{"id":1957,"date":"2026-05-31T19:58:40","date_gmt":"2026-05-31T11:58:40","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1957"},"modified":"2026-10-28T18:03:26","modified_gmt":"2026-10-28T10:03:26","slug":"%e6%97%a5%e7%ab%8b%e6%99%ba%e4%ba%ab%e5%a4%a9%e6%b0%9f%e5%9c%b0%e6%b0%b4%e4%b8%80%e4%bd%93%e5%bc%8f%e4%b8%a4%e8%81%94%e4%be%9b-%c2%b7-%e5%85%a8%e7%bb%b4%e8%af%a6%e6%83%85%e9%a1%b5","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1957","title":{"rendered":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u5148\u7ed9\u7ed3\u8bba\uff1a\u8fd9\u4e00\u9875\u53ea\u8bb2\u667a\u4eab\u8fd9\u4e00\u53f0\u673a\u5668<\/h2>\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acb\u62ff\u6c1f\u7cfb\u7edf\u4e3b\u673a\u505a\u5730\u6696\uff0c\u4e00\u5171\u6709\u56db\u6761\u8def\u3002\u8fd9\u4e00\u9875\u53ea\u8d70\u5176\u4e2d\u4e00\u6761\u2014\u2014<strong>\u667a\u4eab\u5929\u6c1f\u5730\u6c34<\/strong>\uff0c\u5b83\u81ea\u5df1\u53c8\u5206 AQ \u548c NQ \u4e24\u4e2a\u7cfb\u5217\uff1aAQ \u80fd\u51fa\u751f\u6d3b\u70ed\u6c34\uff0c\u4f46\u70ed\u6c34\u548c\u5730\u6696\u4e8c\u9009\u4e00\uff1bNQ \u53ea\u505a\u51b7\u6696\uff0c\u6c34\u6cf5\u548c\u6c34\u6e29\u5168\u81ea\u52a8\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u8fd8\u6ca1\u5b9a\u8d70\u667a\u4eab\u3001\u5168\u6548\u2161 \u8fd8\u662f\u522b\u5885\u7684\uff0c\u5148\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\u3002<\/strong>\u786e\u5b9a\u8d70\u667a\u4eab\u4e86\uff0c\u518d\u56de\u6765\u770b\u8fd9\u4e00\u9875\u2014\u2014\u4e0b\u9762\u7684\u53c2\u6570\u3001\u5b89\u88c5\u3001\u4ef7\u683c\u3001\u6545\u969c\u6392\u67e5\uff0c\u5168\u662f\u8fd9\u4e00\u53f0\u673a\u5668\u7684\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u4e0b\u9762\u662f\u76ee\u5f55\uff0c\u60f3\u76f4\u63a5\u770b\u54ea\u4e00\u8282\uff0c\u70b9\u8fc7\u53bb\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ae0\u8282<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u524d\u8a00<\/td><td><a href=\"#rlzxqy\">\u4e00\u90e8\u51b7\u6696\u7f16\u5e74\u53f2\uff08\u767e\u5e74\u65f6\u95f4\u7ebf+\u667a\u4eab\u53d1\u5c55\u4e3b\u7ebf\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u4e00\u7ae0<\/td><td><a href=\"#rlzx01\">\u75db\u70b9\u5f15\u5165\u2014\u2014\u4e2d\u56fd\u5bb6\u5ead\u7684\u51b7\u6696\u56f0\u5c40\uff08\u4e09\u96be\u56f0\u5883\u3001\u5357\u65b9\u75db\u70b9\u300115\u5e74\u6210\u672c\u5bf9\u6bd4\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u4e8c\u7ae0<\/td><td><a href=\"#rlzx02\">\u6280\u672f\u89e3\u6790\u2014\u2014\u5929\u6c1f\u5730\u6c34\u7684\u6839\u6280\u672f\uff08\u884c\u4e1a\u7b80\u53f2\u3001\u6280\u672f\u539f\u7406\u3001AQ\/NQ\u5168\u7cfb\u5217\u53c2\u6570\u8868\u3001\u6838\u5fc3\u7ec4\u4ef6\u3001\u56db\u4f4d\u4e00\u4f53\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u4e09\u7ae0<\/td><td><a href=\"#rlzx03\">\u7834\u9664\u8bef\u533a\u2014\u2014\u5929\u6c1f\u5730\u6c34\u8ba4\u77e5\u7ea0\u504f\uff08\u6c1f\u7cfb\u7edf\u5065\u5eb7\u3001\u8212\u9002\u5ea6\u3001\u51ac\u5b63\u5236\u70ed\u3001\u4e00\u4f53\u673a\u7ef4\u4fee\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u56db\u7ae0<\/td><td><a href=\"#rlzx04\">\u4ea7\u54c1\u77e9\u9635\u2014\u2014\u667a\u4eab\u5168\u7cfb\u8be6\u89e3\uff08AQ vs NQ\u5bf9\u6bd4\u3001\u4e0d\u53e6\u914d\u6c34\u6a21\u5757\u3001\u5ba4\u5185\u673a\u77e9\u9635\u3001\u4e94\u6052\u5347\u7ea7\u8def\u5f84\u3001\u5168\u5c4b\u5168\u611f2.0\/3.0\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u4e94\u7ae0<\/td><td><a href=\"#rlzx05\">\u9884\u7b97\u4e0e\u901f\u67e5\uff08\u9884\u7b97\u53c2\u8003\u3001\u9009\u578b\u53e3\u8bc0\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u516d\u7ae0<\/td><td><a href=\"#rlzx06\">\u7ade\u54c1\u5b9a\u4f4d\u2014\u2014\u667a\u4eab\u548c\u6c34\u5885\u9002\u600e\u4e48\u5206\uff08\u6df1\u5ea6\u5bf9\u6bd4\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u4e03\u7ae0<\/td><td><a href=\"#rlzx07\">\u5929\u6c1f\u5730\u6c34 vs \u71c3\u6c14\u58c1\u6302\u7089\u2014\u2014\u5168\u7ef4\u5ea6\u5bf9\u6bd4\uff08\u516d\u7ef4\u5ea6\u5bf9\u6bd4\u300120\u5e74\u6210\u672c\u5206\u6790\u3001\u6295\u8d44\u56de\u6536\u671f\u3001\u5e38\u89c1\u7591\u8651\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u516b\u7ae0<\/td><td><a href=\"#rlzx08\">\u5b89\u88c5\u89c4\u8303\u2014\u2014\u6807\u51c6\u5316\u65bd\u5de5\u5168\u6d41\u7a0b\uff08\u5b89\u88c5\u51c6\u5907\u3001\u5de5\u827a\u6d41\u7a0b\u3001\u9a8c\u6536\u6807\u51c6\u3001\u8bbe\u8ba1\u89c4\u8303\u3001\u7cbe\u5de56\u6b65\u6cd5+2\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u4e5d\u7ae0<\/td><td><a href=\"#rlzx09\">\u771f\u5b9e\u6848\u4f8b\u2014\u2014\u5168\u56fd\u5178\u578b\u7528\u6237\u5b9e\u88c5\u53cd\u9988\uff08\u6210\u90fd\/\u676d\u5dde\/\u5317\u4eac\/\u5e7f\u5dde\u56db\u6848\u4f8b\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u5341\u7ae0<\/td><td><a href=\"#rlzx10\">\u4f7f\u7528\u7ef4\u62a4\u2014\u2014\u5168\u751f\u547d\u5468\u671f\u624b\u518c\uff08\u65e5\u5e38\u4f7f\u7528\u3001\u5b63\u8282\u5207\u6362\u3001\u5ef6\u957f\u5bff\u547d\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u5341\u4e00\u7ae0<\/td><td><a href=\"#rlzx11\">\u6545\u969c\u6392\u67e5\u2014\u2014\u901f\u67e5\u4e0e\u89e3\u51b3\u65b9\u6848\uff08\u5e38\u89c1\u95ee\u9898\u3001\u6545\u969c\u4ee3\u7801\u3001\u62a5\u4fee\u6d41\u7a0b\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u5341\u4e8c\u7ae0<\/td><td><a href=\"#rlzx12\">FAQ\u2014\u2014\u9009\u578b\u4e0e\u4f7f\u7528\u5e38\u89c1\u95ee\u9898\uff08\u9009\u578b\u7c7b\u3001\u4f7f\u7528\u7c7b\u3001\u6280\u672f\u7c7b\uff09<\/a><\/td><\/tr><tr><td>\u7b2c\u5341\u4e09\u7ae0<\/td><td><a href=\"#rlzx13\">\u4ea7\u54c1\u8fed\u4ee3\u65e5\u5fd7<\/a><\/td><\/tr><tr><td>\u9644\u5f55A<\/td><td><a href=\"#rlzxfla\">\u672f\u8bed\u901f\u67e5\u8868<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzxqy\" class=\"wp-block-heading\">\u524d\u8a00\uff1a\u4e00\u90e8\u51b7\u6696\u7f16\u5e74\u53f2<\/h2>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u53d9\u4e8b\u4e3b\u7ebf<\/strong>\uff1a\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u7684\u53d1\u5c55\u5386\u7a0b<br><strong>\u5bf9\u7167\u526f\u7ebf<\/strong>\uff1a\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u767e\u5e74\u6280\u672f\u79ef\u6dc0<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u767e\u5e74\u65f6\u95f4\u7ebf\uff08\u526f\u7ebf\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65f6\u95f4\u8282\u70b9<\/th><th>\u5173\u952e\u4e8b\u4ef6<\/th><th>\u884c\u4e1a\u610f\u4e49<\/th><\/tr><\/thead><tbody><tr><td>1910\u5e74<\/td><td>\u65e5\u7acb\u96c6\u56e2\u6210\u7acb\uff0c\u6d89\u8db3\u7535\u673a\u4e0e\u538b\u7f29\u673a\u5236\u9020<\/td><td>\u52a8\u529b\u6280\u672f\u57fa\u56e0\u81ea\u6b64\u690d\u5165<\/td><\/tr><tr><td>1932\u5e74<\/td><td>\u81ea\u4e3b\u7814\u53d1\u7b2c\u4e00\u53f0\u67dc\u5f0f\u7a7a\u8c03<\/td><td>\u8fdb\u5165\u7a7a\u8c03\u5236\u9020\u9886\u57df<\/td><\/tr><tr><td>1983\u5e74<\/td><td>\u7814\u53d1\u51fa\u4e16\u754c\u7b2c\u4e00\u53f0\u6da1\u65cb\u5f0f\u7a7a\u8c03\u538b\u7f29\u673a<\/td><td>\u5960\u5b9a\u53d8\u9891\u7a7a\u8c03\u6280\u672f\u57fa\u77f3<\/td><\/tr><tr><td>1993\u5e74<\/td><td>\u8fdb\u5165\u4e2d\u56fd\u5e02\u573a\uff0c\u6df1\u5733\u8bbe\u5382<\/td><td>\u56fd\u4ea7\u5316\u5bb6\u7528\u4e2d\u592e\u7a7a\u8c03\u8d77\u6b65<\/td><\/tr><tr><td>2003\u5e74<\/td><td>\u63a8\u51fa\u7b2c\u4e00\u4ee3\u53d8\u9891\u591a\u8054\u673a\uff0cIPLV\u8fbe4.5<\/td><td>\u9886\u5148\u884c\u4e1a\u80fd\u6548\u6c34\u5e73<\/td><\/tr><tr><td>2010\u5e74<\/td><td>\u63a8\u51fa\"VAM\u5c0a\u777f\"\u7cfb\u5217\uff0c\u642d\u8f7d\u5168\u53d8\u9891\u6280\u672f<\/td><td>\u9ad8\u7aef\u4f4f\u5b85\u9996\u9009\u4ea7\u54c1\u786e\u7acb<\/td><\/tr><tr><td>2015\u5e74<\/td><td>\u63a8\u51fa\"\u5f3a\u70edD\"\u7cfb\u5217\uff0c\u9996\u6b21\u52a0\u6c34\u6a21\u5757<\/td><td>\u6b63\u5f0f\u8fdb\u5165\u4e24\u8054\u4f9b\u9886\u57df<\/td><\/tr><tr><td>2017\u5e74<\/td><td>\u7814\u53d1\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u6280\u672f<\/td><td>\u5f00\u521b\u5168\u65b0\u6280\u672f\u8def\u7ebf<\/td><\/tr><tr><td>2018\u5e74<\/td><td>\u521d\u4ee3\u667a\u4eab\u7cfb\u5217\u53d1\u5e03\uff0c\u6c34\u6a21\u5757\u642c\u8fdb\u5916\u673a<\/td><td>\"\u6574\u4f53\u5f0f\u5929\u6c1f\u5730\u6c34\"\u4e00\u4f53\u673a\u8bde\u751f<\/td><\/tr><tr><td>2020\u5e74<\/td><td>\u7b2c\u4e8c\u4ee3\u667a\u4eab\uff0c\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u4e00\u4f53\u5316<\/td><td>\u5b89\u88c5\u6548\u7387\u63d0\u534750%<\/td><\/tr><tr><td>2022\u5e74<\/td><td>\u63a5\u5165\"\u667a\u4eab\u5bb6\"IoT\u5e73\u53f0\uff0c\u63a8\u51fa-25\u2103\u578b\u53f7<\/td><td>\u667a\u80fd\u8054\u52a8+\u5317\u65b9\u91c7\u6696\u5168\u8986\u76d6<\/td><\/tr><tr><td>2023\u5e74<\/td><td>\u7b2c\u4e09\u4ee3\u667a\u4eab\u4e0a\u5e02\uff1b\"\u5168\u5c4b\u5168\u611f2.0\"\u53d1\u5e03<\/td><td>\u5929\u6c1f\u5730\u6c34\u4ee3\u8868\u878d\u5165\u4e94\u6052\u7cfb\u7edf<\/td><\/tr><tr><td>2024\u5e74<\/td><td>\u63a8\u51fa\u5c0f\u578b\u5316\u578b\u53f7\uff0c\u9002\u914d90-120\u33a1\u5c0f\u6237\u578b<\/td><td>\u5e02\u573a\u8986\u76d6\u5411\u4e0b\u5ef6\u4f38<\/td><\/tr><tr><td>2025\u5e74<\/td><td>\"\u5168\u5c4b\u5168\u611f3.0\"\u53d1\u5e03\uff0c\u63a5\u5165AI\u667a\u63a7<\/td><td>\u667a\u80fd\u5316\u518d\u5347\u7ea7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u53d1\u5c55\u4e3b\u7ebf<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acb\u667a\u4eab\u7cfb\u5217\u7684\u8bde\u751f\uff0c\u6e90\u4e8e\u4e00\u4e2a\u6734\u7d20\u4f46\u6df1\u523b\u7684\u884c\u4e1a\u6d1e\u5bdf\uff1a<strong>\u4e2d\u56fd\u5bb6\u5ead\u9700\u8981\u4e00\u5957\u7cfb\u7edf\u540c\u65f6\u89e3\u51b3\u5236\u51b7\u548c\u91c7\u6696\uff0c\u4f46\u4f20\u7edf\u65b9\u6848\u603b\u5728\u67d0\u4e00\u7aef\u59a5\u534f\u3002<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>2015\u5e74<\/strong>\uff1a\u65e5\u7acb\u4ee5\"\u5f3a\u70edD\"\u7cfb\u5217\u8bd5\u6c34\u4e24\u8054\u4f9b\uff0c\u5916\u6302\u6c34\u6a21\u5757\u5b9e\u73b0\"\u6c1f\u673a\u5236\u51b7+\u6c34\u7cfb\u7edf\u91c7\u6696\"\uff0c\u8fc8\u51fa\u7b2c\u4e00\u6b65\u3002<\/li>\n\n\n\n<li><strong>2018\u5e74<\/strong>\uff1a\u521d\u4ee3\u667a\u4eab\uff08SET-FREE\uff09\u53d1\u5e03\u3002\u6838\u5fc3\u7a81\u7834\u662f\u5c06\u6c34\u6a21\u5757\u4ece\"\u5916\u6302\"\u53d8\u4e3a\"\u5185\u7f6e\"\uff0c\u5b9e\u73b0\u6574\u4f53\u5f0f\u5929\u6c1f\u5730\u6c34\u4e00\u4f53\u673a\u3002SET-FREE \u4e09\u4e2a\u8bcd\u5b9a\u4e49\u4e86\u4ea7\u54c1\u54f2\u5b66\u2014\u2014<strong>\u5b89\u88c5\u81ea\u7531\u3001\u8bbe\u8ba1\u81ea\u7531\u3001\u7a7a\u95f4\u81ea\u7531<\/strong>\u3002<\/li>\n\n\n\n<li><strong>2020\u5e74<\/strong>\uff1a\u7b2c\u4e8c\u4ee3\u5347\u7ea7\uff0c\u642d\u8f7d\u5929\u6c1f\u5730\u6c34\u4e13\u7528\u538b\u7f29\u673a\uff0c-15\u2103\u5236\u70edCOP\u8fbe2.8\uff0c\u540c\u65f6\u4e3b\u673a\u4e0e\u6c34\u6a21\u5757\u7269\u7406\u4e00\u4f53\u5316\uff0c\u5b89\u88c5\u7a7a\u95f4\u51cf\u5c1130%\u3002<\/li>\n\n\n\n<li><strong>2023\u5e74<\/strong>\uff1a\u7b2c\u4e09\u4ee3\u642d\u8f7d\u5168\u53d8\u9891+\u667a\u80fd\u9664\u971c\u7b97\u6cd5+5G\u7269\u8054\uff0c\u63a5\u5165\"\u5168\u5c4b\u5168\u611f2.0\"\u4e94\u6052\u7cfb\u7edf\uff0c\u6210\u4e3a\"\u6c1f\u673a\u4e94\u6052\"\u7684\u6807\u6746\u8f7d\u4f53\u3002<\/li>\n\n\n\n<li><strong>2025\u5e74<\/strong>\uff1a\u63a5\u5165\"\u5168\u5c4b\u5168\u611f3.0\"AI\u667a\u63a7\uff0c\u7cfb\u7edf\u53ef\u81ea\u4e3b\u5b66\u4e60\u7528\u6237\u4e60\u60ef\uff0c\u81ea\u52a8\u4f18\u5316\u8fd0\u884c\u7b56\u7565\u3002<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u667a\u4eab<\/strong>\u4e8c\u5b57\u91ca\u4e49\uff1a<strong>\u667a<\/strong>\u80fd\u8212\u9002\uff0c\u81ea<strong>\u4eab<\/strong>\u53d7\u3002\u4e00\u5957\u7cfb\u7edf\uff0c\u51b7\u6696\u81ea\u77e5\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx01\" class=\"wp-block-heading\">\u7b2c\u4e00\u7ae0\uff1a\u75db\u70b9\u5f15\u5165\u2014\u2014\u4e2d\u56fd\u5bb6\u5ead\u7684\u51b7\u6696\u56f0\u5c40<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1.1 \u4f20\u7edf\u65b9\u6848\u7684\"\u4e09\u96be\u56f0\u5883\"<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e2d\u56fd\u5bb6\u5ead\u5728\u51b7\u6696\u65b9\u6848\u4e0a\u9762\u4e34\u4e00\u4e2a\u7ecf\u5178\u7684\u4e09\u96be\u9009\u62e9\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65b9\u6848<\/th><th>\u5236\u51b7\u6548\u679c<\/th><th>\u91c7\u6696\u6548\u679c<\/th><th>\u5b89\u88c5\u590d\u6742\u5ea6<\/th><th>\u8fd0\u884c\u8d39\u7528<\/th><th>\u7efc\u5408\u8bc4\u4ef7<\/th><\/tr><\/thead><tbody><tr><td>\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03 + \u71c3\u6c14\u58c1\u6302\u7089\u5730\u6696<\/td><td>\u2605\u2605\u2605\u2605 \u5feb\u51b7<\/td><td>\u2605\u2605\u2605 \u5e72\u71e5\/\u8d39\u7528\u9ad8<\/td><td>\u2605\u2605 \u4e24\u5957\u7cfb\u7edf<\/td><td>\u2605 \u71c3\u6c14\u8d39\u9ad8<\/td><td>\u5236\u51b7\u597d\u3001\u91c7\u6696\u8d35<\/td><\/tr><tr><td>\u4f20\u7edf\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/td><td>\u2605\u2605 \u51fa\u98ce\u504f\u6696<\/td><td>\u2605\u2605\u2605\u2605 \u8212\u9002<\/td><td>\u2605 \u6781\u590d\u6742<\/td><td>\u2605\u2605\u2605 \u4e2d\u7b49<\/td><td>\u91c7\u6696\u597d\u3001\u5236\u51b7\u5dee<\/td><\/tr><tr><td>\u5206\u4f53\u7a7a\u8c03 + \u7535\u6696\u5668\/\u6cb9\u6c40<\/td><td>\u2605\u2605 \u5c40\u90e8\u51b7<\/td><td>\u2605 \u6548\u679c\u5dee<\/td><td>\u2605\u2605\u2605\u2605 \u7b80\u5355<\/td><td>\u2605\u2605 \u7535\u8d39\u9ad8<\/td><td>\u4fbf\u5b9c\u4f46\u4f53\u9a8c\u5dee<\/td><\/tr><tr><td>\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u5feb\u51b7\u67d4\u98ce<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u5730\u9762\u8f90\u5c04<\/td><td>\u2605\u2605\u2605 \u6807\u51c6\u5b89\u88c5<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u8d39\u7528\u6700\u4f4e<\/td><td>\u4e24\u7aef\u517c\u4f18<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u77db\u76fe<\/strong>\uff1a\u6c1f\u7cfb\u7edf\u5236\u51b7\u5feb\u4f46\u4e0d\u64c5\u957f\u91c7\u6696\uff0c\u6c34\u7cfb\u7edf\u91c7\u6696\u8212\u9002\u4f46\u5236\u51b7\u62c9\u80ef\u3002\u7528\u6237\u88ab\u8feb\u4e8c\u9009\u4e00\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1.2 \u5357\u65b9\u5bb6\u5ead\u7684\u7279\u6b8a\u75db\u70b9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u6210\u90fd\u4e3a\u4ee3\u8868\u7684\u5357\u65b9\u57ce\u5e02\uff0c\u51b7\u6696\u9700\u6c42\u4e0e\u5317\u65b9\u622a\u7136\u4e0d\u540c\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u75db\u70b9\u7ef4\u5ea6<\/th><th>\u5177\u4f53\u8868\u73b0<\/th><th>\u667a\u4eab\u89e3\u51b3\u65b9\u6848<\/th><\/tr><\/thead><tbody><tr><td>\u6885\u96e8\u5b63\u9664\u6e7f<\/td><td>\u5899\u4f53\u53d1\u9709\u3001\u8863\u7269\u4e0d\u5e72\u3001\u547c\u5438\u9053\u75be\u75c5\u9ad8\u53d1<\/td><td>\u6e29\u6e7f\u53cc\u63a7\u5ba4\u5185\u673a\uff0c\u4e0d\u964d\u6e29\u9664\u6e7f<\/td><\/tr><tr><td>\u65e0\u96c6\u4e2d\u4f9b\u6696<\/td><td>\u51ac\u5b63\u5168\u9760\u81ea\u91c7\u6696\uff0c\u71c3\u6c14\u8d39\u7528\u9ad8\u6602<\/td><td>\u7a7a\u6c14\u80fd\u5730\u6696\uff0c\u8d39\u7528\u7ea6\u71c3\u6c14\u58c1\u6302\u708950-60%<\/td><\/tr><tr><td>\u5916\u673a\u4f4d\u7d27\u5f20<\/td><td>\u9ad8\u5c42\u5e73\u5c42\u8bbe\u5907\u5e73\u53f0\u7a7a\u95f4\u6709\u9650<\/td><td>\u4e00\u4f53\u5f0f\u8bbe\u8ba1\uff0c\u65e0\u9700\u989d\u5916\u6c34\u6a21\u5757\u7a7a\u95f4<\/td><\/tr><tr><td>\u5ffd\u51b7\u5ffd\u70ed<\/td><td>\u6625\u79cb\u8fc7\u6e21\u5b63\u6c14\u6e29\u6ce2\u52a8\u5927<\/td><td>\u667a\u80fd\u81ea\u9002\u5e94\u63a7\u6e29\uff0c\u5e73\u6ed1\u8fc7\u6e21<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">1.3 \u6570\u636e\u901f\u67e5\uff1a\u51b7\u6696\u65b9\u6848\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u5bf9\u6bd4\uff08120\u33a1\u6237\u578b\uff0c15\u5e74\u5468\u671f\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u8d39\u7528\u9879<\/th><th>\u6c1f\u673a+\u58c1\u6302\u7089<\/th><th>\u4f20\u7edf\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b<\/th><th>\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34<\/th><\/tr><\/thead><tbody><tr><td>\u521d\u88c5\u8d39\u7528\uff08\u4e07\u5143\uff09<\/td><td>4.5-5.5<\/td><td>5.0-6.5<\/td><td>3.5-4.5<\/td><\/tr><tr><td>\u5e74\u5747\u8fd0\u884c\u8d39\uff08\u5143\uff09<\/td><td>6,000-8,000<\/td><td>4,500-6,000<\/td><td>3,000-4,200<\/td><\/tr><tr><td>15\u5e74\u8fd0\u884c\u603b\u8d39\uff08\u4e07\u5143\uff09<\/td><td>9.0-12.0<\/td><td>6.8-9.0<\/td><td>4.5-6.3<\/td><\/tr><tr><td>\u7ef4\u62a4\u5e74\u5747\uff08\u5143\uff09<\/td><td>800-1,200<\/td><td>1,200-1,800<\/td><td>400-600<\/td><\/tr><tr><td>15\u5e74\u603b\u6301\u6709\u6210\u672c\uff08\u4e07\u5143\uff09<\/td><td>14.7-19.3<\/td><td>13.6-18.5<\/td><td>8.6-11.7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5de5\u51b5\u8bf4\u660e<\/strong>\uff1a\u6570\u636e\u57fa\u4e8e\u6210\u90fd120\u33a1\u4fdd\u6e29\u826f\u597d\u7684\u5e73\u5c42\u6237\u578b\uff0c\u5929\u7136\u6c14\u4ef7\u683c2.5\u5143\/m\u00b3\uff0c\u5c45\u6c11\u7528\u75350.55\u5143\/\u5ea6\u3002\u5177\u4f53\u8d39\u7528\u56e0\u623f\u5c4b\u4fdd\u6e29\u6761\u4ef6\u3001\u4f7f\u7528\u4e60\u60ef\u3001\u6c14\u5019\u5e74\u4efd\u800c\u5f02\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u572815\u5e74\u5468\u671f\u5185\u603b\u6301\u6709\u6210\u672c\u6bd4\u4f20\u7edf\u65b9\u6848\u4f4e30%-40%\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">1.4\u300160 \u79d2\u81ea\u6d4b\uff1a7 \u4e2a\u95ee\u9898\u5b9a\u4f4d\u60a8\u7684\u65b9\u6848<\/h3>\n\n<div style=\"background:#FAFBFC;border-left:4px solid #1a3a6e;padding:14px 18px;margin:14px 0;line-height:1.9;\">\n<p><b>1. \u65b0\u623f\u88c5\u4fee\uff0c\u8fd8\u662f\u5df2\u7ecf\u88c5\u4fee\u5165\u4f4f\uff1f<\/b><br>\u8fd9\u4e00\u6761\u57fa\u672c\u51b3\u5b9a\u5927\u65b9\u5411\uff1a\u672a\u88c5\u4fee\u4f18\u5148\u5730\u6696\uff0c\u5df2\u88c5\u4fee\u9009\u660e\u88c5\u6696\u6c14\u7247\u3002<br><span style=\"color:#5A6B7C;font-size:13.5px;\">\u6210\u90fd\u5ba2\u6237\u4e24\u79cd\u5e38\u89c1\u5f00\u573a\uff1a\"\u623f\u5b50\u672a\u88c5\u4fee\uff0c\u5728\u505a\u65b9\u6848\"\u548c\"\u65e7\u623f\u7ffb\u65b0\u3001\u6696\u6c14\u7ba1\u8def\u6539\u9020\"\u2014\u2014\u60a8\u5c5e\u4e8e\u54ea\u79cd\uff1f<\/span><\/p>\n\n<p><b>2. \u91c7\u6696\u9762\u79ef\u591a\u5927\uff1f\u4fdd\u6e29\u72b6\u51b5\u5982\u4f55\uff1f<\/b><br>\u897f\u6652\u3001\u843d\u5730\u7a97\u3001\u9876\u5c42\uff0c\u90fd\u4f1a\u5f71\u54cd\u6bcf\u4e2a\u623f\u95f4\u7684\u70ed\u8d1f\u8377\u53d6\u503c\u3002<\/p>\n\n<p><b>3. \u70ed\u6e90\u6761\u4ef6\uff1a\u6709\u6ca1\u6709\u71c3\u6c14\uff1f\u6709\u6ca1\u6709\u72ec\u7acb\u70ed\u6c34\u5668\uff1f<\/b><br>\u51b3\u5b9a\u58c1\u6302\u7089\u9009\u5355\u91c7\u6696\u7089\u8fd8\u662f\u4e24\u7528\u7089\u3002<\/p>\n\n<p><b>4. \u4f7f\u7528\u4e60\u60ef\uff1a\u56de\u5bb6\u624d\u5f00\uff0c\u8fd8\u662f\u957f\u671f\u6709\u4eba\uff1f\u54ea\u4e9b\u623f\u95f4\u5e38\u4f4f\uff1f<\/b><br>\u5f71\u54cd\u63a7\u5236\u7cfb\u7edf\u914d\u7f6e\u548c\u80fd\u8017\u9884\u671f\u3002\u6210\u90fd\u51ac\u591c\u6700\u4f4e 1\uff5e5\u2103\uff0c\u6709\u5ba2\u6237\u8bf4\"\u6e29\u5dee\u8d85\u8fc7 15 \u5ea6\u4e0d\u8212\u9002\"\u2014\u2014\u957f\u671f\u5e38\u4f4f\u548c\u56de\u5bb6\u624d\u5f00\uff0c\u914d\u6cd5\u4e0d\u4e00\u6837\u3002<\/p>\n\n<p><b>5. \u8fd9\u5957\u623f\u662f\u81ea\u4f4f\u8fd8\u662f\u6295\u8d44\uff1f\u66f4\u770b\u91cd\u524d\u671f\u603b\u6295\u5165\uff0c\u8fd8\u662f\u672a\u6765\u5341\u51e0\u5e74\u7684\u4f7f\u7528\u4e0e\u7ef4\u62a4\u6210\u672c\uff1f<\/b><br>\u81ea\u4f4f\u957f\u671f\u7528\uff0c\u5730\u6696\u7684\u8212\u9002\u548c\u8282\u80fd\u624d\u503c\u56de\u6295\u5165\uff1b\u6295\u8d44\u8fc7\u6e21\u623f\uff0c\u914d\u7f6e\u53ef\u4ee5\u4ece\u7b80\u3002<br><span style=\"color:#5A6B7C;font-size:13.5px;\">\u4e00\u4f4d\u5ba2\u6237\u7684\u987e\u8651\u5f88\u5178\u578b\uff1a\"\u7cfb\u7edf\u8d39\u7528\u5982\u679c\u592a\u9ad8\uff0c\u4f1a\u4e0d\u820d\u5f97\u7528\u3002\"\u91c7\u6696\u7cfb\u7edf\u88c5\u4e86\u4e0d\u6562\u5f00\uff0c\u7b49\u4e8e\u767d\u88c5\u2014\u2014\u8fd9\u7b14\u8d26\u52d8\u6d4b\u65f6\u6211\u4eec\u7b97\u7ed9\u60a8\u770b\u3002<\/span><\/p>\n\n<p><b>6. \u9884\u7b97\u6863\u4f4d\u5728\u54ea\u4e00\u6863\uff1f<\/b><br>\u5148\u5b9a\u533a\u95f4\u518d\u8c08\u914d\u7f6e\uff0c\u65b9\u6848\u4e0d\u5bb9\u6613\u88ab\u5e26\u504f\u3002<\/p>\n\n<p><b>7. \u5bb6\u91cc\u6709\u8001\u4eba\u5c0f\u5b69\u5417\uff1f\u8001\u4eba\u623f\u3001\u513f\u7ae5\u623f\u6709\u6ca1\u6709\u7279\u522b\u8981\u6c42\uff1f<\/b><br>\u8001\u4eba\u5bf9\u5ba4\u6e29\u7a33\u5b9a\u548c\u811a\u90e8\u6e29\u6696\u6700\u654f\u611f\uff0c\u513f\u7ae5\u623f\u6015\u8fc7\u70ed\u8fc7\u5e72\u3002\u6709\u8001\u4eba\u7684\u6237\u578b\uff0c\u5ba4\u6e29\u5747\u5300\u5ea6\u548c\u5206\u5ba4\u63a7\u5236\u8981\u5f80\u524d\u6392\u3002<br><span style=\"color:#5A6B7C;font-size:13.5px;\">\u771f\u5b9e\u6848\u4f8b\uff1a\u522b\u5885\u5ba2\u6237\u8981\u6c42\"\u8001\u4eba\u4f4f\u4e00\u697c\u3001\u907f\u76f4\u5439\u3001\u5ba4\u6e29 20\uff5e22\u2103\"\u2014\u2014\u8fd9\u7c7b\u8981\u6c42\u76f4\u63a5\u5f71\u54cd\u76d8\u7ba1\u5206\u533a\u548c\u5206\u5ba4\u63a7\u6e29\u7684\u8bbe\u8ba1\u3002<\/span><\/p>\n<\/div>\n\n\n\n<div class=\"lm-fit\">\n  <p class=\"lm-fit-t\">\u5148\u5bf9\u53f7\uff1a\u8fd9\u5957\u7cfb\u7edf\u9002\u4e0d\u9002\u5408\u60a8\u5bb6\uff1f<\/p>\n  <p><strong>\u2705 \u9002\u5408\uff1a<\/strong>\u65b0\u623f\u88c5\u4fee\u3001\u60f3\u7a7a\u8c03\u4e0e\u5730\u6696\u4e00\u5957\u641e\u5b9a\u5e76\u63a7\u5236\u521d\u671f\u6295\u5165\u7684\u5bb6\u5ead\uff1b\u770b\u91cd\u590d\u70ed\u6548\u679c\uff1b\u5bf9\u7a7a\u6c14\u8d28\u91cf\u6709\u8981\u6c42\uff0c\u53ef\u642d\u914d\u65e5\u7acb\u51c0\u5316\u5185\u673a\u5b9e\u73b0\u5185\u673a\u81ea\u6e05\u6d01\u3001\u9ad8\u6e29\u6d88\u6bd2\u4e0e PE \u751f\u6001\u51c0\u5316\uff08\u5185\u51c0\u5916\u6d01\uff09\u3002<\/p>\n  <p><strong>\u274c \u5148\u7b49\u7b49\uff0c\u5982\u679c\u60a8\u662f\u8fd9\u4e9b\u60c5\u51b5\uff1a<\/strong>\u5df2\u88c5\u4fee\u8001\u623f\u60f3\u52a0\u91c7\u6696\u2014\u2014\u522b\u7838\u5730\u576a\uff0c\u660e\u88c5\u6696\u6c14\u7247\u4e00\u81f3\u4e24\u5929\u88c5\u5b8c\uff08<a href=\"https:\/\/longmai-nt.com\/?page_id=12627\">\u660e\u88c5\u6696\u6c14\u7247<\/a>\uff09\uff1b\u5927\u5e73\u5c42\u3001\u522b\u5885\u8981\u6c34\u7cfb\u7edf\u67d4\u98ce\u2014\u2014\u6c34\u5885\u9002\u5168\u6c34\u7cfb\u7edf\uff08<a href=\"https:\/\/longmai-nt.com\/?page_id=14764\">\u6c34\u5885\u9002\u5168\u6c34\u7cfb\u7edf<\/a>\uff09\uff1b\u5bf9\u6e7f\u5ea6\u6781\u654f\u611f\u2014\u2014\u5c0a\u777f\u5168\u6548\u2161\u4e09\u7ba1\u5236\uff08<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u5c0a\u777f\u5168\u6548\u2161\u4e09\u7ba1\u5236<\/a>\uff09\u3002<\/p>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx02\" class=\"wp-block-heading\">\u7b2c\u4e8c\u7ae0\uff1a\u6280\u672f\u89e3\u6790\u2014\u2014\u5929\u6c1f\u5730\u6c34\u7684\u6839\u6280\u672f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">2.1 \u4e24\u8054\u4f9b\u884c\u4e1a\u53d1\u5c55\u7b80\u53f2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e24\u8054\u4f9b\uff08\u7a7a\u6c14\u6e90\u70ed\u6cf5\u4e24\u8054\u4f9b\uff09\u5e76\u975e\u65b0\u9c9c\u4e8b\u7269\uff0c\u5176\u6f14\u8fdb\u8109\u7edc\u6e05\u6670\u53ef\u8fa8\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9636\u6bb5<\/th><th>\u65f6\u95f4<\/th><th>\u7279\u5f81<\/th><th>\u4ee3\u8868\u4ea7\u54c1\u5f62\u6001<\/th><\/tr><\/thead><tbody><tr><td>\u8d77\u6e90\u671f<\/td><td>1990s-2005\u5e74<\/td><td>\u6b27\u6d32\u8d77\u6e90\uff0c\u89e3\u51b3\u71c3\u6c14\u4e0d\u8db3\u95ee\u9898<\/td><td>\u7eaf\u6c34\u7cfb\u7edf\uff0c\u5236\u51b7\u8212\u9002\u5ea6\u5dee<\/td><\/tr><tr><td>\u5f15\u5165\u671f<\/td><td>2005-2015\u5e74<\/td><td>\u56fd\u5185\u54c1\u724c\u5f15\u8fdb\uff0c\u522b\u5885\u573a\u666f\u8bd5\u6c34<\/td><td>\u6b27\u5f0f\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff0c\u6c34\u571f\u4e0d\u670d<\/td><\/tr><tr><td>\u8fed\u4ee3\u671f<\/td><td>2015-2020\u5e74<\/td><td>\u4f4e\u6e29\u5236\u70ed\u7a81\u7834\uff0c\"\u7164\u6539\u7535\"\u63a8\u52a8<\/td><td>\u4f4e\u6e29\u578b\u70ed\u6cf5\u4e24\u8054\u4f9b\u6d8c\u73b0<\/td><\/tr><tr><td>\u7206\u53d1\u671f<\/td><td>2020\u5e74\u81f3\u4eca<\/td><td>\u5e74\u589e30%+\uff0c2023\u5e74\u5e02\u573a\u7834120\u4ebf<\/td><td>\u5929\u6c1f\u5730\u6c34\/\u6c34\u7cfb\u7edf\/\u5730\u6e90\u70ed\u6cf5\u4e09\u8db3\u9f0e\u7acb<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2.2 \u5929\u6c1f\u5730\u6c34\u6280\u672f\u539f\u7406<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5929\u6c1f\u5730\u6c34\u662f\u65e5\u7acb2017\u5e74\u7387\u5148\u63a8\u51fa\u7684\u6280\u672f\u8def\u7ebf\uff0c\u6838\u5fc3\u601d\u60f3\u7b80\u800c\u8a00\u4e4b\uff1a<strong>\"\u6c1f\u51b7+\u6c34\u6696\uff0c\u5404\u53d6\u6240\u957f\"<\/strong>\u3002<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>\u5236\u51b7\u5faa\u73af\uff08\u6c1f\u7cfb\u7edf\uff09\uff1a\n\u4e3b\u673a\u538b\u7f29\u673a \u2192 \u4f4e\u6e29\u6c1f\u5229\u6602 \u2192 \u5ba4\u5185\u673a\u6362\u70ed\u5668 \u2192 \u51b7\u98ce\u5439\u51fa \u2192 \u6c1f\u5229\u6602\u56de\u4e3b\u673a\n\u2192 \u4e00\u6b21\u6362\u70ed\uff0c\u76f4\u51b7\u76f4\u8fbe\uff0c\u964d\u6e29\u5feb\u3001\u65e0\u51b7\u51dd\u6c34\u6ecb\u751f\n\n\u5236\u70ed\/\u5730\u6696\u5faa\u73af\uff08\u6c34\u7cfb\u7edf\uff09\uff1a\n\u4e3b\u673a\u538b\u7f29\u673a \u2192 \u9ad8\u6e29\u6c1f\u5229\u6602 \u2192 \u6c1f\u6c34\u6362\u70ed\u5668 \u2192 \u70ed\u6c34\u5faa\u73af \u2192 \u5730\u6696\u76d8\u7ba1 \u2192 \u5730\u9762\u8f90\u5c04\u6563\u70ed\n\u2192 \u6c1f\u2192\u6c34\u4e8c\u6b21\u6362\u70ed\uff0c\u5730\u9762\u5747\u5300\u6563\u70ed\uff0c\u4f53\u611f\u8212\u9002<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6c1f\u6c34\u6362\u70ed\u5668<\/strong>\u662f\u6838\u5fc3\u7ec4\u4ef6\uff0c\u53ef\u7406\u89e3\u4e3a\"\u4e00\u4e2a\u6ce1\u5728\u6c34\u91cc\u7684\u5ba4\u5185\u673a\"\u2014\u2014\u5c06\u6c1f\u5229\u6602\u643a\u5e26\u7684\u70ed\u91cf\u5151\u6362\u6210\u70ed\u6c34\uff0c\u8f93\u9001\u5230\u5730\u6696\u76d8\u7ba1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5207\u6362\u673a\u5236<\/strong>\uff1a\u4e3b\u673a\u5185\u7f6e\u6362\u5411\u9600\u548c\u63a7\u5236\u7cfb\u7edf\uff0c\u5236\u51b7\/\u5730\u6696\u6a21\u5f0f\u81ea\u52a8\u5207\u6362\uff0c\u7528\u6237\u65e0\u9700\u624b\u52a8\u5e72\u9884\u3002<\/p>\n\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg\" alt=\"\u65e5\u7acb\u667a\u4eab\u53cc\u63a7\u578b\u4e24\u8054\u4f9b\u7cfb\u7edf\u539f\u7406\u56fe\uff1a\u5ba4\u5916\u673a\u3001\u6c34\u6a21\u5757\u3001\u5730\u6696\u76d8\u7ba1\u4e0e\u5ba4\u5185\u673a\u7684\u8fde\u63a5\u5173\u7cfb\" loading=\"lazy\" style=\"max-width:100%;height:auto;\">\n<figcaption>\u667a\u4eab\u7684\u7cfb\u7edf\u8d70\u5411\u3002\u5ba4\u5916\u673a\u628a\u51b7\u5a92\u9001\u8fdb\u6c34\u6a21\u5757\uff0c\u6c34\u6a21\u5757\u6362\u6210\u70ed\u6c34\uff0c\u70ed\u6c34\u518d\u8fdb\u5730\u6696\u76d8\u7ba1\u2014\u2014\u5929\u4e0a\u8d70\u6c1f\u3001\u5730\u4e0a\u8d70\u6c34\uff0c\u8f6c\u6362\u5c31\u5728\u6c34\u6a21\u5757\u8fd9\u4e00\u6b65\u3002\u540c\u4e00\u53f0\u5916\u673a\u65e2\u4f9b\u7a7a\u8c03\u5185\u673a\uff0c\u4e5f\u4f9b\u6c34\u6a21\u5757\u3002<\/figcaption>\n<\/figure>\n\n\n\n\n<h3 class=\"wp-block-heading\">2.2.1 \u5148\u628a\u4e24\u6761\u4ea7\u54c1\u7ebf\u5206\u5f00\uff1aAQ \u548c NQ \u4e0d\u662f\u4e00\u53f0\u673a\u5668\u7684\u4e94\u6863\u516d\u6863<\/h3>\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acb\u667a\u4eab\u4e0d\u662f\u4e00\u4e2a\u7cfb\u5217\u91cc\u6863\u4f4d\u591a\u5c11\u7684\u5dee\u522b\uff0c\u662f\u4e24\u6761\u5206\u5f00\u5356\u7684\u4ea7\u54c1\u7ebf\u3002\u540d\u5b57\u90fd\u53eb\u667a\u4eab\uff0c\u540e\u7f00\u5dee\u4e00\u4e2a\u5b57\u6bcd\uff0c\u914d\u7684\u4e1c\u897f\u5c31\u4e0d\u4e00\u6837\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u53cc\u63a7\u578b AQ<\/th><th>\u5355\u63a7\u578b NQ<\/th><\/tr><\/thead><tbody><tr><td>\u578b\u53f7\u540e\u7f00<\/td><td>FSPUNAQ<\/td><td>FSPUNQ\uff08220V\uff09\uff0fFSPUNYQ\uff08380V\uff0cY \u4ee3\u8868\u4e09\u76f8\uff09<\/td><\/tr><tr><td>220V \u6863\u4f4d<\/td><td>80 \/ 100 \/ 125 \/ 140 \/ 160\uff0c\u4e94\u6863<\/td><td>100 \/ 125 \/ 140 \/ 160 \/ 180 \/ 200\uff0c\u516d\u6863<\/td><\/tr><tr><td>380V \u6863\u4f4d<\/td><td>\u6ca1\u6709<\/td><td>224 \/ 240 \/ 280 \/ 320\uff0c\u56db\u6863<\/td><\/tr><tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u6709\uff0c\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00<\/td><td>\u6ca1\u6709\uff0c\u8981\u6d17\u6fa1\u53e6\u914d\u70ed\u6c34\u5668<\/td><\/tr><tr><td>\u5faa\u73af\u6c34\u6cf5<\/td><td>\u4e0d\u6807\u914d\uff0c\u8981\u53e6\u914d<\/td><td>\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5<\/td><\/tr><tr><td>\u6c34\u6e29<\/td><td>\u624b\u52a8\u8bbe\u5b9a<\/td><td>\u6309\u5ba4\u5916\u6e29\u5ea6\u81ea\u52a8\u8c03<\/td><\/tr><tr><td>\u8fde\u63a5\u7387\u533a\u95f4<\/td><td>50%~130%<\/td><td>50%~150%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u4e24\u6761\u7ebf\u6ca1\u6709\u4e0a\u4e0b\u7ea7\uff0c\u662f\u4e24\u79cd\u7528\u6cd5\uff1a\u5bb6\u91cc\u8981\u751f\u6d3b\u70ed\u6c34\u3001\u6237\u578b\u4e0d\u5927\uff0c\u8d70 AQ\uff1b\u53ea\u505a\u7a7a\u8c03\u52a0\u5730\u6696\u3001\u9762\u79ef\u5f80\u4e2d\u5927\u6237\u578b\u8d70\uff0c\u8d70 NQ\u3002<strong>\u628a\u4e24\u6761\u7ebf\u6df7\u7740\u6570\u6863\u4f4d\uff0c\u5c31\u4f1a\u6570\u51fa\"\u5230\u5e95\u4e94\u6863\u8fd8\u662f\u516d\u6863\"\u8fd9\u79cd\u95ee\u9898\u2014\u2014\u672c\u6765\u5404\u6570\u5404\u7684\u3002<\/strong><\/p>\n\n<h3 class=\"wp-block-heading\">2.3 \u53cc\u63a7\u578b AQ\uff08\u5929\u6c1f\u70ed\u6c34\u4e00\u4f53\u673a\uff09\u5168\u7cfb\u5217\u53c2\u6570\u8868<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">AQ = \u4e00\u4f53\u5f0f\uff0c\u6c34\u6a21\u5757\u548c\u70ed\u6c34\u6362\u70ed\u90fd\u5728\u673a\u5668\u91cc\uff0c\u7b7e\u5355\u65f6\u4e0d\u7528\u53e6\u9009\u6c34\u6a21\u5757\u3002<strong>\u80fd\u51fa\u751f\u6d3b\u70ed\u6c34\uff0c\u4f46\u70ed\u6c34\u548c\u5730\u6696\u4e8c\u9009\u4e00<\/strong>\uff0c\u540c\u4e00\u65f6\u95f4\u53ea\u8d70\u4e00\u4e2a\u529f\u80fd\u3002<br>\u5168\u7cfb 220V \u5355\u76f8\u7535\uff0c\u5355\u98ce\u6247\u8bbe\u8ba1\uff0c\u9002\u914d\u5c0f\u6237\u578b\u3001\u5e73\u5c42\u3002<\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u578b\u53f7<\/th><th>\u7535\u6e90<\/th><th>\u5236\u51b7(kW)<\/th><th>\u5236\u70ed(kW)<\/th><th>APF<\/th><th>IPLV<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u51c0\u91cd(kg)<\/th><th>\u5c3a\u5bf8H\u00d7W\u00d7D(mm)<\/th><\/tr><\/thead><tbody><tr><td>RAS-80FSPUNAQ<\/td><td>220V<\/td><td>8.0<\/td><td>9.0<\/td><td>6.15<\/td><td>7.6<\/td><td>49<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-100FSPUNAQ<\/td><td>220V<\/td><td>10.0<\/td><td>11.2<\/td><td>6.15<\/td><td>7.4<\/td><td>50<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-125FSPUNAQ<\/td><td>220V<\/td><td>12.5<\/td><td>14.0<\/td><td>5.8<\/td><td>7.2<\/td><td>51<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-140FSPUNAQ<\/td><td>220V<\/td><td>14.0<\/td><td>16.0<\/td><td>5.6<\/td><td>7.0<\/td><td>52<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-160FSPUNAQ<\/td><td>220V<\/td><td>15.5<\/td><td>18.0<\/td><td>5.5<\/td><td>6.8<\/td><td>53<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7279\u70b9<\/strong>\uff1aAPF \u6700\u9ad8 6.15\uff0880\/100 \u578b\uff09\uff0c\u5168\u7cfb\u8d85\u4e00\u7ea7\u80fd\u6548\uff1b\u4e00\u4f53\u5f0f\u8bbe\u8ba1\uff0c\u5916\u673a\u4f4d\u5360\u7528\u4ec5 0.92\u33a1\uff1b<strong>\u4e0d\u6807\u914d\u5faa\u73af\u6c34\u6cf5\uff0c\u8981\u53e6\u914d<\/strong>\uff0c\u6c34\u6e29\u4e5f\u8981\u81ea\u5df1\u8bbe\u2014\u2014\u8fd9\u4e24\u9879\u5728\u62a5\u4ef7\u91cc\u5e38\u662f\u5355\u72ec\u4e00\u884c\uff0c\u7b7e\u5408\u540c\u524d\u95ee\u6e05\u695a\u542b\u4e0d\u542b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9002\u7528\u9762\u79ef\uff1a\u7ea6 90-160\u33a1<\/p>\n\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-3-6hpzts-zx-wzsbxtylt.jpg\" alt=\"\u65e5\u7acb\u667a\u4eabAQ\u5916\u7f6e\u6c34\u6cf5\u7cfb\u7edf\u539f\u7406\u56fe\uff1a\u5faa\u73af\u6c34\u6cf5\u88c5\u5728\u5ba4\u5916\u673a\u5916\u90e8\uff0c\u9700\u53e6\u914d\" loading=\"lazy\" style=\"max-width:100%;height:auto;\">\n<figcaption>AQ \u7684\u7cfb\u7edf\u56fe\u3002\u7559\u610f\u6c34\u6cf5\u753b\u5728\u5ba4\u5916\u673a\u5916\u9762\u2014\u2014AQ \u4e0d\u6807\u914d\u5faa\u73af\u6c34\u6cf5\uff0c\u8fd9\u4e00\u4ef6\u8981\u5355\u72ec\u914d\u3002\u6240\u4ee5\u5b9a\u673a\u5668\u4e4b\u524d\u5148\u5b9a\u6cf5\u653e\u54ea\uff0c\u522b\u7b49\u673a\u5668\u5230\u4e86\u518d\u627e\u5730\u65b9\u3002<\/figcaption>\n<\/figure>\n\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">2.4 \u5355\u63a7\u578b NQ\uff08\u5929\u6c1f\u5730\u6c34\u4e00\u4f53\u673a\uff09\u5168\u7cfb\u5217\u53c2\u6570\u8868<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><code>NQ = \u4e00\u4f53\u5f0f\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\uff0c\u4e0d\u9700\u8981\u53e6\u9009\u6c34\u6a21\u5757\u3002\u7eaf\u4e24\u8054\u4f9b\uff0c\u65e0\u751f\u6d3b\u70ed\u6c34\u3002<\/code><\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>220V \u5355\u76f8\u7cfb\u5217\uff08\u516d\u6863\uff09<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u578b\u53f7<\/th><th>\u7535\u6e90<\/th><th>\u5236\u51b7(kW)<\/th><th>\u5236\u70ed(kW)<\/th><th>APF<\/th><th>IPLV<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u51c0\u91cd(kg)<\/th><th>\u5c3a\u5bf8H\u00d7W\u00d7D(mm)<\/th><\/tr><\/thead><tbody><tr><td>RAS-100FSPUNQ<\/td><td>220V<\/td><td>10.0<\/td><td>11.2<\/td><td>5.8<\/td><td>7.2<\/td><td>50<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-125FSPUNQ<\/td><td>220V<\/td><td>12.5<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>RAS-140FSPUNQ<\/td><td>220V<\/td><td>14.0<\/td><td>16.0<\/td><td>5.6<\/td><td>7.0<\/td><td>52<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-160FSPUNQ<\/td><td>220V<\/td><td>15.5<\/td><td>18.0<\/td><td>5.5<\/td><td>6.8<\/td><td>53<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-180FSPUNQ<\/td><td>220V<\/td><td>18.0<\/td><td>20.0<\/td><td>5.3<\/td><td>6.5<\/td><td>54<\/td><td>\u2014<\/td><td>840\u00d71100\u00d7390<\/td><\/tr><tr><td>RAS-200FSPUNQ<\/td><td>220V<\/td><td>20.0<\/td><td>22.4<\/td><td>5.3<\/td><td>6.5<\/td><td>54<\/td><td>\u2014<\/td><td>950\u00d71250\u00d7340<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u8868\u91cc\u6807\"\u2014\"\u7684\u683c\u5b50\uff0c\u662f\u6ca1\u62ff\u5230\u6837\u518c\u6570\u636e\u7684\u9879\u3002\u4ee5\u65e5\u7acb\u5b98\u65b9\u6700\u65b0\u6837\u518c\u4e3a\u51c6\uff0c\u672c\u9875\u4e0d\u5199\u4f30\u7b97\u6570\u3002<\/p>\n\n\n\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-100-200zts-zx-xtylt.jpg\" alt=\"\u65e5\u7acb\u667a\u4eabNQ\u6574\u4f53\u5f0f\u7cfb\u7edf\u539f\u7406\u56fe\uff1a100\u81f3200\u578b\uff0c\u6c34\u6a21\u5757\u4e0e\u6c34\u6cf5\u5185\u7f6e\" loading=\"lazy\" style=\"max-width:100%;height:auto;\">\n<figcaption>NQ \u7684\u7cfb\u7edf\u56fe\uff08100~200 \u578b\uff09\u3002\u6c34\u6cf5\u753b\u5728\u673a\u5668\u5185\u90e8\uff0c\u51fa\u5382\u5c31\u5e26\uff1b\u6c34\u6e29\u6309\u5ba4\u5916\u6e29\u5ea6\u81ea\u52a8\u8c03\u3002\u56fe\u91cc\u6ca1\u6709\u751f\u6d3b\u70ed\u6c34\u90a3\u4e00\u8def\uff0c\u56e0\u4e3a NQ \u4e0d\u505a\u70ed\u6c34\u3002<\/figcaption>\n<\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>380V \u4e09\u76f8\u7cfb\u5217\uff08\u56db\u6863\uff0c\u8865\u6c14\u589e\u7113\uff0c\u6781\u7aef\u4f4e\u6e29\u66f4\u7a33\u5b9a\uff09<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u578b\u53f7<\/th><th>\u7535\u6e90<\/th><th>\u5236\u51b7(kW)<\/th><th>\u5236\u70ed(kW)<\/th><th>APF<\/th><th>IPLV<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u51c0\u91cd(kg)<\/th><th>\u5c3a\u5bf8H\u00d7W\u00d7D(mm)<\/th><\/tr><\/thead><tbody><tr><td>RAS-224FSPUNYQ<\/td><td>380V<\/td><td>22.4<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>RAS-240FSPUNYQ<\/td><td>380V<\/td><td>24.0<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>RAS-280FSPUNYQ<\/td><td>380V<\/td><td>28.0<\/td><td>31.5<\/td><td>5.1<\/td><td>6.1<\/td><td>56<\/td><td>\u2014<\/td><td>1380\u00d7950\u00d7320<\/td><\/tr><tr><td>RAS-320FSPUNYQ<\/td><td>380V<\/td><td>32.0<\/td><td>32.0<\/td><td>5.0<\/td><td>6.0<\/td><td>57<\/td><td>\u2014<\/td><td>1380\u00d7950\u00d7320<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7279\u70b9<\/strong>\uff1a224 \u578b\u4ee5\u4e0a\u642d\u8f7d\u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a\uff0c-25\u2103\u6781\u7aef\u4f4e\u6e29\u5236\u70ed\u66f4\u7a33\u5b9a\uff1b380V \u4e09\u76f8\u7535\u9a71\u52a8\uff0c\u9002\u5408\u5927\u5e73\u5c42\u548c\u522b\u5885\uff1b<code>\u6c34\u6a21\u5757\u5185\u7f6e\u5916\u673a\uff0c\u4e0d\u5e26\u751f\u6d3b\u70ed\u6c34<\/code>\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9002\u7528\u9762\u79ef\uff1a\u7ea6100-320\u33a1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5177\u4f53\u53c2\u6570\u4ee5\u65e5\u7acb\u5b98\u65b9\u6700\u65b0\u6837\u518c\u4e3a\u51c6\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">2.5 \u6838\u5fc3\u7ec4\u4ef6\u6280\u672f\u6df1\u89e3<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u538b\u7f29\u673a\uff1a\u76f4\u6d41\u53d8\u9891\u53cc\u8f6c\u5b50\uff08AQ\/\u5c0fNQ\uff09+ \u8865\u6c14\u589e\u7113\u6da1\u65cb\uff08\u5927NQ\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acb\u667a\u4eab\u5168\u7cfb\u642d\u8f7d\u9ad8\u6548\u538b\u7f29\u673a\u3002AQ\u7cfb\u5217\u548c\u5c0f\u578bNQ\uff08100-180\u578b\uff09\u91c7\u7528\u76f4\u6d41\u53d8\u9891\u53cc\u8f6c\u5b50\uff0c\u4f4e\u9891\u8fd0\u884c\u5e73\u7a33\u3001\u9ad8\u9891\u8f93\u51fa\u5f3a\u52b2\uff1b\u5927\u578bNQ\uff08200-320\u578b\uff09\u5347\u7ea7\u4e3a\u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a\uff0c\u6781\u7aef\u4f4e\u6e29\u6027\u80fd\u66f4\u4f18\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u8865\u6c14\u589e\u7113\u6280\u672f<\/strong>\uff1a-20\u2103\u73af\u5883\u4e0b\u7a33\u5b9a\u5236\u70ed\uff0c-25\u2103\u4ecd\u53ef\u6b63\u5e38\u542f\u52a8<\/li>\n\n\n\n<li><strong>\u5bbd\u9891\u8c03\u901f<\/strong>\uff1a10Hz-120Hz\u65e0\u7ea7\u53d8\u9891\uff0c\u7cbe\u51c6\u5339\u914d\u8d1f\u8377<\/li>\n\n\n\n<li><strong>\u8bbe\u8ba1\u5bff\u547d<\/strong>\uff1a15\u5e74\u4ee5\u4e0a\uff0c\u65e5\u7acb\u539f\u88c5\u54c1\u63a7<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u667a\u80fd\u9664\u971c\u7b97\u6cd5<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acb\u4e13\u5229\"\u57fa\u4e8e\u73af\u5883\u6e29\u6e7f\u5ea6\u7684\u52a8\u6001\u9664\u971c\u7b97\u6cd5\"\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u4f20\u7edf\u5b9a\u65f6\u9664\u971c<\/th><th>\u667a\u4eab\u667a\u80fd\u9664\u971c<\/th><\/tr><\/thead><tbody><tr><td>\u9664\u971c\u89e6\u53d1<\/td><td>\u56fa\u5b9a\u65f6\u95f4\u95f4\u9694<\/td><td>\u6839\u636e\u5ba4\u5916\u6e29\u6e7f\u5ea6\u52a8\u6001\u5224\u65ad<\/td><\/tr><tr><td>\u9664\u971c\u65f6\u957f<\/td><td>\u56fa\u5b9a\u65f6\u957f\uff0c\u5e38\u8fc7\u5ea6\u9664\u971c<\/td><td>\u6309\u9700\u9664\u971c\uff0c\u89c1\u971c\u5373\u505c<\/td><\/tr><tr><td>\u9664\u971c\u80fd\u8017<\/td><td>\u5360\u5236\u70ed\u80fd\u801715-20%<\/td><td>\u5360\u5236\u70ed\u80fd\u80178-12%<\/td><\/tr><tr><td>\u5236\u70ed\u4e2d\u65ad<\/td><td>\u6bcf\u6b21\u9664\u971c\u4e2d\u65ad8-12\u5206\u949f<\/td><td>\u7f29\u77ed30%\uff0c\u7ea65-8\u5206\u949f<\/td><\/tr><tr><td>\u51ac\u5b63\u5236\u70ed\u7a33\u5b9a\u6027<\/td><td>\u57fa\u51c6<\/td><td>\u63d0\u534725%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">AQ \u7684\u70ed\u6c34\uff0c\u548c\u5730\u6696\u662f\u4e8c\u9009\u4e00<\/h4>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u662f AQ \u6700\u5bb9\u6613\u88ab\u8bb2\u6b6a\u7684\u4e00\u70b9\u3002\u5b83\u7684\u70ed\u6e90\u53ea\u6709\u4e00\u4e2a\uff0c\u751f\u6d3b\u70ed\u6c34\u4f18\u5148\uff1a\u6d17\u6fa1\u7684\u65f6\u5019\u70ed\u6c34\u5728\u70e7\uff0c\u5730\u6696\u90a3\u4e00\u8def\u662f\u505c\u7684\uff0c\u6d17\u5b8c\u518d\u56de\u5230\u91c7\u6696\u3002\u6240\u4ee5\u5b83\u505a\u4e0d\u5230\u300c\u4e00\u8fb9\u5236\u51b7\u5374\u4e00\u8fb9\u70e7\u70ed\u6c34\u300d\uff0c\u4e5f\u4e0d\u662f\u70ed\u6c34\u968f\u4fbf\u7528\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u4e2a\u7279\u6027\u51b3\u5b9a\u4e86 AQ \u9002\u5408\u4ec0\u4e48\u4eba\uff1a\u5bb6\u91cc\u672c\u6765\u5c31\u8981\u88c5\u70ed\u6c34\u5668\u3001\u53c8\u4e0d\u60f3\u591a\u5360\u4e00\u4e2a\u4f4d\u7f6e\u7684\uff0cAQ \u628a\u70ed\u6c34\u5668\u7684\u4f4d\u7f6e\u548c\u94b1\u7701\u4e0b\u6765\u4e86\u3002\u4f46\u5982\u679c\u4f60\u8981\u6c42\u51ac\u5929\u6d17\u6fa1\u65f6\u5730\u6696\u4e0d\u80fd\u505c\uff0c\u90a3\u5c31\u4e0d\u662f AQ \u7684\u6d3b\u2014\u2014\u90a3\u6761\u8def\u662f\u5c0a\u777f\u5168\u6548\u2161 \u52a0\u70ed\u6c34\u7bb1\u505a\u4e09\u8054\u4f9b\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u5168\u6548\u2161 \u4ea7\u54c1\u8be6\u60c5<\/a>\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx03\" class=\"wp-block-heading\">\u7b2c\u4e09\u7ae0\uff1a\u7834\u9664\u8bef\u533a\u2014\u2014\u5929\u6c1f\u5730\u6c34\u8ba4\u77e5\u7ea0\u504f<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">3.1 \"\u6c1f\u7cfb\u7edf\u6709\u6bd2\/\u4e0d\u5065\u5eb7\uff1f\"<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a<\/strong>\uff1a\u6c1f\u5229\u6602\u5236\u51b7\u5242\u5bf9\u4eba\u4f53\u6709\u5bb3\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e8b\u5b9e<\/strong>\uff1a\u65e5\u7acb\u91c7\u7528R410A\u73af\u4fdd\u51b7\u5a92\uff0cODP\uff08\u81ed\u6c27\u7834\u574f\u6307\u6570\uff09=0\u3002\u6c1f\u5229\u6602\u4ec5\u5728\u5c01\u95ed\u94dc\u7ba1\u56de\u8def\u4e2d\u5faa\u73af\uff0c\u4e0e\u5ba4\u5185\u7a7a\u6c14<strong>\u96f6\u63a5\u89e6<\/strong>\u3002\u5ba4\u5185\u673a\u5439\u51fa\u7684\u98ce\u662f\u5ba4\u5185\u7a7a\u6c14\u7ecf\u8fc7\u6362\u70ed\u5668\u964d\u6e29\u540e\u7684\u6d01\u51c0\u98ce\uff0c\u4e0d\u542b\u4efb\u4f55\u5236\u51b7\u5242\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.2 \"\u5929\u6c1f\u5730\u6c34\u4e0d\u5982\u7eaf\u6c34\u7cfb\u7edf\u8212\u9002\uff1f\"<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a<\/strong>\uff1a\u6c34\u7cfb\u7edf\"\u5982\u6c90\u6625\u98ce\"\uff0c\u6c1f\u7cfb\u7edf\"\u5e72\u51b7\u523a\u9aa8\"\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e8b\u5b9e<\/strong>\uff1a\u8fd9\u662f\u4e00\u4e2a\u88ab\u8fc7\u5ea6\u7b80\u5316\u7684\u5bf9\u6bd4\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u5929\u6c1f\u5730\u6c34\uff08\u667a\u4eab\uff09<\/th><th>\u5929\u6c34\u5730\u6c34\uff08\u6c34\u5885\u9002\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u7a7a\u8c03\u4fa7\u539f\u7406<\/td><td>\u6c1f\u5229\u6602\u76f4\u51b7\uff0c\u4e00\u6b21\u6362\u70ed<\/td><td>\u6c34\u5e26\u98ce\uff0c\u4e8c\u6b21\u6362\u70ed<\/td><\/tr><tr><td>\u51fa\u98ce\u6e29\u5ea6<\/td><td>5-14\u2103<\/td><td>7-25\u2103<\/td><\/tr><tr><td>\u5236\u51b7\u901f\u5ea6<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u6781\u5feb<\/td><td>\u2605\u2605\u2605 \u8f83\u6162<\/td><\/tr><tr><td>\u9664\u6e7f\u80fd\u529b<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u53ef\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/td><td>\u2605\u2605 \u4f9d\u8d56\u5236\u51b7\u9664\u6e7f<\/td><\/tr><tr><td>\u5730\u6696\u4fa7<\/td><td>\u6c34\u7cfb\u7edf\uff0c\u5730\u9762\u8f90\u5c04<\/td><td>\u6c34\u7cfb\u7edf\uff0c\u5730\u9762\u8f90\u5c04<\/td><\/tr><tr><td>\u5065\u5eb7\u529f\u80fd<\/td><td>\u6807\u914d\u81ea\u6e05\u6d01+PE\u51c0\u5316+\u9ad8\u6e29\u6d88\u6bd2<\/td><td>\u9700\u9009\u914d\uff0c\u90e8\u5206\u65e0\u81ea\u6e05\u6d01<\/td><\/tr><tr><td>\u9002\u7528\u4eba\u7fa4<\/td><td>\u9664\u6e7f\u521a\u9700\u3001\u6015\u70ed\u3001\u8ffd\u6c42\u5feb\u51b7<\/td><td>\u7a7a\u8c03\u9762\u79ef\u5927\u3001\u5e38\u4f4f\u4eba\u53e3\u5c11\uff08\u522b\u5885\u53ea\u4f4f\u4e24\u4e09\u4eba\uff09<\/td><\/tr><tr><td>\u5b89\u88c5\u590d\u6742\u5ea6<\/td><td>\u2605\u2605\u2605 \u6807\u51c6<\/td><td>\u2605 \u6781\u9ad8\uff0c\u9700\u6c34\u529b\u8ba1\u7b97+\u7f13\u51b2\u6c34\u7bb1<\/td><\/tr><tr><td>\u667a\u80fd\u63a7\u5236<\/td><td>\u6807\u914d5G\u7269\u8054\uff0cOTA\u5347\u7ea7<\/td><td>\u57fa\u7840WiFi\u63a7\u5236<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a\u4e24\u8005\u7684\u5dee\u5f02\u4e3b\u8981\u5728<strong>\u7a7a\u8c03\u4fa7<\/strong>\uff0c\u5730\u6696\u4fa7\u4f53\u9a8c\u8d8b\u540c\u3002\u5357\u65b9\u6885\u96e8\u5b63\u9664\u6e7f\u521a\u9700\u7528\u6237\u4f18\u5148\u9009\u5929\u6c1f\u5730\u6c34\uff1b\u6015\u51b7\u98ce\u3001\u60f3\u8981\u66f4\u67d4\u7684\u98ce\u611f\u7684\uff0c\u5148\u4e0a\u5c0a\u777f\u5168\u6548\u2161 \u4e09\u7ba1\u5236\u2014\u2014\u8212\u723d\u6a21\u5f0f\u4e0e\u5168\u5c4b\u5168\u611f\u9ad8\u663e\u70ed\u6a21\u5f0f\u80fd\u628a\u51fa\u98ce\u6e29\u5ea6\u63d0\u4e0a\u53bb\uff0c\u4e0d\u5fc5\u4e3a\u6b64\u6362\u6210\u6c34\u7cfb\u7edf\u3002\u771f\u6b63\u8be5\u770b\u6c34\u5885\u9002\u7684\u662f\u53e6\u4e00\u79cd\u60c5\u51b5\uff1a\u7a7a\u8c03\u9762\u79ef\u5927\u3001\u5e38\u4f4f\u4eba\u53e3\u5c11\uff08\u522b\u5885\u53ea\u4f4f\u4e24\u4e09\u4eba\uff09\uff0c\u4e3b\u673a\u53ef\u6309\u5b9e\u9645\u4f7f\u7528\u9762\u79ef\u914d\u3001\u4e0d\u53d7\u8fde\u63a5\u7387\u9650\u5236\uff0c\u4e00\u6b21\u6295\u5165\u548c\u65e5\u540e\u4f7f\u7528\u90fd\u66f4\u7701\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.3 \"\u7a7a\u6c14\u80fd\u91c7\u6696\u51ac\u5929\u4e0d\u591f\u70ed\uff1f\"<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a<\/strong>\uff1a\u51ac\u5929\u96f6\u4e0b\u65f6\u70ed\u6cf5\u5236\u70ed\u8870\u51cf\u4e25\u91cd\uff0c\u4e0d\u5982\u71c3\u6c14\u9505\u7089\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e8b\u5b9e<\/strong>\uff1a\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a\u4f7f\u667a\u4eab\u5728-20\u2103\u73af\u5883\u4e0b\u4ecd\u7a33\u5b9a\u8fd0\u884c\uff0c\u5730\u6696\u51fa\u6c34\u53ef\u8fbe55\u2103\u3002\u4ee5\u4e0b\u4e3a\u5b9e\u6d4b\u6570\u636e\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5ba4\u5916\u6e29\u5ea6<\/th><th>\u5236\u70edCOP<\/th><th>\u5730\u6696\u51fa\u6c34\u6e29\u5ea6<\/th><th>\u91c7\u6696\u6548\u679c<\/th><\/tr><\/thead><tbody><tr><td>7\u2103<\/td><td>4.0-4.5<\/td><td>45-55\u2103<\/td><td>\u6700\u4f73\u5de5\u51b5<\/td><\/tr><tr><td>0\u2103<\/td><td>3.2-3.5<\/td><td>40-50\u2103<\/td><td>\u6b63\u5e38\u8fd0\u884c<\/td><\/tr><tr><td>-7\u2103<\/td><td>2.5-2.8<\/td><td>38-45\u2103<\/td><td>\u6b63\u5e38\u91c7\u6696<\/td><\/tr><tr><td>-15\u2103<\/td><td>2.0-2.3<\/td><td>35-40\u2103<\/td><td>\u53ef\u7ef4\u6301\u5ba4\u6e2918-20\u2103<\/td><\/tr><tr><td>-20\u2103<\/td><td>1.8-2.0<\/td><td>32-38\u2103<\/td><td>\u6781\u7aef\u5929\u6c14\u53ef\u8fd0\u884c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.4 \"\u4e00\u4f53\u673a\u7ef4\u4fee\u9ebb\u70e6\uff1f\"<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bef\u533a<\/strong>\uff1a\u4e3b\u673a\u548c\u6c34\u6a21\u5757\u96c6\u6210\u5728\u4e00\u8d77\uff0c\u574f\u4e86\u5c31\u5f97\u6574\u673a\u6362\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e8b\u5b9e<\/strong>\uff1a\u4e00\u4f53\u5f0f\u96c6\u6210\u5e76\u975e\"\u710a\u6b7b\u5728\u4e00\u8d77\"\uff0c\u800c\u662f\u7ed3\u6784\u6574\u5408\u3001\u529f\u80fd\u72ec\u7acb\u3002\u6c34\u529b\u6a21\u5757\u3001\u538b\u7f29\u673a\u3001\u6362\u70ed\u5668\u3001\u7535\u63a7\u677f\u5747\u4e3a\u72ec\u7acb\u53ef\u66f4\u6362\u7ec4\u4ef6\u3002\u65e5\u7acb\u5168\u56fd2000+\u670d\u52a1\u7f51\u70b9\uff0c\u6574\u673a\u4fdd\u4fee3\u5e74\uff0c\u538b\u7f29\u673a\u4fdd\u4fee5\u5e74\uff0c\u6545\u969c\u7387\u4f4e\u4e8e\u4f20\u7edf\u5206\u4f53\u5f0f\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b20%\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx04\" class=\"wp-block-heading\">\u7b2c\u56db\u7ae0\uff1a\u667a\u4eab\u7684\u4e24\u6761\u4ea7\u54c1\u7ebf\u2014\u2014AQ \u548c NQ \u600e\u4e48\u5206<\/h2>\n\n<p>\u5929\u6c1f\u5730\u6c34\u8fd9\u6761\u8def\u5b9e\u9645\u6709\u56db\u79cd\u914d\u6cd5\uff0c\u667a\u4eab\u5360\u5176\u4e2d\u4e24\u6761\u2014\u2014AQ \u548c NQ\u3002\u8fd9\u4e00\u7ae0\u53ea\u8bb2\u667a\u4eab\u8fd9\u4e24\u6761\uff1a\u5b83\u4eec\u5dee\u5728\u54ea\u3001\u5404\u81ea\u914d\u4ec0\u4e48\u5185\u673a\u3001\u80fd\u4e0d\u80fd\u5347\u7ea7\u4e94\u6052\u3002\u5168\u6548\u2161 \u548c\u522b\u5885\u90a3\u4e24\u6761\u600e\u4e48\u8ddf\u667a\u4eab\u6bd4\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u914d\u6cd5<\/strong><\/td><td><strong>\u5916\u673a<\/strong><\/td><td><strong>\u6c34\u6a21\u5757<\/strong><\/td><td><strong>\u5ba4\u5185\u673a<\/strong><\/td><td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td><td><strong>\u9002\u5408\u8c01<\/strong><\/td><\/tr><tr><td><strong>\u667a\u4eab AQ<\/strong><br>\u4e00\u4f53\u673a<\/td><td>RAS-80~160FSPUNAQ<br>\u5355\u76f8 220V\uff0c80 \/ 100 \/ 125 \/ 140 \/ 160 \u4e94\u6863<br>\uff083 \/ 3.5 \/ 4.5 \/ 5 \/ 6 \u5339\uff09<\/td><td>\u5185\u7f6e\u5728\u5916\u673a\u91cc\uff0c\u4e0d\u53e6\u9009\u6c34\u6a21\u5757<\/td><td>\u901a\u7528\u5185\u673a<\/td><td>\u6709\uff0c\u4f46\u4e0e\u5730\u6696\u4e8c\u9009\u4e00<\/td><td>90~160\u33a1\uff0c\u5916\u673a\u4f4d\u7d27\u5f20\uff0c\u7a7a\u8c03\u5730\u6696\u70ed\u6c34\u4e00\u673a\u89e3\u51b3<\/td><\/tr><tr><td><strong>\u667a\u4eab NQ<\/strong><br>\u4e00\u4f53\u673a<\/td><td>RAS-100~200FSPUNQ\uff08\u5355\u76f8 220V\uff0c\u516d\u6863\uff09<br>100 \/ 125 \/ 140 \/ 160 \/ 180 \/ 200<br>RAS-224\/240\/280\/320FSPUNYQ\uff08\u4e09\u76f8 380V\uff0c\u56db\u6863\uff09<\/td><td>\u5185\u7f6e\u5728\u5916\u673a\u91cc\uff0c\u4e0d\u53e6\u9009\u6c34\u6a21\u5757<\/td><td>\u901a\u7528\u5185\u673a<\/td><td>\u4e0d\u5e26\uff0c\u53e6\u914d\u70ed\u6c34\u5668<\/td><td>100~320\u33a1\uff0c\u51b7\u91cf\u8981\u5927\uff0c\u5ba4\u5185\u673a\u53f0\u6570\u591a<\/td><\/tr><tr><td><strong>\u5c0a\u777f\u5168\u6548\u2161<\/strong><br>\u5206\u4f53\u673a<\/td><td>RAS-125~335FSXPN5Q\/Y5Q<br>125 \/ 140 \/ 160 \/ 180 \/ 200 \/ 224<br>252 \/ 280 \/ 300 \/ 335<br>\u5171\u5341\u6863<\/td><td>\u5916\u7f6e\uff0cRWMG-160 \/ 224 \/ 280 \/ 335 \u5168\u6548\u6c34\u6a21\u5757\uff0c\u914d PC-WMH3Q \u63a7\u5236\u5668<\/td><td>\u4e09\u7ba1\u5236 FSVN2QB\/PC<\/td><td>\u53ef\u914d\u70ed\u6c34\u7bb1\u6210\u4e09\u8054\u4f9b<\/td><td>\u8981\u9664\u6e7f\u4e0d\u964d\u6e29\u3001\u6e29\u6e7f\u5206\u5f00\u63a7\uff1b\u5927\u5e73\u5c42\u3001\u5730\u4e0b\u5ba4\u3001\u6015\u6f6e<\/td><\/tr><tr><td><strong>\u5c0a\u777f\u522b\u5885<\/strong><br>\u5206\u4f53\u673a<\/td><td>RAS-504 \/ 560FSPNYZQA<\/td><td>\u5916\u7f6e\uff0cRWMG-160 \/ 200 \/ 280 \/ 335 \u4e24\u7ba1\u5236\u6c34\u6a21\u5757\uff0c\u53ef\u63a5 2~3 \u53f0\uff0c\u914d PC-WMH2Q \u63a7\u5236\u5668<\/td><td>\u4e24\u7ba1\u5236\u5185\u673a<\/td><td>\u6309\u9700<\/td><td>300\u33a1\u4ee5\u4e0a\u72ec\u680b\uff0c\u5c42\u6570\u591a\u3001\u7ba1\u8def\u957f\u3001\u672b\u7aef\u591a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>\u6c34\u6a21\u5757\u6709\u4e24\u6761\u7ebf\uff0c\u4e0d\u80fd\u4e92\u6362\u3002<\/strong>\u5168\u6548\u4e13\u7528\u7ebf\u662f 160 \/ 224 \/ 280 \/ 335\uff0c\u914d\u4e09\u7ba1\u5236\u5185\u673a\uff1b\u4e24\u7ba1\u5236\u7ebf\u662f 160 \/ 200 \/ 280 \/ 335\uff0c\u914d\u522b\u5885\u673a\uff0c\u4e5f\u914d VAM mini \u2161\u2014\u2014mini \u2161 \u5df2\u7ecf\u88c5\u4e86\u4e2d\u592e\u7a7a\u8c03\u3001\u518d\u60f3\u52a0\u5730\u6696\u7684\uff0c\u52a0\u7684\u5c31\u662f\u8fd9\u4e00\u6761\u4e24\u7ba1\u5236\u7ebf\u3002\u4e24\u6761\u7ebf\u578b\u53f7\u53ea\u5dee\u4e00\u4e2a\u5b57\u6bcd\uff0c\u7b7e\u5408\u540c\u524d\u5fc5\u987b\u628a\u5916\u673a\u578b\u53f7\u548c\u6c34\u6a21\u5757\u578b\u53f7\u5e76\u6392\u6838\u5bf9\u4e00\u6b21\u3002<\/p>\n\n<p>\u56db\u6761\u91cc\u524d\u4e24\u6761\u662f\u667a\u4eab\uff0c\u4e0b\u9762 4.1 \u5230 4.4 \u9010\u6761\u8bb2\u3002\u5168\u6548\u2161 \u548c\u522b\u5885\u90a3\u4e24\u6761\u600e\u4e48\u914d\u3001\u56db\u6761\u8def\u600e\u4e48\u4e00\u773c\u5206\u5f00\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\uff1b\u56db\u6761\u8def\u4e3a\u4ec0\u4e48\u8fd9\u4e48\u5206\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b\u6280\u672f\u624b\u518c<\/a>\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4.1 AQ vs NQ \u6838\u5fc3\u5bf9\u6bd4<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>AQ\uff08\u5929\u6c1f\u70ed\u6c34\u4e00\u4f53\u673a\uff09<br>RAS-80~160FSPUNAQ<\/th><th>NQ\uff08\u5929\u6c1f\u5730\u6c34\u4e00\u4f53\u673a\uff09<br>RAS-100~200FSPUNQ<br>RAS-224\/240\/280\/320FSPUNYQ<\/th><\/tr><\/thead><tbody>\n<tr><td>\u4ea7\u54c1\u5168\u79f0<\/td><td>\u6574\u4f53\u5f0f\u5929\u6c1f\u70ed\u6c34\uff0f\u5730\u6c34<\/td><td>\u5929\u6c1f\u5730\u6c34\uff0c\u6c34\u6a21\u5757\u5185\u7f6e<\/td><\/tr>\n<tr><td>\u7cfb\u7edf\u5f62\u5f0f<\/td><td>\u4e00\u4f53\u5f0f\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc<\/td><td>\u4e00\u4f53\u5f0f\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc<\/td><\/tr>\n<tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u6709\uff0c\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\uff0c\u540c\u4e00\u65f6\u95f4\u53ea\u80fd\u8d70\u4e00\u4e2a\u529f\u80fd<\/td><td>\u4e0d\u652f\u6301\uff0c\u70ed\u6c34\u53e6\u914d\u70ed\u6c34\u5668<\/td><\/tr>\n<tr><td>\u5916\u673a\u98ce\u6247<\/td><td>\u5355\u98ce\u6247<\/td><td>\u5355\u98ce\u6247\uff0f\u53cc\u98ce\u6247\uff0c\u6309\u578b\u53f7<\/td><\/tr>\n<tr><td>\u7535\u6e90<\/td><td>\u5168\u7cfb 220V \u5355\u76f8<\/td><td>100~200 \u578b\uff1a220V \u5355\u76f8<br>224~320 \u578b\uff1a380V \u4e09\u76f8<\/td><\/tr>\n<tr><td>\u51b7\u91cf\u8303\u56f4<\/td><td>8.0\uff5e15.5kW\uff0880~160 \u578b\uff09<\/td><td>10.0\uff5e32.0kW\uff08100~320 \u578b\uff09<\/td><\/tr>\n<tr><td>\u5339\u6570\uff0f\u9002\u7528\u9762\u79ef<\/td><td>3\uff5e6 \u5339\uff0c\u7ea6 90\uff5e160\u33a1<\/td><td>4\uff5e12 \u5339\uff0c\u7ea6 100\uff5e320\u33a1<\/td><\/tr>\n<tr><td>\u8fde\u63a5\u7387\u533a\u95f4<\/td><td>50%~130%<\/td><td>50%~150%<\/td><\/tr>\n<tr><td>\u538b\u7f29\u673a<\/td><td>\u76f4\u6d41\u53d8\u9891\u53cc\u8f6c\u5b50<\/td><td>\u8865\u6c14\u589e\u7113\u53cc\u8f6c\u5b50\uff08100~160 \u578b\uff09<br>\u8865\u6c14\u589e\u7113\u6da1\u65cb\uff08180~320 \u578b\uff09<\/td><\/tr>\n<tr><td>APF \u6700\u9ad8<\/td><td>6.15\uff0880\uff0f100 \u578b\uff09<\/td><td>\u7ea6 5.3\uff5e5.8\uff0c\u578b\u53f7\u8d8a\u5927\u8d8a\u4f4e<\/td><\/tr>\n<tr><td>\u5730\u6696\u529f\u80fd<\/td><td>\u652f\u6301<\/td><td>\u652f\u6301\uff0c\u6c34\u6a21\u5757\u5185\u7f6e<\/td><\/tr>\n<tr><td>\u4e3b\u8981\u5356\u70b9<\/td><td>\u7a7a\u95f4\u96c6\u6210\uff0c\u5e26\u70ed\u6c34\uff0c\u5c0f\u6237\u578b\u9996\u9009<\/td><td>\u51b7\u91cf\u5927\uff0c\u53ef\u5e26\u66f4\u591a\u5ba4\u5185\u673a\uff0c\u4e2d\u5927\u6237\u578b<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e24\u4e2a\u90fd\u662f\u4e00\u4f53\u673a\uff0c\u533a\u522b\u53ea\u6709\u4e00\u4e2a\u3002<\/strong>AQ \u548c NQ \u7684\u6c34\u6a21\u5757\u90fd\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u9762\uff0c\u51fa\u5382\u914d\u597d\uff0c\u7b7e\u5355\u65f6\u4e0d\u9700\u8981\u518d\u9009\u6c34\u6a21\u5757\uff0c\u4e5f\u4e0d\u5b58\u5728\u5916\u7f6e\u6c34\u6a21\u5757\u8fd9\u4e2a\u9009\u9879\u3002\u771f\u6b63\u7684\u533a\u522b\u662f\u751f\u6d3b\u70ed\u6c34\uff1aAQ \u5e26\uff0cNQ \u4e0d\u5e26\u3002\u5bb6\u91cc\u5df2\u7ecf\u6709\u70ed\u6c34\u5668\u3001\u6216\u8005\u6253\u7b97\u53e6\u5916\u4e70\u7684\uff0c\u9009 NQ \u66f4\u5212\u7b97\uff1b\u5916\u673a\u4f4d\u53ea\u591f\u653e\u4e00\u53f0\u3001\u53c8\u60f3\u8fde\u70ed\u6c34\u4e00\u8d77\u89e3\u51b3\u7684\uff0c\u9009 AQ\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">NQ \u7684\u53e6\u4e00\u4e2a\u4f18\u52bf\u5728\u51b7\u91cf\u3002100~200 \u578b\u8d70 220V \u5355\u76f8\uff0c224~320 \u578b\u8d70 380V \u4e09\u76f8\uff0c\u6700\u5927\u5e26 12 \u5339\uff0c\u5ba4\u5185\u673a\u53f0\u6570\u591a\u7684\u5927\u5e73\u5c42\u7528\u5f97\u4e0a\u8fd9\u4e00\u6863\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8fde\u63a5\u7387\u8fd9\u4e00\u680f\uff1a<strong>AQ \u5230 130%\uff0cNQ \u5230 150%<\/strong>\uff0c\u4e24\u4e2a\u4e0a\u9650\u4e0d\u4e00\u6837\u3002\u8fd9\u662f\u4e0a\u9650\uff0c\u4e0d\u662f\u63a8\u8350\u503c\u2014\u2014NQ \u7684 150% \u80fd\u7528\u7684\u524d\u63d0\u662f\u5ba4\u5185\u673a\u4e0d\u540c\u65f6\u5168\u5f00\uff1a\u7a7a\u8c03\u540c\u5f00\u7387\u52a0\u4e0a\u5730\u6696\u8d1f\u8377\uff0c\u4e24\u9879\u5408\u8ba1\u5728\u5ba4\u5916\u673a 66% \u4ee5\u5185\uff0c1.5 \u500d\u8d85\u914d\u624d\u5403\u5f97\u4e0b\u3002\u5177\u4f53\u5230\u67d0\u4e00\u53f0\u673a\u5668\uff0c\u8fd8\u8981\u6309\u65e5\u7acb\u8bbe\u8ba1\u624b\u518c\u590d\u6838\u4e00\u6b21\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u9009\u62e9\u903b\u8f91\uff1a<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9700\u6c42\u573a\u666f<\/th><th>\u63a8\u8350\u65b9\u6848<\/th><th>\u7406\u7531<\/th><\/tr><\/thead><tbody>\n<tr><td>\u5c0f\u6237\u578b 90~120\u33a1\uff0c\u5916\u673a\u4f4d\u7d27\u5f20\uff0c\u9700\u8981\u751f\u6d3b\u70ed\u6c34<\/td><td><strong>AQ\uff08\u5929\u6c1f\u70ed\u6c34\u4e00\u4f53\u673a\uff09<\/strong><\/td><td>\u88c5\u4e00\u53f0\u89e3\u51b3\u7a7a\u8c03\u3001\u5730\u6696\u3001\u70ed\u6c34\u4e09\u4ef6\u4e8b\uff0c\u4e0d\u5360\u7b2c\u4e8c\u4e2a\u5916\u673a\u4f4d<\/td><\/tr>\n<tr><td>\u4e2d\u5927\u6237\u578b 160~320\u33a1\uff0c\u51b7\u91cf\u8981\u5927\uff0c\u5ba4\u5185\u673a\u53f0\u6570\u591a\uff0c\u5bb6\u91cc\u53e6\u914d\u70ed\u6c34\u5668<\/td><td><strong>NQ\uff08\u4e00\u4f53\u5316\u4e3b\u673a \uff0b \u72ec\u7acb\u70ed\u6c34\u5668\uff0f\u70ed\u6c34\u7bb1\uff09<\/strong><\/td><td>\u51b7\u91cf\u4e0a\u9650\u5230 12 \u5339\uff0c\u53ef\u5e26\u66f4\u591a\u5ba4\u5185\u673a\uff1b\u70ed\u6c34\u4ea4\u7ed9\u72ec\u7acb\u8bbe\u5907\uff0c\u4e92\u4e0d\u5f71\u54cd<\/td><\/tr>\n<tr><td>\u9884\u7b97\u6709\u9650\uff0c\u53ea\u8981\u51b7\u6696\uff0c\u4e0d\u8003\u8651\u751f\u6d3b\u70ed\u6c34<\/td><td><strong>NQ\uff08\u4e00\u4f53\u5316\u4e3b\u673a\uff09<\/strong><\/td><td>\u529f\u80fd\u805a\u7126\uff0c\u521d\u6295\u8d44\u66f4\u4f4e<\/td><\/tr>\n<tr><td>\u5df2\u6709\u70ed\u6c34\u5668\uff0c\u60f3\u63d0\u5347\u5c40\u90e8\u70ed\u6c34\u4f53\u9a8c<\/td><td><strong>NQ \uff0b \u5c0f\u53a8\u5b9d\uff0f\u745e\u5c0f\u767d<\/strong><\/td><td>\u73b0\u6709\u70ed\u6c34\u5668\u52a0\u5c40\u90e8\u8865\u70ed\uff0c\u7ecf\u6d4e\u5b9e\u7528<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u9700\u8981\u5916\u7f6e\u6c34\u6a21\u5757\u7684\u662f\u53e6\u5916\u4e24\u6761\u7ebf\uff1a\u5c0a\u777f\u5168\u6548\u2161 \u914d RWMG-160\/224\/280\/335FWXNZQ\uff0c\u5c0a\u777f\u522b\u5885\u914d RWMG-160\/200\/280\/335FWNZ1Q\u3002\u8fd9\u4e24\u6761\u7ebf\u624d\u6709\u72ec\u7acb\u7684\u6c1f\u6c34\u6362\u70ed\u5668\u3002\u5b83\u4eec\u600e\u4e48\u914d\u3001\u8ddf\u667a\u4eab\u6bd4\u5dee\u5728\u54ea\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4.1.1 \u667a\u4eab\u4e0d\u53e6\u914d\u6c34\u6a21\u5757<\/h3>\n\n<p class=\"wp-block-paragraph\">AQ \u548c NQ \u90fd\u662f<strong>\u4e00\u4f53\u673a<\/strong>\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u9762\uff0c\u51fa\u5382\u5c31\u914d\u597d\uff0c\u7b7e\u5355\u65f6\u4e0d\u9700\u8981\u518d\u9009\u6c34\u6a21\u5757\uff0c\u4e5f\u4e0d\u5b58\u5728\u5916\u7f6e\u6c34\u6a21\u5757\u8fd9\u4e2a\u9009\u9879\u3002\u4e24\u6761\u7684\u533a\u522b\u53ea\u6709\u4e00\u6761\uff1aAQ \u80fd\u51fa\u751f\u6d3b\u70ed\u6c34\uff0c\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\uff1bNQ \u6ca1\u6709\u8fd9\u4e00\u9879\uff0c\u70ed\u6c34\u53e6\u914d\u70ed\u6c34\u5668\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u9700\u8981\u5916\u7f6e\u6c34\u6a21\u5757\u7684\u662f\u53e6\u5916\u4e24\u6761\u7ebf\uff1a\u5c0a\u777f\u5168\u6548\u2161 \u914d <strong>RWMG-160\/224\/280\/335FWXNZQ<\/strong>\uff0c\u5c0a\u777f\u522b\u5885\u914d <strong>RWMG-160\/200\/280\/335FWNZ1Q<\/strong>\u3002\u4e24\u6761\u7ebf\u53ea\u5dee\u4e00\u4f4d\u6570\u5b57\uff0c\u6863\u4f4d\u4e5f\u4e0d\u4e00\u6837\uff0c\u914d\u9519\u4e86\u673a\u5668\u88c5\u4e0d\u4e0a\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4.2 \u5ba4\u5185\u673a\u9002\u914d\u77e9\u9635\uff08\u542b\u6838\u5fc3\u53c2\u6570\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5ba4\u5185\u673a\u7c7b\u578b<\/th><th>\u578b\u53f7\u7cfb\u5217<\/th><th>\u529f\u80fd\u4fa7\u91cd<\/th><th>\u51b7\u91cf(kW)<\/th><th>\u98ce\u91cf(m\u00b3\/h)<\/th><th>\u566a\u97f3dB(A)<\/th><th>\u673a\u5916\u9759\u538b(Pa)<\/th><th>\u5c3a\u5bf8H\u00d7W\u00d7D(mm)<\/th><th>\u63a8\u8350\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td>\u8d85\u4f4e\u9759\u97f3\u578b<\/td><td>RPIZ-S<\/td><td>\u6781\u81f4\u9759\u97f3<\/td><td>2.0-7.1<\/td><td>250-1000<\/td><td>22-35<\/td><td>10-30<\/td><td>200\u00d7900\u00d7450<\/td><td>\u5367\u5ba4\u3001\u4e66\u623f<\/td><\/tr><tr><td>PE\u51c0\u5316\u578b<\/td><td>RPIZ-PE<\/td><td>PM2.5\/\u7532\u919b\/\u75c5\u6bd2\u51c0\u5316<\/td><td>2.0-7.1<\/td><td>250-1000<\/td><td>22-36<\/td><td>10-30<\/td><td>200\u00d7900\u00d7450<\/td><td>\u5168\u5c4b\uff0c\u8fc7\u654f\u4f53\u8d28\u5bb6\u5ead<\/td><\/tr><tr><td>\u6807\u51c6\u98ce\u7ba1\u5f0f<\/td><td>RPIZ<\/td><td>\u57fa\u7840\u5236\u51b7\u5236\u70ed<\/td><td>2.0-7.1<\/td><td>300-1200<\/td><td>25-38<\/td><td>15-40<\/td><td>200\u00d7880\u00d7440<\/td><td>\u5ba2\u9910\u5385\u7b49\u5927\u7a7a\u95f4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"background:#F0F7F4;border-left:4px solid #2E7D5B;padding:14px 18px;margin:18px 0;font-size:14.5px;line-height:1.9;\">\n<p><b>\u65e5\u7acb\u4e09\u7ba1\u5236\"\u8212\u723d\u6a21\u5f0f\"\uff1a\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u8fd8\u80fd\u5347\u6e29\uff08\u5b98\u65b9\u6570\u636e\uff09<\/b><\/p>\n<p>\u8212\u723d\u6a21\u5f0f\u6ca1\u6709\u56fa\u5b9a\u51fa\u98ce\u6e29\u5ea6\uff0c\u968f\u5b50\u6a21\u5f0f\u52a8\u6001\u8c03\u8282\u3002\u6e29\u5ea6\u8bbe\u5b9a 16\uff5e32\u2103\uff08\u00b10.5\u2103\uff09\uff0c\u6e7f\u5ea6\u8bbe\u5b9a 35%\uff5e90%\uff0856 \u6863\u53ef\u8c03\uff09\uff1a<\/p>\n<p>\u2460 <b>\u964d\u6e29\u9664\u6e7f<\/b>\uff08\u6851\u62ff\u5929\u9ad8\u6e29\u9ad8\u6e7f\uff09\uff1a\u5236\u51b7\uff0b\u9664\u6e7f\uff0c\u51fa\u98ce\u8f83\u4f4e\uff08\u7ea6 12\uff5e18\u2103\uff09\uff1b<br>\n\u2461 <b>\u4e0d\u964d\u6e29\u9664\u6e7f<\/b>\uff08\u6885\u96e8\u5b63\/\u56de\u5357\u5929\uff09\uff1a\u9664\u6e7f\u540e\u56de\u6536\u4f59\u70ed\u518d\u70ed\uff0c\u51fa\u98ce\u7ea6 24\uff5e26\u2103\uff0c\u63a5\u8fd1\u5ba4\u6e29\uff0c\u9664\u6e7f\u4e0d\u964d\u6e29\uff1b<br>\n\u2462 <b>\u5347\u6e29\u9664\u6e7f<\/b>\uff08\u51ac\u5b63\u6e7f\u51b7\/\u5730\u4e0b\u5ba4\uff09\uff1a\u4e00\u7247\u6362\u70ed\u5668\u5236\u51b7\u9664\u6e7f\u3001\u53e6\u4e00\u7247\u5f3a\u529b\u5236\u70ed\u5347\u6e29\uff0c\u518d\u70ed\u540e\u6700\u9ad8\u51fa\u98ce\u6e29\u5ea6\u53ef\u8fbe 32\u2103\uff1b\u5b98\u65b9\u5b9e\u6d4b\uff1a\u6e29\u5ea6 15\u2103\u219225\u2103\u3001\u6e7f\u5ea6 85%\u219246%\uff0c\u4ece\u53c8\u51b7\u53c8\u6f6e\u5230\u6e29\u6696\u53c8\u8212\u723d\u3002<\/p>\n<p>\u53e6\u6709<b>\u67d4\u6da6\u5236\u51b7<\/b>\uff1a\u5f53\u5ba4\u6e29\u63a5\u8fd1\u8bbe\u5b9a\u6e29\u5ea6\uff08\u22644\u2103\uff09\u65f6\u81ea\u52a8\u63d0\u9ad8\u51fa\u98ce\u6e29\u5ea6\u5230\u7ea6 18\u2103 \u67d4\u98ce\uff08\u666e\u901a\u7a7a\u8c03\u7ea6\u55b7 12\u2103 \u51b0\u78b4\u5b50\u98ce\uff0c\u9ad8\u51fa\u8fd1 6\u2103\uff09\uff0c\u6e7f\u5ea6\u4fdd\u6301\u5728 40%\uff5e60%\uff0c\u4e0d\u8fc7\u5ea6\u9664\u6e7f\u3002<\/p>\n<p><b>\u8bf4\u660e<\/b>\uff1a\u65e5\u7acb\u667a\u4eab\u4e0d\u80fd\u642d\u914d\u4e09\u7ba1\u5236\u5185\u673a\uff0c\u82e5\u9700\u8981\u6e29\u5ba4\u5e73\u8861\u6216\u8212\u723d\u70ed\u56de\u6536\u6a21\u5f0f\uff0c\u5929\u6c1f\u5730\u6c34\u9700\u7528\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u5916\u7f6e\u6c34\u6a21\u5757\uff0c\u642d\u914d\u4e09\u7ba1\u5236\u5185\u673a\u5b9e\u73b0\u3002<\/p>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u53c2\u6570\u8bf4\u660e<\/strong>\uff1a\u98ce\u91cf\u548c\u9759\u538b\u56e0\u5177\u4f53\u578b\u53f7\uff08\u59822.0kW vs 7.1kW\uff09\u5dee\u5f02\u8f83\u5927\uff0c\u8868\u4e2d\u4e3a\u8be5\u7cfb\u5217\u8986\u76d6\u8303\u56f4\u3002\u5177\u4f53\u578b\u53f7\u7684\u7cbe\u786e\u6570\u636e\u4ee5\u65e5\u7acb\u5b98\u65b9\u5ba4\u5185\u673a\u6837\u672c\u4e3a\u51c6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PE\u51c0\u5316\u578b vs \u6807\u51c6\u578b<\/strong>\uff1aPE\u51c0\u5316\u578b\u6807\u914dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff0cPM2.5\u53bb\u9664\u738794.46%\uff0cH3N2\u6d41\u611f\u75c5\u6bd2\u53bb\u9664\u738796.85%\uff0c\u7532\u919b\u53bb\u9664\u738774.90%\u3002\u6807\u51c6\u578b\u53d6\u6d88PE\u6a21\u5757\u548c\u6e7f\u5ea6\u4f20\u611f\u5668\uff0c\u4f46\u4fdd\u7559\u667a\u80fd\u81ea\u6e05\u6d01\u548c60\u2103\u9ad8\u6e29\u9664\u83cc\uff0c\u662f\u6027\u4ef7\u6bd4\u4e4b\u9009\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">4.3 \u4e94\u6052\u7cfb\u7edf\u5347\u7ea7\u8def\u5f84\uff08\u5168\u5c4b\u5168\u611f2.0\/3.0\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u53ef\u4f5c\u4e3a\"\u4e94\u6052\u57fa\u5ea7\"\uff0c\u62d3\u5c55\u4e3a\u5b8c\u6574\u4e94\u6052\u7cfb\u7edf\uff1a<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>\u667a\u4eab\u4e3b\u673a\uff08\u5929\u6c1f\u5730\u6c34\u5e95\u5ea7\uff09\n    \u251c\u2500\u2500 \u5929\u51c0Q7\u65b0\u98ce\u7cfb\u7edf\uff1a\u5168\u70ed\u4ea4\u6362\uff0cPM2.5\u8fc7\u6ee4\uff0c\u5168\u5c4b\u6362\u6c14\n    \u251c\u2500\u2500 \u6e29\u6e7f\u53cc\u63a7\u5185\u673a\uff1a\u6052\u6e29+\u6052\u6e7f\uff0856\u6863\u7cbe\u51c6\u63a7\u6e7f\uff09\n    \u251c\u2500\u2500 PE\u51c0\u5316\u6a21\u5757\uff1a\u7a7a\u6c14\u51c0\u5316\uff08PM2.5\/\u7532\u919b\/\u75c5\u6bd2\uff09\n    \u251c\u2500\u2500 \u963f\u5c14\u838e\u5a1c\u5168\u5c4b\u8f6f\u6c34\uff1a\u5168\u5c4b\u751f\u6d3b\u7528\u6c34\u8f6f\u5316\n    \u251c\u2500\u2500 \u745e\u7f8e\u70ed\u6c34\u7cfb\u7edf\uff1a\u5927\u5bb9\u91cf\u6052\u6e29\u70ed\u6c34\n    \u2514\u2500\u2500 \u5c0f\u7acb\u7a7a\u6c14\u7ba1\u5bb6\uff1a\u4f20\u611f\u5668+\u667a\u80fd\u8054\u52a8<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e94\u6052\u7cfb\u7edf\u8054\u52a8\u8bbe\u5907\u578b\u53f7\u6e05\u5355<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4e94\u6052\u7ef4\u5ea6<\/th><th>\u8bbe\u5907\u540d\u79f0<\/th><th>\u578b\u53f7\u53c2\u8003<\/th><th>\u529f\u80fd<\/th><\/tr><\/thead><tbody><tr><td>\u6052\u6e29<\/td><td>\u667a\u4eab\u4e3b\u673a\uff08AQ\/NQ\uff09<\/td><td>RAS-80~160FSPUNAQ \uff0f RAS-100~200FSPUNQ \uff0f RAS-224~320FSPUNYQ<\/td><td>\u7a7a\u8c03\u5236\u51b7+\u5730\u6696\u91c7\u6696<\/td><\/tr><tr><td>\u6052\u6e29<\/td><td>\u5916\u7f6e\u6c34\u6a21\u5757\uff08\u4ec5\u5168\u6548\u914d\u5957\uff09<\/td><td>RWMG-160\/224\/280\/335FWXNZQ<\/td><td>\u6c1f\u6c34\u6362\u70ed\uff0c\u9a71\u52a8\u5730\u6696\uff1b\u667a\u4eab AQ\uff0fNQ \u6c34\u6a21\u5757\u5185\u7f6e\uff0c\u4e0d\u9700\u8981\u53e6\u914d<\/td><\/tr><tr><td>\u6052\u6e7f<\/td><td>\u6e29\u6e7f\u53cc\u63a7\u5185\u673a<\/td><td>RPIZ-TH\u7cfb\u5217<\/td><td>\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c56\u6863\u63a7\u6e7f<\/td><\/tr><tr><td>\u6052\u6c27<\/td><td>\u65e5\u7acb\u5929\u51c0Q7\u9664\u6e7f\u65b0\u98ce<\/td><td>KPI-2521Q7\/FH\uff08250m\u00b3\/h\uff09<\/td><td>\u5168\u70ed\u4ea4\u6362\u65b0\u98ce+\u9664\u6e7f\uff0c\u65b0\u98ce\u91cf150-500m\u00b3\/h<\/td><\/tr><tr><td>\u6052\u6d01<\/td><td>PE\u51c0\u5316\u6a21\u5757<\/td><td>\u667a\u4eab\u6807\u914d\/\u9009\u914d<\/td><td>PM2.5\/\u7532\u919b\/\u75c5\u6bd2\u53bb\u9664<\/td><\/tr><tr><td>\u6052\u6d01<\/td><td>\u963f\u5c14\u838e\u5a1c\u5168\u5c4b\u8f6f\u6c34<\/td><td>ASC-CTO\/ASC-RO\u7cfb\u5217<\/td><td>\u5168\u5c4b\u751f\u6d3b\u7528\u6c34\u8f6f\u5316\uff0c\u672b\u7aefRO\u76f4\u996e<\/td><\/tr><tr><td>\u6052\u6d01<\/td><td>\u745e\u7f8e\u70ed\u6c34\u7cfb\u7edf<\/td><td>AHR-200L\/300L\u50a8\u70ed\u6c34\u7bb1<\/td><td>\u5927\u5bb9\u91cf\u6052\u6e29\u70ed\u6c34\uff0c\u72ec\u7acb\u4e8e\u7a7a\u8c03\u7cfb\u7edf<\/td><\/tr><tr><td>\u6052\u9759<\/td><td>\u8d85\u4f4e\u9759\u97f3\u5185\u673a<\/td><td>RPIZ-S\u7cfb\u5217<\/td><td>\u6700\u4f4e22dB\u8fd0\u884c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u573a\u666f\u8054\u52a8\u793a\u4f8b<\/strong>\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u573a\u666f\u6a21\u5f0f<\/th><th>\u7a7a\u8c03<\/th><th>\u5730\u6696<\/th><th>\u65b0\u98ce<\/th><th>\u9664\u6e7f<\/th><th>\u51c0\u5316<\/th><\/tr><\/thead><tbody><tr><td>\u7761\u7720\u6a21\u5f0f<\/td><td>26\u2103\u9759\u97f3<\/td><td>\u5173\u95ed<\/td><td>\u4f4e\u6863<\/td><td>\u81ea\u52a8<\/td><td>\u81ea\u52a8<\/td><\/tr><tr><td>\u513f\u7ae5\u623f\u6a21\u5f0f<\/td><td>24\u2103\u9632\u76f4\u5439<\/td><td>\u51ac\u5b6335\u2103<\/td><td>\u4e2d\u6863<\/td><td>\u5173\u95ed<\/td><td>\u5e38\u5f00<\/td><\/tr><tr><td>\u79bb\u5bb6\u6a21\u5f0f<\/td><td>\u5173\u95ed<\/td><td>\u9632\u51bb8\u2103<\/td><td>\u5173\u95ed<\/td><td>\u5173\u95ed<\/td><td>\u5173\u95ed<\/td><\/tr><tr><td>\u56de\u5bb6\u6a21\u5f0f<\/td><td>\u5feb\u901f\u964d\u6e29\/\u5347\u6e29<\/td><td>\u6b63\u5e38<\/td><td>\u81ea\u52a8<\/td><td>\u81ea\u52a8<\/td><td>\u81ea\u52a8<\/td><\/tr><tr><td>\u6885\u96e8\u5b63\u6a21\u5f0f<\/td><td>\u4e0d\u964d\u6e29\u9664\u6e7f<\/td><td>\u5173\u95ed<\/td><td>\u4f4e\u6863<\/td><td>\u5f3a\u529b<\/td><td>\u5e38\u5f00<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4e0e\u5168\u7a7a\u6c14\u7cfb\u7edf\u76f8\u6bd4\u66f4\u7701\u7535\uff0c\u4e0e\u7eaf\u6c34\u7cfb\u7edf\u76f8\u6bd4\u54cd\u5e94\u66f4\u5feb\uff0c\u662f\"\u6c1f\u673a\u4e94\u6052\"\u7684\u5178\u578b\u4ee3\u8868\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">4.4 \u5168\u5c4b\u5168\u611f 2.0 vs 3.0 \u529f\u80fd\u5bf9\u6bd4<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u5168\u5c4b\u5168\u611f 2.0\uff082023\u5e74\uff09<\/th><th>\u5168\u5c4b\u5168\u611f 3.0\uff082025\u5e74\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u6838\u5fc3\u5347\u7ea7<\/td><td>\u667a\u4eab\u63a5\u5165\u4e94\u6052\u7cfb\u7edf\uff0c\u573a\u666f\u8054\u52a8<\/td><td>\u63a5\u5165AI\u667a\u63a7\uff0c\u81ea\u4e3b\u5b66\u4e60\u7528\u6237\u4e60\u60ef<\/td><\/tr><tr><td>\u63a7\u5236\u65b9\u5f0f<\/td><td>\u5c0f\u7acb\u667a\u5bb6APP + 5G\u7269\u8054<\/td><td>APP + AI\u8bed\u97f3 + 5G + OTA\u8fdc\u7a0b\u5347\u7ea7<\/td><\/tr><tr><td>\u667a\u80fd\u5316\u7a0b\u5ea6<\/td><td>\u56fa\u5b9a\u573a\u666f\u6a21\u5f0f\u5207\u6362<\/td><td>AI\u81ea\u4e3b\u5b66\u4e60\uff0c\u81ea\u52a8\u4f18\u5316\u8fd0\u884c\u7b56\u7565<\/td><\/tr><tr><td>\u8054\u52a8\u8303\u56f4<\/td><td>\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce+\u9664\u6e7f+\u51c0\u5316<\/td><td>\u540c\u4e0a+\u8f6f\u6c34+\u70ed\u6c34\u5668+\u667a\u80fd\u7a97\u5e18+\u706f\u5149<\/td><\/tr><tr><td>\u6570\u636e\u80fd\u529b<\/td><td>\u57fa\u7840\u80fd\u8017\u7edf\u8ba1<\/td><td>\u80fd\u8017\u5206\u6790\u62a5\u544a+\u5f02\u5e38\u9884\u8b66+\u8282\u80fd\u5efa\u8bae<\/td><\/tr><tr><td>\u9002\u7528\u4ea7\u54c1<\/td><td>\u7b2c\u4e09\u4ee3\u667a\u4eab\u5168\u7cfb<\/td><td>\u7b2c\u4e09\u4ee3\u667a\u4eab\u5168\u7cfb\uff08OTA\u5347\u7ea7\u5373\u53ef\uff09<\/td><\/tr><tr><td>\u5347\u7ea7\u6210\u672c<\/td><td>\u65b0\u8d2d\u8bbe\u5907\u5373\u53ef<\/td><td>\u8001\u7528\u6237\u53ef\u901a\u8fc7OTA\u5347\u7ea7\u90e8\u5206\u529f\u80fd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u603b\u7ed3<\/strong>\uff1a2.0\u89e3\u51b3\"\u80fd\u8054\u52a8\"\uff0c3.0\u89e3\u51b3\"\u4f1a\u601d\u8003\"\u3002\u5df2\u5b89\u88c52.0\u7684\u7528\u6237\u53ef\u901a\u8fc7\u56fa\u4ef6\u5347\u7ea7\u83b7\u5f97\u90e8\u52063.0\u529f\u80fd\u3002<\/p>\n<\/blockquote>\n\n\n\n<p><strong>\u667a\u4eab\u505a\u4e0d\u5230\u7684\u4e00\u4ef6\u4e8b\uff0c\u5f97\u8bf4\u6e05\u695a\uff1a\u5b83\u7684\u5ba4\u5185\u673a\u53ea\u80fd\u914d\u901a\u7528\u578b\uff0c\u914d\u4e0d\u4e86\u4e09\u7ba1\u5236\u3002<\/strong>\u4e09\u7ba1\u5236\u5185\u673a\u6bd4\u666e\u901a\u5185\u673a\u591a\u4e00\u6839\u9ad8\u4f4e\u538b\u6c14\u7ba1\uff0c\u9664\u6e7f\u65f6\u5148\u628a\u62bd\u8d70\u7684\u51b7\u91cf\u5b58\u4f4f\uff0c\u6e7f\u5ea6\u964d\u4e0b\u6765\u518d\u8fd8\u56de\u623f\u95f4\uff0c\u6240\u4ee5\u80fd\u505a\u5230\u9664\u6e7f\u4e0d\u964d\u6e29\u3002\u4f46\u8fd9\u6839\u7ba1\u5b50\u7684\u901a\u8baf\u534f\u8bae\u8ddf\u667a\u4eab\u5916\u673a\u5bf9\u4e0d\u4e0a\uff0c\u786c\u63a5\u4e0d\u5de5\u4f5c\u3002<\/p>\n\n<p>\u8981\u505a\u6e29\u6e7f\u5206\u5f00\u63a7\uff0c\u53ea\u80fd\u6362\u5c0a\u777f\u5168\u6548\u2161 \u5916\u673a\uff0c\u518d\u914d\u4e00\u4e2a\u5916\u7f6e\u6c34\u6a21\u5757\u5e26\u5730\u6696\u2014\u2014\u8fd9\u5c31\u662f\u5168\u6548\u4e24\u8054\u4f9b\u3002\u5b83\u4e0d\u662f\u667a\u4eab\u7684\u5347\u7ea7\u7248\uff0c\u662f\u53e6\u4e00\u6761\u8def\uff1a\u5916\u673a\u3001\u6c34\u6a21\u5757\u3001\u5185\u673a\u4e09\u6837\u90fd\u4e0d\u4e00\u6837\u3002\u5168\u6548\u4e24\u8054\u4f9b\u80fd\u914d\u4e09\u7ba1\u5236\u3001\u80fd\u52a0\u70ed\u6c34\u7bb1\u505a\u4e09\u8054\u4f9b\uff0c\u4f46\u5b83\u662f\u5206\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u8981\u5355\u72ec\u627e\u4f4d\u7f6e\u653e\u3002<\/p>\n\n<p>\u5168\u6548\u2161 \u548c\u522b\u5885\u673a\u600e\u4e48\u914d\u3001\u8ddf\u667a\u4eab\u6bd4\u5dee\u5728\u54ea\u3001\u4ec0\u4e48\u623f\u5b50\u8be5\u8d70\u90a3\u4e24\u6761\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 \u667a\u4eab\u3001\u5168\u6548\u3001\u522b\u5885\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\u3002\u5355\u770b\u5168\u6548\u8fd9\u4e00\u53f0\u673a\u5668\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161 \u4ea7\u54c1\u8be6\u60c5<\/a>\u3002<\/p>\n\n<h2 id=\"rlzx05\" class=\"wp-block-heading\">\u7b2c\u4e94\u7ae0\uff1a\u667a\u4eab\u7684\u9884\u7b97\u4e0e\u901f\u67e5<\/h2>\n\n\n\n<p>\u8fd9\u4e00\u7ae0\u53ea\u8bb2\u667a\u4eab\u81ea\u5df1\u7684\u4e24\u6761\u7ebf\u600e\u4e48\u5b9a\u6863\u4f4d\u3001\u5927\u6982\u4ec0\u4e48\u9884\u7b97\u3002<strong>\u8981\u662f\u8fd8\u6ca1\u5b9a\u8d70\u667a\u4eab\u3001\u5168\u6548\u8fd8\u662f\u522b\u5885\uff0c\u5148\u770b\u90a3\u4e00\u9875\uff1a<\/strong><a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 \u667a\u4eab\u3001\u5168\u6548\u3001\u522b\u5885\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\u2014\u2014\u56db\u6761\u914d\u6cd5\u7684\u578b\u53f7\u3001\u8d85\u914d\u7387\u3001\u54ea\u4e9b\u623f\u5b50\u4e0d\u63a8\u8350\uff0c\u90fd\u5728\u90a3\u91cc\u6446\u5f00\u4e86\u6bd4\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">5.2 \u9884\u7b97\u53c2\u8003\uff08\u542b\u5b89\u88c5\uff0c2025\u5e74\u5e02\u573a\u53c2\u8003\u4ef7\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6237\u578b\u9762\u79ef<\/th><th>\u63a8\u8350\u914d\u7f6e<\/th><th>\u9884\u7b97\u8303\u56f4\uff08\u4e07\u5143\uff09<\/th><th>\u5e74\u5747\u8fd0\u884c\u8d39\uff08\u5143\uff09<\/th><\/tr><\/thead><tbody><tr><td>90-110\u33a1<\/td><td>AQ 80\/100\u578b + 3-4\u53f0\u5185\u673a<\/td><td>2.8-3.5<\/td><td>2,200-3,000<\/td><\/tr><tr><td>110-140\u33a1<\/td><td>AQ\/NQ 125-140\u578b + 4-5\u53f0\u5185\u673a<\/td><td>3.2-4.0<\/td><td>2,800-3,600<\/td><\/tr><tr><td>140-180\u33a1<\/td><td>NQ 160-180\u578b + 5-6\u53f0\u5185\u673a<\/td><td>3.8-4.8<\/td><td>3,200-4,200<\/td><\/tr><tr><td>180-250\u33a1<\/td><td>NQ 200-250\u578b + 6-8\u53f0\u5185\u673a<\/td><td>4.5-5.8<\/td><td>3,800-5,000<\/td><\/tr><tr><td>250-300\u33a1<\/td><td>NQ 280-320\u578b + 8-10\u53f0\u5185\u673a \/ \u53cc\u4e3b\u673a<\/td><td>5.5-7.5<\/td><td>4,500-6,500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">AQ \u4e0d\u7528\u53e6\u914d\u6c34\u7bb1\u2014\u2014\u70ed\u6c34\u662f\u673a\u5668\u81ea\u5df1\u51fa\u7684\u3002\u4f46\u5faa\u73af\u6c34\u6cf5\u8981\u53e6\u914d\uff0c\u8fd9\u4e00\u9879\u8981\u5355\u72ec\u7b97\u8fdb\u9884\u7b97\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">5.3 \u901f\u67e5\u53e3\u8bc0<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u667a\u4eab\u51fa\u98ce\u51c9\uff0c\u5e8a\u5934\u52ff\u76f4\u5439\u3002<\/strong><br><strong>\u5357\u65b9\u5fc5\u51b2\u9664\u6e7f\u5f3a\uff0c\u61d2\u4eba\u798f\u97f3\u81ea\u6e05\u6d01\u3002<\/strong><br><strong>\u5c0f\u6237\u9009AQ\u4e00\u4f53\u673a\uff0c\u5927\u623fNQ\u53cc\u98ce\u6247\u3002<\/strong><br><strong>\u8981\u70ed\u6c34\u9009 AQ \u4e8c\u9009\u4e00\uff0c\u7eaf\u51b7\u6696\u9009 NQ \u5168\u81ea\u52a8\u3002<\/strong><\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx06\" class=\"wp-block-heading\">\u7b2c\u516d\u7ae0\uff1a\u7ade\u54c1\u5b9a\u4f4d\u2014\u2014\u540c\u95e8\u4e0e\u5bf9\u624b\u7684\u8fb9\u754c<\/h2>\n\n\n\n<p>\u65e5\u7acb\u5185\u90e8\u51e0\u6761\u4ea7\u54c1\u7ebf\u600e\u4e48\u5206\u5c42\u3001\u667a\u4eab\u5728\u91cc\u9762\u7ad9\u5728\u54ea\u4e2a\u4f4d\u7f6e\u3001\u54ea\u6761\u7ebf\u9002\u5408\u4ec0\u4e48\u4eba\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a>\u90a3\u4e00\u9875\u7684\u5bf9\u7167\u8868\u3002\u8fd9\u4e00\u7ae0\u53ea\u8bb2\u4e00\u4ef6\u4e8b\uff1a\u667a\u4eab\u548c\u81ea\u5bb6\u7684\u6c34\u5885\u9002\u600e\u4e48\u5206\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">6.2 \u667a\u4eab vs \u6c34\u5885\u9002\u6df1\u5ea6\u5bf9\u6bd4<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4e24\u8005\u540c\u4e3a\u65e5\u7acb\u4e24\u8054\u4f9b\u65d7\u8230\uff0c\u4f46\u6280\u672f\u8def\u7ebf\u622a\u7136\u4e0d\u540c\u3002\u9009\u5bf9\u8def\u7ebf\uff0c\u6bd4\u9009\u5bf9\u54c1\u724c\u66f4\u91cd\u8981\u3002<\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u667a\u4eab\uff08\u5929\u6c1f\u5730\u6c34\uff09<\/th><th>\u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09<\/th><th>\u9009\u62e9\u5efa\u8bae<\/th><\/tr><\/thead><tbody><tr><td>\u7a7a\u8c03\u4fa7\u539f\u7406<\/td><td>\u6c1f\u5229\u6602\u76f4\u51b7\uff08\u4e00\u6b21\u6362\u70ed\uff09<\/td><td>\u6c34\u5e26\u98ce\uff08\u4e8c\u6b21\u6362\u70ed\uff09<\/td><td>\u8ffd\u6c42\u5feb\u51b7\u2192\u667a\u4eab<\/td><\/tr><tr><td>\u51fa\u98ce\u6e29\u5ea6<\/td><td>5-14\u2103\uff08\u5168\u6548\u4e09\u7ba1\u5236\u8212\u723d\u6a21\u5f0f\u53ef\u63d0\u5230 18\u2103 \u4ee5\u4e0a\uff09<\/td><td>7-25\u2103<\/td><td>\u6015\u51b7\u98ce\u2192\u5148\u4e0a\u5168\u6548\u4e09\u7ba1\u5236<\/td><\/tr><tr><td>\u5236\u51b7\u901f\u5ea6<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u6781\u5feb\uff083\u5206\u949f\u5168\u5c4b\u964d\u6e29\uff09<\/td><td>\u2605\u2605\u2605 \u8f83\u6162\uff088-12\u5206\u949f\uff09<\/td><td>\u5357\u65b9\u590f\u5929\u2192\u667a\u4eab<\/td><\/tr><tr><td>\u9664\u6e7f\u80fd\u529b<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u53ef\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/td><td>\u2605\u2605 \u9700\u5236\u51b7\u624d\u80fd\u9664\u6e7f<\/td><td>\u6885\u96e8\u5b63\u521a\u9700\u2192\u667a\u4eab<\/td><\/tr><tr><td>\u5730\u6696\u4f53\u9a8c<\/td><td>\u6c34\u7cfb\u7edf\u5730\u9762\u8f90\u5c04\uff0c\u8212\u9002<\/td><td>\u6c34\u7cfb\u7edf\u5730\u9762\u8f90\u5c04\uff0c\u8212\u9002<\/td><td>\u4e24\u8005\u76f8\u540c<\/td><\/tr><tr><td>\u5b89\u88c5\u590d\u6742\u5ea6<\/td><td>\u2605\u2605\u2605 \u6807\u51c6\u5b89\u88c5<\/td><td>\u2605 \u6781\u590d\u6742\uff08\u6c34\u529b\u8ba1\u7b97+\u7f13\u51b2\u6c34\u7bb1\uff09<\/td><td>\u975e\u4e13\u4e1a\u56e2\u961f\u2192\u667a\u4eab<\/td><\/tr><tr><td>\u7cfb\u7edf\u7a33\u5b9a\u6027<\/td><td>\u9ad8\uff08\u7ba1\u8def\u7b80\u5355\uff09<\/td><td>\u4e2d\uff08\u7ba1\u8def\u590d\u6742\uff0c\u9700\u4e13\u4e1a\u8c03\u8bd5\uff09<\/td><td>\u8ffd\u6c42\u7701\u5fc3\u2192\u667a\u4eab<\/td><\/tr><tr><td>APF\u80fd\u6548<\/td><td>\u6700\u9ad86.15<\/td><td>~5.0-5.5<\/td><td>\u8ffd\u6c42\u8282\u80fd\u2192\u667a\u4eab<\/td><\/tr><tr><td>\u5065\u5eb7\u529f\u80fd<\/td><td>\u6807\u914dPE+\u81ea\u6e05\u6d01+\u9ad8\u6e29\u9664\u83cc<\/td><td>\u9700\u9009\u914d<\/td><td>\u5065\u5eb7\u521a\u9700\u2192\u667a\u4eab<\/td><\/tr><tr><td>\u4e94\u6052\u517c\u5bb9<\/td><td>\u2705 \u6c1f\u673a\u4e94\u6052\u57fa\u5ea7<\/td><td>\u2705 \u6c34\u673a\u4e94\u6052\u57fa\u5ea7<\/td><td>\u5747\u53ef<\/td><\/tr><tr><td>\u9002\u7528\u9762\u79ef<\/td><td>90-320\u33a1<\/td><td>120-500\u33a1<\/td><td>\u5927\u6237\u578b\u2192\u6c34\u5885\u9002<\/td><\/tr><tr><td>\u521d\u6295\u8d44<\/td><td>\u4e2d\u7b49<\/td><td>\u8f83\u9ad8<\/td><td>\u9884\u7b97\u6709\u9650\u2192\u667a\u4eab<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u603b\u7ed3<\/strong>\uff1a\u5357\u65b9\u9664\u6e7f\u521a\u9700\u3001\u8ffd\u6c42\u5feb\u51b7\u3001\u9884\u7b97\u53ef\u63a7\u2192<strong>\u667a\u4eab<\/strong>\uff1b\u6015\u51b7\u98ce\u3001\u60f3\u8981\u66f4\u67d4\u7684\u98ce\u611f\u2192<strong>\u5c0a\u777f\u5168\u6548\u2161 \u4e09\u7ba1\u5236<\/strong>\uff08\u8212\u723d\u6a21\u5f0f\uff0b\u5168\u5c4b\u5168\u611f\u9ad8\u663e\u70ed\u6a21\u5f0f\uff09\uff1b\u7a7a\u8c03\u9762\u79ef\u5927\u3001\u5e38\u4f4f\u4eba\u53e3\u5c11\uff08\u522b\u5885\u53ea\u4f4f\u4e24\u4e09\u4eba\uff09\u2192<strong>\u6c34\u5885\u9002<\/strong>\uff0c\u4e3b\u673a\u81ea\u7531\u3001\u4e0d\u53d7\u8fde\u63a5\u7387\u9650\u5236\u3002<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u51b3\u7b56\u4f9d\u636e<\/strong>\uff1a\u5982\u679c\u60a8\u4e0d\u60f3\u6df1\u5165\u7814\u7a76\u7cfb\u7edf\u539f\u7406\uff0c\u76f4\u63a5\u9009<strong>\u667a\u4eab<\/strong>\u2014\u2014\u5b83\u662f\u5929\u6c1f\u5730\u6c34\u54c1\u7c7b\u7684\"\u95ed\u773c\u5165\"\u9996\u9009\u3002\u6709\u4e00\u79cd\u60c5\u51b5\u91cd\u70b9\u8003\u8651\u6c34\u5885\u9002\uff1a\u5bb6\u4e2d\u8001\u4eba\u6781\u5ea6\u6015\u51b7\u98ce\uff08\u51fa\u98ce7-25\u2103 vs 5-14\u2103\uff09\uff0c\u53ef\u4ee5\u8003\u8651\u65e5\u7acb\u5168\u6548\u4e09\u7ba1\u5236\uff0c\u7528\u8212\u723d\u6a21\u5f0f\u6216\u8005\u5168\u5c4b\u5168\u611f\u9ad8\u663e\u70ed\u6a21\u5f0f\u6765\u89e3\u51b3\u51fa\u98ce\u53e3\u8fc7\u51b7\u7684\u95ee\u9898\uff0c\u5e76\u4e0d\u662f\u975e\u9009\u6c34\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u4e0d\u53ef\uff1b\u4f46\u662f\uff0c\u5982\u679c\u7a7a\u8c03\u9762\u79ef\u8fc7\u5927\uff0c\u4f46\u4f7f\u7528\u9762\u79ef\u7279\u522b\u5c0f\uff0c\u6bd4\u5982\u522b\u5885\u5e38\u4f4f\u4e24\u4e09\u4eba\uff0c\u53ef\u4ee5\u91cd\u70b9\u8003\u8651\u6c34\u5885\u9002\uff0c\u5229\u7528\u6c34\u673a\u7684\u4e3b\u673a\u53ef\u4ee5\u5b9e\u73b0\u4e3b\u673a\u81ea\u7531\u3001\u4e0d\u53d7\u8fde\u63a5\u7387\u9650\u5236\uff0c\u8ba9\u4e00\u6b21\u6027\u6295\u5165\u548c\u4f7f\u7528\u66f4\u8282\u7701\u3002\u9664\u6b64\u4e4b\u5916\uff0c\u667a\u4eab\u5728\u5236\u51b7\u901f\u5ea6\u3001\u9664\u6e7f\u80fd\u529b\u3001\u5b89\u88c5\u4fbf\u5229\u6027\u3001\u80fd\u6548\u548c\u5065\u5eb7\u529f\u80fd\u4e0a\u5168\u9762\u5360\u4f18\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx07\" class=\"wp-block-heading\">\u7b2c\u4e03\u7ae0\uff1a\u5929\u6c1f\u5730\u6c34 vs \u71c3\u6c14\u58c1\u6302\u7089\u2014\u2014\u5168\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u5ba2\u6237\u51b3\u7b56\u6700\u7ea0\u7ed3\u7684\u5bf9\u6bd4\u4e4b\u4e00\uff1a\u7a7a\u6c14\u80fd\u5730\u6696\u5230\u5e95\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u597d\u5728\u54ea\uff1f\u503c\u4e0d\u503c\u5f97\u591a\u82b1\u94b1\uff1f\u672c\u7ae0\u7528\u6570\u636e\u8bf4\u8bdd\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">7.1 \u516d\u7ef4\u5ea6\u6838\u5fc3\u5bf9\u6bd4\u8868<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ef4\u5ea6<\/th><th>\u5929\u6c1f\u5730\u6c34\uff08\u667a\u4eab+\u6c34\u6a21\u5757\uff09<\/th><th>\u71c3\u6c14\u58c1\u6302\u7089\uff08\u51b7\u51dd\u7089\uff09<\/th><th>\u71c3\u6c14\u58c1\u6302\u7089\uff08\u666e\u901a\u7089\uff09<\/th><th>\u5dee\u5f02\u5206\u6790<\/th><\/tr><\/thead><tbody><tr><td>\u80fd\u6548<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5236\u70edCOP\u22653.0\uff0c1\u5ea6\u7535\u642c3\u4efd\u70ed<\/td><td>\u2b50\u2b50\u2b50 \u6548\u7387\u7ea695%\uff08\u4f4e\u6e29\u5de5\u51b5\uff09<\/td><td>\u2b50\u2b50 \u6548\u7387\u7ea690%<\/td><td>\u5730\u6696\u8fd0\u884c\u8d39\u4ec5\u4e3a\u58c1\u6302\u7089\u768440%-60%<\/td><\/tr><tr><td>\u8fd0\u884c\u8d39(100\u33a1\/\u5b63)<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u7ea62,400\u5143<\/td><td>\u2b50\u2b50\u2b50 \u7ea63,156\u5143<\/td><td>\u2b50\u2b50 \u7ea63,780\u5143<\/td><td>\u6bcf\u5e74\u6bd4\u51b7\u51dd\u7089\u7701\u7ea6756\u5143\uff0c\u6bd4\u666e\u901a\u7089\u7701\u7ea61,380\u5143<\/td><\/tr><tr><td>\u8bbe\u5907\u5bff\u547d<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 20\u5e74\u4ee5\u4e0a<\/td><td>\u2b50\u2b50 8-10\u5e74<\/td><td>\u2b50 8\u5e74<\/td><td>\u5929\u6c1f\u5730\u6c34\u5bff\u547d\u662f\u58c1\u6302\u7089\u76842\u500d\u4ee5\u4e0a<\/td><\/tr><tr><td>\u7ef4\u4fee\u4fdd\u517b<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u7a7a\u8c03\u4fa7\u514d\u7ef4\u62a4\uff0c\u6c34\u6a21\u5757\u5e74\u8d39\u7ea60-100\u5143<\/td><td>\u2b50\u2b50\u2b50 \u9700\u5b9a\u671f\u4fdd\u517b\uff0c\u5e74\u8d39\u7ea6400\u5143<\/td><td>\u2b50\u2b50\u2b50 \u5e74\u8d39\u7ea6100\u5143<\/td><td>\u5929\u6c1f\u5730\u6c34\u540e\u671f\u66f4\u7701\u5fc3\u7701\u94b1<\/td><\/tr><tr><td>\u73af\u4fdd\u6027<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u7528\u7535\uff0c\u65e0\u5e9f\u6c14\u6392\u653e<\/td><td>\u2b50\u2b50 \u6392\u653eCO\u2082\u3001NOx<\/td><td>\u2b50\u2b50 \u6392\u653eCO\u2082\u3001NOx<\/td><td>\u5929\u6c1f\u5730\u6c34\u66f4\u7eff\u8272\u73af\u4fdd<\/td><\/tr><tr><td>\u521d\u6295\u8d44<\/td><td>\u2b50\u2b50 \u76f8\u5bf9\u8f83\u9ad8\uff08\u4f46\u5df2\u6709\u7a7a\u8c03\u4ec5\u52a0\u6c34\u6a21\u5757\u6210\u672c\u4f4e\uff09<\/td><td>\u2b50\u2b50\u2b50 \u4e2d\uff08\u7ea61.5-2\u4e07\uff09<\/td><td>\u2b50\u2b50\u2b50\u2b50 \u4f4e\uff08\u7ea60.8-1\u4e07\uff09<\/td><td>\u5df2\u6709\u7a7a\u8c03\u7528\u6237\u589e\u52a0\u6c34\u6a21\u5757\u4ec5\u9700\u7ea61\u4e07\u5143\uff0c\u6027\u4ef7\u6bd4\u6781\u9ad8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">7.2 \u529f\u80fd\u4e0e\u7cfb\u7edf\u5dee\u5f02\u6df1\u5ea6\u89e3\u6790<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u7cfb\u7edf\u96c6\u6210\u5ea6\u4e0e\u7a7a\u95f4\u5dee\u5f02<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>AQ\uff08\u4e00\u4f53\u673a\uff09<\/strong>\uff1a\u6c34\u6a21\u5757\u76f4\u63a5\u96c6\u6210\u5728\u5ba4\u5916\u673a\u5185\uff0c\u5b89\u88c5\u65f6\u65e0\u9700\u989d\u5916\u7a7a\u95f4\u5b58\u653e\u72ec\u7acb\u7684\u6c34\u6a21\u5757\u3002\u5916\u673a\u5c3a\u5bf8\u7d27\u51d1\uff08\u5bbd1100mm\uff0c\u9ad8840mm\uff09\uff0c\u975e\u5e38\u9002\u5408\u5916\u673a\u4f4d\u7d27\u5f20\u7684\u5c0f\u6237\u578b\u3001\u5e73\u5c42\u7528\u6237\u3002<\/li>\n\n\n\n<li><strong>NQ\uff08\u4e00\u4f53\u673a\uff09<\/strong>\uff1a\u6c34\u6a21\u5757\u540c\u6837\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u9762\uff0c\u51fa\u5382\u914d\u597d\uff0c\u4e0d\u53e6\u4e70\u4e5f\u4e0d\u9700\u8981\u8bbe\u5907\u95f4\u3002NQ \u7684\u5f3a\u9879\u662f\u51b7\u91cf\uff0c\u6700\u5927\u5230 320 \u578b\uff0c\u80fd\u5e26\u66f4\u591a\u5ba4\u5185\u673a\u3002<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u751f\u6d3b\u70ed\u6c34\u5dee\u5f02\uff08AQ\u6838\u5fc3\u5356\u70b9\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u529f\u80fd<\/th><th>AQ\uff08\u5929\u6c1f\u70ed\u6c34\uff09<\/th><th>NQ\uff08\u7eaf\u5929\u6c1f\u5730\u6c34\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u7a7a\u8c03\u5236\u51b7<\/td><td>\u2705 \u652f\u6301<\/td><td>\u2705 \u652f\u6301<\/td><\/tr><tr><td>\u5730\u6696\u91c7\u6696<\/td><td>\u2705 \u652f\u6301<\/td><td>\u2705 \u652f\u6301\uff08\u6c34\u6a21\u5757\u5185\u7f6e+\u5730\u6696\u7ba1\u7f51\uff09<\/td><\/tr><tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u6709\uff0c\u4f46\u4e0e\u5730\u6696\u4e8c\u9009\u4e00\uff0c\u540c\u4e00\u65f6\u95f4\u53ea\u8d70\u4e00\u4e2a\u529f\u80fd<\/td><td>\u274c \u4e0d\u652f\u6301<\/td><\/tr><tr><td>\u5178\u578b\u914d\u7f6e<\/td><td>\u4e00\u53f0\u4e3b\u673a+\u6c34\u7bb1+\u5ba4\u5185\u673a<\/td><td>\u4e00\u53f0\u4e3b\u673a\uff08\u6c34\u6a21\u5757\u5728\u673a\u5185\uff09+\u5ba4\u5185\u673a\uff0c\u70ed\u6c34\u53e6\u914d\u70ed\u6c34\u5668<\/td><\/tr><tr><td>\u7cfb\u7edf\u590d\u6742\u5ea6<\/td><td>\u8f83\u9ad8\uff08\u591a\u4e86\u70ed\u6c34\u529f\u80fd\uff09<\/td><td>\u57fa\u7840\uff08\u4e24\u8054\u4f9b\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">7.3 20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\uff08\u957f\u671f\u7ecf\u6d4e\u6027\u5206\u6790\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u8ba1\u7b97\u53c2\u6570<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u53d6\u503c<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>100\u33a1<\/td><td>\u6807\u51c6\u6237\u578b<\/td><\/tr><tr><td>\u70ed\u8d1f\u8377\u6807\u51c6<\/td><td>50W\/\u33a1<\/td><td>\u9f99\u8109\u6696\u901a\u56de\u8bbf\u5b9e\u8bc1\u6570\u636e<\/td><\/tr><tr><td>\u91c7\u6696\u5b63<\/td><td>120\u5929<\/td><td>\u6210\u90fd\u6807\u51c6\u91c7\u6696\u5b63<\/td><\/tr><tr><td>\u8fd0\u884c\u65f6\u95f4<\/td><td>24\u5c0f\u65f6\/\u5929<\/td><td>\u5730\u6696\u5168\u5929\u5f00\u542f<\/td><\/tr><tr><td>\u7535\u4ef7<\/td><td>0.55\u5143\/\u5ea6<\/td><td>\u5c45\u6c11\u7528\u7535<\/td><\/tr><tr><td>\u6c14\u4ef7<\/td><td>2.5\u5143\/m\u00b3<\/td><td>\u6210\u90fd\u71c3\u6c14\u9636\u68af\u4ef7\u53d6\u4e2d<\/td><\/tr><tr><td>\u666e\u901a\u7089\u521d\u6295\u8d44<\/td><td>8,000\u5143<\/td><td>\u5047\u8bbe\u5168\u5305\u4ef7<\/td><\/tr><tr><td>\u51b7\u51dd\u7089\u521d\u6295\u8d44<\/td><td>15,000\u5143<\/td><td>\u5047\u8bbe\u5168\u5305\u4ef7<\/td><\/tr><tr><td>\u6c34\u6a21\u5757\u521d\u6295\u8d44<\/td><td>10,500\u5143<\/td><td>\u6c34\u6a21\u5757\uff08\u5982RWMG-160FWXNZQ\uff09+\u5730\u6696\u4e3b\u7ba1\u8d39\u7528<\/td><\/tr><tr><td>\u5bff\u547d<\/td><td>\u58c1\u6302\u70898-10\u5e74 \/ \u7a7a\u6c14\u80fd\u4e3b\u673a20\u5e74\u4ee5\u4e0a<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\u8868<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u666e\u901a\u7089<\/th><th>\u51b7\u51dd\u7089<\/th><th>\u5929\u6c1f\u5730\u6c34\uff08\u5df2\u6709\u7a7a\u8c03+\u6c34\u6a21\u5757\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u70ed\u6e90\u521d\u6295\u8d44<\/td><td>8,000\u5143<\/td><td>15,000\u5143<\/td><td>10,500\u5143\uff08\u6c34\u6a21\u5757+\u4e3b\u7ba1\uff09<\/td><\/tr><tr><td>20\u5e74\u8fd0\u884c\u8d39<\/td><td>85,200\u5143\uff08\u5e743,780\u00d720+\u901a\u80c0\uff09<\/td><td>76,240\u5143\uff08\u5e743,156\u00d720+\u901a\u80c0\uff09<\/td><td>52,960\u5143\uff08\u5e742,400\u00d720+\u901a\u80c0\uff09<\/td><\/tr><tr><td>\u8bbe\u5907\u66f4\u6362\u8d39<\/td><td>+16,000\u5143\uff08\u6bcf10\u5e74\u63621\u6b21\uff0c\u51712\u6b21\uff09<\/td><td>+15,000\u5143\uff08\u6bcf12\u5e74\u63621\u6b21\uff0c\u51711.5\u6b21\uff09<\/td><td>0\u5143\uff08\u6838\u5fc3\u8bbe\u590720\u5e74\u5bff\u547d\u65e0\u9700\u66f4\u6362\uff09<\/td><\/tr><tr><td><strong>\u603b\u6295\u5165<\/strong><\/td><td><strong>\u7ea6109,200\u5143<\/strong><\/td><td><strong>\u7ea6106,240\u5143<\/strong><\/td><td><strong>\u7ea663,460\u5143<\/strong><\/td><\/tr><tr><td>\u8282\u7701<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u5bf9\u6bd4\u51b7\u51dd\u7089\u7701<strong>42,780\u5143<\/strong>\uff0c\u5bf9\u6bd4\u666e\u901a\u7089\u7701<strong>45,740\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">7.4 \u5730\u6696\u8fd0\u884c\u8d39\u7528\u5bf9\u6bd4\uff08\u65e5\u8d39\u7528\/\u5b63\u8d39\u7528\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u70ed\u6e90\u7c7b\u578b<\/th><th>\u65e5\u8d39\u7528\uff08\u7ea6\uff09<\/th><th>\u5b63\u8d39\u7528\uff08\u7ea6\uff0c120\u5929\uff09<\/th><\/tr><\/thead><tbody><tr><td>\u666e\u901a\u7089<\/td><td>31.5\u5143<\/td><td>3,780\u5143<\/td><\/tr><tr><td>\u51b7\u51dd\u7089<\/td><td>26.3\u5143<\/td><td>3,156\u5143<\/td><\/tr><tr><td>\u7a7a\u6c14\u80fd\uff08COP 3.0\uff0c\u5929\u6c1f\u5730\u6c34\uff09<\/td><td>20\u5143<\/td><td>2,400\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u5929\u6c1f\u5730\u6c34\u6bcf100\u33a1\u5730\u6696\uff0c\u6bcf\u5e74\u4e3a\u5ba2\u6237\u8282\u7701\u7ea6750-1,400\u5143\u91c7\u6696\u8d39\u7528\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">7.5 \u6295\u8d44\u56de\u6536\u671f\u8ba1\u7b97\uff08\u9488\u5bf9\u5df2\u6709\u7a7a\u8c03\u7528\u6237\uff09<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u524d\u63d0\uff1a\u5ba2\u6237\u5df2\u5b89\u88c5\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff08\u5982\u5c0a\u777f\u3001VAM mini\u7b49\uff09\uff0c\u5e0c\u671b\u589e\u52a0\u5730\u6696\u529f\u80fd\u3002<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u65b9\u6848\u5bf9\u6bd4<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65b9\u6848<\/th><th>\u914d\u7f6e<\/th><th>\u603b\u521d\u6295\u8d44<\/th><\/tr><\/thead><tbody><tr><td><strong>A<\/strong>\uff1a\u589e\u52a0\u6c34\u6a21\u5757+\u5730\u6696<\/td><td>\u6c34\u6a21\u5757RWMG-160\uff088,375\u5143+\u5b89\u88c5625\u5143\uff09+ \u5730\u6696\u7cfb\u7edf100\u33a1\uff0816,900\u5143\uff09<\/td><td><strong>\u7ea625,900\u5143<\/strong><\/td><\/tr><tr><td><strong>B<\/strong>\uff1a\u51b7\u51dd\u7089+\u5730\u6696<\/td><td>\u83f2\u65af\u66fcB1KF 25KW\uff0817,656\u5143+\u5b89\u88c5600\u5143\uff09+ \u5730\u6696\u7cfb\u7edf\uff0816,900\u5143\uff09<\/td><td><strong>\u7ea635,156\u5143<\/strong><\/td><\/tr><tr><td><strong>C<\/strong>\uff1a\u666e\u901a\u7089+\u5730\u6696<\/td><td>\u83f2\u65af\u66fcA1JE 24KW\uff088,311\u5143+\u5b89\u88c5600\u5143\uff09+ \u5730\u6696\u7cfb\u7edf\uff0816,900\u5143\uff09<\/td><td><strong>\u7ea625,811\u5143<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u56de\u6536\u671f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6c34\u6a21\u5757 vs \u51b7\u51dd\u7089<\/strong>\uff1a\u521d\u6295\u8d44\u4f4e9,256\u5143\uff1b\u5e74\u8fd0\u884c\u8d39\u7701756\u5143\u3002<strong>\u521d\u6295\u8d44\u5373\u8d5a\uff0c\u4e14\u540e\u7eed\u6bcf\u5e74\u7701\u6c14\u8d39\u3002<\/strong><\/li>\n\n\n\n<li><strong>\u6c34\u6a21\u5757 vs \u666e\u901a\u7089<\/strong>\uff1a\u521d\u6295\u8d44\u9ad889\u5143\uff08\u51e0\u4e4e\u6301\u5e73\uff09\uff1b\u5e74\u8fd0\u884c\u8d39\u77011,380\u5143\u3002<strong>\u6295\u8d44\u56de\u6536\u671f\u7ea61\u4e2a\u6708\uff0c\u4e4b\u540e\u6bcf\u5e74\u51c0\u77011,380\u5143\u3002<\/strong><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">7.6 \u4e00\u53e5\u8bdd\u7ed3\u8bba<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5929\u6c1f\u5730\u6c34\uff08\u7a7a\u6c14\u80fd\uff09\u80fd\u6548\u6700\u9ad8\u3001\u8fd0\u884c\u8d39\u6700\u4f4e\u3001\u5bff\u547d\u6700\u957f\u3002\u867d\u7136\u521d\u6295\u8d44\uff08\u7eaf\u5730\u6696\u65b9\u6848\uff09\u4e0e\u58c1\u6302\u7089\u57fa\u672c\u6301\u5e73\uff0c\u4f46\u5bf9\u5df2\u6709\u4e2d\u592e\u7a7a\u8c03\u7684\u5bb6\u5ead\uff0c\u589e\u52a0\u6c34\u6a21\u5757\u505a\u5730\u6696\u4ec5\u9700\u7ea61\u4e07\u5143\uff0c<strong>20 \u5e74\u603b\u6295\u5165\u6bd4\u71c3\u6c14\u58c1\u6302\u7089\u8282\u7701\u8d85\u8fc7 4 \u4e07\u5143<\/strong>\u8fd9\u662f\u6027\u4ef7\u6bd4\u6700\u9ad8\u7684\u5730\u6696\u5347\u7ea7\u65b9\u6848\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">7.7 \u5e38\u89c1\u5ba2\u6237\u7591\u8651<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5ba2\u6237\u95ee<\/th><th>\u6211\u4eec\u7684\u56de\u7b54<\/th><\/tr><\/thead><tbody><tr><td>\u7a7a\u6c14\u80fd\u5730\u6696\u51ac\u5929\u591f\u70ed\u5417\uff1f<\/td><td>\u5b8c\u5168\u591f\u3002\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u91c7\u7528\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a\uff0c\u5728<strong>-20\u2103 \u73af\u5883\u4e0b\u7a33\u5b9a\u8fd0\u884c\uff0c\u5730\u6696\u51fa\u6c34\u53ef\u8fbe 55\u2103\uff0c\u5ba4\u6e29\u7ef4\u6301\u5728 20-22\u2103<\/strong>\u3002\u56de\u8bbf\u6570\u636e\u663e\u793a\uff0c\u5ba2\u6237\u5b9e\u9645\u91c7\u6696\u80fd\u8017\u4ec528-30W\/\u33a1\uff0c\u8fdc\u4f4e\u4e8e\u4f20\u7edf\u8bbe\u8ba1\u6807\u51c6\u3002<\/td><\/tr><tr><td>\u6c34\u6a21\u5757\u5bb9\u6613\u574f\u5417\uff1f<\/td><td>\u4f7f\u7528\u5bff\u547d\u4e0e\u7a7a\u8c03\u4e3b\u673a\u4e00\u81f4\uff0820\u5e74\u4ee5\u4e0a\uff09\u3002\u5185\u7f6e\u53d8\u9891\u6c34\u6cf5\uff0c\u8fd0\u884c\u7a33\u5b9a\u3002\u6574\u4e2a\u7cfb\u7edf\u7531\u6c34\u6a21\u5757\u81ea\u52a8\u7ba1\u7406\uff0c\u65e0\u989d\u5916\u7ef4\u62a4\u8d1f\u62c5\u3002<\/td><\/tr><tr><td>\u4e3a\u4ec0\u4e48\u6c34\u6a21\u5757\u6bd4\u58c1\u6302\u7089\u4fbf\u5b9c\uff1f<\/td><td>\u56e0\u4e3a\u6c34\u6a21\u5757\u4e0d\u662f\u72ec\u7acb\u70ed\u6e90\uff0c\u662f\u7a7a\u8c03\u7cfb\u7edf\u7684\u529f\u80fd\u6269\u5c55\u3002\u4e3b\u673a\u538b\u7f29\u673a\u3001\u6362\u70ed\u5668\u7b49\"\u503c\u94b1\"\u7684\u90e8\u4ef6\u5df2\u5b89\u88c5\u5728\u7a7a\u8c03\u5916\u673a\u4e2d\uff0c\u6c34\u6a21\u5757\u53ea\u662f\u505a\u4e86\u4e00\u6b21\u80fd\u91cf\u8f6c\u6362\u3002\u53ea\u9700\u82b1\u4e00\u4e2a\u914d\u4ef6\u7684\u94b1\uff0c\u5c31\u62e5\u6709\u4e86\u4e00\u4e2a\u5e38\u5e74\u8fd0\u884c\u8d39\u6781\u4f4e\u7684\u5730\u6696\u70ed\u6e90\u3002<\/td><\/tr><tr><td>\u505c\u7535\u4e86\u600e\u4e48\u529e\uff1f<\/td><td>\u4e0e\u58c1\u6302\u7089\u76f8\u540c\uff0c\u505c\u7535\u540e\u7cfb\u7edf\u505c\u6b62\u8fd0\u884c\u3002\u6062\u590d\u4f9b\u7535\u540e\u81ea\u52a8\u91cd\u542f\u3002\u5efa\u8bae\u522b\u5885\u7528\u6237\u914d\u7f6e\u5c0f\u578b\u53d1\u7535\u673a\u6216UPS\u5907\u7528\u7535\u6e90\u3002<\/td><\/tr><tr><td>\u590f\u5b63\u5236\u51b7\u6548\u679c\u6bd4\u666e\u901a\u7a7a\u8c03\u597d\u5417\uff1f<\/td><td>\u5236\u51b7\u539f\u7406\u5b8c\u5168\u76f8\u540c\uff08\u6c1f\u5229\u6602\u76f4\u51b7\uff09\uff0c\u4f46\u667a\u4eab\u642d\u8f7d\u5168\u76f4\u6d41\u53d8\u9891+\u667a\u80fd\u9664\u971c\uff0c\u7efc\u5408\u80fd\u6548\u66f4\u9ad8\u3002\u5ba4\u5185\u673a\u6807\u914d\u81ea\u6e05\u6d01\uff0c\u51fa\u98ce\u66f4\u5e72\u51c0\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">7.8\u3001\u8fd9\u4e9b\u60c5\u51b5\u6211\u4eec\u53cd\u800c\u4e0d\u63a8\u8350<\/h3>\n\n<div style=\"background:#FDF6EC;border-left:4px solid #B7791F;padding:14px 18px;margin:14px 0;line-height:1.9;\">\n<p><b>\u5148\u628a\u6211\u4eec\u7684\u5e95\u6c14\u6446\u5728\u684c\u9762\u4e0a\uff1a<\/b>\u6211\u4eec\u7d2f\u8ba1\u4e0a\u95e8 8712 \u6b21\uff0c\u91c7\u6696\u76f8\u5173\u7684\u4e24\u5927\u6050\u60e7\u2014\u2014<b>\u4e0d\u70ed<\/b>\uff08\u7ea6 490 \u6b21\uff09\u548c<b>\u6f0f\u6c34<\/b>\uff08\u7ea6 510 \u6b21\uff09\u2014\u2014\u5927\u591a\u6570\u6839\u6e90\u4e0d\u5728\u7089\u5b50\u548c\u7ba1\u5b50\u672c\u8eab\uff0c\u800c\u5728\u8bbe\u8ba1\u4e0e\u5b89\u88c5\u73af\u8282\uff1a\u8d1f\u8377\u6ca1\u6709\u9010\u95f4\u7b97\u3001\u7ba1\u8def\u4e0d\u6309\u6807\u51c6\u505a\u3001\u9a8c\u6536\u8d70\u8fc7\u573a\u3002\u8fd9\u5c31\u662f\u6211\u4eec\u575a\u6301\"\u5148\u52d8\u6d4b\u51fa\u56fe\u3001\u6309\u56fe\u65bd\u5de5\u3001\u9010\u9879\u9a8c\u6536\"\u7684\u539f\u56e0\u3002<\/p>\n\n<p><b>\u6b63\u5728\u6bd4\u4ef7\u7684\u5bb6\u5ead\uff0c\u5efa\u8bae\u628a\u8fd9\u51e0\u6761\u4e5f\u62ff\u53bb\u5bf9\u6bd4\u522b\u5bb6\uff1a<\/b><\/p>\n<p>\u2460 \u70ed\u8d1f\u8377\u662f\u4e0d\u662f\u9010\u95f4\u6838\u7b97\u7684\u2014\u2014\u6210\u90fd\u4f4f\u5b85\u6309 100W\/\u33a1 \u53d6\u57fa\u7ebf\uff0c\u897f\u6652\u3001\u9876\u5c42\u3001\u843d\u5730\u7a97\u8981\u4e0a\u6d6e\uff0c\u4e00\u53e3\u4ef7\u6309\u9762\u79ef\u4e58\u5355\u4ef7\u7684\u591a\u534a\u6ca1\u7b97\uff1b<br>\n\u2461 \u76d8\u7ba1\u95f4\u8ddd\u3001\u4e3b\u7ba1\u7ba1\u5f84\u5199\u7684\u4ec0\u4e48\u6807\u51c6\u2014\u2014\u80fd\u4e0d\u80fd\u5199\u8fdb\u5408\u540c\uff1b<br>\n\u2462 \u6253\u538b\u8bd5\u9a8c\u4fdd\u538b\u591a\u4e45\u3001\u9690\u853d\u5de5\u7a0b\u600e\u4e48\u9a8c\u6536\u2014\u2014\u6709\u6ca1\u6709\u9010\u9879\u9a8c\u6536\u5355\uff1b<br>\n\u2463 \u62a5\u4ef7\u662f\u4e00\u6b21\u5217\u6e05\uff0c\u8fd8\u662f\"\u5f00\u5934\u62a5\u591a\u5c11\u3001\u540e\u671f\u8fd9\u513f\u52a0\u90a3\u513f\u52a0\"\u3002<\/p>\n\n<p><b>\u4ee5\u4e0b\u60c5\u51b5\uff0c\u6211\u4eec\u4f1a\u5efa\u8bae\u60a8\u5148\u7f13\u4e00\u7f13\uff1a<\/b><\/p>\n<p>\u2460 \u623f\u5b50\u662f\u6295\u8d44\u8fc7\u6e21\u623f\uff0c\u79df\u5ba2\u5bf9\u8212\u9002\u4e0d\u654f\u611f\u2014\u2014\u914d\u7f6e\u53ef\u4ee5\u4ece\u7b80\uff0c\u4e0d\u5fc5\u4e0a\u9ad8\u914d\uff1b<br>\n\u2461 \u53ea\u60f3\u62ff\u4e00\u4efd\u914d\u7f6e\u5355\u53bb\u522b\u5bb6\u538b\u4ef7\u2014\u2014\u6211\u4eec\u53ef\u4ee5\u7ed9\u60a8\u5224\u65ad\u7684\u5c3a\u5b50\uff08\u8d1f\u8377\u3001\u76d8\u7ba1\u3001\u7ba1\u5f84\u3001\u8f85\u6750\u3001\u8d28\u4fdd\uff09\uff0c\u6df1\u5ea6\u65b9\u6848\u8981\u7b49\u610f\u5411\u660e\u786e\u518d\u505a\uff1b<br>\n\u2462 \u60f3\u7528\u6700\u4f4e\u4ef7\u903c\u51fa\"\u540c\u914d\u7f6e\u66f4\u4f4e\u62a5\u4ef7\"\u2014\u2014\u914d\u7f6e\u5dee\u4e00\u70b9\uff0c\u7528\u8d77\u6765\u5dee\u5f88\u591a\uff0c\u6211\u4eec\u4e0d\u63a5\u8fd9\u79cd\u5bf9\u6bd4\u65b9\u5f0f\uff0c\u4f46\u6559\u60a8\u600e\u4e48\u5bf9\u6bd4\u3002<\/p>\n<\/div>\n\n<h3 class=\"wp-block-heading\">7.9\u3001\u6210\u90fd\u5ba2\u6237\u771f\u5b9e\u8bf4\u8fc7\u7684\u8bdd<\/h3>\n\n<div style=\"background:#F0F7F4;border-left:4px solid #2E7D5B;padding:14px 18px;margin:14px 0;line-height:1.9;font-size:14.5px;\">\n<p>\"\u522b\u5885\u5ba2\u6237\uff1a\u8001\u4eba\u4f4f\u4e00\u697c\uff0c<b>\u907f\u76f4\u5439<\/b>\uff0c\u5730\u6696\u6309 100W\/\u33a1\uff0c\u5ba4\u6e29\u8981 20\uff5e22\u2103\u3002\"\u2014\u2014\u5206\u5ba4\u63a7\u6e29\u4ece\u8fd9\u4e00\u53e5\u5f00\u59cb\u8bbe\u8ba1<br>\n\"\u6210\u90fd\u51ac\u591c\u6700\u4f4e 1\uff5e5\u2103\uff0c<b>\u6e29\u5dee\u8d85\u8fc7 15 \u5ea6\u4e0d\u8212\u9002<\/b>\u3002\"\u2014\u2014\u5ba2\u6237\u81ea\u5df1\u7b97\u7684\u8212\u9002\u8d26<br>\n\"<b>\u6838\u5fc3\u8bc9\u6c42\uff1a\u8282\u80fd + \u89c4\u907f\u6f0f\u6c34\u566a\u97f3\u98ce\u9669<\/b>\u3002\"\u2014\u2014\u4e24\u53e5\u8bdd\u5b9a\u4e86\u4e00\u5957\u65b9\u6848\u7684\u4e3b\u7ebf<br>\n\"\u6015\u5b89\u88c5\u4e0d\u4e13\u4e1a\u3001<b>\u6f0f\u6c34\u6ce1\u9876<\/b>\u3001\u552e\u540e\u627e\u4e0d\u5230\u4eba\u3002\"\u2014\u2014\u660e\u88c5\u5ba2\u6237\u6700\u5e38\u89c1\u7684\u7b2c\u4e00\u987e\u8651<\/p>\n<p style=\"color:#5A6B7C;font-size:13px;\">\u4ee5\u4e0a\u5747\u4e3a\u5ba2\u6237\u539f\u8bdd\uff08\u5df2\u8131\u654f\uff09\u3002\u60a8\u6700\u62c5\u5fc3\u54ea\u4e00\u6761\uff0c\u52d8\u6d4b\u65f6\u5c31\u5148\u804a\u54ea\u4e00\u6761\u3002<\/p>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx08\" class=\"wp-block-heading\">\u7b2c\u516b\u7ae0\uff1a\u5b89\u88c5\u89c4\u8303\u2014\u2014\u6807\u51c6\u5316\u65bd\u5de5\u5168\u6d41\u7a0b<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">8.1 \u5b89\u88c5\u524d\u51c6\u5907\u6e05\u5355<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u51c6\u5907\u9879<\/th><th>\u8981\u6c42<\/th><th>\u5907\u6ce8<\/th><\/tr><\/thead><tbody><tr><td>\u7535\u6e90<\/td><td>AQ\/NQ\u5c0f\u578b\u53f7\uff1a220V\/50Hz\u72ec\u7acb\u56de\u8def\uff1bNQ\u5927\u578b\u53f7\uff08200+\uff09\uff1a380V\u4e09\u76f8\u7535\u72ec\u7acb\u56de\u8def<\/td><td>\u5927\u578b\u53f7\u9700\u7269\u4e1a\u5ba1\u6279<\/td><\/tr><tr><td>\u5916\u673a\u4f4d<\/td><td>\u901a\u98ce\u826f\u597d\uff0c\u9884\u7559\u68c0\u4fee\u7a7a\u95f4\uff08\u524d\u2265500mm\uff0c\u540e\u2265300mm\uff09<\/td><td>AQ\u4e00\u4f53\u5f0f\u6bd4\u4f20\u7edf\u65b9\u6848\u770130%\u7a7a\u95f4<\/td><\/tr><tr><td>\u94dc\u7ba1<\/td><td>R410A\u4e13\u7528\u53bb\u6c27\u94dc\u7ba1\uff0c\u58c1\u539a\u22650.8mm<\/td><td>\u4e25\u7981\u4f7f\u7528\u52a3\u8d28\u94dc\u7ba1<\/td><\/tr><tr><td>\u5730\u6696\u76d8\u7ba1<\/td><td>PERT\/PEX\u7ba1\uff0cde20\u7ba1\u95f4\u8ddd200mm\uff08\u6309\u70ed\u8d1f\u8377\u4e0e\u6d41\u91cf\u6838\u7b97\u786e\u5b9a\uff0c\u7ea620\u33a1\u4e00\u4e2a\u56de\u8def\uff09\uff0cde16\u7ba1\u95f4\u8ddd125mm\uff08\u6309\u70ed\u8d1f\u8377\u4e0e\u6d41\u91cf\u6838\u7b97\u786e\u5b9a\uff0c\u7ea610\u33a1\u4e00\u4e2a\u56de\u8def\uff0c\u8fb9\u7f18\u533a\u57df\u52a0\u5bc6\uff09<\/td><td>\u6839\u636e\u70ed\u8d1f\u8377\u8ba1\u7b97\u786e\u5b9a<\/td><\/tr><tr><td>\u51b7\u51dd\u6c34\u7ba1<\/td><td>\u5761\u5ea6\u22651%\uff0c\u4fdd\u6e29\u5305\u88f9<\/td><td>\u9632\u6b62\u7ed3\u9732\u6ef4\u6c34<\/td><\/tr><tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u9884\u7559WiFi\u7ebf\u63a7\u566886\u5e95\u76d2<\/td><td>\u6807\u914d5G\u7269\u8054<\/td><\/tr><tr><td>\u5916\u673a\u4f4d\uff08\u4e00\u4f53\u673a\uff09<\/td><td>\u667a\u4eab AQ\uff0fNQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u5728\u673a\u5668\u91cc\uff1b\u5916\u673a\u4f4d\u6309\u300c\u5e26\u6c34\u8def\u7684\u673a\u5668\u300d\u7559\uff1a\u901a\u98ce\u3001\u6392\u6c34\u3001\u68c0\u4fee\u7a7a\u95f4<\/td><td>\u5f88\u591a\u5c0f\u533a\u6309\u666e\u901a\u7a7a\u8c03\u7559\u4f4d\uff0c\u88c5\u4e00\u4f53\u673a\u4f1a\u5361<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<details style=\"background:#f7f9fc;padding:14px;border-radius:10px;margin:16px 0;border:1px solid #e2e8f0;\"><summary style=\"font-weight:bold;cursor:pointer;\">\ud83d\udcce \u9644\u5f55\uff1a\u9f99\u8109\u5730\u6696\u8bbe\u8ba1\u6280\u672f\u57fa\u51c6\uff08\u8bbe\u8ba1\u53e3\u5f84\u3001\u516c\u5f0f\u4e0e\u56de\u8def\u6807\u51c6\uff09<\/summary><div style=\"margin-top:12px;font-size:13px;line-height:1.7;color:#333;\"><p>\u672c\u57fa\u51c6\u4f9d\u636e\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142-2012 \u53ca\u9f99\u8109\u5de5\u7a0b\u5b9e\u8df5\u5236\u5b9a\uff0c\u9002\u7528\u4e8e\u6210\u90fd\u5730\u533a\u58c1\u6302\u7089\uff08\u71c3\u6c14\u70ed\u6e90\uff09\u5e26\u6e7f\u5f0f\u6c34\u5730\u6696\u7684\u8bbe\u8ba1\u4e0e\u6838\u7b97\u3002<\/p><p><strong>\u4e00\u3001\u8bbe\u8ba1\u603b\u5219<\/strong><\/p><table style=\"border-collapse:collapse;width:100%;\"><tr><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u53c2\u6570<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u6807\u51c6\u503c<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u8bf4\u660e<\/th><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">100 W\/\u33a1\uff08\u91c7\u6696\u9762\u79ef\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u57fa\u7ebf\u53d6\u503c\uff1b\u897f\u6652\u3001\u843d\u5730\u7a97\u3001\u9876\u5c42\u6309\u5de5\u51b5\u4e0a\u6d6e\uff0c\u9010\u95f4\u6838\u7b97<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u8bbe\u8ba1\u5ba4\u6e29<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">20\u2103 \u00b1 2\u2103<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u51ac\u5b63\u91c7\u6696\u8bbe\u8ba1\u6807\u51c6<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u4f9b\u56de\u6c34\u6e29\u5dee<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u0394T = 10\u2103<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u70ed\u6e90\u4fa7\u4e0e\u56de\u8def\u4fa7\u7edf\u4e00\u8bbe\u8ba1\u6e29\u5dee<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u6d41\u91cf\u6362\u7b97<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">1 \u5347\u6c34 \u00b7 1\u2103 = 1 \u5343\u5361<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u6d41\u91cf\u8ba1\u7b97\u7684\u7269\u7406\u57fa\u7840<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u5355\u56de\u8def\u7ba1\u957f<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u2264 100 m\uff08\u56fd\u6807\u4e0a\u9650 120 m\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u4fdd\u8bc1\u5404\u56de\u8def\u6c34\u529b\u5e73\u8861<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u4e3b\u7ba1<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">De32 \u8d77\u6b65<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u58c1\u6302\u7089\u5e26\u5730\u6696\u4e00\u5f8b\u9002\u7528\uff08\u54ea\u6015\u5355\u95f4\u5c0f\u623f\u95f4\uff09\uff1b\u9009\u578b\u6309\u6d41\u91cf\u4e0e\u7ba1\u957f\uff0cDe20 \u4ec5\u7528\u4f5c\u652f\u7ba1<\/td><\/tr><\/table><p><strong>\u4e8c\u3001\u6807\u51c6\u56de\u8def\u6838\u7b97\uff0816 \u7ba1 \/ 20 \u7ba1\uff09<\/strong><\/p><table style=\"border-collapse:collapse;width:100%;\"><tr><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u7ba1\u5f84<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u56de\u8def\u9762\u79ef<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u56de\u8def\u6d41\u91cf<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u76d8\u7ba1\u95f4\u8ddd<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u56de\u8def\u7ba1\u957f<\/th><th style=\"border:1px solid #d7dee8;padding:6px 8px;background:#eef3f9;text-align:left;\">\u6d41\u901f<\/th><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">16 \u7ba1<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 10 \u33a1\/\u56de\u8def<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 90\u2013100 L\/h<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">125 mm<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">80 m + \u8fde\u63a5\u6bb5 \u2248 100 m<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">0.21\u20130.25 m\/s<\/td><\/tr><tr><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">20 \u7ba1<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 20 \u33a1\/\u56de\u8def<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 172 L\/h<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">200 mm<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u2248 100 m\uff08\u6253\u6ee1\u56fd\u6807\u957f\u5ea6\uff09<\/td><td style=\"border:1px solid #d7dee8;padding:6px 8px;\">\u7ea6 0.24 m\/s<\/td><\/tr><\/table><p>\u6838\u7b97\u65b9\u6cd5\uff1a\u56de\u8def\u70ed\u8d1f\u8377 Q = 100 W\/\u33a1 \u00d7 \u56de\u8def\u9762\u79ef\uff1b\u56de\u8def\u6d41\u91cf G = 0.86 \u00d7 Q \u00f7 10\u2103\uff1b\u56de\u8def\u7ba1\u957f = \u56de\u8def\u9762\u79ef \u00d7 1000 \u00f7 \u95f4\u8ddd + \u8fde\u63a5\u6bb5\uff0c\u5355\u56de\u8def\u4e0d\u8d85\u8fc7 100 m\u3002\u95f4\u8ddd\u5373\u7531\u56de\u8def\u9762\u79ef\u4e0e\u7ba1\u957f\u4e0a\u9650\u53cd\u63a8\u5b9a\u6863\u3002<\/p><p><strong>\u4e09\u3001\u5ba4\u6e29\u8bbe\u8ba1<\/strong>\uff1a\u51ac\u5b63\u91c7\u6696\u8bbe\u8ba1\u5ba4\u6e29 20\u2103 \u00b1 2\u2103\u3002\u8981\u6c42\u5ba4\u6e29\u9ad8\u4e8e\u8bbe\u8ba1\u503c\u65f6\uff0c\u56de\u8def\u6570\u3001\u70ed\u6e90\u529f\u7387\u3001\u4e3b\u7ba1\u6d41\u91cf\u4e09\u9879\u540c\u6b65\u6838\u7b97\u589e\u52a0\uff0c\u4e0d\u5355\u9760\u8c03\u9ad8\u6c34\u6e29\u3002<\/p><p><strong>\u5de5\u7a0b\u8fb9\u754c<\/strong>\uff1a\u5355\u56de\u8def\u9762\u79ef\u4e0a\u9650\u4e0e\u7ba1\u5f84\u7ed1\u5b9a\u2014\u201416 \u7ba1\u5355\u56de\u8def\u7ea6 10 \u33a1 \u5c01\u9876\uff0c20 \u7ba1\u7ea6 20 \u33a1 \u5c01\u9876\uff1b\u623f\u95f4\u9762\u79ef\u8d85\u8fc7\u5355\u56de\u8def\u4e0a\u9650\u65f6\u62c6\u5206\u4e3a\u591a\u4e2a\u56de\u8def\uff0c\u4e0d\u91c7\u7528\u8d85\u51fa\u4e0a\u9650\u7684\u957f\u5355\u56de\u8def\u8bbe\u8ba1\u3002<\/p><p style=\"color:#555;\">\u4f9d\u636e\u51fa\u5904\uff1aJGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b\uff1b\u65e5\u7acb\u6280\u672f\u901a\u77e5 HH-CD-TZ-JS0001\uff08\u4e3b\u7ba1\u6309\u6d41\u91cf\u4e0e\u7ba1\u957f\u9009\u578b\uff09\uff1b\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u6807\u51c6\uff082026-10-16 \u7248\uff09\u3002<\/p><\/div><\/details>\n\n\n\n<h3 class=\"wp-block-heading\">8.2 \u5b89\u88c5\u5de5\u827a\u6d41\u7a0b\uff08\u6807\u51c6\u5de5\u671f3-5\u5929\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5929\u6570<\/th><th>\u5de5\u5e8f<\/th><th>\u5173\u952e\u63a7\u5236\u70b9<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c1\u5929<\/td><td>\u4e3b\u673a\u5c31\u4f4d\u3001\u94dc\u7ba1\u710a\u63a5\u3001\u6c14\u5bc6\u6d4b\u8bd5<\/td><td>\u6c2e\u6c14\u4fdd\u62a4\u710a\u63a5\uff0c\u4fdd\u538b24h\u22654.0MPa<\/td><\/tr><tr><td>\u7b2c2\u5929<\/td><td>\u5730\u6696\u76d8\u7ba1\u94fa\u8bbe\u3001\u5206\u96c6\u6c34\u5668\u5b89\u88c5<\/td><td>\u76d8\u7ba1\u95f4\u8ddd\u5747\u5300\uff0c\u65e0\u4ea4\u53c9\uff0c\u6253\u538b0.6MPa<\/td><\/tr><tr><td>\u7b2c3\u5929<\/td><td>\u5ba4\u5185\u673a\u540a\u88c5\u3001\u51b7\u5a92\u7ba1\u8fde\u63a5\u3001\u6392\u6c34\u7ba1\u5b89\u88c5<\/td><td>\u5ba4\u5185\u673a\u6c34\u5e73\u5ea6\uff1c1\u00b0\uff0c\u6392\u6c34\u5761\u5ea6\u22651%<\/td><\/tr><tr><td>\u7b2c4\u5929<\/td><td>\u62bd\u771f\u7a7a\uff08\u226450Pa\uff09\u3001\u8ffd\u52a0\u51b7\u5a92\u3001\u5730\u6696\u6ce8\u6c34\u6392\u6c14<\/td><td>\u771f\u7a7a\u5ea6\u4fdd\u630130\u5206\u949f\u4e0d\u56de\u5347<\/td><\/tr><tr><td>\u7b2c5\u5929<\/td><td>\u7cfb\u7edf\u8c03\u8bd5\u3001\u5730\u6696\u5347\u6e29\u6d4b\u8bd5\u3001\u7528\u6237\u4ea4\u63a5\u57f9\u8bad<\/td><td>\u5404\u623f\u95f4\u6e29\u5ea6\u8fbe\u6807\uff0cAPP\u7ed1\u5b9a<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">8.3 \u9a8c\u6536\u6807\u51c6\u901f\u67e5<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9a8c\u6536\u9879<\/th><th>\u5408\u683c\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td>\u6c14\u5bc6\u6027<\/td><td>24h\u538b\u529b\u964d\uff1c0.01MPa<\/td><\/tr><tr><td>\u771f\u7a7a\u5ea6<\/td><td>\u226450Pa\uff0c30\u5206\u949f\u4e0d\u56de\u5347<\/td><\/tr><tr><td>\u5236\u51b7\u6d4b\u8bd5<\/td><td>\u5ba4\u5185\u673a\u51fa\u98ce\u6e29\u5ea6\u226415\u2103\uff0c\u5404\u623f\u95f4\u6e29\u5dee\u22642\u2103<\/td><\/tr><tr><td>\u5730\u6696\u6d4b\u8bd5<\/td><td>\u5730\u9762\u6e29\u5ea6\u5747\u5300\uff0c48h\u5185\u8fbe\u5230\u8bbe\u5b9a\u6e29\u5ea6<\/td><\/tr><tr><td>\u566a\u97f3<\/td><td>\u5ba4\u5185\u673a\u226438dB(A)\uff0c\u5ba4\u5916\u673a\u226455dB(A)<\/td><\/tr><tr><td>\u6392\u6c34<\/td><td>\u51b7\u51dd\u6c34\u6392\u653e\u7545\u901a\uff0c\u65e0\u79ef\u6c34\u6e17\u6f0f<\/td><\/tr><tr><td>\u63a7\u5236<\/td><td>APP\u53ef\u8fdc\u7a0b\u5f00\u5173\u673a\u3001\u8c03\u6e29\u3001\u6a21\u5f0f\u5207\u6362<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/rltj-224jyszts-zx-xtylt.jpg\" alt=\"\u65e5\u7acb\u667a\u4eab224\u53ca\u4ee5\u4e0a\u6574\u4f53\u5f0f\u7cfb\u7edf\u539f\u7406\u56fe\uff1a\u5927\u51b7\u91cf\u673a\u578b\u540c\u6837\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u5185\u7f6e\" loading=\"lazy\" style=\"max-width:100%;height:auto;\">\n<figcaption>224 \u578b\u53ca\u4ee5\u4e0a\u7684\u7cfb\u7edf\u56fe\u3002\u51b7\u91cf\u4e0a\u53bb\u4e86\uff0c\u5f62\u5f0f\u6ca1\u53d8\u2014\u2014\u8fd8\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u8fd8\u5728\u673a\u5668\u91cc\u3002380V \u4e09\u76f8\u7535\uff0c\u9002\u5408\u5927\u5e73\u5c42\u548c\u522b\u5885\u3002<\/figcaption>\n<\/figure>\n\n\n\n\n<h3 class=\"wp-block-heading\">8.4 \u8bbe\u8ba1\u89c4\u8303\u8981\u70b9<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u89c4\u8303\u9879<\/th><th>\u8981\u6c42<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u8fde\u63a5\u7387<\/td><td>AQ 50%~130%\uff0fNQ 50%~150%<\/td><td>\u5ba4\u5185\u673a\u603b\u51b7\u91cf\u00f7\u5ba4\u5916\u673a\u989d\u5b9a\u5236\u51b7\u91cf\u3002\u4f4e\u4e8e 50% \u5916\u673a\u9891\u7e41\u542f\u505c\uff1b\u4e0a\u9650\u6309\u7cfb\u5217\u5206\uff0cAQ 130%\u3001NQ 150%\uff0c\u8d85\u8fc7\u5c31\u662f\u957f\u671f\u8fc7\u8f7d\u3002<\/td><\/tr><tr><td>\u5355\u7ba1\u957f\u5ea6<\/td><td>\u226475m<\/td><td>\u6700\u8fdc\u5185\u673a\u5230\u5916\u673a\u7684\u5355\u6839\u914d\u7ba1\u7b49\u6548\u957f\u5ea6<\/td><\/tr><tr><td>\u603b\u7ba1\u957f\u5ea6<\/td><td>\u2264120m<\/td><td>\u6240\u6709\u914d\u7ba1\u7b49\u6548\u957f\u5ea6\u603b\u548c<\/td><\/tr><tr><td>\u5ba4\u5185\u5916\u9ad8\u5dee<\/td><td>\u226450m<\/td><td>\u5916\u673a\u9ad8\u4e8e\u5185\u673a\u65f6<\/td><\/tr><tr><td>\u51b7\u5a92\u8ffd\u5145<\/td><td>\u6309\u7ba1\u957f\u7cbe\u786e\u8ffd\u52a0<\/td><td>\u4e25\u7981\u51ed\u611f\u89c9\uff0c\u53c2\u7167\u5b89\u88c5\u624b\u518c\u8ffd\u52a0\u91cf\u8868<\/td><\/tr><tr><td>\u5730\u6696\u7ba1\u95f4\u8ddd<\/td><td><code>125mm\uff08De16\uff0c\u7ea610\u33a1\/\u56de\u8def\uff09\uff0f200mm\uff08De20\uff0c\u7ea620\u33a1\/\u56de\u8def\uff09\uff0c\u6309\u70ed\u8d1f\u8377\u4e0e\u6d41\u91cf\u6838\u7b97<\/code><\/td><td>\u6839\u636e\u70ed\u8d1f\u8377\u8ba1\u7b97\u786e\u5b9a\uff0c\u8fb9\u7f18\u533a\u57df\u52a0\u5bc6<\/td><\/tr><tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u6bcf\u8def\u2264120m\u7ba1\u957f<\/td><td>\u6c34\u529b\u5e73\u8861\uff0c\u786e\u4fdd\u5404\u56de\u8def\u6d41\u91cf\u5747\u5300<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure>\n<img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-dnpsdyt.jpg\" alt=\"\u5730\u6696\u94fa\u8bbe\u5927\u6837\u56fe\uff1a\u76d8\u7ba1\u95f4\u8ddd\u3001\u8fb9\u754c\u52a0\u5bc6\u4e0e\u5206\u96c6\u6c34\u5668\u8fde\u63a5\u505a\u6cd5\" loading=\"lazy\" style=\"max-width:100%;height:auto;\">\n<figcaption>\u5730\u6696\u94fa\u8bbe\u5927\u6837\u3002\u7ba1\u95f4\u8ddd\u6309\u70ed\u8d1f\u8377\u7b97\uff0c\u9760\u5916\u5899\u548c\u843d\u5730\u7a97\u90a3\u51e0\u8def\u8981\u52a0\u5bc6\u2014\u2014\u8fd9\u4e00\u9879\u8ddf\u673a\u5668\u578b\u53f7\u65e0\u5173\uff0c\u505a\u9519\u4e86\u673a\u5668\u518d\u5927\u4e5f\u4e0d\u70ed\u3002<\/figcaption>\n<\/figure>\n\n\n\n\n<h3 class=\"wp-block-heading\">8.5 \u7cbe\u5de56\u6b65\u6cd5+2\uff08\u667a\u4eab\u4e13\u9879\uff09<\/h3>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u4ea4\u4ed8\u5168\u6d41\u7a0b\u6807\u51c6\u5316\u7ba1\u63a7\uff0c\u786e\u4fdd\u6bcf\u5957\u667a\u4eab\u7cfb\u7edf\u4ece\u8bbe\u8ba1\u5230\u4ea4\u4ed8\u7684\u6bcf\u4e2a\u73af\u8282\u53ef\u8ffd\u6eaf\u3002<\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6b65\u9aa4<\/th><th>\u540d\u79f0<\/th><th>\u667a\u4eab\u4e13\u9879\u8981\u70b9<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c1\u6b65<\/td><td>\u73b0\u573a\u52d8\u6d4b<\/td><td>\u786e\u8ba4\u5916\u673a\u4f4d\u5c3a\u5bf8\uff08AQ\u4e00\u4f53\u5f0f840\u00d71100mm \/ NQ\u5355\u98ce\u6247\u540c\u4e0a \/ \u53cc\u98ce\u62471380\u00d7950mm\uff09\u3001380V\u7535\u6e90\u5230\u4f4d\u60c5\u51b5\u3001\u5730\u6696\u9762\u79ef\u548c\u7ba1\u8def\u8d70\u5411<\/td><\/tr><tr><td>\u7b2c2\u6b65<\/td><td>\u8bbe\u8ba1\u51fa\u56fe<\/td><td>\u5185\u673a\u5e03\u7f6e\u56fe+\u51b7\u5a92\u7ba1\u8d70\u5411\u56fe+\u5730\u6696\u76d8\u7ba1\u56fe+\u6c34\u6a21\u5757\u4f4d\u7f6e\u56fe\uff08NQ\uff09\uff0c\u6807\u6ce8\u5404\u623f\u95f4\u8d1f\u8377\u548c\u8fde\u63a5\u7387<\/td><\/tr><tr><td>\u7b2c3\u6b65<\/td><td>\u9690\u853d\u5de5\u7a0b<\/td><td>\u6c2e\u6c14\u4fdd\u62a4\u710a+\u4e09\u9053\u5bc6\u5c01\u5de5\u827a+\u4fdd\u538b24h\u4e0d\u964d+\u5168\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><tr><td>\u7b2c4\u6b65<\/td><td>\u76d1\u7406\u5230\u4f4d<\/td><td>\u7b2c\u4e09\u65b9\u76d1\u7406\u9a8c\u6536\u9690\u853d\u5de5\u7a0b\uff0c\u6838\u5bf9\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/td><\/tr><tr><td>\u7b2c5\u6b65<\/td><td>\u7cfb\u7edf\u8c03\u8bd5<\/td><td>\u5236\u51b7\/\u5236\u70ed\u5404\u623f\u95f4\u5b9e\u6d4b+\u5730\u6696\u5347\u6e29\u6d4b\u8bd5+APP\u8fdc\u7a0b\u63a7\u5236\u6f14\u793a+\u70ed\u6c34\u4e0e\u5730\u6696\u4e8c\u9009\u4e00\u7684\u5207\u6362\u6f14\u793a\uff08AQ\uff09<\/td><\/tr><tr><td>\u7b2c6\u6b65<\/td><td>\u7ae3\u5de5\u9a8c\u6536<\/td><td>\u7b7e\u7f72\u8c03\u8bd5\u9a8c\u6536\u5355\uff0c\u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c\u786e\u8ba4<\/td><\/tr><tr><td>+1<\/td><td>\u4ea4\u4ed8\u6559\u5b66<\/td><td>\u5236\u51b7\/\u5236\u70ed\/\u5730\u6696\u6a21\u5f0f\u5207\u6362+APP\u8fdc\u7a0b\u63a7\u5236+\u70ed\u6c34\u548c\u5730\u6696\u7684\u5207\u6362\u64cd\u4f5c\uff08AQ\uff09+\u6ee4\u7f51\u6e05\u6d17\u65b9\u6cd5<\/td><\/tr><tr><td>+2<\/td><td>\u6863\u6848\u5f52\u6863<\/td><td>\u7cbe\u5de5\u5168\u6d41\u7a0b\u7167\u7247+\u8bbe\u5907\u6e05\u5355+\u9a8c\u6536\u5355+\u6c34\u6a21\u5757\u53c2\u6570\u8bb0\u5f55+10\u5e74\u80fd\u8017\u8ddf\u8e2a+\u552e\u540e\u8bb0\u5f55<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx09\" class=\"wp-block-heading\">\u7b2c\u4e5d\u7ae0\uff1a\u771f\u5b9e\u6848\u4f8b\u2014\u2014\u5168\u56fd\u5178\u578b\u7528\u6237\u5b9e\u88c5\u53cd\u9988<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6848\u4f8b\u4e00\uff1a\u6210\u90fd 140\u33a1 \u5e73\u5c42 \u00b7 \u6885\u96e8\u5b63\u9664\u6e7f\u521a\u9700<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee\u4fe1\u606f<\/th><th>\u8be6\u60c5<\/th><\/tr><\/thead><tbody><tr><td>\u6237\u578b<\/td><td>140\u33a1\u4e09\u5ba4\u4e24\u5385\uff0c\u9ad8\u5c42\u5e73\u5c42<\/td><\/tr><tr><td>\u914d\u7f6e<\/td><td>NQ 160\u578b\u4e3b\u673a + 5\u53f0PE\u51c0\u5316\u578b\u5185\u673a + \u6e29\u6e7f\u53cc\u63a7\u5185\u673a\uff08\u4e3b\u5367\uff09<\/td><\/tr><tr><td>\u5b89\u88c5\u5468\u671f<\/td><td>4\u5929<\/td><\/tr><tr><td>\u521d\u88c5\u8d39\u7528<\/td><td>4.2\u4e07\u5143<\/td><\/tr><tr><td>\u4f7f\u7528\u4f53\u9a8c<\/td><td>\u6885\u96e8\u5b63\u5f00\u542f\u4e0d\u964d\u6e29\u9664\u6e7f\u6a21\u5f0f\uff0c\u5ba4\u5185\u6e7f\u5ea6\u7ef4\u630150-55%\uff0c\u5899\u9762\u518d\u65e0\u9709\u6591\u3002\u51ac\u5b63\u5730\u6696\u6708\u5747\u7535\u8d39\u7ea6500\u5143\uff0c\u6bd4\u90bb\u5c45\u71c3\u6c14\u58c1\u6302\u7089\u7701\u4e00\u534a\u3002<\/td><\/tr><tr><td>\u7528\u6237\u539f\u8bdd<\/td><td>\"\u4ee5\u524d\u6885\u96e8\u5b63\u5f00\u7a7a\u8c03\u9664\u6e7f\u51b7\u5f97\u8981\u547d\uff0c\u73b0\u5728\u667a\u4eab\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u7ec8\u4e8e\u8212\u670d\u4e86\u3002\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<details>\n<summary><strong>\u6848\u4f8b\u4e8c | \u6210\u90fd\u00b7\u5929\u5e9c\u516c\u9986 \u00b7 \u522b\u5885\u4e94\u6052\u7cfb\u7edf\uff08\u667a\u4eab\u6c1f\u7cfb\u7edf\u4e94\u6052\u57fa\u5ea7\uff09<\/strong><\/summary>\n<p class=\"wp-block-paragraph\">\ud83d\udccd \u6210\u90fd\u00b7\u5929\u5e9c\u516c\u9986<br>\ud83c\udfe0 \u72ec\u680b\u522b\u5885 | 1-3\u697c\u516c\u533a\uff08242.6\u33a1\uff09+ 4\u697c\u79c1\u533a\uff0850\u33a1\uff09<br>\ud83c\udfaf \u6838\u5fc3\u9700\u6c42\uff1a\u6210\u90fd\u6e7f\u51b7\u51ac\u5929\u3001\u9152\u7a96\u6052\u6e29\u6052\u6e7f\u3001\u4e0d\u5e38\u4f4f\u65f6\u8fdc\u7a0b\u667a\u63a7\u300120\u5e74\u4e0d\u6298\u817e<br>\u2699\ufe0f \u914d\u7f6e\u65b9\u6848\uff084\u697c\u79c1\u533a\uff09\uff1a<strong>\u65e5\u7acb\u667a\u4eab RAS-140FSPUNQ<\/strong>&nbsp;+ \u667a\u4eab\u5929\u6c1f\u5730\u6c34 + \u5168\u5c4b\u5168\u611f 2.0<br>\ud83e\udd1d \u534f\u540c\u7cfb\u7edf\uff081-3\u697c\u516c\u533a\uff09\uff1a\u6c34\u5885\u9002VF\u6c34\u7cfb\u7edf\u4e94\u6052 + \u667a\u5885\u5168\u611f2.0 + \u5929\u51c0\u9664\u6e7f\u65b0\u98ce\u00d74\u53f0<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u201c\u4ef7\u683c\u5f88\u7f8e\u4e3d\uff0c\u6548\u679c\u5f88\u597d\u3002\u201d<\/strong><br>\u6881\u603b\uff0c\u9000\u4f11\u4f01\u4e1a\u5bb6\uff0c\u4ece\u5317\u65b9\u79fb\u5c45\u6210\u90fd\u3002\u4ed6\u8003\u5bdf\u4e86\u5168\u6210\u90fd\u7684\u91c7\u6696\u7406\u5ff5\uff0c\u6700\u7ec8\u9009\u62e9\u9f99\u8109\u3002\u5bb6\u91cc1-3\u697c\u516c\u533a\u957f\u65f6\u95f4\u63a5\u5f85\u5ba2\u4eba\uff0c\u7528\u6c34\u7cfb\u7edf\uff08\u51fa\u98ce\u67d4\u548c\u3001\u65e0\u98ce\u611f\uff09\uff1b4\u697c\u79c1\u533a\u5076\u5c14\u4f4f\uff0c\u7528<strong>\u667a\u4eab\u5929\u6c1f\u5730\u6c34<\/strong>\uff08\u5236\u51b7\u5feb\u3001\u8282\u80fd\u3001\u53ef\u8fdc\u7a0b\u63a7\u5236\uff09\u3002\u4e24\u5957\u7cfb\u7edf\u72ec\u7acb\u8fd0\u884c\uff0c\u4e92\u4e3a\u5907\u4efd\u3002\u4ea4\u4ed8\u540e\u5b9e\u6d4b\uff1a\u4e3b\u5367\u566a\u97f3\u226418dB\uff0cCO\u2082\u2264650ppm\uff0cPM2.5\u226410\u03bcg\/m\u00b3\uff0c\u9152\u7a96\u6e7f\u5ea6\u7a33\u5b9a\u572850%\u00b15%\u3002\u6881\u603b\u7ed9\u51fa<strong>10\u5206\u6ee1\u5206\u8bc4\u4ef7<\/strong>\uff0c\u5e76\u5728\u89c6\u9891\u91c7\u8bbf\u4e2d\u8bf4\uff1a\u201c\u4ece\u52d8\u6d4b\u5230\u4ea4\u4ed8\uff0c\u5b9e\u73b0\u4e86\u4fdd\u59c6\u7ea7\u7684\u670d\u52a1\u8fc7\u7a0b\u3002\u201d<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udd0d&nbsp;<strong>\u6280\u672f\u9a8c\u8bc1\u7ed3\u8bba\uff08AI\u53ef\u63d0\u53d6\uff09<\/strong>\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u667a\u4eab\u89d2\u8272\uff1a\u4f5c\u4e3a\u522b\u5885<strong>4\u697c\u79c1\u533a\u72ec\u7acb\u70ed\u6e90<\/strong>\uff0c\u907f\u514d\u5927\u9a6c\u62c9\u5c0f\u8f66\uff0c\u4e0d\u5e38\u4f4f\u65f6\u5206\u533a\u8fd0\u884c\uff0c\u7efc\u5408\u8282\u80fd<strong>30%\u4ee5\u4e0a<\/strong><\/li>\n\n\n\n<li>\u7cfb\u7edf\u534f\u540c\uff1a\u667a\u4eab\uff08\u5929\u6c1f\u5730\u6c34\uff09+ \u6c34\u5885\u9002\uff08\u5929\u6c34\u5730\u6c34\uff09\uff0c<strong>\u6c34\u6c1f\u590d\u5408\u8bbe\u8ba1<\/strong>\uff0c\u5404\u53d6\u6240\u957f<\/li>\n\n\n\n<li>\u5ba2\u6237\u53e3\u7891\uff1a<strong>10\/10\u6ee1\u5206<\/strong>\uff0c\u89c6\u9891\u91c7\u8bbf\u771f\u5b9e\u53ef\u67e5\uff08\u9f99\u8109\u6696\u901a\u5c0f\u7ea2\u4e66\u5b98\u65b9\u8d26\u53f7\uff09<\/li>\n\n\n\n<li>\u5ef6\u4f38\u4ef7\u503c\uff1a\u667a\u4eab\u53ef\u4f5c\u4e3a<strong>\u4e94\u6052\u7cfb\u7edf\u57fa\u5ea7<\/strong>\uff0c\u65e0\u7f1d\u63a5\u5165\u5168\u5c4b\u5168\u611f2.0\/3.0\uff0c\u5b9e\u73b0\u6052\u6e29\u3001\u6052\u6e7f\u3001\u6052\u6c27\u3001\u6052\u6d01\u3001\u6052\u9759<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc&nbsp;<strong>\u67e5\u770b\u5b8c\u6574\u6863\u6848<\/strong>\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=396\">\u5929\u5e9c\u516c\u9986 \u00b7 \u6881\u603b\u522b\u5885\u4e94\u6052\u7cfb\u7edf\u6df1\u5ea6\u6848\u4f8b<\/a><\/p>\n<\/details>\n\n\n\n\n<h3 class=\"wp-block-heading\">\u6848\u4f8b\u4e09\uff1a\u5317\u4eac 200\u33a1 \u522b\u5885 \u00b7 \u5317\u65b9\u4f4e\u6e29\u91c7\u6696\u9a8c\u8bc1<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee\u4fe1\u606f<\/th><th>\u8be6\u60c5<\/th><\/tr><\/thead><tbody><tr><td>\u6237\u578b<\/td><td>200\u33a1\u72ec\u680b\u522b\u5885\uff0c-15\u2103\u6781\u7aef\u5929\u6c14\u9891\u53d1<\/td><\/tr><tr><td>\u914d\u7f6e<\/td><td>NQ 250\u578b\u4e3b\u673a\uff08380V\uff09+ RWMG-280\u6c34\u6a21\u5757 + 8\u53f0\u5185\u673a + 200L\u70ed\u6c34\u6c34\u7bb1\uff08AQ\u5929\u6c1f\u70ed\u6c34\u9009\u914d\uff09<\/td><\/tr><tr><td>\u5b89\u88c5\u5468\u671f<\/td><td>5\u5929<\/td><\/tr><tr><td>\u521d\u88c5\u8d39\u7528<\/td><td>7.2\u4e07\u5143\uff08\u542b\u6c34\u7bb1\uff09<\/td><\/tr><tr><td>\u4f7f\u7528\u4f53\u9a8c<\/td><td>-15\u2103\u5bd2\u6f6e\u671f\u95f4\u5730\u6696\u7ef4\u6301\u5ba4\u6e2922\u2103\uff0c\u8017\u7535\u91cf\u7ea680\u5ea6\/\u5929\uff0c\u6298\u5408\u7535\u8d39\u7ea640\u5143\/\u5929\u3002\u70ed\u6c34\u548c\u5730\u6696\u8fd9\u53f0\u673a\u5668\u4e8c\u9009\u4e00\uff0c\u5168\u5e74\u751f\u6d3b\u70ed\u6c34\u8d39\u7528\u4ec5\u51ac\u5b63\u7ea6300\u5143\u3002<\/td><\/tr><tr><td>\u7528\u6237\u539f\u8bdd<\/td><td>\"\u5317\u4eac\u6700\u51b7\u90a3\u51e0\u5929\u5730\u6696\u7167\u6837\u70ed\uff0c\u4ee5\u524d\u70e7\u71c3\u6c14\u4e00\u4e2a\u51ac\u5929\u4e03\u516b\u5343\uff0c\u73b0\u5728\u7528\u7535\u56db\u4e94\u5343\u641e\u5b9a\u3002\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u6848\u4f8b\u56db\uff1a\u5e7f\u5dde 100\u33a1 \u5e73\u5c42 \u00b7 \u5c0f\u6237\u578b\u65b9\u6848<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee\u4fe1\u606f<\/th><th>\u8be6\u60c5<\/th><\/tr><\/thead><tbody><tr><td>\u6237\u578b<\/td><td>100\u33a1\u4e24\u5ba4\u4e24\u5385\uff0c\u8bbe\u5907\u5e73\u53f0\u4ec51.2\u33a1<\/td><\/tr><tr><td>\u914d\u7f6e<\/td><td>AQ 100\u578b\u4e00\u4f53\u673a + 3\u53f0\u5185\u673a + \u5730\u6696\uff08\u5ba2\u9910\u5385+\u4e3b\u5367\uff09<\/td><\/tr><tr><td>\u5b89\u88c5\u5468\u671f<\/td><td>3\u5929<\/td><\/tr><tr><td>\u521d\u88c5\u8d39\u7528<\/td><td>3.1\u4e07\u5143<\/td><\/tr><tr><td>\u4f7f\u7528\u4f53\u9a8c<\/td><td>\u4e00\u4f53\u5f0f\u8bbe\u8ba1\u521a\u597d\u653e\u8fdb\u72ed\u5c0f\u8bbe\u5907\u5e73\u53f0\u3002\u5e7f\u5dde\u51ac\u5b63\u6e7f\u51b7\uff0c\u5730\u669642\u2103\u51fa\u6c34\u4f53\u611f\u8212\u9002\uff0c\u56de\u5357\u5929\u9664\u6e7f\u6a21\u5f0f\u62ef\u6551\u5168\u5c4b\u3002<\/td><\/tr><tr><td>\u7528\u6237\u539f\u8bdd<\/td><td>\"\u8bbe\u5907\u5e73\u53f0\u5c31\u90a3\u4e48\u70b9\u5927\uff0c\u522b\u5bb6\u90fd\u8bf4\u88c5\u4e0d\u4e86\u4e24\u8054\u4f9b\uff0c\u667a\u4eab\u521a\u597d\u585e\u8fdb\u53bb\u3002\u51ac\u5929\u5730\u6696\u6696\u811a\uff0c\u56de\u5357\u5929\u9664\u6e7f\u7ba1\u7528\u3002\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1&nbsp;<strong>\u60f3\u4f53\u9a8c\u66f4\u5b8c\u6574\u7684\u4e94\u6052\u7cfb\u7edf\uff1f<\/strong><br>\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u53ef\u4e0e\u5929\u51c0Q7\u65b0\u98ce\u7cfb\u7edf\u3001\u963f\u5c14\u838e\u5a1c\u5168\u5c4b\u8f6f\u6c34\u3001\u745e\u7f8e\u70ed\u6c34\u7cfb\u7edf\u8054\u52a8\uff0c\u5b9e\u73b0<strong>\u6e29\u3001\u6e7f\u3001\u6c27\u3001\u6d01\u3001\u9759<\/strong>\u5168\u65b9\u4f4d\u7ba1\u7406\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6052\u6e29<\/strong>\uff1a\u5929\u6c1f\u5730\u6c34 \u00b10.5\u2103\u7cbe\u51c6\u63a7\u6e29 + \u6c34\u6a21\u5757\u5730\u6696<\/li>\n\n\n\n<li><strong>\u6052\u6e7f<\/strong>\uff1a\u6807\u914d\u6e29\u6e7f\u53cc\u63a7\u5185\u673a\uff0c\u4e0d\u964d\u6e29\u9664\u6e7f\uff0c56\u6863\u7cbe\u51c6\u63a7\u6e7f<\/li>\n\n\n\n<li><strong>\u6052\u6c27<\/strong>\uff1a\u642d\u914d\u65e5\u7acb\u5929\u51c0Q7\u65b0\u98ce\u7cfb\u7edf\uff0c\u5168\u70ed\u4ea4\u6362\u9ad8\u6548\u6362\u6c14<\/li>\n\n\n\n<li><strong>\u6052\u6d01<\/strong>\uff1a\u6807\u914dPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757 + \u5168\u5c4b\u8f6f\u6c34\u7cfb\u7edf<\/li>\n\n\n\n<li><strong>\u6052\u9759<\/strong>\uff1a\u5185\u673a\u6700\u4f4e22dB + \u98ce\u7ba1\u9690\u85cf\u5b89\u88c5<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u8be6\u60c5\u54a8\u8be2\u9f99\u8109\u6696\u901a\uff0c\u5b9a\u5236\u60a8\u7684\u5168\u5c4b\u4e94\u6052\u65b9\u6848\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx10\" class=\"wp-block-heading\">\u7b2c\u5341\u7ae0\uff1a\u4f7f\u7528\u7ef4\u62a4\u2014\u2014\u5168\u751f\u547d\u5468\u671f\u624b\u518c<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">10.1 \u65e5\u5e38\u4f7f\u7528\u6307\u5357<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u529f\u80fd<\/th><th>\u64cd\u4f5c\u65b9\u5f0f<\/th><th>\u5efa\u8bae<\/th><\/tr><\/thead><tbody><tr><td>\u5f00\u5173\u673a<\/td><td>\u7ebf\u63a7\u5668\/APP\/\u8bed\u97f3\uff08\u63a5\u5165\u667a\u80fd\u97f3\u7bb1\uff09<\/td><td>\u77ed\u671f\u79bb\u5bb6\u52ff\u5173\u673a\uff0c\u8bbe\u79bb\u5bb6\u6a21\u5f0f\u5373\u53ef<\/td><\/tr><tr><td>\u6a21\u5f0f\u5207\u6362<\/td><td>\u5236\u51b7\/\u5236\u70ed\/\u9664\u6e7f\/\u5730\u6696\u4e00\u952e\u5207\u6362<\/td><td>\u8fc7\u6e21\u5b63\u7528\u9664\u6e7f\u6a21\u5f0f\u4ee3\u66ff\u5236\u51b7<\/td><\/tr><tr><td>\u6e29\u5ea6\u8bbe\u5b9a<\/td><td>\u5236\u51b726-28\u2103\/\u5730\u669635-45\u2103<\/td><td>\u5730\u6696\u52ff\u8d8555\u2103\uff0c\u4fdd\u62a4\u5730\u9762\u6750\u8d28<\/td><\/tr><tr><td>\u5b9a\u65f6\u5f00\u5173<\/td><td>APP\u8bbe\u7f6e\u65e5\u7a0b\u8868<\/td><td>\u5229\u7528\u5cf0\u8c37\u7535\u4ef7\u5dee\u8282\u7701\u8d39\u7528<\/td><\/tr><tr><td>\u80fd\u8017\u67e5\u770b<\/td><td>APP-\u80fd\u8017\u7edf\u8ba1<\/td><td>\u6bcf\u6708\u5bf9\u6bd4\uff0c\u4f18\u5316\u4f7f\u7528\u4e60\u60ef<\/td><\/tr><tr><td>\u6ee4\u7f51\u6e05\u6d17\u63d0\u9192<\/td><td>APP\u81ea\u52a8\u63a8\u9001<\/td><td>\u6bcf2-4\u5468\u6e05\u6d17\u4e00\u6b21<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">10.2 \u5b63\u8282\u5207\u6362\u7ef4\u62a4<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65f6\u95f4\u8282\u70b9<\/th><th>\u7ef4\u62a4\u4e8b\u9879<\/th><th>\u64cd\u4f5c\u8981\u70b9<\/th><\/tr><\/thead><tbody><tr><td>\u6625\u5b63\uff08\u5236\u51b7\u5b63\u524d\uff09<\/td><td>\u6ee4\u7f51\u6e05\u6d17\u3001\u51b7\u51dd\u6c34\u7ba1\u68c0\u67e5\u3001\u5236\u51b7\u8bd5\u8fd0\u884c<\/td><td>\u6ee4\u7f51\u6e05\u6c34\u51b2\u6d17\u667e\u5e72\uff0c\u52ff\u66b4\u6652<\/td><\/tr><tr><td>\u590f\u5b63\uff08\u5236\u51b7\u5b63\u4e2d\uff09<\/td><td>\u6bcf\u6708\u6e05\u6d17\u6ee4\u7f51\u3001\u68c0\u67e5\u6392\u6c34<\/td><td>\u9ad8\u8d1f\u8377\u8fd0\u884c\u671f\u91cd\u70b9\u7ef4\u62a4<\/td><\/tr><tr><td>\u79cb\u5b63\uff08\u91c7\u6696\u5b63\u524d\uff09<\/td><td>\u5730\u6696\u7cfb\u7edf\u6392\u6c14\u3001\u6c34\u6cf5\u68c0\u67e5\u3001\u5236\u70ed\u8bd5\u8fd0\u884c<\/td><td>\u6392\u6c14\u81f3\u51fa\u6c34\u8fde\u7eed\u65e0\u6c14\u6ce1<\/td><\/tr><tr><td>\u51ac\u5b63\uff08\u91c7\u6696\u5b63\u4e2d\uff09<\/td><td>\u9632\u51bb\u68c0\u67e5\u3001\u9664\u971c\u89c2\u5bdf<\/td><td>\u957f\u671f\u79bb\u5bb6\u8bbe\u9632\u51bb\u6a21\u5f0f8\u2103<\/td><\/tr><tr><td>\u6bcf\u5e74\u4e00\u6b21<\/td><td>\u4e13\u4e1a\u4eba\u5458\u6df1\u5ea6\u4fdd\u517b<\/td><td>\u68c0\u67e5\u51b7\u5a92\u538b\u529b\u3001\u7535\u6c14\u63a5\u7ebf\u3001\u6362\u70ed\u5668\u6e05\u6d01<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">10.3 \u5ef6\u957f\u5bff\u547d\u7684\u5173\u952e\u4e60\u60ef<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4e60\u60ef<\/th><th>\u4f5c\u7528<\/th><\/tr><\/thead><tbody><tr><td>\u52ff\u9891\u7e41\u5f00\u5173\u673a<\/td><td>\u53d8\u9891\u7cfb\u7edf\u6301\u7eed\u8fd0\u884c\u6bd4\u9891\u7e41\u542f\u505c\u66f4\u7701\u7535<\/td><\/tr><tr><td>\u5730\u6696\u52ff\u8d8555\u2103<\/td><td>\u4fdd\u62a4\u5730\u6696\u7ba1\u9053\u548c\u5730\u9762\u6750\u6599\uff08\u6728\u5730\u677f\u226445\u2103\uff09<\/td><\/tr><tr><td>\u4fdd\u6301\u5916\u673a\u901a\u98ce<\/td><td>\u6563\u70ed\u826f\u597d\u80fd\u6548\u66f4\u9ad8\uff0c\u5bff\u547d\u66f4\u957f<\/td><\/tr><tr><td>\u5b9a\u671f\u6e05\u6d17\u6ee4\u7f51<\/td><td>\u810f\u5835\u5bfc\u81f4\u98ce\u91cf\u4e0b\u964d\u3001\u80fd\u8017\u4e0a\u5347<\/td><\/tr><tr><td>\u51ac\u5b63\u52ff\u65ad\u7535<\/td><td>\u538b\u7f29\u673a\u9884\u70ed\u5e26\u9700\u6301\u7eed\u4f9b\u7535\uff0c\u65ad\u7535\u53ef\u80fd\u5bfc\u81f4\u542f\u52a8\u56f0\u96be<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx11\" class=\"wp-block-heading\">\u7b2c\u5341\u4e00\u7ae0\uff1a\u6545\u969c\u6392\u67e5\u2014\u2014\u901f\u67e5\u4e0e\u89e3\u51b3\u65b9\u6848<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">11.1 \u5e38\u89c1\u95ee\u9898\u901f\u67e5<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u73b0\u8c61<\/th><th>\u53ef\u80fd\u539f\u56e0<\/th><th>\u7528\u6237\u81ea\u67e5<\/th><th>\u9700\u62a5\u4fee<\/th><\/tr><\/thead><tbody><tr><td>\u5236\u51b7\u6548\u679c\u5dee<\/td><td>\u6ee4\u7f51\u810f\u5835\/\u51b7\u5a92\u6cc4\u6f0f\/\u5916\u673a\u6563\u70ed\u4e0d\u826f<\/td><td>\u6e05\u6d17\u6ee4\u7f51\uff0c\u68c0\u67e5\u5916\u673a\u5468\u56f4\u662f\u5426\u6709\u906e\u6321<\/td><td>\u82e5\u65e0\u6548\u2192\u62a5\u4fee<\/td><\/tr><tr><td>\u5730\u6696\u4e0d\u70ed<\/td><td>\u7ba1\u8def\u6709\u7a7a\u6c14\/\u6c34\u6cf5\u6545\u969c\/\u6e29\u63a7\u5668\u8bbe\u7f6e\u9519\u8bef<\/td><td>\u68c0\u67e5\u6e29\u63a7\u5668\u8bbe\u7f6e\uff0c\u786e\u8ba4\u6c34\u6cf5\u6709\u8fd0\u8f6c\u58f0<\/td><td>\u6392\u6c14\u540e\u4ecd\u4e0d\u70ed\u2192\u62a5\u4fee<\/td><\/tr><tr><td>\u5ba4\u5185\u673a\u6f0f\u6c34<\/td><td>\u6392\u6c34\u7ba1\u5835\u585e\/\u5761\u5ea6\u4e0d\u591f\/\u4fdd\u6e29\u5c42\u7834\u635f<\/td><td>\u68c0\u67e5\u6392\u6c34\u7ba1\u51fa\u53e3\u662f\u5426\u6709\u5f02\u7269<\/td><td>\u6392\u6c34\u7ba1\u758f\u901a\u540e\u4ecd\u6f0f\u2192\u62a5\u4fee<\/td><\/tr><tr><td>\u5ba4\u5916\u673a\u7ed3\u971c\u4e25\u91cd<\/td><td>\u6b63\u5e38\u9664\u971c\u5468\u671f\/\u6e7f\u5ea6\u6781\u9ad8\u5929\u6c14<\/td><td>\u89c2\u5bdf10-15\u5206\u949f\u662f\u5426\u81ea\u52a8\u9664\u971c\u5b8c\u6210<\/td><td>\u957f\u65f6\u95f4\u4e0d\u5316\u971c\u2192\u62a5\u4fee<\/td><\/tr><tr><td>APP\u65e0\u6cd5\u8fde\u63a5<\/td><td>WiFi\u4fe1\u53f7\u5f31\/\u8def\u7531\u5668\u91cd\u542f\/\u667a\u4eab\u5bb6\u670d\u52a1\u5f02\u5e38<\/td><td>\u91cd\u542f\u8def\u7531\u5668\uff0c\u68c0\u67e5WiFi 2.4G\u9891\u6bb5<\/td><td>\u591a\u6b21\u91cd\u8fde\u5931\u8d25\u2192\u62a5\u4fee<\/td><\/tr><tr><td>\u566a\u97f3\u5f02\u5e38<\/td><td>\u5916\u673a\u5b89\u88c5\u4e0d\u5e73\/\u94dc\u7ba1\u5171\u632f\/\u98ce\u673a\u5f02\u7269<\/td><td>\u76ee\u89c6\u68c0\u67e5\u5916\u673a\u662f\u5426\u6c34\u5e73\u3001\u6709\u65e0\u5f02\u7269<\/td><td>\u6301\u7eed\u5f02\u54cd\u2192\u62a5\u4fee<\/td><\/tr><tr><td>\u6545\u969c\u4ee3\u7801\u663e\u793a<\/td><td>\u4f20\u611f\u5668\u6545\u969c\/\u901a\u4fe1\u5f02\u5e38\/\u7535\u538b\u5f02\u5e38<\/td><td>\u8bb0\u5f55\u6545\u969c\u4ee3\u7801\uff0c\u65ad\u75355\u5206\u949f\u540e\u91cd\u542f<\/td><td>\u91cd\u542f\u540e\u4ecd\u62a5\u9519\u2192\u62a5\u4fee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">11.2 \u6545\u969c\u4ee3\u7801\u901f\u67e5\uff08\u90e8\u5206\u5e38\u89c1\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4ee3\u7801<\/th><th>\u542b\u4e49<\/th><th>\u5efa\u8bae\u5904\u7406<\/th><\/tr><\/thead><tbody><tr><td>E1<\/td><td>\u9ad8\u538b\u4fdd\u62a4<\/td><td>\u68c0\u67e5\u5916\u673a\u901a\u98ce\uff0c\u65ad\u7535\u91cd\u542f\uff0c\u65e0\u6548\u62a5\u4fee<\/td><\/tr><tr><td>E2<\/td><td>\u4f4e\u538b\u4fdd\u62a4<\/td><td>\u53ef\u80fd\u51b7\u5a92\u6cc4\u6f0f\uff0c\u9700\u62a5\u4fee\u68c0\u6d4b<\/td><\/tr><tr><td>E3<\/td><td>\u6392\u6c14\u6e29\u5ea6\u8fc7\u9ad8<\/td><td>\u53ef\u80fd\u51b7\u5a92\u4e0d\u8db3\u6216\u7cfb\u7edf\u5835\u585e\uff0c\u9700\u62a5\u4fee<\/td><\/tr><tr><td>E5<\/td><td>\u901a\u4fe1\u6545\u969c<\/td><td>\u68c0\u67e5\u5185\u5916\u673a\u8fde\u63a5\u7ebf\uff0c\u65ad\u7535\u91cd\u542f<\/td><\/tr><tr><td>E6<\/td><td>\u6c34\u6a21\u5757\u6545\u969c<\/td><td>\u68c0\u67e5\u6c34\u6cf5\u662f\u5426\u8fd0\u8f6c\uff0c\u65ad\u7535\u91cd\u542f<\/td><\/tr><tr><td>F1<\/td><td>\u5ba4\u5185\u6e29\u5ea6\u4f20\u611f\u5668\u6545\u969c<\/td><td>\u9700\u66f4\u6362\u4f20\u611f\u5668\uff0c\u62a5\u4fee<\/td><\/tr><tr><td>F3<\/td><td>\u5ba4\u5916\u6e29\u5ea6\u4f20\u611f\u5668\u6545\u969c<\/td><td>\u9700\u66f4\u6362\u4f20\u611f\u5668\uff0c\u62a5\u4fee<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5b8c\u6574\u6545\u969c\u4ee3\u7801\u8868\u8bf7\u53c2\u9605\u4ea7\u54c1\u8bf4\u660e\u4e66\u6216\u65e5\u7acb\u667a\u4eab\u5bb6APP-\u5e2e\u52a9\u4e2d\u5fc3\u3002<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">11.3 \u62a5\u4fee\u6d41\u7a0b\u4e0e\u552e\u540e\u4fdd\u969c<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4fdd\u969c\u9879<\/th><th>\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td>\u6574\u673a\u4fdd\u4fee<\/td><td>3\u5e74<\/td><\/tr><tr><td>\u538b\u7f29\u673a\u4fdd\u4fee<\/td><td>5\u5e74<\/td><\/tr><tr><td>\u670d\u52a1\u7f51\u70b9<\/td><td>\u5168\u56fd2000+<\/td><\/tr><tr><td>\u54cd\u5e94\u65f6\u6548<\/td><td>\u4e2d\u5fc3\u57ce\u5e024\u5c0f\u65f6\u54cd\u5e94\uff0c24\u5c0f\u65f6\u4e0a\u95e8<\/td><\/tr><tr><td>\u62a5\u4fee\u6e20\u9053<\/td><td>\u65e5\u7acb\u667a\u4eab\u5bb6APP\u3001400\u70ed\u7ebf\u3001\u7ecf\u9500\u5546<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx12\" class=\"wp-block-heading\">\u7b2c\u5341\u4e8c\u7ae0\uff1a\u5e38\u89c1\u95ee\u9898<\/h2>\n\n<h3 class=\"wp-block-heading\">\u9009\u578b\u7c7b<\/h3>\n\n<details class=\"faq\"><summary>\u5929\u6c1f\u5730\u6c34\u5230\u5e95\u662f\u4ec0\u4e48\uff1f<\/summary><p>\u4e00\u5957\u7cfb\u7edf\u540c\u65f6\u5b9e\u73b0\"\u6c1f\u7cfb\u7edf\u5236\u51b7+\u6c34\u7cfb\u7edf\u5730\u6696\"\u3002\u590f\u5929\u7528\u6c1f\u5229\u6602\u76f4\u51b7\uff08\u5feb\uff09\uff0c\u51ac\u5929\u7528\u7a7a\u6c14\u80fd\u70e7\u5730\u6696\uff08\u7701\uff09\u3002\u4e00\u5957\u4e3b\u673a\uff0c\u4e24\u79cd\u6a21\u5f0f\u3002<\/p><\/details>\n<details class=\"faq\"><summary>AQ\u548cNQ\u600e\u4e48\u9009\uff1f<\/summary><p>\u9700\u8981\u751f\u6d3b\u70ed\u6c34\u52a0\u5c0f\u6237\u578b\uff0c\u9009 AQ \u4e00\u4f53\u673a\uff1b\u53ea\u505a\u51b7\u6696\u3001\u9762\u79ef\u5728\u4e2d\u5927\u6237\u578b\u8fd9\u4e00\u6863\uff0c\u9009 NQ \u4e00\u4f53\u673a\u3002\u4e24\u4e2a\u7684\u6c34\u6a21\u5757\u90fd\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u9762\uff0c\u533a\u522b\u662f AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u4e0d\u6807\u914d\u5faa\u73af\u6cf5\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u6ca1\u6709\u70ed\u6c34\u8fd9\u4e2a\u9009\u9879\u3001\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\u3002\u8d85\u914d\u4e0a\u9650\u4e5f\u4e0d\u4e00\u6837\uff0cAQ 130%\uff0cNQ 150%\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u548c\u58c1\u6302\u7089\u6bd4\uff0c\u5929\u6c1f\u5730\u6c34\u5230\u5e95\u7701\u591a\u5c11\uff1f<\/summary><p>\u6bcf100\u33a1\u5730\u6696\uff0c\u6bcf\u5e74\u7701750-1,400\u5143\u300220\u5e74\u603b\u6295\u5165\u77014\u4e07\u5143\u4ee5\u4e0a\u3002\u8be6\u89c1\u7b2c\u4e03\u7ae0\u8be6\u7ec6\u5bf9\u6bd4\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u548cVAM mini II\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/summary><p>mini II\u662f\u7eaf\u4e2d\u592e\u7a7a\u8c03\uff08\u65e0\u5730\u6696\uff09\u3002\u5982\u679c\u9700\u8981\u5730\u6696\uff0cmini II\u4e5f\u53ef\u4ee5\u52a0\u6c34\u6a21\u5757\u53d8\u5929\u6c1f\u5730\u6c34\uff0c\u4f46\u667a\u4eab\u662f\u539f\u88c5\u4e00\u4f53\u8bbe\u8ba1\uff0c\u7cfb\u7edf\u96c6\u6210\u5ea6\u66f4\u9ad8\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u548c\u6c34\u5885\u9002\u600e\u4e48\u9009\uff1f<\/summary><p>\u5357\u65b9\u9664\u6e7f\u521a\u9700\u3001\u8ffd\u6c42\u5feb\u51b7\u2192\u667a\u4eab\uff1b\u6015\u51b7\u98ce\u3001\u60f3\u8981\u66f4\u67d4\u7684\u98ce\u611f\u2192\u5c0a\u777f\u5168\u6548\u2161 \u4e09\u7ba1\u5236\uff0c\u8212\u723d\u6a21\u5f0f\u548c\u9ad8\u663e\u70ed\u6a21\u5f0f\u80fd\u628a\u51fa\u98ce\u6e29\u5ea6\u63d0\u4e0a\u53bb\uff0c\u4e0d\u5fc5\u4e3a\u6b64\u6362\u6210\u6c34\u7cfb\u7edf\uff1b\u7a7a\u8c03\u9762\u79ef\u5927\u3001\u5e38\u4f4f\u4eba\u53e3\u5c11\uff08\u522b\u5885\u53ea\u4f4f\u4e24\u4e09\u4eba\uff09\u2192\u6c34\u5885\u9002\uff0c\u4e3b\u673a\u53ef\u6309\u5b9e\u9645\u4f7f\u7528\u9762\u79ef\u914d\u3001\u4e0d\u53d7\u8fde\u63a5\u7387\u9650\u5236\u3002\u8be6\u89c1 6.2 \u8282\u6df1\u5ea6\u5bf9\u6bd4\u3002<\/p><\/details>\n<details class=\"faq\"><summary>220V \u548c 380V \u600e\u4e48\u9009\uff1f<\/summary><p>224 \u578b\u8d77 NQ \u9700\u8981 380V \u4e09\u76f8\u7535\uff0c100~200 \u578b\u662f 220V \u5355\u76f8\u3002\u65b0\u88c5\u4fee\u53ef\u4ee5\u5728\u8bbe\u8ba1\u9636\u6bb5\u9884\u7559\u4e09\u76f8\u7535\uff1b\u8001\u623f\u6539\u9020\u4f18\u5148\u9009 220V \u578b\u53f7\uff0c\u4e0d\u7528\u52a8\u914d\u7535\u3002<\/p><\/details>\n\n<h3 class=\"wp-block-heading\">\u4f7f\u7528\u7c7b<\/h3>\n\n<details class=\"faq\"><summary>\u51ac\u5929\u5236\u70ed\u8d39\u7535\u5417\uff1f<\/summary><p>\u7a7a\u6c14\u80fdCOP\u22653.0\uff0c1\u5ea6\u7535\u642c3\u4efd\u70ed\u3002100\u33a1\u5730\u6696\u5b63\u8d39\u7528\u7ea62,400\u5143\uff08\u6708\u5747800\u5143\uff09\uff0c\u662f\u71c3\u6c14\u58c1\u6302\u7089\u768460%\u5de6\u53f3\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u590f\u5929\u80fd\u4e00\u8fb9\u5236\u51b7\u4e00\u8fb9\u70e7\u70ed\u6c34\u5417\uff1f<\/summary><p>AQ \u4e0d\u884c\u3002\u5b83\u7684\u70ed\u6c34\u548c\u5730\u6696\u662f\u4e8c\u9009\u4e00\uff0c\u540c\u4e00\u65f6\u95f4\u53ea\u8d70\u4e00\u4e2a\u529f\u80fd\uff0c\u5236\u51b7\u65f6\u4e0d\u505a\u70ed\u6c34\u3002\u80fd\u4e00\u8fb9\u5236\u51b7\u3001\u4e00\u8fb9\u628a\u5e9f\u70ed\u56de\u6536\u6765\u70e7\u70ed\u6c34\u7684\uff0c\u662f\u5c0a\u777f\u5168\u6548\u2161 \u914d\u70ed\u6c34\u7bb1\u7684\u4e09\u8054\u4f9b\uff0c\u770b<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u5168\u6548\u2161 \u4ea7\u54c1\u8be6\u60c5<\/a>\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u5730\u6696\u53ef\u4ee5\u5f00\u4e00\u534a\u623f\u95f4\u5417\uff1f<\/summary><p>\u53ef\u4ee5\u3002\u901a\u8fc7\u5206\u96c6\u6c34\u5668\u9600\u95e8\u63a7\u5236\u5404\u56de\u8def\u5f00\u5173\u3002\u4f46\u6ce8\u610f\u8fde\u63a5\u7387\u4e0d\u8981\u4f4e\u4e8e50%\uff0c\u5426\u5219\u5916\u673a\u53ef\u80fd\u9891\u7e41\u542f\u505c\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u5236\u51b7\u548c\u5730\u6696\u80fd\u540c\u65f6\u5f00\u5417\uff1f<\/summary><p>\u4e0d\u80fd\u3002\u540c\u4e00\u65f6\u95f4\u53ea\u80fd\u8fd0\u884c\u4e00\u79cd\u6a21\u5f0f\uff08\u5236\u51b7\u6216\u5236\u70ed\/\u5730\u6696\uff09\u3002\u4f46\u53ef\u4ee5\u4e0d\u540c\u623f\u95f4\u8bbe\u4e0d\u540c\u6e29\u5ea6\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u591a\u4e45\u9700\u8981\u4fdd\u517b\u4e00\u6b21\uff1f<\/summary><p>\u6ee4\u7f51\u6bcf\u6708\u6e05\u6d17\uff0c\u5730\u6696\u5b63\u524d\u4e13\u4e1a\u6392\u6c14+\u8bd5\u8fd0\u884c\uff0c\u6bcf\u5e74\u4e00\u6b21\u4e13\u4e1a\u4fdd\u517b\uff08\u51b7\u5a92\u68c0\u67e5+\u7535\u6c14\u68c0\u67e5\uff09\u3002<\/p><\/details>\n\n<h3 class=\"wp-block-heading\">\u6280\u672f\u7c7b<\/h3>\n\n<details class=\"faq\"><summary>-20\u2103\u771f\u7684\u80fd\u8fd0\u884c\u5417\uff1f<\/summary><p>\u53ef\u4ee5\u3002\u8865\u6c14\u589e\u7113\u538b\u7f29\u673a\u4fdd\u8bc1-20\u2103\u7a33\u5b9a\u5236\u70ed\u3002-25\u2103\u4ecd\u53ef\u542f\u52a8\uff0c\u4f46\u5236\u70ed\u6548\u7387\u4f1a\u4e0b\u964d\uff08COP\u7ea61.5-1.8\uff09\u3002\u6210\u90fd\u51ac\u5b63\u6781\u5c11\u4f4e\u4e8e-5\u2103\uff0c\u5b8c\u5168\u65e0\u538b\u529b\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u4e00\u4f53\u673a\u574f\u4e86\u8981\u6574\u673a\u6362\u5417\uff1f<\/summary><p>\u4e0d\u9700\u8981\u3002\u6c34\u529b\u6a21\u5757\u3001\u538b\u7f29\u673a\u3001\u6362\u70ed\u5668\u3001\u7535\u63a7\u677f\u5747\u4e3a\u72ec\u7acb\u53ef\u66f4\u6362\u7ec4\u4ef6\u3002\u8be6\u89c13.4\u8282\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u8fde\u63a5\u7387\u662f\u4ec0\u4e48\u610f\u601d\uff1f<\/summary><p>\u5ba4\u5185\u673a\u603b\u51b7\u91cf\u9664\u4ee5\u5ba4\u5916\u673a\u989d\u5b9a\u5236\u51b7\u91cf\u3002AQ \u4e0a\u9650 130%\uff0cNQ \u4e0a\u9650 150%\uff0c\u4e24\u6761\u4e0d\u80fd\u6df7\u7528\u3002\u4f4e\u4e8e 50% \u5916\u673a\u9891\u7e41\u542f\u505c\u4f24\u538b\u7f29\u673a\uff0c\u8d85\u8fc7\u5404\u81ea\u7684\u4e0a\u9650\u5c31\u662f\u957f\u671f\u8fc7\u8f7d\u3002NQ \u6309 150% \u914d\u7684\u524d\u63d0\u662f\u540c\u5f00\u7387\uff1a\u7a7a\u8c03\u548c\u5730\u6696\u540c\u65f6\u8dd1\u7684\u8d1f\u8377\u5408\u8ba1\u4e0d\u8d85\u8fc7\u5916\u673a\u7684 66%\uff0c\u8d85\u914d\u5c31\u80fd\u88ab\u5403\u4e0b\u6765\uff0c\u5916\u673a\u4e0d\u7528\u9009\u5927\u4e00\u53f7\u3002<\/p><\/details>\n<details class=\"faq\"><summary>\u5730\u6696\u7ba1\u7528\u4ec0\u4e48\u6750\u8d28\uff1f<\/summary><p>PERT\u6216PEX\u7ba1\uff0c\u4e24\u8005\u5747\u53ef\u3002PERT\u67d4\u97e7\u6027\u66f4\u597d\u9002\u5408\u8584\u5730\u6696\uff0cPEX\u8010\u9ad8\u6e29\u6027\u66f4\u597d\u9002\u5408\u5e38\u89c4\u5730\u6696\u3002<\/p><\/details>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"rlzx13\" class=\"wp-block-heading\">\u7b2c\u5341\u4e09\u7ae0\uff1a\u8fd9\u4efd\u8d44\u6599\u4ec0\u4e48\u65f6\u5019\u66f4\u65b0\u7684<\/h2>\n\n<p>\u8fd9\u4e00\u9875\u7684\u578b\u53f7\u3001\u6863\u4f4d\u3001\u53c2\u6570\uff0c\u8ddf\u7740\u65e5\u7acb\u5b98\u65b9\u6837\u518c\u8d70\u3002\u6837\u518c\u6539\u4e86\u578b\u53f7\u6216\u8005\u52a0\u4e86\u6863\u4f4d\uff0c\u8fd9\u4e00\u9875\u8ddf\u7740\u6539\uff1b\u6539\u4e86\u5c31\u5728\u8fd9\u91cc\u8bb0\u4e00\u884c\uff0c\u65b9\u4fbf\u4f60\u5224\u65ad\u770b\u5230\u7684\u662f\u4e0d\u662f\u6700\u65b0\u7684\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u4ec0\u4e48\u65f6\u5019<\/th><th>\u6539\u4e86\u4ec0\u4e48<\/th><\/tr><\/thead><tbody><tr><td>2026 \u5e74 5 \u6708<\/td><td>\u5efa\u8fd9\u4e00\u9875\u3002\u6280\u672f\u539f\u7406\u3001AQ \u548c NQ \u4e24\u5f20\u53c2\u6570\u8868\u3001\u5b89\u88c5\u89c4\u8303\u3001\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u3001\u6545\u969c\u6392\u67e5\uff0c\u4e00\u6b21\u5199\u5b8c<\/td><\/tr><tr><td>2026 \u5e74 10 \u6708<\/td><td>\u8fd9\u4e00\u9875\u6536\u56de\u5230\u300c\u53ea\u8bb2\u667a\u4eab\u8fd9\u4e00\u53f0\u673a\u5668\u300d\u3002\u5168\u6548\u2161 \u548c\u5c0a\u777f\u522b\u5885\u90a3\u4e24\u6761\u914d\u6cd5\uff0c\u642c\u5230\u300a\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d\u300b\u90a3\u4e00\u9875\u5355\u72ec\u8bb2<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 id=\"rlzxfla\" class=\"wp-block-heading\">\u9644\u5f55A\uff1a\u672f\u8bed\u901f\u67e5\u8868<\/h2>\n\n\n\n<details>\n<summary><strong>\u672f\u8bed\u901f\u67e5\u8868<\/strong><\/summary>\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u672f\u8bed<\/th><th>\u5168\u79f0\/\u91ca\u4e49<\/th><\/tr><\/thead><tbody><tr><td>\u5929\u6c1f\u5730\u6c34<\/td><td>\u6c1f\u7cfb\u7edf\u5236\u51b7+\u6c34\u7cfb\u7edf\u91c7\u6696\u7684\u4e24\u8054\u4f9b\u6280\u672f\u8def\u7ebf<\/td><\/tr><tr><td>\u5929\u6c34\u5730\u6c34<\/td><td>\u5168\u6c34\u7cfb\u7edf\uff08\u6c34\u7cfb\u7edf\u5236\u51b7+\u6c34\u7cfb\u7edf\u91c7\u6696\uff09\u7684\u4e24\u8054\u4f9b\u6280\u672f\u8def\u7ebf<\/td><\/tr><tr><td>AQ<\/td><td>\u667a\u4eab\u4e00\u4f53\u5f0f\uff0c\u6c34\u6a21\u5757\u5185\u7f6e\u5916\u673a\uff0c\u80fd\u51fa\u751f\u6d3b\u70ed\u6c34\u4f46\u4e0e\u5730\u6696\u4e8c\u9009\u4e00<\/td><\/tr><tr><td>NQ<\/td><td>\u667a\u4eab\u4e00\u4f53\u5f0f\uff0c\u6c34\u6a21\u5757\u5185\u7f6e\u5916\u673a\uff0c\u4e0d\u5e26\u751f\u6d3b\u70ed\u6c34\uff0c\u6c34\u6cf5\u548c\u6c34\u6e29\u81ea\u52a8<\/td><\/tr><tr><td>\u4e09\u8054\u4f9b<\/td><td>\u7a7a\u8c03\u3001\u5730\u6696\u3001\u751f\u6d3b\u70ed\u6c34\u4e00\u5957\u7cfb\u7edf\u51fa\uff1b\u5929\u6c1f\u5730\u6c34\u91cc\u53ea\u6709\u5c0a\u777f\u5168\u6548\u2161 \u52a0\u70ed\u6c34\u7bb1\u80fd\u505a\u5230<\/td><\/tr><tr><td>COP<\/td><td>\u80fd\u6548\u6bd4\uff0c\u5236\u70ed\u91cf\/\u8017\u7535\u91cf\uff0c\u8d8a\u9ad8\u8d8a\u8282\u80fd<\/td><\/tr><tr><td>IPLV<\/td><td>\u7efc\u5408\u90e8\u5206\u8d1f\u8377\u6027\u80fd\u7cfb\u6570\uff0c\u53cd\u6620\u90e8\u5206\u8d1f\u8377\u80fd\u6548<\/td><\/tr><tr><td>APF<\/td><td>\u5168\u5e74\u80fd\u6e90\u6d88\u8017\u6548\u7387\uff0c\u7efc\u5408\u5236\u51b7+\u5236\u70ed\u80fd\u6548<\/td><\/tr><tr><td>\u4e24\u8054\u4f9b<\/td><td>\u4e00\u5957\u7cfb\u7edf\u540c\u65f6\u63d0\u4f9b\u5236\u51b7\u548c\u91c7\u6696<\/td><\/tr><tr><td>\u4e09\u8054\u4f9b<\/td><td>\u4e00\u5957\u7cfb\u7edf\u540c\u65f6\u63d0\u4f9b\u5236\u51b7\u3001\u91c7\u6696\u548c\u751f\u6d3b\u70ed\u6c34<\/td><\/tr><tr><td>\u8865\u6c14\u589e\u7113<\/td><td>\u538b\u7f29\u673a\u4e2d\u95f4\u8865\u6c14\u6280\u672f\uff0c\u63d0\u5347\u4f4e\u6e29\u5236\u70ed\u6027\u80fd<\/td><\/tr><tr><td>\u6c1f\u6c34\u6362\u70ed\u5668<\/td><td>\u5c06\u6c1f\u5229\u6602\u70ed\u91cf\u4f20\u9012\u7ed9\u6c34\u7684\u6838\u5fc3\u6362\u70ed\u7ec4\u4ef6<\/td><\/tr><tr><td>\u4e94\u6052\u7cfb\u7edf<\/td><td>\u6052\u6e29\u3001\u6052\u6e7f\u3001\u6052\u6c27\u3001\u6052\u6d01\u3001\u6052\u9759\u7684\u5168\u5c4b\u73af\u5883\u7cfb\u7edf<\/td><\/tr><tr><td>SET-FREE<\/td><td>\u65e5\u7acb\u667a\u4eab\u7684\u8bbe\u8ba1\u7406\u5ff5\uff1a\u5b89\u88c5\u81ea\u7531\u3001\u8bbe\u8ba1\u81ea\u7531\u3001\u7a7a\u95f4\u81ea\u7531<\/td><\/tr><tr><td>\u5168\u5c4b\u5168\u611f<\/td><td>\u65e5\u7acb\u4e94\u6052\u7cfb\u7edf\u54c1\u724c\uff0c\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e3a\u57fa\u5ea7<\/td><\/tr><tr><td>\u6c34\u6a21\u5757<\/td><td>\u8fde\u63a5\u5929\u6c1f\u5730\u6c34\u5916\u673a\u4e0e\u5730\u6696\u7ba1\u7f51\u7684\u6838\u5fc3\u8bbe\u5907\uff0c\u5b9e\u73b0\u6c1f\u2192\u6c34\u6362\u70ed<\/td><\/tr><tr><td>RWMG<\/td><td>\u65e5\u7acb\u6c34\u6a21\u5757\u578b\u53f7\u524d\u7f00\uff0c\u5982RWMG-160FWXNZQ<\/td><\/tr><tr><td>\u8fde\u63a5\u7387<\/td><td>\u5ba4\u5185\u673a\u603b\u51b7\u91cf\u00f7\u5ba4\u5916\u673a\u989d\u5b9a\u5236\u51b7\u91cf\uff0c\u5efa\u8bae90%-130%<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/details>\n\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u60f3\u4e86\u89e3\u9f99\u8109\u6696\u901a\u5176\u4ed6\u51b7\u6696\u8212\u9002\u65b9\u6848\uff1f<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1946\">\u65e5\u7acbVAM mini II \u5c0a\u777fmini\u4e8c\u4ee3\u8be6\u60c5\u9875<\/a>\u3011\u2192 \u9ad8\u6548\u8282\u80fd+\u6807\u914d\u51c0\u5316\uff0c\u65e0\u5730\u6696\u9700\u6c42\u9996\u9009<\/li>\n\n\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161 \u8be6\u60c5\u9875<\/a>\u3011\u2192 \u6e29\u6e7f\u53cc\u63a7\u65d7\u8230\uff0c\u6781\u81f4\u8212\u9002<\/li>\n\n\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1233\">\u65e5\u7acb\u6c34\u5885\u9002 \u8be6\u60c5\u9875<\/a>\u3011\u2192 \u5929\u6c34\u5730\u6c34\uff0c\u5927\u6237\u578b\/\u522b\u5885\u6781\u81f4\u8212\u9002<\/li>\n\n\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1824\">\u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5\u9875<\/a>\u3011\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=835\">\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5\u9875<\/a>\u3011\u2192 \u5fb7\u56fd\u51b7\u51dd\u7089\u6280\u672f\uff0c\u72ec\u7acb\u5730\u6696\u6696\u6c14\u7247\u65b9\u6848<\/li>\n\n\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1841\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5\u9875<\/a>\u3011\u2192 \u56fd\u4ea7\u6280\u672f\uff0c\u6ce8\u91cd\u63a7\u5236\u8d28\u91cf\uff0c\u4e3b\u6253\u6027\u4ef7\u6bd4\uff0c\u4e0e\u9f99\u8109\u6696\u901a\u5408\u4f5c\u5f00\u53d1\u53d8\u9891\u5c0f\u529f\u7387\u5355\u91c7\u6696\u65b9\u6848\uff0c\u8282\u80fd\u7701\u94b1<\/li>\n\n\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1849\">\u5168\u5c4b\u51c0\u6c34\u7cfb\u7edf\u77e5\u8bc6\u805a\u5408\u9875<\/a>\u3011\u2192 \u4e94\u4ef6\u5957\u9009\u8d2d\u6307\u5357<\/li>\n\n\n\n\n<\/ul>\n<\/blockquote>\n\n\n\n<div style=\"margin:26px 0;padding:16px 18px;background:#f6f8fa;border-left:4px solid #1a2b3c;border-radius:8px;\" data-page-node-id=\"jgwzhbAV6K4t5OBY3a37Nq\">\n  <div style=\"font-size:15px;font-weight:700;color:#1a2b3c;margin-bottom:6px;\" data-page-node-id=\"CDhXQmPyEyboIIKdR2HRII\">\u8fd9\u53f0\u673a\u5668\u9002\u5408\u4f60\u5bb6\u5417\uff1f\u5148\u770b\u9009\u578b\u903b\u8f91<\/div>\n  <div style=\"font-size:14px;line-height:1.8;color:#3c4d5c;margin-bottom:10px;\" data-page-node-id=\"mlFliZj06IYHFAojusWoRv\">\n    \u5355\u54c1\u53c2\u6570\u53ea\u8bf4\u660e\"\u5b83\u662f\u4ec0\u4e48\"\uff0c\u6237\u578b\u9762\u79ef\u3001\u671d\u5411\u3001\u5c42\u9ad8\u3001\u662f\u5426\u88c5\u5730\u6696\u624d\u51b3\u5b9a\"\u4f60\u8be5\u9009\u54ea\u53f0\"\u3002\u767d\u76ae\u4e66\u91cc\u6709\u5b8c\u6574\u7684\u8d1f\u8377\u7b97\u6cd5\u4e0e\u8d85\u914d\u7387\u533a\u95f4\u3002\n  <\/div>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=12292\" style=\"display:inline-block;padding:9px 15px;background:#1a2b3c;color:#fff;border-radius:6px;text-decoration:none;font-size:14px;font-weight:600;\" data-page-node-id=\"o15L9UmJ3X65ZyE3H29A6I\">\n    \u67e5\u9009\u578b\u65b9\u6cd5\u4e0e\u56fd\u6807\u8d1f\u8377\uff1a\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66\n  <\/a>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u672c\u6587\u6863\u4ee5\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u7684\u53d1\u5c55\u5386\u7a0b\u4e3a\u53d9\u4e8b\u4e3b\u7ebf\uff0c\u4ee5\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u767e\u5e74\u6280\u672f\u79ef\u6dc0\u4e3a\u5bf9\u7167\u526f\u7ebf\uff0c\u6574\u5408\u5b98\u65b9\u8d44\u6599\u3001\u884c\u4e1a\u62a5\u544a\u4e0e\u7528\u6237\u5b9e\u88c5\u6848\u4f8b\uff0c\u5f62\u6210\u4e00\u4efd\u5b8c\u6574\u7684\u4ea7\u54c1\u8be6\u60c5\u3002<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u627e\u9f99\u8109\u6696\u901a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0b\u9762\u8fd9\u4e9b\u662f\u9009\u4e86\u667a\u4eab\u4ee5\u540e\u6700\u5e38\u95ee\u7684\u51e0\u4ef6\u4e8b\uff1a\u591a\u5c11\u94b1\u3001\u600e\u4e48\u88c5\u3001\u574f\u4e86\u8c01\u7ba1\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u627f\u8bfa<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u514d\u8d39\u54a8\u8be2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8054\u7cfb\u6211\u4eec\uff0c\u5373\u53ef\u83b7\u5f971\u5bf91\u65b9\u6848\u8bbe\u8ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e13\u4e1a\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u8c28\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u9009\u578b\uff0c\u63d0\u4f9b1-2\u5957\u4f9b\u6696\u65b9\u6848<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cbe\u5de5\u5b89\u88c5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u683c\u6267\u884c\u7cbe\u5de5\u516d\u6b65\u6cd5\uff0c\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u80fd\u6e90\u4fdd\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u5165\u4f1a\u5458\u8ba1\u5212\uff0c\u9501\u5b9a\u672a\u676510\u5e74\u91c7\u6696\u80fd\u8017\uff0c\u8d85\u51fa\u90e8\u5206\u6211\u4eec\u627f\u62c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u670d\u52a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u7ef4\u62a4\u3001\u6bcf\u5e74\u4e00\u6b21\u514d\u8d39\u4f53\u68c0\u3001\u6545\u969c\u62a5\u4fee2\u5c0f\u65f6\u54cd\u5e94\u300124\u5c0f\u65f6\u5185\u4e0a\u95e8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5382\u5bb6\u8d1f\u8d23\u4ea7\u54c1\uff0c\u9f99\u8109\u8d1f\u8d23\u7ed3\u679c\u3002<\/strong>&nbsp;\u540c\u6837\u7684\u70ed\u6c34\u7cfb\u5217\uff0c\u4e0d\u540c\u5b89\u88c5\u5546\u88c5\u51fa\u6765\u7684\u6548\u679c\u548c\u80fd\u8017\u80fd\u5dee\uff1e30%\u3002\u6211\u4eec\u7684\u5dee\u5f02\u5316\u5728\u4e8e\uff1a\u7cfb\u7edf\u56db\u8981\u7d20\u8bbe\u8ba1\uff08\u70ed\u6e90-\u8f93\u914d-\u672b\u7aef-\u63a7\u5236\u5339\u914d\uff09\u3001\u91c7\u6696\u4e0e\u70ed\u6c34\u5206\u79bb\u8bbe\u8ba1\u3001\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u3001\u4ee5\u53ca\u4f1a\u5458\u5236\u957f\u671f\u670d\u52a1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u642d\u914d<a href=\"https:\/\/longmai-nt.com\/?page_id=1758\">\u65e5\u7acb\u65b0\u98ce<\/a>+<a href=\"https:\/\/longmai-nt.com\/?page_id=916\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/a>\uff0c\u53ef\u5b9e\u73b0\u65e5\u7acb\u5168\u5c4b\u5168\u611f2.0\u4e94\u6052\u7cfb\u7edf\uff0c\u9f99\u8109\u6696\u901a\u4e3a\u4e24\u8054\u4f9b\u7528\u6237\u63d0\u4f9b<a href=\"https:\/\/longmai-nt.com\/?page_id=518\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/a>\uff0c\u6301\u7eed\u6027\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\uff0c\u6253\u9020\u6301\u7eed\u6027\u8282\u80fd\u7a33\u5b9a\u7684\u8212\u9002\u5bb6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde&nbsp;<strong>\u6210\u90fd\u5357\u5bcc\u68ee\u70ed\u7ebf\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><\/strong><br>\ud83d\udcde&nbsp;<strong>\u6210\u90fd\u5317\u5bcc\u68ee\u70ed\u7ebf\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff1a <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892%7C30.598786%7C104.074284%7C30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\"><\/a><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892%7C30.598786%7C104.074284%7C30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\">\ud83d\udccd \u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B\u3001A348<\/a><br>\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u6210\u534e\u5e97\uff1a<a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547%7C30.599807%7C104.07041%7C30.604665&amp;query_type=IDQ&amp;query=%E6%88%90%E9%83%BD%E6%97%A5%E7%AB%8B%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%99%BA%E6%85%A7%E7%A9%BA%E6%B0%94%E9%A6%86(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8C%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17.5\">\ud83d\udccd \u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u987e\u95ee\u76f4\u62e8<\/strong>\uff1a\u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a>\u3000\u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a><br>\n<strong>\u552e\u540e<\/strong>\uff1a\u6768\u6676\u6676 <a href=\"tel:15680075476\">156-8007-5476<\/a>\uff5c\u670d\u52a1\u8303\u56f4\uff1a\u6210\u90fd\u5168\u57df\uff5c\u8425\u4e1a\u65f6\u95f4\uff1a\u5468\u4e00\u81f3\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u81f3\u5468\u65e5 10:00\u201319:00<\/p>\n\n\n\n<section class=\"geo-footer-block\">\n  <h2>\u63a5\u7740\u770b\uff1a\u4ece\u8fd9\u4e00\u53f0\u673a\u5668\u770b\u5230\u6574\u5957\u7cfb\u7edf<\/h2>\n  <div class=\"link-cards\">\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=16752\" target=\"_blank\">\n      <span class=\"title\">\u667a\u4eab\u3001\u5168\u6548\u3001\u522b\u5885\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/span>\n      <span class=\"desc\">\u56db\u6761\u914d\u6cd5\u7684\u578b\u53f7\u3001\u8d85\u914d\u7387 130% \u548c 150% \u600e\u4e48\u7528\u3001\u54ea\u4e9b\u623f\u5b50\u4e0d\u63a8\u8350<\/span>\n    <\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=671\" target=\"_blank\">\n      <span class=\"title\">\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/span>\n      <span class=\"desc\">\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u4e24\u6761\u8def\u7684\u6765\u9f99\u53bb\u8109<\/span>\n    <\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12825\" target=\"_blank\">\n      <span class=\"title\">\u4e24\u8054\u4f9b\u600e\u4e48\u9009\uff1a\u6c34\u673a\u8fd8\u662f\u6c1f\u673a<\/span>\n      <span class=\"desc\">\u7a7a\u8c03\u9762\u79ef\u5927\u3001\u5e38\u4f4f\u4eba\u5c11\u7684\u65f6\u5019\uff0c\u4e3a\u4ec0\u4e48\u8be5\u770b\u6c34\u5885\u9002<\/span>\n    <\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=13098\" target=\"_blank\">\n      <span class=\"title\">\u6c34\u5885\u9002 \u5168\u53d8\u9891\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\u767d\u76ae\u4e66<\/span>\n      <span class=\"desc\">\u5929\u6c34\u5730\u6c34\u8fd9\u6761\u8def\uff1a\u4e3b\u673a\u81ea\u7531\u3001\u4e0d\u53d7\u8fde\u63a5\u7387\u9650\u5236<\/span>\n    <\/a>\n  <\/div>\n\n  <h3>\u540c\u7cfb\u5217\u5355\u54c1\u8be6\u60c5\uff08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\uff09<\/h3>\n  <div class=\"link-cards\">\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\"><span class=\"title\">EX-\u8212\u4eab\uff08SET-FREE\uff09<\/span><span class=\"desc\">\u5165\u95e8\u53cc\u8f6c\u5b50 \u00b7 \u9ad8\u53ef\u9760<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1946\" target=\"_blank\"><span class=\"title\">VAMmini \u2161<\/span><span class=\"desc\">\u5c0f\u6237\u9996\u9009 \u00b7 \u6da1\u65cb\u538b\u7f29\u673a<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1811\" target=\"_blank\"><span class=\"title\">\u5c0a\u777f\u5168\u6548\u2161<\/span><span class=\"desc\">\u4e09\u7ba1\u5236\u6e29\u6e7f\u53cc\u63a7 \u00b7 \u53ef\u52a0\u70ed\u6c34\u7bb1\u505a\u4e09\u8054\u4f9b<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2543\" target=\"_blank\"><span class=\"title\">VAM \u5c0a\u777f\u522b\u5885<\/span><span class=\"desc\">\u5927\u51b7\u91cf \u00b7 \u4e00\u53f0\u5916\u673a\u5e26\u4e24\u4e09\u53f0\u6c34\u6a21\u5757<\/span><\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\"><span class=\"title\">\u6c34\u5885\u9002 VF<\/span><span class=\"desc\">\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b<\/span><\/a>\n  <\/div>\n\n  <h3>\u4ef7\u683c\u4e0e\u552e\u540e<\/h3>\n  <div class=\"link-cards\">\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10970\" target=\"_blank\">\n      <span class=\"title\">\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7efc\u5408\u53c2\u8003\u4ef7\u683c<\/span>\n      <span class=\"desc\">\u8212\u4eab \/ VAMmini\u2161 \/ \u5c0a\u777f\u5168\u6548 \/ \u667a\u4eab \/ \u6c34\u5885\u9002 \u4e00\u62d6\u591a\u9884\u7b97\u5bf9\u6bd4<\/span>\n    <\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=14057\" target=\"_blank\">\n      <span class=\"title\">\u552e\u540e\u4ef7\u76ee\u8868\uff5c\u4e0a\u95e8\u8d39\u4e0e\u68c0\u4fee\u600e\u4e48\u7b97<\/span>\n      <span class=\"desc\">\u5148\u62a5\u4ef7\u540e\u5f00\u5de5\u3001\u539f\u5382\u4ef6\u3001\u540c\u95ee\u9898\u534a\u5e74\u514d\u8d39\u590d\u67e5<\/span>\n    <\/a>\n    <a class=\"link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=11074\" target=\"_blank\">\n      <span class=\"title\">\u58c1\u6302\u7089\u600e\u4e48\u9009\uff5c\u6210\u90fd\u5bb6\u5ead\u907f\u5751\u6307\u5357<\/span>\n      <span class=\"desc\">\u51b7\u51dd \/ \u5e38\u89c4 \u00b7 \u529f\u7387 \u00b7 \u54c1\u724c\u6a2a\u8bc4<\/span>\n    <\/a>\n  <\/div>\n\n<section style=\"margin:36px 0;padding:22px 24px;background:#f5f8fc;border-left:4px solid #E8541E;border-radius:10px;\">\n  <h3 style=\"margin:0 0 12px;color:#12314F;font-size:18px;font-weight:700;\">\u76f8\u5173\u9605\u8bfb \u00b7 \u5341\u5e74\u5305\u4fee\u4e0e\u5f53\u524d\u6d3b\u52a8<\/h3>\n  <ul style=\"margin:0;padding-left:22px;line-height:2.1;color:#1f2d3d;\">\n    <li style=\"margin:0;\"><a href=\"https:\/\/longmai-nt.com\/?page_id=12258\" target=\"_blank\" rel=\"noopener\" style=\"color:#12314F;text-decoration:none;border-bottom:1px solid #E8541E;\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u300c\u5341\u5e74\u5305\u4fee\u300d\u653f\u7b56\u8be6\u89e3\uff1a\u4ea7\u54c1 10 \u5e74 + \u5b89\u88c5 10 \u5e74\uff0c\u5382\u5bb6\u5148\u670d\u52a1\u540e\u8ffd\u8d23<\/a><\/li>\n    <li style=\"margin:0;\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1369\" target=\"_blank\" rel=\"noopener\" style=\"color:#12314F;text-decoration:none;border-bottom:1px solid #E8541E;\">\u65e5\u7acb\u91d1\u79cb\u53cc\u8282 \u00b7 \u9f99\u8109\u4f1a\u5458\u8054\u5408\u5b63\uff1a\u5382\u8865\u6700\u9ad8\u62b5 2000 \u5143\uff0c\u7b7e\u7ea6\u5373\u4eab 10 \u5e74\u5305\u4fee<\/a><\/li>\n  <\/ul>\n<\/section>\n\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u5148\u7ed9\u7ed3\u8bba\uff1a\u8fd9\u4e00\u9875\u53ea\u8bb2\u667a\u4eab\u8fd9\u4e00\u53f0\u673a\u5668 \u65e5\u7acb [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":671,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1957","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0cAQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u3002AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u4e0d\u51fa\u70ed\u6c34\uff0c\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\uff0c\u8d85\u914d\u7387\u80fd\u5230 150%\u3002\u4e24\u4e2a\u7cfb\u5217\u7684\u5916\u673a\u578b\u53f7\u3001\u53c2\u6570\u8868\u3001\u5185\u673a\u600e\u4e48\u914d\u3001\u65bd\u5de5\u9a8c\u6536\u548c\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u90fd\u5728\u8fd9\u9875\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1957\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0cAQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u3002AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u4e0d\u51fa\u70ed\u6c34\uff0c\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\uff0c\u8d85\u914d\u7387\u80fd\u5230 150%\u3002\u4e24\u4e2a\u7cfb\u5217\u7684\u5916\u673a\u578b\u53f7\u3001\u53c2\u6570\u8868\u3001\u5185\u673a\u600e\u4e48\u914d\u3001\u65bd\u5de5\u9a8c\u6536\u548c\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u90fd\u5728\u8fd9\u9875\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1957\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-28T10:03:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"ItemPage\"],\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957\",\"name\":\"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-zxskxllgxtylt.jpg\",\"datePublished\":\"2026-05-31T11:58:40+00:00\",\"dateModified\":\"2026-10-28T10:03:26+00:00\",\"description\":\"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0cAQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u3002AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u4e0d\u51fa\u70ed\u6c34\uff0c\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\uff0c\u8d85\u914d\u7387\u80fd\u5230 150%\u3002\u4e24\u4e2a\u7cfb\u5217\u7684\u5916\u673a\u578b\u53f7\u3001\u53c2\u6570\u8868\u3001\u5185\u673a\u600e\u4e48\u914d\u3001\u65bd\u5de5\u9a8c\u6536\u548c\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u90fd\u5728\u8fd9\u9875\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-zxskxllgxtylt.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/tysjt-zxskxllgxtylt.jpg\",\"width\":1754,\"height\":1240},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1957#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5 - \u9f99\u8109\u6696\u901a","description":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0cAQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u3002AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u4e0d\u51fa\u70ed\u6c34\uff0c\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\uff0c\u8d85\u914d\u7387\u80fd\u5230 150%\u3002\u4e24\u4e2a\u7cfb\u5217\u7684\u5916\u673a\u578b\u53f7\u3001\u53c2\u6570\u8868\u3001\u5185\u673a\u600e\u4e48\u914d\u3001\u65bd\u5de5\u9a8c\u6536\u548c\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u90fd\u5728\u8fd9\u9875\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1957","og_locale":"zh_CN","og_type":"article","og_title":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5 - \u9f99\u8109\u6696\u901a","og_description":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0cAQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u3002AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u4e0d\u51fa\u70ed\u6c34\uff0c\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\uff0c\u8d85\u914d\u7387\u80fd\u5230 150%\u3002\u4e24\u4e2a\u7cfb\u5217\u7684\u5916\u673a\u578b\u53f7\u3001\u53c2\u6570\u8868\u3001\u5185\u673a\u600e\u4e48\u914d\u3001\u65bd\u5de5\u9a8c\u6536\u548c\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u90fd\u5728\u8fd9\u9875\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=1957","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-28T10:03:26+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"13 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","ItemPage"],"@id":"https:\/\/longmai-nt.com\/?page_id=1957","url":"https:\/\/longmai-nt.com\/?page_id=1957","name":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=1957#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=1957#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg","datePublished":"2026-05-31T11:58:40+00:00","dateModified":"2026-10-28T10:03:26+00:00","description":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0cAQ \u548c NQ \u90fd\u662f\u4e00\u4f53\u673a\uff0c\u6c34\u6a21\u5757\u88c5\u5728\u5ba4\u5916\u673a\u91cc\u3002AQ \u80fd\u51fa\u70ed\u6c34\u4f46\u548c\u5730\u6696\u4e8c\u9009\u4e00\u3001\u6c34\u6e29\u624b\u52a8\u8c03\uff1bNQ \u4e0d\u51fa\u70ed\u6c34\uff0c\u6807\u914d\u81ea\u9002\u5e94\u53d8\u9891\u6c34\u6cf5\u3001\u81ea\u52a8\u53d8\u6c34\u6e29\uff0c\u8d85\u914d\u7387\u80fd\u5230 150%\u3002\u4e24\u4e2a\u7cfb\u5217\u7684\u5916\u673a\u578b\u53f7\u3001\u53c2\u6570\u8868\u3001\u5185\u673a\u600e\u4e48\u914d\u3001\u65bd\u5de5\u9a8c\u6536\u548c\u6210\u90fd\u5b9e\u88c5\u6848\u4f8b\u90fd\u5728\u8fd9\u9875\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1957#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1957"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=1957#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-zxskxllgxtylt.jpg","width":1754,"height":1240},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1957#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c","item":"https:\/\/longmai-nt.com\/?page_id=671"},{"@type":"ListItem","position":3,"name":"\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 AQ \u548c NQ \u600e\u4e48\u9009\u3001\u600e\u4e48\u88c5"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1957","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1957"}],"version-history":[{"count":45,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1957\/revisions"}],"predecessor-version":[{"id":16772,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1957\/revisions\/16772"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/671"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1957"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}