{"id":1824,"date":"2026-05-28T20:06:18","date_gmt":"2026-05-28T12:06:18","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1824"},"modified":"2026-10-10T15:39:56","modified_gmt":"2026-10-10T07:39:56","slug":"%e8%8f%b2%e6%96%af%e6%9b%bc%e5%a3%81%e6%8c%82%e7%82%89-%e9%87%87%e6%9a%96%e7%b3%bb%e7%bb%9f%e8%af%a6%e6%83%85%e9%a1%b5","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1824","title":{"rendered":"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875"},"content":{"rendered":"\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading has-icon has-icon-right\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u76ee\u5f55<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n<div aria-labelledby=\"accordion-item-1\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ae0\u8282<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9\u6982\u8981<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm01\">\u7b2c\u4e00\u7ae0\uff1a\u5982\u679c\u4f60\u4e5f\u9047\u5230\u8fd9\u4e9b\u95ee\u9898<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5178\u578b\u56f0\u6270 \u00b7 \u4e24\u7528\u7089\u5148\u5929\u77db\u76fe \u00b7 \u4e09\u5927\u7834\u5c40\u8def\u7ebf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm02\">\u7b2c\u4e8c\u7ae0\uff1a\u91c7\u6696\u6280\u672f\u8fdb\u5316\u53f2<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53d1\u660e\u6545\u4e8b \u00b7 \u56db\u4ee3\u6f14\u8fdb \u00b7 \u672b\u7aef\u51b3\u5b9a\u9505\u7089\u547d\u8fd0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm03\">\u7b2c\u4e09\u7ae0\uff1a\u83f2\u65af\u66fc\u54c1\u724c\u4e0e\u4ea7\u54c1\u7ebf<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u767e\u5e74\u91cc\u7a0b\u7891 \u00b7 \u4ea7\u54c1\u7ebf\u5168\u666f \u00b7 300-W\u65d7\u8230 \u00b7 \u8fdb\u53e3vs\u56fd\u4ea7 \u00b7 \u578b\u53f7\u53c2\u6570<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm04\">\u7b2c\u56db\u7ae0\uff1a\u6838\u5fc3\u6280\u672f\u89e3\u6790<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u539f\u7406 \u00b7 \u5168\u9884\u6df7\u71c3\u70e7 \u00b7 \u4e0d\u9508\u94a2\u6362\u70ed\u5668 \u00b7 \u83f2\u65af\u66fc\u72ec\u6709\u6280\u672f \u00b7 \u4f4e\u6e29\u6696\u6c14\u7247\u5339\u914d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm0401\">\u7b2c\u56db\u7ae0\uff1a4.1 \u51b7\u51dd\u7089\u4e3a\u4ec0\u4e48\u7701\u6c14\uff1f<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\"><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm05\">\u7b2c\u4e94\u7ae0\uff1a\u9009\u578b\u6307\u5357<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u56db\u6b65\u9009\u578b\u6cd5 \u00b7 \u7ecf\u6d4e\u6027\u6d4b\u7b97 \u00b7 \u5357\u65b9\u91c7\u6696\u8d39\u7528\u53c2\u8003<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm06\">\u7b2c\u516d\u7ae0\uff1a\u771f\u5b9e\u53e3\u7891\u4e0e\u7ade\u54c1\u5bf9\u6bd4<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6b63\u9762\u8bc4\u4ef7 \u00b7 \u8d1f\u9762\u8bc4\u4ef7 \u00b7 \u7ecf\u9500\u5546\u89c6\u89d2 \u00b7 \u56db\u54c1\u724c\u6a2a\u8bc4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm07\">\u7b2c\u4e03\u7ae0\uff1a\u5b89\u88c5\u89c4\u8303\u4e0e\u4f7f\u7528\u6307\u5357<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u4f4d\u7f6e \u00b7 \u70df\u7ba1\u89c4\u8303 \u00b7 \u51b7\u51dd\u6c34\u6392\u653e \u00b7 \u56db\u5b63\u4f7f\u7528 \u00b7 \u6545\u969c\u4ee3\u7801 \u00b7 \u4fdd\u517b\u65e5\u5386<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#fsm08\">\u7b2c\u516b\u7ae0\uff1a\u5e38\u89c1\u95ee\u9898FAQ<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">8\u4e2a\u9ad8\u9891\u95ee\u7b54<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">1917\u5e74\uff0c\u5fb7\u56fd\u970d\u592b\uff0c\u7ea6\u7ff0\u00b7\u83f2\u65af\u66fc\u521b\u7acb\u4e86\u4e00\u5bb6\u4f9b\u70ed\u516c\u53f8\u3002<br>\u767e\u5e74\u540e\uff0c\u5b83\u7684\u51b7\u51dd\u6280\u672f\u6210\u4e3a\u6b27\u6d32\u91c7\u6696\u7684\u6807\u6746\u3002<br>\u4f46\u6211\u4eec\u4e0d\u53ea\u8bb2\u83f2\u65af\u66fc\u2014\u2014\u6211\u4eec\u66f4\u60f3\u8ba9\u4f60\u660e\u767d\uff1a<br><strong>\u51b7\u51dd\u9769\u547d\u4e0d\u662f\u67d0\u4e2a\u54c1\u724c\u7684\u8425\u9500\u8bdd\u672f\uff0c\u800c\u662f\u91c7\u6696\u884c\u4e1a\u4e0d\u53ef\u9006\u7684\u6280\u672f\u65b9\u5411\u3002<\/strong><br>\u6b27\u76df2015\u5e74\u5168\u9762\u7981\u552e\u975e\u51b7\u51dd\u9505\u7089\uff0c2025\u5e74\u51b7\u51dd\u7089\u5e02\u5360\u7387\u5df2\u8fbe95%\u3002<br>\u4e86\u89e3\u83f2\u65af\u66fc\uff0c\u4e5f\u662f\u5728\u4e86\u89e3\"\u4f60\u5bb6\u672a\u6765\u7684\u9505\u7089\u5e94\u8be5\u957f\u4ec0\u4e48\u6837\"\u3002<\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"fsm01\" class=\"wp-block-heading\">\u7b2c\u4e00\u7ae0\uff1a\u5982\u679c\u4f60\u4e5f\u9047\u5230\u8fd9\u4e9b\u95ee\u9898<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u5916\u7f51\u516c\u5f00\u8d44\u6599 + IMA\u77e5\u8bc6\u5e93\u00b7\u91c7\u6696\u6570\u636e\u6c47\u603b + \u9f99\u8109\u6696\u901a\u00b7\u6696\u901a\u7528\u6237\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">1.1 \u5178\u578b\u56f0\u6270<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e38\u89c1\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u771f\u5b9e\u5ba2\u6237\u53cd\u9988<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u95ee\u9898\u6839\u6e90<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u601d\u8def<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u8017\u9ad8\uff0c\u71c3\u6c14\u8d39\u8d85\u6807<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"80\u5e73\uff0c\u4e00\u67081000\u591a\u71c3\u6c14\u8d39\"\uff08\u58c1\u6302\u7089\u54c1\u724c\u7528\u6237\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u9505\u7089\u578b\u53f7\u8fc7\u5927\uff0c\u9891\u7e41\u542f\u505c 2.\u666e\u901a\u7089\u4f4e\u6e29\u8fd0\u884c\u6548\u7387\u4f4e<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u7cbe\u51c6\u70ed\u8d1f\u8377\u8ba1\u7b97\uff0c\u9009\u6700\u63a5\u8fd1\u7684\u578b\u53f7 2.\u51b7\u51dd\u7089+\u4f4e\u6e29\u672b\u7aef\u5339\u914d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6d17\u6fa1\u6c34\u5ffd\u51b7\u5ffd\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u4e24\u7528\u7089\u5c31\u662f\u9ebb\u70e6\uff0c\u6d17\u6fa1\u6c34\u6d17\u5230\u4e00\u534a\u5c31\u51c9\u4e86\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u4e24\u7528\u7089\u6700\u5c0f\u529f\u7387\u8fc7\u9ad8\uff0c\u590f\u5b63\u8d85\u6e29 2.\u751f\u6d3b\u70ed\u6c34\u4e0e\u91c7\u6696\u5171\u4eab\u70ed\u6e90<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u51b7\u51dd\u7089\u5bbd\u5e45\u53d8\u9891\uff08\u6700\u5c0f3.1kW\uff09 2.\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\u9891\u7e41\u542f\u505c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u9505\u7089\u4e00\u4f1a\u70e7\u4e00\u4f1a\u505c\uff0c\u665a\u4e0a\u66f4\u660e\u663e\uff0c\u6298\u817e\u4eba\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u6700\u5c0f\u8f93\u51fa\u8fdc\u5927\u4e8e\u6052\u6e29\u8d1f\u8377 2.\u65e0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u51b7\u51dd\u7089\u9996\u9009\uff08\u6700\u5c0f\u8f93\u51fa\u4f4e\u81f33kW\uff09 2.\u8054\u52a8\u6e29\u63a7\u5668\uff0c\u6e29\u5ea6\u8fbe\u6807\u5373\u505c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089\u566a\u97f3\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u58c1\u6302\u7089\u4e00\u542f\u52a8\uff0c\u58f0\u97f3\u50cf\u62d6\u62c9\u673a\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u98ce\u673a\/\u6c34\u6cf5\u8001\u5316 2.\u5b89\u88c5\u51cf\u9707\u4e0d\u5230\u4f4d<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.\u9009\u62e9\u4f4e\u566a\u97f3\u673a\u578b 2.\u4e13\u4e1a\u5b89\u88c5\u51cf\u9707\u63aa\u65bd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">1.2 \u4e24\u7528\u7089\u7684\"\u5148\u5929\u77db\u76fe\"<\/h3>\n\n<p class=\"wp-block-paragraph\">\u4e24\u7528\u7089\u81ea1967\u5e74\u8bde\u751f\u4ee5\u6765\uff0c\u4e00\u76f4\u5b58\u5728\u4e00\u4e2a\u7269\u7406\u77db\u76fe\uff1a<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u91c7\u6696\u8981\"\u5c0f\u706b\u6162\u7096\"\uff0c\u70ed\u6c34\u8981\"\u731b\u706b\u7206\u7092\"\u3002<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9700\u6c42\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7406\u60f3\u529f\u7387<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u5e94\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c3d\u91cf\u5c0f\uff082-4kW\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">120\u33a1\u4fdd\u6e29\u9636\u6bb5\u4ec5\u97003-5kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u751f\u6d3b\u70ed\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c3d\u91cf\u5927\uff0824-35kW+\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51ac\u5929\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u6d17\u6fa1\u970025-30kW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u4e00\u53f030kW\u7684\u7089\u5b50\uff0c\u6700\u5c0f\u529f\u7387\u53ea\u67098kW\uff08\u8c03\u8282\u6bd41:4\uff09\u2014\u2014\u91c7\u6696\u65f6\u5c31\u7b49\u4e8e\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\uff0c\u9891\u7e41\u542f\u505c\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u590f\u5929\u66f4\u5c34\u5c2c<\/strong>\uff1a\u8fdb\u6c34\u6e29\u5ea6\u5df2\u670925\u2103\uff0c\u53ea\u9700\u5347\u6e2915\u2103\u523040\u2103\uff0c\u4f46\u6700\u5c0f\u529f\u73878kW\u8fdc\u8d85\u9700\u6c42\uff0c\u5bfc\u81f4\"\u70b9\u706b\u2192\u8d85\u6e29\u2192\u7184\u706b\u2192\u518d\u70b9\u706b\"\u7684\u6b7b\u5faa\u73af\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">1.3 \u4e09\u5927\u7834\u5c40\u8def\u7ebf<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8def\u7ebf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u539f\u7406<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u8868\u4ea7\u54c1<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6548\u679c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u6bb5\u71c3\u70e7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u70e7\u5668\u5206\u591a\u6bb5\uff0c\u6309\u9700\u70b9\u71c3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6797\u5185\uff08\u56db\u6bb53.5kW\uff09\u3001\u7f8e\u7684\uff081:12\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6210\u672c\u4f4e\uff0c\u590f\u5929\u6c34\u6e29\u6ce2\u52a8\u00b11\u2103<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u53d8\u9891<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u7a7a\u6c14\u7cbe\u786e\u6df7\u5408\uff0c\u65e0\u7ea7\u8c03\u8282<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u83f2\u65af\u66fcB1JG\uff081:11\uff0c\u6700\u5c0f3.1kW\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696+\u70ed\u6c34\u77db\u76fe\u5927\u5e45\u7f13\u89e3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u70ed\u6c34\u5206\u79bb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u4e13\u505a\u91c7\u6696\uff0c\u53e6\u914d\u70ed\u6c34\u8bbe\u5907<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>Vitodens 333-F\uff08\u5185\u7f6e\u6c34\u7bb1\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f7b\u5e95\u89e3\u51b3\uff0c\u9002\u5408\u5927\u6237\u578b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1&nbsp;<strong>\u6211\u4eec\u7684\u5efa\u8bae<\/strong>\uff1a\u9884\u7b97\u6709\u9650\u2192\u83f2\u65af\u66fcB1JG\u51b7\u51dd\u4e24\u7528\u7089\uff08\u77db\u76fe\u5df2\u5927\u5e45\u7f13\u89e3\uff09\uff1b\u8ffd\u6c42\u6781\u81f4\u2192\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u3002<\/p>\n<\/blockquote>\n\n<h2 id=\"fsm02\" class=\"wp-block-heading\">\u7b2c\u4e8c\u7ae0\uff1a\u91c7\u6696\u6280\u672f\u8fdb\u5316\u53f2<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u9a6c\u7ef4\u65af\u00b7\u5916\u7f51\u8d44\u6599 + IMA\u77e5\u8bc6\u5e93\u00b7\u9f99\u8109\u6696\u901a\u7b2c\u4e94\u7bc7\/\u7b2c\u516d\u7bc7 + \u4e94\u6052\u207a\u7cfb\u7edf\u00b7\u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">2.1 \u58c1\u6302\u7089\u53d1\u660e\u6545\u4e8b\uff1a\u4ece\u53a8\u623f\u5230\u5168\u5c4b<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e74\u4efd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91cc\u7a0b\u7891<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u610f\u4e49<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1894\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u95ed\u5408\u5f0f\u70ed\u6c34\u5668\u53d1\u660e\uff08\u5a01\u80fd\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4eba\u7c7b\u7b2c\u4e00\u6b21\u628a\"\u70e7\u6c34\"\u642c\u8fdb\u5bc6\u95ed\u7cfb\u7edf\uff0c\u5b89\u5168\u6027\u548c\u6548\u7387\u8d28\u53d8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1904\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c\u4e00\u53f0\u58c1\u6302\u5f0f\u70ed\u6c34\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u70ed\u8bbe\u5907\u4ece\u5730\u4e0a\"\u6302\u5230\u4e86\u5899\u4e0a\"\uff0c\u7a7a\u95f4\u9769\u547d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1961\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c\u4e00\u53f0\u58c1\u6302\u5f0f\u71c3\u6c14\u9505\u7089\uff08Circo-Geyser\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u6237\u72ec\u7acb\u91c7\u6696\u65f6\u4ee3\u5f00\u5e55\u2014\u2014\"\u6e29\u6696\u4e0d\u518d\u662f\u6574\u680b\u697c\u7684\u4e8b\"<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1967\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c\u4e00\u53f0\u4e24\u7528\u7089\uff08Combi-Geyser\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u673a\u4e24\u7528\uff0c\u4f46\u4e5f\u57cb\u4e0b\"\u91c7\u6696\u8981\u5c0f\u706b\u3001\u70ed\u6c34\u8981\u5927\u706b\"\u7684\u5148\u5929\u77db\u76fe<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1979\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u6280\u672f\u4e13\u5229\u51fa\u73b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u6c14\u6c34\u84b8\u6c14\u51b7\u51dd\u56de\u6536\u6f5c\u70ed\uff0c\u70ed\u6548\u7387\u7a81\u7834100%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1995\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u5f00\u59cb\u5728\u6b27\u6d32\u666e\u53ca<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\u6210\u719f\uff0c\u6210\u672c\u4e0b\u964d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>2015\u5e74<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6b27\u76dfErP\u6307\u4ee4\u751f\u6548\uff0c\u7981\u6b62\u9500\u552e\u975e\u51b7\u51dd\u9505\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u6210\u4e3a\u6b27\u6d32\u552f\u4e00\u5408\u6cd5\u9009\u62e9<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2025\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6b27\u6d32\u51b7\u51dd\u7089\u5e02\u5360\u7387\u8fbe95%<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u56fd\u5e02\u573a\u6e17\u900f\u7387\u5feb\u901f\u63d0\u5347<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">2.2 \u58c1\u6302\u7089\u56db\u4ee3\u6f14\u8fdb<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u9645<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u8868\u6280\u672f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u7279\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bc4\u4ef7<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c1\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u5e38\u89c4\u7089\u00b7\u5927\u6c14\u5f0f\u71c3\u70e7<\/td><td class=\"has-text-align-left\" data-align=\"left\">1990s-2010s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u9891\uff0c\u9ad8\u6e29\u8fd0\u884c\uff0870-80\u2103\uff09\uff0c\u6548\u738785-90%\uff0c\u6700\u4f4e\u8f93\u51fa8-10kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u8017\u9ad8\uff0c\u4f4e\u6e29\u6548\u7387\u9aa4\u964d\u81f350-60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c2\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u6bb5\u71c3\u70e7\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">2015-2025<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u6e29\u6863+\u4f4e\u6e29\u6863\u4e24\u6863\u8c03\u8282<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u8981\u89e3\u51b3\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c3\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u00b7\u5168\u9884\u6df7<\/td><td class=\"has-text-align-left\" data-align=\"left\">2020s-\u81f3\u4eca<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53d8\u9891\uff0c\u4f4e\u6e29\u8fd0\u884c\uff0855\u2103\u4ee5\u4e0b\uff09\u6548\u7387105-110%\uff0c\u6700\u4f4e\u8f93\u51fa3-4kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u771f\u6b63\u8282\u80fd\uff0c\u5339\u914d\u5730\u6696\/\u4f4e\u6e29\u6696\u6c14\u7247\u7701\u6c1420-30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u672a\u6765<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u53d8\u9891+\u667a\u6167\u4e92\u8054<\/td><td class=\"has-text-align-left\" data-align=\"left\">2025+<\/td><td class=\"has-text-align-left\" data-align=\"left\">AI\u81ea\u52a8\u5339\u914d\u6700\u4f18\u8fd0\u884c\u7b56\u7565\uff0c\u591a\u80fd\u6e90\u8026\u5408<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089+\u70ed\u6cf5\u6df7\u52a8\u6210\u4e3a\u4e3b\u6d41<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">2.3 \u672b\u7aef\u51b3\u5b9a\u4e86\u9505\u7089\u7684\u547d\u8fd0<\/h3>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u5f88\u591a\u4eba\u5ffd\u7565\u7684\u5173\u952e\u4e8b\u5b9e\uff1a<strong>\u4e70\u4e86\u51b7\u51dd\u7089\uff0c\u4f46\u672b\u7aef\u4e0d\u5339\u914d\uff0c\u7b49\u4e8e\u767d\u4e70\u3002<\/strong><\/p>\n<\/blockquote>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90 \u00d7 \u672b\u7aef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c34\/\u56de\u6c34\u6e29\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7ed3\u8bba<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089 + \u4f20\u7edf\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">80\/60\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">~90%<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6b63\u5e38\u5339\u914d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089 + \u5730\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\">40\/50\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">~50-60%<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u6548\u7387\u6781\u4f4e\uff0c\u8fd8\u53ef\u80fd\u8150\u8680<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089 + \u5730\u6696<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>35-45\u2103<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>~108%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6700\u4f73\u7ec4\u5408<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089 + \u4f4e\u6e29\u6696\u6c14\u7247<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>55-65\u2103<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>~105%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u4f18\u79c0\u5339\u914d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089 + \u4f20\u7edf\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">80\/60\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">~93%<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f \u51b7\u51dd\u6548\u679c\u6d88\u5931\uff0c\u7b49\u4e8e\u4e70\u8d35\u4e86<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f&nbsp;<strong>\u51b7\u51dd\u89e6\u53d1\u6761\u4ef6<\/strong>\uff1a\u56de\u6c34\u6e29\u5ea6\u5fc5\u987b\u4f4e\u4e8e\u70df\u6c14\u9732\u70b9\u6e29\u5ea6\uff08\u7ea653-55\u2103\uff09\uff0c\u6c34\u84b8\u6c14\u624d\u4f1a\u51b7\u51dd\u3001\u91ca\u653e\u6f5c\u70ed\u3002\u4f20\u7edf\u6696\u6c14\u7247\u56de\u6c3460\u2103\u4ee5\u4e0a\uff0c\u51b7\u51dd\u5b8c\u5168\u4e0d\u53d1\u751f\u3002<\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"fsm03\" class=\"wp-block-heading\">\u7b2c\u4e09\u7ae0\uff1a\u83f2\u65af\u66fc\u54c1\u724c\u4e0e\u4ea7\u54c1\u7ebf<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u83f2\u65af\u66fc\u5b98\u7f51 + \u7ecf\u9500\u5546\u6e20\u9053 + \u77e5\u4e4e\u62c6\u673a\u8bc4\u6d4b + \u83f2\u65af\u66fc2016\u5fb7\u56fd\u603b\u90e8\u63a2\u79d8\u4e4b\u65c5<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">3.1 \u767e\u5e74\u54c1\u724c\u91cc\u7a0b\u7891<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91cc\u7a0b\u7891<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\/\u4ea7\u54c1\u521b\u65b0<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>1917\u5e74<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea6\u7ff0\u00b7\u83f2\u65af\u66fc\u5728\u5fb7\u56fd\u970d\u592b\u521b\u7acb\u516c\u53f8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u521d\u5236\u9020\u519c\u673a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1928\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f00\u59cb\u751f\u4ea7\u52a0\u70ed\u9505\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7533\u8bf7\u4ea7\u54c1\u4e0e\u9020\u578b\u8bbe\u8ba1\u4e13\u5229<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1957\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6c49\u8bfa\u5a01\u5c55\u4f1a\u63a8\u51fa\u53cc\u71c3\u6599\u9505\u7089Triola<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ef\u91c7\u7528\u56fa\u4f53\u71c3\u6599\u548c\u71c3\u6cb9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>1970\u5e74\u4ee3<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e16\u754c\u7387\u5148\u63a8\u51fa\u4e0d\u9508\u94a2\u9505\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f9b\u70ed\u6280\u672f\u53f2\u4e0a\u7684\u91cc\u7a0b\u7891<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1976\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f00\u59cb\u751f\u4ea7\u592a\u9633\u80fd\u96c6\u70ed\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fdb\u519b\u53ef\u518d\u751f\u80fd\u6e90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1978\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9996\u53f0\u70ed\u6cf5\u8fdb\u5165\u5e02\u573a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62d3\u5c55\u70ed\u6cf5\u6280\u672f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1980s<\/td><td class=\"has-text-align-left\" data-align=\"left\">Matrix\u8f90\u5c04\u71c3\u70e7\u5668\u6280\u672f\u7a81\u7834<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u6548\u71c3\u70e7\u3001\u964d\u4f4e\u6709\u5bb3\u7269\u8d28\u6392\u653e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>1997\u5e74<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8fdb\u5165\u4e2d\u56fd\u5e02\u573a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63a8\u51faVITODENS 100 CC\u51b7\u51dd\u7089<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2000s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63a8\u51faVitodens\u51b7\u51dd\u7089\u7cfb\u5217<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2Inox-Radial\u4e3b\u6362\u70ed\u5668<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2020s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u667a\u80fd\u4e92\u8054\u529f\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">APP\u8fdc\u7a0b\u63a7\u5236<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2024\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e76\u5165\u5f00\u5229\u5168\u7403\u516c\u53f8\uff08Carrier\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u7403\u6696\u901a\u7a7a\u8c03\u5de8\u5934\uff0c\u70ed\u6cf5\u6280\u672f\u50a8\u5907<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">3.2 \u4ea7\u54c1\u7ebf\u5168\u666f\u56fe<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u4f4d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u7387\u8303\u56f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6362\u70ed\u5668<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u56fd\u5e02\u573a\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7c7b\u578b<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Vitodens 300-W<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65d7\u8230\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.9-32kW\uff08\u58c1\u6302\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2 Inox-Radial<\/td><td class=\"has-text-align-left\" data-align=\"left\">B1KF<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u4e24\u7528\u7089<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Vitodens 200-W<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u7aef\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">49-150kW\uff08\u58c1\u6302\/\u843d\u5730\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2 Inox-Radial<\/td><td class=\"has-text-align-left\" data-align=\"left\">B2HA<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u5355\u91c7\u6696<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Vitodens 100-C<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u529b\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.1-35kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2 Inox-Radial<\/td><td class=\"has-text-align-left\" data-align=\"left\">B1JG\uff08\u56fd\u4ea7\uff09\/B1JD\uff08\u8fdb\u53e3\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u4e24\u7528\u7089<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Vitopend 100-W<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ecf\u6d4e\u578b\u5e38\u89c4\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">6-36kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dc\u8d28\u591a\u5c42\u9632\u8150<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE\/A1JD<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e38\u89c4\u4e24\u7528\u7089<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">3.3 Vitodens 300-W \u65d7\u8230\u7279\u6027\uff08B1KF\u8fdb\u53e3\u7cfb\u5217\uff09<\/h3>\n\n<p class=\"wp-block-paragraph\">\u83f2\u65af\u66fc\u7684\u9876\u7ea7\u5bb6\u7528\u51b7\u51dd\u7089\uff0c\u5fb7\u56fd\u963f\u4f26\u591a\u592b\u539f\u88c5\u8fdb\u53e3\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>7\u82f1\u5bf8\u5f69\u8272\u89e6\u6478\u5c4f<\/strong>\uff0c\u64cd\u4f5c\u76f4\u89c2<\/li>\n\n<li><strong>Lambda Pro Control Plus<\/strong>&nbsp;\u81ea\u9002\u5e94\u71c3\u70e7\u63a7\u5236\uff1a\u9002\u7528\u5929\u7136\u6c14\/\u6db2\u5316\u6c14\/\u63ba\u6c2220%\u5929\u7136\u6c14\uff0c\u65e0\u9700\u6362\u55b7\u5634<\/li>\n\n<li><strong>\u8c03\u5236\u8303\u56f41:17<\/strong>\uff0832kW\u578b\u53f7\u6700\u5c0f\u529f\u7387\u4ec51.9kW\uff09\uff0c\u751f\u6d3b\u70ed\u6c34\u7a33\u5b9a\u6027\u6781\u4f73<\/li>\n\n<li><strong>\u9759\u97f3\u8fd0\u884c<\/strong>\uff1a\u4f4e\u98ce\u673a\u8f6c\u901f\u8bbe\u8ba1\uff0c\u53ef\u5b89\u88c5\u5728\u53a8\u623f\u67dc\u5185<\/li>\n\n<li><strong>H\u2082 Ready 20%<\/strong>\uff1a\u652f\u630120%\u6c22\u6c14\u6df7\u5408\u5929\u7136\u6c14\uff0c\u4e3a\u672a\u6765\u80fd\u6e90\u8f6c\u578b\u9884\u7559\u63a5\u53e3<\/li>\n\n<li><strong>Vitodens 333-F<\/strong>\uff1a\u5185\u7f6e\u50a8\u6c34\u7f50\u7684\u4e24\u7528\u7089\u7248\u672c\uff0c\u91c7\u6696\u70ed\u6c34\u4e00\u4f53\u89e3\u51b3\uff0c\u65e0\u9700\u5916\u914d\u6c34\u7bb1<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">3.4 \u8fdb\u53e3 vs \u56fd\u4ea7\u7ec4\u88c5\uff1a\u56db\u7ef4\u5bf9\u6bd4<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8fdb\u53e3\u7248\uff08B1KF\/B1JD\/WH1D\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u56fd\u4ea7\u7ec4\u88c5\u7248\uff08A1JE\/B1JG\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4ea7\u5730<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u56fd\u963f\u4f26\u591a\u592b\u539f\u88c5\u8fdb\u53e3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5317\u4eac\u5de5\u5382\u7ec4\u88c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u64cd\u4f5c\u65b9\u5f0f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65cb\u94ae\u5f0f\uff08\u5fb7\u7cfb\u7ecf\u5178\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6309\u952e\u5f0f\/\u89e6\u63a7\u5f0f\uff08\u672c\u5730\u5316\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u6cf5<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6cd5\u56fd\u683c\u5170\u5bcc\uff08\u8fdb\u53e3\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u56fd\u4ea7\u683c\u5170\u5bcc<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u71c3\u6c14\u6bd4\u4f8b\u9600<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u610f\u5927\u5229\u897f\u7279<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u672c\u897f\u95e8\u5b50<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5185\u90e8\u8fde\u63a5<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5de5\u7a0b\u5851\u6599\u5361\u63a5\uff08\u4fbf\u4e8e\u7ef4\u4fee\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dc\u7ba1\u4ef6\u8fde\u63a5\uff08\u6c34\u529b\u963b\u529b\u7565\u5927\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ed3\u6784\u8bbe\u8ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u56fd\u539f\u7248<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0e\u539f\u88c5\u4e00\u81f4\uff08\u672c\u5730\u5316\u9002\u914d\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u540c\u529f\u7387\u4ef7\u5dee<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d35\u7ea62,000-5,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u57fa\u51c6\u4ef7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6838\u5fc3\u90e8\u4ef6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u56fd\u539f\u88c5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fdb\u53e3\u6838\u5fc3\u4ef6+\u56fd\u5185\u7ec4\u88c5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1&nbsp;<strong>\u9009\u62e9\u5efa\u8bae<\/strong>\uff1a\u9884\u7b97\u6709\u9650\u2192\u56fd\u4ea7B1JG\uff08\u6838\u5fc3\u90e8\u4ef6\u4ecd\u4e3a\u8fdb\u53e3\uff0c\u6027\u4ef7\u6bd4\u6781\u9ad8\uff09\uff1b\u8ffd\u6c42\u6781\u81f4\u54c1\u8d28\u2192\u8fdb\u53e3B1KF\uff08\u5fb7\u7cfb\u5168\u539f\u88c5\uff0c\u54c1\u63a7\u4e25\u683c\uff09\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">3.5 \u56fd\u4ea7\u4e3b\u529b\u578b\u53f7\u53c2\u6570\u901f\u67e5<\/h3>\n\n<h4 class=\"wp-block-heading\">Vitopend 100-W A1JE\uff08\u5e38\u89c4\u7089\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">24.8kW<\/th><th class=\"has-text-align-left\" data-align=\"left\">30kW<\/th><th class=\"has-text-align-left\" data-align=\"left\">36kW<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u70ed\u8f93\u51fa\uff08\u4f9b\u6696\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.0\u201324.8kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">7.5\u201330.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">9.0\u201336.0kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6bd4\u4f8b\u8c03\u8282\u8303\u56f4<\/td><td class=\"has-text-align-left\" data-align=\"left\">1:4<\/td><td class=\"has-text-align-left\" data-align=\"left\">1:4<\/td><td class=\"has-text-align-left\" data-align=\"left\">1:4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u4ea7\u7387\uff08\u0394T=25K\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">13.4 L\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">16.4 L\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">20.6 L\/min<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u566a\u97f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt;49 dB(A)<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt;51 dB(A)<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt;51.6 dB(A)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c3a\u5bf8\uff08\u9ad8\u00d7\u5bbd\u00d7\u539a\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">725\u00d7400\u00d7350mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">725\u00d7480\u00d7350mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">725\u00d7480\u00d7350mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u71c3\u6c14\u8017\u91cf\uff08\u6700\u5927\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">  2.88 m\u00b3\/h <\/td><td class=\"has-text-align-left\" data-align=\"left\">|3.50 m\u00b3\/h |<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.20 m\u00b3\/h <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9f99\u8109\u9762\u4ef7\uff082026\u5e74\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a58,311<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a59,897<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a511,524<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">Vitodens 100-C SE B1JG\uff08\u51b7\u51dd\u7089\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">19kW<\/th><th class=\"has-text-align-left\" data-align=\"left\">25kW<\/th><th class=\"has-text-align-left\" data-align=\"left\">35kW<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u70ed\u8f93\u51fa\uff0850\/30\u2103\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.1\u201319.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.1\u201325.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.1\u201335.0kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6ee1\u8d1f\u8377\u6548\u7387\uff0850\/30\u2103\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">105.3%<\/td><td class=\"has-text-align-left\" data-align=\"left\">107.5%<\/td><td class=\"has-text-align-left\" data-align=\"left\">104.7%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u70e7\u5668\u8c03\u8282\u6bd4<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>1:11<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>1:11<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>1:11<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u751f\u6d3b\u70ed\u6c34\u6c34\u91cf\uff08\u0394T=25K\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">14.8 kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">17.8 kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">20.7 kg\/min<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u566a\u97f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">52 dB(A)<\/td><td class=\"has-text-align-left\" data-align=\"left\">53 dB(A)<\/td><td class=\"has-text-align-left\" data-align=\"left\">52 dB(A)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c3a\u5bf8\uff08\u9ad8\u00d7\u5bbd\u00d7\u539a\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">700\u00d7400\u00d7300mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">700\u00d7400\u00d7300mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">700\u00d7400\u00d7300mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e00\u7ea7<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e00\u7ea7<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e00\u7ea7<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u71c3\u6c14\u8017\u91cf\uff08\u6700\u5927\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;2.10 m\u00b3\/h&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.76 m\u00b3\/h<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3.70 m\u00b3\/h<\/strong>&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9f99\u8109\u9762\u4ef7\uff082026\u5e74\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a512,238<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a513,597<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a516,465<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">3.6 A1JE vs B1JG \u6838\u5fc3\u5dee\u5f02<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">A1JE\uff08\u5e38\u89c4\u7089\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">B1JG\uff08\u51b7\u51dd\u7089\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e00\u7ea7<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">93%<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>98%\/108%<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u529f\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3.1kW<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8c03\u8282\u6bd4<\/td><td class=\"has-text-align-left\" data-align=\"left\">1:4<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>1:11<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u70e7\u6280\u672f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u9884\u6df7\u5f0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u51b7\u51dd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u6362\u70ed\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dc\u8d28<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e0d\u9508\u94a2 Inox<\/strong>\uff08\u8010\u8150\u8680\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u6700\u5927\u957f\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22644m<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u22648m<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u5761\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5411\u4e0b\u22653\u00b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5411\u4e0a\u22653\u00b0\uff08\u65b9\u5411\u76f8\u53cd\uff01\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u81ea\u9002\u5e94<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u652f\u6301<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u652f\u6301<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u590f\u5929\u6d17\u6fa1\u4f53\u9a8c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u822c<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f18\u79c0<\/strong>\uff083.1kW\u6700\u5c0f\u529f\u7387\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4ef7\u683c\uff0824-26kW\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a58,000-10,000<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a515,000-18,000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u56de\u672c\u5468\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea64-6\u5e74\uff08\u71c3\u6c14\u8282\u7701\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f&nbsp;<strong>\u5173\u952e\u63d0\u9192<\/strong>\uff1a\u5e38\u89c4\u7089\u70df\u7ba1\u5411\u4e0b\u503e\u659c\uff08\u9632\u96e8\u6c34\u5012\u704c\uff09\uff0c\u51b7\u51dd\u7089\u70df\u7ba1\u5411\u4e0a\u503e\u659c\uff08\u51b7\u51dd\u6c34\u56de\u6d41\u81f3\u9505\u7089\u6536\u96c6\uff09\u3002<strong>\u65b9\u5411\u5b8c\u5168\u76f8\u53cd\uff0c\u5b89\u88c5\u65f6\u4e0d\u53ef\u6df7\u6dc6\u3002<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/longmai-nt.com\/?page_id=3533\">\u4e86\u89e3\u83f2\u65af\u66fcA1JE\u5e38\u89c4\u4e24\u7528\u7089\u8be6\u60c5\u8bf7\u70b9\u51fb\u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/longmai-nt.com\/?page_id=2553\">\u4e86\u89e3\u83f2\u65af\u66fc\u56fd\u4ea7\u51b7\u51dd\u7089B1JG25KW\u8be6\u60c5\u8bf7\u70b9\u51fb\u2192<\/a><\/p>\n<\/blockquote>\n\n<div class=\"lmwp-wrap lmwp-relcard\">\n  <h3>\u83f2\u65af\u66fc\u673a\u578b\u8be6\u60c5<\/h3>\n  <div class=\"grid\">\n    <a class=\"card\" href=\"https:\/\/longmai-nt.com\/?page_id=13053\">\n      <b>\u83f2\u65af\u66fc 18kW \u5355\u91c7\u6696\u58c1\u6302\u7089 A1GF<\/b>\n      <span>\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u4e13\u7528\u5355\u91c7\u6696\u7089\uff0c5.4\u201318kW \u8f93\u51fa\uff1b\u5bf9\u6bd4 A1JF \u4e24\u7528\u7089\u600e\u4e48\u9009\uff0c\u542b\u6210\u90fd\u6210\u5957\u53c2\u8003\u4ef7\u4e0e 7 \u6b65\u5b89\u88c5\u6d41\u7a0b\u3001\u771f\u5b9e\u843d\u5730\u6848\u4f8b\u3002<\/span>\n    <\/a>\n  <\/div>\n<\/div>\n<style>\n.lmwp-wrap.lmwp-relcard{margin:28px 0;padding:20px;background:#fff;border:1px solid #e3e8f0;border-radius:12px}\n.lmwp-wrap.lmwp-relcard h3{margin:0 0 14px;font-size:15px;font-weight:500;color:#1a2b4a}\n.lmwp-wrap.lmwp-relcard .grid{display:grid;grid-template-columns:1fr;gap:12px}\n.lmwp-wrap.lmwp-relcard .card{display:block;padding:14px 16px;background:#f7f9fc;border-radius:8px;text-decoration:none}\n.lmwp-wrap.lmwp-relcard .card:hover{background:#eef3fb}\n.lmwp-wrap.lmwp-relcard .card b{display:block;font-size:14px;color:#1a2b4a;margin-bottom:6px}\n.lmwp-wrap.lmwp-relcard .card span{display:block;font-size:12px;line-height:1.7;color:#5a6b85}\n<\/style>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"fsm04\" class=\"wp-block-heading\">\u7b2c\u56db\u7ae0\uff1a\u6838\u5fc3\u6280\u672f\u89e3\u6790<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u9a6c\u7ef4\u65af\u00b7\u5916\u7f51\u8d44\u6599 + IMA\u77e5\u8bc6\u5e93\u00b7\u9f99\u8109\u6696\u901a\u7b2c\u4e8c\u7bc7\/\u7b2c\u516d\u7bc7 + \u83f2\u65af\u66fc\u5b98\u7f51\u6280\u672f\u6587\u6863<\/p>\n<\/blockquote>\n\n<h3 id=\"fsm0401\" class=\"wp-block-heading\">4.1 \u51b7\u51dd\u7089\u4e3a\u4ec0\u4e48\u7701\u6c14\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u539f\u7406<\/strong>\uff1a\u5929\u7136\u6c14\u71c3\u70e7\u4ea7\u751f\u7684\u6c34\u84b8\u6c14\uff08\u70df\u6c14\u4e2d\u7ea610-11%\u7684\u70ed\u91cf\u4ee5\u6c34\u84b8\u6c14\u5f62\u5f0f\u5b58\u5728\uff09\uff0c\u5728\u6362\u70ed\u5668\u8868\u9762\u51b7\u51dd\u6210\u6c34\uff0c\u91ca\u653e<strong>\u6c7d\u5316\u6f5c\u70ed<\/strong>\uff0c\u4f7f\u70ed\u6548\u7387\u7a81\u7834100%\u3002<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6392\u70df\u6e29\u5ea6\u76f4\u89c2\u5bf9\u6bd4<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u5e38\u89c4\u7089\uff1a\u6392\u70df\u6e29\u5ea6&nbsp;<strong>110-200\u2103<\/strong>\uff08\u5927\u91cf\u663e\u70ed\u88ab\u70df\u6c14\u5e26\u8d70\uff09<\/li>\n\n<li>\u51b7\u51dd\u7089\uff1a\u6392\u70df\u6e29\u5ea6&nbsp;<strong>40-60\u2103<\/strong>\uff08\u663e\u70ed+\u6f5c\u70ed\u53cc\u91cd\u56de\u6536\uff0c\u6392\u70df\u6e29\u5ea6\u63a5\u8fd1\u5ba4\u6e29\uff09 \u6392\u70df\u6e29\u5ea6\u8d8a\u4f4e\uff0c\u8bf4\u660e\u70ed\u91cf\u56de\u6536\u8d8a\u5f7b\u5e95\u3002<\/li>\n<\/ul>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u524d\u63d0<\/strong>\uff1a\u4f4e\u6e29\u8fd0\u884c\u3002\u53ea\u6709\u4f9b\u6c34\u6e29\u5ea6\u4f4e\u4e8e55\u2103\uff0c\u70df\u6c14\u4e2d\u7684\u6c34\u84b8\u6c14\u624d\u4f1a\u5927\u91cf\u51b7\u51dd\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u51b5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u56de\u6c34\u6e29\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u72b6\u6001<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089 + \u5730\u6696\uff0835-45\u2103\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">30-35\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6301\u7eed\u6700\u4f73\u51b7\u51dd<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>105-110%<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089 + \u4f4e\u6e29\u6696\u6c14\u7247\uff0855-65\u2103\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">40-50\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6301\u7eed\u51b7\u51dd<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>~105%<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089 + \u4f20\u7edf\u6696\u6c14\u7247\uff0880\u2103\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">60\u2103+<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u51b7\u51dd\u6d88\u5931<\/td><td class=\"has-text-align-left\" data-align=\"left\">~93%\uff08\u7b49\u4e8e\u666e\u901a\u7089\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f&nbsp;<strong>\u6700\u5927\u8bef\u533a<\/strong>\uff1a\u4e70\u4e86\u51b7\u51dd\u7089\uff0c\u5374\u914d\u4e86\u4f20\u7edf\u6696\u6c14\u7247\uff08\u4f9b\u6c3470-80\u2103\uff09\uff0c\u56de\u6c3460\u2103\u4ee5\u4e0a\uff0c\u51b7\u51dd\u5b8c\u5168\u4e0d\u53d1\u751f\u3002<strong>\u51b7\u51dd\u7089\u767d\u4e70\u4e86\u3002<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f&nbsp;<strong>\u6c34\u8d28\u8981\u6c42\uff08\u51b7\u51dd\u7089\u72ec\u6709\uff09<\/strong>\uff1a\u51b7\u51dd\u7089\u5bf9\u6c34\u8d28\u7eaf\u51c0\u5ea6\u8981\u6c42\u8f83\u9ad8\u3002\u786c\u6c34\u5730\u533a\uff08\u5982\u6c34\u57a2\u4e25\u91cd\u7684\u534e\u5317\uff09\u5efa\u8bae\u52a0\u88c5\u8f6f\u6c34\u8bbe\u5907\uff0c\u9632\u6b62\u6362\u70ed\u5668\u7ed3\u57a2\u5f71\u54cd\u6548\u7387\u548c\u5bff\u547d\u3002\u9178\u6027\u51b7\u51dd\u6c34\uff08pH 3.5-5.0\uff09\u4e5f\u4f1a\u52a0\u901f\u8150\u8680\uff0c\u6c34\u8d28\u5904\u7406\u4e0d\u53ef\u5ffd\u89c6\u3002<\/p>\n<\/blockquote>\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading has-icon has-icon-right\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">4.1.1 \u51b7\u51dd\u7089\u70ed\u6548\u7387\u201c\u8d85100%\u201d \u00b7 \u5fc5\u987b\u8bf4\u660e\u7684\u771f\u76f8<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n<div aria-labelledby=\"accordion-item-2\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<h5 class=\"wp-block-heading\">1. \u8fd9\u4e2a\u201c100%\u201d\u4e0d\u662f\u6b3a\u9a97\uff0c\u800c\u662f\u4e0d\u540c\u7684\u8ba1\u7b97\u57fa\u51c6<\/h5>\n\n<p class=\"wp-block-paragraph\">\u5f88\u591a\u5ba2\u6237\u7b2c\u4e00\u6b21\u542c\u5230\u201c\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u201d\u65f6\uff0c\u7b2c\u4e00\u53cd\u5e94\u662f\uff1a\u201c\u8fd9\u4e0d\u662f\u8fdd\u53cd\u80fd\u91cf\u5b88\u6052\u5b9a\u5f8b\u5417\uff1f\u5546\u5bb6\u5728\u9a97\u6211\uff1f\u201d<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u8fd9\u5176\u5b9e\u662f\u4e00\u4e2a\u884c\u4e1a\u901a\u7528\u7684\u8ba1\u7b97\u57fa\u51c6\u5dee\u5f02\u95ee\u9898\uff1a<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6982\u5ff5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u4e49<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9ad8\u4f4d\u70ed\u503c\uff08HHV\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5929\u7136\u6c14\u5b8c\u5168\u71c3\u70e7\u91ca\u653e\u7684<strong>\u603b\u70ed\u91cf<\/strong>\uff08\u5305\u542b\u6c34\u84b8\u6c14\u4e2d\u7684\u6f5c\u70ed\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd9\u662f\u7269\u7406\u5b66\u4e0a\u7684<strong>\u771f\u5b9e\u70ed\u80fd\u603b\u91cf<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f4e\u4f4d\u70ed\u503c\uff08LHV\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u4f4d\u70ed\u503c <strong>\u51cf\u53bb<\/strong> \u6c34\u84b8\u6c14\u6c7d\u5316\u6f5c\u70ed\uff08\u7ea610-11%\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd9\u662f<strong>\u884c\u4e1a\u901a\u7528\u7684\u8ba1\u7b97\u57fa\u51c6<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c7d\u5316\u6f5c\u70ed<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6c34\u84b8\u6c14\u4ece\u6c14\u6001\u53d8\u4e3a\u6db2\u6001\u65f6\u91ca\u653e\u7684\u70ed\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089\u65e0\u6cd5\u5229\u7528\uff0c<strong>\u51b7\u51dd\u7089\u53ef\u56de\u6536<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u9053\u7834\u5929\u673a\uff1a<\/strong><\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u201c108%\u662f\u6309\u884c\u4e1a\u901a\u7528\u7684\u4f4e\u70ed\u503c\u6807\u51c6\u7b97\u51fa\u6765\u7684\u3002\u6309\u771f\u5b9e\u603b\u70ed\u91cf\u7b97\uff0c\u51b7\u51dd\u7089\u6548\u7387\u7ea697%\uff0c\u6c38\u4e0d\u8d85100%\u3002\u8fd9\u4e2a108%\u7684\u610f\u601d\u662f\u2014\u2014\u5b83\u6bd4\u666e\u901a\u7089\u591a\u56de\u6536\u4e86\u70df\u6c14\u4e2d\u6c34\u84b8\u6c14\u7684\u70ed\u91cf\u3002\u201d<\/strong><\/p>\n<\/blockquote>\n\n<h5 class=\"wp-block-heading\">2. \u6548\u7387\u6362\u7b97\u516c\u5f0f<\/h5>\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u60a8\u60f3\u7ed9\u5ba2\u6237\u4e00\u4e2a\u66f4\u4e25\u8c28\u7684\u8ba1\u7b97\uff0c\u53ef\u4ee5\u7528\u8fd9\u4e2a\u666e\u901a\u6d88\u8d39\u8005\u80fd\u7406\u89e3\u7684\u6362\u7b97\uff1a<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u771f\u5b9e\u6548\u7387 \u2248 \u6807\u79f0\u6548\u7387 \u00d7 0.9<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7089\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6807\u79f0\u6548\u7387\uff08\u6309LHV\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u771f\u5b9e\u6548\u7387\uff08\u6309HHV\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089\uff08\u4e8c\u7ea7\u80fd\u6548\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">89-93%<\/td><td class=\"has-text-align-left\" data-align=\"left\">80-84%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\uff08\u4e00\u7ea7\u80fd\u6548\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">103-108%<\/td><td class=\"has-text-align-left\" data-align=\"left\">93-97%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7269\u7406\u672c\u8d28\uff1a<\/strong> \u51b7\u51dd\u7089\u591a\u56de\u6536\u4e86\u7ea610-11%\u7684\u6c7d\u5316\u6f5c\u70ed\uff0c\u56e0\u6b64\u5728\u4ee5\u4f4e\u70ed\u503c\u4e3a\u57fa\u51c6\u65f6\uff0c\u6548\u7387\u53ef\u8fbe108%\u3002\u4f46\u6309\u771f\u5b9e\u7684\u9ad8\u4f4d\u70ed\u503c\u8ba1\u7b97\uff0c\u6c38\u8fdc\u4e0d\u8d85\u8fc7100%\uff0c\u5b8c\u5168\u9075\u5b88\u80fd\u91cf\u5b88\u6052\u5b9a\u5f8b\u3002<\/p>\n\n<h5 class=\"wp-block-heading\">3. \u5ba2\u6237\u8bdd\u672f\u5efa\u8bae\uff08\u7528\u4e8eFAQ\u6216\u8bef\u533a\u6a21\u5757\uff09<\/h5>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237\u95ee\uff1a\u201c\u51b7\u51dd\u7089\u6548\u7387108%\u662f\u4e0d\u662f\u865a\u5047\u5ba3\u4f20\uff1f\u201d<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u6211\u4eec\u7684\u56de\u7b54\uff1a<\/strong><br>\u201c\u597d\u95ee\u9898\uff0c\u5f88\u591a\u5ba2\u6237\u90fd\u6709\u8fd9\u4e2a\u7591\u60d1\u3002108%\u662f\u6307\u6309\u7167\u884c\u4e1a\u901a\u7528\u7684\u2018\u4f4e\u70ed\u503c\u2019\u6807\u51c6\u8ba1\u7b97\u7684\u3002\u7b80\u5355\u8bf4\uff0c\u5929\u7136\u6c14\u71c3\u70e7\u540e\uff0c\u70df\u6c14\u4e2d\u6709\u4e00\u90e8\u5206\u6c34\u84b8\u6c14\uff0c\u666e\u901a\u7089\u76f4\u63a5\u628a\u5b83\u6392\u8d70\u4e86\uff0c\u70ed\u91cf\u6d6a\u8d39\u4e86\u3002\u51b7\u51dd\u7089\u53c8\u628a\u8fd9\u4efd\u70ed\u91cf\u6536\u56de\u6765\u4e86\u3002\u6240\u4ee5\u76f8\u6bd4\u666e\u901a\u7089\uff0c\u5b83\u786e\u5b9e\u591a\u4e8610%\u5de6\u53f3\u7684\u70ed\u91cf\u88ab\u5229\u7528\uff0c\u6240\u4ee5\u6807108%\u3002\u4f46\u6309\u7269\u7406\u5b66\u4e0a\u7684\u603b\u70ed\u91cf\u7b97\uff0c\u5b83\u6c38\u8fdc\u4e0d\u8d85\u8fc7100%\u3002<strong>\u6240\u4ee5\u8fd9\u4e0d\u662f\u6b3a\u9a97\uff0c\u800c\u662f\u884c\u4e1a\u6807\u51c6\u4e0d\u540c\u3002\u5173\u952e\u5728\u4e8e\u2014\u2014\u5b83\u6bd4\u666e\u901a\u7089\u591a\u7701\u4e8620-30%\u7684\u6c14\u3002<\/strong>\u201d<\/p>\n<\/blockquote>\n\n<h5 class=\"wp-block-heading\">4. \u91cd\u8981\u524d\u63d0\uff1a\u53ea\u6709\u4f4e\u6e29\u8fd0\u884c\u624d\u80fd\u201c\u8d85100%\u201d<\/h5>\n\n<p class=\"wp-block-paragraph\">\u5fc5\u987b\u5411\u5ba2\u6237\u5f3a\u8c03\uff0c\u8fd9\u4e2a\u201c108%\u201d\u7684\u60ca\u4eba\u6548\u7387\u6709\u4e00\u4e2a<strong>\u786c\u6027\u524d\u63d0<\/strong>\uff1a<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8282\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6761\u4ef6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6548\u7387\u8868\u73b0<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u2705 <strong>\u9ad8\u6548\u8fd0\u884c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c34\u6e29\u5ea6 \u2264 55\u2103\uff08\u914d\u5730\u6696\u6216\u4f4e\u6e29\u6696\u6c14\u7247\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u6548\u7387 105-108%<\/strong>\uff0c\u771f\u6b63\u8282\u80fd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u274c <strong>\u65e0\u6548\u8fd0\u884c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c34\u6e29\u5ea6 \u2265 55\u2103\uff08\u914d\u8001\u5f0f\u6696\u6c14\u7247\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\u4ec5 <strong>90-93%<\/strong>\uff0c\u4e0e\u666e\u901a\u7089\u65e0\u5f02<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n<h3 class=\"wp-block-heading\">4.2 \u5168\u9884\u6df7\u71c3\u70e7 vs \u5927\u6c14\u5f0f\u71c3\u70e7<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f\u71c3\u70e7\uff08A1JE\u5e38\u89c4\u7089\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u71c3\u70e7\uff08B1JG\u51b7\u51dd\u7089\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5de5\u4f5c\u539f\u7406<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u548c\u7a7a\u6c14\u5728\u71c3\u70e7\u5ba4\u6df7\u5408\u540e\u71c3\u70e7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u548c\u7a7a\u6c14\u9884\u5148\u6309\u6700\u4f73\u6bd4\u4f8b\u7cbe\u786e\u6df7\u5408<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u706b\u7130\u6e29\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\uff08~1500\u2103\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\uff08~1100\u2103\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6c61\u67d3\u7269\u6392\u653e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\uff08NOx\u3001CO\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6781\u4f4e\uff08\u73af\u4fdd\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">85-90%<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>105-110%<\/strong>\uff08\u4f4e\u6e29\u5de5\u51b5\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7ed3\u57a2\u98ce\u9669<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\uff08\u4f4e\u6e29\u8fd0\u884c\uff0c\u7ed3\u57a2\u5c11\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">NOx\u6392\u653e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u964d\u4f4e90%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\ud83c\udf3f&nbsp;<strong>\u73af\u4fdd\u4f18\u52bf<\/strong>\uff1a\u5168\u9884\u6df7\u71c3\u70e7\u914d\u5408\u51b7\u51dd\u6280\u672f\uff0cNOx\u6392\u653e\u91cf\u6bd4\u5927\u6c14\u5f0f\u71c3\u70e7\u964d\u4f4e<strong>90%\u4ee5\u4e0a<\/strong>\uff0cCO\u6392\u653e\u4e5f\u5927\u5e45\u51cf\u5c11\uff0c\u7b26\u5408\u6b27\u6d32\u6700\u4e25\u73af\u4fdd\u6807\u51c6\uff08Class 5\uff09\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">4.3 \u4e0d\u9508\u94a2\u6362\u70ed\u5668 vs \u94dc\u6362\u70ed\u5668<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u94dc\u6362\u70ed\u5668\uff08A1JE\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2\u6362\u70ed\u5668\uff08B1JG\/B1KF\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5bfc\u70ed\u6548\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8f83\u4f4e\uff08\u9700\u52a0\u5bc6\u7fc5\u7247\u8865\u507f\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6297\u8150\u8680\u6027<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5dee\uff08\u9178\u6027\u51b7\u51dd\u6c34\u6613\u8150\u8680\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f18<\/strong>\uff08\u8010\u9178\u78b1\uff0c\u5bff\u547d15\u5e74\u4ee5\u4e0a\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u7089\u578b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089\uff08\u9ad8\u6e29\u8fd0\u884c\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089\uff08\u5fc5\u9009\uff09<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u83f2\u65af\u66fc\u6280\u672f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u591a\u5c42\u9632\u8150\u5904\u7406<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>Inox-Radial\u77e9\u9635\u5f0f<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1 \u51b7\u51dd\u7089\u5fc5\u987b\u9009\u4e0d\u9508\u94a2\u6362\u70ed\u5668\u3002\u94dc\u6362\u70ed\u5668\u5728\u9178\u6027\u51b7\u51dd\u6c34\uff08pH 3.5-5.0\uff09\u73af\u5883\u4e0b\u4f1a\u5feb\u901f\u8150\u8680\u7a7f\u5b54\uff0c\u5bff\u547d\u53ef\u80fd\u4ec53-5\u5e74\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">4.4 \u83f2\u65af\u66fc\u81ea\u7814\u6280\u672f<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e94\u7528\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u4f18\u52bf<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Inox-Radial\u77e9\u9635\u5f0f\u6362\u70ed\u5668<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Vitodens\u5168\u7cfb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d85\u5353\u8010\u8150\u8680\u6027\u548c\u70ed\u4f20\u5bfc\u6027\uff0c\u786e\u4fdd\u957f\u671f\u9ad8\u6548<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>MatriX-Plus\u5706\u67f1\u5f62\u71c3\u70e7\u5668<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">B1JG\/B1KF<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u71c3\u70e7\uff0c\u706b\u7130\u77ed\u4fc3\u84dd\u8272\uff0c\u71c3\u70e7\u5145\u5206<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Lambda Pro Control Plus<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Vitodens 300-W<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ea\u9002\u5e94\u71c3\u70e7\u63a7\u5236\uff0c\u81ea\u52a8\u9002\u914d\u5929\u7136\u6c14\/\u6db2\u5316\u6c14\/\u63ba\u6c2220%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u71c3\u6c14\u81ea\u9002\u5e94<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">B1JG\u65b0\u6b3e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ea\u52a8\u9002\u5e94\u4e0d\u540c\u6c14\u8d28\uff0c\u65e0\u9700\u4eba\u5de5\u8c03\u6574<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>VSM-01\u667a\u8054\u6a21\u7ec4<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u7cfb\u9009\u914d<\/td><td class=\"has-text-align-left\" data-align=\"left\">WiFi\u8fdc\u7a0b\u63a7\u5236\uff0cAPP\u76d1\u63a7\u8fd0\u884c\u72b6\u6001<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">4.5 \u4f4e\u6e29\u6696\u6c14\u7247 + \u51b7\u51dd\u7089\u5339\u914d\u65b9\u6848<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u539f\u5219<\/strong>\uff1a\u901a\u8fc7\u589e\u5927\u6563\u70ed\u9762\u79ef\uff0c\u4f7f\u6696\u6c14\u7247\u572850-55\u2103\u4f4e\u6e29\u4e0b\u4ecd\u80fd\u8fbe\u5230\u8bbe\u8ba1\u6563\u70ed\u91cf\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9009\u578b\u65b9\u6cd5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5177\u4f53\u64cd\u4f5c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u5927\u89c4\u683c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u630980\/60\u2103\u6807\u79f0\u6563\u70ed\u91cf\u7684<strong>1.5-2\u500d<\/strong>\u9009\u578b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9009\u7528\u4f4e\u6e29\u4e13\u7528\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94a2\u5236\u677f\u5f0f\uff08PURMO\u3001Kermi\uff09\u3001\u94dc\u94dd\u590d\u5408\u591a\u67f1\u5f0f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u591a\u914d\u7ec4\u6570<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u623f\u95f4\u6bd4\u4f20\u7edf\u65b9\u6848\u591a\u52a01-2\u7ec4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6c14\u5019\u8865\u507f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f00\u542f\u51b7\u51dd\u7089\u6c14\u5019\u8865\u507f\u529f\u80fd\uff0c\u4f9b\u6c34\u6e29\u5ea6\u968f\u5ba4\u5916\u6e29\u5ea6\u81ea\u52a8\u8c03\u8282<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6563\u70ed\u91cf\u6298\u7b97\u793a\u4f8b<\/strong>\uff08\u6807\u79f01000W\u6696\u6c14\u7247\uff09\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5de5\u51b5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6563\u70ed\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u72b6\u6001<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c3475\u2103\/\u56de\u6c3460\u2103\/\u5ba4\u6e2920\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2248750W<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e0\u51b7\u51dd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c3455\u2103\/\u56de\u6c3445\u2103\/\u5ba4\u6e2920\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2248530W<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6301\u7eed\u51b7\u51dd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c3445\u2103\/\u56de\u6c3435\u2103\/\u5ba4\u6e2920\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2248340W<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u4f73\u51b7\u51dd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"fsm05\" class=\"wp-block-heading\">\u7b2c\u4e94\u7ae0\uff1a\u9009\u578b\u6307\u5357<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1aIMA\u77e5\u8bc6\u5e93\u00b7\u9f99\u8109\u6696\u901a\u7b2c\u4e94\u7bc7\/\u7b2c\u516d\u7bc7\u00b7\u8bbe\u8ba1\u89c4\u8303V4.1<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">5.1 \u56db\u6b65\u9009\u578b\u6cd5<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e00\u6b65\uff1a\u770b\u9762\u79ef\u5b9a\u529f\u7387<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u91c7\u7528\"\u6700\u63a5\u8fd1\uff08\u4e0d\u8d85\u8fc7120%\uff09\u8bbe\u8ba1\u70ed\u8d1f\u8377\"\u539f\u5219\uff0c\u4ee5\u5ddd\u6e1d\u5730\u533a\u6807\u51c6\u8282\u80fd\u4f4f\u5b85\uff08\u8bbe\u8ba1\u8d1f\u8377\u7ea650W\/\u33a1\uff09\u4f30\u7b97\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u70ed\u8d1f\u8377<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u83f2\u65af\u66fc\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">80\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE 24kW \/ B1JG 19kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u529f\u7387\u6700\u63a5\u8fd1\uff0c\u907f\u514d\u5927\u9a6c\u62c9\u5c0f\u8f66<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">100\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">5.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE 24kW \/ B1JG 25kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e02\u573a\u4e3b\u6d41\u529f\u7387\uff0c\u5339\u914d\u5ea6\u9ad8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">140\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">7.0kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE 30kW \/ B1JG 35kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u5927\u6237\u578b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">200\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">10kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE 30kW + \u7cfb\u7edf\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d85\u8fc7200\u33a1\u9700\u4e8c\u6b21\u7cfb\u7edf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e8c\u6b65\uff1a\u770b\u672b\u7aef\u5b9a\u7c7b\u578b<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u672b\u7aef\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u9505\u7089<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7406\u7531<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089<\/strong>\uff08B1JG\/B1KF\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u56de\u6c3435-45\u2103\uff0c\u51b7\u51dd\u6548\u7387\u6700\u9ad8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6e29\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089<\/strong>\uff08B1JG\/B1KF\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u56de\u6c3455-65\u2103\uff0c\u53ef\u53d1\u6325\u51b7\u51dd\u4f18\u52bf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f20\u7edf\u6696\u6c14\u7247\uff08\u8001\u623f\u6539\u9020\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e38\u89c4\u7089\uff08A1JE\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6c3470-80\u2103\uff0c\u51b7\u51dd\u7089\u65e0\u4f18\u52bf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e09\u6b65\uff1a\u770b\u9884\u7b97\u5b9a\u6863\u6b21<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9884\u7b97\u8303\u56f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u65b9\u6848<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u00a56,000-10,000<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE\u5e38\u89c4\u7089\uff08\u6027\u4ef7\u6bd4\u4e4b\u9009\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u00a512,000-17,000<\/td><td class=\"has-text-align-left\" data-align=\"left\">B1JG\u56fd\u4ea7\u51b7\u51dd\u7089\uff08\u8282\u80fd\u4e4b\u9009\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u00a518,000-28,000+<\/td><td class=\"has-text-align-left\" data-align=\"left\">B1KF\u8fdb\u53e3\u51b7\u51dd\u7089\uff08\u54c1\u8d28\u4e4b\u9009\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u56db\u6b65\uff1a\u4e24\u7528\u7089 vs \u70ed\u6c34\u5206\u7acb<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7f3a\u70b9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e24\u7528\u7089\uff08A1JE\/B1JG\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2264120\u33a1\uff0c1-2\u536b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7701\u7a7a\u95f4\u3001\u6210\u672c\u4f4e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u590f\u5b63\u70ed\u6c34\u53ef\u80fd\u4e0d\u7a33<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e24\u7528\u7089+\u5916\u7f6e\u6c34\u7bb1<\/td><td class=\"has-text-align-left\" data-align=\"left\">120-200\u33a1\uff0c2-3\u536b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u7a33\u5b9a\u3001\u96f6\u51b7\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5360\u5730\u5927\u3001\u6210\u672c\u9ad8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Vitodens 333-F<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2264180\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u96c6\u6210\u6c34\u7bb1\uff0c\u7701\u7a7a\u95f4<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6c34\u7bb1\u5bb9\u91cf\u6709\u9650<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u7089+300L\u6c34\u7bb1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u522b\u5885\/\u5927\u5e73\u5c42<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6052\u6e29\u5927\u6d41\u91cf\u3001\u591a\u70b9\u7528\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u521d\u6210\u672c\u6700\u9ad8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1&nbsp;<strong>\u70ed\u6c34\u7528\u91cf\u53c2\u8003\uff08\u5e2e\u4f60\u5224\u65ad\u81ea\u5bb6\u9700\u6c42\uff09<\/strong>\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7528\u6c34\u573a\u666f<\/th><th>\u6d41\u91cf\u53c2\u8003<\/th><\/tr><\/thead><tbody><tr><td>\u53a8\u623f\u9f99\u5934\uff08\u70ed\u6c34\uff09<\/td><td>~5 L\/min<\/td><\/tr><tr><td>\u666e\u901a\u82b1\u6d12\u6dcb\u6d74<\/td><td>~8 L\/min<\/td><\/tr><tr><td>\u9ad8\u6863\u82b1\u6d12\/\u9876\u55b7<\/td><td>~13 L\/min<\/td><\/tr><tr><td>\u6d74\u7f38\u6ce8\u6ee1<\/td><td>150-200 L\uff08\u7ea610-15\u5206\u949f\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">24kW\u4e24\u7528\u7089\u70ed\u6c34\u4ea7\u7387\u7ea613.4 L\/min\uff08\u0394T=25K\uff09\uff0c\u53ef\u540c\u65f6\u6ee1\u8db3\u4e00\u53a8\u4e00\u536b\uff1b\u4e24\u536b\u540c\u65f6\u6d17\u6fa1\u5efa\u8bae\u900928kW+\u6216\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">5.2 \u51b7\u51dd\u7089 vs \u666e\u901a\u7089\uff1a\u7ecf\u6d4e\u6027\u6d4b\u7b97<\/h3>\n\n<p class=\"wp-block-paragraph\">\u4ee5120\u33a1\u5730\u6696\u4e3a\u4f8b\uff0c\u71c3\u6c14\u5355\u4ef73.2\u5143\/m\u00b3\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e38\u89c4\u7089\uff08A1JE\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\uff08B1JG\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e74\u8017\u6c14\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">~2,160m\u00b3<\/td><td class=\"has-text-align-left\" data-align=\"left\">~1,750m\u00b3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e74\u71c3\u6c14\u8d39<\/td><td class=\"has-text-align-left\" data-align=\"left\">~\u00a56,912<\/td><td class=\"has-text-align-left\" data-align=\"left\">~\u00a55,600<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5e74\u8282\u7701<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>~\u00a51,312<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u673a\u5668\u5dee\u4ef7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">~\u00a55,000-6,000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u56de\u672c\u5468\u671f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ea64-5\u5e74<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1 \u6c14\u4ef7\u8d8a\u9ad8\uff08\u5982\u4e0a\u6d774\u5143\/m\u00b3\uff09\uff0c\u56de\u672c\u8d8a\u5feb\uff08\u7ea63\u5e74\uff09\u3002\u957f\u671f\u81ea\u4f4f\uff0c\u51b7\u51dd\u7089\u7684\u7ecf\u6d4e\u6027\u4f18\u52bf\u660e\u663e\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">5.3 \u51b7\u51dd\u7089 vs \u666e\u901a\u7089\u51b3\u7b56\u6811<\/h3>\n\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/longmai-nt.com\/?page_id=3533\">\u4e86\u89e3\u83f2\u65af\u66fcA1JE\u5e38\u89c4\u4e24\u7528\u7089\u8be6\u60c5\u8bf7\u70b9\u51fb\u2192<\/a><br><a href=\"https:\/\/longmai-nt.com\/?page_id=2553\">\u4e86\u89e3\u83f2\u65af\u66fc\u56fd\u4ea7\u51b7\u51dd\u7089B1JG25KW\u8be6\u60c5\u8bf7\u70b9\u51fb\u2192<\/a><\/pre>\n\n<h3 class=\"wp-block-heading\">5.4 \u4e24\u7528\u7089 vs \u7cfb\u7edf\u7089 vs \u5355\u91c7\u6696\u7089<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7f3a\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u4ef7\u683c\u53c2\u8003<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e24\u7528\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u5c0f\u6237\u578b\u3001\u5df2\u6709\u70ed\u6c34\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u673a\u4e24\u7528\uff0c\u8282\u7701\u7a7a\u95f4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u8f93\u51fa\u53d7\u9650\uff0c\u590f\u5929\u53ef\u80fd\u8fc7\u70eb\uff0c\u51ac\u5b63\u5f71\u54cd\u91c7\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u83f2\u65af\u66fc\u51b7\u51dd\u4e24\u7528 25KW: ~16,000\u5143<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7cfb\u7edf\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6237\u578b\u3001\u522b\u5885\u3001\u5bf9\u70ed\u6c34\u8981\u6c42\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ef\u8fde\u63a5\u70ed\u6c34\u7bb1\uff0c\u6052\u6e29\u5927\u6d41\u91cf\u70ed\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u8981\u5355\u72ec\u914d\u7f6e\u6c34\u7bb1\uff0c\u521d\u6210\u672c\u66f4\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">N\/A<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5355\u91c7\u6696\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5df2\u6709\u72ec\u7acb\u70ed\u6c34\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u70e7\u66f4\u5145\u5206\uff0c\u91c7\u6696\u4e0e\u70ed\u6c34\u5b8c\u5168\u5206\u79bb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u53e6\u914d\u70ed\u6c34\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u83f2\u65af\u66fc\u51b7\u51dd\u5355\u91c7\u6696: \u7ea613,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">5.5 \u91c7\u6696\u4e0e\u70ed\u6c34\u5206\u79bb\u65b9\u6848\uff08\u9ad8\u7aef\u63a8\u8350\uff09<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u65b9\u6848<\/strong>\uff1a<strong>\u91c7\u6696\u9505\u7089 + \u72ec\u7acb\u70ed\u6c34\u5668\/\u70ed\u6c34\u7bb1<\/strong>\u3002<br><strong>\u7406\u7531<\/strong>\uff1a\u907f\u514d\u4e24\u7528\u7089\u7684\u9891\u7e41\u542f\u505c\u3001\u70ed\u6c34\u8fc7\u70eb\u3001\u91c7\u6696\u4e0e\u70ed\u6c34\u4e89\u593a\u70ed\u6e90\u7b49\u95ee\u9898\u3002\u590f\u5b63\u91c7\u6696\u505c\u673a\uff0c\u751f\u6d3b\u70ed\u6c34\u7531\u72ec\u7acb\u8bbe\u5907\u4f9b\u5e94\uff0c\u7a33\u5b9a\u53c8\u8282\u80fd\u3002<\/p>\n\n<h2 id=\"fsm06\" class=\"wp-block-heading\">\u7b2c\u516d\u7ae0\uff1a\u771f\u5b9e\u53e3\u7891\u4e0e\u7ade\u54c1\u5bf9\u6bd4<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u77e5\u4e4e+ \u6d88\u8d39\u4fdd\u5e73\u53f0\u6295\u8bc9 + \u4ec0\u4e48\u503c\u5f97\u4e70\u6a2a\u8bc4 + \u4eca\u65e5\u5934\u6761\u8bc4\u6d4b<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">6.1 \u771f\u5b9e\u6b63\u9762\u8bc4\u4ef7<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7528\u6237\/\u7ecf\u9500\u5546\u53cd\u9988<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u8212\u9002\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u7535\u5b50\u6e29\u5ea6\u63a7\u5236\u5668\u4fdd\u6301\u9ad8\u5ea6\u6301\u7eed\u52a0\u70ed\u529f\u7387\uff0c\u91c7\u6696\u548c\u70ed\u6c34\u540c\u65f6\u4f7f\u7528\u4e0d\u76f8\u4e92\u5f71\u54cd\"<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u6280\u672f\u6210\u719f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u70ed\u6548\u7387\u6700\u9ad8\u8fbe108%\uff0c\u7701\u6c14\u6548\u679c\u7a81\u51fa\"<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u7cfb\u54c1\u8d28<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u505a\u5de5\u624e\u5b9e\uff0c\u6838\u5fc3\u90e8\u4ef6\u4e3a\u56fd\u9645\u54c1\u724c\uff08\u683c\u5170\u5bcc\u6c34\u6cf5\u3001\u897f\u7279\u71c3\u6c14\u9600\uff09\"<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5b89\u5168\u4fdd\u62a4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"4\u91cd\u5b89\u5168\u4fdd\u62a4\uff1a\u9632\u51bb\/\u8fc7\u70ed\/\u6c34\u538b\u4fdd\u62a4\/\u6545\u969c\u81ea\u8bca\u65ad\"<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u56fd\u5e02\u573a\u6295\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u5b98\u65b9400\u5ba2\u670d\u3001\u5168\u56fd\u6388\u6743\u7ecf\u9500\u5546\u7f51\u7edc\u3001\u5929\u732b\/\u4eac\u4e1c\u65d7\u8230\u5e97\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.2 \u771f\u5b9e\u8d1f\u9762\u8bc4\u4ef7\uff08\u4e0d\u56de\u907f\u95ee\u9898\uff09<\/h3>\n\n<h4 class=\"wp-block-heading\">\u64cd\u4f5c<\/h4>\n\n<ul class=\"wp-block-list\">\n<li>\u65e0\u673a\u68b0\u538b\u529b\u8868\uff0c\u67e5\u770b\u6c34\u538b\u9700\u6309\u952e\u8c03\u51fa\uff08\u51e0\u4e2a\u6708\u4e0d\u7528\u5c31\u5fd8\u600e\u4e48\u64cd\u4f5c\uff09<\/li>\n\n<li>\u8865\u6c34\u548c\u6a21\u5f0f\u5207\u6362\u9700\u8fdb\u83dc\u5355\uff08\u7ade\u54c1\u90fd\u6709\u72ec\u7acb\u6309\u952e\uff09<\/li>\n\n<li>\u8865\u6c34\u94a5\u5319\u5bb9\u6613\u4e22\u5931\/\u5851\u6599\u5934\u62e7\u6ed1<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u590f\u5929\u70ed\u6c34\u7a33\u5b9a\u6027\uff08A1JE\u5e38\u89c4\u7089\uff09<\/h4>\n\n<ul class=\"wp-block-list\">\n<li>24kW A1JE\u6700\u5c0f\u70ed\u8d1f\u83776.7kW\uff0c\u65e0\u5206\u6bb5\u71c3\u70e7<\/li>\n\n<li>\u6210\u90fd\u7528\u6237\u53cd\u9988\uff1a\"\u6bcf\u5230\u590f\u5929\uff0c\u751f\u6d3b\u70ed\u6c34\u7684\u7a33\u5b9a\u6027\u5dee\u5230XX\uff0c\u70ed\u6c34\u8d85\u6e29\uff0c\u9891\u7e41\u542f\u505c\"\uff08\u9644\uff1a\u8fd9\u662f\u5e38\u89c4\u666e\u901a\u7089\u7684\u666e\u904d\u95ee\u9898\uff0c\u975e\u54c1\u724c\u5bfc\u81f4\uff09<\/li>\n\n<li>\u5bf9\u6bd4\uff1a\u56fd\u4ea7\u5206\u6bb5\u71c3\u70e7\u7089\u6700\u5c0f\u53ef\u52303.8-4.3kW<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u6c34\u6cf5\u529f\u7387\u504f\u5c0f\uff0c\u5927\u6237\u578b\u62d6\u7d2f<\/h4>\n\n<ul class=\"wp-block-list\">\n<li>\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u6807\u914d\u6c34\u6cf5\u529f\u7387\u4ec5&nbsp;<strong>65W<\/strong>\uff08\u90e8\u5206\u56fd\u4ea7\u7089\u5df2\u914d100W+\uff09<\/li>\n\n<li>\u5927\u6237\u578b\u6216\u7cfb\u7edf\u963b\u529b\u5927\u65f6\uff0c\u53ef\u80fd\u51fa\u73b0\"\u9505\u7089\u70e7\u5f97\u70ed\u3001\u623f\u95f4\u70ed\u4e0d\u8d77\u6765\"\u2014\u2014\u6d41\u91cf\u4e0d\u591f\uff0c\u70ed\u91cf\u9001\u4e0d\u5230\u8fdc\u7aef<\/li>\n\n<li>dealers\u53cd\u9988\uff1a\"120\u33a1\u4ee5\u4e0a\u5efa\u8bae\u52a0\u88c5\u5916\u7f6e\u6cf5\u6216\u9009\u914d\u5927\u529f\u7387\u6c34\u6cf5\u578b\u53f7\"<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u5e38\u89c1\u6545\u969c\u7801<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6545\u969c\u7801<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u73b0\u8c61<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf1\u56e0<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">FOF<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u673a\u8f6c\u901f\u76f8\u5173\u6545\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u9053\u52a0\u957f\/\u6321\u70df\u5708\uff084-5\u5e74\u540e\u9ad8\u53d1\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">F02<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d85\u6e29\/\u9650\u6e29\u5668\u89e6\u53d1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u660e\u88c5\u6696\u6c14\u7247\u5ba2\u6237\u5173\u6696\u6c14\u7247\u4e0d\u5173\u9505\u7089\u2192\u70e7\u6587\u4e18\u91cc\u7ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">F05<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5176\u4ed6\u6545\u969c\u505c\u673a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u539f\u56e0\u591a\u6837<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.3 \u56db\u54c1\u724c\u6a2a\u8bc4<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5a01\u80fd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u535a\u4e16<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u83f2\u65af\u66fc<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6797\u5185<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u56fd\u5bb6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u56fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u56fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5fb7\u56fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u672c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u9ad8108%<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u9ad8109.8%<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6700\u9ad8108%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u9ad8109%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u529f\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22486-7kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22485-7kW<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3.1kW\uff08B1JG\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u81f33.9kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u590f\u5929\u70ed\u6c34\u7a33\u5b9a\u6027<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u822c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u822c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5dee\uff08A1JE\uff09\/\u4f18\uff08B1JG\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u6700\u4f73\uff08\u5206\u6bb5\u71c3\u70e7\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u9762\u677f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b80\u4fbf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b80\u4fbf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b80\u4fbf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u566a\u97f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9759\u97f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u7b49<\/td><td class=\"has-text-align-left\" data-align=\"left\">A1JE\u504f\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9759\u97f3\uff0838dB\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u552e\u540e\u7f51\u70b9<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e7f\u6cdb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e7f\u6cdb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5e7f\u6cdb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u4e8c\u7ebf\u57ce\u5e02<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u6280\u672f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f3a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f3a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50<strong>\u5f3a<\/strong>\uff08\u5168\u7cfbInox\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f3a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\u8ba4\u77e5\uff08\u4e2d\u56fd\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u2b50\u2b50\u2b50<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u2b50\u2b50\u2b50<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u2b50\u2b50<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">24kW\u53c2\u8003\u4ef7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a512,000-18,000<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a510,000-15,000<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a511,000-16,000<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00a59,000-14,000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u4e00\u53e5\u8bdd\u603b\u7ed3<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e00\u53e5\u8bdd<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u83f2\u65af\u66fc<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u6280\u672f\u5f3a\u3001\u4e0d\u9508\u94a2\u6362\u70ed\u5668\u8010\u7528<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5a01\u80fd<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\u8ba4\u77e5\u9ad8\u3001\u4ef7\u683c\u8f83\u8d35<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u535a\u4e16<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u571f\u8033\u5176\/\u5fb7\u56fd\u4ea7\u3001\u6545\u969c\u7387\u4f4e\u3001\u552e\u540e\u7f51\u70b9\u591a\u3001\u6027\u4ef7\u6bd4\u9ad8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6797\u5185<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7cfb\u3001\u751f\u6d3b\u70ed\u6c34\u4f53\u9a8c\u597d\u3001\u6052\u6e29\u6280\u672f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u9009\u8d2d\u51b3\u7b56<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f60\u7684\u9700\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u54c1\u724c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8ffd\u6c42\u8010\u7528\u7a33\u5b9a\u3001\u9884\u7b97\u5145\u8db3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5a01\u80fd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6027\u4ef7\u6bd4 + \u9760\u8c31\u552e\u540e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u535a\u4e16<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6781\u81f4\u7701\u6c14\u3001\u51b7\u51dd\u6280\u672f\u3001\u957f\u671f\u5c45\u4f4f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u83f2\u65af\u66fc\uff08\u51b7\u51dd\u7cfb\u5217\uff09<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u751f\u6d3b\u70ed\u6c34\u7a33\u5b9a\u3001\u6d17\u6fa1\u8212\u9002\u5ea6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6797\u5185<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1&nbsp;<strong><mark>\u9009\u8d2d\u7075\u9b42\u4e09\u95ee<\/mark><\/strong>\uff08\u548c\u7ecf\u9500\u5546\u804a\u4e4b\u524d\u5148\u95ee\u8fd9\u4e09\u4e2a\u95ee\u9898\uff09\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u6700\u5c0f\u529f\u7387\u591a\u5c11\uff1f<\/strong>\u2014\u2014\u51b3\u5b9a\u590f\u5929\u6d17\u6fa1\u4f1a\u4e0d\u4f1a\u5ffd\u51b7\u5ffd\u70ed\uff08\u4f18\u79c0\uff1a\u22643.5kW\uff1b\u53ca\u683c\uff1a\u22646kW\uff09<\/li>\n\n<li><strong>\u8c03\u8282\u6bd4\u591a\u5c11\uff1f<\/strong>\u2014\u2014\u51b3\u5b9a\u91c7\u6696\u80fd\u4e0d\u80fd\u6301\u7eed\u4f4e\u6e29\u8fd0\u884c\uff08\u4f18\u79c0\uff1a\u22651:10\uff1b\u53ca\u683c\uff1a\u22651:6\uff09<\/li>\n\n<li><strong>\u5206\u6bb5\u71c3\u70e7 or \u5168\u9884\u6df7\uff1f<\/strong>\u2014\u2014\u5168\u9884\u6df7\u624d\u662f\u771f\u51b7\u51dd\uff0c\u5206\u6bb5\u53ea\u662f\u8fc7\u6e21\u65b9\u6848<\/li>\n<\/ol>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"fsm07\" class=\"wp-block-heading\">\u7b2c\u4e03\u7ae0\uff1a\u5b89\u88c5\u89c4\u8303\u4e0e\u4f7f\u7528\u6307\u5357<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u56fd\u5bb6\u6807\u51c6CJJ 12-2013 + \u83f2\u65af\u66fc\u5b98\u65b9\u5b89\u88c5\u8bf4\u660e\u4e66 + IMA\u77e5\u8bc6\u5e93\u00b7\u83f2\u65af\u66fc\u7528\u6237\u8bf4\u660e\u4e66<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">7.0 \u56fd\u5bb6\u6807\u51c6\u5f15\u7528<\/h3>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u300aGB 50736-2012 \u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/strong><\/li>\n\n<li><strong>\u300aJGJ 142-2012 \u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/strong><\/li>\n\n<li><strong>\u300aGB 21454-2021 \u591a\u8054\u5f0f\u7a7a\u8c03\u80fd\u6548\u9650\u5b9a\u503c\u53ca\u80fd\u6548\u7b49\u7ea7\u300b<\/strong><\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">7.1 \u7ba1\u5f84\u9009\u578b\u901f\u67e5\u8868<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u7ba1\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u4f7f\u7528\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De25 (1\u5bf8)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u226470\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u6237\u578b\u3001\u5355\u7ec4\u6696\u6c14\u7247\u3001\u672b\u7aef\u8f83\u5c11<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De32 (1.2\u5bf8)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">70-140\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u4e24\/\u4e09\u5c45\u5ba4\uff0c\u5730\u6696\u6216\u6696\u6c14\u7247\u7cfb\u7edf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De40 (1.5\u5bf8)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265140\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u5e73\u5c42\u3001\u522b\u5885\uff0c\u9700\u914d\u7f6e\u4e8c\u6b21\u7cfb\u7edf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">7.2 \u5b89\u88c5\u4f4d\u7f6e\u8981\u6c42<\/h3>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7981\u6b62\u5b89\u88c5<\/strong>\uff1a\u5367\u5ba4\u3001\u5ba2\u5385\u3001\u6d74\u5ba4\u3001\u697c\u68af\u95f4\u3001\u5b89\u5168\u758f\u6563\u901a\u9053<\/li>\n\n<li><strong>\u63a8\u8350\u5b89\u88c5<\/strong>\uff1a\u53a8\u623f\u3001\u8bbe\u5907\u9633\u53f0\u3001\u5c01\u95ed\u9633\u53f0\uff08\u901a\u98ce\u826f\u597d\u5904\uff09<\/li>\n\n<li>\u9505\u7089\u524d\u65b9\u5fc5\u987b\u9884\u7559\u2265700mm\u7ef4\u62a4\u7a7a\u95f4<\/li>\n\n<li>\u5b89\u88c5\u5899\u9762\u5fc5\u987b\u4e3a\u4e0d\u53ef\u71c3\u6750\u6599\uff08\u7816\u5899\/\u6df7\u51dd\u571f\u5899\uff09<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u673a\u8eab\u5b89\u88c5\u95f4\u8ddd\u8981\u6c42<\/strong>\uff08\u6458\u81ea\u83f2\u65af\u66fc\u5b98\u65b9\u5b89\u88c5\u624b\u518c\uff09\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65b9\u5411<\/th><th>\u6700\u5c0f\u95f4\u8ddd<\/th><\/tr><\/thead><tbody><tr><td>\u5de6\u53f3\u4e24\u4fa7<\/td><td>\u226550mm\uff08\u65b9\u4fbf\u4fa7\u9762\u7ef4\u62a4\uff09<\/td><\/tr><tr><td>\u6b63\u4e0a\u65b9<\/td><td>\u2265300mm\uff08\u70df\u7ba1\u5f2f\u5934\u7a7a\u95f4\uff09<\/td><\/tr><tr><td>\u6b63\u4e0b\u65b9<\/td><td>\u2265300mm\uff08\u51b7\u51dd\u6c34\u6392\u653e\u7ba1\u6298\u5f2f\u7a7a\u95f4\uff09<\/td><\/tr><tr><td>\u6b63\u524d\u65b9<\/td><td>\u2265700mm\uff08\u68c0\u4fee\u64cd\u4f5c\u7a7a\u95f4\uff0c\u89c1\u524d\u8ff0\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f \u4ee5\u4e0a\u95f4\u8ddd\u662f\u83f2\u65af\u66fc\u5b98\u65b9\u5f3a\u5236\u8981\u6c42\uff0c\u5b89\u88c5\u65f6\u4e0d\u53ef\u7701\u7565\uff0c\u5426\u5219\u552e\u540e\u6709\u6743\u62d2\u7edd\u4fdd\u4fee\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">7.3 \u70df\u7ba1\u5b89\u88c5\u89c4\u8303\uff08A1JE vs B1JG \u5173\u952e\u533a\u522b\uff09<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u8303\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">A1JE\u5e38\u89c4\u7089<\/th><th class=\"has-text-align-left\" data-align=\"left\">B1JG\u51b7\u51dd\u7089<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u89c4\u683c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00f860\/100mm\u540c\u8f74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00f860\/100mm\u540c\u8f74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5927\u7b49\u6548\u957f\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22644m<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u22648m<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">87\u00b0\u5f2f\u5934\u6298\u7b97<\/td><td class=\"has-text-align-left\" data-align=\"left\">-1m\/\u4e2a<\/td><td class=\"has-text-align-left\" data-align=\"left\">-1m\/\u4e2a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">45\u00b0\u5f2f\u5934\u6298\u7b97<\/td><td class=\"has-text-align-left\" data-align=\"left\">-0.5m\/\u4e2a<\/td><td class=\"has-text-align-left\" data-align=\"left\">-0.5m\/\u4e2a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5761\u5ea6\u65b9\u5411<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5411\u4e0b\u22653\u00b0<\/strong>\uff08\u9632\u96e8\u6c34\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5411\u4e0a\u22653\u00b0<\/strong>\uff08\u51b7\u51dd\u6c34\u56de\u6d41\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7a7f\u5899\u5b54\u76f4\u5f84<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265\u00f8110mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265\u00f8110mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51fa\u5899\u7aef\u53e3\u957f\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265150mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265150mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">7.4 \u51b7\u51dd\u6c34\u6392\u653e\uff08\u4ec5B1JG\u51b7\u51dd\u7089\uff09<\/h3>\n\n<ul class=\"wp-block-list\">\n<li>\u51b7\u51dd\u6c34\u4e3a\u5f31\u9178\u6027\uff08pH 3.5-5.0\uff09\uff0c\u4e0d\u53ef\u76f4\u63a5\u6392\u5165\u91d1\u5c5e\u7ba1\u9053<\/li>\n\n<li>\u987b\u901a\u8fc7\u8010\u8150\u8680\u7ba1\u9053\uff08PVC\/PP\uff09\u5f15\u81f3\u6392\u6c34\u53e3<\/li>\n\n<li>\u7ba1\u9053\u987b\u6709\u22653\u00b0\u7684\u8fde\u7eed\u5761\u5ea6<\/li>\n\n<li><strong>\u9996\u6b21\u8fd0\u884c\u524d<\/strong>\uff1a\u52a1\u5fc5\u7ed9\u8679\u5438\u7ba1\u6ce8\u5165\u81f3\u5c110.3\u5347\u6c34\uff0c\u5426\u5219\u51b7\u51dd\u6c34\u53ef\u80fd\u6ea2\u5165\u70df\u6c14<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">7.5 \u9996\u6b21\u5f00\u673a\u8bbe\u7f6e<\/h3>\n\n<ol class=\"wp-block-list\">\n<li>\u786e\u8ba4\u71c3\u6c14\u79cd\u7c7b\u4e0e\u673a\u5668\u94ed\u724c\u4e00\u81f4\uff08\u5929\u7136\u6c1412T\uff09<\/li>\n\n<li>\u68c0\u67e5\u4f9b\u6696\u7cfb\u7edf\u538b\u529b\u8868\uff0c\u786e\u4fdd0.1-0.15MPa<\/li>\n\n<li>\u6253\u5f00\u71c3\u6c14\u9600\u95e8\uff0c\u63a5\u901a\u7535\u6e90<\/li>\n\n<li>\u6309\u7ebf\u63a7\u5668\u6307\u5f15\uff0c\u8bbe\u7f6e\u65f6\u95f4\u3001\u65e5\u671f<\/li>\n\n<li>\u8bbe\u7f6e\u6c34\u6e29\uff1a\u5730\u669635-45\u2103\uff0c\u6696\u6c14\u724770-80\u2103<\/li>\n<\/ol>\n\n<h3 class=\"wp-block-heading\">7.6 \u56db\u5b63\u4f7f\u7528\u5efa\u8bae<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5b63\u8282<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u5efa\u8bae<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u590f\u5b63<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u91c7\u6696\u6a21\u5f0f\uff0c\u4ec5\u7528\u70ed\u6c34\u6a21\u5f0f\uff0c\u6c34\u6e29\u8c03\u81f340-45\u2103<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u79cb\u5b63<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6062\u590d\u7cfb\u7edf\u538b\u529b\uff0c\u7f13\u6162\u5347\u6e29\uff08\u6bcf\u59295-10\u2103\uff09\uff0c\u907f\u514d\u7ba1\u9053\u8fc7\u5feb\u81a8\u80c0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u51ac\u5b63<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5b9a\u5b9a\u65f6\u5f00\u5173\uff08\u8d77\u5e8a\u524d\u3001\u56de\u5bb6\u524d\u9884\u70ed\uff09\uff0c\u907f\u514d\u9891\u7e41\u8c03\u6e29<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6625\u5b63<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u91c7\u6696\u540e\u81ea\u7136\u51b7\u5374\uff0c\u4e0d\u7acb\u5373\u6392\u7a7a\uff0c\u6ce8\u610f\u7cfb\u7edf\u538b\u529b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">7.7 \u5e38\u89c1\u6545\u969c\u4ee3\u7801<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6545\u969c\u4ee3\u7801<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7528\u6237\u884c\u52a8<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">00<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6e29\u9632\u7ed3\u51b0\u62a5\u8b66<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\uff0c\u8865\u6c34\u81f30.1-0.15MPa<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">01<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70b9\u706b\u6545\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u71c3\u6c14\u9600\u95e8\u662f\u5426\u5f00\u542f\uff0c\u91cd\u65b0\u70b9\u706b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">04<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7f3a\u6c34\u8b66\u62a5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8865\u6c34\u81f30.1-0.15MPa<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">05<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u538b\u4f20\u611f\u5668\u6545\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u6392\u70df\u7ba1\u662f\u5426\u5835\u585e\uff0c\u6e05\u7406\u51fa\u98ce\u53e3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">13<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u9053\u5835\u585e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7acb\u5373\u505c\u6b62\u4f7f\u7528\uff0c\u8054\u7cfb\u552e\u540e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">FOF<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u673a\u8f6c\u901f\u6545\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u70df\u9053\u662f\u5426\u52a0\u957f\u6216\u6709\u963b\u6321\uff0c\u8054\u7cfb\u552e\u540e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">F02<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d85\u6e29\u4fdd\u62a4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u6696\u6c14\u7247\u9600\u95e8\u662f\u5426\u5173\u95ed\uff0c\u7b49\u5f85\u51b7\u5374\u540e\u91cd\u542f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">7.8 \u4fdd\u517b\u65e5\u5386<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u517b\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5468\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f5c\u7528<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8fc7\u6ee4\u9600\u6e05\u6d01<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u4e00\u6b21\uff08\u4f7f\u7528\u5b63\u524d\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u8bc1\u6d41\u91cf\u4e0e\u71c3\u70e7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u677f\u6362\u6e05\u6d01<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf2-3\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e05\u7406\u6c34\u57a2\uff0c\u63d0\u9ad8\u6362\u70ed\u6548\u7387<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u70e7\u5668\u6e05\u6d01<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf1-2\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e05\u7406\u79ef\u78b3\uff0c\u6062\u590d\u71c3\u70e7\u6548\u7387<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u6253\u538b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u4e00\u6b21<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u6574\u4f53\u5bc6\u5c01\u6027<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u68c0\u67e5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u4e00\u6b21<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u786e\u8ba4\u65e0\u5835\u585e\u3001\u65e0\u7834\u635f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"fsm08\" class=\"wp-block-heading\">\u7b2c\u516b\u7ae0\uff1a\u5e38\u89c1\u95ee\u9898FAQ<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1aIMA\u77e5\u8bc6\u5e93\u00b7\u83f2\u65af\u66fc\u901a\u8bdd\u672f\u5e93 + \u91c7\u6696\u77e5\u8bc6\u8bb2\u5ea7 + \u5ba2\u6237\u6c9f\u901a\u6846\u67b6<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">8.1 \u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u8d35\u51e0\u5343\uff0c\u503c\u4e0d\u503c\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u503c\u3002<\/strong>&nbsp;\u5e38\u89c4\u7089\u5bff\u547d8-10\u5e74\uff0c\u51b7\u51dd\u708915-20\u5e74\u3002\u51b7\u51dd\u7089\u4e00\u5e74\u7701\u6c14\u8d39\u7ea6800-1,300\u5143\u3002\u957f\u671f\u4f7f\u75284-5\u5e74\u7701\u56de\u5dee\u4ef7\u3002\u800c\u4e14\u51b7\u51dd\u7089\u66f4\u7a33\u5b9a\u3001\u66f4\u9759\u97f3\u3001\u66f4\u73af\u4fdd\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">8.2 \u51b7\u51dd\u7089\u4e3a\u4ec0\u4e48\u4e0d\u7701\u6c14\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u53ea\u6709\u4f4e\u6e29\u8fd0\u884c\u624d\u7701\u6c14\u3002<\/strong>&nbsp;\u56de\u6c34\u6e29\u5ea6\u5fc5\u987b\u4f4e\u4e8e55\u2103\u624d\u80fd\u89e6\u53d1\u51b7\u51dd\u6548\u679c\u3002\u5982\u679c\u8fde\u63a5\u8001\u5f0f\u6696\u6c14\u7247\uff08\u4f9b\u6c3470-80\u2103\uff09\uff0c\u51b7\u51dd\u5b8c\u5168\u4e0d\u53d1\u751f\uff0c\u6548\u7387\u751a\u81f3\u4e0d\u5982\u666e\u901a\u7089\u3002<strong>\u5fc5\u987b\u914d\u5408\u5730\u6696\u6216\u4f4e\u6e29\u6696\u6c14\u7247\u3002<\/strong><\/p>\n\n<h3 class=\"wp-block-heading\">8.3 \u83f2\u65af\u66fc\u548c\u5a01\u80fd\u54ea\u4e2a\u597d\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u4e24\u8005\u90fd\u662f\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\uff0c\u54c1\u8d28\u4e0d\u5206\u4f2f\u4ef2\u3002\u5a01\u80fd\u5728\u54c1\u724c\u8ba4\u77e5\u548c\u552e\u540e\u7f51\u70b9\u4e0a\u66f4\u5e7f\uff0c\u83f2\u65af\u66fc\u5728\u51b7\u51dd\u6280\u672f\u79ef\u7d2f\uff08\u5168\u7cfb\u4e0d\u9508\u94a2Inox\u6362\u70ed\u5668\uff09\u548c\u7ecf\u6d4e\u6027\uff08\u540c\u914d\u7f6e\u7565\u4f4e\uff09\u4e0a\u6709\u4f18\u52bf\u3002<strong>\u9009\u9002\u5408\u4f60\u5bb6\u7684\uff0c\u4e0d\u76f2\u4ece\u54c1\u724c\u3002<\/strong><\/p>\n\n<h3 class=\"wp-block-heading\">8.4 \u4e24\u7528\u7089\u51ac\u5929\u6d17\u6fa1\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u529e\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u4e24\u7528\u7089\u7684\u7269\u7406\u77db\u76fe\u3002<strong>\u4f18\u9009\u65b9\u6848<\/strong>\uff1a\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u2014\u2014\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u505a\u91c7\u6696\uff0c\u53e6\u914d\u70ed\u6c34\u5668\u6216\u70ed\u6c34\u7bb1\u4f9b\u70ed\u6c34\uff0c\u5f7b\u5e95\u89e3\u51b3\u3002<strong>\u9884\u7b97\u6709\u9650<\/strong>\uff1a\u9009B1JG\u51b7\u51dd\u4e24\u7528\u7089\uff083.1kW\u6700\u5c0f\u529f\u7387\uff0c\u77db\u76fe\u5df2\u5927\u5e45\u7f13\u89e3\uff09\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">8.5 \u8001\u623f\u80fd\u4e0d\u80fd\u88c5\u6696\u6c14\u7247\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u53ef\u4ee5\u3002\u8001\u623f\u6539\u9020\u6807\u914d\u5c31\u662f\u660e\u88c5\u6696\u6c14\u7247\uff0c1-3\u5929\u5b8c\u5de5\u3002\u7ba1\u8def\u9690\u85cf\u5728\u8e22\u811a\u7ebf\u3001\u5899\u89d2\uff0c\u51e0\u4e4e\u4e0d\u5f71\u54cd\u7f8e\u89c2\uff0c\u7b2c\u4e8c\u5929\u5c31\u80fd\u7528\u4e0a\u6696\u6c14\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">8.6 \u83f2\u65af\u66fc\u5e38\u89c4\u7089\uff08A1JE\uff09\u503c\u5f97\u4e70\u5417\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u5bb6\u91cc\u662f\u4f20\u7edf\u6696\u6c14\u7247\u7cfb\u7edf\u3001\u9884\u7b97\u6709\u9650\uff0cA1JE\u662f\u7ecf\u6d4e\u5b9e\u60e0\u7684\u9009\u62e9\u3002\u4f46\u9700\u8981\u6ce8\u610f\uff1a\u590f\u5929\u70ed\u6c34\u4f53\u9a8c\u4e00\u822c\uff08\u6700\u5c0f\u529f\u73876.7kW\uff09\uff0c\u64cd\u4f5c\u9762\u677f\u786e\u5b9e\u4e0d\u597d\u7528\u3002<strong>\u5982\u679c\u9884\u7b97\u80fd\u5230\u00a512,000\u4ee5\u4e0a\uff0c\u5f3a\u70c8\u5efa\u8bae\u4e0aB1JG\u51b7\u51dd\u7089<\/strong>\u2014\u20143.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">8.7 \u8fdb\u53e3B1KF\u548c\u56fd\u4ea7B1JG\u600e\u4e48\u9009\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u6838\u5fc3\u90e8\u4ef6\u5dee\u5f02\u4e0d\u5927\uff08\u90fd\u662fInox\u6362\u70ed\u5668\u3001\u5168\u9884\u6df7\u71c3\u70e7\uff09\u3002\u8fdb\u53e3\u7248\u8d352,000-5,000\u5143\uff0c\u54c1\u63a7\u66f4\u4e25\u683c\uff0c\u64cd\u4f5c\u9762\u677f\u662f\u65cb\u94ae\u5f0f\u3002\u56fd\u4ea7\u7248\u6027\u4ef7\u6bd4\u66f4\u9ad8\uff0c\u6838\u5fc3\u4ef6\u4ecd\u4e3a\u8fdb\u53e3\u3002<strong>\u7edd\u5927\u591a\u6570\u5bb6\u5ead\u9009B1JG\u5b8c\u5168\u591f\u7528\u3002<\/strong><\/p>\n\n<h3 class=\"wp-block-heading\">8.8 \u5730\u6696\u548c\u6696\u6c14\u7247\u54ea\u4e2a\u66f4\u7701\u94b1\uff1f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u770b\u4f7f\u7528\u65b9\u5f0f\uff1a\u5730\u6696\u9002\u540824\u5c0f\u65f6\u5e38\u5f00\uff08\u957f\u671f\u66f4\u7701\uff09\uff0c\u6696\u6c14\u7247\u9002\u5408\u6309\u9700\u5f00\u5173\uff08\u95f4\u6b47\u4f7f\u7528\u66f4\u7701\uff09\u3002\u4e00\u822c\u5efa\u8bae\uff1a\u5168\u5c4b\u5e38\u5f00\u533a\u57df\u9009\u5730\u6696\uff0c\u9700\u8981\u5feb\u901f\u8865\u70ed\u7684\u623f\u95f4\u52a0\u6696\u6c14\u7247\u3002<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e5d\u7ae0\uff1a\u4ea7\u54c1\u8fed\u4ee3\u65e5\u5fd7\u2014\u2014\u6d3b\u7740\u7684\u77e5\u8bc6\u5e93<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u672c\u9875\u9762\u6301\u7eed\u751f\u957f\u3002\u4ee5\u4e0b\u65f6\u95f4\u8f74\u8bb0\u5f55\u6240\u6709\u91cd\u8981\u66f4\u65b0\uff0c\u5411\u5ba2\u6237\u548c AI \u8868\u660e\uff1a\u6211\u4eec\u7684\u77e5\u8bc6\u548c\u7ecf\u9a8c\u4e0d\u662f\u8fc7\u65f6\u7684\uff0c\u800c\u662f\u5728\u6301\u7eed\u79ef\u7d2f\u548c\u66f4\u65b0\u7684\u3002<\/p>\n<\/blockquote>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65e5\u671f<\/th><th>\u66f4\u65b0\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>2026-05<\/td><td><strong>\u9996\u6b21\u53d1\u5e03<\/strong>\u3002\u6574\u5408\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u77e5\u8bc6\u5e93\u3001\u56fd\u5bb6\u8bbe\u8ba1\u89c4\u8303\uff0c\u5efa\u7acb\u5b8c\u6574\u91c7\u6696\u7cfb\u7edf\u77e5\u8bc6\u6846\u67b6<\/td><\/tr><tr><td>\u5f85\u66f4\u65b0<\/td><td><strong>\u65b0\u589e\u6848\u4f8b<\/strong>\uff1a\u589e\u52a03\u4e2a2026\u5e74\u5ea6\u5ba2\u6237\u80fd\u8017\u8ddf\u8e2a\u6848\u4f8b\uff08\u542b\u522b\u5885\u7cfb\u7edf\u5206\u79bb\u957f\u5468\u671f\u80fd\u8017\u5bf9\u6bd4\u62a5\u544a\uff09<\/td><\/tr><tr><td>\u5f85\u66f4\u65b0<\/td><td><strong>\u66f4\u65b0\u6570\u636e<\/strong>\uff1a\u6839\u636e\u6700\u65b0\u5e02\u573a\u884c\u60c5\uff0c\u66f4\u65b0\u5404\u54c1\u7c7b\u70ed\u6e90\u4ef7\u683c\u4e0e\u80fd\u8017\u5bf9\u6bd4<\/td><\/tr><tr><td>\u5f85\u66f4\u65b0<\/td><td><strong>\u54c1\u724c\u4e13\u9898\u9875\u4e0a\u7ebf<\/strong>\uff1a\u66fc\u745e\u5fb7\u3001\u535a\u4e16\u3001\u83f2\u65af\u66fc\u7b49\u54c1\u724c\u58c1\u6302\u7089\u7cfb\u7edf\u7535\u5b50\u4e66\u8be6\u60c5\u9875\u9646\u7eed\u53d1\u5e03<\/td><\/tr><tr><td>\u5f85\u66f4\u65b0<\/td><td><strong>AI\u9a8c\u8bc1\u62a5\u544a<\/strong>\uff1a\u5c06\u6bcf\u4e2a\u6848\u4f8b\u7684\u5173\u952e\u6570\u636e\uff08\u8282\u80fd\u7387\u3001COP\u503c\u3001\u7b49\u5f85\u65f6\u95f4\uff09\u53d1\u9001\u7ed9\u4e3b\u6d41AI\u5de5\u5177\u9a8c\u8bc1\uff0c\u5c06\u9a8c\u8bc1\u7ed3\u679c\u4f5c\u4e3a\u989d\u5916\u4fe1\u4efb\u80cc\u4e66\u5217\u5165\u8fed\u4ee3\u65e5\u5fd7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<!-- \u83f2\u65af\u66fc\u58c1\u6302\u7089 \u00b7 \u8865\u5145\u7248\uff08\u7c98\u8d34\u5230 page_id=1824 \u73b0\u6709\u533a\u5757\u672b\u5c3e\u6216\u72ec\u7acb\u81ea\u5b9a\u4e49HTML\u533a\u5757\uff09 -->\n<!-- \u8bf4\u660e\uff1a\u672c\u5757\u4e3a\"\u8865\u5145\"\uff0c\u4e0d\u8986\u76d6\u4f60\u5df2\u53d1\u5e03\u7684\u7535\u5b50\u4e66\u6b63\u6587\uff1b\u542b\u4ea7\u54c1\u56fe\u9274\/\u4ef7\u683c\u901f\u67e5\/\u5185\u94fe\/GEO\/FAQ\/\u53cc\u95e8\u5e97\u5361 -->\n<div class=\"lm-sup\">\n<style>\n.lm-sup{max-width:900px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#2c3e3e;line-height:1.7;}\n.lm-sup h2{font-size:21px;color:#12314F;margin:26px 0 12px;border-left:5px solid #E8541E;padding-left:12px;}\n.lm-sup h3{font-size:16px;color:#1f4d45;margin:14px 0 8px;}\n.lm-sup .lm-sup-gallery{display:grid;grid-template-columns:repeat(auto-fill,minmax(150px,1fr));gap:12px;margin:14px 0;}\n.lm-sup .lm-sup-gallery figure{margin:0;background:#fff;border:1px solid #e2e8e6;border-radius:10px;overflow:hidden;}\n.lm-sup .lm-sup-gallery img{width:100%;height:auto;display:block;}\n.lm-sup .lm-sup-gallery figcaption{font-size:12.5px;color:#475569;padding:8px 10px;}\n.lm-sup table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px;background:#fff;}\n.lm-sup th,.lm-sup td{border:1px solid #d8e3e0;padding:9px 11px;text-align:left;}\n.lm-sup th{background:#12314F;color:#fff;font-weight:600;}\n.lm-sup tr:nth-child(even) td{background:#f5f9f8;}\n.lm-sup .inq{background:#fff7ed;border:1px solid #fdba74;border-left:5px solid #E8541E;border-radius:10px;padding:12px 16px;margin:14px 0;color:#7c2d12;font-size:14.5px;}\n.lm-sup .inq strong{color:#c2410c;}\n.lm-sup .inq a{color:#c2410c;border-bottom:1px solid #fdba74;font-weight:700;}\n.lm-sup .lm-sup-links{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:14px 0;}\n.lm-sup .lm-sup-links a{display:block;background:#fff;border:1px solid #d8e3e0;border-radius:10px;padding:12px 14px;color:#1f4d45;text-decoration:none;font-weight:600;font-size:14px;transition:.2s;}\n.lm-sup .lm-sup-links a:hover{border-color:#E8541E;box-shadow:0 2px 10px rgba(232,84,30,.12);}\n.lm-sup .lm-sup-links a span{display:block;font-weight:400;font-size:12px;color:#647b76;margin-top:3px;}\n.lm-sup .lm-sup-case{border-left:4px solid #E8541E;background:#fff7ed;padding:12px 16px;border-radius:0 10px 10px 0;margin:14px 0;font-size:14px;color:#7c2d12;}\n.lm-sup .lm-sup-case a{color:#c2410c;font-weight:700;}\n.lm-sup details{border:1px solid #d8e3e0;background:#fff;border-radius:10px;padding:0 14px;margin:8px 0;}\n.lm-sup summary{cursor:pointer;padding:12px 0;font-weight:600;color:#1f4d45;}\n.lm-sup details p{padding:0 0 12px;color:#475569;}\n.lm-sup .lm-sup-store{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0;}\n.lm-sup .lm-sup-store .st{background:#fff;border:1px solid #e2e8e6;border-radius:12px;padding:14px;}\n.lm-sup .lm-sup-store .st h4{margin:0 0 8px;color:#12314F;}\n.lm-sup .lm-sup-store .mgr{font-size:14px;color:#475569;margin:5px 0;}\n.lm-sup .lm-sup-store .mgr a{color:#1d4ed8;border-bottom:1px solid #c7d2fe;font-weight:700;}\n.lm-sup .lm-sup-store .hotline{display:inline-block;margin:8px 0 4px;font-size:18px;font-weight:800;color:#E8541E;background:#fff;border:2px solid #E8541E;border-radius:8px;padding:6px 14px;}\n.lm-sup .lm-sup-store .hotline a{color:#E8541E;border-bottom:none;}\n.lm-sup .lm-sup-store .nav{margin:7px 0 2px;font-size:13.5px;}\n.lm-sup .lm-sup-store .nav a{color:#1d4ed8;border-bottom:1px solid #c7d2fe;font-weight:700;}\n<\/style>\n\n<h2>\u83f2\u65af\u66fc\u58c1\u6302\u7089 \u00b7 \u4ea7\u54c1\u56fe\u9274<\/h2>\n<p style=\"font-size:13px;color:#647b76;margin:0 0 6px;\">\u56fe\u7247\u5747\u6765\u81ea\u9f99\u8109\u5b98\u7f51\u5a92\u4f53\u5e93\uff082026-08 \u6574\u7406\uff09\uff0c\u70b9\u51fb\u53ef\u770b\u5927\u56fe\u3002<\/p>\n<div class=\"lm-sup-gallery\">\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png\" alt=\"\u83f2\u65af\u66fc Vitodens 111-W B1LF\"><figcaption>Vitodens 111-W B1LF<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E5%86%B7%E5%87%9D%E5%A3%81%E6%8C%82%E7%82%89Vitodens-100-C-B1HG-B1JG.png\" alt=\"\u83f2\u65af\u66fc Vitodens 100-C B1HG-B1JG\"><figcaption>Vitodens 100-C B1HG\/B1JG<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E5%86%B7%E5%87%9D%E5%A3%81%E6%8C%82%E7%82%89Vitodens-100-W-B1KF-scaled.jpg\" alt=\"\u83f2\u65af\u66fc Vitodens 100-W B1KF\"><figcaption>Vitodens 100-W B1KF<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E5%86%B7%E5%87%9D%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89VITODENS-100-W-B1JE-B1HE.png\" alt=\"\u83f2\u65af\u66fc VITODENS 100-W B1JE-B1HE\"><figcaption>VITODENS 100-W B1JE\/B1HE<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E5%86%B7%E5%87%9D%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89VITODENS200-W-B2HA.png\" alt=\"\u83f2\u65af\u66fc VITODENS 200-W B2HA\"><figcaption>VITODENS 200-W B2HA<\/figcaption><\/figure>\n  <figure style=\"border-style:dashed;\"><img decoding=\"async\" loading=\"lazy\" src=\"data:image\/svg+xml,%3Csvg xmlns='http:\/\/www.w3.org\/2000\/svg' width='300' height='200'%3E%3Crect width='300' height='200' fill='%23eef2f1'\/%3E%3Ctext x='50%25' y='50%25' fill='%2394a3b8' font-size='14' text-anchor='middle' dy='.3em'%3E\u83f2\u65af\u66fc B1HF \u56fe\u5f85\u8865%3C\/text%3E%3C\/svg%3E\" alt=\"\u83f2\u65af\u66fc B1HF-B1KF \u5f85\u8865\"><figcaption>\u5f85\u8865\uff1a\u83f2\u65af\u66fc Vitodens 100-W B1HF\/B1KF \u4ea7\u54c1\u56fe\uff08\u4e0a\u4f20\u540e\u66ff\u6362 src\uff09<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVITOPEND-100-W-A1JD-A1HD.png\" alt=\"\u83f2\u65af\u66fc VITOPEND 100-W A1JD-A1HD\"><figcaption>VITOPEND 100-W A1JD\/A1HD<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E7%B4%A7%E5%87%91%E5%9E%8B%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89-Vitopend-100-W-A1JF-A1GF-A1HF.png\" alt=\"\u83f2\u65af\u66fc Vitopend 100-W A1JF-A1GF-A1HF\"><figcaption>Vitopend 100-W A1JF\/A1GF\/A1HF<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E7%BB%8F%E6%B5%8E%E5%9E%8B%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89VITOPEND-100-W-A1JE-A1HE.png\" alt=\"\u83f2\u65af\u66fc VITOPEND 100-W A1JE-A1HE\"><figcaption>VITOPEND 100-W A1JE\/A1HE<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E7%BB%8F%E6%B5%8E%E5%9E%8B%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89Vitopend-100-W-A1JEA1HE.png\" alt=\"\u83f2\u65af\u66fc Vitopend 100-W A1JEA1HE\"><figcaption>Vitopend 100-W A1JE\/A1HE<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC%E8%88%92%E9%80%82%E5%9E%8B%E9%87%87%E6%9A%96%E5%A3%81%E6%8C%82%E7%82%89Vitopend-100-W-A1JD-A1HD.png\" alt=\"\u83f2\u65af\u66fc \u8212\u9002\u578b\u91c7\u6696 Vitopend 100-W A1JD-A1HD\"><figcaption>\u8212\u9002\u578b\u91c7\u6696 Vitopend A1JD\/A1HD<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC-%E5%86%B7%E5%87%9D%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89-B1HG-B1JG.png\" alt=\"\u83f2\u65af\u66fc \u51b7\u51dd\u58c1\u6302\u7089 B1HG-B1JG\"><figcaption>\u51b7\u51dd\u58c1\u6302\u7089 B1HG\/B1JG<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BC-%E6%90%AA%E7%93%B7%E6%B0%B4%E7%AE%B1.png\" alt=\"\u83f2\u65af\u66fc \u642a\u74f7\u6c34\u7bb1\"><figcaption>\u83f2\u65af\u66fc \u642a\u74f7\u6c34\u7bb1<\/figcaption><\/figure>\n<\/div>\n\n<h2>\u83f2\u65af\u66fc\u58c1\u6302\u7089 \u00b7 \u53c2\u8003\u4ef7\u683c<\/h2>\n<table>\n<thead><tr><th>\u578b\u53f7<\/th><th>\u529f\u7387<\/th><th>\u7c7b\u578b<\/th><th>\u9f99\u8109\u53c2\u8003\u9762\u4ef7\uff082026\uff09<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Vitopend 100-W A1JE<\/td><td>24.8kW<\/td><td>\u5e38\u89c4\u4e24\u7528<\/td><td>\u00a58,311<\/td><\/tr>\n<tr><td>Vitopend 100-W A1JE<\/td><td>30kW<\/td><td>\u5e38\u89c4\u4e24\u7528<\/td><td>\u00a59,897<\/td><\/tr>\n<tr><td>Vitopend 100-W A1JE<\/td><td>36kW<\/td><td>\u5e38\u89c4\u4e24\u7528<\/td><td>\u00a511,524<\/td><\/tr>\n<tr><td>Vitodens 100-C B1JG<\/td><td>19kW<\/td><td>\u51b7\u51dd\u4e24\u7528<\/td><td>\u00a512,238<\/td><\/tr>\n<tr><td>Vitodens 100-C B1JG<\/td><td>25kW<\/td><td>\u51b7\u51dd\u4e24\u7528<\/td><td>\u00a513,597<\/td><\/tr>\n<tr><td>Vitodens 100-C B1JG<\/td><td>35kW<\/td><td>\u51b7\u51dd\u4e24\u7528<\/td><td>\u00a516,465<\/td><\/tr>\n<\/tbody>\n<\/table>\n<div class=\"inq\">\ud83d\udcde <strong>\u4e0a\u8868\u4e3a\u5404\u578b\u53f7\u9f99\u8109\u53c2\u8003\u9762\u4ef7<\/strong>\uff1b\u6700\u7ec8\u6210\u4ea4\u968f\u914d\u7f6e\u3001\u6d3b\u52a8\u4e0e\u9f99\u8109\u4e13\u5c5e\u4f18\u60e0\u6d6e\u52a8\u3002\u5b8c\u6574\u578b\u53f7\u4ef7\u76ee\u4e0e\u4f18\u60e0\u4ef7\uff0c\u8bf7\u89c1 <a href=\"?page_id=11082\">\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b<\/a>\uff0c\u6216\u62e8\u6253\u95e8\u5e97\u70ed\u7ebf <a href=\"tel:02886131795\">028-86131795<\/a> \/ <a href=\"tel:02865272586\">028-65272586<\/a> \u514d\u8d39\u52d8\u6d4b\u62a5\u4ef7\u3002<\/div>\n\n<h2>\u76f8\u5173\u58c1\u6302\u7089\u4e13\u9898\uff08\u5185\u94fe\u5bfc\u822a\uff09<\/h2>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=11082\">\u58c1\u6302\u7089\u591a\u5c11\u94b1<span>\u5168\u54c1\u724c\u4ef7\u683c + \u9f99\u8109\u4f18\u60e0\u4ef7<\/span><\/a>\n  <a href=\"?page_id=11074\">\u58c1\u6302\u7089\u600e\u4e48\u9009<span>\u51b7\u51dd\/\u5e38\u89c4\u00b7\u529f\u7387\u00b7\u54c1\u724c\u6a2a\u8bc4<\/span><\/a>\n  <a href=\"?page_id=835\">\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5<span>\u5fb7\u7cfb\u591a\u7ebf\u9009\u578b<\/span><\/a>\n  <a href=\"?page_id=1841\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5<span>\u5c0f\u6237\u578b\u5730\u6696\u4e13\u7528<\/span><\/a>\n  <a href=\"?page_id=2489\">\u6797\u5185\u58c1\u6302\u7089\u8be6\u60c5<span>\u65e5\u7cfb\u6052\u6e29\u70ed\u6c34<\/span><\/a>\n  <a href=\"?page_id=10970\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4ef7\u683c<span>\u7efc\u5408\u53c2\u8003\u4ef7<\/span><\/a>\n  <a href=\"?page_id=10975\">\u4e24\u8054\u4f9b\u53c2\u8003\u4ef7\u683c<span>\u805a\u5408\u9875<\/span><\/a>\n  <a href=\"?page_id=10977\">\u5730\u6696\u53c2\u8003\u4ef7\u683c<span>\u5730\u6696\u65b9\u6848<\/span><\/a>\n  <a href=\"?page_id=10982\">\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c<span>\u660e\u88c5\u5957\u9910<\/span><\/a>\n<p>\u58c1\u6302\u7089\u5728\u70ed\u6c34\u7cfb\u7edf\u91cc\u7684\u89d2\u8272\uff08\u4e24\u7528\u7089\u4e0e\u7cfb\u7edf\u7089+\u6c34\u7bb1\u600e\u4e48\u9009\u3001\u71c3\u6c14\u8868\u6821\u6838\uff09\uff0c\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=1879\">\u5bb6\u7528\u70ed\u6c34\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7<\/a>\u3002<\/p>\n\n<\/div>\n\n<div class=\"lm-sup-case\">\n\ud83d\udcce <strong>\u6848\u4f8b\u5206\u4eab\uff1a<\/strong>\u770b\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u771f\u5b9e\u8282\u80fd\u8868\u73b0\uff0c\u53ef\u53c2\u8003 <a href=\"?page_id=1841\">\u66fc\u745e\u5fb7 3 \u4e2a\u6210\u90fd\u771f\u5b9e\u6237\u578b\u6848\u4f8b<\/a>\uff08\u540c\u5c5e\u9f99\u8109\u843d\u5730\u6570\u636e\uff09\uff0c\u6216\u5230 <a href=\"?page_id=11082\">\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b<\/a> \u770b\u771f\u5b9e\u6210\u4ea4\u53c2\u8003\uff1b\u60a8\u7684\u4e13\u5c5e\u65b9\u6848\u8bf7\u81f4\u7535\u95e8\u5e97\u9884\u7ea6\u52d8\u6d4b\u3002\n<\/div>\n\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n<details><summary>A1JE \u5e38\u89c4\u7089\u548c B1JG \u51b7\u51dd\u7089\u600e\u4e48\u9009\uff1f<\/summary><p>\u9884\u7b97\u6709\u9650\u3001\u914d\u4f20\u7edf\u6696\u6c14\u7247\u9009 A1JE\uff08\u4e8c\u7ea7\u80fd\u6548\uff0c\u00a58,311 \u8d77\uff09\uff1b\u8ffd\u6c42\u957f\u671f\u7701\u6c14\u3001\u914d\u5730\u6696\u9009 B1JG \u51b7\u51dd\u7089\uff08\u4e00\u7ea7\u80fd\u6548\u3001\u6700\u5c0f\u529f\u7387 3.1kW\u30011:11 \u8c03\u8282\u6bd4\uff0c\u00a513,597 \u8d77\uff09\u3002\u8be6\u89c1\u6b63\u6587\u7b2c\u4e09\u7ae0\u3002<\/p><\/details>\n<details><summary>\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u771f\u7684\u7701\u6c14\u5417\uff1f<\/summary><p>\u53ea\u6709\u4f4e\u6e29\u8fd0\u884c\uff08\u56de\u6c34\uff1c55\u2103\uff09\u624d\u89e6\u53d1\u51b7\u51dd\u3002\u914d\u5730\u6696\/\u4f4e\u6e29\u6696\u6c14\u7247\u5e74\u7701\u6c14\u7ea6 25%\u201335%\uff0c4\u20135 \u5e74\u56de\u672c\uff1b\u914d\u4f20\u7edf\u6696\u6c14\u7247\u51b7\u51dd\u4e0d\u53d1\u751f\uff0c\u7b49\u4e8e\u4e70\u8d35\u4e86\u3002\u8be6\u89c1\u6b63\u6587\u7b2c\u56db\u7ae0\u3002<\/p><\/details>\n<details><summary>\u8fdb\u53e3 B1KF \u548c\u56fd\u4ea7 B1JG \u600e\u4e48\u9009\uff1f<\/summary><p>\u6838\u5fc3\u90e8\u4ef6\u76f8\u8fd1\uff08\u5747 Inox \u4e0d\u9508\u94a2\u6362\u70ed\u5668\u3001\u5168\u9884\u6df7\u71c3\u70e7\uff09\uff0c\u8fdb\u53e3\u7248\u8d35 2,000\u20135,000 \u5143\u3001\u54c1\u63a7\u66f4\u4e25\u3001\u65cb\u94ae\u64cd\u4f5c\uff1b\u7edd\u5927\u591a\u6570\u5bb6\u5ead\u9009 B1JG \u8db3\u591f\u3002\u8be6\u89c1\u6b63\u6587 3.4\u3002<\/p><\/details>\n\n<h2>\u95e8\u5e97\u54a8\u8be2 \u00b7 \u9500\u552e\u7535\u8bdd<\/h2>\n<div class=\"lm-sup-store\">\n  <div class=\"st\">\n    <h4>\u5357\u5bcc\u68ee \u00b7 \u9ad8\u65b0\u5e97<\/h4>\n    <p>\ud83d\udccd \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/p>\n    <p class=\"nav\">\ud83d\uddfa <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892|30.598786|104.074284|30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97 \u203a<\/a><\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u8303\u7ecf\u7406\uff1a<a href=\"tel:13398198375\">133-9819-8375<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u90ed\u7ecf\u7406\uff1a<a href=\"tel:18100839248\">181-0083-9248<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"hotline\"><a href=\"tel:02886131795\">028-86131795<\/a><\/p>\n    <p style=\"font-size:12px;color:#94a3b8;\">\u5357\u5bcc\u68ee\u70ed\u7ebf \u00b7 \u5168\u5929\u5019\u670d\u52a1<\/p>\n  <\/div>\n  <div class=\"st\">\n    <h4>\u5317\u5bcc\u68ee \u00b7 \u6210\u534e\u5e97<\/h4>\n    <p>\ud83d\udccd \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/p>\n    <p class=\"nav\">\ud83d\uddfa <a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547|30.599807|104.07041|30.604665&amp;query_type=IDQ&amp;query=%E6%88%90%E9%83%BD%E6%97%A5%E7%AB%8B%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%99%BA%E6%85%A7%E7%A9%BA%E6%B0%94%E9%A6%86(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8C%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17.5\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97 \u203a<\/a><\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u9ec4\u7ecf\u7406\uff1a<a href=\"tel:15828489188\">158-2848-9188<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u4f59\u7ecf\u7406\uff1a<a href=\"tel:13908183204\">139-0818-3204<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"hotline\"><a href=\"tel:02865272586\">028-65272586<\/a><\/p>\n    <p style=\"font-size:12px;color:#94a3b8;\">\u5317\u5bcc\u68ee\u70ed\u7ebf \u00b7 \u5168\u5929\u5019\u670d\u52a1<\/p>\n  <\/div>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">\u5e95\u90e8\uff1aCTA + \u670d\u52a1\u627f\u8bfa<\/h2>\n\n<p class=\"wp-block-paragraph\">\ud83c\udfaf&nbsp;<strong>\u73b0\u5728\u5c31\u884c\u52a8\uff0c\u62e5\u6709\u5c5e\u4e8e\u60a8\u7684\u5fb7\u7cfb\u5065\u5eb7\u91c7\u6696\uff01<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u627f\u8bfa<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u514d\u8d39\u54a8\u8be2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8054\u7cfb\u6211\u4eec\uff0c\u5373\u53ef\u83b7\u5f971\u5bf91\u65b9\u6848\u8bbe\u8ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e13\u4e1a\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u8c28\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u9009\u578b\uff0c\u63d0\u4f9b1-2\u5957\u4f9b\u6696\u65b9\u6848<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cbe\u5de5\u5b89\u88c5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u683c\u6267\u884c\u7cbe\u5de5\u516d\u6b65\u6cd5\uff0c\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u80fd\u6e90\u4fdd\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u5165\u4f1a\u5458\u8ba1\u5212\uff0c\u9501\u5b9a\u672a\u676510\u5e74\u91c7\u6696\u80fd\u8017\uff0c\u8d85\u51fa\u90e8\u5206\u6211\u4eec\u627f\u62c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u670d\u52a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u7ef4\u62a4\u3001\u6bcf\u5e74\u4e00\u6b21\u514d\u8d39\u4f53\u68c0\u3001\u6545\u969c\u62a5\u4fee30\u5206\u949f\u54cd\u5e94\u30012\u5c0f\u65f6\u5185\u4e0a\u95e8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde&nbsp;<strong>\u6210\u90fd\u5357\u5bcc\u68ee\u70ed\u7ebf\uff1a<a href=\"tel:028-86131795\">028-86131795<\/a><\/strong><br>\ud83d\udcde&nbsp;<strong>\u6210\u90fd\u5317\u5bcc\u68ee\u70ed\u7ebf\uff1a<a href=\"tel:028-86131795\">028-65272586<\/a><\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff1a <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892%7C30.598786%7C104.074284%7C30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\"><\/a><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892%7C30.598786%7C104.074284%7C30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\">\ud83d\udccd \u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/a><br>\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u6210\u534e\u5e97\uff1a<a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547%7C30.599807%7C104.07041%7C30.604665&amp;query_type=IDQ&amp;query=%E6%88%90%E9%83%BD%E6%97%A5%E7%AB%8B%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%99%BA%E6%85%A7%E7%A9%BA%E6%B0%94%E9%A6%86(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8C%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17.5\">\ud83d\udccd \u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/a><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"HomeAndConstructionBusiness\",\n  \"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"description\":\"\u6210\u90fd\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u670d\u52a1\u5546\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u4e24\u8054\u4f9b\u3001\u58c1\u6302\u7089\u4e0a\u95e8\u52d8\u6d4b\u8bbe\u8ba1\u5b89\u88c5\",\n  \"telephone\":\"028\u201186131795\",\n  \"address\":{\"@type\":\"PostalAddress\",\"addressRegion\":\"\u56db\u5ddd\u7701\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u5bcc\u68ee\u7f8e3\u697cA348\"},\n  \"areaServed\":[\"\u9ad8\u65b0\u533a\",\"\u5929\u5e9c\u65b0\u533a\",\"\u6210\u534e\u533a\",\"\u9f99\u6cc9\u9a7f\",\"\u65b0\u90fd\u533a\",\"\u9752\u7f8a\u533a\",\"\u53cc\u6d41\u533a\",\"\u90eb\u90fd\u533a\"],\n  \"openingHours\":\"09:00\u201120:00 \u6696\u901a\u4e0a\u95e8\u52d8\u6d4b\",\n  \"sameAs\":\"https:\/\/longmai\u2011nt.com\",\n  \"hasMap\":[\n    \"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&city=510107&geoobj=104.05892|30.598786|104.074284|30.605656&query_type=IDQ&query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)&zoom=17\",\n    \"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&city=510108&geoobj=104.059547|30.599807|104.07041|30.604665&query_type=IDQ&query=\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986(\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97)&zoom=17.5\"\n  ]\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u8d35\u51e0\u5343\uff0c\u503c\u4e0d\u503c\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u503c\u3002\u5e38\u89c4\u7089\u5bff\u547d8\u201110\u5e74\uff0c\u51b7\u51dd\u708915\u201120\u5e74\u3002\u51b7\u51dd\u7089\u4e00\u5e74\u7701\u6c14\u8d39\u7ea6800\u20111,300\u5143\u3002\u957f\u671f\u4f7f\u75284\u20115\u5e74\u7701\u56de\u5dee\u4ef7\u3002\u800c\u4e14\u51b7\u51dd\u7089\u66f4\u7a33\u5b9a\u3001\u66f4\u9759\u97f3\u3001\u66f4\u73af\u4fdd\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u51b7\u51dd\u7089\u4e3a\u4ec0\u4e48\u4e0d\u7701\u6c14\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u53ea\u6709\u4f4e\u6e29\u8fd0\u884c\u624d\u7701\u6c14\u3002\u56de\u6c34\u6e29\u5ea6\u5fc5\u987b\u4f4e\u4e8e55\u2103\u624d\u80fd\u89e6\u53d1\u51b7\u51dd\u6548\u679c\u3002\u5982\u679c\u8fde\u63a5\u8001\u5f0f\u6696\u6c14\u7247\uff08\u4f9b\u6c3470\u201180\u2103\uff09\uff0c\u51b7\u51dd\u5b8c\u5168\u4e0d\u53d1\u751f\uff0c\u6548\u7387\u751a\u81f3\u4e0d\u5982\u666e\u901a\u7089\u3002\u5fc5\u987b\u914d\u5408\u5730\u6696\u6216\u4f4e\u6e29\u6696\u6c14\u7247\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u83f2\u65af\u66fc\u548c\u5a01\u80fd\u54ea\u4e2a\u597d\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e24\u8005\u90fd\u662f\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\uff0c\u54c1\u8d28\u4e0d\u5206\u4f2f\u4ef2\u3002\u5a01\u80fd\u5728\u54c1\u724c\u8ba4\u77e5\u548c\u552e\u540e\u7f51\u70b9\u4e0a\u66f4\u5e7f\uff0c\u83f2\u65af\u66fc\u5728\u51b7\u51dd\u6280\u672f\u79ef\u7d2f\uff08\u5168\u7cfb\u4e0d\u9508\u94a2Inox\u6362\u70ed\u5668\uff09\u548c\u7ecf\u6d4e\u6027\uff08\u540c\u914d\u7f6e\u7565\u4f4e\uff09\u4e0a\u6709\u4f18\u52bf\u3002\u9009\u9002\u5408\u4f60\u5bb6\u7684\uff0c\u4e0d\u76f2\u4ece\u54c1\u724c\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u4e24\u7528\u7089\u51ac\u5929\u6d17\u6fa1\u6c34\u5ffd\u51b7\u5ffd\u70ed\u600e\u4e48\u529e\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8fd9\u662f\u4e24\u7528\u7089\u7684\u7269\u7406\u77db\u76fe\u3002\u4f18\u9009\u65b9\u6848\uff1a\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u2014\u2014\u7528\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u505a\u91c7\u6696\uff0c\u53e6\u914d\u70ed\u6c34\u5668\u6216\u70ed\u6c34\u7bb1\u4f9b\u70ed\u6c34\uff0c\u5f7b\u5e95\u89e3\u51b3\u3002\u9884\u7b97\u6709\u9650\uff1a\u9009B1JG\u51b7\u51dd\u4e24\u7528\u7089\uff083.1kW\u6700\u5c0f\u529f\u7387\uff0c\u77db\u76fe\u5df2\u5927\u5e45\u7f13\u89e3\uff09\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u8001\u623f\u80fd\u4e0d\u80fd\u88c5\u6696\u6c14\u7247\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u53ef\u4ee5\u3002\u8001\u623f\u6539\u9020\u6807\u914d\u5c31\u662f\u660e\u88c5\u6696\u6c14\u7247\uff0c1\u20113\u5929\u5b8c\u5de5\u3002\u7ba1\u8def\u9690\u85cf\u5728\u8e22\u811a\u7ebf\u3001\u5899\u89d2\uff0c\u51e0\u4e4e\u4e0d\u5f71\u54cd\u7f8e\u89c2\uff0c\u7b2c\u4e8c\u5929\u5c31\u80fd\u7528\u4e0a\u6696\u6c14\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u83f2\u65af\u66fc\u5e38\u89c4\u7089\uff08A1JE\uff09\u503c\u5f97\u4e70\u5417\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5982\u679c\u5bb6\u91cc\u662f\u4f20\u7edf\u6696\u6c14\u7247\u7cfb\u7edf\u3001\u9884\u7b97\u6709\u9650\uff0cA1JE\u662f\u7ecf\u6d4e\u5b9e\u60e0\u7684\u9009\u62e9\u3002\u4f46\u9700\u8981\u6ce8\u610f\uff1a\u590f\u5929\u70ed\u6c34\u4f53\u9a8c\u4e00\u822c\uff08\u6700\u5c0f\u529f\u73876.7kW\uff09\uff0c\u64cd\u4f5c\u9762\u677f\u786e\u5b9e\u4e0d\u597d\u7528\u3002\u5982\u679c\u9884\u7b97\u80fd\u5230\u00a512,000\u4ee5\u4e0a\uff0c\u5f3a\u70c8\u5efa\u8bae\u4e0aB1JG\u51b7\u51dd\u7089\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u8fdb\u53e3B1KF\u548c\u56fd\u4ea7B1JG\u600e\u4e48\u9009\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6838\u5fc3\u90e8\u4ef6\u5dee\u5f02\u4e0d\u5927\uff08\u90fd\u662fInox\u6362\u70ed\u5668\u3001\u5168\u9884\u6df7\u71c3\u70e7\uff09\u3002\u8fdb\u53e3\u7248\u8d352,000\u20115,000\u5143\uff0c\u54c1\u63a7\u66f4\u4e25\u683c\uff0c\u64cd\u4f5c\u9762\u677f\u662f\u65cb\u94ae\u5f0f\u3002\u56fd\u4ea7\u7248\u6027\u4ef7\u6bd4\u66f4\u9ad8\uff0c\u6838\u5fc3\u4ef6\u4ecd\u4e3a\u8fdb\u53e3\u3002\u7edd\u5927\u591a\u6570\u5bb6\u5ead\u9009B1JG\u5b8c\u5168\u591f\u7528\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u5730\u6696\u548c\u6696\u6c14\u7247\u54ea\u4e2a\u66f4\u7701\u94b1\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u770b\u4f7f\u7528\u65b9\u5f0f\uff1a\u5730\u6696\u9002\u540824\u5c0f\u65f6\u5e38\u5f00\uff08\u957f\u671f\u66f4\u7701\uff09\uff0c\u6696\u6c14\u7247\u9002\u5408\u6309\u9700\u5f00\u5173\uff08\u95f4\u6b47\u4f7f\u7528\u66f4\u7701\uff09\u3002\u4e00\u822c\u5efa\u8bae\uff1a\u5168\u5c4b\u5e38\u5f00\u533a\u57df\u9009\u5730\u6696\uff0c\u9700\u8981\u5feb\u901f\u8865\u70ed\u7684\u623f\u95f4\u52a0\u6696\u6c14\u7247\u3002\"}\n    }\n  ]\n}\n<\/script>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><em>\u672c\u6587\u6570\u636e\u6765\u6e90\uff1a\u83f2\u65af\u66fc\u5b98\u7f51\u3001\u56fd\u5bb6\u6807\u51c6CJJ 12-2013\u3001\u6d88\u8d39\u4fdd\u5e73\u53f0\u6295\u8bc9\u8bb0\u5f55\u3001\u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93\u3002\u6240\u6709\u53c2\u6570\u4ee5\u83f2\u65af\u66fc\u5b98\u65b9\u6700\u65b0\u53d1\u5e03\u4e3a\u51c6\u3002<\/em><\/p>\n<\/blockquote>\n\n<nav style=\"--separator: &quot;\/&quot;\" class=\"wp-block-breadcrumbs\" aria-label=\"\u9762\u5305\u5c51\"><ol><li><a href=\"https:\/\/longmai-nt.com\/\">\u9996\u9875<\/a><\/li><li><span aria-current=\"page\">\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875<\/span><\/li><\/ol><\/nav>","protected":false},"excerpt":{"rendered":"<p>1917\u5e74\uff0c\u5fb7\u56fd\u970d\u592b\uff0c\u7ea6\u7ff0\u00b7\u83f2\u65af\u66fc\u521b\u7acb\u4e86 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1824","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff0c\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u3002\u51b7\u51dd\u7089B1JG 3.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\uff1b\u5e38\u89c4\u7089A1JE\u7ecf\u6d4e\u4e4b\u9009\u3002\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u89e3\u51b3\u5ffd\u51b7\u5ffd\u70ed\u3002\u4f4e\u6e29\u6696\u6c14\u7247+\u51b7\u51dd\u7089\u6700\u4f73\u5339\u914d\uff0c\u5730\u6696\/\u660e\u88c5\u6696\u6c14\u7247\u5168\u573a\u666f\u8986\u76d6\u3002\u542b\u56db\u54c1\u724c\u6a2a\u8bc4\u3001\u771f\u5b9e\u53e3\u7891\u3001\u6545\u969c\u4ee3\u7801\u3001\u5b89\u88c5\u89c4\u8303\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1824\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff0c\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u3002\u51b7\u51dd\u7089B1JG 3.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\uff1b\u5e38\u89c4\u7089A1JE\u7ecf\u6d4e\u4e4b\u9009\u3002\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u89e3\u51b3\u5ffd\u51b7\u5ffd\u70ed\u3002\u4f4e\u6e29\u6696\u6c14\u7247+\u51b7\u51dd\u7089\u6700\u4f73\u5339\u914d\uff0c\u5730\u6696\/\u660e\u88c5\u6696\u6c14\u7247\u5168\u573a\u666f\u8986\u76d6\u3002\u542b\u56db\u54c1\u724c\u6a2a\u8bc4\u3001\u771f\u5b9e\u53e3\u7891\u3001\u6545\u969c\u4ee3\u7801\u3001\u5b89\u88c5\u89c4\u8303\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1824\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-10T07:39:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824\",\"name\":\"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png\",\"datePublished\":\"2026-05-28T12:06:18+00:00\",\"dateModified\":\"2026-10-10T07:39:56+00:00\",\"description\":\"\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff0c\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u3002\u51b7\u51dd\u7089B1JG 3.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\uff1b\u5e38\u89c4\u7089A1JE\u7ecf\u6d4e\u4e4b\u9009\u3002\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u89e3\u51b3\u5ffd\u51b7\u5ffd\u70ed\u3002\u4f4e\u6e29\u6696\u6c14\u7247+\u51b7\u51dd\u7089\u6700\u4f73\u5339\u914d\uff0c\u5730\u6696\\\/\u660e\u88c5\u6696\u6c14\u7247\u5168\u573a\u666f\u8986\u76d6\u3002\u542b\u56db\u54c1\u724c\u6a2a\u8bc4\u3001\u771f\u5b9e\u53e3\u7891\u3001\u6545\u969c\u4ee3\u7801\u3001\u5b89\u88c5\u89c4\u8303\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1824#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875 - \u9f99\u8109\u6696\u901a","description":"\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff0c\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u3002\u51b7\u51dd\u7089B1JG 3.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\uff1b\u5e38\u89c4\u7089A1JE\u7ecf\u6d4e\u4e4b\u9009\u3002\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u89e3\u51b3\u5ffd\u51b7\u5ffd\u70ed\u3002\u4f4e\u6e29\u6696\u6c14\u7247+\u51b7\u51dd\u7089\u6700\u4f73\u5339\u914d\uff0c\u5730\u6696\/\u660e\u88c5\u6696\u6c14\u7247\u5168\u573a\u666f\u8986\u76d6\u3002\u542b\u56db\u54c1\u724c\u6a2a\u8bc4\u3001\u771f\u5b9e\u53e3\u7891\u3001\u6545\u969c\u4ee3\u7801\u3001\u5b89\u88c5\u89c4\u8303\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1824","og_locale":"zh_CN","og_type":"article","og_title":"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875 - \u9f99\u8109\u6696\u901a","og_description":"\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff0c\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u3002\u51b7\u51dd\u7089B1JG 3.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\uff1b\u5e38\u89c4\u7089A1JE\u7ecf\u6d4e\u4e4b\u9009\u3002\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u89e3\u51b3\u5ffd\u51b7\u5ffd\u70ed\u3002\u4f4e\u6e29\u6696\u6c14\u7247+\u51b7\u51dd\u7089\u6700\u4f73\u5339\u914d\uff0c\u5730\u6696\/\u660e\u88c5\u6696\u6c14\u7247\u5168\u573a\u666f\u8986\u76d6\u3002\u542b\u56db\u54c1\u724c\u6a2a\u8bc4\u3001\u771f\u5b9e\u53e3\u7891\u3001\u6545\u969c\u4ee3\u7801\u3001\u5b89\u88c5\u89c4\u8303\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=1824","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-10T07:39:56+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"11 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1824","url":"https:\/\/longmai-nt.com\/?page_id=1824","name":"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=1824#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=1824#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png","datePublished":"2026-05-28T12:06:18+00:00","dateModified":"2026-10-10T07:39:56+00:00","description":"\u83f2\u65af\u66fc\u58c1\u6302\u7089\uff0c\u5fb7\u7cfb\u767e\u5e74\u54c1\u724c\u3002\u51b7\u51dd\u7089B1JG 3.1kW\u6700\u5c0f\u529f\u7387\u30011:11\u8c03\u8282\u6bd4\u3001\u4e00\u7ea7\u80fd\u6548\uff1b\u5e38\u89c4\u7089A1JE\u7ecf\u6d4e\u4e4b\u9009\u3002\u91c7\u6696\u70ed\u6c34\u5206\u79bb\u65b9\u6848\u89e3\u51b3\u5ffd\u51b7\u5ffd\u70ed\u3002\u4f4e\u6e29\u6696\u6c14\u7247+\u51b7\u51dd\u7089\u6700\u4f73\u5339\u914d\uff0c\u5730\u6696\/\u660e\u88c5\u6696\u6c14\u7247\u5168\u573a\u666f\u8986\u76d6\u3002\u542b\u56db\u54c1\u724c\u6a2a\u8bc4\u3001\u771f\u5b9e\u53e3\u7891\u3001\u6545\u969c\u4ee3\u7801\u3001\u5b89\u88c5\u89c4\u8303\u3002\u9f99\u8109\u6696\u901a\u6210\u90fd\u6388\u6743\u670d\u52a1\u5546\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1824#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1824"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=1824#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E8%8F%B2%E6%96%AF%E6%9B%BCVitodens-111-W-B1LF.png"},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1824#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u83f2\u65af\u66fc\u58c1\u6302\u7089-\u91c7\u6696\u7cfb\u7edf\u8be6\u60c5\u9875"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1824"}],"version-history":[{"count":22,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1824\/revisions"}],"predecessor-version":[{"id":14478,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1824\/revisions\/14478"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}