u52a1\u5546\uff0c\u80cc\u540e\u5f97\u6709\u7a33\u5b9a\u7684\u5b89\u88c5\u73ed\u7ec4\u548c\u4e13\u804c\u552e\u540e\uff1b\u53ea\u505a\u8bbe\u5907\u5012\u5356\u3001\u9760\u4e34\u65f6\u627e\u961f\u4f0d\u65bd\u5de5\u7684\uff0c\u51fa\u95ee\u9898\u65f6\u6700\u5e38\u89c1\u7684\u8868\u73b0\u4e0d\u662f\u4e0d\u5904\u7406\uff0c\u800c\u662f\u62d6\u7740\u2014\u2014\u56e0\u4e3a\u4ed6\u4eec\u6ca1\u6709\u80fd\u6d3e\u7684\u961f\u4f0d\u3002<\/p>\n<p>\u9009\u6c34\u673a\u7684\u65f6\u5019\uff0c\u5efa\u8bae\u591a\u95ee\u4e00\u53e5\uff1a<strong>\u4f60\u4eec\u81ea\u5df1\u7684\u5b89\u88c5\u5e08\u5085\u662f\u51e0\u4e2a\u4eba\uff1f\u552e\u540e\u591a\u4e45\u80fd\u5230\uff1f\u4e0a\u6b21\u6c34\u673a\u8fd4\u5de5\u662f\u4ec0\u4e48\u65f6\u5019\uff1f<\/strong>\u7b54\u5f97\u75db\u5feb\u7684\uff0c\u901a\u5e38\u662f\u771f\u7684\u6709\u961f\u4f0d\u3002<\/p>\n\n<h2>\u62ff\u5230\u62a5\u4ef7\u5355\uff0c\u6309\u8fd9\u4efd\u6e05\u5355\u9010\u9879\u6838\u5bf9<\/h2>\n<p>\u4e0d\u7528\u61c2\u6280\u672f\uff0c\u62ff\u7740\u4e24\u4efd\u62a5\u4ef7\u5355\u5bf9\u7740\u67e5\u8fd9\u4e5d\u9879\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tbody><tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">#<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u6838\u5bf9\u9879<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u8bf4\u660e\u6e05\u695a\u7684\u6807\u5fd7<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">1<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e3b\u673a\u578b\u53f7\u4e0e\u5339\u6570<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5199\u660e\u5b8c\u6574\u578b\u53f7\uff0c\u4e0d\u662f\u201c3 \u5339\u4e3b\u673a\u201d<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">2<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u98ce\u673a\u76d8\u7ba1\u578b\u53f7<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5199\u660e\u534a\u5305\u8fd8\u662f\u5168\u5c01\u95ed\u3001\u4ea4\u6d41\u8fd8\u662f\u76f4\u6d41\u53d8\u9891<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">3<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u6750\u54c1\u724c\u4e0e\u58c1\u539a<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5199\u660e\u7ba1\u5f84\u7ec4\u5408\u4e0e\u7ba1\u6750\u7cfb\u5217<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">4<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4fdd\u6e29\u89c4\u683c<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5199\u660e\u539a\u5ea6\u4e0e\u7b49\u7ea7\uff08\u5982 20mm B1 \u7ea7\uff09<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">5<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u9600\u95e8\u6e05\u5355<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e8c\u901a\u9600\u3001\u538b\u5dee\u65c1\u901a\u3001\u6392\u6c14\u3001\u8865\u6c34\u3001\u5b89\u5168\u9600\u662f\u5426\u5217\u51fa<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">6<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8fde\u63a5\u65b9\u5f0f<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8f6f\u63a5\u8fd8\u662f\u786c\u63a5\uff0c\u5199\u4e0d\u5199<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">7<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u63d0\u5347\u6cf5\u4e0e\u51c0\u5316\u6a21\u5757<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u542b\u4e0d\u542b\uff0c\u542b\u5c31\u5199\u51fa\u578b\u53f7<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">8<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u8bbe\u8ba1\u8d39\u662f\u5426\u5355\u5217<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6709\u8bbe\u8ba1\u3001\u76d1\u7406\u3001\u8c03\u8bd5\u7684\u72ec\u7acb\u6761\u76ee<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">9<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5730\u6696\u6784\u6210<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u7ba1\u9053\u3001\u4fdd\u6e29\u3001\u56de\u586b\u3001\u4eba\u5de5\u3001\u5206\u63a7\u5206\u5217<\/td><\/tr>\n<\/tbody><\/table>\n<p>\u8fd9\u4e5d\u9879\u91cc\uff0c\u4efb\u4f55\u4e00\u9879\u5199\u201c\u6309\u6807\u51c6\u914d\u7f6e\u201d\u6216\u8005\u5e72\u8106\u4e0d\u5199\u7684\uff0c\u90fd\u8981\u8ffd\u95ee\u5177\u4f53\u578b\u53f7\u3002<strong>\u6c34\u673a\u62a5\u4ef7\u7684\u6b63\u786e\u6bd4\u6cd5\uff0c\u662f\u5148\u6bd4\u914d\u7f6e\u6e05\u5355\uff0c\u518d\u6bd4\u603b\u4ef7<\/strong>\u2014\u2014\u53cd\u8fc7\u6765\u6bd4\uff0c\u4e00\u5b9a\u88ab\u4f4e\u4ef7\u5e26\u8d70\u3002<\/p>\n\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n\n<h3>\u4e3a\u4ec0\u4e48\u540c\u4e00\u53f0\u4e3b\u673a\uff0c\u4e24\u5bb6\u62a5\u4ef7\u80fd\u5dee\u4e24\u4e07\uff1f<\/h3>\n<p>\u4e3b\u673a\u4ef7\u683c\u662f\u900f\u660e\u7684\uff0c\u5dee\u4ef7\u90fd\u5728\u4e3b\u673a\u4ee5\u5916\u7684\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u4e00\u62d6\u4e94\u52a0 100\u33a1 \u5730\u6696\uff0c\u5982\u679c\u8fd9\u56db\u9879\u5168\u6309\u7b80\u5316\u505a\u6cd5\uff0c\u5408\u8ba1\u80fd\u7701\u4e24\u4e07\u4e8c\u5de6\u53f3\u3002<\/p>\n\n<h3>\u62a5\u4ef7\u5355\u4e0a\u53ea\u5199\u201c\u6c34\u673a\u4e00\u5957\u201d\uff0c\u6b63\u5e38\u5417\uff1f<\/h3>\n<p>\u4e0d\u6b63\u5e38\u3002\u6c34\u673a\u662f\u975e\u6807\u7cfb\u7edf\uff0c\u5fc5\u987b\u9010\u9879\u5217\u660e\uff1a\u7ba1\u6750\u54c1\u724c\u4e0e\u7ba1\u5f84\u3001\u4fdd\u6e29\u539a\u5ea6\u3001\u98ce\u76d8\u578b\u53f7\u3001\u9600\u95e8\u6e05\u5355\u3001\u662f\u5426\u542b\u8bbe\u8ba1\u4e0e\u8c03\u8bd5\u3002\u5199\u201c\u4e00\u5957\u201d\u7684\uff0c\u7b49\u4e8e\u628a\u89e3\u91ca\u6743\u7559\u7ed9\u4e86\u5bf9\u65b9\u3002<\/p>\n\n<h3>\u201c\u514d\u8d39\u8bbe\u8ba1\u201d\u548c\u6536\u8d39\u8bbe\u8ba1\u6709\u4ec0\u4e48\u5dee\u522b\uff1f<\/h3>\n<p>\u5dee\u522b\u5728\u6709\u6ca1\u6709\u771f\u7684\u505a\u8bbe\u8ba1\u3002\u6536\u8d39\u8bbe\u8ba1\u5305\u542b\u9010\u95f4\u8d1f\u8377\u6838\u7b97\u3001\u6c34\u529b\u5e73\u8861\u8ba1\u7b97\u3001\u7ba1\u8def\u89c4\u5212\u3001\u65bd\u5de5\u76d1\u7406\u548c\u7cfb\u7edf\u8c03\u8bd5\uff1b\u514d\u8d39\u8bbe\u8ba1\u5f80\u5f80\u53ea\u662f\u753b\u4e2a\u4f4d\u7f6e\u56fe\uff0c\u6c34\u529b\u8ba1\u7b97\u9760\u7ecf\u9a8c\u4f30\u3002\u6c34\u7cfb\u7edf\u7684\u6548\u679c\u597d\u4e0d\u597d\uff0c\u516b\u6210\u53d6\u51b3\u4e8e\u8fd9\u4e00\u6b65\u3002<\/p>\n\n<h3>\u98ce\u673a\u76d8\u7ba1\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1f<\/h3>\n<p>\u534a\u5305\u5f0f\u548c\u8d85\u9759\u97f3\u76f4\u6d41\u53d8\u9891\u5168\u5c01\u95ed\u662f\u4e24\u79cd\u4ea7\u54c1\uff1a\u4fdd\u6e29\u5b8c\u6574\u5ea6\u3001\u51b7\u51dd\u6c34\u76d8\u5904\u7406\u3001\u7535\u673a\u7c7b\u578b\u90fd\u4e0d\u540c\uff0c\u5355\u53f0\u5dee\u4ef7 2,000 \u5143\u4ee5\u4e0a\u3002\u4e24\u5bb6\u62a5\u4ef7\u5355\u4e0a\u90fd\u5199\u201c\u98ce\u673a\u76d8\u7ba1 5 \u53f0\u201d\uff0c\u578b\u53f7\u53ea\u5dee\u51e0\u4e2a\u5b57\u6bcd\uff0c\u5fc5\u987b\u9010\u4e2a\u6838\u5bf9\u3002<\/p>\n\n<h3>\u5730\u6696 99 \u5143\u548c 155 \u5143\u4e00\u5e73\u7c73\uff0c\u5dee\u7684\u662f\u4ec0\u4e48\uff1f<\/h3>\n<p>\u5206\u5ba4\u63a7\u6e29\u4e0d\u662f\u5dee\u4ef7\u9879\u2014\u2014\u6c34\u673a\u5730\u6696\u672c\u8eab\u914d\u7ebf\u63a7\u5668\uff0c\u6bcf\u4e2a\u623f\u95f4\u5355\u72ec\u63a7\u6e29\u662f\u6807\u51c6\u914d\u7f6e\u3002\u771f\u6b63\u7684\u5dee\u4ef7\u5728\u4e09\u5904\uff1a\u7b2c\u4e09\u65b9\u8bbe\u8ba1\u4e0e\u76d1\u7406\u3001\u7ba1\u9053\u6295\u4fdd\u3001\u6309\u8d1f\u8377\u914d\u7ba1\u5f84\u4e0e\u56de\u8def\uff0c\u4e24\u7248\u901a\u5e38\u5dee 60 \u5143\/\u33a1 \u4ee5\u4e0a\u3002<\/p>\n\n<h3>\u6c34\u673a\u7684\u5b89\u88c5\u4eba\u5de5\u4e3a\u4ec0\u4e48\u6bd4\u6c1f\u673a\u8d35\uff1f<\/h3>\n<p>\u5de5\u5e8f\u4e0d\u540c\u3002\u6c1f\u673a\u63a5\u7ba1\u6807\u51c6\u5316\uff0c\u5e08\u5085\u4e00\u5929\u80fd\u88c5\u4e24\u4e09\u53f0\u5185\u673a\uff1b\u6c34\u673a\u8981\u63a5\u7ba1\u3001\u6392\u6c14\u3001\u6253\u538b\u3001\u8c03\u6c34\u529b\u5e73\u8861\uff0c\u4e00\u5929\u6700\u591a\u4e00\u53f0\u534a\u3002\u4eba\u5de5\u6210\u672c\u9ad8\u662f\u5de5\u5e8f\u51b3\u5b9a\u7684\u3002<\/p>\n\n<h3>\u7701\u4e0b\u6765\u7684\u94b1\uff0c\u540e\u9762\u4f1a\u4ee5\u4ec0\u4e48\u5f62\u5f0f\u8fd8\u56de\u53bb\uff1f<\/h3>\n<p>\u6700\u5e38\u89c1\u4e09\u79cd\uff1a\u7ba1\u9053\u51dd\u6c34\u6ef4\u540a\u9876\uff08\u4fdd\u6e29\u4e0d\u591f\uff09\u3001\u98ce\u76d8\u566a\u97f3\u548c\u51b7\u51dd\uff08\u534a\u5305\u5f0f\uff09\u3001\u7cfb\u7edf\u8c03\u4e0d\u5e73\uff08\u6ca1\u6709\u6c34\u529b\u8bbe\u8ba1\uff09\u3002\u8fd9\u4e09\u79cd\u90fd\u8981\u62c6\u540a\u9876\u624d\u80fd\u4fee\uff0c\u4ee3\u4ef7\u8fdc\u9ad8\u4e8e\u5f53\u521d\u7701\u4e0b\u7684\u94b1\u3002<\/p>\n\n<h3>\u600e\u4e48\u5224\u65ad\u4e00\u5bb6\u80fd\u4e0d\u80fd\u628a\u6c34\u673a\u505a\u597d\uff1f<\/h3>\n<p>\u95ee\u4e09\u4e2a\u95ee\u9898\uff1a\u81ea\u5df1\u7684\u5b89\u88c5\u5e08\u5085\u6709\u51e0\u4e2a\u4eba\u3001\u552e\u540e\u591a\u4e45\u80fd\u5230\u3001\u4e0a\u4e00\u5957\u6c34\u673a\u662f\u4ec0\u4e48\u65f6\u5019\u505a\u7684\u3002\u518d\u8981\u4e00\u4efd\u5e26\u7ba1\u5f84\u548c\u4fdd\u6e29\u89c4\u683c\u7684\u914d\u7f6e\u6e05\u5355\u2014\u2014\u505a\u5f97\u51fa\u6765\u7684\u4eba\uff0c\u901a\u5e38\u4e5f\u505a\u5f97\u51fa\u6765\u6d3b\u3002<\/p>\n\n<p style=\"font-size:14px;color:#6b7280;\">\u8bf4\u660e\uff1a\u4ee5\u4e0a\u5355\u4ef7\u4e3a\u672c\u516c\u53f8\u5e38\u89c4\u914d\u7f6e\u7684\u8ba1\u8d39\u6807\u51c6\uff0c\u7528\u4e8e\u5e2e\u52a9\u5ba2\u6237\u7406\u89e3\u62a5\u4ef7\u6784\u6210\uff0c\u4e0d\u7b49\u4e8e\u4efb\u4f55\u4e00\u5bb6\u7684\u62a5\u4ef7\u5355\uff1b\u5b9e\u9645\u4ef7\u683c\u968f\u54c1\u724c\u3001\u578b\u53f7\u3001\u9762\u79ef\u4e0e\u73b0\u573a\u6761\u4ef6\u6d6e\u52a8\uff0c\u4ee5\u6b63\u5f0f\u914d\u7f6e\u6e05\u5355\u548c\u62a5\u4ef7\u4e3a\u51c6\u3002<\/p>\n\n<h2>\u63a5\u7740\u5f80\u4e0b\u770b<\/h2>\n<p>\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=12825\">\u6210\u90fd\u6c34\u673a vs \u6c1f\u673a\u600e\u4e48\u9009<\/a>\u2014\u2014\u5929\u6c34\u5730\u6c34\u3001\u5929\u6c1f\u5730\u6c34\u3001\u591a\u8054\u673a\u4e00\u6b21\u5206\u6e05<br>\n\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15331\">\u6210\u90fd\u5929\u6c34\u5730\u6c34\u65b9\u6848\uff5c\u6c34\u5885\u9002\u6c34\u673a\u4e8c\u8054\u4f9b\u600e\u4e48\u9009<\/a>\u2014\u2014\u6c34\u7cfb\u7edf\u65b9\u6848\u7684\u5b8c\u6574\u62c6\u89e3<br>\n\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=13151\">\u65e5\u7acb\u6c34\u5885\u9002\u6548\u679c\u4e0e\u80fd\u8017\u5b9e\u6d4b<\/a>\u2014\u2014\u771f\u5b9e\u5bb6\u5ead\u7684\u8fd0\u884c\u6570\u636e<br>\n\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=5703\">\u65e5\u7acb PE \u751f\u6001\u51c0\u5316\u6a21\u5757\u5b8c\u6574\u4ecb\u7ecd<\/a>\u2014\u2014\u51c0\u5316\u6a21\u5757\u7684\u4f5c\u7528\u4e0e\u914d\u7f6e<br>\n\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=14764\">\u6c34\u5885\u9002\u4ef7\u683c<\/a>\u2014\u2014\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u7684\u4ef7\u683c\u6784\u6210<br>\n\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15567\">\u6210\u90fd\u5bb6\u5ead\u6696\u901a\u9009\u578b\u81ea\u6d4b<\/a>\u2014\u20143 \u4e2a\u63d0\u95ee\uff0b\u4f53\u611f 6 \u6761<\/p>\n<p>\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15999\">\u6c34\u673a\u914d\u9664\u6e7f\u65b0\u98ce\u7684\u94b1\u8981\u4e0d\u8981\u82b1<\/a>\u2014\u2014\u4e0d\u914d\u5c31\u5f97\u5728\u6e7f\u5ea6\u548c\u51fa\u98ce\u8212\u9002\u4e4b\u95f4\u4e8c\u9009\u4e00<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5148\u7ed9\u7ed3\u8bba\uff1a\u6c34\u673a\u62a5\u4ef7\u5dee\u7684\u662f\u201c\u56db\u672c\u8d26\u201d\uff0c\u4e0d\u662f [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-15911","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6c34\u673a\u4e24\u8054\u4f9b\u62a5\u4ef7\u5dee\u5f02\u6765\u81ea\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u6309\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\u9010\u9879\u5217\u51fa\u89c4\u8303\u6210\u672c\u6784\u6210\uff0c\u5e76\u8bf4\u660e\u7b80\u5316\u914d\u7f6e\u80fd\u7701\u6389\u4ec0\u4e48\u3001\u7701\u4e86\u540e\u671f\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\u3002\u4ee5\u73b0\u573a\u52d8\u6d4b\u6b63\u5f0f\u62a5\u4ef7\u4e3a\u51c6\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=15911\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6c34\u673a\u4e24\u8054\u4f9b\u62a5\u4ef7\u5dee\u5f02\u6765\u81ea\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u6309\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\u9010\u9879\u5217\u51fa\u89c4\u8303\u6210\u672c\u6784\u6210\uff0c\u5e76\u8bf4\u660e\u7b80\u5316\u914d\u7f6e\u80fd\u7701\u6389\u4ec0\u4e48\u3001\u7701\u4e86\u540e\u671f\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\u3002\u4ee5\u73b0\u573a\u52d8\u6d4b\u6b63\u5f0f\u62a5\u4ef7\u4e3a\u51c6\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=15911\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-21T10:50:36+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15911\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15911\",\"name\":\"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-10-21T07:35:04+00:00\",\"dateModified\":\"2026-10-21T10:50:36+00:00\",\"description\":\"\u6c34\u673a\u4e24\u8054\u4f9b\u62a5\u4ef7\u5dee\u5f02\u6765\u81ea\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u6309\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\u9010\u9879\u5217\u51fa\u89c4\u8303\u6210\u672c\u6784\u6210\uff0c\u5e76\u8bf4\u660e\u7b80\u5316\u914d\u7f6e\u80fd\u7701\u6389\u4ec0\u4e48\u3001\u7701\u4e86\u540e\u671f\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\u3002\u4ee5\u73b0\u573a\u52d8\u6d4b\u6b63\u5f0f\u62a5\u4ef7\u4e3a\u51c6\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15911#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15911\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15911#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b - \u9f99\u8109\u6696\u901a","description":"\u6c34\u673a\u4e24\u8054\u4f9b\u62a5\u4ef7\u5dee\u5f02\u6765\u81ea\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u6309\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\u9010\u9879\u5217\u51fa\u89c4\u8303\u6210\u672c\u6784\u6210\uff0c\u5e76\u8bf4\u660e\u7b80\u5316\u914d\u7f6e\u80fd\u7701\u6389\u4ec0\u4e48\u3001\u7701\u4e86\u540e\u671f\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\u3002\u4ee5\u73b0\u573a\u52d8\u6d4b\u6b63\u5f0f\u62a5\u4ef7\u4e3a\u51c6\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=15911","og_locale":"zh_CN","og_type":"article","og_title":"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b - \u9f99\u8109\u6696\u901a","og_description":"\u6c34\u673a\u4e24\u8054\u4f9b\u62a5\u4ef7\u5dee\u5f02\u6765\u81ea\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u6309\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\u9010\u9879\u5217\u51fa\u89c4\u8303\u6210\u672c\u6784\u6210\uff0c\u5e76\u8bf4\u660e\u7b80\u5316\u914d\u7f6e\u80fd\u7701\u6389\u4ec0\u4e48\u3001\u7701\u4e86\u540e\u671f\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\u3002\u4ee5\u73b0\u573a\u52d8\u6d4b\u6b63\u5f0f\u62a5\u4ef7\u4e3a\u51c6\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=15911","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-21T10:50:36+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=15911","url":"https:\/\/longmai-nt.com\/?page_id=15911","name":"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-10-21T07:35:04+00:00","dateModified":"2026-10-21T10:50:36+00:00","description":"\u6c34\u673a\u4e24\u8054\u4f9b\u62a5\u4ef7\u5dee\u5f02\u6765\u81ea\u56db\u672c\u8d26\uff1a\u4e3b\u673a\u7cfb\u7edf\u5b89\u88c5\u3001\u7ba1\u9053\u4e0e\u4fdd\u6e29\u3001\u672b\u7aef\u914d\u4ef6\u3001\u8bbe\u8ba1\u4e0e\u4eba\u5de5\u3002\u6309\u4e00\u62d6\u4e94\uff0b100\u33a1\u5730\u6696\u9010\u9879\u5217\u51fa\u89c4\u8303\u6210\u672c\u6784\u6210\uff0c\u5e76\u8bf4\u660e\u7b80\u5316\u914d\u7f6e\u80fd\u7701\u6389\u4ec0\u4e48\u3001\u7701\u4e86\u540e\u671f\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\u3002\u4ee5\u73b0\u573a\u52d8\u6d4b\u6b63\u5f0f\u62a5\u4ef7\u4e3a\u51c6\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=15911#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=15911"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=15911#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6c34\u673a\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u8fd9\u4e48\u591a\uff1a\u4e03\u9879\u5dee\u4ef7\u9010\u6761\u7b97\u7ed9\u4f60\u770b"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15911","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15911"}],"version-history":[{"count":5,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15911\/revisions"}],"predecessor-version":[{"id":16025,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15911\/revisions\/16025"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15911"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}