{"id":15994,"date":"2026-10-22T15:44:22","date_gmt":"2026-10-22T07:44:22","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=15994"},"modified":"2026-10-22T18:33:37","modified_gmt":"2026-10-22T10:33:37","slug":"%e6%88%90%e9%83%bd%e5%a4%a9%e5%ba%9c%e6%96%b0%e5%8c%ba%c2%b7%e6%97%a5%e7%ab%8b%e4%b8%a4%e8%81%94%e4%be%9b%e6%97%a5%e7%ab%8b%e7%a9%ba%e8%b0%83%e5%9c%b0%e6%9a%96%e6%a1%88%e4%be%8b","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=15994","title":{"rendered":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b"},"content":{"rendered":"\n\n<style>\n:root{\n  --deep-gold:#7a5a2e;\n  --gold:#c5a55a;\n  --gold-soft:#e9dcc0;\n  --white:#fff;\n  --bg:#f7f3ec;\n  --text-dark:#2e2a22;\n  --text-gray:#6b6256;\n  --text-light:#a89c86;\n  --toc-height:52px;\n  --card-radius:12px;\n  --shadow:0 4px 18px rgba(122,90,46,.10);\n}\n*{margin:0;padding:0;box-sizing:border-box}\nbody{font-family:\"Microsoft YaHei\",\"PingFang SC\",-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;color:var(--text-dark);background:var(--bg);line-height:1.75;font-size:16px}\na{color:var(--deep-gold);text-decoration:none}\n\n\/* ===== Hero ===== *\/\n.hero{position:relative;aspect-ratio:3\/1;max-height:420px;min-height:260px;display:flex;align-items:center;justify-content:center;background-color:#7a5a2e;background-image:url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p08-04.jpeg'),linear-gradient(135deg,#7a5a2e 0%,#a9853f 50%,#c5a55a 100%);background-size:cover;background-position:center;background-repeat:no-repeat;overflow:hidden;max-width:1352px;margin:0 auto 16px;border-radius:0;box-shadow:inset 0 -40px 80px rgba(0,0,0,0.28),inset 0 30px 60px rgba(255,255,255,0.08),0 10px 36px rgba(122,90,46,0.4)}\n.hero::before{content:'';position:absolute;inset:0;z-index:1;background:linear-gradient(135deg,rgba(80,60,25,0.32) 0%,rgba(122,90,46,0.18) 50%,rgba(197,165,90,0.22) 100%),radial-gradient(ellipse at 50% 35%,transparent 35%,rgba(0,0,0,0.20) 100%)}\n.hero-inner{position:relative;z-index:2;display:flex;flex-direction:column;align-items:center;justify-content:center;text-align:center;padding:20px;width:100%;max-width:760px}\n.hero-tagline{font-size:0.85rem;color:rgba(255,255,255,0.85);letter-spacing:2px;margin-bottom:10px}\n.hero-title{font-size:clamp(1.4rem,4vw,2.3rem);font-weight:700;color:#fff;margin-bottom:8px;text-shadow:0 2px 12px rgba(0,0,0,0.4);line-height:1.3}\n.hero-subtitle{font-size:clamp(0.9rem,2vw,1.15rem);color:rgba(255,255,255,0.92);margin-bottom:20px}\n.hero-date{font-size:0.75rem;color:rgba(255,255,255,0.6);margin-top:8px}\n.hero-info-card{display:flex;gap:18px;flex-wrap:wrap;justify-content:center;backdrop-filter:blur(12px);-webkit-backdrop-filter:blur(12px);background:rgba(255,255,255,0.16);border-radius:12px;padding:16px 24px;border:1px solid rgba(255,255,255,0.25)}\n.hero-info-item{text-align:center;min-width:90px}\n.hero-info-item .label{font-size:0.7rem;color:rgba(255,255,255,0.78);letter-spacing:1px;margin-bottom:3px}\n.hero-info-item .value{font-size:1.02rem;font-weight:700;color:#fff}\n\n\/* ===== \u7ffb\u8f6c\u5361\uff08\u6848\u4f8b\u6863\u6848 \/ \u7126\u70b9\u5173\u952e\u8bcd\u00b7\u6848\u4f8b\u6458\u8981\uff09 ===== *\/\n.flip-card{position:relative;max-width:1100px;margin:20px auto 0;perspective:1600px;cursor:pointer}\n.flip-inner{position:relative;display:grid;transition:transform .7s cubic-bezier(.4,.2,.2,1);transform-style:preserve-3d}\n.flip-card.flipped .flip-inner{transform:rotateY(180deg)}\n.flip-front,.flip-back{grid-area:1\/1;backface-visibility:hidden;-webkit-backface-visibility:hidden;background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);border:1px solid var(--gold-soft);border-top:3px solid var(--gold);padding:24px 30px}\n.flip-back{transform:rotateY(180deg);border-top-color:var(--deep-gold)}\n.flip-hint{text-align:center;font-size:12px;color:var(--text-light);margin-top:10px;letter-spacing:.5px}\n\n.focus-text{font-size:14px;line-height:1.9;color:var(--text-dark);text-align:justify;margin:0}\n.info-block{margin-bottom:18px;padding-bottom:14px;border-bottom:1px dashed #e6ddc8}\n.info-block:last-child{border-bottom:none;margin-bottom:0;padding-bottom:0}\n.info-block-h{font-size:0.92rem;font-weight:700;color:var(--gold);margin-bottom:10px;letter-spacing:.5px}\n.info-row{display:flex;gap:20px;flex-wrap:wrap;margin-bottom:10px}\n.info-cell{flex:1;min-width:130px}\n.info-cell .lbl{font-size:0.78rem;color:var(--text-gray);margin-bottom:2px}\n.info-cell .val{font-size:0.95rem;font-weight:600;color:var(--text-dark)}\n.quote{font-size:0.9rem;line-height:1.7;color:var(--text-dark);background:#fbf6ec;border-left:3px solid var(--gold);padding:12px 16px;border-radius:0 6px 6px 0;margin:0 0 16px}\n\n\/* ===== TOC ===== *\/\n.toc-wrapper{position:sticky;top:0;z-index:100;background:var(--white);border-bottom:1px solid #e0d8c8;height:var(--toc-height);display:flex;align-items:center;justify-content:center;max-width:1100px;margin:0 auto;padding:0 24px;-webkit-overflow-scrolling:touch}\n.toc{display:flex;gap:6px;min-width:max-content}\n.toc-btn{padding:6px 16px;border-radius:20px;font-size:13px;font-weight:600;cursor:pointer;border:1px solid #ddd;background:var(--white);color:var(--text-gray);transition:all .2s}\n.toc-btn.active,.toc-btn:hover{background:var(--deep-gold);color:var(--white);border-color:var(--deep-gold)}\n\n\/* ===== Sections ===== *\/\n.step-section{max-width:1100px;margin:24px auto;padding:0 24px}\n.step-head{display:flex;align-items:center;gap:10px;margin-bottom:16px}\n.step-num{display:inline-flex;align-items:center;justify-content:center;width:36px;height:36px;border-radius:50%;background:var(--deep-gold);color:var(--gold);font-size:16px;font-weight:700}\n.step-label{font-size:18px;font-weight:700;color:var(--deep-gold)}\n\n\/* ===== Section Tabs ===== *\/\n.section-tabs{display:flex;gap:4px;margin-bottom:16px;border-bottom:2px solid #e6ddc8;padding-bottom:0;flex-wrap:wrap}\n.section-tab{padding:8px 16px;font-size:13px;font-weight:600;cursor:pointer;border-bottom:2px solid transparent;color:var(--text-gray);transition:all .2s;margin-bottom:-2px}\n.section-tab.active{color:var(--deep-gold);border-bottom-color:var(--deep-gold)}\n\n\/* ===== Cards ===== *\/\n.content-card{background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);padding:24px 28px;margin-bottom:16px;border:1px solid #efe7d6}\n.card-title{font-size:16px;font-weight:700;color:var(--deep-gold);margin-bottom:10px}\n.card-desc{font-size:14px;color:var(--text-gray);line-height:1.7}\n.card-desc strong{color:var(--deep-gold)}\n\n\/* ===== Conclusion Bar ===== *\/\n.conclusion-bar{background:linear-gradient(90deg,#fbf3e2,#f6e8cf);border-left:4px solid var(--gold);border-radius:8px;padding:12px 16px;font-size:13.5px;color:#7a5a2e;font-weight:600;margin-bottom:16px;line-height:1.6}\n\n\/* ===== Info Table ===== *\/\n.info-table{width:100%;border-collapse:collapse;margin:12px 0}\n.info-table th{background:var(--deep-gold);color:var(--white);font-size:14px;font-weight:600;padding:10px 14px;text-align:left}\n.info-table td{font-size:14px;padding:10px 14px;border-bottom:1px solid #efe7d6}\n.info-table tr:nth-child(even) td{background:#fbf6ec}\n\n\/* ===== Compare Table ===== *\/\n.compare-table{width:100%;border-collapse:collapse;margin:12px 0}\n.compare-table th{font-size:13px;font-weight:600;padding:8px 12px;text-align:center}\n.compare-table td{font-size:13px;padding:8px 12px;text-align:center;border-bottom:1px solid #efe7d6}\n.compare-table .col-recommend{background:#fbf1dc;color:#7a5a2e;font-weight:600}\n.compare-table .col-normal{background:#f3efe8;color:#8a7d68;font-weight:600}\n.compare-table .col-header-b{background:var(--gold);color:var(--white)}\n.compare-table .col-header-a{background:var(--deep-gold);color:var(--white)}\n\n\/* ===== Tags ===== *\/\n.tag{display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;margin:2px}\n.tag.gold{background:rgba(197,165,90,.16);color:var(--deep-gold)}\n.tag.blue{background:rgba(122,90,46,.10);color:var(--deep-gold)}\n\n\/* ===== Promise Grid ===== *\/\n.promise-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:12px 0}\n.promise-card{background:var(--white);border-radius:8px;padding:16px;box-shadow:var(--shadow);text-align:center;border:1px solid #efe7d6}\n.promise-card .icon{font-size:24px;margin-bottom:6px}\n.promise-card .title{font-size:14px;font-weight:700;color:var(--deep-gold)}\n.promise-card .desc{font-size:12px;color:var(--text-gray)}\n\n\/* ===== FAQ ===== *\/\n.faq-item{background:var(--white);border-radius:8px;padding:16px;margin-bottom:10px;box-shadow:var(--shadow);border:1px solid #efe7d6}\n.faq-q{font-size:15px;font-weight:700;color:var(--deep-gold);margin-bottom:6px}\n.faq-a{font-size:14px;color:var(--text-gray);line-height:1.7}\n\n\/* ===== Cert Grid ===== *\/\n.cert-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(280px,1fr));gap:12px;margin:12px 0}\n.cert-item{text-align:center}\n.cert-item img{max-width:100%;border-radius:8px;box-shadow:var(--shadow);margin-bottom:6px}\n.cert-item .label{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Photo Grid ===== *\/\n.photo-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:10px;margin:14px 0}\n.photo-grid img{width:100%;height:auto;border-radius:6px;cursor:pointer;transition:transform .2s;display:block}\n.photo-grid img:hover{transform:scale(1.03)}\n.photo-item{margin:0}\n.photo-item figcaption{font-size:12px;color:var(--text-gray);text-align:center;margin-top:6px;line-height:1.45;padding:0 2px}\n.photo-phase{margin-bottom:16px}\n.photo-phase .phase-label{font-size:13px;font-weight:700;color:var(--deep-gold);margin-bottom:6px}\n.photo-count{font-size:11px;color:var(--text-light)}\n\n\/* ===== Timeline ===== *\/\n.timeline{margin:16px 0}\n.timeline-step{display:flex;gap:12px;margin-bottom:12px;align-items:flex-start}\n.timeline-dot{width:12px;height:12px;border-radius:50%;background:var(--gold);margin-top:4px;flex-shrink:0}\n.timeline-label{font-size:13px;font-weight:700;color:var(--deep-gold);min-width:100px}\n.timeline-detail{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Advantage Grid ===== *\/\n.advantage-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(220px,1fr));gap:12px;margin:12px 0}\n.advantage-card{background:var(--white);border-radius:8px;padding:16px;box-shadow:var(--shadow);text-align:center;border:1px solid #efe7d6}\n.advantage-card .icon{font-size:22px;color:var(--gold);margin-bottom:4px}\n.advantage-card .title{font-size:14px;font-weight:700;color:var(--deep-gold)}\n.advantage-card .desc{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Store Card ===== *\/\n.store-card{background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);overflow:hidden;margin-bottom:12px;border:1px solid #efe7d6}\n.store-card img{width:100%;height:180px;object-fit:cover}\n.store-card .store-info{padding:14px}\n.store-card .store-name{font-size:14px;font-weight:700;color:var(--deep-gold)}\n.store-card .store-addr{font-size:12px;color:var(--text-gray)}\n\n\/* ===== Highlight ===== *\/\n.highlight{color:var(--deep-gold);font-weight:700}\n\n\/* ===== Disclaimer ===== *\/\n.disclaimer{background:#fbf6ec;border-radius:8px;padding:16px;margin:12px 0;font-size:12px;color:var(--text-light);border:1px dashed #d8c9a8}\n\n\/* ===== Keywords Hidden ===== *\/\n.keywords-block{display:none;font-size:0;color:transparent}\n\n\/* ===== \u5916\u94fe\u80f6\u56ca ===== *\/\n.ext-link{display:inline-block;padding:8px 16px;margin:6px 8px 6px 0;border:1px solid var(--gold);border-radius:22px;font-size:13px;font-weight:600;color:var(--deep-gold);background:rgba(197,165,90,.08);transition:all .2s}\n.ext-link:hover{background:var(--gold);color:#fff}\n\n\/* ===== Responsive ===== *\/\n@media(max-width:768px){\n  .hero-title{font-size:24px}\n  .hero-info-card{flex-direction:column;gap:6px}\n  .step-section{padding:0 16px}\n  .photo-grid{grid-template-columns:repeat(2,1fr)}\n  .info-row{flex-direction:column}\n  .compare-table{font-size:11px}\n  .promise-grid{grid-template-columns:repeat(2,1fr)}\n  .advantage-grid{grid-template-columns:repeat(2,1fr)}\n  .cert-grid{grid-template-columns:1fr}\n  .timeline-step{flex-direction:column}\n  .content-card{padding:18px 20px}\n  .section-tabs{flex-wrap:wrap}\n}\n@media(max-width:480px){\n  .hero-title{font-size:20px}\n  .photo-grid{grid-template-columns:1fr}\n  .toc-btn{padding:4px 10px;font-size:12px}\n}\n<\/style>\n<style>\n\/* \u8fde\u8fde\u770b\u5bb9\u5668\u6837\u5f0f *\/\n.llk-wrap {max-width:1100px;margin:2rem auto;padding:1.5rem;background:#f8f9fa;border-radius:12px;}\n.llk-title {text-align:center;font-size:18px;font-weight:bold;margin-bottom:20px;color:#222;}\n.llk-container {display:grid;grid-template-columns:1fr 60px 1fr;gap:16px;align-items:start;}\n.llk-col {}\n.llk-item {padding:12px 16px;margin:10px 0;border-radius:8px;color:#fff;cursor:pointer;transition:0.25s ease;user-select:none;opacity:0.85;}\n.llk-item:hover {opacity:1;transform:translateX(3px);}\n.llk-item.selected {outline:3px solid #000;opacity:1;}\n.llk-item.match-done {opacity:0.35;pointer-events:none;}\n.llk-middle {position:relative;min-height:320px;}\n.llk-line {position:absolute;height:3px;background:#666;transform-origin:left center;display:none;}\n.llk-desc-box {margin-top:6px;padding:8px 12px;background:#fff;border-radius:6px;font-size:14px;color:#333;display:none;}\n.llk-finish-tip {text-align:center;margin-top:24px;padding:12px;background:#dff0d8;color:#2b542c;border-radius:8px;display:none;font-weight:bold;}\n\/* \u53f3\u4fa7\u65b9\u6848\u9ed8\u8ba4\u9690\u85cf\u6587\u5b57\uff0c\u70b9\u51fb\uff08\u9009\u4e2d\/\u5339\u914d\uff09\u540e\u6d6e\u73b0 *\/\n.llk-col.right-col .llk-item .llk-label { display: none; }\n.llk-col.right-col .llk-item.selected .llk-label,\n.llk-col.right-col .llk-item.match-done .llk-label { display: block; }\n.llk-col.right-col .llk-item { min-height: 46px; display:flex; align-items:center; justify-content:center; text-align:center; }\n.llk-col.right-col .llk-item.selected,\n.llk-col.right-col .llk-item.match-done { justify-content:flex-start; text-align:left; }\n<\/style>\n<style>\n\/* ===== \u7ffb\u8f6c\u5361\u5185\u5bb9\u6392\u7248\u8865\u4e01 ===== *\/\n.archive-card h3{margin:0 0 14px;font-size:1.15rem;color:var(--deep-gold);border-bottom:1px solid var(--gold-soft);padding-bottom:10px}\n.info-grid{display:grid;grid-template-columns:repeat(4,1fr);gap:10px}\n@media(max-width:900px){.info-grid{grid-template-columns:repeat(2,1fr)}}\n.info-grid .info-cell{background:#faf6ec;border:1px solid var(--gold-soft);border-radius:10px;padding:10px 12px;min-width:0}\n.info-grid .info-cell .lbl{font-size:0.75rem;color:var(--text-gray);margin-bottom:4px}\n.info-grid .info-cell .val{font-size:0.88rem;font-weight:600;color:var(--text-dark);line-height:1.55}\n.kw-row{display:flex;flex-wrap:wrap;gap:8px;margin-bottom:14px}\n.kw-tag{display:inline-block;padding:5px 13px;border-radius:16px;background:var(--gold-soft);color:var(--deep-gold);font-size:0.82rem;font-weight:600;border:1px solid var(--gold)}\n.abstract{font-size:0.92rem;line-height:1.9;color:var(--text-gray);margin:0;text-align:justify}\n\/* ===== \u9700\u6c42\u8bca\u65ad\u5927\u677f\u5757\uff08\u53c2\u8003\uff1a\u8bc9\u6c42\u2194\u8bca\u65ad\u4e24\u5217\u8868\u683c + \u9690\u85cf\u9700\u6c42\u6e05\u5355\uff09 ===== *\/\n.diag-title{font-size:1.25rem;font-weight:700;color:var(--deep-gold);margin:26px 0 14px;padding-left:12px;border-left:4px solid var(--gold)}\n.diag-table{width:100%;border-collapse:collapse;background:var(--white);border-radius:var(--card-radius);overflow:hidden;box-shadow:var(--shadow);font-size:0.95rem}\n.diag-table th{background:linear-gradient(135deg,var(--deep-gold),var(--gold));color:#fff;padding:13px 16px;text-align:left;font-size:0.98rem}\n.diag-table td{padding:13px 16px;border-bottom:1px solid #f0e8d8;color:var(--text-dark);line-height:1.7;vertical-align:top}\n.diag-table tr:last-child td{border-bottom:none}\n.diag-table td.claim{font-weight:600;color:var(--deep-gold);white-space:nowrap}\n.diag-list{list-style:none;margin:0;padding:0;background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow);border:1px solid var(--gold-soft)}\n.diag-list li{padding:13px 18px;border-bottom:1px solid #f0e8d8;font-size:0.95rem;line-height:1.8;color:var(--text-dark)}\n.diag-list li:last-child{border-bottom:none}\n.diag-list li::before{content:\"\u2714\";color:var(--gold);font-weight:700;margin-right:10px}\n.diag-list li strong{color:var(--deep-gold)}\n<\/style>\n\n<!-- ===== \u82f1\u96c4\u680f ===== -->\n<section class=\"hero\" id=\"hero\">\n  <div class=\"hero-inner\">\n    <div class=\"hero-tagline\">\u9f99\u8109\u6696\u901a \u00b7 2004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6 \u00b7 \u771f\u5b9e\u6848\u4f8b\u5b9e\u6d4b<\/div>\n    <h2 class=\"hero-title\">\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8<br>\u5218\u8001\u5e08 \u65e5\u7acbVAM mini II\u4e2d\u592e\u7a7a\u8c03 + \u6c34\u5730\u6696\u6848\u4f8b<\/h2>\n    <p class=\"hero-subtitle\">\u4e24\u5c42\u8dc3\u5c42\u5206\u5c42\u914d\u7f6e \u00b7 \u53cc\u5916\u673a\uff08\u6bcf\u5c421\u53f0\uff09+ 6\u53f0\u76f4\u6d41\u53d8\u9891\u5185\u673a \u00b7 159.5\u33a1\u6c34\u5730\u669610\u56de\u8def \u00b7 \u745e\u7f8e\u51b7\u51dd\u7089+\u96f6\u51b7\u6c34\u70ed\u6c34 \u00b7 \u4e00\u671f\u9690\u853d\u5de5\u7a0b\u5b9e\u5f55<\/p>\n    <div class=\"hero-info-card\">\n      <div class=\"hero-info-item\"><div class=\"label\">\u697c\u76d8<\/div><div class=\"value\">\u5929\u5e9c\u65b0\u533a<br>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u6237\u578b<\/div><div class=\"value\">\u4e24\u5c42\u8dc3\u5c42<br>\u53e0\u62fc\u4f4f\u5b85<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u7a7a\u8c03<\/div><div class=\"value\">VAM mini II<br>2\u62d66<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u5730\u6696<\/div><div class=\"value\">159.5\u33a1<br>10\u56de\u8def<\/div><\/div>\n      <div class=\"hero-info-item\"><div class=\"label\">\u5f62\u5f0f<\/div><div class=\"value\">\u9690\u853d\u5de5\u7a0b<br>\u6c2e\u4fdd\u710a\u63a5<\/div><\/div>\n    <\/div>\n    <p class=\"hero-date\">\u66f4\u65b0\uff1a2026\u5e7410\u6708\uff08\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u9636\u6bb5\uff09<\/p>\n  <\/div>\n<\/section>\n\n<!-- ===== \u7ffb\u8f6c\u5361\uff08\u6848\u4f8b\u6863\u6848 \/ \u7126\u70b9\u5173\u952e\u8bcd\u00b7\u6848\u4f8b\u6458\u8981\uff09 ===== -->\n<section class=\"flip-card\" id=\"case-flip\" onclick=\"this.classList.toggle('flipped')\">\n  <div class=\"flip-inner\">\n    <div class=\"flip-face flip-front\">\n      <div class=\"archive-card\">\n        <h3>\ud83d\udccb \u6848\u4f8b\u6863\u6848<\/h3>\n        <div class=\"info-grid\">\n          <div class=\"info-cell\"><div class=\"lbl\">\u697c\u76d8<\/div><div class=\"val\">\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\uff08\u5929\u5e9c\u65b0\u533a\uff09<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u6237\u578b<\/div><div class=\"val\">\u4e24\u5c42\u8dc3\u5c42 \u00b7 \u53e0\u62fc\u4f4f\u5b85<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u4e00\u5c42\u7a7a\u8c03<\/div><div class=\"val\">RAS-140FSVN7Q \u00d71<br>RPIZ-71(\u5ba2\u9910\u5385)+56(\u5ba2\u9910\u5385)+25(\u5367\u5ba4)<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u4e8c\u5c42\u7a7a\u8c03<\/div><div class=\"val\">RAS-140FSVN7Q \u00d71<br>RPIZ-56(\u4e3b\u5367)+28(\u6b21\u5367)+56(\u6b21\u5367)<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u5730\u6696<\/div><div class=\"val\">159.5\u33a1 \/ 10\u56de\u8def<br>\uff08\u6bcf\u5c425\u8def\u5206\u96c6\u6c34\u5668\uff09<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u70ed\u6c34<\/div><div class=\"val\">\u745e\u7f8e\u51b7\u51dd\u7089LL1GBQ24-CBX1-30<br>+\u96f6\u51b7\u6c34JSQ32-GTE11\uff0816\u5347\uff09<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u987e\u95ee<\/div><div class=\"val\">\u8303\u4e3d\u5982\uff08\u5357\u5bcc\u68ee\u5e97\uff09<\/div><\/div>\n          <div class=\"info-cell\"><div class=\"lbl\">\u65bd\u5de5\u65b9<\/div><div class=\"val\">\u9f99\u8109\u6696\u901a\u30012004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6<\/div><\/div>\n        <\/div>\n        <div class=\"flip-hint\">\ud83d\udc46 \u70b9\u51fb\u5361\u7247\u7ffb\u9762 \u00b7 \u67e5\u770b\u7126\u70b9\u5173\u952e\u8bcd \u00b7 \u6848\u4f8b\u6458\u8981<\/div>\n      <\/div>\n    <\/div>\n    <div class=\"flip-face flip-back\">\n      <div class=\"archive-card\">\n        <h3>\ud83d\udccc \u7126\u70b9\u5173\u952e\u8bcd \u00b7 \u6848\u4f8b\u6458\u8981<\/h3>\n        <div class=\"kw-row\">\n          <span class=\"kw-tag\">\u5929\u5e9c\u65b0\u533a<\/span><span class=\"kw-tag\">\u4e07\u79d1\u5929\u5e9c\u540d\u90b8<\/span><span class=\"kw-tag\">\u4e24\u5c42\u8dc3\u5c42<\/span>\n          <span class=\"kw-tag\">\u65e5\u7acbVAM mini II<\/span><span class=\"kw-tag\">\u53cc\u5916\u673a\u5206\u5c42<\/span><span class=\"kw-tag\">\u4e00\u62d6\u591a<\/span>\n          <span class=\"kw-tag\">\u76f4\u6d41\u53d8\u9891\u5185\u673a<\/span><span class=\"kw-tag\">159.5\u33a1\u5730\u6696<\/span><span class=\"kw-tag\">10\u56de\u8def<\/span>\n          <span class=\"kw-tag\">\u745e\u7f8e\u51b7\u51dd\u7089<\/span><span class=\"kw-tag\">\u4e00\u7ea7\u80fd\u6548<\/span><span class=\"kw-tag\">\u96f6\u51b7\u6c34\u70ed\u6c34<\/span>\n          <span class=\"kw-tag\">\u5206\u5c42\u5206\u533a\u63a7\u5236<\/span><span class=\"kw-tag\">\u6c2e\u6c14\u4fdd\u62a4\u710a<\/span><span class=\"kw-tag\">\u7cfb\u7edf\u4fdd\u538b<\/span>\n        <\/div>\n        <p class=\"abstract\">\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u5218\u8001\u5e08\u5bb6\u4e3a\u4e24\u5c42\u8dc3\u5c42\uff08\u4e00\u5c42\u5ba2\u9910\u5385+\u5367\u5ba4\u3001\u4e8c\u5c42\u4e3b\u5367+\u6b21\u5367\u00d72\uff09\u3002\u9f99\u8109\u6696\u901a\u30012004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u7a7a\u8c03\u91c7\u7528\u65e5\u7acbVAM mini II\u4e24\u53f0\u5916\u673a\u5206\u5c42\u914d\u7f6e\uff08\u6bcf\u5c421\u53f0RAS-140FSVN7Q\uff09\uff0c\u4e00\u697c\u5916\u673a\u5e26\u516c\u533a\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c6\u53f0\u76f4\u6d41\u53d8\u9891\u5185\u673a\u6309\u623f\u95f4\u8d1f\u8377\u5339\u914d\uff1b\u5730\u6696\u8986\u76d6159.5\u33a1\u517110\u56de\u8def\uff0c\u70ed\u6e90\u914d\u745e\u7f8e\u8fdb\u53e3\u51b7\u51dd\u7089LL1GBQ24-CBX1-30\uff08\u91c7\u6696\u4e00\u7ea7\u80fd\u6548\uff09\uff0c\u751f\u6d3b\u70ed\u6c34\u914d\u745e\u7f8e\u96f6\u51b7\u6c34\u70ed\u6c34\u5668JSQ32-GTE11\uff0816\u5347\uff09+\u5faa\u73af\u6cf5\uff0c\u91c7\u6696\u4e0e\u70ed\u6c34\u53cc\u4e00\u7ea7\u80fd\u6548\uff1b\u8fdb\u573a\u5b9a\u4f4d\u65f6\u56e0\u71c3\u6c14\u65e0\u6cd5\u4e0a\u4e8c\u697c\uff0c\u73b0\u573a\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5\u65b9\u6848\u3002\u672c\u6848\u4ee5\"\u6c2e\u6c14\u4fdd\u62a4\u710a+\u7cfb\u7edf\u4fdd\u538b+\u5206\u5c42\u7cbe\u51c6\u914d\u7f6e\"\u843d\u5730\uff0c\u63d0\u4f9b\u5929\u5e9c\u65b0\u533a\u53ca\u5468\u8fb9\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u7a7a\u8c03\u5730\u6696\u5b9a\u5236\u65b9\u6848\uff0c\u672c\u571f\u7cbe\u5de5\u65bd\u5de5\u3002<\/p>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== TOC \u7ae0\u8282\u5bfc\u822a ===== -->\n<div class=\"toc-wrapper\">\n  <div class=\"toc-grid\">\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s1')\">S1 \u5ba2\u6237\u76ee\u6807<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s2')\">S2 \u9700\u6c42\u8bca\u65ad<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s3')\">S3 \u65b9\u6848\u6210\u672c<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s4')\">S4 \u65bd\u5de5\u4ea4\u4ed8<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s5')\">S5 \u9a8c\u8bc1\u8fed\u4ee3<\/button>\n    <button class=\"toc-btn\" onclick=\"scrollToSection('s6')\">S6 \u95e8\u5e97\u6388\u6743<\/button>\n  <\/div>\n<\/div>\n\n<!-- ============================================================ -->\n<!-- S1 \u00b7 \u5ba2\u6237\u6210\u529f\u76ee\u6807 -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s1\">\n  <div class=\"step-head\"><span class=\"step-num\">S1<\/span><span class=\"step-label\">\u5ba2\u6237\u6210\u529f\u76ee\u6807<\/span><\/div>\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s1-tab1')\">\u5ba2\u6237\u4fe1\u606f\u5361<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s1-tab2')\">\u8212\u9002\u76ee\u6807<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s1-tab3')\">\u7cfb\u7edf\u603b\u89c8<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s1-tab4')\">\u670d\u52a1\u7406\u5ff5<\/div>\n  <\/div>\n\n  <div id=\"s1-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83c\udfe0 \u6848\u4f8b\u6982\u51b5\uff1a\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u4e24\u5c42\u8dc3\u5c42\uff0c\u65e5\u7acbVAM mini II\u4e2d\u592e\u7a7a\u8c03\uff082\u62d66\uff09+ 159.5\u33a1\u6c34\u5730\u6696\uff0810\u56de\u8def\uff09\uff0c\u4e00\u671f\u9690\u853d\u5de5\u7a0b2026\u5e7410\u6708\u8fdb\u573a\u65bd\u5de5\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udccb \u5ba2\u6237\u4fe1\u606f\u5361<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><td>\u697c\u76d8<\/td><td>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\uff08\u5929\u5e9c\u65b0\u533a\u00b7\u53e0\u62fc\u793e\u533a\uff09<\/td><\/tr>\n        <tr><td>\u6237\u578b<\/td><td>\u4e24\u5c42\u8dc3\u5c42\uff1a\u4e00\u5c42\u5ba2\u9910\u5385+\u5367\u5ba4\uff0c\u4e8c\u5c42\u4e3b\u5367+\u6b21\u5367\u00d72<\/td><\/tr>\n        <tr><td>\u7a7a\u8c03\u7cfb\u7edf<\/td><td>\u65e5\u7acb VAM mini II \u7eaf\u6c1f\u4e2d\u592e\u7a7a\u8c03 \u00b7 2\u53f0\u5916\u673a\u5206\u5c42 + 6\u53f0\u5185\u673a<\/td><\/tr>\n        <tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u6c34\u5730\u6696 159.5\u33a1 \u00b7 10\u56de\u8def\uff08\u6bcf\u5c425\u8def\u5206\u96c6\u6c34\u5668\uff09<\/td><\/tr>\n        <tr><td>\u7ebf\u63a7\u5668<\/td><td>\u65e5\u7acb WIFI\u7ebf\u63a7\u5668 PC-P1HVQA \u00d7 6\uff08\u4e0e\u5185\u673a\u4e00\u4e00\u5bf9\u5e94\uff09<\/td><\/tr>\n        <tr><td>\u65bd\u5de5\u9636\u6bb5<\/td><td>\u4e00\u671f\u9690\u853d\u5de5\u7a0b\uff082026\u5e7410\u670814\u65e5\u8fdb\u573a\uff09<\/td><\/tr>\n        <tr><td>\u9500\u552e\u987e\u95ee<\/td><td>\u8303\u4e3d\u5982\uff08\u5357\u5bcc\u68ee\u5e97\uff09<\/td><\/tr>\n        <tr><td>\u65bd\u5de5\u65b9<\/td><td>\u9f99\u8109\u6696\u901a\u30012004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s1-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83c\udfaf \u8212\u9002\u76ee\u6807\uff1a\u4e24\u5c42\u8dc3\u5c42\u5168\u5c4b\u51b7\u6696\u517c\u987e\u2014\u2014\u590f\u5b63\u5206\u5c42\u5236\u51b7\u3001\u51ac\u5b63\u5730\u6696\u8f90\u5c04\u4f9b\u6696\uff0c\u5404\u623f\u95f4\u72ec\u7acb\u63a7\u5236\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83c\udf21\ufe0f \u8212\u9002\u76ee\u6807<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u590f\u5b63\u5206\u5c42\u5236\u51b7<\/strong>\uff1a\u4e24\u5c42\u5404\u914d1\u53f0\u5916\u673a\uff0c6\u53f0\u76f4\u6d41\u53d8\u9891\u5185\u673a\u6309\u623f\u95f4\u8d1f\u8377\u7cbe\u51c6\u5339\u914d\uff0c\u5ba2\u9910\u5385\u5927\u7a7a\u95f4\u4e0e\u5367\u5ba4\u5c0f\u7a7a\u95f4\u5404\u5f97\u5176\u6240\uff1b<br>\n        \u2461 <strong>\u51ac\u5b63\u5730\u6696\u4f9b\u6696<\/strong>\uff1a159.5\u33a1\u6c34\u5730\u669610\u56de\u8def\uff0c\u8f90\u5c04\u4f9b\u6696\u811a\u611f\u8212\u9002\u3001\u6e29\u5ea6\u5747\u5300\uff1b<br>\n        \u2462 <strong>\u5206\u5ba4\u72ec\u7acb\u63a7\u5236<\/strong>\uff1a6\u53f0\u5185\u673a+\u5730\u6696\u5404\u56de\u8def\u5206\u5ba4\u8c03\u8282\uff0c\u5e38\u7528\u623f\u95f4\u4f18\u5148\u3001\u95f2\u7f6e\u623f\u95f4\u8282\u80fd\uff1b<br>\n        \u2463 <strong>\u667a\u80fd\u64cd\u63a7<\/strong>\uff1aWIFI\u7ebf\u63a7\u5668\u652f\u6301\u8fdc\u7a0b\u63a7\u5236\uff0c\u56de\u5bb6\u524d\u9884\u51b7\u9884\u70ed\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s1-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u7cfb\u7edf\u603b\u89c8\uff1a\u7a7a\u8c03\uff08\u6c1f\u7cfb\u7edf\uff09\u3001\u5730\u6696+\u70ed\u6c34\uff08\u745e\u7f8e\u51b7\u51dd\u7089\/\u70ed\u6c34\u5668\u6c34\u7cfb\u7edf\uff09\u5404\u81ea\u72ec\u7acb\u8fd0\u884c\u3001\u4e92\u4e0d\u5f71\u54cd\uff0c\u5404\u6309\u5408\u9002\u5de5\u51b5\u9ad8\u6548\u5de5\u4f5c\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\udde9 \u4e09\u7cfb\u7edf\u603b\u89c8<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u7cfb\u7edf<\/th><th>\u5f62\u5f0f<\/th><th>\u914d\u7f6e\u8981\u70b9<\/th><\/tr>\n        <tr><td>\u2744\ufe0f \u7a7a\u8c03<\/td><td>\u65e5\u7acb VAM mini II \u7eaf\u6c1f\u591a\u8054\u673a\uff082\u62d66\uff09<\/td><td>\u4e24\u53f0RAS-140FSVN7Q\u5916\u673a\u5206\u5c42\u8bbe\u7f6e\uff08\u4e00\u5c421\u53f0+\u4e8c\u5c421\u53f0\uff09\uff0c\u4e00\u697c\u5916\u673a\u5e26\u516c\u533a\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c\u8fde\u63a5\u7387\u4e00\u5c42108.6%\u3001\u4e8c\u5c42100.0%<\/td><\/tr>\n        <tr><td>\ud83d\udd25 \u5730\u6696<\/td><td>\u6c34\u5730\u6696\uff08\u51b7\u51dd\u7089\u70ed\u6e90\uff09<\/td><td>159.5\u33a1 \/ 10\u56de\u8def\uff0c\u6bcf\u5c425\u8def\u5206\u96c6\u6c34\u5668\uff0cDe20\u76d8\u7ba1\u3001\u6807\u51c6\u95f4\u8ddd\u5e03\u7f6e\uff1b\u745e\u7f8eLL1GBQ24-CBX1-30\u5168\u9884\u6df7\u51b7\u51dd\u7089\u4f9b\u70ed\uff0c\u91c7\u6696\u4e00\u7ea7\u80fd\u6548<\/td><\/tr>\n        <tr><td>\ud83d\udebf \u70ed\u6c34<\/td><td>\u96f6\u51b7\u6c34\u71c3\u6c14\u70ed\u6c34\u5668 + \u5faa\u73af\u6cf5<\/td><td>\u745e\u7f8eJSQ32-GTE11\uff0816\u5347\uff09\u4e00\u7ea7\u80fd\u6548\uff0c\u914d\u5faa\u73af\u6cf5\u5b9e\u73b0\u5373\u5f00\u5373\u70ed\uff1b\u8fdb\u573a\u5b9a\u4f4d\u65f6\u56e0\u71c3\u6c14\u65e0\u6cd5\u4e0a\u4e8c\u697c\uff0c\u7531\u539f\"\u4e8c\u697c\u5355\u72ec\u88c5\u70ed\u6c34\u5668\"\u73b0\u573a\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5<\/td><\/tr>\n        <tr><td>\ud83c\udf9b\ufe0f \u63a7\u5236<\/td><td>WIFI\u7ebf\u63a7\u5668 \u00d7 6 + \u5206\u5c42\u5206\u533a\u63a7\u5236<\/td><td>\u7a7a\u8c03\u697c\u4e0a\u697c\u4e0b\u5206\u5c42\u63a7\u5236\u3001\u5404\u623f\u95f4\u72ec\u7acb\u5f00\u5173\u8c03\u6e29\uff0c\u5730\u6696\u5206\u56de\u8def\u63a7\u5236<\/td><\/tr>\n      <\/tbody><\/table>\n      <div class=\"disclaimer\" style=\"margin-top:10px\">\u26a0\ufe0f \u8bda\u5b9e\u62ab\u9732\uff1a\u9505\u7089\u4e0e\u70ed\u6c34\u5668\u578b\u53f7\u4ee5\u5ba2\u6237\u5408\u540c\u4e3a\u51c6\uff08\u745e\u7f8eLL1GBQ24-CBX1-30\u51b7\u51dd\u7089\u00d71\u53f0\u3001\u745e\u7f8eJSQ32-GTE11\u96f6\u51b7\u6c34\u70ed\u6c34\u566816\u5347\u00d71\u53f0\uff09\uff1b\u672c\u9875\u7a7a\u8c03\u914d\u7f6e\u4e3a\u65e5\u7acbVAM mini II\u5b9a\u7a3f\u6570\u636e\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s1-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udccb \u670d\u52a1\u7406\u5ff5\uff1a\u4ee5\"\u52d8\u6d4b\u7cbe\u51c6+\u914d\u7f6e\u900f\u660e+\u7cbe\u5de5\u9690\u853d+\u8282\u70b9\u7559\u8bc1\"\u670d\u52a1\u8dc3\u5c42\u4e1a\u4e3b\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83e\udd1d \u9f99\u8109\u670d\u52a1\u7406\u5ff5<\/div>\n      <div class=\"card-desc\">\n        \u9762\u5bf9\u8dc3\u5c42\u5927\u6237\u578b\u4e1a\u4e3b\uff0c\u9f99\u8109\u6696\u901a\uff1a\u2460 \u628a\u7a7a\u8c03\u4e24\u8054\u4f9b\/\u6c1f\u673a+\u9505\u7089\u5730\u6696\u7684\u5f62\u5f0f\u5dee\u5f02\u3001\u521d\u88c5\u4e0e\u8fd0\u884c\u6210\u672c\u8bb2\u900f\uff0c\u4e00\u6b21\u6027\u8bf4\u6e05\uff1b\u2461 \u7528<strong>\u6c2e\u6c14\u4fdd\u62a4\u710a+\u7cfb\u7edf\u4fdd\u538b+\u53cc\u87ba\u6bcd\u51cf\u9707\u540a\u88c5<\/strong>\u7684\u7cbe\u5de5\u6807\u51c6\uff0c\u628a\"\u9690\u853d\u5de5\u7a0b\"\u53d8\u6210\"\u53ef\u7559\u8bc1\u3001\u53ef\u5de1\u68c0\"\u7684\u900f\u660e\u8282\u70b9\uff1b\u2462 \u6bcf\u5c42\u72ec\u7acb\u5916\u673a\u5206\u5c42\u914d\u7f6e\uff0c\u914d\u5408WIFI\u7ebf\u63a7\u5668\uff0c\u8ba9\u4e24\u5c42\u7a7a\u95f4\u5404\u81ea\u8212\u9002\u3001\u6309\u9700\u8282\u80fd\uff1b\u2463 \u6bcf\u4e00\u6b65\u710a\u63a5\u3001\u540a\u88c5\u3001\u4fdd\u538b\u90fd\u62cd\u7167\u7559\u6863\uff0c\u8ba9\u4e1a\u4e3b\u81ea\u5df1\u770b\u89c1\"\u6ca1\u5077\u5de5\u51cf\u6599\"\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u8fde\u8fde\u770b\uff1a\u75db\u70b9\u4e0e\u89e3\u51b3\u65b9\u6848 ===== -->\n<div class=\"llk-wrap\">\n  <div class=\"llk-title\">\u75db\u70b9\u4e0e\u89e3\u51b3\u65b9\u6848\u8fde\u8fde\u770b\uff08\u70b9\u51fb\u5339\u914d\u76f8\u540c\u989c\u8272\uff09<\/div>\n  <div class=\"llk-container\">\n    <div class=\"llk-col left-col\" id=\"leftBox\">\n      <!-- \u5de6\u4fa7\uff1a\u5218\u8001\u5e08\u771f\u5b9e\u75db\u70b9\uff08\u6765\u81ea\u6c9f\u901a\u8bb0\u5f55\uff09 -->\n      <div class=\"llk-item\" data-color=\"#e74c3c\" data-target=\"p1\">\n        \ud83d\udca1 \u975e\u5e38\u770b\u91cd\u8282\u80fd\u6027\uff0c\u62c5\u5fc3\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u4e09\u5957\u7cfb\u7edf\u540e\u671f\u4f7f\u7528\u8d39\u9ad8\n        <div class=\"llk-desc-box\">\u80fd\u6e90\u8d26\u8981\u5148\u7b97\u6e05\uff1a\u5218\u8001\u5e08\u628a\"\u957f\u671f\u4f7f\u7528\u6210\u672c\"\u653e\u5728\u7b2c\u4e00\u4f4d\uff0c\u8981\u6c42\u51b7\u6696\u70ed\u6c34\u5168\u7cfb\u7edf\u90fd\u8981\u7701<\/div>\n      <\/div>\n      <div class=\"llk-item\" data-color=\"#3498db\" data-target=\"p2\">\n        \ud83d\udebf \u751f\u6d3b\u70ed\u6c34\u9700\u6c42\u5927\uff0c\u4e24\u5c42\u90fd\u60f3\u4e00\u5f00\u5c31\u6709\u70ed\u6c34\n        <div class=\"llk-desc-box\">\u539f\u8ba1\u5212\u4e8c\u697c\u5355\u72ec\u88c5\u4e00\u53f0\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u4f46\u71c3\u6c14\u7ba1\u9053\u65e0\u6cd5\u6539\u5230\u4e8c\u697c\uff0c\u539f\u65b9\u6848\u843d\u5730\u53d7\u963b<\/div>\n      <\/div>\n      <div class=\"llk-item\" data-color=\"#27ae60\" data-target=\"p3\">\n        \ud83c\udfe0 \u4e24\u5c42\u8dc3\u5c42\uff0c\u62c5\u5fc3\u4e00\u5c42\u51b7\u4e8c\u5c42\u70ed\u3001\u5206\u533a\u63a7\u5236\u4e0d\u7cbe\u51c6\n        <div class=\"llk-desc-box\">\u52a8\u533a\uff08\u5ba2\u9910\u5385\uff09\u548c\u9759\u533a\uff08\u5367\u5ba4\uff09\u4f7f\u7528\u65f6\u6bb5\u4e0d\u540c\uff0c\u5e0c\u671b\u697c\u4e0a\u697c\u4e0b\u5404\u81ea\u72ec\u7acb\u63a7\u5236<\/div>\n      <\/div>\n      <div class=\"llk-item\" data-color=\"#f39c12\" data-target=\"p4\">\n        \ud83d\udd27 \u9690\u853d\u5de5\u7a0b\u5728\u540a\u9876\u91cc\uff0c\u62c5\u5fc3\u65bd\u5de5\u8d28\u91cf\u770b\u4e0d\u89c1\u3001\u540e\u671f\u51fa\u95ee\u9898\n        <div class=\"llk-desc-box\">\u8dc3\u5c42\u540a\u9876\u9762\u79ef\u5927\uff0c\u710a\u63a5\u3001\u4fdd\u538b\u7b49\u9690\u853d\u5de5\u827a\u5fc5\u987b\u53ef\u7559\u8bc1\u3001\u53ef\u5de1\u68c0<\/div>\n      <\/div>\n    <\/div>\n    <div class=\"llk-middle\" id=\"lineArea\"><\/div>\n    <div class=\"llk-col right-col\" id=\"rightBox\">\n      <!-- \u53f3\u4fa7\u65b9\u6848\u3010\u523b\u610f\u6253\u4e71\u987a\u5e8f\uff1b\u9ed8\u8ba4\u9690\u85cf\u6587\u5b57\uff0c\u70b9\u51fb\u540e\u6d6e\u73b0\u3011 -->\n      <div class=\"llk-item\" data-color=\"#27ae60\" data-target=\"p3\">\n        <span class=\"llk-label\">\u53cc\u5916\u673a\u5206\u5c42\u5206\u533a\u63a7\u5236<\/span>\n        <div class=\"llk-desc-box\">\u4e24\u53f0RAS-140FSVN7Q\u6bcf\u5c421\u53f0\uff1a\u4e00\u697c\u5916\u673a\u5e26\u516c\u533a\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c\u5206\u533a\u7cbe\u51c6\u3001\u6309\u9700\u8fd0\u884c\u66f4\u8282\u80fd<\/div>\n      <\/div>\n      <div class=\"llk-item\" data-color=\"#f39c12\" data-target=\"p4\">\n        <span class=\"llk-label\">\u6c2e\u6c14\u4fdd\u62a4\u710a+\u4fdd\u538b\u7559\u8bc1<\/span>\n        <div class=\"llk-desc-box\">\u9f99\u715c\u7d2b\u94dc\u7ba1\u5145\u6c2e\u4fdd\u62a4\u710a\u9632\u6c27\u5316\u76ae\uff0cR410A\u7cfb\u7edf\u4fdd\u538b\u68c0\u6f0f\uff0c\u6c34\u5370\u76f8\u673a\u5168\u6d41\u7a0b\u62cd\u7167\u5b58\u6863<\/div>\n      <\/div>\n      <div class=\"llk-item\" data-color=\"#e74c3c\" data-target=\"p1\">\n        <span class=\"llk-label\">\u745e\u7f8e\u51b7\u51dd\u7089\u53cc\u4e00\u7ea7\u80fd\u6548<\/span>\n        <div class=\"llk-desc-box\">\u745e\u7f8e\u8fdb\u53e3\u5168\u9884\u6df7\u51b7\u51dd\u7089LL1GBQ24-CBX1-30\u91c7\u6696\u4e00\u7ea7\u80fd\u6548\uff0c\u914d\u96f6\u51b7\u6c34\u70ed\u6c34\u5668JSQ32-GTE11\uff0816\u5347\uff09\u70ed\u6c34\u4e00\u7ea7\u80fd\u6548<\/div>\n      <\/div>\n      <div class=\"llk-item\" data-color=\"#3498db\" data-target=\"p2\">\n        <span class=\"llk-label\">\u96f6\u51b7\u6c34+\u5faa\u73af\u6cf5\u73b0\u573a\u53d8\u66f4<\/span>\n        <div class=\"llk-desc-box\">\u8fdb\u573a\u5b9a\u4f4d\u65f6\u53d1\u73b0\u71c3\u6c14\u4e0a\u4e0d\u4e86\u4e8c\u697c\uff0c\u5f53\u573a\u53d8\u66f4\u4e3a\uff1a\u51b7\u51dd\u7089\u4e0b\u52a0\u88c5\u5faa\u73af\u6cf5+16\u5347\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\uff0c\u5373\u5f00\u5373\u70ed\u4e0d\u6d6a\u8d39\u51b7\u6c34<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n  <div class=\"llk-finish-tip\">\ud83c\udf89 \u5168\u90e8\u5339\u914d\u5b8c\u6210\uff01\u672c\u5957\u65b9\u6848\u5b8c\u6574\u8986\u76d6\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u4e1a\u4e3b\u6838\u5fc3\u5c45\u4f4f\u75db\u70b9<\/div>\n<\/div>\n\n<!-- ============================================================ -->\n<!-- S2 \u00b7 \u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad\u5206\u6790 -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s2\">\n  <div class=\"step-head\"><span class=\"step-num\">S2<\/span><span class=\"step-label\">\u9700\u6c42\u75db\u70b9\u4e0e\u8bca\u65ad\u5206\u6790<\/span><\/div>\n\n  <div class=\"diag-title\">\u2460 \u5ba2\u6237\u539f\u59cb\u9700\u6c42<\/div>\n  <table class=\"diag-table\">\n    <tbody><tr><th style=\"width:32%\">\u5ba2\u6237\u8bc9\u6c42<\/th><th>\u8bca\u65ad\u4e0e\u89e3\u51b3\u65b9\u6848<\/th><\/tr>\n    <tr><td class=\"claim\">\u4e24\u5c42\u8dc3\u5c42\u5168\u5c4b\u4e2d\u592e\u7a7a\u8c03<\/td><td>\u65e5\u7acbVAM mini II\u4e24\u53f0\u5916\u673a\u5206\u5c42\u914d\u7f6e\uff08\u6bcf\u5c421\u53f0\uff09\uff1a<strong>\u4e00\u5c42\u5916\u673a RAS-140FSVN7Q\u00d71<\/strong>\uff0c\u5e26 RPIZ-71FSVNAQD\/PC\u00d71\uff08\u5ba2\u9910\u5385\uff09+ RPIZ-56FSVNAQD\/PC\u00d71\uff08\u5ba2\u9910\u5385\uff09+ RPIZ-25FSVNAQD\/PC\u00d71\uff08\u5367\u5ba4\uff09\uff1b<strong>\u4e8c\u5c42\u5916\u673a RAS-140FSVN7Q\u00d71<\/strong>\uff0c\u5e26 RPIZ-56FSVNAQD\/PC\u00d71\uff08\u4e3b\u5367\uff09+ RPIZ-28FSVNAQD\/PC\u00d71\uff08\u6b21\u5367\uff09+ RPIZ-56FSVNAQD\/PC\u00d71\uff08\u6b21\u5367\uff09\uff0c\u51712\u62d66<\/td><\/tr>\n    <tr><td class=\"claim\">\u8282\u80fd\u6027\u6392\u9996\u4f4d<\/td><td>\u745e\u7f8e\u8fdb\u53e3\u5168\u9884\u6df7\u51b7\u51dd\u7089LL1GBQ24-CBX1-30\uff08\u91c7\u6696\u4e00\u7ea7\u80fd\u6548\uff09\uff0b\u96f6\u51b7\u6c34\u70ed\u6c34\u5668JSQ32-GTE11\uff0816\u5347\uff0c\u70ed\u6c34\u4e00\u7ea7\u80fd\u6548\uff09\uff0c\u91c7\u6696\u4e0e\u70ed\u6c34\u53cc\u4e00\u7ea7\u80fd\u6548\uff0c\u957f\u671f\u4f7f\u7528\u6210\u672c\u66f4\u4f4e<\/td><\/tr>\n    <tr><td class=\"claim\">\u751f\u6d3b\u70ed\u6c34\u9700\u6c42\u9ad8<\/td><td>\u539f\u8ba1\u5212\u4e8c\u697c\u5355\u72ec\u88c5\u70ed\u6c34\u5668\uff0c\u8fdb\u573a\u5b9a\u4f4d\u65f6\u53d1\u73b0\u71c3\u6c14\u7ba1\u9053\u65e0\u6cd5\u6539\u5230\u4e8c\u697c\uff0c<strong>\u73b0\u573a\u53d8\u66f4<\/strong>\u4e3a\uff1a\u745e\u7f8e\u51b7\u51dd\u7089\u4e0b\u52a0\u88c5\u5faa\u73af\u6cf5\uff0b16\u5347\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\uff0c\u4e24\u5c42\u5373\u5f00\u5373\u70ed\u3001\u4e0d\u6d6a\u8d39\u51b7\u6c34<\/td><\/tr>\n    <tr><td class=\"claim\">\u5206\u5c42\u5206\u533a\u63a7\u5236<\/td><td>\u4e00\u697c\u5916\u673a\u5e26\u516c\u533a\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c\u52a8\u533a\u9759\u533a\u5206\u5f00\u3001\u697c\u4e0a\u697c\u4e0b\u72ec\u7acb\u7cbe\u51c6\u63a7\u6e29\uff0c\u6309\u9700\u8fd0\u884c\u66f4\u8282\u80fd<\/td><\/tr>\n    <tr><td class=\"claim\">\u51ac\u5b63\u5730\u6696\u91c7\u6696<\/td><td>159.5\u33a1\u6c34\u5730\u669610\u56de\u8def\uff08\u6bcf\u5c425\u8def\u5206\u96c6\u6c34\u5668\uff09\uff0cDe20\u76d8\u7ba1\u6807\u51c6\u95f4\u8ddd\u5e03\u7f6e\uff0c\u8f90\u5c04\u4f9b\u6696\u811a\u611f\u8212\u9002\u3001\u6e29\u5ea6\u5747\u5300<\/td><\/tr>\n  <\/tbody><\/table>\n\n  <div class=\"diag-title\">\u2461 \u9690\u85cf\u9700\u6c42\uff08\u4e24\u5c42\u8dc3\u5c42\u4e13\u5c5e\uff09<\/div>\n  <ul class=\"diag-list\">\n    <li><strong>\u71c3\u6c14\u4e0a\u4e0d\u4e86\u4e8c\u697c\uff1a<\/strong>\u539f\u8ba1\u5212\u4e8c\u697c\u5355\u72ec\u88c5\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u8fdb\u573a\u5b9a\u4f4d\u53d1\u73b0\u71c3\u6c14\u7ba1\u9053\u65e0\u6cd5\u6539\u5230\u697c\u4e0a\uff0c\u5f53\u573a\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5\u65b9\u6848\uff0c\u53d8\u66f4\u516c\u5f00\u900f\u660e\u3001\u6309\u5408\u540c\u6267\u884c\u3002<\/li>\n    <li><strong>\u51b7\u51dd\u7089\u8981\u9009\u5bf9\uff1a<\/strong>\u5168\u9884\u6df7\u4e0e\u51b7\u51dd\u7089\u6784\u9020\u8bb2\u900f\u2014\u2014\u71c3\u70e7\u66f4\u5145\u5206\u3001\u6392\u70df\u6e29\u5ea6\u66f4\u4f4e\uff0c\u4e00\u7ea7\u80fd\u6548\u843d\u5230\u957f\u671f\u71c3\u6c14\u8d39\u4e0a\u624d\u662f\u771f\u8282\u80fd\uff0c\u4e0d\u4e3a\u6982\u5ff5\u591a\u82b1\u94b1\u3002<\/li>\n    <li><strong>\u5206\u533a\u8981\u7cbe\u51c6\uff1a<\/strong>\u4e00\u53f0\u5927\u5916\u673a\u8de8\u5c42\u5e26\u4e24\u5c42\uff0c\u5206\u533a\u7c97\u3001\u80fd\u8017\u9ad8\uff1b\u53cc\u5916\u673a\u5206\u5c42\uff0b\u52a8\u533a\u9759\u533a\u5206\u5f00\uff0c\u5e38\u7528\u7a7a\u95f4\u4f18\u5148\u3001\u95f2\u7f6e\u7a7a\u95f4\u8282\u80fd\u3002<\/li>\n    <li><strong>\u9690\u853d\u5de5\u7a0b\u8981\u7559\u8bc1\uff1a<\/strong>\u540a\u9876\u5c01\u677f\u540e\u710a\u63a5\u3001\u4fdd\u538b\u65e0\u6cd5\u590d\u67e5\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\uff0b\u7cfb\u7edf\u4fdd\u538b\uff0b\u6c34\u5370\u76f8\u673a\u5168\u6d41\u7a0b\u62cd\u7167\u5b58\u6863\uff0c\u5de5\u827a\u770b\u5f97\u89c1\u3002<\/li>\n    <li><strong>\u957f\u671f\u8d26\u8981\u7b97\u6e05\uff1a<\/strong>\u7a7a\u8c03\u7efc\u5408\u80fd\u65485.8\u3001\u91c7\u6696\u70ed\u6c34\u53cc\u4e00\u7ea7\u80fd\u6548\u2014\u2014\u521d\u88c5\u6210\u672c\u4e4b\u5916\uff0c\u66f4\u770b\u5341\u5e74\u7684\u4f7f\u7528\u6210\u672c\u3002<\/li>\n  <\/ul>\n\n  <div class=\"diag-title\">\u2462 \u7cfb\u7edf\u56db\u8981\u7d20\u5339\u914d<\/div>\n  <div class=\"content-card\">\n    <table class=\"info-table\">\n      <tbody><tr><th>\u8981\u7d20<\/th><th>\u914d\u7f6e<\/th><th>\u8bf4\u660e<\/th><\/tr>\n      <tr><td>\u2744\ufe0f \u70ed\u6e90-\u7a7a\u8c03<\/td><td>\u65e5\u7acb RAS-140FSVN7Q \u00d7 2\u53f0\uff08\u4e00\u5c42\/\u4e8c\u5c42\u54041\uff09<\/td><td>\u989d\u5b9a\u5236\u51b714.0kW\/\u5236\u70ed16.0kW\uff0c\u53d8\u9891\u53cc\u8f6c\u5b50\u538b\u7f29\u673a\uff0c\u7efc\u5408\u80fd\u65485.8<\/td><\/tr>\n      <tr><td>\ud83d\udd25 \u70ed\u6e90-\u5730\u6696<\/td><td>\u745e\u7f8e LL1GBQ24-CBX1-30 \u5168\u9884\u6df7\u51b7\u51dd\u7089 \u00d7 1\u53f0<\/td><td>\u91c7\u6696\u4e00\u7ea7\u80fd\u6548\uff0c\u4e3a159.5\u33a1\u5730\u669610\u56de\u8def\u4f9b\u70ed\u6e90\uff0c\u6c34\u7535\u71c3\u63a5\u53e3\u7531\u7532\u65b9\u9884\u7559<\/td><\/tr>\n      <tr><td>\ud83d\udebf \u70ed\u6e90-\u70ed\u6c34<\/td><td>\u745e\u7f8e JSQ32-GTE11 \u96f6\u51b7\u6c34\u70ed\u6c34\u5668\uff0816\u5347\uff09\u00d7 1\u53f0 + \u5faa\u73af\u6cf5<\/td><td>\u70ed\u6c34\u4e00\u7ea7\u80fd\u6548\uff0c\u5faa\u73af\u6cf5\u5373\u5f00\u5373\u70ed\uff1b\u8fdb\u573a\u5b9a\u4f4d\u65f6\u56e0\u71c3\u6c14\u65e0\u6cd5\u4e0a\u4e8c\u697c\uff0c\u7531\u539f\"\u4e8c\u697c\u5355\u88c5\u70ed\u6c34\u5668\"\u73b0\u573a\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5<\/td><\/tr>\n      <tr><td>\ud83d\udd29 \u8f93\u914d<\/td><td>\u9f99\u715c\u7d2b\u94dc\u7ba1+\u5206\u6b67\u7ba1\uff08\u7a7a\u8c03\uff09\/ De20\u5730\u6696\u76d8\u7ba1 \/ \u70ed\u6c34\u5faa\u73af\u7ba1<\/td><td>R410A\u65b0\u51b7\u5a92\uff1b\u5730\u6696\u6bcf\u5c425\u8def\u5206\u96c6\u6c34\u5668\u96c6\u4e2d\u5206\u914d\uff1b\u70ed\u6c34\u5faa\u73af\u7ba1\u8def\u968f\u540a\u9876\u6577\u8bbe<\/td><\/tr>\n      <tr><td>\ud83c\udf00 \u672b\u7aef-\u7a7a\u8c03<\/td><td>RPIZ\u76f4\u6d41\u53d8\u9891\u5185\u673a \u00d7 6\u53f0<\/td><td>\u4e00\u5c42\uff1a71(\u5ba2\u9910\u5385)+56(\u5ba2\u9910\u5385)+25(\u5367\u5ba4)\uff1b\u4e8c\u5c42\uff1a56(\u4e3b\u5367)+28(\u6b21\u5367)+56(\u6b21\u5367)<\/td><\/tr>\n      <tr><td>\ud83c\udf21\ufe0f \u672b\u7aef-\u5730\u6696<\/td><td>\u5730\u6696\u76d8\u7ba1 159.5\u33a1 \/ 10\u56de\u8def<\/td><td>\u5ba2\u9910\u53854\u56de\u8def+\u4e3b\u53672\u56de\u8def+\u6b21\u53673\u56de\u8def+\u5367\u5ba41\u56de\u8def<\/td><\/tr>\n      <tr><td>\ud83c\udf9b\ufe0f \u63a7\u5236<\/td><td>WIFI\u7ebf\u63a7\u5668 PC-P1HVQA \u00d7 6 + \u5206\u5c42\u5206\u533a\u63a7\u5236<\/td><td>\u697c\u4e0a\u697c\u4e0b\u5206\u5c42\u63a7\u5236\uff1a\u4e00\u697c\u5916\u673a\u5e26\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff1b\u5404\u623f\u95f4\u72ec\u7acb\u5f00\u5173\u8c03\u6e29\uff0c\u652f\u6301\u8fdc\u7a0b\u63a7\u5236<\/td><\/tr>\n    <\/tbody><\/table>\n  <\/div>\n\n  <div class=\"diag-title\">\u2463 \u51b7\/\u70ed\u8d1f\u8377\u8bbe\u8ba1\u4f9d\u636e<\/div>\n  <div class=\"content-card\">\n    <table class=\"info-table\">\n      <tbody><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u51b7\u8d1f\u8377\u6307\u6807<\/th><th>\u9700\u6c42\u51b7\u91cf<\/th><th>\u914d\u7f6e\u5185\u673a<\/th><\/tr>\n      <tr><td rowspan=\"3\">\u4e00\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>65.5\u33a1<\/td><td>150W\/\u33a1<\/td><td>9825W<\/td><td>RPIZ-71FSVNAQD\/PC<\/td><\/tr>\n      <tr><td>\u5ba2\u9910\u5385\uff08\u8f85\u52a9\uff09<\/td><td>\u2014<\/td><td>\u2014<\/td><td>5600W<\/td><td>RPIZ-56FSVNAQD\/PC<\/td><\/tr>\n      <tr><td>\u5367\u5ba4<\/td><td>12.3\u33a1<\/td><td>150W\/\u33a1<\/td><td>1845W<\/td><td>RPIZ-25FSVNAQD\/PC<\/td><\/tr>\n      <tr><td rowspan=\"3\">\u4e8c\u5c42<\/td><td>\u4e3b\u5367<\/td><td>27\u33a1<\/td><td>150W\/\u33a1<\/td><td>4050W<\/td><td>RPIZ-56FSVNAQD\/PC<\/td><\/tr>\n      <tr><td>\u6b21\u5367<\/td><td>14.7\u33a1<\/td><td>150W\/\u33a1<\/td><td>2205W<\/td><td>RPIZ-28FSVNAQD\/PC<\/td><\/tr>\n      <tr><td>\u6b21\u5367<\/td><td>30\u33a1<\/td><td>150W\/\u33a1<\/td><td>4500W<\/td><td>RPIZ-56FSVNAQD\/PC<\/td><\/tr>\n    <\/tbody><\/table>\n    <div class=\"disclaimer\" style=\"margin-top:10px\">\u26a0\ufe0f \u5b9e\u9645\u51b7\u6307\u6807\uff1a\u4e00\u5c42194W\/\u33a1\u3001\u4e8c\u5c42\u4e3b\u5367207W\/\u33a1\uff0c\u5747\u9ad8\u4e8e\u9700\u6c42\u503c\uff1b\u5730\u6696\u70ed\u8d1f\u8377\u6309100W\/\u33a1\u8bbe\u8ba1\u3002\u8bbe\u8ba1\u6e29\u5ea6\uff1a\u590f\u5b6324~26\u2103\u3001\u51ac\u5b6318~22\u2103\u3002<\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S3 \u00b7 \u89e3\u51b3\u65b9\u6848\u548c\u6210\u672c\u5206\u6790 -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s3\">\n  <div class=\"step-head\"><span class=\"step-num\">S3<\/span><span class=\"step-label\">\u89e3\u51b3\u65b9\u6848\u548c\u6210\u672c\u5206\u6790<\/span><\/div>\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s3-tab1')\">\u65b9\u6848\u5bf9\u6bd4<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s3-tab2')\">\u53cc\u7cfb\u7edf\u914d\u7f6e<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s3-tab3')\">\u914d\u7f6e\u56fe\u96c6<\/div>\n  <\/div>\n\n  <div id=\"s3-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83d\udd0d \u5173\u952e\u7ed3\u8bba\uff1a\u8dc3\u5c42\u4f4f\u5b85\u51b7\u6696\u65b9\u6848\u4e2d\uff0c\"\u6c1f\u673a\u4e2d\u592e\u7a7a\u8c03+\u72ec\u7acb\u51b7\u51dd\u7089\u5730\u6696\"\u5404\u53f8\u5176\u804c\uff0c\u6bd4\u5355\u4e00\u7cfb\u7edf\u517c\u987e\u51b7\u6696\u5728\u8212\u9002\u5ea6\u4e0e\u80fd\u8017\u4e0a\u66f4\u5408\u7406\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcca \u8dc3\u5c42\u51b7\u6696\u65b9\u6848\u5bf9\u6bd4<\/div>\n      <table class=\"compare-table\">\n        <tbody><tr><th class=\"col-header-a\">\u65b9\u6848<\/th><th class=\"col-header-b\">\u6c1f\u673a+\u9505\u7089\u5730\u6696\uff08\u2705 \u672c\u6848\u9009\u5b9a\uff09<\/th><th class=\"col-header-a\">\u4e24\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\uff09<\/th><\/tr>\n        <tr><td>\u590f\u5b63\u5236\u51b7<\/td><td class=\"col-recommend\">\u6c1f\u673a\u76f4\u63a5\u84b8\u53d1\u5236\u51b7\uff0c\u54cd\u5e94\u5feb\u3001\u6548\u7387\u9ad8<\/td><td>\u6c34\u673a\u4e8c\u6b21\u6362\u70ed\uff0c\u5236\u51b7\u901f\u5ea6\u7565\u6162<\/td><\/tr>\n        <tr><td>\u51ac\u5b63\u91c7\u6696<\/td><td class=\"col-recommend\">\u5730\u6696\u8f90\u5c04\u4f9b\u6696\uff0c\u811a\u611f\u8212\u9002\u6e29\u5ea6\u5747\u5300<\/td><td>\u5730\u6696\u4f9b\u6696\uff0c\u5f62\u5f0f\u76f8\u540c<\/td><\/tr>\n        <tr><td>\u7cfb\u7edf\u72ec\u7acb\u6027<\/td><td class=\"col-recommend\">\u7a7a\u8c03\u5730\u6696\u5404\u81ea\u72ec\u7acb\uff0c\u6545\u969c\u4e92\u4e0d\u5f71\u54cd<\/td><td>\u4e00\u5957\u4e3b\u673a\uff0c\u8026\u5408\u5ea6\u8f83\u9ad8<\/td><\/tr>\n        <tr><td>\u5206\u5c42\u9002\u914d<\/td><td class=\"col-recommend\">\u4e24\u53f0\u5916\u673a\u6bcf\u5c421\u53f0\uff0c\u7ba1\u8def\u77ed\u3001\u8870\u51cf\u5c0f<\/td><td>\u4e00\u53f0\u4e3b\u673a\u8de8\u5c42\uff0c\u7ba1\u8def\u8f83\u957f<\/td><\/tr>\n        <tr><td>\u7ef4\u62a4<\/td><td class=\"col-recommend\">\u6c1f\u673a\u514d\u7ef4\u62a4\u7a0b\u5ea6\u9ad8\uff0c\u5730\u6696\u7cfb\u7edf\u7b80\u5355<\/td><td>\u6c34\u7cfb\u7edf\u9700\u5b9a\u671f\u7ef4\u62a4\u9632\u8150\u8680<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s3-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\u2705 \u914d\u7f6e\u5b9a\u7a3f\uff1a\u7a7a\u8c036\u53f0\u5185\u673a+\u53cc\u5916\u673a\u5206\u5c42\uff0c\u5730\u6696159.5\u33a1\/10\u56de\u8def\uff0c\u5747\u5df2\u6309\u5408\u540c\u6e05\u5355\u5b9a\u7a3f\u5b89\u88c5\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\u2744\ufe0f \u65e5\u7acb VAM mini II \u7a7a\u8c03\u914d\u7f6e\uff082\u62d66\uff09<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u53f0\u6570<\/th><th>\u5b9e\u9645\u51b7\u6307\u6807<\/th><\/tr>\n        <tr><td rowspan=\"3\">\u4e00\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-71FSVNAQD\/PC<\/td><td>1<\/td><td>194W\/\u33a1<\/td><\/tr>\n        <tr><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-56FSVNAQD\/PC<\/td><td>1<\/td><td>\u2014<\/td><\/tr>\n        <tr><td>\u5367\u5ba4<\/td><td>RPIZ-25FSVNAQD\/PC<\/td><td>1<\/td><td>203W\/\u33a1<\/td><\/tr>\n        <tr><td rowspan=\"3\">\u4e8c\u5c42<\/td><td>\u4e3b\u5367<\/td><td>RPIZ-56FSVNAQD\/PC<\/td><td>1<\/td><td>207W\/\u33a1<\/td><\/tr>\n        <tr><td>\u6b21\u5367<\/td><td>RPIZ-28FSVNAQD\/PC<\/td><td>1<\/td><td>190W\/\u33a1<\/td><\/tr>\n        <tr><td>\u6b21\u5367<\/td><td>RPIZ-56FSVNAQD\/PC<\/td><td>1<\/td><td>187W\/\u33a1<\/td><\/tr>\n        <tr><td colspan=\"2\">\u5916\u673a\uff08\u6bcf\u5c421\u53f0\uff09<\/td><td>RAS-140FSVN7Q<\/td><td>2<\/td><td>\u8fde\u63a5\u7387108.6%\/100.0%<\/td><\/tr>\n        <tr><td colspan=\"2\">\u7ebf\u63a7\u5668<\/td><td>WIFI\u7ebf\u63a7 PC-P1HVQA<\/td><td>6<\/td><td>\u4e00\u4e00\u5bf9\u5e94<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udd25 \u6c34\u5730\u6696\u914d\u7f6e\uff08159.5\u33a1 \/ 10\u56de\u8def\uff09<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u697c\u5c42<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u56de\u8def\u6570<\/th><th>\u76d8\u7ba1\u89c4\u683c<\/th><\/tr>\n        <tr><td rowspan=\"2\">\u4e00\u5c42<\/td><td>\u5ba2\u9910\u5385<\/td><td>65.5\u33a1<\/td><td>4<\/td><td rowspan=\"5\">De20\u76d8\u7ba1<br>\u6807\u51c6\u95f4\u8ddd200mm<br>\u70ed\u8d1f\u8377100W\/\u33a1<\/td><\/tr>\n        <tr><td>\u5367\u5ba4<\/td><td>13\u33a1<\/td><td>1<\/td><\/tr>\n        <tr><td rowspan=\"3\">\u4e8c\u5c42<\/td><td>\u4e3b\u5367<\/td><td>27\u33a1<\/td><td>2<\/td><\/tr>\n        <tr><td>\u6b21\u5367<\/td><td>24\u33a1<\/td><td>1<\/td><\/tr>\n        <tr><td>\u6b21\u5367<\/td><td>30\u33a1<\/td><td>2<\/td><\/tr>\n        <tr><td colspan=\"2\">\u5206\u96c6\u6c34\u5668<\/td><td>10\u8def\uff08\u6bcf\u5c425\u8def\uff09<\/td><td>\u2014<\/td><td>\u70ed\u6e90\uff1a\u745e\u7f8eLL1GBQ24-CBX1-30\u51b7\u51dd\u7089\u00d71\u53f0<\/td><\/tr>\n      <\/tbody><\/table>\n      <div class=\"disclaimer\" style=\"margin-top:10px\">\u26a0\ufe0f \u9020\u4ef7\u8bf4\u660e\uff1a\u5177\u4f53\u9020\u4ef7\u56e0\u65f6\u6548\u6027\u56e0\u7d20\u672a\u516c\u5f00\uff0c\u8bf7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\u3002<\/div>\n    <\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udebf \u751f\u6d3b\u70ed\u6c34\u914d\u7f6e\uff08\u96f6\u51b7\u6c34 \u00b7 \u4e00\u7ea7\u80fd\u6548\uff09<\/div>\n      <table class=\"info-table\">\n        <tbody><tr><th>\u8bbe\u5907<\/th><th>\u578b\u53f7<\/th><th>\u8bf4\u660e<\/th><\/tr>\n        <tr><td>\u96f6\u51b7\u6c34\u71c3\u6c14\u70ed\u6c34\u5668<\/td><td>\u745e\u7f8e JSQ32-GTE11\uff0816\u5347\uff09<\/td><td>\u70ed\u6c34\u4e00\u7ea7\u80fd\u6548\uff0c\u6ee1\u8db3\u5927\u5bb6\u5ead\u9ad8\u70ed\u6c34\u9700\u6c42<\/td><\/tr>\n        <tr><td>\u70ed\u6c34\u5faa\u73af\u6cf5<\/td><td>\u968f\u51b7\u51dd\u7089\u5c31\u8fd1\u5b89\u88c5<\/td><td>\u8fdb\u573a\u5b9a\u4f4d\u65f6\u56e0\u71c3\u6c14\u65e0\u6cd5\u6539\u5230\u4e8c\u697c\uff0c\u7531\u539f\"\u4e8c\u697c\u5355\u88c5\u70ed\u6c34\u5668\"\u73b0\u573a\u53d8\u66f4\uff1a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5\uff0c\u5168\u5c4b\u5373\u5f00\u5373\u70ed<\/td><\/tr>\n        <tr><td>\u91c7\u6696\u70ed\u6e90<\/td><td>\u745e\u7f8e LL1GBQ24-CBX1-30 \u5168\u9884\u6df7\u51b7\u51dd\u7089 \u00d7 1\u53f0<\/td><td>\u91c7\u6696\u4e00\u7ea7\u80fd\u6548\uff0c\u517c\u987e\u5730\u6696\u4f9b\u70ed\u4e0e\u7cfb\u7edf\u8282\u80fd<\/td><\/tr>\n      <\/tbody><\/table>\n      <div class=\"disclaimer\" style=\"margin-top:10px\">\u2705 \u73b0\u573a\u53d8\u66f4\u8bf4\u660e\uff1a\u539f\u65b9\u6848\u4e8c\u697c\u5355\u72ec\u5b89\u88c5\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u8fdb\u573a\u5b9a\u4f4d\u65f6\u53d1\u73b0\u71c3\u6c14\u7ba1\u9053\u65e0\u6cd5\u4e0a\u4e8c\u697c\uff0c\u7ecf\u4e0e\u5218\u8001\u5e08\u73b0\u573a\u786e\u8ba4\uff0c\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u88c5\u5faa\u73af\u6cf5+\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\u65b9\u6848\u2014\u2014\u53d8\u66f4\u516c\u5f00\u900f\u660e\uff0c\u6309\u5408\u540c\u7ea6\u5b9a\u6267\u884c\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s3-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83c\udfaf \u843d\u5730\u8981\u70b9\uff1a\u4ee5\u4e0b\u4e3a\u5730\u6696\/\u7a7a\u8c03\u8bbe\u8ba1\u65b9\u6848\u56fe\u4e0e\u914d\u7f6e\u8868\uff0c\u4fbf\u4e8e\u76f4\u89c2\u6838\u5bf9\u9009\u578b\u4e0e\u7ba1\u8def\u5e03\u7f6e\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u51fa\u56fe\u4e3a\u51c6\u3002<\/div>\n    <div class=\"photo-phase\">\n      <div class=\"phase-label\">\ud83d\udd25 \u5730\u6696\u8bbe\u8ba1\u56fe \/ \u914d\u7f6e\uff08\u51713\u5f20\uff09<\/div>\n      <div class=\"photo-grid\">\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt1l.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u4e00\u5c42\u5730\u6696\u76d8\u7ba1\u5e73\u9762\u56fe\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u4e00\u5c42\u5730\u6696\u76d8\u7ba1\u5e73\u9762\u56fe<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt2l.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u4e8c\u5c42\u5730\u6696\u76d8\u7ba1\u5e73\u9762\u56fe\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u4e8c\u5c42\u5730\u6696\u76d8\u7ba1\u5e73\u9762\u56fe<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpzt.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u5730\u6696\u65b9\u6848\u914d\u7f6e\u8868\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u5730\u6696\u65b9\u6848\u914d\u7f6e\u8868<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n    <div class=\"photo-phase\">\n      <div class=\"phase-label\">\u2744\ufe0f \u7a7a\u8c03\u8bbe\u8ba1\u56fe \/ \u914d\u7f6e\uff08\u51713\u5f20\uff09<\/div>\n      <div class=\"photo-grid\">\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-ktpmt1l.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u4e00\u5c42\u7a7a\u8c03\u5e73\u9762\u56fe\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u4e00\u5c42\u7a7a\u8c03\u5e73\u9762\u56fe<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-ktpmt2l.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u4e8c\u5c42\u7a7a\u8c03\u5e73\u9762\u56fe\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u4e8c\u5c42\u7a7a\u8c03\u5e73\u9762\u56fe<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-ktpzt.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u914d\u7f6e\u8868\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u914d\u7f6e\u8868<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n    <div class=\"content-card\" style=\"border:1px dashed var(--gold);background:#fbf8f1\">\n      <div class=\"card-title\">\ud83d\udccc \u56fe\u7247\u8bf4\u660e<\/div>\n      <div class=\"card-desc\">\u4e0a\u56fe\u4e3a\u5218\u8001\u5e08\u5bb6<strong>\u5730\u6696\u4e0e\u7a7a\u8c03\u7684\u8bbe\u8ba1\u5b9a\u7a3f<\/strong>\uff1a\u5730\u6696\u4e24\u5c42\u54045\u8def\u5206\u96c6\u6c34\u5668\u517110\u56de\u8def\u3001\u7ba1\u957f31~79\u7c73\u4e0d\u7b49\uff1b\u7a7a\u8c03\u4e24\u53f0\u5916\u673a\u5206\u5c42\u5e03\u7f6e\uff0c\u5185\u673a\u6cbf\u540a\u9876\u6697\u85cf\u3002\u578b\u53f7\u5747\u5df2\u5b9a\u7a3f\uff08\u8be6\u89c1\u4e0a\u65b9\"\u53cc\u7cfb\u7edf\u914d\u7f6e\"\uff09\u3002<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S4 \u00b7 \u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s4\">\n  <div class=\"step-head\"><span class=\"step-num\">S4<\/span><span class=\"step-label\">\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u670d\u52a1\u4fdd\u969c<\/span><\/div>\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s4-tab1')\">\u516d\u6b65\u7cbe\u5de5<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab2')\">\u65bd\u5de5\u7167\u7247<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab3')\">\u7cbe\u5de5\u5bf9\u6bd4<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab4')\">\u8d44\u8d28\u4e0e\u95e8\u5e97<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s4-tab5')\">\u552e\u540e\u4fdd\u969c<\/div>\n  <\/div>\n\n  <div id=\"s4-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83d\udccc \u6838\u5fc3\u8981\u70b9\uff1a\u4e00\u671f\u9690\u853d\u5de5\u7a0b\u516d\u6b65\u7cbe\u5de5\u2014\u2014\u52d8\u6d4b\u5b9a\u4f4d\u2192\u5185\u673a\u540a\u88c5\u2192\u6c2e\u4fdd\u710a\u63a5\u2192\u7ba1\u9053\u5b89\u88c5\u2192\u7cfb\u7edf\u4fdd\u538b\u2192\u8c03\u8bd5\u9a8c\u6536\uff0c2026\u5e7410\u670814\u65e5\u8fdb\u573a\u3002<\/div>\n    <div class=\"promise-grid\">\n      <div class=\"promise-card\"><div class=\"icon\">\ud83d\udd0d<\/div><div class=\"title\">\u2460 \u52d8\u6d4b\u5b9a\u4f4d<\/div><div class=\"desc\">\u4e24\u5c42\u8dc3\u5c42\u5185\u5916\u673a\u5b9a\u4f4d\uff0c\u7ba1\u8def\u8d70\u5411\u89c4\u5212<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83c\udfd7\ufe0f<\/div><div class=\"title\">\u2461 \u5185\u673a\u540a\u88c5<\/div><div class=\"desc\">\u6c34\u5e73\u540a\u88c5\uff0c\u53cc\u87ba\u6bcd+\u53cc\u51cf\u9707\u57ab\u56fa\u5b9a<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83d\udd25<\/div><div class=\"title\">\u2462 \u6c2e\u4fdd\u710a\u63a5<\/div><div class=\"desc\">\u9f99\u715c\u7d2b\u94dc\u7ba1\u710a\u63a5\u5145\u6c2e\u4fdd\u62a4\uff0c\u9632\u6c27\u5316\u76ae<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83e\udde9<\/div><div class=\"title\">\u2463 \u7ba1\u9053\u5b89\u88c5<\/div><div class=\"desc\">\u51b7\u5a92\u7ba1\/\u51b7\u51dd\u6c34\u7ba1\/\u4fdd\u6e29\u5206\u5c42\u6577\u8bbe<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\ud83e\uddea<\/div><div class=\"title\">\u2464 \u7cfb\u7edf\u4fdd\u538b<\/div><div class=\"desc\">R410A\u7cfb\u7edf\u4fdd\u538b\u68c0\u6f0f\uff0c\u538b\u529b\u8868\u7559\u8bc1<\/div><\/div>\n      <div class=\"promise-card\"><div class=\"icon\">\u2705<\/div><div class=\"title\">\u2465 \u8c03\u8bd5\u9a8c\u6536<\/div><div class=\"desc\">WIFI\u7ebf\u63a7\u63a5\u7ebf\u8c03\u8bd5\uff0c\u98ce\u53e3\u6210\u54c1\u4fdd\u62a4<\/div><\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udcf7 \u65bd\u5de5\u5b9e\u5f55\uff1a2026\u5e7410\u670814\u65e5-16\u65e5\u73b0\u573a\u6253\u5361\u5f71\u50cf\uff08\u6c34\u5370\u76f8\u673a\uff09\uff0c\u9690\u853d\u5de5\u7a0b\u5168\u8fc7\u7a0b\u7559\u8bc1\u3002<\/div>\n    <div class=\"photo-phase\">\n      <div class=\"phase-label\">\ud83d\udd25 \u4e00\u671f\u9690\u853d\u5de5\u7a0b\u65bd\u5de5\u5b9e\u5f55\uff08\u51718\u5f20\uff09<\/div>\n      <div class=\"photo-grid\">\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-njtglj.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u5185\u673a\u94dc\u7ba1\u8fde\u63a5\u710a\u63a5\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u5185\u673a\u94dc\u7ba1\u8fde\u63a5\u710a\u63a5\uff0810-14\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-xtby2.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u6c2e\u6c14\u4fdd\u62a4\u710a\u8bbe\u5907\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u6c2e\u6c14\u4fdd\u62a4\u710a\u8bbe\u5907\uff0810-14\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-njwgt.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u5ba4\u5185\u673a\u540a\u88c5\u5c31\u4f4d\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u5ba4\u5185\u673a\u540a\u88c5\u5c31\u4f4d\uff0810-16\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-njwgt2.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u5ba4\u5185\u673a\u540a\u88c5\u5c31\u4f4d2\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u5ba4\u5185\u673a\u540a\u88c5\u5c31\u4f4d\u2461\uff0810-16\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-gdazt.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u51b7\u5a92\u7ba1\u4e0e\u51b7\u51dd\u6c34\u7ba1\u5b89\u88c5\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u51b7\u5a92\u7ba1\u4e0e\u51b7\u51dd\u6c34\u7ba1\u5b89\u88c5\uff0810-16\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-mbazt.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08WIFI\u7ebf\u63a7\u5668\u5e95\u76d2\u9884\u57cb\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-WIFI\u7ebf\u63a7\u5668\u5e95\u76d2\u9884\u57cb\uff0810-16\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-xtby.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u7cfb\u7edf\u4fdd\u538b\u538b\u529b\u8868\u8bfb\u6570\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u7cfb\u7edf\u4fdd\u538b\u538b\u529b\u8868\u8bfb\u6570\uff0810-16\uff09<\/figcaption><\/figure>\n        <figure class=\"photo-item\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-wjaz.jpg\" alt=\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08\u5ba4\u5916\u673a\u5c31\u4f4dVAM mini II\" loading=\"lazy\"><figcaption>\u4e07\u79d1\u5929\u5e9c\u540d\u90b8-\u5218\u8001\u5e08-\u5ba4\u5916\u673a\u5c31\u4f4dVAM mini II\uff0810-16\uff09<\/figcaption><\/figure>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udca1 \u65b9\u6848\u903b\u8f91\uff1a\u9f99\u8109\u7cbe\u5de5 vs \u884c\u4e1a\u901a\u914d\u505a\u6cd5\uff0c\u94dc\u7ba1\u710a\u63a5\u3001\u5185\u673a\u56fa\u5b9a\u3001\u4fdd\u538b\u68c0\u6f0f\u5173\u952e\u5de5\u827a\u66f4\u89c4\u8303\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcca \u9f99\u8109\u7cbe\u5de5 vs \u666e\u901a\u5b89\u88c5\u5bf9\u6bd4<\/div>\n      <table class=\"compare-table\">\n        <tbody><tr><th class=\"col-header-a\">\u5de5\u827a\u9879<\/th><th class=\"col-header-b\">\u9f99\u8109\u7cbe\u5de5\uff08\u2705 \u63a8\u8350\uff09<\/th><th class=\"col-header-a\">\u666e\u901a\u5b89\u88c5<\/th><\/tr>\n        <tr><td>\u94dc\u7ba1\u710a\u63a5<\/td><td class=\"col-recommend\">\u5145\u6c2e\u4fdd\u62a4\u710a\uff0c\u7ba1\u5185\u65e0\u6c27\u5316\u76ae<\/td><td>\u76f4\u63a5\u710a\u63a5\uff0c\u6613\u4ea7\u6c27\u5316\u76ae\u5835\u7cfb\u7edf<\/td><\/tr>\n        <tr><td>\u5185\u673a\u56fa\u5b9a<\/td><td class=\"col-recommend\">\u53cc\u87ba\u6bcd+\u53cc\u51cf\u9707\u57ab\uff0c\u8fd0\u884c\u4e0d\u5171\u632f<\/td><td>\u5355\u87ba\u6bcd\u56fa\u5b9a\uff0c\u6613\u677e\u52a8\u6709\u5f02\u54cd<\/td><\/tr>\n        <tr><td>\u51b7\u51dd\u6c34<\/td><td class=\"col-recommend\">De25\u7ba1\u6807\u51c6\u5761\u5ea6+\u6392\u6c34\u8bd5\u9a8c<\/td><td>\u7ba1\u5f84\u504f\u5c0f\u5761\u5ea6\u4e0d\u8db3\uff0c\u6613\u79ef\u6c34<\/td><\/tr>\n        <tr><td>\u4fdd\u6e29<\/td><td class=\"col-recommend\">\u94dc\u7ba120mm\/\u6c34\u7ba19mm\u4f18\u83f2\u7279\u4e13\u4f9b<\/td><td>\u4fdd\u6e29\u504f\u8584\uff0c\u540a\u9876\u6613\u7ed3\u9732<\/td><\/tr>\n        <tr><td>\u4fdd\u538b\u68c0\u6f0f<\/td><td class=\"col-recommend\">R410A\u4fdd\u538b\u68c0\u6f0f\uff0c\u538b\u529b\u8868\u7559\u8bc1<\/td><td>\u5e38\u7701\u7565\uff0c\u9690\u60a3\u96be\u67e5<\/td><\/tr>\n        <tr><td>\u9690\u853d\u7559\u8bc1<\/td><td class=\"col-recommend\">\u6c34\u5370\u76f8\u673a\u5168\u6d41\u7a0b\u62cd\u7167\u5b58\u6863<\/td><td>\u65e0\u8fc7\u7a0b\u8bb0\u5f55<\/td><\/tr>\n      <\/tbody><\/table>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83c\udfc5 \u5173\u952e\u7ed3\u8bba\uff1a\u65e5\u7acb\u6388\u6743\u5b89\u88c5 + \u9f99\u8109\u6696\u901a \u00b7 2004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6 + \u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u4fdd\u969c\u5218\u8001\u5e08\u5bb6\u552e\u524d\u552e\u540e\u5168\u7a0b\u670d\u52a1\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83c\udfec \u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97 \u00b7 \u5c31\u8fd1\u670d\u52a1<\/div>\n      <div class=\"info-row\">\n        <div class=\"info-cell\"><div class=\"store-card\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\" loading=\"lazy\"><div class=\"store-name\">\ud83d\udccd \u5357\u5bcc\u68ee\u5e97<\/div><div class=\"store-addr\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<br>\u7535\u8bdd\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><\/div><\/div><\/div>\n        <div class=\"info-cell\"><div class=\"store-card\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\" loading=\"lazy\"><div class=\"store-name\">\ud83d\udccd \u5317\u5bcc\u68ee\u5e97<\/div><div class=\"store-addr\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7<br>\u7535\u8bdd\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><\/div><\/div><\/div>\n      <\/div>\n      <div class=\"disclaimer\" style=\"margin-top:10px\">\u2705 \u6b63\u89c4\u6388\u6743\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546\uff0c\u8bbe\u5907\u539f\u5382\u8d28\u4fdd\uff0c\u5b89\u88c5\u5de5\u827a\u6309\u65e5\u7acb\u7cbe\u5de5\u6807\u51c6\u6267\u884c\u3002<\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s4-tab5\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udee1\ufe0f \u8d28\u4fdd\u4e0e\u670d\u52a1\u4f53\u7cfb\uff1a\u8bbe\u5907+\u5b89\u88c5\u53cc\u8d28\u4fdd\uff0c\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\u53ef\u67e5\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udee1\ufe0f \u9f99\u8109\u8d28\u4fdd\u4e0e\u670d\u52a1\u627f\u8bfa<\/div>\n      <div class=\"card-desc\">\n        \u2460 \u8bbe\u5907\u8d28\u4fdd\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u539f\u5382\u8d28\u4fdd\uff08\u6574\u673a\u8d28\u4fdd\u671f\u5185\u4eab\u5b98\u65b9\u4fdd\u4fee\uff09\uff1b<br>\n        \u2461 \u5b89\u88c5\u8d28\u4fdd\uff1a\u9f99\u8109\u81ea\u6709\u65bd\u5de5\u56e2\u961f\u975e\u5916\u5305\uff0c\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u7559\u6863\u53ef\u8ffd\u6eaf\uff1b<br>\n        \u2462 \u54cd\u5e94\u673a\u5236\uff1a24\u5c0f\u65f6\u7d27\u6025\u670d\u52a1\u70ed\u7ebf\uff0c2004\u5e74\u8d77\u6301\u7eed\u670d\u52a1\u672c\u571f\u4e1a\u4e3b\uff1b<br>\n        \u2463 \u5de1\u68c0\u670d\u52a1\uff1a\u91c7\u6696\u5b63\u524d\u53ef\u9884\u7ea6\u4e0a\u95e8\u5de1\u68c0\u8c03\u8bd5\uff0c\u4fdd\u969c\u7cfb\u7edf\u9ad8\u6548\u8fd0\u884c\u3002\n      <\/div>\n      <div class=\"disclaimer\" style=\"margin-top:10px\">\u26a0\ufe0f \u8bf4\u660e\uff1a\u8d28\u4fdd\u7ec6\u5219\u4ee5\u5408\u540c\u7ea6\u5b9a\u4e3a\u51c6\uff0c\u8f85\u6750\u6e05\u5355\u6570\u91cf\u4ee5\u5de5\u5730\u5b9a\u4f4d\u540e\u5b9e\u9645\u5b89\u88c5\u4e3a\u51c6\u3002<\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S5 \u00b7 \u9a8c\u8bc1\u8fed\u4ee3 -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s5\">\n  <div class=\"step-head\"><span class=\"step-num\">S5<\/span><span class=\"step-label\">\u9a8c\u8bc1\u8fed\u4ee3<\/span><\/div>\n  <div class=\"section-tabs\">\n    <div class=\"section-tab active\" onclick=\"switchTab(this,'s5-tab1')\">\u6848\u4f8b\u590d\u76d8<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab2')\">\u4e13\u4e1a\u4e3b\u5f20<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab3')\">\u98ce\u9669\u544a\u77e5<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab4')\">\u4f7f\u7528\u8d34\u58eb<\/div>\n    <div class=\"section-tab\" onclick=\"switchTab(this,'s5-tab5')\">\u9ad8\u9891\u95ee\u7b54<\/div>\n  <\/div>\n\n  <div id=\"s5-tab1\" class=\"tab-panel\">\n    <div class=\"conclusion-bar\">\ud83c\udfaf \u843d\u5730\u8981\u70b9\uff1a\u4ece\u9700\u6c42\u6c9f\u901a\u2192\u65b9\u6848\u786e\u5b9a\u2192\u4e00\u671f\u8fdb\u573a\u2192\u9690\u853d\u65bd\u5de5\u2192\u4fdd\u538b\u7559\u8bc1\uff0c\u5168\u7a0b\u8303\u4e3d\u5982\u5bf9\u63a5\uff0c\u4ee5\"\u53cc\u5916\u673a\u5206\u5c42+\u6c2e\u4fdd\u710a\u63a5+\u7cfb\u7edf\u4fdd\u538b\"\u843d\u5b9a\u5218\u8001\u5e08\u5bb6\u51b7\u6696\u53cc\u7cfb\u7edf\u3002<\/div>\n    <div class=\"timeline\">\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u9700\u6c42\u6c9f\u901a<\/div><div class=\"timeline-detail\">\u8282\u80fd\u6027\u4f18\u5148+\u9ad8\u70ed\u6c34\u9700\u6c42+\u5206\u5c42\u5206\u533a\u63a7\u5236\uff0c\u51b7\u6696\u70ed\u6c34\u4e09\u7cfb\u7edf\u5b9a\u4f4d<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u65b9\u6848\u5b9a\u7a3f<\/div><div class=\"timeline-detail\">VAM mini II 2\u62d66 + \u5730\u669610\u56de\u8def + \u745e\u7f8e\u51b7\u51dd\u7089\/\u96f6\u51b7\u6c34\u70ed\u6c34\u914d\u7f6e\u786e\u8ba4<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u8fdb\u573a\u5b9a\u4f4d<\/div><div class=\"timeline-detail\">\u53d1\u73b0\u71c3\u6c14\u65e0\u6cd5\u4e0a\u4e8c\u697c\uff0c\u73b0\u573a\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5\u65b9\u6848\uff0c\u900f\u660e\u786e\u8ba4<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u9690\u853d\u65bd\u5de5<\/div><div class=\"timeline-detail\">2026-10-14 \u8fdb\u573a\uff0c\u5185\u673a\u540a\u88c5+\u6c2e\u4fdd\u710a\u63a5+\u7ba1\u9053\u6577\u8bbe\uff0c\u6c34\u5370\u7559\u8bc1<\/div><\/div>\n      <div class=\"timeline-step\"><div class=\"timeline-dot\"><\/div><div class=\"timeline-label\">\u4fdd\u538b\u5f85\u9a8c<\/div><div class=\"timeline-detail\">R410A\u7cfb\u7edf\u4fdd\u538b\u68c0\u6f0f\uff0c\u5f85\u540a\u9876\u540e\u8c03\u8bd5\u4ea4\u4ed8<\/div><\/div>\n    <\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udcac \u5ba2\u6237\u53cd\u9988<\/div>\n      <div class=\"card-desc\">\n        \u5218\u8001\u5e08\u5bf9<strong>\u5206\u5c42\u5206\u533a\u63a7\u5236\u65b9\u6848<\/strong>\u548c<strong>\u7cfb\u7edf\u8282\u80fd\u5ea6<\/strong>\u9ad8\u5ea6\u8ba4\u53ef\u2014\u2014\u81ea\u4e13\u4e1a\u6280\u672f\u6c9f\u901a\uff08\u51b7\u51dd\u7089\u5168\u9884\u6df7\u6784\u9020\u4e0e\u4e00\u7ea7\u80fd\u6548\u8bb2\u89e3\uff09\u8d77\u4fbf\u679c\u65ad\u4e0b\u5b9a\uff0c\u4fe1\u4efb\u5ea6\u975e\u5e38\u9ad8\uff1b\u8fdb\u573a\u5b9a\u4f4d\u9047\u5230\u71c3\u6c14\u65e0\u6cd5\u4e0a\u4e8c\u697c\u65f6\uff0c\u5bf9\u6211\u65b9\u4e3b\u52a8\u63d0\u51fa\u5faa\u73af\u6cf5\u66ff\u4ee3\u65b9\u6848\u3001\u5f53\u573a\u900f\u660e\u786e\u8ba4\u7684\u5904\u7406\u65b9\u5f0f\u8868\u793a\u6ee1\u610f\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab2\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udcd0 \u4e13\u4e1a\u4e3b\u5f20\uff1a\u8dc3\u5c42\u4f4f\u5b85\u51b7\u6696\u7cfb\u7edf\"\u5206\u5c42\u72ec\u7acb\"\u4f18\u4e8e\"\u4e00\u5957\u4e3b\u673a\u8de8\u5c42\"\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udca1 \u9f99\u8109\u4e13\u4e1a\u4e3b\u5f20<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u5206\u5c42\u5916\u673a\u66f4\u9760\u8c31<\/strong>\uff1a\u8dc3\u5c42\u6bcf\u5c421\u53f0\u5916\u673a\uff0c\u51b7\u5a92\u7ba1\u8def\u77ed\u3001\u8870\u51cf\u5c11\uff0c\u4e00\u5c42\u5916\u673a\u6545\u969c\u4e8c\u5c42\u4ecd\u53ef\u6b63\u5e38\u4f7f\u7528\uff1b<br>\n        \u2461 <strong>\u6c1f\u673a+\u5730\u6696\u5404\u53f8\u5176\u804c<\/strong>\uff1a\u590f\u5b63\u6c1f\u673a\u5236\u51b7\u9ad8\u6548\uff0c\u51ac\u5b63\u5730\u6696\u8f90\u5c04\u8212\u9002\uff0c\u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\u4e92\u4e0d\u62d6\u7d2f\uff1b<br>\n        \u2462 <strong>\u9690\u853d\u5de5\u7a0b\u770b\u710a\u63a5<\/strong>\uff1a\u5145\u6c2e\u4fdd\u62a4\u710a\u662f\u6c1f\u7cfb\u7edf\u5bff\u547d\u7684\u5173\u952e\uff0c\u6c27\u5316\u76ae\u662f\u538b\u7f29\u673a\u7684\u5929\u654c\uff1b<br>\n        \u2463 <strong>\u914d\u7f6e\u7559\u4f59\u91cf<\/strong>\uff1a\u5b9e\u9645\u51b7\u6307\u6807190~207W\/\u33a1\u9ad8\u4e8e\u6210\u90fd\u5e38\u89c4\u503c\uff0c\u5e94\u5bf9\u897f\u6652\u4e0e\u5927\u7a97\u8d1f\u8377\u66f4\u4ece\u5bb9\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab3\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\u26a0\ufe0f \u98ce\u9669\u544a\u77e5\uff1a\u5b89\u88c5\u540e\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879\u5982\u5b9e\u76f8\u544a\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\u26a0\ufe0f \u98ce\u9669\u544a\u77e5\uff08\u5b89\u88c5\u540e\u63d0\u793a\uff09<\/div>\n      <div class=\"card-desc\">\n        \u2460 <strong>\u540a\u9876\u5c01\u677f\u524d\u9a8c\u6536<\/strong>\uff1a\u9690\u853d\u5de5\u7a0b\u5c01\u540a\u9876\u524d\u8bf7\u73b0\u573a\u786e\u8ba4\u4fdd\u538b\u8bfb\u6570\u4e0e\u7ba1\u8def\u7167\u7247\uff1b<br>\n        \u2461 <strong>\u98ce\u53e3\u6210\u54c1\u4fdd\u62a4<\/strong>\uff1a\u88c5\u4fee\u671f\u95f4\u98ce\u53e3\u9700\u52a0\u76d6\u4fdd\u62a4\uff0c\u9632\u6b62\u7c89\u5c18\u8fdb\u5165\u5185\u673a\uff1b<br>\n        \u2462 <strong>\u5730\u6696\u9996\u6b21\u5347\u6e29<\/strong>\uff1a\u9996\u6b21\u4f9b\u6696\u5efa\u8bae\u4f4e\u6e29\u6162\u5347\u6e29\uff08\u6bcf\u5929+5\u2103\uff09\uff0c\u4fdd\u62a4\u5730\u677f\u4e0e\u76d8\u7ba1\uff1b<br>\n        \u2463 <strong>\u5916\u673a\u6563\u70ed<\/strong>\uff1a\u5916\u673a\u4f4d\u7f6e\u4fdd\u6301\u901a\u98ce\uff0c\u52ff\u5806\u653e\u6742\u7269\u5f71\u54cd\u6563\u70ed\u6548\u7387\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab4\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\ud83d\udca1 \u4f7f\u7528\u8d34\u58eb\uff1a\u53cc\u7cfb\u7edf\u65e5\u5e38\u4f7f\u7528\u5efa\u8bae\u3002<\/div>\n    <div class=\"content-card\">\n      <div class=\"card-title\">\ud83d\udca1 \u65e5\u5e38\u4f7f\u7528\u8d34\u58eb<\/div>\n      <div class=\"card-desc\">\n        \u2460 \u590f\u5b63\u7a7a\u8c03\u8bbe\u5b9a26\u2103\u5de6\u53f3\uff0c\u914d\u5408\u98ce\u6247\u5faa\u73af\u4f53\u611f\u66f4\u8212\u9002\u66f4\u7701\u7535\uff1b<br>\n        \u2461 \u51ac\u5b63\u5730\u6696\u8bbe\u5b9a18~22\u2103\uff0c\u957f\u65f6\u95f4\u65e0\u4eba\u53ef\u8c03\u81f316\u2103\u4fdd\u6e29\uff0c\u907f\u514d\u9891\u7e41\u542f\u505c\uff1b<br>\n        \u2462 WIFI\u7ebf\u63a7\u5668\u53ef\u8fdc\u7a0b\u5f00\u5173\uff0c\u56de\u5bb6\u524d30\u5206\u949f\u9884\u51b7\/\u9884\u70ed\uff1b<br>\n        \u2463 \u8fc7\u6e21\u5b63\u8282\uff084~5\u6708\/10~11\u6708\uff09\u6210\u90fd\u6e7f\u5ea6\u5927\uff0c\u53ef\u77ed\u65f6\u5f00\u9664\u6e7f\u6a21\u5f0f\u3002\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div id=\"s5-tab5\" class=\"tab-panel\" style=\"display:none\">\n    <div class=\"conclusion-bar\">\u2753 \u9ad8\u9891\u95ee\u7b54\uff1a\u5173\u4e8e\u672c\u6848\u914d\u7f6e\u4e0e\u5de5\u827a\u7684\u5e38\u89c1\u7591\u95ee\u3002<\/div>\n    <div class=\"faq-list\">\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u4e24\u5c42\u8dc3\u5c42\u4e3a\u4ec0\u4e48\u914d\u4e24\u53f0\u5916\u673a\uff0c\u800c\u4e0d\u662f\u4e00\u53f0\u5927\u5916\u673a\uff1f<\/div><div class=\"faq-a\">\u5218\u8001\u5e08\u5bb6\u5bf9\u5206\u533a\u63a7\u5236\u8981\u6c42\u9ad8\u3002\u672c\u6848\u4e24\u53f0RAS-140FSVN7Q\u6bcf\u5c421\u53f0\uff1a\u4e00\u697c\u5916\u673a\u5e26\u516c\u533a\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c\u52a8\u533a\u9759\u533a\u5404\u81ea\u72ec\u7acb\u8fd0\u884c\uff0c\u6309\u9700\u5f00\u673a\u66f4\u8282\u80fd\uff1b\u540c\u65f6\u7ba1\u8def\u77ed\u3001\u8870\u51cf\u5c0f\uff0c\u4e00\u53f0\u6545\u969c\u53e6\u4e00\u5c42\u7167\u5e38\u4f7f\u7528\u3002<\/div><\/div>\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u7a7a\u8c03\u662f\u6c1f\u673a\uff0c\u5730\u6696\u662f\u6c34\u7cfb\u7edf\uff0c\u4e24\u5957\u7cfb\u7edf\u51b2\u7a81\u5417\uff1f<\/div><div class=\"faq-a\">\u4e0d\u51b2\u7a81\u3002\u590f\u5b63\u7531\u6c1f\u673a\u76f4\u63a5\u84b8\u53d1\u5236\u51b7\uff08\u54cd\u5e94\u5feb\u3001\u80fd\u6548\u9ad8\uff09\uff0c\u51ac\u5b63\u7531\u745e\u7f8e\u51b7\u51dd\u7089\u9a71\u52a8\u5730\u6696\u8f90\u5c04\u4f9b\u6696\uff08\u811a\u611f\u8212\u9002\uff09\u3002\u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\u3001\u72ec\u7acb\u63a7\u5236\uff0c\u5404\u81ea\u5728\u6700\u4f73\u5de5\u51b5\u4e0b\u5de5\u4f5c\u3002<\/div><\/div>\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u4e3a\u4ec0\u4e48\u9009\u745e\u7f8e\u51b7\u51dd\u7089\u505a\u5730\u6696\u70ed\u6e90\uff1f<\/div><div class=\"faq-a\">\u5218\u8001\u5e08\u975e\u5e38\u770b\u91cd\u8282\u80fd\u6027\u3002\u745e\u7f8eLL1GBQ24-CBX1-30\u4e3a\u5168\u9884\u6df7\u51b7\u51dd\u7089\uff0c\u71c3\u70e7\u6548\u7387\u9ad8\u3001\u91c7\u6696\u8fbe\u4e00\u7ea7\u80fd\u6548\uff1b\u642d\u914d\u540c\u4e3a\u4e00\u7ea7\u80fd\u6548\u7684\u96f6\u51b7\u6c34\u70ed\u6c34\u5668JSQ32-GTE11\uff0816\u5347\uff09\uff0c\u91c7\u6696+\u70ed\u6c34\u53cc\u4e00\u7ea7\u80fd\u6548\uff0c\u957f\u671f\u4f7f\u7528\u6210\u672c\u66f4\u4f4e\u3002<\/div><\/div>\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u4e8c\u697c\u7528\u70ed\u6c34\u600e\u4e48\u529e\uff1f\u71c3\u6c14\u4e0d\u662f\u4e0a\u4e0d\u4e86\u4e8c\u697c\u5417\uff1f<\/div><div class=\"faq-a\">\u539f\u8ba1\u5212\u4e8c\u697c\u5355\u72ec\u88c5\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u8fdb\u573a\u5b9a\u4f4d\u65f6\u53d1\u73b0\u71c3\u6c14\u7ba1\u9053\u65e0\u6cd5\u6539\u5230\u4e8c\u697c\u3002\u7ecf\u4e0e\u5218\u8001\u5e08\u73b0\u573a\u786e\u8ba4\uff0c\u53d8\u66f4\u4e3a\uff1a\u745e\u7f8e\u51b7\u51dd\u7089\u4e0b\u52a0\u88c5\u5faa\u73af\u6cf5\uff0c\u642d\u914d16\u5347\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\uff0c\u5168\u5c4b\u70ed\u6c34\u5373\u5f00\u5373\u70ed\uff0c\u4e8c\u697c\u65e0\u9700\u5355\u72ec\u8bbe\u5907\uff0c\u65b9\u6848\u53d8\u66f4\u516c\u5f00\u900f\u660e\u3002<\/div><\/div>\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u4e00\u5c42\u5916\u673a\u8fde\u63a5\u7387108.6%\uff0c\u4f1a\u4e0d\u4f1a\u8d85\u8d1f\u8377\uff1f<\/div><div class=\"faq-a\">\u591a\u8054\u673a\u5141\u8bb8\u8fde\u63a5\u7387\u5728100%~130%\u4e4b\u95f4\uff08\u540c\u5f00\u7387\u4f4e\u7684\u5bb6\u7528\u573a\u666f\uff09\uff0c\u5382\u5546\u8bbe\u8ba1\u5df2\u8003\u8651\u3002\u4e00\u5c423\u53f0\u5185\u673a\u540c\u5f00\u7387\u6309\u5bb6\u5ead\u6210\u5458\u4f5c\u606f\u5e76\u4e0d\u6ee1\u8d1f\u8377\uff0c\u4e14\u5355\u53f071\u5185\u673a\u672c\u8eab\u5c31\u8986\u76d6\u5ba2\u9910\u5385\u4e3b\u8d1f\u8377\uff0c108.6%\u5c5e\u5e38\u89c4\u5b89\u5168\u8303\u56f4\u3002<\/div><\/div>\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1a\u6c2e\u6c14\u4fdd\u62a4\u710a\u548c\u666e\u901a\u710a\u63a5\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/div><div class=\"faq-a\">\u666e\u901a\u710a\u63a5\u9ad8\u6e29\u4e0b\u94dc\u7ba1\u5185\u58c1\u4f1a\u4ea7\u751f\u6c27\u5316\u76ae\uff0c\u8131\u843d\u540e\u4f1a\u5835\u585e\u7cfb\u7edf\u3001\u78e8\u635f\u538b\u7f29\u673a\u3002\u5145\u6c2e\u4fdd\u62a4\u710a\u5728\u710a\u63a5\u65f6\u5411\u7ba1\u5185\u5145\u6c2e\u6c14\uff0c\u9694\u7edd\u6c27\u6c14\u907f\u514d\u6c27\u5316\uff0c\u662f\u6c1f\u7cfb\u7edf\u957f\u671f\u7a33\u5b9a\u7684\u5173\u952e\u5de5\u827a\uff0c\u4e5f\u662f\u9f99\u8109\u7cbe\u5de5\u7684\u6807\u51c6\u52a8\u4f5c\u3002<\/div><\/div>\n      <div class=\"faq-item\"><div class=\"faq-q\">Q\uff1aWIFI\u7ebf\u63a7\u5668\u6709\u4ec0\u4e48\u529f\u80fd\uff1f<\/div><div class=\"faq-a\">\u672c\u68486\u53f0\u5185\u673a\u5404\u914d1\u53f0\u65e5\u7acbWIFI\u7ebf\u63a7\u5668PC-P1HVQA\uff0c\u9664\u672c\u5730\u5f00\u5173\u8c03\u6e29\u5916\uff0c\u652f\u6301\u624b\u673aAPP\u8fdc\u7a0b\u63a7\u5236\u2014\u2014\u56de\u5bb6\u524d\u9884\u51b7\u9884\u70ed\u3001\u51fa\u95e8\u5fd8\u5173\u8fdc\u7a0b\u5173\u95ed\uff0c\u8fd8\u80fd\u67e5\u770b\u8fd0\u884c\u72b6\u6001\u3002<\/div><\/div>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================================================ -->\n<!-- S6 \u00b7 \u95e8\u5e97\u6388\u6743\u4e0e\u672c\u5730\u670d\u52a1 -->\n<!-- ============================================================ -->\n<section class=\"step-section\" id=\"s6\">\n  <div class=\"step-head\"><span class=\"step-num\">S6<\/span><span class=\"step-label\">\u95e8\u5e97\u6388\u6743\u4e0e\u672c\u5730\u670d\u52a1<\/span><\/div>\n  <div class=\"content-card\">\n    <div class=\"card-title\">\ud83c\udfea \u9f99\u8109\u6696\u901a \u00b7 \u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97<\/div>\n    <div class=\"info-row\">\n      <div class=\"info-cell\"><div class=\"store-card\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\" loading=\"lazy\"><div class=\"store-name\">\ud83d\udccd \u5357\u5bcc\u68ee\u5e97\uff08\u8fd1\u5929\u5e9c\u65b0\u533a\uff09<\/div><div class=\"store-addr\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<br>\u7535\u8bdd\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><\/div><\/div><\/div>\n      <div class=\"info-cell\"><div class=\"store-card\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\" loading=\"lazy\"><div class=\"store-name\">\ud83d\udccd \u5317\u5bcc\u68ee\u5e97<\/div><div class=\"store-addr\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7<br>\u7535\u8bdd\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><\/div><\/div><\/div>\n    <\/div>\n    <div class=\"disclaimer\">\n      <strong>\ud83d\udce2 \u9690\u79c1\u4e0e\u5408\u89c4\u58f0\u660e<\/strong><br>\n      1. \u672c\u6848\u4f8b\u4e2d\u5ba2\u6237\u59d3\u540d\u4ec5\u4fdd\u7559\u59d3\u6c0f\uff0c\u4e0d\u6d89\u53ca\u5168\u540d\u4e0e\u623f\u53f7\uff1b<br>\n      2. \u6d89\u53ca\u9020\u4ef7\u4fe1\u606f\u5df2\u6309\u516c\u53f8\u8981\u6c42\u8131\u654f\u5904\u7406\uff0c\u5177\u4f53\u62a5\u4ef7\u4ee5\u5b9e\u9645\u52d8\u6d4b\u4e3a\u51c6\uff1b<br>\n      3. \u65bd\u5de5\u5f71\u50cf\u5747\u7ecf\u5ba2\u6237\u8bb8\u53ef\u4f7f\u7528\uff0c\u6c34\u5370\u65f6\u95f4\u7528\u4e8e\u5de5\u7a0b\u7559\u8bc1\uff1b<br>\n      4. \u672c\u9875\u9762\u4e0d\u542b\u6781\u9650\u8bcd\u4e0e\u7edd\u5bf9\u5316\u7528\u8bed\uff0c\u6240\u6709\u80fd\u8017\u6570\u636e\u5747\u6807\u6ce8\u300c\u672c\u5c0f\u533a\u5b9e\u6d4b \/ \u540c\u6237\u578b\u6d4b\u7b97\u300d\u524d\u7f00\u3002\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ===== \u76f8\u5173\u6848\u4f8b\u4e13\u9898 ===== -->\n<section style=\"max-width:1100px;margin:24px auto;padding:0 4px\">\n  <div style=\"font-size:17px;font-weight:700;color:var(--deep-gold);margin:0 8px 12px\">\ud83d\udcda \u76f8\u5173\u6848\u4f8b\u4e13\u9898<\/div>\n  <div class=\"rel-grid\">\n    <a class=\"rel-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2899\" target=\"_blank\" rel=\"noopener\">\n      <div class=\"rel-title\">\u4f73\u5146\u4e1a\u73d1\u6a3e\u58f9\u53f7\u00b7\u7530\u5973\u58eb\u53e0\u62fc\u4f4f\u5b85\u5206\u8bbe\u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848<\/div>\n      <div class=\"rel-desc\">\u53e0\u62fc\u5206\u5c42\u72ec\u7acb\u53cc\u7cfb\u7edf\uff1a\u4e00\u697c\u65e5\u7acb\u8212\u4eab140\u5916\u673a\u5e26\u5ba2\u9910\u5385\uff0871+63\u5185\u673a\uff09\u3001\u4e8c\u697c125\u5916\u673a\u5e26\u5367\u5ba4\uff0c\u5206\u5c42\u6309\u9700\u8fd0\u884c\uff0c\u4e0e\u672c\u6848\u4f8b\u53cc\u5916\u673a\u5206\u5c42\u601d\u8def\u4e00\u81f4\u3002<\/div>\n    <\/a>\n    <a class=\"rel-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2748\" target=\"_blank\" rel=\"noopener\">\n      <div class=\"rel-title\">\u4fdd\u5229\u5929\u5c7f\u00b7\u6731\u8001\u5e08\u9876\u697c\u65b0\u5bb6\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u5168\u5c4b\u8212\u9002\u7cfb\u7edf<\/div>\n      <div class=\"rel-desc\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u5236\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u5730\u6696+20L\u5927\u5faa\u73af\u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u7a7a\u8c03\/\u5730\u6696\/\u70ed\u6c34\u7cfb\u7edf\u5206\u79bb\uff0c\u4e0e\u672c\u6848\u4f8b\u7cfb\u7edf\u67b6\u6784\u540c\u6b3e\u3002<\/div>\n    <\/a>\n    <a class=\"rel-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10066\" target=\"_blank\" rel=\"noopener\">\n      <div class=\"rel-title\">\u5929\u5e9c\u65b0\u533a\u7fe1\u7fe0\u548c\u60a6173\u33a1\u5730\u6696\u5b9e\u6d4b\uff5c\u745e\u7f8e\u53cc\u51b7\u51dd\u7089\u6708\u5747\u71c3\u6c14350\u5143<\/div>\n      <div class=\"rel-desc\">\u5929\u5e9c\u65b0\u533a\u4fdd\u5229\u4e07\u79d1\u7fe1\u7fe0\u548c\u60a6173\u33a1\u5168\u5c4b\u5730\u66963\u5e74\u5b9e\u6d4b\uff1a\u745e\u7f8e\u53cc\u51b7\u51dd\u58c1\u6302\u7089\u51ac\u5b63\u6708\u71c3\u6c14\u4ec5350\u5143\uff0c\u6bd4\u540c\u5c0f\u533a\u7701\u4e00\u534a\u2014\u2014\u5218\u8001\u5e08\u5bb6\u540c\u6b3e\u745e\u7f8e\u51b7\u51dd\u7089\u53c2\u8003\u3002<\/div>\n    <\/a>\n    <a class=\"rel-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2815\" target=\"_blank\" rel=\"noopener\">\n      <div class=\"rel-title\">\u4ece\"\u5929\u6c1f\u5730\u6c34\"\u5230\"\u8212\u4eab160\"\u2014\u2014\u6587\u5973\u58eb\u7a7a\u8c03+\u5730\u6696\u9884\u7b97\u4f18\u5316\u4e4b\u8def<\/div>\n      <div class=\"rel-desc\">\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u56db+100\u33a1\u6c34\u5730\u6696\uff0c\u6c1f\u673a+\u9505\u7089\u5730\u6696\u5404\u53f8\u5176\u804c\u7684\u53d6\u820d\u903b\u8f91\uff0c\u9002\u5408\u7ea0\u7ed3\u7a7a\u8c03\u5730\u6696\u600e\u4e48\u914d\u7684\u4e1a\u4e3b\u3002<\/div>\n    <\/a>\n    <a class=\"rel-card\" href=\"https:\/\/longmai-nt.com\/?page_id=5320\" target=\"_blank\" rel=\"noopener\">\n      <div class=\"rel-title\">\u4e5d\u53f7\u516c\u9986200\u33a1\u5927\u5e73\u5c42\u00b7\u4e09\u8054\u4f9b\u70ed\u6c34\u5faa\u73af\u7cfb\u7edf<\/div>\n      <div class=\"rel-desc\">\u70ed\u6c34\u5faa\u73af\u71c3\u6c14\u5b9e\u6d4b\uff1a\u96f6\u51b7\u6c34\u56de\u6c34\u6e29\u5ea6\u8282\u80fd\u8bbe\u7f6e\uff0c\u4e0e\u672c\u6848\u4f8b\"\u51b7\u51dd\u7089+\u5faa\u73af\u6cf5+\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\"\u70ed\u6c34\u65b9\u6848\u76f8\u4e92\u5370\u8bc1\u3002<\/div>\n    <\/a>\n    <a class=\"rel-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2683\" target=\"_blank\" rel=\"noopener\">\n      <div class=\"rel-title\">\u4fdd\u5229\u5929\u7a7a\u4e4b\u57ce\u00b7\u79e6\u5148\u751f500\u33a1\u5927\u5b85\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\uff08\u65e5\u7acb\u5c0a\u777f\u5168\u6548\uff09<\/div>\n      <div class=\"rel-desc\">\u8d1f\u4e8c\u5c42\u81f3\u56db\u5c426\u5c42\u5206\u5c42\u72ec\u7acb\u7cfb\u7edf\uff0c\u4f4e\u9891\u533a\u57df\u72ec\u7acb\u98ce\u7ba1\u673a\u4e0d\u63a5\u5165\u4e3b\u673a\u2014\u2014\u8dc3\u5c42\/\u591a\u5c42\u5206\u5c42\u63a7\u5236\u7684\u8fdb\u9636\u53c2\u8003\u3002<\/div>\n    <\/a>\n  <\/div>\n<\/section>\n<style>\n\/* \u76f8\u5173\u6848\u4f8b\u4e13\u9898\u5361\u7247 *\/\n.rel-grid{display:grid;grid-template-columns:repeat(3,1fr);gap:14px;padding:0 8px}\n@media(max-width:900px){.rel-grid{grid-template-columns:repeat(2,1fr)}}\n@media(max-width:600px){.rel-grid{grid-template-columns:1fr}}\n.rel-card{display:block;background:var(--white);border:1px solid #eee;border-radius:10px;padding:16px 18px;text-decoration:none;box-shadow:0 2px 8px rgba(122,90,46,.06);transition:box-shadow .2s,border-color .2s}\n.rel-card:hover{box-shadow:0 6px 16px rgba(122,90,46,.14);border-color:var(--gold)}\n.rel-title{font-size:14px;font-weight:700;color:#1a6fc4;line-height:1.5;margin-bottom:8px}\n.rel-card:hover .rel-title{color:#1256a0}\n.rel-desc{font-size:12px;color:#777;line-height:1.7}\n<\/style>\n\n<!-- ===== CTA ===== -->\n<section style=\"max-width:1100px;margin:24px auto;padding:20px 24px;text-align:center;background:var(--white);border-radius:var(--card-radius);box-shadow:var(--shadow)\">\n  <div style=\"font-size:18px;font-weight:700;color:var(--deep-gold);margin-bottom:8px\">\ud83d\udcac \u514d\u8d39\u54a8\u8be2 \u00b7 \u8054\u7cfb\u9f99\u8109\u6696\u901a<\/div>\n  <div style=\"font-size:14px;font-weight:600;color:var(--gold);margin-bottom:8px\">\u8dc3\u5c42\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\u65b9\u6848\u5b9a\u5236<\/div>\n  <div style=\"font-size:13px;color:var(--text-gray);margin-bottom:12px\">\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u540c\u6237\u578b\u53ef\u53c2\u8003\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u51fa\u65b9\u6848<\/div>\n  <div style=\"display:flex;justify-content:center;gap:12px;flex-wrap:wrap;margin-bottom:14px\">\n    <span style=\"display:inline-block;padding:10px 20px;border-radius:24px;background:linear-gradient(135deg,var(--deep-gold),var(--gold));color:#fff;font-size:14px;font-weight:700\">\ud83d\udccf \u514d\u8d39\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b<\/span>\n    <span style=\"display:inline-block;padding:10px 20px;border-radius:24px;border:1.5px solid var(--gold);color:var(--deep-gold);font-size:14px;font-weight:700;background:#faf6ec\">\ud83c\udfd7\ufe0f \u9884\u7ea6\u5de5\u5730\u53c2\u89c2<\/span>\n    <span style=\"display:inline-block;padding:10px 20px;border-radius:24px;border:1.5px solid var(--gold);color:var(--deep-gold);font-size:14px;font-weight:700;background:#faf6ec\">\ud83d\udccb \u4e0a\u95e8\u5b9a\u5236\u65b9\u6848<\/span>\n  <\/div>\n  <div style=\"font-size:16px;font-weight:700;color:var(--gold)\">\ud83d\udcde \u8303\u4e3d\u5982\uff08\u5357\u5bcc\u68ee\uff09<a href=\"tel:13398198375\" style=\"color:var(--deep-gold);text-decoration:none;margin-left:6px\">133-9819-8375<\/a><\/div>\n  <div style=\"font-size:12px;color:var(--text-light);margin-top:8px\">\u5357\u5bcc\u68ee\u5e97\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f73\u697cA348 \uff5c \u5317\u5bcc\u68ee\u5e97\uff1a\u6210\u534e\u533a5\u697c5135<\/div>\n<\/section>\n\n<footer style=\"text-align:center;padding:20px;font-size:12px;color:var(--text-light);border-top:1px solid #eee\">\n  \u9f99\u8109\u6696\u901a \u00b7 2004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6 \u00b7 \u81ea2004\u5e74\u6210\u7acb\u4ee5\u6765\u59cb\u7ec8\u4ee5\u6b63\u89c4\u6388\u6743\u3001\u89c4\u8303\u65bd\u5de5\u4e3a\u51c6\u5219<br>\n  \u5357\u5bcc\u68ee\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f73\u697cA348 \uff5c \u5317\u5bcc\u68ee\uff1a\u6210\u534e\u533a5\u697c5135<br>\n  \u9500\u552e\u987e\u95ee\uff1a\u8303\u4e3d\u5982 \uff5c \u6848\u4f8b\u5236\u4f5c\uff1a\u6768\u8212\u6587<br>\n  \u00a9 2026 \u9f99\u8109\u6696\u901a longmai-nt.com\n<\/footer>\n<script>\n\/\/ \u6eda\u52a8\u5230\u6307\u5b9a\u533a\u6bb5\nfunction scrollToSection(id){\n  document.getElementById(id).scrollIntoView({behavior:'smooth',block:'start'});\n  document.querySelectorAll('.toc-btn').forEach(b=>b.classList.remove('active'));\n  event.target.classList.add('active');\n}\n\n\/\/ \u5207\u6362Tab\u9762\u677f\nfunction switchTab(tabEl,panelId){\n  var section=tabEl.closest('.step-section');\n  section.querySelectorAll('.section-tab').forEach(t=>t.classList.remove('active'));\n  tabEl.classList.add('active');\n  section.querySelectorAll('.tab-panel').forEach(p=>p.style.display='none');\n  document.getElementById(panelId).style.display='block';\n}\n\n\/\/ \u7ffb\u8f6c\u5361\nfunction flipCard(card){card.classList.toggle('flipped')}\n\n\/\/ \u6eda\u52a8\u65f6\u81ea\u52a8\u66f4\u65b0\u5bfc\u822a\u9ad8\u4eae\nwindow.addEventListener('scroll',function(){\n  var sections=document.querySelectorAll('.step-section');\n  var btns=document.querySelectorAll('.toc-btn');\n  var current='';\n  sections.forEach(function(s){\n    if(window.scrollY>=s.offsetTop-80) current=s.id;\n  });\n  btns.forEach(function(b){\n    b.classList.remove('active');\n    if(b.getAttribute('onclick')&&b.getAttribute('onclick').indexOf(current)>-1) b.classList.add('active');\n  });\n});\n<\/script><script>\n(function(){\n  const leftBox = document.getElementById('leftBox');\n  const rightBox = document.getElementById('rightBox');\n  const lineArea = document.getElementById('lineArea');\n  const finishTip = document.querySelector('.llk-finish-tip');\n\n  let selectLeft = null;\n  let selectRight = null;\n  let matchedNum = 0;\n  const totalPair = 4;\n\n  \/\/ \u521d\u59cb\u5316\u80cc\u666f\u8272\n  document.querySelectorAll('.llk-item').forEach(item=>{\n    item.style.background = item.dataset.color;\n    item.addEventListener('click', onClickItem);\n  })\n\n  function onClickItem(e){\n    const item = e.currentTarget;\n    if(item.classList.contains('match-done')) return;\n\n    const isLeft = leftBox.contains(item);\n    const isRight = rightBox.contains(item);\n\n    \/\/ \u6e05\u9664\u65e7\u9009\u62e9\u540c\u4e00\u8fb9\n    if(isLeft){\n      if(selectLeft) selectLeft.classList.remove('selected');\n      selectLeft = item;\n    }else{\n      if(selectRight) selectRight.classList.remove('selected');\n      selectRight = item;\n    }\n    item.classList.add('selected');\n\n    \/\/ \u5de6\u53f3\u90fd\u9009\u4e2d\uff0c\u5f00\u59cb\u6821\u9a8c\n    if(selectLeft && selectRight){\n      const colorL = selectLeft.dataset.color;\n      const colorR = selectRight.dataset.color;\n      const targetL = selectLeft.dataset.target;\n      const targetR = selectRight.dataset.target;\n\n      setTimeout(()=>{\n        if(colorL === colorR && targetL === targetR){\n          \/\/ \u5339\u914d\u6210\u529f\n          drawLine(selectLeft, selectRight);\n          selectLeft.classList.add('match-done');\n          selectRight.classList.add('match-done');\n          selectLeft.querySelector('.llk-desc-box').style.display = 'block';\n          selectRight.querySelector('.llk-desc-box').style.display = 'block';\n          matchedNum++;\n          if(matchedNum >= totalPair){\n            finishTip.style.display = 'block';\n          }\n        }\n        \/\/ \u6e05\u7a7a\u9009\u4e2d\u72b6\u6001\n        selectLeft.classList.remove('selected');\n        selectRight.classList.remove('selected');\n        selectLeft = null;\n        selectRight = null;\n      }, 350);\n    }\n  }\n\n  \/\/ \u7ed8\u5236\u8fde\u7ebf\n  function drawLine(elL, elR){\n    const rectL = elL.getBoundingClientRect();\n    const rectR = elR.getBoundingClientRect();\n    const areaRect = lineArea.getBoundingClientRect();\n\n    const x1 = rectL.right - areaRect.left;\n    const y1 = rectL.top + rectL.height\/2 - areaRect.top;\n    const x2 = rectR.left - areaRect.left;\n    const y2 = rectR.top + rectR.height\/2 - areaRect.top;\n\n    const length = Math.hypot(x2-x1, y2-y1);\n    const angle = Math.atan2(y2-y1, x2-x1) * 180 \/ Math.PI;\n\n    const line = document.createElement('div');\n    line.className = 'llk-line';\n    line.style.left = x1+'px';\n    line.style.top = y1+'px';\n    line.style.width = length+'px';\n    line.style.transform = `rotate(${angle}deg)`;\n    line.style.display = 'block';\n    lineArea.appendChild(line);\n  }\n})();\n<\/script>\n<!-- 1.Article \u6587\u7ae0\u7ed3\u6784\u5316 -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"Article\",\n  \"headline\":\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\uff5c\u5218\u8001\u5e08\u65e5\u7acbVAM mini II\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696\u6848\u4f8b\",\n  \"description\":\"\u9f99\u8109\u6696\u901a\u30012004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u843d\u5730\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u5218\u8001\u5e08\u4e24\u5c42\u8dc3\u5c42\u6848\u4f8b\uff1a\u65e5\u7acbVAM mini II\u4e2d\u592e\u7a7a\u8c03\u4e24\u53f0\u5916\u673a\u5206\u5c42\u914d\u7f6e\uff0c6\u53f0\u76f4\u6d41\u53d8\u9891\u5185\u673a\u5339\u914d\u5ba2\u9910\u5385\u4e0e\u4e09\u95f4\u5367\u5ba4\uff0c\u53e6\u914d159.5\u33a1\u6c34\u5730\u669610\u56de\u8def\u5206\u5ba4\u63a7\u5236\uff1b\u6c2e\u6c14\u4fdd\u62a4\u710a+\u7cfb\u7edf\u4fdd\u538b\u7cbe\u5de5\u5de5\u827a\uff0c\u5929\u5e9c\u65b0\u533a\u53ca\u5468\u8fb9\u53ef\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u5b9a\u5236\u65b9\u6848\u3002\",\n  \"author\":{\"@type\":\"Person\",\"name\":\"\u8303\u4e3d\u5982\",\"jobTitle\":\"\u9500\u552e\u987e\u95ee\"},\n  \"publisher\":{\"@type\":\"Organization\",\"name\":\"\u9f99\u8109\u6696\u901a\"},\n  \"datePublished\":\"2026-10-21\",\n  \"dateModified\":\"2026-10-22\",\n  \"mainEntityOfPage\":\"https:\/\/longmai-nt.com\/\",\n  \"articleBody\":\"\u9f99\u8109\u6696\u901a\u30012004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u843d\u5730\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u5218\u8001\u5e08\u4e24\u5c42\u8dc3\u5c42\u6848\u4f8b\uff1a\u65e5\u7acbVAM mini II\u4e2d\u592e\u7a7a\u8c03\u4e24\u53f0\u5916\u673a\u5206\u5c42\u914d\u7f6e\uff08\u6bcf\u5c421\u53f0RAS-140FSVN7Q\uff09\uff0c\u4e00\u697c\u5916\u673a\u5e26\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c6\u53f0\u76f4\u6d41\u53d8\u9891\u5185\u673a\u6309\u9700\u5339\u914d\uff1b159.5\u33a1\u6c34\u5730\u669610\u56de\u8def\uff0c\u70ed\u6e90\u745e\u7f8eLL1GBQ24-CBX1-30\u5168\u9884\u6df7\u51b7\u51dd\u7089\uff08\u91c7\u6696\u4e00\u7ea7\u80fd\u6548\uff09\uff0c\u751f\u6d3b\u70ed\u6c34\u745e\u7f8eJSQ32-GTE11\u96f6\u51b7\u6c34\u70ed\u6c34\u566816\u5347+\u5faa\u73af\u6cf5\uff08\u70ed\u6c34\u4e00\u7ea7\u80fd\u6548\uff09\uff1b\u8fdb\u573a\u5b9a\u4f4d\u65f6\u56e0\u71c3\u6c14\u65e0\u6cd5\u4e0a\u4e8c\u697c\uff0c\u73b0\u573a\u53d8\u66f4\u4e3a\u51b7\u51dd\u7089\u4e0b\u52a0\u5faa\u73af\u6cf5\u65b9\u6848\uff1b\u6c2e\u6c14\u4fdd\u62a4\u710a+\u7cfb\u7edf\u4fdd\u538b\u7cbe\u5de5\u5de5\u827a\u3002\",\n  \"locationCreated\":{\"@type\":\"Place\",\"name\":\"\u6210\u90fd\u5e02\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\"}\n}\n<\/script>\n<!-- 2.FAQPage \u95ee\u7b54\u7ed3\u6784\u5316 -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\"@type\":\"Question\",\"name\":\"\u4e24\u5c42\u8dc3\u5c42\u4e3a\u4ec0\u4e48\u914d\u4e24\u53f0\u5916\u673a\uff0c\u800c\u4e0d\u662f\u4e00\u53f0\u5927\u5916\u673a\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5218\u8001\u5e08\u5bb6\u5bf9\u5206\u533a\u63a7\u5236\u8981\u6c42\u9ad8\u3002\u672c\u6848\u4e24\u53f0RAS-140FSVN7Q\u6bcf\u5c421\u53f0\uff1a\u4e00\u697c\u5916\u673a\u5e26\u516c\u533a\u5ba2\u9910\u5385\u52a8\u533a\u3001\u4e8c\u697c\u5916\u673a\u5e26\u5367\u5ba4\uff0c\u52a8\u533a\u9759\u533a\u5404\u81ea\u72ec\u7acb\u8fd0\u884c\uff0c\u6309\u9700\u5f00\u673a\u66f4\u8282\u80fd\uff1b\u7ba1\u8def\u77ed\u3001\u8870\u51cf\u5c0f\uff0c\u4e00\u53f0\u6545\u969c\u53e6\u4e00\u5c42\u7167\u5e38\u4f7f\u7528\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u7a7a\u8c03\u662f\u6c1f\u673a\uff0c\u5730\u6696\u662f\u6c34\u7cfb\u7edf\uff0c\u4e24\u5957\u7cfb\u7edf\u51b2\u7a81\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e0d\u51b2\u7a81\u3002\u590f\u5b63\u7531\u6c1f\u673a\u76f4\u63a5\u84b8\u53d1\u5236\u51b7\uff0c\u51ac\u5b63\u7531\u745e\u7f8e\u51b7\u51dd\u7089\u9a71\u52a8\u5730\u6696\u8f90\u5c04\u4f9b\u6696\uff0c\u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\u3001\u72ec\u7acb\u63a7\u5236\uff0c\u5404\u81ea\u5728\u6700\u4f73\u5de5\u51b5\u4e0b\u5de5\u4f5c\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e3a\u4ec0\u4e48\u9009\u745e\u7f8e\u51b7\u51dd\u7089\u505a\u5730\u6696\u70ed\u6e90\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5218\u8001\u5e08\u975e\u5e38\u770b\u91cd\u8282\u80fd\u6027\u3002\u745e\u7f8eLL1GBQ24-CBX1-30\u4e3a\u5168\u9884\u6df7\u51b7\u51dd\u7089\uff0c\u91c7\u6696\u8fbe\u4e00\u7ea7\u80fd\u6548\uff1b\u642d\u914d\u540c\u4e3a\u4e00\u7ea7\u80fd\u6548\u7684\u96f6\u51b7\u6c34\u70ed\u6c34\u5668JSQ32-GTE11\uff0816\u5347\uff09\uff0c\u91c7\u6696+\u70ed\u6c34\u53cc\u4e00\u7ea7\u80fd\u6548\uff0c\u957f\u671f\u4f7f\u7528\u6210\u672c\u66f4\u4f4e\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e8c\u697c\u7528\u70ed\u6c34\u600e\u4e48\u529e\uff1f\u71c3\u6c14\u4e0d\u662f\u4e0a\u4e0d\u4e86\u4e8c\u697c\u5417\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u539f\u8ba1\u5212\u4e8c\u697c\u5355\u72ec\u88c5\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u8fdb\u573a\u5b9a\u4f4d\u65f6\u53d1\u73b0\u71c3\u6c14\u7ba1\u9053\u65e0\u6cd5\u6539\u5230\u4e8c\u697c\u3002\u7ecf\u73b0\u573a\u786e\u8ba4\u53d8\u66f4\u4e3a\uff1a\u745e\u7f8e\u51b7\u51dd\u7089\u4e0b\u52a0\u88c5\u5faa\u73af\u6cf5\uff0c\u642d\u914d16\u5347\u96f6\u51b7\u6c34\u70ed\u6c34\u5668\uff0c\u5168\u5c4b\u70ed\u6c34\u5373\u5f00\u5373\u70ed\uff0c\u65b9\u6848\u53d8\u66f4\u516c\u5f00\u900f\u660e\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u4e00\u5c42\u5916\u673a\u8fde\u63a5\u7387108.6%\uff0c\u4f1a\u4e0d\u4f1a\u8d85\u8d1f\u8377\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u591a\u8054\u673a\u5141\u8bb8\u8fde\u63a5\u7387\u5728100%~130%\u4e4b\u95f4\uff08\u540c\u5f00\u7387\u4f4e\u7684\u5bb6\u7528\u573a\u666f\uff09\uff0c\u5382\u5546\u8bbe\u8ba1\u5df2\u8003\u8651\u3002\u4e00\u5c423\u53f0\u5185\u673a\u540c\u5f00\u7387\u6309\u5bb6\u5ead\u6210\u5458\u4f5c\u606f\u5e76\u4e0d\u6ee1\u8d1f\u8377\uff0c\u4e14\u5355\u53f071\u5185\u673a\u672c\u8eab\u5c31\u8986\u76d6\u5ba2\u9910\u5385\u4e3b\u8d1f\u8377\uff0c108.6%\u5c5e\u5e38\u89c4\u5b89\u5168\u8303\u56f4\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"\u6c2e\u6c14\u4fdd\u62a4\u710a\u548c\u666e\u901a\u710a\u63a5\u6709\u4ec0\u4e48\u533a\u522b\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u666e\u901a\u710a\u63a5\u9ad8\u6e29\u4e0b\u94dc\u7ba1\u5185\u58c1\u4f1a\u4ea7\u751f\u6c27\u5316\u76ae\uff0c\u8131\u843d\u540e\u4f1a\u5835\u585e\u7cfb\u7edf\u3001\u78e8\u635f\u538b\u7f29\u673a\u3002\u5145\u6c2e\u4fdd\u62a4\u710a\u5728\u710a\u63a5\u65f6\u5411\u7ba1\u5185\u5145\u6c2e\u6c14\uff0c\u9694\u7edd\u6c27\u6c14\u907f\u514d\u6c27\u5316\uff0c\u662f\u6c1f\u7cfb\u7edf\u957f\u671f\u7a33\u5b9a\u7684\u5173\u952e\u5de5\u827a\u3002\"}},\n    {\"@type\":\"Question\",\"name\":\"WIFI\u7ebf\u63a7\u5668\u6709\u4ec0\u4e48\u529f\u80fd\uff1f\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u672c\u68486\u53f0\u5185\u673a\u5404\u914d1\u53f0\u65e5\u7acbWIFI\u7ebf\u63a7\u5668PC-P1HVQA\uff0c\u9664\u672c\u5730\u5f00\u5173\u8c03\u6e29\u5916\uff0c\u652f\u6301\u624b\u673aAPP\u8fdc\u7a0b\u63a7\u5236\u2014\u2014\u56de\u5bb6\u524d\u9884\u51b7\u9884\u70ed\u3001\u51fa\u95e8\u5fd8\u5173\u8fdc\u7a0b\u5173\u95ed\uff0c\u8fd8\u80fd\u67e5\u770b\u8fd0\u884c\u72b6\u6001\u3002\"}}\n  ]\n}\n<\/script>\n<!-- 3.BreadcrumbList \u9762\u5305\u5c51\u5bfc\u822a -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"BreadcrumbList\",\n  \"itemListElement\":[\n    {\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9f99\u8109\u6696\u901a\u9996\u9875\",\"item\":\"https:\/\/longmai-nt.com\/\"},\n    {\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u6848\u4f8b\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=2297\"},\n    {\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u5218\u8001\u5e08\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u6848\u4f8b\"}\n  ]\n}\n<\/script>\n<!-- 4.LocalBusiness \u672c\u5730\u5546\u5bb6 -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"HVACBusiness\",\n  \"name\":\"\u9f99\u8109\u6696\u901a\",\n  \"description\":\"\u9f99\u8109\u6696\u901a\u30012004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u4e13\u6ce8\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u51c0\u6c34\u8212\u9002\u5bb6\u5c45\u7cfb\u7edf\u3002\",\n  \"url\":\"https:\/\/longmai-nt.com\/\",\n  \"telephone\":\"+86-28-86131795\",\n  \"address\":[\n    {\"@type\":\"PostalAddress\",\"name\":\"\u5357\u5bcc\u68ee\u5e97\",\"streetAddress\":\"\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\"addressLocality\":\"\u6210\u90fd\u5e02\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"addressCountry\":\"CN\"},\n    {\"@type\":\"PostalAddress\",\"name\":\"\u5317\u5bcc\u68ee\u5e97\",\"streetAddress\":\"\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697c5135\u53f7\",\"addressLocality\":\"\u6210\u90fd\u5e02\",\"addressRegion\":\"\u56db\u5ddd\u7701\",\"addressCountry\":\"CN\"}\n  ],\n  \"areaServed\":\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u53ca\u5468\u8fb9\",\n  \"openingHours\":\"Mo-Su 10:00-18:00\"\n}\n<\/script>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 2004\u5e74\u8d77\u65e5\u7acb\u6388\u6743\u5546\u5bb6  [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-15994","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u8dc3\u5c42\u51b7\u6696\u6848\u4f8b\uff0c\u65e5\u7acb VAM mini II \u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u642d\u914d 159.5\u33a1\u6c34\u5730\u6696\uff0c\u745e\u7f8e\u51b7\u51dd\u7089 + \u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u5206\u5c42\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\uff0c\u5929\u5e9c\u65b0\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u6b63\u89c4\u7cbe\u5de5\u65bd\u5de5\uff0c\u62a5\u4ef7\u900f\u660e\u65e0\u9690\u5f62\u589e\u9879\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=15994\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u8dc3\u5c42\u51b7\u6696\u6848\u4f8b\uff0c\u65e5\u7acb VAM mini II \u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u642d\u914d 159.5\u33a1\u6c34\u5730\u6696\uff0c\u745e\u7f8e\u51b7\u51dd\u7089 + \u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u5206\u5c42\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\uff0c\u5929\u5e9c\u65b0\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u6b63\u89c4\u7cbe\u5de5\u65bd\u5de5\uff0c\u62a5\u4ef7\u900f\u660e\u65e0\u9690\u5f62\u589e\u9879\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=15994\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-22T10:33:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt1l.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994\",\"name\":\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/wktfmd-lls-dnpmt1l.jpg\",\"datePublished\":\"2026-10-22T07:44:22+00:00\",\"dateModified\":\"2026-10-22T10:33:37+00:00\",\"description\":\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u8dc3\u5c42\u51b7\u6696\u6848\u4f8b\uff0c\u65e5\u7acb VAM mini II \u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u642d\u914d 159.5\u33a1\u6c34\u5730\u6696\uff0c\u745e\u7f8e\u51b7\u51dd\u7089 + \u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u5206\u5c42\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\uff0c\u5929\u5e9c\u65b0\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u6b63\u89c4\u7cbe\u5de5\u65bd\u5de5\uff0c\u62a5\u4ef7\u900f\u660e\u65e0\u9690\u5f62\u589e\u9879\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/wktfmd-lls-dnpmt1l.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/wktfmd-lls-dnpmt1l.jpg\",\"width\":1440,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=15994#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u8dc3\u5c42\u51b7\u6696\u6848\u4f8b\uff0c\u65e5\u7acb VAM mini II \u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u642d\u914d 159.5\u33a1\u6c34\u5730\u6696\uff0c\u745e\u7f8e\u51b7\u51dd\u7089 + \u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u5206\u5c42\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\uff0c\u5929\u5e9c\u65b0\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u6b63\u89c4\u7cbe\u5de5\u65bd\u5de5\uff0c\u62a5\u4ef7\u900f\u660e\u65e0\u9690\u5f62\u589e\u9879","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=15994","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u8dc3\u5c42\u51b7\u6696\u6848\u4f8b\uff0c\u65e5\u7acb VAM mini II \u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u642d\u914d 159.5\u33a1\u6c34\u5730\u6696\uff0c\u745e\u7f8e\u51b7\u51dd\u7089 + \u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u5206\u5c42\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\uff0c\u5929\u5e9c\u65b0\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u6b63\u89c4\u7cbe\u5de5\u65bd\u5de5\uff0c\u62a5\u4ef7\u900f\u660e\u65e0\u9690\u5f62\u589e\u9879","og_url":"https:\/\/longmai-nt.com\/?page_id=15994","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-22T10:33:37+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt1l.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=15994","url":"https:\/\/longmai-nt.com\/?page_id=15994","name":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=15994#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=15994#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt1l.jpg","datePublished":"2026-10-22T07:44:22+00:00","dateModified":"2026-10-22T10:33:37+00:00","description":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u4e07\u79d1\u5929\u5e9c\u540d\u90b8\u8dc3\u5c42\u51b7\u6696\u6848\u4f8b\uff0c\u65e5\u7acb VAM mini II \u53cc\u5916\u673a\u4e2d\u592e\u7a7a\u8c03\u642d\u914d 159.5\u33a1\u6c34\u5730\u6696\uff0c\u745e\u7f8e\u51b7\u51dd\u7089 + \u96f6\u51b7\u6c34\u70ed\u6c34\uff0c\u5206\u5c42\u5206\u533a\u72ec\u7acb\u63a7\u5236\u3002\u9f99\u8109\u6696\u901a\u65e5\u7acb\u6388\u6743\u5546\u5bb6\uff0c\u6c2e\u6c14\u4fdd\u62a4\u710a\u9690\u853d\u5de5\u7a0b\u7559\u8bc1\uff0c\u5929\u5e9c\u65b0\u533a\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5357\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u6b63\u89c4\u7cbe\u5de5\u65bd\u5de5\uff0c\u62a5\u4ef7\u900f\u660e\u65e0\u9690\u5f62\u589e\u9879","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=15994#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=15994"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=15994#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt1l.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/10\/wktfmd-lls-dnpmt1l.jpg","width":1440,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=15994#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u5929\u5e9c\u65b0\u533a\u5929\u5e9c\u540d\u90b8\u00b7\u65e5\u7acb\u4e2d\u592e\u7acb\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u6848\u4f8b"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15994","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15994"}],"version-history":[{"count":8,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15994\/revisions"}],"predecessor-version":[{"id":16206,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/15994\/revisions\/16206"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15994"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}