{"id":1841,"date":"2026-05-29T17:51:23","date_gmt":"2026-05-29T09:51:23","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1841"},"modified":"2026-10-21T14:31:41","modified_gmt":"2026-10-21T06:31:41","slug":"%e6%9b%bc%e7%91%9e%e5%be%b7%e5%a3%81%e6%8c%82%e7%82%89-%c2%b7-%e9%87%87%e6%9a%96%e7%b3%bb%e7%bb%9f%e8%af%a6%e6%83%85%e9%a1%b5","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1841","title":{"rendered":"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">1995 \u5e74\u66fc\u745e\u5fb7\u59cb\u4e8e\u7a7a\u8c03\u53ca\u5b89\u9632\u7cfb\u7edf\u96c6\u6210\u670d\u52a1\u5546\u3002<br>\u4e09\u5341\u5e74\u540e\uff0c\u5b83\u4ece\u4e00\u5bb6\u7a7a\u8c03\u96c6\u6210\u5546\u6210\u957f\u4e3a\"\u51b7\u6696\u98ce\u6c34\u667a\"\u5168\u4ea7\u4e1a\u94fe\u96c6\u56e2\u3002<br>\u4f46\u6211\u4eec\u4e0d\u53ea\u8bb2\u66fc\u745e\u5fb7\u2014\u2014\u6211\u4eec\u66f4\u60f3\u8ba9\u4f60\u660e\u767d\uff1a<br><strong>\u58c1\u6302\u7089\u7684\u8212\u9002\uff0c\u4e0d\u662f\u4e70\u4e00\u53f0\"\u5927\u724c\"\u5c31\u80fd\u5b9e\u73b0\u7684\uff0c\u800c\u662f\"\u70ed\u6e90-\u8f93\u914d-\u672b\u7aef-\u63a7\u5236\"\u56db\u7ef4\u4e00\u4f53\u7684\u7cfb\u7edf\u5de5\u7a0b\u3002<\/strong><br>\u9f99\u8109\u6696\u901a\u4e0e\u66fc\u745e\u5fb7\u5408\u4f5c16\u5e74\uff0c\u4ece\u63a7\u5236\u5668\u5230\u70ed\u6e90\uff0c\u4ece\u4ee3\u7406\u5230\u8054\u5408\u7814\u53d1\uff0c\u75283400W\u6781\u9650\u6d4b\u8bd5\u7684\u4fe1\u4efb\uff0c\u6362\u6765N1PB18-HI.Pro\u8fd9\u6b3e\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u6253\u9020\u7684\u53d8\u9891\u5c0f\u529f\u7387\u91c7\u6696\u7089\u3002<br>\u4e86\u89e3\u66fc\u745e\u5fb7\uff0c\u4e5f\u662f\u5728\u4e86\u89e3\"\u4e00\u53f0\u5339\u914d\u4f60\u5bb6\u7684\u58c1\u6302\u7089\uff0c\u5e94\u8be5\u600e\u4e48\u9009\"\u3002<\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">\u76ee\u5f55<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ae0\u8282<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9\u6982\u8981<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#mrd01\">\u7b2c\u4e00\u7ae0\uff1a\u5982\u679c\u4f60\u4e5f\u9047\u5230\u8fd9\u4e9b\u95ee\u9898<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5178\u578b\u56f0\u6270 \u00b7 3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b \u00b7 \u4e94\u4ee3\u8fdb\u5316 \u00b7 \u66ff\u4ee3\u65b9\u6848\u5bf9\u6bd4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#mrd02\">\u7b2c\u4e8c\u7ae0\uff1a\u6838\u5fc3\u6280\u672f\u89e3\u6790<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u539f\u7406 \u00b7 \u53d8\u9891\u98ce\u673a \u00b7 \u70ed\u6548\u7387\u8d85100%\u4e4b\u8c1c \u00b7 \u54c1\u724c\u6a2a\u5411\u5bf9\u6bd4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#mrd03\">\u7b2c\u4e09\u7ae0\uff1a\u5173\u4e8e\u58c1\u6302\u7089\uff0c\u8fd9\u4e09\u4ef6\u4e8b\u4f60\u53ef\u80fd\u60f3\u591a\u4e86<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u8d35 \/ \u88c5\u6a71\u67dc \/ \u529f\u7387\u8d8a\u5927\u8d8a\u597d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#mrd04\">\u7b2c\u56db\u7ae0\uff1a\u9009\u578b\u6307\u5357<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e09\u6b65\u9009\u578b \u00b7 \u5b8c\u6574\u53c2\u6570\u8868 \u00b7 \u516d\u95ee\u516d\u7b54 \u00b7 \u5b89\u88c5\u89c4\u8303 \u00b7 \u914d\u7f6e\u6e05\u5355<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#mrd05\">\u7b2c\u4e94\u7ae0\uff1a\u548c\u4f60\u5bb6\u5dee\u4e0d\u591a\u7684\uff0c\u5df2\u7ecf\u7528\u4e0a\u4e86<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">3\u4e2a\u6210\u90fd\u771f\u5b9e\u6848\u4f8b \u00b7 \u6280\u672f\u9a8c\u8bc1\u7ed3\u8bba<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"#mrd06\">\u7b2c\u516d\u7ae0\uff1a\u4f7f\u7528\u4e0e\u7ef4\u62a4\u5b8c\u5168\u624b\u518c<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5feb\u901f\u4e0a\u624b \u00b7 \u56db\u5b63\u6307\u5357 \u00b7 \u6545\u969c\u901f\u67e5 \u00b7 \u4fdd\u517b\u65e5\u5386 \u00b7 \u78c1\u6027\u8fc7\u6ee4\u5668\u6307\u5357<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"mrd01\" class=\"wp-block-heading\">\u7b2c\u4e00\u7ae0\uff1a\u5982\u679c\u4f60\u4e5f\u9047\u5230\u8fd9\u4e9b\u95ee\u9898<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u66fc\u745e\u5fb7\u5b98\u65b9\u7528\u6237\u624b\u518c + \u5b89\u88c5\u8bf4\u660e + \u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93 + \u5ba2\u6237\u6c9f\u901a\u6846\u67b6 + \u5c0f\u7ea2\u4e66\u8bc4\u8bba\u7b54\u7591 + \u9f99\u8109\u6696\u901a\u00b7\u6696\u901a\u7528\u6237\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">1.1 \u5178\u578b\u56f0\u6270<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e38\u89c1\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u771f\u5b9e\u5ba2\u6237\u53cd\u9988<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u95ee\u9898\u6839\u6e90<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u601d\u8def<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u58c1\u6302\u7089\u9891\u7e41\u542f\u505c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u5730\u6696\u4e00\u9635\u70ed\u4e00\u9635\u51c9\uff0c\u7269\u4e1a\u8bf4\u6b63\u5e38\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f20\u7edf24kW\u7089\u6700\u5c0f\u8f93\u51fa8-10kW\uff0c\u8fdc\u8d85\u5c0f\u6237\u578b\u5730\u66963-5kW\u6052\u6e29\u8d1f\u8377<\/td><td class=\"has-text-align-left\" data-align=\"left\">N1PB18-HI.Pro\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u7cbe\u786e\u5339\u914d\u5c0f\u6237\u578b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u6d17\u6fa1\u6d17\u5230\u4e00\u534a\u5c31\u51c9\u4e86\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e24\u7528\u7089\u6700\u5c0f\u529f\u7387\u8fc7\u9ad8\uff0c\u590f\u5b63\u8d85\u6e29\uff1b\u751f\u6d3b\u70ed\u6c34\u4e0e\u91c7\u6696\u5171\u4eab\u70ed\u6e90<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u5bbd\u5e45\u53d8\u9891\uff08\u6700\u5c0f\u7ea63kW\uff09+ \u677f\u6362\u4e24\u7528\u7089\u667a\u80fd\u5207\u6362<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5929\u7136\u6c14\u8d39\u8d85\u6807<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"80\u5e73\uff0c\u4e00\u6708\u71c3\u6c14\u8d39\u6bd4\u90bb\u5c45\u8d35\u4e00\u622a\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089\u4f4e\u6e29\u8fd0\u884c\u6548\u7387\u4f4e\uff0c\u5927\u9a6c\u62c9\u5c0f\u8f66<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\uff0c\u6bd4\u666e\u901a\u7089\u7701\u6c1430%-40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089\u566a\u97f3\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u4e00\u542f\u52a8\u58f0\u97f3\u50cf\u62d6\u62c9\u673a\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u673a\/\u6c34\u6cf5\u5168\u901f\u8fd0\u884c\uff0c\u65e0\u53d8\u9891\u8c03\u901f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c4f\u853d\u9759\u97f3\u6c34\u6cf5+\u76f4\u6d41\u53d8\u9891\u98ce\u673a\uff0c\u4f4e\u566a\u53ef\u8fd1\u5367\u5ba4\u5b89\u88c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u88c5\u4fee\u5e08\u5085\u8bf4\u88c5\u6a71\u67dc\u91cc<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u5e08\u5085\u8bf4\u88c5\u6a71\u67dc\u91cc\u7701\u7a7a\u95f4\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u901a\u98ce\u4e0d\u8db3\u964d\u4f4e\u71c3\u70e7\u6548\u7387\uff0c\u8f7b\u5219\u9891\u7e41\u62a5\u8b66\uff0c\u91cd\u5219\u4e00\u6c27\u5316\u78b3\u79ef\u805a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u7981\u5c01\u95ed\u5f0f\u6a71\u67dc\u5b89\u88c5\uff0c\u4e24\u4fa7\u8ddd\u5899\u2265200mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u5668\u51e0\u5e74\u5c31\u70e7\u4e00\u6b21<\/td><td class=\"has-text-align-left\" data-align=\"left\">\"\u6e29\u63a7\u5668\u8001\u662f\u574f\uff0c\u6362\u4e86\u53c8\u574f\"<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u529f\u7387\u9ad8\u9891\u901a\u65ad\u7535\u6d41\u8ba9\u7ee7\u7535\u5668\u8fc7\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\u7ecf3400W\u6781\u9650\u6d4b\u8bd5\u9a8c\u8bc1\uff0c\u671f\u95f4\u65e0\u96f6\u70e7\u635f\u8bb0\u5f55<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">1.2 \u4ece\"\u70e7\u9762\u677f\"\u5f00\u59cb\u768416\u5e74\u4fe1\u4efb<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u8fc7\u53bb\uff0c\u7535\u91c7\u6696\u63a7\u5236\u7cfb\u7edf\u5982\u4f55\u89e3\u51b3\u7528\u6237\u9700\u6c42\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">2008\u5e74\uff0c\u7535\u91c7\u6696\u884c\u4e1a\u521a\u521a\u8d77\u6b65\uff0c\u6e29\u63a7\u5668\u662f\u6574\u5957\u7cfb\u7edf\u7684\"\u5fc3\u810f\"\u3002\u90a3\u65f6\u5019\u6240\u6709\u54c1\u724c\u90fd\u5728\u505a\u540c\u4e00\u4ef6\u4e8b\uff1a\u628a\u4e00\u4e2a\u7ee7\u7535\u5668\u585e\u8fdb\u76d2\u5b50\u91cc\uff0c\u518d\u8d34\u4e0a\u81ea\u5df1\u7684Logo\u3002\u5bf9\u4e8e2000W\u4ee5\u4e0b\u7684\u8bbe\u5907\uff0c\u8fd9\u5957\u65b9\u6848\u52c9\u5f3a\u591f\u7528\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e3a\u4ec0\u4e48\u90a3\u4e2a\u65b9\u6848\u5f00\u59cb\u4e0d\u591f\u7528\u4e86\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u968f\u7740\u7528\u6237\u5f00\u59cb\u9009\u62e92400W\u4ee5\u4e0a\u53d1\u70ed\u7535\u7f06\u548c2500W\u4ee5\u4e0a\u7535\u52a0\u70ed\u5668\uff0c\u5927\u529f\u7387\u9ad8\u9891\u901a\u65ad\u7535\u6d41\u8ba9\u7ee7\u7535\u5668\u8fc5\u901f\u8fc7\u70ed\u3002\u5f53\u65f6\u9f99\u8109\u6696\u901a\u8bd5\u904d\u4e86\u5e02\u9762\u4e0a\u51e0\u4e4e\u6240\u6709\u4e3b\u6d41\u54c1\u724c\u2014\u2014\u7f8e\u56fd\u9a6c\u5229\u6307\u5b9a\u7684\"\u9ad8\u6807\"\u3001\u67ef\u8010\u5f17\u3001\u6d77\u6797\u2026\u2026\u7ed3\u679c\u5982\u51fa\u4e00\u8f99\uff1a\u5927\u6982\u7387\u70e7\u6bc1\u3002\u9891\u7e41\u7684\u552e\u540e\u4e0d\u4ec5\u541e\u6389\u5229\u6da6\uff0c\u66f4\u4e25\u91cd\u635f\u4f24\u4e86\u5ba2\u6237\u4fe1\u4efb\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u6280\u672f\u7a81\u7834\u53d1\u751f\u5728\u54ea\u91cc\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">2010\u5e74\u524d\u540e\uff0c\u9f99\u8109\u6696\u901a\u627e\u5230\u4e86\u66fc\u745e\u5fb7\uff0c\u5e76\u8fdb\u884c\u4e86\u8fd1\u4e4e\u82db\u523b\u7684\u6d4b\u8bd5\uff1a\u5c06\u66fc\u745e\u5fb7\u7ebf\u63a7\u5668\u63a5\u5230<strong>3400W<\/strong>\u7684\u7535\u91c7\u6696\u8bbe\u5907\u4e0a\u2014\u2014\u6bd4\u5e38\u89c4\u529f\u7387\u9ad8\u51fa\u5c06\u8fd140%\u3002\u6d4b\u8bd5\u7ed3\u679c\u8ba9\u6240\u6709\u4eba\u60ca\u8bb6\uff1a<strong>\u5728\u5176\u4ed6\u54c1\u724c\u5168\u90e8\"\u8d25\u4e0b\u9635\u6765\"\u7684\u6761\u4ef6\u4e0b\uff0c\u66fc\u745e\u5fb7\u4ece\u672a\u51fa\u73b0\u8fc7\u4e00\u6b21\u70e7\u6bc1\u3002<\/strong><\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u6240\u4ee5\u2014\u2014\u4eca\u5929\u4f60\u770b\u5230\u7684\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u89e3\u51b3\u7684\u662f\u90a3\u4e9b\u9760\"\u53e3\u7891\u79ef\u7d2f\"\u7684\u56fd\u4ea7\u54c1\u724c\u89e3\u51b3\u4e0d\u4e86\u7684\u90a3\u4e2a\u95ee\u9898\uff1a\u5728\u771f\u5b9e\u9ad8\u8d1f\u8377\u5de5\u51b5\u4e0b\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">1.3 \u58c1\u6302\u7089\u7684\u4e94\u4ee3\u8fdb\u5316<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u9645<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\u5f62\u6001<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u7684\u6838\u5fc3\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u8868\u7279\u5f81<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c1\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f\u5355\u6bb5\u71c3\u70e7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u70ed\u6c34\u3001\u6709\u91c7\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\u7ea675%\uff0c\u542f\u505c\u7c97\u72b7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c2\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f\u5206\u6bb5\u71c3\u70e7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51cf\u5c11\u80fd\u8017\u6ce2\u52a8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\u7ea682%-85%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c3\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f+\u53d8\u9891\u98ce\u673a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66f4\u5b89\u9759\u3001\u5339\u914d\u5730\u6696\u4f4e\u6e29\u9700\u6c42<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\u7ea687%-93.9%\uff0c\u4ee3\u8868\uff1a\u70ed\u5c9bHI.Pro<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c4\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6df1\u6316\u70df\u6c14\u4f59\u70ed\uff0c\u5927\u5e45\u8282\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\u7a81\u7834100%\uff0c\u4ee3\u8868\uff1a\u5c0f\u5361\u51b7\u51dd\u7089<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c5\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53d8\u9891\u5c0f\u529f\u7387+\u667a\u8054\u63a7\u5236<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u6237\u578b\u5730\u6696\u7cbe\u51c6\u5339\u914d\uff0c\u5168\u5c4b\u7269\u8054<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u8f93\u51fa3-5.6kW\uff0c\u4ee3\u8868\uff1aN1PB18-HI.Pro+\u79bb\u5bb6\u8fd1APP<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\"\u8fd9\u4e0d\u662f\u6280\u672f\u7684\u5806\u780c\uff0c\u662f\u4eba\u7684\u9700\u6c42\u4ece'\u51ac\u5929\u4e0d\u6328\u51bb'\u5230'\u56db\u5b63\u4f4f\u5f97\u8212\u670d'\u7684\u81ea\u7136\u6f14\u8fdb\u3002\"<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">1.4 \u66ff\u4ee3\u65b9\u6848\u5bf9\u6bd4\uff1a\u58c1\u6302\u7089 vs \u7a7a\u6c14\u6e90\u70ed\u6cf5 vs \u7535\u5730\u6696<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7535\u5730\u6696<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u6c14\u6e90\u70ed\u6cf5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u6210\u672c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u8f83\u9ad8\uff08\u5168\u7535\u9a71\u52a8\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u4f4e\uff08COP 3-4\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u8f83\u4f4e\uff08\u51b7\u51dd\u7089\u8282\u6c1430%-40%\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u751f\u6d3b\u70ed\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u65e0\uff08\u9700\u53e6\u914d\u70ed\u6c34\u5668\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f \u90e8\u5206\u673a\u578b\u652f\u6301<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u4e24\u7528\u7089\u81ea\u5e26\u751f\u6d3b\u70ed\u6c34<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u6539\u9020\u96be\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u7b80\u5355<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f \u9700\u5ba4\u5916\u673a\u5b89\u88c5\u7a7a\u95f4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u58c1\u6302\uff0c\u7a7a\u95f4\u5360\u7528\u5c0f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u65e7\u623f\u6539\u9020<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f \u9700\u91cd\u94fa\u5730\u9762<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f \u9700\u589e\u52a0\u7ba1\u9053\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6700\u7075\u6d3b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6781\u5bd2\u5929\u6c14\u6027\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u7a33\u5b9a\uff08\u7535\u70ed\u4e0d\u53d7\u6e29\u5ea6\u5f71\u54cd\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c COP\u4e0b\u964d\uff0c\u6027\u80fd\u5927\u5e45\u8870\u51cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u7a33\u5b9a\uff08\u71c3\u6c14\u71c3\u70e7\u4e0d\u53d7\u5ba4\u5916\u6e29\u5ea6\u5f71\u54cd\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u57ce\u5e02\u71c3\u6c14\u8986\u76d6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f \u987b\u6709\u5929\u7136\u6c14\u7ba1\u9053<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1 \u4e00\u53e5\u8bdd\u603b\u7ed3\uff1a\u7535\u5730\u6696=\u5b89\u88c5\u7b80\u5355\u4f46\u8fd0\u884c\u8d35\uff1b\u7a7a\u6c14\u6e90=\u80fd\u6548\u9ad8\u4f46\u6781\u5bd2\u5931\u6548\uff1b<strong>\u66fc\u745e\u5fb7\u58c1\u6302\u7089=\u91c7\u6696+\u70ed\u6c34\u4e00\u4f53\uff0c\u71c3\u6c14\u57ce\u5e02\u6700\u4f18\u89e3\uff0c\u51b7\u51dd\u6b3e\u957f\u671f\u8d39\u7528\u6700\u4f4e\u3002<\/strong><\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"mrd02\" class=\"wp-block-heading\">\u7b2c\u4e8c\u7ae0\uff1a\u6838\u5fc3\u6280\u672f\u89e3\u6790<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u66fc\u745e\u5fb7\u5b98\u65b9\u6280\u672f\u6587\u6863 + \u80fd\u6548\u68c0\u6d4b\u62a5\u544a + \u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93\u00b7\u91c7\u6696\u6570\u636e\u6c47\u603b<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">2.1 \u4f60\u7684\u56f0\u6270 \u2192 \u6211\u4eec\u7684\u89e3\u6cd5<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f60\u7684\u56f0\u6270<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6211\u4eec\u7684\u89e3\u6cd5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u600e\u4e48\u8bc1\u660e\uff1f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u9891\u7e41\u542f\u505c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53d8\u9891\u5c0f\u529f\u7387\u8bbe\u8ba1\uff08\u6700\u5c0f\u8f93\u51fa5.6kW\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u68c0\u6d4b\u62a5\u544a\uff1a30%\u90e8\u5206\u8d1f\u8377\u70ed\u6548\u738793.9%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5929\u7136\u6c14\u8d39\u7528\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u51b7\u51dd\u6280\u672f\uff0c\u70ed\u6548\u7387108%<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u56fd\u6807GB 20665\u4e00\u7ea7\u80fd\u6548\u8ba4\u8bc1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u566a\u97f3\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c4f\u853d\u9759\u97f3\u6c34\u6cf5+\u76f4\u6d41\u53d8\u9891\u98ce\u673a<\/td><td class=\"has-text-align-left\" data-align=\"left\">IPX4\u9632\u6c34\u7b49\u7ea7\uff0c\u566a\u97f3\u8fbe\u5367\u5ba4\u5468\u8fb9\u5b89\u88c5\u6807\u51c6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u5668\u51e0\u5e74\u5c31\u574f<\/td><td class=\"has-text-align-left\" data-align=\"left\">3400W\u6781\u9650\u6d4b\u8bd5\u9a8c\u8bc1\uff0c\u9f99\u8109\u6696\u901a\u5408\u4f5c\u671f\u95f4\u65e0\u70e7\u635f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9f99\u8109\u6696\u901a\u4e0e\u66fc\u745e\u5fb7\u5408\u4f5c\u8bb0\u5f55\uff0c2010\u5e74\u81f3\u4eca<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u51fa\u6765\u6162<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5373\u70ed\u677f\u6362\u7089\uff0c\u4ea7\u70ed\u6c34\u7387\u6700\u9ad813kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570\u8868\u6838\u9a8c\uff0c\u6807\u79f0\u503c\u7b26\u5408GB 25034\u6807\u51c6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6362\u70ed\u5668\u751f\u6c34\u57a2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u6b3e\u91c7\u7528\u6cd5\u56fd\u8d5b\u8fc8\u8fbeSERMETA 441\u4e0d\u9508\u94a2\u6362\u70ed\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2\u6297\u8150\u8680\uff0c\u516b\u5e74\u6574\u673a\u4fdd\u4fee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">2.2 \u5168\u9884\u6df7\u51b7\u51dd\u6280\u672f\uff08\u5c0f\u5361\u51b7\u51dd\u7089\uff09<\/h3>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5b83\u662f\u4ec0\u4e48<\/strong>\uff1a\u71c3\u70e7\u524d\u5c06\u71c3\u6c14\u4e0e\u7a7a\u6c14\u6309\u7cbe\u786e\u6bd4\u4f8b\u6df7\u5408\uff0c\u5145\u5206\u71c3\u70e7\uff1b\u518d\u901a\u8fc7\u51b7\u51dd\u6362\u70ed\u5668\u56de\u6536\u70df\u6c14\u4f59\u70ed<\/li>\n\n<li><strong>\u5b83\u89e3\u51b3\u4e86\u4ec0\u4e48<\/strong>\uff1a\u666e\u901a\u7089\u70df\u6c14\u6e29\u5ea6\u9ad8\u8fbe150-200\u2103\uff0c\u76f8\u5f53\u4e8e\u76f4\u63a5\u628a\u94b1\u4ece\u70df\u7ba1\u6392\u51fa\u53bb\uff1b\u51b7\u51dd\u7089\u628a\u70df\u6c14\u964d\u523050\u2103\u4ee5\u4e0b\uff0c\u628a\u8fd9\u90e8\u5206\u70ed\u91cf\"\u635e\"\u56de\u6765<\/li>\n\n<li><strong>\u4e3a\u4ec0\u4e48\u80fd\u505a\u5230<\/strong>\uff1a\u6cd5\u56fd\u8d5b\u8fc8\u8fbeSERMETA 441\u4e0d\u9508\u94a2\u6362\u70ed\u5668\u8010\u8150\u8680\u3001\u8010\u4f4e\u6e29\u70df\u6c14\u51b7\u51dd\u6c34\u8150\u8680\uff0c\u914d\u54081:8\u8c03\u8282\u6bd4\u5b9e\u73b0\u8d85\u5bbd\u8d1f\u8377\u8303\u56f4\u8fd0\u884c<\/li>\n\n<li><strong>\u4f60\u611f\u53d7\u5230\u4ec0\u4e48<\/strong>\uff1a\u540c\u7b49\u91c7\u6696\u9762\u79ef\uff0c\u5e74\u71c3\u6c14\u8d39\u7528\u6bd4\u666e\u901a\u7089\u4f4e30%-40%\uff0c140\u33a1\u5317\u65b9\u623f\u5b50\u6bcf\u5e74\u7ea6\u8282\u7701600-1000\u5143<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">2.3 \u76f4\u6d41\u53d8\u9891\u98ce\u673a\uff08N1PB18-HI.Pro \/ \u70ed\u5c9bHI.Pro\uff09<\/h3>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5b83\u662f\u4ec0\u4e48<\/strong>\uff1a\u7528\u7535\u5b50\u8c03\u901f\u76f4\u6d41\u7535\u673a\u9a71\u52a8\u98ce\u673a\uff0c\u800c\u975e\u56fa\u5b9a\u8f6c\u901f\u4ea4\u6d41\u7535\u673a<\/li>\n\n<li><strong>\u5b83\u89e3\u51b3\u4e86\u4ec0\u4e48<\/strong>\uff1a\u5927\u6c14\u5f0f\u666e\u901a\u7089\u98ce\u673a\u5168\u901f\u8fd0\u8f6c\uff0c\u71c3\u70e7\u65f6\u566a\u97f3\u660e\u663e\uff1b\u53d8\u9891\u98ce\u673a\u53ef\u6309\u5b9e\u9645\u8d1f\u8377\u7cbe\u7ec6\u8c03\u901f<\/li>\n\n<li><strong>\u4e3a\u4ec0\u4e48\u80fd\u505a\u5230<\/strong>\uff1a\u914d\u5907\u76f4\u6d41\u98ce\u538b\u5f00\u5173\uff0c\u5b9e\u65f6\u68c0\u6d4b\u71c3\u70e7\u98ce\u538b\uff0c\u786e\u4fdd\u7a7a\u71c3\u6bd4\u7cbe\u51c6\uff0c\u5b89\u5168\u4e0e\u5b89\u9759\u540c\u6b65\u63d0\u5347<\/li>\n\n<li><strong>\u4f60\u611f\u53d7\u5230\u4ec0\u4e48<\/strong>\uff1a\u4f4e\u8d1f\u8377\u8fd0\u884c\u65f6\uff0c\u566a\u97f3\u6bd4\u540c\u7c7b\u4ea7\u54c1\u4e0b\u964d\u7ea65-8dB\uff1b\u9002\u5408\u88c5\u5728\u5367\u5ba4\u6bd7\u90bb\u7684\u9633\u53f0\u6216\u53a8\u623f<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">\ud83d\udd2c \u6df1\u4e00\u5ea6\uff1a\u4e3a\u4ec0\u4e48\u51b7\u51dd\u7089\u70ed\u6548\u7387\u80fd\u8d85\u8fc7100%\uff1f<\/h3>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4e00\u53e5\u8bdd\u6982\u62ec<\/strong>\uff1a\u56e0\u4e3a\u6548\u7387\u7684\u8ba1\u7b97\u57fa\u51c6\u662f\"\u4f4e\u4f4d\u70ed\u503c\"\uff0c\u800c\u51b7\u51dd\u7089\u901a\u8fc7\u56de\u6536\u70df\u6c14\u4e2d\u6c34\u84b8\u6c14\u51b7\u51dd\u6f5c\u70ed\uff0c\u591a\u51fa\u4e86\u4e00\u5757\u80fd\u91cf<\/li>\n\n<li><strong>\u7c7b\u6bd4<\/strong>\uff1a\u5982\u679c\u4e00\u6839\u8721\u70db\u71c3\u70e7\u540e\u7684\u70ed\u91cf\u662f100\u4efd\uff0c\u666e\u901a\u7089\u53ea\"\u6536\"\u4e8685\u4efd\uff0c\u53e615\u4efd\u8ddf\u7740\u70df\u8dd1\u4e86\uff1b\u51b7\u51dd\u7089\u5728\u51fa\u53e3\u88c5\u4e86\u4e2a\"\u70ed\u56de\u6536\u7f51\"\uff0c\u628a\u90a315\u4efd\u751a\u81f3\u66f4\u591a\u90fd\u515c\u4e86\u56de\u6765\uff0c\u6240\u4ee5\u603b\u6536\u5230\u4e86108\u4efd<\/li>\n\n<li><strong>A\uff08\u666e\u901a\u7089\uff09vs B\uff08\u51b7\u51dd\u7089\uff09<\/strong>\uff1a<\/li>\n<\/ol>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u666e\u901a\u7089\uff08\u5927\u6c14\u5f0f\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\uff08\u5168\u9884\u6df7\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6392\u70df\u6e29\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">150-200\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u226450\u2103<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u6c14\u4f59\u70ed\u56de\u6536<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6362\u70ed\u5668\u6750\u8d28<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dc\u5408\u91d1\uff08\u6015\u51b7\u51dd\u6c34\u8150\u8680\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2\uff08\u6297\u9178\u6027\u51b7\u51dd\u6c34\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\uff08\u4f4e\u4f4d\u70ed\u503c\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">82%-93.9%<\/td><td class=\"has-text-align-left\" data-align=\"left\">108%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li><strong>\u7ed3\u8bba<\/strong>\uff1a\u56fd\u6807\u4e00\u7ea7\u80fd\u6548=\u51b7\u51dd\u7089\u4e13\u5c5e\u6807\u51c6\uff0c\u666e\u901a\u7089\u6700\u9ad8\u53ea\u80fd\u8fbe\u5230\u4e8c\u7ea7<\/li>\n<\/ol>\n\n<h3 class=\"wp-block-heading\">2.4 \u54c1\u724c\u6a2a\u5411\u5bf9\u6bd4\uff1a\u66fc\u745e\u5fb7 vs \u540c\u7c7b\u58c1\u6302\u7089\u54c1\u724c<\/h3>\n\n<p class=\"wp-block-paragraph\">\u4e3b\u52a8\u56de\u5e94\u9500\u552e\u4e2d\u6700\u5e38\u9047\u5230\u7684\u95ee\u9898\uff1a<strong>\"\u4f60\u4eec\u66fc\u745e\u5fb7\u548c\u4e07\u5bb6\u4e50\/\u83f2\u65af\u66fc\/\u5a01\u80fd\u6bd4\uff0c\u54ea\u4e2a\u597d\uff1f\"<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u56fd\u4ea7\u666e\u901a\u54c1\u724c\uff08\u4e07\u5bb6\u4e50\/\u4e07\u548c\u7b49\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6b27\u6d32\u8fdb\u53e3\u54c1\u724c\uff08\u5a01\u80fd\/\u83f2\u65af\u66fc\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387\uff08\u51b7\u51dd\u6b3e\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u7ea7\uff08105%-108%\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u7ea7\uff08107%-109%\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u4e00\u7ea7\uff08108%\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u8c03\u8282\u6bd4\uff08\u51b7\u51dd\u7089\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">1:4-1:5<\/td><td class=\"has-text-align-left\" data-align=\"left\">1:7-1:10<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 1:8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6362\u70ed\u5668\u6750\u8d28\uff08\u51b7\u51dd\u6b3e\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2\u6216\u94dd\u5236<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2\uff08\u9ad8\u7aef\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6cd5\u56fd\u8d5b\u8fc8\u8fbe441\u4e0d\u9508\u94a2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6574\u673a\u4fdd\u4fee\uff08\u51b7\u51dd\u6b3e\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">3-5\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">5-8\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 8\u5e74\uff08\u5c0f\u5361\u51b7\u51dd\u7089\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ea\u7814\u6216\u56fd\u4ea7\u6a21\u5757<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ea\u7814\u9ad8\u7aef\u6a21\u5757<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u7f8e\u56fd\u57df\u9002\u90fdResideo\uff08\u51b7\u51dd\u7089\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5faa\u73af\u6c34\u6cf5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u56fd\u4ea7\u54c1\u724c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u683c\u5170\u5bcc\uff08\u90e8\u5206\u578b\u53f7\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u683c\u5170\u5bcc\u53d8\u9891\u6c34\u6cf5\uff08\u51b7\u51dd\u7089\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u667a\u80fdAPP\u63a7\u5236<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u90e8\u5206\u652f\u6301<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u90e8\u5206\u652f\u6301<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u79bb\u5bb6\u8fd1APP\uff08\u8fdc\u7a0b\/AI\u7701\u6c14\/\u96f6\u51b7\u6c34\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e09\u4e2a\u6838\u5fc3\u5dee\u5f02<\/strong>\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4f60\u7701\u591a\u5c11\u94b1<\/strong>\uff1a\u9009\u66fc\u745e\u5fb7\u51b7\u51dd\u7089\uff0c\u6bd4\u8fdb\u53e3\u54c1\u724c\u77013,000-9,000\u5143\uff0c\u540c\u65f6\u4eab\u53d7\u540c\u7b49\u70ed\u6548\u7387\u548c\u4fdd\u4fee\u5e74\u9650<\/li>\n\n<li><strong>\u4f60\u5f97\u5230\u4ec0\u4e48\u4e0d\u540c<\/strong>\uff1a\u8054\u5408\u9f99\u8109\u6696\u901a\u672c\u5730\u5316\u670d\u52a1\uff0c\u5b89\u88c5+\u8c03\u8bd5+\u552e\u540e\u5168\u6d41\u7a0b\u672c\u5730\u54cd\u5e94\uff0c\u4e0d\u7528\u7b49\u5168\u56fd\u7edf\u4e00\u552e\u540e<\/li>\n\n<li><strong>\u4f60\u627f\u62c5\u4ec0\u4e48\u98ce\u9669<\/strong>\uff1a\u76f8\u6bd4\u7eaf\u56fd\u4ea7\u666e\u901a\u7089\uff0c\u591a\u82b1\u7ea65,000\u5143\u4f46\u83b7\u5f971:8\u8c03\u8282\u6bd4\u3001\u4e0d\u9508\u94a2\u6362\u70ed\u5668\u548c8\u5e74\u4fdd\u4fee\uff0c\u957f\u671f\u71c3\u6c14\u8d39\u7528\u66f4\u4f4e<\/li>\n<\/ol>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"mrd03\" class=\"wp-block-heading\">\u7b2c\u4e09\u7ae0\uff1a\u5173\u4e8e\u58c1\u6302\u7089\uff0c\u8fd9\u4e09\u4ef6\u4e8b\u4f60\u53ef\u80fd\u60f3\u591a\u4e86<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u66fc\u745e\u5fb7\u5b98\u65b9\u5b89\u88c5\u8bf4\u660e + \u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93\u00b7\u5ba2\u6237\u6c9f\u901a\u6846\u67b6 + \u5c0f\u7ea2\u4e66\u8bc4\u8bba\u7b54\u7591<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">\u3010\u8bef\u533a\u4e00\u3011\"\u51b7\u51dd\u7089\u8d35\uff0c\u666e\u901a\u7089\u4e5f\u591f\u7528\u4e86\"<\/h3>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4f60\u53ef\u80fd\u542c\u8bf4\u8fc7<\/strong>\uff1a\u51b7\u51dd\u7089\u8981\u8d35\u51e0\u5343\u5757\uff0c\u666e\u901a\u7089\u4e8c\u7ea7\u80fd\u6548\u4e5f\u4e0d\u5dee\uff0c\u6ca1\u5fc5\u8981\u82b1\u8fd9\u4e2a\u94b1<\/li>\n\n<li><strong>\u8bef\u533a\u662f\u600e\u4e48\u5f62\u6210\u7684<\/strong>\uff1a\u5728\u5929\u7136\u6c14\u4ef7\u683c\u8f83\u4f4e\u3001\u91c7\u6696\u9762\u79ef\u8f83\u5c0f\u7684\u65e9\u671f\u5e02\u573a\uff0c\u666e\u901a\u7089\u7684\u80fd\u6548\u5dee\u5f02\u5bf9\u5e74\u8d26\u5355\u5f71\u54cd\u786e\u5b9e\u6709\u9650\uff1b\u52a0\u4e0a\u51b7\u51dd\u7089\u65e9\u671f\u4ef7\u683c\u504f\u9ad8\u3001\u56fd\u5185\u65bd\u5de5\u5bf9\u51b7\u51dd\u6c34\u6392\u653e\u91cd\u89c6\u4e0d\u8db3\uff0c\"\u591a\u82b1\u94b1\u4e70\u6765\u9ebb\u70e6\"\u7684\u5370\u8c61\u6162\u6162\u6d41\u4f20\u5f00\u6765<\/li>\n\n<li><strong>\u771f\u5b9e\u60c5\u51b5\u662f<\/strong>\uff1a\u4ee5140\u33a1\u4f4f\u5b85\u4e3a\u4f8b\uff0c\u5c0f\u5361\u51b7\u51dd\u7089vs\u666e\u901a\u7089\uff0c\u6bcf\u5e74\u71c3\u6c14\u8d39\u7ea6\u5c11\u82b1600-1,000\u5143\uff1b8\u5e74\u4fdd\u4fee\u671f\u5185\uff0c\u8282\u7701\u71c3\u6c14\u8d394,800-8,000\u5143\uff0c\u5b8c\u5168\u8986\u76d6\u521d\u59cb\u6ea2\u4ef7\u3002\u66f4\u91cd\u8981\u7684\u662f\uff1a<strong>\u5c0f\u5361\u51b7\u51dd\u7089\u4fdd\u4fee8\u5e74\uff0c\u666e\u901a\u70892-3\u5e74\uff0c\u4e00\u6b21\u4fee\u7089\u8d39\u7528\u5c31\u662f\u51e0\u767e\u5143\u8d77\u6b65<\/strong><\/li>\n\n<li><strong>\u4f60\u53ef\u4ee5\u9a8c\u8bc1<\/strong>\uff1a\u7528\u4f60\u5bb6\u53bb\u5e74\u7684\u5929\u7136\u6c14\u8d26\u5355\uff0c\u4e58\u4ee50.7\uff08\u6a21\u62df\u8282\u770130%\uff09\uff0c\u7b97\u7b978\u5e74\u80fd\u7701\u591a\u5c11\u94b1<\/li>\n<\/ol>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">\u3010\u8bef\u533a\u4e8c\u3011\"\u58c1\u6302\u7089\u88c5\u6a71\u67dc\u91cc\u66f4\u6574\u6d01\"<\/h3>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4f60\u53ef\u80fd\u542c\u8bf4\u8fc7<\/strong>\uff1a\u58c1\u6302\u7089\u5c31\u662f\u6302\u5899\u4e0a\u7684\u4e1c\u897f\uff0c\u88c5\u5728\u6a71\u67dc\u91cc\u66f4\u7f8e\u89c2\uff0c\u53ea\u8981\u63a5\u4e0a\u7ba1\u5b50\u80fd\u7528\u5c31\u884c<\/li>\n\n<li><strong>\u8bef\u533a\u662f\u600e\u4e48\u5f62\u6210\u7684<\/strong>\uff1a\u65e9\u671f\u58c1\u6302\u7089\u5b89\u88c5\u95e8\u69db\u4f4e\uff0c\u90e8\u5206\u88c5\u4fee\u516c\u53f8\u4e3a\u8282\u7701\u6210\u672c\u6216\u8ffd\u6c42\u7f8e\u89c2\uff0c\u786e\u5b9e\u4f1a\u628a\u58c1\u6302\u7089\u85cf\u8fdb\u6a71\u67dc\u3002\u5f53\u65f6\u71c3\u6c14\u7ba1\u7406\u4e5f\u6ca1\u6709\u73b0\u5728\u4e25\u683c\uff0c\u8fd9\u79cd\u505a\u6cd5\u88ab\u9ed8\u8bb8\u4e86\u5f88\u957f\u65f6\u95f4<\/li>\n\n<li><strong>\u771f\u5b9e\u60c5\u51b5\u662f<\/strong>\uff1a\u58c1\u6302\u7089\u9700\u8981\u6301\u7eed\u8fdb\u6c14\u71c3\u70e7\uff0c\u6a71\u67dc\u5185\u7a7a\u6c14\u91cf\u6709\u9650\uff0c<strong>\u8f7b\u5219\u964d\u4f4e\u71c3\u70e7\u6548\u7387\u3001\u9891\u7e41\u62a5\u8b66\uff0c\u91cd\u5219\u4e00\u6c27\u5316\u78b3\u79ef\u805a\u5f15\u53d1\u5b89\u5168\u4e8b\u6545<\/strong>\u3002\u66fc\u745e\u5fb7\u5b89\u88c5\u89c4\u8303\u660e\u786e\uff1a\u4e24\u4fa7\u8ddd\u5899\u2265200mm\uff0c\u524d\u65b9\u65e0\u906e\u6321\uff0c\u4e25\u7981\u5c01\u95ed\u5f0f\u6a71\u67dc\u5185\u5b89\u88c5\u3002\u6b64\u5916\uff0c\u70df\u7ba1\u5fc5\u987b\u5185\u9ad8\u5916\u4f4e\uff0c\u5426\u5219\u51b7\u51dd\u6c34\u5012\u6d41\u635f\u574f\u7089\u4f53<\/li>\n\n<li><strong>\u4f60\u53ef\u4ee5\u9a8c\u8bc1<\/strong>\uff1a\u628a\u4f60\u7684\u5b89\u88c5\u65b9\u6848\u53d1\u7ed9\u6211\u4eec\uff0c\u514d\u8d39\u5e2e\u4f60\u6838\u67e5\u662f\u5426\u7b26\u5408\u66fc\u745e\u5fb7\u5b98\u65b9\u5b89\u88c5\u89c4\u8303<\/li>\n<\/ol>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">\u3010\u8bef\u533a\u4e09\u3011\"\u5730\u6696\u914d\u4ec0\u4e48\u7089\u90fd\u884c\uff0c\u529f\u7387\u8d8a\u5927\u8d8a\u597d\"<\/h3>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4f60\u53ef\u80fd\u542c\u8bf4\u8fc7<\/strong>\uff1a\u58c1\u6302\u7089\u529f\u7387\u5927\u4e00\u70b9\u4fdd\u9669\uff0c\u5730\u6696\u66f4\u70ed\uff0c\u4e0d\u7528\u62c5\u5fc3\u4e0d\u591f\u7528<\/li>\n\n<li><strong>\u8bef\u533a\u662f\u600e\u4e48\u5f62\u6210\u7684<\/strong>\uff1a\u5728\u6696\u6c14\u7247\u65f6\u4ee3\uff0c\u5927\u529f\u7387\u786e\u5b9e\u610f\u5473\u7740\"\u66f4\u5feb\u70ed\"\uff1b\u5730\u6696\u521a\u5f00\u59cb\u666e\u53ca\u65f6\uff0c\u5927\u5bb6\u4e60\u60ef\u6027\u628a\u6696\u6c14\u7247\u7684\u9009\u8d2d\u903b\u8f91\u5e73\u79fb\u4e86\u8fc7\u6765<\/li>\n\n<li><strong>\u771f\u5b9e\u60c5\u51b5\u662f<\/strong>\uff1a\u5730\u6696\u7cfb\u7edf\u4f9d\u9760\u5927\u9762\u79ef\u8f90\u5c04\u7f13\u6162\u5347\u6e29\uff0c\u5bf9\"\u77ac\u95f4\u5927\u529f\u7387\"\u7684\u9700\u6c42\u8fdc\u4e0d\u5982\u6696\u6c14\u7247\u3002<strong>\u58c1\u6302\u7089\u529f\u7387\u8fc7\u5927\uff0c\u6700\u5c0f\u8f93\u51fa\u503c\u4e5f\u4f1a\u8ddf\u7740\u9ad8\uff0c\u5bfc\u81f4\u5728\u5c0f\u6237\u578b\u4f4e\u8d1f\u8377\u573a\u666f\u4e0b\u9891\u7e41\u542f\u505c\uff0c\u4e0d\u4ec5\u8d39\u6c14\uff0c\u8fd8\u52a0\u901f\u96f6\u90e8\u4ef6\u78e8\u635f\u3002<\/strong> 80-100\u33a1\u5730\u6696\u6807\u914d18kW\uff08\u6700\u5c0f\u8f93\u51fa5.6kW\uff09\u5c31\u591f\uff0c<strong>\u4e0d\u662f\u8d8a\u5927\u8d8a\u597d\uff0c\u800c\u662f\u8d8a\u5339\u914d\u8d8a\u597d<\/strong><\/li>\n\n<li><strong>\u4f60\u53ef\u4ee5\u9a8c\u8bc1<\/strong>\uff1a\u628a\u4f60\u7684\u6237\u578b\u9762\u79ef\u548c\u91c7\u6696\u65b9\u5f0f\u544a\u8bc9\u6211\u4eec\uff0c\u6211\u4eec\u514d\u8d39\u5e2e\u4f60\u505a\u70ed\u8d1f\u8377\u8ba1\u7b97<\/li>\n<\/ol>\n\n<div style=\"margin:18px 0;padding:16px 18px;border-left:4px solid #E8541E;background:#f8fafc;border-radius:0 8px 8px 0;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,'PingFang SC','Microsoft YaHei',sans-serif;\">\n  <h3 style=\"margin:0 0 8px;color:#12314F;font-size:1.15em;\">\u8bef\u533a\u8865\u5145\uff1a\u5c0f\u6237\u578b \/ \u8001\u623f\u660e\u88c5\uff0c\u53cd\u800c\u66f4\u6015\"\u7089\u5b50\u592a\u5927\"<\/h3>\n  <p style=\"margin:0;color:#334155;line-height:1.85;\">\u5f88\u591a\u4e1a\u4e3b\u89c9\u5f97\"\u660e\u88c5\u6696\u6c14\u8981\u9ad8\u6e29\u6c34\uff0c\u5f97\u914d\u5927\u529f\u7387\u7089\"\u3002\u5176\u5b9e\u660e\u88c5\u6696\u6c14\u7247\u7cfb\u7edf\u6c34\u5bb9\u91cf\u5c0f\u3001\u91c7\u6696\u9762\u79ef\u5f80\u5f80\u4e0d\u5927\uff0850\u201390\u33a1\uff09\uff0c\u6700\u6015\u62ff 24kW \u5927\u7089\u5b50\u6765\u914d\u2014\u2014\u529f\u7387\u8d85\u6807\u4f1a\u5bfc\u81f4\u9891\u7e41\u542f\u505c\u3001\u6c34\u6e29\u5ffd\u51b7\u5ffd\u70ed\u3001\u71c3\u6c14\u66f4\u8d39\u3002\u66fc\u745e\u5fb7\u5c0f\u529f\u7387\u53d8\u9891\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u4ec5 5.6kW\uff09\u521a\u597d\u538b\u4f4f\u5c0f\u7cfb\u7edf\u8d1f\u8377\uff0c\u8f93\u51fa\u8ddf\u7740\u623f\u95f4\u9700\u6c42\u8d70\uff0c\u4e0d\u8d85\u6807\u3001\u4e0d\u9891\u7e41\u70b9\u706b\uff0c\u624d\u662f\u5c0f\u6237\u578b \/ \u8001\u623f\u660e\u88c5\u66f4\u7a33\u7684\u9009\u62e9\u3002\u9700\u8981\u9009\u578b\u5efa\u8bae\uff0c\u53ef\u770b\u6211\u4eec\u7684<a href=\"https:\/\/longmai-nt.com\/?page_id=12776\" style=\"color:#E8541E;text-decoration:none;font-weight:600;\">\u660e\u88c5\u6696\u6c14\u00b7\u5c0f\u529f\u7387\u53d8\u9891\u7089\u9009\u578b\u6307\u5357<\/a>\u3002<\/p>\n<\/div>\n\n<h3 class=\"wp-block-heading\">\u3010\u8bef\u533a\u56db\u3011\"\u88c5\u4e86\u6e29\u63a7\u5668\uff0c\u5ba4\u6e29\u5230\u4e86\u58c1\u6302\u7089\u5c31\u505c\u4e86\"<\/h3>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4f60\u53ef\u80fd\u542c\u8bf4\u8fc7<\/strong>\uff1a\u6e29\u63a7\u5668\u4e00\u8bbe\u6e29\u5ea6\uff0c\u623f\u95f4\u6696\u548c\u4e86\u9505\u7089\u5c31\u81ea\u52a8\u505c\u673a\uff0c\u7279\u522b\u7701\u6c14<\/li>\n\n<li><strong>\u8bef\u533a\u662f\u600e\u4e48\u5f62\u6210\u7684<\/strong>\uff1a\u7a7a\u8c03\u5185\u5916\u673a\u662f\u5382\u5bb6\u4e00\u4f53\u5316\u8bbe\u5907\uff0c\u5ba4\u6e29\u5230\u4e86\u4e3b\u673a\u4f1a\u771f\u7684\u505c\u673a\uff0c\u5f88\u591a\u4eba\u628a\u8fd9\u5957\u4e60\u60ef\u5e73\u79fb\u5230\u4e86\u58c1\u6302\u7089+\u5730\u6696\/\u6696\u6c14\u7247\u4e0a<\/li>\n\n<li><strong>\u771f\u5b9e\u60c5\u51b5\u662f<\/strong>\uff1a\u5730\u6696\u3001\u6696\u6c14\u7247\u7684\u6e29\u63a7\u5668\u548c\u58c1\u6302\u7089\u5f80\u5f80\u4e0d\u662f\u540c\u4e00\u54c1\u724c\u3001\u5355\u72ec\u914d\u7f6e\uff0c\u4e8c\u8005\u4e4b\u95f4\u6ca1\u6709\u8054\u52a8\u534f\u8bae\u3002<strong>\u6e29\u63a7\u5668\u5230\u6e29\uff0c\u53ea\u5173\u8fd9\u4e00\u8def\u7684\u6c34\u8def\u9600\u95e8\uff0c\u58c1\u6302\u7089\u81ea\u5df1\u4ecd\u6309\u51fa\u6c34\u6e29\u5ea6\u70e7\u6c34\u3001\u4e0d\u4f1a\u56e0\u6b64\u505c\u673a\u3002<\/strong>\u6240\u6709\u623f\u95f4\u90fd\u5230\u6e29\u4e86\uff0c\u9505\u7089\u7167\u6837\u81ea\u987e\u81ea\u70e7\u2014\u2014\u53cd\u800c\u66f4\u5bb9\u6613\u9891\u7e41\u542f\u505c\u3001\u4ea7\u751f\u65e0\u6548\u70ed\u91cf\u3002\u60f3\u771f\u6b63\"\u5230\u6e29\u5c31\u5c11\u70e7\"\uff0c\u5f97\u9760\u5e26\u8054\u52a8\u7684\u6e29\u63a7\u7cfb\u7edf\uff08\u6e29\u63a7\u5668 + \u4e8c\u901a\u9600 + \u9505\u7089\u901a\u8baf\uff09\uff0c\u8ba9\u9600\u95e8\u5173\u4e86\u4e4b\u540e\u9505\u7089\u4e5f\u8ddf\u7740\u964d\u9891\u6216\u5f85\u673a\u3002\u4e70\u4e4b\u524d\u5148\u786e\u8ba4\u8fd9\u4e09\u8005\u4e4b\u95f4\u6709\u6ca1\u6709\u901a\u8baf\u534f\u8bae\uff0c\u522b\u88ab\"\u88c5\u4e86\u6e29\u63a7\u5668\u5c31\u7701\u6c14\"\u7684\u8bdd\u672f\u5e26\u504f\u3002<\/li>\n\n<li><strong>\u4f60\u53ef\u4ee5\u9a8c\u8bc1<\/strong>\uff1a\u770b\u6e29\u63a7\u5668\u3001\u4e8c\u901a\u9600\u3001\u58c1\u6302\u7089\u662f\u5426\u540c\u4e00\u54c1\u724c\u8054\u52a8\u5957\u4ef6\uff0c\u6216\u660e\u786e\u95ee\u4e00\u53e5\"\u5ba4\u6e29\u5230\u4e86\u9505\u7089\u4f1a\u4e0d\u4f1a\u8ddf\u7740\u5f85\u673a\"<\/li>\n<\/ol>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"mrd04\" class=\"wp-block-heading\">\u7b2c\u56db\u7ae0\uff1a\u9009\u578b\u6307\u5357<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u66fc\u745e\u5fb7\u5b98\u65b9\u53c2\u6570\u624b\u518c + GB 25034-2010 + GB 20665-2015 + JGJ 142-2012 + \u9f99\u8109\u6696\u901a\u00b7\u8bbe\u8ba1\u89c4\u8303V4.1<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">4.1 \u66fc\u745e\u5fb7\u4ea7\u54c1\u7ebf\u5168\u666f<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\u8def\u7ebf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u672b\u7aef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5178\u578b\u529f\u7387<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5c0f\u5361<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u51b7\u51dd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u7ea7\uff08108%\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\/\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">24\/36kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>SKY<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u9884\u6df7\u51b7\u51dd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\/\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">24\/32kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=4499\">\u66fc\u745e\u5fb7\u5355\u91c7\u6696HI.Pro<\/a><\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f+\u5206\u6bb5\u71c3\u70e7+\u53d8\u9891\u98ce\u673a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247\/\u5730\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\">18kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6d77\u5fb7\u5821Heidelberg<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f+\u5206\u6bb5\u71c3\u70e7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">24\/30\/40kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u5c9b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c14\u5f0f+\u5206\u6bb5\u71c3\u70e7+\u53d8\u9891\u98ce\u673a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">18\/20\/24\/26\/30kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>SEA<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5bb9\u79ef\u5f0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">24kW\uff08\u5185\u7f6e60L\u6c34\u7bb1\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/longmai-nt.com\/?page_id=15743\">2026\u5e74\u65b0\u589e\u66fc\u745e\u5fb7\u53d8\u9891\u5206\u6bb5\u71c3\u70e7\u58c1\u6302\u7089\u7b2c\u4e8c\u4ee3\u65b0\u54c1\u6570\u5b57\u7089<\/a><\/p>\n\n<h3 class=\"wp-block-heading\">4.2 \u4e09\u6b65\u627e\u5230\u4f60\u7684\u90a3\u53f0<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e00\u6b65\uff1a\u4f60\u5bb6\u7528\u4ec0\u4e48\u672b\u7aef\uff1f<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u5730\u6696 \u2192 \u4f18\u5148\u51b7\u51dd\u7089\uff08\u4f4e\u6e29\u8fd0\u884c\u6548\u7387\u9ad8\uff09\uff1b\u5c0f\u6237\u578b\u5730\u6696\u9996\u9009<strong>N1PB18-HI.Pro<\/strong><\/li>\n\n<li>\u6696\u6c14\u7247 \u2192 \u666e\u901a\u7089\u6216\u51b7\u51dd\u7089\u5747\u53ef\uff1b\u6309\u9884\u7b97\u9009<\/li>\n\n<li>\u5730\u6696+\u6696\u6c14\u7247\u6df7\u88c5 \u2192 \u9700\u8981\u6df7\u6c34\u4e2d\u5fc3\uff0c\u9009\u6709\u6df7\u6c34\u63a5\u53e3\u7684\u578b\u53f7<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e8c\u6b65\uff1a\u4f60\u5bb6\u9762\u79ef\u591a\u5927\uff1f<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u529f\u7387<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u226480\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">18-20kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">80-120\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">24kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">120-180\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">26-30kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">180-250\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">30-40kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u2265250\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u591a\u7089\u5e76\u8054\u6216\u91c7\u6696\u70ed\u6c34\u5206\u79bb<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e09\u6b65\uff1a\u4f60\u6700\u770b\u91cd\u4ec0\u4e48\uff1f<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f60\u6700\u770b\u91cd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7406\u7531<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u7701\u6c14+8\u5e74\u7701\u5fc3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u5361\u51b7\u51dd\u7089\uff08LL1GQ24-KA\/36-KA\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387108%\uff0c1:8\u8c03\u8282\u6bd4\uff0c\u683c\u5170\u5bcc\u53d8\u9891\u6cf5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u6237\u578b\u5730\u6696\u4e0d\u542f\u505c<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>N1PB18-HI.Pro<\/strong>\uff08\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u7814\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u76f4\u6d41\u53d8\u9891\u98ce\u673a\uff0c\u8d85\u8584250mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247\u00b7\u4e2d\u5927\u6237\u578b\u00b7\u8010\u7528<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d77\u5fb7\u5821Heidelberg Min\u7cfb\u5217<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u6bb5\u71c3\u70e7\uff0c\u529f\u7387\u8303\u56f424-40kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u591a\u536b\u751f\u95f4\u540c\u65f6\u7528\u70ed\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">SEA ST24\uff08\u5bb9\u79ef\u7089\uff0c\u5185\u7f6e60L\u6c34\u7bb1\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5bb9\u79ef\u5f0f\u50a8\u70ed\uff0c\u591a\u4eba\u540c\u65f6\u7528\u4e0d\u51c9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6027\u4ef7\u6bd4\u00b7\u5c0f\u6237\u578b\u4e24\u7528<\/td><td class=\"has-text-align-left\" data-align=\"left\">SUN SH18<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5355\u91c7\u6696+\u751f\u6d3b\u70ed\u6c34\uff0c\u5165\u95e8\u6b3e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">4.3 \u5404\u7cfb\u5217\u5b8c\u6574\u53c2\u6570\u901f\u67e5<\/h3>\n\n<h4 class=\"wp-block-heading\">\u666e\u901a\u7089\u6807\u51c6\u7cfb\u5217<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB20<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB24<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB26<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB30<\/th><th class=\"has-text-align-left\" data-align=\"left\">N1PB40.V<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u70ed\u8f93\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">20kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">24kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">26kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">30kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">40kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u4f9b\u6696\u70ed\u8f93\u51fa<\/td><td class=\"has-text-align-left\" data-align=\"left\">18kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">21.5kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">23.3kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">27kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">36kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u4f9b\u6696\u70ed\u8f93\u51fa<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.2kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">8.5kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">8.7kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">12kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">13.8kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u70ed\u6c34\u7387\uff08\u0394t=25K\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">8.5kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">10kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">11kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">13kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c3a\u5bf8\uff08\u957f\u00d7\u5bbd\u00d7\u9ad8\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">405\u00d7241\u00d7761<\/td><td class=\"has-text-align-left\" data-align=\"left\">405\u00d7241\u00d7761<\/td><td class=\"has-text-align-left\" data-align=\"left\">405\u00d7305\u00d7716<\/td><td class=\"has-text-align-left\" data-align=\"left\">405\u00d7305\u00d7716<\/td><td class=\"has-text-align-left\" data-align=\"left\">510\u00d7330\u00d7750<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\"><a href=\"https:\/\/longmai-nt.com\/?page_id=4499\">\u66fc\u745e\u5fb7\u53d8\u9891\u5355\u91c7\u6696\u7089N1PB18-HI.Pro<\/a>\uff08\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u7814\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u503c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u70ed\u8f93\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">18kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u4f9b\u6696\u70ed\u8f93\u51fa<\/td><td class=\"has-text-align-left\" data-align=\"left\">16.2kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6700\u5c0f\u4f9b\u6696\u70ed\u8f93\u51fa<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>5.6kW<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u6548\u7b49\u7ea7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e8c\u7ea7\uff0830%\u90e8\u5206\u8d1f\u8377\u70ed\u6548\u738793.9%\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c3a\u5bf8\uff08\u957f\u00d7\u5bbd\u00d7\u9ad8\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">410\u00d7250\u00d7660mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u7279\u70b9<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u76f4\u6d41\u53d8\u9891\u98ce\u673a \/ \u5c4f\u853d\u9759\u97f3\u6c34\u6cf5 \/ \u8d85\u8584250mm \/ 4G\u4e91\u7ba1\u5bb6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u5c0f\u5361\u51b7\u51dd\u7089\uff08\u5168\u9884\u6df7\uff0c\u4e00\u7ea7\u80fd\u6548\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">LL1GQ24-KA<\/th><th class=\"has-text-align-left\" data-align=\"left\">LL1GQ36-KA<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u70ed\u8f93\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">24kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">36kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>108%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>108%<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8c03\u8282\u6bd4<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>1:8<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>1:8<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u70ed\u8f93\u51fa<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea63kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6362\u70ed\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6cd5\u56fd\u8d5b\u8fc8\u8fbeSERMETA 441\u4e0d\u9508\u94a2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u5de6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7f8e\u56fd\u57df\u9002\u90fdResideo<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u5de6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5faa\u73af\u6c34\u6cf5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e39\u9ea6\u683c\u5170\u5bcc\u53d8\u9891\u6c34\u6cf5\uff0c\u626c\u7a0b7m<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u5de6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u667a\u80fd\u63a7\u5236<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u79bb\u5bb6\u8fd1APP\uff1a\u8fdc\u7a0b\/AI\u7701\u6c14\/\u6545\u969c\u8bca\u65ad\/\u96f6\u51b7\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u5de6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4fdd\u4fee<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>8\u5e74<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>8\u5e74<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u6d77\u5fb7\u5821Min\u7cfb\u5217<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB24 Min.5<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB30 Min.6<\/th><th class=\"has-text-align-left\" data-align=\"left\">L1PB40 Min.7<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u70ed\u8f93\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">24kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">30kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">40kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u989d\u5b9a\u4f9b\u6696\u70ed\u8f93\u51fa<\/td><td class=\"has-text-align-left\" data-align=\"left\">21.5kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">27kW<\/td><td class=\"has-text-align-left\" data-align=\"left\">36kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u70ed\u6c34\u7387\uff08\u0394t=25K\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">10kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">13kg\/min<\/td><td class=\"has-text-align-left\" data-align=\"left\">18kg\/min<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c3a\u5bf8\uff08\u957f\u00d7\u5bbd\u00d7\u9ad8\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">410\u00d7313\u00d7750<\/td><td class=\"has-text-align-left\" data-align=\"left\">410\u00d7313\u00d7750<\/td><td class=\"has-text-align-left\" data-align=\"left\">510\u00d7330\u00d7750<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<!-- \u5757 A\uff1a\u63d2\u5728\u300c\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u00b7 \u4ea7\u54c1\u56fe\u9274\u300d\u7ae0\u672b\u5c3e\uff0c\u6d77\u5fb7\u5821\u90a3\u6761\u4e4b\u540e -->\n<h3>\u65b0\u4e00\u4ee3\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\u7089\uff08L1PB26 \/ 30 \/ 40\uff09<\/h3>\n<p>\u6d77\u5fb7\u5821\u7cfb\u5217\u7b2c\u4e8c\u4ee3\uff08\u5b98\u65b9\u578b\u53f7 LL1PB26\/30\/40-Heidelberg Min.\uff09\uff0c\u66ff\u4ee3\u4e0a\u4e00\u4ee3 L1PB24\u3002\u4e09\u6863\u529f\u7387\uff0c\u5206\u6bb5\u71c3\u70e7\uff0c\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa\u538b\u5230 7kW \u8d77\uff0c\u5916\u89c2\u6cbf\u7528\u540c\u6b3e\u3002\u5148\u770b\u53c2\u6570\u4e0e\u4ef7\u683c\uff1a<\/p>\n<div style=\"text-align:center;margin:12px 0;\">\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\" alt=\"\u66fc\u745e\u5fb7\u6d77\u5fb7\u5821\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\u58c1\u6302\u7089 L1PB26\/30\/40 \u5916\u89c2\uff08\u4e0e L1PB24 \u540c\u6b3e\uff09\" style=\"max-width:100%;height:auto;max-height:460px;\" loading=\"lazy\">\n<p style=\"font-size:13px;color:#6b7280;margin:8px 0 0 0;\">\u6d77\u5fb7\u5821\u7cfb\u5217\u58c1\u6302\u7089\u5916\u89c2\uff0cL1PB26\/30\/40 \u4e0e\u4e0a\u4e00\u4ee3 L1PB24 \u540c\u6b3e\u3002<\/p>\n<\/div>\n<table style=\"width:100%;border-collapse:collapse;margin:14px 0;font-size:15px;\">\n<tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:9px;text-align:left;\">\u578b\u53f7<\/th><th style=\"border:1px solid #d7dee8;padding:9px;text-align:left;\">\u529f\u7387<\/th><th style=\"border:1px solid #d7dee8;padding:9px;text-align:left;\">\u7c7b\u578b<\/th><th style=\"border:1px solid #d7dee8;padding:9px;text-align:left;\">\u91c7\u6696\u6700\u5c0f\u70ed\u8f93\u51fa<\/th><th style=\"border:1px solid #d7dee8;padding:9px;text-align:left;\">\u8bbe\u5907\u5b98\u65b9\u96f6\u552e\u6307\u5bfc\u4ef7<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:9px;\"><a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">L1PB26<\/a><\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">26kW<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\uff08\u91c7\u6696\uff0b\u70ed\u6c34\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">7kW<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">5,599 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:9px;\"><a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">L1PB30<\/a><\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">30kW<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\uff08\u91c7\u6696\uff0b\u70ed\u6c34\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">9.4kW<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">6,726 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:9px;\"><a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">L1PB40<\/a><\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">40kW<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\uff08\u91c7\u6696\uff0b\u70ed\u6c34\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">12.5kW<\/td><td style=\"border:1px solid #d7dee8;padding:9px;\">7,801 \u5143<\/td><\/tr>\n<\/table>\n<p>\u6d77\u5fb7\u5821 L1PB24-Heidelberg\uff0824kW\uff09\u4e3a\u4e0a\u4e00\u4ee3\u4ea7\u54c1\uff0c\u5df2\u505c\u4ea7\uff0c\u4e0a\u65b9\u56fe\u9274\u4fdd\u7559\u5b83\u7684\u5b9e\u62cd\u56fe\u4e0e\u53c2\u6570\u4ec5\u4f9b\u5df2\u8d2d\u5ba2\u6237\u5bf9\u7167\uff1b\u65b0\u88c5\u8bf7\u6309 L1PB \u4e09\u6863\u9009\u578b\uff0c\u8be6\u7ec6\u53c2\u6570\u4e0e\u9009\u578b\u903b\u8f91\u89c1 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">\u300a\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\u7089\u600e\u4e48\u9009\u300b<\/a>\u3002<\/p>\n\n<!-- \u5757 B\uff1a\u6574\u7ae0\u66ff\u6362\u300c\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u00b7 \u53c2\u8003\u4ef7\u683c\u300d -->\n<h2>\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u00b7 \u53c2\u8003\u4ef7\u683c<\/h2>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;\">\n<tr style=\"background:#f5f7fa;\"><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u578b\u53f7<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u529f\u7387<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u7c7b\u578b<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u5b98\u65b9\u96f6\u552e\u6307\u5bfc\u4ef7<\/th><th style=\"border:1px solid #d7dee8;padding:10px;text-align:left;\">\u9f99\u8109\u53c2\u8003\u4ef7\uff082026\uff09<\/th><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">L1PB26\uff08\u65b0\u6b3e\u4e3b\u63a8\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">26kW<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">5,599 \u5143<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u4e00\u62d6\u4e09\u660e\u88c5\u5957\u9910 9,869 \u5143\uff08\u4f1a\u5458 8,869 \u5143\uff09<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">L1PB30<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">30kW<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">6,726 \u5143<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6309\u914d\u7f6e\u62a5\u4ef7<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">L1PB40<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">40kW<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">7,801 \u5143<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6309\u914d\u7f6e\u62a5\u4ef7<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">L1PB18-HI.Pro\uff08\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u7814\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">18kW<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u53d8\u9891\u5355\u91c7\u6696<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2014<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">4,666 \u5143<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5c0f\u5361\u51b7\u51dd\u7089 LL1GQ24\/36-KA<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">24\/36kW<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5168\u9884\u6df7\u51b7\u51dd\u4e24\u7528<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2014<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">10,900 \u5143\uff08\u533a\u95f4 8,000\u201311,000\uff09<\/td><\/tr>\n<tr><td style=\"border:1px solid #d7dee8;padding:10px;\">\u6d77\u5fb7\u5821 L1PB24-Heidelberg<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">24kW<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\uff08\u65e7\u7cfb\u5217\uff0c\u5df2\u505c\u4ea7\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u2014<\/td><td style=\"border:1px solid #d7dee8;padding:10px;\">\u65e7\u673a\u578b\uff0c\u4ec5\u4f9b\u5df2\u8d2d\u5ba2\u6237\u5bf9\u7167<\/td><\/tr>\n<\/table>\n<p>\u8bf4\u660e\u4e09\u70b9\uff0c\u907f\u514d\u6bd4\u4ef7\u65f6\u8e29\u5751\uff1a<\/p>\n<p>\u2460 <strong>\u8bbe\u5907\u4ef7 \u2260 \u5230\u4f4d\u4ef7\u3002<\/strong> \u4e0a\u8868\u8bbe\u5907\u4ef7\u4e4b\u5916\uff0c\u53e6\u6709\u5b89\u88c5\u8d39 600 \u5143\/\u53f0\uff08\u542b\u6807\u51c6\u5b89\u88c5\u3001\u8c03\u8bd5\uff09\uff0c\u8fd9\u90e8\u5206\u4e0d\u542b\u6696\u6c14\u7247\u548c\u7ba1\u9053\u3002<\/p>\n<p>\u2461 <strong>\u8bbe\u5907\u4ef7 \u2260 \u5957\u9910\u4ef7\u3002<\/strong> \u4e0a\u8868\u300c\u5b98\u65b9\u96f6\u552e\u6307\u5bfc\u4ef7\u300d\u662f\u5355\u53f0\u673a\u5668\u7684\u4ef7\uff0c\u4e0d\u542b\u6696\u6c14\u7247\u3001\u7ba1\u9053\u548c\u5b89\u88c5\uff1b\u660e\u88c5\u6696\u6c14\u5957\u9910\u662f\u300c\u9505\u7089\uff0b\u6696\u6c14\u7247\uff0b\u7ba1\u9053\u8f85\u6750\uff0b\u6807\u51c6\u5b89\u88c5\uff0b\u8c03\u8bd5\u300d\u7684\u5408\u8ba1\u4ef7\uff0c\u4e24\u8005\u4e0d\u80fd\u76f4\u63a5\u6bd4\u3002<\/p>\n<p>\u2462 \u8868\u5185\u300c\u9f99\u8109\u53c2\u8003\u4ef7\u300d\u968f\u914d\u7f6e\u3001\u697c\u5c42\u3001\u7ba1\u7ebf\u8def\u7531\u6d6e\u52a8\uff0c\u6700\u7ec8\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u6e05\u5355\u4e3a\u51c6\u3002\u5b8c\u6574\u5957\u9910\u4ef7\u76ee\u89c1 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=13971\">\u300a\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u5957\u9910\u4ef7\u683c\u300b<\/a>\uff1b\u65b0\u54c1\u4e09\u6863\u53c2\u6570\u4e0e\u9009\u578b\u89c1 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">\u300a\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\u7089\u600e\u4e48\u9009\u300b<\/a>\u3002<\/p>\n<p>\u95e8\u5e97\u70ed\u7ebf 028-86131795 \/ 028-65272586\uff0c\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u62a5\u4ef7\u3002<\/p>\n\n<!-- \u5757 C\uff1a\u5728\u300c\u76f8\u5173\u9605\u8bfb \u00b7 \u9009\u8d2d\u4e0e\u65b9\u6848\u5bfc\u822a\u300d\u91cc\u8ffd\u52a0\u4e00\u6761 -->\n<p>\u00b7 <a href=\"https:\/\/www.longmai-nt.com\/?page_id=15743\">\u66fc\u745e\u5fb7\u5206\u6bb5\u71c3\u70e7\u4e24\u7528\u7089 L1PB26\/30\/40 \u600e\u4e48\u9009<\/a>\u2014\u2014\u4e09\u6863\u529f\u7387\u5bf9\u53f7\u5165\u5ea7\u3001\u5206\u6bb5\u71c3\u70e7\u89e3\u51b3\u4ec0\u4e48\u95ee\u9898\u3001\u8bbe\u5907\u4ef7\u4e0e\u5957\u9910\u4ef7\u600e\u4e48\u5206\u5f00\u770b<\/p>\n\n<h3 class=\"wp-block-heading\">4.4 \u51b7\u51dd\u7089 vs \u666e\u901a\u7089\uff1a\u4e00\u773c\u770b\u6e05\u5dee\u5f02<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u5361\u51b7\u51dd\u7089<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u5c9b\/\u6d77\u5fb7\u5821\u666e\u901a\u7089<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6548\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">108%\uff08\u8d85\u4e00\u7ea7\u80fd\u6548\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">85%-93.9%\uff08\u4e8c\u7ea7\u80fd\u6548\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea63kW\uff081:8\u8c03\u8282\u6bd4\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">5.6-7.2kW<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u672b\u7aef<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\/\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247\u4e3a\u4e3b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u71c3\u6c14\u8d39\uff08\u4f30\u7b97\uff0c140\u33a1\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea6\u77016,000-10,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u57fa\u51c6\u503c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6362\u70ed\u5668\u6750\u8d28<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u9508\u94a2\uff08\u8010\u9178\u6027\u51b7\u51dd\u6c34\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dc\u5408\u91d1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u4fee\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">8\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">2-3\u5e74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u53c2\u8003\u4ef7\u683c<\/td><td class=\"has-text-align-left\" data-align=\"left\">8,000-11,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">4,000-6,000\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">4.5 \u516d\u95ee\u516d\u7b54\uff1a\u9009\u8d2d\u524d\u4f60\u6700\u60f3\u95ee\u7684<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>Q1\uff1a\u5730\u6696\u914d\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u5c0f\u6237\u578b\u5730\u6696\uff08\u2264100\u33a1\uff09\uff0c\u9996\u9009<strong>N1PB18-HI.Pro<\/strong>\uff0818kW\u53d8\u9891\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff09\uff1b\u5927\u6237\u578b\u5730\u6696\uff0c\u9996\u9009\u5c0f\u5361\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u7ea63kW\uff0c\u516b\u5e74\u4fdd\u4fee\uff0c3-5\u5e74\u56de\u672c\uff09\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Q2\uff1a\u6d77\u5fb7\u5821\u548c\u70ed\u5c9b\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u540c\u5c5e\u5927\u6c14\u5f0f\u666e\u901a\u7089\uff08\u4e8c\u7ea7\u80fd\u6548\uff09\uff0c\u4e3b\u8981\u5dee\u5f02\u5728\u578b\u53f7\u8fed\u4ee3\u548c\u5916\u89c2\u5c3a\u5bf8\u3002\u540c\u529f\u7387\u4e0b\u6309\u4ef7\u683c\u548c\u5916\u89c2\u9009\u5373\u53ef\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Q3\uff1aSUN\u7cfb\u5217\u4e09\u4e2a\u578b\u53f7\u600e\u4e48\u9009\uff1f<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>SUN S18\uff08\u5355\u91c7\u6696\uff09\uff1a\u53ea\u9700\u4f9b\u6696\uff0c\u4e0d\u9700\u751f\u6d3b\u70ed\u6c34 \u2192 \u6700\u7701\u94b1<\/li>\n\n<li>SUN SH18\uff08\u4e24\u7528\u7089\uff09\uff1a\u4f9b\u6696+\u6d17\u6fa1 \u2192 \u4e2d\u5c0f\u6237\u578b\u4e3b\u6d41\u9009\u62e9<\/li>\n\n<li>SUN SV18\uff08\u7cfb\u7edf\u7089\uff09\uff1a\u5185\u7f6e\u4e09\u901a\u9600\uff0c\u5916\u63a5\u6c34\u7bb1\u53ef\u540c\u65f6\u4f9b\u591a\u536b\u751f\u95f4\u70ed\u6c34 \u2192 \u5927\u6237\u578b<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>Q4\uff1a\u5b89\u88c5\u4f4d\u7f6e\u53ef\u4ee5\u653e\u6a71\u67dc\u91cc\u5417\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u4e0d\u53ef\u4ee5\u3002\u5fc5\u987b\u5b89\u88c5\u5728\u901a\u98ce\u826f\u597d\u7684\u4f4d\u7f6e\uff08\u53a8\u623f\u3001\u9633\u53f0\uff09\uff0c\u4e24\u4fa7\u9884\u7559\u2265200mm\u3001\u524d\u65b9\u65e0\u906e\u6321\u3001\u5e95\u90e8\u8ddd\u53f0\u9762\u2265300mm\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Q5\uff1a\u70df\u7ba1\u6700\u957f\u80fd\u8d70\u591a\u8fdc\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u540c\u8f74\u70df\u7ba1\u00d860\/100mm\uff0c\u51b7\u51dd\u7089\u6700\u957f8m\uff0c\u666e\u901a\u7089\u7ea64-5m\u3002\u6bcf\u589e\u52a0\u4e00\u4e2a90\u00b0\u5f2f\u5934\u6263\u51cf1m\uff0c45\u00b0\u5f2f\u5934\u6263\u51cf0.5m\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Q6\uff1a\u4e3a\u4ec0\u4e48\u9f99\u8109\u7279\u610f\u63a8N1PB18-HI.Pro\uff1f<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u9f99\u8109\u6696\u901a\u548c\u66fc\u745e\u5fb7\u8054\u5408\u7814\u53d1\u7684\u4ea7\u54c1\uff0c\u4e13\u95e8\u9488\u5bf9\u4f20\u7edf24kW\u58c1\u6302\u7089\u88c5\u5728\u5c0f\u6237\u578b\u5730\u6696\u4e0a\u6700\u5c0f\u8f93\u51fa8-10kW\u8fdc\u8d85\u5730\u6696\u5b9e\u9645\u9700\u6c42\u3001\u5bfc\u81f4\u9891\u7e41\u542f\u505c\u7684\u884c\u4e1a\u75db\u70b9\u800c\u6765\u3002N1PB18\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u5b8c\u7f8e\u5339\u914d\u5c0f\u6237\u578b\u5730\u6696\uff0c\u662f\u8fd9\u4e2a\u7ec6\u5206\u573a\u666f\u91cc\u76ee\u524d\u6700\u4f18\u7684\u89e3\u6cd5\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">4.6 \u5b89\u88c5\u89c4\u8303<\/h3>\n\n<h4 class=\"wp-block-heading\">\u5b89\u88c5\u4f4d\u7f6e\u8981\u6c42<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8981\u6c42<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7089\u4f53\u8ddd\u672a\u88c5\u4fee\u5730\u9762<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.3-1.6m<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7089\u4f53\u4e24\u4fa7\u8ddd\u5899\u9762\/\u6a71\u67dc<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265200mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u9876\u7aef\u8ddd\u5c4b\u9762\/\u540a\u9876<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u226550mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089\u5e95\u90e8\u8ddd\u53f0\u9762<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265300mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u9762\u677f\u524d\u65b9<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u5f97\u6709\u969c\u788d\u7269<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7981\u6b62<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c01\u95ed\u5f0f\u6a71\u67dc\u5185\u5b89\u88c5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u70df\u7ba1\u5b89\u88c5\u89c4\u8303<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u8303<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u578b\u53f7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u540c\u8f74\u00d860\/100mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u503e\u659c\u65b9\u5411<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5185\u9ad8\u5916\u4f4e\uff0c\u503e\u659c1-3\u00b0\uff08\u9632\u6b62\u51b7\u51dd\u6c34\u56de\u6d41\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5899\u5b54\u8ddd\u5730\u9762<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22652.2m<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5899\u5b54\u79bb\u7a97\u6237<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u226540mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u70df\u7ba1\u51fa\u5899\u957f\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fdb\u6c14\u53e3\u51fa\u5899\u2265100mm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5927\u5f53\u91cf\u957f\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u22648m\uff1b\u666e\u901a\u7089\u22644-5m<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">90\u00b0\u5f2f\u5934\u5f53\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">=\u76f4\u7ba11m<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">45\u00b0\u5f2f\u5934\u5f53\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">=\u76f4\u7ba10.5m<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u7cfb\u7edf\u6253\u538b\u9a8c\u6536\u6807\u51c6<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9a8c\u6536\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6253\u538b\u503c<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.6MPa<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7a33\u538b\u65f6\u95f4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22651\u5c0f\u65f6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5141\u8bb8\u538b\u964d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u22640.05MPa<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f9d\u636e<\/td><td class=\"has-text-align-left\" data-align=\"left\">GB 50242-2002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">4.7 \u6807\u51c6\u914d\u7f6e\u6e05\u5355<\/h3>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u4e3a\u9f99\u8109\u6696\u901a\u5e38\u89c4\u5b89\u88c5\u5305\u914d\u7f6e\uff08\u5b9e\u9645\u4ee5\u73b0\u573a\u52d8\u6d4b\u62a5\u4ef7\u4e3a\u51c6\uff09<\/p>\n<\/blockquote>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5e8f\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89c4\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089\u4e3b\u673a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6309\u9009\u578b\u529f\u7387<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u542b\u5305\u88c5\u9644\u4ef6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u540c\u8f74\u70df\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u00d860\/100mm\uff0c1m\u6807\u51c6\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u542b\u7ec8\u7aef\u5934<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6302\u677f\u53ca\u7d27\u56fa\u4ef6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u539f\u5382\u6807\u914d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u4f9b\u56de\u6c34\u4e3b\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">PPR\/DN25<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089\u81f3\u5206\u96c6\u6c34\u5668<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u7ba1\u8def<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9540\u950c\u94a2\u7ba1\/DN15+\u71c3\u6c14\u4e13\u7528\u9600\u95e8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u751f\u6d3b\u51b7\u70ed\u6c34\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">PPR\/DN15-DN20<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u6c34\u7ba1\uff08\u51b7\u51dd\u7089\u4e13\u7528\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">PVC\u8010\u8150\u8680\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5761\u5ea6\u22653\u00b0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u9053\u4fdd\u6e29<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6a61\u5851\u4fdd\u6e29\u7ba1\uff0c\u58c1\u539a\u226520mm<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u4e3b\u7ba1\u5168\u7a0b\u4fdd\u6e29<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">9<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5ba4\u5185\u6e29\u63a7\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7RT1\u6db2\u6676\u6e29\u63a7\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u91c7\u6696\u5206\u533a1\u4e2a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u78c1\u6027\u9664\u6c61\u8fc7\u6ee4\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">DN25<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u5728\u56de\u6c34\u7ba1\u8def<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">11<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u6cc4\u6f0f\u62a5\u8b66\u5668+\u7535\u78c1\u5207\u65ad\u9600<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53a8\u623f\u5b89\u88c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">12<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8865\u6c34\u9600\u7ec4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u542b\u5355\u5411\u9600<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">13<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u96c6\u6c34\u5668\uff08\u5730\u6696\u65b9\u6848\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7Yi\u7cfb\u5217\u9632\u7ed3\u57a2\u667a\u80fd\u53cc\u8c03\u8282\u578b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u56de\u8def\u6570\u6309\u8bbe\u8ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">14<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u7ba1\uff08\u5730\u6696\u65b9\u6848\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7MElle PE-Xa\u4e94\u5c42\u963b\u6c27\u4ea4\u8054\u805a\u4e59\u70ef\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">DN16\/DN20<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"mrd05\" class=\"wp-block-heading\">\u7b2c\u4e94\u7ae0\uff1a\u548c\u4f60\u5bb6\u5dee\u4e0d\u591a\u7684\uff0c\u5df2\u7ecf\u7528\u4e0a\u4e86<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u9f99\u8109\u6696\u901a\u00b7\u5ba2\u6237\u6863\u6848 + \u5de5\u7a0b\u5e08\u5b89\u88c5\u8bb0\u5f55 + \u552e\u540e\u56de\u8bbf<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">\u6848\u4f8b\u4e00 | \u6210\u90fd\u00b7\u91d1\u725b\u533a\u00b7100\u33a1\u5730\u6696\u6539\u9020<\/h3>\n\n<p class=\"wp-block-paragraph\">\ud83d\udccd \u6210\u90fd\u00b7\u91d1\u725b\u533a<br>\ud83c\udfe0 \u4e09\u5ba4\u4e24\u5385\uff0c\u5efa\u7b51\u9762\u79ef100\u33a1\uff0c\u5730\u6696\u7cfb\u7edf<br>\ud83c\udfaf \u6838\u5fc3\u9700\u6c42\uff1a\u8001\u623f\u7535\u91c7\u6696\u6539\u71c3\u6c14\u58c1\u6302\u7089\u5730\u6696\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\u95ee\u9898<br>\u2699\ufe0f \u914d\u7f6e\u65b9\u6848\uff1a<strong>N1PB18-HI.Pro<\/strong>+\u66fc\u745e\u5fb7Yi\u7cfb\u5217\u5206\u96c6\u6c34\u5668+MElle PE-Xa\u5730\u6696\u7ba1+RT1\u6e29\u63a7\u5668<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\"\u4e4b\u524d\u7528\u7684\u4e00\u53f024kW\u7684\u7089\u5b50\uff0c\u5730\u6696\u660e\u663e\u4e00\u9635\u70ed\u4e00\u9635\u51c9\uff0c\u7269\u4e1a\u8bf4\u662f\u6b63\u5e38\u7684\u3002\u88c5\u4e86N1PB18\u4e4b\u540e\uff0c\u5730\u9762\u57fa\u672c\u4e00\u76f4\u662f\u6e29\u70ed\u7684\uff0c\u6ca1\u6709\u518d\u51fa\u73b0\u90a3\u79cd'\u4e00\u811a\u8e29\u4e0a\u53bb\u70eb\u3001\u53e6\u4e00\u811a\u8e29\u4e0a\u53bb\u51c9'\u7684\u611f\u89c9\u3002\"<\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">\ud83d\udd0d \u6280\u672f\u9a8c\u8bc1\u7ed3\u8bba\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u5339\u914d\u5ea6\uff1a100\u33a1\u5730\u6696\u70ed\u8d1f\u8377\u7ea66,000-8,000W\uff0cN1PB18-HI.Pro\u6700\u5c0f\u8f93\u51fa5,600W \u2192 \u4f4e\u8d1f\u8377\u4e0d\u518d\u9891\u7e41\u542f\u505c \u2705<\/li>\n\n<li>\u80fd\u6548\uff1a30%\u90e8\u5206\u8d1f\u8377\u5b9e\u6d4b\u70ed\u6548\u738793.9%\uff0c\u7b26\u5408\u4e8c\u7ea7\u80fd\u6548 \u2705<\/li>\n\n<li>\u6838\u5fc3\u7ed3\u8bba\uff1a\u529f\u7387\u5339\u914d\u662f\u5730\u6696\u8212\u9002\u5ea6\u7684\u9996\u8981\u56e0\u7d20\uff0cN1PB18-HI.Pro\u662f\u8be5\u573a\u666f\u76ee\u524d\u6700\u4f18\u89e3<\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">\u6848\u4f8b\u4e8c | \u6210\u90fd\u00b7\u9ad8\u65b0\u533a\u00b7160\u33a1\u5168\u5c4b\u51b7\u51dd\u7089\u65b9\u6848<\/h3>\n\n<p class=\"wp-block-paragraph\">\ud83d\udccd \u6210\u90fd\u00b7\u9ad8\u65b0\u533a<br>\ud83c\udfe0 \u56db\u5ba4\u4e24\u5385\uff0c\u5efa\u7b51\u9762\u79ef160\u33a1\uff0c\u5730\u6696\u7cfb\u7edf<br>\ud83c\udfaf \u6838\u5fc3\u9700\u6c42\uff1a\u65b0\u623f\u7cbe\u88c5\uff0c\u8ffd\u6c42\u957f\u671f\u8282\u80fd\uff0c\u8981\u6c42\u667a\u80fd\u63a7\u5236<br>\u2699\ufe0f \u914d\u7f6e\u65b9\u6848\uff1a<strong>\u5c0f\u5361\u51b7\u51dd\u7089LL1GQ24-KA<\/strong>+\u66fc\u745e\u5fb7Yi\u7cfb\u5217\u5206\u96c6\u6c34\u5668+\u79bb\u5bb6\u8fd1APP\u667a\u80fd\u63a7\u5236<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\"\u79bb\u5bb6\u8fd1APP\u5f88\u597d\u7528\uff0c\u56de\u5bb6\u524d\u534a\u5c0f\u65f6\u5728\u8def\u4e0a\u6253\u5f00\uff0c\u5230\u5bb6\u5c31\u662f\u6696\u7684\u3002AI\u7701\u6c14\u529f\u80fd\u5f00\u542f\u540e\uff0c\u4e0a\u4e2a\u6708\u5929\u7136\u6c14\u8d26\u5355\u6bd4\u90bb\u5c45\u540c\u9762\u79ef\u7684\u5c11\u4e86\u5c06\u8fd1\u4e24\u767e\u5757\u3002\"<\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">\ud83d\udd0d \u6280\u672f\u9a8c\u8bc1\u7ed3\u8bba\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u70ed\u6548\u7387\uff1a108%\uff08\u4e00\u7ea7\u80fd\u6548\uff09\uff0c\u6bd4\u540c\u6b3e\u666e\u901a\u7089\u8282\u6c14\u7ea625%-35% \u2705<\/li>\n\n<li>\u8c03\u8282\u6bd4\uff1a1:8\uff0c\u6700\u5c0f\u8f93\u51fa\u7ea63kW\uff0c\u9002\u5408\u5730\u6696\u7cbe\u7ec6\u63a7\u6e29 \u2705<\/li>\n\n<li>\u4fdd\u4fee\uff1a8\u5e74\u6574\u673a\u4fdd\u4fee\uff0c\u540c\u7c7b\u666e\u901a\u70892-3\u5e74 \u2705<\/li>\n\n<li>\u6838\u5fc3\u7ed3\u8bba\uff1a160\u33a1\u5730\u6696\u573a\u666f\u4e0b\uff0c\u5c0f\u5361\u51b7\u51dd\u70893-4\u5e74\u71c3\u6c14\u8282\u7701\u53ef\u8986\u76d6\u521d\u59cb\u6ea2\u4ef7<\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">\u6848\u4f8b\u4e09 | \u6210\u90fd\u00b7\u6b66\u4faf\u533a\u00b7\u65e7\u623f\u6696\u6c14\u7247\u7f6e\u6362<\/h3>\n\n<p class=\"wp-block-paragraph\">\ud83d\udccd \u6210\u90fd\u00b7\u6b66\u4faf\u533a<br>\ud83c\udfe0 \u4e24\u5ba4\u4e00\u5385\uff0c\u5efa\u7b51\u9762\u79ef85\u33a1\uff0c\u539f\u6709\u94f8\u94c1\u6696\u6c14\u7247<br>\ud83c\udfaf \u6838\u5fc3\u9700\u6c42\uff1a\u65e7\u9505\u7089\u8001\u5316\u7f6e\u6362\uff0c\u4e0d\u6539\u6696\u6c14\u7247\uff0c\u8981\u6c42\u5b89\u88c5\u7b80\u5355\u5feb\u6377<br>\u2699\ufe0f \u914d\u7f6e\u65b9\u6848\uff1a<strong>\u6d77\u5fb7\u5821Heidelberg Min L1PB24 Min.5<\/strong>+\u78c1\u6027\u9664\u6c61\u8fc7\u6ee4\u5668+RT1\u6e29\u63a7\u5668<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\"\u6211\u4eec\u5bb6\u662f90\u5e74\u4ee3\u7684\u6696\u6c14\u7247\uff0c\u4e00\u76f4\u7528\u7684\u96c6\u4f53\u4f9b\u6696\uff0c\u540e\u6765\u6539\u81ea\u4f9b\uff0c\u88c5\u4fee\u5e08\u5085\u63a8\u8350\u7684\u9f99\u8109\u3002\u4e00\u5929\u88c5\u5b8c\uff0c\u7b2c\u4e8c\u5929\u5c31\u7528\u4e0a\u4e86\uff0c\u6c34\u538b\u7a33\uff0c\u6ca1\u51fa\u73b0\u8fc7\u6f0f\u6c34\u3002\"<\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">\ud83d\udd0d \u6280\u672f\u9a8c\u8bc1\u7ed3\u8bba\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u65bd\u5de5\u4eae\u70b9\uff1a\u78c1\u6027\u9664\u6c61\u8fc7\u6ee4\u5668\u6709\u6548\u4fdd\u62a4\u65e7\u6696\u6c14\u7247\u7ba1\u8def\u4e2d\u7684\u6b8b\u7559\u6742\u8d28\u4e0d\u8fdb\u5165\u7089\u4f53 \u2705<\/li>\n\n<li>\u6253\u538b\u9a8c\u6536\uff1a0.6MPa\u7a33\u538b1\u5c0f\u65f6\uff0c\u538b\u964d0.02MPa\uff0c\u7b26\u5408GB 50242\u6807\u51c6 \u2705<\/li>\n\n<li>\u6838\u5fc3\u7ed3\u8bba\uff1a\u65e7\u623f\u6696\u6c14\u7247\u7f6e\u6362\u9996\u9009\u666e\u901a\u7089\uff0c\u5feb\u901f\u5b89\u88c5\u3001\u7cfb\u7edf\u517c\u5bb9\u597d\uff0c\u65e0\u9700\u5927\u5e45\u6539\u52a8\u7ba1\u8def<\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 id=\"mrd06\" class=\"wp-block-heading\">\u7b2c\u516d\u7ae0\uff1a\u4f7f\u7528\u4e0e\u7ef4\u62a4\u5b8c\u5168\u624b\u518c<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4fe1\u606f\u4f9d\u636e\uff1a\u66fc\u745e\u5fb7\u5b98\u65b9\u7528\u6237\u624b\u518c + \u5b89\u88c5\u8bf4\u660e + \u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93\u00b7\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">6.1 \u5feb\u901f\u4e0a\u624b<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u600e\u4e48\u505a<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9996\u6b21\u70b9\u706b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u786e\u8ba4\u71c3\u6c14\u9600\u5df2\u5f00 \u2192 \u63a5\u901a\u7535\u6e90 \u2192 \u9762\u677f\u81ea\u52a8\u8fdb\u5165\u5f85\u673a\u6a21\u5f0f \u2192 \u6e29\u63a7\u5668\u8bbe\u5b9a\u76ee\u6807\u6e29\u5ea6 \u2192 \u58c1\u6302\u7089\u81ea\u52a8\u70b9\u706b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5207\u6362\u91c7\u6696\/\u70ed\u6c34\u6a21\u5f0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9762\u677f\u4e0a\u65cb\u8f6c\u91c7\u6696\/\u70ed\u6c34\u65cb\u94ae\uff1b\u53cc\u6a21\u5f0f\u7089\u4f18\u5148\u54cd\u5e94\u751f\u6d3b\u70ed\u6c34\u8bf7\u6c42<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8c03\u8282\u91c7\u6696\u6c34\u6e29<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65cb\u94ae\u65cb\u81f340-60\u2103\uff08\u5730\u6696\uff09\uff0c\u621655-75\u2103\uff08\u6696\u6c14\u7247\uff09\uff1b\u6e29\u63a7\u5668\u8054\u52a8\u63a7\u5236\u5ba4\u6e29\u66f4\u7cbe\u51c6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u8865\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u67e5\u770b\u538b\u529b\u8868\uff0c\u4f4e\u4e8e0.8bar\u65f6\u5f00\u8865\u6c34\u9600\uff0c\u8865\u6c34\u81f31.2-1.5bar\u540e\u5173\u95ed<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u590f\u5b63\u505c\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u91c7\u6696\u65cb\u94ae\uff0c\u70ed\u6c34\u529f\u80fd\u4fdd\u6301\u6b63\u5e38\uff1b\u957f\u671f\u4e0d\u7528\u53ef\u5173\u95ed\u4e3b\u71c3\u6c14\u9600<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.2 \u56db\u5b63\u4f7f\u7528\u6307\u5357<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5b63\u8282<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae\u8bbe\u7f6e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6ce8\u610f\u4e8b\u9879<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83c\udf38 \u6625\u5b63\uff083-5\u6708\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u964d\u4f4e\u91c7\u6696\u6c34\u6e29\u81f335-40\u2103\uff0c\u6216\u76f4\u63a5\u5173\u91c7\u6696\u4fdd\u7559\u70ed\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u7cfb\u7edf\u6c34\u538b\uff0c\u8865\u6c34\u81f31.2bar<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u2600\ufe0f \u590f\u5b63\uff086-9\u6708\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u91c7\u6696\uff0c\u70ed\u6c34\u6e29\u5ea6\u8c03\u81f340-45\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u671f\u68c0\u67e5\u70df\u7ba1\u51fa\u53e3\u662f\u5426\u6709\u9e1f\u5de2\u6216\u6742\u7269\u5835\u585e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\ud83c\udf42 \u79cb\u5b63\uff0810-11\u6708\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63d0\u524d1\u5468\u5f00\u542f\u91c7\u6696\uff0c\u68c0\u67e5\u7ba1\u8def\u662f\u5426\u6b63\u5e38<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u81a8\u80c0\u6c34\u7bb1\u3001\u5b89\u5168\u9600\u662f\u5426\u6b63\u5e38\uff1b\u9996\u6b21\u70b9\u706b\u89c2\u5bdf\u662f\u5426\u62a5\u8b66<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u2744\ufe0f \u51ac\u5b63\uff0812-\u6b21\u5e742\u6708\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u63a8\u835040-55\u2103\uff0c\u6696\u6c14\u7247\u63a8\u835060-75\u2103\uff1b\u5ba4\u6e29\u8bbe20-22\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u65f6\u95f4\u4e0d\u5728\u5bb6\u65f6\uff0c\u7ef4\u6301\u9632\u51bb\u6a21\u5f0f\uff08\u8bbe10\u2103\uff09\uff0c\u7981\u6b62\u5b8c\u5168\u5173\u673a\uff1b\u56de\u5bb6\u524d\u8fdc\u7a0b\u901a\u8fc7\u79bb\u5bb6\u8fd1APP\u63d0\u524d\u5f00\u542f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.3 \u5e38\u89c1\u95ee\u9898\u901f\u67e5<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u73b0\u8c61<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5148\u8bd5\u8bd5\u8fd9\u51e0\u6b65<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8fd8\u6ca1\u89e3\u51b3\uff1f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u58c1\u6302\u7089\u4e0d\u542f\u52a8<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2460 \u786e\u8ba4\u7535\u6e90\u6b63\u5e38 \u2461 \u786e\u8ba4\u71c3\u6c14\u9600\u5df2\u5f00 \u2462 \u68c0\u67e5\u6c34\u538b\u662f\u5426\u57281-2bar\u533a\u95f4 \u2463 \u67e5\u770b\u9762\u677f\u662f\u5426\u6709\u6545\u969c\u7801<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8054\u7cfb\u9f99\u8109\u6696\u901a\u552e\u540e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u538b\u4f4e\u62a5\u8b66\uff08\u4f4e\u4e8e0.8bar\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2460 \u627e\u5230\u8865\u6c34\u9600\uff08\u901a\u5e38\u5728\u7089\u4f53\u5e95\u90e8\uff09 \u2461 \u7f13\u6162\u6253\u5f00\u8865\u6c34\u9600 \u2462 \u6c34\u538b\u5347\u81f31.2-1.5bar\u540e\u5173\u95ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u82e5\u8865\u6c34\u540e\u538b\u529b\u5feb\u901f\u4e0b\u964d\uff0c\u8bf4\u660e\u7cfb\u7edf\u6709\u6f0f\u6c34\uff0c\u8054\u7cfb\u552e\u540e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5730\u6696\u5ffd\u51b7\u5ffd\u70ed<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2460 \u68c0\u67e5\u5206\u96c6\u6c34\u5668\u5404\u56de\u8def\u662f\u5426\u5168\u90e8\u5f00\u542f \u2461 \u786e\u8ba4\u5faa\u73af\u6c34\u6cf5\u8fd0\u884c\u6b63\u5e38\uff08\u542c\u6cf5\u58f0\uff09 \u2462 \u9002\u5f53\u63d0\u9ad8\u91c7\u6696\u6c34\u6e295\u2103<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ef\u80fd\u662f\u5206\u96c6\u6c34\u5668\u67d0\u56de\u8def\u5835\u585e\uff0c\u8054\u7cfb\u552e\u540e\u51b2\u6d17<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6253\u5f00\u70ed\u6c34\u9f99\u5934\u6ca1\u70ed\u6c34<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2460 \u786e\u8ba4\u7089\u4f53\u5904\u4e8e\u70ed\u6c34\u6a21\u5f0f \u2461 \u68c0\u67e5\u51b7\u6c34\u8fdb\u6c34\u538b\u529b\uff08\u9700\u22650.05MPa\uff09 \u2462 \u7b49\u5f8510-30\u79d2\uff0c\u51b7\u6c34\u6392\u5c3d\u540e\u70ed\u6c34\u51fa\u6765<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u96f6\u51b7\u6c34\u529f\u80fd\uff08\u51b7\u51dd\u7089\uff09\u53ef\u8bbe\u7f6e\u4e3a\u6301\u7eed\u9884\u70ed\u6a21\u5f0f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70b9\u706b\u5931\u8d25\/\u7184\u706b\u4fdd\u62a4\u62a5\u8b66<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2460 \u786e\u8ba4\u71c3\u6c14\u9600\u5f00\u542f\u4e14\u6709\u6c14\uff08\u67e5\u53a8\u623f\u7076\u662f\u5426\u6709\u706b\uff09 \u2461 \u7b49\u5f855\u5206\u949f\u540e\u91cd\u65b0\u70b9\u706b \u2462 \u68c0\u67e5\u70df\u7ba1\u662f\u5426\u5835\u585e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8054\u7cfb\u9f99\u8109\u6696\u901a\u552e\u540e\uff0c\u52ff\u81ea\u884c\u62c6\u673a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7089\u4f53\u6216\u7ba1\u9053\u6e17\u6c34<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2460 \u7acb\u5373\u5173\u95ed\u8fdb\u6c34\u9600 \u2461 \u5173\u95ed\u7535\u6e90 \u2462 \u62cd\u7167\u8bb0\u5f55\u6e17\u6c34\u4f4d\u7f6e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c\u4e00\u65f6\u95f4\u8054\u7cfb\u552e\u540e\uff0c\u4e0d\u8981\u5f3a\u884c\u4fee\u590d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.4 \u4fdd\u517b\u65e5\u5386<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5468\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u505a\u4ec0\u4e48<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u81ea\u5df1\u6765\u8fd8\u662f\u627e\u6211\u4eec\uff1f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u6708<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u7cfb\u7edf\u6c34\u538b\uff08\u6b63\u5e381-2bar\uff09\uff1b\u68c0\u67e5\u71c3\u6c14\u6cc4\u6f0f\u62a5\u8b66\u5668\u6307\u793a\u706f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u81ea\u5df1\u52a8\u624b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5b63<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e05\u6d01\u7089\u4f53\u8868\u9762\uff1b\u786e\u8ba4\u5206\u96c6\u6c34\u5668\u5404\u56de\u8def\u65cb\u94ae\u4e0d\u5361\u6b7b\uff1b\u68c0\u67e5\u6e29\u63a7\u5668\u7535\u6c60<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u81ea\u5df1\u52a8\u624b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e13\u4e1a\u6e05\u6d17\u6362\u70ed\u5668\uff1b\u68c0\u67e5\u5b89\u5168\u9600\uff08\u624b\u52a8\u6cc4\u538b\u6d4b\u8bd5\uff09\uff1b\u68c0\u67e5\u81a8\u80c0\u6c34\u7bb1\u9884\u5145\u538b\u529b\uff1b\u71c3\u6c14\u7cfb\u7edf\u68c0\u6f0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u8054\u7cfb\u6211\u4eec<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf2\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66f4\u6362\u78c1\u6027\u8fc7\u6ee4\u5668\u6ee4\u82af\uff1b\u51b7\u51dd\u7089\u6e05\u6d01\u51b7\u51dd\u6c34\u7ba1\u8def\uff1b\u68c0\u67e5\u6c34\u6cf5\u53f6\u8f6e\u662f\u5426\u5361\u963b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u8054\u7cfb\u6211\u4eec<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.5 \u78c1\u6027\u8fc7\u6ee4\u5668\u8017\u6750\u6307\u5357<\/h3>\n\n<h4 class=\"wp-block-heading\">\u4e3a\u4ec0\u4e48\u9700\u8981\u5b9a\u671f\u66f4\u6362\/\u6e05\u6d17\uff1f<\/h4>\n\n<p class=\"wp-block-paragraph\">\u6696\u901a\u884c\u4e1a\u5b58\u5728\u4e00\u4e2a\u666e\u904d\u95ee\u9898\uff1a\u5b89\u88c5\u65f6\u52a0\u4e86\u78c1\u6027\u9664\u6c61\u8fc7\u6ee4\u5668\uff0c\u4f46\u4ece\u6765\u6ca1\u4eba\u544a\u8bc9\u7528\u6237\u9700\u8981\u5b9a\u671f\u6e05\u6d17\u3002\u51e0\u5e74\u540e\u8fc7\u6ee4\u5668\u5438\u6ee1\u94c1\u9508\u548c\u6c34\u57a2\uff0c\u7ba1\u8def\u5835\u585e\uff0c\u5faa\u73af\u6cf5\u53d7\u635f\uff0c\u6700\u540e\u53d8\u6210\u4e00\u7b14\u51e0\u5343\u5143\u7684\u5927\u4fee\u8d39\u7528\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u7684\u505a\u6cd5\u4e0d\u540c<\/strong>\uff1a\u6bcf\u6b21\u5e74\u5ea6\u4fdd\u517b\uff0c\u6211\u4eec\u4f1a\u4e3b\u52a8\u68c0\u67e5\u5e76\u6e05\u6d17\u6216\u66f4\u6362\u8fc7\u6ee4\u5668\u6ee4\u82af\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">\u6e05\u6d17\u64cd\u4f5c\u6b65\u9aa4<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6b65\u9aa4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u58c1\u6302\u7089\uff0c\u7b49\u5f85\u7cfb\u7edf\u538b\u529b\u964d\u81f30<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u8fc7\u6ee4\u5668\u524d\u540e\u622a\u6b62\u9600<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6253\u5f00\u6392\u6c61\u53e3\uff0c\u6392\u5c3d\u79ef\u6c34<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62e7\u4e0b\u78c1\u68d2\uff0c\u6e05\u6d17\u5438\u9644\u7684\u94c1\u9508\u548c\u78c1\u6027\u9897\u7c92<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e05\u6d17\u5916\u58f3\u5185\u58c1\uff0c\u51b2\u51c0\u540e\u88c5\u56de<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62e7\u7d27\u6392\u6c61\u53e3\uff0c\u5f00\u542f\u622a\u6b62\u9600\uff0c\u91cd\u65b0\u6ce8\u6c34\u81f3\u6b63\u5e38\u6c34\u538b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f00\u673a\u8fd0\u884c10\u5206\u949f\uff0c\u68c0\u67e5\u5bc6\u5c01\u5904\u65e0\u6e17\u6f0f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1 \u66f4\u6362\u4fe1\u53f7\uff1a\u2460 \u7cfb\u7edf\u6c34\u538b\u9891\u7e41\u4e0b\u964d\u4f46\u65e0\u6f0f\u6c34 \u2461 \u5faa\u73af\u6cf5\u58f0\u97f3\u6bd4\u5e73\u65f6\u5927 \u2462 \u5e74\u5ea6\u4fdd\u517b\u65f6\u53d1\u73b0\u78c1\u68d2\u4e25\u91cd\u79ef\u57a2<\/p>\n<\/blockquote>\n\n<h4 class=\"wp-block-heading\">\u8017\u6750\u5bff\u547d\u4e0e\u8d39\u7528\u53c2\u8003<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u505a\u7ef4\u62a4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u671f\u6e05\u6d17\uff08\u9f99\u8109\u4fdd\u517b\u5305\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u8fc7\u6ee4\u5668\u5bff\u547d<\/td><td class=\"has-text-align-left\" data-align=\"left\">3-5\u5e74\uff08\u4e25\u91cd\u5835\u585e\u540e\u9700\u6574\u4f53\u66f4\u6362\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ef\u752810\u5e74\u4ee5\u4e0a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5faa\u73af\u6cf5\u98ce\u9669<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6742\u8d28\u5165\u6cf5\uff0c\u53f6\u8f6e\u53d7\u635f\uff0c\u7ef4\u4fee\u8d39500-1,500\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6781\u4f4e\u98ce\u9669<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u7ef4\u62a4\u8d39\u7528<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ef\u80fd\u51fa\u73b01-2\u6b21\u5927\u4fee\uff0c\u5171\u8ba11,500-5,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74\u4fdd\u517b200-300\u5143\uff0c10\u5e74\u7ea62,000-3,000\u5143\uff0c\u4e14\u65e0\u5927\u4fee\u98ce\u9669<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<!-- \u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u00b7 \u8865\u5145\u7248\uff08\u7c98\u8d34\u5230 page_id=1841 \u73b0\u6709\u533a\u5757\u672b\u5c3e\u6216\u72ec\u7acb\u81ea\u5b9a\u4e49HTML\u533a\u5757\uff09 -->\n<!-- \u8bf4\u660e\uff1a\u672c\u5757\u4e3a\"\u8865\u5145\"\uff0c\u4e0d\u8986\u76d6\u4f60\u5df2\u53d1\u5e03\u7684\u7535\u5b50\u4e66\u6b63\u6587\uff1b\u542b\u4ea7\u54c1\u56fe\u9274\/\u4ef7\u683c\u901f\u67e5\/\u5185\u94fe\/GEO\/FAQ\/\u53cc\u95e8\u5e97\u5361 -->\n<div class=\"lm-sup\">\n<style>\n.lm-sup{max-width:900px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#2c3e3e;line-height:1.7;}\n.lm-sup h2{font-size:21px;color:#12314F;margin:26px 0 12px;border-left:5px solid #E8541E;padding-left:12px;}\n.lm-sup h3{font-size:16px;color:#1f4d45;margin:14px 0 8px;}\n.lm-sup .lm-sup-gallery{display:grid;grid-template-columns:repeat(auto-fill,minmax(150px,1fr));gap:12px;margin:14px 0;}\n.lm-sup .lm-sup-gallery figure{margin:0;background:#fff;border:1px solid #e2e8e6;border-radius:10px;overflow:hidden;}\n.lm-sup .lm-sup-gallery img{width:100%;height:auto;display:block;}\n.lm-sup .lm-sup-gallery figcaption{font-size:12.5px;color:#475569;padding:8px 10px;}\n.lm-sup table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14px;background:#fff;}\n.lm-sup th,.lm-sup td{border:1px solid #d8e3e0;padding:9px 11px;text-align:left;}\n.lm-sup th{background:#12314F;color:#fff;font-weight:600;}\n.lm-sup tr:nth-child(even) td{background:#f5f9f8;}\n.lm-sup .inq{background:#fff7ed;border:1px solid #fdba74;border-left:5px solid #E8541E;border-radius:10px;padding:12px 16px;margin:14px 0;color:#7c2d12;font-size:14.5px;}\n.lm-sup .inq strong{color:#c2410c;}\n.lm-sup .inq a{color:#c2410c;border-bottom:1px solid #fdba74;font-weight:700;}\n.lm-sup .lm-sup-links{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:12px;margin:14px 0;}\n.lm-sup .lm-sup-links a{display:block;background:#fff;border:1px solid #d8e3e0;border-radius:10px;padding:12px 14px;color:#1f4d45;text-decoration:none;font-weight:600;font-size:14px;transition:.2s;}\n.lm-sup .lm-sup-links a:hover{border-color:#E8541E;box-shadow:0 2px 10px rgba(232,84,30,.12);}\n.lm-sup .lm-sup-links a span{display:block;font-weight:400;font-size:12px;color:#647b76;margin-top:3px;}\n.lm-sup .lm-sup-case{border-left:4px solid #E8541E;background:#fff7ed;padding:12px 16px;border-radius:0 10px 10px 0;margin:14px 0;font-size:14px;color:#7c2d12;}\n.lm-sup .lm-sup-case a{color:#c2410c;font-weight:700;}\n.lm-sup details{border:1px solid #d8e3e0;background:#fff;border-radius:10px;padding:0 14px;margin:8px 0;}\n.lm-sup summary{cursor:pointer;padding:12px 0;font-weight:600;color:#1f4d45;}\n.lm-sup details p{padding:0 0 12px;color:#475569;}\n.lm-sup .lm-sup-store{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:14px 0;}\n.lm-sup .lm-sup-store .st{background:#fff;border:1px solid #e2e8e6;border-radius:12px;padding:14px;}\n.lm-sup .lm-sup-store .st h4{margin:0 0 8px;color:#12314F;}\n.lm-sup .lm-sup-store .mgr{font-size:14px;color:#475569;margin:5px 0;}\n.lm-sup .lm-sup-store .mgr a{color:#1d4ed8;border-bottom:1px solid #c7d2fe;font-weight:700;}\n.lm-sup .lm-sup-store .hotline{display:inline-block;margin:8px 0 4px;font-size:18px;font-weight:800;color:#E8541E;background:#fff;border:2px solid #E8541E;border-radius:8px;padding:6px 14px;}\n.lm-sup .lm-sup-store .hotline a{color:#E8541E;border-bottom:none;}\n.lm-sup .lm-sup-store .nav{margin:7px 0 2px;font-size:13.5px;}\n.lm-sup .lm-sup-store .nav a{color:#1d4ed8;border-bottom:1px solid #c7d2fe;font-weight:700;}\n<\/style>\n\n<h2>\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u00b7 \u4ea7\u54c1\u56fe\u9274<\/h2>\n<p style=\"font-size:13px;color:#647b76;margin:0 0 6px;\">\u56fe\u7247\u5747\u6765\u81ea\u9f99\u8109\u5b98\u7f51\u5a92\u4f53\u5e93\uff082026-08 \u6574\u7406\uff09\uff0c\u70b9\u51fb\u53ef\u770b\u5927\u56fe\u3002<\/p>\n<div class=\"lm-sup-gallery\">\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E6%9B%BC%E7%91%9E%E5%BE%B7-LL1GQ24-KA.2428min4%E5%85%A8%E9%A2%84%E6%B7%B7%E5%86%B7%E5%87%9D%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E7%83%AD%E6%B0%B4%E7%82%89%E6%B7%B7%E5%86%B7%E5%87%9D%E5%A3%81%E6%8C%82%E7%82%89-%E9%9B%85%E5%A3%AB%E7%99%BD%E9%9B%B6%E5%86%B7%E6%B0%B4.png\" alt=\"\u66fc\u745e\u5fb7 \u5168\u9884\u6df7\u51b7\u51dd LL1GQ24 \u96c5\u58eb\u767d\u96f6\u51b7\u6c34\"><figcaption>\u5168\u9884\u6df7\u51b7\u51dd LL1GQ24 \u96c5\u58eb\u767d\u96f6\u51b7\u6c34<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E6%9B%BC%E7%91%9E%E5%BE%B7-%E5%85%A8%E9%A2%84%E6%B7%B7%E5%86%B7%E5%87%9D%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E5%A3%81%E6%8C%82%E7%82%89LL1GQ2428-%E9%BB%91%E6%99%B6%E7%8E%89.png\" alt=\"\u66fc\u745e\u5fb7 \u5168\u9884\u6df7\u51b7\u51dd LL1GQ2428 \u9ed1\u6676\u7389\"><figcaption>\u5168\u9884\u6df7\u51b7\u51dd LL1GQ2428 \u9ed1\u6676\u7389<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E6%9B%BC%E7%91%9E%E5%BE%B7-%E5%85%A8%E9%A2%84%E6%B7%B7%E5%86%B7%E5%87%9D%E7%87%83%E6%B0%94%E9%87%87%E6%9A%96%E5%A3%81%E6%8C%82%E7%82%89LL1GQ3632-%E9%BB%91%E6%99%B6%E7%8E%89.png\" alt=\"\u66fc\u745e\u5fb7 \u5168\u9884\u6df7\u51b7\u51dd LL1GQ3632 \u9ed1\u6676\u7389\"><figcaption>\u5168\u9884\u6df7\u51b7\u51dd LL1GQ3632 \u9ed1\u6676\u7389<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E6%9B%BC%E7%91%9E%E5%BE%B7-%E5%B0%8F%E5%8D%A1%E5%85%A8%E9%A2%84%E6%B7%B7%E5%86%B7%E5%87%9D%E5%A3%81%E6%8C%82%E7%82%89LL1GQ2428-%E7%9F%BF%E7%9F%B3%E7%99%BD.png\" alt=\"\u66fc\u745e\u5fb7 \u5c0f\u5361\u5168\u9884\u6df7\u51b7\u51dd LL1GQ2428 \u77ff\u77f3\u767d\"><figcaption>\u5c0f\u5361\u5168\u9884\u6df7\u51b7\u51dd LL1GQ2428 \u77ff\u77f3\u767d<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/%E6%9B%BC%E7%91%9E%E5%BE%B7-%E5%B0%8F%E5%8D%A1%E5%85%A8%E9%A2%84%E6%B7%B7%E5%86%B7%E5%87%9D%E5%A3%81%E6%8C%82%E7%82%89LL1GQ3632-%E7%9F%BF%E7%9F%B3%E7%99%BD.png\" alt=\"\u66fc\u745e\u5fb7 \u5c0f\u5361\u5168\u9884\u6df7\u51b7\u51dd LL1GQ3632 \u77ff\u77f3\u767d\"><figcaption>\u5c0f\u5361\u5168\u9884\u6df7\u51b7\u51dd LL1GQ3632 \u77ff\u77f3\u767d<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-bpfdrqcnrsl-L1PB18-HI.Pro_.png\" alt=\"\u66fc\u745e\u5fb7 \u53d8\u9891\u5206\u6bb5\u71c3\u6c14\u91c7\u6696\u70ed\u6c34\u7089 L1PB18-HI.Pro\uff08\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u7814\uff09\"><figcaption>\u53d8\u9891\u5206\u6bb5 L1PB18-HI.Pro\uff08\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u7814\uff0c18kW\uff09<\/figcaption><\/figure>\n  <figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\" alt=\"\u66fc\u745e\u5fb7 \u6d77\u5fb7\u5821\u53d8\u9891\u5206\u6bb5\u4e24\u7528\u7089 L1PB24-Heidelberg\"><figcaption>\u6d77\u5fb7\u5821\u53d8\u9891\u5206\u6bb5\u4e24\u7528\u7089 L1PB24-Heidelberg\uff0824kW\uff09<\/figcaption><\/figure>\n<\/div>\n\n<h2>\u66fc\u745e\u5fb7\u58c1\u6302\u7089 \u00b7 \u53c2\u8003\u4ef7\u683c<\/h2>\n<table>\n<thead><tr><th>\u578b\u53f7<\/th><th>\u529f\u7387<\/th><th>\u7c7b\u578b<\/th><th>\u9f99\u8109\u53c2\u8003\u4ef7\uff082026\uff09<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>L1PB18-HI.Pro\uff08\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u7814\uff09<\/td><td>18kW<\/td><td>\u53d8\u9891\u5355\u91c7\u6696<\/td><td>\u00a54,666<\/td><\/tr>\n<tr><td>\u5c0f\u5361\u51b7\u51dd\u7089 LL1GQ24\/36-KA<\/td><td>24\/36kW<\/td><td>\u5168\u9884\u6df7\u51b7\u51dd\u4e24\u7528<\/td><td>\u00a510,900\uff08\u533a\u95f4 \u00a58,000\u201311,000\uff09<\/td><\/tr>\n<tr><td>\u6d77\u5fb7\u5821 \/ \u70ed\u5c9b \u666e\u901a\u7089<\/td><td>18\u201340kW<\/td><td>\u5927\u6c14\u5f0f\u5e38\u89c4<\/td><td>\u00a54,000\u20136,000<\/td><\/tr>\n<\/tbody>\n<\/table>\n<div class=\"inq\">\ud83d\udcde <strong>\u4e0a\u8868\u4e3a\u9f99\u8109\u4e3b\u63a8\u578b\u53f7\u53c2\u8003\u4ef7<\/strong>\uff1b\u6700\u7ec8\u6210\u4ea4\u968f\u914d\u7f6e\u3001\u6d3b\u52a8\u4e0e\u9f99\u8109\u4e13\u5c5e\u4f18\u60e0\u6d6e\u52a8\u3002\u5b8c\u6574\u578b\u53f7\u4ef7\u76ee\u4e0e\u4f18\u60e0\u4ef7\uff0c\u8bf7\u89c1 <a href=\"?page_id=11082\">\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b<\/a>\uff0c\u6216\u62e8\u6253\u95e8\u5e97\u70ed\u7ebf <a href=\"tel:02886131795\">028-86131795<\/a> \/ <a href=\"tel:02865272586\">028-65272586<\/a> \u514d\u8d39\u52d8\u6d4b\u62a5\u4ef7\u3002<\/div>\n\n<h2>\u76f8\u5173\u58c1\u6302\u7089\u4e13\u9898\uff08\u5185\u94fe\u5bfc\u822a\uff09<\/h2>\n<div class=\"lm-sup-links\">\n  <a href=\"?page_id=11082\">\u58c1\u6302\u7089\u591a\u5c11\u94b1<span>\u5168\u54c1\u724c\u4ef7\u683c + \u9f99\u8109\u4f18\u60e0\u4ef7<\/span><\/a>\n  <a href=\"?page_id=11074\">\u58c1\u6302\u7089\u600e\u4e48\u9009<span>\u51b7\u51dd\/\u5e38\u89c4\u00b7\u529f\u7387\u00b7\u54c1\u724c\u6a2a\u8bc4<\/span><\/a>\n  <a href=\"?page_id=835\">\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5<span>\u5fb7\u7cfb\u591a\u7ebf\u9009\u578b<\/span><\/a>\n  <a href=\"?page_id=1824\">\u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5<span>\u51b7\u51dd\u6280\u672f\u6807\u6746<\/span><\/a>\n  <a href=\"?page_id=2489\">\u6797\u5185\u58c1\u6302\u7089\u8be6\u60c5<span>\u65e5\u7cfb\u6052\u6e29\u70ed\u6c34<\/span><\/a>\n  <a href=\"?page_id=10970\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4ef7\u683c<span>\u7efc\u5408\u53c2\u8003\u4ef7<\/span><\/a>\n  <a href=\"?page_id=10975\">\u4e24\u8054\u4f9b\u53c2\u8003\u4ef7\u683c<span>\u805a\u5408\u9875<\/span><\/a>\n  <a href=\"?page_id=10977\">\u5730\u6696\u53c2\u8003\u4ef7\u683c<span>\u5730\u6696\u65b9\u6848<\/span><\/a>\n  <a href=\"?page_id=10982\">\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c<span>\u660e\u88c5\u5957\u9910<\/span><\/a>\n<p>\u58c1\u6302\u7089\u5728\u70ed\u6c34\u7cfb\u7edf\u91cc\u7684\u89d2\u8272\uff08\u4e24\u7528\u7089\u4e0e\u7cfb\u7edf\u7089+\u6c34\u7bb1\u600e\u4e48\u9009\u3001\u71c3\u6c14\u8868\u6821\u6838\uff09\uff0c\u89c1<a href=\"https:\/\/longmai-nt.com\/?page_id=1879\">\u5bb6\u7528\u70ed\u6c34\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7<\/a>\u3002<\/p>\n\n<\/div>\n\n<div class=\"lm-sup-case\">\n\ud83d\udcce <strong>\u6848\u4f8b\u5206\u4eab\uff1a<\/strong>\u672c\u7ae0\u6b63\u6587\u5df2\u542b 3 \u4e2a\u6210\u90fd\u771f\u5b9e\u6237\u578b\u6848\u4f8b\uff08\u91d1\u725b100\u33a1\u5730\u6696\u6539\u9020 \/ \u9ad8\u65b0160\u33a1\u51b7\u51dd\u7089 \/ \u6b66\u4faf\u65e7\u623f\u6696\u6c14\u7247\u7f6e\u6362\uff09\uff1b\u66f4\u591a\u54c1\u724c\u5bf9\u6bd4\u53ef\u770b <a href=\"?page_id=1824\">\u83f2\u65af\u66fc\u51b7\u51dd\u7089\u8282\u80fd\u5b9e\u6d4b<\/a>\uff0c\u771f\u5b9e\u6210\u4ea4\u53c2\u8003\u89c1 <a href=\"?page_id=11082\">\u300a\u58c1\u6302\u7089\u591a\u5c11\u94b1\u300b<\/a>\u3002<br>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=15069\">\u5e7f\u6c49 57\u33a1 \u4e24\u5ba4\u4e00\u5385\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff08\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089\uff09<\/a>\n\n<\/div>\n\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n<details><summary>\u5c0f\u6237\u578b\u5730\u6696\u4e3a\u4ec0\u4e48\u63a8 L1PB18-HI.Pro\uff1f<\/summary><p>\u4f20\u7edf 24kW \u7089\u6700\u5c0f\u8f93\u51fa 8\u201310kW\uff0c\u8fdc\u8d85\u5c0f\u6237\u578b\u5730\u6696 3\u20135kW \u6052\u6e29\u8d1f\u8377\uff0c\u5bfc\u81f4\u9891\u7e41\u542f\u505c\u3002L1PB18 \u6700\u5c0f\u8f93\u51fa\u4ec5 5.6kW\uff0c\u662f\u9f99\u8109\u00d7\u66fc\u745e\u5fb7\u8054\u5408\u7814\u53d1\uff0c\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u6253\u9020\uff0c\u89c1\u6b63\u6587\u7b2c\u56db\u7ae0\u6848\u4f8b\u4e00\u3002<\/p><\/details>\n<details><summary>\u51b7\u51dd\u7089\u6bd4\u666e\u901a\u7089\u8d35\uff0c\u503c\u5f97\u5417\uff1f<\/summary><p>\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387 108%\u30011:8 \u8c03\u8282\u6bd4\u30018 \u5e74\u6574\u673a\u4fdd\u4fee\uff1b\u4ee5 140\u33a1 \u8ba1\uff0c8 \u5e74\u7701\u6c14\u7ea6 4,800\u20138,000 \u5143\uff0c\u8986\u76d6\u521d\u59cb\u6ea2\u4ef7\u3002\u666e\u901a\u7089\u4ec5 2\u20133 \u5e74\u4fdd\u4fee\u3002\u8be6\u89c1\u6b63\u6587 4.4\u3002<\/p><\/details>\n<details><summary>\u58c1\u6302\u7089\u80fd\u88c5\u6a71\u67dc\u91cc\u5417\uff1f<\/summary><p>\u4e0d\u80fd\u3002\u9700\u901a\u98ce\u826f\u597d\uff08\u53a8\u623f\/\u9633\u53f0\uff09\uff0c\u4e24\u4fa7\u8ddd\u5899\u2265200mm\u3001\u524d\u65b9\u65e0\u906e\u6321\u3001\u7981\u5c01\u95ed\u5f0f\u6a71\u67dc\uff0c\u5426\u5219\u6613\u62a5\u8b66\u751a\u81f3\u4e00\u6c27\u5316\u78b3\u79ef\u805a\u3002\u8be6\u89c1\u6b63\u6587\u5b89\u88c5\u89c4\u8303\u3002<\/p><\/details>\n\n<h2>\u95e8\u5e97\u54a8\u8be2 \u00b7 \u9500\u552e\u7535\u8bdd<\/h2>\n<div class=\"lm-sup-store\">\n  <div class=\"st\">\n    <h4>\u5357\u5bcc\u68ee \u00b7 \u9ad8\u65b0\u5e97<\/h4>\n    <p>\ud83d\udccd \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/p>\n    <p class=\"nav\">\ud83d\uddfa <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892|30.598786|104.074284|30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97 \u203a<\/a><\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u8303\u7ecf\u7406\uff1a<a href=\"tel:13398198375\">133-9819-8375<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u90ed\u7ecf\u7406\uff1a<a href=\"tel:18100839248\">181-0083-9248<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"hotline\"><a href=\"tel:02886131795\">028-86131795<\/a><\/p>\n    <p style=\"font-size:12px;color:#94a3b8;\">\u5357\u5bcc\u68ee\u70ed\u7ebf \u00b7 \u5168\u5929\u5019\u670d\u52a1<\/p>\n  <\/div>\n  <div class=\"st\">\n    <h4>\u5317\u5bcc\u68ee \u00b7 \u6210\u534e\u5e97<\/h4>\n    <p>\ud83d\udccd \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/p>\n    <p class=\"nav\">\ud83d\uddfa <a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547|30.599807|104.07041|30.604665&amp;query_type=IDQ&amp;query=%E6%88%90%E9%83%BD%E6%97%A5%E7%AB%8B%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%99%BA%E6%85%A7%E7%A9%BA%E6%B0%94%E9%A6%86(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8C%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17.5\" target=\"_blank\" rel=\"noopener\">\u9ad8\u5fb7\u5bfc\u822a\u5230\u5e97 \u203a<\/a><\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u9ec4\u7ecf\u7406\uff1a<a href=\"tel:15828489188\">158-2848-9188<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"mgr\">\ud83d\udcf1 \u4f59\u7ecf\u7406\uff1a<a href=\"tel:13908183204\">139-0818-3204<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n    <p class=\"hotline\"><a href=\"tel:02865272586\">028-65272586<\/a><\/p>\n    <p style=\"font-size:12px;color:#94a3b8;\">\u5317\u5bcc\u68ee\u70ed\u7ebf \u00b7 \u5168\u5929\u5019\u670d\u52a1<\/p>\n  <\/div>\n<\/div>\n<\/div>\n\n<section style=\"margin:28px 0;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,'PingFang SC','Microsoft YaHei',sans-serif;\">\n  <h2 style=\"font-size:1.5em;color:#12314F;border-left:4px solid #E8541E;padding-left:12px;margin:0 0 16px;\">\u76f8\u5173\u9605\u8bfb \u00b7 \u9009\u8d2d\u4e0e\u65b9\u6848\u5bfc\u822a<\/h2>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(240px,1fr));gap:14px;\">\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=11074\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u58c1\u6302\u7089\u600e\u4e48\u9009\uff1f\u6210\u90fd\u5bb6\u5ead\u9009\u8d2d\u907f\u5751\u6307\u5357<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u529f\u7387 \/ \u7c7b\u578b \/ \u51b7\u51dd\u7089\u9009\u8d2d\u67a2\u7ebd\u9875<\/div>\n    <\/a>\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=11082\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u58c1\u6302\u7089\u591a\u5c11\u94b1\uff1f2026 \u6210\u90fd\u53c2\u8003\u62a5\u4ef7<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u542b\u5b89\u88c5 \u00b7 \u4e3b\u673a\u53c2\u8003\u4ef7\u805a\u5408\u9875<\/div>\n    <\/a>\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=4499\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u66fc\u745e\u5fb7 HI.PRO \u5355\u91c7\u6696\u53d8\u9891\u7089\uff0818kW\uff09<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u5c0f\u529f\u7387\u53d8\u9891 \u00b7 \u5730\u6696 \/ \u660e\u88c5\u4e13\u7528\u5355\u54c1\u9875<\/div>\n    <\/a>\n\n    <!-- \u300c\u660e\u88c5\u6696\u6c14\u00b7\u5c0f\u529f\u7387\u53d8\u9891\u7089\u9009\u578b\u300d\u843d\u5730\u9875\uff0c\u94fe\u63a5\u5df2\u56de\u586b page_id=12776 -->\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=12776\" style=\"display:block;padding:14px 16px;border:1px solid #E8541E;border-radius:10px;text-decoration:none;color:#12314F;background:#fff7f2;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u660e\u88c5\u6696\u6c14 \u00b7 \u5c0f\u529f\u7387\u53d8\u9891\u7089\u9009\u578b\u6307\u5357<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u5c0f\u6237\u578b \/ \u8001\u623f\u660e\u88c5\u4e3a\u4f55\u8981\u9009\u5c0f\u529f\u7387<\/div>\n    <\/a>\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=10982\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c\u4e0e\u65b9\u6848<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u8001\u623f \/ \u7cbe\u88c5\u623f\u660e\u88c5\u62a5\u4ef7\u4e0e\u5de5\u671f<\/div>\n    <\/a>\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=12447\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u70ed\u6e90\u9009\u578b \/ \u7cfb\u7edf\u8bbe\u8ba1 \/ \u65bd\u5de5\u9a8c\u6536 \/ 20 \u5e74\u6210\u672c<\/div>\n    <\/a>\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=12439\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u5730\u6696\u7cfb\u7edf\u767d\u76ae\u4e66<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u5730\u6696\u84c4\u70ed\u79d1\u5b66\u4e0e\u7cfb\u7edf\u914d\u7f6e\u6df1\u5ea6\u79d1\u666e<\/div>\n    <\/a>\n\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2137\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u6696\u6c14\u7247\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7<\/div>\n      <\/div>\n    <\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=13971\" style=\"display:block;padding:14px 16px;border:1px solid #e2e8f0;border-radius:10px;text-decoration:none;color:#12314F;background:#fff;\">\n      <div style=\"font-weight:600;line-height:1.4;\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u5957\u9910\u591a\u5c11\u94b1\uff082026 \u4e09\u6863\u4e00\u4ef7\u5168\u5305\uff09<\/div>\n      <div style=\"font-size:.82em;color:#94a3b8;margin-top:5px;\">\u4e09\u6863\u6309\u9505\u7089\u5206\u6863\uff0c\u4e00\u4ef7\u5168\u5305\uff1a\u9505\u7089 + 4 \u7ec4\u6696\u6c14\u7247 + \u5168\u5957\u7ba1\u8def\u9600\u95e8 + \u6807\u51c6\u5b89\u88c5<\/div>\n    <\/a>\n\n  <\/div>\n<\/section>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">\u5e95\u90e8\uff1aCTA + \u670d\u52a1\u627f\u8bfa<\/h2>\n\n<p class=\"wp-block-paragraph\">\ud83c\udfaf <strong>\u73b0\u5728\u5c31\u884c\u52a8\uff0c\u62e5\u6709\u5c5e\u4e8e\u60a8\u7684\u5065\u5eb7\u91c7\u6696\u7cfb\u7edf\uff01<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u627f\u8bfa<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u514d\u8d39\u54a8\u8be2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8054\u7cfb\u6211\u4eec\uff0c\u5373\u53ef\u83b7\u5f971\u5bf91\u65b9\u6848\u8bbe\u8ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e13\u4e1a\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u8c28\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u9009\u578b\uff0c\u63d0\u4f9b1-2\u5957\u4f9b\u6696\u65b9\u6848<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cbe\u5de5\u5b89\u88c5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u683c\u6267\u884c\u7cbe\u5de5\u516d\u6b65\u6cd5\uff0c\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u80fd\u6e90\u4fdd\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u5165\u4f1a\u5458\u8ba1\u5212\uff0c\u9501\u5b9a\u672a\u676510\u5e74\u91c7\u6696\u80fd\u8017\uff0c\u8d85\u51fa\u90e8\u5206\u6211\u4eec\u627f\u62c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u670d\u52a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u7ef4\u62a4\u3001\u6bcf\u5e74\u4e00\u6b21\u514d\u8d39\u4f53\u68c0\u3001\u6545\u969c\u62a5\u4fee30\u5206\u949f\u54cd\u5e94\u30012\u5c0f\u65f6\u5185\u4e0a\u95e8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde \u5357\u5bcc\u68ee\u95e8\u5e97\uff1a<a href=\"tel:028-86131795\">028-86131795<\/a><br>\ud83d\udcde \u5317\u5bcc\u68ee\u95e8\u5e97\uff1a<a href=\"tel:028-65272586\">028-65272586<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">\ud83d\udccd \u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<br>\ud83d\udccd \u9f99\u8109\u6696\u901a\u00b7\u6210\u534e\u533a\u5e97\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"HomeAndConstructionBusiness\",\n  \"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n  \"description\":\"\u6210\u90fd\u65e5\u7acb\u94bb\u77f3\u6388\u6743\u670d\u52a1\u5546\uff0c\u4e2d\u592e\u7a7a\u8c03\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u4e24\u8054\u4f9b\u3001\u58c1\u6302\u7089\u4e0a\u95e8\u52d8\u6d4b\u8bbe\u8ba1\u5b89\u88c5\",\n  \"telephone\":\"028\u201186131795\",\n  \"address\":{\"@type\":\"PostalAddress\",\"addressRegion\":\"\u56db\u5ddd\u7701\u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u5bcc\u68ee\u7f8e3\u697cA348\"},\n  \"areaServed\":[\"\u9ad8\u65b0\u533a\",\"\u5929\u5e9c\u65b0\u533a\",\"\u6210\u534e\u533a\",\"\u9f99\u6cc9\u9a7f\",\"\u65b0\u90fd\u533a\",\"\u9752\u7f8a\u533a\",\"\u53cc\u6d41\u533a\",\"\u90eb\u90fd\u533a\"],\n  \"openingHours\":\"09:00\u201120:00 \u6696\u901a\u4e0a\u95e8\u52d8\u6d4b\",\n  \"sameAs\":\"https:\/\/longmai\u2011nt.com\",\n  \"hasMap\":[\n    \"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&city=510107&geoobj=104.05892|30.598786|104.074284|30.605656&query_type=IDQ&query=\u65e5\u7acb\u53d8\u9891\u4e2d\u592e\u7a7a\u8c03\u65d7\u8230\u5e97(\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u5e97)&zoom=17\",\n    \"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&city=510108&geoobj=104.059547|30.599807|104.07041|30.604665&query_type=IDQ&query=\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u667a\u6167\u7a7a\u6c14\u9986(\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u5e97)&zoom=17.5\"\n  ]\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u5730\u6696\u914d\u666e\u901a\u7089\u8fd8\u662f\u51b7\u51dd\u7089\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u5c0f\u6237\u578b\u5730\u6696\uff08\u2264100\u33a1\uff09\uff0c\u9996\u9009N1PB18\u2011HI.Pro\uff0818kW\u53d8\u9891\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff09\uff1b\u5927\u6237\u578b\u5730\u6696\uff0c\u9996\u9009\u5c0f\u5361\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u7ea63kW\uff0c\u51b7\u51dd\u6548\u7387\u9ad8\uff09\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u6d77\u5fb7\u5821\u548c\u70ed\u5c9b\u6709\u4ec0\u4e48\u533a\u522b\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u540c\u5c5e\u5927\u6c14\u5f0f\u666e\u901a\u7089\uff08\u4e8c\u7ea7\u80fd\u6548\uff09\uff0c\u4e3b\u8981\u5dee\u5f02\u5728\u578b\u53f7\u8fed\u4ee3\u548c\u5916\u89c2\u5c3a\u5bf8\u3002\u540c\u529f\u7387\u4e0b\u6309\u4ef7\u683c\u548c\u5916\u89c2\u9009\u5373\u53ef\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"SUN\u7cfb\u5217\u4e09\u4e2a\u578b\u53f7\u600e\u4e48\u9009\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SUN S18\u5355\u91c7\u6696\u53ea\u4f9b\u6696\uff1bSH18\u4e24\u7528\u4f9b\u6696+\u6d17\u6fa1\uff1bSV18\u7cfb\u7edf\u7089\u9002\u5408\u5927\u6237\u578b\u5916\u63a5\u6c34\u7bb1\uff0c\u591a\u70b9\u7528\u6c34\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u5b89\u88c5\u4f4d\u7f6e\u53ef\u4ee5\u653e\u6a71\u67dc\u91cc\u5417\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u4e0d\u53ef\u4ee5\u3002\u5fc5\u987b\u5b89\u88c5\u5728\u901a\u98ce\u826f\u597d\u7684\u4f4d\u7f6e\uff0c\u4e24\u4fa7\u8ddd\u5899\u2265200mm\uff0c\u524d\u65b9\u65e0\u906e\u6321\uff0c\u4e25\u7981\u5c01\u95ed\u5f0f\u6a71\u67dc\u5185\u5b89\u88c5\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u70df\u7ba1\u6700\u957f\u80fd\u8d70\u591a\u8fdc\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u51b7\u51dd\u7089\u540c\u8f74\u70df\u7ba1\u6700\u957f8m\uff1b\u666e\u901a\u70894\u20115m\uff0c\u6bcf\u4e00\u4e2a90\u00b0\u5f2f\u5934\u6263\u51cf1m\u5f53\u91cf\u957f\u5ea6\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u4e3a\u4ec0\u4e48\u9f99\u8109\u7279\u610f\u63a8N1PB18\u2011HI.Pro\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u9f99\u8109\u4e0e\u66fc\u745e\u5fb7\u8054\u5408\u7814\u53d1\uff0c\u4e13\u95e8\u89e3\u51b3\u5c0f\u6237\u578b\u5730\u6696\uff0c\u4f20\u7edf24kW\u7089\u6700\u5c0f\u8f93\u51fa\u8fc7\u9ad8\u3001\u9891\u7e41\u542f\u505c\u884c\u4e1a\u75db\u70b9\uff0c18kW\u6700\u5c0f\u8f93\u51fa5.6kW\u3002\"}\n    }\n  ]\n}\n<\/script>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><em>\u672c\u6587\u6570\u636e\u6765\u6e90\uff1a\u66fc\u745e\u5fb7\u5b98\u65b9\u7528\u6237\u624b\u518c\u3001\u5b89\u88c5\u8bf4\u660e\u3001\u5b98\u7f51\u3001\u767e\u5ea6\u767e\u79d1\u3001\u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93\u3001\u80fd\u6548\u68c0\u6d4b\u62a5\u544a\u3002\u6240\u6709\u53c2\u6570\u4ee5\u66fc\u745e\u5fb7\u5b98\u65b9\u6700\u65b0\u53d1\u5e03\u4e3a\u51c6\u3002<\/em><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>1995 \u5e74\u66fc\u745e\u5fb7\u59cb\u4e8e\u7a7a\u8c03\u53ca\u5b89\u9632\u7cfb\u7edf\u96c6\u6210 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1841","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u9f99\u8109\u6696\u901a\u8054\u5408\u7814\u53d116\u5e74\u3002N1PB18-HI.Pro\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u5b9a\u5236\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\uff1b\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u30018\u5e74\u4fdd\u4fee\u30011:8\u8c03\u8282\u6bd4\u3002\u542b3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b\u3001\u516d\u95ee\u516d\u7b54\u30013\u4e2a\u771f\u5b9e\u6848\u4f8b\u3001\u78c1\u6027\u8fc7\u6ee4\u5668\u7ef4\u62a4\u6307\u5357\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u6388\u6743\u670d\u52a1\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u9f99\u8109\u6696\u901a\u8054\u5408\u7814\u53d116\u5e74\u3002N1PB18-HI.Pro\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u5b9a\u5236\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\uff1b\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u30018\u5e74\u4fdd\u4fee\u30011:8\u8c03\u8282\u6bd4\u3002\u542b3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b\u3001\u516d\u95ee\u516d\u7b54\u30013\u4e2a\u771f\u5b9e\u6848\u4f8b\u3001\u78c1\u6027\u8fc7\u6ee4\u5668\u7ef4\u62a4\u6307\u5357\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u6388\u6743\u670d\u52a1\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1841\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-21T06:31:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841\",\"name\":\"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\\\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\",\"datePublished\":\"2026-05-29T09:51:23+00:00\",\"dateModified\":\"2026-10-21T06:31:41+00:00\",\"description\":\"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u9f99\u8109\u6696\u901a\u8054\u5408\u7814\u53d116\u5e74\u3002N1PB18-HI.Pro\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u5b9a\u5236\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\uff1b\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u30018\u5e74\u4fdd\u4fee\u30011:8\u8c03\u8282\u6bd4\u3002\u542b3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b\u3001\u516d\u95ee\u516d\u7b54\u30013\u4e2a\u771f\u5b9e\u6848\u4f8b\u3001\u78c1\u6027\u8fc7\u6ee4\u5668\u7ef4\u62a4\u6307\u5357\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u6388\u6743\u670d\u52a1\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png\",\"width\":454,\"height\":781},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1841#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\\\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790 - \u9f99\u8109\u6696\u901a","description":"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u9f99\u8109\u6696\u901a\u8054\u5408\u7814\u53d116\u5e74\u3002N1PB18-HI.Pro\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u5b9a\u5236\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\uff1b\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u30018\u5e74\u4fdd\u4fee\u30011:8\u8c03\u8282\u6bd4\u3002\u542b3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b\u3001\u516d\u95ee\u516d\u7b54\u30013\u4e2a\u771f\u5b9e\u6848\u4f8b\u3001\u78c1\u6027\u8fc7\u6ee4\u5668\u7ef4\u62a4\u6307\u5357\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u6388\u6743\u670d\u52a1\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1841","og_locale":"zh_CN","og_type":"article","og_title":"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790 - \u9f99\u8109\u6696\u901a","og_description":"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u9f99\u8109\u6696\u901a\u8054\u5408\u7814\u53d116\u5e74\u3002N1PB18-HI.Pro\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u5b9a\u5236\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\uff1b\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u30018\u5e74\u4fdd\u4fee\u30011:8\u8c03\u8282\u6bd4\u3002\u542b3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b\u3001\u516d\u95ee\u516d\u7b54\u30013\u4e2a\u771f\u5b9e\u6848\u4f8b\u3001\u78c1\u6027\u8fc7\u6ee4\u5668\u7ef4\u62a4\u6307\u5357\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u6388\u6743\u670d\u52a1\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=1841","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-21T06:31:41+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1841","url":"https:\/\/longmai-nt.com\/?page_id=1841","name":"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=1841#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=1841#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","datePublished":"2026-05-29T09:51:23+00:00","dateModified":"2026-10-21T06:31:41+00:00","description":"\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff0c\u9f99\u8109\u6696\u901a\u8054\u5408\u7814\u53d116\u5e74\u3002N1PB18-HI.Pro\u4e13\u4e3a\u5c0f\u6237\u578b\u5730\u6696\u5b9a\u5236\uff0c\u6700\u5c0f\u8f93\u51fa5.6kW\uff0c\u89e3\u51b3\u9891\u7e41\u542f\u505c\uff1b\u5c0f\u5361\u51b7\u51dd\u7089\u70ed\u6548\u7387108%\u30018\u5e74\u4fdd\u4fee\u30011:8\u8c03\u8282\u6bd4\u3002\u542b3400W\u6781\u9650\u6d4b\u8bd5\u6545\u4e8b\u3001\u516d\u95ee\u516d\u7b54\u30013\u4e2a\u771f\u5b9e\u6848\u4f8b\u3001\u78c1\u6027\u8fc7\u6ee4\u5668\u7ef4\u62a4\u6307\u5357\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u6388\u6743\u670d\u52a1\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1841#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1841"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=1841#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/08\/mrd-hdbbpfdlyl-L1PB24-Heidelberg.png","width":454,"height":781},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1841#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6210\u90fd\u66fc\u745e\u5fb7\u58c1\u6302\u7089\uff5c\u51b7\u51dd\u7089\/\u53d8\u9891\u5355\u91c7\u6696\u7089\u5168\u7cfb\u5217\u9009\u578b\u89e3\u6790"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1841","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1841"}],"version-history":[{"count":19,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1841\/revisions"}],"predecessor-version":[{"id":15900,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1841\/revisions\/15900"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1841"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}