{"id":1919,"date":"2026-05-31T11:40:10","date_gmt":"2026-05-31T03:40:10","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1919"},"modified":"2026-06-02T10:54:55","modified_gmt":"2026-06-02T02:54:55","slug":"%e5%a4%a9%e5%ba%9c%e6%96%b0%e5%8c%ba%e5%a4%a7%e6%9e%97%e9%95%87%e5%be%90%e5%85%88%e7%94%9f%e4%ba%8c%e8%81%94%e4%be%9b%e5%8a%a0%e7%83%ad%e6%b0%b4","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1919","title":{"rendered":"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u57fa\u672c\u4fe1\u606f<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5b57\u6bb5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u6237\u59d3\u540d<\/td><td>\u5f90\u5148\u751f<\/td><\/tr><tr><td>\u9879\u76ee\u7c7b\u578b<\/td><td>\u81ea\u5efa\u623f\uff0c\u56db\u5c42\u697c\u5efa\u7b51<\/td><\/tr><tr><td>\u88c5\u4fee\u60c5\u51b5<\/td><td>\u4e00\u697c\u95e8\u9762\uff0c\u4e09\u56db\u697c\u5df2\u88c5\u4fee\u597d\uff0c<strong>\u672c\u6b21\u88c5\u4fee\u4e8c\u697c<\/strong><\/td><\/tr><tr><td>\u5c45\u4f4f\u60c5\u51b5<\/td><td>5\u4eba\uff08\u8001\u4eba+\u5c0f\u5b69\uff09<\/td><\/tr><tr><td>\u4fdd\u6e29\u60c5\u51b5<\/td><td><strong>\u65e0\u4fdd\u6e29<\/strong><\/td><\/tr><tr><td>\u7535\u6e90\u60c5\u51b5<\/td><td>\u81ea\u5efa\u623f\u6709\u4e09\u76f8\u7535\uff09<\/td><\/tr><tr><td>\u6c9f\u901a\u9636\u6bb5<\/td><td>\u65b9\u6848\u9700\u6c42\u91c7\u96c6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u73b0\u6709\u8bbe\u5907\u4e0e\u75db\u70b9<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u73b0\u72b6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u75db\u70b9<\/th><\/tr><\/thead><tbody><tr><td>\u697c\u4e0a\u7a7a\u8c03<\/td><td>\u683c\u529b<\/td><td><strong>\u6709\u4e00\u53f0\u4e0d\u592a\u51c9\u5feb<\/strong>\uff08\u5236\u51b7\u6548\u679c\u5dee\uff09<\/td><\/tr><tr><td>\u697c\u4e0a\u91c7\u6696<\/td><td>\u9505\u7089\u5e26\u6696\u6c14\u7247<\/td><td>\u672a\u660e\u786e\u75db\u70b9\uff0c\u4f46\u4e3b\u52a8\u60f3\u6362\u4e24\u8054\u4f9b\uff0c\u8bf4\u660e\u5bf9\u73b0\u6709\u91c7\u6696\u65b9\u5f0f\u4e0d\u6ee1\u610f<\/td><\/tr><tr><td>\u70ed\u6c34<\/td><td>\u672a\u660e\u786e<\/td><td><strong>\u5927\u6c34\u91cf\u3001\u6052\u6e29\u3001\u96f6\u51b7\u6c34<\/strong>\u9700\u6c42<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u672c\u6b21\u9700\u6c42\uff08\u4e8c\u697c\uff09<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5185\u673a\u9884\u4f30\uff1a7\u53f0<\/strong>\uff08\u5ba2\u5385+\u9910\u5385+5\u4e2a\u5367\u5ba4\uff09<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u9700\u6c42<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5206\u7c7b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9700\u6c42<\/th><\/tr><\/thead><tbody><tr><td><strong>\u7a7a\u8c03<\/strong><\/td><td>\u4e8c\u8054\u4f9b\uff08\u5929\u6c34\u5730\u6c34\u6216\u5929\u6c1f\u5730\u6c34\uff09\uff0c\u5236\u51b7\u6548\u679c\u597d\uff0c\u697c\u4e0a\u683c\u529b\u4e0d\u51c9\u5feb\u7684\u75db\u70b9\u4e0d\u80fd\u5728\u4e8c\u697c\u91cd\u6f14<\/td><\/tr><tr><td><strong>\u91c7\u6696<\/strong><\/td><td>\u4e8c\u8054\u4f9b\u5730\u6696\uff0c\u66ff\u4ee3\u9505\u7089\u6696\u6c14\u7247<\/td><\/tr><tr><td><strong>\u70ed\u6c34<\/strong><\/td><td>\u5927\u6c34\u91cf\u3001\u6052\u6e29\u3001\u96f6\u51b7\u6c34<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u8981\u6c42<\/strong><\/td><td>\u81ea\u5efa\u623f\u65e0\u4fdd\u6e29\uff0c\u9700\u6309\u9ad8\u6807\u51c6\u914d\u7f6e\u51b7\u70ed\u8d1f\u8377<\/td><\/tr><tr><td><strong>\u5176\u4ed6<\/strong><\/td><td>\u6709\u8001\u4eba\u5c0f\u5b69\uff0c\u5bf9\u8212\u9002\u5ea6\u8981\u6c42\u9ad8\uff0c\u51fa\u98ce\u4e0d\u80fd\u592a\u51b7\u3001\u4e0d\u80fd\u76f4\u5439<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u6ce8\u610f\u4e8b\u9879<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td><strong>\u51b7\u8d1f\u8377<\/strong><\/td><td>\u81ea\u5efa\u623f\u65e0\u4fdd\u6e29 + \u5c42\u9ad8\u53ef\u80fd\u8f83\u9ad8\uff0c\u9700\u6309\u9ad8\u6807\u51c6\u8ba1\u7b97\uff08\u5efa\u8bae150-220W\/\u33a1\uff09<\/td><\/tr><tr><td><strong>\u897f\u6652\/\u73bb\u7483<\/strong><\/td><td>\u9700\u73b0\u573a\u786e\u8ba4\uff08\u81ea\u5efa\u623f\u5916\u5899\u591a\uff0c\u9700\u91cd\u70b9\u8003\u8651\uff09<\/td><\/tr><tr><td><strong>\u70ed\u6c34\u7cfb\u7edf<\/strong><\/td><td>\u5927\u6c34\u91cf+\u6052\u6e29+\u96f6\u51b7\u6c34\uff0c\u63a8\u8350\u201c\u72ec\u7acb\u70ed\u6c34\u5668+\u4e3b\u7ba1\u5faa\u73af\u201d\uff0c\u4e0d\u5efa\u8bae\u4e24\u7528\u7089<\/td><\/tr><tr><td><strong>\u4e8c\u8054\u4f9b\u9009\u578b<\/strong><\/td><td>\u5929\u6c34\u5730\u6c34\uff08\u51fa\u98ce\u67d4\u548c\uff09\u6216\u5929\u6c1f\u5730\u6c34\uff08\u53ef\u8c0318\u2103\u67d4\u98ce+\u9664\u6e7f\uff09\uff0c\u6839\u636e\u5ba2\u6237\u504f\u597d\u63a8\u8350<\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387<\/strong><\/td><td>7\u53f0\u5185\u673a\uff0c\u9700\u5408\u7406\u914d\u7f6e\u5916\u673a\uff0c\u907f\u514d\u5168\u5f00\u6548\u679c\u5dee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f85\u73b0\u573a\u786e\u8ba4\u4e8b\u9879<\/strong><\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>\u4e8c\u697c\u5c42\u9ad8\u662f\u591a\u5c11\uff1f\uff08\u81ea\u5efa\u623f\u901a\u5e383\u7c73\u4ee5\u4e0a\uff09<\/li>\n\n\n\n<li>\u5ba2\u5385\/\u5367\u5ba4\u662f\u5426\u6709\u897f\u6652\uff1f\u662f\u5426\u4e3a\u5927\u9762\u79ef\u843d\u5730\u73bb\u7483\uff1f<\/li>\n\n\n\n<li>\u4e8c\u697c\u662f\u5426\u9700\u8981\u5730\u6696\uff1f\u91c7\u6696\u9762\u79ef\u591a\u5c11\uff1f<\/li>\n\n\n\n<li>\u70ed\u6c34\u9700\u6c42\uff1a\u51e0\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u7528\uff1f\u662f\u5426\u6709\u6d74\u7f38\uff1f<\/li>\n\n\n\n<li>\u5916\u673a\u4f4d\u4f4d\u7f6e\uff1f\uff08\u4e8c\u697c\u662f\u5426\u6709\u5e73\u53f0\uff0c\u8fd8\u662f\u9700\u8981\u4ece\u4e00\u697c\u6216\u697c\u9876\u8d70\u7ba1\uff09<\/li>\n\n\n\n<li>\u71c3\u6c14\u6761\u4ef6\uff1f\uff08\u81ea\u5efa\u623f\u662f\u5426\u6709\u7ba1\u9053\u71c3\u6c14\uff0c\u8fd8\u662f\u9700\u8981\u6db2\u5316\u6c14\uff09<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u521d\u6b65\u5efa\u8bae\u65b9\u5411<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5efa\u8bae<\/th><\/tr><\/thead><tbody><tr><td><strong>\u4e8c\u8054\u4f9b<\/strong><\/td><td>\u63a8\u8350\u5929\u6c1f\u5730\u6c34\uff08\u5c0a\u777f\u5168\u6548\uff09\uff0c\u51fa\u98ce\u53ef\u8c0318\u2103\u67d4\u98ce\uff0c\u8001\u4eba\u5c0f\u5b69\u4e0d\u6015\u5439\uff1b\u4e09\u7ba1\u5236\u72ec\u7acb\u9664\u6e7f\uff0c\u81ea\u5efa\u623f\u6e7f\u5ea6\u95ee\u9898\u4e00\u5e76\u89e3\u51b3<\/td><\/tr><tr><td><strong>\u70ed\u6c34<\/strong><\/td><td>\u72ec\u7acb\u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668\u6216\u5927\u5347\u6570\u71c3\u6c14\u70ed\u6c34\u5668 + \u4e3b\u7ba1\u5faa\u73af\uff0c\u5b9e\u73b0\u5927\u6c34\u91cf\u3001\u6052\u6e29\u3001\u96f6\u51b7\u6c34<\/td><\/tr><tr><td><strong>\u5916\u673a<\/strong><\/td><td>7\u53f0\u5185\u673a\uff0c\u5efa\u8bae220\u4e3b\u673a\uff08\u6216200\uff09\uff0c\u6309\u5b9e\u9645\u51b7\u8d1f\u8377\u7cbe\u786e\u8ba1\u7b97<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h1 class=\"wp-block-heading\">\u5f90\u5148\u751f\u65e5\u7acb\u6c34\u5885\u9002220\u62d68\u53f0\u5185\u673a\u7684\u65b9\u6848<\/h1>\n\n\n\n<h1 class=\"wp-block-heading\">\u9f99\u8109\u6696\u901a \u00b7 \u5f90\u5148\u751f\u81ea\u5efa\u623f\u5929\u6c34\u5730\u6c34220\u62d68\u53f0\u65b9\u6848\u4e66<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u6237<\/strong>\uff1a\u5f90\u5148\u751f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u9879\u76ee\u7c7b\u578b<\/strong>\uff1a\u81ea\u5efa\u623f\uff08\u5c42\u9ad83.3\u7c73\uff0c\u897f\u6652\uff0c\u65e0\u4fdd\u6e29\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u987e\u95ee<\/strong>\uff1a\u90ed\u52c7\u79c0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8054\u7cfb\u7535\u8bdd<\/strong>\uff1a18100839248<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7f16\u5236\u65e5\u671f<\/strong>\uff1a2026\u5e745\u670818\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e00\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u60a8\u8bf4\u7684<\/strong><\/td><td><strong>\u6211\u4eec\u7406\u89e3\u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/strong><\/td><\/tr><tr><td>\u201c\u6548\u679c\u8981\u597d\uff0c\u697c\u4e0a\u9910\u5385\u6548\u679c\u4e0d\u597d\u7684\u7ecf\u5386\u8ba9\u6211\u5f88\u5728\u610f\u201d<\/td><td>\u60a8\u62c5\u5fc3\u7684\u4e0d\u662f\u54c1\u724c\uff0c\u662f\u5b89\u88c5\u5de5\u827a\u2014\u2014\u7ba1\u8def\u8bbe\u8ba1\u3001\u6d41\u91cf\u5206\u914d<\/td><\/tr><tr><td>\u201c\u5c3d\u91cf\u914d\u5927\u70b9\uff0c\u5bb6\u4eba\u6015\u70ed\uff0c\u665a\u4e0a\u51e0\u4e2a\u5367\u5ba4\u540c\u65f6\u5f00\u201d<\/td><td>\u6700\u70ed\u5929\u51b7\u5f97\u4e0b\u6765\u3001\u5168\u5f00\u4e0d\u62a2\u98ce\u91cf<\/td><\/tr><tr><td>\u201c\u5916\u673a\u57284\u697c\uff0c\u65e0\u7535\u68af\u201d<\/td><td>\u642c\u8fd0\u4e0d\u7834\u574f\u88c5\u4fee\uff0c\u5916\u673a\u4f4d\u7f8e\u5316<\/td><\/tr><tr><td>\u201c\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff0c\u5bb6\u91cc\u4eba\u591a\u201d<\/td><td>\u4e24\u4e2a\u536b\u751f\u95f4\u540c\u65f6\u6d17\u6fa1\u6c34\u6e29\u4e0d\u6ce2\u52a8<\/td><\/tr><tr><td>\u201c\u5c42\u9ad83.3\u7c73\uff0c\u62c5\u5fc3\u6548\u679c\u201d<\/td><td>\u6c14\u6d41\u7ec4\u7ec7\u6bd4\u529f\u7387\u66f4\u91cd\u8981<\/td><\/tr><tr><td>\u201c\u897f\u6652\uff0c\u672a\u505a\u4fdd\u6e29\u201d<\/td><td>\u6309\u9ad8\u6807\u51c6\u914d\u7f6e\uff0c\u4e0b\u5348\u591f\u51b7<\/td><\/tr><tr><td>\u201c\u697c\u4e0a\u6696\u6c14\u7247\u6708\u8d391500-2000\u5143\uff0c\u89c9\u5f97\u9ad8\u201d<\/td><td>\u7a7a\u6c14\u80fd\u5730\u6696\u6bd4\u71c3\u6c14\u770140%<\/td><\/tr><tr><td>\u201c\u5206\u5ba4\u63a7\u6e29\u201d<\/td><td>\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acb\u63a7\u6e29\uff0c\u624b\u673a\u8fdc\u7a0b\u64cd\u4f5c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e8c\u3001\u6700\u7ec8\u65b9\u6848\uff1a\u5929\u6c34\u5730\u6c34\uff08\u6c34\u5885\u9002\uff09\u4e00\u62d6\u516b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a8\u5df2\u660e\u786e\u9009\u62e9<strong>\u65e5\u7acb\u6c34\u5885\u9002\u00b7\u5929\u6c34\u5730\u6c34<\/strong>\uff0c\u7a7a\u8c03\u51fa\u98ce\u67d4\u548c\u3001\u5730\u6696\u8282\u80fd\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5ba4\u5916\u4e3b\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u7cfb\u5217<\/strong><\/td><td><strong>\u578b\u53f7<\/strong><\/td><td><strong>\u5236\u51b7\u91cf<\/strong><\/td><td><strong>\u8fd0\u884c\u8303\u56f4<\/strong><\/td><td><strong>\u7535\u6e90<\/strong><\/td><\/tr><tr><td>\u65e5\u7acb\u6c34\u5885\u9002FX<\/td><td>RAS-220FPUEN2Q\/M<\/td><td>20.0 kW<\/td><td>-25\u2103~45\u2103<\/td><td>380V\u4e09\u76f8\u7535<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u5ba4\u5185\u673a\u914d\u7f6e\uff088\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u533a\u57df<\/strong><\/td><td><strong>\u9762\u79ef<\/strong><\/td><td><strong>\u578b\u53f7<\/strong><\/td><td><strong>\u5236\u51b7\u91cf<\/strong><\/td><td><strong>\u6570\u91cf<\/strong><\/td><\/tr><tr><td>\u5ba2\u5385A<\/td><td>51\u33a1<\/td><td>RFP-102WAR\/DBT\/P<\/td><td>6.4kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u5ba2\u5385B<\/td><td>\u540c\u533a<\/td><td>RFP-102WAR\/DBT\/P<\/td><td>6.4kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u9910\u5385<\/td><td>16.5\u33a1<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>4.3kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u4e3b\u5367<\/td><td>19\u33a1<\/td><td>RFP-85WAR\/DBT\/P<\/td><td>5.7kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u6b21\u53671<\/td><td>11.5\u33a1<\/td><td>RFP-51WAR\/DBT\/P<\/td><td>3.45kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u6b21\u53672<\/td><td>11.5\u33a1<\/td><td>RFP-51WAR\/DBT\/P<\/td><td>3.45kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u5957\u623f-\u5367\u5ba4<\/td><td>16\u33a1<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>4.3kW<\/td><td>1\u53f0<\/td><\/tr><tr><td>\u5957\u623f-\u8863\u5e3d\u95f4<\/td><td>12\u33a1<\/td><td>RFP-51WAR\/DBT\/P<\/td><td>3.45kW<\/td><td>1\u53f0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5408\u8ba1<\/strong>\uff1a8\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\uff0c\u603b\u5236\u51b7\u91cf&nbsp;<strong>36.65 kW\u8d85\u914d\u7387<\/strong>\uff1a36.65 \u00f7 20.0 =&nbsp;<strong>183%<\/strong>\uff08\u6c34\u7cfb\u7edf\u5141\u8bb8\u2264200%\uff0c\u914d\u7f6e\u5408\u7406\u2705\uff09<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5730\u6696\u7cfb\u7edf<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u9879\u76ee<\/strong><\/td><td><strong>\u53c2\u6570<\/strong><\/td><\/tr><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>136.5\u33a1<\/td><\/tr><tr><td>\u70ed\u6e90<\/td><td>\u6c34\u5885\u9002\u4e3b\u673a\uff08\u7a7a\u6c14\u80fd\u70ed\u6cf5\uff09<\/td><\/tr><tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>35-45\u2103\uff08\u6bd4\u71c3\u6c14\u770140%+\uff09<\/td><\/tr><tr><td>\u76d8\u7ba1\u89c4\u683c<\/td><td>\u4f1f\u661fPE-RT\u7ba1 De20<\/td><\/tr><tr><td>\u4e3b\u7ba1\u89c4\u683c<\/td><td>\u4f1f\u661fF-PPR De32<\/td><\/tr><tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u66fc\u745e\u5fb7WiFi\u5ba4\u6e29\u8054\u52a8\uff08\u5206\u533a\u63a7\u6e29+\u4e3b\u673a\u8054\u52a8\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e09\u3001\u6700\u7ec8\u4f18\u60e0\u62a5\u4ef7<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u9879\u76ee<\/strong><\/td><td><strong>\u91d1\u989d<\/strong><\/td><\/tr><tr><td>\u539f\u4ef7\uff08\u7a7a\u8c03+\u5730\u6696\uff09<\/td><td>118,745\u5143<\/td><\/tr><tr><td>\u51cf\uff1a\u6bcf\u53f0\u8bbe\u5907\u4f18\u60e0\uff089\u53f0\u00d71000\u5143\uff09<\/td><td>-9,000\u5143<\/td><\/tr><tr><td>\u51cf\uff1a\u56fd\u8865<\/td><td>-1,500\u5143<\/td><\/tr><tr><td>\u51cf\uff1a\u5382\u5bb6\u4f18\u60e0<\/td><td>-1,000\u5143<\/td><\/tr><tr><td>\u51cf\uff1a5\u5e74\u4f1a\u5458\u8d39\uff08\u6696\u901a\u91d1\u989d\u62b5\u6263\uff09<\/td><td>-1,000\u5143<\/td><\/tr><tr><td><strong>\u6700\u7ec8\u5230\u624b\u603b\u4ef7<\/strong><\/td><td><strong>106,245\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8d60\u9001<\/strong>\uff1a13\u5347\u6052\u6e29\u70ed\u6c34\u56681\u53f0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u56db\u3001\u539f\u65b9\u6848\u4e0e\u65b0\u65b9\u6848\u5bf9\u6bd4<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u5bf9\u6bd4\u9879<\/strong><\/td><td><strong>\u539f\u65b9\u6848\uff087\u53f0\uff09<\/strong><\/td><td><strong>\u65b0\u65b9\u6848\uff088\u53f0\uff09<\/strong><\/td><\/tr><tr><td>\u5185\u673a\u914d\u7f6e<\/td><td>85\u578b\u00d73 + 68\u578b\u00d71 + 34\u578b\u00d72<\/td><td>102\u578b\u00d72 + 85\u578b\u00d71 + 68\u578b\u00d71 + 51\u578b\u00d74<\/td><\/tr><tr><td>\u5185\u673a\u6570\u91cf<\/td><td>7\u53f0<\/td><td>8\u53f0<\/td><\/tr><tr><td>\u603b\u51b7\u91cf<\/td><td>35.7 kW<\/td><td>36.65 kW<\/td><\/tr><tr><td>\u8d85\u914d\u7387<\/td><td>178.5%<\/td><td>183%<\/td><\/tr><tr><td>\u6700\u7ec8\u603b\u4ef7<\/td><td>99,842\u5143<\/td><td><strong>106,245\u5143<\/strong><\/td><\/tr><tr><td>\u5dee\u4ef7<\/td><td>\u2014<\/td><td>+6,403\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e94\u3001\u65b9\u6848\u6838\u5fc3\u4f18\u52bf<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u7279\u70b9<\/strong><\/td><td><strong>\u8bf4\u660e<\/strong><\/td><\/tr><tr><td><strong>\u51fa\u98ce\u67d4\u548c<\/strong><\/td><td>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\uff0c\u65e0\u5439\u98ce\u611f<\/td><\/tr><tr><td><strong>\u5730\u6696\u8282\u80fd<\/strong><\/td><td>\u7a7a\u6c14\u80fd\u6bd4\u71c3\u6c14\u770140%+\uff0c\u957f\u671f\u7701\u6c14\u8d39<\/td><\/tr><tr><td><strong>\u8d85\u914d\u7387\u5408\u7406<\/strong><\/td><td>166.6%\u5168\u5f00\u4e0d\u62a2\u98ce\u91cf<\/td><\/tr><tr><td><strong>\u5206\u5ba4\u63a7\u6e29<\/strong><\/td><td>WiFi\u7ebf\u63a7\u5668\uff0c\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acb\u63a7\u6e29<\/td><\/tr><tr><td><strong>\u4ef7\u683c\u900f\u660e<\/strong><\/td><td>\u6bcf\u53f0\u8bbe\u5907\u4f18\u60e01000\u5143\uff0c\u4f18\u60e0\u660e\u7ec6\u6e05\u6670<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u516d\u3001\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u627f\u8bfa\u9879<\/strong><\/td><td><strong>\u5185\u5bb9<\/strong><\/td><\/tr><tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/td><\/tr><tr><td>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><\/tr><tr><td>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e03\u3001\u4f1a\u5458\u6743\u76ca\uff085\u5e74\u4f1a\u5458\uff09<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u6743\u76ca<\/strong><\/td><td><strong>\u5185\u5bb9<\/strong><\/td><\/tr><tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td>\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u670d\u52a1\u6298\u6263<\/td><td>5-8\u6298<\/td><\/tr><tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/td><\/tr><tr><td>\u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8<\/td><td>\u4e0d\u9650\u6b21\u6570<\/td><\/tr><tr><td>\u7ef4\u4fdd\u63d0\u9192<\/td><td>\u6ee4\u82af\u66f4\u6362\u3001\u6e05\u6d17\u4e3b\u52a8\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6700\u7ec8\u603b\u4ef7\uff1a106,245\u5143<\/strong><\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2-1024x768.jpg\" alt=\"\" class=\"wp-image-1933\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/9e231d53328bab27d3aa9812fcf6dfd1-2-1024x768.jpg\" alt=\"\" class=\"wp-image-1934\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/9e231d53328bab27d3aa9812fcf6dfd1-2-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/9e231d53328bab27d3aa9812fcf6dfd1-2-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/9e231d53328bab27d3aa9812fcf6dfd1-2-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/9e231d53328bab27d3aa9812fcf6dfd1-2-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/9e231d53328bab27d3aa9812fcf6dfd1-2.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/7081750b4b1d54919b7bcdc31112ff55-1-1024x768.jpg\" alt=\"\" class=\"wp-image-1935\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/7081750b4b1d54919b7bcdc31112ff55-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/7081750b4b1d54919b7bcdc31112ff55-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/7081750b4b1d54919b7bcdc31112ff55-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/7081750b4b1d54919b7bcdc31112ff55-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/7081750b4b1d54919b7bcdc31112ff55-1.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/2b2ff0eff28db1a0a978dd5790f3d6b9-2-1024x768.jpg\" alt=\"\" class=\"wp-image-1936\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/2b2ff0eff28db1a0a978dd5790f3d6b9-2-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/2b2ff0eff28db1a0a978dd5790f3d6b9-2-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/2b2ff0eff28db1a0a978dd5790f3d6b9-2-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/2b2ff0eff28db1a0a978dd5790f3d6b9-2-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/2b2ff0eff28db1a0a978dd5790f3d6b9-2.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-3-1024x768.jpg\" alt=\"\" class=\"wp-image-1937\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-3-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-3-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-3-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-3-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-3.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/676cb6763470412e3ea53d8afa4ab634-1-1024x768.jpg\" alt=\"\" class=\"wp-image-1938\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/676cb6763470412e3ea53d8afa4ab634-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/676cb6763470412e3ea53d8afa4ab634-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/676cb6763470412e3ea53d8afa4ab634-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/676cb6763470412e3ea53d8afa4ab634-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/676cb6763470412e3ea53d8afa4ab634-1.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/73a2ca6c6b876f4b4ba93fa0503dc629-1-1024x768.jpg\" alt=\"\" class=\"wp-image-1939\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/73a2ca6c6b876f4b4ba93fa0503dc629-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/73a2ca6c6b876f4b4ba93fa0503dc629-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/73a2ca6c6b876f4b4ba93fa0503dc629-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/73a2ca6c6b876f4b4ba93fa0503dc629-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/73a2ca6c6b876f4b4ba93fa0503dc629-1.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/c606558dfdb727201444dba6fd2707e6-1-1024x768.jpg\" alt=\"\" class=\"wp-image-1940\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/c606558dfdb727201444dba6fd2707e6-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/c606558dfdb727201444dba6fd2707e6-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/c606558dfdb727201444dba6fd2707e6-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/c606558dfdb727201444dba6fd2707e6-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/c606558dfdb727201444dba6fd2707e6-1.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/09e2dd2785e25ebb2846f91013e25916-1-1024x768.jpg\" alt=\"\" class=\"wp-image-1941\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/09e2dd2785e25ebb2846f91013e25916-1-1024x768.jpg 1024w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/09e2dd2785e25ebb2846f91013e25916-1-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/09e2dd2785e25ebb2846f91013e25916-1-768x576.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/09e2dd2785e25ebb2846f91013e25916-1-1536x1152.jpg 1536w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/09e2dd2785e25ebb2846f91013e25916-1.jpg 1707w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u73b0\u573a\u5b9a\u4f4d<\/li>\n\n\n\n<li><\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23-576x1024.jpg\" alt=\"\" class=\"wp-image-1987\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23-768x1366.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23-1152x2048.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/0fb97805cae45a4d992760b137966c23.jpg 1280w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0-576x1024.jpg\" alt=\"\" class=\"wp-image-1988\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0-768x1366.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0-1152x2048.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/23f3ec8137c7c1b8871e40b2447157a0.jpg 1280w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195-576x1024.jpg\" alt=\"\" class=\"wp-image-1989\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195-576x1024.jpg 576w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195-169x300.jpg 169w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195-768x1366.jpg 768w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195-864x1536.jpg 864w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195-1152x2048.jpg 1152w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/d7c2db9c3025982b3b6d58ce6da3a195.jpg 1280w\" sizes=\"auto, (max-width: 576px) 100vw, 576px\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u57fa\u672c\u4fe1\u606f \u5b57\u6bb5 \u5185\u5bb9 \u5ba2\u6237\u59d3\u540d \u5f90\u5148\u751f  [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1919","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u81ea\u5efa\u623f\u4e8c\u8054\u4f9b\u51b7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u89e3\u51b3\u65b9\u6848\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1919\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u81ea\u5efa\u623f\u4e8c\u8054\u4f9b\u51b7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u89e3\u51b3\u65b9\u6848\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1919\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-02T02:54:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1707\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919\",\"name\":\"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/34a5b2496a5b1aceb512f35446269761-2-1024x768.jpg\",\"datePublished\":\"2026-05-31T03:40:10+00:00\",\"dateModified\":\"2026-06-02T02:54:55+00:00\",\"description\":\"\u81ea\u5efa\u623f\u4e8c\u8054\u4f9b\u51b7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u89e3\u51b3\u65b9\u6848\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/34a5b2496a5b1aceb512f35446269761-2.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/34a5b2496a5b1aceb512f35446269761-2.jpg\",\"width\":1707,\"height\":1280},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1919#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34 - \u9f99\u8109\u6696\u901a","description":"\u81ea\u5efa\u623f\u4e8c\u8054\u4f9b\u51b7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u89e3\u51b3\u65b9\u6848","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1919","og_locale":"zh_CN","og_type":"article","og_title":"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34 - \u9f99\u8109\u6696\u901a","og_description":"\u81ea\u5efa\u623f\u4e8c\u8054\u4f9b\u51b7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u89e3\u51b3\u65b9\u6848","og_url":"https:\/\/longmai-nt.com\/?page_id=1919","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-02T02:54:55+00:00","og_image":[{"width":1707,"height":1280,"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1919","url":"https:\/\/longmai-nt.com\/?page_id=1919","name":"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=1919#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=1919#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2-1024x768.jpg","datePublished":"2026-05-31T03:40:10+00:00","dateModified":"2026-06-02T02:54:55+00:00","description":"\u81ea\u5efa\u623f\u4e8c\u8054\u4f9b\u51b7\u6696\u548c\u751f\u6d3b\u70ed\u6c34\u89e3\u51b3\u65b9\u6848","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1919#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1919"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=1919#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/05\/34a5b2496a5b1aceb512f35446269761-2.jpg","width":1707,"height":1280},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1919#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5929\u5e9c\u65b0\u533a\u5927\u6797\u9547\u5f90\u5148\u751f\u4e8c\u8054\u4f9b\u52a0\u70ed\u6c34"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1919","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1919"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1919\/revisions"}],"predecessor-version":[{"id":1990,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1919\/revisions\/1990"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1919"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}