{"id":1991,"date":"2026-06-02T13:29:44","date_gmt":"2026-06-02T05:29:44","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=1991"},"modified":"2026-10-23T10:44:38","modified_gmt":"2026-10-23T02:44:38","slug":"%e7%a5%a5%e5%9f%9f4-1-804%ef%bc%8c%e6%97%a5%e7%ab%8b%e6%b0%b4%e5%a2%85%e9%80%82160%e6%8b%96%e4%ba%94%e6%96%b9%e6%a1%88%e5%89%8d%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=1991","title":{"rendered":"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">\u7965\u57df4-1-804 \u00b7 \u6c6a\u8001\u5e08\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83c\udfe0 \u6210\u719f\u5c0f\u533a8\u697c \u00b7 \u5929\u6c34\u5730\u6c34\u5168\u5c4b\u8212\u9002\u7cfb\u7edf<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e5\u7acb\u6c34\u5885\u9002FX 160\u4e3b\u673a + 5\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1 + \u4f1f\u661f\u5730\u6696<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc64 \u5ba2\u6237\uff1a\u6c6a\u8001\u5e08\uff08\u9ad8\u77e5\u5bb6\u5ead\uff09\uff5c \ud83d\udcd0 \u7a7a\u8c03\u9762\u79ef\u7ea695\u33a1 \uff5c \ud83d\udc69\u200d\ud83d\udcbc \u987e\u95ee\uff1a\u90ed\u52c7\u79c0 \uff5c \ud83d\udcc5 \u5efa\u6863\uff1a2026\u5e743\u670818\u65e5<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udccb \u76ee\u5f55<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"#xmgk01\">\u9879\u76ee\u6982\u51b5<\/a><\/li>\n\n\n\n<li><a href=\"#xqzdyfafx02\">\u9700\u6c42\u8bca\u65ad\u4e0e\u65b9\u6848\u65b9\u5411<\/a><\/li>\n\n\n\n<li><a href=\"#faszxq03\">\u65b9\u6848\u914d\u7f6e\u8be6\u60c5<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#section-3-1\">\u5ba4\u5916\u4e3b\u673a<\/a><\/li>\n\n\n\n<li><a href=\"#section-3-2\">\u5ba4\u5185\u673a\u914d\u7f6e\uff085\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\uff09<\/a><\/li>\n\n\n\n<li><a href=\"#section-3-3\">\u5730\u6696\u7cfb\u7edf<\/a><\/li>\n\n\n\n<li><a href=\"#section-3-4\">\u53ef\u9009\u5347\u7ea7\u9879<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#zzyhbj04\">\u6700\u7ec8\u4f18\u60e0\u62a5\u4ef7<\/a><\/li>\n\n\n\n<li><a href=\"#jpdbfx05\">\u7ade\u54c1\u5bf9\u6bd4\u5206\u6790<\/a><\/li>\n\n\n\n<li><a href=\"#fahxys06\">\u65b9\u6848\u6838\u5fc3\u4f18\u52bf<\/a><\/li>\n\n\n\n<li><a href=\"#fwcn07\" type=\"internal\" id=\"#fwcn07\">\u670d\u52a1\u627f\u8bfa<\/a><\/li>\n\n\n\n<li><a href=\"#hyqy08\">\u4f1a\u5458\u6743\u76ca<\/a><\/li>\n\n\n\n<li><a href=\"#xckcdw09\">\u73b0\u573a\u52d8\u6d4b\u5b9a\u4f4d<\/a><\/li>\n\n\n\n<li><a href=\"#sjtz10\">\u8bbe\u8ba1\u56fe\u7eb8<\/a><\/li>\n\n\n\n<li><a href=\"#sgxczp11\">\u65bd\u5de5\u73b0\u573a\u7167\u7247<\/a><\/li>\n\n\n\n<li><a href=\"#dnsg12\">\u5730\u6696\u65bd\u5de5<\/a><\/li>\n\n\n\n<li><a href=\"#jlys13\">\u76d1\u7406\u9a8c\u6536<\/a><\/li>\n\n\n\n<li><a href=\"#shfwjl14\">\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/a><\/li>\n\n\n\n<li><a href=\"#section-15\">\u65b9\u6848\u987e\u95ee<\/a><\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"xmgk01\" class=\"wp-block-heading\">\u4e00\u3001\u9879\u76ee\u6982\u51b5<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><tr><td>\u4e1a\u4e3b<\/td><td>\u6c6a\u8001\u5e08<\/td><\/tr><tr><td>\u9879\u76ee\u5730\u5740<\/td><td>\u7965\u57df 4-1-804<\/td><\/tr><tr><td>\u6237\u578b\u7c7b\u578b<\/td><td>\u6210\u719f\u5c0f\u533a \u00b7 8\u697c<\/td><\/tr><tr><td>\u5c45\u4f4f\u60c5\u51b5<\/td><td>\u592b\u59bb\u4fe9 + \u513f\u5b50<\/td><\/tr><tr><td>\u7a7a\u8c03\u9762\u79ef<\/td><td>\u7ea695\u33a1<\/td><\/tr><tr><td>\u5730\u6696\u9762\u79ef<\/td><td>\u7ea695\u33a1<\/td><\/tr><tr><td>\u5185\u673a\u6570\u91cf<\/td><td>5\u53f0\uff08\u4e00\u62d6\u4e94\uff09<\/td><\/tr><tr><td>\u5bf9\u6bd4\u54c1\u724c<\/td><td>\u4e2d\u5e7f\u6b27\u65af\u7279\u3001\u7ea6\u514b\u3001\u53f2\u5bc6\u65af<\/td><\/tr><tr><td>\u65b9\u6848\u987e\u95ee<\/td><td>\u90ed\u52c7\u79c0\uff08\u9f99\u8109\u6696\u901a\uff09<\/td><\/tr><tr><td>\u8054\u7cfb\u7535\u8bdd<\/td><td>18100839248<\/td><\/tr><tr><td>\u5efa\u6863\u65e5\u671f<\/td><td>2026\u5e743\u670818\u65e5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83d\udd0d \u9879\u76ee\u7279\u70b9\u5206\u6790\uff1a<\/strong> \u6c6a\u8001\u5e08\u4e3a\u9ad8\u77e5\u5bb6\u5ead\uff0c\u5bf9\u8212\u9002\u5ea6\u3001\u5065\u5eb7\u3001\u8282\u80fd\u3001\u9759\u97f3\u5747\u6709\u8f83\u9ad8\u8981\u6c42\u3002\u5df2\u5bf9\u6bd4\u4e2d\u5e7f\u6b27\u65af\u7279\u3001\u7ea6\u514b\u3001\u53f2\u5bc6\u65af\u4e09\u5bb6\u5929\u6c34\u5730\u6c34\u54c1\u724c\uff0c\u5bf9\u6c34\u7cfb\u7edf\u6709\u4e00\u5b9a\u4e86\u89e3\u3002\u6838\u5fc3\u5173\u6ce8\u70b9\uff1a\u5185\u673a\u5916\u673a\u9759\u97f3\u3001\u957f\u671f\u8fd0\u884c\u8d39\u7528\u3001\u7a7a\u6c14\u8d28\u91cf\u51c0\u5316\u3002\u6700\u7ec8\u9009\u62e9\u65e5\u7acb\u6c34\u5885\u9002FX 160\u4e3b\u673a\uff0c\u96f6\u8d8a\u5185\u673a\u6700\u4f4e17dB\u8d85\u9759\u97f3\uff0c\u5168\u76f4\u6d41\u53d8\u9891\u957f\u671f\u7701\u7535\uff0c\u53ef\u9009PE\u51c0\u5316\u6a21\u5757\u9664\u83cc\u9664\u919b\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"xqzdyfafx02\" class=\"wp-block-heading\">\u4e8c\u3001\u9700\u6c42\u8bca\u65ad\u4e0e\u65b9\u6848\u65b9\u5411<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6838\u5fc3\u8bc9\u6c42<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u7edf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u5173\u6ce8\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65b9\u6848\u65b9\u5411<\/th><\/tr><tr><td>\u7cfb\u7edf\u7c7b\u578b<\/td><td>\u786e\u5b9a\u9009\u5929\u6c34\u5730\u6c34\uff08\u6c34\u7cfb\u7edf\u4e24\u8054\u4f9b\uff09<\/td><td>\u65e5\u7acb\u6c34\u5885\u9002FX \u00b7 \u5929\u6c34\u5730\u6c34\u4e00\u4f53<\/td><\/tr><tr><td>\u9759\u97f3<\/td><td>\u5bf9\u566a\u97f3\u654f\u611f\uff0c\u5916\u673a\u548c\u5185\u673a\u90fd\u8981\u5b89\u9759<\/td><td>\u96f6\u8d8a\u5185\u673a\u6700\u4f4e17dB\uff0c\u6bd4\u7ade\u54c1\u66f4\u5b89\u9759<\/td><\/tr><tr><td>\u8282\u80fd<\/td><td>\u957f\u671f\u8fd0\u884c\u8d39\u7528\u8981\u4f4e<\/td><td>\u5168\u76f4\u6d41\u53d8\u9891\uff0cIPLV\u9ad8\uff0c\u7a7a\u6c14\u80fd\u5730\u6696\u6bd4\u71c3\u6c14\u770140%+<\/td><\/tr><tr><td>\u7a7a\u6c14\u51c0\u5316<\/td><td>\u5bf9\u7a7a\u6c14\u8d28\u91cf\u6709\u8981\u6c42\uff0c\u9700\u8981\u51c0\u5316\u529f\u80fd<\/td><td>\u4e3b\u5367\u548c\u513f\u7ae5\u623f\u9009\u914dPE\u51c0\u5316\u6a21\u5757\uff0c\u9664\u83cc\u9664\u919b<\/td><\/tr><tr><td>\u4e3b\u673a\u89c4\u683c<\/td><td>140\u6216160\uff08\u6839\u636e\u5b9e\u9645\u8ba1\u7b97\u786e\u5b9a\uff09<\/td><td>\u63a8\u8350160\u578b\uff0c\u591a\u82b12-3\u5343\u6362\u6765\u66f4\u4ece\u5bb9\u5236\u51b7\u80fd\u529b<\/td><\/tr><tr><td>\u5ba2\u5385<\/td><td>51\u33a1\u5927\u7a7a\u95f4\uff0c\u62c5\u5fc3\u6548\u679c\u4e0d\u5747\u5300<\/td><td>\u53cc\u98ce\u76d8\uff08RFP-119+68\uff09\uff0c\u6c14\u6d41\u5747\u5300\u8986\u76d6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u9700\u6c42-\u62c5\u5fc3-\u75db\u70b9\u4e09\u7ef4\u8bca\u65ad<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7ef4\u5ea6<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5177\u4f53\u8868\u73b0<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u91cd<\/th><\/tr><tr><td>\u75db\u70b9<\/td><td>\u5bf9\u566a\u97f3\u654f\u611f\uff0c\u5f71\u54cd\u7761\u7720\u8d28\u91cf<\/td><td>\u2605\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u75db\u70b9<\/td><td>\u957f\u671f\u8fd0\u884c\u8d39\u7528\u4e0d\u53ef\u63a7<\/td><td>\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u62c5\u5fc3<\/td><td>\u5ba2\u538551\u33a1\u5927\u7a7a\u95f4\u6548\u679c\u4e0d\u5747\u5300<\/td><td>\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u62c5\u5fc3<\/td><td>\u4e3b\u673a\u9009140\u8fd8\u662f160\uff0c\u6015\u9009\u5c0f\u4e86<\/td><td>\u2605\u2605\u2605<\/td><\/tr><tr><td>\u9700\u6c42<\/td><td>\u7a7a\u6c14\u51c0\u5316\uff0c\u5b69\u5b50\u623f\u95f4\u5065\u5eb7\u4f18\u5148<\/td><td>\u2605\u2605\u2605\u2605<\/td><\/tr><tr><td>\u9700\u6c42<\/td><td>\u5168\u5c4b\u8212\u9002\u91c7\u6696\uff0c\u8d39\u7528\u53ef\u63a7<\/td><td>\u2605\u2605\u2605\u2605\u2605<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\ud83c\udfc6 \u6838\u5fc3\u8bbe\u8ba1\u903b\u8f91\uff1a<\/strong> \u6c6a\u8001\u5e08\u5df2\u5bf9\u6bd4\u4e09\u5bb6\u6c34\u7cfb\u7edf\u54c1\u724c\uff0c\u8bf4\u660e\u5bf9\u5929\u6c34\u5730\u6c34\u6709\u8ba4\u77e5\u57fa\u7840\u3002\u6838\u5fc3\u5dee\u5f02\u5316\u5728\u4e8e<strong>\u9759\u97f3<\/strong>\uff08\u96f6\u8d8a\u5185\u673a17dB vs \u7ade\u54c1\u66f4\u9ad8\uff09\u3001<strong>\u51c0\u5316<\/strong>\uff08PE\u6a21\u5757\u53ef\u9009\u914d\uff09\u3001<strong>\u5168\u53d8\u9891<\/strong>\uff08\u538b\u7f29\u673a+\u6c34\u6cf5+\u98ce\u673a\u5168\u53d8\u9891\uff0c\u65e0\u9700\u6c34\u7bb1\uff09\u3002\u4e3b\u673a\u4ece140\u5347\u7ea7\u5230160\uff0c\u591a\u82b12-3\u5343\u6362\u6765\u66f4\u4ece\u5bb9\u7684\u5236\u51b7\u4f59\u91cf\uff0c\u5168\u5f00\u4e0d\u62a2\u98ce\u91cf\u3002\u5ba2\u538551\u33a1\u7528\u53cc\u98ce\u76d8\u8986\u76d6\uff0c\u6c14\u6d41\u5747\u5300\u3002\u6700\u7ec8\u5ba2\u6237\u9009\u62e9160\u4e3b\u673a\u65b9\u6848\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"faszxq03\" class=\"wp-block-heading\">\u4e09\u3001\u65b9\u6848\u914d\u7f6e\u8be6\u60c5<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">3.1 \u5ba4\u5916\u4e3b\u673a<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7cfb\u5217<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5236\u51b7\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5236\u70ed\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6e29\u80fd\u529b<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u566a\u97f3<\/th><\/tr><tr><td>\u65e5\u7acb\u6c34\u5885\u9002FX<\/td><td>RAS-160FPUEN2Q\/M<\/td><td>14.0 kW<\/td><td>15.5 kW<\/td><td>-30\u2103\u7a33\u5b9a\u5236\u70ed\uff08\u8865\u6c14\u589e\u7113\uff09<\/td><td>57 dB(A)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u538b\u7f29\u673a\uff1a\u65e5\u7acb\u539f\u88c5\u53cc\u8f6c\u5b50\u53d8\u9891 \uff5c \u7535\u6e90\uff1a\u5355\u76f8\u7535<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.2 \u5ba4\u5185\u673a\u914d\u7f6e\uff085\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u533a\u57df<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u9762\u79ef<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><tr><td>\u5ba2\u9910\u5385+\u53a8\u623f<\/td><td>51.1\u33a1<\/td><td>RFP-119WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>\u5927\u7a7a\u95f4\u4e3b\u673a\uff0c\u8986\u76d6\u5ba2\u9910\u5385\u6838\u5fc3\u533a<\/td><\/tr><tr><td>\u5ba2\u9910\u5385+\u53a8\u623f<\/td><td>\u540c\u533a<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>\u526f\u673a\uff0c\u53cc\u98ce\u76d8\u6c14\u6d41\u5747\u5300<\/td><\/tr><tr><td>\u4e3b\u5367<\/td><td>19.4\u33a1<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>\u592b\u59bb\u4e3b\u5367\uff0c\u9759\u97f3\u4f18\u5148<\/td><\/tr><tr><td>\u513f\u5b50\u623f<\/td><td>18.4\u33a1<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>\u5b69\u5b50\u623f\u95f4\uff0c\u9759\u97f3+\u51c0\u5316<\/td><\/tr><tr><td>\u6b21\u5367<\/td><td>7\u33a1<\/td><td>RFP-34WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>\u5c0f\u623f\u95f4\uff0c\u591f\u7528\u5373\u53ef<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5408\u8ba1<\/strong>\uff1a5\u53f0\u96f6\u8d8a\u98ce\u673a\u76d8\u7ba1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5185\u673a\u7279\u70b9<\/strong>\uff1a\u539a\u5ea619.2cm \uff5c \u98ce\u901f6\u6863\uff08\u542b\u5fae\u98ce\uff09\uff5c \u6700\u4f4e17dB\u8d85\u9759\u97f3 \uff5c \u53ef\u9009PE\u51c0\u5316\u6a21\u5757\uff08+400\u5143\/\u4e2a\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8d85\u914d\u7387<\/strong>\uff1a\u6c34\u7cfb\u7edf\u5141\u8bb8\u2264200%\uff0c\u914d\u7f6e\u5408\u7406 \u2705<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.3 \u5730\u6696\u7cfb\u7edf<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u53c2\u6570<\/th><\/tr><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>95\u33a1<\/td><\/tr><tr><td>\u70ed\u6e90<\/td><td>\u6c34\u5885\u9002\u4e3b\u673a\uff08\u7a7a\u6c14\u80fd\u70ed\u6cf5\uff0c-30\u2103\u7a33\u5b9a\u5236\u70ed\uff09<\/td><\/tr><tr><td>\u4f9b\u6c34\u6e29\u5ea6<\/td><td>35-45\u2103\uff08\u6bd4\u71c3\u6c14\u770140%+\uff09<\/td><\/tr><tr><td>\u5730\u6696\u7ba1<\/td><td>PERT\u7ba1\uff08\u4f1f\u661f\uff09<\/td><\/tr><tr><td>\u5206\u96c6\u6c34\u5668<\/td><td>6\u8def\uff08\u5ba2\u9910\u53853\u8def + \u5367\u5ba43\u8def\uff09<\/td><\/tr><tr><td>\u4fdd\u6e29\u6750\u6599<\/td><td>\u4f1f\u661f\uff08\u73af\u4fdd\u65e0\u5473\uff09<\/td><\/tr><tr><td>\u63a7\u5236\u7cfb\u7edf<\/td><td>\u5206\u5ba4\u63a7\u6e29 + \u4e3b\u673a\u8054\u52a8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.4 \u53ef\u9009\u5347\u7ea7\u9879<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4ef7\u683c<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><tr><td>PE\u51c0\u5316\u6a21\u5757<\/td><td>400\u5143\/\u4e2a<\/td><td>\u4e3b\u5367\u548c\u513f\u7ae5\u623f\u9009\u914d\uff0c\u9664\u83cc\u9664\u919b<\/td><\/tr><tr><td>\u7f13\u51b2\u6c34\u7bb1<\/td><td>+2,600\u5143<\/td><td>\u63d0\u5347\u7cfb\u7edf\u7a33\u5b9a\u6027\uff0c\u51cf\u5c11\u4e3b\u673a\u9891\u7e41\u542f\u505c<\/td><\/tr><tr><td>\u4e94\u6052\u7cfb\u7edf\uff08\u9664\u6e7f\u65b0\u98ce\uff09<\/td><td>\u5f85\u5b9a<\/td><td>\u5168\u5c4b\u6052\u6e29\u6052\u6e7f\u6052\u6c27\uff0c\u5347\u7ea7\u8212\u9002\u4f53\u9a8c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"zzyhbj04\" class=\"wp-block-heading\">\u56db\u3001\u6700\u7ec8\u4f18\u60e0\u62a5\u4ef7<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">4.1 \u8bbe\u5907\u8d39\u7528<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u578b\u53f7\/\u8bf4\u660e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><tr><td>\u5ba4\u5916\u4e3b\u673a<\/td><td>\u6c34\u5885\u9002FX 160\u578b<\/td><td>1\u53f0<\/td><td>24,830\u5143<\/td><td>24,830\u5143<\/td><\/tr><tr><td>\u5185\u673a<\/td><td>RFP-119WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>3,500\u5143<\/td><td>3,500\u5143<\/td><\/tr><tr><td>\u5185\u673a<\/td><td>RFP-68WAR\/DBT\/P<\/td><td>3\u53f0<\/td><td>2,800\u5143<\/td><td>8,400\u5143<\/td><\/tr><tr><td>\u5185\u673a<\/td><td>RFP-34WAR\/DBT\/P<\/td><td>1\u53f0<\/td><td>2,625\u5143<\/td><td>2,625\u5143<\/td><\/tr><tr><td>\u5730\u6696\u7cfb\u7edf<\/td><td>\u76d8\u7ba1+\u4fdd\u6e29+\u56de\u586b\uff0895.8\u33a1\uff09<\/td><td>95.8\u33a1<\/td><td>169\u5143\/\u33a1<\/td><td>16,190\u5143<\/td><\/tr><tr><td colspan=\"4\">\u8bbe\u5907\u5c0f\u8ba1<\/td><td>55,545\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.2 \u5b89\u88c5\u8d39\u7528<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u6570\u91cf<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5355\u4ef7<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u8ba1<\/th><\/tr><tr><td>\u5185\u673a\u5b89\u88c5<\/td><td>\u542b\u94dc\u7ba1\u3001\u4fdd\u6e29\u7b49<\/td><td>5\u53f0<\/td><td>3,800\u5143<\/td><td>19,000\u5143<\/td><\/tr><tr><td>\u5916\u673a\u5b89\u88c5<\/td><td>\u4e3b\u673a\u3001\u652f\u67b6\u3001\u57fa\u7840<\/td><td>1\u53f0<\/td><td>3,600\u5143<\/td><td>3,600\u5143<\/td><\/tr><tr><td>\u4e3b\u673a\u7ebf\u63a7\u5668<\/td><td>\u2014<\/td><td>1\u4e2a<\/td><td>300\u5143<\/td><td>300\u5143<\/td><\/tr><tr><td>WiFi\u7ebf\u63a7\u5668<\/td><td>\u2014<\/td><td>4\u4e2a<\/td><td>200\u5143<\/td><td>800\u5143<\/td><\/tr><tr><td colspan=\"4\">\u5b89\u88c5\u5c0f\u8ba1<\/td><td>23,700\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.3 \u65b9\u6848\u603b\u4ef7<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u8bbe\u5907+\u5b89\u88c5\u5408\u8ba1<\/td><td class=\"has-text-align-right\" data-align=\"right\">79,245\u5143<\/td><\/tr><tr><td>\u6700\u7ec8\u4f18\u60e0\u4ef7\uff08\u542b\u8865\u8d34\/\u6d3b\u52a8\uff09<\/td><td class=\"has-text-align-right\" data-align=\"right\">71,341\u5143<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcb0 <strong>\u540c\u7cfb\u5217\u673a\u578b\u4e0e\u9884\u7b97\uff1a<\/strong><a href=\"https:\/\/longmai-nt.com\/?page_id=14764\">\u65e5\u7acb\u6c34\u5885\u9002 FX \/ VF \u5168\u7cfb\u5217\u673a\u578b\u4e0e\u6210\u5957\u9884\u7b97 \u2192<\/a>\uff08\u672c\u9875 160 \u540c\u7cfb\u5217\uff0c\u542b 140 \/ 160 \u9009\u578b\u5dee\u4ef7\u53c2\u8003\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 \u5305\u542b\u6807\u51c6\u5b89\u88c5\u5168\u90e8\u6750\u6599\uff0c\u65e0\u9690\u85cf\u589e\u9879\u3000\u3000\u274c \u4e0d\u542bPE\u51c0\u5316\u6a21\u5757\uff08\u53ef\u9009400\u5143\/\u4e2a\uff09<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"jpdbfx05\" class=\"wp-block-heading\">\u4e94\u3001\u7ade\u54c1\u5bf9\u6bd4\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c6a\u8001\u5e08\u5df2\u5bf9\u6bd4\u4e2d\u5e7f\u6b27\u65af\u7279\u3001\u7ea6\u514b\u3001\u53f2\u5bc6\u65af\u4e09\u5bb6\u5929\u6c34\u5730\u6c34\u54c1\u724c\uff0c\u4ee5\u4e0b\u4e3a\u65e5\u7acb\u6c34\u5885\u9002\u7684\u5dee\u5f02\u5316\u4f18\u52bf\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u5bf9\u6bd4\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u4e2d\u5e7f\u6b27\u65af\u7279 \/ \u7ea6\u514b \/ \u53f2\u5bc6\u65af<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65e5\u7acb\u6c34\u5885\u9002<\/th><\/tr><tr><td>\u9759\u97f3<\/td><td>\u4e00\u822c22-28dB<\/td><td>\u96f6\u8d8a\u5185\u673a\u6700\u4f4e17dB<\/td><\/tr><tr><td>\u53d8\u9891\u6280\u672f<\/td><td>\u90e8\u5206\u53d8\u9891\u6216\u9700\u914d\u6c34\u7bb1<\/td><td>\u5168\u53d8\u9891\uff08\u538b\u7f29\u673a+\u6c34\u6cf5+\u98ce\u673a\uff09\uff0c\u65e0\u9700\u6c34\u7bb1<\/td><\/tr><tr><td>\u51c0\u5316<\/td><td>\u4e00\u822c\u65e0\u9009\u914d<\/td><td>\u53ef\u9009PE\u51c0\u5316\u6a21\u5757\uff0c\u9664\u83cc\u9664\u919b<\/td><\/tr><tr><td>\u8d28\u4fdd<\/td><td>\u4e00\u822c3-5\u5e74<\/td><td>\u5165\u4f1a\u540e\u6574\u673a\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u8282\u80fd<\/td><td>IPLV\u4e00\u822c<\/td><td>\u5168\u76f4\u6d41\u53d8\u9891\uff0cIPLV\u9ad8\uff0c\u957f\u671f\u7701\u7535<\/td><\/tr><tr><td>\u5b89\u88c5\u8d44\u8d28<\/td><td>\u2014<\/td><td>\u65e5\u7acb\u94bb\u77f3\u5b89\u88c5\u5546\uff082025\u5e74\u5ea6\u6700\u9ad8\u8d44\u8d28\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1 \u6c6a\u8001\u5e08\u5bf9\u5929\u6c34\u5730\u6c34\u5df2\u6709\u4e86\u89e3\uff0c\u65b9\u6848\u91cd\u70b9\u4f53\u73b0\u65e5\u7acb\u5728\u9759\u97f3\u3001\u5168\u53d8\u9891\u3001\u51c0\u5316\u3001\u8d28\u4fdd\u56db\u4e2a\u7ef4\u5ea6\u7684\u5dee\u5f02\u5316\u4f18\u52bf\u3002<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"fahxys06\" class=\"wp-block-heading\">\u516d\u3001\u65b9\u6848\u6838\u5fc3\u4f18\u52bf<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u7279\u70b9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u8bf4\u660e<\/th><\/tr><tr><td>\u51fa\u98ce\u67d4\u548c<\/td><td>\u6c34\u7cfb\u7edf\u51fa\u98ce15-20\u2103\uff0c\u50cf\u81ea\u7136\u98ce\uff0c\u65e0\u5439\u98ce\u611f\uff0c\u4e0d\u5e72\u71e5\u4e0d\u5934\u75bc<\/td><\/tr><tr><td>\u8d85\u9759\u97f3<\/td><td>\u96f6\u8d8a\u5185\u673a\u6700\u4f4e17dB\uff0c\u6bd4\u7ade\u54c1\u5b89\u9759\uff0c\u4fdd\u969c\u7761\u7720\u8d28\u91cf<\/td><\/tr><tr><td>\u5168\u53d8\u9891\u8282\u80fd<\/td><td>\u538b\u7f29\u673a+\u6c34\u6cf5+\u98ce\u673a\u5168\u53d8\u9891\uff0c\u65e0\u9700\u6c34\u7bb1\uff0cIPLV\u9ad8\uff0c\u957f\u671f\u7701\u7535<\/td><\/tr><tr><td>\u5730\u6696\u8282\u80fd<\/td><td>\u7a7a\u6c14\u80fd\u6bd4\u71c3\u6c14\u770140%+\uff0c-30\u2103\u7a33\u5b9a\u5236\u70ed\uff08\u8865\u6c14\u589e\u7113\uff09<\/td><\/tr><tr><td>\u5ba2\u5385\u53cc\u98ce\u76d8<\/td><td>51\u33a1\u5927\u7a7a\u95f4\u53cc\u673a\u8986\u76d6\uff0c\u6c14\u6d41\u5747\u5300\u65e0\u6b7b\u89d2<\/td><\/tr><tr><td>\u51c0\u5316\u53ef\u9009<\/td><td>PE\u51c0\u5316\u6a21\u5757\u9664\u83cc\u9664\u919b\uff0c\u5b69\u5b50\u623f\u95f4\u5065\u5eb7\u4f18\u5148<\/td><\/tr><tr><td>\u5206\u5ba4\u63a7\u6e29<\/td><td>WiFi\u7ebf\u63a7\u5668\uff0c\u6bcf\u4e2a\u623f\u95f4\u72ec\u7acb\u63a7\u6e29\uff0c\u624b\u673a\u8fdc\u7a0b\u64cd\u4f5c<\/td><\/tr><tr><td>\u4ef7\u683c\u900f\u660e<\/td><td>\u8bbe\u5907+\u5b89\u88c5\u660e\u7ec6\u6e05\u6670\uff0c\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"fwcn07\" class=\"wp-block-heading\">\u4e03\u3001\u670d\u52a1\u627f\u8bfa<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u627f\u8bfa\u9879<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><tr><td>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/td><td>48\u5c0f\u65f6\u5185\u54cd\u5e94<\/td><\/tr><tr><td>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/td><td>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/td><\/tr><tr><td>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/td><td>\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6 \u00b7 \u94bb\u77f3\u5b89\u88c5\u5546<\/td><\/tr><tr><td>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/td><td>\u65e0\u9690\u85cf\u589e\u9879<\/td><\/tr><tr><td>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/td><td>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/td><\/tr><tr><td>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/td><td>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"hyqy08\" class=\"wp-block-heading\">\u516b\u3001\u4f1a\u5458\u6743\u76ca<\/h2>\n\n\n\n<figure id=\"hyqy08\" class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6743\u76ca<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9<\/th><\/tr><tr><td>\u8bbe\u5907\u5ef6\u4fdd<\/td><td>\u4e3b\u673a\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr><tr><td>\u7ba1\u9053\u8d28\u4fdd<\/td><td>\u4f1f\u661f\u7ba1\u905350\u5e74\u8d28\u4fdd<\/td><\/tr><tr><td>\u5b89\u88c5\u5de5\u7a0b\u8d28\u4fdd<\/td><td>2\u5e74\uff08\u4f1a\u5458\u5ef6\u81f35\u5e74\uff09<\/td><\/tr><tr><td>\u670d\u52a1\u6298\u6263<\/td><td>5-8\u6298<\/td><\/tr><tr><td>\u4f18\u5148\u54cd\u5e94<\/td><td>\u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/td><\/tr><tr><td>\u7cfb\u7edf\u5f02\u5e38\u514d\u8d39\u4e0a\u95e8<\/td><td>\u4e0d\u9650\u6b21\u6570<\/td><\/tr><tr><td>\u7ef4\u4fdd\u63d0\u9192<\/td><td>\u6ee4\u82af\u66f4\u6362\u3001\u6e05\u6d17\u4e3b\u52a8\u63d0\u9192<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"xckcdw09\" class=\"wp-block-heading\">\u4e5d\u3001\u73b0\u573a\u52d8\u6d4b\u5b9a\u4f4d<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9488\u5bf9\u5916\u673a\u4f4d\u5b89\u88c5\u6761\u4ef6\u3001\u5c42\u9ad8\u3001\u6881\u67f1\u4f4d\u7f6e\u3001\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u7b49\u8fdb\u884c\u5b9e\u5730\u786e\u8ba4\uff0c\u4e3a\u7cbe\u786e\u8bbe\u8ba1\u63d0\u4f9b\u4f9d\u636e\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u52d8\u6d4b-01\uff1a\u5916\u673a\u4f4d\u2014\u20148\u697c\u9633\u53f0\/\u8bbe\u5907\u5e73\u53f0\uff0c\u786e\u8ba4\u5b89\u88c5\u6761\u4ef6<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u52d8\u6d4b-02\uff1a\u5ba2\u538551\u33a1\u7a7a\u95f4\u2014\u2014\u786e\u8ba4\u53cc\u98ce\u76d8\u5b9a\u4f4d\u65b9\u6848<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u52d8\u6d4b-03\uff1a\u5404\u623f\u95f4\u6881\u67f1\u3001\u540a\u9876\u9ad8\u5ea6\u590d\u6838<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u52d8\u6d4b-04\uff1a\u5730\u6696\u5206\u96c6\u6c34\u5668\u4f4d\u7f6e\u786e\u8ba4\uff086\u8def\uff09<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u52d8\u6d4b-05\uff1a\u4e3b\u673a\u7ba1\u8def\u8d70\u5411\u786e\u8ba4<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\">\u52d8\u6d4b-06\uff1a\u7535\u6e90\u4f4d\u7f6e\u786e\u8ba4\uff08\u5355\u76f8\u7535\uff09<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"457\" height=\"813\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg\" alt=\"\" class=\"wp-image-4094\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg 457w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01-169x300.jpg 169w\" sizes=\"auto, (max-width: 457px) 100vw, 457px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"457\" height=\"813\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-02.jpg\" alt=\"\" class=\"wp-image-4095\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-02.jpg 457w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-02-169x300.jpg 169w\" sizes=\"auto, (max-width: 457px) 100vw, 457px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"sjtz10\" class=\"wp-block-heading\">\u5341\u3001\u8bbe\u8ba1\u56fe\u7eb8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u51b7\u8d1f\u8377\u6838\u7b97\u3001\u5185\u673a\u914d\u7f6e\u3001\u5730\u6696\u76d8\u7ba1\u5206\u533a\u53ca\u7ba1\u8def\u8bbe\u8ba1\u56fe\u2014\u2014\u4e25\u683c\u4f9d\u636e GB 50736-2012 \u6807\u51c6\u8ba1\u7b97\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-01.jpg\" alt=\"\" class=\"wp-image-4096\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-01.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-01-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-01-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-02.jpg\" alt=\"\" class=\"wp-image-4097\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-02.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-02-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-02-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-03.jpg\" alt=\"\" class=\"wp-image-4098\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-03.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-03-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-03-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-04.jpg\" alt=\"\" class=\"wp-image-4099\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-04.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-04-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-04-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-05.jpg\" alt=\"\" class=\"wp-image-4100\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-05.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-05-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-05-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-06.jpg\" alt=\"\" class=\"wp-image-4101\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-06.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-06-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-sgtz-06-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"sgxczp11\" class=\"wp-block-heading\">\u5341\u4e00\u3001\u65bd\u5de5\u73b0\u573a\u7167\u7247<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-03.jpg\" alt=\"\" class=\"wp-image-4102\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-03.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-03-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-03-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-06.jpg\" alt=\"\" class=\"wp-image-4103\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-06.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-06-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-06-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-09.jpg\" alt=\"\" class=\"wp-image-4104\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-09.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-09-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-09-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"814\" height=\"611\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-14.jpg\" alt=\"\" class=\"wp-image-4105\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-14.jpg 814w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-14-300x225.jpg 300w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-14-768x576.jpg 768w\" sizes=\"auto, (max-width: 814px) 100vw, 814px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-01-1.jpg\" alt=\"\" class=\"wp-image-4110\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-01-1.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-01-1-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-02.jpg\" alt=\"\" class=\"wp-image-4107\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-02.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-02-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-05.jpg\" alt=\"\" class=\"wp-image-4108\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-05.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-05-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-12.jpg\" alt=\"\" class=\"wp-image-4109\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-12.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-ktsgt-12-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 id=\"dnsg12\" class=\"wp-block-heading\">\u5341\u4e8c\u3001\u5730\u6696\u65bd\u5de5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e25\u683c\u6309\u7167\u8bbe\u8ba1\u56fe\u7eb8\u65bd\u5de5\uff0c\u6bcf\u9053\u5de5\u5e8f\u5bf9\u5e94\u56fe\u7eb8\u70b9\u4f4d\u9010\u4e00\u6838\u5bf9\uff0c\u786e\u4fdd\u843d\u5730\u4e0e\u8bbe\u8ba1\u4e00\u81f4\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-01.jpg\" alt=\"\" class=\"wp-image-4116\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-01.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-01-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-02.jpg\" alt=\"\" class=\"wp-image-4118\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-02.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-02-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-03.jpg\" alt=\"\" class=\"wp-image-4119\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-03.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-03-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-04.jpg\" alt=\"\" class=\"wp-image-4120\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-04.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-04-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-05.jpg\" alt=\"\" class=\"wp-image-4121\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-05.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-05-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-06.jpg\" alt=\"\" class=\"wp-image-4122\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-06.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-06-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-07.jpg\" alt=\"\" class=\"wp-image-4123\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-07.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-07-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-14.jpg\" alt=\"\" class=\"wp-image-4130\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-14.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-14-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-09.jpg\" alt=\"\" class=\"wp-image-4125\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-09.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-09-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-10.jpg\" alt=\"\" class=\"wp-image-4126\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-10.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-10-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-15.jpg\" alt=\"\" class=\"wp-image-4131\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-15.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-15-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-12.jpg\" alt=\"\" class=\"wp-image-4128\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-12.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-dnsgt-12-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 id=\"jlys13\" class=\"wp-block-heading\">\u5341\u4e09\u3001\u76d1\u7406\u9a8c\u6536<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u65bd\u5de5\u8fc7\u7a0b\u4e2d\u76d1\u7406\u5de1\u68c0\uff0c\u786e\u4fdd\u5de5\u7a0b\u8d28\u91cf\u2014\u2014\u6392\u6c34\u5761\u5ea6\u3001\u7ba1\u9053\u6c14\u5bc6\u6027\u7b49\u5173\u952e\u8282\u70b9\u9010\u9879\u6838\u9a8c\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-01.jpg\" alt=\"\" class=\"wp-image-4132\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-01.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-01-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-10.jpg\" alt=\"\" class=\"wp-image-4134\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-10.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-10-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-03.jpg\" alt=\"\" class=\"wp-image-4135\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-03.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-03-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-04.jpg\" alt=\"\" class=\"wp-image-4136\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-04.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-04-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-05.jpg\" alt=\"\" class=\"wp-image-4137\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-05.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-05-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-06.jpg\" alt=\"\" class=\"wp-image-4138\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-06.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-06-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-07.jpg\" alt=\"\" class=\"wp-image-4139\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-07.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-07-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"611\" height=\"814\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-09.jpg\" alt=\"\" class=\"wp-image-4140\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-09.jpg 611w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-09-225x300.jpg 225w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"800\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-11.jpg\" alt=\"\" class=\"wp-image-4141\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-11.jpg 600w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-jl-11-225x300.jpg 225w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<h2 id=\"shfwjl14\" class=\"wp-block-heading\">\u5341\u56db\u3001\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7cfb\u7edf\u8c03\u8bd5\u62a5\u544a\u3001\u4f7f\u7528\u6307\u5bfc\u7b7e\u6536\u3001\u4fdd\u4fee\u5361\u53d1\u653e\u3001\u56de\u8bbf\u8bb0\u5f55\u7b49\u552e\u540e\u670d\u52a1\u5185\u5bb9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u8c03\u8bd5\u8bb0\u5f55<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9\uff08\u5f85\u6dfb\u52a0\uff09<\/th><\/tr><tr><td>\u8c03\u8bd5\u65e5\u671f<\/td><td>\u3000<\/td><\/tr><tr><td>\u8c03\u8bd5\u4eba\u5458<\/td><td>\u3000<\/td><\/tr><tr><td>\u5236\u51b7\u8bd5\u8fd0\u884c\u53c2\u6570<\/td><td>\u3000<\/td><\/tr><tr><td>\u5236\u70ed\/\u5730\u6696\u8bd5\u8fd0\u884c\u53c2\u6570<\/td><td>\u3000<\/td><\/tr><tr><td>\u7cfb\u7edf\u8fd0\u884c\u566a\u97f3<\/td><td>\u3000<\/td><\/tr><tr><td>\u5ba2\u6237\u7b7e\u6536<\/td><td>\u3000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u4f7f\u7528\u6559\u5b66<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5b8c\u6210\u60c5\u51b5<\/th><\/tr><tr><td>\u7a7a\u8c03\u64cd\u4f5c\u6559\u5b66<\/td><td>\u2610<\/td><\/tr><tr><td>\u5730\u6696\u64cd\u4f5c\u6559\u5b66<\/td><td>\u2610<\/td><\/tr><tr><td>WiFi\u6e29\u63a7\u5668\u4f7f\u7528<\/td><td>\u2610<\/td><\/tr><tr><td>\u624b\u673a\u8fdc\u7a0b\u63a7\u5236\u6559\u5b66<\/td><td>\u2610<\/td><\/tr><tr><td>\u6ee4\u7f51\u6e05\u6d17\u5468\u671f\u8bf4\u660e<\/td><td>\u2610<\/td><\/tr><tr><td>\u4f7f\u7528\u8bf4\u660e\u4e66\u4ea4\u4ed8<\/td><td>\u2610<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u4fdd\u4fee\u4fe1\u606f<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u9879\u76ee<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5185\u5bb9\uff08\u5f85\u6dfb\u52a0\uff09<\/th><\/tr><tr><td>\u4fdd\u4fee\u5361\u7f16\u53f7<\/td><td>\u3000<\/td><\/tr><tr><td>\u4fdd\u4fee\u8d77\u59cb\u65e5<\/td><td>\u3000<\/td><\/tr><tr><td>\u4e3b\u673a\u5ef6\u4fdd\u81f3<\/td><td>10\u5e74\uff08\u5165\u4f1a\uff09<\/td><\/tr><tr><td>\u7ba1\u9053\u8d28\u4fdd<\/td><td>50\u5e74\uff08\u4f1f\u661f\uff09<\/td><\/tr><tr><td>\u5de5\u7a0b\u8d28\u4fdd\u671f<\/td><td>5\u5e74\uff08\u4f1a\u5458\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u56de\u8bbf\u8bb0\u5f55<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u6b21\u6570<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u65e5\u671f<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u56de\u8bbf\u5185\u5bb9<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5ba2\u6237\u53cd\u9988<\/th><th class=\"has-text-align-left\" data-align=\"left\">\u5904\u7406\u7ed3\u679c<\/th><\/tr><tr><td>\u7b2c1\u6b21<\/td><td>\u3000<\/td><td>\u3000<\/td><td>\u3000<\/td><td>\u3000<\/td><\/tr><tr><td>\u7b2c2\u6b21<\/td><td>\u3000<\/td><td>\u3000<\/td><td>\u3000<\/td><td>\u3000<\/td><\/tr><tr><td>\u5e74\u5ea6<\/td><td>\u3000<\/td><td>\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><td>\u3000<\/td><td>\u3000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u5341\u4e94\u3001\u65b9\u6848\u987e\u95ee<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc69\u200d\ud83d\udcbc <strong>\u90ed\u52c7\u79c0<\/strong> \u00b7 \u9f99\u8109\u6696\u901a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcf1 181-0083-9248<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83c\udfe2 \u65e5\u7acb\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u59cb\u4e8e2004 \u00b7 \u94bb\u77f3\u5b89\u88c5\u5546\uff082025\u5e74\u5ea6\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccd \u5357\u5bcc\u68ee\uff1a\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348 \uff5c \u5317\u5bcc\u68ee\uff1a\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45A\u5e625\u697cA5135<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udcde \u95e8\u5e97\u70ed\u7ebf\uff1a028-86131795 \/ 028-65272586<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">\u6848\u4f8b\u7248\u672c V1.0 \u00b7 \u5efa\u6863 2026\u5e743\u670818\u65e5<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u65b9\u6848\u6240\u6709\u6280\u672f\u53c2\u6570\u5f15\u7528 GB 50736-2012 \u53ca\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u624b\u518c\uff0c\u53ef\u72ec\u7acb\u9a8c\u8bc1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8700ICP\u59072026015986\u53f7 \u00a9 2004-2026 \u9f99\u8109\u6696\u901a \u7248\u6743\u6240\u6709<\/p>\n\n\n\n<style>\n\/* ===== \u8868\u683c\u7f8e\u5316 ===== *\/\n.wp-block-table table {\n  border-collapse: collapse; width: 100%; margin: 14px 0;\n  font-size: 0.92em; border-radius: 8px; overflow: hidden;\n  box-shadow: 0 1px 4px rgba(0,0,0,0.06);\n}\n.wp-block-table th {\n  background: #1a3a5c; color: #fff; padding: 10px 14px; text-align: left;\n}\n.wp-block-table td {\n  padding: 9px 14px; border-bottom: 1px solid #e8edf2;\n}\n.wp-block-table tr:nth-child(even) td { background: #f6f9fc; }\n\n\/* ===== \u6807\u9898\u7f8e\u5316 ===== *\/\nh2.wp-block-heading {\n  color: #1a3a5c; border-bottom: 2px solid #1a3a5c;\n  padding-bottom: 8px; margin: 24px 0 14px;\n  cursor: pointer; user-select: none;\n  display: flex; align-items: center; gap: 8px;\n}\nh2.wp-block-heading:hover { opacity: 0.85; }\nh2.wp-block-heading::after {\n  content: \"\u25bc\"; font-size: 0.7em; margin-left: auto;\n  transition: transform 0.3s; opacity: 0.5;\n}\nh2.wp-block-heading.accordion-open::after {\n  transform: rotate(180deg);\n}\nh1.wp-block-heading {\n  text-align: center; color: #1a3a5c;\n  border-bottom: 3px solid #1a3a5c; padding-bottom: 12px;\n}\n\n\/* ===== \u624b\u98ce\u7434\u5185\u5bb9\uff08\u521d\u59cb\u9690\u85cf\uff09 ===== *\/\n.accordion-panel {\n  max-height: 0; overflow: hidden;\n  transition: max-height 0.5s ease;\n}\n.accordion-panel.open { max-height: 8000px; }\n<\/style>\n\n<script>\n(function(){\n  var h2s = document.querySelectorAll('h2.wp-block-heading');\n  h2s.forEach(function(h2){\n    \/\/ H2 \u5b8c\u5168\u4e0d\u52a8\uff0cid \u4fdd\u7559\uff0c\u951a\u70b9\u4e0d\u53d7\u5f71\u54cd\n    var panel = document.createElement('div');\n    panel.className = 'accordion-panel';\n    \n    \/\/ \u628a H2 \u540e\u9762\u76f4\u5230\u4e0b\u4e00\u4e2a H2 \u7684\u5185\u5bb9\u5168\u90e8\u79fb\u5165 panel\n    var next = h2.nextSibling;\n    while(next){\n      if(next.nodeType===1 && next.tagName==='H2') break;\n      var move = next;\n      next = next.nextSibling;\n      panel.appendChild(move);\n    }\n    \n    \/\/ panel \u63d2\u5728 H2 \u540e\u9762\n    h2.parentNode.insertBefore(panel, h2.nextSibling);\n    \n    \/\/ \u70b9\u51fb H2 \u5c55\u5f00\/\u6536\u8d77\n    h2.addEventListener('click', function(){\n      var isOpen = panel.classList.contains('open');\n      \/\/ \u5173\u95ed\u6240\u6709\n      document.querySelectorAll('.accordion-panel.open').forEach(function(p){ p.classList.remove('open'); });\n      document.querySelectorAll('h2.accordion-open').forEach(function(h){ h.classList.remove('accordion-open'); });\n      \/\/ \u6253\u5f00\u5f53\u524d\n      if(!isOpen){\n        panel.classList.add('open');\n        h2.classList.add('accordion-open');\n        \/\/ \u76ee\u5f55\u8df3\u8f6c\u65f6\u81ea\u52a8\u5c55\u5f00\n        setTimeout(function(){ h2.scrollIntoView({behavior:'smooth',block:'start'}); }, 100);\n      }\n    });\n  });\n  \n  \/\/ \u9875\u9762\u52a0\u8f7d\u65f6\uff0c\u5982\u679c URL \u6709 hash\uff0c\u81ea\u52a8\u5c55\u5f00\u5bf9\u5e94\u7ae0\u8282\n  if(location.hash){\n    var target = document.querySelector(location.hash);\n    if(target && target.tagName==='H2'){\n      var panel = target.nextSibling;\n      if(panel && panel.classList.contains('accordion-panel')){\n        panel.classList.add('open');\n        target.classList.add('accordion-open');\n        setTimeout(function(){ target.scrollIntoView({behavior:'smooth',block:'start'}); }, 200);\n      }\n    }\n  }\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u7965\u57df4-1-804 \u00b7 \u6c6a\u8001\u5e08\u65e5\u7acb\u6c34\u5885\u9002 [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-1991","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u7965\u57df4-1-804 \u00b7 \u6c6a\u8001\u5e08\u65e5\u7acb\u6c34\u5885\u9002 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=1991\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-23T02:44:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"457\" \/>\n\t<meta property=\"og:image:height\" content=\"813\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991\",\"name\":\"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg\",\"datePublished\":\"2026-06-02T05:29:44+00:00\",\"dateModified\":\"2026-10-23T02:44:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg\",\"width\":457,\"height\":813},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=1991#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"zh_CN","og_type":"article","og_title":"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u7965\u57df4-1-804 \u00b7 \u6c6a\u8001\u5e08\u65e5\u7acb\u6c34\u5885\u9002 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=1991","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-23T02:44:38+00:00","og_image":[{"width":457,"height":813,"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"11 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=1991","url":"https:\/\/longmai-nt.com\/?page_id=1991","name":"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=1991#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=1991#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg","datePublished":"2026-06-02T05:29:44+00:00","dateModified":"2026-10-23T02:44:38+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=1991#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=1991"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=1991#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/xiangyu-4-1-801-wanglaoshi-xcdw-01.jpg","width":457,"height":813},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=1991#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u7965\u57df4-1-804\uff0c\u65e5\u7acb\u6c34\u5885\u9002160\u62d6\u4e94\u6863\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1991"}],"version-history":[{"count":34,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1991\/revisions"}],"predecessor-version":[{"id":14851,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/1991\/revisions\/14851"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}