{"id":1976,"date":"2026-06-02T02:22:46","date_gmt":"2026-06-01T18:22:46","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1976"},"modified":"2026-10-26T23:37:36","modified_gmt":"2026-10-26T15:37:36","slug":"%e5%9c%b0%e6%9a%96%e7%b3%bb%e7%bb%9f-%c2%b7-%e8%81%9a%e5%90%88%e9%a1%b5%e7%9f%a5%e8%af%86%e5%ba%95%e5%ba%a7","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1976","title":{"rendered":"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7"},"content":{"rendered":"\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a \u00b7 \u672c\u6587\u6863\u4e3a\u5730\u6696\u805a\u5408\u9875\u7684\u5b8c\u6574\u5185\u5bb9\u7d20\u6750\u5e93\u3002\u6210\u90fd\u5730\u6696\u600e\u4e48\u9009\u624d\u4e0d\u8e29\u5751\uff1f\u672c\u9875\u4ece\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u4e2a\u73af\u8282\u8bb2\u6e05\u5730\u6696\u7cfb\u7edf\u7684\u5e95\u5c42\u903b\u8f91\uff0c \u542b\u58c1\u6302\u7089\u4e0e\u7a7a\u6c14\u80fd\u5bf9\u6bd4\u300120 \u5e74\u6210\u672c\u6d4b\u7b97\u3001\u6210\u90fd\u672c\u5730\u5b8c\u5de5\u6848\u4f8b\u4e0e\u9a8c\u6536\u7ea2\u7ebf\u3002 \u5168\u6587\u57fa\u4e8e\u9f99\u8109\u6696\u901a \u81ea2004\u5e74\u8d77\u6210\u90fd\u672c\u5730\u8bbe\u8ba1\u3001\u65bd\u5de5\u7ecf\u9a8c\u4e0e\u56fd\u5bb6\u6807\u51c6\u6574\u7406\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8bbe\u8ba1\u7406\u5ff5\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a\u77e5\u8bc6\u5e93 + \u56fd\u5bb6\u8bbe\u8ba1\u89c4\u8303<\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading has-icon has-icon-right\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u76ee\u5f55 <\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n<div aria-labelledby=\"accordion-item-1\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<h2 class=\"wp-block-heading\"><strong>\u5730\u6696\u805a\u5408\u9875\uff08\u4e0a\u4e0b\u518c\uff09 \u00b7 \u5b8c\u6574\u6807\u9898\u4e0e\u76ee\u5f55<\/strong><\/h2>\n\n<h3 class=\"wp-block-heading\"><strong>\u4e0a\u518c\uff1a\u4ece\u539f\u59cb\u9700\u6c42\u5230\u7cfb\u7edf\u8ba4\u77e5<\/strong><\/h3>\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#dnxt01\">\u7b2c\u4e00\u7ae0\uff1a\u4f60\u4e5f\u7ecf\u5386\u8fc7\u2026\u2026\uff08\u4ece\u539f\u59cb\u53d6\u6696\u5230\u73b0\u4ee3\u5730\u6696\uff09<\/a><\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#dnxt0101\"><strong>1.1<\/strong> \u4e24\u6761\u4e3b\u7ebf\u7684\u5e76\u884c\u6f14\u8fdb<\/a>\n<ul class=\"wp-block-list\">\n<li><em>\u4e3b\u7ebf\u4e00<\/em>\uff1a\u91c7\u6696\u65b9\u5f0f\u7684\u6f14\u8fdb\uff08\u70e4\u706b \u2192 \u73b0\u4ee3\u5730\u6696 \u2192 \u591a\u80fd\u4e92\u8865\uff09<\/li>\n\n<li><em>\u4e3b\u7ebf\u4e8c<\/em>\uff1a\u9700\u6c42\u4e0e\u75db\u70b9\u7684\u5347\u7ea7\uff08\u751f\u5b58 \u2192 \u8212\u9002 \u2192 \u7ecf\u6d4e \u2192 \u4f4e\u78b3\uff09<\/li>\n<\/ul>\n<\/li>\n\n<li><a href=\"#dnxt0102\"><strong>1.2<\/strong> \u539f\u59cb\u9636\u6bb5\u7684\u5c40\u9650\uff1a\u70e4\u706b\u53d6\u6696<\/a><\/li>\n\n<li><a href=\"#dnxt0103\"><strong>1.3<\/strong> \u73b0\u4ee3\u9636\u6bb5\u7684\u5d1b\u8d77\uff1a\u5730\u6696\u7cfb\u7edf<\/a><\/li>\n\n<li><a href=\"#dnxt0104\"><strong>1.4<\/strong> \u591a\u80fd\u4e92\u8865\u65f6\u4ee3\u7684\u7cfb\u7edf\u5316<\/a><\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#dnxt02\">\u7b2c\u4e8c\u7ae0\uff1a\u62c5\u5fc3\u75db\u70b9\u4e0e\u8bef\u533a\uff08\u8ba4\u77e5\u5148\u884c\uff09<\/a><\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#dnxt0202\"><strong>2.1<\/strong> \u7528\u6237\u4e94\u5927\u6838\u5fc3\u8bc9\u6c42\uff08\u8212\u9002\u3001\u7a33\u5b9a\u3001\u8282\u80fd\u3001\u5065\u5eb7\u3001\u4fbf\u6377\uff09<\/a><\/li>\n\n<li><a href=\"#dnxt0203\"><strong>2.2<\/strong> \u516d\u5927\u5e38\u89c1\u8bef\u533a\u4e0e\u771f\u76f8<\/a>\n<ul class=\"wp-block-list\">\n<li>\u8bef\u533a\u4e00\uff1a\u201c\u9505\u7089\u529f\u7387\u8d8a\u5927\u8d8a\u597d\u201d<\/li>\n\n<li>\u8bef\u533a\u4e8c\uff1a\u201c\u51b7\u51dd\u7089\u4e70\u56de\u6765\u5c31\u8282\u80fd\u201d<\/li>\n\n<li>\u8bef\u533a\u4e09\uff1a\u201c\u591a\u5f00\u6696\u6c14\u7247\u66f4\u8282\u80fd\u201d<\/li>\n\n<li>\u8bef\u533a\u56db\uff1a\u201c\u5730\u6696\u7ba1\u5b50\u94fa\u5f97\u8d8a\u5bc6\u8d8a\u70ed\u201d<\/li>\n\n<li>\u8bef\u533a\u4e94\uff1a\u201c\u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u662f\u6b63\u5e38\u7684\u201d<\/li>\n\n<li>\u8bef\u533a\u516d\uff1a\u201c\u96f6\u51b7\u6c34\u662f\u6700\u597d\u7684\u70ed\u6c34\u65b9\u6848\u201d<\/li>\n<\/ul>\n<\/li>\n\n<li><a href=\"#dnxt0203\"><strong>2.3<\/strong> \u5e38\u89c1\u9519\u8bef\u89e3\u51b3\u624b\u6bb5\u4e0e\u98ce\u9669<\/a><\/li>\n\n<li><a href=\"#dnxt0204\"><strong>2.4<\/strong> \u7528\u6237\u5e38\u89c1\u62c5\u5fc3\u4e0e\u6b63\u786e\u5e94\u5bf9\u7b56\u7565<\/a>\n<ul class=\"wp-block-list\">\n<li><strong>\u3010\u8865\u5145\u5185\u5bb9\u3011 20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\u6848\u4f8b<\/strong>\uff08\u666e\u901a\u7089 vs \u51b7\u51dd\u7089 vs \u7a7a\u6c14\u80fd\uff09<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e09\u7ae0\uff1a\u70ed\u6e90\u2014\u2014\u7cfb\u7edf\u7684\u201c\u5fc3\u810f\u201d<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>3.1<\/strong> \u9505\u7089\u5de5\u4f5c\u539f\u7406\u4e0e\u75db\u70b9\u5185\u94fe\n<ul class=\"wp-block-list\">\n<li><em>\u5185\u94fe\uff08\u5feb\u901f\u5b9a\u4f4d\u81f3\u7b2c\u4e8c\u7ae0\u5bf9\u5e94\u7ae0\u8282\uff09<\/em>\uff1a\u5de5\u4f5c\u539f\u7406 \u2192 \u9891\u7e41\u542f\u505c \u2192 \u65e0\u6548\u4ea7\u70ed \u2192 \u80fd\u8017\u98d9\u5347<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>3.2<\/strong> \u4e24\u7528\u58c1\u6302\u7089\u7684\u6839\u672c\u77db\u76fe\n<ul class=\"wp-block-list\">\n<li>3.2.0 \u7cfb\u7edf\u5316\u601d\u7ef4\uff1a\u70ed\u6e90\u9009\u578b\u7684\u94c1\u4e09\u89d2<\/li>\n\n<li>3.2.1 \u7ec8\u6781\u65b9\u6848\uff1a\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u6848\u4f8b<\/li>\n\n<li>3.2.3 \u5e38\u89c4\u7089\u7684\u4f18\u5316\u8def\u5f84<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>3.3<\/strong> \u5e38\u89c4\u7089 vs \u51b7\u51dd\u7089<\/li>\n\n<li><strong>3.4<\/strong> \u7a7a\u6c14\u80fd\u70ed\u6cf5\u7cfb\u7edf<\/li>\n\n<li><strong>3.5<\/strong> \u7535\u80fd\u91c7\u6696\u7cfb\u7edf\uff08\u53d1\u70ed\u7535\u7f06 vs \u7535\u70ed\u819c\uff09<\/li>\n\n<li><strong>3.6<\/strong> \u70ed\u6e90\u9009\u578b\u4e09\u539f\u5219\u4e0e\u62a5\u8b66\u6761\u4ef6<\/li>\n\n<li><strong>3.7<\/strong> \u4e09\u5927\u70ed\u6e90\u9635\u8425\u5168\u666f\u5bf9\u6bd4<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u56db\u7ae0\uff1a\u8f93\u914d\u3001\u672b\u7aef\u4e0e\u63a7\u5236\u2014\u2014\u4ece\u201c\u4ea7\u70ed\u201d\u5230\u201c\u7528\u70ed\u201d\u7684\u5b8c\u6574\u94fe\u8def<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>4.1 \u8f93\u914d\u7cfb\u7edf<\/strong>\n<ul class=\"wp-block-list\">\n<li><a href=\"#dnxt040101\">4.1.1 \u7ba1\u9053\u6750\u6599\u77e9\u9635\uff08PE-RT\u3001PE-X\u3001\u94dd\u5851\u7ba1\u3001PPR\uff09<\/a><\/li>\n\n<li>4.1.2 \u7ba1\u5f84\u9009\u62e9\uff08De16 vs De20\uff1b\u4e3b\u7ba1\u5347\u7ea7\uff09<\/li>\n\n<li>4.1.3 \u6c34\u529b\u5e73\u8861\uff08\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f vs \u5f02\u7a0b\uff09<\/li>\n\n<li>4.1.4 \u8f85\u6750\u6df1\u5ea6\u89e3\u6790\uff08\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u8fb9\u89d2\u6761\uff09\n<ul class=\"wp-block-list\">\n<li><strong>\u3010\u77e5\u8bc6\u5e93\u6570\u636e\u5f15\u7528\u3011 \u7eff\u7fbd\u4e0e\u4f1f\u661f\u767d\u6676\u677f\u68c0\u6d4b\u62a5\u544a\u5bf9\u6bd4<\/strong><\/li>\n<\/ul>\n<\/li>\n\n<li>4.1.5 \u6838\u5fc3\u914d\u4ef6\u4e0e\u6c34\u8d28\u8981\u6c42\n<ul class=\"wp-block-list\">\n<li><strong>\u3010\u8865\u5145\u5185\u5bb9\u3011 \u6c34\u8d28\u5bf9\u7cfb\u7edf\u5bff\u547d\u7684\u5f71\u54cd<\/strong><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>4.2 \u672b\u7aef\u7cfb\u7edf<\/strong>\n<ul class=\"wp-block-list\">\n<li>4.2.1 \u5730\u6696\u76d8\u7ba1\u4e0e\u6563\u70ed\u5f62\u5f0f<\/li>\n\n<li>4.2.2 \u56de\u586b\u5c42\u6df1\u5ea6\u89e3\u6790\uff08\u6e7f\u6cd5 vs \u5e72\u6cd5\uff09<\/li>\n\n<li>4.2.3 \u4e8c\u6b21\u7cfb\u7edf\u5224\u65ad\uff08\u58c1\u6302\u7089 vs \u7a7a\u6c14\u80fd\uff0c\u542b\u914d\u7f6e\u65b9\u6848\uff09<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>4.3 \u63a7\u5236\u7cfb\u7edf\uff08\u201c\u5927\u8111\u4e0e\u795e\u7ecf\u201d\uff09<\/strong>\n<ul class=\"wp-block-list\">\n<li>4.3.1 \u6838\u5fc3\u77db\u76fe\uff1a\u6c34\u6e29\u63a7\u5236 vs \u5ba4\u6e29\u63a7\u5236<\/li>\n\n<li>4.3.2 \u63a7\u5236\u7c7b\u578b\u6f14\u8fdb\u4e0e\u5bf9\u6bd4<\/li>\n\n<li>4.3.3 \u6838\u5fc3\u90e8\u4ef6\u4e0e\u6b63\u786e\u8054\u52a8\u903b\u8f91<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>4.4 \u201c\u56db\u8981\u7d20\u201d\u5339\u914d\u7684\u9ec4\u91d1\u6cd5\u5219<\/strong><\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\"><strong>\u4e0b\u518c\uff1a\u4ece\u65b9\u6848\u843d\u5730\u5230\u7cfb\u7edf\u7ef4\u62a4<\/strong><\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u4e94\u7ae0\uff1a\u54c1\u724c\u9635\u8425\u4e0e\u9009\u578b\u51b3\u7b56<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>5.1<\/strong> \u6838\u5fc3\u54c1\u724c\u4ecb\u7ecd\uff08\u5ba2\u89c2\u9648\u8ff0\uff09<\/li>\n\n<li><strong>5.2<\/strong> <strong>\u5347\u7ea7\u9879\uff1a[\u9009\u578b\u51b3\u7b56\u6811]\u4f5c\u4e3a\u72ec\u7acb\u7ae0\u8282\/\u6838\u5fc3\u5bfc\u822a<\/strong><\/li>\n\n<li>5.3 \u5e38\u89c1\u9009\u578b\u95ee\u9898\u901f\u67e5<\/li>\n\n<li>5.4 \u8bbe\u8ba1\u89c4\u8303\u2014\u2014\u56fd\u5bb6\u6807\u51c6\u4e0e\u9009\u578b\u516c\u5f0f<\/li>\n\n<li>5.5 \u5730\u6696\u65bd\u5de5\u4e0e\u9a8c\u6536\u89c4\u8303<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u7b2c\u516d\u7ae0\uff1a\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>6.1<\/strong> \u6309\u7528\u6237\u7c7b\u578b\u5206\u7c7b\u6848\u4f8b\uff08\u9996\u6b21\u88c5\u4fee\u3001\u6362\u623f\u5347\u7ea7\u3001\u6539\u5584\u578b\uff09<\/li>\n\n<li><strong>\u3010\u8865\u5145\u5efa\u8bae\u3011 \u589e\u52a0\u201c\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u201d\u4e13\u9879\u6848\u4f8b<\/strong><\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#dnxt07\">\u7b2c\u4e03\u7ae0\uff1a\u672a\u6765\u5c55\u671b\u4e0e\u667a\u80fd\u5347\u7ea7<\/a><\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#dnxt0701\"><strong>7.1<\/strong> \u5730\u6696\u7cfb\u7edf\u7684\u53d1\u5c55\u8d8b\u52bf<\/a><\/li>\n\n<li><a href=\"#dnxt0702\"><strong>7.2<\/strong> \u524d\u6cbf\u6280\u672f\uff08\u4e94\u6052\u7cfb\u7edf\u3001AI\u5168\u611f\uff09<\/a><\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#dnxt08\">\u7b2c\u516b\u7ae0\uff1a\u9009\u8d2d\u4e0e\u7ef4\u62a4\u5b9e\u7528\u624b\u518c<\/a><\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#dnxt0801\"><strong>8.1<\/strong> \u9009\u8d2d\u5168\u6d41\u7a0b\u4e00\u89c8\u56fe<\/a><\/li>\n\n<li><a href=\"#dnxt0802\"><strong>8.2<\/strong> \u6838\u5fc3FAQ\uff08\u7528\u6237\u6700\u5173\u5fc3\u768420\u4e2a\u95ee\u9898\uff09<\/a><\/li>\n\n<li><a href=\"#dnxt0803\"><strong>8.3<\/strong> <strong>\u5347\u7ea7\u9879\uff1a\u5173\u952e\u65bd\u5de5\u9a8c\u6536\u6307\u6807\uff08\u542b21\u5929\u517b\u62a4\u671f\u7b49\uff09<\/strong><\/a><\/li>\n\n<li><a href=\"#dnxt0804\"><strong>8.4<\/strong> \u4fdd\u517b\u65e5\u5386\u4e0e\u7ef4\u4fdd\u6e05\u5355<\/a><\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"#dnxt09\">\u7b2c\u4e5d\u7ae0\uff1a\u8fed\u4ee3\u65e5\u5fd7\u4e0e\u5185\u5bb9\u6eaf\u6e90<\/a><\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>9.1<\/strong> \u7248\u672c\u66f4\u65b0\u8bf4\u660e<\/li>\n\n<li><strong>9.2<\/strong> \u77e5\u8bc6\u5e93\u5f15\u7528\u7d22\u5f15<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<div style=\"background:#f8f8f6;padding:24px;border-radius:12px;margin-bottom:30px;\">\n<h2 style=\"color:#1a1a2e;margin-bottom:12px;\">\u6210\u90fd\u5168\u5c4b\u5730\u6696\u5b8c\u5de5\u6848\u4f8b\u805a\u5408\u603b\u89c8<\/h2>\n<p>\u9f99\u8109\u6696\u901a\u6210\u90fd\u672c\u573022\u5e74\u6696\u901a\u670d\u52a1\u5546\uff0c\u672c\u9875\u9762\u6c47\u603b\u5168\u54c1\u7c7b\u5730\u6696\u843d\u5730\u5b9e\u666f\u6848\u4f8b\uff0c\u5206\u4e3a\u6697\u88c5\u9884\u57cb\u5730\u6696\u3001\u660e\u88c5\u6696\u6c14\u7247\u5730\u6696\u3001\u83f2\u65af\u66fc\/\u535a\u4e16\/\u5a01\u80fd\/\u6797\u5185\/\u66fc\u745e\u5fb7\/\u745e\u7f8e\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\u3001\u8001\u623f\u65e7\u623f\u5730\u6696\u6539\u9020\u56db\u5927\u677f\u5757\u3002\u8986\u76d6\u9f99\u6cc9\u3001\u53cc\u6d41\u3001\u6b66\u4faf\u3001\u90eb\u90fd\u3001\u9ad8\u65b0\u5404\u5927\u697c\u76d8\u521a\u9700\u5e73\u5c42\u3001\u6539\u5584\u5927\u5e73\u5c42\u3001\u53e0\u62fc\u522b\u5885\u6237\u578b\uff0c\u6bcf\u5957\u5730\u6696\u5305\u542b\u70ed\u8d1f\u8377\u8ba1\u7b97\u3001\u7ba1\u9053\u94fa\u8bbe\u5b9e\u62cd\u3001\u80fd\u8017\u5bf9\u6bd4\u3001\u5b8c\u6574\u62a5\u4ef7\u53c2\u8003\u3002\u6210\u90fd\u5168\u57df\u53ef\u514d\u8d39\u4e0a\u95e8\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b\uff0c\u51fa\u5177\u4e13\u5c5e\u5730\u6696\u914d\u7f6e\u65b9\u6848\u3002<\/p>\n<div class=\"info-row\" style=\"display:flex;flex-wrap:wrap;gap:10px;margin-top:16px;\">\n<span style=\"background:#eef;padding:4px 12px;border-radius:20px;font-size:0.85rem;\">\u6697\u88c5\u9884\u57cb\u5730\u6696<\/span>\n<span style=\"background:#eef;padding:4px 12px;border-radius:20px;font-size:0.85rem;\">\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696<\/span>\n<span style=\"background:#eef;padding:4px 12px;border-radius:20px;font-size:0.85rem;\">\u6210\u90fd\u5404\u5c0f\u533a\u5730\u6696\u5b9e\u62cd<\/span>\n<\/div>\n<\/div>\n<section class=\"lm-hub-nav\">\n  <h2>\ud83e\udded \u76f8\u5173\u680f\u76ee\u5bfc\u822a<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=2705\">\u4e1a\u52a1\u4e2d\u5fc3<\/a> \u2014\u2014 \u5168\u4e1a\u52a1\u4ea7\u54c1\u5bfc\u822a<\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=2137\">\u6696\u6c14\u7247\u7cfb\u7edf\u00b7\u77e5\u8bc6\u5e95\u5ea7<\/a> \u2014\u2014 \u6696\u6c14\u7247\u56db\u4ee3\u6f14\u8fdb\u4e0e\u9009\u578b<\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=1395\">\u77e5\u8bc6\u4e2d\u5fc3<\/a> \u2014\u2014 \u6df1\u5ea6\u6696\u901a\u77e5\u8bc6\u6c47\u603b<\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u6848\u4f8b\u4e2d\u5fc3<\/a> \u2014\u2014 \u4e2d\u592e\u7a7a\u8c03 \/ \u5730\u6696 \/ \u6696\u6c14\u7247\u5b9e\u666f\u65b9\u6848<\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=4875\">\u552e\u540e\u5b9e\u5f55<\/a> \u2014\u2014 \u771f\u5b9e\u4e0a\u95e8\u7ef4\u4fee\u4e0e\u6392\u67e5\u6848\u4f8b<\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=3023\">\u7f51\u7ad9\u5730\u56fe<\/a> \u2014\u2014 \u5168\u7ad9\u5185\u5bb9\u4e0e\u680f\u76ee\u5bfc\u822a<\/li>\n    <li><a href=\"https:\/\/longmai-nt.com\/?page_id=625\">\u670d\u52a1\u4fdd\u969c<\/a> \u2014\u2014 \u5341\u5e74\u5305\u4fee \u00b7 \u7cbe\u5de5\u9a8c\u6536 \u00b7 \u552e\u540e\u653f\u7b56<\/li>\n  <\/ul>\n<\/section>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e00\u7ae0\uff1a\u4f60\u4e5f\u7ecf\u5386\u8fc7\u2026\u2026\uff08\u4ece\u539f\u59cb\u53d6\u6696\u5230\u73b0\u4ee3\u5730\u6696\uff09<\/h2>\n\n<h3 class=\"wp-block-heading\">1.1 \u4e24\u6761\u4e3b\u7ebf\u7684\u5e76\u884c\u6f14\u8fdb<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5730\u6696\u7684\u5386\u53f2\uff0c\u4e0d\u662f\u4e00\u6761\u5355\u7ebf\uff0c\u800c\u662f\u4e24\u6761\u4e3b\u7ebf\u4ea4\u7ec7\u63a8\u8fdb\u7684\u8fdb\u7a0b\uff1a<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u7ebf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6f14\u8fdb\u8def\u5f84<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u7ebf\u4e00\uff1a\u91c7\u6696\u65b9\u5f0f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4eba\u7528\u4ec0\u4e48\u65b9\u5f0f\u6765\u53d6\u6696\uff1f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70e4\u706b \u2192 \u6696\u6c14\u7247 \u2192 \u5730\u6696 \u2192 \u591a\u80fd\u4e92\u8865\u7cfb\u7edf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u7ebf\u4e8c\uff1a\u9700\u6c42\u4e0e\u75db\u70b9<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4eba\u5728\u53d6\u6696\u4e2d\u8ffd\u6c42\u4ec0\u4e48\u3001\u906d\u9047\u4ec0\u4e48\uff1f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u751f\u5b58\uff08\u4e0d\u51bb\u6b7b\uff09\u2192 \u5b89\u5168\uff08\u4e0d\u4e2d\u6bd2\u4e0d\u8d77\u706b\uff09\u2192 \u8212\u9002\uff08\u6e29\u8db3\u9876\u51c9\uff09\u2192 \u8282\u80fd\uff08\u8fd0\u884c\u8d39\u7528\uff09\u2192 \u4f4e\u78b3\uff08\u96f6\u6392\u653e+\u667a\u80fd\u5316\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u4e24\u6761\u4e3b\u7ebf\u50cfDNA\u53cc\u87ba\u65cb\u4e00\u6837\uff0c\u4e92\u76f8\u63a8\u52a8\u3001\u87ba\u65cb\u4e0a\u5347\u3002\u6bcf\u4e00\u79cd\u65b0\u91c7\u6696\u65b9\u5f0f\u7684\u8bde\u751f\uff0c\u90fd\u662f\u4e3a\u4e86\u89e3\u51b3\u4e0a\u4e00\u4e2a\u9636\u6bb5\u7684\u75db\u70b9\uff1b\u4f46\u6bcf\u4e00\u79cd\u65b0\u65b9\u5f0f\uff0c\u53c8\u5e26\u6765\u4e86\u65b0\u7684\u77db\u76fe\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">1.2 \u4e3b\u7ebf\u4e00\uff1a\u91c7\u6696\u65b9\u5f0f\u7684\u5343\u5e74\u6f14\u8fdb<\/h3>\n\n<h4 class=\"wp-block-heading\">\u7b2c\u4e00\u9636\u6bb5\uff1a\u539f\u59cb\u70e4\u706b\u65f6\u4ee3\uff08\u89e3\u51b3\u201c\u6709\u65e0\u201d\u95ee\u9898\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\">\u4eba\u7c7b\u6700\u65e9\u7684\u91c7\u6696\u65b9\u5f0f\u6781\u5176\u6734\u7d20\u2014\u2014\u70e7\u4e00\u5806\u706b\uff0c\u56f4\u5750\u53d6\u6696\u3002\u4ece\u77f3\u5668\u65f6\u4ee3\u7684\u7bdd\u706b\uff0c\u5230\u519c\u8015\u65f6\u4ee3\u7684\u706b\u5858\uff0c\u518d\u5230\u5317\u65b9\u519c\u6751\u7684\u706b\u7095\uff0c\u672c\u8d28\u90fd\u662f\u76f4\u63a5\u71c3\u70e7\u71c3\u6599\u83b7\u5f97\u70ed\u91cf\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u65b9\u5f0f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51fa\u73b0\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u57fa\u672c\u539f\u7406<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9\u4e0e\u5c40\u9650<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7bdd\u706b\/\u706b\u5858<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e7\u77f3\u5668\u65f6\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u660e\u706b\u76f4\u63a5\u8f90\u5c04\u6563\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c40\u90e8\uff0c\u9762\u5411\u706b\u6e90\u7684\u4e00\u9762\u6696\uff0c\u80cc\u540e\u51b7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u706b\u7095\uff08\u4e2d\u56fd\u5317\u65b9\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65b0\u77f3\u5668\u65f6\u4ee3\u665a\u671f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u70e7\u71c3\u6599\u540e\u70df\u6c14\u8d70\u7095\u4e0b\u70df\u9053\uff0c\u52a0\u70ed\u7095\u4f53\u84c4\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6574\u7095\u8868\u9762\u6e29\u6696\uff0c\u4eba\u8eba\u5367\u5176\u4e0a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7f57\u9a6c\u706b\u7095\uff08Hypocaust\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u516c\u5143\u524d1\u4e16\u7eaa<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u70ed\u70df\u6c14\u5f15\u5165\u5730\u9762\u67b6\u7a7a\u5c42\uff0c\u52a0\u70ed\u77f3\u6750\u5730\u9762<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u516c\u5171\u6d74\u5ba4\u3001\u8d35\u65cf\u4f4f\u5b85\u5168\u5c4b\u91c7\u6696<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u7089\uff08\u6b27\u6d32\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u4e16\u7eaa<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u780c\u7b51\u5728\u5899\u4f53\u5185\u7684\u71c3\u70e7\u5ba4\uff0c\u70df\u56f1\u6392\u70df\uff0c\u8f90\u5c04+\u5bf9\u6d41<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5355\u623f\u95f4\uff0c\u70ed\u7a7a\u6c14\u4e0a\u5347\uff0c\u811a\u4e0b\u4ecd\u51b7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u70e4\u706b\u65f6\u4ee3\u89e3\u51b3\u4e86\u201c\u4e0d\u51bb\u6b7b\u201d\u7684\u751f\u5b58\u9700\u6c42\uff0c\u4f46\u5e26\u6765\u4e86\u5de8\u5927\u7684\u4ee3\u4ef7\u2014\u2014<strong>\u706b\u707e\u3001\u70e7\u4f24\u3001\u4e00\u6c27\u5316\u78b3\u4e2d\u6bd2\u3001\u7a7a\u6c14\u6c61\u67d3\u3001\u6e29\u5ea6\u4e25\u91cd\u4e0d\u5747<\/strong>\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">\u7b2c\u4e8c\u9636\u6bb5\uff1a\u96c6\u4e2d\u4f9b\u6696\u4e0e\u6696\u6c14\u7247\u65f6\u4ee3\uff08\u89e3\u51b3\u201c\u5b89\u5168+\u4fbf\u5229\u201d\u95ee\u9898\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e8b\u4ef6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u610f\u4e49<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1870s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7f8e\u56fd\u5f00\u59cb\u51fa\u73b0\u96c6\u4e2d\u4f9b\u6696\u7cfb\u7edf\uff08\u84b8\u6c7d\u7ba1\u9053\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90\u96c6\u4e2d\u5316\uff0c\u672b\u7aef\u5206\u6563\u5316<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1907\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u82f1\u56fd\u5de5\u7a0b\u5e08\u53d1\u660e\u5faa\u73af\u70ed\u6c34\u5730\u677f\u4f9b\u6696\u7cfb\u7edf\uff08\u91d1\u5c5e\u7ba1\u9053\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u73b0\u4ee3\u6c34\u5730\u6696\u96cf\u5f62\u8bde\u751f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1920s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94f8\u94c1\u6696\u6c14\u7247\uff08\u6563\u70ed\u5668\uff09\u5728\u6b27\u6d32\u666e\u53ca<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672b\u7aef\u8bbe\u5907\u6807\u51c6\u5316\uff0c\u8d70\u8fdb\u5343\u5bb6\u4e07\u6237<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1950s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u56fd\u5317\u65b9\u57ce\u5e02\u5f00\u59cb\u5efa\u8bbe\u96c6\u4e2d\u4f9b\u70ed\u7ba1\u7f51<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u89c4\u6a21\u96c6\u4e2d\u4f9b\u6696\u8986\u76d6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u6696\u6c14\u7247\u7684\u51fa\u73b0\u89e3\u51b3\u4e86\u70e4\u706b\u7684\u51e0\u5927\u75db\u70b9\uff1a\u4e0d\u518d\u6709\u660e\u706b\u5371\u9669\u3001\u4e0d\u518d\u6709\u70df\u5c18\u548cCO\u4e2d\u6bd2\u3001\u6bcf\u4e2a\u623f\u95f4\u90fd\u80fd\u72ec\u7acb\u4f9b\u6696\u3002\u4f46\u5b83\u4ecd\u7136\u5b58\u5728 <strong>\u201c\u5934\u70ed\u811a\u51b7\u201d\u7684\u56fa\u6709\u7f3a\u9677<\/strong>\u2014\u2014\u70ed\u7a7a\u6c14\u4e0a\u5347\uff0c\u5929\u82b1\u677f\u9644\u8fd1\u6700\u6696\uff0c\u5730\u9762\u6700\u51b7\uff0c\u4e0d\u7b26\u5408\u4eba\u4f53\u751f\u7406\u8212\u9002\u9700\u6c42\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">\u7b2c\u4e09\u9636\u6bb5\uff1a\u73b0\u4ee3\u5730\u6696\u65f6\u4ee3\uff08\u89e3\u51b3\u201c\u8212\u9002\u201d\u95ee\u9898\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e8b\u4ef6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u610f\u4e49<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1970s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u77f3\u6cb9\u5371\u673a\u63a8\u52a8\u8282\u80fd\u6280\u672f\u7814\u53d1\uff1bPEX\/PB\u5851\u6599\u7ba1\u9053\u66ff\u4ee3\u91d1\u5c5e\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u4e86\u91d1\u5c5e\u7ba1\u9053\u8150\u8680\u548c\u65bd\u5de5\u96be\u9898\uff0c\u5730\u6696\u4ece\u9ad8\u7aef\u8d70\u5411\u6c11\u7528<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1980s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6b27\u6d32\u5730\u6696\u5927\u9762\u79ef\u666e\u53ca<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e29\u8db3\u9876\u51c9\u6210\u4e3a\u65b0\u8212\u9002\u6807\u51c6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1990s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u6280\u672f\u5f15\u5165\u4e2d\u56fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ece\u5317\u65b9\u6269\u5c55\u5230\u957f\u6c5f\u6d41\u57df<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2000s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7535\u5730\u6696\uff08\u53d1\u70ed\u7535\u7f06\uff09\u5728\u56fd\u5185\u5174\u8d77<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e0\u9700\u9505\u7089\uff0c\u5b89\u88c5\u66f4\u7075\u6d3b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2010s<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u6c14\u80fd\u70ed\u6cf5\u4e24\u8054\u4f9b\u5728\u5730\u6696\u5e02\u573a\u5d1b\u8d77<\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u5ea6\u7535\u642c3\u5ea6\u70ed\uff0c\u8fd0\u884c\u8d39\u7528\u5927\u5e45\u4e0b\u964d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u7b2c\u56db\u9636\u6bb5\uff1a\u591a\u80fd\u4e92\u8865\u65f6\u4ee3\uff08\u89e3\u51b3\"\u8282\u80fd+\u4f4e\u78b3\"\u95ee\u9898\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\">\u5f53\u524d\u5730\u6696\u6b63\u5728\u4ece\"\u5355\u4e00\u70ed\u6e90\"\u8d70\u5411\"\u591a\u80fd\u4e92\u8865\"\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65f6\u95f4<\/th><th>\u4e8b\u4ef6<\/th><th>\u610f\u4e49<\/th><\/tr><\/thead><tbody><tr><td>2015\u5e74<\/td><td>\"\u7164\u6539\u7535\"\u653f\u7b56\u63a8\u52a8\u7a7a\u6c14\u80fd\u70ed\u6cf5\u8fdb\u5165\u5317\u65b9\u91c7\u6696<\/td><td>\u6e05\u6d01\u80fd\u6e90\u66ff\u4ee3\u71c3\u7164<\/td><\/tr><tr><td>2018\u5e74<\/td><td>\u65e5\u7acb\u63a8\u51fa\u667a\u4eab\u5929\u6c1f\u5730\u6c34\u4e00\u4f53\u673a<\/td><td>\u6c1f\u673a\u5236\u51b7+\u6c34\u7cfb\u7edf\u91c7\u6696\u878d\u5408<\/td><\/tr><tr><td>2020\u5e74<\/td><td>\u56fd\u5bb6\"\u53cc\u78b3\"\u76ee\u6807\u63d0\u51fa<\/td><td>\u96f6\u78b3\u91c7\u6696\u6210\u4e3a\u65b0\u65b9\u5411<\/td><\/tr><tr><td>2023\u5e74<\/td><td>\u4e2d\u56fd\u7a7a\u6c14\u80fd\u91c7\u6696\u5e02\u573a\u89c4\u6a21\u7a81\u7834260\u4ebf\u5143<\/td><td>\u5e74\u589e\u901f\u8d8520%<\/td><\/tr><tr><td>2025\u5e74<\/td><td>AI\u667a\u80fd\u8054\u63a7+\u5149\u50a8\u70ed\u4e00\u4f53\u5316\u8fdb\u5165\u8bd5\u70b9<\/td><td>\u6309\u9700\u4f9b\u6696\uff0c\u5149\u4f0f\u9a71\u52a8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">1.3 \u4e3b\u7ebf\u4e8c\uff1a\u9700\u6c42\u4e0e\u75db\u70b9\u7684\u56db\u5c42\u5347\u7ea7<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9700\u6c42\u5c42\u7ea7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u8bc9\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66fe\u88ab\u89e3\u51b3\u7684\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e26\u6765\u7684\u65b0\u75db\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u5e94\u7684\u6280\u672f\u6f14\u8fdb<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7b2c\u4e00\u5c42\uff1a\u751f\u5b58<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u51bb\u6b7b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u706b\u707e\u3001\u70e7\u4f24\u3001CO\u4e2d\u6bd2\u3001\u7a7a\u6c14\u6c61\u67d3\u3001\u6e29\u5ea6\u4e0d\u5747<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ece\u660e\u706b\u5230\u5c01\u95ed\u71c3\u70e7\uff08\u58c1\u7089\/\u7089\u5b50\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7b2c\u4e8c\u5c42\uff1a\u5b89\u5168+\u8212\u9002<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5747\u5300\u6e29\u6696\u3001\u5065\u5eb7\u5b89\u5168<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5934\u70ed\u811a\u51b7\u3001\u7a7a\u6c14\u5e72\u71e5\u3001\u5c40\u90e8\u8fc7\u70ed\u3001\u626c\u5c18<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u7528\u9ad8\u3001\u7cfb\u7edf\u4e0d\u7a33\u5b9a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ece\u6696\u6c14\u7247\u5230\u5730\u6696\uff08\u8f90\u5c04\u6563\u70ed\uff0c\u6e29\u8db3\u9876\u51c9\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7b2c\u4e09\u5c42\uff1a\u7ecf\u6d4e+\u7a33\u5b9a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u7528\u4f4e\u3001\u7cfb\u7edf\u7a33\u5b9a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u8017\u9ad8\u3001\u9891\u7e41\u542f\u505c\u3001\u5927\u9a6c\u62c9\u5c0f\u8f66\u3001\u70ed\u5f97\u6162<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u62a4\u590d\u6742\u3001\u7cfb\u7edf\u8150\u8680<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd+\u53d8\u9891+\u8054\u52a8\u63a7\u5236+\u6c34\u529b\u5e73\u8861<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7b2c\u56db\u5c42\uff1a\u4f4e\u78b3+\u667a\u80fd<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u96f6\u78b3\u6392\u653e\u3001\u514d\u7ef4\u62a4\u3001AI\u81ea\u63a7<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u62a4\u9ebb\u70e6\u3001\u7cfb\u7edf\u8150\u8680\u3001\u552e\u540e\u65e0\u4fdd\u969c\u3001\u78b3\u6392\u653e\u7126\u8651<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\u95e8\u69db\u9ad8\u3001\u521d\u6295\u6210\u672c\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5149\u50a8\u70ed\u4e00\u4f53\u5316\u3001AI\u70ed\u80fd\u7ba1\u5bb6\u3001\u963b\u6c27\u7ba1+\u667a\u80fd\u8054\u52a8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u201c\u8fd9\u4e0d\u662f\u6280\u672f\u7684\u5806\u780c\uff0c\u662f\u4eba\u7684\u9700\u6c42\u4ece\u2018\u51ac\u5929\u4e0d\u6328\u51bb\u2019\u5230\u2018\u56db\u5b63\u4f4f\u5f97\u8212\u670d\u2019\u7684\u81ea\u7136\u6f14\u8fdb\u3002\u201d<\/strong><\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">1.4 \u73b0\u4ee3\u5730\u6696\u7684\u6838\u5fc3\u4f18\u52bf<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u52bf\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u7279\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u6696\u6c14\u7247\/\u7a7a\u8c03<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f9d\u636e\u6765\u6e90<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u517b\u751f\u8212\u9002<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u91cf\u81ea\u4e0b\u800c\u4e0a\uff0c\u6e29\u8db3\u9876\u51c9\uff0c\u7b26\u5408\u4e2d\u533b\u201c\u5934\u51c9\u811a\u70ed\u201d\u4fdd\u5065\u7406\u5ff5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247\u70ed\u7a7a\u6c14\u4e0a\u5347\uff0c\u5934\u70ed\u811a\u51b7<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/longmai-nt.com\/?page_id=1233\">\u65e5\u7acb\u6c34\u5885\u9002<\/a>\u3001JGJ 142-2012<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a33\u5b9a\u6052\u6e29<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u56de\u586b\u5c42\u84c4\u70ed\u80fd\u529b\u5f3a\uff0c\u5173\u7089\u540e2-3\u5c0f\u65f6\u4ecd\u4fdd\u6e29\uff0c\u5ba4\u6e29\u6ce2\u52a8\u5c0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247\u505c\u5373\u51b7\uff0c\u6e29\u5ea6\u6ce2\u52a8\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e8c\u7bc7\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6696\u800c\u4e0d\u5e72<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ee5\u6c34\u4e3a\u5a92\u4ecb\u8f90\u5c04\u6563\u70ed\uff0c\u65e0\u6c14\u6d41\u76f4\u5439\uff0c\u4e0d\u6613\u5e26\u8d70\u76ae\u80a4\u6c34\u5206<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u8c03\/\u6696\u98ce\u673a\u5439\u98ce\u5e72\u71e5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e8c\u7bc7\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6d01\u51c0\u7f8e\u89c2<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u8def\u9690\u85cf\u4e8e\u5730\u9762\u4e0b\uff0c\u4e0d\u5360\u5899\u9762\u7a7a\u95f4\uff0c\u65e0\u626c\u5c18<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6696\u6c14\u7247\u5360\u5899\u9762\uff0c\u79ef\u7070\u96be\u6e05\u7406<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e8c\u7bc7\u300b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">1.5 \u5730\u6696\u7cfb\u7edf\u56db\u8981\u7d20\uff1a\u5730\u6696\u662f\u201c\u7cfb\u7edf\u201d\u800c\u975e\u201c\u8bbe\u5907\u201d<\/h3>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u89c2\u5ff5<\/strong>\uff1a\u4e00\u5957\u597d\u7684\u5730\u6696\uff0c\u4e0d\u53d6\u51b3\u4e8e\u5355\u4e00\u8bbe\u5907\u7684\u597d\u574f\uff0c\u800c\u53d6\u51b3\u4e8e\u56db\u4e2a\u8981\u7d20\u7684\u534f\u540c\u5339\u914d\u3002<\/p>\n<\/blockquote>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8981\u7d20<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6696\u901a\u5bf9\u5e94<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6846\u67b6\u5bf9\u5e94<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u95ee\u9898<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u6e90<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u7ed9\u4fa7\uff08\u4ea7\u70ed\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u7684\u70ed\u591f\u4e0d\u591f\uff1f\u4f1a\u4e0d\u4f1a\u4ea7\u592a\u591a\uff1f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8f93\u914d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u9053\u3001\u6c34\u6cf5\u3001\u5206\u96c6\u6c34\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7269\u6d41\uff08\u8fd0\u70ed\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u7684\u70ed\u80fd\u4e0d\u80fd\u5168\u90e8\u62c9\u8d70\uff1f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u672b\u7aef<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u76d8\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d88\u8d39\u4fa7\uff08\u7528\u70ed\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62c9\u6765\u7684\u70ed\u80fd\u4e0d\u80fd\u5168\u90e8\u6563\u6389\uff1f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e29\u63a7\u5668\u3001\u8054\u52a8\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u9700\u5339\u914d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ec0\u4e48\u65f6\u5019\u8be5\u4ea7\u3001\u4ec0\u4e48\u65f6\u5019\u8be5\u505c\uff1f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u603b\u7ed3<\/strong>\uff1a\u4ea7\u7684\u70ed\u62c9\u4e0d\u8d70\uff0c\u70ed\u6e90\u81ea\u635f\uff1b\u62c9\u6765\u7684\u70ed\u6563\u4e0d\u6389\uff0c\u5bb6\u91cc\u4e0d\u70ed\u3002<strong>\u529f\u7387\u5339\u914d\u6bd4\u529f\u7387\u5927\u66f4\u91cd\u8981\u3002<\/strong><\/p>\n<\/blockquote>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e8c\u7ae0\uff1a\u62c5\u5fc3\u75db\u70b9\u4e0e\u8bef\u533a\uff08\u8ba4\u77e5\u5148\u884c\uff09<\/h2>\n\n<p class=\"wp-block-paragraph\">\u5728\u6df1\u5165\u4e86\u89e3\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u548c\u63a7\u5236\u8fd9\u4e9b\u6280\u672f\u7ec6\u8282\u4e4b\u524d\uff0c\u6211\u4eec\u5fc5\u987b\u5148\u5ba1\u89c6\u4e00\u4e2a\u6839\u672c\u95ee\u9898\uff1a<strong>\u7528\u6237\u771f\u6b63\u62c5\u5fc3\u7684\u662f\u4ec0\u4e48\uff1f\u5e38\u89c1\u7684\u8ba4\u77e5\u8bef\u533a\u662f\u4ec0\u4e48\uff1f<\/strong> \u8fd9\u4e00\u7ae0\uff0c\u5c31\u662f\u4e3a\u7528\u6237\u201c\u6253\u9884\u9632\u9488\u201d\uff0c\u5e2e\u52a9\u4ed6\u4eec\u5728\u4fe1\u606f\u4e0d\u5bf9\u79f0\u7684\u5e02\u573a\u4e2d\uff0c\u5efa\u7acb\u6b63\u786e\u7684\u8ba4\u77e5\u6846\u67b6\uff0c\u907f\u514d\u4ece\u4e00\u5f00\u59cb\u5c31\u8d70\u5165\u9519\u8bef\u7684\u65b9\u5411\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">2.1 \u7528\u6237\u4e94\u5927\u6838\u5fc3\u8bc9\u6c42\u4e0e\u56db\u5927\u75db\u70b9<\/h3>\n\n<h4 class=\"wp-block-heading\">\u4e94\u5927\u6838\u5fc3\u8bc9\u6c42<\/h4>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u77e5\u8bc6\u5e93\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e09\u7bc7\uff1a\u6696\u901a\u7528\u6237\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790\u300b\u53ca\u5ba2\u6237\u6c9f\u901a\u8bb0\u5f55\uff0c\u4efb\u4f55\u4e00\u4f4d\u5730\u6696\u7528\u6237\uff0c\u65e0\u8bba\u6237\u578b\u5927\u5c0f\u3001\u9884\u7b97\u9ad8\u4f4e\uff0c\u6700\u7ec8\u8ffd\u6c42\u7684\u5176\u5b9e\u90fd\u662f\u4ee5\u4e0b\u4e94\u4e2a\u6838\u5fc3\u8bc9\u6c42\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bc9\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7528\u6237\u8bed\u8a00\uff08\u539f\u8bdd\u793a\u4f8b\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u8ba1\u76ee\u6807<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8212\u9002<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u4e0d\u8981\u5934\u70ed\u811a\u51b7\u201d\u3001\u201c\u4e0d\u5e72\u71e5\u201d\u3001\u201c\u6e29\u5ea6\u80fd\u5747\u5300\u70b9\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e29\u8db3\u9876\u51c9\uff0c\u5ba4\u6e29\u5747\u5300\uff0c\u4e0d\u5e72\u71e5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a33\u5b9a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u522b\u4e09\u5929\u4e24\u5934\u574f\u201d\u3001\u201c\u522b\u8001\u662f\u4e00\u4f1a\u5f00\u4e00\u4f1a\u5173\u70e6\u6b7b\u4e86\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u6545\u969c\u7387\u4f4e\uff0c\u6c34\u6e29\/\u5ba4\u6e29\u7a33\u5b9a<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8282\u80fd<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u4e00\u4e2a\u6708\u71c3\u6c14\u8d39\u4e0a\u5343\uff0c\u4e5f\u4e0d\u77e5\u9053\u82b1\u54ea\u513f\u53bb\u4e86\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u7528\u53ef\u63a7\uff0c\u907f\u514d\u65e0\u6548\u4ea7\u70ed<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5065\u5eb7<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u6709\u5c0f\u5b69\/\u8001\u4eba\uff0c\u6015\u7a7a\u6c14\u4e0d\u597d\u201d\u3001\u201c\u522b\u50cf\u7a7a\u8c03\u4e00\u6837\u5439\u98ce\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e0\u626c\u5c18\uff0c\u65e0\u98ce\u611f\uff0c\u6750\u6599\u73af\u4fdd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4fbf\u6377<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u201c\u80fd\u4e0d\u80fd\u624b\u673a\u63a7\u5236\u201d\u3001\u201c\u64cd\u4f5c\u80fd\u7b80\u5355\u70b9\u5417\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u667a\u80fd\u5316\u63a7\u5236\uff0c\u968f\u65f6\u968f\u5730\u64cd\u4f5c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u56db\u5927\u6838\u5fc3\u75db\u70b9<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u75db\u70b9<\/th><th>\u5178\u578b\u8868\u73b0<\/th><th>\u6839\u56e0\u5206\u6790<\/th><\/tr><\/thead><tbody><tr><td><strong>\u8fd0\u884c\u8d39\u7528\u6781\u9ad8<\/strong><\/td><td>80\u33a1\u6708\u8d39\u8d851000\u5143\uff1b\u5927\u6237\u578b\u6708\u71c3\u6c14\u8d395000+<\/td><td>\u2460\u9505\u7089\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u2014\u2014\u4e3a\u6ee1\u8db3\u70ed\u6c34\u9700\u6c42\u9009\u5927\u529f\u7387\uff0c\u91c7\u6696\u5b63\u6700\u5c0f\u8f93\u51fa\u4ecd\u8fdc\u8d85\u5b9e\u9645\u9700\u6c42\uff1b\u2461\u8f93\u914d\"\u5c0f\u6d41\u91cf\u5927\u6e29\u5dee\"\u2014\u2014\u6c34\u6cf5\u9009\u578b\u4e0d\u5f53\uff1b\u2462\u63a7\u5236\"\u76f2\u76ee\u70e7\"\u2014\u2014\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u672a\u8054\u52a8\uff1b\u2463\u96f6\u51b7\u6c34\u65b9\u6848\u65e0\u6548\u70ed\u635f\u5931<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u4e0d\u7a33\u5b9a\uff0c\u9891\u7e41\u542f\u505c<\/strong><\/td><td>\u9505\u7089\u9891\u7e41\u70b9\u706b\u3001\u505c\u673a\uff0c\u566a\u97f3\u70e6\u4eba\uff0c\u5ba4\u6e29\u6ce2\u52a8\u5927<\/td><td>\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff088-10kW\uff09\u8fdc\u8d85\u5c0f\u9762\u79ef\u5b9e\u9645\u9700\u6c42\uff08\u7ea65kW\uff09\uff1b\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u672a\u5b9e\u73b0\u8054\u52a8\u63a7\u5236<\/td><\/tr><tr><td><strong>\u70ed\u5f97\u6162<\/strong><\/td><td>\u5f00\u542f\u97002-3\u5c0f\u65f6\u5730\u9762\u624d\u6709\u6e29\u5ea6<\/td><td>\u5730\u6696\u5c5e\u50a8\u70ed\u5f0f\u91c7\u6696\uff0c\u9700\u9884\u70ed\u6df7\u51dd\u571f\u56de\u586b\u5c42\uff08\u7ea650mm\u539a\uff09\uff1b\u9996\u6b21\u5347\u6e29\u5fc5\u987b\u514b\u670d\u5efa\u7b51\u84c4\u70ed<\/td><\/tr><tr><td><strong>\u7ef4\u62a4\u9ebb\u70e6\u4e0e\u7cfb\u7edf\u8150\u8680<\/strong><\/td><td>\u635f\u574f\u9700\u7834\u574f\u5730\u9762\u7ef4\u4fee\uff1b\u51fa\u73b0\u9ed1\u6c34\u3001\u5f02\u5473<\/td><td>\u9690\u853d\u5de5\u7a0b\u7ef4\u4fee\u6210\u672c\u6781\u9ad8\uff1b\u672a\u4f7f\u7528\u963b\u6c27\u7ba1\u5bfc\u81f4\u6c27\u6c14\u6e17\u900f\u2192\u7ba1\u9053\u5185\u58c1\u6c27\u5316\u8150\u8680\u2192\u9ed1\u6c34+\u7ed3\u57a2<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u75db\u70b9-\u65b9\u6848\u5feb\u901f\u6620\u5c04\u8868<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u75db\u70b9<\/th><th>\u6839\u56e0<\/th><th>\u5efa\u8bae\u65b9\u6848<\/th><th>\u5bf9\u60a8\u7684\u597d\u5904<\/th><\/tr><\/thead><tbody><tr><td><strong>\u8fd0\u884c\u8d39\u7528\u6781\u9ad8<\/strong><\/td><td>\u9505\u7089\"\u5927\u9a6c\u62c9\u5c0f\u8f66\"\u2014\u2014\u4e3a\u6ee1\u8db3\u70ed\u6c34\u9700\u6c42\u9009\u5927\u529f\u7387\uff1b\u8f93\u914d\"\u5c0f\u6d41\u91cf\u5927\u6e29\u5dee\"\uff1b\u63a7\u5236\"\u76f2\u76ee\u70e7\"<\/td><td>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u66ff\u4ee3\u71c3\u6c14\u58c1\u6302\u7089\uff1b\u6216\u51b7\u51dd\u7089+\u6c34\u529b\u5e73\u8861+\u8054\u52a8\u63a7\u5236+\u6c14\u5019\u8865\u507f<\/td><td>\u8fd0\u884c\u8d39\u964d\u81f3\u71c3\u6c1430-50%\uff0c\u7cfb\u7edf\u542f\u505c\u6b21\u6570\u51cf\u5c1170%+<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u9891\u7e41\u542f\u505c<\/strong><\/td><td>\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u8fdc\u8d85\u5c0f\u9762\u79ef\u5b9e\u9645\u9700\u6c42\uff1b\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u672a\u8054\u52a8<\/td><td>\u6362\u53d8\u9891\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa3-4kW\uff09+ \u6e29\u63a7\u5668\u8054\u52a8\u9505\u7089\u63a7\u5236<\/td><td>\u6d88\u9664\u76f2\u76ee\u70e7\uff0c\u5ba4\u6e29\u7a33\u5b9a\uff0c\u8bbe\u5907\u635f\u8017\u5927\u5e45\u964d\u4f4e<\/td><\/tr><tr><td><strong>\u70ed\u6c34\u4e0e\u91c7\u6696\u51b2\u7a81<\/strong><\/td><td>\u4e24\u7528\u7089\u8bbe\u8ba1\u77db\u76fe\uff1a\u4e3a\u6ee1\u8db3\u5927\u6d41\u91cf\u70ed\u6c34\u9009\u5927\u529f\u7387\u2192\u91c7\u6696\u5b63\u6700\u5c0f\u8f93\u51fa\u8fdc\u8d85\u9700\u6c42<\/td><td>\u7cfb\u7edf\u7089\uff08\u5355\u91c7\u6696\uff09+ \u72ec\u7acb\u70ed\u6c34\u5668\/\u70ed\u6c34\u7bb1\u2014\u2014\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u8bbe\u8ba1<\/td><td>\u91c7\u6696\u9ad8\u6548+\u70ed\u6c34\u7a33\u5b9a\uff0c\u544a\u522b\u5ffd\u51b7\u5ffd\u70ed<\/td><\/tr><tr><td><strong>\u70ed\u5f97\u6162<\/strong><\/td><td>\u5730\u6696\u5c5e\u50a8\u70ed\u5f0f\u91c7\u6696\uff0c\u9700\u9884\u70ed\u6df7\u51dd\u571f\u56de\u586b\u5c42<\/td><td>\u667a\u80fd\u9884\u70ed\uff1a\u56de\u5bb6\u524d1\u5c0f\u65f6\u8fdc\u7a0b\u5f00\u542f\uff1b\u65e5\u5e38\u6052\u6e29\u8fd0\u884c\u4e0d\u5173<\/td><td>\u56de\u5bb6\u5373\u4eab\u6e29\u6696\uff0c\u65e0\u9700\u7b49\u5f852-3\u5c0f\u65f6<\/td><\/tr><tr><td><strong>\u7ef4\u62a4\u9ebb\u70e6\u4e0e\u7cfb\u7edf\u8150\u8680<\/strong><\/td><td>\u9690\u853d\u5de5\u7a0b\u7ef4\u4fee\u6210\u672c\u6781\u9ad8\uff1b\u672a\u4f7f\u7528\u963b\u6c27\u7ba1\u2192\u7ba1\u9053\u6c27\u5316\u8150\u8680<\/td><td>\u9009\u7528\u963b\u6c27\u7ba1\uff08EVOH\u963b\u6c27\u5c42\uff0cDIN 4726\u6807\u51c6\uff09+ \u5b9a\u671f\u7ba1\u9053\u6e05\u6d17<\/td><td>\u7ba1\u905315\u5e74\u4ee5\u4e0a\u6d01\u51c0\uff0c\u7701\u4e0b\u6570\u5343\u5143\u6e05\u6d17\u8d39<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">2.2 \u516d\u5927\u5e38\u89c1\u8bef\u533a\u4e0e\u771f\u76f8<\/h3>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e09\u7bc7\u300b\u53ca\u300a\u5730\u6696\u805a\u5408\u9875\u4e0a\u4e0b\u518c\u300b\uff0c\u4ee5\u4e0b\u662f\u6d88\u8d39\u8005\u5728\u9009\u8d2d\u5730\u6696\u65f6\u6700\u5e38\u9677\u5165\u7684\u516d\u5927\u8ba4\u77e5\u8bef\u533a\u53ca\u5176\u80cc\u540e\u7684\u771f\u76f8\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">\u8bef\u533a\u4e00\uff1a\u201c\u9505\u7089\u529f\u7387\u8d8a\u5927\u8d8a\u597d\u201d<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9519\u8bef\u8ba4\u77e5<\/strong>\uff1a\u8ba4\u4e3a\u5927\u529f\u7387\u9505\u7089\u610f\u5473\u7740\u201c\u70ed\u5f97\u66f4\u5feb\u201d\u3001\u201c\u70ed\u91cf\u66f4\u8db3\u201d\uff0c\u662f\u7cfb\u7edf\u5f3a\u5927\u7684\u8c61\u5f81\u3002<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u529f\u7387\u5339\u914d\u6bd4\u529f\u7387\u5927\u66f4\u91cd\u8981\u3002\u5730\u6696\u662f\u201c\u4f4e\u6e29\u6162\u7096\u201d\uff0c\u800c\u975e\u201c\u9ad8\u6e29\u7206\u7092\u201d\u3002\u9505\u7089\u529f\u7387\u8fc7\u5927\uff0c\u5176\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff08\u901a\u5e38\u4e3a8-10kW\uff09\u4f1a\u8fdc\u8d85\u672b\u7aef\u5b9e\u9645\u9700\u6c42\uff08\u5c0f\u6237\u578b\u91c7\u6696\u53ef\u80fd\u53ea\u97003-5kW\uff09\uff0c\u5bfc\u81f4\u6c34\u6e29\u5feb\u901f\u8fbe\u6807\u540e\u505c\u673a\u3001\u5438\u5165\u51b7\u7a7a\u6c14\u540e\u518d\u6b21\u70b9\u706b\uff0c\u9677\u5165\u201c\u9891\u7e41\u542f\u505c\u201d\u7684\u6076\u6027\u5faa\u73af\u3002\u8fd9\u4e0d\u4ec5\u6d6a\u8d39\u71c3\u6c14\uff0c\u66f4\u4f1a\u7f29\u77ed\u8bbe\u5907\u5bff\u547d\u3002<\/li>\n\n<li><strong>\u5185\u94fe<\/strong>\uff1a\u6df1\u5165\u4e86\u89e3\u529f\u7387\u4e0d\u5339\u914d\u7684\u5371\u5bb3\uff0c\u8bf7\u89c1 <strong>3.1\u8282 <a href=\"https:\/\/longmai-nt.com\/?page_id=3872\">\u9505\u7089\u5de5\u4f5c\u539f\u7406<\/a>\u4e0e\u75db\u70b9\u5185\u94fe<\/strong>\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u8bef\u533a\u4e8c\uff1a\u201c\u51b7\u51dd\u7089\u4e70\u56de\u6765\u5c31\u8282\u80fd\u201d<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9519\u8bef\u8ba4\u77e5<\/strong>\uff1a\u8ba4\u4e3a\u53ea\u8981\u4e70\u4e86\u6807\u79f0\u70ed\u6548\u7387\u8d85\u8fc7100%\u7684\u51b7\u51dd\u7089\uff0c\u5c31\u80fd\u81ea\u52a8\u7701\u6c14\u3002<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u51b7\u51dd\u7089\u7684\u9ad8\u6548\u5fc5\u987b\u5efa\u7acb\u5728\u4e24\u4e2a\u57fa\u7840\u4e0a\uff1a<strong>\u4f4e\u6e29\u7cfb\u7edf<\/strong>\uff08\u4f9b\u6c34\u6e29\u5ea6\u226455\u2103\uff0c\u751a\u81f3\u226450\u2103\uff09\u548c<strong>\u7cfb\u7edf\u8bbe\u8ba1\u5230\u4f4d<\/strong>\uff08\u6c34\u529b\u5e73\u8861\u3001\u8054\u52a8\u63a7\u5236\u3001\u5927\u6d41\u91cf\uff09\u3002\u5982\u679c\u4ecd\u7528\u4f20\u7edf\u9ad8\u6e29\u6696\u6c14\u7247\uff08\u6c34\u6e2970-80\u2103\uff09\uff0c\u51b7\u51dd\u7089\u7684\u51b7\u51dd\u56de\u6536\u529f\u80fd\u5c06\u65e0\u6cd5\u542f\u52a8\uff0c\u5176\u5b9e\u9645\u6548\u7387\u4e0e\u666e\u901a\u7089\u65e0\u5f02\uff0c\u751a\u81f3\u53ef\u80fd\u56e0\u7cfb\u7edf\u914d\u7f6e\u4e0d\u5408\u7406\u800c\u66f4\u9ad8\u3002\u591a\u82b1\u7684\u94b1\u5c31\u767d\u8d39\u4e86\u3002<\/li>\n\n<li><strong>\u5185\u94fe<\/strong>\uff1a\u5982\u4f55\u6b63\u786e\u8bbe\u8ba1\u4f4e\u6e29\u7cfb\u7edf\uff0c\u8bf7\u89c1 <strong>4.1\u8282 \u8f93\u914d\u7cfb\u7edf<\/strong>\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u8bef\u533a\u4e09\uff1a\u201c\u591a\u5f00\u6696\u6c14\u7247\u66f4\u8282\u80fd\u201d<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9519\u8bef\u8ba4\u77e5<\/strong>\uff1a\u8ba4\u4e3a\u4e3a\u4e86\u7701\u6c14\u5c31\u53ea\u5f00\u6700\u9700\u8981\u7684\u623f\u95f4\uff0c\u628a\u5176\u4ed6\u623f\u95f4\u7684\u6696\u6c14\u7247\u5173\u6389\u3002<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u8fd9\u4e2a\u8bf4\u6cd5\u8981\u5206\u60c5\u51b5\u770b\u3002\u5bf9\u4e8e\u666e\u901a\u58c1\u6302\u7089\uff0c\u591a\u5f00\u7684\u623f\u95f4\u6570\u80fd\u6d88\u8017\u66f4\u591a\u70ed\u91cf\uff0c\u4ece\u800c<strong>\u51cf\u5c11\u9505\u7089\u7684\u9891\u7e41\u542f\u505c<\/strong>\uff0c\u4ece\u8fd9\u4e2a\u89d2\u5ea6\u770b\u662f\u201c\u8282\u80fd\u201d\u7684\uff1b\u4f46\u5982\u679c\u5f00\u7740\u7684\u623f\u95f4\u662f\u65e0\u4eba\u4f7f\u7528\u7684\uff0c\u90a3\u672c\u8eab\u5c31\u662f\u4e00\u79cd\u6d6a\u8d39\u3002<strong>\u6240\u4ee5\uff0c\u6b63\u786e\u7684\u505a\u6cd5\u662f\uff1a\u6309\u9700\u5f00\u95ed\uff0c\u914d\u5408\u53d8\u9891\u9505\u7089\u6216\u50a8\u70ed\u7cfb\u7edf\uff0c\u800c\u975e\u65e0\u8111\u5730\u5168\u5f00\u6216\u5168\u5173\u3002<\/strong><\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u8bef\u533a\u56db\uff1a\u201c\u5730\u6696\u7ba1\u5b50\u94fa\u5f97\u8d8a\u5bc6\u8d8a\u70ed\u201d<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9519\u8bef\u8ba4\u77e5<\/strong>\uff1a\u8ba4\u4e3a\u76d8\u7ba1\u95f4\u8ddd\u8d8a\u5c0f\uff0c\u5355\u4f4d\u9762\u79ef\u6563\u70ed\u91cf\u8d8a\u5927\uff0c\u623f\u95f4\u5c31\u8d8a\u70ed\u3002<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u5730\u6696\u662f\u7cfb\u7edf\uff0c\u800c\u975e\u5355\u4e00\u8bbe\u5907\u3002\u76d8\u7ba1\u95f4\u8ddd\u9700\u8981\u6839\u636e\u6bcf\u4e2a\u623f\u95f4\u7684<strong>\u70ed\u8d1f\u8377<\/strong>\u7cbe\u786e\u8ba1\u7b97\u3002\u8fc7\u5bc6\u7684\u95f4\u8ddd\u4e0d\u4ec5\u6d6a\u8d39\u7ba1\u6750\uff0c\u66f4\u5bb9\u6613\u5bfc\u81f4<strong>\u6c34\u6d41\u77ed\u8def<\/strong>\u2014\u2014\u8fdb\u6c34\u548c\u51fa\u6c34\u4e4b\u95f4\u7684\u538b\u5dee\u6781\u5c0f\uff0c\u70ed\u6c34\u90fd\u8d70\u77ed\u56de\u8def\uff0c\u672b\u7aef\u73af\u8def\u4e0d\u70ed\uff0c\u53cd\u800c\u9020\u6210\u6563\u70ed\u4e0d\u5747\u3002\u76d8\u7ba1\u8bbe\u8ba1\u201c\u6070\u5230\u597d\u5904\u201d\u5373\u53ef\u3002<\/li>\n\n<li><strong>\u5185\u94fe<\/strong>\uff1a\u5982\u4f55\u7cbe\u786e\u8ba1\u7b97\u8d1f\u8377\u5e76\u9009\u62e9\u7ba1\u95f4\u8ddd\uff0c\u8bf7\u89c1 <strong>5.2\u8282 \u70ed\u8d1f\u8377\u8ba1\u7b97<\/strong>\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u8bef\u533a\u4e94\uff1a\u201c\u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u662f\u6b63\u5e38\u7684\u201d<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9519\u8bef\u8ba4\u77e5<\/strong>\uff1a\u8ba4\u4e3a\u9505\u7089\u5728\u8fd0\u884c\u65f6\uff0c\u4ea7\u751f\u201c\u54d2\u54d2\u54d2\u201d\u7684\u70b9\u706b\u3001\u505c\u673a\u58f0\u662f\u6b63\u5e38\u73b0\u8c61\u3002<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u274c <strong>\u8fd9\u662f\u7cfb\u7edf\u914d\u7f6e\u4e25\u91cd\u9519\u8bef\u7684\u5178\u578b\u8868\u73b0<\/strong>\u3002\u5176\u6839\u56e0\u662f\u9505\u7089\u7684\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u5927\u4e8e\u672b\u7aef\u7684\u6700\u5927\u6563\u70ed\u91cf\uff0c\u5bfc\u81f4\u70ed\u91cf\u201c\u62c9\u4e0d\u8d70\u201d\uff0c\u6c34\u6e29\u5feb\u901f\u8fbe\u6807\u540e\u505c\u673a\u3002\u9891\u7e41\u542f\u505c\u4e0d\u4ec5\u5f71\u54cd\u8212\u9002\u5ea6\uff08\u6e29\u5ea6\u6ce2\u52a8\u5927\uff09\uff0c\u66f4\u662f\u80fd\u8017\u98d9\u5347\u7684\u5143\u51f6\uff08\u6bcf\u6b21\u542f\u52a8\u548c\u7089\u819b\u5439\u626b\u90fd\u4f1a\u635f\u5931\u5927\u91cf\u70ed\u91cf\uff09\uff0c\u8fd8\u4f1a\u5927\u5e45\u7f29\u77ed\u9505\u7089\u4f7f\u7528\u5bff\u547d\u3002<\/li>\n\n<li><strong>\u5185\u94fe<\/strong>\uff1a\u5bf9\u6bd4\u4e0d\u540c\u70ed\u6e90\u7684\u5de5\u4f5c\u539f\u7406\uff0c\u8bf7\u89c1 <strong>3.1\u8282 \u9505\u7089\u5de5\u4f5c\u539f\u7406\u4e0e\u75db\u70b9\u5185\u94fe<\/strong>\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u8bef\u533a\u516d\uff1a\u201c\u96f6\u51b7\u6c34\u5c31\u662f\u6700\u597d\u7684\u70ed\u6c34\u65b9\u6848\u201d<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9519\u8bef\u8ba4\u77e5<\/strong>\uff1a\u8ba4\u4e3a\u80fd\u201c\u79d2\u51fa\u70ed\u6c34\u201d\u7684\u201c\u96f6\u51b7\u6c34\u201d\u70ed\u6c34\u5668\u6216\u5faa\u73af\u6cf5\u662f\u6700\u4f73\u70ed\u6c34\u65b9\u6848\u3002<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u5e38\u89c1\u7684\u201c\u96f6\u51b7\u6c34\u201d\u65b9\u6848\uff08\u652f\u7ba1\u5faa\u73af\uff09\u5b58\u5728<strong>\u8fd1\u70eb\u8fdc\u51c9\u3001\u80fd\u8017\u9ad8\u3001\u5065\u5eb7\u9690\u60a3<\/strong>\u4e09\u5927\u95ee\u9898\u3002\u5176\u6839\u56e0\u5728\u4e8e\u5faa\u73af\u70ed\u6c34\u901a\u8fc7\u5899\u4f53\u6563\u5931\u70ed\u91cf\uff0c\u5bfc\u81f4\u71c3\u6c14\u8d39\u98d9\u5347\uff1b\u4e14\u51b7\u70ed\u6c34\u7ba1\u5728\u9f99\u5934\u5904\u6c47\u5408\uff0c\u5bf9\u51c0\u6c34\u5668\u7b49\u654f\u611f\u8bbe\u5907\u6709\u5065\u5eb7\u98ce\u9669\u3002<strong>\u201c\u4e3b\u7ba1\u5faa\u73af+\u5206\u6c34\u5668\u7cfb\u7edf\u201d<\/strong> \u624d\u662f\u771f\u6b63\u7684\u66f4\u4f18\u65b9\u6848\u3002<\/li>\n\n<li><strong>\u5185\u94fe<\/strong>\uff1a\u5982\u4f55\u5b9e\u73b0\u771f\u6b63\u9ad8\u6548\u7684\u70ed\u6c34\u7cfb\u7edf\uff0c\u8bf7\u89c1 <strong>3.2\u8282 \u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u65b9\u6848<\/strong>\u3002<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">2.3 \u5e38\u89c1\u9519\u8bef\u89e3\u51b3\u624b\u6bb5\u4e0e\u98ce\u9669<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5728\u610f\u8bc6\u5230\u7cfb\u7edf\u6709\u95ee\u9898\u540e\uff0c\u4e00\u4e9b\u4e0d\u4e13\u4e1a\u7684\u5546\u5bb6\u6216\u7528\u6237\u4f1a\u91c7\u7528\u9519\u8bef\u7684\u201c\u8865\u6551\u201d\u624b\u6bb5\uff0c\u7ed3\u679c\u5f80\u5f80\u662f\u82b1\u8d39\u66f4\u591a\u3001\u6548\u679c\u66f4\u5dee\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9519\u8bef\u624b\u6bb5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9519\u8bef\u8868\u73b0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6839\u56e0\u5206\u6790<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6b63\u786e\u505a\u6cd5<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u540e\u679c\u4e0e\u98ce\u9669<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u76f2\u76ee\u52a0\u7f13\u51b2\u6c34\u7bb1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3a\u7f13\u89e3\u201c\u9891\u7e41\u542f\u505c\u201d\u52a0\u88c5\u6c34\u7bb1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6df7\u6dc6\u4e86\u201c\u5b9a\u9891\u201d\u548c\u201c\u53d8\u9891\u201d\u7cfb\u7edf\u7684\u9700\u6c42\u3002\u5bf9\u5b9a\u9891\u7cfb\u7edf\uff0c\u6c34\u7bb1\u662f\u5fc5\u9700\u54c1\uff1b\u5bf9\u5168\u53d8\u9891\u7cfb\u7edf\uff0c\u6c34\u7bb1\u662f\u753b\u86c7\u6dfb\u8db3\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u5168\u53d8\u9891\u7cfb\u7edf\uff0c\u5e94\u4f18\u5316\u63a7\u5236\u7cfb\u7edf\u548c\u8054\u52a8\u903b\u8f91\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u589e\u52a0\u7cfb\u7edf\u590d\u6742\u5ea6\u3001\u6545\u969c\u70b9\uff0c\u6d6a\u8d39\u4e86\u53d8\u9891\u7684\u8282\u80fd\u4f18\u52bf\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e0d\u505a\u6c34\u6cf5\u8054\u52a8<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6c34\u6cf524\u5c0f\u65f6\u8fd0\u8f6c\uff0c\u6d41\u91cf\u4e0d\u8db3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8ba4\u4e3a\u53ea\u8981\u6c34\u5728\u6d41\u52a8\u5c31\u662f\u597d\u7684\uff0c\u5ffd\u7565\u4e86\u6c34\u6cf5\u7684\u7535\u8017\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u6cf5\u5fc5\u987b\u4e0e\u672b\u7aef\u9700\u6c42\u8054\u52a8<\/strong>\u3002\u5ba4\u6e29\u8fbe\u6807\uff0c\u6c34\u6cf5\u505c\u6b62\u8fd0\u884c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7528\u6237\u7535\u8d39\u98d9\u5347\uff08\u5e74\u589e\u6570\u767e\u5143\uff09\uff0c\u957f\u671f\u8fd0\u884c\u6210\u672c\u6781\u9ad8\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6df7\u7528\u4e24\u7528\u58c1\u6302\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3a\u4e86\u8282\u7701\u521d\u88c5\u6210\u672c\uff0c\u4e70\u4e00\u53f0\u4e24\u7528\u7089\u89e3\u51b3\u91c7\u6696+\u5168\u90e8\u70ed\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e24\u7528\u7089\u7684\u8bbe\u8ba1\u77db\u76fe\uff1a\u4e3a\u6ee1\u8db3\u751f\u6d3b\u70ed\u6c34\uff08\u598216L\u82b1\u6d12\uff09\u5fc5\u987b\u9009\u5927\u529f\u7387\uff0c\u4f46\u91c7\u6696\u5b63\u529f\u7387\u4e25\u91cd\u8fc7\u5269\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u8bbe\u8ba1<\/strong>\uff1a\u72ec\u7acb\u7684\u70ed\u6c34\u5668+\u5355\u91c7\u6696\u7cfb\u7edf\u7089\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u5b63\u9891\u7e41\u542f\u505c\u3001\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed\uff1b\u590f\u5b63\u70ed\u6c34\u8fc7\u70eb\uff1b\u7cfb\u7edf\u5bff\u547d\u7f29\u77ed\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9009\u7528\u52a3\u8d28\u8f85\u6750<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3a\u4e86\u7701\u94b1\uff0c\u4f7f\u7528\u4e0d\u5e26\u68c0\u6d4b\u62a5\u544a\u7684\u6324\u5851\u677f\u3001\u975e\u5168\u94dd\u53cd\u5c04\u819c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5ffd\u7565\u9690\u853d\u5de5\u7a0b\u4e2d\u8f85\u6750\u7684\u957f\u671f\u6027\u80fd\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u6e29\u677f\u9009\u5e26\u68c0\u6d4b\u62a5\u544a\u7684\u6b63\u89c4\u4ea7\u54c1\uff0c\u53cd\u5c04\u819c\u63a8\u8350\u5168\u94dd\u53cd\u5c04\u819c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u6e29\u6027\u80fd\u8870\u51cf\uff0c\u70ed\u91cf\u6d41\u5931\uff1b\u53cd\u5c04\u819c\u8150\u8680\u5931\u6548\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e0d\u5b89\u88c5\u8054\u52a8\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ea\u4e70\u4e86\u9505\u7089\u548c\u6e29\u63a7\u9600\uff0c\u4f46\u4e24\u8005\u4e0d\u901a\u8baf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8ba4\u4e3a\u624b\u52a8\u5f00\u5173\u9600\u95e8\u5c31\u662f\u63a7\u5236\u4e86\uff0c\u9505\u7089\u4f1a\u81ea\u52a8\u5339\u914d\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5\u8054\u52a8\u63a7\u5236\u6a21\u5757\uff0c\u5b9e\u73b0\u201c\u5ba4\u6e29\u8fbe\u6807\u2192\u9505\u7089\u505c\u673a\u201d\u7684\u903b\u8f91\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u201c\u76f2\u76ee\u70e7\u201d\uff0c\u65e0\u6548\u4ea7\u70ed\uff0c\u80fd\u8017\u9ad8\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/longmai-nt.com\/?page_id=10356\">\u6210\u90fd\u897f\u6d3e\u6f9c\u5cb8\u7cbe\u88c5\u5730\u6696\u62c6\u9664\u91cd\u505a\uff5c\u53cd\u5c04\u819c\u94dd\u819c\u5316\u6e23\u5b9e\u8bc1 - \u9f99\u8109\u6696\u901a<\/a><\/p>\n\n<h3 class=\"wp-block-heading\">2.4 \u7528\u6237\u5e38\u89c1\u62c5\u5fc3\u4e0e\u6b63\u786e\u5e94\u5bf9\u7b56\u7565<\/h3>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u300a\u5ba2\u6237\u6210\u529f\u7b56\u7565\u5361\u4e3b\u5e93\u300b\u53ca\u9500\u552e\u8bdd\u672f\u7ecf\u9a8c\uff0c\u7528\u6237\u5728\u5730\u6696\u51b3\u7b56\u8fc7\u7a0b\u4e2d\uff0c\u666e\u904d\u5b58\u5728\u4ee5\u4e0b\u4e94\u5927\u62c5\u5fc3\u3002\u6b63\u786e\u7684\u5e94\u5bf9\u7b56\u7565\u4e0d\u662f\u5b89\u629a\uff0c\u800c\u662f\u7528\u4e13\u4e1a\u548c\u6570\u636e\u53bb\u5316\u89e3\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7528\u6237\u62c5\u5fc3\uff08\u539f\u8bdd\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u672c\u8d28<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6b63\u786e\u5e94\u5bf9\u7b56\u7565<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53ef\u5f15\u7528\u6570\u636e\/\u5de5\u5177<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u201c\u6015\u8d39\u7535\/\u8d39\u6c14\u201d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62c5\u5fc3\u957f\u671f\u8fd0\u884c\u8d39\u7528\u8fc7\u9ad8\uff0c\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u7ed9\u51fa<strong>\u5e74\u8fd0\u884c\u8d39\u7528\u4f30\u7b97<\/strong>\uff08\u6839\u636e\u6237\u578b\u3001\u4f7f\u7528\u4e60\u60ef\uff09\u3002<br>2. \u5f15\u7528\u516c\u5f00\u6570\u636e\uff08\u5982\u7a7a\u6c14\u80fdCOP\u22653.5\uff0c\u6bd4\u71c3\u6c14\u770140%-60%\uff09\u3002<br>3. \u63d0\u4f9b<strong>20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\u6848\u4f8b<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\u8868\u300b\uff08\u6307\u4ee42.2\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u201c\u6015\u574f\u4e86\u4e0d\u597d\u4fee\u201d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62c5\u5fc3\u5730\u6696\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u4e00\u65e6\u635f\u574f\u7ef4\u4fee\u6210\u672c\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u5f3a\u8c03<strong>\u7cbe\u5de5\u7cbe\u5320\u65bd\u5de5\u6807\u51c6<\/strong>\uff08\u6253\u538b\u9a8c\u6536\u3001\u5f71\u50cf\u7559\u5b58\uff09\u3002<br>2. \u63d0\u4f9b<strong>\u54c1\u724c\u8d28\u4fdd<\/strong>\uff08\u5982\u4f1f\u661f50\u5e74\u8d28\u4fdd\u3001\u4e3b\u673a10\u5e74\uff09\u3002<br>3. \u5f3a\u8c03<strong>\u963b\u6c27\u7ba1<\/strong>\u548c<strong>\u9632\u8150\u4fdd\u62a4\u5242<\/strong>\u7684\u4f5c\u7528\uff0c\u4ece\u6e90\u5934\u51cf\u5c11\u6545\u969c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d28\u4fdd\u6587\u4ef6\u3001\u65bd\u5de5\u9a8c\u6536\u5355<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u201c\u6015\u6f0f\u6c34\u201d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62c5\u5fc3\u5730\u6696\u7ba1\u7834\u88c2\u5bfc\u81f4\u6ce1\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u89e3\u91ca<strong>\u76d8\u7ba1\u662f\u4e00\u6574\u6839\u7ba1<\/strong>\uff0c\u4e2d\u95f4\u65e0\u63a5\u5934\uff0c\u8fd9\u662f\u6700\u5b89\u5168\u7684\u3002<br>2. \u5f3a\u8c03<strong>\u963b\u6c27\u7ba1<\/strong>\u6297\u8150\u8680\u4f18\u52bf\u3002<br>3. \u8bf4\u660e<strong>\u6253\u538b\u9a8c\u6536\u6807\u51c6<\/strong>\uff08\u4fdd\u538b0.6-0.8MPa\uff0c24\u5c0f\u65f6\u4e0d\u6389\u538b\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a12K404\u5730\u9762\u8f90\u5c04\u4f9b\u6696\u7cfb\u7edf\u65bd\u5de5\u5b89\u88c5\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u201c\u6015\u4e0d\u70ed\u201d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62c5\u5fc3\u6548\u679c\u8fbe\u4e0d\u5230\u9884\u671f\uff0c\u94b1\u767d\u82b1\u4e86<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u5c55\u793a<strong>\u70ed\u8d1f\u8377\u8ba1\u7b97<\/strong>\u8fc7\u7a0b\uff0c\u5f15\u7528<strong>\u56fd\u6807GB50736<\/strong>\u3002<br>2. \u63d0\u4f9b\u540c\u6237\u578b\u5ba2\u6237\u7684<strong>\u5b9e\u6d4b\u6570\u636e<\/strong>\uff08\u5982\u5ba4\u6e2920\u2103\uff0c\u67d0\u5e73\u7c73\u8017\u6c14\u91cf\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u91c7\u6696\u6570\u636e\u6c47\u603b\u300b\u3001\u5ba2\u6237\u6848\u4f8b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u201c\u6015\u88ab\u5751\/\u4e70\u8d35\u4e86\u201d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62c5\u5fc3\u4ef7\u683c\u4e0d\u900f\u660e\uff0c\u82b1\u4e86\u51a4\u6789\u94b1<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u63d0\u4f9b<strong>\u900f\u660e\u62a5\u4ef7\u4e66<\/strong>\uff0c\u660e\u786e\u62c6\u5206\u8bbe\u5907\/\u5b89\u88c5\/\u8f85\u6750\u4ef7\u683c\u3002<br>2. \u7ed9\u51fa <strong>\u201c20\u5e74\u603b\u8d26\u201d<\/strong> \u800c\u975e\u5355\u6b21\u62a5\u4ef7\uff0c\u8ba9\u5ba2\u6237\u770b\u5230\u957f\u671f\u4ef7\u503c\u548c\u6295\u5165\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u900f\u660e\u62a5\u4ef7\u6a21\u677f\u300b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e09\u7ae0\uff1a\u70ed\u6e90\u2014\u2014\u7cfb\u7edf\u7684\u201c\u5fc3\u810f\u201d<\/h2>\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u628a\u5730\u6696\u7cfb\u7edf\u6bd4\u4f5c\u4e00\u4e2a\u4eba\uff0c\u70ed\u6e90\u5c31\u662f\u201c\u5fc3\u810f\u201d\uff0c\u8d1f\u8d23\u4e3a\u6574\u4e2a\u7cfb\u7edf\u63d0\u4f9b\u6e90\u6e90\u4e0d\u65ad\u7684\u70ed\u91cf\u3002\u9009\u5bf9\u70ed\u6e90\uff0c\u7cfb\u7edf\u5c31\u6210\u529f\u4e86\u4e00\u534a\uff1b\u9009\u9519\u4e86\uff0c\u540e\u7eed\u6240\u6709\u52aa\u529b\u90fd\u53ef\u80fd\u4e8b\u500d\u529f\u534a\u3002\u672c\u7ae0\u5c06\u5e26\u60a8\u4ece\u5934\u7406\u89e3\u70ed\u6e90\u7684\u8fd0\u884c\u903b\u8f91\u3001\u4e0d\u540c\u70ed\u6e90\u7684\u6838\u5fc3\u5dee\u5f02\uff0c\u4ee5\u53ca\u5982\u4f55\u907f\u5f00\u5e38\u89c1\u7684\u201c\u9009\u578b\u9677\u9631\u201d\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">3.1 \u9505\u7089\u5de5\u4f5c\u539f\u7406\u4e0e\u75db\u70b9\u5185\u94fe<\/h3>\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading has-icon has-icon-right\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u666e\u901a\u5e38\u89c4\u4e24\u7528\u58c1\u6302\u7089\u8fd0\u884c\u539f\u7406\u2014\u2014\u52a8\u753b\u6f14\u793a<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n<div aria-labelledby=\"accordion-item-2\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<iframe src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-bgl-bigualu-bigualuyunxingyuanli.html\" \n  style=\"width:100%; height:2200px; border:none;\" scrolling=\"yes\">\n<\/iframe>\n<\/div>\n<\/div>\n<\/div>\n\n<h4 class=\"wp-block-heading\">\u57fa\u672c\u903b\u8f91\uff1a\u6c34\u6e29\u63a7\u5236\uff0c\u800c\u975e\u5ba4\u6e29\u63a7\u5236<\/h4>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u7406\u89e3\u6574\u4e2a\u5730\u6696\u7cfb\u7edf\u6700\u6838\u5fc3\u3001\u4e5f\u6700\u5bb9\u6613\u88ab\u8bef\u89e3\u7684\u903b\u8f91\u3002<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u58c1\u6302\u7089\u662f\u6c34\u6e29\u63a7\u5236\u8bbe\u5907\uff0c\u800c\u975e\u5ba4\u6e29\u63a7\u5236\u8bbe\u5907\u3002<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">\u5b83\u7684\u5de5\u4f5c\u65b9\u5f0f\u5982\u4e0b\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u8bbe\u5b9a\u76ee\u6807\u6c34\u6e29<\/strong>\uff08\u598260\u2103\uff09\u3002<\/li>\n\n<li><strong>\u5faa\u73af\u6cf5\u542f\u52a8<\/strong>\uff0c\u63a8\u52a8\u7cfb\u7edf\u5185\u7684\u6c34\u5f00\u59cb\u6d41\u52a8\u3002<\/li>\n\n<li><strong>\u70b9\u706b\u71c3\u70e7\u52a0\u70ed<\/strong>\uff0c\u5c06\u6c34\u52a0\u70ed\u81f3\u8bbe\u5b9a\u6e29\u5ea6\u3002<\/li>\n\n<li><strong>\u68c0\u6d4b\u6c34\u6e29<\/strong>\uff1a\u6301\u7eed\u68c0\u6d4b\u51fa\u6c34\u6216\u56de\u6c34\u6e29\u5ea6\u3002<\/li>\n\n<li><strong>\u89e6\u53d1\u52a8\u4f5c<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5f53\u5b9e\u9645\u6c34\u6e29<strong>\u4f4e\u4e8e<\/strong>\u8bbe\u5b9a\u503c\u65f6 \u2192 \u71c3\u70e7\u5668<strong>\u70b9\u706b\u5de5\u4f5c<\/strong>\u3002<\/li>\n\n<li>\u5f53\u5b9e\u9645\u6c34\u6e29<strong>\u8fbe\u5230<\/strong>\u8bbe\u5b9a\u503c\u65f6 \u2192 \u71c3\u70e7\u5668<strong>\u505c\u673a\u7184\u706b<\/strong>\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u540e\u5439\u626b<\/strong>\uff1a\u5173\u673a\u540e\u98ce\u673a\u7ee7\u7eed\u8fd0\u884c\u4e00\u6bb5\u65f6\u95f4\uff0c\u6392\u51fa\u6b8b\u4f59\u5e9f\u6c14\uff0c\u540c\u65f6\u5438\u5165\u51b7\u7a7a\u6c14\u3002<\/li>\n\n<li><strong>\u5faa\u73af\u5f80\u590d<\/strong>\uff1a\u5438\u5165\u51b7\u7a7a\u6c14 \u2192 \u6c34\u6e29\u4e0b\u964d \u2192 \u518d\u6b21\u89e6\u53d1\u70b9\u706b\u3002<\/li>\n<\/ol>\n\n<h4 class=\"wp-block-heading\">\u6838\u5fc3\u75db\u70b9\u5185\u94fe\uff1a\u4ece<a href=\"https:\/\/longmai-nt.com\/?page_id=3872\">\u58c1\u6302\u7089\u5de5\u4f5c\u539f\u7406<\/a>\u5230\u5b9e\u9645\u95ee\u9898<\/h4>\n\n<p class=\"wp-block-paragraph\">\u9505\u7089\u8fd9\u4e00\u201c\u53ea\u770b\u6c34\u6e29\u3001\u4e0d\u770b\u5ba4\u6e29\u201d\u7684\u57fa\u672c\u903b\u8f91\uff0c\u662f\u5f15\u53d1\u540e\u7eed\u4e00\u7cfb\u5217\u95ee\u9898\u7684\u7269\u7406\u6839\u6e90\u3002\u4ee5\u4e0b\u662f\u901a\u8fc7\u5185\u94fe\uff0c\u5c06\u5de5\u4f5c\u539f\u7406\u4e0e\u7b2c\u4e8c\u7ae0\u8282\u4e2d\u7684\u5e38\u89c1\u75db\u70b9\u8fdb\u884c\u5173\u8054\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u75db\u70b9\u73b0\u8c61<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7269\u7406\u539f\u7406\uff08\u5de5\u4f5c\u539f\u7406\u5bfc\u81f4\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u94fe\u81f3\u7ae0\u8282\uff08\u5feb\u901f\u5b9a\u4f4d\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9891\u7e41\u542f\u505c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff088-10kW\uff09\u8fdc\u8d85\u672b\u7aef\u5b9e\u9645\u6563\u70ed\u91cf\uff08\u5982\u5c0f\u6237\u578b\/\u5f001-2\u7ec4\u6696\u6c14\u7247\u4ec53-5kW\uff09\u2192 \u6c34\u6e29\u5feb\u901f\u8fbe\u6807 \u2192 \u505c\u673a \u2192 \u540e\u5439\u626b\u5438\u5165\u51b7\u7a7a\u6c14 \u2192 \u6c34\u6e29\u9aa4\u964d \u2192 \u518d\u6b21\u70b9\u706b \u2192 \u6076\u6027\u5faa\u73af\u3002<strong>\u71c3\u6c14\u6d6a\u8d3920-30%<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[2.2\u8282 - \u8bef\u533a\u4e00]<\/strong> \u201c\u9505\u7089\u529f\u7387\u8d8a\u5927\u8d8a\u597d\u201d<br><strong>[2.2\u8282 - \u8bef\u533a\u4e94]<\/strong> \u201c\u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u662f\u6b63\u5e38\u7684\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e0\u6548\u4ea7\u70ed<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5ba4\u6e29\u5df2\u8fbe\u6807\uff08\u598220\u2103\uff09\uff0c\u4f46\u9505\u7089\u4ecd\u5728\u6309\u6c34\u6e29\u6307\u4ee4\u5de5\u4f5c\u3002\u56e0\u4e3a\u6c34\u6e29\u672a\u5230\u8bbe\u5b9a\u503c\uff08\u598260\u2103\uff09\uff0c\u9505\u7089\u4f1a\u201c\u50bb\u50bb\u5730\u201d\u7ee7\u7eed\u71c3\u70e7\u3002<strong>\u4eba\u8d70\u4e86\uff0c\u5c4b\u5b50\u70ed\u4e86\uff0c\u5b83\u8fd8\u4e00\u76f4\u5728\u70e7<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[2.2\u8282 - \u8bef\u533a]<\/strong> \u201c\u6052\u6e29\u9600\u5173\u95ed\u4e86\uff0c\u9505\u7089\u5c31\u4e0d\u4f1a\u518d\u542f\u52a8\u4e86\u201d<br><strong>[4.3.1\u8282]<\/strong> \u201c\u6c34\u6e29\u63a7\u5236 vs \u5ba4\u6e29\u63a7\u5236\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u80fd\u8017\u98d9\u5347<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9891\u7e41\u542f\u505c + \u65e0\u6548\u4ea7\u70ed + \u540e\u5439\u626b\u70ed\u91cf\u635f\u5931 \u2192 \u7efc\u5408\u70ed\u6548\u7387\u5927\u5e45\u964d\u4f4e\uff0c\u71c3\u6c14\u8d39\u81ea\u7136\u5c45\u9ad8\u4e0d\u4e0b\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[2.3\u8282 - \u9519\u8bef\u624b\u6bb5]<\/strong> \u201c\u4e0d\u505a\u6c34\u6cf5\u8054\u52a8\u201d<br><strong>[2.4\u8282 - \u62c5\u5fc3]<\/strong> \u201c\u6015\u8d39\u7535\/\u8d39\u6c14\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6e29\u5ea6\u6ce2\u52a8\u5927<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u9891\u7e41\u542f\u505c \u2192 \u51fa\u6c34\/\u56de\u6c34\u6e29\u5ea6\u5267\u70c8\u6ce2\u52a8 \u2192 \u5730\u6696\u8868\u9762\u6e29\u5ea6\u4e0d\u7a33\u5b9a \u2192 \u4f53\u611f\u6e29\u5dee\u660e\u663e\uff0c\u4e0d\u8212\u9002\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[2.2\u8282 - \u8bef\u533a\u4e94]<\/strong> \u201c\u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u662f\u6b63\u5e38\u7684\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7cfb\u7edf\u5bff\u547d\u7f29\u77ed<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9891\u7e41\u70b9\u706b\/\u7184\u706b \u2192 \u70ed\u4ea4\u6362\u5143\u4ef6\u53cd\u590d\u70ed\u80c0\u51b7\u7f29 \u2192 \u710a\u70b9\u75b2\u52b3 \u2192 \u6f0f\u6c34\u98ce\u9669\u589e\u52a0\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\uff08\u95f4\u63a5\u5173\u80542.3\u8282\u9519\u8bef\u624b\u6bb5\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u603b\u7ed3<\/strong>\uff1a\u9505\u7089\u7684\u95ee\u9898\u4e0d\u662f\u5b83\u4e0d\u597d\uff0c\u800c\u662f <strong>\u201c\u6ca1\u4eba\u544a\u8bc9\u5b83\u5ba4\u6e29\u5df2\u7ecf\u591f\u4e86\u201d<\/strong>\u3002\u8054\u52a8\u63a7\u5236\u5c31\u662f\u89e3\u51b3\u8fd9\u4e00\u6838\u5fc3\u77db\u76fe\u7684\u5173\u952e\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">3.2 \u4e24\u7528\u58c1\u6302\u7089\u7684\u6839\u672c\u77db\u76fe<\/h3>\n\n<p class=\"wp-block-paragraph\">\u4e24\u7528\u58c1\u6302\u7089\uff08\u4e5f\u79f0\u201c\u53cc\u529f\u80fd\u7089\u201d\uff09\u662f\u76ee\u524d\u5bb6\u88c5\u5e02\u573a\u6700\u5e38\u89c1\u7684\u4ea7\u54c1\uff0c\u5b83\u65e2\u662f\u91c7\u6696\u70ed\u6e90\uff0c\u53c8\u662f\u751f\u6d3b\u70ed\u6c34\u70ed\u6e90\u3002\u4f46\u8fd9\u4e2a\u201c\u4e8c\u5408\u4e00\u201d\u7684\u8bbe\u8ba1\uff0c\u6070\u6070\u662f\u5b83\u6700\u5927\u7684\u75db\u70b9\u6765\u6e90\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u9700\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u751f\u6d3b\u70ed\u6c34\u9700\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u77db\u76fe\u7ed3\u679c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6240\u9700\u529f\u7387<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5c0f\u800c\u7a33<\/strong>\u3002100\u33a1\u6237\u578b\uff0c\u65e5\u5e38\u6052\u6e29\u4ec5\u97005-7kW\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5927\u800c\u6025<\/strong>\u3002\u4e00\u4e2a\u6dcb\u6d74\u55b7\u5934\uff086-8L\/min\uff09\u5c31\u9700\u898115-20kW\uff1b\u540c\u65f6\u6d17\u6fa1+\u6d17\u7897\u9700\u898130kW+\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3a\u4e86\u6ee1\u8db3\u5076\u5c14\u7684\u70ed\u6c34\u5cf0\u503c\u9700\u6c42\uff0c\u7528\u6237\u88ab\u8feb\u9009\u62e9\u5927\u529f\u7387\uff0824kW\u300128kW\u300135kW\uff09\u7684\u7089\u5b50\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5de5\u4f5c\u72b6\u6001<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u8fd0\u884c\uff0c\u9700\u8981\u4f4e\u529f\u7387\u7a33\u5b9a\u8f93\u51fa\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u77ed\u671f\u51b2\u51fb\uff0c\u9700\u8981\u77ac\u65f6\u5927\u529f\u7387\u8f93\u51fa\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u529f\u7387\u7089\u5b50\u5728\u91c7\u6696\u5b63\u957f\u671f\u5904\u4e8e\u201c\u5c0f\u8d1f\u8377\u201d\u72b6\u6001\uff0c\u9a71\u52a8\u529f\u7387\u8fdc\u8d85\u9700\u6c42\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u540e\u679c<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u91c7\u6696\u5b63\uff08\u51ac\u5b63\uff09<\/strong>\uff1a\u529f\u7387\u4e25\u91cd\u8fc7\u5269\uff0c\u9891\u7e41\u542f\u505c\uff0c\u80fd\u8017\u9ad8\u3002<\/li>\n\n<li><strong>\u975e\u91c7\u6696\u5b63\uff08\u590f\u5b63\uff09<\/strong>\uff1a\u6700\u5c0f\u529f\u7387\uff08\u7ea610kW\uff09\u8fdc\u9ad8\u4e8e\u6d17\u6fa1\u6240\u9700\uff08\u7ea63-5kW\uff09\uff0c\u70ed\u6c34\u6c34\u6e29\u8fc7\u9ad8\uff0c\u9700\u8981\u6df7\u6c34\u9600\uff0c\u82e5\u5904\u7406\u4e0d\u5f53\u751a\u81f3\u4f1a\u51fa\u73b0\u201c\u590f\u5929\u70ed\u6c34\u70eb\u6b7b\u4eba\u201d\u7684\u56f0\u5883\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">3.2.0 \u7cfb\u7edf\u5316\u601d\u7ef4\uff1a\u70ed\u6e90\u9009\u578b\u7684\u94c1\u4e09\u89d2<\/h4>\n\n<p class=\"wp-block-paragraph\">\u5730\u6696\u70ed\u6e90\u9009\u578b\u4e0d\u662f\"\u4e70\u4e00\u53f0\u9505\u7089\"\u90a3\u4e48\u7b80\u5355\uff0c\u800c\u662f\u4e09\u6761\u7ebf\u7684\u7cbe\u786e\u4ea4\u6c47\uff1a<\/p>\n\n<pre class=\"wp-block-code\"><code>\u672b\u7aef\u70ed\u9700\u6c42\uff08kW\uff09\u2192 \u70ed\u6e90\u529f\u7387\u9009\u578b \u2192 \u71c3\u6c14\u8868\/\u7535\u8868\u6821\u6838 \u2192 \u5faa\u73af\u6cf5+\u7ba1\u8def\u5339\u914d<\/code><\/pre>\n\n<p class=\"wp-block-paragraph\">\u9009\u5927\u4e86\uff08\u5927\u9a6c\u62c9\u5c0f\u8f66\uff09\uff1a\u9891\u7e41\u542f\u505c\uff0c\u8bbe\u5907\u5bff\u547d\u7f29\u77ed\uff0c\u4f4e\u8d1f\u8377\u6548\u7387\u66b4\u8dcc\u3002<br>\u9009\u5c0f\u4e86\uff08\u5c0f\u9a6c\u62d6\u5927\u8f66\uff09\uff1a\u5929\u51b7\u65f6\u6e29\u5ea6\u4e0a\u4e0d\u53bb\uff0c\u7cfb\u7edf\u957f\u671f\u8fc7\u8f7d\u8fd0\u884c\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">3.2.1 \u7ec8\u6781\u65b9\u6848\uff1a\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u8bbe\u8ba1<\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ea2\u7ebf<\/strong>\uff1a\u6839\u636e\u300a\u9f99\u8109\u6696\u901a\u300b\u8bbe\u8ba1\u89c4\u8303\uff0c<strong>\u5f53\u91c7\u6696\u9762\u79ef\u2264150\u33a1\u65f6\uff0c\u4e25\u7981\u4e3a\u6ee1\u8db3\u70ed\u6c34\u9700\u6c42\u800c\u9009\u7528\u226528kW\u7684\u4e24\u7528\u7089<\/strong>\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u4ee5\u4e0b\u662f\u6765\u81ea\u77e5\u8bc6\u5e93\u7684\u5b8c\u6574\u6848\u4f8b\uff0c\u6e05\u6670\u5c55\u793a\u4e86\u6b63\u786e\u4e0e\u9519\u8bef\u505a\u6cd5\uff1a<\/strong><\/p>\n\n<h4 class=\"wp-block-heading\">\u5e38\u89c1\u9519\u8bef\u793a\u4f8b<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u80cc\u666f<\/strong>\uff1a\u5218\u5148\u751f\uff0c\u5bb6\u88c5150\u33a1\uff0c\u67092\u4e2a\u536b\u751f\u95f4\uff0c\u5e38\u4f4f5\u53e3\u4eba\u3002\u91c7\u6696\u70ed\u8d1f\u837722kW\uff0c\u751f\u6d3b\u70ed\u6c34\u9700\u6c42\u5927\u3002<\/li>\n\n<li><strong>\u9519\u8bef\u65b9\u5f0f<\/strong>\uff1a\u8003\u8651\u5230\u9700\u8981\u540c\u65f6\u4f9b\u6696\u548c\u6d17\u6fa1\uff0c\u9009\u4e86\u4e00\u53f0<strong>35kW\u7684\u4e24\u7528\u58c1\u6302\u7089<\/strong>\u3002<\/li>\n\n<li><strong>\u540e\u679c<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u91c7\u6696\u5b63\uff08\u51ac\u5b63\uff09<\/strong>\uff1a35kW\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u7ea612kW\uff0c\u8fdc\u5927\u4e8e\u5730\u6696\u5b9e\u9645\u9700\u6c42\uff08\u7ea65-7kW\uff09\uff0c\u5bfc\u81f4\u9505\u7089\u9891\u7e41\u542f\u505c\uff0c\u71c3\u6c14\u8d39\u98d9\u5347\u3002<\/li>\n\n<li><strong>\u975e\u91c7\u6696\u5b63\uff08\u590f\u5b63\uff09<\/strong>\uff1a35kW\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff08\u7ea610kW\uff09\u8fdc\u9ad8\u4e8e\u6d17\u6fa1\u6240\u9700\uff08\u7ea63-5kW\uff09\uff0c\u70ed\u6c34\u6c34\u6e29\u8fc7\u9ad8\uff0c\u9700\u8981\u6df7\u6c34\u9600\uff0c\u751a\u81f3\u51fa\u73b0\u201c\u590f\u5929\u70ed\u6c34\u70eb\u6b7b\u4eba\u201d\u7684\u56f0\u5883\u3002<\/li>\n\n<li><strong>\u7ed3\u8bba<\/strong>\uff1a\u4e00\u53f035kW\u7089\u5b50\uff0c\u65e2\u4e0d\u8282\u80fd\uff0c\u4e5f\u4e0d\u8212\u9002\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">\u6b63\u786e\u793a\u4f8b<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u80cc\u666f<\/strong>\uff1a\u540c\u6837\u7684\u60c5\u51b5\uff0c\u5218\u5148\u751f\u3002<\/li>\n\n<li><strong>\u6b63\u786e\u65b9\u5f0f<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u91c7\u6696\u7cfb\u7edf<\/strong>\uff1a\u9009\u8d2d\u4e00\u53f0 <strong><a href=\"https:\/\/longmai-nt.com\/?page_id=4499\">18kW\u7684\u7cfb\u7edf\u7089\uff08\u5355\u91c7\u6696\u7089\uff09<\/a><\/strong>\uff0c\u4ec5\u8d1f\u8d23\u5730\u6696\u3002<\/li>\n\n<li><strong>\u70ed\u6c34\u7cfb\u7edf<\/strong>\uff1a\u5728\u53a8\u623f\u6216\u9633\u53f0\u5b89\u88c5\u4e00\u53f0<strong>13L\u7684\u72ec\u7acb\u71c3\u6c14\u70ed\u6c34\u5668<\/strong>\uff08\u6216\u5bb9\u79ef\u5f0f\u70ed\u6c34\u5668\uff09\uff0c\u4e13\u95e8\u4f9b\u5e94\u5404\u4e2a\u536b\u751f\u95f4\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u7ed3\u679c<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u91c7\u6696\u5b63<\/strong>\uff1a18kW\u7089\u5b50\u4e0e\u5730\u6696\u8d1f\u8377\u5339\u914d\uff0c\u8fd0\u884c\u5e73\u7a33\uff0c\u8282\u80fd\u663e\u8457\u3002<\/li>\n\n<li><strong>\u70ed\u6c34<\/strong>\uff1a\u72ec\u7acb\u70ed\u6c34\u5668\uff0c\u6052\u6e29\u8212\u9002\uff0c\u4e0d\u53d7\u91c7\u6696\u5e72\u6270\uff0c\u590f\u5929\u4e5f\u80fd\u7a33\u5b9a\u5de5\u4f5c\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u7ed3\u8bba<\/strong>\uff1a<strong>\u201c\u7cfb\u7edf\u7089 + \u72ec\u7acb\u70ed\u6c34\u5668\u201d<\/strong> \u5f7b\u5e95\u89e3\u51b3\u4e86\u201c\u5927\u9a6c\u62c9\u5c0f\u8f66\u201d\u548c\u201c\u590f\u5929\u8fc7\u70eb\u201d\u7684\u4e24\u5927\u6838\u5fc3\u75db\u70b9\uff0c\u662f\u6700\u4e13\u4e1a\u3001\u6700\u7701\u5fc3\u7684\u65b9\u6848\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">3.2.3 <strong>\u5e38\u89c4\u7089\u7684\u4f18\u5316\u8def\u5f84<\/strong><\/h4>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\">\u82e5\u9884\u7b97\u6709\u9650\u9009\u5e38\u89c4\u7089\uff0c\u53ef\u901a\u8fc7\u7cfb\u7edf\u4f18\u5316\u63a5\u8fd1\u51b7\u51dd\u7089\u8282\u80fd\u6548\u679c\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u4f18\u5316\u9879<\/th><th>\u505a\u6cd5<\/th><th>\u6548\u679c<\/th><\/tr><\/thead><tbody><tr><td>\u6c34\u529b\u5e73\u8861<\/td><td>\u6bcf\u4e2a\u5206\u96c6\u6c34\u5668\u652f\u8def\u52a0\u88c5\u5e73\u8861\u9600\uff0c\u4fdd\u8bc1\u5404\u56de\u8def\u6d41\u91cf\u5747\u5300<\/td><td>\u907f\u514d\u5c40\u90e8\u8fc7\u70ed\u3001\u5c40\u90e8\u4e0d\u70ed<\/td><\/tr><tr><td>\u8054\u52a8\u63a7\u5236<\/td><td>\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u8054\u52a8\uff1a\u4efb\u4e00\u623f\u95f4\u8fbe\u6807\u2192\u9505\u7089\u964d\u529f\u7387\uff0c\u5168\u5c4b\u8fbe\u6807\u2192\u9505\u7089\u505c\u673a<\/td><td>\u6d88\u9664\"\u76f2\u76ee\u70e7\"\uff0c\u8282\u80fd20-30%<\/td><\/tr><tr><td>\u4f4e\u6e29\u4f9b\u6c34<\/td><td>\u5730\u6696\u4f9b\u6c34\u6e29\u5ea6\u8bbe\u5b9a40-45\u2103\uff08\u914d\u5408\u6df7\u6c34\u4e2d\u5fc3\uff09<\/td><td>\u63d0\u9ad8\u7cfb\u7edfCOP<\/td><\/tr><tr><td>\u6c14\u5019\u8865\u507f<\/td><td>\u5ba4\u5916\u6e29\u5ea6\u4f20\u611f\u5668+\u63a7\u5236\u5668\uff0c\u6839\u636e\u5ba4\u5916\u6e29\u5ea6\u81ea\u52a8\u8c03\u8282\u4f9b\u6c34\u6e29\u5ea6<\/td><td>\u907f\u514d\"\u5929\u6696\u4e86\u8fd8\u5728\u731b\u70e7\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">3.3 \u5e38\u89c4\u7089 vs \u51b7\u51dd\u7089<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5728\u71c3\u6c14\u58c1\u6302\u7089\u5185\u90e8\uff0c\u6839\u636e\u5176\u71c3\u70e7\u548c\u70ed\u4ea4\u6362\u6280\u672f\uff0c\u5206\u4e3a\u5e38\u89c4\u7089\u548c\u51b7\u51dd\u7089\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5e38\u89c4\u7089\uff08\u5b9a\u9891\uff09<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089\uff08\u53d8\u9891\uff09<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5173\u952e\u5dee\u5f02\u70b9<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong><a href=\"https:\/\/longmai-nt.com\/?page_id=3872\">\u5de5\u4f5c\u539f\u7406<\/a><\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c06\u70df\u6c14\u76f4\u63a5\u6392\u51fa\u5ba4\u5916\uff0c\u6392\u70df\u6e29\u5ea6\u9ad8\uff08180-200\u2103\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5229\u7528\u70df\u6c14\u4e2d\u7684\u6c34\u84b8\u6c14\u51b7\u51dd\u91ca\u653e\u6f5c\u70ed\uff0c\u6392\u70df\u6e29\u5ea6\u4f4e\uff0840-60\u2103\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089\u591a\u4e86\u4e00\u4e2a\u201c\u70ed\u91cf\u56de\u6536\u201d\u8fc7\u7a0b<\/strong>\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u6548\u7387<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u6e29\u5de5\u51b5\uff08&gt;70\u2103\uff09\u53ef\u8fbe90%\u5de6\u53f3\uff1b\u4f4e\u6e29\u5de5\u51b5\uff08&lt;60\u2103\uff09\u6548\u7387\u6025\u5267\u4e0b\u964d\u81f350-60%\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6e29\u5de5\u51b5\uff08&lt;55\u2103\uff09\u6548\u7387\u53ef\u8fbe103-108%\uff1b\u9ad8\u6e29\u5de5\u51b5\u6548\u7387\u4e0e\u5e38\u89c4\u7089\u65e0\u5f02\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u7684\u4f18\u52bf\u5fc5\u987b\u5efa\u7acb\u5728<strong>\u4f4e\u6e29\u7cfb\u7edf<\/strong>\u57fa\u7840\u4e4b\u4e0a\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u3002\u5e38\u89c18-10kW\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u3002\u4f18\u8d28\u51b7\u51dd\u7089\u53ef\u4f4e\u81f33-4kW\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089\u80fd\u66f4\u597d\u5730\u5339\u914d\u5c0f\u8d1f\u8377\u9700\u6c42\uff0c\u907f\u514d\u9891\u7e41\u542f\u505c\u3002<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u71c3\u70e7\u8c03\u8282<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u9891\uff0c\u53ea\u80fd\u5355\u4e00\u529f\u7387\u542f\u505c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53d8\u9891\uff0c\u53ef\u65e0\u7ea7\u8c03\u8282\uff08\u59821:10\u6bd4\u4f8b\uff09<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u7089\u80fd\u7cbe\u7ec6\u5316\u5339\u914d\u8d1f\u8377\u53d8\u5316\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7cfb\u7edf\u6210\u672c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u672c\u8eab\u4ef7\u683c\u8f83\u4f4e\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u4ef7\u683c\u9ad8\u7ea630-50%\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u7ed3\u5408\u7cfb\u7edf\u8bbe\u8ba1\u8bc4\u4f30\u603b\u6295\u5165\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9002\u7528\u573a\u666f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u521d\u88c5\u6210\u672c\u654f\u611f\uff1b\u5df2\u6709\u9ad8\u6e29\u7cfb\u7edf\u7684\u7528\u6237\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u914d\u5408\u4f4e\u6e29\u5730\u6696\u7cfb\u7edf\uff0c\u8ffd\u6c42\u957f\u671f\u8282\u80fd\u548c\u7a33\u5b9a\u6027\u7684\u7528\u6237\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089\u5fc5\u987b\u914d\u4f4e\u6e29\u7cfb\u7edf\uff0c\u5426\u5219\u201c\u767d\u4e70\u4e86\u201d\u3002<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5e38\u89c4\u7089<\/strong>\uff1a\u50cf\u5b9a\u9891\u7a7a\u8c03\uff0c\u6280\u672f\u6210\u719f\uff0c\u6210\u672c\u4f4e\uff0c\u4f46\u5b58\u5728\u9891\u7e41\u542f\u505c\u548c\u4f4e\u6e29\u6548\u7387\u4f4e\u7684\u56fa\u6709\u95ee\u9898\u3002<\/li>\n\n<li><strong>\u51b7\u51dd\u7089<\/strong>\uff1a\u50cf\u53d8\u9891\u7a7a\u8c03\uff0c\u6280\u672f\u5148\u8fdb\uff0c\u6548\u7387\u9ad8\uff0c\u80fd\u7cbe\u786e\u5339\u914d\u8d1f\u8377\uff0c\u4f46<strong>\u5fc5\u987b\u914d\u5408\u4f4e\u6e29\u7cfb\u7edf\uff08\u4f9b\u6c34\u6e29\u5ea6\u226455\u2103\uff09<\/strong>\u3002\u5982\u679c\u5bb6\u91cc\u505a\u7684\u662f\u4f20\u7edf\u9ad8\u6e29\u6696\u6c14\u7247\uff0870-80\u2103\uff09\uff0c\u51b7\u51dd\u7089\u7684\u8282\u80fd\u4f18\u52bf\u5c06\u8361\u7136\u65e0\u5b58\u3002<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">3.4 \u7a7a\u6c14\u80fd\u70ed\u6cf5\u7cfb\u7edf<\/h3>\n\n<p class=\"wp-block-paragraph\">\u7a7a\u6c14\u80fd\u70ed\u6cf5\u4ee3\u8868\u4e86\u66f4\u4f4e\u78b3\u8282\u80fd\u7684\u672a\u6765\u8d8b\u52bf\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">\u6280\u672f\u539f\u7406<\/h4>\n\n<p class=\"wp-block-paragraph\">\u7a7a\u6c14\u80fd\u70ed\u6cf5 = \u201c\u53cd\u5411\u8fd0\u884c\u7684\u7a7a\u8c03\u201d\u3002\u5b83\u6d88\u80171\u4efd\u7535\u80fd\uff0c\u9a71\u52a8\u538b\u7f29\u673a\u5de5\u4f5c\uff0c\u4ece\u5ba4\u5916\u7a7a\u6c14\u4e2d\u5438\u65362-3\u4efd\u4f4e\u54c1\u4f4d\u70ed\u80fd\uff0c\u4e00\u8d77\u642c\u8fd0\u81f3\u5ba4\u5185\u6c34\u4e2d\uff0c\u4ea7\u751f3-4\u4efd\u70ed\u91cf\uff08COP=3-4\uff09\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u7ec4\u4ef6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u84b8\u53d1\u5668<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u538b\u7f29\u673a<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u51b7\u51dd\u5668\uff08\u6c1f\u6c34\u6362\u70ed\u5668\uff09<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8282\u6d41\u88c5\u7f6e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u529f\u80fd<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5438\u6536\u5ba4\u5916\u7a7a\u6c14\u70ed\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63d0\u5347\u51b7\u5a92\u538b\u529b\u548c\u6e29\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c06\u51b7\u5a92\u70ed\u91cf\u4f20\u9012\u7ed9\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u964d\u538b\u964d\u6e29\uff0c\u5b8c\u6210\u5faa\u73af<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8fd0\u884c\u6e29\u5ea6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6e29\u4f4e\u538b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u6e29\u9ad8\u538b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u6e29\u4e2d\u538b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6e29\u4f4e\u538b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u603b\u8fd0\u884c\u8d39\u7528\u5bf9\u6bd4\uff08100\u33a1\u5730\u6696\uff0c120\u5929\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b63\u8d39\u7528<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6bd4\u7a7a\u6c14\u80fd\u591a\u82b1<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u666e\u901a\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">3,780\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">+1,380\u5143\/\u5e74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">3,156\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">+756\u5143\/\u5e74<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u6c14\u80fd\uff08COP 3.0\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>2,400\u5143<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">20\u5e74\u603b\u6295\u5165\u5bf9\u6bd4\uff08\u6838\u5fc3\u7ed3\u8bba\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u521d\u88c5\u6210\u672c<\/th><th class=\"has-text-align-left\" data-align=\"left\">20\u5e74\u603b\u6295\u5165<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6bd4\u7a7a\u6c14\u80fd\u591a\u82b1<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bff\u547d\u4f30\u7b97<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u666e\u901a\u7089 (24kW)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea69,700\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea695,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">+35,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">8-10\u5e74\uff08\u9700\u66f4\u63621\u6b21\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51b7\u51dd\u7089 (25kW)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea612,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea687,100\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">+27,100\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\">8-10\u5e74\uff08\u9700\u66f4\u63621\u6b21\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u6c14\u80fd\u6c34\u6a21\u5757<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ea612,000\u5143<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ea660,000\u5143<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>20\u5e74+<\/strong>\uff08\u65e0\u9700\u66f4\u6362\u4e3b\u673a\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u7a7a\u6c14\u80fd\u662f\u957f\u671f\u6700\u4f18\u9009\u62e9<\/strong>\uff1a\u867d\u7136\u521d\u88c5\u6210\u672c\u4e0e\u51b7\u51dd\u7089\u76f8\u5f53\uff0c\u4f46\u7531\u4e8e\u5176\u6781\u9ad8\u7684\u80fd\u6548\u6bd4\uff08COP 3-4\uff09\uff0c20\u5e74\u603b\u6295\u5165\u6700\u4f4e\uff086\u4e07\u5143\uff09\uff0c\u542b\u8bbe\u5907\u66f4\u6362\u6210\u672c\u3002\u5bf9\u957f\u671f\u81ea\u4f4f\u7684\u7528\u6237\uff0c\u8fd9\u662f\u6700\u5212\u7b97\u7684\u6295\u8d44\u3002<\/li>\n\n<li><strong>\u51b7\u51dd\u7089\u4f18\u4e8e\u666e\u901a\u7089<\/strong>\uff1a\u572820\u5e74\u7ef4\u5ea6\u4e0a\uff0c\u51b7\u51dd\u7089\u7684\u603b\u6295\u5165\u6bd4\u666e\u901a\u7089\u4f4e\u7ea61.2\u4e07\u5143\u3002\u5982\u679c\u9884\u7b97\u5141\u8bb8\uff0c\u5efa\u8bae\u4f18\u5148\u8003\u8651\u51b7\u51dd\u7089\u3002<\/li>\n\n<li><strong>\u201c\u4fbf\u5b9c\u201d\u7684\u7089\u5b50\u53ef\u80fd\u66f4\u8d35<\/strong>\uff1a\u666e\u901a\u7089\u867d\u7136\u521d\u88c5\u4fbf\u5b9c\uff0c\u4f46\u957f\u671f\u8fd0\u884c\u6210\u672c\u6700\u9ad8\u3002\u7528\u6237\u5e94\u770b\u5230\u201c20\u5e74\u603b\u8d26\u201d\uff0c\u800c\u975e\u53ea\u770b\u201c\u4e00\u6b21\u4ef7\u683c\u201d\u3002<\/li>\n<\/ol>\n\n<h4 class=\"wp-block-heading\">\u4ea7\u54c1\u7c7b\u578b<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4ea7\u54c1\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u4f18\u52bf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u8bc1\u6587\u4ef6\u6765\u6e90<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e5\u7acb\u6c34\u5885\u9002VF<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u522b\u5885\u3001\u5927\u5e73\u5c42<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u53d8\u9891\uff0c-35\u2103\u8d85\u4f4e\u6e29\u5f3a\u70ed\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u65b0\u6c34\u5885\u9002\u6837\u518c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e5\u7acb\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8ffd\u6c42\u201c\u5929\u6c1f\u5730\u6c34\u201d\u7684\u8212\u9002\u4e0e\u9ad8\u6548<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u8c03(\u6c1f)\u5236\u51b7\u5feb\uff0c\u5730\u6696(\u6c34)\u8212\u9002\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161\u6837\u518c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ea2\u7130III\u7cfb\u5217<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u590f\u70ed\u51ac\u51b7\u53ca\u5bd2\u51b7\u5730\u533a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65b0\u56fd\u68071\u7ea7\u80fd\u6548\uff0c-35\u2103\u53ef\u9760\u8fd0\u884c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u65b0\u6c34\u5885\u9002\u6837\u518c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>COP\u968f\u51fa\u6c34\u6e29\u5ea6\u53d8\u5316<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\">\u7a7a\u6c14\u80fdCOP\u968f\u51fa\u6c34\u6e29\u5ea6\u53d8\u5316\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u51fa\u6c34\u6e29\u5ea6<\/th><th>COP<\/th><th>\u9002\u7528\u672b\u7aef<\/th><th>\u8bc4\u7ea7<\/th><\/tr><\/thead><tbody><tr><td>35\u2103<\/td><td>4.0-4.5<\/td><td>\u5730\u6696<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u6700\u9ad8\u6548\u533a\u95f4<\/td><\/tr><tr><td>45\u2103<\/td><td>3.5-4.0<\/td><td>\u5730\u6696<\/td><td>\u2605\u2605\u2605\u2605 \u4ecd\u9ad8\u6548<\/td><\/tr><tr><td>55\u2103<\/td><td>2.5-3.0<\/td><td>\u4f4e\u6e29\u6696\u6c14\u7247<\/td><td>\u2605\u2605\u2605 \u6548\u7387\u4e0b\u964d\u660e\u663e<\/td><\/tr><tr><td>65\u2103\u4ee5\u4e0a<\/td><td>\uff1c2.0<\/td><td>\u4f20\u7edf\u6696\u6c14\u7247<\/td><td>\u2605 \u4e0d\u63a8\u8350\uff0c\u4e0e\u7535\u52a0\u70ed\u65e0\u5f02<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u7ed3\u8bba\uff1a\u7a7a\u6c14\u80fd\u5730\u6696\u5fc5\u987b\u914d\u5408\u4f4e\u6e29\u672b\u7aef\u624d\u80fd\u53d1\u6325\u8282\u80fd\u4f18\u52bf\u3002<\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\"><strong>COP\u968f\u5ba4\u5916\u6e29\u5ea6\u53d8\u5316\uff1a<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5ba4\u5916\u6e29\u5ea6<\/th><th>\u666e\u901a\u673a\u578bCOP<\/th><th>\u8865\u6c14\u589e\u7113\u673a\u578bCOP<\/th><th>\u9002\u7528\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td>15\u2103<\/td><td>4.5-5.0<\/td><td>\u2014<\/td><td>\u6625\u79cb\u8fc7\u6e21\u5b63<\/td><\/tr><tr><td>7\u2103<\/td><td>3.8-4.2<\/td><td>4.0-4.5<\/td><td>\u957f\u6c5f\u6d41\u57df\u51ac\u5b63\u5e38\u6001<\/td><\/tr><tr><td>0\u2103<\/td><td>3.0-3.5<\/td><td>3.5-4.0<\/td><td>\u534e\u5317\u51ac\u5b63\u5e38\u6001<\/td><\/tr><tr><td>-7\u2103<\/td><td>2.2-2.5<\/td><td>2.8-3.2<\/td><td>\u5317\u65b9\u5bd2\u51b7<\/td><\/tr><tr><td>-15\u2103<\/td><td>1.5-1.8<\/td><td>2.2-2.5<\/td><td>\u4e1c\u5317\u4e25\u5bd2<\/td><\/tr><tr><td>-20\u2103<\/td><td>\uff1c1.5<\/td><td>2.0-2.2<\/td><td>\u4e0d\u5efa\u8bae\u5355\u72ec\u4f7f\u7528<\/td><\/tr><tr><td>-30\u2103<\/td><td>\u2014<\/td><td>1.8-2.0\uff08\u8d85\u4f4e\u6e29\u4e13\u7528\u673a\u578b\uff09<\/td><td>\u4e1c\u5317\u6781\u5bd2\u53ef\u7528\u4f46\u6548\u7387\u4f4e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">3.5 \u7535\u80fd\u91c7\u6696\u7cfb\u7edf<\/h3>\n\n<p class=\"wp-block-paragraph\">\u7535\u80fd\u4f9b\u6696\u662f\u6700\u6e05\u6d01\u3001\u6700\u7075\u6d3b\u7684\u65b9\u6848\uff0c\u9002\u7528\u4e8e\u65e0\u6c14\u6e90\u3001\u5c0f\u6237\u578b\u6216\u8001\u623f\u6539\u9020\u573a\u666f\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">\u70ed\u6e90\u5bf9\u6bd4<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53d1\u70ed\u539f\u7406<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5347\u6e29\u901f\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u521d\u88c5\u6210\u672c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u7528<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f18\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c40\u9650<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53d1\u70ed\u7535\u7f06<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7535\u6d41\u901a\u8fc7\u5bfc\u4f53\u53d1\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d\uff080.5-2\u5c0f\u65f6\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">5-50\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94fa\u8bbe\u7075\u6d3b\uff0c\u65e0\u7535\u78c1\u8f90\u5c04<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u9ad8\uff0c\u9700\u914d\u5408\u6e29\u63a7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7535\u70ed\u819c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fdc\u7ea2\u5916\u8f90\u5c04\u52a0\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5feb\uff0830\u5206\u949f-1\u5c0f\u65f6\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e2d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\">5-50\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f53\u611f\u8212\u9002\uff0c\u5347\u6e29\u5feb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u6ce8\u610f\u5730\u9762\u8986\u76d6\u8981\u6c42<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u5173\u952e\u6ce8\u610f\u4e8b\u9879<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u8fd0\u884c\u8d39\u7528\u9ad8<\/strong>\uff1a\u7535\u80fd\u91c7\u6696\u662f1:1\u7684\u80fd\u91cf\u8f6c\u5316\uff0c\u8fd0\u884c\u8d39\u7528\u662f\u71c3\u6c14\u9505\u7089\u76842-3\u500d\uff0c\u662f\u7a7a\u6c14\u80fd\u76844-5\u500d\u3002<strong>\u53ea\u63a8\u8350\u4f5c\u4e3a\u5c40\u90e8\u8865\u5145\u6216\u7279\u5b9a\u573a\u666f\u4f7f\u7528\u3002<\/strong><\/li>\n\n<li><strong>\u4e25\u7981\u5207\u5272\u6216\u62fc\u63a5<\/strong>\uff1a\u53d1\u70ed\u7535\u7f06\u548c\u7535\u70ed\u819c\u7684\u51b7\u3001\u70ed\u63a5\u5934\u5fc5\u987b\u57cb\u5728\u8ddd\u79bb\u63a5\u7ebf\u76d2300-500mm\u8303\u56f4\u5185\uff0c\u4e25\u7981\u5207\u5272\u6216\u62fc\u63a5\uff0c\u5426\u5219\u6709\u77ed\u8def\u8d77\u706b\u98ce\u9669\u3002<\/li>\n\n<li><strong>\u9a8c\u6536\u6807\u51c6<\/strong>\uff1a\u65bd\u5de5\u5b8c\u6210\u540e\uff0c\u9700\u8fdb\u884c\u6253\u538b\u6d4b\u8bd5\u6216\u901a\u7535\u6d4b\u8bd5\uff0c\u786e\u4fdd\u5730\u9762\u6e29\u5ea6\u572824-26\u2103\u4e3a\u5b9c\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u7535\u5730\u6696\u6df1\u5ea6\u89e3\u6790\u2014\u2014\u5c0f\u9762\u79ef\u573a\u666f\u7684\u4e0d\u53ef\u66ff\u4ee3\u6027<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">\u7535\u5730\u6696\u4e0d\u53ef\u66ff\u4ee3\u7684\u539f\u56e0<\/h4>\n\n<p class=\"wp-block-paragraph\">\u7a7a\u6c14\u80fd\u53d7\u4e24\u4e2a\u786c\u7ea6\u675f\uff0c30\u33a1\u4ee5\u4e0b\u5fae\u578b\u573a\u666f\u7535\u5730\u6696\u4f18\u52bf\u66f4\u660e\u663e\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ea6\u675f<\/th><th>\u7a7a\u6c14\u80fd\u60c5\u51b5<\/th><th>\u7535\u5730\u6696\u4f18\u52bf<\/th><\/tr><\/thead><tbody><tr><td>\u8bbe\u5907\u6700\u4f4e\u529f\u7387<\/td><td>\u6700\u5c0f\u578b\u53f7\u901a\u5e388kW\u8d77\uff0c20-30\u33a1\u5b9e\u9645\u70ed\u9700\u6c42\u4ec52-3kW\uff0c\u4e25\u91cd\u5927\u9a6c\u62c9\u5c0f\u8f66<\/td><td>\u529f\u7387\u5339\u914d\u7075\u6d3b<\/td><\/tr><tr><td>\u521d\u88c5\u6210\u672c\u95e8\u69db<\/td><td>\u4e3b\u673a+\u6c34\u6a21\u5757+\u76d8\u7ba1+\u5b89\u88c5 \u2265 2.5\u4e07\u5143\uff0c20\u33a1\u91c7\u6696\u6027\u4ef7\u6bd4\u6781\u4f4e<\/td><td>0.8-1.5\u4e07\u5143\uff0c\u521d\u88c5\u6210\u672c\u4f4e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u5173\u4e8e\"\u77f3\u58a8\u70ef\u5730\u6696\"\u7684\u6280\u672f\u771f\u76f8<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6982\u5ff5<\/th><th>\u5b9e\u9645\u60c5\u51b5<\/th><\/tr><\/thead><tbody><tr><td>\u771f\u6b63\u7684\u77f3\u58a8\u70ef<\/td><td>\u5355\u5c42\u78b3\u539f\u5b50\u4e8c\u7ef4\u6676\u4f53\uff0c\u5de5\u4e1a\u7ea7\u7ea6200\u5143\/\u514b\uff0c\u9ad8\u7eaf\u5ea6\u7ea61200\u5143\/\u514b\uff0c\u91cf\u4ea7\u6781\u5176\u56f0\u96be<\/td><\/tr><tr><td>\"\u77f3\u58a8\u70ef\u5730\u6696\"<\/td><td>\u5b9e\u4e3a\u78b3\u57fa\u6cb9\u58a8\u7535\u70ed\u819c\uff0c\u5728\u666e\u901a\u7535\u70ed\u819c\u6d46\u6599\u4e2d\u63ba\u5165\u5fae\u91cf\u77f3\u58a8\u7c89\/\u77f3\u58a8\u70ef\u7c89\u4f53\uff08\u542b\u91cf\u6781\u4f4e\uff09<\/td><\/tr><tr><td>\"\u78b3\u6676\"\"\u78b3\u7d20\"\"\u77f3\u58a8\u70ef\"<\/td><td>\u5747\u975e\u4e13\u4e1a\u6280\u672f\u672f\u8bed\uff0c\u53ea\u662f\u5546\u5bb6\u8425\u9500\u6982\u5ff5\u5305\u88c5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u7535\u70ed\u819c\u7684\u6838\u5fc3\u5b89\u5168\u98ce\u9669<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u98ce\u9669\u70b9<\/th><th>\u539f\u56e0<\/th><th>\u540e\u679c<\/th><\/tr><\/thead><tbody><tr><td>\u9897\u7c92\u55b7\u6d82\u4e0d\u5747\u5300<\/td><td>\u5c40\u90e8\u7535\u963b\u8fc7\u9ad8\u6216\u8fc7\u4f4e<\/td><td>\u5c40\u90e8\u8fc7\u70ed\u2192\u5f15\u71c3<\/td><\/tr><tr><td>\u8f7d\u4f53\u8d28\u91cf\u5dee<\/td><td>\u5bfc\u7535\u6750\u6599\u8131\u843d\u5f62\u6210\u65b0\u901a\u8def<\/td><td>\u77ed\u8def\u6216\u6f0f\u7535<\/td><\/tr><tr><td>\u63a5\u5934\u8fc7\u591a<\/td><td>\u591a\u5757\u819c\u7247\u62fc\u63a5\uff0c\u6bcf\u4e2a\u63a5\u5934\u90fd\u662f\u6f5c\u5728\u6545\u969c\u70b9<\/td><td>\u6253\u706b\u3001\u6f0f\u7535<\/td><\/tr><tr><td>\u6563\u70ed\u4e0d\u826f<\/td><td>\u88ab\u5bb6\u5177\u8986\u76d6\u540e\u70ed\u91cf\u79ef\u805a<\/td><td>\u6e29\u5ea6\u6301\u7eed\u5347\u9ad8\u5f15\u71c3\u53ef\u71c3\u7269<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u6838\u5fc3\u6d1e\u5bdf\uff1a\u7a7a\u6c14\u80fd\u548c\u7535\u5730\u6696\u5728\u6e05\u6d01\u80fd\u6e90\u4f9b\u7535\u4e0b\u90fd\u662f\u96f6\u78b3\u6392\u653e\u3002\u7a7a\u6c14\u80fd\u80dc\u5728\"\u80fd\u6548\u642c\u8fd0\"\u2014\u2014\u5927\u9762\u79ef\u573a\u666f\u4e0b\u8fd0\u884c\u8d39\u7528\u4f4e\u4e8e\u7535\u5730\u6696\uff1b\u4f46\u572830\u33a1\u4ee5\u4e0b\u5fae\u578b\u91c7\u6696\u573a\u666f\uff0c\u7535\u5730\u6696\u7684\u7075\u6d3b+\u4f4e\u521d\u88c5\u4f18\u52bf\u4ecd\u7136\u4e0d\u53ef\u53d6\u4ee3\u3002\u9009\u62e9\u53d6\u51b3\u4e8e\u9762\u79ef\u548c\u9884\u7b97\u2014\u2014\u6ca1\u6709\u7edd\u5bf9\u7684\"\u8c01\u66f4\u597d\"\uff0c\u53ea\u6709\"\u8c01\u66f4\u5408\u9002\"\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">3.6 \u70ed\u6e90\u9009\u578b\u4e09\u539f\u5219\u4e0e\u62a5\u8b66\u6761\u4ef6<\/h3>\n\n<h4 class=\"wp-block-heading\">\u201c\u4e09\u539f\u5219\u201d<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u539f\u5219<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u4ef7\u503c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8fdd\u53cd\u540e\u679c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6700\u5927\u529f\u7387\u5339\u914d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9009\u578b\u529f\u7387 \u2265 \u70ed\u8d1f\u8377\uff0c\u4f46\u8d85\u51fa\u90e8\u5206\u226430%\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u51b7\u5929\u4e5f\u80fd\u70ed\u8d77\u6765\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d85\u51fa\u8d8a\u591a\uff0c\u9891\u7e41\u542f\u505c\u8d8a\u4e25\u91cd\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6700\u5c0f\u8f93\u51fa\u5339\u914d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u8f93\u51fa\u529f\u7387 \u2264 \u5ba4\u5185\u5e38\u7528\u8d1f\u8377\uff08\u901a\u5e38\u4e3a\u70ed\u8d1f\u8377\u768430-50%\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u907f\u514d\u4f4e\u70ed\u8d1f\u8377\u65f6\u7684\u9891\u7e41\u542f\u505c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u5c0f\u8f93\u51fa\u8fc7\u9ad8\u2192\u9891\u7e41\u542f\u505c\uff0c\u80fd\u8017\u98d9\u5347\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7981\u6b62\u8fc7\u5ea6\u914d\u7f6e<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u7981\u4e3a\u201c\u7559\u4f59\u91cf\u201d\u9009\u62e9\u5927\u4e24\u7ea7\u4ee5\u4e0a\u7684\u578b\u53f7\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8282\u80fd\u7701\u6c14\uff0c\u8bbe\u5907\u5bff\u547d\u66f4\u957f\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u80fd\u8017\u98d9\u5347\uff0c\u5bff\u547d\u7f29\u77ed\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">\u70ed\u6e90\u9009\u578b\u4e13\u5c5e\u62a5\u8b66\u6761\u4ef6\uff08\u81ea\u52a8\u6821\u9a8c\u6e05\u5355\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\">\u5f53\u4ee5\u4e0b\u4efb\u4e00\u6761\u4ef6\u89e6\u53d1\u65f6\uff0c\u8bf4\u660e\u70ed\u6e90\u9009\u578b\u5b58\u5728\u91cd\u5927\u98ce\u9669\uff0c\u5fc5\u987b\u91cd\u65b0\u8bbe\u8ba1\u65b9\u6848\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u9505\u7089\u9009\u578b\u529f\u7387 &gt; \u8bbe\u8ba1\u70ed\u8d1f\u8377 \u00d7 1.3<\/strong>\uff08\u8d85\u51fa30%\u4ee5\u4e0a\uff09\u3002<\/li>\n\n<li><strong>\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387 &gt; \u8bbe\u8ba1\u70ed\u8d1f\u8377 \u00d7 0.5<\/strong>\uff08\u6700\u5c0f\u529f\u7387\u9ad8\u4e8e\u9700\u6c42\u7684\u4e00\u534a\uff09\u3002<\/li>\n\n<li><strong>\u91c7\u6696\u9762\u79ef \u2264 150\u33a1\uff0c\u4f46\u9009\u578b\u529f\u7387 \u2265 28kW\uff08\u4e24\u7528\u7089\uff09<\/strong>\uff08\u89e6\u72af\u201c\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u201d\u7ea2\u7ebf\uff09\u3002<\/li>\n\n<li><strong>\u51b7\u51dd\u7089\u7cfb\u7edf\u672a\u914d\u7f6e\u5ba4\u5916\u6e29\u5ea6\u8865\u507f\u6216\u6c14\u5019\u8865\u507f\u529f\u80fd<\/strong>\uff08\u65e0\u6cd5\u5728\u4f4e\u6e29\u73af\u5883\u4e0b\u5f00\u542f\u540e\u9ad8\u6548\u8fd0\u884c\uff09\u3002<\/li>\n<\/ol>\n\n<h3 class=\"wp-block-heading\">3.7 <strong>\u4e09\u5927\u70ed\u6e90\u9635\u8425\u5168\u666f\u5bf9\u6bd4<\/strong><\/h3>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ef4\u5ea6<\/th><th>\u71c3\u6c14\u58c1\u6302\u7089<\/th><th>\u7a7a\u6c14\u80fd\u70ed\u6cf5<\/th><th>\u7535\u5730\u6696<\/th><\/tr><\/thead><tbody><tr><td>\u6838\u5fc3\u539f\u7406<\/td><td>\u71c3\u70e7\u5929\u7136\u6c14\u52a0\u70ed\u5faa\u73af\u6c34<\/td><td>\u5438\u6536\u7a7a\u6c14\u70ed\u80fd\uff0c\u538b\u7f29\u673a\u642c\u8fd0\u81f3\u6c34\u4e2d<\/td><td>\u7535\u80fd\u76f4\u63a5\u8f6c\u5316\u4e3a\u70ed\u80fd\uff08\u7126\u8033\u70ed\uff09<\/td><\/tr><tr><td>\u80fd\u6548\u6bd4<\/td><td>\u70ed\u6548\u738785%-105%\uff08\u51b7\u51dd\u7089\uff09<\/td><td>COP 3.0-4.0\uff08\u5e38\u6e29\uff09<\/td><td>\u7ea60.95-0.98\uff081\u5ea6\u7535=1\u5ea6\u70ed\uff09<\/td><\/tr><tr><td>\u78b3\u6392\u653e<\/td><td>\u8f83\u9ad8\uff08\u6bcf\u91c7\u6696\u5b632500-3000kg CO\u2082\uff09<\/td><td>\u4ec5\u4e3a\u71c3\u6c14\u76841\/3<\/td><td>\u53d6\u51b3\u4e8e\u53d1\u7535\u7ed3\u6784\uff08\u706b\u7535\u533a\u6bd4\u71c3\u6c14\u9ad82\u500d+\uff09<\/td><\/tr><tr><td>100\u33a1\u6708\u8fd0\u884c\u8d39<\/td><td>780-1300\u5143<\/td><td>450-650\u5143<\/td><td>1200-1800\u5143<\/td><\/tr><tr><td>\u521d\u88c5\u8d39\u7528<\/td><td>1.5-2.5\u4e07\u5143\uff08\u542b\u9505\u7089+\u76d8\u7ba1+\u5b89\u88c5\uff09<\/td><td>2.5-4.0\u4e07\u5143\uff08\u542b\u4e3b\u673a+\u6c34\u6a21\u5757+\u76d8\u7ba1\uff09<\/td><td>0.8-1.5\u4e07\u5143\uff08\u53d1\u70ed\u4f53+\u6e29\u63a7\u5668+\u94fa\u8bbe\uff09<\/td><\/tr><tr><td>\u5347\u6e29\u901f\u5ea6<\/td><td>\u6162\uff082-4\u5c0f\u65f6\uff0c\u50a8\u70ed\u5f0f\uff09<\/td><td>\u6162\uff08\u540c\u6c34\u5730\u6696\uff09<\/td><td>\u5feb\uff0830\u5206\u949f-1\u5c0f\u65f6\uff09<\/td><\/tr><tr><td>\u9002\u7528\u9762\u79ef<\/td><td>\u226580\u33a1\uff08\u5927\u9762\u79ef\u7ecf\u6d4e\u6027\u66f4\u597d\uff09<\/td><td>\u2265100\u33a1\uff08\u5206\u644a\u8bbe\u5907\u6210\u672c\uff09<\/td><td>5-50\u33a1\uff08\u5c0f\u9762\u79ef\u7075\u6d3b\u4f18\u52bf\uff09<\/td><\/tr><tr><td>\u7ef4\u62a4\u9700\u6c42<\/td><td>\u6bcf\u5e74\u4fdd\u517b\u9505\u7089\u30012-3\u5e74\u6e05\u6d17\u7ba1\u9053<\/td><td>\u6bcf\u5e74\u68c0\u67e5\u4e3b\u673a\u3001\u6e05\u6d17\u8fc7\u6ee4\u7f51<\/td><td>\u51e0\u4e4e\u514d\u7ef4\u62a4<\/td><\/tr><tr><td>\u4f4e\u6e29\u6027\u80fd<\/td><td>\u4e0d\u53d7\u5ba4\u5916\u6e29\u5ea6\u5f71\u54cd<\/td><td>-5\u2103\u4ee5\u4e0bCOP\u4e0b\u964d\uff1b-20\u2103\u9700\u8865\u6c14\u589e\u7113\u673a\u578b<\/td><td>\u4e0d\u53d7\u5ba4\u5916\u6e29\u5ea6\u5f71\u54cd<\/td><\/tr><tr><td>\u751f\u6d3b\u70ed\u6c34<\/td><td>\u53ef\u9009\u4e24\u7528\u7089\uff08\u91c7\u6696+\u70ed\u6c34\u4e00\u4f53\uff09<\/td><td>\u9700\u53e6\u914d\u70ed\u6c34\u5668<\/td><td>\u4e0d\u652f\u6301<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u56db\u7ae0\uff1a\u8f93\u914d\u3001\u672b\u7aef\u4e0e\u63a7\u5236\u2014\u2014\u4ece\u201c\u4ea7\u70ed\u201d\u5230\u201c\u7528\u70ed\u201d\u7684\u5b8c\u6574\u94fe\u8def<\/h2>\n\n<p class=\"wp-block-paragraph\">\u6c34\u7cfb\u7edf\u5730\u6696\u70ed\u6e90\u8d1f\u8d23\u201c\u4ea7\u70ed\u201d\uff0c\u4f46\u5149\u4ea7\u70ed\u662f\u4e0d\u591f\u7684\u3002\u4ea7\u51fa\u7684\u70ed\u80fd\u4e0d\u80fd\u9ad8\u6548\u3001\u5747\u5300\u5730\u8f93\u9001\u5230\u6bcf\u4e2a\u623f\u95f4\uff08\u8f93\u914d\uff09\uff0c\u80fd\u4e0d\u80fd\u5728\u623f\u95f4\u91cc\u88ab\u6709\u6548\u5229\u7528\u8d77\u6765\uff08\u672b\u7aef\uff09\uff0c\u4ee5\u53ca\u80fd\u4e0d\u80fd\u667a\u80fd\u5730\u6309\u9700\u542f\u505c\uff08\u63a7\u5236\uff09\uff0c\u8fd9\u4e09\u8005\u5171\u540c\u51b3\u5b9a\u4e86\u7cfb\u7edf\u7684\u6700\u7ec8\u6548\u679c\u3001\u7a33\u5b9a\u6027\u548c\u8282\u80fd\u6027\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u672c\u7ae0\u5c06\u628a\u6c34\u7cfb\u7edf\u5730\u6696\u7684\u8fd9\u4e09\u5927\u7cfb\u7edf\u8981\u7d20\u6574\u5408\u4e3a\u4e00\u4e2a\u5b8c\u6574\u94fe\u8def\u8fdb\u884c\u8bb2\u89e3\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">4.1 \u8f93\u914d\u7cfb\u7edf<\/h3>\n\n<p class=\"wp-block-paragraph\">\u8f93\u914d\u7cfb\u7edf\u662f\u8fde\u63a5\u70ed\u6e90\u548c\u672b\u7aef\u7684\u201c\u7269\u6d41\u901a\u9053\u201d\uff0c\u8d1f\u8d23\u5c06\u70ed\u6c34(\u51b7)\u8f93\u9001\u5230\u6bcf\u4e2a\u623f\u95f4\u7684\u5730\u6696\u76d8\u7ba1\u6216\u6696\u6c14\u7247\u3002\u5982\u679c\u8f93\u914d\u51fa\u4e86\u95ee\u9898\u2014\u2014\u4ea7\u7684\u70ed\u62c9\u4e0d\u8d70\uff0c\u70ed\u6e90\u81ea\u635f\uff08\u9891\u7e41\u542f\u505c\uff09\uff1b\u62c9\u6765\u7684\u70ed\u6563\u4e0d\u6389\uff0c\u5bb6\u91cc\u4e0d\u70ed\u3002<\/p>\n\n<h4 id=\"dnxt040101\" class=\"wp-block-heading\">4.1.1 \u7ba1\u9053\u6750\u6599\u77e9\u9635<\/h4>\n\n<p class=\"wp-block-paragraph\">\u7ba1\u9053\u662f\u8f93\u914d\u7cfb\u7edf\u7684\u201c\u8840\u7ba1\u201d\uff0c\u4e0d\u540c\u6750\u8d28\u51b3\u5b9a\u4e86\u7ba1\u9053\u7684\u8010\u6e29\u3001\u8010\u538b\u3001\u67d4\u97e7\u6027\u548c\u5bff\u547d\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u6750\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5173\u952e\u7279\u6027<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u4f18\u52bf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u98ce\u9669\/\u6ce8\u610f\u4e8b\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u8981\u5e94\u7528\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>PE-RT (\u8010\u70ed\u805a\u4e59\u70ef)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">I\u578b \/ II\u578b\uff08<a href=\"https:\/\/longmai-nt.com\/?page_id=2324\">\u4e86\u89e3\u4f1f\u661fII\u578b\u5730\u6696\u7ba1\u66f4\u591a\u70b9\u51fb\u2192<\/a>\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u67d4\u97e7\u6027\u597d\u3001\u53ef\u70ed\u7194\u8fde\u63a5\u3001\u73af\u4fdd\u53ef\u56de\u6536; II\u578b\u8010\u6e29\u8010\u538b\u66f4\u5f3a<\/td><td class=\"has-text-align-left\" data-align=\"left\">I\u578b\u957f\u671f\u8010\u6e29\u226460\u2103, II\u578b\u226480\u2103; I\u578b\u4e0d\u9002\u5408\u9ad8\u6e29\u96c6\u4e2d\u4f9b\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5730\u6696\u76d8\u7ba1\u9996\u9009<\/strong>: I\u578b\u7528\u4e8e\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd (\u226455\u2103)\uff1bII\u578b\u7528\u4e8e\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\/\u6696\u6c14\u7247 (\u8f83\u9ad8\u6e29)\u3002<a href=\"https:\/\/longmai-nt.com\/?page_id=2336\">I\u578bPERT\u5730\u6696\u7ba1\u8ddfII\u578b\u5730\u6696\u7ba1\u7684\u8be6\u7ec6\u5206\u6790\u8bf7\u70b9\u51fb\u2192<\/a><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>PE-X (\u4ea4\u8054\u805a\u4e59\u70ef)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">PE-Xa (\u8fc7\u6c27\u5316\u7269) \/ PE-Xb (\u7845\u70f7) \/ PE-Xc (\u7535\u5b50\u675f)<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8010\u9ad8\u6e29\u9ad8\u538b (\u53ef\u8fbe110\u2103)\uff1b\u5177\u6709\u201c\u8bb0\u5fc6\u529f\u80fd\u201d\uff1b\u6297\u8815\u53d8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u80fd\u70ed\u7194\uff0c\u9700\u4e13\u7528\u673a\u68b0\u63a5\u5934\uff1b\u4f4e\u4ef7\u4ea7\u54c1\u5b58\u5728\u56de\u6536\u6599\u98ce\u9669<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6563\u70ed\u5668\u8fde\u63a5\u3001\u9ad8\u6e29\u4f9b\u6696\u7cfb\u7edf\u3001\u4e5f\u53ef\u7528\u4e8e\u5730\u6696\u76d8\u7ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u94dd\u5851\u590d\u5408\u7ba1 (PAP\/XPAP)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">PE\/AL\/PE \u6216 PEX\/AL\/PEX<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5929\u7136\u7edd\u6c27<\/strong>\u3001\u5c3a\u5bf8\u7a33\u5b9a\u3001\u5f2f\u66f2\u540e\u4fdd\u6301\u5f62\u72b6\u3001\u8fde\u63a5\u53ef\u9760<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u4ef7\u4ea7\u54c1\u5b58\u5728\u7ba1\u5f84\u7f29\u6c34 (16\u4ee320)\uff1b\u5927\u7ba1\u5f84\u67d4\u97e7\u6027\u4e0b\u964d\uff1b\u4ef7\u683c\u8f83\u9ad8<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6696\u6c14\u7247\u652f\u7ba1\/\u4e3b\u7ba1\u9996\u9009<\/strong>\uff1b\u5168\u5c4b\u7edd\u6c27\u7cfb\u7edf\uff1b\u5730\u6696\u4e3b\u7ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>PPR &amp; F-PPR (\u65e0\u89c4\u5171\u805a\u805a\u4e19\u70ef)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">S5 \/ S4 \/ S3.2 (\u58c1\u539a\u7b49\u7ea7)<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ecf\u6d4e\u5b9e\u60e0\u3001\u70ed\u7194\u8fde\u63a5\u53ef\u9760\u3001\u5e94\u7528\u5e7f\u6cdb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u58c1\u539a\u8f83\u539a\u3001\u7ebf\u81a8\u80c0\u7cfb\u6570\u5927\u3001\u8010\u4f4e\u6e29\u6027\u80fd\u5dee\u3001\u4e0d\u5b9c\u5f2f\u66f2<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u8c03\u4e3b\u7ba1\u9053\u9996\u9009 (S3.2)<\/strong>\uff1b\u751f\u6d3b\u70ed\u6c34\u7ba1\uff1b\u4e0d\u63a8\u8350\u7528\u4e8e\u5730\u6696\u76d8\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u77e5\u8bc6\u70b9<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u963b\u6c27\u662f\u7ea2\u7ebf<\/strong>\uff1a\u6839\u636e\u300a\u9f99\u8109\u6696\u901a\u300b\u8bbe\u8ba1\u89c4\u8303\uff0c<strong>\u4e0e\u94a2\u5236\u6563\u70ed\u5668\u8054\u5408\u4f9b\u6696\u65f6\uff0c\u5fc5\u987b\u91c7\u7528\u94dd\u5851\u590d\u5408\u7ba1\u6216\u5e26\u963b\u6c27\u5c42\uff08EVOH\uff09\u7684\u5851\u6599\u7ba1\u6750<\/strong>\uff0c\u5426\u5219\u94a2\u5236\u6563\u70ed\u5668\u4f1a\u56e0\u6c27\u6c14\u8150\u8680\u800c\u8fc5\u901f\u7a7f\u5b54\u6f0f\u6c34\u3002<\/li>\n\n<li><strong>PE-RT vs PE-X<\/strong>: PE-RT\u56e0\u65bd\u5de5\u65b9\u4fbf\uff08\u70ed\u7194\uff09\u6210\u4e3a\u5bb6\u88c5\u5730\u6696\u76d8\u7ba1\u7edd\u5bf9\u4e3b\u6d41\uff1bPE-X\u56e0\u8010\u9ad8\u6e29\u80fd\u529b\u5f3a\uff0c\u662f\u6563\u70ed\u5668\u7cfb\u7edf\u7684\u7406\u60f3\u9009\u62e9\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u963b\u6c27\u7ba1\u2014\u2014\u4e00\u4e2a\u4e0d\u53ef\u5ffd\u89c6\u7684\"\u9690\u6027\u5de5\u7a0b\"<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ba1\u9053\u7c7b\u578b<\/th><th>\u6c27\u6c14\u6e17\u900f\u7387<\/th><th>\u5f71\u54cd<\/th><th>\u7ed3\u8bba<\/th><\/tr><\/thead><tbody><tr><td>\u666e\u901aPERT\u7ba1<\/td><td>\u9ad8<\/td><td>\u6c27\u6c14\u6e17\u900f\u2192\u7ba1\u9053\u5185\u58c1\u6c27\u5316\u2192\u94c1\u9508+\u9ed1\u6c34+\u5fae\u751f\u7269\u6ecb\u751f\u2192\u7ba1\u58c1\u7ed3\u57a2\u2192\u4f20\u70ed\u6548\u7387\u4e0b\u964d30%+<\/td><td>\u2014<\/td><\/tr><tr><td>\u963b\u6c27PERT\/PE-X\u7ba1\uff08EVOH\u963b\u6c27\u5c42\uff09<\/td><td>\u6781\u4f4e\uff08\u22640.1g\/m\u00b3\u00b7d\uff0c\u7b26\u5408DIN 4726\u6807\u51c6\uff09<\/td><td>\u7ba1\u9053\u5185\u58c1\u4fdd\u6301\u6d01\u51c0\uff0c15\u5e74\u4ee5\u4e0a\u4f20\u70ed\u6548\u7387\u57fa\u672c\u4e0d\u53d8<\/td><td>5\u5143\u7684\u963b\u6c27\u7ba1\u5dee\u4ef7\uff0c5\u5e74\u540e\u53ef\u80fd\u7701\u4e0b\u51e0\u5343\u5143\u7684\u7ba1\u9053\u6e05\u6d17\u8d39\u548c\u4e0d\u8fbe\u6807\u5ba4\u6e29\u7684\u75db\u82e6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">4.1.2 \u7ba1\u5f84\u9009\u62e9\uff08De16 vs De20\uff1b\u4e3b\u7ba1De32\/De25\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\">\u7ba1\u5f84\u9009\u62e9\u76f4\u63a5\u5f71\u54cd\u7cfb\u7edf\u6d41\u91cf\u548c\u8f93\u914d\u80fd\u529b\u3002<\/p>\n\n<h5 class=\"wp-block-heading\"><strong>1. \u5730\u6696\u76d8\u7ba1\u7ba1\u5f84\u9009\u62e9<\/strong><\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u5f84<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e94\u7528\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u56de\u8def\u6700\u5927\u9762\u79ef (\u53c2\u8003)<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u56de\u8def\u6700\u5927\u957f\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u6027<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De16 (\u5e38\u7528)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">100\u33a1\u4ee5\u4e0b\u4e2d\u5c0f\u6237\u578b<\/td><td class=\"has-text-align-left\" data-align=\"left\">10-15\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">80-100m<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6027\u4ef7\u6bd4\u9ad8\uff0c\u65bd\u5de5\u65b9\u4fbf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De20 (\u63a8\u8350)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">100\u33a1\u4ee5\u4e0a\u5927\u6237\u578b\u3001\u522b\u5885<\/td><td class=\"has-text-align-left\" data-align=\"left\">15-20\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">120-150m<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5927\u6d41\u91cf\u3001\u5c0f\u6e29\u5dee<\/strong>\uff0c\u7cfb\u7edf\u66f4\u7a33\u5b9a\uff0c\u53ef\u51cf\u5c11\u56de\u8def\u6570<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u77e5\u8bc6\u70b9<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u201c\u5c0f\u6237\u578b\u752816\u7ba1\uff0c\u5927\u5e73\u5c42\/\u522b\u5885\u752820\u7ba1\uff0c\u53ef\u6df7\u7528 (\u4e3b\u7ba120, \u652f\u7ba116)\u201d<\/strong> (\u53c2\u8003\u81ea\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u89c4\u8303)\u3002De20\u53ef\u4ee5\u627f\u8f7d\u66f4\u5927\u7684\u70ed\u8d1f\u8377\uff0c\u4e14\u66f4\u4e0d\u6613\u5835\u585e\u3002<\/li>\n\n<li><strong>\u4e3b\u7ba1\u5347\u7ea7\u662f\u5173\u952e<\/strong>\uff1a\u4f20\u7edf\u201c25\u7ba1\u8d70\u5929\u4e0b\u201d\u7684\u6a21\u5f0f\u5df2\u4e0d\u9002\u7528\u3002\u6839\u636e\u300a\u4e09\u65b9\u6848\u5bf9\u6bd4\u5efa\u8bae\u4e66\uff08\u542b\u7ba1\u5f84\u80fd\u8017\u5206\u6790\uff09\u300b\uff0c<strong>\u4e3b\u7ba1\u4f18\u5148\u91c7\u7528De32<\/strong>\uff0c\u6d41\u91cf\u53ef\u63d0\u534760%\u4ee5\u4e0a\uff0c\u5f7b\u5e95\u89e3\u51b3\u201c\u8fd0\u4e0d\u8d70\u201d\u7684\u95ee\u9898\u3002<\/li>\n<\/ul>\n\n<h5 class=\"wp-block-heading\"><strong>2. \u4e3b\u7ba1\u7ba1\u5f84\u9009\u62e9\uff08\u7528\u4e8e\u5206\u96c6\u6c34\u5668\u524d\u540e\u8fde\u63a5\u70ed\u6e90\uff09<\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">\u4e3b\u7ba1\u7ba1\u5f84\u9700\u6839\u636e\u7cfb\u7edf\u603b\u6d41\u91cf\u548c\u8ddd\u79bb\u8fdb\u884c\u6c34\u529b\u8ba1\u7b97\uff0c\u4ee5\u4e0b\u662f\u63a8\u8350\u914d\u7f6e\u53c2\u8003\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4f9b\u6696\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u7ba1\u7ba1\u5f84\u5efa\u8bae<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u4f9d\u636e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">&lt; 100\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">De25<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6ee1\u8db3\u57fa\u672c\u6d41\u91cf\u9700\u6c42\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">100-200\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>De32<\/strong> (\u4f18\u5148\u63a8\u8350) \/ De25<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f18\u5148\u63a8\u8350De32<\/strong>\uff0c\u786e\u4fdd\u5927\u6d41\u91cf\uff0c\u907f\u514d\u540e\u671f\u52a0\u6cf5\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&gt; 200\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">De40\u6216\u66f4\u5927<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u8fdb\u884c\u7cbe\u786e\u6c34\u529b\u8ba1\u7b97\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\"><strong>3. \u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c\u7ba1\u5f84\u5efa\u8bae\uff1a<\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">\u51b7\u51dd\u7089\u4f4e\u6e29\uff08\u226455\u2103\uff09\u9ad8\u6548\u8fd0\u884c\u5bf9\u7ba1\u8def\u7ba1\u5f84\u8981\u6c42\u66f4\u9ad8\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ba1\u5f84\u7ec4\u5408<\/th><th>\u7279\u70b9<\/th><th>\u6548\u679c<\/th><th>\u9002\u7528\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td>De32\u4e3b\u7ba1 + De20\u76d8\u7ba1<\/td><td>\u6d41\u91cf\u5145\u8db3\uff0c\u7cfb\u7edf\u963b\u529b\u5c0f<\/td><td>\u4f4e\u6e29\u5927\u6d41\u91cf\u8fd0\u884c\uff0c\u672b\u7aef\u70ed\u91cf\u5206\u914d\u5747\u5300\uff0c\u7efc\u5408\u8282\u80fd\u6548\u679c\u660e\u663e<\/td><td>\u4e2d\u5927\u9762\u79ef\u5730\u6696\u7cfb\u7edf\uff08\u63a8\u8350\uff09<\/td><\/tr><tr><td>De25\u4e3b\u7ba1 + De16\u76d8\u7ba1<\/td><td>\u6d41\u91cf\u53d7\u9650\uff0c\u7cfb\u7edf\u963b\u529b\u5927<\/td><td>\u4f4e\u6e29\u8fd0\u884c\u65f6\u8fdc\u7aef\u652f\u8def\u6d41\u91cf\u53ef\u80fd\u4e0d\u8db3\u2192\u672b\u7aef\u4e0d\u70ed\u2192\u9505\u7089\u88ab\u8feb\u63d0\u9ad8\u6c34\u6e29\u2192\u9ad8\u80fd\u8017\u5faa\u73af<\/td><td>\u4ec5\u9002\u540830\u33a1\u4ee5\u4e0b\u5fae\u578b\u7cfb\u7edf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u7ba1\u5f84\u9009\u578b\u4f9d\u636e JGJ 142-2012 \u4e2d\u5173\u4e8e\u6c34\u529b\u8ba1\u7b97\u548c\u6d41\u91cf\u5206\u914d\u7684\u8bbe\u8ba1\u8981\u6c42\u3002<\/p>\n<\/blockquote>\n\n<h5 class=\"wp-block-heading\">4. <strong>\u7a7a\u6c14\u80fd\u5730\u6696\u4f4e\u6e29\u8fd0\u884c\u7ba1\u5f84\u5efa\u8bae<\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">\u7a7a\u6c14\u80fd\uff08\u70ed\u6cf5\uff09\u5730\u6696\u7cfb\u7edf\u662f\u5178\u578b\u7684\u4f4e\u6e29\u8fd0\u884c\u7cfb\u7edf\uff08\u4f9b\u6c34\u6e29\u5ea6\u901a\u5e38\u4e3a35-45\u2103\uff09\uff0c\u5176\u9ad8\u6548\u8fd0\u884c\u5bf9\u7ba1\u8def\u7ba1\u5f84\u7684\u8981\u6c42<strong>\u6781\u5176\u4e25\u683c<\/strong>\u3002\u4e0e\u51b7\u51dd\u7089\u7cfb\u7edf\u4e0d\u540c\uff0c\u7a7a\u6c14\u80fd\u7cfb\u7edf\u7684\u7ba1\u5f84\u9009\u62e9\u4e0d\u4ec5\u5173\u4e4e\u80fd\u6548\uff0c\u66f4\u662f\u7cfb\u7edf\u80fd\u5426<strong>\u6b63\u5e38\u542f\u52a8\u548c\u7a33\u5b9a\u8fd0\u884c<\/strong>\u7684\u6027\u547d\u6538\u5173\u7684\u95ee\u9898\u3002<\/p>\n\n<h5 class=\"wp-block-heading\"><strong>\u6838\u5fc3\u539f\u5219\u4e0e\u8b66\u544a<\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u300a\u6c34\u5885\u9002\u6545\u969c\u4ee3\u7801.pdf\u300b\u548c\u300a\u5929\u6c1f\u5730\u6c34\u9879\u76ee\u5ba1\u56fe\u8d44\u6599\u8981\u6c42\u300b\u7b49\u591a\u4efd\u77e5\u8bc6\u5e93\u6587\u4ef6\uff0c\u7a7a\u6c14\u80fd\u7cfb\u7edf\u5bf9\u6c34\u6d41\u91cf\u6709<strong>\u786c\u6027\u6700\u4f4e\u8981\u6c42<\/strong>\u3002\u7ba1\u5f84\u8fc7\u5c0f\u5bfc\u81f4\u7cfb\u7edf\u963b\u529b\u8fc7\u5927\uff0c\u5faa\u73af\u6c34\u6d41\u91cf\u4f4e\u4e8e\u8bbe\u5907\u6700\u5c0f\u9700\u6c42\u65f6\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u76f4\u63a5\u540e\u679c<\/strong>\uff1a\u4e3b\u673a\u5c06\u7acb\u5373\u89e6\u53d1<strong>\u6c34\u6d41\u6545\u969c\u4ee3\u7801\uff08\u598206\u7cfb\u5217\u768476\u30017A\u621670\uff09<\/strong>\uff0c\u7cfb\u7edf\u81ea\u52a8\u505c\u673a\u4fdd\u62a4\uff0c\u65e0\u6cd5\u5236\u70ed\u6216\u5236\u51b7\u3002<\/li>\n\n<li><strong>\u884c\u4e1a\u73b0\u72b6<\/strong>\uff1a\u8fd9\u662f\u76ee\u524d\u5929\u6c1f\u5730\u6c34\u548c\u5929\u6c34\u5730\u6c34\u9879\u76ee\u65bd\u5de5\u4e2d\u6700\u5e38\u89c1\u3001\u4e5f\u662f\u6700\u96be\u4ee5\u6392\u67e5\u7684\u7cfb\u7edf\u6027\u95ee\u9898\u3002\u65bd\u5de5\u65b9\u4e3a\u8282\u7701\u6210\u672c\u4f7f\u7528\u8fc7\u5c0f\u7ba1\u5f84\uff0c\u5bfc\u81f4\u8bbe\u5907\u65e0\u6cd5\u8fd0\u8f6c\uff0c\u6700\u540e\u53cd\u800c\u5f52\u548e\u4e8e\u5382\u5bb6\u8bbe\u5907\u8d28\u91cf\u95ee\u9898\u3002\u8fd9\u5c5e\u4e8e\u5178\u578b\u7684\u201c<strong>\u53a8\u5e08\u602a\u5200\u949d<\/strong>\u201d\u2014\u2014\u65bd\u5de5\u8bbe\u8ba1\u7f3a\u9677\u800c\u975e\u8bbe\u5907\u672c\u8eab\u6545\u969c\u3002<\/li>\n<\/ul>\n\n<h5 class=\"wp-block-heading\"><strong>\u7a7a\u6c14\u80fd\u5730\u6696\u7ba1\u5f84\u9009\u578b\u5efa\u8bae<\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">\u77e5\u8bc6\u5e93\u4e2d\u201c\u65e5\u7acb\u54c1\u724c\u8bbe\u8ba1\u6307\u5bfc\u4e66\u201d\u53ca\u6280\u672f\u901a\u77e5\u660e\u786e\u6307\u51fa\uff0c\u6807\u51c6\u63a8\u8350<strong>\u4e3b\u7ba1\u91c7\u7528PPR\u7ba1S5\u7cfb\u5217<\/strong>\uff08\u9f99\u8109\u6696\u901a\u5efa\u8baePPR\u91c7\u7528S3.2\uff0c\u6216FPPRCT\u7a7a\u8c03\u6c34\u7cfb\u7edf\u4e13\u7528\u7ba1S5\u7cfb\u5217\uff09\uff0c\u5e76\u5efa\u8bae\u5728\u6761\u4ef6\u5141\u8bb8\u4e0b<strong>\u52a0\u5927\u7ba1\u5f84<\/strong>\u4ee5\u4fdd\u969c\u6d41\u91cf\u3002\u4ee5\u4e0b\u662f\u4e25\u683c\u9075\u5faa\u77e5\u8bc6\u5e93\u7684\u9009\u578b\u5efa\u8bae\uff1a<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u5f84\u7ec4\u5408<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6548\u679c\u4e0e\u98ce\u9669<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f\u4e0e\u7ed3\u8bba<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De50\u4e3b\u7ba1 + De20\u76d8\u7ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d41\u91cf\u6781\u5176\u5145\u8db3\uff0c\u7cfb\u7edf\u963b\u529b\u6781\u4f4e<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53ef\u5b89\u5168\u8986\u76d6\u5927\u9762\u79ef\u533a\u57df<\/strong>\uff0c\u7cfb\u7edf\u6781\u5176\u7a33\u5b9a\uff0c\u80fd\u5b8c\u5168\u6ee1\u8db3\u7a7a\u6c14\u80fd\u4f4e\u6e29\u5927\u6d41\u91cf\u7684\u786c\u6027\u8981\u6c42\uff0c\u5b8c\u7f8e\u907f\u514d\u201c\u62c9\u4e0d\u52a8\u201d\u5bfc\u81f4\u7684\u62a5\u6545\u969c\u98ce\u9669\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u522b\u5885\u3001\u5927\u9762\u79ef\u4f4f\u5b85\uff08\u2265150\u33a1\uff09\u7684\u63a8\u8350\u6216\u9996\u9009\u65b9\u6848\u3002<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De40\u4e3b\u7ba1 + De20\u76d8\u7ba1<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d41\u91cf\u5145\u8db3\uff0c\u7cfb\u7edf\u963b\u529b\u8f83\u5c0f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u5e38\u89c4\u4e2d\u5927\u6237\u578b\uff08\u5982\u2264120\u33a1\uff09\uff0c\u5728<strong>\u4e3b\u7ba1\u603b\u957f\u5ea6\u4e0d\u957f<\/strong>\uff08\u5982\u226480\u7c73\uff09\u7684\u60c5\u51b5\u4e0b\u53ef\u6ee1\u8db3\u6d41\u91cf\u9700\u6c42\u3002\u4f46\u4ecd\u9700\u8fdb\u884c\u4e25\u683c\u6c34\u529b\u8ba1\u7b97\uff0c\u786e\u4fdd\u6bd4\u6469\u963b\u5728\u89c4\u8303\u503c\u5185\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u5e38\u89c4\u4e2d\u5927\u6237\u578b\uff08100-150\u33a1\uff09\uff0c\u4f46\u5fc5\u987b\u7ecf\u8fc7\u6c34\u529b\u6821\u6838\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De25\u4e3b\u7ba1 + De16\u76d8\u7ba1\uff08\u4e25\u7981\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6d41\u91cf\u4e25\u91cd\u53d7\u9650\uff0c\u7cfb\u7edf\u963b\u529b\u6781\u5927<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>200%\u65e0\u6cd5\u6ee1\u8db3\u7a7a\u6c14\u80fd\u7cfb\u7edf\u7684\u6700\u5c0f\u6d41\u91cf\u9700\u6c42\u3002<\/strong> \u8fdc\u7aef\u672b\u7aef\u5c06\u4e25\u91cd\u4e0d\u70ed\uff0c\u5e76<strong>\u76f4\u63a5\u89e6\u53d1\u6c34\u6d41\u6545\u969c\u4ee3\u7801<\/strong>\uff0c\u5bfc\u81f4\u4e3b\u673a\u9891\u7e41\u542f\u505c\u6216\u76f4\u63a5\u505c\u673a\uff0c\u7cfb\u7edf\u65e0\u6cd5\u6b63\u5e38\u8fd0\u884c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e25\u7981\u7528\u4e8e\u4efb\u4f55\u7a7a\u6c14\u80fd\u7cfb\u7edf\u3002<\/strong> \u884c\u4e1a\u901a\u75c5\uff0c\u5fc5\u51fa\u95ee\u9898\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u9009\u578b\u4f9d\u636e\uff1a<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u300a\u65e5\u7acb\u54c1\u724c(\u5bb6\u4e2d\u677f\u5757)\u8bbe\u8ba1\u6307\u5bfc\u4e66(\u4e0a).pdf\u300b<\/strong>\uff1a\u660e\u786e\u8981\u6c42\u4f9b\u56de\u6c34\u4e3b\u7ba1\u91c7\u7528<strong>PPR\u7ba1\uff0c\u63a8\u8350S5\u7cfb\u5217<\/strong>\uff0c\u5e76\u7ed9\u51fa\u4e0d\u540c\u7ba1\u5f84\u5bf9\u5e94\u7684\u6d41\u91cf\u548c\u70ed\u8d1f\u8377\u8303\u56f4\u3002<\/li>\n\n<li><strong>\u300aHH-CD-TZ-JS0001-\u5173\u4e8e\u5929\u6c1f\u5730\u6c34\u9879\u76ee\u5ba1\u56fe\u8d44\u6599\u63d0\u4ea4\u8981\u6c42\u53ca\u6c34\u8def\u4e3b\u7ba1\u9009\u578b\u8981\u6c42.pdf\u300b<\/strong>\uff1a\u660e\u786e\u8b66\u544a\uff0c\u7531\u4e8e\u7ba1\u5f84\u8fc7\u5c0f\u9020\u6210\u6c34\u6d41\u91cf\u4e0d\u8db3\uff0c\u7cfb\u7edf\u62a5\u6c34\u6d41\u6545\u969c\uff1b\u5e76\u63d0\u4f9b\u8be6\u7ec6\u7684\u9009\u578b\u8868\u683c\u4e0e\u6c34\u6cf5\u6821\u6838\u65b9\u6cd5\u3002<\/li>\n\n<li><strong>\u300a\u6c34\u5885\u9002\u6545\u969c\u4ee3\u7801.pdf\u300b<\/strong>\uff1a\u6307\u660e<strong>7A\uff08\u6c34\u538b\u8fc7\u4f4e\u6216\u6c34\u6d41\u91cf\u8fc7\u5c0f\uff09<\/strong> \u548c<strong>76\uff08\u6db2\u7ba1\u51bb\u7ed3\uff09<\/strong> \u7b49\u76f4\u63a5\u7531\u6c34\u6d41\u91cf\u95ee\u9898\u5f15\u53d1\u7684\u6545\u969c\u4ee3\u7801\u3002<\/li>\n<\/ul>\n\n<h5 class=\"wp-block-heading\"><strong>\u7ba1\u5f84\u4e0d\u5339\u914d\u5f15\u53d1\u7684\u6838\u5fc3\u95ee\u9898\uff08\u4e25\u91cd\u7b49\u7ea7\u6392\u5e8f\uff09<\/strong><\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u4e25\u91cd\u7b49\u7ea7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5177\u4f53\u8868\u73b0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u7a7a\u6c14\u80fd\u7cfb\u7edf\u7684\u6700\u7ec8\u5f71\u54cd<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u2160\u7ea7\uff08\u81f4\u547d\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6d41\u91cf\u4e0d\u8db3\uff0c\u7cfb\u7edf\u9501\u673a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u963b\u529b\u8fc7\u5927\uff0c\u6c34\u6d41\u65e0\u6cd5\u6ee1\u8db3\u8bbe\u5907\u6700\u4f4e\u9700\u6c42\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u673a\u76f4\u63a5\u62a5\u6545\u969c\u4ee3\u7801\uff08\u59827A\/76\/70\uff09\uff0c\u505c\u6b62\u5de5\u4f5c\uff0c\u65e0\u6cd5\u5236\u70ed\u3002<\/strong> \u8fd9\u662f\u751f\u6b7b\u7ebf\u95ee\u9898\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u2161\u7ea7\uff08\u91cd\u5927\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u80fd\u6548\u6bd4\uff08COP\uff09\u4e25\u91cd\u4e0b\u964d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52c9\u5f3a\u5f00\u673a\u540e\uff0c\u56e0\u6d41\u91cf\u4e0d\u8db3\u88ab\u8feb\u63d0\u9ad8\u51fa\u6c34\u6e29\u5ea6\uff0c\u5bfc\u81f4\u70ed\u6cf5\u6548\u7387\u5927\u5e45\u964d\u4f4e\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8fd0\u884c\u8d39\u7528\u98d9\u534730%-50%<\/strong>\uff0c\u4e27\u5931\u8282\u80fd\u4f18\u52bf\uff0c\u7528\u6237\u201c\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77\u201d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u2162\u7ea7\uff08\u7cfb\u7edf\u635f\u5bb3\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u529b\u4e25\u91cd\u5931\u8861\u4e0e\u8bbe\u5907\u635f\u8017<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd1\u7aef\u8fc7\u70ed\u3001\u8fdc\u7aef\u4e0d\u70ed\uff1b\u6c34\u6cf5\u957f\u671f\u9ad8\u8d1f\u8377\u8fd0\u8f6c\uff0c\u566a\u97f3\u5927\u3001\u5bff\u547d\u7f29\u77ed\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u65e0\u6cd5\u6b63\u5e38\u8fd0\u884c\uff0c\u53ef\u80fd\u5bfc\u81f4\u6c34\u6cf5\u3001\u6362\u70ed\u5668\u7b49\u90e8\u4ef6\u8fc7\u65e9\u635f\u574f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">4.1.3 \u6c34\u529b\u5e73\u8861\uff08\u540c\u7a0b\/\u7ae0\u9c7c\u5f0f vs \u5f02\u7a0b\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\">\u6c34\u529b\u5e73\u8861\u662f\u89e3\u51b3\u201c\u8fd1\u7aef\u70ed\u3001\u8fdc\u7aef\u51c9\u201d\u8fd9\u4e00\u6838\u5fc3\u75db\u70b9\u7684\u5173\u952e\u3002\u5b83\u786e\u4fdd\u6bcf\u4e2a\u56de\u8def\u90fd\u80fd\u83b7\u5f97\u8db3\u591f\u6d41\u91cf\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8fde\u63a5\u65b9\u5f0f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u539f\u7406<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f02\u7a0b\u5f0f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5404\u56de\u8def\u7ba1\u9053\u957f\u5ea6\u4e0d\u540c\uff0c\u6c34\u5148\u53bb\u8fd1\u7aef\uff0c\u518d\u53bb\u8fdc\u7aef\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7f3a\u70b9\u660e\u663e<\/strong>\uff1a\u8fd1\u7aef\u6d41\u91cf\u5927\uff0c\u8fdc\u7aef\u6d41\u91cf\u5c0f\uff0c\u6781\u6613\u51fa\u73b0\u201c\u8fd1\u70ed\u8fdc\u51b7\u201d\uff0c\u662f90%\u4e0d\u70ed\u95ee\u9898\u7684\u6839\u6e90\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9884\u7b97\u6781\u4f4e\u3001\u5bf9\u6548\u679c\u8981\u6c42\u4e0d\u9ad8\u7684\u5de5\u7a0b\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u540c\u7a0b\u5f0f\uff08\u63a8\u8350\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u4e2a\u56de\u8def\u7684\u4f9b\u6c34\u3001\u56de\u6c34\u7ba1\u8def\u603b\u957f\u5ea6\u57fa\u672c\u76f8\u7b49\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u529b\u5e73\u8861\u597d<\/strong>\uff1a\u5404\u56de\u8def\u963b\u529b\u76f8\u7b49\uff0c\u6d41\u91cf\u5206\u914d\u5747\u5300\uff0c\u6548\u679c\u7a33\u5b9a\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5927\u6237\u578b\u3001\u522b\u5885<\/strong>\u3001\u6696\u6c14\u7247\u7cfb\u7edf\u7684\u7406\u60f3\u9009\u62e9\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ae0\u9c7c\u5f0f\uff08\u5206\u96c6\u6c34\u5668\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ece\u5206\u96c6\u6c34\u5668\u76f4\u63a5\u5f15\u4e00\u6761\u72ec\u7acb\u7ba1\u9053\u5230\u672b\u7aef\uff0c\u5f62\u6210\u201c\u661f\u5f62\u201d\u7ed3\u6784\uff0c\u5404\u652f\u8def\u72ec\u7acb\u63a7\u5236\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u529b\u5e73\u8861\u6700\u4f18<\/strong>\uff1a\u5404\u56de\u8def\u4e92\u4e0d\u5e72\u6270\uff0c\u8c03\u8282\u65b9\u4fbf\uff0c\u662f<strong>\u4e13\u4e1a\u5730\u6696\u7cfb\u7edf\u7684\u6807\u51c6\u505a\u6cd5<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6240\u6709\u5730\u6696\u7cfb\u7edf<\/strong>\uff0c\u5c24\u5176\u662f\u5bf9\u5404\u623f\u95f4\u6e29\u5dee\u6709\u4e25\u683c\u8981\u6c42\u7684\u573a\u666f\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a<strong>\u575a\u6301\u91c7\u7528\u7ae0\u9c7c\u5f0f\u6216\u540c\u7a0b\u5f0f<\/strong>\uff0c\u907f\u514d\u4f7f\u7528\u5f02\u7a0b\u5f0f\u3002\u8fd9\u662f\u786e\u4fdd\u201c\u6bcf\u4e2a\u623f\u95f4\u90fd\u70ed\u201d\u7684\u6700\u6839\u672c\u8bbe\u8ba1\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">4.1.4 \u8f85\u6750\u6df1\u5ea6\u89e3\u6790<\/h4>\n\n<p class=\"wp-block-paragraph\">\u8f85\u6750\u867d\u5c0f\uff0c\u5374\u76f4\u63a5\u51b3\u5b9a\u4e86\u7cfb\u7edf\u7684\u957f\u671f\u4fdd\u6e29\u6548\u679c\u3001\u8282\u80fd\u6027\u548c\u7cfb\u7edf\u5bff\u547d\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>1. \u4fdd\u6e29\u677f<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u6324\u5851\u677f (XPS) - \u9ed8\u8ba4<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u767d\u6676\u677f - \u53ef\u9009<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4ee3\u8868\u54c1\u724c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bfa\u5c14<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f1f\u661f \/ \u7eff\u7fbd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6838\u5fc3\u6750\u8d28<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6324\u5851\u805a\u82ef\u4e59\u70ef<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u54c1\u8d28\u805a\u82ef\u4e59\u70ef\uff08\u7eaf\u5ea6\u66f4\u9ad8\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u8981\u4f18\u52bf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ef7\u683c\u7ecf\u6d4e\u5b9e\u60e0\uff0c\u6ee1\u8db3\u57fa\u672c\u4fdd\u6e29\u9700\u6c42<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u6e29\u6027\u80fd\u66f4\u4f18\u3001\u66f4\u73af\u4fdd\uff08\u4f4eVOC\uff09\u3001\u6297\u538b\u5f3a\u5ea6\u66f4\u9ad8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u539a\u5ea6\u89c4\u683c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">2cm (20mm)<\/td><td class=\"has-text-align-left\" data-align=\"left\">2cm (20mm)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7eff\u7fbd\u4e0e\u4f1f\u661f\u767d\u6676\u677f\uff08\u5ba2\u89c2\u68c0\u6d4b\u6570\u636e\u5bf9\u6bd4\uff09<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u300a\u4f1f\u661f\u548c\u7eff\u7fbd\u73af\u4fdd\u767d\u6676\u677f\u62a5\u544a\u5bf9\u6bd4\u5206\u6790.pdf\u300b\u3001\u300a\u7eff\u7fbd1_\u73af\u4fdd\u767d\u6676\u677f.pdf\u300b\u3001\u300a\u4f1f\u661fXPS\u5730\u6696\u4fdd\u6e29\u677f\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a.pdf\u300b\uff0c\u4e24\u5bb6\u54c1\u724c\u7684\u767d\u6676\u677f\u5747\u901a\u8fc7\u4e86\u6743\u5a01\u673a\u6784\u68c0\u6d4b\uff0c\u7b26\u5408\u56fd\u6807\u8981\u6c42\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u68c0\u6d4b\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7eff\u7fbd\u73af\u4fdd\u767d\u6676\u677f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f1f\u661fXPS\u5730\u6696\u4fdd\u6e29\u677f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5206\u6790\u4e0e\u5efa\u8bae<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7532\u919b\u91ca\u653e\u91cf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.021 mg\/m\u00b3 (\u5b9e\u6d4b)<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u672a\u68c0\u51fa (N.D.)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7eff\u7fbd\u6709\u5fae\u91cf\u68c0\u51fa\u4f46\u6570\u503c\u6781\u4f4e\uff0c\u7b26\u5408\u5065\u5eb7\u8981\u6c42\u3002\u4f1f\u661f\u201c\u672a\u68c0\u51fa\u201d\u66f4\u4e3a\u5f7b\u5e95\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>TVOC\u91ca\u653e\u91cf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.311 mg\/m\u00b3 (\u5b9e\u6d4b)<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u672a\u68c0\u51fa (N.D.)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f1f\u661f\u201c\u53cc\u672a\u68c0\u51fa\u201d\u5728\u5ba4\u5185\u7a7a\u6c14\u54c1\u8d28\u8981\u6c42\u9ad8\u7684\u9879\u76ee\u4e2d\u66f4\u5177\u8bf4\u670d\u529b\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u538b\u7f29\u5f3a\u5ea6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>364 kPa<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2265200 kPa\uff08\u53c2\u8003\u503c\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7eff\u7fbd\u8868\u73b0\u66f4\u4f18<\/strong>\uff0c\u5728\u627f\u91cd\u533a\u57df\u66f4\u4e0d\u6613\u53d8\u5f62\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5438\u6c34\u7387 \uff08\u4f53\u79ef\u5206\u6570\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>0.4%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672a\u63d0\u4f9b\u5177\u4f53\u6570\u503c<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7eff\u7fbd\u8868\u73b0\u66f4\u4f18<\/strong>\uff0c\u5728\u6f6e\u6e7f\u73af\u5883\u4e2d\u4fdd\u6e29\u6027\u80fd\u66f4\u7a33\u5b9a\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5bfc\u70ed\u7cfb\u6570<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.034 W\/(m\u00b7K)<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>0.031 W\/(m\u00b7K)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f1f\u661f\u8868\u73b0\u66f4\u4f18<\/strong>\uff0c\u4fdd\u6e29\u6027\u80fd\u7a0d\u597d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5c3a\u5bf8\u7a33\u5b9a\u6027<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6570\u636e\u4f18\u5f02<\/strong>\uff08\u957f\u5ea60.2%\/\u5bbd\u5ea60.2%\/\u539a\u5ea60.3%\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672a\u63d0\u4f9b\u5177\u4f53\u6570\u503c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7eff\u7fbd\u957f\u671f\u53d7\u70ed\u540e\u53d8\u5f62\u5c0f\uff0c\u6027\u80fd\u7a33\u5b9a\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u5ba2\u89c2\u5efa\u8bae\uff08\u4ec5\u4f9b\u7528\u6237\u53c2\u8003\uff0c\u4e0d\u505a\u63a8\u8350\uff09<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7eff\u7fbd\u767d\u6676\u677f<\/strong>\uff1a\u6709\u5b8c\u6574\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a\uff0c\u6570\u636e\u5168\u9762\uff08\u73af\u4fdd\u3001\u7edd\u70ed\u3001\u8010\u6c34\u3001\u5c3a\u5bf8\u7a33\u5b9a\u6027\u5747\u4f18\uff09\u3002<\/li>\n\n<li><strong>\u4f1f\u661f\u767d\u6676\u677f<\/strong>\uff1a\u77e5\u8bc6\u5e93\u786e\u8ba4\u5176<strong>\u4ec5\u4f9b\u5e942cm\u539a\u5ea6<\/strong>\uff0c\u68c0\u6d4b\u6570\u636e\u672a\u663e\u793a\u3002\u65b9\u6848\u4e2d\u5982\u97003cm\u539a\u5ea6\uff0c\u9700\u8003\u8651\u66ff\u4ee3\u54c1\u724c\uff08\u5982\u8bfa\u5c14\uff09\u3002<\/li>\n\n<li><strong>\u6838\u5fc3\u884c\u52a8\u70b9<\/strong>\uff1a\u5efa\u8bae\u5411\u5ba2\u6237\u63d0\u4f9b<strong>\u7eff\u7fbd\u767d\u6676\u677f\u7684\u5b8c\u6574\u68c0\u6d4b\u62a5\u544a<\/strong>\uff0c\u7528\u6570\u636e\u8bf4\u8bdd\uff0c\u65e2\u4e13\u4e1a\u53c8\u964d\u4f4e\u98ce\u9669\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>2. \u53cd\u5c04\u819c<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u955c\u9762\u9540\u94dd\u819c<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5168\u94dd\u53cd\u5c04\u819c - \u63a8\u8350<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ed3\u6784<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5728PET\u8584\u819c\u4e0a\u9540\u4e00\u5c42\u6781\u8584\u94dd\u5c42<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7eaf\u94dd\u7b94\u5c42\uff08\u6709\u4e00\u5b9a\u539a\u5ea6\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u521d\u59cb\u53cd\u5c04\u7387<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt;95%\uff08\u65b0\u819c\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt;95%\uff08\u65b0\u819c\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8010\u8150\u8680\u6027<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u2b50 \u94dd\u5c42\u6781\u8584\uff0c\u6613\u88ab\u6c34\u6ce5\u78b1\u6027\u8150\u8680\u8131\u843d\uff0c\u53cd\u5c04\u7387\u65ad\u5d16\u5f0f\u4e0b\u964d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2b50\u2b50\u2b50\u2b50\u2b50 \u7eaf\u94dd\u5c42\u6709\u4e00\u5b9a\u539a\u5ea6\uff0c\u8868\u9762\u6c27\u5316\u5f62\u6210\u4fdd\u62a4\u819c\uff08\u521a\u7389\uff09\u4fdd\u62a4\u5e95\u5c42\uff0c\u53cd\u5c04\u6027\u80fd\u6301\u4e45<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u957f\u671f\u7a33\u5b9a\u6027<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5dee<\/strong>\uff08\u6027\u80fd\u8870\u51cf\u5feb\uff0c\u5bff\u547d\u77ed\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f18<\/strong>\uff08\u6027\u80fd\u7a33\u5b9a\uff0c\u4e0e\u5730\u6696\u7cfb\u7edf\u540c\u5bff\u547d\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u9632\u6b62\u201c\u4e0d\u8d77\u4f5c\u7528\u201d\u8bef\u533a\u7684\u6b63\u786e\u8ba4\u77e5<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u8bef\u533a<\/strong>\uff1a\u201c\u53cd\u5c04\u819c\u88ab\u56de\u586b\u5c42\u76d6\u4f4f\u4e86\uff0c\u50cf\u5e03\u76d6\u4f4f\u955c\u5b50\u4e00\u6837\uff0c\u8d77\u4e0d\u5230\u53cd\u5c04\u4f5c\u7528\u4e86\u3002\u201d<\/li>\n\n<li><strong>\u771f\u76f8<\/strong>\uff1a\u70ed\u8f90\u5c04\u662f\u7535\u78c1\u6ce2\uff0c\u53ef\u4ee5\u7a7f\u900f\u4e00\u5b9a\u539a\u5ea6\u7684\u6c34\u6ce5\u7802\u6d46\u3002\u53cd\u5c04\u819c\u7684\u4f5c\u7528\u662f<strong>\u5c06\u5411\u4e0b\u8f90\u5c04\u7684\u70ed\u91cf\u201c\u9501\u201d\u56de\u56de\u586b\u5c42<\/strong>\uff0c\u8ba9\u56de\u586b\u5c42\u8fd9\u4e2a\u201c\u84c4\u70ed\u4f53\u201d\u66f4\u9ad8\u6548\u5730\u50a8\u5b58\u548c\u5747\u5300\u91ca\u653e\u70ed\u91cf\u3002<\/li>\n\n<li><strong>\u9009\u578b\u5efa\u8bae<\/strong>\uff1a<strong>\u575a\u51b3\u9009\u7528\u9ad8\u53cd\u5c04\u7387\uff08&gt;95%\uff09\u7684\u5168\u94dd\u53cd\u5c04\u819c<\/strong>\uff0c\u907f\u514d\u9009\u7528\u201c\u955c\u9762\u9540\u94dd\u819c\u201d\u7b49\u957f\u671f\u53cd\u5c04\u6027\u80fd\u65e0\u6cd5\u4fdd\u8bc1\u7684\u4ea7\u54c1\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>3. \u5176\u4ed6\u8f85\u6750<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u8fb9\u89d2\u4fdd\u6e29\u6761<\/strong>\uff1a\u9ad8\u53d1\u6ce1\u805a\u4e59\u70ef\uff0c\u539a\u5ea6\u226510mm\uff0c\u9632\u6b62\u70ed\u91cf\u6cbf\u5899\u4f53\u6563\u5931\u3002<strong>\u5fc5\u987b\u94fa\u8bbe<\/strong>\u3002<\/li>\n\n<li><strong>\u5361\u9489<\/strong>\uff1a\u7528\u4e8e\u56fa\u5b9a\u5730\u6696\u76d8\u7ba1\uff0c\u9700\u4f7f\u7528<strong>\u7eff\u8272\u73af\u4fdd\u5361\u9489<\/strong>\u3002<\/li>\n\n<li><strong>\u7845\u6676\u7f51<\/strong>\uff1a\u7528\u4e8e\u6e7f\u6cd5\u56de\u586b\u5c42\uff0c\u9632\u6b62\u5730\u9762\u5f00\u88c2\uff0c\u63d0\u5347\u6574\u4f53\u7ed3\u6784\u5f3a\u5ea6\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">4.1.5 \u6838\u5fc3\u914d\u4ef6\u4e0e\u6c34\u8d28\u8981\u6c42\uff1a\u7cfb\u7edf\u957f\u5bff\u7684\u9690\u5f62\u7ea2\u7ebf<\/h4>\n\n<p class=\"wp-block-paragraph\">\u7cfb\u7edf\u6c34\u8d28\u4e0d\u5408\u683c\uff0c\u662f\u5bfc\u81f4\u5730\u6696\u7cfb\u7edf\u201c\u9ed1\u6c34\u3001\u5f02\u5473\u3001\u8150\u8680\u6f0f\u6c34\u3001\u6548\u7387\u964d\u4f4e\u201d\u7684\u9690\u5f62\u6740\u624b\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e0d\u540c\u6750\u8d28\u7684\u6c34\u8d28\u8981\u6c42\uff08\u5f15\u7528\u81ea\u300a2009JSCS-4\u300b\uff09<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5907\/\u7ba1\u9053\u6750\u8d28<\/th><th class=\"has-text-align-left\" data-align=\"left\">pH\u503c\u8981\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6c2f\u79bb\u5b50(Cl\u207b)\u9650\u5236<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u94a2\u5236\u8bbe\u5907 (\u6563\u70ed\u5668)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>10.0 - 12.0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2264 <strong>300 mg\/L<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94a2\u5236\u6563\u70ed\u5668\u6700\u6613\u8150\u8680\uff0c\u5bf9\u6c34\u8d28\u8981\u6c42\u975e\u5e38\u4e25\u683c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u94dc\u5236\u8bbe\u5907 (\u9505\u7089\u6362\u70ed\u5668)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>9.0 - 10.0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2264 <strong>100 mg\/L<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dc\u5236\u6362\u70ed\u5668\u8150\u8680\u6027\u76f8\u5bf9\u597d\uff0c\u4f46\u6c2f\u79bb\u5b50\u9ad8\u4ecd\u4f1a\u52a0\u901f\u8150\u8680<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u94dd\u5236\u8bbe\u5907 (\u7a7a\u6c14\u80fd\u6362\u70ed\u677f)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>8.5 - 9.0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2264 <strong>30 mg\/L<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94dd\u5236\u6362\u70ed\u5668\u5bf9\u6c2f\u79bb\u5b50\u6781\u5ea6\u654f\u611f\uff0c\u6c34\u8d28\u8981\u6c42\u6700\u9ad8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u5efa\u8bae\u63aa\u65bd<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u65b0\u623f\/\u9996\u6b21\u6ce8\u6c34<\/strong>\uff1a\u5efa\u8bae\u59d4\u6258\u4e13\u4e1a\u516c\u53f8\u5bf9\u7cfb\u7edf\u7528\u6c34\u8fdb\u884c\u521d\u6b65\u68c0\u6d4b\u3002\u5982\u679c\u6c34\u8d28\u786c\u5ea6\u8f83\u9ad8\uff0c\u5efa\u8bae\u52a0\u88c5<strong>\u8f6f\u6c34\u88c5\u7f6e<\/strong>\uff0c\u5e76<strong>\u9996\u6b21\u6ce8\u6c34\u6dfb\u52a0\u4fdd\u62a4\u5242<\/strong>\uff08\u5982F1\u4fdd\u62a4\u5242\uff09\u3002<\/li>\n\n<li><strong>\u5b9a\u671f\u68c0\u67e5<\/strong>\uff1a\u6bcf2-3\u5e74\u68c0\u67e5\u4e00\u6b21\u7cfb\u7edf\u6c34\u8d28\uff0c\u89c2\u5bdf\u6709\u65e0\u9ed1\u6c34\u3001\u5f02\u5473\u3002\u5982\u53d1\u73b0\u7ba1\u9053\u6709\u94c1\u9508\u8272\u6216\u6c34\u5448\u9178\u6027\uff0c\u5e94\u53ca\u65f6\u6dfb\u52a0\u4fdd\u62a4\u5242\u5e76\u8fdb\u884c\u6e05\u6d17\u3002<\/li>\n\n<li><strong>\u963b\u6c27\u662f\u5173\u952e<\/strong>\uff1a<strong>\u4e0e\u94a2\u5236\u6563\u70ed\u5668\u8054\u5408\u4f9b\u6696\u65f6\uff0c\u5fc5\u987b\u91c7\u7528\u94dd\u5851\u590d\u5408\u7ba1\u6216\u5e26\u963b\u6c27\u5c42\uff08EVOH\uff09\u7684\u70ed\u5851\u6027\u5851\u6599\u7ba1\u6750<\/strong>\u3002\u8fd9\u662f\u7cfb\u7edf\u5b89\u5168\u5bff\u547d\u7684\u5e95\u7ebf\u3002<\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">4.2 \u672b\u7aef\u7cfb\u7edf<\/h3>\n\n<p class=\"wp-block-paragraph\">\u672b\u7aef\u662f\u70ed\u91cf\u91ca\u653e\u5230\u623f\u95f4\u7684\u5730\u65b9\uff0c\u5305\u62ec\u5730\u6696\u76d8\u7ba1\u548c\u6696\u6c14\u7247\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">4.2.1 \u5730\u6696\u76d8\u7ba1\u4e0e\u6563\u70ed\u5f62\u5f0f<\/h4>\n\n<h5 class=\"wp-block-heading\"><strong>1. \u76d8\u7ba1\u89c4\u683c\u9009\u62e9<\/strong><\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u5f84<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5e94\u7528\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u56de\u8def\u6700\u5927\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u56de\u8def\u6700\u5927\u957f\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u6027<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De16 (\u5e38\u7528)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">100\u33a1\u4ee5\u4e0b\u4e2d\u5c0f\u6237\u578b<\/td><td class=\"has-text-align-left\" data-align=\"left\">10-15\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">80-100m<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6027\u4ef7\u6bd4\u9ad8\uff0c\u65bd\u5de5\u65b9\u4fbf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>De20 (\u63a8\u8350)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">100\u33a1\u4ee5\u4e0a\u5927\u6237\u578b\u3001\u522b\u5885<\/td><td class=\"has-text-align-left\" data-align=\"left\">15-20\u33a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">120-150m<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5927\u6d41\u91cf\u3001\u5c0f\u6e29\u5dee<\/strong>\uff0c\u7cfb\u7edf\u66f4\u7a33\u5b9a\uff0c\u53ef\u51cf\u5c11\u56de\u8def\u6570<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\"><strong>\u95f4\u8ddd\u3001\u5bc6\u5ea6\u4e0e\u56de\u8def\u7684\u5173\u7cfb\uff08\u5982\u4f55\u7406\u89e3\uff09<\/strong><\/h5>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u4e3b\u8981\u901a\u8fc7\u201c<strong>\u623f\u95f4\u70ed\u8d1f\u8377<\/strong>\u201d\u548c\u201c<strong>\u6bcf\u56de\u8def\u8986\u76d6\u9762\u79ef<\/strong>\u201d\u8054\u7cfb\u8d77\u6765\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u903b\u8f91\u94fe\uff1a<\/strong><\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u8ba1\u7b97\u70ed\u8d1f\u8377<\/strong>\uff1a\u9996\u5148\u786e\u5b9a\u623f\u95f4\u603b\u70ed\u8d1f\u8377\uff08\u4f8b\u5982\uff0c\u4e00\u4e2a20\u33a1\u7684\u5367\u5ba4\uff0c\u70ed\u8d1f\u8377\u4e3a100W\/\u33a1\uff0c\u603b\u70ed\u8d1f\u8377 = 20\u33a1 \u00d7 100W\/\u33a1 = 2000W\uff09\u3002<\/li>\n\n<li><strong>\u9009\u62e9\u7ba1\u5f84\u4e0e\u95f4\u8ddd<\/strong>\uff1a\u6839\u636e\u70ed\u8d1f\u8377\u548c\u89c4\u8303\uff0c\u9009\u5b9a\u7ba1\u5f84\uff08\u5982De16\uff09\u548c\u95f4\u8ddd\uff08\u5982120mm\uff09\u3002<\/li>\n\n<li><strong>\u4f30\u7b97\u5355\u56de\u8def\u6563\u70ed\u91cf\u4e0e\u8986\u76d6\u9762\u79ef<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u77e5\u8bc6\u70b9<\/strong>\uff1a\u540c\u4e00\u7cfb\u7edf\u4e0b\uff0c<strong>\u95f4\u8ddd\u8d8a\u5c0f<\/strong>\uff08\u8d8a\u5bc6\uff09\uff0c<strong>\u5355\u4f4d\u9762\u79ef\u6563\u70ed\u91cf\u8d8a\u5927<\/strong>\u3002<\/li>\n\n<li><strong>\u53c2\u8003\u6570\u636e<\/strong>\uff1a\u77e5\u8bc6\u5e93\u63d0\u4f9b\u201c\u6bcf\u56de\u8def\u8986\u76d6\u9762\u79ef\u7ea612-18\u33a1\u201d\uff0820\u7ba1\uff09\u7684\u4f30\u7b97\u503c\u3002\u5bf9\u4e8e16\u7ba1\uff0c\u7531\u4e8e\u5185\u5f84\u66f4\u5c0f\uff0c\u963b\u529b\u66f4\u5927\uff0c\u5176\u6709\u6548\u8986\u76d6\u9762\u79ef\u4f1a\u66f4\u5c0f\uff0c\u901a\u5e38\u5efa\u8bae\u4e0d\u8d85\u8fc712\u33a1\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u8ba1\u7b97\u56de\u8def\u6570<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u516c\u5f0f<\/strong>\uff1a<code>\u56de\u8def\u6570\u91cf = \u623f\u95f4\u70ed\u8d1f\u8377 \u00f7 \u5355\u8def\u70ed\u8f93\u51fa<\/code><\/li>\n\n<li><strong>\u7b80\u5316\u516c\u5f0f<\/strong>\uff1a<code>\u56de\u8def\u6570\u91cf \u2248 \u623f\u95f4\u9762\u79ef \u00f7 \u6bcf\u56de\u8def\u8986\u76d6\u9762\u79ef<\/code><\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\"><strong>\u793a\u4f8b<\/strong>\uff1a\u8fd8\u662f\u90a3\u4e2a20\u33a1\u7684\u5367\u5ba4\uff0c\u5982\u679c\u7528De16\u7ba1\uff0c\u8ba1\u5212\u95f4\u8ddd\u4e3a120mm\u3002<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u82e5\u6309\u7167\u6bcf\u56de\u8def\u6700\u4f73\u7ba1\u957f80-100\u7c73\uff0c\u65e0\u6cd5\u8986\u76d620\u33a1\u3002\u5fc5\u987b\u5c06\u623f\u95f4\u5206\u6210<strong>\u4e24\u4e2a\u56de\u8def<\/strong>\u3002\u4e14\uff1a\u603b\u56de\u8def\u76f8\u52a0\u6d41\u91cf\u2248\u4e3b\u7ba1\u6d41\u91cf\u3002<\/li>\n\n<li><strong>\u7ed3\u8bba<\/strong>\uff1a\u7ba1\u5f84\uff08De16\uff09\u9650\u5236\u4e86\u5355\u56de\u8def\u7684\u6700\u5927\u957f\u5ea6\u548c\u8986\u76d6\u9762\u79ef\uff0c\u5bfc\u81f4\u8fd9\u4e2a\u4e2d\u7b49\u9762\u79ef\u7684\u623f\u95f4\u4e5f\u9700\u89812\u4e2a\u56de\u8def\u624d\u80fd\u6ee1\u8db3\u70ed\u8d1f\u8377\u548c\u7ba1\u957f\u9650\u5236\u3002<\/li>\n<\/ul>\n\n<h5 class=\"wp-block-heading\"><strong>2. \u6563\u70ed\u5f62\u5f0f<\/strong><\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6563\u70ed\u5f62\u5f0f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u539f\u7406<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u8868<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8f90\u5c04\u6563\u70ed<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u901a\u8fc7\u7ea2\u5916\u7ebf\u76f4\u63a5\u52a0\u70ed\u4eba\u4f53\u548c\u7269\u4f53\u8868\u9762<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\uff08\u4f4e\u6e29\u8f90\u5c04\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8212\u9002\u5ea6\u9ad8\uff0c\u65e0\u98ce\u611f\uff0c\u6e29\u5ea6\u5206\u5e03\u5747\u5300<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u81ea\u7136\u5bf9\u6d41<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u70ed\u7a7a\u6c14\uff0c\u70ed\u7a7a\u6c14\u4e0a\u5347\u5f62\u6210\u5faa\u73af<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5347\u6e29\u5feb\uff0c\u53ef\u660e\u88c5\u6539\u9020<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f3a\u5236\u5bf9\u6d41<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u673a\u5f3a\u5236\u5e26\u52a8\u7a7a\u6c14\u6d41\u52a8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u98ce\u673a\u76d8\u7ba1\u3001\u7a7a\u8c03<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5347\u6e29\u6700\u5feb\uff0c\u53ef\u80fd\u6709\u98ce\u611f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\"><strong>3. \u76d8\u7ba1\u94fa\u8bbe\u6838\u5fc3\u53c2\u6570<\/strong><\/h5>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6807\u51c6<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u76d8\u7ba1\u95f4\u8ddd<\/td><td>15-20cm\uff08\u5e38\u89c4\u533a\u57df\uff09\uff1b10-15cm\uff08\u536b\u751f\u95f4\/\u9760\u5916\u5899\u533a\u57df\uff09<\/td><td>\u95f4\u8ddd\u8d8a\u5c0f\u6563\u70ed\u8d8a\u5927\uff0c\u4f46\u6210\u672c\u8d8a\u9ad8<\/td><\/tr><tr><td>\u5355\u56de\u8def\u6700\u5927\u957f\u5ea6<\/td><td>\u2264120m\uff08De16\u7ba1\uff09\uff1b\u2264150m\uff08De20\u7ba1\uff09<\/td><td>\u8fc7\u957f\u5bfc\u81f4\u6c34\u529b\u963b\u529b\u8fc7\u5927\uff0c\u672b\u7aef\u4e0d\u70ed<\/td><\/tr><tr><td>\u6bcf\u56de\u8def\u8986\u76d6\u9762\u79ef<\/td><td>\u7ea612-18\u33a1<\/td><td>\u4e00\u4e2a\u623f\u95f4\u53ef\u4e00\u4e2a\u56de\u8def\uff0c\u5927\u7a7a\u95f4\u9700\u591a\u56de\u8def\u5e76\u8054<\/td><\/tr><tr><td>\u76d8\u7ba1\u5f62\u5f0f<\/td><td>\u56de\u5b57\u5f62\uff08\u63a8\u8350\uff09\uff1eS\u5f62<\/td><td>\u56de\u5b57\u5f62\u9ad8\u6e29\u7ba1\u4e0e\u4f4e\u6e29\u7ba1\u95f4\u9694\u6392\u5217\uff0c\u5730\u9762\u6e29\u5ea6\u66f4\u5747\u5300<\/td><\/tr><tr><td>\u8ddd\u5899\u95f4\u8ddd<\/td><td>\u2265100mm<\/td><td>\u9632\u6b62\u70ed\u91cf\u6cbf\u5899\u4f53\u6563\u5931<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\"><strong>4. \u5730\u9762\u6750\u6599\u9009\u62e9\u2014\u2014\u76f4\u63a5\u5f71\u54cd\u91c7\u6696\u6548\u679c\uff1a<\/strong><\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5730\u9762\u6750\u6599<\/th><th>\u5bfc\u70ed\u6027\u80fd<\/th><th>\u63a8\u8350\u5ea6<\/th><th>\u6ce8\u610f\u4e8b\u9879<\/th><\/tr><\/thead><tbody><tr><td>\u74f7\u7816\/\u77f3\u6750<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u5bfc\u70ed\u7cfb\u6570\u6700\u9ad8<\/td><td>\u2605\u2605\u2605\u2605\u2605 \u9996\u9009<\/td><td>\u5347\u6e29\u6700\u5feb\uff0c\u70ed\u91cf\u635f\u8017\u6700\u5c0f<\/td><\/tr><tr><td>\u591a\u5c42\u5b9e\u6728\u590d\u5408\u5730\u677f<\/td><td>\u2605\u2605\u2605\u2605<\/td><td>\u2605\u2605\u2605\u2605 \u53ef\u9009<\/td><td>\u539a\u5ea6\u226415mm\uff0c\u7532\u919bE0\u6807\u51c6<\/td><\/tr><tr><td>\u5730\u6696\u4e13\u7528\u5f3a\u5316\u5730\u677f<\/td><td>\u2605\u2605\u2605\u2605<\/td><td>\u2605\u2605\u2605\u2605 \u53ef\u9009<\/td><td>\u9009\u7528\u5730\u6696\u4e13\u7528\u578b\uff0c\u6ce8\u610f\u73af\u4fdd\u7b49\u7ea7<\/td><\/tr><tr><td>\u5b9e\u6728\u5730\u677f<\/td><td>\u2605\u2605<\/td><td>\u2605\u2605 \u4e0d\u63a8\u8350<\/td><td>\u6613\u53d8\u5f62\u5f00\u88c2\u3001\u5bfc\u70ed\u5dee\uff08\u70ed\u963b\u5927\uff09<\/td><\/tr><tr><td>\u5730\u6bef<\/td><td>\u2605<\/td><td>\u2605 \u4e25\u7981\u94fa\u8bbe<\/td><td>\u963b\u788d\u70ed\u91cf\u4f20\u9012\uff0c\u964d\u4f4e\u80fd\u654830%\u4ee5\u4e0a<\/td><\/tr><tr><td>PVC\u5730\u677f<\/td><td>\u2605\u2605\u2605<\/td><td>\u2605\u2605 \u8c28\u614e<\/td><td>\u957f\u671f\u9ad8\u6e29\u53ef\u80fd\u91ca\u653e\u6709\u5bb3\u7269\u8d28<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\"><strong>5. \u56de\u586b\u5c42\uff08\u84c4\u70ed\u5c42\uff09\u8981\u6c42\uff1a<\/strong><\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u8981\u6c42<\/th><\/tr><\/thead><tbody><tr><td>\u56de\u586b\u6750\u6599<\/td><td>\u6c34\u6ce5\u7802\u6d46\uff08\u6c34\u6ce5:\u7802\u22481:2.5\uff09+ \u8c46\u77f3\uff08\u589e\u5f3a\u5bfc\u70ed\uff09<\/td><\/tr><tr><td>\u56de\u586b\u539a\u5ea6<\/td><td>\u226550mm\uff08\u8986\u76d6\u76d8\u7ba1\u4e0a\u8868\u9762\u226530mm\uff09<\/td><\/tr><tr><td>\u517b\u62a4\u5468\u671f<\/td><td>\u22657\u5929\uff08\u81ea\u7136\u517b\u62a4\uff0c\u4e0d\u53ef\u5f3a\u5236\u70d8\u5e72\uff09<\/td><\/tr><tr><td>\u4f5c\u7528<\/td><td>\u4fdd\u62a4\u76d8\u7ba1 + \u5747\u5300\u6563\u70ed + \u84c4\u70ed\u4fdd\u6e29\uff08\u5173\u673a\u540e\u4ecd\u6563\u70ed2-3\u5c0f\u65f6\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">4.2.2 \u56de\u586b\u5c42\u6df1\u5ea6\u89e3\u6790\uff08\u6e7f\u6cd5 vs \u5e72\u6cd5\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\">\u56de\u586b\u5c42\u662f\u5730\u6696\u7cfb\u7edf\u7684\u91cd\u8981\u7ec4\u6210\u90e8\u5206\uff0c\u5176\u201c\u84c4\u70ed\u5f0f\u201d\u4e0e\u201c\u5373\u70ed\u5f0f\u201d\u7684\u6839\u672c\u6027\u5dee\u5f02\uff0c\u5bf9\u7cfb\u7edf\u5339\u914d\u3001\u80fd\u8017\u548c\u8212\u9002\u5ea6\u6709\u6df1\u5ea6\u5f71\u54cd\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>1. \u6e7f\u6cd5\u56de\u586b\uff08\u4f20\u7edf\u5de5\u827a\uff09\uff1a\u84c4\u70ed\u5f0f\u7cfb\u7edf\u7684\u72ec\u7279\u4f18\u52bf<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7f13\u89e3\u529f\u7387\u4e0d\u5339\u914d\u95ee\u9898<\/strong>\uff1a\u77e5\u8bc6\u5e93\u4e2d\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e09\u7bc7\u300b\u660e\u786e\u6307\u51fa\uff0c\u4e24\u7528\u58c1\u6302\u7089\u7684<strong>\u6700\u5c0f\u8f93\u51fa\u529f\u7387\uff088-10kW\uff09\u8fdc\u8d85\u5c0f\u9762\u79ef\u91c7\u6696\u5b9e\u9645\u9700\u6c42\uff08\u7ea65kW\uff09<\/strong>\u3002\u6e7f\u6cd5\u56de\u586b\u7684<strong>\u539a\u6df7\u51dd\u571f\u5c42\uff08\u226550mm\uff09<\/strong> \u5177\u6709\u5de8\u5927\u70ed\u5bb9\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u70ed\u91cf\u201c\u84c4\u6c34\u6c60\u201d<\/strong>\uff1a\u9505\u7089\u5728\u4f4e\u8d1f\u8377\u8fd0\u884c\u65f6\uff0c\u591a\u4f59\u70ed\u91cf\u88ab\u6df7\u51dd\u571f\u5145\u5438\u6536\u50a8\u5b58\uff0c\u800c\u4e0d\u662f\u5bfc\u81f4\u673a\u8eab\u9891\u7e41\u542f\u505c\u3002<\/li>\n\n<li><strong>\u201c\u524a\u5cf0\u586b\u8c37\u201d<\/strong>\uff1a\u9505\u7089\u542f\u52a8\u65f6\uff0c\u84c4\u70ed\u5c42\u5148\u5438\u6536\u70ed\u91cf\u518d\u7f13\u6162\u91ca\u653e\uff1b\u9505\u7089\u505c\u673a\u65f6\uff0c\u84c4\u70ed\u5c42\u7ee7\u7eed\u6563\u70ed\uff0c\u7ef4\u6301\u5ba4\u6e29\u7a33\u5b9a\u3002\u8fd9\u76f4\u63a5\u6d88\u9664\u4e86\u201c\u9505\u7089\u9891\u7e41\u542f\u505c\u201d\u8fd9\u4e00\u6838\u5fc3\u75db\u70b9\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u5747\u70ed\u6027\u66f4\u4f73<\/strong>\uff1a\u84c4\u70ed\u5c42\u80fd\u5c06\u7ba1\u9053\u7684\u4e0d\u5747\u5300\u70ed\u91cf\u5145\u5206\u6df7\u5408\uff0c\u786e\u4fdd\u6574\u4e2a\u5730\u9762\u6e29\u5ea6<strong>\u5747\u5300\u4e00\u81f4<\/strong>\uff0c\u6e29\u5dee\u53ef\u63a7\u5236\u5728**\u00b11\u2103**\u4ee5\u5185\u3002<\/li>\n\n<li><strong>\u80fd\u8017\u5f71\u54cd<\/strong>\uff1a\u867d\u7136\u84c4\u70ed\u5c42\u672c\u8eab\u4f1a\u6709\u4e00\u70b9\u70ed\u635f\u5931\uff0c\u4f46\u5b83\u901a\u8fc7<strong>\u6291\u5236\u9505\u7089\u9891\u7e41\u542f\u505c\u3001\u51cf\u5c11\u65e0\u6548\u4ea7\u70ed<\/strong>\uff0c\u5b9e\u9645\u4e0a<strong>\u6574\u4f53\u80fd\u8017\u53ef\u80fd\u66f4\u4f4e<\/strong>\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>2. \u5e72\u6cd5\u94fa\u88c5\uff08\u9884\u5236\u6c9f\u69fd\u677f\uff09\uff1a\u5373\u70ed\u5f0f\u7cfb\u7edf\u7684\u4f18\u52bf\u4e0e\u4ee3\u4ef7<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4f18\u52bf\uff1a\u54cd\u5e94\u5feb\u3001\u5c42\u9ad8\u4f4e<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li>\u5347\u6e29\u901f\u5ea6\u5feb\uff0830\u5206\u949f-1\u5c0f\u65f6\uff09\uff0c\u9002\u5408<strong>\u95f4\u6b47\u6027\u4f9b\u6696<\/strong>\u573a\u666f\u3002<\/li>\n\n<li>\u5bf9\u5c42\u9ad8\u5f71\u54cd\u5c0f\uff08\u9884\u5236\u677f\u226435mm\uff09\uff0c\u9002\u5408\u5c42\u9ad8\u53d7\u9650\u7684\u4f4f\u5b85\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u52a3\u52bf\uff1a\u5bf9\u8f93\u914d\u4e0e\u63a7\u5236\u63d0\u51fa\u66f4\u9ad8\u8981\u6c42<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u52a0\u5267\u70ed\u6e90\u529f\u7387\u4e0d\u5339\u914d<\/strong>\uff1a\u7531\u4e8e\u6ca1\u6709\u84c4\u70ed\u7f13\u51b2\uff0c\u5e72\u6cd5\u7cfb\u7edf<strong>\u65e0\u6cd5\u7f13\u89e3\u9505\u7089\u529f\u7387\u8fc7\u5269\u95ee\u9898<\/strong>\u3002\u5982\u679c\u70ed\u6e90\u6700\u5c0f\u8f93\u51fa\u4f9d\u7136\u5927\u4e8e\u9700\u6c42\uff0c\u9505\u7089<strong>\u4ecd\u4f1a\u9891\u7e41\u542f\u505c<\/strong>\uff0c\u5bfc\u81f4\u7cfb\u7edf\u4e0d\u7a33\u5b9a\u548c\u80fd\u8017\u589e\u52a0\u3002<\/li>\n\n<li><strong>\u5747\u70ed\u6027\u6311\u6218<\/strong>\uff1a\u70ed\u91cf\u5b8c\u5168\u4f9d\u8d56\u9884\u5236\u6c9f\u69fd\u677f\u4e0a\u9644\u5e26\u7684<strong>\u91d1\u5c5e\u5747\u70ed\u5c42\uff08\u94dd\u7b94\uff09<\/strong> \u8fdb\u884c\u6a2a\u5411\u4f20\u5bfc\u3002\u5982\u679c\u5747\u70ed\u5c42\u94fa\u8bbe\u9762\u79ef\u4e0d\u591f\u3001\u5bfc\u70ed\u6027\u80fd\u4e0d\u4f73\u6216\u62fc\u63a5\u4e0d\u4e25\u5bc6\uff0c\u6781\u6613\u51fa\u73b0<strong>\u76d8\u7ba1\u5904\u5730\u9762\u8fc7\u70ed\u3001\u7ba1\u95f4\u533a\u57df\u504f\u51b7<\/strong>\u7684\u6e29\u5ea6\u4e0d\u5747\u95ee\u9898\u3002<\/li>\n\n<li><strong>\u80fd\u8017\u5f71\u54cd<\/strong>\uff1a<strong>\u5728\u8fde\u7eed\u4f9b\u6696\u6a21\u5f0f\u4e0b\uff0c\u5e72\u6cd5\u7cfb\u7edf\u80fd\u8017\u53ef\u80fd\u9ad8\u4e8e\u6e7f\u6cd5<\/strong>\u3002\u56e0\u4e3a\u5176\u84c4\u70ed\u80fd\u529b\u5f31\uff0c\u70ed\u6e90\u9700\u66f4\u9891\u7e41\u542f\u52a8\u624d\u80fd\u7ef4\u6301\u5ba4\u6e29\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>3. \u6838\u5fc3\u7ed3\u8bba\u4e0e\u5efa\u8bae<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5bf9\u65b0\u88c5\u4f4f\u5b85\uff08\u5927\u9762\u79ef\u4e3b\u529b\u91c7\u6696\u533a\uff09<\/strong>\uff1a<strong>\u4f18\u5148\u63a8\u8350\u6e7f\u6cd5\u56de\u586b<\/strong>\u3002\u5229\u7528\u5176\u84c4\u70ed\u7279\u6027\uff0c\u53ef\u6781\u5927\u7f13\u89e3\u4e24\u7528\u58c1\u6302\u7089\u7684\u529f\u7387\u5339\u914d\u95ee\u9898\uff0c\u5b9e\u73b0\u66f4\u7a33\u5b9a\u3001\u66f4\u5747\u5300\u7684\u91c7\u6696\u6548\u679c\u3002<\/li>\n\n<li><strong>\u5bf9\u8001\u623f\u6539\u9020\u3001\u5c42\u9ad8\u53d7\u9650\u7684\u5c40\u90e8\u7a7a\u95f4<\/strong>\uff1a<strong>\u8003\u8651\u5e72\u6cd5\u94fa\u88c5<\/strong>\uff0c\u9700\u6ce8\u610f<strong>\u5fc5\u987b\u786e\u4fdd\u70ed\u6e90\u80fd\u591f\u7cbe\u7ec6\u8c03\u8282\u3001\u7cfb\u7edf\u6c34\u529b\u5e73\u8861\u826f\u597d<\/strong>\u3002<\/li>\n\n<li><strong>\u7ec8\u6781\u65b9\u6848<\/strong>\uff1a<strong>\u201c\u6e7f\u6cd5\u94fa\u4e3b\u529b\u533a + \u5e72\u6cd5\u94fa\u5c40\u90e8\u533a\u201d<\/strong> \u7684\u590d\u5408\u65b9\u6848\uff0c\u5b9e\u73b0\u957f\u6548\u7a33\u5b9a\u4e0e\u7075\u6d3b\u54cd\u5e94\u517c\u987e\u3002<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">4.2.3 \u4e8c\u6b21\u7cfb\u7edf\u5224\u65ad\uff08\u58c1\u6302\u7089 vs \u7a7a\u6c14\u80fd\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u6c34\u6cf5\u9009\u578b\u2014\u2014\"\u5c0f\u6d41\u91cf\u5927\u6e29\u5dee\"\u662f\u80fd\u8017\u9ed1\u6d1e<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\">\u4f20\u7edf\"\u9009\u5927\u4e0d\u9009\u5c0f\"\u7684\u95ee\u9898\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u80fd\u8017\u9ed1\u6d1e<\/strong>\uff1a\u6c34\u6cf5\u957f\u671f\u9ad8\u529f\u7387\u8fd0\u884c\uff0c\u5927\u6d41\u91cf\u5bfc\u81f4\u4f9b\u56de\u6c34\u6e29\u5dee\u7f29\u5c0f\uff08\u0394T\u4ece10\u2103\u964d\u52303-5\u2103\uff09\uff0c\u9505\u7089\u88ab\u8feb\u63d0\u9ad8\u51fa\u6c34\u6e29\u5ea6\u8865\u507f<\/li>\n\n<li><strong>\u7cfb\u7edf\u566a\u97f3<\/strong>\uff1a\u6c34\u6d41\u901f\u5ea6\u8fc7\u5feb\uff0c\u7ba1\u9053\u5185\u4ea7\u751f\u6c34\u6d41\u566a\u58f0<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">\u6b63\u786e\u505a\u6cd5\uff1a\u6309\u8bbe\u8ba1\u70ed\u8d1f\u8377\u8ba1\u7b97\u5b9e\u9645\u9700\u6c42\u6d41\u91cf\uff0c\u9009\u578b\u6c34\u6cf5\u4f7f\u5176\u5de5\u4f5c\u5728\u9ad8\u6548\u533a\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u58c1\u6302\u7089\u5730\u6696\u6bd4\u7a7a\u6c14\u80fd\u5730\u6696\u66f4\u9700\u8981\u505a\u4e8c\u6b21\u7cfb\u7edf\u7684\u539f\u56e0\uff0c\u6838\u5fc3\u5728\u4e8e<strong>\u4e24\u8005\u7684\u4e3b\u673a\u7279\u6027\u3001\u5185\u7f6e\u6c34\u6cf5\u80fd\u529b\u548c\u7cfb\u7edf\u67b6\u6784\u8bbe\u8ba1\u5b58\u5728\u6839\u672c\u6027\u5dee\u5f02<\/strong>\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u58c1\u6302\u7089\uff08\u5e38\u89c4\/\u51b7\u51dd\uff09<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u6c14\u80fd\uff08\u5168\u53d8\u9891\u70ed\u6cf5\uff09<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u7ed3\u8bba<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u673a\u529f\u7387<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e25\u91cd\u8fc7\u5269<\/strong>\u300224kW\u662f\u5e38\u89c1\u8d77\u6b65\u578b\u53f7\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7cbe\u51c6\u5339\u914d<\/strong>\u300212.5kW\uff08\u5339\u914d100\u33a1\uff09\u662f\u5e38\u89c1\u914d\u7f6e\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u58c1\u6302\u7089\u7684\u201c\u5927\u9a6c\u62c9\u5c0f\u8f66\u201d\u95ee\u9898\u662f\u6839\u6e90\u3002<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5185\u7f6e\u6c34\u6cf5<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5c0f\u5b9a\u9891\u6cf5<\/strong>\u3002\u6807\u914d15-6\u6cf5\uff0c\u5b9e\u9645\u6d41\u91cf\u4ec5700-900L\/h\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53d8\u9891\u6cf5<\/strong>\u3002\u6c34\u6cf5\u4e0e\u4e3b\u673a\u5339\u914d\uff0c\u53ef\u81ea\u52a8\u8c03\u8282\u6d41\u91cf\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u58c1\u6302\u7089\u7684\u201c\u8fd0\u529b\u201d\u4e25\u91cd\u4e0d\u8db3\u3002<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6838\u5fc3\u77db\u76fe<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u529f\u7387\u5927 + \u6d41\u91cf\u5c0f<\/strong> \u2192 \u9891\u7e41\u542f\u505c\u3001\u65e0\u6548\u4ea7\u70ed\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u529f\u7387\u5339\u914d + \u6d41\u91cf\u81ea\u8c03<\/strong> \u2192 \u8fde\u7eed\u8fd0\u884c\u3001\u6548\u7387\u9ad8\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u58c1\u6302\u7089\u7684\u7269\u7406\u77db\u76fe\u9700\u8981\u4e8c\u6b21\u7cfb\u7edf\u6765\u201c\u89e3\u8026\u201d\u3002<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u4f55\u65f6\u9700\u8981\u505a\u4e8c\u6b21\u7cfb\u7edf\uff1f<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u662f\u5426\u9700\u8981\u4e8c\u6b21\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5224\u65ad\u4f9d\u636e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6696\u6c14\u7247\u7cfb\u7edf + \u58c1\u6302\u7089\u5185\u7f6e\u6cf5\u76f4\u63a5\u4f9b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u26a0\ufe0f <strong>100\u33a1\u4ee5\u4e0a\u5efa\u8bae\u505a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5185\u7f6e\u6cf5\u6d41\u91cf\u4e25\u91cd\u4e0d\u8db3\uff0c\u9700\u5916\u7f6e\u5927\u6d41\u91cf\u6cf5\u89e3\u8026<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5730\u6696\u7cfb\u7edf + \u58c1\u6302\u7089<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c <strong>\u4e00\u822c\u4e0d\u9700\u8981<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u6e29\u5dee\u5c0f\uff0c\u6d41\u91cf\u9700\u6c42\u76f8\u5bf9\u4f4e\uff0c\u53ef\u5229\u7528\u56de\u586b\u5c42\u84c4\u70ed<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u522b\u5885\/\u5927\u5e73\u5c42\u6696\u6c14\u7247\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 <strong>\u5fc5\u987b\u505a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7ba1\u8def\u957f\u3001\u672b\u7aef\u591a\uff0c\u5355\u9760\u5185\u7f6e\u6cf5\u65e0\u6cd5\u6ee1\u8db3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u7ed3\u8bba<\/strong>\uff1a<strong>\u6696\u6c14\u7247\u7cfb\u7edf\u6bd4\u5730\u6696\u7cfb\u7edf\u66f4\u9700\u8981\u4e8c\u6b21\u7cfb\u7edf<\/strong>\u3002\u4e0d\u505a\u4e8c\u6b21\u7cfb\u7edf\uff0c\u6d41\u91cf\u7f3a\u53e3\u8d85\u8fc750%\uff0c\u70ed\u91cf\u65e0\u6cd5\u53ca\u65f6\u8f93\u9001\uff0c\u8fd9\u662f\u201c\u9891\u7e41\u542f\u505c\u3001\u80fd\u8017\u9ad8\u201d\u7684\u7269\u7406\u6839\u6e90\u3002<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">4.3 \u63a7\u5236\u7cfb\u7edf\uff08\u201c\u5927\u8111\u4e0e\u795e\u7ecf\u201d\uff09<\/h3>\n\n<p class=\"wp-block-paragraph\">\u63a7\u5236\u7cfb\u7edf\u662f\u5730\u6696\u7cfb\u7edf\u7684\u201c\u603b\u6307\u6325\u201d\uff0c\u8d1f\u8d23\u8c03\u8282\u201c\u4ec0\u4e48\u65f6\u5019\u4ea7\u70ed\u3001\u4ec0\u4e48\u65f6\u5019\u505c\u3001\u4ea7\u591a\u5c11\u70ed\u201d\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">4.3.1 \u6838\u5fc3\u77db\u76fe\uff1a\u6c34\u6e29\u63a7\u5236 vs \u5ba4\u6e29\u63a7\u5236<\/h4>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u7406\u89e3\u63a7\u5236\u7cfb\u7edf\u6700\u57fa\u7840\u7684\u903b\u8f91\uff1a<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u65b9\u5f0f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u5bf9\u8c61<\/th><th class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/longmai-nt.com\/?page_id=3872\">\u4e24\u7528\u58c1\u6302\u7089\u5de5\u4f5c\u539f\u7406<\/a><\/th><th class=\"has-text-align-left\" data-align=\"left\">\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5178\u578b\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6c34\u6e29\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\/\u70ed\u6e90<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u68c0\u6d4b\u51fa\u6c34\u6216\u56de\u6c34\u6e29\u5ea6\uff0c\u6e29\u5ea6\u4f4e\u4e8e\u8bbe\u5b9a\u503c\u5219\u70b9\u706b\u52a0\u70ed\uff0c\u8fbe\u5230\u8bbe\u5b9a\u503c\u5219\u505c\u673a\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e0\u6548\u4ea7\u70ed<\/strong>\uff1a\u5ba4\u6e29\u5df2\u8fbe\u6807\uff0c\u4f46\u9505\u7089\u4ecd\u5728\u70e7\u6c34\uff0c\u9020\u6210\u80fd\u6e90\u6d6a\u8d39\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672a\u505a\u8054\u52a8\u63a7\u5236\u7684\u4f20\u7edf\u58c1\u6302\u7089\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5ba4\u6e29\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u623f\u95f4\/\u533a\u57df<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e29\u63a7\u5668\u68c0\u6d4b\u5ba4\u5185\u7a7a\u6c14\u6e29\u5ea6\uff0c\u6e29\u5ea6\u4f4e\u4e8e\u8bbe\u5b9a\u503c\u5219\u5f00\u542f\u9600\u95e8\/\u542f\u52a8\u9505\u7089\uff0c\u8fbe\u6807\u540e\u5173\u95ed\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u54cd\u5e94\u6ede\u540e<\/strong>\uff1a\u6e29\u63a7\u5668\u52a8\u4f5c\u540e\uff0c\u9505\u7089\u9700\u8981\u65f6\u95f4\u53cd\u5e94\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u914d\u7f6e\u4e86\u8054\u52a8\u7cfb\u7edf\u7684\u73b0\u4ee3\u5730\u6696\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">4.3.2 \u63a7\u5236\u7c7b\u578b\u6f14\u8fdb\u4e0e\u5bf9\u6bd4<\/h4>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u7528\u573a\u666f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8282\u80fd\u6548\u679c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u4ef7\u503c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u624b\u52a8\u9600\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u624b\u52a8\u5f00\u5173\u3001\u8c03\u8282\u9600\u95e8\uff0c\u65e0\u4efb\u4f55\u81ea\u52a8\u8054\u52a8\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9884\u7b97\u6781\u4f4e\uff0c\u77ed\u671f\u8fc7\u6e21\u4f7f\u7528\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e0\u8282\u80fd\u6548\u679c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ec5\u6ee1\u8db3\u57fa\u7840\u5f00\u5173\uff0c\u65e0\u6cd5\u7cbe\u7ec6\u5316\u63a7\u6e29\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6e29\u63a7\u9600\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ea\u52a8\u8c03\u8282\u5ba4\u6e29\uff08\u5f00\u5173\u672b\u7aef\u9600\u95e8\uff09\uff0c\u4f46\u4e0e\u9505\u7089\u65e0\u8054\u52a8\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u57fa\u7840\u5206\u5ba4\u63a7\u6e29\uff0c\u4e0d\u8ffd\u6c42\u6781\u81f4\u8282\u80fd\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8282\u80fd 5%-10%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5404\u623f\u95f4\u72ec\u7acb\u63a7\u6e29\uff0c\u4f46\u9505\u7089\u4ecd\u5728\u201c\u65e0\u8111\u70e7\u201d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u63a7\u5236\u5668\u52a8\u6001\u8c03\u8282\u9505\u7089\u8f93\u51fa\uff0c\u7cbe\u51c6\u5339\u914d\u5ba4\u6e29\u9700\u6c42\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8ffd\u6c42\u8282\u80fd\u6548\u679c\uff0c\u56de\u672c\u5468\u671f\u77ed\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8282\u80fd 10%-25%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u63a8\u8350\u65b9\u6848<\/strong>\uff0c\u907f\u514d\u65e0\u6548\u4ea7\u70ed\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u667a\u80fd\u8054\u52a8\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">APP\u8fdc\u7a0b\u63a7\u5236\uff0c\u573a\u666f\u8054\u52a8\uff08\u56de\u5bb6\/\u79bb\u5bb6\/\u7761\u7720\uff09\uff0cAI\u5b66\u4e60\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8ffd\u6c42\u4fbf\u6377\u4e0e\u6781\u81f4\u8282\u80fd\uff0c\u5927\u6237\u578b\/\u522b\u5885\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8282\u80fd 15%-30%<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u952e\u573a\u666f\uff0c\u5206\u57df\u5206\u65f6\uff0c\u81ea\u52a8\u5316\u8fd0\u884c\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">4.3.3 \u6838\u5fc3\u90e8\u4ef6\u4e0e\u6b63\u786e\u8054\u52a8\u903b\u8f91<\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u90e8\u4ef6<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u90e8\u4ef6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u529f\u80fd<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5173\u952e\u53c2\u6570\/\u914d\u7f6e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ee3\u8868\u54c1\u724c<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9505\u7089\u63a7\u5236\u5668<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63a5\u6536\u8054\u52a8\u4fe1\u53f7\uff0c\u63a7\u5236\u9505\u7089\u542f\u505c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u4e0e\u9505\u7089\u534f\u8bae\u5339\u914d\uff08\u5982OT\u3001eBus\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7\uff08\u77e5\u8bc6\u5e93\u9ed8\u8ba4\u914d\u7f6e\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5ba4\u6e29\u63a7\u5236\u5668<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u611f\u77e5\u5ba4\u5185\u6e29\u5ea6\uff0c\u8f93\u51fa\u5f00\u5173\u4fe1\u53f7\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5e26WiFi<\/strong>\uff1a\u652f\u6301\u8fdc\u7a0b\u63a7\u5236\u3002<strong>\u63a7\u5236\u7cbe\u5ea6<\/strong>\uff1a\u00b10.5\u2103\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7 RT1.23i\u3001\u65e5\u7acb SXC-TD01<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7535\u70ed\u6267\u884c\u5668<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63a5\u6536\u6e29\u63a7\u5668\u4fe1\u53f7\uff0c\u5f00\u5173\u5730\u6696\u56de\u8def\u9600\u95e8\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">AC220V\uff0c\u5e38\u95ed\u578b\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7 SEH35.23<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8054\u52a8\u63a7\u5236\u6a21\u5757<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b9e\u73b0\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u7684\u6709\u6548\u901a\u8baf\u8054\u52a8\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u6839\u636e\u5177\u4f53\u9505\u7089\u548c\u6e29\u63a7\u5668\u54c1\u724c\u9009\u914d\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66fc\u745e\u5fb7 H-BOX<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6b63\u786e\u8054\u52a8\u903b\u8f91<\/strong><\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u5ba4\u6e29\u4f20\u611f\u5668\u68c0\u6d4b \u2192 \u5ba4\u6e29\u4f4e\u4e8e\u8bbe\u5b9a \u2192 \u8054\u52a8\u542f\u52a8\u6c34\u6cf5 \u2192 \u8054\u52a8\u542f\u52a8\u9505\u7089 \u2192 \u70ed\u6c34\u5faa\u73af \u2192 \u5ba4\u6e29\u8fbe\u6807 \u2192 \u8054\u52a8\u505c\u673a<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u96be\u70b9<\/strong>\uff1a\u6c34\u7cfb\u7edf\u3001\u5730\u6696\u548c\u6696\u6c14\u7247\u7cfb\u7edf\u90fd\u662f\u5404\u79cd\u54c1\u724c\u96c6\u6210\u5316\u7684\u7cfb\u7edf\u3002<strong>\u975e\u4e13\u4e1a\u6027\u7684\u670d\u52a1<\/strong>\u4f1a\u5bfc\u81f4\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u274c \u6c34\u6cf5\u4e0d\u8054\u52a8\uff0824\u5c0f\u65f6\u8f6c\uff0c\u7535\u8d39\u98d9\u5347\uff09\u3002<\/li>\n\n<li>\u274c \u9505\u7089\u6309\u6c34\u6e29\u542f\u505c\uff08\u5ba4\u6e29\u8fbe\u6807\u4e86\u8fd8\u5728\u70e7\uff0c\u65e0\u6548\u4ea7\u70ed\uff09\u3002<\/li>\n\n<li>\u274c \u6e29\u63a7\u4e0e\u9505\u7089\u5404\u81ea\u4e3a\u653f\uff08\u80fd\u8017\u9ad8\u3001\u6548\u679c\u5dee\uff09\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u7ed3\u8bba<\/strong>\uff1a\u8054\u52a8\u63a7\u5236\u662f\u6d89\u6c34\u7cfb\u7edf\u6700\u96be\u3001\u4e5f\u6700\u9700\u8981\u4e13\u4e1a\u5316\u8bbe\u8ba1\u7684\u73af\u8282\u3002<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h3 class=\"wp-block-heading\">4.4 \u201c\u56db\u8981\u7d20\u201d\u5339\u914d\u7684\u9ec4\u91d1\u6cd5\u5219<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5728\u4efb\u4f55\u6696\u901a\u7cfb\u7edf\u4e2d\uff0c\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u56db\u8005\u5fc5\u987b\u7cbe\u786e\u5339\u914d\uff0c\u7f3a\u4e00\u4e0d\u53ef\u3002<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u53e5\u8bdd\u603b\u7ed3<\/strong>\uff1a<strong>\u4ea7\u7684\u70ed\u62c9\u4e0d\u8d70\uff0c\u70ed\u6e90\u81ea\u635f\uff1b\u62c9\u6765\u7684\u70ed\u6563\u4e0d\u6389\uff0c\u5bb6\u91cc\u4e0d\u70ed\u3002\u529f\u7387\u5339\u914d\u6bd4\u529f\u7387\u5927\u66f4\u91cd\u8981\u3002<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\"><strong>\u5185\u94fe\uff1a\u56db\u8981\u7d20\u5339\u914d\u5931\u8d25\u6848\u4f8b \u2194 \u5404\u75db\u70b9\u7ae0\u8282<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5339\u914d\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6848\u4f8b\u8bf4\u660e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u75db\u70b9\u6620\u5c04\uff08\u5feb\u901f\u5b9a\u4f4d\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u6e90\u4e0d\u5339\u914d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8a89\u5cf0\u6848\u4f8b\uff0c35kW\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u8fdc\u5927\u4e8e\u5b9e\u9645\u9700\u6c42\uff0c\u5bfc\u81f4\u9891\u7e41\u542f\u505c\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[2.2\u8282 - \u8bef\u533a\u4e00]<\/strong> \u201c\u9505\u7089\u529f\u7387\u8d8a\u5927\u8d8a\u597d\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8f93\u914d\u4e0d\u5339\u914d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u67d0\u623f\u95f4\u4e0d\u70ed\uff0c\u56e0\u91c7\u7528\u5f02\u7a0b\u5e76\u8054\u4e14\u672a\u505a\u6c34\u529b\u5e73\u8861\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[4.1.3\u8282]<\/strong> \u201c\u6c34\u529b\u5e73\u8861\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u63a7\u5236\u4e0d\u5339\u914d<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9505\u7089\u4ec5\u51ed\u6c34\u6e29\u63a7\u5236\uff0c\u65e0\u5ba4\u6e29\u8054\u52a8\uff0c\u5bfc\u81f4\u65e0\u6548\u52a0\u70ed\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>[4.3.1\u8282]<\/strong> \u201c\u6c34\u6e29\u63a7\u5236 vs \u5ba4\u6e29\u63a7\u5236\u201d<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u6700\u7ec8\u7ed3\u8bba<\/strong>\uff1a\u4e00\u4e2a\u5b8c\u7f8e\u7684\u5730\u6696\u7cfb\u7edf\uff0c\u4e0d\u662f\u9760\u5806\u780c\u6700\u597d\u7684\u8bbe\u5907\uff0c\u800c\u662f\u9760\u8ba9\u201c\u4ea7\u3001\u8fd0\u3001\u7528\u3001\u63a7\u201d\u8fd9\u56db\u4e2a\u73af\u8282\u534f\u540c\u5de5\u4f5c\u3001\u7cbe\u786e\u5339\u914d\u3002\u8fd9\u9700\u8981\u4e13\u4e1a\u7684\u8bbe\u8ba1\u3001\u7cbe\u5de5\u7684\u5b89\u88c5\u548c\u667a\u80fd\u7684\u63a7\u5236\u3002<\/p>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u4e94\u7ae0\uff1a\u54c1\u724c\u9635\u8425\u4e0e\u9009\u578b\u51b3\u7b56<\/h2>\n\n<p class=\"wp-block-paragraph\">\u5728\u4e86\u89e3\u4e86\u5730\u6696\u7cfb\u7edf\u7684\u5de5\u4f5c\u539f\u7406\u548c\u6838\u5fc3\u90e8\u4ef6\u540e\uff0c\u60a8\u53ef\u80fd\u4f1a\u95ee\uff1a\u201c\u90a3\u5e02\u9762\u4e0a\u8fd9\u4e48\u591a\u54c1\u724c\uff0c\u6211\u5230\u5e95\u8be5\u600e\u4e48\u9009\uff1f\u201d<\/p>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u4e00\u7ae0\uff0c\u6211\u4eec\u5c06\u4e3a\u60a8\u68b3\u7406\u77e5\u8bc6\u5e93\u4e2d\u6536\u5f55\u7684\u4e3b\u6d41\u5730\u6696\u54c1\u724c\uff0c\u5e76\u63d0\u4f9b\u4e00\u4e2a\u6e05\u6670\u7684<strong>\u9009\u578b\u51b3\u7b56\u6811<\/strong>\uff0c\u5e2e\u52a9\u60a8\u57fa\u4e8e\u81ea\u8eab\u9700\u6c42\u505a\u51fa\u6700\u7406\u6027\u7684\u9009\u62e9\uff0c\u800c\u975e\u76f2\u76ee\u8ffd\u6c42\u54c1\u724c\u540d\u6c14\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u672c\u7ae0\u5185\u5bb9\u4e25\u683c\u9075\u5faa\u77e5\u8bc6\u5e93\u539f\u5219\uff1a<strong>\u53ea\u5217\u54c1\u724c\u540d\u79f0\u3001\u5b9a\u4f4d\u4e0e\u5ba2\u89c2\u9648\u8ff0\uff0c\u4e0d\u5c55\u5f00\u5177\u4f53\u4ea7\u54c1\u53c2\u6570\uff0c\u4e0d\u8fdb\u884c\u4e3b\u89c2\u4f18\u52a3\u6392\u540d<\/strong>\u3002\u5b8c\u6574\u53c2\u6570\u4e0e\u5b89\u88c5\u6848\u4f8b\uff0c\u8bf7\u53c2\u8003\u540e\u7eed\u72ec\u7acb\u7684\u54c1\u724c\u4e13\u9898\u8be6\u60c5\u9875\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">5.1 \u6838\u5fc3\u54c1\u724c\u4ecb\u7ecd\uff08\u5ba2\u89c2\u9648\u8ff0\uff09<\/h3>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u77e5\u8bc6\u5e93\u300a\u54c1\u724c\u9635\u8425\u300b\u7ae0\u8282\u5185\u5bb9\uff0c\u9f99\u8109\u5730\u6696\u4f18\u9009\u54c1\u724c\u6309\u70ed\u6e90\u7c7b\u578b\u5206\u4e3a\u4e09\u5927\u9635\u8425\uff1a<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9a71\u52a8\u65b9\u5f0f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u54c1\u724c\u9635\u8425<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b9a\u4f4d\u4e0e\u7279\u70b9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9505\u7089\u70ed\u6e90<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u71c3\u6c14\u58c1\u6302\u7089\u9a71\u52a8\u6c34\u5730\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u83f2\u65af\u66fc\u3001\u535a\u4e16\u3001\u66fc\u745e\u5fb7\u3001\u6797\u5185<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\u6210\u719f\u3001\u91c7\u6696+\u70ed\u6c34\u4e00\u4f53\u3001\u5927\u9762\u79ef\u7ecf\u6d4e\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u6c14\u80fd\u70ed\u6e90<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u6c14\u80fd\u70ed\u6cf5\u9a71\u52a8\u6c34\u5730\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e5\u7acb\u3001\u6d77\u4fe1\u3001\u7ebd\u6069\u6cf0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">1\u5ea6\u7535\u642c3\u5ea6\u70ed\u3001\u8fd0\u884c\u8d39\u6700\u4f4e\u3001\u96f6\u78b3\u65b9\u5411\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53d1\u70ed\u7535\u7f06<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7535\u80fd\u76f4\u70ed\u5f0f\u5730\u6696<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u827e\u9ed8\u751f\u3001\u6c49\u5821\u9601<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u9762\u79ef\u7075\u6d3b\u3001\u514d\u7ef4\u62a4\u300130-50\u5e74\u5bff\u547d\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u91cd\u8981\u8bf4\u660e<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u4ee5\u4e0a\u54c1\u724c\u4e3a\u9f99\u8109\u6696\u901a\u6839\u636e\u5e02\u573a\u8c03\u7814\u4e0e\u957f\u671f\u670d\u52a1\u7ecf\u9a8c\u7b5b\u9009\u51fa\u7684\u4f18\u9009\u5408\u4f5c\u4f19\u4f34\u3002<\/li>\n\n<li>\u5404\u54c1\u724c\u5185\u90e8\u6709\u4e0d\u540c\u7cfb\u5217\u548c\u578b\u53f7\uff0c\u5206\u522b\u5bf9\u5e94\u4e0d\u540c\u9884\u7b97\u548c\u573a\u666f\uff08\u5982\u65e5\u7acb\u6709<strong>\u6c34\u5885\u9002VF\u7cfb\u5217<\/strong>\uff08\u5929\u6c34\u5730\u6c34\uff09\u548c<strong>\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757<\/strong>\uff08\u5929\u6c1f\u5730\u6c34\uff09\uff09\u3002<\/li>\n\n<li>\u672c\u7ae0\u8282\u4ec5\u505a\u54c1\u724c\u63a8\u8350\u7d22\u5f15\u3002\u5173\u4e8e\u5404\u54c1\u724c\u7684\u5177\u4f53\u4ea7\u54c1\u53c2\u6570\u3001\u6280\u672f\u89e3\u6790\u3001\u5b89\u88c5\u89c4\u8303\u4e0e\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\uff0c\u8bf7\u53c2\u8003\u6211\u4eec\u5df2\u4e0a\u7ebf\u6216\u6b63\u5728\u5efa\u8bbe\u4e2d\u7684<strong>\u54c1\u724c\u4e13\u9898\u8be6\u60c5\u9875<\/strong>\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u9f99\u8109\u9996\u63a8\u65b9\u6848\uff08\u6309\u6237\u578b\u5206\u7c7b\uff09<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6237\u578b\u573a\u666f<\/th><th>\u63a8\u8350\u65b9\u6848<\/th><th>\u65b9\u6848\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u6210\u90fd\u5e73\u5c42\uff0880-140\u33a1\uff09<\/td><td>\u65e5\u7acb\u667a\u4eab\u5929\u6c1f\u5730\u6c34 \u6216 \u66fc\u745e\u5fb7\u51b7\u51dd\u7089<\/td><td>\u65e5\u7acb\uff1a\u5236\u51b7+\u5730\u6696\u4e00\u4f53\uff0c\u8fd0\u884c\u8d39\u6700\u4f4e\uff1b\u66fc\u745e\u5fb7\uff1a\u5df2\u6709\u6210\u719f\u670d\u52a1\u4f53\u7cfb\u548c\u4e13\u9898\u9875<\/td><\/tr><tr><td>\u6210\u90fd\u5927\u5e73\u5c42\/\u522b\u5885\uff08150-300\u33a1\uff09<\/td><td>\u65e5\u7acb\u6c34\u5885\u9002\/\u667a\u4eab + \u83f2\u65af\u66fc\u58c1\u6302\u7089\uff08\u5907\u7528\uff09<\/td><td>\u7a7a\u6c14\u80fd\u4e3b\u529b\u91c7\u6696\uff0c\u83f2\u65af\u66fc\u58c1\u6302\u7089\u51ac\u5b63\u6781\u5bd2\u8865\u70ed+\u751f\u6d3b\u70ed\u6c34<\/td><\/tr><tr><td>\u5c0f\u6237\u578b\/\u5c40\u90e8\u91c7\u6696\uff085-30\u33a1\uff09<\/td><td>\u827e\u9ed8\u751f\/\u6c49\u5821\u9601\u53d1\u70ed\u7535\u7f06<\/td><td>\u7075\u6d3b\u94fa\u8bbe\uff0c\u521d\u88c5\u4f4e\uff0c\u514d\u7ef4\u62a4\uff0c30-50\u5e74\u5bff\u547d<\/td><\/tr><tr><td>\u5317\u65b9\u4e25\u5bd2\u5730\u533a<\/td><td>\u7ebd\u6069\u6cf0\/\u6d77\u4fe1\u8d85\u4f4e\u6e29\u7a7a\u6c14\u80fd + \u7535\u8f85\u70ed<\/td><td>\u8865\u6c14\u589e\u7113\u6280\u672f\uff0c-25\u2103\u7a33\u5b9a\u8fd0\u884c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">5.2 \u6838\u5fc3\u9009\u578b\u51b3\u7b56\u6811<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5f53\u5ba2\u6237\u95ee\u201c\u6211\u8be5\u9009\u54ea\u4e2a\u54c1\u724c\uff1f\u201d\u65f6\uff0c\u6b63\u786e\u7684\u56de\u7b54\u4e0d\u662f\u62a5\u4e00\u4e2a\u54c1\u724c\u540d\uff0c\u800c\u662f\u5148\u95ee\u6e05\u695a\u5ba2\u6237\u7684<strong>\u6838\u5fc3\u9700\u6c42\u548c\u5ba2\u89c2\u6761\u4ef6<\/strong>\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u9009\u578b\u51b3\u7b56\u6811\uff0c\u5c06\u5e2e\u52a9\u60a8\u5c06\u5ba2\u6237\u7684\u6a21\u7cca\u9700\u6c42\u8f6c\u5316\u4e3a\u6e05\u6670\u7684\u6280\u672f\u65b9\u6848\u65b9\u5411\u3002<\/p>\n\n<h4 class=\"wp-block-heading\"><strong>\u7b2c\u4e00\u6b65\uff1a\u5224\u65ad\u91c7\u6696\u9762\u79ef\u4e0e\u6c14\u6e90\u6761\u4ef6<\/strong><\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u9009\u578b\u51b3\u7b56\u6811<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<pre class=\"wp-block-code\"><code>\u4f60\u5bb6\u91c7\u6696\u9762\u79ef\u591a\u5927\uff1f\n\u2502\n\u251c\u2500 \u226580\u33a1\uff08\u5168\u5c4b\u91c7\u6696\uff09\n\u2502   \u251c\u2500 \u6709\u5929\u7136\u6c14 \u2192 \u71c3\u6c14\u58c1\u6302\u7089\u6c34\u5730\u6696\n\u2502   \u2502   \u251c\u2500 \u9884\u7b97\u5145\u8db3 + \u8ffd\u6c42\u8282\u80fd \u2192 \u51b7\u51dd\u7089 + \u7cfb\u7edf\u4f18\u5316\uff08\u6c34\u529b\u5e73\u8861+\u8054\u52a8\u63a7\u5236\uff09\n\u2502   \u2502   \u2514\u2500 \u9884\u7b97\u6709\u9650 \u2192 \u5e38\u89c4\u7089 + \u7cfb\u7edf\u4f18\u5316\n\u2502   \u2502\n\u2502   \u2514\u2500 \u65e0\u5929\u7136\u6c14 \/ \u8ffd\u6c42\u6700\u4f4e\u8fd0\u884c\u8d39 \u2192 \u7a7a\u6c14\u80fd\u6c34\u5730\u6696\n\u2502       \u251c\u2500 \u5357\u65b9\uff08\u51ac\u5b63\u2265-5\u2103\uff09\u2192 \u5e38\u89c4\u7a7a\u6c14\u80fd\u70ed\u6cf5\n\u2502       \u2514\u2500 \u5317\u65b9\uff08\u51ac\u5b63\u2264-15\u2103\uff09\u2192 \u8d85\u4f4e\u6e29\u7a7a\u6c14\u80fd\u70ed\u6cf5\n\u2502\n\u251c\u2500 30-80\u33a1\uff08\u4e2d\u7b49\u9762\u79ef\uff09\n\u2502   \u251c\u2500 \u6709\u5929\u7136\u6c14 \u2192 \u5c0f\u529f\u7387\u58c1\u6302\u7089\n\u2502   \u2514\u2500 \u65e0\u5929\u7136\u6c14 \u2192 \u7a7a\u6c14\u80fd\u5c0f\u578b\u53f7 \u6216 \u53d1\u70ed\u7535\u7f06\uff08\u89c6\u9884\u7b97\uff09\n\u2502\n\u2514\u2500 5-30\u33a1\uff08\u5c40\u90e8\u91c7\u6696\uff1a\u536b\u751f\u95f4\/\u4e66\u623f\/\u9633\u53f0\uff09\n    \u2514\u2500 \u53d1\u70ed\u7535\u7f06 \u2014\u2014 \u7075\u6d3b\u3001\u4f4e\u521d\u88c5\u3001\u514d\u7ef4\u62a4<\/code><\/pre>\n\n<h4 class=\"wp-block-heading\"><strong>\u7b2c\u4e8c\u6b65\uff1a\u6839\u636e\u6838\u5fc3\u9700\u6c42\u9501\u5b9a\u7cfb\u7edf\u7c7b\u578b<\/strong><\/h4>\n\n<p class=\"wp-block-paragraph\">\u5728\u786e\u5b9a\u4e86\u70ed\u6e90\u5927\u65b9\u5411\u540e\uff0c\u8fd8\u9700\u8981\u6839\u636e\u5ba2\u6237\u5bf9<strong>\u8212\u9002\u5ea6\u3001\u8282\u80fd\u6027\u548c\u529f\u80fd\u5b8c\u6574\u6027<\/strong>\u7684\u504f\u597d\uff0c\u8fdb\u4e00\u6b65\u9501\u5b9a\u5177\u4f53\u7684\u7cfb\u7edf\u5f62\u6001\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u9700\u6c42<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u7cfb\u7edf\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u4f18\u52bf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5178\u578b\u54c1\u724c\/\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9002\u5408\u8c01\uff08\u77e5\u8bc6\u5e93\u4f9d\u636e\uff09<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9ad8\u6027\u4ef7\u6bd4\u3001\u5236\u51b7\u5feb\u901f\u3001\u6280\u672f\u6210\u719f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6c1f\u7cfb\u7edf\u591a\u8054\u673a + \u71c3\u6c14\u9505\u7089\u5730\u6696\uff08\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u5236\u51b7\u5236\u70ed\u54cd\u5e94\u901f\u5ea6\u5feb<br>2. \u9664\u6e7f\u80fd\u529b\u5f3a<br>3. \u51b7\u51dd\u7089\u5730\u6696\u6280\u672f\u6210\u719f\u7a33\u5b9a<br>4. \u521d\u6295\u8d44\u76f8\u5bf9\u8f83\u4f4e<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u8c03<\/strong>: \u65e5\u7acb\u8212\u4eab\/VAM mini<br><strong>\u5730\u6696<\/strong>: \u83f2\u65af\u66fc\/\u535a\u4e16\u51b7\u51dd\u7089<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8ffd\u6c42\u9ad8\u6027\u4ef7\u6bd4\u3001\u4e60\u60ef\u6c1f\u7a7a\u8c03\u5feb\u901f\u5236\u51b7\u3001\u5bf9\u71c3\u6c14\u8d39\u7528\u4e0d\u654f\u611f\u7684\u5bb6\u5ead\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6700\u9ad8\u8212\u9002\u5ea6\u3001\u957f\u671f\u8282\u80fd\u3001\u51fa\u98ce\u67d4\u548c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5929\u6c34\u5730\u6c34<\/strong>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\uff08\u6c34\u7cfb\u7edf\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u6c34\u7cfb\u7edf\u7a7a\u8c03\uff0c\u51fa\u98ce\u67d4\u548c\uff0c\u4e0d\u5e72\u71e5<br>2. \u5730\u6696\u8fd0\u884c\u8d39\u7528\u4f4e\uff08\u6bd4\u71c3\u6c14\u770140%-60%\uff09<br>3. \u7cfb\u7edf\u96c6\u6210\u5ea6\u9ad8\uff0c\u7ef4\u62a4\u754c\u9762\u5355\u4e00<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u673a<\/strong>: \u65e5\u7acb\u6c34\u5885\u9002VF\u7cfb\u5217<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5c24\u5176\u9002\u5408\u5bb6\u6709\u8001\u4eba\/\u5c0f\u5b69\u3001\u6ce8\u91cd\u957f\u671f\u8282\u80fd\u3001\u8ffd\u6c42\u6700\u9ad8\u8212\u9002\u5ea6\u7684\u5bb6\u5ead\u3002<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u517c\u987e\u8282\u80fd\u4e0e\u5feb\u901f\u5236\u51b7\u3001\u6280\u672f\u6210\u719f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5929\u6c1f\u5730\u6c34<\/strong>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\uff08\u6c1f\u7cfb\u7edf+\u6c34\u6a21\u5757\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. \u7a7a\u8c03\u5236\u51b7\u4f7f\u7528\u6c1f\u7cfb\u7edf\uff0c\u5236\u51b7\u5f3a\u52b2\u5feb\u901f<br>2. \u5730\u6696\u4f7f\u7528\u6c34\u6a21\u5757\u9a71\u52a8\uff0c\u9ad8\u6548\u8282\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u673a<\/strong>: \u65e5\u7acb\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e2\u60f3\u8981\u5feb\u901f\u5236\u51b7\uff0c\u53c8\u60f3\u4eab\u53d7\u5730\u6696\u8282\u80fd\u8212\u9002\u7684\u7528\u6237\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\"><strong>\u54c1\u724c\u4e13\u9898\u9875\u5f15\u5bfc<\/strong><\/h4>\n\n<p class=\"wp-block-paragraph\">\u6bcf\u4e2a\u54c1\u724c\u4e13\u9898\u9875\u5305\u542b\uff1a\u54c1\u724c\u6545\u4e8b\u4e0e\u5386\u53f2\u3001\u6838\u5fc3\u6280\u672f\u89e3\u6790\u3001\u5168\u4ea7\u54c1\u7ebf\u53c2\u6570\u8868\u3001\u5b89\u88c5\u89c4\u8303\u4e0e\u914d\u7f6e\u6e05\u5355\u3001\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u3001\u4f7f\u7528\u4e0e\u7ef4\u62a4\u624b\u518c\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u5f53\u524d\u8fdb\u5ea6\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u2705 \u5df2\u4e0a\u7ebf\uff1a\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u4e13\u9898\u9875\uff08\u667a\u4eab\/\u6c34\u5885\u9002\/\u7ea2\u7130\u7cfb\u5217\u5168\u89e3\u6790\uff09\u3001\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u5730\u6696\u4e13\u9898\u9875<\/li>\n\n<li>\ud83d\udd27 \u5efa\u8bbe\u4e2d\uff1a\u83f2\u65af\u66fc\u58c1\u6302\u7089+\u70ed\u6c34\u7bb1\u4e13\u9898\u9875\u3001\u6d77\u4fe1\u7a7a\u6c14\u80fd\u5730\u6696\u4e13\u9898\u9875\u3001\u7ebd\u6069\u6cf0\u8d85\u4f4e\u6e29\u7a7a\u6c14\u80fd\u4e13\u9898\u9875\u3001\u827e\u9ed8\u751f\u53d1\u70ed\u7535\u7f06\u4e13\u9898\u9875<\/li>\n\n<li>\u66f4\u591a\u54c1\u724c\u4e13\u9898\u9875\u6301\u7eed\u5efa\u8bbe\u4e2d<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\"><strong>\u7b2c\u4e09\u6b65\uff1a\u4f7f\u7528\u201c\u4e09\u539f\u5219\u201d\u9501\u5b9a\u5177\u4f53\u578b\u53f7\uff08\u89c13.6\u8282\uff09<\/strong><\/h4>\n\n<p class=\"wp-block-paragraph\">\u5728\u786e\u5b9a\u4e86\u7cfb\u7edf\u7c7b\u578b\u540e\uff0c\u5c31\u9700\u8981\u6839\u636e\u623f\u5c4b\u9762\u79ef\u3001\u4fdd\u6e29\u60c5\u51b5\u548c\u4f7f\u7528\u4e60\u60ef\uff0c\u8fdb\u884c\u7cbe\u786e\u7684\u8d1f\u8377\u8ba1\u7b97\u548c\u4ea7\u54c1\u9009\u578b\uff0c\u5177\u4f53\u9075\u5faa\u7b2c\u4e09\u7ae0\u7684<strong>\u70ed\u6e90\u9009\u578b\u4e09\u539f\u5219<\/strong>\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">5.3 \u5e38\u89c1\u9009\u578b\u95ee\u9898\u901f\u67e5<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u63d0\u95ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u77e5\u8bc6\u5e93\u6807\u51c6\u5e94\u5bf9\u7b56\u7565<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5173\u8054\u7ae0\u8282<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c<strong>\u9505\u7089\u54ea\u4e2a\u724c\u5b50\u597d\uff1f<\/strong>\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5148\u4e0d\u56de\u7b54\u54c1\u724c\uff0c\u5148\u7ed9\u5224\u65ad\u6807\u51c6<\/strong>\uff1a\u201c\u9009\u4ec0\u4e48\u4e0d\u53d6\u51b3\u4e8e\u54c1\u724c\uff0c\u53d6\u51b3\u4e8e\u60a8\u5bb6XX\u9700\u6c42\u201d\u3002\u7136\u540e\u95ee\u5ba2\u6237\uff1a\u201c\u60a8\u662f\u5426\u4e86\u89e3\u8fc7\u9505\u7089\u7684\u2018\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u2019\u8fd9\u4e2a\u6982\u5ff5\uff1f\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>04-IS-004<\/strong>\uff1a\u5ba2\u6237\u95ee\u54c1\u724c\u65f6\u7684\u7d27\u6025\u5904\u7f6e<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c<strong>\u51b7\u51dd\u7089\u662f\u4e0d\u662f\u6bd4\u666e\u901a\u7089\u597d\uff1f<\/strong>\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u89e3\u91ca\u524d\u63d0\u6761\u4ef6<\/strong>\uff1a\u201c\u51b7\u51dd\u7089\u786e\u5b9e\u6548\u7387\u66f4\u9ad8\uff0c\u4f46\u5fc5\u987b\u914d\u5408\u4f4e\u6e29\u5730\u6696\u7cfb\u7edf\uff08\u6c34\u6e29\u226455\u2103\uff09\uff0c\u5426\u5219\u4f18\u52bf\u65e0\u6cd5\u53d1\u6325\u3002\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3.3\u8282<\/strong>\uff1a\u5e38\u89c4\u7089 vs \u51b7\u51dd\u7089<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c<strong>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u548c\u9505\u7089\u5730\u6696\u54ea\u4e2a\u597d\uff1f<\/strong>\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u63d0\u4f9b\u591a\u65b9\u6848\u5bf9\u6bd4<\/strong>\uff1a\u201c\u4e24\u79cd\u65b9\u6848\u5404\u6709\u4f18\u52a3\uff0c\u6211\u4eec\u53ef\u4ee5\u4ece\u521d\u6295\u8d44\u300120\u5e74\u8fd0\u884c\u8d39\u7528\u3001\u8212\u9002\u5ea6\u3001\u7ef4\u62a4\u4fbf\u5229\u6027\u7b49\u51e0\u4e2a\u7ef4\u5ea6\u5e2e\u60a8\u5bf9\u6bd4\u3002\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>2.4\u8282<\/strong>\uff1a\u7528\u6237\u5e38\u89c1\u62c5\u5fc3\u4e0e\u6b63\u786e\u5e94\u5bf9\u7b56\u7565<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c<strong>\u6211\u542c\u8bf4\u7a7a\u6c14\u80fd\u5f88\u7701\u7535\uff0c\u662f\u4e0d\u662f\u771f\u7684\uff1f<\/strong>\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f15\u7528\u5177\u4f53\u6570\u636e<\/strong>\uff1a\u201c\u662f\u7684\uff0c\u5728\u7406\u60f3\u5de5\u51b5\u4e0b\uff0c\u7a7a\u6c14\u80fd\u7684\u80fd\u6548\u6bd4\uff08COP\uff09\u53ef\u8fbe3-4\uff0c\u610f\u5473\u7740\u75281\u5ea6\u7535\u53ef\u4ee5\u642c\u8fd03-4\u5ea6\u70ed\u91cf\u3002\u76f8\u6bd4\u71c3\u6c14\u9505\u7089\uff0c\u8fd0\u884c\u8d39\u7528\u80fd\u8282\u770140%-60%\u3002\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3.4\u8282<\/strong>\uff1a\u7a7a\u6c14\u80fd\u70ed\u6cf5\u7cfb\u7edf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c<strong>\u7279\u7075\u3001\u7ea6\u514b\u3001\u5f00\u5229\u8fd9\u4e9b\u54c1\u724c\u600e\u4e48\u6837\uff1f<\/strong>\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u533a\u5206\u7cfb\u7edf\u7c7b\u578b<\/strong>\uff1a\u201c\u8fd9\u4e9b\u662f\u7f8e\u56fd\u54c1\u724c\uff0c\u4e3b\u8981\u505a\u6c34\u7cfb\u7edf\uff08\u7a7a\u8c03+\u5730\u6696\u4e00\u4f53\uff09\u3002\u5982\u679c\u60a8\u8ffd\u6c42\u51fa\u98ce\u67d4\u548c\u3001\u5730\u6696\u8282\u80fd\uff0c\u5b83\u4eec\u662f\u5f88\u597d\u7684\u9009\u62e9\u3002\u4f46\u4e5f\u8981\u6ce8\u610f\uff0c\u6c34\u7cfb\u7edf\u5bf9\u5b89\u88c5\u548c\u552e\u540e\u8981\u6c42\u66f4\u9ad8\u3002\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9700\u5f15\u7528\u300a\u6237\u5f0f\u6c34\u7cfb\u7edf\u54c1\u724c\u5bf9\u6bd4.pdf\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u201c<strong>\u53d1\u70ed\u7535\u7f06\u548c\u7535\u70ed\u819c\u54ea\u4e2a\u597d\uff1f<\/strong>\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6839\u636e\u573a\u666f\u63a8\u8350<\/strong>\uff1a\u201c\u7535\u70ed\u819c\u53d1\u70ed\u5747\u5300\u3001\u5347\u6e29\u5feb\uff1b\u53d1\u70ed\u7535\u7f06\u94fa\u8bbe\u7075\u6d3b\u3001\u66f4\u5b89\u5168\u3002\u603b\u7684\u6765\u8bf4\uff0c\u53d1\u70ed\u7535\u7f06\u66f4\u6210\u719f\u7a33\u5b9a\uff0c\u662f\u7535\u80fd\u91c7\u6696\u7684\u9996\u9009\u3002\u201d<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>3.5\u8282<\/strong>\uff1a\u7535\u80fd\u91c7\u6696\u7cfb\u7edf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">5.4 \u8bbe\u8ba1\u89c4\u8303\u2014\u2014\u56fd\u5bb6\u6807\u51c6\u4e0e\u9009\u578b\u516c\u5f0f<\/h3>\n\n<h4 class=\"wp-block-heading\">5.4.1 \u6838\u5fc3\u6807\u51c6\u4e00\u89c8<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6807\u51c6\u53f7<\/th><th>\u540d\u79f0<\/th><th>\u6838\u5fc3\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>GB50736-2012<\/td><td>\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td><td>\u4f9b\u6696\u70ed\u8d1f\u8377\u8ba1\u7b97\u3001\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea6<\/td><\/tr><tr><td>JGJ 142-2012<\/td><td>\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td><td>\u5730\u6696\u76d8\u7ba1\u95f4\u8ddd\/\u957f\u5ea6\/\u6c34\u6e29\/\u538b\u529b<\/td><\/tr><tr><td>GB50242-2002<\/td><td>\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303<\/td><td>\u6253\u538b\u9a8c\u6536\u6807\u51c6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">5.4.2 \u70ed\u8d1f\u8377\u8ba1\u7b97\u2014\u2014\u9009\u578b\u7b2c\u4e00\u6b65<\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/strong>\uff1a\u6839\u636e GB 50736-2012 \u7b2c5.2.1\u6761\uff0c\u5fc5\u987b\u5bf9\u6bcf\u4e2a\u623f\u95f4\u8fdb\u884c\u9010\u9879\u70ed\u8d1f\u8377\u8ba1\u7b97\uff0c\u4e0d\u5f97\u4ee5\u4f30\u7b97\u503c\u66ff\u4ee3\u3002\u5404\u623f\u95f4\u70ed\u8d1f\u8377\u5dee\u5f02\u76f4\u63a5\u5f71\u54cd\u76d8\u7ba1\u95f4\u8ddd\u548c\u56de\u8def\u5206\u914d\uff0c\u8df3\u8fc7\u8fd9\u4e00\u6b65\u662f\u5730\u6696\u4e0d\u70ed\u7684\u6839\u6e90\u4e4b\u4e00\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5efa\u7b51\u7c7b\u578b<\/th><th>\u8bbe\u8ba1\u70ed\u8d1f\u8377<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u8282\u80fd\u5efa\u7b51\uff08\u6709\u4fdd\u6e29\uff09<\/td><td>80-100W\/\u33a1<\/td><td>\u6ee1\u8db3\u6700\u51b7\u5929\u9700\u6c42<\/td><\/tr><tr><td>\u666e\u901a\u5efa\u7b51\uff08\u65e0\u4fdd\u6e29\uff09<\/td><td>100-120W\/\u33a1<\/td><td>\u6ee1\u8db3\u6700\u51b7\u5929\u9700\u6c42<\/td><\/tr><tr><td>\u843d\u5730\u7a97\/\u5927\u9762\u79ef\u73bb\u7483<\/td><td>120-150W\/\u33a1<\/td><td>\u9700\u989d\u5916\u8865\u507f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u8bbe\u8ba1\u903b\u8f91\uff1a\u8bbe\u8ba1\u70ed\u8d1f\u8377\u7528\u4e8e\u8bbe\u5907\u9009\u578b\uff0c\u80fd\u8017\u8d1f\u8377\uff08\u7ea650W\/\u33a1\uff0c\u6574\u4e2a\u91c7\u6696\u5b63\u5e73\u5747\u503c\uff09\u7528\u4e8e\u8d39\u7528\u4f30\u7b97\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u9009\u578b\u516c\u5f0f\uff1a<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><code>\u70ed\u6e90\u529f\u7387(kW) = \u91c7\u6696\u9762\u79ef(\u33a1) \u00d7 \u8bbe\u8ba1\u70ed\u8d1f\u8377(W\/\u33a1) \u00f7 1000 \u00d7 \u5b89\u5168\u7cfb\u6570(1.1-1.2)<\/code><\/p>\n\n<p class=\"wp-block-paragraph\">\u8ba1\u7b97\u793a\u4f8b\uff1a120\u33a1\u8282\u80fd\u5efa\u7b51<br>120\u33a1 \u00d7 90W\/\u33a1 \u00f7 1000 \u00d7 1.15 = 12.4kW \u2192 \u900914-16kW\u58c1\u6302\u7089\u6216\u5bf9\u5e94\u7684\u7a7a\u6c14\u80fd\u4e3b\u673a<\/p>\n\n<h4 class=\"wp-block-heading\">5.4.3 \u5730\u6696\u8bbe\u8ba1\u6838\u5fc3\u53c2\u6570<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6807\u51c6\u503c<\/th><th>\u8212\u9002\/\u9ad8\u6548\u533a\u95f4<\/th><th>\u4f9d\u636e<\/th><\/tr><\/thead><tbody><tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>\u226460\u2103<\/td><td>35-45\u2103\uff08\u4f4e\u6e29\u9ad8\u6548\uff09<\/td><td>JGJ 142-2012<\/td><\/tr><tr><td>\u4f9b\u56de\u6c34\u6e29\u5dee<\/td><td>5-10\u2103<\/td><td>8-10\u2103<\/td><td>\u2014<\/td><\/tr><tr><td>\u5730\u9762\u6e29\u5ea6<\/td><td>\u226429\u2103\uff08\u4eba\u5458\u957f\u671f\u505c\u7559\u533a\uff09<\/td><td>24-26\u2103\uff08\u8212\u9002\u533a\u95f4\uff09<\/td><td>JGJ 142-2012 \u7b2c3.1.3\u6761<\/td><\/tr><tr><td>\u5ba4\u5185\u8bbe\u8ba1\u6e29\u5ea6<\/td><td>\u2014<\/td><td>18-22\u2103\uff08\u5367\u5ba420\u2103\uff0c\u5ba2\u538518\u2103\uff09<\/td><td>\u2014<\/td><\/tr><tr><td>\u6c34\u6d41\u901f\u5ea6<\/td><td>\u22650.25m\/s\uff08\u6392\u9664\u7a7a\u6c14\uff09<\/td><td>0.3-0.5m\/s<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u5730\u9762\u5e73\u5747\u6e29\u5ea6\u6821\u6838\u516c\u5f0f\uff08JGJ 142-2012 \u6761\u6587\u8bf4\u660e\uff09\uff1a<\/p>\n\n<p class=\"wp-block-paragraph\"><code>tpj = tn + 9.82 \u00d7 (q\/100)^0.969<\/code><\/p>\n\n<p class=\"wp-block-paragraph\">\uff08tpj=\u5730\u9762\u5e73\u5747\u6e29\u5ea6\u2103\uff1btn=\u5ba4\u5185\u8ba1\u7b97\u6e29\u5ea6\u2103\uff1bq=\u5355\u4f4d\u9762\u79ef\u6563\u70ed\u91cfW\/\u33a1\uff09<\/p>\n\n<p class=\"wp-block-paragraph\">\u4fdd\u6e29\u5c42\u70ed\u963b\u8d8a\u5927\uff08\u5411\u4e0b\u70ed\u635f\u5931\u8d8a\u5c0f\uff09\uff0c\u76f8\u540c\u4f9b\u6c34\u6e29\u5ea6\u4e0b\u4f20\u7ed9\u623f\u95f4\u7684\u6709\u6548\u70ed\u91cf\u8d8a\u9ad8\u3002\u52a3\u8d28\u4fdd\u6e29\u677f\u5bfc\u81f4\u5411\u4e0b\u70ed\u635f\u5931\u8d8530%\uff0c\u4f9b\u6696\u8d39\u51ed\u7a7a\u4e0a\u6da8\u3002<\/p>\n\n<h4 class=\"wp-block-heading\">5.4.4 \u6253\u538b\u9a8c\u6536\u6807\u51c6<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u6807\u51c6<\/th><th>\u4f9d\u636e<\/th><\/tr><\/thead><tbody><tr><td>\u6253\u538b\u538b\u529b<\/td><td>0.6MPa\uff086\u516c\u65a4\uff09<\/td><td>GB50242-2002<\/td><\/tr><tr><td>\u7a33\u538b\u65f6\u95f4<\/td><td>\u22651\u5c0f\u65f6<\/td><td>\u2014<\/td><\/tr><tr><td>\u5141\u8bb8\u538b\u964d<\/td><td>\u22640.05MPa\uff080.5\u516c\u65a4\uff09<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">5.4.5 \u88c5\u4fee\u5404\u9636\u6bb5\u5173\u952e\u8282\u70b9<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u88c5\u4fee\u9636\u6bb5<\/th><th>\u5173\u952e\u52a8\u4f5c<\/th><\/tr><\/thead><tbody><tr><td>\u6c34\u7535\u6539\u9020\u524d<\/td><td>\u786e\u5b9a\u5730\u6696\u65b9\u6848\uff08\u70ed\u6e90\u7c7b\u578b\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u3001\u6e29\u63a7\u5668\u5e03\u7ebf\uff09<\/td><\/tr><tr><td>\u6c34\u7535\u6539\u9020\u4e2d<\/td><td>\u9884\u57cb\u6e29\u63a7\u5668\u4fe1\u53f7\u7ebf\uff08\u8054\u52a8\u63a7\u5236\uff09\u3001\u9884\u7559\u5206\u96c6\u6c34\u5668\u7535\u6e90<\/td><\/tr><tr><td>\u5730\u6696\u94fa\u8bbe<\/td><td>\u4fdd\u6e29\u677f\u2192\u53cd\u5c04\u819c\u2192\u76d8\u7ba1\u94fa\u8bbe\uff08\u95f4\u8ddd\u6309\u8bbe\u8ba1\uff09\u2192\u6253\u538b\u6d4b\u8bd5\u2192\u56de\u586b<\/td><\/tr><tr><td>\u5730\u9762\u627e\u5e73\u524d<\/td><td>\u786e\u8ba4\u6253\u538b\u5408\u683c\uff08\u4fdd\u538b24h\u65e0\u538b\u964d\uff09<\/td><\/tr><tr><td>\u5730\u9762\u6750\u6599\u5b89\u88c5<\/td><td>\u74f7\u7816\/\u5730\u677f\u94fa\u8bbe\u524d\u518d\u6b21\u786e\u8ba4\u7cfb\u7edf\u538b\u529b<\/td><\/tr><tr><td>\u5165\u4f4f\u524d<\/td><td>\u7cfb\u7edf\u8c03\u8bd5\u3001\u5730\u6696\u9996\u6b21\u5347\u6e29\u6d4b\u8bd5\uff08\u9010\u65e5\u5347\u6e295\u2103\uff0c\u907f\u514d\u56de\u586b\u5c42\u5f00\u88c2\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f \u91cd\u8981\u63d0\u9192\uff1a\u88c5\u4fee\u5b8c\u6210\u540e\u60f3\u52a0\u88c5\u5730\u6696\u6781\u5176\u56f0\u96be\uff0c\u9700\u7834\u574f\u5730\u9762\u91cd\u65b0\u94fa\u8bbe\u3002\u5fc5\u987b\u5728\u6c34\u7535\u6539\u9020\u9636\u6bb5\u4e00\u6b21\u6027\u89c4\u5212\u5230\u4f4d\u3002<\/p>\n<\/blockquote>\n\n<h3 class=\"wp-block-heading\">5.5 \u5730\u6696\u65bd\u5de5\u4e0e\u9a8c\u6536\u89c4\u8303<\/h3>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4f9d\u636e\u6807\u51c6\uff1aGB50242-2002\u300a\u5efa\u7b51\u7ed9\u6c34\u6392\u6c34\u53ca\u91c7\u6696\u5de5\u7a0b\u65bd\u5de5\u8d28\u91cf\u9a8c\u6536\u89c4\u8303\u300b\u3001JGJ 142-2012\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b\u300112K404\u300a\u5730\u9762\u8f90\u5c04\u4f9b\u6696\u7cfb\u7edf\u65bd\u5de5\u5b89\u88c5\u300b<\/p>\n<\/blockquote>\n\n<h4 class=\"wp-block-heading\">5.5.1\u3001\u65bd\u5de5\u524d\u89c4\u5212\uff08\u88c5\u4fee\u6c34\u7535\u9636\u6bb5\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9636\u6bb5<\/th><th>\u64cd\u4f5c\u8981\u6c42<\/th><th>\u81f4\u547d\u63d0\u9192<\/th><\/tr><\/thead><tbody><tr><td>\u6c34\u7535\u6539\u9020\u524d<\/td><td>\u786e\u5b9a\u5730\u6696\u65b9\u6848\uff1a\u660e\u786e\u70ed\u6e90\u7c7b\u578b\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u3001\u6e29\u63a7\u5668\u5e03\u7ebf<\/td><td>\u88c5\u4fee\u5b8c\u6210\u540e\u60f3\u52a0\u88c5\u6c34\u5730\u6696\u9700\u7834\u574f\u5730\u9762\u91cd\u65b0\u94fa\u8bbe\uff0c<strong>\u5fc5\u987b\u5728\u6c34\u7535\u6539\u9020\u9636\u6bb5\u4e00\u6b21\u6027\u89c4\u5212\u5230\u4f4d<\/strong><\/td><\/tr><tr><td>\u6c34\u7535\u6539\u9020\u4e2d<\/td><td>\u9884\u57cb\u6e29\u63a7\u5668\u4fe1\u53f7\u7ebf\uff08\u7528\u4e8e\u8054\u52a8\u63a7\u5236\uff09\u3001\u9884\u7559\u5206\u96c6\u6c34\u5668\u7535\u6e90<\/td><td>\u4fe1\u53f7\u7ebf\u9700\u9884\u7559\u8db3\u591f\u957f\u5ea6\uff0c\u907f\u514d\u540e\u671f\u63a5\u7ebf\u4e0d\u8db3\uff1b\u6f0f\u57cb\u4fe1\u53f7\u7ebf=\u8054\u52a8\u63a7\u5236\u65e0\u6cd5\u5b9e\u73b0=\u957f\u671f\"\u76f2\u76ee\u70e7\"<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">5.5.2\u3001\u5730\u6696\u94fa\u8bbe\u65bd\u5de5\uff08\u6838\u5fc3\u5b89\u88c5\u73af\u8282\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u94fa\u8bbe\u987a\u5e8f\uff1a<\/strong>&nbsp;<code>\u4fdd\u6e29\u677f \u2192 \u53cd\u5c04\u819c \u2192 \u76d8\u7ba1\u94fa\u8bbe\uff08\u95f4\u8ddd\u6309\u8bbe\u8ba1\uff09\u2192 \u6253\u538b\u6d4b\u8bd5 \u2192 \u56de\u586b<\/code><\/p>\n\n<h5 class=\"wp-block-heading\">5.5.2.1 \u4fdd\u6e29\u5c42\u4e0e\u53cd\u5c04\u819c<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ec4\u4ef6<\/th><th>\u8981\u6c42<\/th><th>\u5e38\u89c1\u5077\u5de5\u51cf\u6599<\/th><\/tr><\/thead><tbody><tr><td>\u4fdd\u6e29\u677f<\/td><td>\u4f18\u5148\u9009\u5e26\u68c0\u6d4b\u62a5\u544a\u7684\u5408\u89c4\u4ea7\u54c1\uff1b\u539a\u5ea6\u226520mm\uff08\u5e38\u89c4\uff09\u3001\u226530mm\uff08\u522b\u5885\/\u5e95\u5c42\uff09<\/td><td>\u7528\u52a3\u8d28\u6ce1\u6cab\u677f\u66ff\u4ee3\uff0c3-5\u5e74\u540e\u7c89\u5316\u584c\u9677\uff0c\u5411\u4e0b\u70ed\u635f\u5931\u8d8530%<\/td><\/tr><tr><td>\u53cd\u5c04\u819c<\/td><td>\u63a8\u8350\u5168\u94dd\u53cd\u5c04\u819c\uff0c\u53cd\u5c04\u7387\u226590%<\/td><td>\u7528\u9540\u94dd\u819c\u66ff\u4ee3\uff0c2-3\u5e74\u540e\u94dd\u5c42\u6c27\u5316\u8131\u843d\uff0c\u53cd\u5c04\u7387\u964d\u81f330%\u4ee5\u4e0b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\">5.5.2.2 \u76d8\u7ba1\u94fa\u8bbe\u6807\u51c6\uff08\u4f9d\u636eJGJ 142-2012\uff09<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53c2\u6570<\/th><th>\u6807\u51c6\u8981\u6c42<\/th><th>\u5e38\u89c1\u95ee\u9898<\/th><\/tr><\/thead><tbody><tr><td>\u76d8\u7ba1\u95f4\u8ddd<\/td><td>\u5e38\u89c4\u533a\u57df15-20cm\uff1b\u536b\u751f\u95f4\/\u9760\u5916\u5899\u533a\u57df10-15cm<\/td><td>\u95f4\u8ddd\u8fc7\u5927\u2192\u5c40\u90e8\u4e0d\u70ed\uff1b\u95f4\u8ddd\u8fc7\u5c0f\u2192\u6210\u672c\u5347\u9ad8\u3001\u6c34\u6d41\u963b\u529b\u589e\u5927<\/td><\/tr><tr><td>\u5355\u56de\u8def\u6700\u5927\u957f\u5ea6<\/td><td>De16\u7ba1\u2264120m\uff1bDe20\u7ba1\u2264150m<\/td><td>\u8d85\u957f\u2192\u6c34\u529b\u963b\u529b\u8fc7\u5927\uff0c\u8fdc\u7aef\u652f\u8def\u4e0d\u70ed<\/td><\/tr><tr><td>\u6bcf\u56de\u8def\u8986\u76d6\u9762\u79ef<\/td><td>\u7ea612-18\u33a1<\/td><td>\u4e00\u4e2a\u623f\u95f4\u53ef\u8bbe\u4e00\u4e2a\u56de\u8def\uff0c\u5927\u7a7a\u95f4\u9700\u591a\u56de\u8def\u5e76\u8054<\/td><\/tr><tr><td>\u76d8\u7ba1\u5f62\u5f0f<\/td><td>\u56de\u5b57\u5f62\uff08\u63a8\u8350\uff09\uff1eS\u5f62<\/td><td>\u56de\u5b57\u5f62\u9ad8\u6e29\u7ba1\u4e0e\u4f4e\u6e29\u7ba1\u95f4\u9694\u6392\u5217\uff0c\u5730\u9762\u6e29\u5ea6\u66f4\u5747\u5300\uff1bS\u5f62\u6613\u51fa\u73b0\u5c40\u90e8\u51b7\u70ed\u4e0d\u5747<\/td><\/tr><tr><td>\u8ddd\u5899\u95f4\u8ddd<\/td><td>\u2265100mm<\/td><td>\u8fc7\u8fd1\u2192\u70ed\u91cf\u6cbf\u5899\u4f53\u6563\u5931\uff0c\u751a\u81f3\u5bfc\u81f4\u5899\u4f53\u7ed3\u9732<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\">5.5.2.3 \u8f93\u914d\u7cfb\u7edf\u5b89\u88c5<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ec4\u4ef6<\/th><th>\u89c4\u683c\u8981\u6c42<\/th><th>\u5173\u952e\u8d28\u63a7\u70b9<\/th><\/tr><\/thead><tbody><tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u4f5c\u4e3a\u5206\u914d\u67a2\u7ebd\uff0c\u5c06\u4e3b\u7ba1\u70ed\u6c34\u5206\u914d\u5230\u5404\u623f\u95f4\u652f\u8def\uff0c\u56de\u6c34\u6c47\u96c6<\/td><td>\u6bcf\u5c42\u72ec\u7acb\u5206\u96c6\u6c34\u5668\u9700\u52a0\u88c5\u5c42\u95f4\u5e73\u8861\u9600\uff0c\u907f\u514d\u697c\u4e0a\u70ed\u697c\u4e0b\u51b7\u7684\u5782\u76f4\u6c34\u529b\u5931\u8861<\/td><\/tr><tr><td>\u8f93\u9001\u7ba1\u9053<\/td><td>\u4e3b\u7ba1De25-De32\uff0c\u5730\u6696\u76d8\u7ba1De16-De20<\/td><td>\u51b7\u51dd\u7089\u4f4e\u6e29\u8fd0\u884c\u63a8\u8350<strong>De32\u4e3b\u7ba1+De20\u76d8\u7ba1<\/strong>\uff08\u6d41\u91cf\u5145\u8db3\u963b\u529b\u5c0f\uff0c\u7efc\u5408\u8282\u80fd\uff09\uff1b\u4ec530\u33a1\u4ee5\u4e0b\u53ef\u9009De25\u4e3b\u7ba1+De16\u76d8\u7ba1<\/td><\/tr><tr><td>\u5e73\u8861\u9600<\/td><td>\u6bcf\u652f\u8def\u52a0\u88c5\u5e73\u8861\u9600\/\u6d41\u91cf\u8ba1<\/td><td>\u8c03\u8282\u81f3\u8bbe\u8ba1\u6d41\u91cf\uff0c\u89e3\u51b3\u8fd1\u7aef\u8fc7\u70ed\u3001\u8fdc\u7aef\u4e0d\u70ed\u7684\u6c34\u529b\u5931\u8861<\/td><\/tr><tr><td>\u963b\u6c27\u7ba1<\/td><td>\u5fc5\u987b\u4f7f\u7528\u5e26EVOH\u963b\u6c27\u5c42\u7684PERT\/PE-X\u7ba1\uff0c\u6c27\u6c14\u6e17\u900f\u7387\u22640.1g\/m\u00b3\u00b7d\uff08DIN 4726\u6807\u51c6\uff09<\/td><td>\u666e\u901a\u7ba15\u5e74\u540e\u4f20\u70ed\u6548\u7387\u4e0b\u964d30%+\uff0c\u963b\u6c27\u7ba15\u5e74\u540e\u57fa\u672c\u4e0d\u53d8\uff1b5\u5143\u5dee\u4ef7 vs \u6570\u5343\u5143\u6e05\u6d17\u8d39<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">5.5.3\u3001\u56de\u586b\u5c42\u65bd\u5de5\uff08\u84c4\u70ed\u5c42\uff09<\/h4>\n\n<p class=\"wp-block-paragraph\"><strong>\u4f9d\u636e\uff1aJGJ 142-2012<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u6807\u51c6\u8981\u6c42<\/th><th>\u5e38\u89c1\u5077\u5de5\u51cf\u6599<\/th><\/tr><\/thead><tbody><tr><td>\u56de\u586b\u6750\u6599<\/td><td>\u6c34\u6ce5\u7802\u6d46\uff08\u6c34\u6ce5:\u7802\u22481:2.5\uff09+ \u8c46\u77f3\uff08\u589e\u5f3a\u5bfc\u70ed\uff09<\/td><td>\u7528\u7eaf\u6c34\u6ce5\u6216\u7802\u6bd4\u4f8b\u8fc7\u9ad8\u2192\u5bfc\u70ed\u6027\u5dee\u3001\u6613\u5f00\u88c2<\/td><\/tr><tr><td>\u56de\u586b\u539a\u5ea6<\/td><td>\u226550mm\uff0c\u4e14\u8986\u76d6\u76d8\u7ba1\u4e0a\u8868\u9762\u226530mm<\/td><td>\u539a\u5ea6\u4e0d\u8db3\u2192\u76d8\u7ba1\u5916\u9732\u3001\u6563\u70ed\u4e0d\u5747\u3001\u5730\u9762\u6613\u5f00\u88c2<\/td><\/tr><tr><td>\u517b\u62a4\u5468\u671f<\/td><td>\u22657\u5929\uff08\u81ea\u7136\u517b\u62a4\uff0c\u4e0d\u53ef\u5f3a\u5236\u70d8\u5e72\uff09<\/td><td>\u5f3a\u5236\u70d8\u5e72\u2192\u56de\u586b\u5c42\u6536\u7f29\u5f00\u88c2\uff0c\u7834\u574f\u76d8\u7ba1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">\u56de\u586b\u5c42\u4e09\u5927\u4f5c\u7528\uff1a\u4fdd\u62a4\u76d8\u7ba1 + \u5747\u5300\u6563\u70ed + \u84c4\u70ed\u4fdd\u6e29\uff08\u5173\u673a\u540e\u4ecd\u53ef\u6563\u70ed2-3\u5c0f\u65f6\uff09<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">5.5.4\u3001\u6253\u538b\u9a8c\u6536\uff08\u4f9d\u636eGB50242-2002\uff09<\/h4>\n\n<h5 class=\"wp-block-heading\">5.5.4.1 \u9a8c\u6536\u6807\u51c6<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u6807\u51c6\u8981\u6c42<\/th><th>\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u6253\u538b\u538b\u529b<\/td><td><strong>0.6MPa\uff086\u516c\u65a4\uff09<\/strong><\/td><td>\u538b\u529b\u4e0d\u8db3\u65e0\u6cd5\u68c0\u6d4b\u9690\u853d\u6cc4\u6f0f\u70b9\uff1b\u538b\u529b\u8fc7\u9ad8\u53ef\u80fd\u635f\u574f\u76d8\u7ba1<\/td><\/tr><tr><td>\u7a33\u538b\u65f6\u95f4<\/td><td><strong>\u22651\u5c0f\u65f6<\/strong><\/td><td>\u65f6\u95f4\u8fc7\u77ed\u65e0\u6cd5\u53d1\u73b0\u7f13\u6162\u6e17\u6f0f<\/td><\/tr><tr><td>\u5141\u8bb8\u538b\u964d<\/td><td><strong>\u22640.05MPa\uff080.5\u516c\u65a4\uff09<\/strong><\/td><td>\u538b\u964d\u8d85\u6807\u8bf4\u660e\u7ba1\u8def\u6cc4\u6f0f\uff0c\u9700\u6392\u67e5\u4fee\u590d\u540e\u91cd\u65b0\u6253\u538b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\">5.5.4.2 \u4e09\u6b21\u6253\u538b\u8282\u70b9\uff08\u7f3a\u4e00\u4e0d\u53ef\uff09<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6253\u538b\u8282\u70b9<\/th><th>\u76ee\u7684<\/th><th>\u5408\u683c\u6807\u51c6<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c\u4e00\u6b21\uff1a\u76d8\u7ba1\u94fa\u8bbe\u5b8c\u6210\u540e\u3001\u56de\u586b\u524d<\/td><td>\u68c0\u6d4b\u7ba1\u8def\u672c\u8eab\u53ca\u63a5\u53e3\u662f\u5426\u6cc4\u6f0f<\/td><td>\u7a33\u538b1h\uff0c\u538b\u964d\u22640.05MPa\uff0c\u65b9\u53ef\u56de\u586b<\/td><\/tr><tr><td>\u7b2c\u4e8c\u6b21\uff1a\u56de\u586b\u5b8c\u6210\u3001\u5730\u9762\u627e\u5e73\u524d<\/td><td>\u786e\u8ba4\u56de\u586b\u65bd\u5de5\u672a\u7834\u574f\u7ba1\u8def<\/td><td><strong>\u4fdd\u538b24h\u65e0\u538b\u964d<\/strong><\/td><\/tr><tr><td>\u7b2c\u4e09\u6b21\uff1a\u5730\u9762\u6750\u6599\uff08\u74f7\u7816\/\u5730\u677f\uff09\u5b89\u88c5\u524d<\/td><td>\u786e\u8ba4\u540e\u7eed\u65bd\u5de5\u672a\u635f\u4f24\u7ba1\u8def<\/td><td>\u7a33\u538b1h\uff0c\u538b\u964d\u22640.05MPa<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f \u4e09\u6b21\u6253\u538b\u6bcf\u6b21\u90fd\u9700\u62cd\u7167\u5b58\u6863\u538b\u529b\u8868\u8bfb\u6570\uff0c\u4f5c\u4e3a\u9a8c\u6536\u51ed\u8bc1\u548c\u65e5\u540e\u7ef4\u62a4\u4f9d\u636e\u3002<\/p>\n<\/blockquote>\n\n<h4 class=\"wp-block-heading\">5.5.5\u3001\u53d1\u70ed\u7535\u7f06\u4e13\u9879\u65bd\u5de5\u4e0e\u9a8c\u6536\uff08\u4f9d\u636e12K404\uff09<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9a8c\u6536\u9879<\/th><th>\u6807\u51c6\u8981\u6c42<\/th><th>\u98ce\u9669\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\u7edd\u7f18\u6d4b\u8bd5<\/td><td>\u5b89\u88c5\u5b8c\u6210\u540e\u5fc5\u987b\u505a\u7edd\u7f18\u6d4b\u8bd5\uff0c\u7535\u963b\u503c\u7b26\u5408\u4ea7\u54c1\u8981\u6c42<\/td><td>\u7edd\u7f18\u4e0d\u8fbe\u6807<strong>\u4e25\u7981\u901a\u7535<\/strong>\uff0c\u5426\u5219\u6f0f\u7535\u4e8b\u6545<\/td><\/tr><tr><td>\u51b7\u70ed\u7ebf\u63a5\u5934\u4f4d\u7f6e<\/td><td>\u51b7\u3001\u70ed\u63a5\u5934\u5fc5\u987b\u57cb\u5728\u8ddd\u79bb\u63a5\u7ebf\u76d2300-500mm\u8303\u56f4\u5185\uff0c\u4e25\u7981\u5207\u5272\u6216\u62fc\u63a5\u53d1\u70ed\u4f53<\/td><td>\u63a5\u5934\u4f4d\u7f6e\u9519\u8bef\u6216\u5916\u9732\u2192\u6f0f\u7535\/\u77ed\u8def\u98ce\u9669<\/td><\/tr><tr><td>\u57ab\u5c42\u517b\u62a4\u671f<\/td><td>\u6c34\u6ce5\u7802\u6d46\u57ab\u5c42\u517b\u62a4\u671f\u6ee1\u540e\uff08<strong>\u4e0d\u5c11\u4e8e21\u5929<\/strong>\uff09\u65b9\u53ef\u901a\u7535\u8c03\u8bd5<\/td><td>\u8fc7\u65e9\u901a\u7535\u2192\u56de\u586b\u5c42\u5f00\u88c2\uff0c\u7535\u7f06\u8fc7\u70ed\u635f\u574f<\/td><\/tr><tr><td>\u8c03\u8bd5\u6d41\u7a0b<\/td><td>\u540c\u65f6\u901a\u75356-8\u5c0f\u65f6\u540e\uff0c\u68c0\u6d4b\u5730\u9762\u6e29\u5ea6\u662f\u5426\u572824-26\u2103\u4e3a\u5b9c<\/td><td>\u8df3\u8fc7\u8c03\u8bd5\u2192\u5b9e\u9645\u4f9b\u6696\u6548\u679c\u65e0\u6cd5\u9a8c\u8bc1<\/td><\/tr><tr><td>\u95f4\u8ddd\u4e00\u81f4\u6027<\/td><td>\u6309\u8bbe\u8ba1\u95f4\u8ddd\u94fa\u8bbe\uff0c\u504f\u5dee\u2264\u00b110mm<\/td><td>\u95f4\u8ddd\u4e0d\u5747\u2192\u5c40\u90e8\u8fc7\u70ed\u6216\u4f4e\u6e29<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u7535\u70ed\u819c\u5b89\u5168\u8d28\u63a7\uff1a<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u98ce\u9669\u70b9<\/th><th>\u540e\u679c<\/th><th>\u8d28\u63a7\u63aa\u65bd<\/th><\/tr><\/thead><tbody><tr><td>\u9897\u7c92\u55b7\u6d82\u4e0d\u5747\u5300<\/td><td>\u5c40\u90e8\u7535\u963b\u8fc7\u9ad8\/\u8fc7\u4f4e\u2192\u5c40\u90e8\u8fc7\u70ed\u5f15\u71c3<\/td><td>\u9009\u7528\u6b63\u89c4\u54c1\u724c\uff0c\u8fdb\u573a\u524d\u505a\u7535\u963b\u62bd\u68c0<\/td><\/tr><tr><td>\u8f7d\u4f53\u8d28\u91cf\u5dee<\/td><td>\u5bfc\u7535\u6750\u6599\u8131\u843d\u5f62\u6210\u65b0\u901a\u8def\u2192\u77ed\u8def\u6216\u6f0f\u7535<\/td><td>\u7981\u6b62\u4f7f\u7528\u65e0\u54c1\u724c\u3001\u65e0\u68c0\u6d4b\u62a5\u544a\u7684\u4ea7\u54c1<\/td><\/tr><tr><td>\u63a5\u5934\u8fc7\u591a<\/td><td>\u6bcf\u4e2a\u63a5\u5934\u90fd\u662f\u6f5c\u5728\u6545\u969c\u70b9\u2192\u6253\u706b\u3001\u6f0f\u7535<\/td><td>\u5c3d\u91cf\u9009\u7528\u6574\u5f20\u819c\u51cf\u5c11\u62fc\u63a5\uff1b\u63a5\u5934\u9700\u505a\u7edd\u7f18\u9632\u6c34\u5904\u7406<\/td><\/tr><tr><td>\u6563\u70ed\u4e0d\u826f<\/td><td>\u88ab\u5bb6\u5177\u8986\u76d6\u540e\u70ed\u91cf\u79ef\u805a\u2192\u6e29\u5ea6\u6301\u7eed\u5347\u9ad8\u5f15\u71c3\u53ef\u71c3\u7269<\/td><td>\u5b89\u88c5\u524d\u6807\u6ce8\u53d1\u70ed\u533a\u57df\uff0c<strong>\u7981\u6b62\u5728\u53d1\u70ed\u533a\u57df\u4e0a\u65b9\u653e\u7f6e\u65e0\u817f\u5bb6\u5177\u3001\u5e8a\u57ab\u7b49\u8986\u76d6\u7269<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">5.5.6\u3001\u7cfb\u7edf\u8c03\u8bd5\u4e0e\u9996\u6b21\u4f7f\u7528<\/h4>\n\n<h5 class=\"wp-block-heading\">5.5.6.1 \u6ce8\u6c34\u6392\u6c14<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6b65\u9aa4<\/th><th>\u64cd\u4f5c<\/th><th>\u5173\u952e\u53c2\u6570<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>\u6253\u5f00\u5404\u652f\u8def\u9600\u95e8\uff0c\u542f\u52a8\u5faa\u73af\u6cf5<\/td><td>\u2014<\/td><\/tr><tr><td>2<\/td><td>\u9010\u4e2a\u652f\u8def\u6392\u6c14\u81f3\u51fa\u6c34\u8fde\u7eed\u65e0\u6c14\u6ce1<\/td><td>\u6c34\u6d41\u901f\u5ea6\u9700\u22650.25m\/s\u624d\u80fd\u6709\u6548\u6392\u9664\u7a7a\u6c14<\/td><\/tr><tr><td>3<\/td><td>\u786e\u8ba4\u7cfb\u7edf\u538b\u529b\u57280.15-0.25MPa\uff081.5-2.5\u516c\u65a4\uff09<\/td><td>\u538b\u529b\u8fc7\u4f4e\u9700\u8865\u6c34\uff0c\u8fc7\u9ad8\u9700\u6cc4\u538b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u6392\u6c14\u4e0d\u5f7b\u5e95\u2192\u6c14\u5835\u2192\u5faa\u73af\u4e0d\u7545\u2192\u5c40\u90e8\u4e0d\u70ed\uff0c\u8fd9\u662f\u65b0\u88c5\u7cfb\u7edf\u6700\u5e38\u89c1\u7684\u8c03\u8bd5\u95ee\u9898\u3002<\/p>\n<\/blockquote>\n\n<h5 class=\"wp-block-heading\">5.5.6.2 \u9996\u6b21\u5347\u6e29\uff08\u4e25\u7981\u76f4\u63a5\u5f00\u6700\u9ad8\u6e29\uff01\uff09<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5929\u6570<\/th><th>\u4f9b\u6c34\u6e29\u5ea6\u8bbe\u5b9a<\/th><th>\u76ee\u7684<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c1\u5929<\/td><td>30\u2103<\/td><td>\u6e29\u548c\u9884\u70ed\u56de\u586b\u5c42<\/td><\/tr><tr><td>\u7b2c2\u5929<\/td><td>35\u2103<\/td><td>\u9010\u65e5\u5347\u6e29<\/td><\/tr><tr><td>\u7b2c3\u5929<\/td><td>40\u2103<\/td><td>\u9010\u65e5\u5347\u6e29<\/td><\/tr><tr><td>\u7b2c4\u5929<\/td><td>45\u2103<\/td><td>\u63a5\u8fd1\u76ee\u6807\u6e29\u5ea6<\/td><\/tr><tr><td>\u7b2c5\u5929\u8d77<\/td><td>45\u2103\uff08\u7ef4\u6301\uff09<\/td><td>\u7a33\u5b9a\u8fd0\u884c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u26a0\ufe0f \u4e25\u7981\u9996\u6b21\u76f4\u63a5\u8bbe\u5b9a45\u2103\u4ee5\u4e0a\uff0c\u5347\u6e29\u8fc7\u5feb\u4f1a\u5bfc\u81f4\u56de\u586b\u5c42\u5f00\u88c2\uff0c\u4e0d\u53ef\u9006\u3002<\/p>\n<\/blockquote>\n\n<h5 class=\"wp-block-heading\">5.5.6.3 \u6e29\u63a7\u5668\u8bbe\u5b9a<\/h5>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u623f\u95f4<\/th><th>\u63a8\u8350\u8bbe\u5b9a\u6e29\u5ea6<\/th><th>\u5730\u9762\u6e29\u5ea6\u4e0a\u9650<\/th><\/tr><\/thead><tbody><tr><td>\u5367\u5ba4<\/td><td>20-22\u2103<\/td><td>\u226429\u2103<\/td><\/tr><tr><td>\u5ba2\u5385<\/td><td>18-20\u2103<\/td><td>\u226429\u2103<\/td><\/tr><tr><td>\u536b\u751f\u95f4<\/td><td>22-24\u2103<\/td><td>\u226433\u2103\uff08JGJ 142-2012\uff0c\u77ed\u671f\u505c\u7559\u533a\u53ef\u653e\u5bbd\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h5 class=\"wp-block-heading\">5.5.6.4 \u8054\u52a8\u63a7\u5236\u8c03\u8bd5<\/h5>\n\n<p class=\"wp-block-paragraph\">\u786e\u8ba4\u6e29\u63a7\u5668\u4e0e\u70ed\u6e90\uff08\u9505\u7089\/\u70ed\u6cf5\uff09\u8054\u52a8\u6b63\u5e38\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u5168\u5c4b\u8fbe\u6807 \u2192 \u70ed\u6e90\u81ea\u52a8\u964d\u529f\u7387\u6216\u505c\u673a<\/li>\n\n<li>\u4efb\u4e00\u623f\u95f4\u4f4e\u4e8e\u8bbe\u5b9a \u2192 \u70ed\u6e90\u81ea\u52a8\u542f\u52a8<\/li>\n<\/ul>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u672a\u8054\u52a8 = \"\u76f2\u76ee\u70e7\"\uff0c\u8fd0\u884c\u8d39\u7528\u5347\u9ad820-30%\uff0c\u5ba4\u6e29\u6ce2\u52a8\u5927\u3002<\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">5.5.7\u3001\u65bd\u5de5\u5168\u6d41\u7a0b\u8d28\u63a7\u6e05\u5355<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5de5\u5e8f<\/th><th>\u8d28\u63a7\u8981\u70b9<\/th><th>\u9a8c\u6536\u51ed\u8bc1<\/th><\/tr><\/thead><tbody><tr><td>\u2460 \u4fdd\u6e29\u677f\u94fa\u8bbe<\/td><td>\u539a\u5ea6\u8fbe\u6807\u3001\u65e0\u7a7a\u6d1e\u7fd8\u8fb9<\/td><td>\u73b0\u573a\u62cd\u7167<\/td><\/tr><tr><td>\u2461 \u53cd\u5c04\u819c\u94fa\u8bbe<\/td><td>\u5168\u94dd\u53cd\u5c04\u819c\u3001\u63a5\u7f1d\u5904\u642d\u63a5\u226550mm<\/td><td>\u73b0\u573a\u62cd\u7167<\/td><\/tr><tr><td>\u2462 \u76d8\u7ba1\u94fa\u8bbe<\/td><td>\u95f4\u8ddd\/\u56de\u8def\u957f\u5ea6\/\u76d8\u7ba1\u5f62\u5f0f\/\u8ddd\u5899\u95f4\u8ddd\u7b26\u5408\u8bbe\u8ba1<\/td><td>\u73b0\u573a\u5168\u666f\u7167 + \u95f4\u8ddd\u62bd\u68c0\u8bb0\u5f55<\/td><\/tr><tr><td>\u2463 \u7b2c\u4e00\u6b21\u6253\u538b<\/td><td>0.6MPa\u7a33\u538b\u22651h\uff0c\u538b\u964d\u22640.05MPa<\/td><td><strong>\u538b\u529b\u8868\u8bfb\u6570\u7167\u7247 + \u7b7e\u5b57\u786e\u8ba4<\/strong><\/td><\/tr><tr><td>\u2464 \u5206\u96c6\u6c34\u5668\u5b89\u88c5<\/td><td>\u6bcf\u652f\u8def\u5e73\u8861\u9600\/\u6d41\u91cf\u8ba1\u5c31\u4f4d<\/td><td>\u73b0\u573a\u62cd\u7167<\/td><\/tr><tr><td>\u2465 \u56de\u586b\u65bd\u5de5<\/td><td>\u6750\u6599\/\u539a\u5ea6\/\u517b\u62a4\u671f\u8fbe\u6807<\/td><td>\u6750\u6599\u914d\u6bd4\u7167\u7247<\/td><\/tr><tr><td>\u2466 \u7b2c\u4e8c\u6b21\u6253\u538b<\/td><td>\u4fdd\u538b24h\u65e0\u538b\u964d<\/td><td><strong>\u538b\u529b\u8868\u8bfb\u6570\u7167\u7247 + \u7b7e\u5b57\u786e\u8ba4<\/strong><\/td><\/tr><tr><td>\u2467 \u5730\u9762\u6750\u6599\u5b89\u88c5\u524d\u7b2c\u4e09\u6b21\u6253\u538b<\/td><td>\u7a33\u538b1h\uff0c\u538b\u964d\u22640.05MPa<\/td><td>\u538b\u529b\u8868\u8bfb\u6570\u7167\u7247<\/td><\/tr><tr><td>\u2468 \u8054\u52a8\u63a7\u5236\u8c03\u8bd5<\/td><td>\u6e29\u63a7\u5668\u4e0e\u70ed\u6e90\u8054\u52a8\u6b63\u5e38<\/td><td>\u8c03\u8bd5\u8bb0\u5f55<\/td><\/tr><tr><td>\u2469 \u9996\u6b21\u5347\u6e29<\/td><td>\u9010\u65e5\u5347\u6e295\u2103<\/td><td>\u5347\u6e29\u8bb0\u5f55<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udd11&nbsp;<strong>\u5173\u952e\u539f\u5219\uff1a\u6bcf\u4e00\u9053\u5de5\u5e8f\u5b8c\u6210\u540e\u5fc5\u987b\u9a8c\u6536\u5408\u683c\uff0c\u65b9\u53ef\u8fdb\u5165\u4e0b\u4e00\u9053\u3002<\/strong>&nbsp;\u5c24\u5176\u6253\u538b\u2014\u2014\u76d8\u7ba1\u4e00\u65e6\u88ab\u56de\u586b\u8986\u76d6\uff0c\u6cc4\u6f0f\u70b9\u51e0\u4e4e\u65e0\u6cd5\u5b9a\u4f4d\uff0c\u53ea\u80fd\u5168\u90e8\u62c6\u9664\u91cd\u505a\u3002<\/p>\n<\/blockquote>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\">5.5.8\u3001\u5e38\u89c1\u65bd\u5de5\/\u8c03\u8bd5\u95ee\u9898\u901f\u67e5\u8868<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u95ee\u9898<\/th><th>\u6839\u56e0<\/th><th>\u89e3\u51b3\u65b9\u6848<\/th><\/tr><\/thead><tbody><tr><td>\u6709\u7684\u623f\u95f4\u70ed\u3001\u6709\u7684\u623f\u95f4\u51b7<\/td><td>\u6c34\u529b\u5931\u8861\u2014\u2014\u6c34\u5f80\u963b\u529b\u6700\u5c0f\u7684\u5730\u65b9\u6d41<\/td><td>\u6bcf\u652f\u8def\u52a0\u88c5\u5e73\u8861\u9600\/\u6d41\u91cf\u8ba1\uff0c\u8c03\u8282\u81f3\u8bbe\u8ba1\u6d41\u91cf\uff1b\u9a8c\u6536\u6807\u51c6\uff1a\u5404\u623f\u95f4\u6e29\u5dee\u2264\u00b11\u2103<\/td><\/tr><tr><td>\u697c\u4e0a\u70ed\u697c\u4e0b\u51b7\uff08\u591a\u5c42\u5efa\u7b51\uff09<\/td><td>\u5782\u76f4\u6c34\u529b\u5931\u8861<\/td><td>\u6bcf\u5c42\u72ec\u7acb\u5206\u96c6\u6c34\u5668 + \u5c42\u95f4\u5e73\u8861\u9600<\/td><\/tr><tr><td>\u7cfb\u7edf\u9891\u7e41\u542f\u505c<\/td><td>\u9505\u7089\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u8fdc\u8d85\u5c0f\u9762\u79ef\u9700\u6c42\uff1b\u6e29\u63a7\u5668\u4e0e\u9505\u7089\u672a\u8054\u52a8<\/td><td>\u6362\u53d8\u9891\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa3-4kW\uff09+ \u6e29\u63a7\u5668\u8054\u52a8\u9505\u7089\u63a7\u5236<\/td><\/tr><tr><td>\u70ed\u5f97\u6162\uff082-3\u5c0f\u65f6\u624d\u6696\uff09<\/td><td>\u5730\u6696\u5c5e\u50a8\u70ed\u5f0f\u91c7\u6696\uff0c\u9700\u9884\u70ed\u6df7\u51dd\u571f\u56de\u586b\u5c42<\/td><td>\u667a\u80fd\u9884\u70ed\uff1a\u56de\u5bb6\u524d1\u5c0f\u65f6\u8fdc\u7a0b\u5f00\u542f\uff1b\u65e5\u5e38\u6052\u6e29\u8fd0\u884c\u4e0d\u5173\u673a<\/td><\/tr><tr><td>\u7ba1\u9053\u51fa\u9ed1\u6c34\u3001\u6709\u5f02\u5473<\/td><td>\u672a\u4f7f\u7528\u963b\u6c27\u7ba1\u2192\u6c27\u6c14\u6e17\u900f\u8150\u8680<\/td><td>\u6362\u963b\u6c27\u7ba1 + \u7cfb\u7edf\u6e05\u6d17\uff1b\u963b\u6c27\u7ba15\u5e74\u540e\u4f20\u70ed\u6548\u7387\u57fa\u672c\u4e0d\u53d8\uff0c\u666e\u901a\u7ba1\u4e0b\u964d30%+<\/td><\/tr><tr><td>\u53d1\u70ed\u7535\u7f06\u5c40\u90e8\u8fc7\u70ed\/\u4f4e\u6e29<\/td><td>\u94fa\u8bbe\u95f4\u8ddd\u504f\u5dee\uff1e\u00b110mm<\/td><td>\u6309\u8bbe\u8ba1\u95f4\u8ddd\u94fa\u8bbe\uff0c\u504f\u5dee\u63a7\u5236\u5728\u00b110mm\u5185<\/td><\/tr><tr><td>\u56de\u586b\u5c42\u5f00\u88c2<\/td><td>\u9996\u6b21\u5347\u6e29\u8fc7\u5feb \/ \u517b\u62a4\u671f\u5f3a\u5236\u70d8\u5e72 \/ \u53d1\u70ed\u7535\u7f06\u8fc7\u65e9\u901a\u7535<\/td><td>\u9996\u6b21\u4f7f\u7528\u9010\u65e5\u5347\u6e295\u2103\uff0c\u81ea\u7136\u517b\u62a4\u22657\u5929\uff08\u53d1\u70ed\u7535\u7f06\u57ab\u5c42\u226521\u5929\uff09<\/td><\/tr><tr><td>\u5730\u6696\u4e0d\u70ed\u3001\u80fd\u8017\u9ad8<\/td><td>\u6253\u538b\u4e0d\u5408\u683c\u6f0f\u635f \/ \u6c34\u529b\u5931\u8861 \/ \u8054\u52a8\u63a7\u5236\u672a\u8c03\u8bd5<\/td><td>\u4e25\u683c\u6309\u6807\u51c6\u4e09\u6b21\u6253\u538b\uff0c\u505a\u6c34\u529b\u5e73\u8861\u8c03\u8bd5\uff0c\u786e\u8ba4\u8054\u52a8\u63a7\u5236\u6b63\u5e38<\/td><\/tr><tr><td>\u5df2\u88c5\u4fee\u623f\u5b50\u60f3\u52a0\u5730\u6696<\/td><td>\u6c34\u5730\u6696\u9700\u7838\u5730\u9762\uff0c\u4e0d\u73b0\u5b9e<\/td><td>\u5e72\u94fa\u53d1\u70ed\u7535\u7f06\uff08\u4e0d\u7834\u574f\u5730\u9762\uff0c\u76f4\u63a5\u94fa\u5730\u677f\u4e0b\uff09\uff0c1-2\u5929\u5b8c\u5de5\uff0c\u603b\u539a\u5ea6\u589e\u52a03-5mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h2 class=\"wp-block-heading\">\u7b2c\u516d\u7ae0\uff1a\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b<\/h2>\n\n<p class=\"wp-block-paragraph\">\u7406\u8bba\u8bf4\u5f97\u518d\u591a\uff0c\u90fd\u4e0d\u5982\u4e00\u4e2a\u771f\u5b9e\u6848\u4f8b\u6765\u5f97\u6709\u8bf4\u670d\u529b\u3002\u672c\u7ae0\u5c06\u4e3a\u60a8\u5448\u73b0\u77e5\u8bc6\u5e93\u4e2d\u6536\u5f55\u7684\u51e0\u4e2a\u5177\u6709\u4ee3\u8868\u6027\u7684\u5730\u6696\u7cfb\u7edf\u5b9e\u9645\u6848\u4f8b\uff0c\u6309\u7528\u6237\u7c7b\u578b\u5206\u7c7b\uff0c\u5206\u522b\u5c55\u793a\u4e0d\u540c\u75db\u70b9\u4e0b\u7684\u89e3\u51b3\u65b9\u6848\u4e0e\u6700\u7ec8\u6548\u679c\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">6.1 \u6309\u7528\u6237\u7c7b\u578b\u5206\u7c7b\u6848\u4f8b<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6848\u4f8b\u7c7b\u578b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u4ee3\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u539f\u59cb\u95ee\u9898<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u65b9\u6848<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6700\u7ec8\u6548\u679c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u6574\u6848\u4f8b\u6587\u4ef6<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9996\u6b21\u88c5\u4fee\u578b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6768\u54e5\u96c5\u5c45<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6210\u90fd\u623f\u4ea7\u4f7f\u7528\u71c3\u6c14\u58c1\u6302\u7089\u5e26\u5730\u6696\uff0c\u8d39\u7528\u9ad8\uff08\u6708\u5747&gt;1000\u5143\uff09\u3001\u9505\u7089\u5df2\u6362\u4e24\u6b21\u3001\u4f53\u611f\u4e0d\u8212\u670d<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c1f\u5730\u6c34\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u7528\u964d\u81f3400-600\u5143\/\u6708\uff0c\u7cfb\u7edf\u7a33\u5b9a\uff0c\u4f53\u611f\u8212\u9002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u9f99\u8109\u6696\u901a\u00b7\u8212\u9002\u8282\u80fd\u5168\u6848\u65b9\u6848\u4e66\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6362\u623f\u5347\u7ea7\u578b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e07\u8001\u5e08<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u91d1\u6c1f\u7cfb\u7edf\u7a7a\u8c03\uff08\u51b7\u98ce\u76f4\u5439\uff09+ \u5a01\u80fd\u9505\u7089\u5730\u6696\uff0880\u33a1\u5730\u6696\u6708\u8d39\u8d851000\u5143\uff09\uff0c\u70ed\u6c34\u5ffd\u51b7\u5ffd\u70ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b\uff08\u4e3b\u673aRAS-180FPUEN2Q\/M + \u96f6\u8d8a\u98ce\u673a\u76d8\u7ba16\u53f0\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u8c03\u51fa\u98ce\u67d4\u548c\uff0c\u5730\u6696\u5b63\u8d39\u964d\u81f3400-600\u5143\uff0c\u70ed\u6c34\u6052\u6e29\u8212\u9002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u9f99\u8109\u6696\u901a\u7b2c\u516b\u7bc7\uff1a\u771f\u5b9e\u5ba2\u6237\u6848\u4f8b\u300b<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6539\u5584\u578b\u75db\u70b9<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9891\u7e41\u542f\u505c\u5bfc\u81f4\u80fd\u8017\u9ad8\u3001\u5ba4\u6e29\u6ce2\u52a8\u5927\u3001\u7cfb\u7edf\u5bff\u547d\u77ed<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u4f18\u5316\uff1a\u66f4\u6362\u53d8\u9891\u51b7\u51dd\u7089 + \u8054\u52a8\u63a7\u5236 + \u6c34\u529b\u5e73\u8861<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u542f\u505c\u6b21\u6570\u51cf\u5c1170%+\uff0c\u71c3\u6c14\u8d39\u4e0b\u964d30-40%\uff0c\u5ba4\u6e29\u7a33\u5b9a<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u9f99\u8109\u6696\u901a\u7b2c\u4e94\u7bc7\uff1a\u591a\u65b9\u6848\u8bbe\u8ba1\u7406\u5ff5\u300b<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.2 \u6838\u5fc3\u6848\u4f8b\u6df1\u5ea6\u89e3\u6790\uff1a\u4e07\u8001\u5e08\u2014\u2014\u4ece\u5927\u91d1\u6c1f\u7cfb\u7edf+\u5a01\u80fd\u9505\u7089\u5230\u65e5\u7acb\u6c34\u5885\u9002<\/h3>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u662f\u4e00\u4e2a\u975e\u5e38\u7ecf\u5178\u7684\u201c\u4ece\u75db\u82e6\u4e2d\u5347\u7ea7\u201d\u7684\u771f\u5b9e\u6848\u4f8b\uff0c\u4f53\u73b0\u4e86\u4ece\u201c\u4ea7\u54c1\u601d\u7ef4\u201d\u5230\u201c\u7cfb\u7edf\u601d\u7ef4\u201d\u7684\u6839\u672c\u8f6c\u53d8\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>1. \u539f\u6709\u7cfb\u7edf\u4e0e\u75db\u70b9<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5ba2\u6237<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e07\u8001\u5e08<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6237\u578b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u522b\u5885\uff0c\u5e38\u4f4f6\u4eba\uff0c\u6709\u70ed\u6c34\u9700\u6c42<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u539f\u6709\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u91d1\u4e2d\u592e\u7a7a\u8c03\uff08\u6c1f\u7cfb\u7edf\uff09+ \u5a01\u80fd\u666e\u901a\u7089\u5730\u6696<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u539f\u6709\u75db\u70b9<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u8c03\u51b7\u98ce\u76f4\u5439\u3001\u5e72\u71e5\u4e0d\u9002\uff1b\u5730\u6696\u8d39\u7528\u9ad8\uff0880\u33a1\u6708\u8d39\u7528&gt;1000\u5143\uff09\uff1b\u70ed\u6c34\u4f53\u9a8c\u5dee\uff0c\u591a\u70b9\u7528\u6c34\u5ffd\u51b7\u5ffd\u70ed\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>2. \u6839\u56e0\u5206\u6790\uff08\u77e5\u8bc6\u5e93\u89c6\u89d2\uff09<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u4e07\u8001\u5e08\u7684\u65e7\u7cfb\u7edf\u662f\u5178\u578b\u7684\u201c\u8bbe\u5907\u5806\u780c\u201d\uff0c\u800c\u975e\u201c\u7cfb\u7edf\u8bbe\u8ba1\u201d\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u70ed\u6e90<\/strong>\uff1a\u5a01\u80fd\u666e\u901a\u7089\uff0824kW\u6216\u66f4\u5927\uff09\uff0c\u5339\u914d80\u33a1\u5730\u6696\uff0c\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u8fdc\u8d85\u9700\u6c42\uff0c\u5fc5\u7136\u9891\u7e41\u542f\u505c\u3002<\/li>\n\n<li><strong>\u8f93\u914d<\/strong>\uff1a\u5177\u4f53\u914d\u7f6e\u672a\u77e5\uff0c\u4f46\u5f88\u53ef\u80fd\u91c7\u7528\u5f02\u7a0b\u6216\u7ba1\u5f84\u4e0d\u5408\u7406\uff0c\u5bfc\u81f4\u90e8\u5206\u56de\u8def\u6d41\u91cf\u4e0d\u8db3\u3002<\/li>\n\n<li><strong>\u63a7\u5236<\/strong>\uff1a\u9505\u7089\u6309\u6c34\u6e29\u5de5\u4f5c\uff0c\u65e0\u8054\u52a8\u63a7\u5236\uff0c\u5ba4\u6e29\u8fbe\u6807\u540e\u4ecd\u5728\u76f2\u76ee\u70e7\u6c34\uff0c\u65e0\u6548\u4ea7\u70ed\u4e25\u91cd\u3002<\/li>\n\n<li><strong>\u70ed\u6c34<\/strong>\uff1a\u4e24\u7528\u7089\u8bbe\u8ba1\uff0c\u5927\u529f\u7387\u7089\u5b50\u65e2\u8981\u91c7\u6696\u53c8\u8981\u4f9b\u5e94\u5168\u5c4b\u70ed\u6c34\uff0c\u5bfc\u81f4\u91c7\u6696\u5b63\u9891\u7e41\u542f\u505c\uff0c\u70ed\u6c34\u5b63\u6c34\u6e29\u4e0d\u7a33\u5b9a\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>3. \u65b0\u7cfb\u7edf\u914d\u7f6e\u4e0e\u89e3\u51b3\u903b\u8f91<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65b0\u7cfb\u7edf\u7ec4\u4ef6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u62c5\u5f53\u89d2\u8272<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u89e3\u51b3\u903b\u8f91<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u65e5\u7acb\u6c34\u5885\u9002\u5929\u6c34\u5730\u6c34\u4e24\u8054\u4f9b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6e90 + \u51b7\u6e90<\/td><td class=\"has-text-align-left\" data-align=\"left\">1. <strong>\u70ed\u6e90<\/strong>\uff1a\u53d8\u9891\u70ed\u6cf5\uff0c\u53ef\u7cbe\u786e\u5339\u914d\u8d1f\u8377\uff0c\u907f\u514d\u9891\u7e41\u542f\u505c\u3002<br>2. <strong>\u51b7\u6e90<\/strong>\uff1a\u6c34\u7cfb\u7edf\u7a7a\u8c03\uff0c\u51fa\u98ce\u67d4\u548c\uff0c\u4f53\u611f\u8212\u9002\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\uff086\u53f0\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u672b\u7aef\uff08\u7a7a\u8c03\u90e8\u5206\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9ad8\u6548\u3001\u9759\u97f3\u5730\u5b8c\u6210\u5236\u51b7\u4efb\u52a1\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u72ec\u7acb\u70ed\u6c34\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6c34\u4f9b\u5e94<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5f7b\u5e95\u89e3\u51b3\u4e24\u7528\u7089\u7684\u70ed\u6c34\u4e0e\u91c7\u6696\u51b2\u7a81\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8054\u52a8\u63a7\u5236<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63a7\u5236\u4e2d\u67a2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b9e\u73b0\u5ba4\u6e29\u4e0e\u70ed\u6cf5\u8054\u52a8\uff0c\u6309\u9700\u542f\u505c\uff0c\u675c\u7edd\u65e0\u6548\u4ea7\u70ed\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>4. \u9884\u671f\u6536\u76ca\u4e0e\u6838\u5fc3\u4eae\u70b9<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9884\u671f\u6536\u76ca<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7a7a\u8c03\u51fa\u98ce\u67d4\u548c\u4e0d\u5e72\u71e5\uff1b\u5730\u6696\u6708\u8d39\u7528\u4ece&gt;1000\u5143\u964d\u81f3400-600\u5143\uff1b\u72ec\u7acb\u70ed\u6c34\u7cfb\u7edf\uff0c\u6052\u6e29\u8212\u9002\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6838\u5fc3\u4eae\u70b9<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4ece\u75db\u70b9\u51fa\u53d1\u7684\u5b8c\u6574\u5bf9\u6bd4\u6848\u4f8b<\/strong>\uff0c\u5b8c\u7f8e\u4f53\u73b0\u4e86\u6c34\u7cfb\u7edf\uff08\u4e24\u8054\u4f9b\uff09\u5728\u8212\u9002\u5ea6\u548c\u957f\u671f\u8282\u80fd\u4e0a\u76f8\u5bf9\u4e8e\u4f20\u7edf\u71c3\u6c14\u9505\u7089+\u6c1f\u7cfb\u7edf\u7a7a\u8c03\u7684\u5168\u9762\u4f18\u52bf\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">6.3 \u6848\u4f8b\u542f\u793a<\/h3>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u4e9b\u771f\u5b9e\u6848\u4f8b\u544a\u8bc9\u6211\u4eec\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u5730\u6696\u662f\u201c\u7cfb\u7edf\u201d\u800c\u975e\u201c\u4ea7\u54c1\u201d<\/strong>\u3002\u4e07\u8001\u5e08\u5bb6\u539f\u6765\u7684\u5927\u91d1+\u5a01\u80fd\u7ec4\u5408\uff0c\u90fd\u662f\u77e5\u540d\u54c1\u724c\uff0c\u4f46\u7cfb\u7edf\u5339\u914d\u4e0d\u4f73\uff0c\u6548\u679c\u4f9d\u7136\u5f88\u5dee\u3002<\/li>\n\n<li><strong>\u957f\u671f\u8282\u80fd\u624d\u662f\u771f\u6b63\u7684\u7701\u94b1<\/strong>\u3002\u867d\u7136\u6c34\u5885\u9002\u4e24\u8054\u4f9b\u7684\u521d\u6295\u8d44\u53ef\u80fd\u8f83\u9ad8\uff0c\u4f46\u5176\u6781\u4f4e\u7684\u8fd0\u884c\u8d39\u7528\u572820\u5e74\u7ef4\u5ea6\u4e0b\u662f\u7edd\u5bf9\u6700\u7701\u7684\u3002<\/li>\n\n<li><strong>\u4e13\u4e1a\u7684\u8bbe\u8ba1\u662f\u6210\u529f\u7684\u7075\u9b42<\/strong>\u3002\u6ca1\u6709\u4e13\u4e1a\u7684\u8d1f\u8377\u8ba1\u7b97\u3001\u6c34\u529b\u5e73\u8861\u548c\u8054\u52a8\u63a7\u5236\u8bbe\u8ba1\uff0c\u518d\u597d\u7684\u8bbe\u5907\u4e5f\u65e0\u6cd5\u53d1\u6325\u5176\u5e94\u6709\u7684\u6027\u80fd\u3002<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\"><strong>\u8865\u5145\u6848\u4f8b\u4e00\uff1a\u6210\u90fd \u00b7 \u8f9b\u603b 450\u33a1 \u522b\u5885 \u00b7 \u7a7a\u6c14\u80fd\u5730\u6696\u5168\u5c4b\u91c7\u6696<\/strong>\u2192<a href=\"https:\/\/longmai-nt.com\/?page_id=448\">\u6210\u90fd\u548c\u8d35\u5357\u5c71\u4e0a\u00b7\u8f9b\u603b\u522b\u5885\uff1a\u4ece\u201c\u793c\u8c8c\u6027\u62dc\u8bbf\u201d\u5230\u201c\u4e3b\u52a8\u6652\u5355\u201d - \u9f99\u8109\u6696\u901a<\/a><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\">\u65b9\u6848\u6838\u5fc3\u4ef7\u503c\uff1a\u7cfb\u7edf\u4f18\u5316\u6bd4\u6362\u8bbe\u5907\u66f4\u91cd\u8981\u3002\u51b7\u51dd\u7089+\u6c34\u529b\u5e73\u8861+\u8054\u52a8\u63a7\u5236+\u6c14\u5019\u8865\u507f\u7684\u7ec4\u5408\uff0c\u6548\u679c\u8fdc\u8d85\u5355\u72ec\u6362\u4e00\u53f0\u51b7\u51dd\u7089\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u72b6\u6001\uff1a\u5df2\u5b8c\u5de5\uff0c\u6570\u636e\u7ecf3\u4e2a\u91c7\u6696\u5b63\u9a8c\u8bc1<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>\u8865\u5145\u6848\u4f8b\u4e09\uff1a\u6210\u90fd \u00b7 \u674e\u6d77 220\u33a1 \u590d\u5f0f \u00b7 \u7cfb\u7edf\u7089+\u72ec\u7acb\u70ed\u6c34\u65b9\u6848<\/strong>\u2192<a href=\"https:\/\/longmai-nt.com\/?page_id=10066\">\u5929\u5e9c\u65b0\u533a\u7fe1\u7fe0\u548c\u60a6 173\u33a1\u5730\u6696\u5b9e\u6d4b\uff5c\u51b7\u51dd\u7089\u5730\u6696\u6708\u5747350 \u5143 - \u9f99\u8109\u6696\u901a<\/a><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ef4\u5ea6<\/th><th>\u8be6\u60c5<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u6237\u753b\u50cf<\/td><td>220\u33a1\u590d\u5f0f\uff0c\u56db\u53e3\u4e4b\u5bb6\uff08\u592b\u5987+2\u4e2a\u9752\u5c11\u5e74\uff09<\/td><\/tr><tr><td>\u539f\u65b9\u6848<\/td><td>\u4e24\u7528\u58c1\u6302\u7089 + \u6c34\u5730\u6696 + \u751f\u6d3b\u70ed\u6c34<\/td><\/tr><tr><td>\u75db\u70b9<\/td><td>\u6d17\u6fa1\u65f6\u5730\u6696\u6c34\u6e29\u6ce2\u52a8\uff1b\u590f\u5b63\u70ed\u6c34\u6c34\u6e29\u8fc7\u70eb\uff0c\u5ffd\u51b7\u5ffd\u70ed\uff1b\u51ac\u5b63\u540c\u65f6\u6d17\u6fa1+\u91c7\u6696\u65f6\u4e24\u7528\u7089\u8d85\u8d1f\u8377\u62a5\u8b66<\/td><\/tr><tr><td>\u89e3\u51b3\u65b9\u6848<\/td><td>\u91c7\u6696\u4e0e\u70ed\u6c34\u5b8c\u5168\u5206\u79bb\uff1a\u7cfb\u7edf\u7089\uff08\u5355\u91c7\u6696\uff09+ \u6052\u6e29\u71c3\u6c14\u70ed\u6c34\u5668 + \u4e3b\u7ba1\u5faa\u73af\u70ed\u6c34\u7ba1\u8def<\/td><\/tr><tr><td>\u6539\u9020\u6548\u679c<\/td><td>\u2460\u91c7\u6696\u4e0e\u70ed\u6c34\u5404\u81ea\u72ec\u7acb\u8fd0\u884c\uff0c\u4e92\u4e0d\u5e72\u6270\uff1b\u2461\u70ed\u6c34\u7a33\u5b9a\u4f9b\u5e94\uff0c\u4e0d\u518d\u5ffd\u51b7\u5ffd\u70ed\uff1b\u2462\u4e3b\u7ba1\u5faa\u73af\u66ff\u4ee3\u96f6\u51b7\u6c34\uff0c\u70ed\u6c34\u5373\u6765\u5373\u70ed\uff0c\u65e0\u6301\u7eed\u70ed\u635f\u8017<\/td><\/tr><tr><td>\u5ba2\u6237\u53cd\u9988<\/td><td>\"\u4ee5\u524d\u6d17\u6fa1\u50cf\u5f00\u76f2\u76d2\u2014\u2014\u662f\u70eb\u8fd8\u662f\u51b7\u5168\u770b\u8fd0\u6c14\u3002\u73b0\u5728\u70ed\u6c34\u4e00\u5f00\u5c31\u6709\uff0c\u6e29\u5ea6\u7a33\u7a33\u7684\uff0c\u518d\u4e5f\u4e0d\u62c5\u5fc3\u5b69\u5b50\u6d17\u6fa1\u5ffd\u51b7\u5ffd\u70ed\u4e86\u3002\"<\/td><\/tr><tr><td>\u65b9\u6848\u6838\u5fc3\u4ef7\u503c<\/td><td>\u91c7\u6696\u4e0e\u70ed\u6c34\u5206\u79bb\u662f\u9f99\u8109\u6838\u5fc3\u8bbe\u8ba1\u539f\u5219\u3002\u4e24\u7528\u7089\u7684\u8bbe\u8ba1\u77db\u76fe\u65e0\u6cd5\u901a\u8fc7\u53c2\u6570\u4f18\u5316\u89e3\u51b3\uff0c\u53ea\u80fd\u901a\u8fc7\u7cfb\u7edf\u67b6\u6784\u5206\u79bb\u6765\u89e3\u51b3\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>\u8865\u5145\u6848\u4f8b\u56db\uff1a\u6210\u90fd \u00b7 \u6881\u603b 350\u33a1 \u529e\u516c+\u4f4f\u5b85 \u00b7 \u6df7\u5408\u70ed\u6e90\u65b9\u6848<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ef4\u5ea6<\/th><th>\u8be6\u60c5<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u6237\u753b\u50cf<\/td><td>350\u33a1\u4e09\u5c42\u5efa\u7b51\uff0c1-2\u5c42\u4e3a\u8bbe\u8ba1\u516c\u53f8\u529e\u516c\u5ba4\uff0c3\u5c42\u4e3a\u79c1\u4eba\u4f4f\u5b85<\/td><\/tr><tr><td>\u539f\u65b9\u6848<\/td><td>32kW\u71c3\u6c14\u58c1\u6302\u7089 + \u6696\u6c14\u7247\uff08\u529e\u516c\u533a\uff09+ \u5730\u6696\uff08\u4f4f\u5b85\u533a\uff09\u6df7\u88c5<\/td><\/tr><tr><td>\u75db\u70b9<\/td><td>\u529e\u516c\u533a\u4ec5\u767d\u5929\u4f7f\u7528\uff0c\u4f4f\u5b85\u533a\u5168\u5929\u4f7f\u7528\uff0c\u4f46\u4e00\u5957\u9505\u7089\u65e0\u6cd5\u5206\u533a\u63a7\u5236\uff1b\u6696\u6c14\u7247\u533a\u57df\u70ed\u3001\u5730\u6696\u533a\u57df\u6e29\uff08\u6df7\u88c5\u7cfb\u7edf\u6c34\u529b\u5931\u8861\uff09\uff1b\u6708\u71c3\u6c14\u8d394500-6000\u5143<\/td><\/tr><tr><td>\u89e3\u51b3\u65b9\u6848<\/td><td>\u529e\u516c\u533a\u6539\u4e3a\u72ec\u7acb\u7684\u51b7\u51dd\u7089+\u4f4e\u6e29\u6696\u6c14\u7247\u7cfb\u7edf\uff08\u5de5\u4f5c\u65f6\u95f4\u6bb5\u5b9a\u65f6\u8fd0\u884c\uff09\uff1b\u4f4f\u5b85\u533a\u72ec\u7acb\u7a7a\u6c14\u80fd\u5730\u6696\u7cfb\u7edf\uff1b\u751f\u6d3b\u70ed\u6c34\u7531\u7cfb\u7edf\u7089+\u70ed\u6c34\u7bb1\u72ec\u7acb\u4f9b\u5e94<\/td><\/tr><tr><td>\u6539\u9020\u6548\u679c<\/td><td>\u2460\u529e\u516c\u533a\u6708\u71c3\u6c14\u8d39\u964d\u81f3\u7ea6800\u5143\uff08\u4ec5\u5de5\u4f5c\u65e5\u767d\u5929\u8fd0\u884c\uff09\uff1b\u2461\u4f4f\u5b85\u533a\u6708\u7535\u8d39\u7ea61200\u5143\uff1b\u2462\u603b\u8ba1\u8fd0\u884c\u8d39\u7ea62000\u5143\/\u6708\uff0c\u6bd4\u539f\u65b9\u6848\u770155%+\uff1b\u2463\u529e\u516c\u533a\u548c\u4f4f\u5b85\u533a\u5404\u81ea\u72ec\u7acb\u63a7\u5236\uff0c\u4e92\u4e0d\u5f71\u54cd<\/td><\/tr><tr><td>\u5ba2\u6237\u53cd\u9988<\/td><td>\"\u4ee5\u524d\u516c\u53f8\u91c7\u6696\u8ddf\u7740\u5bb6\u91cc\u8d70\uff0c\u5468\u672b\u4e0d\u4e0a\u73ed\u9505\u7089\u7167\u6837\u70e7\u3002\u73b0\u5728\u5404\u7ba1\u5404\u7684\uff0c\u8d39\u7528\u964d\u4e86\u4e00\u5927\u622a\uff0c\u5458\u5de5\u8bf4\u529e\u516c\u5ba4\u6bd4\u4e4b\u524d\u6696\u548c\u591a\u4e86\u3002\"<\/td><\/tr><tr><td>\u65b9\u6848\u6838\u5fc3\u4ef7\u503c<\/td><td>\u4e0d\u540c\u4f7f\u7528\u573a\u666f\u5206\u533a\u72ec\u7acb\u63a7\u5236\uff0c\u662f\u5927\u578b\u6df7\u5408\u7528\u9014\u5efa\u7b51\u7684\u6700\u4f18\u89e3\u3002\u4e09\u5957\u7cfb\u7edf\u5404\u53f8\u5176\u804c\uff0c\u65e2\u8282\u80fd\u53c8\u7075\u6d3b\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 id=\"dnxt07\" class=\"wp-block-heading\">\u7b2c\u4e03\u7ae0\uff1a\u672a\u6765\u5c55\u671b\u4e0e\u667a\u80fd\u5347\u7ea7<\/h2>\n\n<p class=\"wp-block-paragraph\">\u5730\u6696\u7cfb\u7edf\u4e0d\u518d\u53ea\u662f\u4e00\u4e2a\u201c\u51ac\u5929\u53d6\u6696\u201d\u7684\u8bbe\u5907\uff0c\u5b83\u6b63\u5728\u6f14\u8fdb\u4e3a\u667a\u80fd\u5bb6\u5c45\u7cfb\u7edf\u4e2d\u7684\u6838\u5fc3\u4e00\u73af\u3002\u672c\u7ae0\u5c06\u4e3a\u60a8\u68b3\u7406\u5730\u6696\u7cfb\u7edf\u672a\u6765\u7684\u53d1\u5c55\u8d8b\u52bf\uff0c\u4ee5\u53ca\u5728\u300a\u4e2d\u56fd\u4e94\u6052\u884c\u4e1a\u53d1\u5c55\u767d\u76ae\u4e66\u300b\u4e2d\u6240\u63cf\u7ed8\u7684\u524d\u6cbf\u6280\u672f\u6784\u60f3\u3002<\/p>\n\n<h3 id=\"dnxt0701\" class=\"wp-block-heading\">7.1 \u5730\u6696\u7cfb\u7edf\u7684\u53d1\u5c55\u8d8b\u52bf<\/h3>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u300a\u4e2d\u56fd\u4e94\u6052\u884c\u4e1a\u53d1\u5c55\u767d\u76ae\u4e661.0\u7248\u300b\u548c\u300a\u9f99\u8109\u6696\u901a\u4eba\u673a\u534f\u4f5c\u667a\u80fd\u4f53\u5b8c\u6574\u84dd\u56fe\u300b\uff0c\u672a\u67653-5\u5e74\uff0c\u5730\u6696\u7cfb\u7edf\u7684\u53d1\u5c55\u5c06\u56f4\u7ed5\u201c\u4f4e\u78b3\u5316\u3001\u667a\u80fd\u5316\u3001\u5065\u5eb7\u5316\u3001\u96c6\u6210\u5316\u201d\u56db\u5927\u65b9\u5411\u6f14\u8fdb\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u8d8b\u52bf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6280\u672f\u9a71\u52a8<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u7528\u6237\u7684\u5f71\u54cd<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f4e\u78b3\u5316<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5149\u4f0f\/\u50a8\u80fd\u9a71\u52a8\u3001\u591a\u80fd\u4e92\u8865\u5e94\u7528\u3001\u73af\u4fdd\u5236\u51b7\u5242\u66ff\u4ee3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ed\u6cf5\u6280\u672f\u6210\u719f\u3001\u5149\u4f0f\u6210\u672c\u4e0b\u964d\u3001\u201c\u53cc\u78b3\u201d\u653f\u7b56\u63a8\u52a8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd0\u884c\u8d39\u7528\u66f4\u4f4e\uff0c\u751a\u81f3\u53ef\u80fd\u5b9e\u73b0\u201c\u96f6\u78b3\u6392\u653e\u91c7\u6696\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u667a\u80fd\u5316<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">AI\u81ea\u5b66\u4e60\u3001IoT\u4e92\u8054\u3001\u975e\u63a5\u89e6\u5f0f\u4f20\u611f\u5668\u3001\u6570\u5b57\u5316\u8bc4\u4ef7\u4f53\u7cfb<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>AI\u6280\u672f<\/strong>\uff08\u5982DS\uff09\u3001<strong>IoT\u4f20\u611f\u5668<\/strong>\u3001<strong>\u8fb9\u7f18\u8ba1\u7b97<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u201c\u4e3b\u52a8\u670d\u52a1\u201d\uff1a\u81ea\u52a8\u9002\u5e94\u7528\u6237\u4e60\u60ef\uff0c\u65e0\u9700\u4eba\u5de5\u5e72\u9884<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5065\u5eb7\u5316<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u533b\u7597\u7ea7\u51c0\u5316\u3001\u8d1f\u6c27\u79bb\u5b50\u8c03\u8282\u3001\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65b0\u98ce\u7cfb\u7edf\u5347\u7ea7\u3001\u7a7a\u6c14\u51c0\u5316\u6280\u672f\u3001\u6e7f\u5ea6\u63a7\u5236\u6280\u672f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ece\u201c\u8212\u9002\u201d\u5347\u7ea7\u5230\u201c\u5065\u5eb7\u201d\uff0c\u771f\u6b63\u5b9e\u73b0\u201c\u5eb7\u5c45\u201d<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u96c6\u6210\u5316<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6a21\u5757\u5316\u8bbe\u8ba1\u3001\u591a\u80fd\u6e90\u8026\u5408\u3001\u533a\u57df\u534f\u540c<\/td><td class=\"has-text-align-left\" data-align=\"left\">BIM\u5efa\u6a21\u3001\u52a8\u6001\u8d1f\u8377\u8ba1\u7b97\u8f6f\u4ef6\u3001\u667a\u80fd\u63a7\u5236\u5e73\u53f0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u66f4\u7b80\u6d01\u3001\u5b89\u88c5\u66f4\u4fbf\u6377\u3001\u7ef4\u62a4\u66f4\u7701\u5fc3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\"><strong>\u660e\u661f\u6280\u672fTOP5<\/strong><\/h4>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6392\u540d<\/th><th>\u6280\u672f\u540d\u79f0<\/th><th>\u6280\u672f\u539f\u7406<\/th><th>\u843d\u5730\u8fdb\u5c55<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>\u5149\u50a8\u70ed\u4e00\u4f53\u5316<\/td><td>\u5149\u4f0f\u53d1\u7535 + \u50a8\u80fd\u7535\u6c60 + \u70ed\u6cf5\u91c7\u6696\u4e09\u5408\u4e00<\/td><td>\u9752\u5c9b\u5df2\u6709\u96f6\u78b3\u793e\u533a\u8bd5\u70b9\uff0c\u6210\u672c\u56de\u6536\u5468\u671f5\u5e74<\/td><\/tr><tr><td>2<\/td><td>AI\u70ed\u80fd\u7ba1\u5bb6<\/td><td>\u5b66\u4e60\u7528\u6237\u4f5c\u606f\u4e60\u60ef\uff0c\u81ea\u52a8\u9884\u70ed\u6c34\u6e29\u3001\u5207\u6362\u70ed\u6e90\u3001\u4f18\u5316\u8fd0\u884c\u7b56\u7565<\/td><td>\u534e\u4e3a\u5b9e\u9a8c\u5ba4\u6570\u636e\uff1a\u8282\u753519%<\/td><\/tr><tr><td>3<\/td><td>\u76f8\u53d8\u50a8\u70ed\u6750\u6599<\/td><td>35\u2103\u65f6\u81ea\u52a8\u5438\u70ed\/\u653e\u70ed\uff0c\u7528\u4e8e\u8de8\u65f6\u6bb5\u70ed\u80fd\u50a8\u5b58<\/td><td>\u5df2\u5f00\u59cb\u5e94\u7528\u4e8e\u9ad8\u7aef\u4f4f\u5b85\u7a97\u819c<\/td><\/tr><tr><td>4<\/td><td>\u8de8\u5b63\u8282\u84c4\u80fd<\/td><td>\u5229\u7528\u5730\u6e90\u70ed\u6cf5\uff0c\u590f\u5b63\u50a8\u70ed\u4e8e\u5730\u4e0b\uff0c\u51ac\u5b63\u53d6\u7528<\/td><td>\u5317\u4eac\u8bd5\u70b9\u7701\u7164\u738746%<\/td><\/tr><tr><td>5<\/td><td>\u6c22\u80fd\u91c7\u6696<\/td><td>\u7eaf\u6c22\u71c3\u70e7\uff0c\u96f6\u78b3\u6392\u653e\uff0c\u70ed\u6548\u738798%<\/td><td>\u4e07\u548c\u5df2\u542f\u52a8\u8bd5\u70b9\u7814\u53d1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading\"><strong>\u672a\u6765\u5bb6\u5ead\u91c7\u6696\u573a\u666f\u5bf9\u6bd4<\/strong><\/h4>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7ef4\u5ea6<\/th><th>\u5f53\u524d\u73b0\u72b6<\/th><th>\u672a\u6765\u573a\u666f<\/th><\/tr><\/thead><tbody><tr><td>\u91c7\u6696<\/td><td>\u624b\u52a8\u5f00\u5173\uff0c\u7b492-3\u5c0f\u65f6\u5347\u6e29<\/td><td>AI\u9884\u5224\u56de\u5bb6\u65f6\u95f4\uff0c\u63d0\u524d\u9884\u70ed\uff0c\u5230\u5bb6\u5373\u6696<\/td><\/tr><tr><td>\u591a\u623f\u95f4<\/td><td>\u6709\u7684\u623f\u95f4\u70ed\u3001\u6709\u7684\u51b7<\/td><td>\u5206\u5ba4\u72ec\u7acbAI\u63a7\u6e29\uff0c\u6309\u4eba\u5458\u6d3b\u52a8\u81ea\u52a8\u8c03\u8282<\/td><\/tr><tr><td>\u80fd\u8017<\/td><td>\u6bcf\u6708\u71c3\u6c14\/\u7535\u8d39\u7a33\u5b9a\u652f\u51fa<\/td><td>\u5149\u4f0f+\u50a8\u80fd+\u70ed\u6cf5\uff0c\u91c7\u6696\u8fd1\u4e4e\"\u514d\u8d39\"<\/td><\/tr><tr><td>\u63a7\u5236<\/td><td>\u9762\u677f\u6309\u94ae\u6216APP<\/td><td>\u5168\u5c4b\u8054\u52a8\uff1a\u8bed\u97f3\"\u6211\u51b7\u4e86\"\u81ea\u52a8\u8c03\u6e29+\u5173\u95ed\u8be5\u533a\u57df\u7a97\u6237<\/td><\/tr><tr><td>\u7ef4\u62a4<\/td><td>\u574f\u4e86\u624d\u627e\u4eba\u4fee<\/td><td>\u7cfb\u7edf\u81ea\u8bca\u65ad\uff0c\u6545\u969c\u9884\u8b66\u63d0\u524d\u63a8\u9001\uff0c\u4e3b\u52a8\u4e0a\u95e8\u670d\u52a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 id=\"dnxt0702\" class=\"wp-block-heading\">7.2 \u524d\u6cbf\u6280\u672f\uff1a\u4ece\u201c\u4e94\u6052\u201d\u5230\u201c\u516b\u9002\u201d<\/h3>\n\n<p class=\"wp-block-paragraph\">\u300a\u4e2d\u56fd\u4e94\u6052\u884c\u4e1a\u53d1\u5c55\u767d\u76ae\u4e661.0\u7248\u300b\u63d0\u51fa\u4e86\u4e00\u4e2a\u5168\u65b0\u7684\u6982\u5ff5\uff1a<strong>\u4ece\u201c\u4e94\u6052\u201d\u5230\u201c\u516b\u9002\u201d<\/strong>\u3002<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4f20\u7edf\u201c\u4e94\u6052\u201d<\/strong>\uff1a\u4ec5\u9488\u5bf9\u4f20\u7edf\u4eba\u5c45\u73af\u5883\u7684\u56db\u5927\u7ef4\u5ea6\u2014\u2014<strong>\u70ed\u3001\u6e7f\u3001\u7a7a\u6c14\u3001\u58f0<\/strong>\u3002<\/li>\n\n<li><strong>\u672a\u6765\u7684\u201c\u516b\u9002\u201d<\/strong>\uff1a\u5728\u201c\u4e94\u6052\u201d\u57fa\u7840\u4e0a\uff0c\u589e\u52a0\u4e86<strong>\u5149\u73af\u5883\u3001\u751f\u6d3b\u7528\u6c34\u7cfb\u7edf\u3001\u8282\u80fd\u548c\u667a\u80fd<\/strong>\u7684\u9700\u6c42\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">\u8fd9\u610f\u5473\u7740\uff0c\u672a\u6765\u7684\u5730\u6696\u7cfb\u7edf\u4e0d\u4ec5\u4ec5\u662f\u4f9b\u6696\u8bbe\u5907\uff0c\u800c\u662f\u4e00\u4e2a\u96c6\u6210\u4e86<strong>\u6052\u6e29\u3001\u6052\u6e7f\u3001\u6052\u6c27\u3001\u6052\u9759\u3001\u6052\u6d01\u3001\u5149\u73af\u5883\u3001\u6c34\u7cfb\u7edf\u548c\u667a\u80fd\u63a7\u5236<\/strong>\u4e8e\u4e00\u4f53\u7684\u7efc\u5408\u6027\u201c\u5ba4\u5185\u73af\u5883\u7ba1\u7406\u7cfb\u7edf\u201d\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f20\u7edf\u201c\u4e94\u6052\u201d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u672a\u6765\u201c\u516b\u9002\u201d<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u5730\u6696\u7cfb\u7edf\u7684\u8981\u6c42<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u73af\u5883<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u6e29<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u6e29<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cbe\u51c6\u63a7\u6e29\uff0c\u591a\u80fd\u4e92\u8865<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6e7f\u73af\u5883<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u6e7f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u6e7f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\uff0c\u667a\u80fd\u9664\u6e7f\/\u52a0\u6e7f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7a7a\u6c14\u73af\u5883<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u6c27\uff08\u7a7a\u6c14\u6d01\u51c0\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u6c27 + \u533b\u7597\u7ea7\u51c0\u5316<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u66f4\u9ad8\u6548\u7684\u65b0\u98ce\u4e0e\u51c0\u5316\u7cfb\u7edf<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u58f0\u73af\u5883<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u9759<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u6052\u9759<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8d85\u9759\u97f3\u8fd0\u884c\uff0c\u9694\u97f3\u6750\u6599\u5e94\u7528<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5149\u73af\u5883<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u672a\u7eb3\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u667a\u80fd\u8c03\u5149<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0e\u7a97\u5e18\u3001\u7167\u660e\u7cfb\u7edf\u8054\u52a8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7528\u6c34\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u672a\u7eb3\u5165<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u5065\u5eb7\u7528\u6c34<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u5c4b\u70ed\u6c34\u5faa\u73af\uff0c\u8f6f\u6c34\u5904\u7406<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8282\u80fd<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u672a\u4f53\u73b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u9ad8\u6548\u8282\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">AI\u80fd\u8017\u7ba1\u7406\uff0c\u5149\u4f0f\u50a8\u80fd<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u667a\u80fd<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u274c \u672a\u4f53\u73b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2705 \u667a\u63a7\u4e92\u8054<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u5c4b\u667a\u80fd\u8054\u52a8\uff0c\u81ea\u4e3b\u5b66\u4e60<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 id=\"dnxt0703\" class=\"wp-block-heading\">7.3 \u667a\u80fd\u5bb6\u5c45\u4e0e\u5730\u6696\u7cfb\u7edf\u7684\u6df1\u5ea6\u878d\u5408<\/h3>\n\n<p class=\"wp-block-paragraph\">\u667a\u80fd\u63a7\u5236\u7cfb\u7edf\u662f\u8fde\u63a5\u5730\u6696\u7cfb\u7edf\u4e0e\u672a\u6765\u201c\u516b\u9002\u201d\u76ee\u6807\u7684\u6865\u6881\u3002\u6839\u636e\u8d44\u6599\uff0c\u667a\u80fd\u63a7\u5236\u7684\u6f14\u8fdb\u65b9\u5411\u662f\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u4ece\u201c\u88ab\u52a8\u54cd\u5e94\u201d\u5230\u201c\u4e3b\u52a8\u670d\u52a1\u201d<\/strong>\uff1a\n<ul class=\"wp-block-list\">\n<li><strong>\u73b0\u5728<\/strong>\uff1a\u7528\u6237\u8bbe\u7f6e\u6e29\u5ea6 \u2192 \u7cfb\u7edf\u6267\u884c\u3002<\/li>\n\n<li><strong>\u672a\u6765<\/strong>\uff1a\u7cfb\u7edf\u901a\u8fc7AI\u7b97\u6cd5\u5b66\u4e60\u7528\u6237\u4e60\u60ef\u3001\u9884\u5224\u5929\u6c14\u53d8\u5316\uff0c<strong>\u4e3b\u52a8<\/strong>\u8c03\u8282\u5ba4\u5185\u7a7a\u6c14\u53c2\u6570\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u6838\u5fc3\u8bbe\u5907\uff1aAI\u667a\u6167\u96c6\u63a7\u5c4f\uff08\u5982\u65e5\u7acb11\u5bf8AI\u667a\u6167\u96c6\u63a7\u5c4f\uff09<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>\u4e00\u5c4f\u638c\u63a7<\/strong>\uff1a\u4ee53D\u53ef\u89c6\u5316\u6237\u578b\u56fe\u5f62\u5f0f\uff0c\u76f4\u89c2\u5c55\u793a\u5168\u5c4b\u6bcf\u4e2a\u623f\u95f4\u7684\u6e29\u5ea6\u3001\u6e7f\u5ea6\u3001PM2.5\u3001CO\u2082\u7b49\u7a7a\u6c14\u72b6\u6001\u3002<\/li>\n\n<li><strong>AI\u8bed\u97f3\u4ea4\u4e92<\/strong>\uff1a\u652f\u6301\u6a21\u7cca\u6307\u4ee4\uff08\u5982\u201c\u5c0f\u7acb\u5c0f\u7acb\uff0c\u5c4b\u91cc\u6709\u70b9\u70ed\u201d\uff09\uff0c\u8001\u4eba\u5c0f\u5b69\u4e5f\u80fd\u8f7b\u677e\u63a7\u5236\u3002<\/li>\n\n<li><strong>\u4e3b\u52a8\u7ba1\u5bb6<\/strong>\uff1a24\u5c0f\u65f6\u5728\u7ebf\u7684AI\u7a7a\u6c14\u7ba1\u5bb6\uff0c\u81ea\u52a8\u8054\u52a8\u7a7a\u8c03\u3001\u65b0\u98ce\u3001\u5730\u6696\u3001\u706f\u5149\u3001\u7a97\u5e18\u7b49\u8bbe\u5907\u3002<\/li>\n<\/ul>\n<\/li>\n\n<li><strong>\u6280\u672f\u67b6\u6784\uff1a\u8fb9\u7f18\u8ba1\u7b97 + \u4e91\u8ba1\u7b97\u534f\u540c<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>\u8fb9\u7f18\u8ba1\u7b97<\/strong>\uff1a\u672c\u5730\u5316\u5904\u7406\u6e29\u6e7f\u5ea6\u3001CO\u2082\u7b49\u4f20\u611f\u5668\u6570\u636e\uff0c\u5373\u4f7f\u65ad\u7f51\u4e5f\u80fd\u4fdd\u8bc1\u7cfb\u7edf\u7a33\u5b9a\u8fd0\u884c\u3002<\/li>\n\n<li><strong>\u4e91\u8ba1\u7b97<\/strong>\uff1a\u5229\u7528\u4e91\u7aef\u5927\u6570\u636e\u5206\u6790\uff0c\u4f18\u5316\u957f\u671f\u7684\u80fd\u6548\u7b56\u7565\uff0c\u63d0\u5347\u7528\u6237\u8212\u9002\u5ea6\u548c\u6ee1\u610f\u7387\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n<h3 id=\"dnxt0704\" class=\"wp-block-heading\">7.4 \u672a\u6765\u6280\u672f\u8d8b\u52bf\uff1aAIoT\u4e0e\u6570\u5b57\u5b6a\u751f<\/h3>\n\n<p class=\"wp-block-paragraph\">\u300a\u4e2d\u56fd\u4e94\u6052\u884c\u4e1a\u53d1\u5c55\u767d\u76ae\u4e661.0\u7248\u300b\u8fd8\u5c55\u671b\u4e86\u66f4\u524d\u6cbf\u7684\u6280\u672f\u5e94\u7528\uff1a<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u6570\u5b57\u5b6a\u751f\u4e0e\u9884\u6d4b\u63a7\u5236<\/strong>\uff1a\u57fa\u4e8e\u5efa\u7b51\u7684BIM\u6a21\u578b\u548c\u5b9e\u65f6\u4f20\u611f\u5668\u6570\u636e\uff0c\u6784\u5efa\u865a\u62df\u7684\u201c\u6570\u5b57\u5b6a\u751f\u201d\u7cfb\u7edf\u3002AI\u53ef\u4ee5\u5728\u865a\u62df\u73af\u5883\u4e2d\u6a21\u62df\u4e0d\u540c\u8fd0\u884c\u7b56\u7565\uff0c\u627e\u5230\u6700\u4f73\u65b9\u6848\u540e\uff0c\u518d\u5e94\u7528\u5230\u771f\u5b9e\u7cfb\u7edf\uff0c\u5b9e\u73b0\u201c\u9884\u77e5\u672a\u6765\u201d\u5f0f\u7684\u667a\u80fd\u63a7\u5236\u3002<\/li>\n\n<li><strong>AI\u81ea\u9002\u5e94\u6a21\u578b<\/strong>\uff1a\u57fa\u4e8e\u7528\u6237\u5065\u5eb7\u6570\u636e\uff08\u5982\u6e29\u5ea6\u8bbe\u5b9a\u4e60\u60ef\u3001\u65e5\u5e38\u7a7f\u8863\u4e60\u60ef\u3001\u7761\u7720\u65f6\u95f4\uff09\uff0cAI\u5c06\u5b66\u4e60\u5e76\u5efa\u7acb\u201c\u7528\u6237\u4e2a\u6027\u5316\u884c\u4e3a\u6863\u6848\u201d\u3002\u7cfb\u7edf\u4e0d\u518d\u662f\u6267\u884c\u56fa\u5b9a\u53c2\u6570\uff0c\u800c\u662f\u80fd<strong>\u52a8\u6001\u8c03\u6574\u73af\u5883\u53c2\u6570<\/strong>\uff0c\u5b9e\u73b0\u771f\u6b63\u7684\u201c\u56e0\u4eba\u800c\u5f02\u201d\u7684\u5ba4\u5185\u73af\u5883\u8c03\u8282\u3002<\/li>\n\n<li><strong>\u533a\u5757\u94fe\u6570\u636e\u7ba1\u7406<\/strong>\uff1a\u672a\u6765\uff0c\u201c\u4e94\u6052\u201d\u63a7\u5236\u5668\u7684\u901a\u8baf\u6a21\u7ec4\u5c06\u5347\u7ea7\u4e3a\u5e26\u533a\u5757\u94fe\u6280\u672f\u7684\u6a21\u7ec4\u3002\u8fd9\u53ef\u4ee5\u786e\u4fdd\u8fd0\u884c\u6570\u636e\u4e0a\u94fe\u540e\u7684<strong>\u4e0d\u53ef\u7be1\u6539\u548c\u53ef\u4fe1\u6027<\/strong>\uff0c\u4e3a\u672a\u6765\u7684\u78b3\u4ea4\u6613\u3001\u6570\u636e\u8d44\u4ea7\u589e\u503c\u53d8\u73b0\u63d0\u4f9b\u6280\u672f\u57fa\u7840\uff0c\u540c\u65f6\u4fdd\u969c\u7528\u6237\u9690\u79c1\u3002<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\"><strong>\u6b63\u5728\u53d1\u751f\u7684\u884c\u4e1a\u53d8\u9769<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u53d8\u9769\u65b9\u5411<\/th><th>\u5177\u4f53\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u80fd\u6548\u6807\u51c6\u5347\u7ea7<\/td><td>\u65b0\u7248\u300a\u5bb6\u7528\u71c3\u6c14\u5feb\u901f\u70ed\u6c34\u5668\u80fd\u6548\u9650\u5b9a\u503c\u53ca\u80fd\u6548\u7b49\u7ea7\u300b2025\u5e74\u5b9e\u65bd\uff0c\u6dd8\u6c70\u4f4e\u6548\u4ea7\u80fd<\/td><\/tr><tr><td>\u4ee5\u65e7\u6362\u65b0\u7ea2\u5229<\/td><td>2024\u5e74\u56fd\u5bb6\u53d1\u6539\u59d4\u5bf9\u4e00\u7ea7\u80fd\u6548\u91c7\u6696\u8bbe\u5907\u63d0\u4f9b\u6700\u9ad813%\u8865\u8d34<\/td><\/tr><tr><td>\"\u597d\u623f\u5b50\"\u653f\u7b56<\/td><td>\u4f4f\u5efa\u90e8\u660e\u786e\u5c06\"\u70ed\u6cf5\u7a7a\u8c03\"\u5217\u4e3a\u6539\u5584\u578b\u4f4f\u5b85\u91cd\u70b9\u63a8\u5e7f\u6280\u672f\uff1b\u5e7f\u5dde\u8981\u6c42\u65b0\u5efa\u4f4f\u5b85\"\u5b9c\u914d\u7f6e\u7a7a\u6c14\u6e90\u70ed\u6cf5\u5236\u5907\u751f\u6d3b\u70ed\u6c34\"<\/td><\/tr><tr><td>\u5b58\u91cf\u6362\u65b0\u9ad8\u5cf0<\/td><td>\u5168\u56fd\u91c7\u6696\u8bbe\u5907\u4fdd\u6709\u91cf\u8d854\u4ebf\u53f0\uff0c8-10\u5e74\u6362\u65b0\u5468\u671f\uff0c2025\u5e74\u8d77\u6362\u65b0\u9700\u6c42\u89c4\u6a21\u8fbe800\u4ebf\u5143\/\u5e74<\/td><\/tr><tr><td>\u7164\u6539\u7535\u6301\u7eed\u63a8\u8fdb<\/td><td>\u5317\u65b9\u5730\u533a\u7164\u6539\u7535\u653f\u7b56\u6301\u7eed\u52a0\u7801\uff0c\u7a7a\u6c14\u80fd\u70ed\u6cf5\u91c7\u6696\u8865\u8d34\u529b\u5ea6\u52a0\u5927<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 id=\"dnxt0705\" class=\"wp-block-heading\">7.5 \u603b\u7ed3\u4e0e\u5efa\u8bae<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u5bf9\u666e\u901a\u7528\u6237\u7684\u5efa\u8bae<\/strong>\uff1a<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u77ed\u671f\uff081-3\u5e74\uff09<\/strong>\uff1a\u5728\u9009\u8d2d\u5730\u6696\u7cfb\u7edf\u65f6\uff0c\u5e94\u4f18\u5148\u8003\u8651<strong>\u5e26\u6709Wi-Fi\u529f\u80fd\u3001\u53ef\u4e0e\u4e3b\u6d41\u667a\u80fd\u5bb6\u5c45\u5e73\u53f0\uff08\u5982\u82f9\u679cHomeKit\u3001\u534e\u4e3a\u9e3f\u8499\u7b49\uff09\u8054\u52a8<\/strong>\u7684\u6e29\u63a7\u5668\u548c\u70ed\u6e90\u3002\u8fd9\u662f\u8d70\u5411\u667a\u80fd\u5316\u7684\u7b2c\u4e00\u6b65\uff0c\u6210\u672c\u589e\u52a0\u4e0d\u591a\uff0c\u4f46\u4f53\u9a8c\u63d0\u5347\u660e\u663e\u3002<\/li>\n\n<li><strong>\u4e2d\u671f\uff083-5\u5e74\uff09<\/strong>\uff1a\u5982\u679c\u9884\u7b97\u5141\u8bb8\uff0c\u53ef\u4ee5\u63d0\u524d\u5e03\u5c40\u4e0e\u201c\u4e94\u6052\u201d\u7cfb\u7edf\u76f8\u5173\u7684\u7ba1\u7ebf\u63a5\u53e3\uff0c\u6bd4\u5982\u5728\u65b0\u98ce\u3001\u9664\u6e7f\u3001\u6e29\u6e7f\u5ea6\u72ec\u7acb\u63a7\u5236\u7b49\u65b9\u9762\u9884\u7559\u7a7a\u95f4\u3002\u8fd9\u5bf9\u4e8e\u672a\u6765\u5347\u7ea7\u5230\u201c\u88ab\u52a8\u623f\u201d\u6216\u201c\u597d\u623f\u5b50\u201d\u6807\u51c6\u975e\u5e38\u6709\u5229\u3002<\/li>\n\n<li><strong>\u957f\u671f\uff085\u5e74\u4ee5\u4e0a\uff09<\/strong>\uff1a<strong>\u201c\u516b\u9002\u201d\u6982\u5ff5<\/strong>\u5c06\u6210\u4e3a\u4e00\u4e2a\u660e\u786e\u7684\u8d2d\u623f\u548c\u88c5\u4fee\u6807\u51c6\u3002\u5c4a\u65f6\uff0c\u90a3\u4e9b\u80fd\u63d0\u4f9b\u201c\u5168\u5c4b\u5168\u611f3.0\u201d\u7ea7\u522b\u667a\u80fd\u5316\u89e3\u51b3\u65b9\u6848\u7684\u7ecf\u9500\u5546\u548c\u670d\u52a1\u5546\uff0c\u5c06\u62e5\u6709\u66f4\u5f3a\u7684\u7ade\u4e89\u529b\u3002<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u8ba4\u77e5<\/strong>\uff1a\u6280\u672f\u6f14\u8fdb\u7684\u6839\u672c\u76ee\u7684\u662f\u8ba9\u7cfb\u7edf\u4ece\u201c\u5de5\u5177\u201d\u53d8\u6210\u201c\u7ba1\u5bb6\u201d\u3002\u672a\u6765\u6700\u597d\u7684\u5730\u6696\u7cfb\u7edf\uff0c\u662f\u90a3\u4e2a\u201c\u8ba9\u4f60\u611f\u89c9\u4e0d\u5230\u5b83\u7684\u5b58\u5728\uff0c\u4f46\u5374\u65f6\u523b\u5904\u4e8e\u6700\u8212\u9002\u72b6\u6001\u201d\u7684\u7cfb\u7edf\u3002<\/p>\n\n<h2 id=\"dnxt08\" class=\"wp-block-heading\">\u7b2c\u516b\u7ae0\uff1a\u9009\u8d2d\u4e0e\u7ef4\u62a4\u5b9e\u7528\u624b\u518c<\/h2>\n\n<p class=\"wp-block-paragraph\">\u5728\u524d\u4e03\u7ae0\u4e2d\uff0c\u6211\u4eec\u7cfb\u7edf\u5730\u8bb2\u89e3\u4e86\u5730\u6696\u4ece\u539f\u7406\u3001\u75db\u70b9\u3001\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u3001\u63a7\u5236\u5230\u54c1\u724c\u548c\u6848\u4f8b\u7684\u5b8c\u6574\u77e5\u8bc6\u3002\u8fd9\u4e00\u7ae0\uff0c\u6211\u4eec\u5c06\u628a\u8fd9\u4e9b\u77e5\u8bc6\u6d53\u7f29\u4e3a\u4e00\u4efd\u53ef\u76f4\u63a5\u7528\u4e8e\u6307\u5bfc\u884c\u52a8\u7684<strong>\u9009\u8d2d\u4e0e\u7ef4\u62a4\u5b9e\u7528\u624b\u518c<\/strong>\uff0c\u5e2e\u52a9\u7528\u6237\u4ece\u201c\u6211\u8be5\u600e\u4e48\u505a\uff1f\u201d\u5230\u201c\u6211\u8be5\u5982\u4f55\u8ba9\u5b83\u7528\u5f97\u66f4\u4e45\u3001\u66f4\u7701\uff1f\u201d\u3002<\/p>\n\n<h3 id=\"dnxt0801\" class=\"wp-block-heading\">8.1 \u9009\u8d2d\u5168\u6d41\u7a0b\u4e00\u89c8\u56fe<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5730\u6696\u9009\u8d2d\u4e0d\u5e94\u662f\u4e00\u65f6\u51b2\u52a8\u7684\u51b3\u5b9a\uff0c\u800c\u5e94\u662f\u4e00\u4e2a\u6709\u7ae0\u53ef\u5faa\u7684\u7cfb\u7edf\u5316\u8fc7\u7a0b\u3002\u4ee5\u4e0b\u6d41\u7a0b\u5c06\u5e2e\u52a9\u7528\u6237\u505a\u51fa\u7406\u6027\u3001\u5b89\u5fc3\u7684\u9009\u62e9\u3002<\/p>\n\n<pre class=\"wp-block-preformatted\"><img decoding=\"async\" src=\"blob:https:\/\/longmai-nt.com\/adf37213-0e5d-42e9-b67a-5ce6b691ced8\"><\/pre>\n\n<p class=\"wp-block-paragraph\"><strong>\u6838\u5fc3\u8ba4\u77e5<\/strong>\uff1a\u7528\u6237\u5f80\u5f80\u5728\u7b2c\u4e09\u6b65\u5c31\u6025\u4e8e\u5b9a\u54c1\u724c\u548c\u4ef7\u683c\uff0c\u800c\u5ffd\u7565\u4e86\u7b2c\u4e00\u6b65\u548c\u7b2c\u4e8c\u6b65\u7684\u7cfb\u7edf\u6027\u9700\u6c42\u5206\u6790\u3002\u6700\u7a33\u59a5\u7684\u6d41\u7a0b\u662f<strong>\u5148\u5b9a\u7cfb\u7edf\uff0c\u518d\u5b9a\u70ed\u6e90\uff0c\u6700\u540e\u786e\u5b9a\u54c1\u724c\u4e0e\u670d\u52a1\u5546<\/strong>\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u9884\u7b97\u53c2\u8003\uff08\u542b\u5b89\u88c5\uff0c2026\u5e74\u9f99\u8109\u6696\u901a\u670d\u52a1\u62a5\u4ef7\uff09<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9762\u79ef<\/th><th>\u5e38\u89c4\u71c3\u6c14\u58c1\u6302\u7089<\/th><th>\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b<\/th><th>\u53d1\u70ed\u7535\u7f06<\/th><\/tr><\/thead><tbody><tr><td>30\u33a1\uff08\u5c40\u90e8\uff09<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u7ea63,000-5,000\u5143<\/td><\/tr><tr><td>80\u33a1<\/td><td>\u7ea61.5-2.0\u4e07\u5143<\/td><td>\u7ea62.5-3.5\u4e07\u5143<\/td><td>\u7ea68,000-16,000\u5143<\/td><\/tr><tr><td>120\u33a1<\/td><td>\u7ea61.8-2.5\u4e07\u5143<\/td><td>\u7ea63.0-4.0\u4e07\u5143<\/td><td>\u7ea612,000-25,000\u5143<\/td><\/tr><tr><td>180\u33a1<\/td><td>\u7ea62.5-3.5\u4e07\u5143<\/td><td>\u7ea64.0-5.5\u4e07\u5143<\/td><td>\u2014<\/td><\/tr><tr><td>250\u33a1<\/td><td>\u7ea63.5-5.0\u4e07\u5143<\/td><td>\u7ea65.5-7.5\u4e07\u5143<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u8865\u5145\uff1a\u9f99\u8109\u5730\u6696\u5957\u9910\u63d0\u4f9b\u56db\u6863\u6807\u51c6\u5316\u65b9\u6848\uff0899\/119\/155\/179\u5143\/\u33a1\uff09\uff0c\u542b\u8bbe\u8ba1\u3001\u65bd\u5de5\u3001\u4e3b\u6750\u4e0e\u8f85\u6750\uff0c\u5b9e\u9645\u4ef7\u683c\u56e0\u6237\u578b\u3001\u9009\u6750\u548c\u7cfb\u7edf\u590d\u6742\u5ea6\u800c\u5f02\uff0c\u9700\u8054\u7cfb\u65b9\u6848\u987e\u95ee\u83b7\u53d6\u4e13\u5c5e\u62a5\u4ef7\u3002<\/p>\n<\/blockquote>\n\n<div style=\"background:#f8f8f6;padding:22px;border-radius:12px;margin:40px 0;\">\n<h3>\u66f4\u591a\u6696\u901a\u6848\u4f8b\u53c2\u8003<\/h3>\n<p style=\"margin:8px 0;\">\n<a href=\"https:\/\/longmai-nt.com\/?page_id=2297\">\u5168\u5c0f\u533a\u5b9e\u666f\u6848\u4f8b\u805a\u5408\u9875<\/a>\uff5c\n<a href=\"https:\/\/longmai-nt.com\/?page_id=5849\">\u4e0a\u5343\u5957\u6237\u578b\u6696\u901a\u65b9\u6848\u5e93<\/a>\uff5c\n<a href=\"https:\/\/longmai-nt.com\/?page_id=3147\">\u6bcf\u65e5\u66f4\u65b0\u5b8c\u5de5\u6848\u4f8b<\/a>\uff5c\n<a href=\"https:\/\/longmai-nt.com\/?page_id=3023\">\u5168\u7ad9\u7ad9\u70b9\u5730\u56fe<\/a>\n<\/p>\n<hr style=\"margin:16px 0;border:none;border-top:1px solid #ddd;\">\n<p><strong>\u6210\u90fd\u5730\u6696\u4e0a\u95e8\u52d8\u6d4b\u670d\u52a1<\/strong>\uff1a\u9ad8\u65b0\u533a\u5357\u5bcc\u68ee\u3001\u6210\u534e\u5317\u5bcc\u68ee\u53cc\u95e8\u5e97\uff0c\u9f99\u6cc9\/\u53cc\u6d41\/\u6b66\u4faf\u5168\u57df\u514d\u8d39\u6237\u578b\u70ed\u8d1f\u8377\u6d4b\u7b97\uff0c\u54a8\u8be2\u70ed\u7ebf\uff1a028-86131795<\/p>\n<\/div>\n\n<h3 id=\"dnxt0802\" class=\"wp-block-heading\">8.2 \u6838\u5fc3FAQ\uff08\u7528\u6237\u6700\u5173\u5fc3\u768420\u4e2a\u95ee\u9898\uff09<\/h3>\n\n<p class=\"wp-block-paragraph\">\u6839\u636e\u300a\u5ba2\u6237\u6210\u529f\u6559\u7ec3\u77e5\u8bc6\u5e93\u300b\u53ca\u9500\u552e\u5b9e\u6218\u7ecf\u9a8c\uff0c\u4ee5\u4e0b\u662f\u7528\u6237\u5728\u5730\u6696\u65b9\u6848\u51b3\u7b56\u8fc7\u7a0b\u4e2d\u6700\u53ef\u80fd\u63d0\u51fa\u7684\u6838\u5fc3\u95ee\u9898\u53ca\u5176\u6807\u51c6\u53c2\u8003\u7b54\u590d\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u95ee\u9898\u5206\u7c7b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6807\u51c6\u53c2\u8003\u7b54\u590d<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>1. \u6211\u8be5\u9009\u71c3\u6c14\u9505\u7089\u8fd8\u662f\u7a7a\u6c14\u80fd\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd9\u53d6\u51b3\u4e8e\u60a8\u5bb6\u7684<strong>\u6c14\u6e90\u3001\u9762\u79ef\u548c\u957f\u671f\u5c45\u4f4f\u89c4\u5212<\/strong>\u3002\u6709\u5929\u7136\u6c14\u4e14\u8ffd\u6c42\u4f4e\u521d\u88c5\u3001\u9ad8\u8212\u9002\u5ea6\u7684\u5bb6\u5ead\u53ef\u9009\u9ad8\u6548\u51b7\u51dd\u7089\uff1b\u82e5\u8ffd\u6c42\u6781\u4f4e\u8fd0\u884c\u8d39\uff08\u6bd4\u71c3\u6c14\u770140-60%\uff09\u3001\u957f\u671f\u81ea\u4f4f\uff0c\u7a7a\u6c14\u80fd\u662f\u66f4\u4f18\u9009\u62e9\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>2. \u51b7\u51dd\u7089\u662f\u4e0d\u662f\u4e00\u5b9a\u6bd4\u666e\u901a\u7089\u597d\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e0d\u4e00\u5b9a\u3002<\/strong> \u51b7\u51dd\u7089\u5fc5\u987b\u5728<strong>\u4f4e\u6e29\u7cfb\u7edf\uff08\u6c34\u6e29\u226455\u2103\uff09<\/strong> \u4e0b\u624d\u80fd\u53d1\u6325\u5176\u70ed\u6548\u7387\u4f18\u52bf\u3002\u5982\u679c\u60a8\u5bb6\u914d\u5957\u7684\u662f\u4f20\u7edf\u6696\u6c14\u7247\uff08\u9ad8\u6e29\uff09\uff0c\u90a3\u4e48\u51b7\u51dd\u7089\u7684\u8282\u80fd\u4f18\u52bf\u65e0\u6cd5\u4f53\u73b0\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>3. \u5730\u6696\u76d8\u7ba1\u662f16\u7ba1\u597d\u8fd8\u662f20\u7ba1\u597d\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>20\u7ba1\uff08De20\uff09\u66f4\u4f18\uff0c\u4f46\u4ee3\u4ef7\u662f\u589e\u52a0\u6210\u672c\u3002<\/strong> 16\u7ba1\u65bd\u5de5\u65b9\u4fbf\uff0c\u9002\u7528\u4e8e100\u33a1\u4ee5\u4e0b\u5c0f\u6237\u578b\uff1b20\u7ba1\u7ba1\u5f84\u66f4\u5927\u3001\u5835\u7684\u98ce\u9669\u66f4\u5c0f\u3001\u6bcf\u56de\u8def\u53ef\u76d8\u66f4\u957f\u7684\u7ba1\uff0c\u66f4\u9002\u5408\u5927\u5e73\u5c42\u548c\u522b\u5885\u3002<strong>\u5e38\u88ab\u5ffd\u89c6\u7684\u4e00\u70b9\u662f\uff1a20\u7ba1\u7684\u201c\u5927\u6d41\u91cf\u3001\u5c0f\u6e29\u5dee\u201d\u53ef\u4ee5\u8ba9\u7cfb\u7edf\u66f4\u7a33\u5b9a\uff0c\u662f\u6bd4\u201c\u5bc6\u94fa\u201d\u66f4\u9ad8\u7ea7\u7684\u6280\u672f\u601d\u8def\u3002<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>4. \u4e3b\u7ba1\u7528De32\u8fd8\u662fDe25\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f18\u5148\u7528De32\u3002<\/strong> \u5f88\u591a\u7cfb\u7edf\u95ee\u9898\uff08\u5982\u672b\u7aef\u4e0d\u70ed\u3001\u9505\u7089\u566a\u97f3\u5927\uff09\u90fd\u6e90\u4e8e\u201c\u4e3b\u7ba1\u592a\u7ec6\uff0c\u8fd0\u529b\u4e0d\u8db3\u201d\u3002De32\u7684\u622a\u9762\u79ef\u662fDe25\u76841.6\u500d\uff0c\u6d41\u91cf\u63d0\u534760%\u4ee5\u4e0a\uff0c\u80fd\u663e\u8457\u6539\u5584\u6c34\u529b\u5e73\u8861\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>5. \u5730\u6696\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u5f02\u8fd9\u4e48\u5927\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u62a5\u4ef7\u5dee\u5f02\u4e3b\u8981\u4f53\u73b0\u5728\uff1a<br>1. <strong>\u9505\u7089\u578b\u53f7<\/strong>\uff08\u51b7\u51dd\u7089&gt;\u5e38\u89c4\u7089\uff09<br>2. <strong>\u8f85\u6750\u54c1\u724c<\/strong>\uff08\u767d\u6676\u677f\/\u5168\u94dd\u53cd\u5c04\u819c &gt; \u666e\u901a\u6324\u5851\u677f\/\u9540\u94dd\u819c\uff09<br>3. <strong>\u63a7\u5236\u7cfb\u7edf<\/strong>\uff08\u8054\u52a8\u63a7\u5236\u5668 &gt; \u65e0\u8054\u52a8\uff09<br>4. <strong>\u65bd\u5de5\u6807\u51c6<\/strong>\uff08\u6c2e\u6c14\u4fdd\u710a\u3001\u6253\u538b\u6d4b\u8bd5\u7b49\u5de5\u827a\uff0c\u597d\u7684\u65bd\u5de5\u65b9\u6210\u672c\u66f4\u9ad8\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>6. \u6211\u5bb6\u5c0f\u6237\u578b\uff0c\u5730\u6696\u4f1a\u4e0d\u4f1a\u5f88\u8d39\u6c14\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u53ea\u8981\u8bbe\u8ba1\u5f97\u5f53\uff08\u8d1f\u8377\u8ba1\u7b97\u51c6\u786e\u3001\u529f\u7387\u5339\u914d\u3001\u8054\u52a8\u63a7\u5236\uff09\uff0c\u5c0f\u6237\u578b\u7684\u5730\u6696\u8fd0\u884c\u8d39\u5b8c\u5168\u53ef\u63a7\u3002<strong>\u9891\u7e41\u542f\u505c\u624d\u662f\u8d39\u6c14\u7684\u5143\u51f6<\/strong>\uff0c\u8fd9\u4e0e\u6237\u578b\u5927\u5c0f\u65e0\u76f4\u63a5\u5173\u7cfb\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>7. \u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u600e\u4e48\u89e3\u51b3\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u89e3\u51b3\u65b9\u6848\u662f\uff1a<br>1. <strong>\u6362\u6210\u51b7\u51dd\u7089<\/strong>\uff08\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u66f4\u4f4e\uff09<br>2. <strong>\u589e\u52a0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236<\/strong>\uff08\u8ba9\u9505\u7089\u6536\u5230\u5ba4\u6e29\u8fbe\u6807\u4fe1\u53f7\u540e\u505c\u6b62\uff09<br>3. <strong>\u5927\u6d41\u91cf\u8bbe\u8ba1<\/strong>\uff08\u8ba9\u70ed\u91cf\u66f4\u5feb\u88ab\u8fd0\u8d70\uff0c\u5ef6\u957f\u71c3\u70e7\u65f6\u957f\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>8. \u5730\u6696\u76d8\u7ba1\u5730\u4e0a\u6709\u5f88\u591a\u7ba1\u5361\uff0c\u4f1a\u4e0d\u4f1a\u7834\u574f\u4fdd\u6e29\u5c42\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f18\u8d28\u7684\u5730\u6696\u65bd\u5de5\u4f1a\u4f7f\u7528<strong>\u73af\u4fdd\u5361\u9489<\/strong>\uff0c\u5b83\u80fd\u7262\u7262\u56fa\u5b9a\u7ba1\u9053\uff0c\u540c\u65f6\u4e0d\u4f1a\u523a\u7a7f\u4fdd\u6e29\u677f\u5e95\u90e8\u7684\u805a\u82ef\u4e59\u70ef\u6ce1\u6cab\u5c42\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>9. \u5730\u6696\u56de\u586b\u5c42\u8981\u591a\u4e45\u624d\u80fd\u5e72\u900f\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6b63\u5e38\u517b\u62a4\u9700\u8981<strong>7\u5929<\/strong>\uff08\u81ea\u7136\u517b\u62a4\uff09\uff0c\u671f\u95f4\u4e25\u7981\u8e29\u8e0f\u548c\u642c\u8fd0\u91cd\u7269\u30027\u5929\u540e\u53ef\u8fdb\u884c\u5730\u9762\u627e\u5e73\u65bd\u5de5\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>10. \u5730\u6696\u7cfb\u7edf\u80fd\u7528\u591a\u4e45\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5730\u6696\u76d8\u7ba1\uff08\u9690\u853d\u5de5\u7a0b\uff09\u5bff\u547d\u53ef\u8fbe<strong>50\u5e74<\/strong>\uff08\u963b\u6c27\u7ba1\u914d\u5408\u7cfb\u7edf\u7ef4\u62a4\uff09\u3002<br>\u58c1\u6302\u7089\u5bff\u547d\u7ea6<strong>10-15\u5e74<\/strong>\u3002<br>\u7a7a\u6c14\u80fd\u4e3b\u673a\u8bbe\u8ba1\u5bff\u547d\u7ea6<strong>20\u5e74<\/strong>\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>11. \u5730\u6696\u8981\u591a\u4e45\u6e05\u6d17\u4e00\u6b21\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6bcf2-3\u5e74<\/strong>\u6e05\u6d17\u4e00\u6b21\u5730\u6696\u7ba1\u3002\u5982\u679c\u53d1\u73b0\u7cfb\u7edf\u6c34\u5448\u9ed1\u8272\u6216\u94c1\u9508\u8272\uff0c\u9700\u7acb\u5373\u6e05\u6d17\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>12. \u6696\u6c14\u7247\u548c\u5730\u6696\u80fd\u6df7\u7528\u5417\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5b8c\u5168\u4e0d\u5efa\u8bae\u3002<\/strong> \u56e0\u4e3a\u4e24\u8005\u5bf9\u6c34\u6e29\u8981\u6c42\u5b8c\u5168\u4e0d\u540c\u3002\u6df7\u5408\u4f7f\u7528\u4f1a\u5bfc\u81f4\u7cfb\u7edf\u6c34\u529b\u5931\u8861\uff0c\u6548\u679c\u5927\u6253\u6298\u6263\uff0c\u4e14\u589e\u52a0\u63a7\u5236\u96be\u5ea6\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>13. \u5730\u6696\u5206\u6c34\u5668\u88c5\u5728\u54ea\u91cc\u6700\u597d\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u6c34\u5668\u5e94\u5b89\u88c5\u5728<strong>\u536b\u751f\u95f4\u3001\u53a8\u623f\u6216\u9633\u53f0<\/strong>\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u3002<strong>\u5207\u5fcc<\/strong>\u5c06\u5176\u5b89\u88c5\u5728\u5ba2\u5385\u6216\u5367\u5ba4\u5730\u9762\uff0c\u5426\u5219\u4e00\u65e6\u6f0f\u6c34\u4f1a\u9020\u6210\u91cd\u5927\u635f\u5931\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>14. \u4ec0\u4e48\u662f\u201c\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u201d\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd9\u662f\u4e00\u4e2a<strong>\u975e\u5e38\u4e13\u4e1a\u4e14\u5fc5\u8981\u7684\u8bbe\u8ba1<\/strong>\uff0c\u6307\u7528\u4e00\u4e2a\u72ec\u7acb\u7684\u70ed\u6c34\u5668\uff08\u71c3\u6c14\u6216\u7535\uff09\u4f9b\u5e94\u751f\u6d3b\u70ed\u6c34\uff0c\u800c\u5730\u6696\u58c1\u6302\u7089\u53ea\u8d1f\u8d23\u91c7\u6696\u3002\u8fd9\u6837\u505a\u5f7b\u5e95\u907f\u514d\u4e86\u201c\u5927\u9a6c\u62c9\u5c0f\u8f66\u201d\u548c\u201c\u590f\u5929\u8fc7\u70eb\u201d\u7684\u95ee\u9898\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>15. \u6211\u5bb6\u6709\u5730\u6696\uff0c\u4e0a\u9762\u80fd\u6446\u653e\u5927\u4ef6\u5bb6\u5177\u5417\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53ef\u4ee5\uff0c\u4f46\u8981\u6ce8\u610f<\/strong>\uff1a<br>1. \u65e0\u817f\u5bb6\u5177\uff08\u5982\u843d\u5730\u6c99\u53d1\uff09\u4e0b\u65b9\u4e0d\u5efa\u8bae\u94fa\u8bbe\u5730\u6696\u7ba1\uff0c\u4ee5\u9632\u70ed\u91cf\u6563\u4e0d\u51fa\u3002<br>2. \u6709\u817f\u5bb6\u5177\uff08\u5982\u5e8a\u3001\u8863\u67dc\uff09\u4e0b\u65b9\u53ef\u4ee5\u94fa\uff0c\u4f46\u8981\u786e\u4fdd\u5730\u9762\u6e29\u5ea6\u5747\u5300\uff0c\u4e0d\u5f71\u54cd\u6563\u70ed\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>16. \u5730\u6696\u9700\u8981\u548c\u4e2d\u592e\u7a7a\u8c03\u8054\u52a8\u5417\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u975e\u5e38\u63a8\u8350\u3002<\/strong> \u5982\u679c\u5b89\u88c5\u4e86<strong>\u5929\u6c1f\u5730\u6c34\u6216\u5929\u6c34\u5730\u6c34<\/strong>\u7cfb\u7edf\uff0c\u53ef\u4ee5\u901a\u8fc7\u4e00\u4e2a<strong>11\u5bf8AI\u667a\u6167\u96c6\u63a7\u5c4f<\/strong>\u5b9e\u73b0\u5bf9\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u51c0\u5316\u7b49\u8bbe\u5907\u7684\u7edf\u4e00\u7ba1\u7406\u548c\u573a\u666f\u8054\u52a8\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>17. \u5730\u6696\u7cfb\u7edf\u9700\u8981\u5b9a\u671f\u4fdd\u517b\u5417\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u662f\u7684\uff0c\u9700\u8981\u3002<\/strong> \u6bcf\u5e74\u4f9b\u70ed\u7ed3\u675f\u540e\uff0c\u5e94\u8fdb\u884c\u7b80\u5355\u7684\u7cfb\u7edf\u68c0\u67e5\uff1b\u6bcf2-3\u5e74\u5e94\u5bf9\u7ba1\u9053\u8fdb\u884c\u4e00\u6b21\u4e13\u4e1a\u6e05\u6d17\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>18. \u5730\u6696\u5730\u9762\u51fa\u73b0\u88c2\u7f1d\u600e\u4e48\u529e\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5982\u679c\u88c2\u7f1d\u975e\u5e38\u7ec6\u5c0f\uff08&lt;0.5mm\uff09\uff0c\u901a\u5e38\u4e0d\u5f71\u54cd\u4f7f\u7528\uff0c\u53ea\u9700\u7528\u7f8e\u7f1d\u5242\u4fee\u8865\u5373\u53ef\u3002\u5982\u679c\u88c2\u7f1d\u8f83\u5927\u6216\u4f34\u6709\u7a7a\u6d1e\u58f0\uff0c\u9700\u8bf7\u4e13\u4e1a\u4eba\u5458\u68c0\u67e5\u56de\u586b\u5c42\u662f\u5426\u7a7a\u9f13\uff0c\u5e76\u53ca\u65f6\u4fee\u590d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>19. \u5730\u6696\u94fa\u597d\u540e\uff0c\u4e0a\u9762\u8fd8\u80fd\u505a\u6728\u5730\u677f\u5417\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53ef\u4ee5\u3002<\/strong> \u5e94\u9009\u7528<strong>\u5730\u6696\u4e13\u7528\u5b9e\u6728\u590d\u5408\u5730\u677f<\/strong>\u6216<strong>\u5f3a\u5316\u590d\u5408\u5730\u677f<\/strong>\u3002\u9700\u6ce8\u610f\uff1a\u5730\u6696\u4f9b\u6c34\u6e29\u5ea6\u4e0d\u5b9c\u8d85\u8fc745\u2103\uff0c\u4e14\u6728\u5730\u677f\u5e94\u94fa\u8bbe\u4f38\u7f29\u7f1d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>20. \u56fd\u4ea7\u9505\u7089\u548c\u8fdb\u53e3\u9505\u7089\u5dee\u522b\u5927\u5417\uff1f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u5dee\u5f02\u5728\u4e8e<strong>\u63a7\u5236\u903b\u8f91\u548c\u957f\u671f\u7a33\u5b9a\u6027<\/strong>\u3002\u8fdb\u53e3\u54c1\u724c\uff08\u5982\u83f2\u65af\u66fc\u3001\u535a\u4e16\uff09\u5728\u71c3\u70e7\u63a7\u5236\u3001\u5b89\u5168\u4fdd\u62a4\u3001\u70ed\u4ea4\u6362\u6548\u7387\u7b49\u65b9\u9762\u6280\u672f\u79ef\u7d2f\u66f4\u6df1\u3002\u4f46\u56fd\u4ea7\u9505\u7089\uff08\u5982\u6d77\u5c14\u3001\u7f8e\u7684\uff09\u8fd1\u5e74\u5728\u6027\u4ef7\u6bd4\u548c\u672c\u5730\u5316\u670d\u52a1\u4e0a\u8fdb\u6b65\u5f88\u5feb\u3002<strong>\u5efa\u8bae\u4ed4\u7ec6\u7814\u8bfb\u4ea7\u54c1\u624b\u518c\u548c\u8bc4\u4ef7\u3002<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u5e38\u89c1\u8bef\u533a\uff088\u6761\uff09<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u8bef\u533a<\/th><th>\u6b63\u786e\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td>\"\u4e70\u5927\u529f\u7387\u9505\u7089\uff0c\u91c7\u6696\u66f4\u7ed9\u529b\"<\/td><td>\u529f\u7387\u8d8a\u5927\uff0c\u6700\u5c0f\u8f93\u51fa\u8d8a\u5927\uff0c\u5c0f\u9762\u79ef\u53cd\u800c\u9891\u7e41\u542f\u505c\u3002\u529f\u7387\u5339\u914d\u6bd4\u529f\u7387\u5927\u66f4\u91cd\u8981<\/td><\/tr><tr><td>\"\u51b7\u51dd\u7089\u5f88\u7701\u6c14\uff0c\u4e70\u5b83\u5c31\u5bf9\u4e86\"<\/td><td>\u6709\u524d\u63d0\uff1a\u5fc5\u987b\u4f4e\u6e29\u8fd0\u884c\uff08\u914d\u5730\u6696\u6216\u4f4e\u6e29\u6696\u6c14\u7247\uff09\u3002\u914d\u4f20\u7edf\u6696\u6c14\u7247=\u767d\u4e70<\/td><\/tr><tr><td>\"\u7a7a\u6c14\u80fd\u51ac\u5929\u4e0d\u70ed\uff0c\u5317\u65b9\u4e0d\u80fd\u7528\"<\/td><td>\u8865\u6c14\u589e\u7113\u673a\u578b-25\u2103\u4ecd\u53ef\u8fd0\u884c\u3002\u5173\u952e\u662f\u9009\u5bf9\u673a\u578b\uff0c\u4e0d\u662f\u6280\u672f\u672c\u8eab\u4e0d\u884c<\/td><\/tr><tr><td>\"\u7535\u5730\u6696\u8f90\u5c04\u5927\uff0c\u5bf9\u8eab\u4f53\u4e0d\u597d\"<\/td><td>\u53cc\u5bfc\u53d1\u70ed\u7535\u7f06\u53ef\u62b5\u6d88\u78c1\u573a\uff0c\u5408\u683c\u4ea7\u54c1\u7535\u78c1\u8f90\u5c04\u8fdc\u4f4e\u4e8e\u56fd\u6807\u5b89\u5168\u9650\u503c<\/td><\/tr><tr><td>\"\u77f3\u58a8\u70ef\u5730\u6696\u662f\u9ed1\u79d1\u6280\uff0c\u6bd4\u666e\u901a\u7535\u5730\u6696\u7701\u7535\"<\/td><td>\u7535\u5730\u6696\u6c38\u8fdc\u662f1\u5ea6\u7535=1\u5ea6\u70ed\uff0c\u80fd\u6548\u6bd4\u4e0d\u53ef\u80fd\u7a81\u7834\u7269\u7406\u5b9a\u5f8b\u3002\"\u77f3\u58a8\u70ef\"\u662f\u8425\u9500\u6982\u5ff5<\/td><\/tr><tr><td>\"\u5730\u6696\u7ba1\u9053\u4e0d\u7528\u963b\u6c27\u7ba1\uff0c\u666e\u901a\u7ba1\u5c31\u884c\"<\/td><td>5\u5143\u7684\u963b\u6c27\u7ba1\u5dee\u4ef7\uff0c5\u5e74\u540e\u53ef\u80fd\u7701\u4e0b\u51e0\u5343\u5143\u7684\u7ba1\u9053\u6e05\u6d17\u8d39<\/td><\/tr><tr><td>\"\u5730\u6696\u4e0a\u9762\u94fa\u5b9e\u6728\u5730\u677f\uff0c\u663e\u6863\u6b21\"<\/td><td>\u5b9e\u6728\u5730\u677f\u5bfc\u70ed\u5dee+\u6613\u53d8\u5f62\uff0c\u5730\u6696\u6548\u679c\u5927\u6253\u6298\u6263\u3002\u74f7\u7816\/\u590d\u5408\u5730\u677f\u624d\u662f\u6b63\u89e3<\/td><\/tr><tr><td>\"\u88c5\u4fee\u5b8c\u4e86\u8fd8\u80fd\u52a0\u5730\u6696\"<\/td><td>\u6e7f\u94fa\u6c34\u5730\u6696\u57fa\u672c\u4e0d\u53ef\u80fd\uff08\u9700\u7838\u5730\u9762\uff09\u3002\u5e72\u94fa\u53d1\u70ed\u7535\u7f06\u53ef\u884c\uff0c\u4f46\u5c42\u9ad8\u4f1a\u589e\u52a03-5mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 id=\"dnxt0803\" class=\"wp-block-heading\">8.3 \u5173\u952e\u65bd\u5de5\u9a8c\u6536\u6307\u6807<\/h3>\n\n<p class=\"wp-block-paragraph\">\u5730\u6696\u5de5\u7a0b\u662f\u201c\u4e09\u5206\u4ea7\u54c1\uff0c\u4e03\u5206\u5b89\u88c5\u201d\u3002\u4ee5\u4e0b\u662f\u6839\u636e\u300aJGJ 142-2012 \u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b\u7b49\u56fd\u5bb6\u6807\u51c6\u63d0\u70bc\u7684\u6838\u5fc3\u9a8c\u6536\u7ea2\u7ebf\u6307\u6807\uff0c\u53ef\u4f5c\u4e3a\u7528\u6237\u9a8c\u6536\u65b9\u6848\u65f6\u7684\u81ea\u67e5\u6e05\u5355\u3002<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9a8c\u6536\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6838\u5fc3\u6307\u6807<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70ed\u8d1f\u8377\u8ba1\u7b97<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7531\u670d\u52a1\u5546\u63d0\u4f9b\u8be6\u7ec6\u7684<strong>\u9010\u65f6\u8d1f\u8377\u8ba1\u7b97\u4e66<\/strong>\uff0c\u800c\u975e\u7b80\u5355\u201c\u9762\u79ef\u00d7\u6570\u5b57\u201d\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6b63\u89c4\u6d41\u7a0b\uff0c\u4e25\u7981\u201c\u7ecf\u9a8c\u4f30\u7b97\u201d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u76d8\u7ba1\u95f4\u8ddd\u4e0e\u957f\u5ea6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u76d8\u7ba1\u95f4\u8ddd\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u786e\u5b9a\uff0c<strong>\u6bcf\u4e00\u56de\u8def\u957f\u5ea6\u4e0d\u5e94\u8d85\u8fc7120m\uff0816\u7ba1\uff09\/150m\uff0820\u7ba1\uff09<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fc7\u957f\u6216\u8fc7\u5bc6\u90fd\u5f71\u54cd\u6548\u679c\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u96c6\u6c34\u5668<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5fc5\u987b\u4f7f\u7528\u5206\u96c6\u6c34\u5668<\/strong>\uff08\u7ae0\u9c7c\u5f0f\u6216\u540c\u7a0b\u5f0f\uff09\uff0c\u6bcf\u4e2a\u56de\u8def\u72ec\u7acb\u63a7\u5236\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u7981\u4f7f\u7528\u5f02\u7a0b\u7cfb\u7edf\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6253\u538b\u6d4b\u8bd5<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6ce8\u6ee1\u6c34\u540e\uff0c<strong>\u7f13\u6162\u5347\u538b\u81f30.6MPa\uff0c\u4fdd\u538b24\u5c0f\u65f6\uff0c\u538b\u964d\u22640.05MPa\u4e3a\u5408\u683c<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6240\u6709\u7ba1\u9053\u8fde\u63a5\u5904\u9700\u68c0\u6f0f\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e3b\u7ba1\u539a\u5ea6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4f18\u5148\u4f7f\u7528De32\u7ba1<\/strong>\u4f5c\u4e3a\u4e3b\u7ba1\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9632\u6b62\u4e3b\u7ba1\u8fc7\u7ec6\u5bfc\u81f4\u6c34\u5faa\u73af\u4e0d\u7545\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6392\u6c14\u9600<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf\u6700\u9ad8\u70b9\uff08\u5982\u5206\u6c34\u5668\u9876\u90e8\uff09<strong>\u5fc5\u987b\u5b89\u88c5\u81ea\u52a8\u6392\u6c14\u9600<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ea\u52a8\u6392\u653e\u7cfb\u7edf\u8fd0\u884c\u65f6\u4ea7\u751f\u7684\u6c14\u4f53\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u56de\u586b\u5c42\u517b\u62a4<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6d47\u7b51\u540e\u81ea\u7136\u517b\u62a4\u4e0d\u5c11\u4e8e7\u5929<\/strong>\uff0c\u4e25\u7981\u4f7f\u7528\u70ed\u98ce\u5e72\u71e5\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u786e\u4fdd\u56de\u586b\u5c42\u5f3a\u5ea6\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4fdd\u6e29\u677f<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u94fa\u8bbe\u4e25\u5bc6\uff0c<strong>\u63a5\u7f1d\u5904\u7528\u94dd\u7b94\u80f6\u5e26\u7c98\u63a5<\/strong>\uff1b\u4fa7\u9762\u8bbe\u7f6e<strong>\u8fb9\u89d2\u4fdd\u6e29\u6761\uff08\u226510mm\uff09<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9632\u6b62\u70ed\u91cf\u6cbf\u5899\u4f53\u6d41\u5931\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u53cd\u5c04\u819c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u63a8\u8350\u4f7f\u7528\u5168\u94dd\u53cd\u5c04\u819c<\/strong>\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6027\u80fd\u6301\u4e45\uff0c\u4e0d\u8150\u8680\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8054\u52a8\u63a7\u5236\u7cfb\u7edf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5b89\u88c5<strong>\u8054\u52a8\u63a7\u5236\u6a21\u5757\uff08\u5982\u66fc\u745e\u5fb7H-BOX\uff09<\/strong>\uff0c\u5b9e\u73b0\u201c\u5ba4\u6e29\u8fbe\u6807\u2192\u9505\u7089\u505c\u673a\u201d\u7684\u903b\u8f91\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8fd9\u662f\u8282\u80fd\u7684\u201c\u603b\u5f00\u5173\u201d\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8d28\u4fdd\u6587\u4ef6<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8981\u6c42\u63d0\u4f9b<\/strong>\uff1a\u6838\u5fc3\u8bbe\u5907\uff08\u5982\u4e3b\u673a\u3001\u9505\u7089\uff09\u7684\u5382\u5bb6\u8d28\u4fdd\u5361\u3001\u7ba1\u9053\u54c1\u724c50\u5e74\u8d28\u91cf\u4fdd\u8bc1\u4e66\u3001\u65bd\u5de5\u9a8c\u6536\u5355\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4fdd\u8bc1\u552e\u540e\u670d\u52a1\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 id=\"dnxt0804\" class=\"wp-block-heading\">8.4 \u4fdd\u517b\u65e5\u5386\u4e0e\u7ef4\u4fdd\u6e05\u5355<\/h3>\n\n<p class=\"wp-block-paragraph\">\u7cfb\u7edf\u7ef4\u62a4\u662f\u957f\u671f\u4eab\u53d7\u8212\u9002\u548c\u8282\u80fd\u7684\u4fdd\u8bc1\u3002\u6839\u636e\u300a\u91c7\u6696\u6570\u636e\u6c47\u603b\u300b\u53ca\u7ef4\u4fdd\u670d\u52a1\u5305\u5185\u5bb9\uff0c\u4ee5\u4e0b\u662f\u5730\u6696\u7cfb\u7edf\u7684\u5168\u751f\u547d\u5468\u671f\u517b\u62a4\u8ba1\u5212\u3002<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>\u9996\u6b21\u4f7f\u7528\u8bbe\u7f6e\u6307\u5357<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<ol class=\"wp-block-list\">\n<li><strong>\u7cfb\u7edf\u6ce8\u6c34\u6392\u6c14<\/strong>\uff1a\u6253\u5f00\u5404\u652f\u8def\u9600\u95e8\uff0c\u542f\u52a8\u5faa\u73af\u6cf5\uff0c\u9010\u4e2a\u652f\u8def\u6392\u6c14\u81f3\u51fa\u6c34\u8fde\u7eed\u65e0\u6c14\u6ce1<\/li>\n\n<li><strong>\u8bbe\u5b9a\u4f9b\u6c34\u6e29\u5ea6<\/strong>\uff1a\u5730\u6696\u9996\u6b21\u4f7f\u7528\u4ece30\u2103\u5f00\u59cb\uff0c\u6bcf\u5929\u53475\u2103\uff0c3-5\u5929\u5347\u81f3\u76ee\u6807\u6e29\u5ea6\uff0845\u2103\uff09\uff0c\u907f\u514d\u56de\u586b\u5c42\u5f00\u88c2<\/li>\n\n<li><strong>\u8bbe\u5b9a\u6e29\u63a7\u5668<\/strong>\uff1a\u5404\u623f\u95f4\u6309\u9700\u8bbe\u5b9a\uff08\u5367\u5ba420-22\u2103\uff0c\u5ba2\u538518-20\u2103\uff0c\u536b\u751f\u95f422-24\u2103\uff09<\/li>\n\n<li><strong>\u8054\u52a8\u63a7\u5236<\/strong>\uff1a\u786e\u8ba4\u6e29\u63a7\u5668\u4e0e\u9505\u7089\/\u70ed\u6cf5\u8054\u52a8\u6b63\u5e38\uff08\u5168\u5c4b\u8fbe\u6807\u2192\u70ed\u6e90\u964d\u529f\u7387\u6216\u505c\u673a\uff09<\/li>\n<\/ol>\n\n<h4 class=\"wp-block-heading\">8.4.1 \u5e74\u5ea6\u7ef4\u4fdd\u6e05\u5355<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u4fdd\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u63a8\u8350\u5468\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u91cd\u8981\u6027<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u7cfb\u7edf\u6c34\u8d28\u68c0\u67e5<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u653e\u6c34\u89c2\u5bdf\u989c\u8272\u3001\u6c14\u5473\uff0c\u7528PH\u8bd5\u7eb8\u68c0\u6d4b\u9178\u78b1\u5ea6\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6838\u5fc3<\/strong>\uff08\u5224\u65ad\u7cfb\u7edf\u8150\u8680\u7a0b\u5ea6\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u8fc7\u6ee4\u5668\u6e05\u6d17<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u9600\u95e8\uff0c\u62c6\u5378Y\u578b\u8fc7\u6ee4\u5668\u6ee4\u7f51\uff0c\u7528\u6e05\u6c34\u51b2\u6d17\u540e\u88c5\u56de\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6838\u5fc3<\/strong>\uff08\u9632\u6b62\u5835\u585e\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9505\u7089\/\u70ed\u6cf5\u4fdd\u517b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">1-2\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6e05\u6d17\u71c3\u70e7\u5ba4\u3001\u98ce\u673a\u53f6\u8f6e\u3001\u6e05\u7406\u79ef\u78b3\u3001\u68c0\u67e5\u70b9\u706b\u7535\u6781\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5173\u952e<\/strong>\uff08\u63d0\u5347\u70ed\u6548\u738720%\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u81a8\u80c0\u7f50\u538b\u529b\u68c0\u6d4b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7528\u80ce\u538b\u8868\u68c0\u6d4b\u9884\u5145\u538b\u529b\uff0c\u786e\u4fdd\u57281.0-1.5bar\u4e4b\u95f4\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5173\u952e<\/strong>\uff08\u9632\u6b62\u7cfb\u7edf\u5931\u538b\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5ba4\u6e29\u8054\u52a8\u529f\u80fd\u6d4b\u8bd5<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8bbe\u5b9a\u4e0d\u540c\u6e29\u5ea6\uff0c\u786e\u8ba4\u6e29\u63a7\u5668\u80fd\u6b63\u5e38\u542f\u505c\u9505\u7089\/\u70ed\u6cf5\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5173\u952e<\/strong>\uff08\u786e\u8ba4\u8282\u80fd\u529f\u80fd\u6b63\u5e38\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u76d8\u7ba1\u6e05\u6d17<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">2-3\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f7f\u7528\u4e13\u4e1a\u6e05\u6d17\u5242\u8109\u51b2\u6e05\u6d17\uff0c\u53bb\u9664\u5185\u90e8\u6c34\u57a2\u548c\u6742\u8d28\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u91cd\u8981<\/strong>\uff08\u6062\u590d\u6563\u70ed\u6548\u7387\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u70df\u9053\uff08\u5e73\u8861\u5f0f\u9505\u7089\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6bcf\u5e74<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u68c0\u67e5\u6392\u70df\u53e3\u662f\u5426\u5835\u585e\uff0c\u6e05\u9664\u79ef\u7070\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5b89\u5168<\/strong>\uff08\u9632\u6b62CO\u4e2d\u6bd2\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">8.4.2 \u56db\u5b63\u4f7f\u7528\u6307\u5357<\/h4>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5b63\u8282<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u64cd\u4f5c\u8981\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6ce8\u610f\u4e8b\u9879<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u51ac\u5b63\uff08\u4f9b\u6696\u5b63\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u5929\u5f00\u542f\uff08\u5730\u6696\u4e0d\u5b9c\u9891\u7e41\u5f00\u5173\uff0c\u6052\u6e29\u8fd0\u884c\u6bd4\u53cd\u590d\u5347\u6e29\u66f4\u7701\u80fd\uff09\uff1b\u957f\u671f\u79bb\u5bb6\u8bbe\u9632\u51bb\u6a21\u5f0f\uff088\u2103\uff09\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u786e\u4fdd\u7cfb\u7edf\u538b\u529b\u57281.0-1.5bar\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6625\u5b63\uff08\u505c\u6696\u5b63\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5173\u95ed\u91c7\u6696\u6a21\u5f0f\uff1b\u6e05\u6d17\u8fc7\u6ee4\u5668\uff1b\u68c0\u67e5\u7cfb\u7edf\u538b\u529b\uff0c\u5fc5\u8981\u65f6\u8865\u6c34\u81f31.5bar\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6253\u5f00\u6ce8\u6c34\u9600\uff0c<strong>\u7f13\u6162<\/strong>\u8865\u6c34\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u590f\u5b63<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4ec5\u7528\u70ed\u6c34\u529f\u80fd\uff08\u4e24\u7528\u7089\u8c03\u81f3\u590f\u5b63\u6a21\u5f0f\uff09\uff1b\u7a7a\u6c14\u80fd\u4e24\u8054\u4f9b\u5207\u6362\u81f3\u5236\u51b7\u6a21\u5f0f\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u82e5\u957f\u671f\u4e0d\u7528\uff0c\u5efa\u8bae\u6392\u7a7a\u7cfb\u7edf\uff08\u5c24\u5176\u8981\u9632\u51bb\uff09\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u79cb\u5b63\uff08\u4f9b\u6696\u5b63\u524d\uff09<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u91c7\u6696\u5b63\u524d\u8bd5\u8fd0\u884c\uff1b\u6392\u6c14\uff1b\u68c0\u67e5\u5faa\u73af\u6cf5\u8fd0\u8f6c\uff1b\u6e05\u6d17\u8fc7\u6ee4\u5668\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63a5\u901a\u7535\u6e90\uff0c\u9884\u70ed\u4e00\u5929\u540e\u518d\u4f7f\u7528\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h4 class=\"wp-block-heading\">8.4.3 \u7ef4\u4fdd\u670d\u52a1\u4e0e\u8d28\u4fdd\u653f\u7b56<\/h4>\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6838\u5fc3\u8d28\u4fdd<\/strong>\uff1a\u5730\u6696\u9690\u853d\u5de5\u7a0b\uff08\u7ba1\u6750\u3001\u7ba1\u4ef6\uff09\u901a\u5e38\u63d0\u4f9b<strong>50\u5e74\u8d28\u4fdd<\/strong>\uff08\u5982\u4f1f\u661f\u3001\u7eff\u7fbd\u54c1\u724c\u6388\u6743\uff09\u3002\u70ed\u6e90\u8bbe\u5907\uff08\u4e3b\u673a\/\u9505\u7089\uff09\u8d28\u4fdd\u4e00\u822c\u4e3a<strong>3-10\u5e74<\/strong>\u3002<\/li>\n\n<li><strong>\u589e\u503c\u670d\u52a1<\/strong>\uff1a\u90e8\u5206\u670d\u52a1\u5546\u63d0\u4f9b<strong>\u5e74\u5ea6\u4f1a\u5458\u5236\u7ef4\u4fdd\u670d\u52a1<\/strong>\uff0c\u5305\u542b\u5e74\u5ea6\u68c0\u67e5\u3001\u6df1\u5ea6\u6e05\u6d17\u3001\u6545\u969c\u7ef4\u4fee\u7684\u5957\u9910\u3002\u9009\u62e9\u6b64\u7c7b\u670d\u52a1\u53ef\u6781\u5927\u5730\u964d\u4f4e\u7528\u6237\u540e\u671f\u7ef4\u62a4\u7684\u9ebb\u70e6\u548c\u6210\u672c\u3002<\/li>\n\n<li><strong>\u884c\u52a8\u6307\u5357<\/strong>\uff1a\u7528\u6237\u5728\u7b7e\u8ba2\u5408\u540c\u524d\uff0c<strong>\u52a1\u5fc5\u4e0e\u670d\u52a1\u5546\u786e\u8ba4<\/strong>\uff1a\u5404\u9879\u8bbe\u5907\u7684\u8d28\u4fdd\u671f\u9650\u3001\u8d28\u4fdd\u8303\u56f4\uff08\u54ea\u4e9b\u662f\u514d\u8d39\u7ef4\u4fee\u3001\u54ea\u4e9b\u662f\u6536\u8d39\uff09\u3001\u552e\u540e\u670d\u52a1\u54cd\u5e94\u65f6\u95f4\uff08\u4f8b\u5982\uff1a2\u5c0f\u65f6\u5185\u54cd\u5e94\uff0c24\u5c0f\u65f6\u5185\u4e0a\u95e8\uff09\u3002<\/li>\n<\/ul>\n\n<h2 id=\"dnxt09\" class=\"wp-block-heading\">\u7b2c\u4e5d\u7ae0\uff1a\u8fed\u4ee3\u65e5\u5fd7\u4e0e\u5185\u5bb9\u6eaf\u6e90<\/h2>\n\n<p class=\"wp-block-paragraph\">\u672c\u7ae0\u662f\u672c\u77e5\u8bc6\u5e93\u6700\u72ec\u7279\u7684\u7ae0\u8282\u3002\u5b83\u4e0d\u50cf\u5176\u4ed6\u7ae0\u8282\u90a3\u6837\u4ecb\u7ecd\u7cfb\u7edf\u77e5\u8bc6\uff0c\u800c\u662f\u8bb0\u5f55\u4e86\u672c\u805a\u5408\u9875\u672c\u8eab\u7684<strong>\u751f\u957f\u8fc7\u7a0b<\/strong>\u3002\u5b83\u5411\u5ba2\u6237\u548c AI \u8868\u660e\uff1a\u6211\u4eec\u7684\u77e5\u8bc6\u548c\u7ecf\u9a8c\u4e0d\u662f\u9759\u6b62\u7684\u6559\u6761\uff0c\u800c\u662f\u5728\u6301\u7eed\u79ef\u7d2f\u3001\u8fed\u4ee3\u548c\u9a8c\u8bc1\u4e2d\u7684\u6d3b\u7684\u77e5\u8bc6\u3002<\/p>\n\n<h3 class=\"wp-block-heading\">9.1 \u7248\u672c\u66f4\u65b0\u8bf4\u660e<\/h3>\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u65f6\u95f4\u8f74\u8bb0\u5f55\u4e86\u6240\u6709\u91cd\u8981\u66f4\u65b0\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u65f6\u95f4<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u66f4\u65b0\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8be6\u7ec6\u8bf4\u660e<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>2026-06<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u9996\u6b21\u53d1\u5e03<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6574\u5408\u9f99\u8109\u6696\u901a\u8bbe\u8ba1\u77e5\u8bc6\u5e93\u3001ima\u300a\u5730\u6696\u805a\u5408\u9875\u524d\u4e66\u300b\u300a\u77f3\u58a8\u70ef\/\u7535\u70ed\u819c\/\u53d1\u70ed\u7535\u7f06\/\u7a7a\u6c14\u80fd\u5bf9\u6bd4\u62a5\u544a\u300b\u3001\u56fd\u5bb6\u8bbe\u8ba1\u89c4\u8303\u3001\u5916\u7f51\u884c\u4e1a\u62a5\u544a\uff0c\u5efa\u7acb\u5b8c\u6574\u5730\u6696\u7cfb\u7edf\u77e5\u8bc6\u6846\u67b6\uff0810\u7ae0\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>2026-06<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e0a\u518c\uff08\u7b2c1-5\u7ae0\uff09\u53d1\u5e03<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e24\u6761\u4e3b\u7ebf\u5e76\u884c\u6f14\u8fdb\u3001\u4e09\u5927\u70ed\u6e90\u9635\u8425\u6df1\u5ea6\u5bf9\u6bd4\u3001\u8f93\u914d\u6c34\u529b\u5e73\u8861\u3001\u672b\u7aef\u76d8\u7ba1\u4e0e\u5730\u9762\u6750\u6599\u3001\u8bbe\u8ba1\u89c4\u8303\u4e0e\u9009\u578b\u516c\u5f0f<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>2026-06<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u4e0b\u518c\uff08\u7b2c6-10\u7ae0\uff09\u53d1\u5e03<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e09\u5927\u54c1\u724c\u9635\u8425\u4f18\u9009\u6e05\u5355\u3001\u56db\u5730\u771f\u5b9e\u6848\u4f8b\u3001\u672a\u6765\u91c7\u6696\u8d8b\u52bf\u3001\u9009\u8d2d\u7ef4\u62a4\u5168\u6307\u5357\u3001\u8fed\u4ee3\u65e5\u5fd7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f85\u66f4\u65b0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u589e\u52a03\u4e2a\u6848\u4f8b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u589e\u52a02026\u5e74\u5ea6\u5ba2\u6237\u80fd\u8017\u8ddf\u8e2a\u6848\u4f8b\uff08\u542b\u7a7a\u6c14\u80fd\u957f\u5468\u671fCOP\u5b9e\u6d4b\u6570\u636e\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f85\u66f4\u65b0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u66f4\u65b0\u5e02\u573a\u6570\u636e<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6839\u636e\u6700\u65b0\u5e02\u573a\u884c\u60c5\uff0c\u66f4\u65b0\u5404\u54c1\u7c7b\u70ed\u6e90\u4ef7\u683c\u4e0e\u80fd\u8017\u5bf9\u6bd4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f85\u66f4\u65b0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u54c1\u724c\u4e13\u9898\u9875\u4e0a\u7ebf<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u3001\u83f2\u65af\u66fc\u58c1\u6302\u7089\u3001\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u3001\u6d77\u4fe1\u7a7a\u6c14\u80fd\u3001\u7ebd\u6069\u6cf0\u8d85\u4f4e\u6e29\u3001\u827e\u9ed8\u751f\u53d1\u70ed\u7535\u7f06\u7b49\u54c1\u724c\u7535\u5b50\u4e66\u8be6\u60c5\u9875\u9646\u7eed\u53d1\u5e03<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u5f85\u66f4\u65b0<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>AI\u9a8c\u8bc1\u62a5\u544a<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5c06\u6bcf\u4e2a\u6848\u4f8b\u7684\u5173\u952e\u6570\u636e\uff08\u8282\u80fd\u7387\u3001COP\u503c\u3001\u8fd0\u884c\u8d39\u7528\uff09\u53d1\u9001\u7ed9\u4e3b\u6d41AI\u5de5\u5177\u9a8c\u8bc1\uff0c\u5c06\u9a8c\u8bc1\u7ed3\u679c\u4f5c\u4e3a\u989d\u5916\u4fe1\u4efb\u80cc\u4e66\u5217\u5165\u8fed\u4ee3\u65e5\u5fd7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">9.2 \u77e5\u8bc6\u5e93\u5f15\u7528\u7d22\u5f15<\/h3>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e00\u3001\u884c\u4e1a\u6807\u51c6\u4e0e\u89c4\u8303<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6587\u4ef6\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6db5\u76d6\u7ae0\u8282<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300aJGJ 142-2012 \u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c3\u30014\u30018\u7ae0\uff08\u7ba1\u5f84\u3001\u65bd\u5de5\u3001\u9a8c\u6536\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300aGB 50736 \u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c3\u30014\u7ae0\uff08\u70ed\u8d1f\u8377\u8ba1\u7b97\u3001\u6c34\u529b\u5e73\u8861\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300a2009JSCS-4 \u5168\u56fd\u6c11\u7528\u5efa\u7b51\u5de5\u7a0b\u8bbe\u8ba1\u6280\u672f\u63aa\u65bd-\u6696\u901a\u7a7a\u8c03-\u52a8\u529b\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c4\u7ae0\uff08\u6c34\u8d28\u8981\u6c42\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300a12K404 \u5730\u9762\u8f90\u5c04\u4f9b\u6696\u7cfb\u7edf\u5b89\u88c5\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c4\u7ae0\uff08\u65bd\u5de5\u5b89\u88c5\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>\u4e8c\u3001\u5916\u90e8\u8ba4\u8bc1\u4e0e\u62a5\u544a<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u8868\u683c<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6587\u4ef6\u540d\u79f0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6db5\u76d6\u7ae0\u8282<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u7eff\u7fbd1_\u73af\u4fdd\u767d\u6676\u677f.pdf\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c4\u7ae0\uff08\u8f85\u6750\u68c0\u6d4b\u62a5\u544a\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u4f1f\u661fXPS\u5730\u6696\u4fdd\u6e29\u677f\u7b2c\u4e09\u65b9\u68c0\u6d4b\u62a5\u544a.pdf\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c4\u7ae0\uff08\u8f85\u6750\u68c0\u6d4b\u62a5\u544a\uff09<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u300a\u4e2d\u56fd\u4e94\u6052\u884c\u4e1a\u53d1\u5c55\u767d\u76ae\u4e661.0\u7248\u300b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7b2c7\u7ae0\uff08\u672a\u6765\u8d8b\u52bf\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<style>\n.lmcase-wrap{background:#fafafa;border:1px solid #e6e6e6;border-radius:12px;padding:22px 20px;margin:26px 0;font-size:15px;line-height:1.8;}\n.lmcase-h{font-size:19px;font-weight:800;color:#1a1a1a;margin:0 0 6px;line-height:1.5;}\n.lmcase-d{font-size:14px;color:#666;margin:0 0 18px;line-height:1.7;}\n.lmcase-g{margin-bottom:16px;}\n.lmcase-t{font-size:15.5px;font-weight:700;color:#c0392b;margin-bottom:2px;line-height:1.5;}\n.lmcase-n{font-size:13.5px;color:#888;margin-bottom:8px;line-height:1.6;}\n.lmcase{display:block;background:#fff;border:1px solid #ececec;border-left:3px solid #c0392b;border-radius:7px;padding:9px 13px;margin:5px 0;color:#1a1a1a;text-decoration:none;font-size:14.5px;line-height:1.6;}\n.lmcase:hover{background:#fff6f2;border-left-color:#96281b;}\n@media(max-width:640px){.lmcase-wrap{padding:16px 13px;}.lmcase-h{font-size:17px;}.lmcase{font-size:14px;}}\n<\/style>\n\n<div class=\"lmcase-wrap\" data-page-node-id=\"Cy7HUzJgFic405FtbooLqt\">\n  <div class=\"lmcase-h\" data-page-node-id=\"PBVYKyRFDvowRPB5a7uuRi\">\u6210\u90fd\u771f\u5b9e\u5b8c\u5de5\u6848\u4f8b<\/div>\n  <div class=\"lmcase-d\" data-page-node-id=\"TUiAdHAuecIVNgnCya1Cbk\">\u4ee5\u4e0b\u5168\u90e8\u4e3a\u9f99\u8109\u6696\u901a\u6210\u90fd\u672c\u5730\u5df2\u4ea4\u4ed8\u5de5\u5730\uff0c\u70b9\u5f00\u53ef\u770b\u5b8c\u6574\u914d\u7f6e\u3001\u65bd\u5de5\u8fc7\u7a0b\u4e0e\u5b9e\u666f\u7167\u7247\u3002<\/div>\n    <div class=\"lmcase-g\" data-page-node-id=\"hKU0kue9m19vWTClCxwk4H\">\n      <div class=\"lmcase-t\" data-page-node-id=\"Q6Q8FJGUpAmrEaGQer2hiY\">\u83f2\u65af\u66fc\u5730\u6696<\/div>\n      <div class=\"lmcase-n\" data-page-node-id=\"o2wGsUjqYsdXAKCtpuGM4M\">\u51b7\u51dd\u7089 + \u8282\u80fd\u8054\u52a8<\/div>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=7644\" data-page-node-id=\"Z2q9M4MiQcRPzpxnldZeNw\">\u6210\u90fd\u5e78\u798f\u62fe\u51492\u671f\uff5c\u65e5\u7acb\u4e00\u62d6\u56db\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u51b7\u51dd\u5730\u6696\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11717\" data-page-node-id=\"F79qCIuuKOIb2j4zEwBKAV\">\u6210\u90fd\u6b66\u4faf\u533a\u5d11\u7389\u9526\u57ce88\u33a1\u5e73\u5c42\uff5c\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11797\" data-page-node-id=\"gb6kGlpiHiW5DD6EcEhXpW\">\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11817\" data-page-node-id=\"hcwdSPyOIsEU3erDYpskDV\">\u6210\u90fd\u53cc\u6d41\u533a\u5929\u5e9c\u58f9\u53f799\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u8282\u80fd\u8bbe\u8ba1+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11822\" data-page-node-id=\"mrvq1cGkFwCoVQ2xKxN2SY\">\u6210\u90fd\u6210\u534e\u533a\u878d\u521b\u7396\u534e\u53f0114\u33a1\u56db\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11977\" data-page-node-id=\"aEGMB3uqNsbNlRwW23kx2G\">\u6210\u90fd\u9f99\u6e56\u4e09\u5343\u4e91\u95263\u65e5\u7acb\u8212\u4eab\u4e00\u62d6\u4e94+\u83f2\u65af\u66fc\u5730\u6696\u6848\u4f8b<\/a>\n    <\/div>\n    <div class=\"lmcase-g\" data-page-node-id=\"A494IZjGVBALqjJ7NrHyoW\">\n      <div class=\"lmcase-t\" data-page-node-id=\"A6dGVODTvuEJ9sz37voNEQ\">\u535a\u4e16 \/ \u745e\u7f8e \/ \u66fc\u745e\u5fb7 \/ \u5c0f\u5361<\/div>\n      <div class=\"lmcase-n\" data-page-node-id=\"deRWFEWtiRvjEdUvRpHzsL\">\u4e0d\u540c\u70ed\u6e90\u9635\u8425\u7684\u771f\u5b9e\u80fd\u8017\u8868\u73b0<\/div>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=5180\" data-page-node-id=\"xH1qbD6k3OlkNWLCUKp8M3\">\u5929\u5e9c\u516c\u56ed\u672a\u6765\u57ce\u674e\u8001\u5e08-\u5c0f\u5361\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=6980\" data-page-node-id=\"NsAFw9sROzDjK7a07BDv9E\">\u6210\u90fd\u5e02\u65b0\u90fd\u533a\u4fdd\u5229\u6e56\u5fc3\u5c9b\uff5c\u65e5\u7acbVAM mini II\u4e2d\u592e\u7a7a\u8c03+\u745e\u7f8e\u53cc\u51b7\u51dd\u7089\u5730\u6696+\u72ec\u7acb\u65b0\u98ce+\u5168\u5c4b\u51c0\u6c34 \u5b8c\u5de5\u5b9e\u666f\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11626\" data-page-node-id=\"i5yMlYp4QY9zh9AprjWVzF\">\u6210\u90fd\u5929\u5e9c\u4e16\u5bb6\u4e8c\u671f\uff5c\u65e5\u7acb\u8212\u4eab160\u4e00\u62d6\u4e94\u4e2d\u592e\u7a7a\u8c03+\u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11630\" data-page-node-id=\"6AtTshjDxbiTmoWCMXX9Z4\">\u6210\u90fd\u5929\u6295\u6ee8\u6e56\u94c2\u8403\uff5c\u65e5\u7acb\u98ce\u7ba1\u673a+\u535a\u4e16\u51b7\u51dd\u7089\u5730\u6696+\u65b0\u98ce\u4e09\u7cfb\u7edf\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11820\" data-page-node-id=\"CVtz1wFYlAVEsDl2lzVDRM\">\u6210\u90fd\u9526\u6c5f\u533a\u5854\u5b50\u5c71\u58f9\u53f7\u5730\u6696\u6848\u4f8b\uff5c\u66fc\u745e\u5fb7\u51b7\u51dd\u7089+\u8282\u80fd\u8054\u52a8\uff0c135\u33a1\u91c7\u669620\u5e74\u66f4\u7701<\/a>\n    <\/div>\n    <div class=\"lmcase-g\" data-page-node-id=\"5e1A9KjEhEw6X5mpDMVNcy\">\n      <div class=\"lmcase-t\" data-page-node-id=\"SImFOiAl8tDp6PfpF7ASRP\">\u5927\u5e73\u5c42 \/ \u522b\u5885\u5730\u6696<\/div>\n      <div class=\"lmcase-n\" data-page-node-id=\"G1AMuvIuhErPoY73CBbFGv\">\u5927\u9762\u79ef\u7cfb\u7edf\u7684\u8bbe\u8ba1\u4e0e\u65bd\u5de5\u96be\u70b9<\/div>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=2511\" data-page-node-id=\"gHkvz2KuMT81Ou2CIlblw4\">\u6210\u90fd\u674e\u5973\u58eb\u00b7170\u33a1\u5927\u5e73\u5c42\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce+\u667a\u6167\u96c6\u63a7\u6863\u6848<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=7207\" data-page-node-id=\"OX8TrN0mqsqOIbU3uzwNDJ\">\u6210\u90fd\u534a\u5c9b\u57ce\u90a6\u5927\u5e73\u5c42260m\u00b2\u5730\u6696+\u53cc\u70ed\u6e90\u70ed\u6c34\u7cfb\u7edf\u5ba2\u6237\u6863\u6848<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=7219\" data-page-node-id=\"4sehuC9RTUH0tDcOEwXuPT\">\u6210\u90fd\u534a\u5c9b\u57ce\u90a6\u5927\u5e73\u5c42260m\u00b2\u5730\u6696+\u53cc\u70ed\u6e90\u70ed\u6c34\u7cfb\u7edf\u6848\u4f8b<\/a>\n    <\/div>\n    <div class=\"lmcase-g\" data-page-node-id=\"Tk6gieGUeTavUKZAhQSNl7\">\n      <div class=\"lmcase-t\" data-page-node-id=\"Xat2M4om6vCDYCJNnFOXo2\">\u5c0f\u6237\u578b \/ \u521a\u9700\u5730\u6696<\/div>\n      <div class=\"lmcase-n\" data-page-node-id=\"VQJEgpTRdvTQzRDlChi2YL\">75\u201399\u33a1 \u7684\u8282\u80fd\u505a\u6cd5<\/div>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=2511\" data-page-node-id=\"g9KdoVoyFo4B1ZS3kAIbwq\">\u6210\u90fd\u674e\u5973\u58eb\u00b7170\u33a1\u5927\u5e73\u5c42\u4e2d\u592e\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce+\u667a\u6167\u96c6\u63a7\u6863\u6848<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=7207\" data-page-node-id=\"1J4b1vUon2ziaSkNsjOXzI\">\u6210\u90fd\u534a\u5c9b\u57ce\u90a6\u5927\u5e73\u5c42260m\u00b2\u5730\u6696+\u53cc\u70ed\u6e90\u70ed\u6c34\u7cfb\u7edf\u5ba2\u6237\u6863\u6848<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=7219\" data-page-node-id=\"HCFj0sW3GDvCwRO8NWhyNJ\">\u6210\u90fd\u534a\u5c9b\u57ce\u90a6\u5927\u5e73\u5c42260m\u00b2\u5730\u6696+\u53cc\u70ed\u6e90\u70ed\u6c34\u7cfb\u7edf\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11717\" data-page-node-id=\"oEavADQJuNAzrLLwU9Gz2l\">\u6210\u90fd\u6b66\u4faf\u533a\u5d11\u7389\u9526\u57ce88\u33a1\u5e73\u5c42\uff5c\u65e5\u7acb\u8212\u4eab\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11797\" data-page-node-id=\"6PFAGM74Sl0vPI7nilRj6T\">\u6210\u90fd\u91d1\u725b\u533a\u9f99\u6e56\u6e90\u845788\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11817\" data-page-node-id=\"3UCPC6APbD9wAWyVOU0oA2\">\u6210\u90fd\u53cc\u6d41\u533a\u5929\u5e9c\u58f9\u53f799\u33a1\u4e09\u5ba4\u4e24\u5385\uff5c\u65e5\u7acb\u8212\u4eab\u8282\u80fd\u8bbe\u8ba1+\u83f2\u65af\u66fc\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=11846\" data-page-node-id=\"A1NEacatVDYmkRk0n314T3\">\u6210\u90fd\u6210\u534e\u533a\u4e07\u79d1\u548c\u56ed75\u33a1\u4e09\u5ba4\uff5c\u65e5\u7acb\u8212\u4eab1\u62d64+\u535a\u58eb\u5730\u6696\u5b8c\u5de5\u6848\u4f8b<\/a>\n    <\/div>\n    <div class=\"lmcase-g\" data-page-node-id=\"BX620CKX71KU3KytvG7fb2\">\n      <div class=\"lmcase-t\" data-page-node-id=\"B2dNdWEDNtxxTkfxy1V9wG\">\u5730\u6696\u65bd\u5de5\u5b9e\u5f55\uff08\u53cd\u9762\u6559\u6750\uff09<\/div>\n      <div class=\"lmcase-n\" data-page-node-id=\"0GBI5Qd96Q7POTg9orK6p4\">\u4fdd\u6e29\u6ca1\u505a\u597d\u7684\u771f\u5b9e\u540e\u679c<\/div>\n      <a class=\"lmcase\" href=\"https:\/\/longmai-nt.com\/?page_id=5092\" data-page-node-id=\"I2ftRVPqs4V0c0zRLThJlJ\">\u6210\u90fd\u909b\u5d03\u539f\u5885\u5730\u6696\u65bd\u5de5\u5b9e\u5f55\uff1a\u5e08\u5085\u6ca1\u505a\u4fdd\u6e29<\/a>\n    <\/div>\n<\/div>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udca1&nbsp;<strong>\u60f3\u4e86\u89e3\u6797\u5185\u3001\u745e\u7f8e\u3001\u83f2\u65af\u66fc\u7b49\u54c1\u724c\u7684\u5b8c\u6574\u4ea7\u54c1\u7ebf\u53c2\u6570\u548c\u5b89\u88c5\u6848\u4f8b\uff1f<\/strong>&nbsp;\u8bf7\u67e5\u770b\u6211\u4eec\u7684&nbsp;<strong>[\u54c1\u724c\u70ed\u6c34\u7cfb\u7edf\u4e13\u9898\u9875]<\/strong>&nbsp;\u2192 \u6bcf\u4e2a\u54c1\u724c\u90fd\u662f\u4e00\u672c\u72ec\u7acb\u7684\u7535\u5b50\u4e66\uff0c\u5305\u542b\u6280\u672f\u89e3\u6790\u3001\u5168\u4ea7\u54c1\u53c2\u6570\u548c\u771f\u5b9e\u5b89\u88c5\u6848\u4f8b\u3002<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u60f3\u4e86\u89e3\u9f99\u8109\u6696\u901a\u5176\u4ed6\u51b7\u6696\u8212\u9002\u65b9\u6848\uff1f<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1946\">\u65e5\u7acbVAM mini II \u5c0a\u777fmini\u4e8c\u4ee3\u8be6\u60c5\u9875<\/a>\u3011\u2192 \u9ad8\u6548\u8282\u80fd+\u6807\u914d\u51c0\u5316\uff0c\u65e0\u5730\u6696\u9700\u6c42\u9996\u9009<\/li>\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1811\">\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u2161 \u8be6\u60c5\u9875<\/a>\u3011\u2192 \u6e29\u6e7f\u53cc\u63a7\u65d7\u8230\uff0c\u6781\u81f4\u8212\u9002<\/li>\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1233\">\u65e5\u7acb\u6c34\u5885\u9002 \u8be6\u60c5\u9875<\/a>\u3011\u2192 \u5929\u6c34\u5730\u6c34\uff0c\u5927\u6237\u578b\/\u522b\u5885\u6781\u81f4\u8212\u9002<\/li>\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1824\">\u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5\u9875<\/a>\u3011\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=835\">\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5\u9875<\/a>\u3011\u2192 \u5fb7\u56fd\u51b7\u51dd\u7089\u6280\u672f\uff0c\u72ec\u7acb\u5730\u6696\u6696\u6c14\u7247\u65b9\u6848<\/li>\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1841\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5\u9875<\/a>\u3011\u2192 \u56fd\u4ea7\u6280\u672f\uff0c\u6ce8\u91cd\u63a7\u5236\u8d28\u91cf\uff0c\u4e3b\u6253\u6027\u4ef7\u6bd4\uff0c\u4e0e\u9f99\u8109\u6696\u901a\u5408\u4f5c\u5f00\u53d1<a href=\"https:\/\/longmai-nt.com\/?page_id=4499\">\u66fc\u745e\u5fb718KW\u53d8\u9891\u5c0f\u529f\u7387\u5355\u91c7\u6696<\/a>\u65b9\u6848\uff0c\u8282\u80fd\u7701\u94b1<\/li>\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1849\">\u5168\u5c4b\u51c0\u6c34\u7cfb\u7edf\u77e5\u8bc6\u805a\u5408\u9875<\/a>\u3011\u2192 \u4e94\u4ef6\u5957\u9009\u8d2d\u6307\u5357<\/li>\n\n<li>\u3010<a href=\"https:\/\/longmai-nt.com\/?page_id=1879\">\u5bb6\u7528\u70ed\u6c34\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a<\/a>\u3011\u2192\u70ed\u6c34\u8212\u9002\u7a33\u5b9a\u8282\u80fd\u9009\u8d2d\u6307\u5357<\/li>\n<\/ul>\n<\/blockquote>\n<\/blockquote>\n\n<div style=\"margin:32px 0;padding:22px 24px;border:1px solid #e3e3e3;border-left:4px solid #12314F;border-radius:10px;background:#fafbfc;\">\n  <h3 style=\"margin:0 0 12px;font-size:18px;color:#12314F;\">\u4ece\"\u770b\u61c2\u4e86\"\u5230\"\u80fd\u9a8c\u6536\"\uff1a\u300a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b<\/h3>\n  <p style=\"margin:0 0 12px;line-height:1.8;color:#333;\">\u8fd9\u4e00\u9875\u628a\u5730\u6696\u7684\u539f\u7406\u3001\u70ed\u6e90\u3001\u8f93\u914d\u3001\u672b\u7aef\u8bb2\u900f\u4e86\u3002\u4f46\u4e1a\u4e3b\u771f\u6b63\u5bb9\u6613\u5403\u4e8f\u7684\u5730\u65b9\u5728\u540e\u9762\uff1a\u76d8\u7ba1\u95f4\u8ddd\u6309 De16 \u8fd8\u662f De20 \u6392\u3001\u5355\u8def\u957f\u5ea6\u4e0a\u9650\u662f\u591a\u5c11\u3001\u5206\u96c6\u6c34\u5668\u51e0\u8def\u600e\u4e48\u5b9a\u3001\u6253\u538b\u591a\u5c11\u5146\u5e15\u4fdd\u591a\u4e45\u3001\u8c46\u77f3\u56de\u586b\u517b\u62a4\u51e0\u5929\u3002\u8fd9\u4e9b\u662f\u53ef\u91cf\u5316\u7684\u9a8c\u6536\u6807\u51c6\uff0c\u624b\u518c\u7b2c\u56db\u90e8\u5206\u548c\u9644\u5f55\u91cc\u9010\u6761\u7ed9\u4e86\u6570\uff0c\u53ef\u4ee5\u76f4\u63a5\u62ff\u53bb\u548c\u65bd\u5de5\u65b9\u5bf9\u3002<\/p>\n  <p style=\"margin:0;line-height:1.8;\"><a href=\"https:\/\/longmai-nt.com\/?page_id=669\" style=\"color:#12314F;font-weight:700;text-decoration:none;\">\u2192 \u6253\u5f00\u300a\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\u300b\uff088 \u4e2a\u90e8\u5206 \u00b7 59 \u5f20\u53c2\u6570\u8868\uff09<\/a><\/p>\n<\/div>\n\n<a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u767d\u76ae\u4e66 \uff1a\u591a\u8054\u673a\u539f\u7406\u3001\u9009\u578b\u3001\u5b89\u88c5\u9a8c\u6536\u4e0e\u552e\u540e\u5168\u89e3<\/a> \u2014\u2014 \u591a\u8054\u673a\u9009\u578b\u5b89\u88c5\u5168\u89e3\n<a href=\"https:\/\/longmai-nt.com\/?page_id=10970\">\u6210\u90fd\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u4ef7\u683c\u53c2\u8003<\/a> \u2014\u2014 \u5404\u7cfb\u5217\u6210\u4ea4\u533a\u95f4\n<a href=\"https:\/\/longmai-nt.com\/?page_id=4556\">\u5730\u6696\u62a5\u4ef7\u8ba1\u7b97\u5668<\/a>\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13579\">\u6c1f\u7cfb\u7edf\u65b9\u6848\u600e\u4e48\u8bbe\u8ba1\u9009\u578b<\/a> \u2014\u2014 \u4e2d\u592e\u7a7a\u8c03\u8bbe\u8ba1\u9009\u578b\u4e94\u6b65\u6cd5\n<a href=\"https:\/\/longmai-nt.com\/?page_id=13419\">\u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009<\/a> \u2014\u2014 \u6c1f\u673a\u6c34\u673a\u4e24\u8054\u4f9b\u4e00\u5f20\u8868\n\n<h2 class=\"wp-block-heading\">\u5e95\u90e8\uff1aCTA + \u670d\u52a1\u627f\u8bfa<\/h2>\n\n<p class=\"wp-block-paragraph\">\ud83c\udfaf&nbsp;<strong>\u73b0\u5728\u5c31\u884c\u52a8\uff0c\u62e5\u6709\u5c5e\u4e8e\u60a8\u7684\u8212\u9002\u5065\u5eb7\u91c7\u6696\uff01<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">\u670d\u52a1\u627f\u8bfa<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u514d\u8d39\u54a8\u8be2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8054\u7cfb\u6211\u4eec\uff0c\u5373\u53ef\u83b7\u5f971\u5bf91\u65b9\u6848\u8bbe\u8ba1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e13\u4e1a\u8bbe\u8ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u8c28\u6309\u70ed\u8d1f\u8377\u8ba1\u7b97\u9009\u578b\uff0c\u63d0\u4f9b1-2\u5957\u4f9b\u6696\u65b9\u6848<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7cbe\u5de5\u5b89\u88c5<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e25\u683c\u6267\u884c\u7cbe\u5de5\u516d\u6b65\u6cd5\uff0c\u9690\u853d\u5de5\u7a0b\u62cd\u7167\u5b58\u6863<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10\u5e74\u80fd\u6e90\u4fdd\u969c<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u52a0\u5165\u4f1a\u5458\u8ba1\u5212\uff0c\u9501\u5b9a\u672a\u676510\u5e74\u91c7\u6696\u80fd\u8017\uff0c\u8d85\u51fa\u90e8\u5206\u6211\u4eec\u627f\u62c5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u670d\u52a1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u957f\u671f\u7ef4\u62a4\u3001\u6bcf\u5e74\u4e00\u6b21\u514d\u8d39\u4f53\u68c0\u3001\u6545\u969c\u62a5\u4fee2\u5c0f\u65f6\u54cd\u5e94\u300124\u5c0f\u65f6\u5185\u4e0a\u95e8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\"><strong>\u5382\u5bb6\u8d1f\u8d23\u4ea7\u54c1\uff0c\u9f99\u8109\u8d1f\u8d23\u7ed3\u679c\u3002<\/strong>&nbsp;\u540c\u6837\u7684\u70ed\u6c34\u7cfb\u5217\uff0c\u4e0d\u540c\u5b89\u88c5\u5546\u88c5\u51fa\u6765\u7684\u6548\u679c\u548c\u80fd\u8017\u80fd\u5dee\uff1e30%\u3002\u6211\u4eec\u7684\u5dee\u5f02\u5316\u5728\u4e8e\uff1a\u7cfb\u7edf\u56db\u8981\u7d20\u8bbe\u8ba1\uff08\u70ed\u6e90-\u8f93\u914d-\u672b\u7aef-\u63a7\u5236\u5339\u914d\uff09\u3001\u91c7\u6696\u4e0e\u70ed\u6c34\u5206\u79bb\u8bbe\u8ba1\u3001\u5168\u53d8\u9891\u4e00\u6b21\u7cfb\u7edf\u3001\u4ee5\u53ca\u4f1a\u5458\u5236\u957f\u671f\u670d\u52a1\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\u642d\u914d<a href=\"https:\/\/longmai-nt.com\/?page_id=1758\">\u65e5\u7acb\u65b0\u98ce<\/a>+<a href=\"https:\/\/longmai-nt.com\/?page_id=916\">\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u7cfb\u7edf<\/a>\uff0c\u9f99\u8109\u6696\u901a\u4e3a\u4e24\u8054\u4f9b\u7528\u6237\u63d0\u4f9b<a href=\"https:\/\/longmai-nt.com\/?page_id=518\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/a>\uff0c\u4e3a\u7528\u6237\u63d0\u4f9b\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c\uff0c\u6253\u9020\u6301\u7eed\u6027\u8282\u80fd\u7a33\u5b9a\u7684\u8212\u9002\u5bb6\u3002<\/p>\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde&nbsp;<strong>\u6210\u90fd\u5357\u5bcc\u68ee\u70ed\u7ebf\uff1a<a href=\"tel:02886131795\">028-86131795<\/a><\/strong><br>\ud83d\udcde&nbsp;<strong>\u6210\u90fd\u5317\u5bcc\u68ee\u70ed\u7ebf\uff1a<a href=\"tel:02865272586\">028-65272586<\/a><\/strong><\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\">\ud83d\udcf1 <a href=\"tel:13008113409\">\u4f59\u6653\u73b2\uff1a130-0811-3409<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\">\ud83d\udcf1 <a href=\"tel:18100839248\">\u90ed\u7ecf\u7406\uff1a181-0083-9248<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\">\ud83d\udcf1 <a href=\"tel:15828489188\">\u9ec4\u7ecf\u7406\uff1a158-2848-9188<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n\n<p class=\"has-ast-global-color-2-color has-text-color has-link-color wp-elements-4 wp-block-paragraph\">\ud83d\udcf1 <a href=\"tel:13908183204\">\u4f59\u7231\u82f1\uff1a139-0818-3204<\/a> \u5fae\u4fe1\u540c\u53f7<\/p>\n\n<p class=\"wp-block-paragraph\">\u9f99\u8109\u6696\u901a\u00b7\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff1a <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892%7C30.598786%7C104.074284%7C30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\"><\/a><a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107&amp;geoobj=104.05892%7C30.598786%7C104.074284%7C30.605656&amp;query_type=IDQ&amp;query=%E6%97%A5%E7%AB%8B%E5%8F%98%E9%A2%91%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%97%97%E8%88%B0%E5%BA%97(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8D%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17\">\ud83d\udccd \u6210\u90fd\u5e02\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<\/a><br>\u9f99\u8109\u6696\u901a\u00b7\u5317\u5bcc\u68ee\u6210\u534e\u5e97\uff1a<a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108&amp;geoobj=104.059547%7C30.599807%7C104.07041%7C30.604665&amp;query_type=IDQ&amp;query=%E6%88%90%E9%83%BD%E6%97%A5%E7%AB%8B%E4%B8%AD%E5%A4%AE%E7%A9%BA%E8%B0%83%E6%99%BA%E6%85%A7%E7%A9%BA%E6%B0%94%E9%A6%86(%E9%BE%99%E8%84%89%E6%9A%96%E9%80%9A%E5%8C%97%E5%AF%8C%E6%A3%AE%E5%BA%97)&amp;zoom=17.5\">\ud83d\udccd \u6210\u90fd\u5e02\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7<\/a><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"1. \u6211\u8be5\u9009\u71c3\u6c14\u9505\u7089\u8fd8\u662f\u7a7a\u6c14\u80fd\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u8fd9\u53d6\u51b3\u4e8e\u60a8\u5bb6\u7684\u6c14\u6e90\u3001\u9762\u79ef\u548c\u957f\u671f\u5c45\u4f4f\u89c4\u5212\u3002\u6709\u5929\u7136\u6c14\u4e14\u8ffd\u6c42\u4f4e\u521d\u88c5\u3001\u9ad8\u8212\u9002\u5ea6\u7684\u5bb6\u5ead\u53ef\u9009\u9ad8\u6548\u51b7\u51dd\u7089\uff1b\u82e5\u8ffd\u6c42\u6781\u4f4e\u8fd0\u884c\u8d39\uff08\u6bd4\u71c3\u6c14\u770140-60%\uff09\u3001\u957f\u671f\u81ea\u4f4f\uff0c\u7a7a\u6c14\u80fd\u662f\u66f4\u4f18\u9009\u62e9\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"2. \u51b7\u51dd\u7089\u662f\u4e0d\u662f\u4e00\u5b9a\u6bd4\u666e\u901a\u7089\u597d\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e0d\u4e00\u5b9a\u3002 \u51b7\u51dd\u7089\u5fc5\u987b\u5728\u4f4e\u6e29\u7cfb\u7edf\uff08\u6c34\u6e29\u226455\u2103\uff09 \u4e0b\u624d\u80fd\u53d1\u6325\u5176\u70ed\u6548\u7387\u4f18\u52bf\u3002\u5982\u679c\u60a8\u5bb6\u914d\u5957\u7684\u662f\u4f20\u7edf\u6696\u6c14\u7247\uff08\u9ad8\u6e29\uff09\uff0c\u90a3\u4e48\u51b7\u51dd\u7089\u7684\u8282\u80fd\u4f18\u52bf\u65e0\u6cd5\u4f53\u73b0\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"3. \u5730\u6696\u76d8\u7ba1\u662f16\u7ba1\u597d\u8fd8\u662f20\u7ba1\u597d\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"20\u7ba1\uff08De20\uff09\u66f4\u4f18\uff0c\u4f46\u4ee3\u4ef7\u662f\u589e\u52a0\u6210\u672c\u3002 16\u7ba1\u65bd\u5de5\u65b9\u4fbf\uff0c\u9002\u7528\u4e8e100\u33a1\u4ee5\u4e0b\u5c0f\u6237\u578b\uff1b20\u7ba1\u7ba1\u5f84\u66f4\u5927\u3001\u5835\u7684\u98ce\u9669\u66f4\u5c0f\u3001\u6bcf\u56de\u8def\u53ef\u76d8\u66f4\u957f\u7684\u7ba1\uff0c\u66f4\u9002\u5408\u5927\u5e73\u5c42\u548c\u522b\u5885\u3002\u5e38\u88ab\u5ffd\u89c6\u7684\u4e00\u70b9\u662f\uff1a20\u7ba1\u7684\u201c\u5927\u6d41\u91cf\u3001\u5c0f\u6e29\u5dee\u201d\u53ef\u4ee5\u8ba9\u7cfb\u7edf\u66f4\u7a33\u5b9a\uff0c\u662f\u6bd4\u201c\u5bc6\u94fa\u201d\u66f4\u9ad8\u7ea7\u7684\u6280\u672f\u601d\u8def\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"4. \u4e3b\u7ba1\u7528De32\u8fd8\u662fDe25\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4f18\u5148\u7528De32\u3002 \u5f88\u591a\u7cfb\u7edf\u95ee\u9898\uff08\u5982\u672b\u7aef\u4e0d\u70ed\u3001\u9505\u7089\u566a\u97f3\u5927\uff09\u90fd\u6e90\u4e8e\u201c\u4e3b\u7ba1\u592a\u7ec6\uff0c\u8fd0\u529b\u4e0d\u8db3\u201d\u3002De32\u7684\u622a\u9762\u79ef\u662fDe25\u76841.6\u500d\uff0c\u6d41\u91cf\u63d0\u534760%\u4ee5\u4e0a\uff0c\u80fd\u663e\u8457\u6539\u5584\u6c34\u529b\u5e73\u8861\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"5. \u5730\u6696\u62a5\u4ef7\u4e3a\u4ec0\u4e48\u5dee\u5f02\u8fd9\u4e48\u5927\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u62a5\u4ef7\u5dee\u5f02\u4e3b\u8981\u4f53\u73b0\u5728\uff1a1. \u9505\u7089\u578b\u53f7\uff08\u51b7\u51dd\u7089>\u5e38\u89c4\u7089\uff092. \u8f85\u6750\u54c1\u724c\uff08\u767d\u6676\u677f\/\u5168\u94dd\u53cd\u5c04\u819c > \u666e\u901a\u6324\u5851\u677f\/\u9540\u94dd\u819c\uff093. \u63a7\u5236\u7cfb\u7edf\uff08\u8054\u52a8\u63a7\u5236\u5668 > \u65e0\u8054\u52a8\uff094. \u65bd\u5de5\u6807\u51c6\uff08\u6c2e\u6c14\u4fdd\u710a\u3001\u6253\u538b\u6d4b\u8bd5\u7b49\u5de5\u827a\uff0c\u597d\u7684\u65bd\u5de5\u65b9\u6210\u672c\u66f4\u9ad8\uff09\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"6. \u6211\u5bb6\u5c0f\u6237\u578b\uff0c\u5730\u6696\u4f1a\u4e0d\u4f1a\u5f88\u8d39\u6c14\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u53ea\u8981\u8bbe\u8ba1\u5f97\u5f53\uff08\u8d1f\u8377\u8ba1\u7b97\u51c6\u786e\u3001\u529f\u7387\u5339\u914d\u3001\u8054\u52a8\u63a7\u5236\uff09\uff0c\u5c0f\u6237\u578b\u7684\u5730\u6696\u8fd0\u884c\u8d39\u5b8c\u5168\u53ef\u63a7\u3002\u9891\u7e41\u542f\u505c\u624d\u662f\u8d39\u6c14\u7684\u5143\u51f6\uff0c\u8fd9\u4e0e\u6237\u578b\u5927\u5c0f\u65e0\u76f4\u63a5\u5173\u7cfb\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"7. \u58c1\u6302\u7089\u9891\u7e41\u542f\u505c\u600e\u4e48\u89e3\u51b3\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6838\u5fc3\u89e3\u51b3\u65b9\u6848\u662f\uff1a1. \u6362\u6210\u51b7\u51dd\u7089\uff08\u6700\u5c0f\u8f93\u51fa\u529f\u7387\u66f4\u4f4e\uff092. \u589e\u52a0\u5ba4\u6e29\u8054\u52a8\u63a7\u5236\uff08\u8ba9\u9505\u7089\u6536\u5230\u5ba4\u6e29\u8fbe\u6807\u4fe1\u53f7\u540e\u505c\u6b62\uff093. \u5927\u6d41\u91cf\u8bbe\u8ba1\uff08\u8ba9\u70ed\u91cf\u66f4\u5feb\u88ab\u8fd0\u8d70\uff0c\u5ef6\u957f\u71c3\u70e7\u65f6\u957f\uff09\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"8. \u5730\u6696\u76d8\u7ba1\u5730\u4e0a\u6709\u5f88\u591a\u7ba1\u5361\uff0c\u4f1a\u4e0d\u4f1a\u7834\u574f\u4fdd\u6e29\u5c42\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4f18\u8d28\u7684\u5730\u6696\u65bd\u5de5\u4f1a\u4f7f\u7528\u73af\u4fdd\u5361\u9489\uff0c\u5b83\u80fd\u7262\u7262\u56fa\u5b9a\u7ba1\u9053\uff0c\u540c\u65f6\u4e0d\u4f1a\u523a\u7a7f\u4fdd\u6e29\u677f\u5e95\u90e8\u7684\u805a\u82ef\u4e59\u70ef\u6ce1\u6cab\u5c42\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"9. \u5730\u6696\u56de\u586b\u5c42\u8981\u591a\u4e45\u624d\u80fd\u5e72\u900f\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6b63\u5e38\u517b\u62a4\u9700\u89817\u5929\uff08\u81ea\u7136\u517b\u62a4\uff09\uff0c\u671f\u95f4\u4e25\u7981\u8e29\u8e0f\u548c\u642c\u8fd0\u91cd\u7269\u30027\u5929\u540e\u53ef\u8fdb\u884c\u5730\u9762\u627e\u5e73\u65bd\u5de5\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"10. \u5730\u6696\u7cfb\u7edf\u80fd\u7528\u591a\u4e45\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5730\u6696\u76d8\u7ba1\uff08\u9690\u853d\u5de5\u7a0b\uff09\u5bff\u547d\u53ef\u8fbe50\u5e74\uff08\u963b\u6c27\u7ba1\u914d\u5408\u7cfb\u7edf\u7ef4\u62a4\uff09\u3002\u58c1\u6302\u7089\u5bff\u547d\u7ea610-15\u5e74\u3002\u7a7a\u6c14\u80fd\u4e3b\u673a\u8bbe\u8ba1\u5bff\u547d\u7ea620\u5e74\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"11. \u5730\u6696\u8981\u591a\u4e45\u6e05\u6d17\u4e00\u6b21\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6bcf2-3\u5e74\u6e05\u6d17\u4e00\u6b21\u5730\u6696\u7ba1\u3002\u5982\u679c\u53d1\u73b0\u7cfb\u7edf\u6c34\u5448\u9ed1\u8272\u6216\u94c1\u9508\u8272\uff0c\u9700\u7acb\u5373\u6e05\u6d17\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"12. \u6696\u6c14\u7247\u548c\u5730\u6696\u80fd\u6df7\u7528\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5b8c\u5168\u4e0d\u5efa\u8bae\u3002 \u56e0\u4e3a\u4e24\u8005\u5bf9\u6c34\u6e29\u8981\u6c42\u5b8c\u5168\u4e0d\u540c\u3002\u6df7\u5408\u4f7f\u7528\u4f1a\u5bfc\u81f4\u7cfb\u7edf\u6c34\u529b\u5931\u8861\uff0c\u6548\u679c\u5927\u6253\u6298\u6263\uff0c\u4e14\u589e\u52a0\u63a7\u5236\u96be\u5ea6\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"13. \u5730\u6696\u5206\u6c34\u5668\u88c5\u5728\u54ea\u91cc\u6700\u597d\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5206\u6c34\u5668\u5e94\u5b89\u88c5\u5728\u536b\u751f\u95f4\u3001\u53a8\u623f\u6216\u9633\u53f0\u7b49\u6709\u9632\u6c34\u8981\u6c42\u7684\u533a\u57df\u3002\u5207\u5fcc\u5c06\u5176\u5b89\u88c5\u5728\u5ba2\u5385\u6216\u5367\u5ba4\u5730\u9762\uff0c\u5426\u5219\u4e00\u65e6\u6f0f\u6c34\u4f1a\u9020\u6210\u91cd\u5927\u635f\u5931\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"14. \u4ec0\u4e48\u662f\u201c\u70ed\u6c34\u4e0e\u91c7\u6696\u5206\u79bb\u201d\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u8fd9\u662f\u4e00\u4e2a\u975e\u5e38\u4e13\u4e1a\u4e14\u5fc5\u8981\u7684\u8bbe\u8ba1\uff0c\u6307\u7528\u4e00\u4e2a\u72ec\u7acb\u7684\u70ed\u6c34\u5668\uff08\u71c3\u6c14\u6216\u7535\uff09\u4f9b\u5e94\u751f\u6d3b\u70ed\u6c34\uff0c\u800c\u5730\u6696\u58c1\u6302\u7089\u53ea\u8d1f\u8d23\u91c7\u6696\u3002\u8fd9\u6837\u505a\u5f7b\u5e95\u907f\u514d\u4e86\u201c\u5927\u9a6c\u62c9\u5c0f\u8f66\u201d\u548c\u201c\u590f\u5929\u8fc7\u70eb\u201d\u7684\u95ee\u9898\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"15. \u6211\u5bb6\u6709\u5730\u6696\uff0c\u4e0a\u9762\u80fd\u6446\u653e\u5927\u4ef6\u5bb6\u5177\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u53ef\u4ee5\uff0c\u4f46\u8981\u6ce8\u610f\uff1a1. \u65e0\u817f\u5bb6\u5177\uff08\u5982\u843d\u5730\u6c99\u53d1\uff09\u4e0b\u65b9\u4e0d\u5efa\u8bae\u94fa\u8bbe\u5730\u6696\u7ba1\uff0c\u4ee5\u9632\u70ed\u91cf\u6563\u4e0d\u51fa\u30022. \u6709\u817f\u5bb6\u5177\uff08\u5982\u5e8a\u3001\u8863\u67dc\uff09\u4e0b\u65b9\u53ef\u4ee5\u94fa\uff0c\u4f46\u8981\u786e\u4fdd\u5730\u9762\u6e29\u5ea6\u5747\u5300\uff0c\u4e0d\u5f71\u54cd\u6563\u70ed\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"16. \u5730\u6696\u9700\u8981\u548c\u4e2d\u592e\u7a7a\u8c03\u8054\u52a8\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u975e\u5e38\u63a8\u8350\u3002 \u5982\u679c\u5b89\u88c5\u4e86\u5929\u6c1f\u5730\u6c34\u6216\u5929\u6c34\u5730\u6c34\u7cfb\u7edf\uff0c\u53ef\u4ee5\u901a\u8fc7\u4e00\u4e2a11\u5bf8AI\u667a\u6167\u96c6\u63a7\u5c4f\u5b9e\u73b0\u5bf9\u7a7a\u8c03\u3001\u5730\u6696\u3001\u65b0\u98ce\u3001\u51c0\u5316\u7b49\u8bbe\u5907\u7684\u7edf\u4e00\u7ba1\u7406\u548c\u573a\u666f\u8054\u52a8\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"17. \u5730\u6696\u7cfb\u7edf\u9700\u8981\u5b9a\u671f\u4fdd\u517b\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u662f\u7684\uff0c\u9700\u8981\u3002 \u6bcf\u5e74\u4f9b\u70ed\u7ed3\u675f\u540e\uff0c\u5e94\u8fdb\u884c\u7b80\u5355\u7684\u7cfb\u7edf\u68c0\u67e5\uff1b\u6bcf2-3\u5e74\u5e94\u5bf9\u7ba1\u9053\u8fdb\u884c\u4e00\u6b21\u4e13\u4e1a\u6e05\u6d17\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"18. \u5730\u6696\u5730\u9762\u51fa\u73b0\u88c2\u7f1d\u600e\u4e48\u529e\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5982\u679c\u88c2\u7f1d\u975e\u5e38\u7ec6\u5c0f\uff08<0.5mm\uff09\uff0c\u901a\u5e38\u4e0d\u5f71\u54cd\u4f7f\u7528\uff0c\u53ea\u9700\u7528\u7f8e\u7f1d\u5242\u4fee\u8865\u5373\u53ef\u3002\u5982\u679c\u88c2\u7f1d\u8f83\u5927\u6216\u4f34\u6709\u7a7a\u6d1e\u58f0\uff0c\u9700\u8bf7\u4e13\u4e1a\u4eba\u5458\u68c0\u67e5\u56de\u586b\u5c42\u662f\u5426\u7a7a\u9f13\uff0c\u5e76\u53ca\u65f6\u4fee\u590d\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"19. \u5730\u6696\u94fa\u597d\u540e\uff0c\u4e0a\u9762\u8fd8\u80fd\u505a\u6728\u5730\u677f\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u53ef\u4ee5\u3002 \u5e94\u9009\u7528\u5730\u6696\u4e13\u7528\u5b9e\u6728\u590d\u5408\u5730\u677f\u6216\u5f3a\u5316\u590d\u5408\u5730\u677f\u3002\u9700\u6ce8\u610f\uff1a\u5730\u6696\u4f9b\u6c34\u6e29\u5ea6\u4e0d\u5b9c\u8d85\u8fc745\u2103\uff0c\u4e14\u6728\u5730\u677f\u5e94\u94fa\u8bbe\u4f38\u7f29\u7f1d\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"20. \u56fd\u4ea7\u9505\u7089\u548c\u8fdb\u53e3\u9505\u7089\u5dee\u522b\u5927\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6838\u5fc3\u5dee\u5f02\u5728\u4e8e\u63a7\u5236\u903b\u8f91\u548c\u957f\u671f\u7a33\u5b9a\u6027\u3002\u8fdb\u53e3\u54c1\u724c\uff08\u5982\u83f2\u65af\u66fc\u3001\u535a\u4e16\uff09\u5728\u71c3\u70e7\u63a7\u5236\u3001\u5b89\u5168\u4fdd\u62a4\u3001\u70ed\u4ea4\u6362\u6548\u7387\u7b49\u65b9\u9762\u6280\u672f\u79ef\u7d2f\u66f4\u6df1\u3002\u4f46\u56fd\u4ea7\u9505\u7089\uff08\u5982\u6d77\u5c14\u3001\u7f8e\u7684\uff09\u8fd1\u5e74\u5728\u6027\u4ef7\u6bd4\u548c\u672c\u5730\u5316\u670d\u52a1\u4e0a\u8fdb\u6b65\u5f88\u5feb\u3002\u5efa\u8bae\u4ed4\u7ec6\u7814\u8bfb\u4ea7\u54c1\u624b\u518c\u548c\u8bc4\u4ef7\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n\n<nav style=\"--separator: &quot;\/&quot;\" class=\"wp-block-breadcrumbs\" aria-label=\"\u9762\u5305\u5c51\"><ol><li><a href=\"https:\/\/longmai-nt.com\/\">\u9996\u9875<\/a><\/li><li><a href=\"https:\/\/longmai-nt.com\/?page_id=669\">\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a><\/li><li><span aria-current=\"page\">\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7<\/span><\/li><\/ol><\/nav>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"CollectionPage\",\n  \"name\":\"\u6210\u90fd\u5168\u5c4b\u5730\u6696\u5b8c\u5de5\u6848\u4f8b\u805a\u5408\u603b\u9875\",\n  \"description\":\"\u9f99\u8109\u6696\u901a\u6210\u90fd\u5730\u6696\u6848\u4f8b\u6c47\u603b\uff0c\u5305\u542b\u6697\u88c5\u9884\u57cb\u3001\u660e\u88c5\u6539\u9020\u3001\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\u5404\u5927\u677f\u5757\uff0c\u8986\u76d6\u9f99\u6cc9\u3001\u53cc\u6d41\u3001\u6b66\u4faf\u5404\u5927\u697c\u76d8\u5e73\u5c42\u3001\u522b\u5885\u6237\u578b\u5b9e\u666f\u65b9\u6848\uff0c\u652f\u6301\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\n  \"url\":\"https:\/\/longmai-nt.com\/?page_id=1976\",\n  \"dateModified\":\"2026-07-12\",\n  \"mainEntity\":{\n    \"@type\":\"ItemList\",\n    \"numberOfItems\":4,\n    \"itemListElement\":[\n      {\"@type\":\"WebPage\",\"name\":\"\u6697\u88c5\u9884\u57cb\u5730\u6696\u6848\u4f8b\u677f\u5757\",\"url\":\"#hidden-floorheat\"},\n      {\"@type\":\"WebPage\",\"name\":\"\u8001\u623f\u660e\u88c5\u5730\u6696\u6848\u4f8b\u677f\u5757\",\"url\":\"#surface-floorheat\"},\n      {\"@type\":\"WebPage\",\"name\":\"\u51b7\u51dd\u7089\u8282\u80fd\u5730\u6696\u677f\u5757\",\"url\":\"#condensing-boiler-heat\"},\n      {\"@type\":\"WebPage\",\"name\":\"\u65e7\u623f\u5730\u6696\u6539\u9020\u6848\u4f8b\u677f\u5757\",\"url\":\"#renovate-floorheat\"}\n    ]\n  },\n  \"publisher\":{\n    \"@type\":\"LocalBusiness\",\n    \"name\":\"\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n    \"telephone\":\"028-86131795\",\n    \"address\":{\"@type\":\"PostalAddress\",\"addressLocality\":\"\u6210\u90fd\u5e02\"}\n  }\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"FAQPage\",\n  \"mainEntity\":[\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u6210\u90fd\u65b0\u623f\u6697\u88c5\u5730\u6696\u9009\u4ec0\u4e48\u7ba1\u6750\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u6210\u90fd\u65b0\u623f\u540c\u6b65\u88c5\u4fee\u63a8\u8350\u4f1f\u661fPERT\u963b\u6c27\u76d8\u7ba1\uff0c\u4e3b\u7ba1\u91c7\u7528\u5927\u5f27\u5f2f\u5de5\u827a\u51cf\u5c11\u6c34\u963b\uff0c\u9002\u914d100-140\u33a1\u521a\u9700\u5e73\u5c42\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u8001\u623f\u4e0d\u7834\u574f\u5730\u9762\u53ef\u4ee5\u88c5\u5730\u6696\u5417\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u8001\u623f\u65e0\u6cd5\u9884\u57cb\u53ef\u9009\u62e9\u660e\u88c5\u6696\u6c14\u7247\u5730\u6696\uff0c\u65e0\u9700\u7838\u5730\u9762\uff0c1-2\u5929\u5b8c\u5de5\uff0c\u9002\u5408\u9f99\u6cc9\u3001\u53cc\u6d41\u8001\u65e7\u5c0f\u533a\u6539\u9020\u3002\"}\n    },\n    {\n      \"@type\":\"Question\",\n      \"name\":\"\u51b7\u51dd\u7089\u5730\u6696\u6bd4\u666e\u901a\u58c1\u6302\u7089\u7701\u6c14\u591a\u5c11\uff1f\",\n      \"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u66fc\u745e\u5fb7\u3001\u745e\u7f8e\u5206\u6bb5\u51b7\u51dd\u7089\u70ed\u6548\u7387\u66f4\u9ad8\uff0c\u957f\u671f\u4f7f\u7528\u76f8\u6bd4\u5e38\u89c4\u9505\u7089\u6bcf\u5e74\u53ef\u8282\u7ea620%-30%\u71c3\u6c14\u8d39\u7528\u3002\"}\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\":\"https:\/\/schema.org\",\n  \"@type\":\"BreadcrumbList\",\n  \"itemListElement\":[\n    {\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/longmai-nt.com\/\"},\n    {\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5730\u6696\u6848\u4f8b\u805a\u5408\u9875\",\"item\":\"https:\/\/longmai-nt.com\/?page_id=1976\"}\n  ]\n}\n<\/script>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u672c\u6587\u6863\u4e3a\u5730\u6696\u805a\u5408\u9875\u7684\u5b8c\u6574\u5185 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":669,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1976","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u5730\u6696\u7cfb\u7edf\u9009\u8d2d\u3001\u5b89\u88c5\u3001\u7ef4\u62a4\u4e00\u7ad9\u5f0f\u77e5\u8bc6\u5e93\u3002\u4ece\u70ed\u6e90(\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd)\u3001\u8f93\u914d(\u7ba1\u5f84\/\u6c34\u529b\u5e73\u8861)\u3001\u672b\u7aef(\u76d8\u7ba1\/\u56de\u586b)\u5230\u63a7\u5236(\u8054\u52a8\/\u6e29\u63a7)\uff0c\u6df1\u5ea6\u89e3\u6790\u8bef\u533a\u4e0e\u771f\u76f8\u3002\u9644\u771f\u5b9e\u6848\u4f8b\u300120\u5e74\u6210\u672c\u5bf9\u6bd4\u3001\u54c1\u724c\u9635\u8425\u4e0e\u9a8c\u6536\u6807\u51c6\u3002\u9f99\u8109\u6696\u901a\uff0c\u52a9\u4f60\u6253\u9020\u8212\u9002\u8282\u80fd\u5730\u6696\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=1976\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5730\u6696\u7cfb\u7edf\u9009\u8d2d\u3001\u5b89\u88c5\u3001\u7ef4\u62a4\u4e00\u7ad9\u5f0f\u77e5\u8bc6\u5e93\u3002\u4ece\u70ed\u6e90(\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd)\u3001\u8f93\u914d(\u7ba1\u5f84\/\u6c34\u529b\u5e73\u8861)\u3001\u672b\u7aef(\u76d8\u7ba1\/\u56de\u586b)\u5230\u63a7\u5236(\u8054\u52a8\/\u6e29\u63a7)\uff0c\u6df1\u5ea6\u89e3\u6790\u8bef\u533a\u4e0e\u771f\u76f8\u3002\u9644\u771f\u5b9e\u6848\u4f8b\u300120\u5e74\u6210\u672c\u5bf9\u6bd4\u3001\u54c1\u724c\u9635\u8425\u4e0e\u9a8c\u6536\u6807\u51c6\u3002\u9f99\u8109\u6696\u901a\uff0c\u52a9\u4f60\u6253\u9020\u8212\u9002\u8282\u80fd\u5730\u6696\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1976\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-26T15:37:36+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"17 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1976\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1976\",\"name\":\"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-01T18:22:46+00:00\",\"dateModified\":\"2026-10-26T15:37:36+00:00\",\"description\":\"\u5730\u6696\u7cfb\u7edf\u9009\u8d2d\u3001\u5b89\u88c5\u3001\u7ef4\u62a4\u4e00\u7ad9\u5f0f\u77e5\u8bc6\u5e93\u3002\u4ece\u70ed\u6e90(\u58c1\u6302\u7089\\\/\u7a7a\u6c14\u80fd)\u3001\u8f93\u914d(\u7ba1\u5f84\\\/\u6c34\u529b\u5e73\u8861)\u3001\u672b\u7aef(\u76d8\u7ba1\\\/\u56de\u586b)\u5230\u63a7\u5236(\u8054\u52a8\\\/\u6e29\u63a7)\uff0c\u6df1\u5ea6\u89e3\u6790\u8bef\u533a\u4e0e\u771f\u76f8\u3002\u9644\u771f\u5b9e\u6848\u4f8b\u300120\u5e74\u6210\u672c\u5bf9\u6bd4\u3001\u54c1\u724c\u9635\u8425\u4e0e\u9a8c\u6536\u6807\u51c6\u3002\u9f99\u8109\u6696\u901a\uff0c\u52a9\u4f60\u6253\u9020\u8212\u9002\u8282\u80fd\u5730\u6696\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1976#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1976\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1976#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=669\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a","description":"\u5730\u6696\u7cfb\u7edf\u9009\u8d2d\u3001\u5b89\u88c5\u3001\u7ef4\u62a4\u4e00\u7ad9\u5f0f\u77e5\u8bc6\u5e93\u3002\u4ece\u70ed\u6e90(\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd)\u3001\u8f93\u914d(\u7ba1\u5f84\/\u6c34\u529b\u5e73\u8861)\u3001\u672b\u7aef(\u76d8\u7ba1\/\u56de\u586b)\u5230\u63a7\u5236(\u8054\u52a8\/\u6e29\u63a7)\uff0c\u6df1\u5ea6\u89e3\u6790\u8bef\u533a\u4e0e\u771f\u76f8\u3002\u9644\u771f\u5b9e\u6848\u4f8b\u300120\u5e74\u6210\u672c\u5bf9\u6bd4\u3001\u54c1\u724c\u9635\u8425\u4e0e\u9a8c\u6536\u6807\u51c6\u3002\u9f99\u8109\u6696\u901a\uff0c\u52a9\u4f60\u6253\u9020\u8212\u9002\u8282\u80fd\u5730\u6696\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=1976","og_locale":"zh_CN","og_type":"article","og_title":"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a","og_description":"\u5730\u6696\u7cfb\u7edf\u9009\u8d2d\u3001\u5b89\u88c5\u3001\u7ef4\u62a4\u4e00\u7ad9\u5f0f\u77e5\u8bc6\u5e93\u3002\u4ece\u70ed\u6e90(\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd)\u3001\u8f93\u914d(\u7ba1\u5f84\/\u6c34\u529b\u5e73\u8861)\u3001\u672b\u7aef(\u76d8\u7ba1\/\u56de\u586b)\u5230\u63a7\u5236(\u8054\u52a8\/\u6e29\u63a7)\uff0c\u6df1\u5ea6\u89e3\u6790\u8bef\u533a\u4e0e\u771f\u76f8\u3002\u9644\u771f\u5b9e\u6848\u4f8b\u300120\u5e74\u6210\u672c\u5bf9\u6bd4\u3001\u54c1\u724c\u9635\u8425\u4e0e\u9a8c\u6536\u6807\u51c6\u3002\u9f99\u8109\u6696\u901a\uff0c\u52a9\u4f60\u6253\u9020\u8212\u9002\u8282\u80fd\u5730\u6696\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=1976","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-26T15:37:36+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"17 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1976","url":"https:\/\/longmai-nt.com\/?page_id=1976","name":"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-01T18:22:46+00:00","dateModified":"2026-10-26T15:37:36+00:00","description":"\u5730\u6696\u7cfb\u7edf\u9009\u8d2d\u3001\u5b89\u88c5\u3001\u7ef4\u62a4\u4e00\u7ad9\u5f0f\u77e5\u8bc6\u5e93\u3002\u4ece\u70ed\u6e90(\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd)\u3001\u8f93\u914d(\u7ba1\u5f84\/\u6c34\u529b\u5e73\u8861)\u3001\u672b\u7aef(\u76d8\u7ba1\/\u56de\u586b)\u5230\u63a7\u5236(\u8054\u52a8\/\u6e29\u63a7)\uff0c\u6df1\u5ea6\u89e3\u6790\u8bef\u533a\u4e0e\u771f\u76f8\u3002\u9644\u771f\u5b9e\u6848\u4f8b\u300120\u5e74\u6210\u672c\u5bf9\u6bd4\u3001\u54c1\u724c\u9635\u8425\u4e0e\u9a8c\u6536\u6807\u51c6\u3002\u9f99\u8109\u6696\u901a\uff0c\u52a9\u4f60\u6253\u9020\u8212\u9002\u8282\u80fd\u5730\u6696\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1976#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1976"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1976#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u58c1\u6302\u7089\u3001\u5730\u6696\u3001\u6696\u6c14\u7247\u3001\u70ed\u6c34\u7cfb\u7edf \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c","item":"https:\/\/longmai-nt.com\/?page_id=669"},{"@type":"ListItem","position":3,"name":"\u5730\u6696\u7cfb\u7edf \u00b7 \u805a\u5408\u9875\u77e5\u8bc6\u5e95\u5ea7"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1976","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1976"}],"version-history":[{"count":41,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1976\/revisions"}],"predecessor-version":[{"id":16642,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1976\/revisions\/16642"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/669"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}