{"id":20725,"date":"2026-11-18T00:29:42","date_gmt":"2026-11-17T16:29:42","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=20725"},"modified":"2026-11-19T00:13:43","modified_gmt":"2026-11-18T16:13:43","slug":"%e9%a3%8e%e6%9c%ba%e7%9b%98%e7%ae%a1%e6%80%8e%e4%b9%88%e9%80%89%ef%bc%9f%e5%8d%8a%e5%8c%85%e5%bc%8f%e3%80%81%e5%85%a8%e7%9b%b4%e6%b5%81%e5%8f%98%e9%a2%91%e3%80%81%e5%b8%a6pe%e5%87%80%e5%8c%96%e4%b8%89","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=20725","title":{"rendered":"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05"},"content":{"rendered":"<style>\n.lmnt-body{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#2b2b2b;line-height:1.75;font-size:16px;}\n.lmnt-body h2{color:#1a3a6e;font-size:21px;line-height:1.4;border-bottom:2px solid #e3e8f0;padding-bottom:6px;margin:30px 0 14px;}\n.lmnt-body h3{color:#243b5e;font-size:17px;line-height:1.5;margin:22px 0 8px;}\n.lmnt-body p{margin:13px 0;}\n.lmnt-body b{color:#1a3a6e;}\n.lmnt-body a{color:#1a5fb4;text-decoration:underline;}\n.lmnt-body ul{padding-left:22px;margin:13px 0;}\n.lmnt-body li{margin:7px 0;}\n.lmnt-body .lm-blockquote{border-left:4px solid #1a3a6e;background:#f5f7fb;padding:14px 18px;margin:16px 0;color:#243b5e;border-radius:0 6px 6px 0;}\n.lmnt-body .lm-table{width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;}\n.lmnt-body .lm-table th,.lmnt-body .lm-table td{border:1px solid #dde3ec;padding:8px 10px;text-align:left;vertical-align:top;line-height:1.65;}\n.lmnt-body .lm-table th{background:#eef3fb;color:#1a3a6e;font-weight:600;}\n.lmnt-body .lm-table td{color:#2b2b2b;}\n.lmnt-body .lm-note{border-left:4px solid #c8a415;background:#fffdf3;padding:12px 16px;margin:14px 0;color:#6b5810;border-radius:0 6px 6px 0;}\n.lmnt-body .lm-viz{background:#fbfcfe;border:1px solid #e3e8f0;border-radius:10px;padding:14px;margin:18px 0;overflow-x:auto;}\n.lmnt-body .lm-viz svg{display:block;min-width:600px;width:100%;height:auto;}\n.lmnt-body .lm-figcap{font-size:13px;color:#6b7789;margin:6px 0 0;text-align:center;}\n.lmnt-body .lm-fig{margin:20px 0;text-align:center;}\n.lmnt-body .lm-fig img{max-width:100%;height:auto;border:1px solid #e3e8f0;border-radius:8px;}\n@media(max-width:600px){.lmnt-body{font-size:15px;}.lmnt-body h2{font-size:19px;}.lmnt-body h3{font-size:16px;}.lmnt-body .lm-table{font-size:13.5px;}.lmnt-body .lm-table th,.lmnt-body .lm-table td{padding:6px 7px;}}\n<\/style>\n<div class=\"lm-geo\" data-layer=\"\u6839\" data-cat=\"\u4e2d\u592e\u7a7a\u8c03\" data-code=\"\" data-step=\"3\" data-face=\"\u5206\u6790\" data-elem=\"\u672b\u7aef\" data-q=\"\u98ce\u673a\u76d8\u7ba1\u4e09\u5c42\u6b21\u600e\u4e48\u9009\u4e0e\u96f6\u8d8a\u53c2\u6570\u51c0\u5316\u53e3\u5f84\"><\/div>\n<div class=\"lmnt-body\">\n<blockquote class=\"lm-blockquote\">\n<p>\"\u540c\u6837\u662f\u98ce\u673a\u76d8\u7ba1\uff0c\u6709\u7684\u4e00\u53f0\u51e0\u767e\u5757\uff0c\u6709\u7684\u51e0\u5343\u5757\uff0c\u9500\u552e\u8bf4\u4e00\u4e2a\u662f\u5de5\u7a0b\u673a\u3001\u4e00\u4e2a\u662f\u5bb6\u7528\u76f4\u6d41\u53d8\u9891\uff0c\u8fd8\u5e26\u51c0\u5316\u2014\u2014\u5230\u5e95\u5dee\u5728\u54ea\uff0c\u8fd9\u4e2a\u5dee\u4ef7\u82b1\u5f97\u503c\u4e0d\u503c\uff1f\"<\/p>\n<\/blockquote>\n<h2 class=\"lm-h2\">\u5148\u8bf4\u7ed3\u8bba\uff1a\u98ce\u76d8\u7684\u5dee\u5f02\uff0c\u5728\u7ed3\u6784\u5c42\u6b21\u4e0d\u5728\u540d\u5b57<\/h2>\n<p>\u98ce\u673a\u76d8\u7ba1\u662f\u4e2d\u592e\u7a7a\u8c03\u548c\u4e24\u8054\u4f9b\u7cfb\u7edf\u91cc\u8d1f\u8d23\u5411\u623f\u95f4\u9001\u51b7\u9001\u70ed\u7684\u672b\u7aef\u3002\u5e02\u9762\u4e0a\u770b\u7740\u5dee\u4e0d\u591a\u7684\u98ce\u76d8\uff0c\u5b9e\u9645\u5206\u4e09\u4e2a\u5c42\u6b21\uff1a<b>\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8<\/b>\u3002\u5b83\u4eec\u7684\u533a\u522b\u4e0d\u662f\u8425\u9500\u8bdd\u672f\uff0c\u800c\u662f\u63a5\u6c34\u76d8\u5728\u4e0d\u5728\u673a\u8eab\u91cc\u3001\u6709\u6ca1\u6709\u4fdd\u6e29\u68c9\u3001\u7528\u4ec0\u4e48\u7535\u673a\u3001\u600e\u4e48\u6392\u6c34\u2014\u2014\u8fd9\u4e9b\u76f4\u63a5\u51b3\u5b9a\u4f1a\u4e0d\u4f1a\u51dd\u9732\u6253\u6e7f\u540a\u9876\u3001\u566a\u97f3\u5927\u4e0d\u5927\u3001\u540e\u671f\u8981\u4e0d\u8981\u9891\u7e41\u7ef4\u62a4\u3002\u8fd9\u9875\u4e00\u6b21\u8bb2\u6e05\u4e09\u5c42\u600e\u4e48\u5206\u3001\u53c2\u6570\u600e\u4e48\u770b\u3001\u6309\u4ec0\u4e48\u987a\u5e8f\u9009\u3002<\/p>\n<h2 class=\"lm-h2\">\u7b2c\u4e00\u5c42\uff1a\u534a\u5305\u5f0f\u98ce\u76d8\uff0c\u5de5\u7a0b\u673a\u7684\u516d\u4e2a\u77ed\u677f<\/h2>\n<p>\u534a\u5305\u5f0f\u662f\"\u534a\u5305\"\uff0c\u4e0d\u662f\"\u5168\u5305\"\u2014\u2014\u63a5\u6c34\u76d8\u5916\u7f6e\u3001\u673a\u8eab\u6ca1\u6709\u4fdd\u6e29\u68c9\uff0c\u8fd9\u662f\u5b83\u548c\u5bb6\u7528\u98ce\u76d8\u7684\u5206\u6c34\u5cad\u3002\u5b83\u7684\u7279\u70b9\u4e0e\u4ee3\u4ef7\u5982\u4e0b\uff1a<\/p>\n<table class=\"lm-table\">\n<thead>\n<tr>\n<th>\u7ed3\u6784\u7279\u70b9<\/th>\n<th>\u5e26\u6765\u7684\u95ee\u9898<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u63a5\u6c34\u76d8\u5916\u7f6e\u3001\u65e0\u4fdd\u6e29\u68c9<\/td>\n<td>\u673a\u7ec4\u8fd0\u884c\u540e\u51b7\u8868\u9762\u5bb9\u6613\u51dd\u9732\uff0c\u6253\u6e7f\u5929\u82b1\u677f\u3001\u7834\u574f\u88c5\u4fee\uff0c\u4e25\u91cd\u65f6\u8981\u62c6\u9876\u7ef4\u4fee<\/td>\n<\/tr>\n<tr>\n<td>\u9700\u53e6\u52a0\u5916\u7f6e\u63a5\u6c34\u76d8<\/td>\n<td>\u51b7\u51dd\u6c34\u8981\u9760\u5916\u7f6e\u63a5\u6c34\u76d8\u6536\u96c6\u518d\u6392\u8d70\uff0c\u591a\u4e00\u9053\u5b89\u88c5\u73af\u8282<\/td>\n<\/tr>\n<tr>\n<td>\u540a\u9876\u9ad8\u5ea6\u8981\u6c42\u9ad8<\/td>\n<td>\u7ea6\u970035\u516c\u5206\u5de6\u53f3\uff0c\u540a\u9876\u89c2\u611f\u539a\u91cd<\/td>\n<\/tr>\n<tr>\n<td>\u65e0\u6392\u6c34\u6cf5\u3001\u9760\u91cd\u529b\u5761\u5ea6<\/td>\n<td>\u6392\u6c34\u4e0d\u5f7b\u5e95\uff0c\u76d8\u4e2d\u957f\u671f\u5b58\u6c34\u79ef\u7070\uff0c\u5bb9\u6613\u6ecb\u751f\u7ec6\u83cc<\/td>\n<\/tr>\n<tr>\n<td>\u4ea4\u6d41\u5b9a\u9891\u7535\u673a<\/td>\n<td>\u566a\u97f3\u504f\u9ad8\uff0c\u8c03\u901f\u6863\u4f4d\u5c11<\/td>\n<\/tr>\n<tr>\n<td>\u9700\u5b9a\u671f\u6e05\u6d17\u7ef4\u62a4<\/td>\n<td>\u957f\u671f\u6f6e\u6e7f\u73af\u5883\u4e0b\u6709\u9709\u83cc\u548c\u7a7a\u6c14\u4e8c\u6b21\u6c61\u67d3\u98ce\u9669<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"lm-note\">\u8bf4\u660e\uff1a\u4ee5\u4e0a\u534a\u5305\u5f0f\u7684\u7ed3\u6784\u662f\u5de5\u7a0b\u673a\u7684\u666e\u904d\u7279\u70b9\uff0c\u4e0d\u662f\u9488\u5bf9\u4efb\u4f55\u4e00\u4e2a\u54c1\u724c\uff1b\u521d\u6295\u6210\u672c\u4f4e\u662f\u5b83\u7684\u4f18\u52bf\uff0c\u95ee\u9898\u5728\u4e8e\u5bb6\u7528\u957f\u671f\u4f7f\u7528\u573a\u666f\u4e0b\u51dd\u9732\u3001\u566a\u97f3\u4e0e\u7ef4\u62a4\u6210\u672c\u3002\u9009\u5b83\u8fd8\u662f\u9009\u5bb6\u7528\u673a\uff0c\u770b\u4f7f\u7528\u573a\u666f\u548c\u9884\u7b97\u3002\u8981\u63d0\u9192\u4e00\u53e5\uff1a\u5bb6\u7528\u82e5\u575a\u6301\u9009\u534a\u5305\u5f0f\uff0c\u5373\u4fbf\u73b0\u573a\u8865\u505a\u5916\u7f6e\u63a5\u6c34\u76d8\u3001\u52a0\u539a\u4fdd\u6e29\u3001\u505a\u597d\u5e26\u5761\u5ea6\u7684\u91cd\u529b\u6392\u6c34\uff0c\u4e5f\u96be\u4ee5\u5b8c\u5168\u6d88\u9664\u51dd\u9732\u79ef\u6c34\u9690\u60a3\uff0c\u540e\u671f\u7ef4\u62a4\u538b\u529b\u4f1a\u8f6c\u79fb\u5230\u88c5\u4fee\u4ea4\u4ed8\u4e4b\u540e\u3002<\/div>\n<h2 class=\"lm-h2\">\u7b2c\u4e8c\u5c42\uff1a\u5168\u76f4\u6d41\u53d8\u9891\u98ce\u76d8\uff0c\u5bb6\u7528\u7684\u4e3b\u6d41\u9009\u62e9<\/h2>\n<p>\u4ee5\u65e5\u7acb\u96f6\u8d8a\u6807\u51c6\u578b\u8d85\u8584DC\u98ce\u673a\u76d8\u7ba1\u4e3a\u4ee3\u8868\uff0c\u578b\u53f7 RFP-\u00d7\u00d7WAR\/DBT12Y(Z)03(\/P)\uff0c\u5bb9\u91cf\u516d\u6863\uff0834\/51\/68\/85\/102\/119\uff09\u3002\u5b83\u628a\u534a\u5305\u5f0f\u7684\u51e0\u4e2a\u77ed\u677f\u5728\u51fa\u5382\u5c31\u89e3\u51b3\u6389\uff1a<\/p>\n<div class=\"lm-viz\">\n<svg viewBox=\"0 0 640 300\" role=\"img\" aria-label=\"\u4e09\u7c7b\u98ce\u673a\u76d8\u7ba1\u7ed3\u6784\u5c42\u6b21\u5bf9\u6bd4\u793a\u610f\u56fe\">\n  <text x=\"320\" y=\"22\" text-anchor=\"middle\" font-size=\"15\" font-weight=\"bold\" fill=\"#1a3a6e\">\u98ce\u673a\u76d8\u7ba1\u7684\u4e09\u4e2a\u5c42\u6b21\uff1a\u7ed3\u6784\u51b3\u5b9a\u4f53\u9a8c\u4e0e\u6210\u672c<\/text>\n  <!-- \u5de6 \u534a\u5305 -->\n  <rect x=\"25\" y=\"45\" width=\"185\" height=\"230\" rx=\"10\" fill=\"#fdf2f0\" stroke=\"#c0392b\"\/>\n  <text x=\"117\" y=\"70\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"bold\" fill=\"#c0392b\">\u2460 \u534a\u5305\u5f0f\uff08\u5de5\u7a0b\u673a\uff09<\/text>\n  <rect x=\"45\" y=\"84\" width=\"145\" height=\"66\" rx=\"6\" fill=\"#fff\" stroke=\"#c0392b\"\/>\n  <text x=\"117\" y=\"104\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u63a5\u6c34\u76d8\u5916\u7f6e<\/text>\n  <text x=\"117\" y=\"122\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u65e0\u4fdd\u6e29\u68c9<\/text>\n  <text x=\"117\" y=\"140\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u4ea4\u6d41\u5b9a\u9891\u7535\u673a<\/text>\n  <text x=\"117\" y=\"172\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#c0392b\">\u91cd\u529b\u6392\u6c34 \u00b7 \u6613\u51dd\u9732<\/text>\n  <text x=\"117\" y=\"194\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#c0392b\">\u566a\u97f3\u9ad8 \u00b7 \u540a\u9876\u539a<\/text>\n  <text x=\"117\" y=\"222\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#6b7789\">\u6210\u672c\u4f4e\uff0c\u5546\u7528\/\u4f4e\u4ef7\u9879\u76ee<\/text>\n  <text x=\"117\" y=\"248\" text-anchor=\"middle\" font-size=\"11\" font-weight=\"bold\" fill=\"#c0392b\">\u5dee\u4ef7\u57fa\u51c6<\/text>\n  <!-- \u4e2d \u5168\u76f4\u6d41 -->\n  <rect x=\"228\" y=\"45\" width=\"185\" height=\"230\" rx=\"10\" fill=\"#eef3fb\" stroke=\"#1a3a6e\"\/>\n  <text x=\"320\" y=\"70\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"bold\" fill=\"#1a3a6e\">\u2461 \u5168\u76f4\u6d41\u53d8\u9891\uff08\u5bb6\u7528\uff09<\/text>\n  <rect x=\"248\" y=\"84\" width=\"145\" height=\"66\" rx=\"6\" fill=\"#fff\" stroke=\"#1a3a6e\"\/>\n  <text x=\"320\" y=\"104\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u5185\u7f6eABS\u63a5\u6c34\u76d8<\/text>\n  <text x=\"320\" y=\"122\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u5168\u5305\u4fdd\u6e29+\u51b7\u6865\u5904\u7406<\/text>\n  <text x=\"320\" y=\"140\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u76f4\u6d41\u65e0\u5237\u7535\u673a<\/text>\n  <text x=\"320\" y=\"172\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#1a3a6e\">1200mm\u63d0\u5347\u6cf5+\u6d6e\u5b50<\/text>\n  <text x=\"320\" y=\"194\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#1a3a6e\">\u6700\u4f4e20dB \u00b7 192mm\u8584<\/text>\n  <text x=\"320\" y=\"222\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#6b7789\">\u65e5\u7acb\u96f6\u8d8a\u4e3a\u4ee3\u8868<\/text>\n  <text x=\"320\" y=\"248\" text-anchor=\"middle\" font-size=\"11\" font-weight=\"bold\" fill=\"#1a3a6e\">\u4e3b\u6d41\u5bb6\u7528\u4e4b\u9009<\/text>\n  <!-- \u53f3 +PE -->\n  <rect x=\"431\" y=\"45\" width=\"185\" height=\"230\" rx=\"10\" fill=\"#eef8f3\" stroke=\"#2d7a5f\"\/>\n  <text x=\"523\" y=\"70\" text-anchor=\"middle\" font-size=\"13\" font-weight=\"bold\" fill=\"#2d7a5f\">\u2462 \u96f6\u8d8a + PE\u51c0\u5316<\/text>\n  <rect x=\"451\" y=\"84\" width=\"145\" height=\"66\" rx=\"6\" fill=\"#fff\" stroke=\"#2d7a5f\"\/>\n  <text x=\"523\" y=\"104\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u5728\u2461\u57fa\u7840\u4e0a<\/text>\n  <text x=\"523\" y=\"122\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u52a0PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757<\/text>\n  <text x=\"523\" y=\"140\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2b2b2b\">\u8d1f\u79bb\u5b50\u9664\u83cc\u9664\u5473<\/text>\n  <text x=\"523\" y=\"172\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#2d7a5f\">PM2.5 94.46%<\/text>\n  <text x=\"523\" y=\"194\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#2d7a5f\">\u5927\u80a0\u6746\u83cc99.16%<\/text>\n  <text x=\"523\" y=\"222\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#6b7789\">\u6a21\u5757\u514d\u6e05\u6d17\u514d\u66f4\u6362<\/text>\n  <text x=\"523\" y=\"248\" text-anchor=\"middle\" font-size=\"11\" font-weight=\"bold\" fill=\"#2d7a5f\">\u51c0\u5316\u9009\u914d<\/text>\n  <text x=\"320\" y=\"292\" text-anchor=\"middle\" font-size=\"10.5\" fill=\"#6b7789\">\u540c\u4e00\u53f0\u673a\u5668\uff0c\u7ed3\u6784\u5c42\u6b21\u4e0d\u540c\uff0c\u540a\u9876\u9ad8\u5ea6\u3001\u51dd\u9732\u98ce\u9669\u3001\u566a\u97f3\u4e0e\u540e\u671f\u7ef4\u62a4\u5dee\u522b\u660e\u663e<\/text>\n<\/svg><\/p>\n<p class=\"lm-figcap\">\u56fe 1\uff1a\u4e09\u7c7b\u98ce\u673a\u76d8\u7ba1\u7684\u7ed3\u6784\u5c42\u6b21\u2014\u2014\u8d8a\u5f80\u4e0a\u8d70\uff0c\u63a5\u6c34\u76d8\u3001\u4fdd\u6e29\u3001\u6392\u6c34\u3001\u7535\u673a\u548c\u51c0\u5316\u914d\u7f6e\u8d8a\u5b8c\u6574\u3002<\/p>\n<\/div>\n<div class=\"lm-note\">\u4e00\u53e5\u8bdd\u8bb0\u4f4f\uff1a\u534a\u5305\u5f0f\u628a\u95ee\u9898\u7559\u7ed9\u5b89\u88c5\u73b0\u573a\u548c\u4f7f\u7528\u540e\uff0c\u5168\u76f4\u6d41\u53d8\u9891\u628a\u95ee\u9898\u5728\u51fa\u5382\u524d\u5c31\u89e3\u51b3\u2014\u2014\u5185\u7f6e\u63a5\u6c34\u76d8\u3001\u5168\u5305\u4fdd\u6e29\u3001\u63d0\u5347\u6cf5\u52a0\u6d6e\u5b50\u5f00\u5173\u3001\u76f4\u6d41\u7535\u673a\uff0c\u8fd9\u56db\u9879\u662f\u5206\u6c34\u5cad\u3002<\/div>\n<h3>\u96f6\u8d8a\u516d\u6863\u6838\u5fc3\u53c2\u6570\uff08\u6837\u518c\u8d85\u9ad8\u901f\u6863\uff09<\/h3>\n<table class=\"lm-table\">\n<thead>\n<tr>\n<th>\u9879\u76ee<\/th>\n<th>34<\/th>\n<th>51<\/th>\n<th>68<\/th>\n<th>85<\/th>\n<th>102<\/th>\n<th>119<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u98ce\u91cf\u00b7\u8d85\u9ad8\uff08m\u00b3\/h\uff09<\/td>\n<td>340<\/td>\n<td>510<\/td>\n<td>680<\/td>\n<td>850<\/td>\n<td>1020<\/td>\n<td>1190<\/td>\n<\/tr>\n<tr>\n<td>\u8f93\u5165\u529f\u7387\uff08W\uff09<\/td>\n<td>20<\/td>\n<td>26<\/td>\n<td>36<\/td>\n<td>43<\/td>\n<td>56<\/td>\n<td>67<\/td>\n<\/tr>\n<tr>\n<td>\u5168\u70ed\u51b7\u91cf\uff08W\uff09<\/td>\n<td>2500<\/td>\n<td>3450<\/td>\n<td>4300<\/td>\n<td>5700<\/td>\n<td>6400<\/td>\n<td>6810<\/td>\n<\/tr>\n<tr>\n<td>\u663e\u70ed\u51b7\u91cf\uff08W\uff09<\/td>\n<td>1650<\/td>\n<td>2470<\/td>\n<td>2930<\/td>\n<td>3900<\/td>\n<td>4450<\/td>\n<td>4870<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u70ed\u91cf60\u2103\uff08W\uff09<\/td>\n<td>3800<\/td>\n<td>5500<\/td>\n<td>7000<\/td>\n<td>9100<\/td>\n<td>10400<\/td>\n<td>10950<\/td>\n<\/tr>\n<tr>\n<td>\u4f9b\u70ed\u91cf45\u2103\uff08W\uff09<\/td>\n<td>2370<\/td>\n<td>3450<\/td>\n<td>4300<\/td>\n<td>5700<\/td>\n<td>6400<\/td>\n<td>6700<\/td>\n<\/tr>\n<tr>\n<td>FCEER\uff08W\/W\uff09<\/td>\n<td>125<\/td>\n<td>140<\/td>\n<td>105<\/td>\n<td>110<\/td>\n<td>90<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>FCCOP\u00b760\u2103\uff08W\/W\uff09<\/td>\n<td>190<\/td>\n<td>220<\/td>\n<td>170<\/td>\n<td>180<\/td>\n<td>150<\/td>\n<td>138<\/td>\n<\/tr>\n<tr>\n<td>\u566a\u97f3\u00b7\u8d85\u9ad8~\u5fae\u98ce dB(A)<\/td>\n<td>31.5\/29\/27\/24\/22\/20<\/td>\n<td>35\/32\/29.5\/25\/23\/21<\/td>\n<td>40\/37\/34\/29\/25\/22<\/td>\n<td>40.5\/37\/33.5\/29\/25\/22<\/td>\n<td>43.5\/40\/37\/32\/27\/24<\/td>\n<td>45\/43\/39\/35\/30\/26<\/td>\n<\/tr>\n<tr>\n<td>\u5916\u5f62\u5c3a\u5bf8 H\u00d7W\u00d7D\uff08mm\uff09<\/td>\n<td>192\u00d7700\u00d7447<\/td>\n<td>192\u00d7910\u00d7447<\/td>\n<td>192\u00d7910\u00d7447<\/td>\n<td>192\u00d71180\u00d7447<\/td>\n<td>192\u00d71180\u00d7447<\/td>\n<td>192\u00d71180\u00d7447<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"lm-note\">\u5f15\u7528\u53c2\u6570\u5fc5\u5e26\u5de5\u51b5\uff1a\u4f9b\u51b7\/\u4f9b\u70ed\u91cf\u3001\u6c34\u6d41\u91cf\u3001\u6c34\u963b\u529b\u5747\u4e3a\u8d85\u9ad8\u901f\u6863\uff1b\u5236\u51b7\u8fdb\u98ce\u5e72\u6e7f\u740327\/19.5\u2103\u3001\u51b7\u51bb\u6c347\/12\u2103\uff0c\u5236\u70ed\u8fdb\u98ce\u5e72\u740321\u2103\u3001\u70ed\u6c34\u8fdb\u6c3460\u2103\uff1b\u989d\u5b9a\u98ce\u91cf\u4e3a\u6807\u51c6\u7a7a\u6c14\u72b6\u6001\u3001\u76d8\u7ba1\u5e72\u5de5\u51b5\uff08\u5e72\u740320\u2103\uff09\uff1b\u566a\u58f0\u4e3a\u534a\u6d88\u58f0\u5ba4\u6d4b\u8bd5\uff08GB\/T 19232-2019\uff09\u3002\u8131\u79bb\u5de5\u51b5\u8c08\u6570\u5b57\u6ca1\u6709\u610f\u4e49\u3002<\/div>\n<div class=\"lm-fig\"><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg\" alt=\"\u98ce\u673a\u76d8\u7ba1\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\u6548\u679c\u56fe\" loading=\"lazy\" \/><\/p>\n<p class=\"lm-figcap\">\u51b7\u51dd\u6c34\u63d0\u5347\u6cf5\uff1a\u5e26\u6cf5\u7684\u5bb6\u7528\u98ce\u76d8\u80fd\u628a\u51b7\u51dd\u6c34\u4e3b\u52a8\u6392\u8d70\uff0c\u907f\u514d\u91cd\u529b\u6392\u6c34\u4e0d\u5f7b\u5e95\u5e26\u6765\u7684\u79ef\u6c34\u548c\u7ec6\u83cc\u95ee\u9898<\/p>\n<\/div>\n<h2 class=\"lm-h2\">\u7b2c\u4e09\u5c42\uff1a\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8<\/h2>\n<p>\u5728\u5168\u76f4\u6d41\u53d8\u9891\u98ce\u76d8\u57fa\u7840\u4e0a\uff0c\u52a0\u88c5PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff08JK-LZA\uff09\uff0c\u5c31\u80fd\u5728\u9001\u51b7\u9001\u70ed\u7684\u540c\u65f6\u505a\u51c0\u5316\u3002\u539f\u7406\u662f\u8d1f\u79bb\u5b50\u6280\u672f\uff1a\u91ca\u653e\u9ad8\u6d3b\u6027\u5c0f\u7c92\u5f84\u8d1f\u79bb\u5b50\uff0c\u8ba9PM2.5\u9897\u7c92\u51dd\u805a\u6c89\u964d\u3001\u8ba9\u7ec6\u83cc\u7ed3\u6784\u6539\u53d8\u5931\u6d3b\uff0c\u5e76\u628a\u7532\u919b\u964d\u89e3\u4e3a\u4e8c\u6c27\u5316\u78b3\u548c\u6c34\u3002<\/p>\n<table class=\"lm-table\">\n<thead>\n<tr>\n<th>\u51c0\u5316\u9879\u76ee<\/th>\n<th>\u6837\u518c\u6807\u6ce8\u503c<\/th>\n<th>\u6d4b\u8bd5\u6761\u4ef6<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>PM2.5\u9897\u7c92\u7269\u51c0\u5316\u6548\u7387<\/td>\n<td>94.46%<\/td>\n<td>30\u7acb\u65b9\u7c73 \/ 2\u5c0f\u65f6<\/td>\n<\/tr>\n<tr>\n<td>\u5927\u80a0\u6746\u83cc\u51c0\u5316\u7387<\/td>\n<td>99.16%<\/td>\n<td>30\u7acb\u65b9\u7c73 \/ 2\u5c0f\u65f6<\/td>\n<\/tr>\n<tr>\n<td>\u7532\u578b\u6d41\u611f\u75c5\u6bd2H3N2\u51c0\u5316\u7387<\/td>\n<td>99.65%<\/td>\n<td>30\u7acb\u65b9\u7c73 \/ 1\u5c0f\u65f6<\/td>\n<\/tr>\n<tr>\n<td>\u9664\u786b\u5316\u6c22<\/td>\n<td>79.20%<\/td>\n<td>30\u7acb\u65b9\u7c73 \/ 24\u5c0f\u65f6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u8bd5\u9a8c\u6570\u636e\u6765\u81ea\u5e7f\u4e1c\u7701\u5fae\u751f\u7269\u5206\u6790\u68c0\u6d4b\u4e2d\u5fc3\u3002\u8981\u5982\u5b9e\u8bf4\u660e\uff1a\u8fd9\u662f\u7279\u5b9a\u5bb9\u79ef\u3001\u7279\u5b9a\u65f6\u957f\u4e0b\u7684\u5b9e\u9a8c\u5ba4\u6570\u636e\uff0c\u5bb6\u4e2d\u5b9e\u9645\u6548\u679c\u53d7\u623f\u95f4\u5927\u5c0f\u3001\u6c14\u5bc6\u6027\u3001\u5bb6\u5177\u906e\u6321\u548c\u8fd0\u884c\u65f6\u95f4\u5f71\u54cd\uff0c\u4e0d\u80fd\u5f53\u4fdd\u8bc1\u503c\u3002PE\u6a21\u5757\u662f\u9009\u914d\u4ef6\uff0c\u51c0\u5316\u578b\u5ba4\u5185\u673a\u624d\u662f\u6807\u914d\u2014\u2014\u8bf4\u7684\u662f\u4e0d\u540c\u673a\u578b\uff1b\u5b83\u65e0\u9700\u6e05\u6d17\u548c\u66f4\u6362\uff0c\u6bd4\u9700\u5b9a\u671f\u66f4\u6362\u7684\u6d3b\u6027\u70ad\u3001PM2.5\u6ee4\u7f51\u7701\u5fc3\u3002<\/p>\n<h2 class=\"lm-h2\">\u4e09\u7c7b\u98ce\u76d8\u6a2a\u5411\u5bf9\u6bd4<\/h2>\n<table class=\"lm-table\">\n<thead>\n<tr>\n<th>\u5bf9\u6bd4\u9879<\/th>\n<th>\u2460 \u534a\u5305\u5f0f\uff08\u5de5\u7a0b\u673a\uff09<\/th>\n<th>\u2461 \u5168\u76f4\u6d41\u53d8\u9891\uff08\u96f6\u8d8a\uff09<\/th>\n<th>\u2462 \u96f6\u8d8a+PE\u51c0\u5316<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u7535\u673a<\/td>\n<td>\u4ea4\u6d41\u5b9a\u9891<\/td>\n<td>\u76f4\u6d41\u65e0\u5237<\/td>\n<td>\u76f4\u6d41\u65e0\u5237<\/td>\n<\/tr>\n<tr>\n<td>\u63a5\u6c34\u76d8<\/td>\n<td>\u5916\u7f6e<\/td>\n<td>\u5185\u7f6eABS<\/td>\n<td>\u5185\u7f6eABS<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u6e29<\/td>\n<td>\u65e0<\/td>\n<td>EPP\u53d1\u6ce1+XPE+\u51b7\u6865\u5904\u7406<\/td>\n<td>\u540c\u5de6<\/td>\n<\/tr>\n<tr>\n<td>\u63d0\u5347\u6cf5<\/td>\n<td>\u65e0<\/td>\n<td>\u6807\u914d1200mm<\/td>\n<td>\u6807\u914d1200mm<\/td>\n<\/tr>\n<tr>\n<td>\u6d6e\u5b50\u5f00\u5173<\/td>\n<td>\u65e0<\/td>\n<td>\u6807\u914d<\/td>\n<td>\u6807\u914d<\/td>\n<\/tr>\n<tr>\n<td>\u51dd\u9732\u98ce\u9669<\/td>\n<td>\u9ad8<\/td>\n<td>\u4f4e<\/td>\n<td>\u4f4e<\/td>\n<\/tr>\n<tr>\n<td>\u6700\u4f4e\u566a\u97f3<\/td>\n<td>\u504f\u9ad8<\/td>\n<td>20dB(A)<\/td>\n<td>20dB(A)<\/td>\n<\/tr>\n<tr>\n<td>\u51c0\u5316<\/td>\n<td>\u65e0<\/td>\n<td>\u9700\u53e6\u9009\u914d<\/td>\n<td>PE\u6a21\u5757<\/td>\n<\/tr>\n<tr>\n<td>\u540a\u9876\u8981\u6c42<\/td>\n<td>\u7ea635cm<\/td>\n<td>\u5c40\u90e8\u8fdb\u6df1600mm<\/td>\n<td>\u540c\u5de6<\/td>\n<\/tr>\n<tr>\n<td>\u521d\u6295\u6210\u672c<\/td>\n<td>\u4f4e<\/td>\n<td>\u9ad8<\/td>\n<td>\u66f4\u9ad8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"lm-h2\">\u6309\u4ec0\u4e48\u987a\u5e8f\u9009\uff1a\u56db\u6b65\u5b9a\u672b\u7aef<\/h2>\n<ul>\n<li><b>\u7b2c\u4e00\u6b65\u5b9a\u7cfb\u7edf<\/b>\uff1a\u6c1f\u7cfb\u7edf\u8d70\u98ce\u76d8\uff0c\u8fd8\u662f\u6c34\u7cfb\u7edf\uff08\u4e24\u8054\u4f9b\uff09\u8d70\u98ce\u76d8\u52a0\u5730\u6696\uff1b<\/li>\n<li><b>\u7b2c\u4e8c\u6b65\u7b97\u6863\u4f4d<\/b>\uff1a\u6309\u623f\u95f4\u8d1f\u8377\u3001\u671d\u5411\u3001\u5c42\u9ad8\u548c\u540c\u5f00\u7387\u7b97\uff0c34\u5230119\u516d\u6863\u5bf9\u53f7\u5165\u5ea7\uff0c\u4e0d\u76f2\u76ee\u6c42\u5927\uff1b<\/li>\n<li><b>\u7b2c\u4e09\u6b65\u5b9a\u5c42\u6b21<\/b>\uff1a\u9884\u7b97\u7d27\u3001\u975e\u957f\u671f\u4f4f\u53ef\u8003\u8651\u534a\u5305\u5f0f\uff1b\u5bb6\u7528\u957f\u671f\u4f4f\u4f18\u5148\u5168\u76f4\u6d41\u53d8\u9891\uff1b\u5bf9\u7532\u919b\u548cPM2.5\u654f\u611f\u518d\u52a0PE\u51c0\u5316\uff1b<\/li>\n<li><b>\u7b2c\u56db\u6b65\u6838\u5b89\u88c5<\/b>\uff1a\u540a\u9876\u9ad8\u5ea6\u591f\u4e0d\u591f\u3001\u63a5\u7ba1\u65b9\u5411\u3001\u51b7\u51dd\u6c34\u600e\u4e48\u6392\u3001\u6709\u6ca1\u6709\u63d0\u5347\u6cf5\u548c\u6d6e\u5b50\u5f00\u5173\u3002<\/li>\n<\/ul>\n<p>\u672b\u7aef\u9009\u5bf9\uff0c\u4e3b\u673a\u7684\u80fd\u529b\u624d\u80fd\u771f\u6b63\u843d\u5730\u5230\u623f\u95f4\u3002\u98ce\u76d8\u770b\u7740\u5c0f\uff0c\u5374\u76f4\u63a5\u51b3\u5b9a\u9759\u97f3\u3001\u51dd\u9732\u548c\u8212\u9002\u5ea6\u2014\u2014\u8fd9\u4e00\u6b65\u7701\u4e0d\u5f97\u3002<\/p>\n<h2 class=\"lm-h2\">\u5e38\u89c1\u95ee\u7b54<\/h2>\n<h3>\u95ee\uff1a\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4e3a\u4ec0\u4e48\u4ef7\u683c\u80fd\u5dee\u51fa\u4e00\u622a\uff1f<\/h3>\n<p>\u7b54\uff1a\u5dee\u5728\u7ed3\u6784\u5c42\u6b21\uff0c\u4e0d\u5728\"\u80fd\u4e0d\u80fd\u51fa\u98ce\"\u3002\u6700\u4fbf\u5b9c\u7684\u534a\u5305\u5f0f\u662f\u5de5\u7a0b\u673a\uff1a\u63a5\u6c34\u76d8\u5916\u7f6e\u3001\u8bbe\u5907\u6ca1\u4fdd\u6e29\u68c9\u3001\u4ea4\u6d41\u5b9a\u9891\u7535\u673a\u3001\u9760\u91cd\u529b\u81ea\u7136\u6392\u6c34\uff1b\u5bb6\u7528\u4e3b\u529b\u7684\u5168\u76f4\u6d41\u53d8\u9891\u98ce\u76d8\u662f\u5185\u7f6e\u63a5\u6c34\u76d8\u3001\u6574\u4f53\u4fdd\u6e29\u3001\u76f4\u6d41\u65e0\u5237\u7535\u673a\u3001\u6807\u914d\u63d0\u5347\u6cf5\u548c\u6d6e\u5b50\u5f00\u5173\u3002\u540c\u6837\u662f\u98ce\u76d8\uff0c\u524d\u8005\u88c5\u5b8c\u5bb9\u6613\u51dd\u9732\u3001\u6253\u6e7f\u540a\u9876\u3001\u566a\u97f3\u9ad8\uff0c\u540e\u8005\u628a\u8fd9\u4e9b\u95ee\u9898\u5728\u51fa\u5382\u5c31\u89e3\u51b3\u4e86\u3002\u5dee\u4ef7\u4e70\u7684\u662f\u7ed3\u6784\u3001\u9759\u97f3\u548c\u540e\u671f\u7701\u5fc3\uff0c\u4e0d\u662f\u5671\u5934\u3002<\/p>\n<h3>\u95ee\uff1a\u4ec0\u4e48\u662f\u534a\u5305\u5f0f\u98ce\u76d8\uff1f\u5b83\u548c\u5bb6\u7528\u98ce\u76d8\u7684\u5206\u6c34\u5cad\u5728\u54ea\uff1f<\/h3>\n<p>\u7b54\uff1a\u534a\u5305\u5f0f\u6307\u7684\u662f\u63a5\u6c34\u76d8\u5916\u7f6e\u3001\u673a\u8eab\u6ca1\u6709\u4fdd\u6e29\u68c9\u7684\u5de5\u7a0b\u673a\u98ce\u76d8\uff0c\u5e38\u89c1\u4e8e\u4f4e\u4ef7\u6216\u5546\u7528\u9879\u76ee\u3002\u5206\u6c34\u5cad\u5c31\u4e24\u6761\uff1a\u4e00\u770b\u6709\u6ca1\u6709\u4fdd\u6e29\u68c9\u2014\u2014\u6ca1\u6709\u7684\u8bdd\uff0c\u673a\u7ec4\u8fd0\u884c\u540e\u51b7\u8868\u9762\u5bb9\u6613\u51dd\u9732\uff0c\u8f7b\u5219\u6253\u6e7f\u5929\u82b1\u677f\u3001\u7834\u574f\u88c5\u4fee\uff0c\u91cd\u5219\u8981\u62c6\u9876\u7ef4\u4fee\uff1b\u4e8c\u770b\u6392\u6c34\u65b9\u5f0f\u2014\u2014\u534a\u5305\u5f0f\u591a\u9760\u91cd\u529b\u81ea\u7136\u5761\u5ea6\u6392\u6c34\uff0c\u4e0d\u914d\u63d0\u5347\u6cf5\uff0c\u76d8\u91cc\u957f\u671f\u5b58\u6c34\u79ef\u7070\uff0c\u5bb9\u6613\u6ecb\u751f\u7ec6\u83cc\u3001\u4ea7\u751f\u9709\u83cc\u3002\u5bb6\u7528\u73af\u5883\u5bf9\u9759\u97f3\u548c\u540a\u9876\u89c2\u611f\u8981\u6c42\u9ad8\uff0c\u901a\u5e38\u4e0d\u9009\u8fd9\u4e00\u7c7b\u3002<\/p>\n<h3>\u95ee\uff1a\u65e5\u7acb\u96f6\u8d8a\u5168\u76f4\u6d41\u53d8\u9891\u98ce\u76d8\u6709\u54ea\u4e9b\u6838\u5fc3\u7279\u70b9\uff1f<\/h3>\n<p>\u7b54\uff1a\u6309\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\uff0c\u4e03\u9879\u6700\u503c\u5f97\u5173\u6ce8\uff1a\u4e00\u662f192mm\u7ea4\u8584\u673a\u8eab\uff0c\u8fdb\u6df1447mm\u3001\u5c40\u90e8\u540a\u9876\u8fdb\u6df1\u4ec5\u9700600mm\uff0c\u53ef\u4e0e\u8863\u67dc\u7acb\u9762\u9f50\u5e73\uff1b\u4e8c\u662f\u5168\u7cfb\u6807\u914d\u56de\u98ce\u7bb1\uff0c\u8717\u58f3\u548c\u53f6\u8f6e\u7528\u8f7b\u578b\u6750\u8d28\u3001\u566a\u97f3\u4f4e\uff1b\u4e09\u662f\u76f4\u6d41\u65e0\u5237\u5851\u5c01\u7535\u673a\uff0c\u4e09\u6863\u9759\u538b18\u7ea7\u8c03\u901f\u3001\u9632\u6c34\u9632\u5c18\u3001\u65e0\u5f02\u5e38\u7535\u78c1\u58f0\uff1b\u56db\u662f\u56de\u98ce\u3001\u76d8\u7ba1\u3001\u7ebf\u63a7\u5668\u4e09\u53ea\u4f20\u611f\u5668\u4e09\u4f4d\u4e00\u4f53\u7acb\u4f53\u611f\u6e29\uff1b\u4e94\u662f\u6807\u914d1200mm\u9ad8\u626c\u7a0b\u6c34\u6cf5\u3001\u6d6e\u5b50\u5f00\u5173\u8054\u52a8\u9632\u6ea2\u6c34\uff1b\u516d\u662fEPP\u53d1\u6ce1\u52a0XPE\u5916\u4fa7\u4fdd\u6e29\u3001\u4fa7\u677f\u51b7\u6865\u5904\u7406\uff0c\u4ece\u6e90\u5934\u9632\u51dd\u9732\uff1b\u4e03\u662f\u51fa\u98ce\u9759\u538b0\/12\/30Pa\u53ef\u8c03\u3001\u5de6\u53f3\u63a5\u7ba1\u53ef\u9009\u3002\u6700\u4f4e\u53ef\u5b9e\u73b020\u5206\u8d1d\u9759\u97f3\u3002\u53c2\u6570\u8868\u91cc\u76840\/12\/30Pa\u662f\u51fa\u98ce\u9759\u538b\u6863\u4f4d\uff0c\u9759\u538b\u6307\u514b\u670d\u98ce\u7ba1\u963b\u529b\u7684\u80fd\u529b\uff1a\u77ed\u76f4\u51fa\u98ce\u53e3\u75280\u523012Pa\u5c31\u591f\uff0c\u63a5\u957f\u98ce\u7ba1\u3001\u591a\u4e2a\u98ce\u53e3\u624d\u9700\u898130Pa\u9ad8\u9759\u538b\u6863\uff0c\u666e\u901a\u5bb6\u7528\u591a\u6570\u573a\u666f\u7528\u4e0d\u5230\u9ad8\u9759\u538b\u3002<\/p>\n<h3>\u95ee\uff1a\u96f6\u8d8a\u98ce\u76d8\u6709\u54ea\u51e0\u4e2a\u5bb9\u91cf\u6863\uff1f\u5236\u51b7\u5236\u70ed\u80fd\u529b\u5927\u6982\u4ec0\u4e48\u8303\u56f4\uff1f<\/h3>\n<p>\u7b54\uff1a\u96f6\u8d8a\u6807\u51c6\u578b\u8d85\u8584DC\u98ce\u76d8\u5171\u516d\u6863\uff1a34\u300151\u300168\u300185\u3001102\u3001119\u3002\u6309\u6837\u518c\u8d85\u9ad8\u901f\u6863\u53c2\u6570\uff0c\u98ce\u91cf\u4ece340\u52301190\u7acb\u65b9\u7c73\u6bcf\u5c0f\u65f6\uff1b\u989d\u5b9a\u5236\u51b7\u5168\u70ed\u51b7\u91cf\u4ece2500W\u52306810W\uff1b\u4f9b\u70ed\u91cf\u630960\u2103\u70ed\u6c34\u4ece3800W\u523010950W\uff0c\u630945\u2103\u70ed\u6c34\u4ece2370W\u52306700W\u3002\u9009\u578b\u4e0d\u662f\u6863\u4f4d\u8d8a\u5927\u8d8a\u597d\uff0c\u8981\u6309\u623f\u95f4\u8d1f\u8377\u3001\u671d\u5411\u3001\u5c42\u9ad8\u548c\u540c\u5f00\u7387\u7b97\u51c6\uff0c\u6863\u4f4d\u914d\u5927\u4e86\u540c\u6837\u6709\u566a\u97f3\u548c\u6210\u672c\u6d6a\u8d39\u3002<\/p>\n<h3>\u95ee\uff1a\u5f15\u7528\u98ce\u76d8\u53c2\u6570\u65f6\u9700\u8981\u5e26\u54ea\u4e9b\u5de5\u51b5\u8bf4\u660e\uff1f<\/h3>\n<p>\u7b54\uff1a\u4e00\u5b9a\u8981\u5e26\uff0c\u5426\u5219\u5bb9\u6613\u88ab\u8d28\u7591\u3002\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\u660e\u786e\u5199\u4e86\u56db\u6761\uff1a\u4e00\u662f\u4f9b\u51b7\u91cf\u3001\u4f9b\u70ed\u91cf\u3001\u6c34\u6d41\u91cf\u3001\u6c34\u963b\u529b\u5747\u4e3a\u8d85\u9ad8\u901f\u6863\u53c2\u6570\uff1b\u4e8c\u662f\u5236\u51b7\u6309\u8fdb\u98ce\u5e72\u6e7f\u7403\u6e29\u5ea627\/19.5\u2103\u3001\u51b7\u51bb\u6c34\u8fdb\u51fa\u6c347\/12\u2103\uff0c\u5236\u70ed\u6309\u8fdb\u98ce\u5e72\u740321\u2103\u3001\u70ed\u6c34\u8fdb\u6c3460\u2103\uff1b\u4e09\u662f\u989d\u5b9a\u98ce\u91cf\u662f\u5728\u6807\u51c6\u7a7a\u6c14\u72b6\u6001\u3001\u76d8\u7ba1\u5e72\u5de5\u51b5\uff08\u5e72\u740320\u2103\uff09\u4e0b\u6d4b\u7684\uff1b\u56db\u662f\u566a\u58f0\u4e3a\u534a\u6d88\u58f0\u5ba4\u6d4b\u8bd5\uff08\u6309GB\/T 19232-2019\uff09\u3002\u8131\u79bb\u5de5\u51b5\u8c08\"\u591a\u5c11\u74e6\u3001\u591a\u5c11\u5206\u8d1d\"\u6ca1\u6709\u610f\u4e49\u3002<\/p>\n<h3>\u95ee\uff1a\u5e26PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u7684\u98ce\u76d8\u80fd\u51c0\u5316\u4ec0\u4e48\uff1f\u6570\u636e\u53ef\u4fe1\u5417\uff1f<\/h3>\n<p>\u7b54\uff1aPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u7528\u8d1f\u79bb\u5b50\u6280\u672f\uff1a\u91ca\u653e\u9ad8\u6d3b\u6027\u5c0f\u7c92\u5f84\u8d1f\u79bb\u5b50\uff0c\u8ba9PM2.5\u9897\u7c92\u51dd\u805a\u6c89\u964d\u3001\u8ba9\u7ec6\u83cc\u7ed3\u6784\u6539\u53d8\u5931\u6d3b\uff0c\u8fd8\u80fd\u964d\u89e3\u7532\u919b\u3001\u9664\u5f02\u5473\u3002\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\u6807\u6ce8\uff1aPM2.5\u9897\u7c92\u7269\u51c0\u5316\u6548\u738794.46%\uff0830\u7acb\u65b9\u7c73\/2\u5c0f\u65f6\uff09\u3001\u9664\u786b\u5316\u6c2279.20%\uff0830\u7acb\u65b9\u7c73\/24\u5c0f\u65f6\uff09\u3001\u5927\u80a0\u6746\u83cc\u51c0\u5316\u738799.16%\uff0830\u7acb\u65b9\u7c73\/2\u5c0f\u65f6\uff09\u3001\u7532\u578b\u6d41\u611f\u75c5\u6bd2H3N2\u51c0\u5316\u738799.65%\uff0830\u7acb\u65b9\u7c73\/1\u5c0f\u65f6\uff09\uff0c\u8bd5\u9a8c\u6570\u636e\u6ce8\u660e\u6765\u81ea\u5e7f\u4e1c\u7701\u5fae\u751f\u7269\u5206\u6790\u68c0\u6d4b\u4e2d\u5fc3\u3002\u8fd9\u4e9b\u662f\u7279\u5b9a\u5bb9\u79ef\u548c\u65f6\u957f\u4e0b\u7684\u5b9e\u9a8c\u5ba4\u6570\u636e\uff0c\u5bb6\u4e2d\u5b9e\u9645\u6548\u679c\u53d7\u623f\u95f4\u5927\u5c0f\u3001\u6c14\u5bc6\u6027\u548c\u8fd0\u884c\u65f6\u95f4\u5f71\u54cd\uff0c\u4e0d\u80fd\u5f53\u4fdd\u8bc1\u503c\u3002\u8fd8\u8981\u8bf4\u6e05\uff1a\u8d1f\u79bb\u5b50PE\u6a21\u5757\u505a\u7684\u662f\u5c40\u90e8\u8f85\u52a9\u51c0\u5316\uff0c\u4e0d\u80fd\u66ff\u4ee3\u5b8c\u6574\u65b0\u98ce\u7cfb\u7edf\uff0c\u89e3\u51b3\u4e0d\u4e86\u5168\u5c4b\u4e8c\u6c27\u5316\u78b3\u6d53\u5ea6\u3001VOC\u7684\u6301\u7eed\u7f6e\u6362\u3002<\/p>\n<h3>\u95ee\uff1aPE\u6a21\u5757\u662f\u6807\u914d\u8fd8\u662f\u9009\u914d\uff1f\u5b83\u548c\u6ee4\u7f51\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/h3>\n<p>\u7b54\uff1a\u4e24\u8005\u8981\u5206\u6e05\u3002\u6309\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\u539f\u6587\uff0cPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u4e3a\u9009\u914d\u4ef6\uff0c\u51c0\u5316\u578b\u5ba4\u5185\u673a\u624d\u662f\u6807\u914d\u2014\u2014\u6307\u7684\u662f\u4e0d\u540c\u673a\u578b\uff0c\u4e0d\u662f\u81ea\u76f8\u77db\u76fe\u3002\u5b83\u548c\u6ee4\u7f51\u6700\u5927\u7684\u533a\u522b\u5728\u7ef4\u62a4\uff1a\u6d3b\u6027\u70ad\u6ee4\u7f511\u52302\u5e74\u66f4\u6362\u3001\u6bcf3\u52306\u4e2a\u6708\u6e05\u626b\uff0cPM2.5\u6ee4\u7f513\u4e2a\u6708\u6e05\u626b\u30016\u4e2a\u6708\u66f4\u6362\u4e14\u4e0d\u80fd\u6c34\u6d17\uff1b\u800cPE\u6a21\u5757\u65e0\u9700\u6e05\u6d17\u548c\u66f4\u6362\uff0c\u957f\u6548\u4f7f\u7528\u66f4\u4fbf\u6377\u3002\u82e5\u5bb6\u91cc\u5bf9\u7532\u919b\u3001PM2.5\u3001\u5f02\u5473\u654f\u611f\uff0c\u53ef\u5728\u9009\u914d\u65f6\u52a0PE\u6a21\u5757\u6216\u5bf9\u5e94\u6ee4\u7f51\u7ec4\u4ef6\u3002<\/p>\n<h3>\u95ee\uff1a\u98ce\u76d8\u9759\u97f3\u5230\u5e95\u80fd\u5230\u591a\u5c11\u5206\u8d1d\uff1f\u7f51\u4f20\u768419.5\u662f\u771f\u7684\u5417\uff1f<\/h3>\n<p>\u7b54\uff1a\u6309\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\uff0c\u76f4\u6d41\u65e0\u5237\u5851\u5c01\u7535\u673a\u914d\u8f7b\u578b\u8717\u58f3\u53f6\u8f6e\uff0c\u53ef\u5b9e\u73b0\u6700\u4f4e20\u5206\u8d1d\u9759\u97f3\uff1b\u516d\u6863\u53c2\u6570\u8868\u91cc34\u578b\u5fae\u98ce\u6863\u4e3a20dB(A)\uff0c\u5bb9\u91cf\u8d8a\u5927\u566a\u97f3\u76f8\u5e94\u5347\u9ad8\u3002\u7f51\u4e0a\u6d41\u4f20\u768419.5\u8fd9\u4e2a\u6570\uff0c\u5728\u6837\u518c\u53c2\u6570\u91cc\u662f\u5236\u51b7\u8fdb\u98ce\u7684\u6e7f\u7403\u6e29\u5ea6\uff0827\/19.5\u2103\uff09\uff0c\u4e0d\u662f\u566a\u97f3\u503c\uff0c\u522b\u628a\u5de5\u51b5\u53c2\u6570\u5f53\u6210\u9759\u97f3\u6307\u6807\u3002\u770b\u9759\u97f3\u8981\u8ba4\u51c6\"\u5206\u8d1ddB(A)\"\u548c\u5bf9\u5e94\u6863\u4f4d\u3002<\/p>\n<h3>\u95ee\uff1a\u63d0\u5347\u6cf5\u626c\u7a0b1200mm\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u548c1125mm\u77db\u76fe\u5417\uff1f<\/h3>\n<p>\u7b54\uff1a\u4e0d\u77db\u76fe\uff0c\u662f\u4e24\u6b3e\u4e0d\u540c\u4ea7\u54c1\u3002\u65e5\u7acb\u96f6\u8d8a\u8d85\u8584DC\u98ce\u76d8\u6807\u914d\u7684\u662f1200mm\u9ad8\u626c\u7a0b\u6c34\u6cf5\uff0c\u914d\u6d6e\u5b50\u5f00\u5173\u4e0e\u63a7\u5236\u8054\u52a8\u9632\u6ea2\u6c34\uff1b\u53e6\u6709\u5361\u5f0f\u98ce\u76d8\u6807\u6ce81125mm\uff0c\u5c5e\u4e8e\u4e0d\u540c\u4ea7\u54c1\u7ebf\u7684\u53c2\u6570\u3002\u8865\u4e00\u53e5\u8fb9\u754c\uff1a\u6d6e\u5b50\u5f00\u5173\u662f\u6ea2\u6c34\u4fdd\u62a4\uff0c\u4e0d\u662f\u9632\u6b62\u51b7\u51dd\u6c34\u7ba1\u5835\u585e\uff0c\u6392\u6c34\u7ba1\u4ecd\u9700\u5b9a\u671f\u6e05\u7406\u3002\u63d0\u5347\u6cf5\u7684\u4f5c\u7528\u662f\u8ba9\u51b7\u51dd\u6c34\u5728\u540a\u9876\u9ad8\u5ea6\u53d7\u9650\u3001 \u91cd\u529b\u6392\u6c34\u5761\u5ea6\u4e0d\u591f\u65f6\u4e5f\u80fd\u987a\u5229\u6392\u51fa\uff0c\u626c\u7a0b\u8d8a\u9ad8\u3001\u53ef\u514b\u670d\u7684\u6392\u6c34\u963b\u529b\u8d8a\u5927\u3002\u770b\u53c2\u6570\u8981\u8fde\u540c\u4ea7\u54c1\u578b\u53f7\u4e00\u8d77\u770b\uff0c\u522b\u628a\u4e0d\u540c\u4ea7\u54c1\u7684\u6570\u5b57\u653e\u5230\u4e00\u53f0\u673a\u5668\u4e0a\u6bd4\u8f83\u3002<\/p>\n<h3>\u95ee\uff1a\u5bb6\u91cc\u88c5\u98ce\u76d8\uff0c\u8be5\u6309\u4ec0\u4e48\u987a\u5e8f\u9009\uff1f<\/h3>\n<p>\u7b54\uff1a\u5148\u5b9a\u8def\u7ebf\u518d\u5b9a\u672b\u7aef\u3002\u7b2c\u4e00\u6b65\u770b\u7cfb\u7edf\uff1a\u662f\u6c1f\u7cfb\u7edf\u8d70\u98ce\u76d8\uff0c\u8fd8\u662f\u6c34\u7cfb\u7edf\uff08\u4e24\u8054\u4f9b\uff09\u8d70\u98ce\u76d8\u52a0\u5730\u6696\uff1b\u7b2c\u4e8c\u6b65\u6309\u623f\u95f4\u8d1f\u8377\u7b97\u6863\u4f4d\uff0c34\u5230119\u516d\u6863\u5bf9\u5e94\u4e0d\u540c\u9762\u79ef\u548c\u671d\u5411\uff1b\u7b2c\u4e09\u6b65\u5b9a\u5c42\u6b21\uff1a\u9884\u7b97\u7d27\u3001\u975e\u957f\u671f\u5c45\u4f4f\u53ef\u9009\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\uff0c\u5bb6\u7528\u957f\u671f\u4f4f\u4f18\u5148\u5168\u76f4\u6d41\u53d8\u9891\uff0c\u5bf9\u7532\u919b\u548cPM2.5\u654f\u611f\u518d\u52a0PE\u51c0\u5316\u6a21\u5757\uff1b\u7b2c\u56db\u6b65\u6838\u5b89\u88c5\u6761\u4ef6\u2014\u2014\u540a\u9876\u9ad8\u5ea6\u3001\u63a5\u7ba1\u65b9\u5411\u3001\u51b7\u51dd\u6c34\u600e\u4e48\u6392\u3001\u6709\u6ca1\u6709\u63d0\u5347\u6cf5\u3002\u672b\u7aef\u9009\u5bf9\u4e86\uff0c\u4e3b\u673a\u80fd\u529b\u624d\u80fd\u771f\u6b63\u843d\u5730\u3002<\/p>\n<h2 class=\"lm-h2\">\u76f8\u5173\u9875\u9762<\/h2>\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20790\">\u771f\u4e94\u6052\u600e\u4e48\u5224\u65ad\uff1f\u4e94\u9879\u8fbe\u6807\u662f\u7ed3\u679c\uff0c\u8f90\u5c04\u677f\u3001\u5168\u7a7a\u6c14\u3001\u98ce\u76d8\u65b0\u98ce\u90fd\u53ea\u662f\u5f62\u5f0f<\/a> \u2014\u2014 \u4e94\u6052\u662f\u7ed3\u679c\u6307\u6807\uff0c\u672b\u7aef\u53ea\u662f\u5b9e\u73b0\u5f62\u5f0f<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12292\">\u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03\u600e\u4e48\u9009\uff5c\u6c1f\u673a\u9009\u578b\u3001\u5b89\u88c5\u9a8c\u6536\u4e0e\u552e\u540e\u5168\u89e3<\/a> \u2014\u2014 \u98ce\u76d8\u6240\u5728\u7684\u6c1f\u7cfb\u7edf\u5b8c\u6574\u9009\u578b\u4f9d\u636e<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a> \u2014\u2014 \u6c34\u7cfb\u7edf\u98ce\u76d8\u52a0\u5730\u6696\u7684\u4e24\u6761\u8def\u7ebf<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=2543\">\u65e5\u7acb\u00a0VAM \u5c0a\u777f\u522b\u5885\u7cfb\u5217\u4e2d\u592e\u7a7a\u8c03<\/a> \u2014\u2014 \u96f6\u8d8a\u98ce\u76d8\u914d\u5957\u7684\u4e3b\u673a\u53c2\u6570\u793a\u4f8b<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20650\">\u7a7a\u8c03\u94ed\u724c\u4e0a\u7684COP\u3001APF\u3001IPLV\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u4e3a\u4ec0\u4e48\u5230\u624b\u6548\u679c\u5dee\u4e00\u622a<\/a> \u2014\u2014 \u540d\u4e49\u5de5\u51b5\u4e0e\u771f\u5b9e\u5de5\u51b5\u7684\u5dee\u522b<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20717\">\u6210\u90fd\u51ac\u5b63\u7a7a\u8c03\u5236\u70ed\u597d\u4e0d\u597d\uff0c\u5173\u952e\u770b\u8865\u6c14\u589e\u7113\uff1a\u4e0d\u53ea\u662f\u66f4\u6696\uff0c\u8fd8\u66f4\u7701\u7535<\/a> \u2014\u2014 \u51ac\u5b63\u4f4e\u6e29\u5236\u70ed\u7684\u4e3b\u673a\u6280\u672f<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=7862\">\u6210\u90fd\u6210\u534e\u8a89\u6d6a\u4e1c\u671bB\u533a\uff5c\u65e5\u7acb\u6c34\u5885\u9002\u7a7a\u8c03\u5730\u6696\u4e00\u4f53\u6848\u4f8b<\/a> \u2014\u2014 \u96f6\u8d8a\u98ce\u76d8\u5b9e\u9645\u843d\u5730\u6848\u4f8b<\/li>\n<\/ul>\n<h2 class=\"lm-h2\">\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p>\u4e24\u5bb6\u5e97\u90fd\u5728\u5bcc\u68ee\u7f8e\u3002\u4e0a\u95e8\u52d8\u6d4b\u4e0d\u6536\u8d39\uff0c\u51fa\u4e66\u9762\u65b9\u6848\u2014\u2014\u98ce\u76d8\u6863\u4f4d\u3001\u672b\u7aef\u5e03\u5c40\u3001\u51b7\u51dd\u6c34\u600e\u4e48\u6392\u90fd\u9010\u9879\u5217\u51fa\u6765\uff0c\u62ff\u7740\u53bb\u6bd4\u4ef7\u4e5f\u884c\u3002\u60f3\u5148\u7535\u8bdd\u804a\uff0c\u4e24\u4e2a\u95e8\u5e97\u7684\u8d1f\u8d23\u4eba\u76f4\u63a5\u5bf9\u63a5\uff08\u5fae\u4fe1\u540c\u53f7\uff09\uff1a<\/p>\n<ul>\n<li><strong>\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/strong>\uff08\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B \/ A348\uff09\uff5c \u70ed\u7ebf <a href=\"tel:02886131795\">028-86131795<\/a> \uff5c \u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a><\/li>\n<li><strong>\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/strong>\uff08\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135\uff09\uff5c \u70ed\u7ebf <a href=\"tel:02865272586\">028-65272586<\/a> \uff5c \u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a><\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"@id\": \"https:\/\/longmai-nt.com\/?page_id=20725#faq\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4e3a\u4ec0\u4e48\u4ef7\u683c\u80fd\u5dee\u51fa\u4e00\u622a\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5dee\u5728\u7ed3\u6784\u5c42\u6b21\uff0c\u4e0d\u5728\\\"\u80fd\u4e0d\u80fd\u51fa\u98ce\\\"\u3002\u6700\u4fbf\u5b9c\u7684\u534a\u5305\u5f0f\u662f\u5de5\u7a0b\u673a\uff1a\u63a5\u6c34\u76d8\u5916\u7f6e\u3001\u8bbe\u5907\u6ca1\u4fdd\u6e29\u68c9\u3001\u4ea4\u6d41\u5b9a\u9891\u7535\u673a\u3001\u9760\u91cd\u529b\u81ea\u7136\u6392\u6c34\uff1b\u5bb6\u7528\u4e3b\u529b\u7684\u5168\u76f4\u6d41\u53d8\u9891\u98ce\u76d8\u662f\u5185\u7f6e\u63a5\u6c34\u76d8\u3001\u6574\u4f53\u4fdd\u6e29\u3001\u76f4\u6d41\u65e0\u5237\u7535\u673a\u3001\u6807\u914d\u63d0\u5347\u6cf5\u548c\u6d6e\u5b50\u5f00\u5173\u3002\u540c\u6837\u662f\u98ce\u76d8\uff0c\u524d\u8005\u88c5\u5b8c\u5bb9\u6613\u51dd\u9732\u3001\u6253\u6e7f\u540a\u9876\u3001\u566a\u97f3\u9ad8\uff0c\u540e\u8005\u628a\u8fd9\u4e9b\u95ee\u9898\u5728\u51fa\u5382\u5c31\u89e3\u51b3\u4e86\u3002\u5dee\u4ef7\u4e70\u7684\u662f\u7ed3\u6784\u3001\u9759\u97f3\u548c\u540e\u671f\u7701\u5fc3\uff0c\u4e0d\u662f\u5671\u5934\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u4ec0\u4e48\u662f\u534a\u5305\u5f0f\u98ce\u76d8\uff1f\u5b83\u548c\u5bb6\u7528\u98ce\u76d8\u7684\u5206\u6c34\u5cad\u5728\u54ea\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u534a\u5305\u5f0f\u6307\u7684\u662f\u63a5\u6c34\u76d8\u5916\u7f6e\u3001\u673a\u8eab\u6ca1\u6709\u4fdd\u6e29\u68c9\u7684\u5de5\u7a0b\u673a\u98ce\u76d8\uff0c\u5e38\u89c1\u4e8e\u4f4e\u4ef7\u6216\u5546\u7528\u9879\u76ee\u3002\u5206\u6c34\u5cad\u5c31\u4e24\u6761\uff1a\u4e00\u770b\u6709\u6ca1\u6709\u4fdd\u6e29\u68c9\u2014\u2014\u6ca1\u6709\u7684\u8bdd\uff0c\u673a\u7ec4\u8fd0\u884c\u540e\u51b7\u8868\u9762\u5bb9\u6613\u51dd\u9732\uff0c\u8f7b\u5219\u6253\u6e7f\u5929\u82b1\u677f\u3001\u7834\u574f\u88c5\u4fee\uff0c\u91cd\u5219\u8981\u62c6\u9876\u7ef4\u4fee\uff1b\u4e8c\u770b\u6392\u6c34\u65b9\u5f0f\u2014\u2014\u534a\u5305\u5f0f\u591a\u9760\u91cd\u529b\u81ea\u7136\u5761\u5ea6\u6392\u6c34\uff0c\u4e0d\u914d\u63d0\u5347\u6cf5\uff0c\u76d8\u91cc\u957f\u671f\u5b58\u6c34\u79ef\u7070\uff0c\u5bb9\u6613\u6ecb\u751f\u7ec6\u83cc\u3001\u4ea7\u751f\u9709\u83cc\u3002\u5bb6\u7528\u73af\u5883\u5bf9\u9759\u97f3\u548c\u540a\u9876\u89c2\u611f\u8981\u6c42\u9ad8\uff0c\u901a\u5e38\u4e0d\u9009\u8fd9\u4e00\u7c7b\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u65e5\u7acb\u96f6\u8d8a\u5168\u76f4\u6d41\u53d8\u9891\u98ce\u76d8\u6709\u54ea\u4e9b\u6838\u5fc3\u7279\u70b9\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6309\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\uff0c\u4e03\u9879\u6700\u503c\u5f97\u5173\u6ce8\uff1a\u4e00\u662f192mm\u7ea4\u8584\u673a\u8eab\uff0c\u8fdb\u6df1447mm\u3001\u5c40\u90e8\u540a\u9876\u8fdb\u6df1\u4ec5\u9700600mm\uff0c\u53ef\u4e0e\u8863\u67dc\u7acb\u9762\u9f50\u5e73\uff1b\u4e8c\u662f\u5168\u7cfb\u6807\u914d\u56de\u98ce\u7bb1\uff0c\u8717\u58f3\u548c\u53f6\u8f6e\u7528\u8f7b\u578b\u6750\u8d28\u3001\u566a\u97f3\u4f4e\uff1b\u4e09\u662f\u76f4\u6d41\u65e0\u5237\u5851\u5c01\u7535\u673a\uff0c\u4e09\u6863\u9759\u538b18\u7ea7\u8c03\u901f\u3001\u9632\u6c34\u9632\u5c18\u3001\u65e0\u5f02\u5e38\u7535\u78c1\u58f0\uff1b\u56db\u662f\u56de\u98ce\u3001\u76d8\u7ba1\u3001\u7ebf\u63a7\u5668\u4e09\u53ea\u4f20\u611f\u5668\u4e09\u4f4d\u4e00\u4f53\u7acb\u4f53\u611f\u6e29\uff1b\u4e94\u662f\u6807\u914d1200mm\u9ad8\u626c\u7a0b\u6c34\u6cf5\u3001\u6d6e\u5b50\u5f00\u5173\u8054\u52a8\u9632\u6ea2\u6c34\uff1b\u516d\u662fEPP\u53d1\u6ce1\u52a0XPE\u5916\u4fa7\u4fdd\u6e29\u3001\u4fa7\u677f\u51b7\u6865\u5904\u7406\uff0c\u4ece\u6e90\u5934\u9632\u51dd\u9732\uff1b\u4e03\u662f\u51fa\u98ce\u9759\u538b0\/12\/30Pa\u53ef\u8c03\u3001\u5de6\u53f3\u63a5\u7ba1\u53ef\u9009\u3002\u6700\u4f4e\u53ef\u5b9e\u73b020\u5206\u8d1d\u9759\u97f3\u3002\u53c2\u6570\u8868\u91cc\u76840\/12\/30Pa\u662f\u51fa\u98ce\u9759\u538b\u6863\u4f4d\uff0c\u9759\u538b\u6307\u514b\u670d\u98ce\u7ba1\u963b\u529b\u7684\u80fd\u529b\uff1a\u77ed\u76f4\u51fa\u98ce\u53e3\u75280\u523012Pa\u5c31\u591f\uff0c\u63a5\u957f\u98ce\u7ba1\u3001\u591a\u4e2a\u98ce\u53e3\u624d\u9700\u898130Pa\u9ad8\u9759\u538b\u6863\uff0c\u666e\u901a\u5bb6\u7528\u591a\u6570\u573a\u666f\u7528\u4e0d\u5230\u9ad8\u9759\u538b\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u96f6\u8d8a\u98ce\u76d8\u6709\u54ea\u51e0\u4e2a\u5bb9\u91cf\u6863\uff1f\u5236\u51b7\u5236\u70ed\u80fd\u529b\u5927\u6982\u4ec0\u4e48\u8303\u56f4\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u96f6\u8d8a\u6807\u51c6\u578b\u8d85\u8584DC\u98ce\u76d8\u5171\u516d\u6863\uff1a34\u300151\u300168\u300185\u3001102\u3001119\u3002\u6309\u6837\u518c\u8d85\u9ad8\u901f\u6863\u53c2\u6570\uff0c\u98ce\u91cf\u4ece340\u52301190\u7acb\u65b9\u7c73\u6bcf\u5c0f\u65f6\uff1b\u989d\u5b9a\u5236\u51b7\u5168\u70ed\u51b7\u91cf\u4ece2500W\u52306810W\uff1b\u4f9b\u70ed\u91cf\u630960\u2103\u70ed\u6c34\u4ece3800W\u523010950W\uff0c\u630945\u2103\u70ed\u6c34\u4ece2370W\u52306700W\u3002\u9009\u578b\u4e0d\u662f\u6863\u4f4d\u8d8a\u5927\u8d8a\u597d\uff0c\u8981\u6309\u623f\u95f4\u8d1f\u8377\u3001\u671d\u5411\u3001\u5c42\u9ad8\u548c\u540c\u5f00\u7387\u7b97\u51c6\uff0c\u6863\u4f4d\u914d\u5927\u4e86\u540c\u6837\u6709\u566a\u97f3\u548c\u6210\u672c\u6d6a\u8d39\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5f15\u7528\u98ce\u76d8\u53c2\u6570\u65f6\u9700\u8981\u5e26\u54ea\u4e9b\u5de5\u51b5\u8bf4\u660e\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e00\u5b9a\u8981\u5e26\uff0c\u5426\u5219\u5bb9\u6613\u88ab\u8d28\u7591\u3002\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\u660e\u786e\u5199\u4e86\u56db\u6761\uff1a\u4e00\u662f\u4f9b\u51b7\u91cf\u3001\u4f9b\u70ed\u91cf\u3001\u6c34\u6d41\u91cf\u3001\u6c34\u963b\u529b\u5747\u4e3a\u8d85\u9ad8\u901f\u6863\u53c2\u6570\uff1b\u4e8c\u662f\u5236\u51b7\u6309\u8fdb\u98ce\u5e72\u6e7f\u7403\u6e29\u5ea627\/19.5\u2103\u3001\u51b7\u51bb\u6c34\u8fdb\u51fa\u6c347\/12\u2103\uff0c\u5236\u70ed\u6309\u8fdb\u98ce\u5e72\u740321\u2103\u3001\u70ed\u6c34\u8fdb\u6c3460\u2103\uff1b\u4e09\u662f\u989d\u5b9a\u98ce\u91cf\u662f\u5728\u6807\u51c6\u7a7a\u6c14\u72b6\u6001\u3001\u76d8\u7ba1\u5e72\u5de5\u51b5\uff08\u5e72\u740320\u2103\uff09\u4e0b\u6d4b\u7684\uff1b\u56db\u662f\u566a\u58f0\u4e3a\u534a\u6d88\u58f0\u5ba4\u6d4b\u8bd5\uff08\u6309GB\/T 19232-2019\uff09\u3002\u8131\u79bb\u5de5\u51b5\u8c08\\\"\u591a\u5c11\u74e6\u3001\u591a\u5c11\u5206\u8d1d\\\"\u6ca1\u6709\u610f\u4e49\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5e26PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u7684\u98ce\u76d8\u80fd\u51c0\u5316\u4ec0\u4e48\uff1f\u6570\u636e\u53ef\u4fe1\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"PE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u7528\u8d1f\u79bb\u5b50\u6280\u672f\uff1a\u91ca\u653e\u9ad8\u6d3b\u6027\u5c0f\u7c92\u5f84\u8d1f\u79bb\u5b50\uff0c\u8ba9PM2.5\u9897\u7c92\u51dd\u805a\u6c89\u964d\u3001\u8ba9\u7ec6\u83cc\u7ed3\u6784\u6539\u53d8\u5931\u6d3b\uff0c\u8fd8\u80fd\u964d\u89e3\u7532\u919b\u3001\u9664\u5f02\u5473\u3002\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\u6807\u6ce8\uff1aPM2.5\u9897\u7c92\u7269\u51c0\u5316\u6548\u738794.46%\uff0830\u7acb\u65b9\u7c73\/2\u5c0f\u65f6\uff09\u3001\u9664\u786b\u5316\u6c2279.20%\uff0830\u7acb\u65b9\u7c73\/24\u5c0f\u65f6\uff09\u3001\u5927\u80a0\u6746\u83cc\u51c0\u5316\u738799.16%\uff0830\u7acb\u65b9\u7c73\/2\u5c0f\u65f6\uff09\u3001\u7532\u578b\u6d41\u611f\u75c5\u6bd2H3N2\u51c0\u5316\u738799.65%\uff0830\u7acb\u65b9\u7c73\/1\u5c0f\u65f6\uff09\uff0c\u8bd5\u9a8c\u6570\u636e\u6ce8\u660e\u6765\u81ea\u5e7f\u4e1c\u7701\u5fae\u751f\u7269\u5206\u6790\u68c0\u6d4b\u4e2d\u5fc3\u3002\u8fd9\u4e9b\u662f\u7279\u5b9a\u5bb9\u79ef\u548c\u65f6\u957f\u4e0b\u7684\u5b9e\u9a8c\u5ba4\u6570\u636e\uff0c\u5bb6\u4e2d\u5b9e\u9645\u6548\u679c\u53d7\u623f\u95f4\u5927\u5c0f\u3001\u6c14\u5bc6\u6027\u548c\u8fd0\u884c\u65f6\u95f4\u5f71\u54cd\uff0c\u4e0d\u80fd\u5f53\u4fdd\u8bc1\u503c\u3002\u8fd8\u8981\u8bf4\u6e05\uff1a\u8d1f\u79bb\u5b50PE\u6a21\u5757\u505a\u7684\u662f\u5c40\u90e8\u8f85\u52a9\u51c0\u5316\uff0c\u4e0d\u80fd\u66ff\u4ee3\u5b8c\u6574\u65b0\u98ce\u7cfb\u7edf\uff0c\u89e3\u51b3\u4e0d\u4e86\u5168\u5c4b\u4e8c\u6c27\u5316\u78b3\u6d53\u5ea6\u3001VOC\u7684\u6301\u7eed\u7f6e\u6362\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"PE\u6a21\u5757\u662f\u6807\u914d\u8fd8\u662f\u9009\u914d\uff1f\u5b83\u548c\u6ee4\u7f51\u6709\u4ec0\u4e48\u533a\u522b\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e24\u8005\u8981\u5206\u6e05\u3002\u6309\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\u539f\u6587\uff0cPE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\u4e3a\u9009\u914d\u4ef6\uff0c\u51c0\u5316\u578b\u5ba4\u5185\u673a\u624d\u662f\u6807\u914d\u2014\u2014\u6307\u7684\u662f\u4e0d\u540c\u673a\u578b\uff0c\u4e0d\u662f\u81ea\u76f8\u77db\u76fe\u3002\u5b83\u548c\u6ee4\u7f51\u6700\u5927\u7684\u533a\u522b\u5728\u7ef4\u62a4\uff1a\u6d3b\u6027\u70ad\u6ee4\u7f511\u52302\u5e74\u66f4\u6362\u3001\u6bcf3\u52306\u4e2a\u6708\u6e05\u626b\uff0cPM2.5\u6ee4\u7f513\u4e2a\u6708\u6e05\u626b\u30016\u4e2a\u6708\u66f4\u6362\u4e14\u4e0d\u80fd\u6c34\u6d17\uff1b\u800cPE\u6a21\u5757\u65e0\u9700\u6e05\u6d17\u548c\u66f4\u6362\uff0c\u957f\u6548\u4f7f\u7528\u66f4\u4fbf\u6377\u3002\u82e5\u5bb6\u91cc\u5bf9\u7532\u919b\u3001PM2.5\u3001\u5f02\u5473\u654f\u611f\uff0c\u53ef\u5728\u9009\u914d\u65f6\u52a0PE\u6a21\u5757\u6216\u5bf9\u5e94\u6ee4\u7f51\u7ec4\u4ef6\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u98ce\u76d8\u9759\u97f3\u5230\u5e95\u80fd\u5230\u591a\u5c11\u5206\u8d1d\uff1f\u7f51\u4f20\u768419.5\u662f\u771f\u7684\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6309\u65e5\u7acb\u96f6\u8d8a\u6837\u518c\uff0c\u76f4\u6d41\u65e0\u5237\u5851\u5c01\u7535\u673a\u914d\u8f7b\u578b\u8717\u58f3\u53f6\u8f6e\uff0c\u53ef\u5b9e\u73b0\u6700\u4f4e20\u5206\u8d1d\u9759\u97f3\uff1b\u516d\u6863\u53c2\u6570\u8868\u91cc34\u578b\u5fae\u98ce\u6863\u4e3a20dB(A)\uff0c\u5bb9\u91cf\u8d8a\u5927\u566a\u97f3\u76f8\u5e94\u5347\u9ad8\u3002\u7f51\u4e0a\u6d41\u4f20\u768419.5\u8fd9\u4e2a\u6570\uff0c\u5728\u6837\u518c\u53c2\u6570\u91cc\u662f\u5236\u51b7\u8fdb\u98ce\u7684\u6e7f\u7403\u6e29\u5ea6\uff0827\/19.5\u2103\uff09\uff0c\u4e0d\u662f\u566a\u97f3\u503c\uff0c\u522b\u628a\u5de5\u51b5\u53c2\u6570\u5f53\u6210\u9759\u97f3\u6307\u6807\u3002\u770b\u9759\u97f3\u8981\u8ba4\u51c6\\\"\u5206\u8d1ddB(A)\\\"\u548c\u5bf9\u5e94\u6863\u4f4d\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u63d0\u5347\u6cf5\u626c\u7a0b1200mm\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u548c1125mm\u77db\u76fe\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e0d\u77db\u76fe\uff0c\u662f\u4e24\u6b3e\u4e0d\u540c\u4ea7\u54c1\u3002\u65e5\u7acb\u96f6\u8d8a\u8d85\u8584DC\u98ce\u76d8\u6807\u914d\u7684\u662f1200mm\u9ad8\u626c\u7a0b\u6c34\u6cf5\uff0c\u914d\u6d6e\u5b50\u5f00\u5173\u4e0e\u63a7\u5236\u8054\u52a8\u9632\u6ea2\u6c34\uff1b\u53e6\u6709\u5361\u5f0f\u98ce\u76d8\u6807\u6ce81125mm\uff0c\u5c5e\u4e8e\u4e0d\u540c\u4ea7\u54c1\u7ebf\u7684\u53c2\u6570\u3002\u8865\u4e00\u53e5\u8fb9\u754c\uff1a\u6d6e\u5b50\u5f00\u5173\u662f\u6ea2\u6c34\u4fdd\u62a4\uff0c\u4e0d\u662f\u9632\u6b62\u51b7\u51dd\u6c34\u7ba1\u5835\u585e\uff0c\u6392\u6c34\u7ba1\u4ecd\u9700\u5b9a\u671f\u6e05\u7406\u3002\u63d0\u5347\u6cf5\u7684\u4f5c\u7528\u662f\u8ba9\u51b7\u51dd\u6c34\u5728\u540a\u9876\u9ad8\u5ea6\u53d7\u9650\u3001 \u91cd\u529b\u6392\u6c34\u5761\u5ea6\u4e0d\u591f\u65f6\u4e5f\u80fd\u987a\u5229\u6392\u51fa\uff0c\u626c\u7a0b\u8d8a\u9ad8\u3001\u53ef\u514b\u670d\u7684\u6392\u6c34\u963b\u529b\u8d8a\u5927\u3002\u770b\u53c2\u6570\u8981\u8fde\u540c\u4ea7\u54c1\u578b\u53f7\u4e00\u8d77\u770b\uff0c\u522b\u628a\u4e0d\u540c\u4ea7\u54c1\u7684\u6570\u5b57\u653e\u5230\u4e00\u53f0\u673a\u5668\u4e0a\u6bd4\u8f83\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u5bb6\u91cc\u88c5\u98ce\u76d8\uff0c\u8be5\u6309\u4ec0\u4e48\u987a\u5e8f\u9009\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5148\u5b9a\u8def\u7ebf\u518d\u5b9a\u672b\u7aef\u3002\u7b2c\u4e00\u6b65\u770b\u7cfb\u7edf\uff1a\u662f\u6c1f\u7cfb\u7edf\u8d70\u98ce\u76d8\uff0c\u8fd8\u662f\u6c34\u7cfb\u7edf\uff08\u4e24\u8054\u4f9b\uff09\u8d70\u98ce\u76d8\u52a0\u5730\u6696\uff1b\u7b2c\u4e8c\u6b65\u6309\u623f\u95f4\u8d1f\u8377\u7b97\u6863\u4f4d\uff0c34\u5230119\u516d\u6863\u5bf9\u5e94\u4e0d\u540c\u9762\u79ef\u548c\u671d\u5411\uff1b\u7b2c\u4e09\u6b65\u5b9a\u5c42\u6b21\uff1a\u9884\u7b97\u7d27\u3001\u975e\u957f\u671f\u5c45\u4f4f\u53ef\u9009\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\uff0c\u5bb6\u7528\u957f\u671f\u4f4f\u4f18\u5148\u5168\u76f4\u6d41\u53d8\u9891\uff0c\u5bf9\u7532\u919b\u548cPM2.5\u654f\u611f\u518d\u52a0PE\u51c0\u5316\u6a21\u5757\uff1b\u7b2c\u56db\u6b65\u6838\u5b89\u88c5\u6761\u4ef6\u2014\u2014\u540a\u9876\u9ad8\u5ea6\u3001\u63a5\u7ba1\u65b9\u5411\u3001\u51b7\u51dd\u6c34\u600e\u4e48\u6392\u3001\u6709\u6ca1\u6709\u63d0\u5347\u6cf5\u3002\u672b\u7aef\u9009\u5bf9\u4e86\uff0c\u4e3b\u673a\u80fd\u529b\u624d\u80fd\u771f\u6b63\u843d\u5730\u3002\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\"\u540c\u6837\u662f\u98ce\u673a\u76d8\u7ba1\uff0c\u6709\u7684\u4e00\u53f0\u51e0\u767e\u5757\uff0c\u6709\u7684\u51e0 [&hellip;]<\/p>\n","protected":false},"author":20,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-20725","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4ef7\u683c\u5374\u5dee\u4e00\u5927\u622a\uff0c\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\u672c\u6587\u6309\u4e09\u4e2a\u5c42\u6b21\u8bb2\u6e05\uff1a\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u7684\u7ed3\u6784\u77ed\u677f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\uff08\u65e5\u7acb\u96f6\u8d8a\uff09\u7684\u4e03\u9879\u7279\u70b9\u4e0e\u516d\u6863\u53c2\u6570\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8\u80fd\u505a\u4ec0\u4e48\u3002\u9644\u4e09\u7c7b\u6a2a\u5411\u5bf9\u6bd4\u8868\u4e0e\u53c2\u6570\u5f15\u7528\u5fc5\u5e26\u7684\u5de5\u51b5\u8bf4\u660e\uff0c\u5e2e\u4f60\u6309\u9700\u6c42\u548c\u9884\u7b97\u9009\u5bf9\uff0c\u4e0d\u88ab&quot;\u770b\u7740\u4e00\u6837&quot;\u7ed5\u6655\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=20725\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4ef7\u683c\u5374\u5dee\u4e00\u5927\u622a\uff0c\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\u672c\u6587\u6309\u4e09\u4e2a\u5c42\u6b21\u8bb2\u6e05\uff1a\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u7684\u7ed3\u6784\u77ed\u677f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\uff08\u65e5\u7acb\u96f6\u8d8a\uff09\u7684\u4e03\u9879\u7279\u70b9\u4e0e\u516d\u6863\u53c2\u6570\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8\u80fd\u505a\u4ec0\u4e48\u3002\u9644\u4e09\u7c7b\u6a2a\u5411\u5bf9\u6bd4\u8868\u4e0e\u53c2\u6570\u5f15\u7528\u5fc5\u5e26\u7684\u5de5\u51b5\u8bf4\u660e\uff0c\u5e2e\u4f60\u6309\u9700\u6c42\u548c\u9884\u7b97\u9009\u5bf9\uff0c\u4e0d\u88ab&quot;\u770b\u7740\u4e00\u6837&quot;\u7ed5\u6655\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=20725\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-18T16:13:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725\",\"name\":\"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p11-20.jpeg\",\"datePublished\":\"2026-11-17T16:29:42+00:00\",\"dateModified\":\"2026-11-18T16:13:43+00:00\",\"description\":\"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4ef7\u683c\u5374\u5dee\u4e00\u5927\u622a\uff0c\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\u672c\u6587\u6309\u4e09\u4e2a\u5c42\u6b21\u8bb2\u6e05\uff1a\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u7684\u7ed3\u6784\u77ed\u677f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\uff08\u65e5\u7acb\u96f6\u8d8a\uff09\u7684\u4e03\u9879\u7279\u70b9\u4e0e\u516d\u6863\u53c2\u6570\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8\u80fd\u505a\u4ec0\u4e48\u3002\u9644\u4e09\u7c7b\u6a2a\u5411\u5bf9\u6bd4\u8868\u4e0e\u53c2\u6570\u5f15\u7528\u5fc5\u5e26\u7684\u5de5\u51b5\u8bf4\u660e\uff0c\u5e2e\u4f60\u6309\u9700\u6c42\u548c\u9884\u7b97\u9009\u5bf9\uff0c\u4e0d\u88ab\\\"\u770b\u7740\u4e00\u6837\\\"\u7ed5\u6655\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p11-20.jpeg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-lmnt-shxdrl-p11-20.jpeg\",\"width\":440,\"height\":275},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20725#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05 - \u9f99\u8109\u6696\u901a","description":"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4ef7\u683c\u5374\u5dee\u4e00\u5927\u622a\uff0c\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\u672c\u6587\u6309\u4e09\u4e2a\u5c42\u6b21\u8bb2\u6e05\uff1a\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u7684\u7ed3\u6784\u77ed\u677f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\uff08\u65e5\u7acb\u96f6\u8d8a\uff09\u7684\u4e03\u9879\u7279\u70b9\u4e0e\u516d\u6863\u53c2\u6570\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8\u80fd\u505a\u4ec0\u4e48\u3002\u9644\u4e09\u7c7b\u6a2a\u5411\u5bf9\u6bd4\u8868\u4e0e\u53c2\u6570\u5f15\u7528\u5fc5\u5e26\u7684\u5de5\u51b5\u8bf4\u660e\uff0c\u5e2e\u4f60\u6309\u9700\u6c42\u548c\u9884\u7b97\u9009\u5bf9\uff0c\u4e0d\u88ab\"\u770b\u7740\u4e00\u6837\"\u7ed5\u6655\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=20725","og_locale":"zh_CN","og_type":"article","og_title":"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05 - \u9f99\u8109\u6696\u901a","og_description":"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4ef7\u683c\u5374\u5dee\u4e00\u5927\u622a\uff0c\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\u672c\u6587\u6309\u4e09\u4e2a\u5c42\u6b21\u8bb2\u6e05\uff1a\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u7684\u7ed3\u6784\u77ed\u677f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\uff08\u65e5\u7acb\u96f6\u8d8a\uff09\u7684\u4e03\u9879\u7279\u70b9\u4e0e\u516d\u6863\u53c2\u6570\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8\u80fd\u505a\u4ec0\u4e48\u3002\u9644\u4e09\u7c7b\u6a2a\u5411\u5bf9\u6bd4\u8868\u4e0e\u53c2\u6570\u5f15\u7528\u5fc5\u5e26\u7684\u5de5\u51b5\u8bf4\u660e\uff0c\u5e2e\u4f60\u6309\u9700\u6c42\u548c\u9884\u7b97\u9009\u5bf9\uff0c\u4e0d\u88ab\"\u770b\u7740\u4e00\u6837\"\u7ed5\u6655\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=20725","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-18T16:13:43+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=20725","url":"https:\/\/longmai-nt.com\/?page_id=20725","name":"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=20725#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=20725#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg","datePublished":"2026-11-17T16:29:42+00:00","dateModified":"2026-11-18T16:13:43+00:00","description":"\u98ce\u673a\u76d8\u7ba1\u770b\u7740\u90fd\u5dee\u4e0d\u591a\uff0c\u4ef7\u683c\u5374\u5dee\u4e00\u5927\u622a\uff0c\u5dee\u522b\u5230\u5e95\u5728\u54ea\uff1f\u672c\u6587\u6309\u4e09\u4e2a\u5c42\u6b21\u8bb2\u6e05\uff1a\u534a\u5305\u5f0f\u5de5\u7a0b\u673a\u7684\u7ed3\u6784\u77ed\u677f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u5bb6\u7528\u673a\uff08\u65e5\u7acb\u96f6\u8d8a\uff09\u7684\u4e03\u9879\u7279\u70b9\u4e0e\u516d\u6863\u53c2\u6570\u3001\u5e26PE\u51c0\u5316\u6a21\u5757\u7684\u51c0\u5316\u98ce\u76d8\u80fd\u505a\u4ec0\u4e48\u3002\u9644\u4e09\u7c7b\u6a2a\u5411\u5bf9\u6bd4\u8868\u4e0e\u53c2\u6570\u5f15\u7528\u5fc5\u5e26\u7684\u5de5\u51b5\u8bf4\u660e\uff0c\u5e2e\u4f60\u6309\u9700\u6c42\u548c\u9884\u7b97\u9009\u5bf9\uff0c\u4e0d\u88ab\"\u770b\u7740\u4e00\u6837\"\u7ed5\u6655\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=20725#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=20725"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=20725#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-lmnt-shxdrl-p11-20.jpeg","width":440,"height":275},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=20725#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u98ce\u673a\u76d8\u7ba1\u600e\u4e48\u9009\uff1f\u534a\u5305\u5f0f\u3001\u5168\u76f4\u6d41\u53d8\u9891\u3001\u5e26\u51c0\u5316\u4e09\u4e2a\u5c42\u6b21\u4e00\u6b21\u8bb2\u6e05"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20725"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20725\/revisions"}],"predecessor-version":[{"id":20794,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20725\/revisions\/20794"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}