{"id":1734,"date":"2026-05-27T15:30:42","date_gmt":"2026-05-27T07:30:42","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1734"},"modified":"2026-05-27T15:30:44","modified_gmt":"2026-05-27T07:30:44","slug":"%e6%97%a5%e7%ab%8b%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%c2%b7%e4%b8%89%e6%96%b9%e6%a1%88%e5%af%b9%e6%af%94%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1734","title":{"rendered":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\uff1a___\u9f99\u8001\u5e08____<\/strong><br><strong>\u9879\u76ee\u5730\u5740\uff1a_______<\/strong><br><strong>\u7a7a\u8c03\u9762\u79ef\uff1a\u7ea6107.2\u33a1<\/strong><br><strong>\u65b9\u6848\u987e\u95ee\uff1a\u4f59\u6653\u73b2\uff08\u9f99\u8109\u6696\u901a\uff09<\/strong><br><strong>\u65b9\u6848\u65e5\u671f\uff1a2026\u5e745\u670827\u65e5<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c1\u9879\uff1a\u7406\u89e3\u5faa\u73af\u00b7\u786e\u8ba4\u60a8\u7684\u9700\u6c42<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u5bb6\u6237\u578b\u4e3a\u4e00\u697c+\u4e8c\u697c\uff0c\u51715\u4e2a\u7a7a\u95f4\u9700\u8981\u4e2d\u592e\u7a7a\u8c03\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4e00\u697c\uff1a\u5ba2\u9910\u538546.8\u33a1\u3001\u6b21\u536711.7\u33a1<\/li>\n\n\n\n<li>\u4e8c\u697c\uff1a\u4e3b\u536728\u33a1\uff08\u9664\u8863\u5e3d\u95f4\uff09\u3001\u4e66\u623f9.7\u33a1\u3001\u6b21\u536711\u33a1<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u60a8\u5bb6\u7684\u4f7f\u7528\u7279\u70b9\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5e38\u5f002-3\u53f0\u7a7a\u8c03<\/li>\n\n\n\n<li><strong>\u5df2\u6709\u5730\u6696\u91c7\u6696<\/strong>\uff0c\u7a7a\u8c03\u53ea\u8d1f\u8d23\u5236\u51b7<\/li>\n\n\n\n<li>\u6309GB\u5236\u51b7\u8bbe\u8ba1\u6807\u51c6\u914d\u7f6e<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u7531\u4e8e\u60a8\u5df2\u6709\u5730\u6696\uff0c\u7a7a\u8c03\u4ec5\u7528\u4e8e\u5236\u51b7\uff0c\u56e0\u6b64\u6309<strong>\u5236\u51b7\u8d1f\u837780-120W\/\u33a1<\/strong>\u914d\u7f6e\uff0c\u65e0\u9700\u4e3a\u5236\u70ed\u8d85\u914d\u3002\u8fd9\u4e3a\u60a8\u8282\u7701\u4e86\u521d\u6295\u8d44\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u5e0c\u671b\u5bf9\u6bd4<strong>\u8212\u4eab\u3001VAM mini\u3001\u5c0a\u777f\u5168\u6548<\/strong>\u4e09\u4e2a\u7cfb\u5217\uff0c\u6211\u4eec\u6309\u4e09\u79cd\u5b9a\u4f4d\u5206\u522b\u914d\u7f6e\uff0c\u60a8\u81ea\u5df1\u9009\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c2\u9879\uff1a\u60a8\u7684\u9700\u6c42\u4e0e\u6237\u578b<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5efa\u7b51\u7c7b\u578b<\/strong><\/td><td>\u8dc3\u5c42<\/td><\/tr><tr><td><strong>\u5df2\u6709\u91c7\u6696<\/strong><\/td><td>\u5730\u6696\uff08\u7a7a\u8c03\u4ec5\u5236\u51b7\uff09<\/td><\/tr><tr><td><strong>\u4f7f\u7528\u4e60\u60ef<\/strong><\/td><td>\u5e38\u5f002-3\u53f0<\/td><\/tr><tr><td><strong>\u8bbe\u8ba1\u4f9d\u636e<\/strong><\/td><td>GB 50736-2012\uff0c\u5236\u51b7\u8d1f\u8377\u6807\u51c6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u5404\u7a7a\u95f4\u5185\u673a\u914d\u7f6e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u697c\u5c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u51b7\u8d1f\u8377<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u673a\u5bb9\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\uff08\u4e09\u65b9\u6848\u901a\u7528\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u4e00\u697c<\/td><td>\u5ba2\u9910\u5385<\/td><td>46.8\u33a1<\/td><td>\u7ea64.7-5.6kW<\/td><td><strong>71\u578b<\/strong><\/td><td>RPIZ-XXFSXXXD\/P<\/td><\/tr><tr><td>\u4e00\u697c<\/td><td>\u6b21\u5367<\/td><td>11.7\u33a1<\/td><td>\u7ea61.2-1.4kW<\/td><td><strong>22\u578b<\/strong><\/td><td>RPIZ-22FSXXXD\/P<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u4e3b\u5367<\/td><td>28\u33a1<\/td><td>\u7ea62.8-3.4kW<\/td><td><strong>50\u578b<\/strong><\/td><td>RPIZ-50FSXXXD\/P<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u4e66\u623f<\/td><td>9.7\u33a1<\/td><td>\u7ea61.0-1.2kW<\/td><td><strong>22\u578b<\/strong><\/td><td>RPIZ-22FSXXXD\/P<\/td><\/tr><tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>11\u33a1<\/td><td>\u7ea61.1-1.3kW<\/td><td><strong>22\u578b<\/strong><\/td><td>RPIZ-22FSXXXD\/P<\/td><\/tr><tr><td><strong>\u5408\u8ba1<\/strong><\/td><td><strong>5\u53f0\u5185\u673a<\/strong><\/td><td><\/td><td><\/td><td><strong>71+22+50+22+22 = 187<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u51b7\u8d1f\u8377\u53d6\u503c\u4f9d\u636e\uff08GB 50736-2012\uff09<\/strong>\uff1a\u5ba2\u9910\u5385\u6309120W\/\u33a1\uff08\u542b\u9633\u53f0\/\u897f\u6652\u4fee\u6b63\uff09\uff0c\u5367\u5ba4\u6309100-120W\/\u33a1\u3002\u5185\u673a\u5bb9\u91cf\u7565\u5927\u4e8e\u8ba1\u7b97\u9700\u6c42\uff0c\u7559\u6709\u5197\u4f59\u3002<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c3\u9879\uff1a\u4e09\u65b9\u6848\u901f\u89c8\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u65b9\u6848A\uff1a\u8212\u4eab\u7cfb\u5217<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u65b9\u6848B\uff1aVAM mini\u7cfb\u5217<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u65b9\u6848C\uff1a\u5c0a\u777f\u5168\u6548\u7cfb\u5217<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>\u6838\u5fc3\u5b9a\u4f4d<\/strong><\/td><td>\u9ad8\u6027\u4ef7\u6bd4\uff0c\u57fa\u7840\u51b7\u6696<\/td><td>\u8212\u9002\u5347\u7ea7\uff0c\u53ef\u6269\u5c55\u5730\u6696<\/td><td>\u5168\u80fd\u65d7\u8230\uff0c\u6e29\u6e7f\u53cc\u63a7<\/td><\/tr><tr><td><strong>\u5916\u673a\u578b\u53f7<\/strong><\/td><td>\u8212\u4eab\u5355\u98ce\u6247160\uff08RAS-160HRNAQ\uff09<\/td><td>VAM mini\u4e8c\u4ee3\u53cc\u98ce\u6247160\uff08RAS-160FSVN8Q\uff09<\/td><td>\u5c0a\u777f\u5168\u6548\u2161 160\uff08RAS-160FSXPN5Q\uff09<\/td><\/tr><tr><td><strong>\u5185\u673a\u7cfb\u5217<\/strong><\/td><td>\u8212\u4eab\u6807\u51c6\u5185\u673a<\/td><td>VAM mini\u6807\u51c6\u5185\u673a<\/td><td>\u5c0a\u777f\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td><\/tr><tr><td><strong>APF\u80fd\u6548<\/strong><\/td><td>5.50<\/td><td>5.70<\/td><td><strong>5.80<\/strong><\/td><\/tr><tr><td><strong>\u538b\u7f29\u673a<\/strong><\/td><td>\u53cc\u8f6c\u5b50<\/td><td>\u6da1\u65cb\u5f0f<\/td><td><strong>\u8865\u6c14\u589e\u7113\u53cc\u8f6c\u5b50<\/strong><\/td><\/tr><tr><td><strong>\u6e29\u6e7f\u53cc\u63a7<\/strong><\/td><td>\u274c \u65e0<\/td><td>\u274c \u65e0<\/td><td>\u2705&nbsp;<strong>\u6807\u914d<\/strong><\/td><\/tr><tr><td><strong>\u51c0\u5316\u529f\u80fd<\/strong><\/td><td>\u9009\u914dPE\u6a21\u5757<\/td><td>\u9009\u914dPE\u6a21\u5757<\/td><td>\u2705&nbsp;<strong>\u6807\u914dPE+\u51c0\u5316<\/strong><\/td><\/tr><tr><td><strong>\u8212\u723d\u6a21\u5f0f<\/strong><\/td><td>\u274c \u65e0<\/td><td>\u274c \u65e0<\/td><td>\u2705&nbsp;<strong>\u6807\u914d<\/strong><\/td><\/tr><tr><td><strong>\u5185\u673a\u6700\u4f4e\u566a\u97f3<\/strong><\/td><td>17dB<\/td><td>17dB<\/td><td>17dB<\/td><\/tr><tr><td><strong>\u5916\u673a\u5c3a\u5bf8<\/strong><\/td><td>770\u00d7980\u00d7360mm\uff08\u6700\u5c0f\uff09<\/td><td>1380\u00d7950\u00d7320mm<\/td><td>1380\u00d7950\u00d7370mm<\/td><\/tr><tr><td><strong>\u5916\u673a\u91cd\u91cf<\/strong><\/td><td>71kg\uff08\u6700\u8f7b\uff09<\/td><td>108kg<\/td><td>\u672a\u660e\u786e<\/td><\/tr><tr><td><strong>\u8d28\u4fdd<\/strong><\/td><td>5\u5e74\uff08\u4ea4\u8d39\u5ef6\u4fdd10\u5e74\uff09<\/td><td>10\u5e74\uff08\u65e5\u7acb\u6d3b\u52a8\u5ef6\u4fdd\uff09<\/td><td><strong>10\u5e74<\/strong>\uff08\u65e5\u7acb\u6d3b\u52a8\u5ef6\u4fdd\uff09<\/td><\/tr><tr><td><strong>\u6c34\u6a21\u5757\u6269\u5c55<\/strong><\/td><td>\u274c \u4e0d\u652f\u6301<\/td><td>\u2705 \u652f\u6301\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/td><td>\u2705 \u652f\u6301\uff08\u4e09\u8054\u4f9b\uff09<\/td><\/tr><tr><td><strong>\u521d\u6295\u8d44<\/strong><\/td><td><strong>\u6700\u4f4e<\/strong><\/td><td><strong>\u4e2d\u7b49<\/strong><\/td><td><strong>\u6700\u9ad8<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c4\u9879\uff1a\u65b9\u6848A\uff1a\u8212\u4eab\u7cfb\u5217\uff08\u9ad8\u6027\u4ef7\u6bd4\u00b7\u57fa\u7840\u51b7\u6696\uff09<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">4.1 \u8bbe\u8ba1\u5b9a\u4f4d<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ee1\u8db3\u57fa\u7840\u5236\u51b7\u9700\u6c42\uff0c\u9ad8\u6027\u4ef7\u6bd4\uff0c\u9002\u5408\u60a8\u5df2\u6709\u5730\u6696\u3001\u7a7a\u8c03\u53ea\u5236\u51b7\u7684\u573a\u666f\u3002\u5916\u673a\u6700\u5c0f\u6700\u8f7b\uff0c\u5b89\u88c5\u7075\u6d3b\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4.2 \u5ba4\u5916\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u578b\u53f7<\/strong><\/td><td>\u8212\u4eab\u5355\u98ce\u6247 RAS-160HRNAQ<\/td><\/tr><tr><td><strong>\u9762\u4ef7<\/strong><\/td><td>13,775\u5143<\/td><\/tr><tr><td><strong>\u6298\u6263<\/strong><\/td><td>8\u6298<\/td><\/tr><tr><td><strong>\u6298\u540e\u4ef7<\/strong><\/td><td>11,020\u5143<\/td><\/tr><tr><td><strong>\u5b89\u88c5\u8d39<\/strong><\/td><td>0\u5143<\/td><\/tr><tr><td><strong>\u5916\u673a\u5c0f\u8ba1<\/strong><\/td><td><strong>11,020\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.3 \u5ba4\u5185\u673a\uff085\u53f0\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">8\u6298\u540e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>3,513\u5143<\/td><td>2,810\u5143<\/td><td>1,600\u5143<\/td><td>4,410\u5143<\/td><\/tr><tr><td>\u4e00\u697c\u6b21\u5367<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013\u5143<\/td><td>2,410\u5143<\/td><td>1,600\u5143<\/td><td>4,010\u5143<\/td><\/tr><tr><td>\u4e8c\u697c\u4e3b\u5367<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>3,325\u5143<\/td><td>2,660\u5143<\/td><td>1,600\u5143<\/td><td>4,260\u5143<\/td><\/tr><tr><td>\u4e66\u623f<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013\u5143<\/td><td>2,410\u5143<\/td><td>1,600\u5143<\/td><td>4,010\u5143<\/td><\/tr><tr><td>\u4e8c\u697c\u6b21\u5367<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>3,013\u5143<\/td><td>2,410\u5143<\/td><td>1,600\u5143<\/td><td>4,010\u5143<\/td><\/tr><tr><td><strong>\u5185\u673a\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>20,700\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.4 \u7ebf\u63a7\u5668<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>WiFi\u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>5\u4e2a<\/td><td>200\u5143<\/td><td>1,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.5 \u65b9\u6848A\u603b\u4ef7<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91d1\u989d<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a\uff08\u542b\u5b89\u88c5\uff09<\/td><td>11,020\u5143<\/td><\/tr><tr><td>5\u53f0\u5185\u673a\uff08\u542b\u5b89\u88c5\uff09<\/td><td>20,700\u5143<\/td><\/tr><tr><td>5\u4e2aWiFi\u7ebf\u63a7\u5668<\/td><td>1,000\u5143<\/td><\/tr><tr><td><strong>\u65b9\u6848\u5408\u8ba1<\/strong><\/td><td><strong>32,720\u5143<\/strong><\/td><\/tr><tr><td>\u4f1a\u5458\u6696\u901a\u91d1\u989d\u62b5\u6263\u56fd\u8865\u62b5\u6263<\/td><td>-3000\u5143<\/td><\/tr><tr><td><strong>\u5b9e\u4ed8\u91d1\u989d<\/strong><\/td><td><strong>29720\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.6 \u8d85\u914d\u7387\u6838\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673a\u5bb9\u91cf<\/td><td>160<\/td><\/tr><tr><td>\u5185\u673a\u603b\u5bb9\u91cf<\/td><td>71+22+50+22+22 = 187<\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>187 \u00f7 160 \u00d7 100% =&nbsp;<strong>117%<\/strong><\/td><\/tr><tr><td><strong>\u7ed3\u8bba<\/strong><\/td><td>\u2705 \u572890%-130%\u7406\u60f3\u533a\u95f4\u5185<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c5\u9879\uff1a\u65b9\u6848B\uff1aVAM mini\u7cfb\u5217\uff08\u8212\u9002\u5347\u7ea7\u00b7\u53ef\u6269\u5c55\u5730\u6696\uff09<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">5.1 \u8bbe\u8ba1\u5b9a\u4f4d<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u91c7\u7528\u6da1\u65cb\u538b\u7f29\u673a\uff0c\u8fd0\u884c\u66f4\u7a33\u5b9a\uff0cAPF\u80fd\u6548\u66f4\u9ad8\u3002\u652f\u6301\u5916\u63a5\u6c34\u6a21\u5757\uff0c\u672a\u6765\u53ef\u5347\u7ea7\u5929\u6c1f\u5730\u6c34\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5.2 \u5ba4\u5916\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u578b\u53f7<\/strong><\/td><td>VAM mini\u4e8c\u4ee3\u53cc\u98ce\u6247 RAS-160FSVN8Q<\/td><\/tr><tr><td><strong>\u9762\u4ef7<\/strong><\/td><td>22,525\u5143\uff08\u53c2\u8003\uff09<\/td><\/tr><tr><td><strong>\u6298\u6263<\/strong><\/td><td>8\u6298<\/td><\/tr><tr><td><strong>\u6298\u540e\u4ef7<\/strong><\/td><td>18,020\u5143<\/td><\/tr><tr><td><strong>\u5b89\u88c5\u8d39<\/strong><\/td><td>600\u5143<\/td><\/tr><tr><td><strong>\u5916\u673a\u5c0f\u8ba1<\/strong><\/td><td><strong>18,620\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.3 \u5ba4\u5185\u673a\uff085\u53f0\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">8\u6298\u540e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-71FSVNAQD\/P<\/td><td>4,963\u5143<\/td><td>3,970\u5143<\/td><td>1,600\u5143<\/td><td>5,570\u5143<\/td><\/tr><tr><td>\u4e00\u697c\u6b21\u5367<\/td><td>RPIZ-22FSVNAQD\/P<\/td><td>4,313\u5143<\/td><td>3,450\u5143<\/td><td>1,600\u5143<\/td><td>5,050\u5143<\/td><\/tr><tr><td>\u4e8c\u697c\u4e3b\u5367<\/td><td>RPIZ-50FSVNAQD\/P<\/td><td>4,788\u5143<\/td><td>3,830\u5143<\/td><td>1,600\u5143<\/td><td>5,430\u5143<\/td><\/tr><tr><td>\u4e66\u623f<\/td><td>RPIZ-22FSVNAQD\/P<\/td><td>4,313\u5143<\/td><td>3,450\u5143<\/td><td>1,600\u5143<\/td><td>5,050\u5143<\/td><\/tr><tr><td>\u4e8c\u697c\u6b21\u5367<\/td><td>RPIZ-22FSVNAQD\/P<\/td><td>4,313\u5143<\/td><td>3,450\u5143<\/td><td>1,600\u5143<\/td><td>5,050\u5143<\/td><\/tr><tr><td><strong>\u5185\u673a\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>26,150\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.4 \u7ebf\u63a7\u5668<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>WiFi\u7ebf\u63a7\u5668<\/td><td>PC-P1HVQA<\/td><td>5\u4e2a<\/td><td>200\u5143<\/td><td>1,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.5 \u65b9\u6848B\u603b\u4ef7<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91d1\u989d<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a\uff08\u542b\u5b89\u88c5\uff09<\/td><td>18,620\u5143<\/td><\/tr><tr><td>5\u53f0\u5185\u673a\uff08\u542b\u5b89\u88c5\uff09<\/td><td>26,150\u5143<\/td><\/tr><tr><td>5\u4e2aWiFi\u7ebf\u63a7\u5668<\/td><td>1,000\u5143<\/td><\/tr><tr><td><strong>\u65b9\u6848\u5408\u8ba1<\/strong><\/td><td><strong>45,770\u5143<\/strong><\/td><\/tr><tr><td>\u4f1a\u5458\uff0c\u6d3b\u52a8\u56fd\u8865\uff0cMin\u673a\u578b\u7279\u4ef7\u8865\u8d34<\/td><td><\/td><\/tr><tr><td><strong>\u5b9e\u4ed8\u91d1\u989d<\/strong><\/td><td><strong>36554\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">5.6 \u8d85\u914d\u7387\u6838\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673a\u5bb9\u91cf<\/td><td>160<\/td><\/tr><tr><td>\u5185\u673a\u603b\u5bb9\u91cf<\/td><td>71+22+50+22+22 = 187<\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>187 \u00f7 160 \u00d7 100% =&nbsp;<strong>117%<\/strong><\/td><\/tr><tr><td><strong>\u7ed3\u8bba<\/strong><\/td><td>\u2705 \u572890%-130%\u7406\u60f3\u533a\u95f4\u5185<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c6\u9879\uff1a\u65b9\u6848C\uff1a\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff08\u5168\u80fd\u65d7\u8230\u00b7\u6e29\u6e7f\u53cc\u63a7\uff09<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">6.1 \u8bbe\u8ba1\u5b9a\u4f4d<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7\uff0c\u6807\u914dPE\u51c0\u5316\uff0c\u51fa\u98ce\u8212\u723d\u6a21\u5f0f\u3002\u9002\u5408\u8ffd\u6c42\u6781\u81f4\u8212\u9002\u3001\u5bf9\u7a7a\u6c14\u8d28\u91cf\u548c\u6e7f\u5ea6\u63a7\u5236\u6709\u9ad8\u8981\u6c42\u7684\u7528\u6237\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.2 \u5ba4\u5916\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u578b\u53f7<\/strong><\/td><td>\u5c0a\u777f\u5168\u6548\u2161 RAS-160FSXPN5Q<\/td><\/tr><tr><td><strong>\u9762\u4ef7<\/strong><\/td><td>20,600\u5143<\/td><\/tr><tr><td><strong>\u6298\u6263<\/strong><\/td><td>8.5\u6298<\/td><\/tr><tr><td><strong>\u6298\u540e\u4ef7<\/strong><\/td><td>17,510\u5143<\/td><\/tr><tr><td><strong>\u5b89\u88c5\u8d39<\/strong><\/td><td>600\u5143<\/td><\/tr><tr><td><strong>\u5916\u673a\u5c0f\u8ba1<\/strong><\/td><td><strong>18,110\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.3 \u5ba4\u5185\u673a\uff085\u53f0\uff09\u2014\u2014\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">8.5\u6298\u540e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8d39<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u9910\u5385<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>5,825\u5143<\/td><td>4,951\u5143<\/td><td>1,900\u5143<\/td><td>6,851\u5143<\/td><\/tr><tr><td>\u4e00\u697c\u6b21\u5367<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>5,050\u5143<\/td><td>4,293\u5143<\/td><td>1,900\u5143<\/td><td>6,193\u5143<\/td><\/tr><tr><td>\u4e8c\u697c\u4e3b\u5367<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5,663\u5143<\/td><td>4,814\u5143<\/td><td>1,900\u5143<\/td><td>6,714\u5143<\/td><\/tr><tr><td>\u4e66\u623f<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>5,050\u5143<\/td><td>4,293\u5143<\/td><td>1,900\u5143<\/td><td>6,193\u5143<\/td><\/tr><tr><td>\u4e8c\u697c\u6b21\u5367<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>5,050\u5143<\/td><td>4,293\u5143<\/td><td>1,900\u5143<\/td><td>6,193\u5143<\/td><\/tr><tr><td><strong>\u5185\u673a\u5c0f\u8ba1<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><strong>32,144\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.4 \u7ebf\u63a7\u5668<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><\/thead><tbody><tr><td>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td>PC-P1HPQA<\/td><td>5\u4e2a<\/td><td>476\u5143<\/td><td>2,380\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.5 \u65b9\u6848C\u603b\u4ef7<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91d1\u989d<\/th><\/tr><\/thead><tbody><tr><td>\u5ba4\u5916\u673a\uff08\u542b\u5b89\u88c5\uff09<\/td><td>18,110\u5143<\/td><\/tr><tr><td>5\u53f0\u5185\u673a\uff08\u542b\u5b89\u88c5\uff09<\/td><td>32,144\u5143<\/td><\/tr><tr><td>5\u4e2a\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/td><td>2,380\u5143<\/td><\/tr><tr><td><strong>\u65b9\u6848\u5408\u8ba1<\/strong><\/td><td><strong>52,634\u5143<\/strong><\/td><\/tr><tr><td>\u4f1a\u5458\u6696\u901a\u8865\u8d34\uff0c\u56fd\u8865\u6d3b\u52a8<\/td><td><\/td><\/tr><tr><td><strong>\u5b9e\u4ed8\u91d1\u989d<\/strong><\/td><td><strong>46621\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.6 \u8d85\u914d\u7387\u6838\u7b97<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><\/tr><\/thead><tbody><tr><td>\u5916\u673a\u5bb9\u91cf<\/td><td>160<\/td><\/tr><tr><td>\u5185\u673a\u603b\u5bb9\u91cf<\/td><td>71+22+50+22+22 = 187<\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>187 \u00f7 160 \u00d7 100% =&nbsp;<strong>117%<\/strong><\/td><\/tr><tr><td><strong>\u7ed3\u8bba<\/strong><\/td><td>\u2705 \u572890%-130%\u7406\u60f3\u533a\u95f4\u5185<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c7\u9879\uff1a\u4e09\u65b9\u6848\u603b\u4ef7\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u603b\u4ef7\uff08\u62b5\u6263\u524d\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6d3b\u52a8\u5230\u624b\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e0e\u65b9\u6848A\u4ef7\u5dee<\/th><\/tr><\/thead><tbody><tr><td><strong>\u65b9\u6848A<\/strong><\/td><td>\u8212\u4eab\u7cfb\u5217<\/td><td>32,720\u5143<\/td><td><strong>29720\u5143<\/strong><\/td><td>\u57fa\u51c6<\/td><\/tr><tr><td><strong>\u65b9\u6848B<\/strong><\/td><td>VAM mini\u7cfb\u5217<\/td><td>45,770\u5143<\/td><td><strong>36554\u5143<\/strong><\/td><td>+6834\u5143<\/td><\/tr><tr><td><strong>\u65b9\u6848C<\/strong><\/td><td>\u5c0a\u777f\u5168\u6548\u7cfb\u5217<\/td><td>52,634\u5143<\/td><td><strong>46621\u5143<\/strong><\/td><td>+16901\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c8\u9879\uff1a\u6838\u5fc3\u5dee\u5f02\u4e0e\u4ef7\u503c\u5206\u6790<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">8.1 \u4e09\u65b9\u6848\u6838\u5fc3\u53c2\u6570\u5bf9\u6bd4<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848A\uff08\u8212\u4eab\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848B\uff08VAM mini\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848C\uff08\u5c0a\u777f\u5168\u6548\uff09<\/th><\/tr><\/thead><tbody><tr><td><strong>APF\u80fd\u6548<\/strong><\/td><td>5.50<\/td><td>5.70<\/td><td><strong>5.80<\/strong><\/td><\/tr><tr><td><strong>\u538b\u7f29\u673a<\/strong><\/td><td>\u53cc\u8f6c\u5b50<\/td><td>\u6da1\u65cb\u5f0f<\/td><td>\u8865\u6c14\u589e\u7113\u53cc\u8f6c\u5b50<\/td><\/tr><tr><td><strong>\u5916\u673a\u566a\u97f3<\/strong><\/td><td>54dB<\/td><td>53dB<\/td><td>52-54dB<\/td><\/tr><tr><td><strong>\u5916\u673a\u5c3a\u5bf8<\/strong><\/td><td><strong>\u6700\u5c0f<\/strong>\uff08770\u00d7980\u00d7360\uff09<\/td><td>\u6700\u5927\uff081380\u00d7950\u00d7320\uff09<\/td><td>\u6700\u5927\uff081380\u00d7950\u00d7370\uff09<\/td><\/tr><tr><td><strong>\u5916\u673a\u91cd\u91cf<\/strong><\/td><td><strong>\u6700\u8f7b<\/strong>\uff0871kg\uff09<\/td><td>108kg<\/td><td>\u672a\u660e\u786e<\/td><\/tr><tr><td><strong>\u6e29\u6e7f\u53cc\u63a7<\/strong><\/td><td>\u274c<\/td><td>\u274c<\/td><td>\u2705<\/td><\/tr><tr><td><strong>\u6807\u914d\u51c0\u5316<\/strong><\/td><td>\u274c\uff08\u9009\u914d\uff09<\/td><td>\u274c\uff08\u9009\u914d\uff09<\/td><td>\u2705<\/td><\/tr><tr><td><strong>\u8212\u723d\u6a21\u5f0f<\/strong><\/td><td>\u274c<\/td><td>\u274c<\/td><td>\u2705<\/td><\/tr><tr><td><strong>\u6c34\u6a21\u5757\u6269\u5c55<\/strong><\/td><td>\u274c<\/td><td>\u2705<\/td><td>\u2705<\/td><\/tr><tr><td><strong>\u8d28\u4fdd<\/strong><\/td><td>5\u5e74\uff08\u4ea4\u8d39\u4e70\u5ef6\u4fdd10\u5e74\uff09<\/td><td>10\u5e74\uff08\u65e5\u7acb\u6d3b\u52a8\u5ef6\u4fdd\uff09<\/td><td><strong>10\u5e74<\/strong>\uff08\u65e5\u7acb\u6d3b\u52a8\u5ef6\u4fdd\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">8.2 \u4ef7\u683c\u5dee\u5f02\u5206\u6790<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4ef7\u5dee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91d1\u989d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6362\u6765\u4ec0\u4e48<\/th><\/tr><\/thead><tbody><tr><td>A\u2192B<\/td><td>+6834\u5143<\/td><td>\u6da1\u65cb\u538b\u7f29\u673a\uff08\u5bf9\u540c\u5f00\u7387\u9ad8\u7684\u60c5\u51b5\u8fd0\u884c\u66f4\u7a33\uff09\u3001APF\u63d0\u53470.2\u3001\u4f46\u662f\u5bf9\u4e8e\u5bb6\u91cc\u4f4f\u7684\u4eba\u5c11\uff0c\u4f4e\u9891\u8fd8\u662f\u53cc\u8f6c\u5b50\u66f4\u9002\u5408<\/td><\/tr><tr><td>A\u2192C<\/td><td>+16901\u5143<\/td><td>\u6e29\u6e7f\u53cc\u63a7\u3001\u6807\u914d\u51c0\u5316\u3001\u8212\u723d\u6a21\u5f0f\u300110\u5e74\u8d28\u4fdd\u3001\u53ef\u6269\u5c55\u5730\u6696\/\u70ed\u6c34\u3001APF\u63d0\u53470.3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">8.3 \u5bf9\u672c\u6237\u578b\u7684\u4ef7\u503c\u5224\u65ad<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5224\u65ad\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5206\u6790<\/th><\/tr><\/thead><tbody><tr><td><strong>\u5df2\u6709\u5730\u6696<\/strong><\/td><td>\u7a7a\u8c03\u53ea\u5236\u51b7\uff0c\u4e0d\u9700\u8981\u8003\u8651\u5236\u70ed\u80fd\u529b\u3002\u4e09\u65b9\u6848\u7684\u5236\u51b7\u80fd\u529b\u5747\u8db3\u591f<\/td><\/tr><tr><td><strong>\u5916\u673a\u4f4d<\/strong><\/td><td>\u9700\u786e\u8ba4\u5916\u673a\u4f4d\u5c3a\u5bf8\u3002\u65b9\u6848A\u5916\u673a\u6700\u5c0f\u6700\u8f7b\uff0871kg\uff09\uff0c\u5b89\u88c5\u6700\u7075\u6d3b\uff1b\u65b9\u6848B\/C\u5916\u673a\u8f83\u5927\u8f83\u91cd\uff08108kg\uff09\uff0c\u9700\u786e\u8ba4\u627f\u91cd\u548c\u7a7a\u95f4<\/td><\/tr><tr><td><strong>\u9884\u7b97\u6709\u9650<\/strong><\/td><td>\u65b9\u6848A\u6027\u4ef7\u6bd4\u6700\u9ad8\uff0c\u6ee1\u8db3\u57fa\u7840\u5236\u51b7\u9700\u6c42\u3002\u5982\u679c\u5bb6\u91cc\u4f4f\u7684\u4eba\u5c11\uff0c\u540c\u5f00\u7387\u4f4e\uff0c\u8212\u4eab\u538b\u7f29\u673a\u4f1a\u66f4\u9ad8\u6548\u3002<\/td><\/tr><tr><td><strong>\u8ffd\u6c42\u8212\u9002<\/strong><\/td><td>\u65b9\u6848C\u7684\u6e29\u6e7f\u53cc\u63a7\u5728\u6210\u90fd\u6885\u96e8\u5b63\u6709\u4ef7\u503c\uff0c\u4f46\u60a8\u5df2\u6709\u5730\u6696\uff0c\u7a7a\u8c03\u53ea\u5236\u51b7\uff0c\u9664\u6e7f\u9700\u6c42\u53ef\u53e6\u914d\u9664\u6e7f\u673a\uff08\u6210\u672c\u66f4\u4f4e\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c9\u9879\uff1a\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848A\uff08\u8212\u4eab\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848B\uff08VAM mini\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848C\uff08\u5c0a\u777f\u5168\u6548\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u52bf\u65b9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u521d\u6295\u8d44<\/strong><\/td><td>29720\u5143<\/td><td>36554\u5143<\/td><td>46621\u5143<\/td><td>\u65b9\u6848A<\/td><\/tr><tr><td><strong>\u5e74\u7535\u8d39<\/strong><\/td><td>\u57fa\u51c6<\/td><td>\u7ea6\u77013-5%<\/td><td>\u7ea6\u77015-8%<\/td><td>\u65b9\u6848C<\/td><\/tr><tr><td><strong>\u9759\u97f3\u6027<\/strong><\/td><td>\u5916\u673a54dB\/\u5185\u673a17dB<\/td><td>\u5916\u673a53dB\/\u5185\u673a17dB<\/td><td>\u5916\u673a52-54dB\/\u5185\u673a17dB<\/td><td>\u65b9\u6848C\u7565\u4f18<\/td><\/tr><tr><td><strong>\u8212\u9002\u5ea6<\/strong><\/td><td>\u57fa\u7840\u5236\u51b7<\/td><td>\u57fa\u7840\u5236\u51b7<\/td><td><strong>\u6e29\u6e7f\u53cc\u63a7+\u8212\u723d\u6a21\u5f0f<\/strong><\/td><td>\u65b9\u6848C<\/td><\/tr><tr><td><strong>\u5065\u5eb7\u529f\u80fd<\/strong><\/td><td>\u65e0\u6807\u914d\u51c0\u5316<\/td><td>\u65e0\u6807\u914d\u51c0\u5316<\/td><td><strong>\u6807\u914dPE\u51c0\u5316<\/strong><\/td><td>\u65b9\u6848C<\/td><\/tr><tr><td><strong>\u6269\u5c55\u6027<\/strong><\/td><td>\u65e0<\/td><td>\u53ef\u52a0\u5730\u6696<\/td><td>\u53ef\u52a0\u5730\u6696\/\u70ed\u6c34<\/td><td>\u65b9\u6848C<\/td><\/tr><tr><td><strong>\u8d28\u4fdd<\/strong><\/td><td>5\u5e74\u219210\u5e74\uff08\u4f1a\u5458\uff09<\/td><td>10\u5e74<\/td><td><strong>10\u5e74<\/strong><\/td><td>\u65b9\u6848BC<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c10\u9879\uff1a\u6211\u4eec\u7684\u5efa\u8bae\uff08\u8bda\u5b9e\u7248\uff09<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">10.1 \u4fe1\u4efb\u951a\u70b9\u544a\u77e5<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u60a8\u7684\u9700\u6c42\uff08\u5df2\u6709\u5730\u6696\u3001\u7a7a\u8c03\u53ea\u5236\u51b7\uff09\uff0c\u6211\u4eec\u60f3\u8bda\u5b9e\u544a\u77e5\uff1a<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u60a8\u5df2\u6709\u5730\u6696\uff0c\u7a7a\u8c03\u53ea\u9700\u8981\u5236\u51b7\u3002\u4e09\u4e2a\u65b9\u6848\u7684\u5236\u51b7\u80fd\u529b\u90fd\u8db3\u591f\uff0c\u5dee\u5f02\u4e3b\u8981\u4f53\u73b0\u5728\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u65b9\u6848A<\/strong>\uff1a\u6027\u4ef7\u6bd4\u6700\u9ad8\uff0c29720\u5143\u6ee1\u8db3\u57fa\u7840\u5236\u51b7,\u9002\u5408\u5bb6\u91cc\u4f4f\u7684\u4eba\u4e0d\u591a\uff0c\u7a7a\u8c03\u540c\u5f00\u7387\u4f4e\u7684\u60c5\u51b5\u66f4\u9ad8\u6548<\/li>\n\n\n\n<li><strong>\u65b9\u6848B<\/strong>\uff1a\u591a\u82b16834\u5143\uff0c\u6362\u6765\u6da1\u65cb\u538b\u7f29\u673a\uff0c\u5982\u679c\u5bb6\u91cc\u7a7a\u8c03\u540c\u5f00\u7387\u9ad8\u5219\u8fd0\u884c\u66f4\u7a33\u3001\u53ef\u6269\u5c55\u5730\u6696\uff08\u4f46\u60a8\u5df2\u6709\u5730\u6696\uff0c\u4e0d\u9700\u8981\uff09<\/li>\n\n\n\n<li><strong>\u65b9\u6848C<\/strong>\uff1a\u591a\u82b116901\u5143\uff0c\u6362\u6765\u6e29\u6e7f\u53cc\u63a7\u3001\u6807\u914d\u51c0\u5316\u3001\u8212\u9002\u5ea6\u5065\u5eb7\u5ea6\u66f4\u9ad8\uff0c10\u5e74\u8d28\u4fdd<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5982\u679c\u60a8\u7684\u4e3b\u8981\u8bc9\u6c42\u662f\u201c\u51b7\u5f97\u4e0b\u6765\u3001\u5b89\u9759\u3001\u7701\u5fc3\u201d\uff0c\u65b9\u6848A\u5df2\u7ecf\u8db3\u591f\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u60a8\u5bf9\u6210\u90fd\u6885\u96e8\u5b63\u7684\u6f6e\u6e7f\u7279\u522b\u5728\u610f\uff0c\u5bf9\u4e8e\u7a7a\u8c03\u5236\u51b7\u7684\u65f6\u5019\u8212\u9002\u5ea6\u8981\u6c42\u9ad8\uff0c\u4e0d\u8d8a\u5439\u8d8a\u51b7\uff0c\u51c0\u5316\u9664\u7532\u919b\u7b49\u5065\u5eb7\u8212\u9002\u8981\u6c42\u9ad8\uff0c\u5219\u65b9\u6848C\u6ee1\u8db3\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">10.2 \u9009\u578b\u5efa\u8bae<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5982\u679c\u60a8\u770b\u91cd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7406\u7531<\/th><\/tr><\/thead><tbody><tr><td><strong>\u9884\u7b97\u4f18\u5148\uff0c\u57fa\u7840\u5236\u51b7\u591f\u7528<\/strong><\/td><td><strong>\u65b9\u6848A\uff08\u8212\u4eab\uff09<\/strong><\/td><td>\u6027\u4ef7\u6bd4\u6700\u9ad8\uff0c\u5916\u673a\u6700\u5c0f\u6700\u8f7b\uff0c\u5b89\u88c5\u7075\u6d3b<\/td><\/tr><tr><td>\u6da1\u65cb\u538b\u7f29\u673a\uff0c\u8fd0\u884c\u66f4\u7a33\uff0c\u672a\u6765\u53ef\u80fd\u52a0\u5730\u6696<\/td><td>\u65b9\u6848B\uff08VAM mini\uff09<\/td><td>\u5dee\u4ef76834\u5143\u6362\u6765\u7684\u4ef7\u503c\u4e0d\u4e00\u5b9a\u662f\u60a8\u9700\u8981\u7684\uff0c\u9ad8\u9891\u9ad8\u6548\u9002\u5408\u540c\u5f00\u7387\u9ad8\u7684<\/td><\/tr><tr><td>\u6e29\u6e7f\u53cc\u63a7\u3001\u4e0d\u4f1a\u8d8a\u5439\u8d8a\u51b7\uff0c\u6807\u914d\u51c0\u5316\u300110\u5e74\u8d28\u4fdd<\/td><td>\u65b9\u6848C\uff08\u5c0a\u777f\u5168\u6548\uff09<\/td><td>\u9884\u7b97\u5145\u8db3\u3001\u8ffd\u6c42\u6781\u81f4\u8212\u9002\u53ef\u9009<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6211\u4eec\u7684\u5efa\u8bae\uff1a<\/strong>\u00a0\u60a8\u5df2\u6709\u5730\u6696\uff0c\u7a7a\u8c03\u53ea\u5236\u51b7\uff0c<strong>\u65b9\u6848A\uff08\u8212\u4eab\uff09\u662f\u6700\u52a1\u5b9e\u7684\u9009\u62e9<\/strong>\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c11\u9879\uff1a\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/strong><\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td><strong>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/strong><\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><\/tr><tr><td><strong>\u900f\u660e\u62a5\u4ef7<\/strong><\/td><td>\u8bbe\u5907+\u5b89\u88c5\u5206\u5217\uff0c\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td><strong>\u5de5\u7a0b\u8d28\u4fdd<\/strong><\/td><td>5\u5e74<\/td><\/tr><tr><td><strong>\u5382\u5bb6\u8d28\u4fdd<\/strong><\/td><td>\u8212\u4eab5\u5e74\uff08\u4f1a\u5458\u5ef6\u4fdd10\u5e74\uff09\/VAM mini 5\u5e74\/\u5c0a\u777f\u5168\u654810\u5e74<\/td><\/tr><tr><td><strong>\u4f1a\u5458\u670d\u52a1<\/strong><\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192+\u4f18\u5148\u54cd\u5e94+\u670d\u52a1\u6298\u6263<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7b2c12\u9879\uff1a\u65b9\u6848\u786e\u8ba4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u786e\u8ba4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u25a1<\/td><td><strong>\u65b9\u6848A<\/strong>\uff1a\u8212\u4eab\u7cfb\u5217\uff0c\u603b\u4ef729720\u5143<\/td><\/tr><tr><td>\u25a1<\/td><td><strong>\u65b9\u6848B<\/strong>\uff1aVAM mini\u7cfb\u5217\uff0c\u603b\u4ef736554\u5143<\/td><\/tr><tr><td>\u25a1<\/td><td><strong>\u65b9\u6848C<\/strong>\uff1a\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff0c\u603b\u4ef746621\u5143<\/td><\/tr><tr><td>\u25a1<\/td><td>\u60a8\u66f4\u503e\u5411\u4e8e\u54ea\u4e2a\u65b9\u6848\uff1f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u987e\u95ee\uff1a\u4f59\u6653\u73b2<\/strong><br><strong>\u8054\u7cfb\u65b9\u5f0f\uff1a13008113409<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u6696\u901a | \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\uff1a___\u9f99\u8001\u5e08____\u9879\u76ee\u5730\u5740\uff1a__ [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1734","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"160\u4e00\u62d6\u4e94\u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u6309\u9700\u81ea\u9009\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1734\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"160\u4e00\u62d6\u4e94\u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u6309\u9700\u81ea\u9009\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1734\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-27T07:30:44+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1734\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1734\",\"name\":\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-05-27T07:30:42+00:00\",\"dateModified\":\"2026-05-27T07:30:44+00:00\",\"description\":\"160\u4e00\u62d6\u4e94\u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u6309\u9700\u81ea\u9009\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1734#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1734\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1734#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","description":"160\u4e00\u62d6\u4e94\u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u6309\u9700\u81ea\u9009\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1734","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"160\u4e00\u62d6\u4e94\u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u6309\u9700\u81ea\u9009\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=1734","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-05-27T07:30:44+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1734","url":"https:\/\/longmai-nt.com\/?page_id=1734","name":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-05-27T07:30:42+00:00","dateModified":"2026-05-27T07:30:44+00:00","description":"160\u4e00\u62d6\u4e94\u4e09\u65b9\u6848\u5bf9\u6bd4\uff0c\u6309\u9700\u81ea\u9009\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1734#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1734"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1734#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u00b7\u4e09\u65b9\u6848\u5bf9\u6bd4\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1734","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1734"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1734\/revisions"}],"predecessor-version":[{"id":1735,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1734\/revisions\/1735"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1734"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}