{"id":18096,"date":"2026-11-04T17:59:55","date_gmt":"2026-11-04T09:59:55","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=18096"},"modified":"2026-11-21T17:00:29","modified_gmt":"2026-11-21T09:00:29","slug":"%e6%88%90%e9%83%bd%e6%b0%b4%e6%9c%ba%e4%b8%a4%e8%81%94%e4%be%9b%e6%96%bd%e5%b7%a5%e5%ae%89%e8%a3%85%e5%85%a8%e6%b5%81%e7%a8%8b%ef%bc%9a52%e6%ad%a5%e5%ae%9e%e6%8b%8d%ef%bc%8c%e4%bb%8e%e5%ae%9a%e4%bd%8d","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=18096","title":{"rendered":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8"},"content":{"rendered":"<div class=\"lmnt-plan\" id=\"lmnt18096\">\n<div class=\"lm-geo\" data-book=\"NT03\" data-cat=\"\u4e24\u8054\u4f9b\" data-layer=\"\u679d\" data-code=\"NT03-02-005\" data-step=\"3\" data-face=\"\" data-elem=\"\u6267\u884c\" data-q=\"\u6c34\u673a\u4e24\u8054\u4f9b\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8\u600e\u4e48\u88c5\u3001\u6bcf\u4e00\u6b65\u6309\u4ec0\u4e48\u6807\u51c6\u9a8c\u6536\uff1f\"><\/div>\n<header class=\"lmnt-hero\">\n<div class=\"lmnt-wrap\">\n<p><span class=\"lmnt-tag\">\u65bd\u5de5\u5de5\u827a\u9875<\/span><span class=\"lmnt-tag\">52 \u9053\u5de5\u5e8f\u5b9e\u62cd<\/span><span class=\"lmnt-tag\">\u6210\u90fd<\/span><\/p>\n<p>\u6c34\u673a\u4e24\u8054\u4f9b = \u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\u4e00\u5957\u7cfb\u7edf\u3002\u5b83\u88c5\u5f97\u5bf9\u4e0d\u5bf9\uff0c\u4e0d\u770b\u5e7f\u544a\u770b\u5de5\u5e8f\u2014\u2014\u8fd9\u4e00\u9875\u628a\u9f99\u8109\u6696\u901a\u7684\u5168\u5957\u65bd\u5de5\u6309 14 \u4e2a\u9636\u6bb5\u300152 \u6b65\u73b0\u573a\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5de5\u827a\u53c2\u6570\u4e0e\u9a8c\u6536\u6570\u5b57\uff0c\u88c5\u6ca1\u88c5\u5bf9\uff0c\u9010\u9879\u5bf9\u3002<\/p>\n<\/p>\n<\/div>\n<\/header>\n<div class=\"lmnt-wrap\">\n<p>\u6210\u90fd\u88c5\u6c34\u673a\u4e24\u8054\u4f9b\uff0c\u6700\u6015\u7684\u4e0d\u662f\u8bbe\u5907\uff0c\u662f\u5b89\u88c5\u88ab\u7b80\u5316\uff1a\u4fdd\u538b\u6539\u6210\u6253\u538b\u8bd5\u4e00\u4e0b\u3001\u56de\u586b\u4e0d\u5e26\u538b\u3001\u9690\u853d\u9a8c\u6536\u8d70\u8fc7\u573a\u3002\u8fd9\u4e00\u9875\u628a\u5168\u5957\u65bd\u5de5\u6d41\u7a0b\u6309\u987a\u5e8f\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u5f20\u56fe\u90fd\u662f\u5de5\u5730\u5b9e\u62cd\uff0c\u6bcf\u4e00\u6bb5\u90fd\u5e26\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u2014\u2014\u5761\u5ea6\u591a\u5c11\u3001\u538b\u529b\u591a\u5c11\u3001\u95f4\u8ddd\u591a\u5c11\u3002\u4f60\u53ef\u4ee5\u62ff\u7740\u8fd9\u4e00\u9875\u5bf9\u5de5\u5730\uff0c\u4e5f\u53ef\u4ee5\u62ff\u53bb\u5bf9\u6bd4\u522b\u5bb6\u7684\u62a5\u4ef7\u5355\u91cc\u6709\u6ca1\u6709\u8fd9\u4e9b\u5de5\u5e8f\u3002<\/p>\n<div class=\"lmnt-nav\">\n<a href=\"#dingwei\">\u524d\u671f\u5b9a\u4f4d<\/a><a href=\"#tuzhi\">\u65bd\u5de5\u56fe\u7eb8<\/a><a href=\"#jinchang\">\u8fdb\u573a\u9a8c\u6536<\/a><a href=\"#kongtiao\">\u7a7a\u8c03\u65bd\u5de5<\/a><a href=\"#yinbi\">\u7a7a\u8c03\u9690\u853d\u9a8c\u6536<\/a><a href=\"#dishinuan\">\u5730\u6696\u65bd\u5de5<\/a><a href=\"#yinyan\">\u4f1f\u661f\u9a8c\u6536<\/a><a href=\"#huitian\">\u56de\u586b<\/a><a href=\"#fushu\">\u9644\u5c5e\u8bbe\u5907<\/a><a href=\"#tiaoshi\">\u8c03\u8bd5\u4ea4\u4ed8<\/a><a href=\"#lengmei\">R32 \u4e0e\u52a0\u6c1f<\/a><a href=\"#faq\">\u5e38\u89c1\u95ee\u9898<\/a>\n<\/div>\n<section class=\"lmnt-sec\" id=\"dingwei\">\n<h2>\u524d\u671f\u5b9a\u4f4d<\/h2>\n<p>\u5b9a\u4f4d\u51b3\u5b9a\u540e\u9762\u4e8c\u5341\u5e74\u7684\u4f7f\u7528\u4f53\u9a8c\u3002\u8fd9\u4e00\u9636\u6bb5\u628a\u5185\u673a\u3001\u5916\u673a\u3001\u6e29\u63a7\u5668\u3001\u7ba1\u9053\u8d70\u5411\u3001\u7535\u6e90\u7ed9\u6c34\u5168\u90e8\u5b9a\u6b7b\uff0c\u5e76\u62cd\u7167\u7559\u6863\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/01QQDW.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u524d\u671f\u5b9a\u4f4d\" loading=\"lazy\"><figcaption><b>01 \u00b7 \u524d\u671f\u5b9a\u4f4d<\/b><br \/>\u5ba4\u5185\u673a\u907f\u5f00\u5e8a\u5934\u3001\u6c99\u53d1\u7b49\u5e38\u505c\u7559\u533a\uff0c\u9001\u56de\u98ce\u53e3\u4e0d\u77ed\u8def\uff0c\u901a\u98ce\u53e3\u524d\u4e0d\u7559\u969c\u788d\u7269\uff1b\u4e0d\u88c5\u5728\u53a8\u623f\u3001\u8bbe\u5907\u673a\u623f\u7b49\u6709\u6cb9\u6c14\u96fe\u6c14\u7684\u623f\u95f4\u3002<br \/>\u5ba4\u5916\u673a\u907f\u5f00\u5367\u5ba4\u3001\u4e66\u623f\u7b49\u5bf9\u566a\u58f0\u654f\u611f\u7684\u623f\u95f4\uff1b\u6e29\u63a7\u5668\u8ddd\u5730\u7ea6 1.4m\uff0c\u4e0e\u7167\u660e\u5f00\u5173\u9f50\u5e73\u3002<br \/>\u5b9a\u4f4d\u65f6\u5b9a\u4e0b\u7ba1\u9053\u8d70\u5411\u3001\u51b7\u51dd\u6c34\u6392\u6c34\u70b9\u3001\u5916\u673a\u7535\u6e90\u4e0e\u7ed9\u6c34\u9884\u7559\u3001\u5185\u5916\u673a\u7a7a\u5f00\u9884\u7559\uff1b\u5206\u6c34\u7bb1\u5b9c\u8bbe\u5728\u536b\u751f\u95f4\u95e8\u80cc\u540e\uff0c\u9690\u853d\u53c8\u597d\u68c0\u4fee\u3002<br \/>\u5b9a\u4f4d\u5b8c\u6210\u540e\u73b0\u573a\u62cd\u7167\u7559\u6863\uff0c\u4f5c\u4e3a\u540e\u7eed\u65bd\u5de5\u4e0e\u9a8c\u6536\u5bf9\u7167\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<div class=\"lmnt-links\">\n<p class=\"lmnt-links-t\">\u5ef6\u4f38\u9605\u8bfb<\/p>\n<p><a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=671\" target=\"_blank\"><span class=\"lmnt-card-t\">\u4e24\u8054\u4f9b\u6280\u672f\u624b\u518c<\/span><span class=\"lmnt-card-d\">\u4e24\u8054\u4f9b\u7cfb\u7edf\u600e\u4e48\u9009\u3001\u600e\u4e48\u914d\u3001\u600e\u4e48\u88c5\u7684\u603b\u5165\u53e3<\/span><\/a><a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=6342\" target=\"_blank\"><span class=\"lmnt-card-t\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u9a8c\u6536\u89c4\u8303<\/span><span class=\"lmnt-card-d\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u7684\u65bd\u5de5\u516d\u6b65\u6cd5\u4e0e\u9a8c\u6536\u6807\u51c6\uff0c\u4e0e\u672c\u9875\u540c\u4e3a\u6267\u884c\u6807\u51c6\u9875<\/span><\/a><\/div>\n<section class=\"lmnt-sec\" id=\"tuzhi\">\n<h2>\u65bd\u5de5\u56fe\u7eb8<\/h2>\n<p>\u6309\u56fd\u5bb6\u73b0\u884c\u6807\u51c6\u3001\u5730\u65b9\u6807\u51c6\u3001\u5382\u5bb6\u6280\u672f\u8d44\u6599\u4e0e\u5408\u540c\u7ea6\u5b9a\u51fa\u65bd\u5de5\u56fe\uff0c\u4e09\u65b9\u786e\u8ba4\u540e\u5f00\u5de5\uff0c\u53d8\u66f4\u6709\u8bb0\u5f55\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" class=\"lmnt-fit\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/02SGTZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u65bd\u5de5\u56fe\u7eb8\" loading=\"lazy\"><figcaption><b>02 \u00b7 \u65bd\u5de5\u56fe\u7eb8<\/b><br \/>\u65bd\u5de5\u56fe\u5305\u542b\u5185\u5916\u673a\u4f4d\u7f6e\u3001\u7ba1\u9053\u8d70\u5411\u4e0e\u7ba1\u5f84\u3001\u5206\u6c34\u7bb1\u4e0e\u6e29\u63a7\u5668\u4f4d\u7f6e\u3002<br \/>\u56fe\u4e0a\u6807\u6ce8\u76d8\u7ba1\u95f4\u8ddd\u3001\u56de\u8def\u5212\u5206\u3001\u5355\u56de\u8def\u957f\u5ea6\u3001\u4f38\u7f29\u7f1d\u4f4d\u7f6e\uff0c\u5e76\u753b\u8282\u70b9\u8be6\u56fe\u4e0e\u8054\u52a8\u63a7\u5236\u63a5\u7ebf\u56fe\u3002<br \/>\u5f00\u5de5\u524d\u7531\u4e1a\u4e3b\u3001\u88c5\u4fee\u3001\u6c34\u7535\u4e09\u65b9\u786e\u8ba4\uff1b\u73b0\u573a\u4e0e\u56fe\u4e0d\u7b26\u65f6\u5f62\u6210\u53d8\u66f4\u8bb0\u5f55\uff0c\u4e0d\u8bb8\u53e3\u5934\u6539\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"jinchang\">\n<h2>\u8bbe\u5907\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/h2>\n<p>\u8bbe\u5907\u4e0e\u6750\u6599\u8fdb\u573a\u5148\u9a8c\u6536\u518d\u65bd\u5de5\uff0c\u54c1\u724c\u578b\u53f7\u89c4\u683c\u9010\u9879\u6838\u5bf9\uff0c\u4e0d\u5408\u683c\u4e0d\u8fdb\u573a\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/03KDSBJCYS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7a7a\u8c03\u8bbe\u5907\u8fdb\u573a\u9a8c\u6536\" loading=\"lazy\"><figcaption><b>03 \u00b7 \u7a7a\u8c03\u8bbe\u5907\u8fdb\u573a\u9a8c\u6536<\/b><br \/>\u5916\u673a\u62c6\u7bb1\u67e5\u5916\u89c2\u4e0e\u6362\u70ed\u5668\u7fc5\u7247\uff0c\u65e0\u78d5\u78b0\u3001\u65e0\u660e\u663e\u5012\u7247\u3002<br \/>\u5185\u673a\uff08\u98ce\u673a\u76d8\u7ba1\uff09\u67e5\u5916\u89c2\u65e0\u78d5\u78b0\u53d8\u5f62\uff1b\u578b\u53f7\u4e0e\u5408\u540c\u6e05\u5355\u4e00\u4e00\u5bf9\u5e94\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/04KDCLJCYS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7a7a\u8c03\u6750\u6599\u8fdb\u573a\u9a8c\u6536\" loading=\"lazy\"><figcaption><b>04 \u00b7 \u7a7a\u8c03\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/b><br \/>\u6838\u5bf9\u6c34\u7ba1\u4e0e\u4fdd\u6e29\u6750\u6599\u7684\u54c1\u724c\u3001\u578b\u53f7\u89c4\u683c\uff0c\u5916\u89c2\u65e0\u7834\u635f\u3002<br \/>\u6838\u5bf9\u7535\u52a8\u4e8c\u901a\u9600\u3001\u5185\u673a\u7403\u9600\u7b49\u9600\u95e8\u914d\u4ef6\uff1b\u6e05\u70b9\u540a\u67b6\u3001\u4e1d\u6746\u3001\u81a8\u80c0\u87ba\u6813\u3001\u6a61\u80f6\u51cf\u9707\u57ab\u7b49\u8f85\u6750\u3002<br \/>\u6750\u6599\u96c6\u4e2d\u5806\u653e\u3001\u6807\u8bc6\u6e05\u6670\u3001\u9632\u6f6e\u9632\u538b\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"kongtiao\">\n<h2>\u7a7a\u8c03\u6c34\u7cfb\u7edf\u65bd\u5de5<\/h2>\n<p>\u4ece\u5f00\u5b54\u5f00\u69fd\u5230\u5185\u673a\u540a\u88c5\u3001\u7ba1\u8def\u6577\u8bbe\u3001\u4fdd\u6e29\u4fdd\u538b\uff0c\u5171 20 \u9053\u5de5\u5e8f\uff0c\u662f\u6c34\u673a\u4e24\u8054\u4f9b\u7a7a\u8c03\u4fa7\u7684\u4e3b\u4f53\u5de5\u7a0b\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/05KKKCJDHYM.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5f00\u5b54\u5f00\u69fd\u53ca\u5e95\u76d2\u9884\u57cb\" loading=\"lazy\"><figcaption><b>05 \u00b7 \u5f00\u5b54\u5f00\u69fd\u53ca\u5e95\u76d2\u9884\u57cb<\/b><br \/>\u6881\u4e0a\u5f00\u5b54\u9009\u6881\u8de8\u4e2d 1\/3 \u533a\u6bb5\u3001\u6881\u9ad8\u4e2d\u90e8\uff0c\u907f\u5f00\u6881\u7aef\u3001\u6881\u5e95\u5411\u4e0a 5\uff5e10cm \u548c\u4e3b\u6b21\u6881\u4ea4\u63a5\u5904\uff1b\u5916\u5899\u5b54\u5411\u5916\u503e\u659c\u9632\u96e8\u6c34\u5012\u704c\u3002<br \/>\u627f\u91cd\u5899\u4e25\u7981\u6a2a\u5411\u5f00\u69fd\uff1b\u69fd\u6df1\u4e0d\u5927\u4e8e\u5899\u539a 1\/3\uff0c\u69fd\u6df1=\u7ba1\u5916\u5f84+10\uff5e20mm\uff0c\u7ba1\u9762\u7802\u6d46\u4fdd\u62a4\u5c42\u4e0d\u5c0f\u4e8e 15mm\uff0c\u7528\u4e13\u7528\u5f00\u69fd\u673a\u5207\u5272\u3002<br \/>\u6e29\u63a7\u5668\u5e95\u76d2\u57cb\u8bbe\u7aef\u6b63\u7262\u56fa\uff0c\u76d2\u5185\u65e0\u7802\u6d46\u6b8b\u7559\uff0c\u76d2\u53e3\u4e0e\u5899\u9762\u9f50\u5e73\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/06SNJFCBH.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5185\u673a\u9632\u5c18\u4fdd\u62a4\" loading=\"lazy\"><figcaption><b>06 \u00b7 \u5ba4\u5185\u673a\u9632\u5c18\u4fdd\u62a4<\/b><br \/>\u540a\u88c5\u524d\u51fa\u98ce\u53e3\u3001\u56de\u98ce\u53e3\u5fc5\u987b\u505a\u9632\u5c18\u4fdd\u62a4\uff0c\u9632\u6b62\u6742\u7269\u7070\u5c18\u8fdb\u673a\u7ec4\u3002<br \/>\u4fdd\u62a4\u5c42\u5916\u8d34\u6807\u8bc6\u6807\u8d34\uff0c\u6807\u6ce8\u8be5\u673a\u7ec4\u51fa\u56de\u98ce\u53e3\u5b9e\u9645\u5f00\u5b54\u5c3a\u5bf8\uff0c\u540a\u9876\u6309\u6b64\u5f00\u5b54\uff1b\u8c03\u8bd5\u524d\u4e0d\u5f97\u63d0\u524d\u62c6\u9664\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/07SNJJCSKYCLJBWGETFYSDF.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5185\u673a\u8fdb\u51fa\u6c34\u53e3\u4f9d\u6b21\u8fde\u63a5\u6ce2\u7eb9\u7ba1\u4e8c\u901a\u9600\u4e0e\u624b\u52a8\u9600\" loading=\"lazy\"><figcaption><b>07 \u00b7 \u5ba4\u5185\u673a\u8fdb\u51fa\u6c34\u53e3\u4f9d\u6b21\u8fde\u63a5\u6ce2\u7eb9\u7ba1\u4e8c\u901a\u9600\u4e0e\u624b\u52a8\u9600<\/b><br \/>\u8fdb\u51fa\u6c34\u53e3\u4f9d\u6b21\u63a5\u4e0d\u9508\u94a2\u6ce2\u7eb9\u8f6f\u8fde\u63a5\uff08\u957f 100\uff5e300mm\uff0c\u51cf\u632f\u9632\u677e\uff09\u3001\u7535\u52a8\u4e8c\u901a\u9600\u3001\u624b\u52a8\u9600\u3002<br \/>\u6bcf\u4e2a\u672b\u7aef\u90fd\u88c5\u7535\u52a8\u4e8c\u901a\u9600\uff0c\u4fdd\u8bc1\u6c34\u6d41\u5145\u8db3\u5e76\u9632\u76d8\u7ba1\u51dd\u9732\uff1b\u9600\u6746\u7bad\u5934\u4e0e\u6c34\u6d41\u65b9\u5411\u4e00\u81f4\u3002<br \/>\u7ba1\u9053\u4e0e\u9600\u4f53\u505a\u4fdd\u6e29\uff0c\u7535\u5b50\u6267\u884c\u5668\u4e0d\u5305\u8fdb\u4fdd\u6e29\u5c42\uff1b\u624b\u52a8\u9600\u63a8\u8350\u5927\u901a\u5f84\u7403\u9600\uff0c\u538b\u635f\u5c0f\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/08JTLJCYHQMSSLD.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u63a5\u5934\u8fde\u63a5\u91c7\u7528\u7ea2\u6f06\u9ebb\u4e1d\u751f\u6599\u5e26\" loading=\"lazy\"><figcaption><b>08 \u00b7 \u63a5\u5934\u8fde\u63a5\u91c7\u7528\u7ea2\u6f06\u9ebb\u4e1d\u751f\u6599\u5e26<\/b><br \/>\u7ba1\u9053\u4e0e\u9600\u95e8\u63a5\u5934\u5bc6\u5c01\u7528\u7ea2\u6f06\u3001\u9ebb\u4e1d\u3001\u751f\u6599\u5e26\u4e09\u6b65\u6cd5\uff0c\u9632\u6b62\u63a5\u53e3\u6e17\u6c34\u6f0f\u6c34\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/09SNJSPDZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5185\u673a\u6c34\u5e73\u540a\u88c5\" loading=\"lazy\"><figcaption><b>09 \u00b7 \u5ba4\u5185\u673a\u6c34\u5e73\u540a\u88c5<\/b><br \/>\u6309\u56fe\u5212\u7ebf\u5b9a\u4f4d\uff0c\u88c5\u540a\u6746\u6253\u5b54\uff1b\u56db\u6839\u540a\u6746\u3001\u4e1d\u6746\u76f4\u5f84\u4e0d\u5c0f\u4e8e M8\uff0c\u81a8\u80c0\u87ba\u6813\u5b8c\u5168\u57cb\u5165\u6df7\u51dd\u571f\u3002<br \/>\u540a\u88c5\u540e\u8c03\u81f3\u6c34\u5e73\u518d\u9501\u7d27\uff1b\u540a\u6746\u8d85 1.5m \u65f6\u5bf9\u89d2\u52a0\u4e24\u6761\u659c\u6491\u9632\u6643\u2014\u2014\u540a\u6746\u6643\u8d77\u6765\uff0c\u58f0\u97f3\u4f1a\u987a\u7740\u697c\u677f\u4f20\u5230\u697c\u4e0b\u548c\u5367\u5ba4\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/10SLMJSJZD.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u53cc\u87ba\u6bcd\u52a0\u53cc\u51cf\u9707\u57ab\" loading=\"lazy\"><figcaption><b>10 \u00b7 \u53cc\u87ba\u6bcd\u52a0\u53cc\u51cf\u9707\u57ab<\/b><br \/>\u540a\u6746\u4e0b\u65b9\u53cc\u87ba\u6bcd\u62e7\u7d27\u56fa\u5b9a\uff0c\u5e76\u52a0\u51cf\u632f\u6a61\u80f6\u57ab\uff0c\u51cf\u5c11\u8fd0\u884c\u632f\u52a8\u4f20\u5230\u697c\u677f\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/11FGAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u98ce\u7ba1\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>11 \u00b7 \u98ce\u7ba1\u5b89\u88c5<\/b><br \/>\u98ce\u7ba1\u7528\u53cc\u9762\u94dd\u7b94\u4fdd\u6e29\u590d\u5408\u677f\u62fc\u63a5\uff0c\u63a5\u7f1d\u7c98\u5408\u4e25\u5bc6\u3001\u4e0d\u6f0f\u98ce\uff0c\u6574\u4f53\u5e73\u6574\u4e0d\u626d\u66f2\u3002<br \/>\u8f6c\u5f2f\u5904\u5012\u89d2\u6210\u5706\u5f27\uff0c\u964d\u4f4e\u9001\u98ce\u963b\u529b\uff1b\u4e0e\u673a\u7ec4\u4e4b\u95f4\u7528\u96be\u71c3 B1 \u7ea7\u67d4\u6027\u8f6f\u8fde\u63a5\u3002<br \/>\u8f6c\u5f2f\u4f4d\u7f6e\u52a0\u8bbe\u540a\u67b6\uff0c\u9632\u6b62\u98ce\u7ba1\u4e0b\u5782\u53d8\u5f62\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/12GLZDJFS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7ba1\u8def\u652f\u540a\u67b6\u6577\u8bbe\" loading=\"lazy\"><figcaption><b>12 \u00b7 \u7ba1\u8def\u652f\u540a\u67b6\u6577\u8bbe<\/b><br \/>\u652f\u540a\u67b6\u95f4\u8ddd 0.8\uff5e1.0m\uff0c\u5747\u5300\u5206\u5e03\uff1b\u56fa\u5b9a\u5728\u53ef\u9760\u5efa\u7b51\u7ed3\u6784\u4e0a\u3002<br \/>\u95f4\u8ddd\u8fc7\u5927\u7ba1\u8def\u6613\u632f\u52a8\u5f02\u54cd\uff0c\u8fc7\u5c0f\u589e\u52a0\u88c5\u4fee\u914d\u5408\u96be\u5ea6\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/13SYDHW.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u4f7f\u7528\u5927\u5f27\u5f2f\" loading=\"lazy\"><figcaption><b>13 \u00b7 \u4f7f\u7528\u5927\u5f27\u5f2f<\/b><br \/>\u5f2f\u5934\u91c7\u7528\u5927\u5f27\u5f2f\uff0c\u7ba1\u8def\u8d70\u5411\u65e0\u6b7b\u6298\u3001\u65e0\u8fde\u7eed\u6025\u5f2f\uff0c\u4e0d\u589e\u5927\u6c34\u963b\uff1b\u6574\u4f53\u6a2a\u5e73\u7ad6\u76f4\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/14KDTCFPJ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5b54\u6d1e\u586b\u5145\u53d1\u6ce1\u5242\" loading=\"lazy\"><figcaption><b>14 \u00b7 \u5b54\u6d1e\u586b\u5145\u53d1\u6ce1\u5242<\/b><br \/>\u7ba1\u9053\u7a7f\u5899\u7a7f\u697c\u677f\u7f1d\u9699\u7528\u963b\u71c3\u6750\u6599\u5c01\u5835\u4e25\u5bc6\uff0c\u9632\u866b\u9f20\u4fb5\u5165\u3002<br \/>\u6d1e\u53e3\u4e24\u4fa7 400\uff5e500mm \u5904\u8bbe\u56fa\u5b9a\u70b9\uff1b\u7a7f\u5c4b\u9876\u5904\u9884\u57cb PVC \u5957\u7ba1\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/15GLZTAZZS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7ba1\u8def\u6574\u4f53\u5b89\u88c5\u5c55\u793a\" loading=\"lazy\"><figcaption><b>15 \u00b7 \u7ba1\u8def\u6574\u4f53\u5b89\u88c5\u5c55\u793a<\/b><br \/>\u70ed\u7194\u8fde\u63a5\u5145\u5206\u52a0\u70ed\u3001\u5747\u5300\u63d2\u5165\u3001\u81ea\u7136\u51b7\u5374\uff0c\u4e0d\u5f97\u65cb\u8f6c\uff1b\u7ba1\u8def\u6574\u4f53\u6a2a\u5e73\u7ad6\u76f4\uff0c\u89c2\u611f\u6574\u9f50\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/16SNJPSKCYRLJ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5185\u673a\u6392\u6c34\u53e3\u91c7\u7528\u8f6f\u8fde\u63a5\" loading=\"lazy\"><figcaption><b>16 \u00b7 \u5ba4\u5185\u673a\u6392\u6c34\u53e3\u91c7\u7528\u8f6f\u8fde\u63a5<\/b><br \/>\u5ba4\u5185\u673a\u6392\u6c34\u53e3\u91c7\u7528\u8f6f\u8fde\u63a5\uff0c\u907f\u514d\u786c\u63a5\u628a\u8bbe\u5907\u632f\u52a8\u4f20\u7ed9\u6392\u6c34\u7ba1\uff0c\u63a5\u53e3\u4e0d\u6613\u677e\u88c2\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/17LNSPSGSJZPQK.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u51b7\u51dd\u6c34\u6392\u6c34\u7ba1\u4e0a\u52a0\u88c5\u6392\u6c14\u5b54\" loading=\"lazy\"><figcaption><b>17 \u00b7 \u51b7\u51dd\u6c34\u6392\u6c34\u7ba1\u4e0a\u52a0\u88c5\u6392\u6c14\u5b54<\/b><br \/>\u51b7\u51dd\u6c34\u7ba1\u8d85\u8fc7 3m \u65f6\u5728\u6392\u6c34\u7ba1\u4e0a\u52a0\u88c5\u6392\u6c14\u5b54\uff0c\u9632\u6b62\u6c14\u5835\u6392\u6c34\u4e0d\u7545\uff1b\u6392\u6c14\u7ba1\u4e0a\u7aef\u52a0\u5f2f\u5934\u9632\u6742\u7269\u8fdb\u5165\u3002<br \/>\u6392\u6c14\u7ba1\u7981\u6b62\u88c5\u5728\u5e26\u63d0\u5347\u6c34\u6cf5\u7684\u5ba4\u5185\u673a\u4fa7\u652f\u7ba1\u4e0a\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/18KDLNSPSSY.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7a7a\u8c03\u51b7\u51dd\u6c34\u6392\u6c34\u8bd5\u9a8c\" loading=\"lazy\"><figcaption><b>18 \u00b7 \u7a7a\u8c03\u51b7\u51dd\u6c34\u6392\u6c34\u8bd5\u9a8c<\/b><br \/>\u8bbe\u5907\u6cc4\u6c34\u652f\u7ba1\u5761\u5ea6\u4e0d\u5c0f\u4e8e 1%\uff0c\u6c34\u5e73\u5e72\u7ba1\u5761\u5ea6\u4e0d\u5c0f\u4e8e 0.5%\u3002<br \/>\u5168\u90e8\u88c5\u5b8c\u505a\u704c\u6c34\u6392\u6c34\u8bd5\u9a8c\uff0c\u6392\u6c34\u987a\u7545\u3001\u65e0\u6f0f\u70b9\uff1b\u6392\u6c34\u53e3\u4e0d\u5f97\u63a5\u5165\u6c61\u6c34\u7ba1\uff0c\u9632\u5f02\u54cd\u5f02\u5473\u5e76\u8150\u8680\u6362\u70ed\u5668\u3002\u540a\u9876\u91cc\u6ca1\u7a7a\u95f4\u505a\u8db3\u5761\u5ea6\u65f6\uff0c\u5185\u673a\u8981\u5e26\u63d0\u5347\u6cf5\uff0c\u5148\u628a\u6c34\u62bd\u4e0a\u53bb\u518d\u8d70\u5761\uff1b\u6ca1\u6709\u6cf5\u53c8\u505a\u4e0d\u51fa\u5761\u5ea6\uff0c\u6c34\u5c31\u79ef\u5728\u51dd\u6c34\u76d8\u91cc\u2014\u2014\u8fd9\u662f\u540a\u9876\u6e17\u6c34\u7684\u7b2c\u4e00\u6761\u8def\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/19XTGLZGDAZZDPQF.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7cfb\u7edf\u7ba1\u8def\u6700\u9ad8\u70b9\u5b89\u88c5\u81ea\u52a8\u6392\u6c14\u9600\" loading=\"lazy\"><figcaption><b>19 \u00b7 \u7cfb\u7edf\u7ba1\u8def\u6700\u9ad8\u70b9\u5b89\u88c5\u81ea\u52a8\u6392\u6c14\u9600<\/b><br \/>\u6c34\u7cfb\u7edf\u79ef\u6c14\u4f1a\u635f\u574f\u6c34\u6cf5\u3001\u5f15\u8d77\u6c34\u6d41\u5f00\u5173\u8bef\u52a8\u4f5c\u3001\u8ba9\u6c1f\u6c34\u6362\u70ed\u5668\u7ed3\u51b0\uff0c\u5fc5\u987b\u6392\u51c0\u3002<br \/>\u81ea\u52a8\u6392\u6c14\u9600\u88c5\u5728\u7cfb\u7edf\u6700\u9ad8\u70b9\u53ca\u5c40\u90e8\u9ad8\u70b9\uff0c\u9600\u4f53\u5782\u76f4\u5411\u4e0a\uff1b\u524d\u7aef\u52a0\u7403\u9600\u65b9\u4fbf\u68c0\u4fee\u66f4\u6362\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/20BWCLYNJJKYMBLKX.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u4fdd\u6e29\u6750\u6599\u4e0e\u5185\u673a\u63a5\u53e3\u4e25\u5bc6\u4e0d\u7559\u7a7a\u9699\" loading=\"lazy\"><figcaption><b>20 \u00b7 \u4fdd\u6e29\u6750\u6599\u4e0e\u5185\u673a\u63a5\u53e3\u4e25\u5bc6\u4e0d\u7559\u7a7a\u9699<\/b><br \/>\u4f9b\u6c34\u7ba1\u4fdd\u6e29\u539a\u5ea6\u4e0d\u5c0f\u4e8e 20mm\uff0c\u51b7\u51dd\u6c34\u7ba1\u4e0d\u5c0f\u4e8e 9mm\uff1b\u7a7f\u5899\u7a7f\u697c\u677f\u4fdd\u6e29\u4e0d\u5f97\u95f4\u65ad\u3002<br \/>\u4fdd\u6e29\u63a5\u53e3\u6d82\u80f6\u7c98\u63a5\u3001\u526a\u9f50\u5e73\u6574\u65e0\u7a7a\u9699\uff0c\u7981\u6b62\u62c9\u4f38\u540e\u8fde\u63a5\uff1b\u4e0d\u5f97\u7834\u635f\u8131\u843d\u3002\u8fd9\u4e00\u6bb5\u6700\u5bb9\u6613\u88ab\u5ffd\u7565\uff1a\u6709\u88f8\u7ba1\uff0c\u6216\u8005\u63a5\u53e3\u6ca1\u7c98\u4e25\uff0c\u590f\u5929\u7ba1\u58c1\u7ed3\u9732\uff0c\u6c34\u987a\u7740\u4fdd\u6e29\u5c42\u5f80\u4e0b\u6ef4\u2014\u2014\u8fd9\u662f\u540a\u9876\u6e17\u6c34\u7684\u7b2c\u4e8c\u6761\u8def\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/21BWCWZQZTDYRLLOGODBSBT.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u4fdd\u6e29\u5c42\u5916\u6574\u9f50\u7c98\u8d34\u5e26\u6709\u65e5\u7acb Logo \u7684\u6807\u8bc6\u6807\u8d34\" loading=\"lazy\"><figcaption><b>21 \u00b7 \u4fdd\u6e29\u5c42\u5916\u6574\u9f50\u7c98\u8d34\u5e26\u6709\u65e5\u7acb Logo \u7684\u6807\u8bc6\u6807\u8d34<\/b><br \/>\u4fdd\u6e29\u5c42\u5916\u6574\u9f50\u7c98\u8d34\u5e26\u65e5\u7acb Logo \u7684\u6807\u8bc6\u6807\u8d34\uff0c\u7c98\u8d34\u5e73\u6574\u3001\u671d\u5411\u4e00\u81f4\uff0c\u8d77\u63d0\u9192\u4fdd\u62a4\u4f5c\u7528\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/22SWJAZZHNTHGJGJCZS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5916\u673a\u5b89\u88c5\u5728\u6df7\u51dd\u571f\u6216\u94a2\u7ed3\u6784\u57fa\u7840\u4e4b\u4e0a\" loading=\"lazy\"><figcaption><b>22 \u00b7 \u5ba4\u5916\u673a\u5b89\u88c5\u5728\u6df7\u51dd\u571f\u6216\u94a2\u7ed3\u6784\u57fa\u7840\u4e4b\u4e0a<\/b><br \/>\u57fa\u7840\u8bbe\u5728\u6df7\u51dd\u571f\u6216\u94a2\u7ed3\u6784\u4e0a\uff1a\u5c4b\u9876\u57fa\u7840\u9ad8\u51fa\u5c4b\u9762\u4e0d\u5c0f\u4e8e 300mm\uff0c\u8bbe\u5907\u5e73\u53f0\u4e0a\u9ad8\u51fa\u5730\u9762\u4e0d\u5c0f\u4e8e 100mm\u3002<br \/>\u652f\u67b6\u627f\u91cd\u4e0d\u5c0f\u4e8e 200kg \u4e14\u4e0d\u5c0f\u4e8e\u4eba\u673a\u603b\u91cd 2 \u500d\uff1b\u5916\u673a\u81ea\u91cd\u8d85 100kg \u65f6\u652f\u67b6\u4e0d\u5f97\u60ac\u7a7a\u5b89\u88c5\u3002<br \/>\u652f\u67b6\u4e0d\u5f97\u56fa\u5b9a\u5728\u5367\u5ba4\u3001\u4e66\u623f\u3001\u5ba2\u5385\u7b49\u566a\u58f0\u654f\u611f\u623f\u95f4\u7684\u697c\u677f\u53ca\u5916\u5899\u4e0a\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/23SWJJJAZXJJZD.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5916\u673a\u673a\u811a\u5b89\u88c5\u6a61\u80f6\u51cf\u9707\u57ab\" loading=\"lazy\"><figcaption><b>23 \u00b7 \u5ba4\u5916\u673a\u673a\u811a\u5b89\u88c5\u6a61\u80f6\u51cf\u9707\u57ab<\/b><br \/>\u5916\u673a\u6c34\u5e73\u653e\u7f6e\u3001\u4e0e\u57fa\u7840\u63a5\u89e6\u7d27\u5bc6\uff1b\u673a\u811a\u52a0\u51cf\u632f\u6a61\u80f6\u57ab\u540e\u518d\u7528\u87ba\u6813\u9501\u7d27\uff0c\u8fd0\u884c\u5e73\u7a33\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/24KDGLXTBYSY.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7a7a\u8c03\u7ba1\u8def\u7cfb\u7edf\u4fdd\u538b\u8bd5\u9a8c\" loading=\"lazy\"><figcaption><b>24 \u00b7 \u7a7a\u8c03\u7ba1\u8def\u7cfb\u7edf\u4fdd\u538b\u8bd5\u9a8c<\/b><br \/>\u70ed\u7194\u8fde\u63a5\u5b8c\u6210 24 \u5c0f\u65f6\u540e\u8bd5\u538b\uff1b\u8bd5\u9a8c\u538b\u529b\u4e3a\u5de5\u4f5c\u538b\u529b 1.5 \u500d\u4e14\u4e0d\u5c0f\u4e8e 0.6MPa\u3002<br \/>\u5347\u538b\u4e0d\u5c11\u4e8e 10 \u5206\u949f\uff0c\u7a33\u538b 1 \u5c0f\u65f6\u538b\u964d\u4e0d\u8d85\u8fc7 0.05MPa\uff1b\u518d\u964d\u81f3 1.15 \u500d\u5de5\u4f5c\u538b\u529b\u7a33\u538b 2 \u5c0f\u65f6\u538b\u964d\u4e0d\u8d85\u8fc7 0.03MPa\uff0c\u5404\u8fde\u63a5\u5904\u65e0\u6e17\u6f0f\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"yinbi\">\n<h2>\u65bd\u5de5\u5de1\u68c0\u4e0e\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536<\/h2>\n<p>\u76d1\u7406\u5168\u7a0b\u5de1\u68c0\uff1b\u7a7a\u8c03\u7ba1\u8def\u9690\u853d\u524d\u7531\u76d1\u7406\u9010\u9879\u9a8c\u6536\u5e76\u586b\u5199\u9a8c\u6536\u5355\uff0c\u5408\u683c\u540e\u624d\u5141\u8bb8\u5c01\u540a\u9876\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" class=\"lmnt-fit\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/25KDYBGCYSJYSD.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u53ca\u9a8c\u6536\u5355\" loading=\"lazy\"><figcaption><b>25 \u00b7 \u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u53ca\u9a8c\u6536\u5355<\/b><br \/>\u9690\u853d\u524d\u7531\u76d1\u7406\u5230\u573a\u9010\u9879\u9a8c\u6536\uff1a\u5185\u5916\u673a\u56fa\u5b9a\u4e0e\u6c34\u5e73\u3001\u7ba1\u5f84\u8d70\u5411\u3001\u70ed\u7194\u8d28\u91cf\u3001\u652f\u540a\u67b6\u95f4\u8ddd\u3001\u51b7\u51dd\u6c34\u5761\u5ea6\u3001\u4fdd\u6e29\u539a\u5ea6\u3001\u9600\u95e8\u65b9\u5411\u3001\u8bd5\u538b\u8bb0\u5f55\u3002<br \/>\u9a8c\u6536\u5408\u683c\u586b\u5199\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\u5b58\u6863\uff0c\u4e4b\u540e\u624d\u5141\u8bb8\u5c01\u540a\u9876\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"dnjinchang\">\n<h2>\u5730\u6696\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/h2>\n<p>\u5730\u6696\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u8fb9\u754c\u4fdd\u6e29\u6761\u3001\u9600\u95e8\u7ec4\u4ef6\u9010\u9879\u9a8c\u6536\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/26DNCLJCYS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5730\u6696\u6750\u6599\u8fdb\u573a\u9a8c\u6536\" loading=\"lazy\"><figcaption><b>26 \u00b7 \u5730\u6696\u6750\u6599\u8fdb\u573a\u9a8c\u6536<\/b><br \/>\u5730\u6696\u76d8\u7ba1\u6838\u5bf9\u54c1\u724c\u3001\u89c4\u683c\u3001\u58c1\u539a\uff0c\u7ba1\u5185\u65e0\u6742\u8d28\uff1b\u5206\u96c6\u6c34\u5668\u94dc\u8d28\u6216\u4e0d\u9508\u94a2\uff0c\u65e0\u88c2\u7eb9\u7802\u773c\u3002<br \/>\u4fdd\u6e29\u677f\u5bc6\u5ea6\u4e0d\u5c0f\u4e8e 20kg\/m\u00b3\uff08\u6324\u5851\u677f\u6297\u538b\u4e0d\u5c0f\u4e8e 200kPa\uff09\uff1b\u53cd\u5c04\u819c\u67e5\u65b9\u683c\u5370\u5237\u8d28\u91cf\uff1b\u8fb9\u754c\u4fdd\u6e29\u6761\u3001\u4f38\u7f29\u7f1d\u67e5\u539a\u5ea6\u5f39\u6027\u3002<br \/>\u4e3b\u7ba1\u3001\u4fdd\u6e29\u3001\u9600\u95e8\u7ec4\u4ef6\u6309\u54c1\u724c\u578b\u53f7\u89c4\u683c\u9010\u9879\u6838\u5bf9\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"dishinuan\">\n<h2>\u5730\u6696\u65bd\u5de5<\/h2>\n<p>\u5206\u96c6\u6c34\u5668\u5b89\u88c5\u3001\u4fdd\u6e29\u677f\u53cd\u5c04\u819c\u94fa\u8bbe\u3001\u76d8\u7ba1\u65bd\u5de5\u3001\u4f38\u7f29\u7f1d\u8bbe\u7f6e\u3001\u6c34\u538b\u8bd5\u9a8c\uff0c\u5171 8 \u9053\u5de5\u5e8f\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/27FSXYFJSQAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5206\u6c34\u7bb1\u4e0e\u5206\u96c6\u6c34\u5668\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>27 \u00b7 \u5206\u6c34\u7bb1\u4e0e\u5206\u96c6\u6c34\u5668\u5b89\u88c5<\/b><br \/>\u5206\u6c34\u7bb1\u57cb\u88c5\u6c34\u5e73\u7262\u56fa\uff0c\u5b9c\u6697\u88c5\u5728\u4fbf\u4e8e\u68c0\u4fee\u7684\u4f4d\u7f6e\uff1b\u5206\u96c6\u6c34\u5668\u6c34\u5e73\u5b89\u88c5\u65f6\u4e0a\u6392\u5206\u6c34\u3001\u4e0b\u6392\u96c6\u6c34\uff0c\u4e24\u6392\u4e2d\u5fc3\u8ddd\u7ea6 200mm\uff0c\u96c6\u6c34\u5668\u4e2d\u5fc3\u8ddd\u5730\u9762\u4e0d\u5c0f\u4e8e 300mm\u3002<br \/>\u6bcf\u4e2a\u5206\u96c6\u6c34\u5668\u5206\u652f\u73af\u8def\u4e0d\u5b9c\u591a\u4e8e 8 \u8def\uff1b\u6bcf\u8def\u4f9b\u56de\u6c34\u90fd\u8bbe\u53ef\u5173\u65ad\u9600\u95e8\u3002<br \/>\u52a0\u70ed\u7ba1\u4e0e\u5206\u96c6\u6c34\u5668\u7528\u5361\u5957\u5f0f\/\u5361\u538b\u5f0f\u8fde\u63a5\uff0c\u94dc\u8fde\u63a5\u4ef6\u4e0e PPR \u7ba1\u63a5\u89e6\u9762\u5fc5\u987b\u9540\u954d\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/28DNZGSAZDDETF.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5730\u6696\u4e3b\u7ba1\u4e0a\u5b89\u88c5\u7535\u52a8\u4e8c\u901a\u9600\" loading=\"lazy\"><figcaption><b>28 \u00b7 \u5730\u6696\u4e3b\u7ba1\u4e0a\u5b89\u88c5\u7535\u52a8\u4e8c\u901a\u9600<\/b><br \/>\u5730\u6696\u4e3b\u7ba1\uff08\u5e38\u5728\u5206\u6c34\u7bb1\u5185\uff09\u88c5\u7535\u52a8\u4e8c\u901a\u9600\uff0c\u53ea\u5728\u91c7\u6696\u65f6\u6253\u5f00\u3002<br \/>\u9632\u6b62\u5236\u51b7\u65f6\u51b7\u51bb\u6c34\u8fdb\u5730\u6696\u76d8\u7ba1\uff0c\u907f\u514d\u5730\u9762\u51dd\u9732\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/29BWBPSQJFCYLBJDFT.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u4fdd\u6e29\u677f\u94fa\u8bbe\u4e14\u63a5\u7f1d\u5904\u7528\u94dd\u7b94\u80f6\u5e26\u5c01\u8d34\" loading=\"lazy\"><figcaption><b>29 \u00b7 \u4fdd\u6e29\u677f\u94fa\u8bbe\u4e14\u63a5\u7f1d\u5904\u7528\u94dd\u7b94\u80f6\u5e26\u5c01\u8d34<\/b><br \/>\u4fdd\u6e29\u677f\u62fc\u7f1d\u4e25\u5bc6\uff0c\u7834\u635f\u5904\u4fee\u8865\uff1b\u63a5\u7f1d\u7528\u94dd\u7b94\u80f6\u5e26\u5c01\u8d34\uff0c\u94fa\u8bbe\u5e73\u6574\u3002<br \/>\u539a\u5ea6\u6309\u8bbe\u8ba1\u4e0e JGJ 142-2012 \u70ed\u963b\u8981\u6c42\u6267\u884c\uff0c\u4e0d\u540c\u90e8\u4f4d\u7528\u76f8\u5e94\u539a\u5ea6\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/30PSFSM.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u94fa\u8bbe\u53cd\u5c04\u819c\" loading=\"lazy\"><figcaption><b>30 \u00b7 \u94fa\u8bbe\u53cd\u5c04\u819c<\/b><br \/>\u53cd\u5c04\u819c\u5e73\u6574\u94fa\u8bbe\u3001\u642d\u63a5\u65b9\u5411\u4e00\u81f4\uff0c\u63a5\u7f1d\u5bbd\u5ea6\u4e0d\u5c0f\u4e8e 10mm\uff0c\u7528\u80f6\u5e26\u8d34\u7262\u9632\u65bd\u5de5\u79fb\u4f4d\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/31DNPGSG.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5730\u6696\u76d8\u7ba1\u65bd\u5de5\" loading=\"lazy\"><figcaption><b>31 \u00b7 \u5730\u6696\u76d8\u7ba1\u65bd\u5de5<\/b><br \/>\u6309\u56fe\u65bd\u5de5\uff0c\u7ba1\u95f4\u8ddd\u5b89\u88c5\u8bef\u5dee\u4e0d\u5927\u4e8e 10mm\uff1b\u76d8\u7ba1\u8ddd\u5916\u5899\u5185\u8868\u9762\u4e0d\u5c0f\u4e8e 100mm\u3002<br \/>\u5851\u6599\u7ba1\u5f2f\u66f2\u534a\u5f84\u4e0d\u5c0f\u4e8e\u7ba1\u5916\u5f84 8 \u500d\uff0c\u7981\u6b62\u6b7b\u6298\u626d\u66f2\uff1b\u73af\u8def\u957f\u5ea6\u4e0e\u56fe\u7eb8\u8bef\u5dee\u4e0d\u5927\u4e8e 8%\u3002<br \/>\u586b\u5145\u5c42\u5185\u7684\u52a0\u70ed\u7ba1\u4e0d\u5f97\u8bbe\u63a5\u5934\uff0c\u574f\u4e86\u6574\u6839\u66f4\u6362\uff1b\u5404\u56de\u8def\u6807\u6ce8\u6240\u5c5e\u623f\u95f4\uff0c\u65b9\u4fbf\u5206\u5ba4\u63a7\u6e29\u63a5\u7ebf\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/32GDPLMJBWWJRXTG.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7ba1\u9053\u6392\u5217\u5bc6\u96c6\u90e8\u4f4d\u5916\u52a0\u67d4\u6027\u5957\u7ba1\" loading=\"lazy\"><figcaption><b>32 \u00b7 \u7ba1\u9053\u6392\u5217\u5bc6\u96c6\u90e8\u4f4d\u5916\u52a0\u67d4\u6027\u5957\u7ba1<\/b><br \/>\u7ba1\u9053\u6392\u5217\u5bc6\u96c6\u3001\u7ba1\u95f4\u8ddd\u5c0f\u4e8e 100mm \u7684\u90e8\u4f4d\uff0c\u52a0\u70ed\u7ba1\u5916\u52a0\u67d4\u6027\u5957\u7ba1\u3002<br \/>\u52a0\u70ed\u7ba1\u51fa\u5730\u9762\u4e0e\u5206\u96c6\u6c34\u5668\u8fde\u63a5\u5904\uff0c\u660e\u88c5\u6bb5\u52a0\u5957\u7ba1\u5e76\u9ad8\u51fa\u9762\u5c42 150\uff5e200mm\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/33SSFSZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u4f38\u7f29\u7f1d\u8bbe\u7f6e\" loading=\"lazy\"><figcaption><b>33 \u00b7 \u4f38\u7f29\u7f1d\u8bbe\u7f6e<\/b><br \/>\u5730\u9762\u9762\u79ef\u8d85 30\u33a1 \u6216\u8fb9\u957f\u8d85 6m \u65f6\uff0c\u6309\u4e0d\u5927\u4e8e 6m \u95f4\u8ddd\u8bbe\u4f38\u7f29\u7f1d\uff0c\u7f1d\u5bbd\u4e0d\u5c0f\u4e8e 8mm\u3002<br \/>\u52a0\u70ed\u7ba1\u5c3d\u91cf\u4e0d\u7a7f\u4f38\u7f29\u7f1d\uff1b\u5fc5\u987b\u7a7f\u65f6\u52a0 200mm \u957f\u5927\u4e00\u53f7\u67d4\u6027\u5957\u7ba1\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/34DNPGJSHJXSYSY.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5730\u6696\u76d8\u7ba1\u7ed3\u675f\u540e\u8fdb\u884c\u6c34\u538b\u8bd5\u9a8c\" loading=\"lazy\"><figcaption><b>34 \u00b7 \u5730\u6696\u76d8\u7ba1\u7ed3\u675f\u540e\u8fdb\u884c\u6c34\u538b\u8bd5\u9a8c<\/b><br \/>\u56de\u586b\u524d\u6c34\u538b\u8bd5\u9a8c\uff1a1.5 \u500d\u5de5\u4f5c\u538b\u529b\u4e14\u4e0d\u5c0f\u4e8e 0.6MPa\uff0c\u7a33\u538b 1 \u5c0f\u65f6\u538b\u964d\u4e0d\u5927\u4e8e 0.05MPa\uff0c\u4e0d\u6e17\u4e0d\u6f0f\u3002<br \/>\u6df7\u51dd\u571f\u586b\u5145\u5f0f\u5730\u6696\u8bd5\u538b\u505a\u4e24\u6b21\uff1a\u56de\u586b\u524d\u4e00\u6b21\u3001\u586b\u5145\u5c42\u517b\u62a4\u671f\u6ee1\u540e\u4e00\u6b21\uff1b\u51ac\u5b63\u8bd5\u538b\u540e\u628a\u7ba1\u5185\u79ef\u6c34\u5439\u51c0\u9632\u51bb\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<div class=\"lmnt-links\">\n<p class=\"lmnt-links-t\">\u5ef6\u4f38\u9605\u8bfb<\/p>\n<p><a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\"><span class=\"lmnt-card-t\">\u5730\u6696\u6280\u672f\u95e8<\/span><span class=\"lmnt-card-d\">\u5730\u6696\u9009\u578b\u3001\u4ef7\u683c\u3001\u65bd\u5de5\u3001\u552e\u540e\u7684\u54c1\u7c7b\u603b\u5165\u53e3<\/span><\/a><a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=16752\" target=\"_blank\"><span class=\"lmnt-card-t\">\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d\uff1a\u4e24\u8054\u4f9b\u5206\u518c<\/span><span class=\"lmnt-card-d\">\u6237\u5f0f\u6c34\u673a\u3001\u6c1f\u673a\u3001\u58c1\u6302\u7089\u4e09\u79cd\u70ed\u6e90\u642d\u914d\u600e\u4e48\u9009<\/span><\/a><\/div>\n<section class=\"lmnt-sec\" id=\"yinyan\">\n<h2>\u5730\u6696\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\uff08\u4f1f\u661f\u7b2c\u4e09\u65b9\u76d1\u7406\uff09<\/h2>\n<p>\u56de\u586b\u524d\u7531\u4f1f\u661f\u7b2c\u4e09\u65b9\u76d1\u7406\u9a8c\u6536\uff1a0.8MPa \u4fdd\u538b\u3001\u9632\u4f2a\u7f16\u7801\u6838\u9a8c\u3001VR \u5168\u666f\u5f52\u6863\u3001\u53d1\u653e\u8d28\u4fdd\u5361\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" class=\"lmnt-fit\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/35DNYBGCYS.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5730\u6696\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\" loading=\"lazy\"><figcaption><b>35 \u00b7 \u5730\u6696\u9690\u853d\u5de5\u7a0b\u9a8c\u6536<\/b><br \/>\u5730\u6696\u9690\u853d\u9a8c\u6536\u7531\u4f1f\u661f\u7b2c\u4e09\u65b9\u76d1\u7406\u5b9e\u65bd\uff1a0.8MPa \u4fdd\u538b 30 \u5206\u949f\uff0c\u538b\u529b\u7a33\u5b9a\u65e0\u6e17\u6f0f\u3002<br \/>\u67e5\u9a8c\u5730\u6696\u7ba1\u9053\u9632\u4f2a\u7f16\u7801\u786e\u8ba4\u4f1f\u661f\u6b63\u54c1\uff1b\u9010\u9879\u6838\u5bf9\u76d8\u7ba1\u95f4\u8ddd\u3001\u5f2f\u66f2\u534a\u5f84\u3001\u4f38\u7f29\u7f1d\u3001\u8fb9\u754c\u4fdd\u6e29\u6761\u3001\u5206\u96c6\u6c34\u5668\u4e0e\u56fe\u7eb8\u4e00\u81f4\u3002<br \/>\u9a8c\u6536\u5408\u683c\u505a 360\u00b0 VR \u5168\u666f\u62cd\u6444\u5f52\u6863\uff0c\u767b\u8bb0\u4e1a\u4e3b\u4fe1\u606f\u53d1\u4f1f\u661f\u8d28\u4fdd\u5361\uff0c\u51ed\u624b\u673a\u53f7\u53ef\u5728\u4f1f\u661f\u5b98\u7f51\u6216\u516c\u4f17\u53f7\u67e5\u8d28\u4fdd\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"huitian\">\n<h2>\u6df7\u51dd\u571f\u56de\u586b\u4e0e\u6210\u54c1\u4fdd\u62a4<\/h2>\n<p>C15 \u8c46\u77f3\u6df7\u51dd\u571f\u6309 1:2:3 \u56de\u586b\uff0c\u5168\u7a0b\u5e26\u538b\u3001\u4eba\u5de5\u627e\u5e73\uff0c3 \u65e5\u517b\u62a4\u671f\u5185\u7981\u6b62\u78be\u538b\u6253\u9489\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/36HNTHT.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u6df7\u51dd\u571f\u56de\u586b\" loading=\"lazy\"><figcaption><b>36 \u00b7 \u6df7\u51dd\u571f\u56de\u586b<\/b><br \/>\u586b\u5145\u5c42\u7528\u4e0d\u4f4e\u4e8e C15 \u7684\u788e\u77f3\uff08\u8c46\u77f3\uff09\u6df7\u51dd\u571f\uff0c\u6c34\u6ce5:\u7802:\u77f3\u5b50=1:2:3\uff0c\u539a\u5ea6 30\uff5e40mm\uff1b\u77f3\u5b50\u7c92\u5f84 5\uff5e12mm \u65e0\u5c16\u9510\u68f1\u89d2\u3002<br \/>\u56de\u586b\u8fc7\u7a0b\u4e2d\u52a0\u70ed\u7ba1\u5185\u4fdd\u538b\u4e0d\u4f4e\u4e8e 0.6MPa\uff1b\u4e25\u7981\u673a\u68b0\u632f\u6363\uff0c\u4eba\u5458\u7a7f\u8f6f\u5e95\u978b\u3001\u4ece\u623f\u95f4\u6700\u5185\u4fa7\u5411\u95e8\u53e3\u5012\u9000\u65bd\u5de5\u3002<br \/>\u52a0\u94fa\u9632\u88c2\u7f51\uff1b\u56de\u586b\u5b8c\u5de5 3 \u65e5\u540e\u65b9\u53ef\u8fdb\u573a\uff0c3 \u65e5\u5185\u53ca\u540e\u7eed\u65bd\u5de5\u671f\u95f4\u7981\u6253\u9489\u6253\u5b54\u91cd\u51fb\u78be\u538b\uff0c\u7ba1\u9053\u4fdd\u6301\u5e26\u538b\u4fbf\u4e8e\u76d1\u6d4b\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"fengkou\">\n<h2>\u98ce\u53e3\u6d4b\u91cf\u4e0e\u98ce\u53e3\u5b89\u88c5<\/h2>\n<p>\u88c5\u4fee\u57fa\u672c\u5b8c\u5de5\u540e\u5b9e\u6d4b\u5f00\u5b54\u5c3a\u5bf8\u5de5\u5382\u5b9a\u5236\uff0c\u8f6f\u8fde\u63a5\u5c55\u5f00\u56fa\u5b9a\uff0c\u98ce\u53e3\u6a2a\u5e73\u7ad6\u76f4\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/37CLCFKHFKSJKKCC.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u6d4b\u91cf\u51fa\u98ce\u53e3\u56de\u98ce\u53e3\u5b9e\u9645\u5f00\u53e3\u5c3a\u5bf8\" loading=\"lazy\"><figcaption><b>37 \u00b7 \u6d4b\u91cf\u51fa\u98ce\u53e3\u56de\u98ce\u53e3\u5b9e\u9645\u5f00\u53e3\u5c3a\u5bf8<\/b><br \/>\u540a\u9876\u3001\u5899\u9762\u3001\u67dc\u4f53\u88c5\u4fee\u57fa\u672c\u5b8c\u5de5\u540e\uff0c\u5230\u73b0\u573a\u5b9e\u6d4b\u51fa\u98ce\u53e3\u3001\u56de\u98ce\u53e3\u5b9e\u9645\u5f00\u5b54\u5c3a\u5bf8\uff0c\u63d0\u4ea4\u5de5\u5382\u5b9a\u5236\u3002\u56de\u98ce\u53e3\u7684\u4f4d\u7f6e\u8981\u517c\u4f5c\u68c0\u4fee\u53e3\uff0c\u53e3\u5b50\u5f97\u591f\u4e00\u53ea\u624b\u4f38\u8fdb\u53bb\u62c6\u6ee4\u7f51\u3001\u6362\u7535\u673a\u2014\u2014\u7559\u4e0d\u591f\uff0c\u4ee5\u540e\u6d17\u6ee4\u7f51\u5c31\u5f97\u62c6\u540a\u9876\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/38FKAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u98ce\u53e3\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>38 \u00b7 \u98ce\u53e3\u5b89\u88c5<\/b><br \/>\u5b89\u88c5\u524d\u628a\u98ce\u53e3\u4e0a\u65b9\u8f6f\u8fde\u63a5\u5145\u5206\u5c55\u5f00\uff0c\u5e73\u6574\u56fa\u5b9a\u5230\u5f00\u5b54\u56db\u5468\uff0c\u8fde\u63a5\u4e25\u5bc6\u65e0\u8936\u76b1\u4e0d\u6f0f\u98ce\u3002<br \/>\u98ce\u53e3\u6a2a\u5e73\u7ad6\u76f4\u3001\u8868\u9762\u5e73\u6574\uff1b\u8fb9\u6846\u4e0e\u88c5\u9970\u9762\u8d34\u5b9e\u65e0\u7f1d\u9699\uff0c\u540c\u623f\u95f4\u9ad8\u5ea6\u4e00\u81f4\u3001\u6392\u5217\u6574\u9f50\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"kongzhi\">\n<h2>\u6e29\u63a7\u9762\u677f\u5b89\u88c5<\/h2>\n<p>\u7535\u5b50\u6267\u884c\u5668\u4e0e\u6e29\u63a7\u9762\u677f\u6309\u56de\u8def\u6807\u8bc6\u65ad\u7535\u63a5\u7ebf\uff0c\u901a\u7535\u6d4b\u8bd5\u5404\u623f\u95f4\u63a7\u5236\u6b63\u5e38\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/39WKMBAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u6e29\u63a7\u9762\u677f\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>39 \u00b7 \u6e29\u63a7\u9762\u677f\u5b89\u88c5<\/b><br \/>\u7535\u5b50\u6267\u884c\u5668\u88c5\u5728\u5206\u96c6\u6c34\u5668\u5bf9\u5e94\u56de\u8def\u4e0a\uff0c\u5361\u6263\u5230\u4f4d\u3001\u56de\u8def\u6807\u8bc6\u6e05\u6670\u3002<br \/>\u6e29\u63a7\u9762\u677f\u88c5\u5728\u9884\u7559\u5e95\u76d2\u5185\uff0c\u7aef\u6b63\u7262\u56fa\uff1b\u65ad\u7535\u6309\u5404\u623f\u95f4\u6807\u8bc6\u63a5\u7ebf\uff0c\u4e0d\u5f97\u9519\u63a5\u3002<br \/>\u88c5\u5b8c\u901a\u7535\u6d4b\u8bd5\uff0c\u786e\u8ba4\u5404\u623f\u95f4\u7ebf\u63a7\u5668\u901a\u8baf\u6b63\u5e38\u3001\u63a7\u5236\u6709\u6548\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"gaiban\">\n<h2>\u5206\u6c34\u7bb1\u76d6\u677f\u5b89\u88c5<\/h2>\n<p>\u6e05\u7406\u6838\u5bf9\u540e\u5c01\u76d6\uff0c\u65b9\u6b63\u6c34\u5e73\u3001\u542f\u95ed\u7075\u6d3b\uff0c\u6536\u53e3\u4e25\u5bc6\u7f8e\u89c2\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/40FSXGBAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5206\u6c34\u7bb1\u76d6\u677f\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>40 \u00b7 \u5206\u6c34\u7bb1\u76d6\u677f\u5b89\u88c5<\/b><br \/>\u76d6\u677f\u5b89\u88c5\u524d\u6e05\u7406\u7bb1\u5185\u6742\u7269\u7070\u5c18\uff0c\u6838\u5bf9\u5404\u56de\u8def\u3001\u6e29\u63a7\u7ebf\u3001\u7535\u5b50\u6267\u884c\u5668\u6807\u8bc6\u9f50\u5168\u6e05\u6670\u3002<br \/>\u76d6\u677f\u65b9\u6b63\u6c34\u5e73\u7262\u56fa\uff0c\u4e0e\u5899\u9762\u6536\u53e3\u4e25\u5bc6\uff1b\u542f\u95ed\u7075\u6d3b\uff0c\u4e0d\u4f5c\u4e3a\u627f\u91cd\u652f\u6491\u4f7f\u7528\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"fushu\">\n<h2>\u9644\u5c5e\u8bbe\u5907\u5b89\u88c5<\/h2>\n<p>\u6c34\u6cf5\u3001\u7f13\u51b2\u6c34\u7bb1\u3001\u81a8\u80c0\u7f50\u3001\u5b89\u5168\u9600\u3001\u538b\u529b\u8868\u3001\u538b\u5dee\u65c1\u901a\u9600\u3001\u8865\u6c34\u9600\u3001\u8fc7\u6ee4\u5668\u3001\u8f6f\u63a5\u7ba1\u3001\u6237\u5916\u4fdd\u62a4\uff0c\u6c34\u7cfb\u7edf\u7684\u5341\u4ef6\u914d\u5957\u4e00\u6b21\u88c5\u9f50\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/41SBAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u6c34\u6cf5\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>41 \u00b7 \u6c34\u6cf5\u5b89\u88c5<\/b><br \/>\u4e00\u6b21\u6cf5\u88c5\u5728\u56de\u6c34\u4fa7\uff0c\u4e8c\u6b21\u6cf5\u88c5\u5728\u4f9b\u6c34\u4fa7\uff1b\u5c4f\u853d\u6cf5\u6cf5\u8f74\u4fdd\u6301\u6c34\u5e73\uff0c\u5141\u8bb8\u89d2\u5ea6 \u00b15\u00b0\u3002<br \/>\u6c34\u6cf5\u626c\u7a0b\u6309\u6700\u4e0d\u5229\u73af\u8def\u538b\u635f\u6821\u6838\uff1b\u51b7\u51dd\u6c34\u69fd\u5782\u76f4\u671d\u4e0b\u4e0d\u88ab\u5835\u585e\uff0c\u6cf5\u4f53\u7528\u4fdd\u6e29\u68c9\u5305\u88f9\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/42HCSXAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7f13\u51b2\u6c34\u7bb1\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>42 \u00b7 \u7f13\u51b2\u6c34\u7bb1\u5b89\u88c5<\/b><br \/>\u7f13\u51b2\u6c34\u7bb1\u589e\u52a0\u7cfb\u7edf\u6c34\u5bb9\u91cf\uff1a\u4e3b\u673a\u5c11\u9891\u7e41\u542f\u505c\u66f4\u7701\u7535\u3001\u51ac\u5b63\u5316\u971c\u5feb\u70ed\u91cf\u635f\u8017\u5c0f\u3001\u6392\u6c14\u987a\u7545\u7cfb\u7edf\u7a33\u5b9a\u3001\u5e95\u90e8\u6392\u6c61\u9600\u9632\u6c34\u6cf5\u5438\u6742\u8d28\u3002<br \/>\u5bb9\u79ef\u6309\u5236\u51b7\u91cf 3\uff5e5L\/kW \u8ba1\u7b97\u9009\u578b\uff0c\u63a5\u53e3\u4e0e\u7ba1\u8def\u8bbe\u8ba1\u7ba1\u5f84\u4e00\u81f4\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/43PZGAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u81a8\u80c0\u7f50\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>43 \u00b7 \u81a8\u80c0\u7f50\u5b89\u88c5<\/b><br \/>\u81a8\u80c0\u7f50\u88c5\u5728\u6c34\u6cf5\u5438\u5165\u7ba1\u6bb5\uff0c\u8fde\u63a5\u7ba1\u4fdd\u6301\u5e38\u901a\u6c34\uff1b\u8c03\u8282\u6c34\u4f53\u79ef\u968f\u6e29\u5ea6\u80c0\u7f29\uff0c\u517c\u8d77\u5b9a\u538b\u4f5c\u7528\u3002<br \/>\u9884\u5145\u538b\u529b\u6bcf 1\uff5e2 \u5e74\u68c0\u6d4b\u4e00\u6b21\uff0c\u538b\u529b\u504f\u4f4e\u65f6\u8865\u6c14\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/44AQFAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5b89\u5168\u9600\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>44 \u00b7 \u5b89\u5168\u9600\u5b89\u88c5<\/b><br \/>\u5b89\u5168\u9600\u88c5\u5728\u56de\u6c34\u7ba1\u4e0a\u3001\u9760\u8fd1\u81a8\u80c0\u7f50\uff0c\u53ef\u6c34\u5e73\u6216\u5782\u76f4\u5b89\u88c5\uff0c\u4e0d\u53ef\u5012\u7f6e\u3002<br \/>\u6cc4\u538b\u503c\u53d6\u7cfb\u7edf\u6b63\u5e38\u5de5\u4f5c\u538b\u529b\u7684 1.5\uff5e2 \u500d\uff08\u6237\u5f0f\u7cfb\u7edf\u901a\u5e38\u53d6 3\uff5e5bar\uff09\uff0c\u4e14\u4e0d\u5f97\u5927\u4e8e\u81a8\u80c0\u7f50\u6700\u5927\u627f\u538b\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/45YLBAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u538b\u529b\u8868\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>45 \u00b7 \u538b\u529b\u8868\u5b89\u88c5<\/b><br \/>\u4e3b\u673a\u8fdb\u51fa\u6c34\u7ba1\u90fd\u88c5\u538b\u529b\u8868\uff0c\u65b9\u4fbf\u8c03\u8bd5\u4e0e\u552e\u540e\u67e5\u6545\u969c\uff1b\u91cf\u7a0b\u9009 0\uff5e0.6MPa \u6216 0\uff5e1MPa\uff0c\u4e0d\u9508\u94a2\u8010\u9707\u5145\u6cb9\u8868\u3002<br \/>\u5c0f\u7cfb\u7edf\u53ef\u7528\u6e29\u5ea6\u538b\u529b\u4e00\u4f53\u8868\uff0c\u7b80\u5316\u5b89\u88c5\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/46YCPTFAZ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u538b\u5dee\u65c1\u901a\u9600\u5b89\u88c5\" loading=\"lazy\"><figcaption><b>46 \u00b7 \u538b\u5dee\u65c1\u901a\u9600\u5b89\u88c5<\/b><br \/>\u538b\u5dee\u65c1\u901a\u9600\u88c5\u5728\u56de\u6c34\u7ba1\u8def\u4e0a\uff1a\u672b\u7aef\u7528\u91cf\u51cf\u5c11\u65f6\u81ea\u52a8\u65c1\u901a\u90e8\u5206\u6c34\u6d41\uff0c\u4fdd\u4f4f\u4e3b\u673a\u6700\u5c0f\u6c34\u6d41\u91cf\uff0c\u9632\u9ad8\u538b\u3001\u9632\u6c34\u6d41\u6545\u969c\u62a5\u8b66\u3001\u964d\u566a\u97f3\u3002<br \/>\u8c03\u8282\u65b9\u6cd5\uff1a\u5148\u5168\u5173\u672b\u7aef\u4e8c\u901a\u9600\u4e0e\u4e3b\u673a\u7403\u9600\u3001\u65c1\u901a\u9600\u5168\u5f00\uff0c\u5f00\u673a\u540e\u7f13\u6162\u5173\u5c0f\uff0c\u62a5\u6c34\u6d41\u6545\u969c\u65f6\u56de\u677e\u6d88\u8b66\uff1b\u4e34\u754c\u503c\u57fa\u7840\u4e0a\u518d\u677e\u4e00\u523b\u5ea6\uff0c\u517c\u987e\u5236\u51b7\u5236\u70ed\u4e24\u79cd\u6a21\u5f0f\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/47AZZDBSF.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5b89\u88c5\u81ea\u52a8\u8865\u6c34\u9600\" loading=\"lazy\"><figcaption><b>47 \u00b7 \u5b89\u88c5\u81ea\u52a8\u8865\u6c34\u9600<\/b><br \/>\u81ea\u52a8\u8865\u6c34\u9600\u88c5\u5728\u56de\u6c34\u7ba1\u6c34\u6cf5\u56de\u6c34\u4fa7\uff1b\u51fa\u6c34\u538b\u529b\u8bbe\u5b9a\u9ad8\u4e8e\u7cfb\u7edf\u9759\u538b 0.3bar\uff08\u516c\u5bd3\u4e00\u822c 1\uff5e1.5bar\uff0c\u522b\u5885 1.5\uff5e2bar\uff09\u3002<br \/>\u5165\u53e3\u5fc5\u987b\u8bbe\u6b62\u56de\u9600\u9632\u56de\u6d41\uff0c\u4fdd\u62a4\u81ea\u6765\u6c34\u6c34\u8d28\uff1b\u914d\u7403\u9600\u53ef\u624b\u52a8\u5207\u65ad\uff1b\u52a0\u9632\u51bb\u6db2\u7684\u7cfb\u7edf\u4e25\u7981\u76f4\u901a\u81ea\u6765\u6c34\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/48AZYXGLQ.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5b89\u88c5Y\u578b\u8fc7\u6ee4\u5668\" loading=\"lazy\"><figcaption><b>48 \u00b7 \u5b89\u88c5Y\u578b\u8fc7\u6ee4\u5668<\/b><br \/>\u4e3b\u673a\u8fdb\u6c34\u524d\u5fc5\u987b\u88c5 Y \u578b\u8fc7\u6ee4\u5668\uff0c\u9009\u578b\u4e0e\u8fdb\u53e3\u7ba1\u5f84\u4e00\u81f4\u3001\u76ee\u6570 40 \u76ee\u3002<br \/>\u6e05\u6d17\u53e3\u671d\u4e0b\u5b89\u88c5\uff0c\u4e0d\u5f97\u671d\u4e0a\uff1b\u6309\u5f53\u5730\u6c34\u8d28\u5b9a\u6e05\u6d17\u5468\u671f\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/49SWJAZRJG.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u5ba4\u5916\u673a\u5b89\u88c5\u8f6f\u63a5\u7ba1\" loading=\"lazy\"><figcaption><b>49 \u00b7 \u5ba4\u5916\u673a\u5b89\u88c5\u8f6f\u63a5\u7ba1<\/b><br \/>\u4e3b\u673a\u8fdb\u51fa\u6c34\u63a5\u53e3\u5904\u88c5\u8f6f\u8fde\u63a5\uff1a\u5185\u90e8\u80f6\u57ab\u7ec6\u5fc3\u5bf9\u51c6\u9632\u6f0f\u6c34\uff1b\u53ef\u7a0d\u5fae\u9519\u4f4d\u4f46\u4e0d\u5f97\u6253\u5f2f\uff0c\u6253\u5f2f\u5c31\u5931\u53bb\u51cf\u632f\u4f5c\u7528\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/50HWGDYPVCTGBH.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u6237\u5916\u7ba1\u9053\u7528PVC\u5957\u7ba1\u4fdd\u62a4\" loading=\"lazy\"><figcaption><b>50 \u00b7 \u6237\u5916\u7ba1\u9053\u7528PVC\u5957\u7ba1\u4fdd\u62a4<\/b><br \/>\u6237\u5916\u7ba1\u9053\u4fdd\u6e29\u5c42\u5916\u52a0\u786c\u8d28\u4fdd\u62a4\u58f3\uff0c\u8010\u53d7\u7d2b\u5916\u7ebf\u4e0d\u8001\u5316\uff1b\u4e0d\u7528\u5305\u624e\u5e26\u3002<br \/>\u7a7f\u5c4b\u9876\u53ca\u6237\u5916\u6bb5\u7ba1\u9053\u5957\u5165 PVC \u5957\u7ba1\u6577\u8bbe\u4fdd\u62a4\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"tiaoshi\">\n<h2>\u8c03\u8bd5\u8fd0\u8f6c\u4e0e\u7528\u6237\u4ea4\u4ed8<\/h2>\n<p>\u5f00\u673a\u8fd0\u884c\u4e0d\u5c11\u4e8e 2 \u5c0f\u65f6\u9010\u9879\u70b9\u68c0\uff0c\u518d\u5411\u4e1a\u4e3b\u505a\u64cd\u4f5c\u57f9\u8bad\u4ea4\u4ed8\u3002<\/p>\n<div class=\"lmnt-steps\">\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/51CSDSYX.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u53c2\u6570\u8c03\u8bd5\u8fd0\u884c\" loading=\"lazy\"><figcaption><b>51 \u00b7 \u53c2\u6570\u8c03\u8bd5\u8fd0\u884c<\/b><br \/>\u7531\u4e13\u4e1a\u8c03\u8bd5\u4eba\u5458\u5f00\u673a\uff0c\u8fd0\u884c\u4e0d\u5c11\u4e8e 2 \u5c0f\u65f6\uff1b\u901a\u8fc7\u7ebf\u63a7\u5668\u70b9\u68c0\u529f\u80fd\u76d1\u89c6\u5404\u4f20\u611f\u5668\u6570\u636e\u72b6\u6001\u3002<br \/>\u68c0\u67e5\u9879\u76ee\uff1a\u6c34\u6cf5\u8fd0\u8f6c\u3001\u5185\u5916\u673a\u8054\u52a8\u3001\u538b\u7f29\u673a\u58f0\u97f3\u3001\u98ce\u6247\u8f6c\u5411\u3001\u8fdb\u51fa\u6c34\u6e29\u5ea6\u3001\u5236\u51b7\u5242\u5404\u70b9\u6e29\u5ea6\u3001\u5916\u673a\u73af\u5883\u6e29\u5ea6\u3001\u8f93\u5165\u7535\u6d41\u4e0e\u529f\u7387\u3002<\/figcaption><\/figure>\n<figure class=\"lmnt-step\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/52YHJFZD.jpg\" alt=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u73b0\u573a\u5b9e\u62cd\uff1a\u7528\u6237\u4ea4\u4ed8\u6307\u5bfc\" loading=\"lazy\"><figcaption><b>52 \u00b7 \u7528\u6237\u4ea4\u4ed8\u6307\u5bfc<\/b><br \/>\u7531\u4e13\u4e1a\u8c03\u8bd5\u4eba\u5458\u5411\u4e1a\u4e3b\u505a\u64cd\u4f5c\u4e0e\u6ce8\u610f\u4e8b\u9879\u57f9\u8bad\uff1a\u4ea7\u54c1\u4f7f\u7528\u65b9\u6cd5\u3001APP\u3001\u7ebf\u63a7\u5668\u4e8c\u7ef4\u7801\u3001\u4fdd\u4fee\u7535\u8bdd\u4e0e\u4fdd\u4fee\u671f\u3001\u4fdd\u517b\u5e38\u8bc6\u3001\u516c\u4f17\u53f7\u3002<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<section class=\"lmnt-sec\" id=\"lengmei\">\n<h2>R32 \u51b7\u5a92\uff1a\u8fd9 52 \u6b65\u91cc\u4e3a\u4ec0\u4e48\u6ca1\u6709\u52a0\u6c1f\u8fd9\u4e00\u6b65<\/h2>\n<p>\u6709\u4eba\u62ff\u7740\u522b\u5bb6\u7684\u65bd\u5de5\u5355\u6765\u95ee\uff1a\u4f60\u4eec\u8fd9 52 \u6b65\u91cc\uff0c\u600e\u4e48\u6ca1\u6709\u710a\u94dc\u7ba1\u3001\u62bd\u771f\u7a7a\u3001\u52a0\u51b7\u5a92\uff1f\u4e0d\u662f\u6f0f\u5199\u4e86\uff0c\u662f\u4e24\u5957\u7cfb\u7edf\u4e0d\u4e00\u6837\u3002<\/p>\n<p>\u8fd9\u4e00\u9875\u8bb2\u7684\u662f\u6c34\u673a\u4e24\u8054\u4f9b\u3002\u5c4b\u91cc\u8d70\u7684\u662f\u6c34\u7ba1\uff0c\u63a5\u7684\u662f\u5206\u96c6\u6c34\u5668\u3001\u6c34\u6cf5\u548c\u5404\u4e2a\u623f\u95f4\u672b\u7aef\u3002\u51b7\u5a92\u53ea\u5728\u5ba4\u5916\u673a\u5230\u6c34\u6a21\u5757\u90a3\u4e00\u6bb5\u91cc\uff0c\u8fd9\u4e00\u6bb5\u5728\u51fa\u5382\u524d\u7531\u5382\u5bb6\u5c01\u597d\u3001\u5145\u597d\u3001\u9a8c\u8fc7\uff1b\u6709\u5916\u7f6e\u6c34\u6a21\u5757\u7684\u673a\u578b\uff0c\u73b0\u573a\u7531\u5382\u5bb6\u6309\u6280\u672f\u6587\u4ef6\u63a5\u597d\u5e76\u7559\u4e0b\u8bb0\u5f55\u3002\u73b0\u573a\u8fd9 52 \u6b65\u505a\u7684\u662f\u6c34\u7cfb\u7edf\uff0c\u6240\u4ee5\u6ca1\u6709\u52a0\u6c1f\uff0c\u4e5f\u6ca1\u6709\u73b0\u573a\u5145\u6ce8\u51b7\u5a92\u3002<\/p>\n<p>\u4ec0\u4e48\u65f6\u5019\u73b0\u573a\u624d\u4f1a\u78b0\u51b7\u5a92\uff1f\u88c5\u7684\u662f\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\uff08\u4e00\u62d6\u591a\u7684\u591a\u8054\u673a\uff0c\u5ba4\u5185\u673a\u76f4\u63a5\u8d70\u94dc\u7ba1\uff09\uff0c\u6216\u8005\u662f\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u5e26\u5730\u6696\u6a21\u5757\u90a3\u4e00\u7c7b\u3002\u90a3\u65f6\u624d\u8981\u73b0\u573a\u710a\u94dc\u7ba1\u3001\u5145\u6c2e\u4fdd\u62a4\u3001\u4fdd\u538b\u3001\u62bd\u771f\u7a7a\u3001\u6309\u673a\u578b\u5145\u6ce8\u51b7\u5a92\u3002<a href=\"https:\/\/longmai-nt.com\/?page_id=19171\">2026 \u5e74 11 \u6708 1 \u65e5\u5b9e\u65bd\u7684 GB\/T 27941-2026<\/a> \u7ba1\u7684\u5c31\u662f\u8fd9\u4e00\u7c7b\u7cfb\u7edf\u7684\u8bbe\u8ba1\u3001\u5b89\u88c5\u3001\u8c03\u8bd5\u548c\u9a8c\u6536\uff1b\u5b83\u662f\u63a8\u8350\u6027\u56fd\u5bb6\u6807\u51c6\uff0c\u4e0d\u662f\u5f3a\u5236\u6807\u51c6\uff0c\u6c34\u673a\u4e24\u8054\u4f9b\u7684\u6c34\u7cfb\u7edf\u65bd\u5de5\u4e0d\u6309\u5b83\u5224\u3002<\/p>\n<h3>\u5982\u679c\u5bb6\u91cc\u90a3\u53f0\u662f R32 \u673a\u578b\uff0c\u73b0\u573a\u4f1a\u591a\u51fa\u8fd9\u4e94\u4ef6\u4e8b<\/h3>\n<p><b>\u4e00\u3001\u5148\u5206\u6e05\u51b7\u5a92\u3002<\/b>R32 \u662f\u5f31\u53ef\u71c3\u51b7\u5a92\uff0c\u548c R410A \u4e0d\u662f\u4e00\u56de\u4e8b\uff0c\u5de5\u5177\u3001\u51b7\u5a92\u7f50\u8981\u5206\u5f00\uff0c\u522b\u770b\u7740\u7f50\u5b50\u5c31\u5f80\u7cfb\u7edf\u4e0a\u63a5\u3002<\/p>\n<p><b>\u4e8c\u3001\u51b7\u5a92\u6309\u6db2\u6001\u5145\u6ce8\u3002<\/b>\u6807\u51c6 5.10.3 \u5199\u660e R32 \u6309\u6db2\u6001\u5145\u6ce8\uff0c\u4e0d\u6309\u8001\u4e60\u60ef\u7528\u6c14\u6001\u90a3\u5957\u505a\u6cd5\u3002<\/p>\n<p><b>\u4e09\u3001\u4fdd\u538b\u548c\u62bd\u771f\u7a7a\u8981\u7559\u4e0b\u6570\u5b57\u3002<\/b>\u6807\u51c6\u8868 13 \u7ed9 R32 \u4e0e R410A \u540c\u4e00\u6863\uff1a1.5\u30013.0\u30014.0MPa \u4e09\u6b65\u52a0\u538b\uff0c\u6700\u540e 4.0MPa \u653e\u6ee1 24 \u5c0f\u65f6\uff0c\u6263\u6389\u6e29\u5ea6\u5f71\u54cd\u540e\u538b\u964d\u4e0d\u8d85\u8fc7 0.02MPa\uff1b\u62bd\u771f\u7a7a\u5230\u7edd\u5bf9\u538b\u529b\u4f4e\u4e8e 1.3kPa\uff0c\u505c\u6cf5\u770b 30 \u5206\u949f\u4e0d\u56de\u5347\u3002\u8fd9\u4e9b\u6570\u5b57\u662f\u6807\u51c6\u7ed9\u6c1f\u7cfb\u7edf\u591a\u8054\u673a\u7684\u505a\u6cd5\uff0c\u73b0\u573a\u4ee5\u8be5\u673a\u578b\u5382\u5bb6\u6280\u672f\u6587\u4ef6\u548c\u4ea4\u4ed8\u8bb0\u5f55\u4e3a\u51c6\u3002<\/p>\n<p><b>\u56db\u3001\u94dc\u7ba1\u58c1\u539a\u90a3\u4e00\u683c\u8fd8\u6ca1\u6709\u5b9a\u6570\u3002<\/b>\u6807\u51c6\u5f81\u6c42\u610f\u89c1\u7a3f\u8868 7 \u91cc\uff0cR32 \u5bf9\u5e94\u7684\u94dc\u7ba1\u58c1\u539a\u4e24\u683c\u662f\u5360\u4f4d\u7b26\uff0c\u6ca1\u6709\u6570\u503c\u3002\u73b0\u9636\u6bb5\u6309\u65e5\u7acb\u5382\u5bb6\u5de5\u827a\u89c4\u8303\u6267\u884c\uff0c\u7b49\u51fa\u7248\u793e\u6b63\u5f0f\u6587\u672c\u51fa\u6765\u518d\u6838\u8fd9\u4e00\u683c\u3002<\/p>\n<p><b>\u4e94\u3001\u8c03\u8bd5\u8bb0\u5f55\u8981\u5982\u5b9e\u5199\u3002<\/b>\u8c03\u8bd5\u6570\u636e\u8868\u52fe\u4e0a R32\uff0c\u8ffd\u52a0\u4e86\u591a\u5c11\u51b7\u5a92\u5199\u6e05\u695a\uff0c\u4e0d\u8981\u53ea\u5199\"\u5df2\u52a0\u6c1f\"\u4e09\u4e2a\u5b57\u3002<\/p>\n<h3>\u9a8c\u6536\u65f6\u95ee\u4e09\u53e5\u8bdd\u5c31\u591f<\/h3>\n<p>\u8fd9\u53f0\u5ba4\u5916\u673a\u7528\u7684\u662f\u54ea\u4e00\u79cd\u51b7\u5a92\uff1f\u73b0\u573a\u6709\u6ca1\u6709\u52a8\u8fc7\u51b7\u5a92\u7ba1\uff0c\u710a\u8fc7\u51e0\u5904\u3001\u6709\u6ca1\u6709\u8ffd\u52a0\u51b7\u5a92\uff1f\u4fdd\u538b\u3001\u62bd\u771f\u7a7a\u548c\u8c03\u8bd5\u7684\u8bb0\u5f55\u80fd\u4e0d\u80fd\u770b\u4e00\u773c\uff1f<\/p>\n<p>\u8fd9\u4e09\u4e2a\u95ee\u9898\uff0c\u6bd4\u95ee\"\u52a0\u4e86\u51e0\u516c\u65a4\u6c1f\"\u66f4\u80fd\u770b\u51fa\u6d3b\u505a\u5f97\u7ec6\u4e0d\u7ec6\u3002\u5199\u5728\u8bb0\u5f55\u4e0a\u7684\u624d\u7b97\u6570\uff0c\u53e3\u5934\u8bf4\u505a\u8fc7\u4e86\u4e0d\u7b97\u3002<\/p>\n<p>\u62ff\u4e0d\u51c6\u81ea\u5bb6\u662f\u54ea\u4e00\u5957\u7cfb\u7edf\uff0c\u628a\u65b9\u6848\u91cc\u7684\u5ba4\u5916\u673a\u578b\u53f7\u53d1\u7ed9\u6211\u4eec\uff0c\u7167\u578b\u53f7\u67e5\u4e00\u904d\u6bd4\u81ea\u5df1\u731c\u5feb\u3002<a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b\u7cfb\u7edf\u600e\u4e48\u5206<\/a>\uff5c<a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009<\/a><\/p>\n<\/section>\n<h2 id=\"jinchang-paixu\">\u4e09\u8d9f\u8fdb\u573a\uff0c\u8ddf\u88c5\u4fee\u600e\u4e48\u6392<\/h2>\n<div class=\"lmnt-sec\">\n<p>\u8fd9 14 \u4e2a\u9636\u6bb5\u4e0d\u662f\u4e00\u53e3\u6c14\u505a\u5b8c\u7684\u3002\u5b83\u8ddf\u7740\u4f60\u5bb6\u88c5\u4fee\uff0c\u5206\u4e09\u8d9f\u8fdb\u573a\uff0c\u6bcf\u4e00\u8d9f\u90fd\u5361\u5728\u88c5\u4fee\u7684\u4e00\u4e2a\u8282\u70b9\u4e0a\u3002\u77e5\u9053\u8fd9\u4e09\u8d9f\uff0c\u4f60\u5c31\u77e5\u9053\u4ec0\u4e48\u65f6\u5019\u8be5\u50ac\u3001\u4ec0\u4e48\u65f6\u5019\u50ac\u4e5f\u6ca1\u7528\u3002<\/p>\n<div class=\"lmnt-trip\">\n<div class=\"lmnt-trip-item\">\n<span class=\"lmnt-trip-n\">\u7b2c\u4e00\u8d9f<\/span><\/p>\n<h3>\u5b9a\u4f4d\uff0c\u5230\u7a7a\u8c03\u9690\u853d\u9a8c\u6536<\/h3>\n<p><b>\u4ec0\u4e48\u65f6\u5019\u6765\uff1a<\/b>\u5f00\u5de5\u524d\u540e\uff0c\u6c34\u7535\u8fdb\u573a\u90a3\u4e2a\u9636\u6bb5\u3002<br \/><b>\u5361\u5728\u54ea\u4e2a\u8282\u70b9\uff1a<\/b>\u5c01\u540a\u9876\u4e4b\u524d\u5fc5\u987b\u9a8c\u6536\u5b8c\u3002\u9a8c\u6536\u5355\u6ca1\u62ff\u5230\u624b\uff0c\u522b\u8ba9\u6728\u5de5\u5c01\u677f\u2014\u2014\u5c01\u4e0a\u53bb\u5c31\u518d\u4e5f\u770b\u4e0d\u89c1\u4e86\u3002<br \/><b>\u4f60\u8be5\u95ee\u7684\uff1a<\/b>\u6211\u5bb6\u8fd9\u5957\u6c34\u8def\uff0c\u4ece\u5b9a\u4f4d\u5230\u9690\u853d\u9a8c\u6536\uff0c\u4f60\u4eec\u6392\u51e0\u5929\uff1f<\/p>\n<\/div>\n<div class=\"lmnt-trip-item\">\n<span class=\"lmnt-trip-n\">\u7b2c\u4e8c\u8d9f<\/span><\/p>\n<h3>\u5730\u6696\u94fa\u7ba1\uff0c\u5230\u56de\u586b<\/h3>\n<p><b>\u4ec0\u4e48\u65f6\u5019\u6765\uff1a<\/b>\u5730\u9762\u627e\u5e73\u5b8c\u3001\u74e6\u5de5\u8fdb\u573a\u524d\u3002<br \/><b>\u5361\u5728\u54ea\u4e2a\u8282\u70b9\uff1a<\/b>\u56de\u586b\u5b8c 3 \u65e5\u5185\u4e0d\u80fd\u4e0a\u4eba\u3001\u4e0d\u80fd\u5806\u6599\u3001\u4e0d\u80fd\u6253\u9489\u3002\u8fd9\u4e09\u5929\u5f97\u7ed9\u5b83\u7a7a\u51fa\u6765\uff0c\u4e0d\u7136\u7816\u4e00\u538b\u5c31\u4f24\u4e86\u7ba1\u5b50\u3002<br \/><b>\u4f60\u8be5\u95ee\u7684\uff1a<\/b>\u56de\u586b\u5b8c\u90a3\u4e00\u5929\u7b97\u8d77\uff0c\u4f60\u4eec\u8981\u6c42\u51e0\u5929\u4e0d\u4e0a\u4eba\uff1f<\/p>\n<\/div>\n<div class=\"lmnt-trip-item\">\n<span class=\"lmnt-trip-n\">\u7b2c\u4e09\u8d9f<\/span><\/p>\n<h3>\u88c5\u98ce\u53e3\u3001\u8c03\u8bd5\u3001\u4ea4\u4ed8<\/h3>\n<p><b>\u4ec0\u4e48\u65f6\u5019\u6765\uff1a<\/b>\u540a\u9876\u3001\u5899\u9762\u3001\u67dc\u4f53\u57fa\u672c\u505a\u5b8c\u4ee5\u540e\u3002<br \/><b>\u5361\u5728\u54ea\u4e2a\u8282\u70b9\uff1a<\/b>\u98ce\u53e3\u662f\u6309\u5b9e\u6d4b\u5f00\u5b54\u5c3a\u5bf8\u56de\u5de5\u5382\u5b9a\u5236\u7684\uff0c\u6765\u5f97\u665a\uff0c\u4f46\u5fc5\u987b\u8d76\u5728\u5bb6\u5177\u8fdb\u573a\u524d\u88c5\u5b8c\u3002<br \/><b>\u4f60\u8be5\u95ee\u7684\uff1a<\/b>\u98ce\u53e3\u5b9a\u5236\u8981\u51e0\u5929\uff0c\u80fd\u8d76\u5728\u6211\u5bb6\u5bb6\u5177\u8fdb\u573a\u524d\u88c5\u5b8c\u5417\uff1f<\/p>\n<\/div>\n<\/div>\n<p class=\"lmnt-note\">\u5177\u4f53\u5929\u6570\u6309\u4f60\u5bb6\u9762\u79ef\u3001\u6237\u578b\u548c\u88c5\u4fee\u8fdb\u5ea6\u5b9a\uff0c\u8fd9\u9875\u4e0d\u7ed9\u7edf\u4e00\u6570\u5b57\u2014\u2014\u7ed9\u4e86\u4f60\u4e5f\u7528\u4e0d\u4e0a\u3002\u91cf\u623f\u65f6\u4f1a\u7ed9\u4f60\u4e00\u5f20\u6392\u671f\u8868\uff0c\u5199\u6e05\u6bcf\u4e00\u8d9f\u54ea\u5929\u8fdb\u573a\u3001\u54ea\u5929\u5fc5\u987b\u505a\u5b8c\u3002<\/p>\n<\/div>\n<h2 id=\"duizhao\">\u5230\u73b0\u573a\uff0c\u770b\u8fd9\u516d\u5904<\/h2>\n<div class=\"lmnt-sec\">\n<p>52 \u9053\u5de5\u5e8f\u4f60\u4e0d\u53ef\u80fd\u6837\u6837\u76ef\u3002\u771f\u6b63\u51b3\u5b9a\u8fd9\u5957\u7cfb\u7edf\u597d\u4e0d\u597d\u7528\u7684\uff0c\u662f\u4e0b\u9762\u516d\u4e2a\u65f6\u95f4\u70b9\u3002\u6bcf\u4e00\u5904\u90fd\u5199\u7740\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\u3002\u6253\u5370\u51fa\u6765\u5e26\u8fdb\u5de5\u5730\uff0c\u5bf9\u4e00\u5904\u5212\u4e00\u5904\u3002<\/p>\n<table class=\"lmnt-check\">\n<thead>\n<tr>\n<th>\u4ec0\u4e48\u65f6\u5019<\/th>\n<th>\u4f60\u770b\u4ec0\u4e48<\/th>\n<th>\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837<\/th>\n<th>\u8981\u4ec0\u4e48\u51ed\u8bc1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-k=\"\u4ec0\u4e48\u65f6\u5019\">\u5b9a\u4f4d\u5f53\u5929<\/td>\n<td data-k=\"\u4f60\u770b\u4ec0\u4e48\">\u5185\u673a\u5b9a\u5728\u54ea\u4e2a\u623f\u95f4\u3001\u4ec0\u4e48\u4f4d\u7f6e\uff1b\u5916\u673a\u79bb\u5367\u5ba4\u7a97\u591a\u8fdc\uff1b\u6e29\u63a7\u5668\u79bb\u5730\u591a\u9ad8\uff1b\u5206\u6c34\u7bb1\u5728\u54ea<\/td>\n<td data-k=\"\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\">\u5185\u673a\u6b63\u5728\u5e8a\u5934\u4e0a\u65b9\uff1b\u5916\u673a\u8d34\u7740\u5367\u5ba4\u6216\u4e66\u623f\u7684\u7a97\uff1b\u5206\u6c34\u7bb1\u88c5\u5728\u6253\u4e0d\u5f00\u3001\u4e0d\u597d\u68c0\u4fee\u7684\u5730\u65b9<\/td>\n<td data-k=\"\u8981\u4ec0\u4e48\u51ed\u8bc1\">\u6bcf\u4e2a\u70b9\u4f4d\u7684\u5b9a\u4f4d\u7167\u7247<\/td>\n<\/tr>\n<tr>\n<td>\u5185\u673a\u540a\u88c5\u5b8c<\/td>\n<td>\u540a\u6746\u662f\u4e0d\u662f M8 \u4ee5\u4e0a\u3001\u56db\u6839\u9f50\u4e0d\u9f50\uff1b\u6709\u6ca1\u6709\u53cc\u87ba\u6bcd\uff1b\u540a\u6746\u4e0b\u9762\u6709\u6ca1\u6709\u51cf\u9707\u57ab\uff1b\u8d85\u8fc7 1.5m \u6709\u6ca1\u6709\u52a0\u659c\u6491<\/td>\n<td>\u540a\u6746\u76f4\u63a5\u786c\u63a5\u697c\u677f\u3001\u6ca1\u51cf\u9707\u57ab\uff1b\u7528\u624b\u63a8\u4e00\u4e0b\u4f1a\u6643\uff1b\u51fa\u56de\u98ce\u53e3\u6ca1\u505a\u9632\u5c18\u4fdd\u62a4<\/td>\n<td>\u540a\u88c5\u7167\u7247<\/td>\n<\/tr>\n<tr>\n<td><b>\u5c01\u540a\u9876\u524d<\/b><br \/><span class=\"lmnt-tag\">\u6700\u8981\u7d27<\/span><\/td>\n<td>\u538b\u529b\u8868\u8bfb\u6570\u7a33\u4e0d\u7a33\uff1b\u4fdd\u6e29\u6709\u6ca1\u6709\u88f8\u7ba1\uff1b\u51b7\u51dd\u6c34\u5761\u5ea6\u591f\u4e0d\u591f\uff1b\u9690\u853d\u9a8c\u6536\u5355\u586b\u4e86\u6ca1\u6709<\/td>\n<td>\u538b\u529b\u5f80\u4e0b\u6389\uff1b\u4fdd\u6e29\u6709\u88f8\u9732\u7ba1\u6bb5\uff1b\u9a8c\u6536\u5355\u8fd8\u6ca1\u62ff\u5230\uff0c\u6728\u5de5\u5c31\u8981\u5c01\u677f<\/td>\n<td><b>\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355<\/b><\/td>\n<\/tr>\n<tr>\n<td>\u5730\u6696\u56de\u586b\u524d<\/td>\n<td>\u76d8\u7ba1\u95f4\u8ddd\u5300\u4e0d\u5300\uff1b\u4f38\u7f29\u7f1d\u6709\u6ca1\u6709\uff1b\u5206\u96c6\u6c34\u5668\u6bcf\u8def\u80fd\u4e0d\u80fd\u5355\u72ec\u5173\uff1b\u4f1f\u661f\u7684\u4eba\u6765\u8fc7\u6ca1\u6709<\/td>\n<td>\u4e0d\u5e26\u538b\u5c31\u56de\u586b\uff1b\u7ba1\u9053\u6ca1\u6709\u9632\u4f2a\u7f16\u7801\u53ef\u67e5\uff1b\u6ca1\u505a VR \u5168\u666f<\/td>\n<td>\u4f1f\u661f\u9a8c\u6536\u5355 \uff0b VR \u5168\u666f \uff0b \u8d28\u4fdd\u5361<\/td>\n<\/tr>\n<tr>\n<td>\u56de\u586b\u5b8c<\/td>\n<td>\u6709\u6ca1\u6709\u88c2\u7f1d\uff1b3 \u5929\u5185\u6709\u6ca1\u6709\u4eba\u4e0a\u53bb\u5806\u6599\u6253\u9489\uff1b\u7ba1\u9053\u8fd8\u5e26\u7740\u538b\u6ca1\u6709<\/td>\n<td>\u56de\u586b\u7b2c\u4e8c\u5929\u5c31\u4e0a\u4eba\u642c\u7816\uff1b\u538b\u529b\u8868\u5df2\u7ecf\u62c6\u4e86<\/td>\n<td>\u4fdd\u538b\u8bb0\u5f55\uff08\u56de\u586b\u524d\u540e\u5404\u4e00\u6b21\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u8c03\u8bd5\u4ea4\u4ed8<\/td>\n<td>\u6bcf\u4e2a\u623f\u95f4\u80fd\u4e0d\u80fd\u5355\u72ec\u8c03\u6e29\uff1b\u98ce\u76d8\u58f0\u97f3\u5927\u4e0d\u5927\uff1b\u6709\u6ca1\u6709\u4eba\u6559\u4f60\u600e\u4e48\u7528<\/td>\n<td>\u53ea\u5f00\u673a\u8bd5\u4e00\u4e0b\u5c31\u8d70\u4e86\uff1b\u6ca1\u7ed9\u4fdd\u4fee\u7535\u8bdd\u548c\u4fdd\u517b\u8bf4\u660e<\/td>\n<td>\u8fd0\u884c\u8bb0\u5f55 \uff0b \u8d28\u4fdd\u5361 \uff0b \u64cd\u4f5c\u57f9\u8bad<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"lmnt-note\">\u8fd9\u5f20\u8868\u5bf9\u5e94\u6b63\u6587\u7b2c 01\u300109\u300118\u300120\u300124\u300125\u300134\u300135\u300136\u300137\u300151\u300152 \u6b65\u3002\u54ea\u4e00\u5904\u5bf9\u4e0d\u4e0a\uff0c\u7ffb\u56de\u90a3\u4e00\u6b65\u770b\u539f\u6587\uff0c\u6807\u51c6\u6570\u5b57\u90fd\u5199\u5728\u91cc\u9762\u3002<\/p>\n<\/div>\n<h2 id=\"faq\">\u5e38\u89c1\u95ee\u9898<\/h2>\n<div class=\"lmnt-sec\">\n<details class=\"lmnt-qa\" open>\n<summary>\u88c5\u4e00\u5957\u8981\u591a\u4e45\uff1f\u4f1a\u4e0d\u4f1a\u62d6\u6211\u88c5\u4fee\uff1f<\/summary>\n<div>\u8fd9\u6d3b\u4e0d\u662f\u8fde\u7740\u505a\u5b8c\u7684\uff0c\u8ddf\u7740\u88c5\u4fee\u5206\u4e09\u8d9f\u8fdb\u573a\u3002\u7b2c\u4e00\u8d9f\u4ece\u5b9a\u4f4d\u5230\u7a7a\u8c03\u9690\u853d\u9a8c\u6536\uff0c\u5c01\u540a\u9876\u524d\u5fc5\u987b\u5b8c\uff1b\u7b2c\u4e8c\u8d9f\u5730\u6696\u4ece\u6750\u6599\u9a8c\u6536\u5230\u56de\u586b\uff0c\u74e6\u5de5\u8fdb\u573a\u524d\u5fc5\u987b\u5b8c\uff0c\u56de\u586b\u540e 3 \u65e5\u5185\u4e0d\u80fd\u4e0a\u4eba\u5806\u6599\uff1b\u7b2c\u4e09\u8d9f\u88c5\u98ce\u53e3\u3001\u6e29\u63a7\u3001\u9644\u5c5e\u8bbe\u5907\u5e76\u8c03\u8bd5\uff0c\u7b49\u540a\u9876\u5899\u9762\u67dc\u4f53\u57fa\u672c\u505a\u5b8c\u624d\u6765\u3002\u5177\u4f53\u51e0\u5929\u770b\u4f60\u5bb6\u9762\u79ef\u548c\u6237\u578b\uff0c\u91cf\u623f\u65f6\u8ba9\u65bd\u5de5\u65b9\u7ed9\u6392\u671f\u8868\u3002\u95ee\u7684\u65f6\u5019\u522b\u95ee\"\u5927\u6982\u591a\u4e45\"\uff0c\u95ee\"\u6211\u5bb6\u8fd9\u5957\u4ece\u5b9a\u4f4d\u5230\u9690\u853d\u9a8c\u6536\u6392\u51e0\u5929\"\u3002<\/div>\n<\/details>\n<details class=\"lmnt-qa\" open>\n<summary>\u6211\u5728\u73b0\u573a\u8be5\u76ef\u54ea\u51e0\u6b65\uff1f<\/summary>\n<div>\u516d\u5904\uff1a\u5b9a\u4f4d\u5f53\u5929\u3001\u5185\u673a\u540a\u88c5\u5b8c\u3001\u5c01\u540a\u9876\u524d\u3001\u5730\u6696\u56de\u586b\u524d\u3001\u56de\u586b\u5b8c\u3001\u8c03\u8bd5\u4ea4\u4ed8\u3002\u6700\u8981\u7d27\u7684\u662f\u5c01\u540a\u9876\u524d\u90a3\u4e00\u6b21\u2014\u2014\u7ba1\u8def\u4e00\u5c01\u5c31\u518d\u4e5f\u770b\u4e0d\u89c1\u4e86\u3002\u90a3\u4e00\u5904\u770b\u4e09\u6837\uff1a\u538b\u529b\u8868\u8bfb\u6570\u8fd8\u7a33\u4e0d\u7a33\u3001\u4fdd\u6e29\u6709\u6ca1\u6709\u88f8\u7ba1\u3001\u9690\u853d\u9a8c\u6536\u5355\u586b\u4e86\u6ca1\u6709\u3002\u4e0a\u9762\u6709\u4e00\u5f20\u516d\u884c\u7684\u5bf9\u7167\u8868\uff0c\u6253\u5370\u4e0b\u6765\u5e26\u8fdb\u5de5\u5730\uff0c\u5bf9\u4e00\u5904\u5212\u4e00\u5904\u3002<\/div>\n<\/details>\n<details class=\"lmnt-qa\" open>\n<summary>\u600e\u4e48\u786e\u8ba4\u7ba1\u8def\u4e0d\u6f0f\uff1f<\/summary>\n<div>\u770b\u538b\u529b\u8868\uff0c\u800c\u4e14\u8981\u8bb0\u5f55\uff0c\u4e0d\u80fd\u53ea\u542c\u4e00\u53e5\"\u8bd5\u8fc7\u4e86\"\u3002\u7a7a\u8c03\u6c34\u7cfb\u7edf\u5728\u70ed\u7194\u8fde\u63a5\u5b8c\u6210 24 \u5c0f\u65f6\u540e\u8bd5\u538b\uff1a\u8bd5\u9a8c\u538b\u529b\u4e3a\u5de5\u4f5c\u538b\u529b 1.5 \u500d\u4e14\u4e0d\u5c0f\u4e8e 0.6MPa\uff0c\u5347\u538b\u4e0d\u5c11\u4e8e 10 \u5206\u949f\uff1b\u7a33\u538b 1 \u5c0f\u65f6\uff0c\u538b\u964d\u4e0d\u8d85\u8fc7 0.05MPa\uff1b\u518d\u964d\u5230 1.15 \u500d\u5de5\u4f5c\u538b\u529b\u7a33\u538b 2 \u5c0f\u65f6\uff0c\u538b\u964d\u4e0d\u8d85\u8fc7 0.03MPa\uff0c\u5404\u8fde\u63a5\u5904\u65e0\u6e17\u6f0f\u3002\u4f60\u8981\u505a\u7684\u662f\uff1a\u8ba9\u65bd\u5de5\u65b9\u628a\u4e24\u6b21\u7a33\u538b\u7684\u8d77\u59cb\u8bfb\u6570\u548c\u7ed3\u675f\u8bfb\u6570\u90fd\u5199\u4e0b\u6765\uff0c\u7b7e\u5b57\u3002<\/div>\n<\/details>\n<details class=\"lmnt-qa\" open>\n<summary>\u540a\u9876\u4f1a\u4e0d\u4f1a\u88ab\u6ce1\uff1f<\/summary>\n<div>\u4f1a\uff0c\u6709\u4e24\u6761\u8def\uff0c\u90fd\u5f97\u5835\u4f4f\u3002\u7b2c\u4e00\u6761\u662f\u51b7\u51dd\u6c34\uff1a\u6392\u6c34\u7ba1\u8d85\u8fc7 3 \u7c73\u8981\u52a0\u6392\u6c14\u5b54\uff0c\u4e0d\u7136\u79ef\u6c14\u5f62\u6210\u6c14\u5835\uff0c\u6c34\u6392\u4e0d\u51fa\u53bb\u4f1a\u6ea2\u51fa\uff1b\u6cc4\u6c34\u652f\u7ba1\u5761\u5ea6\u4e0d\u5c0f\u4e8e 1%\u3001\u6c34\u5e73\u5e72\u7ba1\u4e0d\u5c0f\u4e8e 0.5%\uff1b\u5168\u90e8\u88c5\u5b8c\u505a\u704c\u6c34\u6392\u6c34\u8bd5\u9a8c\u3002\u540a\u9876\u91cc\u6ca1\u7a7a\u95f4\u505a\u8db3\u5761\u5ea6\u65f6\uff0c\u5185\u673a\u8981\u5e26\u63d0\u5347\u6cf5\uff0c\u5148\u628a\u6c34\u62bd\u4e0a\u53bb\u518d\u8d70\u5761\u2014\u2014\u6ca1\u6709\u6cf5\u53c8\u505a\u4e0d\u51fa\u5761\u5ea6\uff0c\u6c34\u5c31\u79ef\u5728\u51dd\u6c34\u76d8\u91cc\u3002\u7b2c\u4e8c\u6761\u662f\u4fdd\u6e29\uff1a\u4f9b\u6c34\u7ba1\u4fdd\u6e29\u4e0d\u5c0f\u4e8e 20mm\u3001\u51b7\u51dd\u6c34\u7ba1\u4e0d\u5c0f\u4e8e 9mm\uff0c\u63a5\u53e3\u6d82\u80f6\u7c98\u4e25\uff0c\u7a7f\u5899\u7a7f\u697c\u677f\u4e0d\u80fd\u65ad\u3002\u6709\u88f8\u7ba1\u6216\u8005\u63a5\u53e3\u6ca1\u7c98\u4e25\uff0c\u590f\u5929\u7ba1\u58c1\u7ed3\u9732\uff0c\u6c34\u987a\u7740\u4fdd\u6e29\u5c42\u5f80\u4e0b\u6ef4\u3002<\/div>\n<\/details>\n<details class=\"lmnt-qa\" open>\n<summary>\u90a3\u4e9b\u770b\u4e0d\u89c1\u7684\u914d\u4ef6\uff0c\u4f1a\u4e0d\u4f1a\u88ab\u7701\u6389\uff1f<\/summary>\n<div>\u8fd9\u662f\u6700\u5bb9\u6613\u7701\u7684\u5730\u65b9\uff0c\u4e5f\u662f\u6c34\u673a\u597d\u4e0d\u597d\u7528\u7684\u5173\u952e\u3002\u7b2c 41 \u5230 48 \u6b65\u8fd9\u516b\u4ef6\u8981\u4e00\u6b21\u88c5\u9f50\uff1a\u6c34\u6cf5\uff08\u4e00\u6b21\u6cf5\u5728\u56de\u6c34\u4fa7\u3001\u4e8c\u6b21\u6cf5\u5728\u4f9b\u6c34\u4fa7\uff09\u3001\u7f13\u51b2\u6c34\u7bb1\u3001\u81a8\u80c0\u7f50\u3001\u5b89\u5168\u9600\u3001\u538b\u529b\u8868\uff08\u8fdb\u51fa\u6c34\u90fd\u88c5\uff09\u3001\u538b\u5dee\u65c1\u901a\u9600\u3001\u81ea\u52a8\u8865\u6c34\u9600\u3001Y \u578b\u8fc7\u6ee4\u5668\uff0840 \u76ee\u3001\u6e05\u6d17\u53e3\u671d\u4e0b\uff09\u3002\u7f13\u51b2\u6c34\u7bb1\u6309\u5236\u51b7\u91cf 3\uff5e5L\/kW \u9009\uff0c\u4f5c\u7528\u662f\u8ba9\u4e3b\u673a\u5c11\u9891\u7e41\u542f\u505c\u3001\u51ac\u5929\u5316\u971c\u5feb\u3001\u7cfb\u7edf\u7a33\u5b9a\u3002\u770b\u62a5\u4ef7\u5355\u7684\u65f6\u5019\uff0c\u8fd9\u51e0\u4ef6\u8981\u9010\u9879\u5199\u7740\u54c1\u724c\u548c\u89c4\u683c\u2014\u2014\u53ea\u5199\u4e3b\u673a\u578b\u53f7\u7684\u62a5\u4ef7\u5355\uff0c\u7b49\u4e8e\u8fd9\u51e0\u4ef6\u6ca1\u7b97\u8fdb\u53bb\u3002<\/div>\n<\/details>\n<details class=\"lmnt-qa\" open>\n<summary>\u9690\u853d\u4e4b\u540e\u51fa\u4e86\u95ee\u9898\uff0c\u51ed\u4ec0\u4e48\u8bf4\u6e05\u8d23\u4efb\uff1f<\/summary>\n<div>\u9760\u4e09\u6837\u4e1c\u897f\uff0c\u90fd\u662f\u7ed9\u4f60\u7684\uff0c\u4e0d\u662f\u7ed9\u516c\u53f8\u7684\u3002\u7b2c\u4e00\uff0c\u7a7a\u8c03\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u5355\uff1a\u9690\u853d\u524d\u7531\u76d1\u7406\u9010\u9879\u9a8c\u6536\u5185\u5916\u673a\u56fa\u5b9a\u4e0e\u6c34\u5e73\u3001\u7ba1\u5f84\u8d70\u5411\u3001\u70ed\u7194\u8d28\u91cf\u3001\u652f\u540a\u67b6\u95f4\u8ddd\u3001\u51b7\u51dd\u6c34\u5761\u5ea6\u3001\u4fdd\u6e29\u539a\u5ea6\u3001\u9600\u95e8\u65b9\u5411\u3001\u8bd5\u538b\u8bb0\u5f55\uff0c\u586b\u5355\u5b58\u6863\uff0c\u5408\u683c\u624d\u5141\u8bb8\u5c01\u540a\u9876\u3002\u7b2c\u4e8c\uff0c\u4f1f\u661f\u7b2c\u4e09\u65b9\u9a8c\u6536\uff1a\u5730\u6696\u56de\u586b\u524d\u7531\u4f1f\u661f\u7684\u4eba\u6765\u505a\uff0c0.8MPa \u4fdd\u538b 30 \u5206\u949f\uff0c\u67e5\u9a8c\u7ba1\u9053\u9632\u4f2a\u7f16\u7801\uff0c\u505a 360\u00b0 VR \u5168\u666f\u5f52\u6863\uff0c\u767b\u8bb0\u4f60\u7684\u4fe1\u606f\u53d1\u8d28\u4fdd\u5361\uff0c\u51ed\u624b\u673a\u53f7\u53ef\u5728\u4f1f\u661f\u5b98\u7f51\u6216\u516c\u4f17\u53f7\u67e5\u3002\u7b2c\u4e09\uff0cVR \u5168\u666f\uff1a\u4ee5\u540e\u8981\u5728\u5899\u4e0a\u6253\u5b54\u3001\u5730\u9762\u5f00\u69fd\uff0c\u5148\u8c03\u51fa\u6765\u770b\u4e00\u773c\u7ba1\u7ebf\u5728\u54ea\u3002<\/div>\n<\/details>\n<details class=\"lmnt-qa\" open>\n<summary>\u88c5\u5b8c\u600e\u4e48\u7b97\u4ea4\u4ed8\uff1f<\/summary>\n<div>\u4e0d\u662f\u5f00\u673a\u5c31\u8d70\u3002\u8c03\u8bd5\u7531\u4e13\u4e1a\u4eba\u5458\u5f00\u673a\uff0c\u8fd0\u884c\u4e0d\u5c11\u4e8e 2 \u5c0f\u65f6\uff0c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u529f\u80fd\u770b\u6c34\u6cf5\u8fd0\u8f6c\u3001\u5185\u5916\u673a\u8054\u52a8\u3001\u538b\u7f29\u673a\u58f0\u97f3\u3001\u98ce\u6247\u8f6c\u5411\u3001\u8fdb\u51fa\u6c34\u6e29\u5ea6\u3001\u5916\u673a\u73af\u5883\u6e29\u5ea6\u3001\u8f93\u5165\u7535\u6d41\u4e0e\u529f\u7387\u3002\u7136\u540e\u5411\u4f60\u505a\u64cd\u4f5c\u57f9\u8bad\uff1a\u600e\u4e48\u7528\u3001APP \u600e\u4e48\u8fde\u3001\u7ebf\u63a7\u5668\u4e8c\u7ef4\u7801\u3001\u4fdd\u4fee\u7535\u8bdd\u548c\u4fdd\u4fee\u671f\u3001\u4fdd\u517b\u5e38\u8bc6\u3001\u516c\u4f17\u53f7\u3002\u8fd9\u51e0\u6837\u6ca1\u7ed9\uff0c\u4e0d\u7b97\u4ea4\u4ed8\u3002<\/div>\n<\/details>\n<\/div>\n<h2>\u88c5\u5b8c\u4e4b\u540e<\/h2>\n<div class=\"lmnt-sec\">\n<p>\u65bd\u5de5\u53ea\u662f\u7cfb\u7edf\u5bff\u547d\u7684\u4e00\u534a\uff0c\u53e6\u4e00\u534a\u5728\u9009\u578b\u4e0e\u552e\u540e\u3002\u5f80\u4e0b\u770b\uff1a<\/p>\n<div class=\"lmnt-links\">\n<a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\" target=\"_blank\"><span class=\"lmnt-card-t\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/span><span class=\"lmnt-card-d\">\u9009\u9505\u7089\u3001\u9009\u5957\u9910\u3001\u7b97\u4ef7\u683c\uff0c\u8f93\u5165\u9762\u79ef\u76f4\u63a5\u51fa\u4e09\u6863\u65b9\u6848<\/span><\/a><br \/>\n<a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=7418\" target=\"_blank\"><span class=\"lmnt-card-t\">\u4e94\u6052\u4ef7\u683c\u9875\u7cfb\u5217<\/span><span class=\"lmnt-card-d\">\u4e24\u8054\u4f9b\u4e94\u6052\u7cfb\u7edf\u7684\u4ef7\u683c\u6784\u6210\u4e0e\u533a\u95f4<\/span><\/a><br \/>\n<a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\" target=\"_blank\"><span class=\"lmnt-card-t\">\u9f99\u8109\u6696\u901a\u6848\u4f8b\u4e2d\u5fc3<\/span><span class=\"lmnt-card-d\">\u771f\u5b9e\u5ba2\u6237\u5bb6\u7684\u4e24\u8054\u4f9b\u4e0e\u4e2d\u592e\u7a7a\u8c03\u5b89\u88c5\u5b9e\u666f<\/span><\/a><br \/>\n<a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=4875\" target=\"_blank\"><span class=\"lmnt-card-t\">\u552e\u540e\u5b9e\u5f55\u5e74\u5ea6\u6848\u4f8b\u5408\u96c6<\/span><span class=\"lmnt-card-d\">\u88c5\u5b8c\u4e4b\u540e\u7528\u5f97\u600e\u4e48\u6837\uff0c\u770b\u771f\u5b9e\u552e\u540e\u8bb0\u5f55<\/span><\/a><br \/>\n<a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=625\" target=\"_blank\"><span class=\"lmnt-card-t\">\u670d\u52a1\u4fdd\u969c<\/span><span class=\"lmnt-card-d\">\u8d28\u4fdd\u5e74\u9650\u3001\u54cd\u5e94\u65f6\u6548\u4e0e\u552e\u540e\u627f\u8bfa<\/span><\/a><br \/>\n<a class=\"lmnt-card\" href=\"https:\/\/longmai-nt.com\/?page_id=3023\" target=\"_blank\"><span class=\"lmnt-card-t\">\u5b98\u7f51\u7ad9\u70b9\u5730\u56fe<\/span><span class=\"lmnt-card-d\">\u5168\u90e8\u77e5\u8bc6\u4f53\u7cfb\u9875\u9762\u5165\u53e3<\/span><\/a>\n<\/div>\n<\/div>\n<div class=\"lmnt-cta\">\n<h2>\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p>\u60f3\u6838\u5bf9\u81ea\u5bb6\u7684\u4e24\u8054\u4f9b\u5b89\u88c5\uff1f\u5e26\u4e0a\u8fd9\u4e00\u9875\u5230\u73b0\u573a\uff0c\u6216\u8005\u5e26\u4e0a\u4f60\u5bb6\u65b9\u6848\u6765\u95e8\u5e97\uff0c\u6211\u4eec\u9010\u9879\u5bf9\u7740 52 \u9053\u5de5\u5e8f\u8bb2\u3002<\/p>\n<div class=\"lmnt-stores\">\n<div class=\"lmnt-store\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u5357\u5bcc\u68ee\u65d7\u8230\u5e97\u5b9e\u666f\" loading=\"lazy\"><b>\u5357\u5bcc\u68ee\u65d7\u8230\u5e97<\/b><br \/>\u6210\u90fd\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348<br \/><a href=\"tel:02886131795\">028-86131795<\/a><\/div>\n<div class=\"lmnt-store\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986\u5b9e\u666f\" loading=\"lazy\"><b>\u5317\u5bcc\u68ee\u667a\u6167\u7a7a\u6c14\u9986<\/b><br \/>\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<br \/><a href=\"tel:02865272586\">028-65272586<\/a><\/div>\n<\/div>\n<p><a class=\"lmnt-btn\" href=\"https:\/\/longmai-nt.com\/?page_id=4556\">\u7b97\u4e00\u7b97\u4e24\u8054\u4f9b\u4ef7\u683c<\/a><br \/>\n<a class=\"lmnt-btn\" href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e86\u89e3\u4e24\u8054\u4f9b\u7cfb\u7edf<\/a>\n<\/div>\n<p class=\"lmnt-code\">\u9f99\u8109\u6696\u901a\uff08\u6210\u90fd\uff09\u00b7 2004 \u5e74\u8d77\u6df1\u8015\u6696\u901a \uff5c \u5de5\u827a\u6807\u51c6\u51fa\u5904\uff1a\u9f99\u8109\u6696\u901a\u300a\u6c34\u673a\u4e24\u8054\u4f9b\u7cfb\u7edf\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\u300b\u4f01\u4e1a\u6807\u51c6<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u65bd\u5de5\u5de5\u827a\u987552 \u9053\u5de5\u5e8f\u5b9e\u62cd\u6210\u90fd \u6c34\u673a\u4e24\u8054 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-18096","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u600e\u4e48\u88c5\u624d\u4e0d\u51fa\u95ee\u9898\u3002\u9f99\u8109\u6696\u901a\u628a 14 \u4e2a\u9636\u6bb5\u300152 \u9053\u5de5\u5e8f\u5168\u6d41\u7a0b\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5761\u5ea6\u3001\u538b\u529b\u3001\u95f4\u8ddd\u8fd9\u4e9b\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u3002\u53e6\u9644\u4e00\u5f20\u73b0\u573a\u5bf9\u7167\u8868\uff1a\u516d\u4e2a\u8282\u70b9\u5206\u522b\u5199\u6e05\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\uff0c\u53ef\u4ee5\u6253\u5370\u5e26\u8fdb\u5de5\u5730\u9010\u9879\u5bf9\u3002\u5148\u770b\u6d41\u7a0b\uff0c\u518d\u51b3\u5b9a\u627e\u8c01\u88c5\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=18096\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u600e\u4e48\u88c5\u624d\u4e0d\u51fa\u95ee\u9898\u3002\u9f99\u8109\u6696\u901a\u628a 14 \u4e2a\u9636\u6bb5\u300152 \u9053\u5de5\u5e8f\u5168\u6d41\u7a0b\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5761\u5ea6\u3001\u538b\u529b\u3001\u95f4\u8ddd\u8fd9\u4e9b\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u3002\u53e6\u9644\u4e00\u5f20\u73b0\u573a\u5bf9\u7167\u8868\uff1a\u516d\u4e2a\u8282\u70b9\u5206\u522b\u5199\u6e05\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\uff0c\u53ef\u4ee5\u6253\u5370\u5e26\u8fdb\u5de5\u5730\u9010\u9879\u5bf9\u3002\u5148\u770b\u6d41\u7a0b\uff0c\u518d\u51b3\u5b9a\u627e\u8c01\u88c5\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=18096\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T09:00:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/01QQDW.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"14 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096\",\"name\":\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/01QQDW.jpg\",\"datePublished\":\"2026-11-04T09:59:55+00:00\",\"dateModified\":\"2026-11-21T09:00:29+00:00\",\"description\":\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u600e\u4e48\u88c5\u624d\u4e0d\u51fa\u95ee\u9898\u3002\u9f99\u8109\u6696\u901a\u628a 14 \u4e2a\u9636\u6bb5\u300152 \u9053\u5de5\u5e8f\u5168\u6d41\u7a0b\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5761\u5ea6\u3001\u538b\u529b\u3001\u95f4\u8ddd\u8fd9\u4e9b\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u3002\u53e6\u9644\u4e00\u5f20\u73b0\u573a\u5bf9\u7167\u8868\uff1a\u516d\u4e2a\u8282\u70b9\u5206\u522b\u5199\u6e05\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\uff0c\u53ef\u4ee5\u6253\u5370\u5e26\u8fdb\u5de5\u5730\u9010\u9879\u5bf9\u3002\u5148\u770b\u6d41\u7a0b\uff0c\u518d\u51b3\u5b9a\u627e\u8c01\u88c5\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/01QQDW.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/01QQDW.jpg\",\"width\":1378,\"height\":775},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=18096#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8 - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u600e\u4e48\u88c5\u624d\u4e0d\u51fa\u95ee\u9898\u3002\u9f99\u8109\u6696\u901a\u628a 14 \u4e2a\u9636\u6bb5\u300152 \u9053\u5de5\u5e8f\u5168\u6d41\u7a0b\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5761\u5ea6\u3001\u538b\u529b\u3001\u95f4\u8ddd\u8fd9\u4e9b\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u3002\u53e6\u9644\u4e00\u5f20\u73b0\u573a\u5bf9\u7167\u8868\uff1a\u516d\u4e2a\u8282\u70b9\u5206\u522b\u5199\u6e05\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\uff0c\u53ef\u4ee5\u6253\u5370\u5e26\u8fdb\u5de5\u5730\u9010\u9879\u5bf9\u3002\u5148\u770b\u6d41\u7a0b\uff0c\u518d\u51b3\u5b9a\u627e\u8c01\u88c5\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=18096","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8 - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u600e\u4e48\u88c5\u624d\u4e0d\u51fa\u95ee\u9898\u3002\u9f99\u8109\u6696\u901a\u628a 14 \u4e2a\u9636\u6bb5\u300152 \u9053\u5de5\u5e8f\u5168\u6d41\u7a0b\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5761\u5ea6\u3001\u538b\u529b\u3001\u95f4\u8ddd\u8fd9\u4e9b\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u3002\u53e6\u9644\u4e00\u5f20\u73b0\u573a\u5bf9\u7167\u8868\uff1a\u516d\u4e2a\u8282\u70b9\u5206\u522b\u5199\u6e05\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\uff0c\u53ef\u4ee5\u6253\u5370\u5e26\u8fdb\u5de5\u5730\u9010\u9879\u5bf9\u3002\u5148\u770b\u6d41\u7a0b\uff0c\u518d\u51b3\u5b9a\u627e\u8c01\u88c5\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=18096","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-21T09:00:29+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/01QQDW.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"14 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=18096","url":"https:\/\/longmai-nt.com\/?page_id=18096","name":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=18096#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=18096#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/01QQDW.jpg","datePublished":"2026-11-04T09:59:55+00:00","dateModified":"2026-11-21T09:00:29+00:00","description":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u600e\u4e48\u88c5\u624d\u4e0d\u51fa\u95ee\u9898\u3002\u9f99\u8109\u6696\u901a\u628a 14 \u4e2a\u9636\u6bb5\u300152 \u9053\u5de5\u5e8f\u5168\u6d41\u7a0b\u5b9e\u62cd\u6446\u51fa\u6765\uff0c\u6bcf\u4e00\u6b65\u5199\u6e05\u5761\u5ea6\u3001\u538b\u529b\u3001\u95f4\u8ddd\u8fd9\u4e9b\u80fd\u6838\u5bf9\u7684\u6570\u5b57\u3002\u53e6\u9644\u4e00\u5f20\u73b0\u573a\u5bf9\u7167\u8868\uff1a\u516d\u4e2a\u8282\u70b9\u5206\u522b\u5199\u6e05\u770b\u4ec0\u4e48\u3001\u4e0d\u5408\u683c\u957f\u4ec0\u4e48\u6837\u3001\u8981\u4ec0\u4e48\u51ed\u8bc1\uff0c\u53ef\u4ee5\u6253\u5370\u5e26\u8fdb\u5de5\u5730\u9010\u9879\u5bf9\u3002\u5148\u770b\u6d41\u7a0b\uff0c\u518d\u51b3\u5b9a\u627e\u8c01\u88c5\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=18096#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=18096"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=18096#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/01QQDW.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/01QQDW.jpg","width":1378,"height":775},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=18096#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u6c34\u673a\u4e24\u8054\u4f9b\u65bd\u5de5\u5b89\u88c5\u5168\u6d41\u7a0b\uff1a52\u6b65\u5b9e\u62cd\uff0c\u4ece\u5b9a\u4f4d\u5230\u4ea4\u4ed8"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/18096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=18096"}],"version-history":[{"count":8,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/18096\/revisions"}],"predecessor-version":[{"id":21082,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/18096\/revisions\/21082"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=18096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}