{"id":20906,"date":"2026-11-20T15:12:44","date_gmt":"2026-11-20T07:12:44","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=20906"},"modified":"2026-11-21T11:18:25","modified_gmt":"2026-11-21T03:18:25","slug":"%e7%94%b5%e5%ad%90%e7%a7%91%e5%a4%a7%e4%b8%9c%e4%ba%8c%e9%99%a2-%c2%b7-%e7%8e%8b%e5%a5%b3%e5%a3%ab%e5%ae%b6%ef%bd%9c%e6%9b%bc%e7%91%9e%e5%be%b7%e5%8d%95%e9%87%87%e6%9a%96%e7%82%89-%e8%87%aa%e7%84%b6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=20906","title":{"rendered":"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b"},"content":{"rendered":"\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"@id\": \"https:\/\/longmai-nt.com\/#article-dzxx-wang-case-20261119\",\n      \"headline\": \"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b\",\n      \"description\": \"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u8d70\u5f27\u5f62\u6263\u69fd\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf5525W\uff0c2026-11\u7ae3\u5de5\u9a8c\u6536\u3002\",\n      \"author\": {\n        \"@type\": \"Person\",\n        \"@id\": \"https:\/\/longmai-nt.com\/#person-hy\",\n        \"name\": \"\u9ec4\u52c7\",\n        \"description\": \"2004\u5e74\u8d77\u6df1\u8015\u6696\u901a\"\n      },\n      \"publisher\": {\n        \"@id\": \"https:\/\/longmai-nt.com\/#org\"\n      },\n      \"datePublished\": \"2026-11-19\",\n      \"dateModified\": \"2026-11-19\",\n      \"mainEntityOfPage\": {\n        \"@type\": \"WebPage\",\n        \"@id\": \"https:\/\/longmai-nt.com\/?page_id=20906\"\n      },\n      \"about\": [\n        \"\u660e\u88c5\u6696\u6c14\u7247\",\n        \"\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089\",\n        \"\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247\",\n        \"\u5df2\u88c5\u4fee\u623f\u91c7\u6696\",\n        \"\u6210\u90fd\u6696\u6c14\u7247\u6848\u4f8b\"\n      ],\n      \"image\": [\n        \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang01.jpg\",\n        \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guanluanzhuang01.jpg\",\n        \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou02.jpg\"\n      ],\n      \"inLanguage\": \"zh-CN\",\n      \"articleSection\": \"\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b\",\n      \"keywords\": \"\u660e\u88c5\u6696\u6c14\u7247,\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089,\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247,\u5df2\u88c5\u4fee\u623f\u91c7\u6696,\u6210\u90fd\u6696\u6c14\u7247\u6848\u4f8b,\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\",\n      \"wordCount\": 4027\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"@id\": \"https:\/\/longmai-nt.com\/#faq-dzkd-wang-20261119\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u660e\u88c5\u6696\u6c14\u7247\u4f1a\u7834\u574f\u5df2\u88c5\u4fee\u7684\u623f\u5b50\u5417\uff1f\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"\u660e\u88c5\u91c7\u7528\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247\uff0c\u7ba1\u8def\u8d70\u660e\u7ba1\u5e76\u7528\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u4e0d\u6253\u6d1e\u3001\u4e0d\u52a8\u5730\u9762\uff0c\u5bf9\u73b0\u6709\u88c5\u4fee\u7834\u574f\u8f83\u5c0f\uff0c\u9002\u5408\u5df2\u88c5\u4fee\u623f\u5feb\u901f\u91c7\u6696\u3002\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089\u540c\u65f6\u89e3\u51b3\u751f\u6d3b\u70ed\u6c34\u5417\uff1f\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"\u672c\u6848\u4e3a\u5355\u91c7\u6696\u7089\uff08N1PB18-HI.Pro\uff09\uff0c\u4ec5\u8d1f\u8d23\u91c7\u6696\uff1b\u751f\u6d3b\u70ed\u6c34\u7531\u539f\u6709\u70ed\u6c34\u5668\u63d0\u4f9b\u3002\u82e5\u9700\u91c7\u6696\u4e0e\u70ed\u6c34\u4e00\u4f53\uff0c\u5e94\u9009\u4e24\u7528\u7089\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u65b9\u6848\u4e3a\u51c6\u3002\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u5df2\u88c5\u4fee\u623f\u505a\u660e\u88c5\u6696\u6c14\uff0c\u54ea\u4e9b\u4e8b\u8981\u63d0\u524d\u5b9a\uff1f\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"\u660e\u88c5\u8d70\u660e\u7ba1\u9700\u8981\u6263\u69fd\u906e\u853d\uff0c\u9505\u7089\u6c34\u7535\u6c14\u63a5\u53e3\u8981\u7531\u4e1a\u4e3b\u534f\u8c03\u9884\u7559\u5230\u4ea4\u5e95\u6307\u5b9a\u4f4d\u7f6e\uff1b\u6807\u914d\u70df\u7ba1\u957f\u5ea6\u6709\u9650\uff0c\u52a0\u957f\u70df\u7ba1\u3001\u5730\u652f\u67b6\u3001\u536b\u751f\u95f4\u4e0e\u53a8\u623f\u9632\u6c34\u7b49\u9700\u53e6\u884c\u786e\u8ba4\u3002\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"\u600e\u4e48\u9884\u7ea6\u540c\u6237\u578b\u52d8\u6d4b\u4e0e\u914d\u7f6e\u53c2\u8003\uff1f\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u81f4\u753515828489188\uff08\u9ec4\u52c7\uff09\u5373\u53ef\u9884\u7ea6\uff0c\u83b7\u53d6\u540c\u6237\u578b\u7684\u914d\u7f6e\u53c2\u8003\u4e0e\u5206\u9879\u8bf4\u660e\u3002\"\n          }\n        }\n      ]\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"itemListElement\": [\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 1,\n          \"name\": \"\u9996\u9875\",\n          \"item\": \"https:\/\/longmai-nt.com\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 2,\n          \"name\": \"\u6696\u6c14\u7247\u6848\u4f8b\",\n          \"item\": \"https:\/\/longmai-nt.com\/?page_id=5556\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 3,\n          \"name\": \"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662 \u00b7 \u738b\u5973\u58eb\u660e\u88c5\u6696\u6c14\u7247\u6848\u4f8b\"\n        }\n      ]\n    },\n    {\n      \"@type\": \"LocalBusiness\",\n      \"@id\": \"https:\/\/longmai-nt.com\/#org\",\n      \"name\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\n      \"url\": \"https:\/\/longmai-nt.com\",\n      \"telephone\": [\n        \"028-86131795\",\n        \"028-65272586\"\n      ],\n      \"image\": [\n        \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\",\n        \"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\"\n      ],\n      \"address\": {\n        \"@type\": \"PostalAddress\",\n        \"streetAddress\": \"\u5bcc\u68ee\u7f8e\u5bb6\u5c453\u697cA348\",\n        \"addressLocality\": \"\u9ad8\u65b0\u533a\",\n        \"addressRegion\": \"\u6210\u90fd\u5e02\",\n        \"addressCountry\": \"CN\"\n      },\n      \"openingHours\": \"Mo-Su 09:00-18:00\"\n    }\n  ]\n}\n<\/script>\n<style>\n.lm-wrapper{--main:#9a7b3f;--deep:#5a4520;--gold:#c9a227;--bg:#fbf7ef;--ink:#3a2f23;--line:#e3d6bd;--soft:#fbf6ea;max-width:1080px;margin:0 auto;padding:0 18px 40px;background:var(--bg);color:var(--ink);font-size:14px;line-height:1.75;font-family:\"Noto Serif SC\",\"Microsoft YaHei\",Georgia,serif;-webkit-font-smoothing:antialiased}\n.lm-wrapper *{box-sizing:border-box}\n.lm-wrapper a{color:#1a5cb0;text-decoration:none}\n.lm-hero{position:relative;background:linear-gradient(180deg,rgba(40,28,10,.66),rgba(40,28,10,.82)),url('https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang01.jpg') center\/cover no-repeat;border-radius:0 0 16px 16px;padding:48px 30px 34px;margin:0 -18px 18px;color:#fff;text-align:center}\n.lm-hero .ey{font-size:13px;color:#f0d9a0;letter-spacing:3px;font-weight:700}\n.lm-hero h1{font-size:1.9rem;line-height:1.4;margin:12px auto;color:#fff;font-weight:800;text-shadow:0 2px 10px rgba(0,0,0,.45)}\n.lm-hero .sub{font-size:1rem;color:#f5e7c8;margin:8px auto 16px}\n.lm-hero .chips{display:flex;flex-wrap:wrap;gap:9px;justify-content:center}\n.lm-hero .chip{background:rgba(255,255,255,.14);border:1px solid rgba(255,255,255,.35);border-radius:20px;padding:5px 15px;font-size:.85rem;backdrop-filter:blur(2px)}\n.lm-toc{position:sticky;top:0;z-index:20;background:#fffdf8;border:1px solid var(--line);border-bottom:2px solid var(--gold);border-radius:10px;margin:0 0 18px;padding:0}\n.lm-toc-in{display:flex;gap:2px;overflow-x:auto;padding:6px 8px}\n.lm-toc a{white-space:nowrap;padding:8px 13px;font-size:.88rem;color:var(--deep);font-weight:600;border-bottom:3px solid transparent}\n.lm-toc a:hover{border-color:var(--main);color:var(--main)}\n.lm-flips{display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:0 0 20px}\n.lm-flip{perspective:1200px;min-height:250px;cursor:pointer}\n.lm-flip-in{position:relative;width:100%;height:100%;min-height:250px;transition:transform .7s;transform-style:preserve-3d}\n.lm-flip.on .lm-flip-in{transform:rotateY(180deg)}\n.lm-face{position:absolute;inset:0;backface-visibility:hidden;border-radius:12px;padding:18px 20px;overflow:auto;border:1px solid var(--line)}\n.lm-face-f{background:linear-gradient(145deg,#fffdf8,#fbf3e3)}\n.lm-face-b{background:linear-gradient(145deg,#5a4520,#7a5a28);color:#fff;transform:rotateY(180deg)}\n.lm-face h3{font-size:1rem;margin:0 0 12px;color:var(--main);border-left:4px solid var(--gold);padding-left:9px}\n.lm-face-b h3{color:#ffe2b0;border-color:#ffe2b0}\n.lm-arc{display:flex;justify-content:space-between;gap:10px;border-bottom:1px dashed var(--line);padding:5px 2px;font-size:.88rem}\n.lm-arc b{color:var(--deep)}\n.lm-face-b .lm-arc{border-color:rgba(255,255,255,.25)}\n.lm-kw{display:inline-block;background:rgba(154,123,63,.1);border:1px solid var(--line);border-radius:16px;padding:3px 11px;margin:4px 3px;font-size:.82rem;color:var(--deep)}\n.lm-face-b .lm-kw{background:rgba(255,255,255,.12);border-color:rgba(255,255,255,.4);color:#fff}\n.lm-tip{font-size:.76rem;color:#a88a58;text-align:right;margin-top:8px}\n.lm-face-b .lm-tip{color:#ffe2b0}\n.lm-voice{background:#fdf3e3;border-left:4px solid var(--gold);border-radius:0 8px 8px 0;padding:10px 13px;margin:8px 0;font-size:.9rem}\n.lm-voice b{color:var(--deep)}\n.lm-sec{margin:30px 0}\n.lm-sec-h{display:flex;align-items:center;gap:10px;margin:0 0 14px}\n.lm-sec-h .no{background:var(--main);color:#fff;border-radius:8px;padding:4px 12px;font-weight:700;font-size:.92rem}\n.lm-sec-h h2{font-size:1.3rem;color:var(--deep)}\n.lm-card{background:#fffdf8;border:1px solid var(--line);border-radius:12px;padding:20px 22px;margin-bottom:14px}\n.lm-card h3{color:var(--main);font-size:1.02rem;margin:0 0 10px}\n.lm-grid2{display:grid;grid-template-columns:1fr 1fr;gap:12px}\n.lm-table{width:100%;border-collapse:collapse;margin:10px 0;font-size:.9rem}\n.lm-table th{background:var(--deep);color:#fff;padding:9px 10px;text-align:left}\n.lm-table td{border:1px solid var(--line);padding:8px 10px;background:#fff}\n.lm-table tr:nth-child(even) td{background:var(--soft)}\n.lm-table .hl td{background:#fdf0da!important;font-weight:700}\n.lm-concl{background:linear-gradient(90deg,var(--deep),var(--main));color:#fff;border-radius:10px;padding:13px 17px;margin:12px 0;font-size:.95rem}\n.lm-note{font-size:.85rem;color:#6b5b3e;background:var(--soft);border:1px dashed var(--gold);border-radius:8px;padding:10px 13px;margin:10px 0}\n.lm-ul{margin:4px 0 0;padding-left:20px}\n.lm-ul li{margin:6px 0}\n.lm-ul li::marker{color:var(--main)}\n.lm-g-title{font-weight:700;color:var(--main);font-size:1rem;margin:18px 0 8px;padding-left:10px;border-left:4px solid var(--gold)}\n.lm-phgrid{display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin:10px 0}\n.lm-phgrid figure{margin:0;background:#fff;border:1px solid var(--line);border-radius:10px;overflow:hidden}\n.lm-phgrid img{width:100%;aspect-ratio:4\/3;object-fit:cover;display:block}\n.lm-phgrid figcaption{padding:7px 9px;font-size:.8rem;color:#7a5a38;text-align:center;background:#fdf8f0}\n.lm-steps{display:grid;grid-template-columns:1fr 1fr;gap:6px 18px;margin:6px 0}\n.lm-step{display:flex;gap:8px;border-bottom:1px dashed var(--line);padding:6px 2px;font-size:.88rem}\n.lm-step .n{color:var(--main);font-weight:800;flex:0 0 auto}\n.lm-faq{background:#fffdf8;border:1px solid var(--line);border-radius:10px;padding:12px 18px;margin-bottom:9px}\n.lm-faq dt{font-weight:700;color:var(--deep);margin-bottom:5px}\n.lm-faq dd{margin:0;color:var(--ink);font-size:.92rem}\n.lm-stores{display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:10px 0}\n.lm-store{background:#fffdf8;border:1px solid var(--line);border-radius:12px;padding:14px}\n.lm-store .nm{font-weight:800;color:var(--deep);font-size:1rem;margin-bottom:7px}\n.lm-store img{width:100%;height:120px;object-fit:cover;border-radius:8px;margin-bottom:8px;display:block}\n.lm-store .ln{font-size:.88rem;margin:3px 0}\n.lm-store .amap{display:inline-block;margin-top:8px;background:var(--main);color:#fff;font-size:.82rem;padding:6px 12px;border-radius:8px;font-weight:600}\n.lm-cta{background:linear-gradient(135deg,#f0e6d2,#e3d0a4);border:1px solid var(--gold);color:var(--deep);border-radius:14px;padding:24px;text-align:center;margin:22px 0}\n.lm-cta h2{margin:0 0 8px;font-size:1.3rem}\n.lm-cta p{color:#6b5b3e;margin-bottom:14px}\n.lm-btn{display:inline-block;margin:5px;background:var(--main);color:#fff;font-weight:700;padding:10px 22px;border-radius:26px}\n.lm-btn.o{background:transparent;color:var(--deep);border:2px solid var(--main)}\n.lm-rel{background:#fffdf8;border:1px solid var(--line);border-left:4px solid var(--gold);border-radius:10px;padding:16px 20px}\n.lm-rel h3{font-size:1rem;margin:0 0 8px;color:var(--deep)}\n.lm-rel a{color:#1a5cb0;margin-right:14px;line-height:2;font-size:.9rem}\n.lm-links{display:grid;grid-template-columns:repeat(2,1fr);gap:10px;margin-top:12px}\n.lm-link-card{display:block;background:#fffdf8;border:1px solid var(--line);border-left:4px solid var(--gold);border-radius:10px;padding:12px 14px;transition:transform .2s,box-shadow .2s}\n.lm-link-card:hover{transform:translateY(-2px);box-shadow:0 6px 16px rgba(90,69,32,.15)}\n.lm-link-card .t{font-weight:700;color:var(--deep);font-size:.95rem;display:block;margin-bottom:3px}\n.lm-link-card .d{color:#7a6a4e;font-size:.82rem;line-height:1.5;display:block}\n.lm-foot{font-size:.8rem;color:#8a7a5e;text-align:center;margin-top:20px}\n@media(max-width:700px){.lm-flips,.lm-grid2,.lm-stores,.lm-steps,.lm-links{grid-template-columns:1fr}.lm-phgrid{grid-template-columns:repeat(2,1fr)}.lm-hero h1{font-size:1.4rem}}\n<\/style>\n<div class=\"lm-wrapper\">\n\n<div class=\"lm-hero\">\n  <div class=\"ey\">\u9f99\u8109\u6696\u901a \u00b7 \u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b<\/div>\n  <h2>\u5df2\u88c5\u4fee\u623f\u4e0d\u52a8\u5730\u9762<br>42.5\u33a1 \u660e\u88c5\u6696\u6c14\uff0c\u4e00\u4e2a\u51ac\u5929\u5c31\u80fd\u7528<\/h2>\n  <div class=\"sub\">\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662 \u00b7 \u738b\u5973\u58eb\u5bb6\uff5c\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089 + \u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 4 \u7ec4\uff0c2026 \u5e74 11 \u6708\u7ae3\u5de5\u9a8c\u6536<\/div>\n  <div class=\"chips\">\n    <span class=\"chip\">\ud83d\udccd \u6210\u90fd \u00b7 \u7535\u5b50\u79d1\u5927\u7247\u533a<\/span>\n    <span class=\"chip\">\ud83c\udfe0 \u5df2\u88c5\u4fee\u623f \u00b7 \u91c7\u6696 42.5\u33a1<\/span>\n    <span class=\"chip\">\ud83d\udd25 \u66fc\u745e\u5fb7 18kW \u5355\u91c7\u6696\u7089<\/span>\n    <span class=\"chip\">\u2668\ufe0f \u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 \u00d74<\/span>\n    <span class=\"chip\">\ud83d\udee1\ufe0f \u9f99\u8109\u6696\u901a 20 \u4f59\u5e74\u7cbe\u5de5<\/span>\n  <\/div>\n<\/div>\n\n<div class=\"lm-toc\"><div class=\"lm-toc-in\">\n  <a href=\"#s1\">\u2460 \u5ba2\u6237\u76ee\u6807<\/a>\n  <a href=\"#s2\">\u2461 \u9700\u6c42\u8bca\u65ad<\/a>\n  <a href=\"#s3\">\u2462 \u65b9\u6848\u914d\u7f6e<\/a>\n  <a href=\"#s4\">\u2463 \u65bd\u5de5\u4ea4\u4ed8<\/a>\n  <a href=\"#s5\">\u2464 \u6548\u679c\u4e0e\u95ee\u7b54<\/a>\n  <a href=\"#stores\">\ud83d\udccd \u95e8\u5e97<\/a>\n  <a href=\"#links\">\ud83d\udd17 \u5173\u8054\u9605\u8bfb<\/a>\n<\/div><\/div>\n\n<div class=\"lm-flips\">\n  <div class=\"lm-flip\" onclick=\"this.classList.toggle('on')\">\n    <div class=\"lm-flip-in\">\n      <div class=\"lm-face lm-face-f\">\n        <h3>\ud83d\udccb \u6848\u4f8b\u6863\u6848\uff08\u70b9\u51fb\u7ffb\u9762\u770b\u7126\u70b9\uff09<\/h3>\n        <div class=\"lm-arc\"><span>\u9879\u76ee<\/span><b>\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\uff08\u5df2\u88c5\u4fee\u623f\uff09<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u533a\u57df<\/span><b>\u6210\u90fd \u00b7 \u7535\u5b50\u79d1\u5927\u7247\u533a<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u5ba2\u6237<\/span><b>\u738b\u5973\u58eb\uff08\u719f\u4eba\u5f15\u8350\uff09<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u91c7\u6696\u9762\u79ef<\/span><b>42.5\u33a1\uff08\u5ba2\u9910\u4e3b\u6b21\u56db\u533a\uff09<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u7cfb\u7edf<\/span><b>\u660e\u88c5\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u70ed\u6e90<\/span><b>\u66fc\u745e\u5fb7 N1PB18-HI.Pro \u00b7 18kW<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u672b\u7aef<\/span><b>\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 \u00d74 \u7ec4<\/b><\/div>\n        <div class=\"lm-arc\"><span>\u4ea4\u4ed8<\/span><b>2026-11 \u7ae3\u5de5\u9a8c\u6536\u5408\u683c<\/b><\/div>\n        <div class=\"lm-tip\">\ud83d\udc46 \u70b9\u51fb\u5361\u7247\u7ffb\u9762<\/div>\n      <\/div>\n      <div class=\"lm-face lm-face-b\">\n        <h3>\ud83d\udd0d \u672c\u6848\u7126\u70b9\u5173\u952e\u8bcd<\/h3>\n        <span class=\"lm-kw\">\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14<\/span>\n        <span class=\"lm-kw\">\u4e0d\u52a8\u5730\u9762\u4e0d\u7834\u88c5\u4fee<\/span>\n        <span class=\"lm-kw\">\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089<\/span>\n        <span class=\"lm-kw\">\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247<\/span>\n        <span class=\"lm-kw\">\u4f1f\u661f\u94dd\u5851\u7ba1 + \u5f27\u5f62\u6263\u69fd<\/span>\n        <span class=\"lm-kw\">42.5\u33a1 \/ 5,525W<\/span>\n        <span class=\"lm-kw\">\u719f\u4eba\u5f15\u8350<\/span>\n        <span class=\"lm-kw\">18 \u5929\u4ea4\u4ed8<\/span>\n        <span class=\"lm-kw\">\u6210\u90fd\u5168\u57df\u514d\u8d39\u52d8\u6d4b<\/span>\n        <div class=\"lm-tip\">\ud83d\udc46 \u70b9\u51fb\u5361\u7247\u7ffb\u56de\u6863\u6848<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n  <div class=\"lm-flip\" onclick=\"this.classList.toggle('on')\">\n    <div class=\"lm-flip-in\">\n      <div class=\"lm-face lm-face-f\">\n        <h3>\ud83d\udcac \u5ba2\u6237\u4e3a\u4ec0\u4e48\u9009\u9f99\u8109\uff08\u70b9\u51fb\u7ffb\u9762\uff09<\/h3>\n        <div class=\"lm-voice\">\u300c\u5bb6\u91cc\u5df2\u7ecf\u88c5\u4fee\u597d\u4e86\uff0c\u5c31\u6015\u88c5\u6696\u6c14\u8981\u628a\u5730\u9762\u64ac\u4e86\u3002\u300d<br>\u2014\u2014 \u719f\u4eba\u5f15\u8350\u800c\u6765\uff0c\u6700\u5728\u610f\u7684\u662f\u5c11\u52a8\u88c5\u4fee\u3002<\/div>\n        <div class=\"lm-voice\">\u300c\u56db\u4e2a\u623f\u95f4\u51ac\u5929\u8981\u80fd\u6696\u8d77\u6765\uff0c\u65b9\u6848\u5b9e\u5728\u3001\u5de5\u671f\u77ed\u5c31\u884c\u3002\u300d<br>\u2014\u2014 \u4e0d\u8ffd\u6c42\u5806\u914d\u7f6e\uff0c\u6309\u771f\u5b9e\u9700\u6c42\u914d\u591f\u7528\u7684\u65b9\u6848\u3002<\/div>\n        <div class=\"lm-tip\">\ud83d\udc46 \u70b9\u51fb\u5361\u7247\u7ffb\u9762\u770b\u9009\u578b\u903b\u8f91<\/div>\n      <\/div>\n      <div class=\"lm-face lm-face-b\">\n        <h3>\ud83d\udca1 \u4e3a\u4ec0\u4e48\u8fd9\u6837\u914d<\/h3>\n        <p style=\"font-size:.9rem;\">\u8fd9\u662f\u4e00\u5957\u4e3a\u201c\u5df2\u88c5\u4fee\u623f\u3001\u53ea\u89e3\u51b3\u51ac\u5b63\u91c7\u6696\u3001\u5c11\u52a8\u88c5\u4fee\u201d\u91cf\u8eab\u5339\u914d\u7684\u660e\u88c5\u65b9\u6848\uff1a\u66fc\u745e\u5fb7 18kW \u5355\u91c7\u6696\u7089\u4e13\u6ce8\u91c7\u6696\uff0c\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 4 \u7ec4\uff0c\u8986\u76d6\u5ba2\u5385\u3001\u9910\u5385\u3001\u4e3b\u5367\u3001\u6b21\u5367\u56db\u4e2a\u623f\u95f4\uff1b\u7ba1\u8def\u8d70\u660e\u7ba1\u5e76\u7528\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u4e0d\u52a8\u5730\u9762\u3001\u5de5\u671f\u77ed\uff0c\u628a\u5bf9\u73b0\u6709\u88c5\u4fee\u7684\u5f71\u54cd\u964d\u5230\u8f83\u4f4e\u3002\u914d\u7f6e\u6309\u5b9e\u9645\u91c7\u6696\u9700\u6c42\u9009\u591f\u7528\uff0c\u4e0d\u505a\u8d85\u51fa\u4f7f\u7528\u9700\u8981\u7684\u529f\u80fd\u5806\u52a0\u3002<\/p>\n        <div class=\"lm-tip\">\ud83d\udc46 \u70b9\u51fb\u7ffb\u56de<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<section class=\"lm-sec\" id=\"s1\">\n  <div class=\"lm-sec-h\"><span class=\"no\">1<\/span><h2>\ud83d\udd25 \u5ba2\u6237\u6210\u529f\u76ee\u6807<\/h2><\/div>\n  <div class=\"lm-card\">\n    <h3>\u4e1a\u4e3b\u60c5\u51b5<\/h3>\n    <p>\u738b\u5973\u58eb\u5bb6\u4f4d\u4e8e<b>\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a<\/b>\u7684\u4e00\u5957<strong>\u5df2\u7ecf\u88c5\u4fee\u597d\u7684\u623f\u5b50<\/strong>\uff0c\u5ba2\u5385\u3001\u9910\u5385\u3001\u4e3b\u5367\u3001\u6b21\u5367\u5171 <strong>42.5\u33a1<\/strong> \u9700\u8981\u91c7\u6696\uff08\u5ba2\u5385\u7ea614\u33a1\uff0f\u9910\u5385\u7ea66.5\u33a1\uff0f\u4e3b\u5367\u7ea612\u33a1\uff0f\u6b21\u5367\u7ea610\u33a1\uff09\u3002\u8fd9\u4e00\u6237\u7531<strong>\u719f\u4eba\u5f15\u8350<\/strong>\u627e\u5230\u9f99\u8109\u6696\u901a\uff0c\u6838\u5fc3\u8bc9\u6c42\u5f88\u660e\u786e\uff1a\u51ac\u5b63\u56db\u4e2a\u623f\u95f4\u90fd\u8981\u6696\uff0c\u4f46\u4e0d\u613f\u62c6\u5730\u9762\u3001\u4e0d\u613f\u5927\u8303\u56f4\u6539\u52a8\u5df2\u5b8c\u6210\u7684\u88c5\u4fee\uff0c\u5e0c\u671b\u65b9\u6848\u5b9e\u5728\u3001\u5de5\u671f\u77ed\u3002<\/p>\n  <\/div>\n  <div class=\"lm-grid2\">\n    <div class=\"lm-card\"><h3>\u2744\ufe0f \u51ac\u5929\u8981\u6696\u5f97\u8d77\u6765<\/h3><p>\u6309 <b>130W\/\u33a1<\/b> \u8bbe\u8ba1\u53e3\u5f84\uff0c\u603b\u5236\u70ed\u91cf\u7ea6 <b>5,525W<\/b>\uff0c\u56db\u4e2a\u623f\u95f4\u51ac\u5b63\u76ee\u6807\u5ba4\u6e29 18~22\u2103\uff0c\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247\u5feb\u901f\u5347\u6e29\u3002<\/p><\/div>\n    <div class=\"lm-card\"><h3>\ud83c\udfe0 \u4e0d\u7834\u574f\u5df2\u88c5\u4fee<\/h3><p>\u660e\u7ba1\u8d70\u7ebf + 40\u00d780 \u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u4e0d\u6253\u6d1e\u3001\u4e0d\u52a8\u5730\u9762\uff0c\u5c3d\u91cf\u8d34\u5408\u539f\u6709\u88c5\u4fee\uff0c\u5de5\u671f\u77ed\u3001\u5bf9\u5c45\u4f4f\u5f71\u54cd\u5c0f\u3002<\/p><\/div>\n    <div class=\"lm-card\"><h3>\ud83d\udcb0 \u914d\u7f6e\u914d\u51c6\u4e0d\u5806\u6599<\/h3><p>\u6309\u771f\u5b9e\u9700\u6c42\u9009\u5355\u91c7\u6696\u7089 + 4 \u7ec4\u6696\u6c14\u7247\uff0c\u914d\u7f6e\u4e0e\u672c\u6848\u51ac\u5b63\u91c7\u6696\u9700\u6c42\u5bf9\u5e94\uff0c\u4e0d\u505a\u8d85\u51fa\u4f7f\u7528\u9700\u8981\u7684\u529f\u80fd\u5806\u52a0\u3002<\/p><\/div>\n    <div class=\"lm-card\"><h3>\ud83d\udd27 \u9759\u97f3\u65e0\u98ce\u611f\u3001\u53ef\u8ffd\u6eaf<\/h3><p>\u81ea\u7136\u5bf9\u6d41\u6563\u70ed\uff0c\u65e0\u98ce\u611f\u3001\u8fd0\u884c\u5b89\u9759\uff1b\u9690\u853d\u8282\u70b9\u62cd\u7167\u5efa\u6863\uff0c\u6253\u538b\u8bd5\u9a8c\u7559\u6863\uff0c\u53ef\u8ffd\u6eaf\u53ef\u6838\u9a8c\u3002<\/p><\/div>\n  <\/div>\n  <div class=\"lm-concl\">\ud83c\udfaf \u6838\u5fc3\u76ee\u6807\uff1a\u7528\u4e00\u5957<b>\"\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089 + \u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247\"\u7684\u660e\u88c5\u7cfb\u7edf<\/b>\uff0c\u89e3\u51b3\u5df2\u88c5\u4fee\u623f 42.5\u33a1 \u7684\u51ac\u5b63\u91c7\u6696\uff0c\u4e0d\u52a8\u5730\u9762\u3001\u5de5\u671f\u77ed\u3001\u5c11\u7834\u88c5\u4fee\uff0c\u628a\u914d\u7f6e\u914d\u51c6\u800c\u4e0d\u662f\u5806\u9ad8\u3002<\/div>\n<\/section>\n\n<section class=\"lm-sec\" id=\"s2\">\n  <div class=\"lm-sec-h\"><span class=\"no\">2<\/span><h2>\ud83c\udfaf \u9700\u6c42\u75db\u70b9\u8bca\u65ad<\/h2><\/div>\n  <div class=\"lm-card\">\n    <h3>\ud83d\udce2 \u663e\u6027\u9700\u6c42<\/h3>\n    <p>\u2460 \u5ba2\u5385\u3001\u9910\u5385\u3001\u4e3b\u5367\u3001\u6b21\u5367\u56db\u4e2a\u533a\u57df\u51ac\u5b63\u90fd\u8981\u8fbe\u5230\u8212\u9002\u5ba4\u6e29\uff1b\u2461 \u5df2\u88c5\u4fee\u623f\u4e0d\u80fd\u62c6\u5730\u9762\u3001\u4e0d\u80fd\u5927\u6539\u5899\u9762\uff1b\u2462 \u5347\u6e29\u8981\u5feb\u3001\u8fd0\u884c\u8981\u5b89\u9759\u65e0\u98ce\u611f\uff1b\u2463 \u65b9\u6848\u4e0e\u5de5\u671f\u5b9e\u5728\uff0c\u5c3d\u5feb\u7528\u4e0a\uff1b\u2464 \u7531\u719f\u4eba\u5f15\u8350\uff0c\u4fe1\u4efb\u5ea6\u9ad8\u3001\u51b3\u7b56\u5feb\u3002<\/p>\n  <\/div>\n  <div class=\"lm-card\">\n    <h3>\ud83d\udd0d \u9690\u6027\u75db\u70b9\uff08\u5ba2\u6237\u6ca1\u660e\u8bf4\uff0c\u4f46\u5fc5\u987b\u66ff\u4ed6\u60f3\u5230\uff09<\/h3>\n    <ul class=\"lm-ul\">\n      <li><b>\u6015\u64ac\u5730\u9762\u6bc1\u88c5\u4fee<\/b>\u2014\u2014\u660e\u88c5\u8d70\u660e\u7ba1 + \u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u4e0d\u6253\u6d1e\u3001\u4e0d\u52a8\u5730\u9762\u3002<\/li>\n      <li><b>\u6015\u660e\u7ba1\u7a81\u5140\u96be\u770b<\/b>\u2014\u2014\u7ba1\u8def\u8d34\u5899\u89d2\u3001\u8d70\u8e22\u811a\u7ebf\uff0c\u6263\u69fd\u906e\u853d\u6a2a\u5e73\u7ad6\u76f4\u3002<\/li>\n      <li><b>\u6015\u5206\u644a\u6570\u636e\u4e0d\u6e05<\/b>\u2014\u2014\u9010\u623f\u6309\u9762\u79ef\u9009\u578b\uff0c\u5206\u9879\u6570\u636e\u4ee5\u5408\u540c\u4e0e\u5b9e\u7269\u94ed\u724c\u4e3a\u51c6\uff0c\u4e0d\u9760\u4e2d\u95f4\u8868\u683c\u63a8\u7b97\u3002<\/li>\n      <li><b>\u6015\u751f\u6d3b\u70ed\u6c34\u88ab\u8bef\u914d<\/b>\u2014\u2014\u672c\u6848\u662f\u5355\u91c7\u6696\u7089\uff0c\u53ea\u7ba1\u91c7\u6696\uff0c\u751f\u6d3b\u70ed\u6c34\u4ecd\u7531\u539f\u70ed\u6c34\u5668\u63d0\u4f9b\uff0c\u7b7e\u7ea6\u524d\u8bb2\u6e05\u695a\u3002<\/li>\n      <li><b>\u6015\u4e0d\u542b\u9879\u4e34\u65f6\u52a0\u4ef7<\/b>\u2014\u2014\u70df\u7ba1\u52a0\u957f\u3001\u5730\u652f\u67b6\u3001\u53a8\u536b\u9632\u6c34\u7b49\u4e0d\u542b\u9879\u63d0\u524d\u8bf4\u660e\u3002<\/li>\n      <li><b>\u6015\u552e\u540e\u627e\u4e0d\u5230\u4eba<\/b>\u2014\u2014\u53cc\u95e8\u5e97\u5c31\u8fd1\u54cd\u5e94\uff0c\u9690\u853d\u8282\u70b9\u5f71\u50cf\u5b58\u6863\uff0c5 \u5e74\u4f1a\u5458\u6743\u76ca\u3002<\/li>\n    <\/ul>\n  <\/div>\n  <div class=\"lm-concl\">\u2705 \u8bca\u65ad\u7ed3\u8bba\uff1a\u5df2\u88c5\u4fee\u623f + \u53ea\u89e3\u51b3\u51ac\u5b63\u91c7\u6696 + \u5c11\u52a8\u88c5\u4fee\u7684\u8bc9\u6c42\uff0c\u66f4\u4f18\u89e3\u4e0d\u662f\u5806\u9ad8\u7aef\u53cc\u4f9b\u914d\u7f6e\uff0c\u800c\u662f<b>\u66fc\u745e\u5fb7 18kW \u5355\u91c7\u6696\u7089 + \u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 4 \u7ec4<\/b>\u7684\u7cbe\u51c6\u5339\u914d\u65b9\u6848\u3002<\/div>\n<\/section>\n\n<section class=\"lm-sec\" id=\"s3\">\n  <div class=\"lm-sec-h\"><span class=\"no\">3<\/span><h2>\ud83d\udee0\ufe0f \u89e3\u51b3\u65b9\u6848\u4e0e\u914d\u7f6e\u660e\u7ec6<\/h2><\/div>\n  <div class=\"lm-card\">\n    <h3>\ud83d\udcd0 \u7cfb\u7edf\u56db\u8981\u7d20<\/h3>\n    <table class=\"lm-table\">\n      <tr><th>\u8981\u7d20<\/th><th>\u672c\u6848\u914d\u7f6e<\/th><th>\u9009\u578b\u7406\u7531<\/th><\/tr>\n      <tr class=\"hl\"><td>\u70ed\u6e90<\/td><td><a href=\"https:\/\/longmai-nt.com\/?page_id=1841\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089<\/a> N1PB18-HI.Pro <b>\u5355\u91c7\u6696\u7089<\/b> \u00d71\uff0818kW\uff09<\/td><td>\u53ea\u8d1f\u8d23\u91c7\u6696\uff0c\u5339\u914d 42.5\u33a1 \u5236\u70ed\u91cf\u9700\u6c42\uff1b\u4e0d\u4e3a\u7528\u4e0d\u4e0a\u7684\u751f\u6d3b\u70ed\u6c34\u529f\u80fd\u591a\u82b1\u94b1<\/td><\/tr>\n      <tr><td>\u672b\u7aef<\/td><td>\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 \u5171 4 \u7ec4<\/td><td>\u6c34\u5bb9\u91cf\u5c0f\u3001\u70ed\u54cd\u5e94\u5feb\uff0c\u81ea\u7136\u5bf9\u6d41\u65e0\u98ce\u611f\u3001\u8fd0\u884c\u5b89\u9759<\/td><\/tr>\n      <tr><td>\u8f93\u914d<\/td><td>\u4f1f\u661f\u94dd\u5851\u590d\u5408\u7ba1 De25 \u4e3b\u7ba1 \/ De20 \u652f\u7ba1\uff0c40\u00d780 \u5f27\u5f62\u6263\u69fd\u906e\u853d<\/td><td>\u660e\u7ba1\u8d70\u7ebf\u8d34\u5899\u89d2\uff0c\u6263\u69fd\u7f8e\u5316\uff0c\u5c3d\u91cf\u5c11\u52a8\u5df2\u88c5\u4fee<\/td><\/tr>\n      <tr><td>\u63a7\u5236<\/td><td>\u51ef\u7c73 DN15 \u4f9b\u56de\u6c34\u9600 \u00d78<\/td><td>\u5206\u7ec4\u8c03\u8282\uff0c\u5404\u7ec4\u72ec\u7acb\u53ef\u63a7<\/td><\/tr>\n    <\/table>\n  <\/div>\n  <div class=\"lm-card\">\n    <h3>\u2668\ufe0f \u9010\u623f\u914d\u7f6e\uff08\u6696\u6c14\u7247 4 \u7ec4 \u00b7 \u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea6 5,525W\uff09<\/h3>\n    <table class=\"lm-table\">\n      <tr><th>\u623f\u95f4<\/th><th>\u6696\u6c14\u7247\u914d\u7f6e<\/th><th>\u9762\u79ef \/ \u903b\u8f91<\/th><\/tr>\n      <tr class=\"hl\"><td>\u5ba2\u5385<\/td><td>\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 600\u00d71200 \u00d71<\/td><td>\u7ea614\u33a1\uff0c\u5f00\u95f4\u6700\u5927\uff0c\u5355\u7ec4\u8db3\u989d\u914d\u7f6e<\/td><\/tr>\n      <tr><td>\u9910\u5385<\/td><td>\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 600\u00d71000 \u00d71<\/td><td>\u7ea66.5\u33a1\uff0c\u6309\u9700\u914d\u7f6e\u4e0d\u8d85\u914d<\/td><\/tr>\n      <tr><td>\u4e3b\u5367<\/td><td>\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 600\u00d71200 \u00d71<\/td><td>\u7ea612\u33a1\uff0c\u8d34\u5899\u5b89\u88c5\u4e0d\u5360\u7a7a\u95f4<\/td><\/tr>\n      <tr><td>\u6b21\u5367<\/td><td>\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247 600\u00d71000 \u00d71<\/td><td>\u7ea610\u33a1\uff0c\u7cbe\u51c6\u5339\u914d<\/td><\/tr>\n    <\/table>\n    <div class=\"lm-note\">\u6309 130W\/\u33a1 \u00d7 42.5\u33a1 \u2248 5,525W \u4f30\u7b97\u603b\u8bbe\u8ba1\u5236\u70ed\u91cf\u3002\u540c\u6237\u578b\u4e0d\u540c\u671d\u5411\u3001\u4fdd\u6e29\u6761\u4ef6\u4f1a\u5f71\u54cd\u6700\u7ec8\u7247\u6570\uff0c\u9700\u4ee5\u73b0\u573a\u8d1f\u8377\u6d4b\u7b97\u4e3a\u51c6\u3002<\/div>\n  <\/div>\n  <div class=\"lm-phgrid\">\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guoluanzhuang01.jpg\" alt=\"\u672c\u6848\u5b9e\u62cd \u00b7 \u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089\u5b89\u88c5\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u66fc\u745e\u5fb7 N1PB18-HI.Pro \u5355\u91c7\u6696\u7089\u5b89\u88c5<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/tysjt-mznqxtylt.jpg\" alt=\"\u660e\u88c5\u6696\u6c14\u7cfb\u7edf\u539f\u7406\u56fe\" loading=\"lazy\"><figcaption>\u660e\u88c5\u6696\u6c14\u7cfb\u7edf\u539f\u7406\u56fe\uff08\u793a\u610f\uff09<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang01.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u6696\u6c14\u7247\u5b89\u88c5 \u2460<\/figcaption><\/figure>\n  <\/div>\n  <div class=\"lm-card\">\n    <h3>\ud83d\udccb \u8bda\u5b9e\u62ab\u9732\uff08\u8fd9\u4e9b\u8981\u5148\u8bf4\u6e05\uff09<\/h3>\n    <ul class=\"lm-ul\">\n      <li><strong>\u5355\u91c7\u6696\u7089\u4e0d\u4f9b\u751f\u6d3b\u70ed\u6c34<\/strong>\uff1a\u672c\u6848 N1PB18-HI.Pro \u53ea\u8d1f\u8d23\u91c7\u6696\uff0c\u751f\u6d3b\u70ed\u6c34\u4ecd\u7531\u539f\u6709\u70ed\u6c34\u5668\u63d0\u4f9b\uff1b\u82e5\u5e0c\u671b\u91c7\u6696\u4e0e\u70ed\u6c34\u4e00\u4f53\uff0c\u5e94\u6539\u9009\u4e24\u7528\u7089\uff0c\u7b7e\u7ea6\u524d\u5df2\u4e0e\u5ba2\u6237\u786e\u8ba4\u6e05\u695a\u3002<\/li>\n      <li><strong>\u5206\u9879\u6570\u636e\u4ee5\u5408\u540c\u4e0e\u5b9e\u7269\u4e3a\u51c6<\/strong>\uff1a\u6240\u6709\u914d\u7f6e\u4e0e\u5206\u9879\u4fe1\u606f\u4ee5\u7b7e\u7ea6\u5408\u540c\u53ca\u8bbe\u5907\u5b9e\u7269\u94ed\u724c\u4e3a\u51c6\uff0c\u4e0d\u4ee5\u4efb\u4f55\u4e2d\u95f4\u8868\u683c\u63a8\u7b97\u3002<\/li>\n      <li><strong>\u4e0d\u542b\u9879<\/strong>\uff1a\u6807\u914d\u70df\u7ba1\u957f\u5ea6\u6709\u9650\uff0c\u70df\u7ba1\u52a0\u957f\u3001\u5730\u652f\u67b6\u3001\u536b\u751f\u95f4\u4e0e\u53a8\u623f\u9632\u6c34\u3001\u975e\u6211\u65b9\u539f\u56e0\u7684\u6539\u4f4d\u4e0d\u542b\u5728\u5185\uff0c\u9700\u53e6\u884c\u786e\u8ba4\u3002<\/li>\n      <li><strong>\u660e\u88c5\u7684\u7ea6\u675f<\/strong>\uff1a\u660e\u7ba1\u5fc5\u987b\u9760\u6263\u69fd\u906e\u853d\uff0c\u9505\u7089\u6c34\u7535\u6c14\u63a5\u53e3\u9700\u8981\u4e1a\u4e3b\u914d\u5408\u9884\u7559\u5230\u4ea4\u5e95\u6307\u5b9a\u4f4d\u7f6e\uff1b\u8fd9\u4e24\u4ef6\u4e8b\u4e0d\u5230\u4f4d\uff0c\u5de5\u671f\u548c\u89c2\u611f\u90fd\u4f1a\u53d7\u5f71\u54cd\u3002<\/li>\n      <li><strong>\u8d28\u4fdd<\/strong>\uff1a\u9505\u7089\u81ea\u5b89\u88c5\u8d77 2 \u5e74\u3001\u91c7\u6696\u7ba1\u8def\u6309\u5382\u5bb6\u8d28\u4fdd\u3001\u5de5\u7a0b\u6574\u4f53 2 \u5e74\uff0c\u8d77\u7b97\u4ee5\u7ae3\u5de5\u9a8c\u6536\u7b7e\u5b57\u4e3a\u51c6\u3002<\/li>\n      <li><strong>\u4ef7\u683c\u53e3\u5f84<\/strong>\uff1a\u672c\u9875\u4e0d\u542b\u4efb\u4f55\u4ef7\u683c\u6570\u5b57\uff1b\u540c\u7c7b\u914d\u7f6e\u53ef\u53c2\u8003<a href=\"https:\/\/longmai-nt.com\/?page_id=10982\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c<\/a>\uff0c\u5177\u4f53\u91d1\u989d\u4ee5\u7b7e\u7ea6\u5408\u540c\u9501\u4ef7\u5355\u4e3a\u51c6\u3002<\/li>\n    <\/ul>\n  <\/div>\n<\/section>\n\n<section class=\"lm-sec\" id=\"s4\">\n  <div class=\"lm-sec-h\"><span class=\"no\">4<\/span><h2>\ud83d\udd28 \u65bd\u5de5\u4ea4\u4ed8\u5b9e\u62cd\u4e0e\u5de5\u827a<\/h2><\/div>\n  <div class=\"lm-card\">\n    <h3>\u9f99\u8109\u7cbe\u5de5\u8981\u70b9\uff08\u660e\u88c5\u7248\uff09<\/h3>\n    <p>\u2460 \u6cbf\u8e22\u811a\u7ebf\u3001\u5899\u89d2\u660e\u6577\u7ba1\u8def\uff0c40\u00d780 \u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u6a2a\u5e73\u7ad6\u76f4\u4e0d\u7a81\u5140\uff1b\u2461 \u4f1f\u661f\u94dd\u5851\u7ba1\u6577\u8bbe\uff0c\u53cc\u7ba1\u5f02\u7a0b\u6563\u70ed\u5747\u5300\uff1b\u2462 \u4e0d\u6253\u6d1e\u3001\u4e0d\u52a8\u5730\u9762\uff0c\u5c3d\u91cf\u5c11\u7834\u5df2\u88c5\u4fee\uff1b\u2463 \u7ba1\u8def\u6577\u8bbe\u5b8c\u6210\u540e\u505a\u6253\u538b\u8bd5\u9a8c\u5e76\u7559\u6863\uff0c\u786e\u8ba4\u65e0\u6e17\u6f0f\uff1b\u2464 \u9505\u7089\u4e0e\u56db\u7ec4\u6696\u6c14\u7247\u9010\u7ec4\u8c03\u8bd5\uff0c\u9690\u853d\u8282\u70b9\u5f71\u50cf\u5b58\u6863\u3002<\/p>\n    <div class=\"lm-note\">\ud83d\udcf7 \u4ee5\u4e0b\u4e3a<b>\u672c\u6848\u771f\u5b9e\u65bd\u5de5\u4e0e\u9a8c\u6536\u5b9e\u62cd<\/b>\uff08\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662 \u00b7 \u738b\u5973\u58eb\u5bb6\uff0c2026-11\uff09\uff1a\u7ba1\u8def\u5b89\u88c5 \u2192 \u6696\u6c14\u7247\u5b89\u88c5 \u2192 \u81ea\u52a8\u6392\u6c14\u9600 \u2192 \u7ae3\u5de5\u9a8c\u6536\uff0c\u8282\u70b9\u5f71\u50cf\u5b58\u6863\u3001\u53ef\u8ffd\u6eaf\u3002\u914d\u7f6e\u6570\u636e\u4ee5\u672c\u6848\u7b7e\u7ea6\u5408\u540c\u4e0e\u5b9e\u7269\u4e3a\u51c6\u3002<\/div>\n  <\/div>\n  <div class=\"lm-g-title\">\ud83d\udd27 \u7ba1\u8def\u5b89\u88c5\uff08\u660e\u7ba1\u6577\u8bbe + \u5f27\u5f62\u6263\u69fd\uff09<\/div>\n  <div class=\"lm-phgrid\">\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guanluanzhuang01.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ba1\u8def\u5b89\u88c5\u5b9e\u62cd \u2460\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ba1\u8def\u5b89\u88c5 \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guanluanzhuang02.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ba1\u8def\u5b89\u88c5\u5b9e\u62cd \u2461\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ba1\u8def\u5b89\u88c5 \u2461<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guanluanzhuang03.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ba1\u8def\u5b89\u88c5\u5b9e\u62cd \u2462\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ba1\u8def\u5b89\u88c5 \u2462<\/figcaption><\/figure>\n  <\/div>\n  <div class=\"lm-g-title\">\u2668\ufe0f \u6696\u6c14\u7247\u5b89\u88c5\uff08\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41 4 \u7ec4\uff09<\/div>\n  <div class=\"lm-phgrid\">\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang01.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u62cd \u2460\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u6696\u6c14\u7247\u5b89\u88c5 \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang02.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u62cd \u2461\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u6696\u6c14\u7247\u5b89\u88c5 \u2461<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang03.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u62cd \u2462\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u6696\u6c14\u7247\u5b89\u88c5 \u2462<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-nuanqipiananzhuang04.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u6696\u6c14\u7247\u5b89\u88c5\u5b9e\u62cd \u2463\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u6696\u6c14\u7247\u5b89\u88c5 \u2463<\/figcaption><\/figure>\n  <\/div>\n  <div class=\"lm-g-title\">\ud83d\udd29 \u81ea\u52a8\u6392\u6c14\u9600\u5b89\u88c5<\/div>\n  <div class=\"lm-phgrid\">\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-zidongpaiqifa01.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u81ea\u52a8\u6392\u6c14\u9600\u5b89\u88c5\u5b9e\u62cd\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u81ea\u52a8\u6392\u6c14\u9600\u5b89\u88c5 <\/figcaption><\/figure>\n  <\/div>\n  <div class=\"lm-g-title\">\u2705 \u7ae3\u5de5\u9a8c\u6536\uff082026-11 \u9a8c\u6536\u5408\u683c\uff09<\/div>\n  <div class=\"lm-phgrid\">\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou02.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ae3\u5de5\u9a8c\u6536\u5b9e\u62cd \u2460\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ae3\u5de5\u9a8c\u6536 \u2460<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou03.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ae3\u5de5\u9a8c\u6536\u5b9e\u62cd \u2461\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ae3\u5de5\u9a8c\u6536 \u2461<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou04.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ae3\u5de5\u9a8c\u6536\u5b9e\u62cd \u2462\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ae3\u5de5\u9a8c\u6536 \u2462<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou05.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ae3\u5de5\u9a8c\u6536\u5b9e\u62cd \u2463\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ae3\u5de5\u9a8c\u6536 \u2463<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou06.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ae3\u5de5\u9a8c\u6536\u5b9e\u62cd \u2464\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ae3\u5de5\u9a8c\u6536 \u2464<\/figcaption><\/figure>\n    <figure><img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-yanshou07.jpg\" alt=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u738b\u5973\u58eb\u5bb6 \u00b7 \u7ae3\u5de5\u9a8c\u6536\u5b9e\u62cd \u2465\" loading=\"lazy\"><figcaption>\u672c\u6848\u5b9e\u62cd \u00b7 \u7ae3\u5de5\u9a8c\u6536 \u2465<\/figcaption><\/figure>\n  <\/div>\n  <div class=\"lm-card\">\n    <h3>\ud83d\udd27 \u660e\u88c5\u6696\u6c14\u7247\u65bd\u5de5\u6d41\u7a0b<\/h3>\n    <div class=\"lm-steps\">\n      <div class=\"lm-step\"><span class=\"n\">\u2460<\/span><span>\u73b0\u573a\u91cf\u623f\uff1a\u786e\u8ba4\u9505\u7089\u4f4d\u3001\u56db\u7ec4\u6696\u6c14\u7247\u4f4d\u4e0e\u7ba1\u8def\u8d70\u5411<\/span><\/div>\n      <div class=\"lm-step\"><span class=\"n\">\u2461<\/span><span>\u6c34\u7535\u4ea4\u5e95\uff1a\u9505\u7089\u6c34\u7535\u6c14\u63a5\u53e3\u7531\u4e1a\u4e3b\u534f\u8c03\u9884\u7559\u5230\u6307\u5b9a\u4f4d\u7f6e<\/span><\/div>\n      <div class=\"lm-step\"><span class=\"n\">\u2462<\/span><span>\u5e03\u7ba1\u4e0e\u6263\u69fd\uff1a\u4f1f\u661f\u94dd\u5851\u7ba1\u8d70\u660e\u7ba1\uff0c\u5916\u7528\u5f27\u5f62\u6263\u69fd\u906e\u853d<\/span><\/div>\n      <div class=\"lm-step\"><span class=\"n\">\u2463<\/span><span>\u6253\u538b\u8bd5\u9a8c\uff1a\u7ba1\u8def\u6577\u8bbe\u5b8c\u6210\u540e\u6253\u538b\u5e76\u7559\u6863\uff0c\u786e\u8ba4\u65e0\u6e17\u6f0f<\/span><\/div>\n      <div class=\"lm-step\"><span class=\"n\">\u2464<\/span><span>\u5b89\u88c5\u8c03\u8bd5\uff1a\u88c5\u9505\u7089\u4e0e\u56db\u7ec4\u6696\u6c14\u7247\uff0c\u901a\u6c34\u7535\u6c14\u540e\u9010\u7ec4\u8c03\u8bd5<\/span><\/div>\n      <div class=\"lm-step\"><span class=\"n\">\u2465<\/span><span>\u7ae3\u5de5\u9a8c\u6536\uff1a2026-11-19 \u9a8c\u6536\u5408\u683c\uff0c\u8d28\u4fdd\u4e0e\u7ef4\u4fdd\u540c\u6b65\u4ea4\u4ed8<\/span><\/div>\n    <\/div>\n    <div class=\"lm-note\">\u4ece\u7b7e\u5355\u5230\u5b89\u88c5\u5b8c\u6210\u7ea6 18 \u5929\uff082026-11-11 \u7b7e\u5355 \u2192 11-17 \u5b89\u88c5\u8c03\u8bd5\u5b8c\u6210 \u2192 11-19 \u7ae3\u5de5\u9a8c\u6536\uff09\u3002\u5177\u4f53\u5de5\u671f\u4ee5\u73b0\u573a\u6761\u4ef6\u4e0e\u5408\u540c\u4e3a\u51c6\u3002<\/div>\n  <\/div>\n<\/section>\n<section class=\"lm-sec\" id=\"s5\">\n  <div class=\"lm-sec-h\"><span class=\"no\">5<\/span><h2>\ud83d\udccb \u6548\u679c\u9a8c\u8bc1\u4e0e\u5e38\u89c1\u7591\u95ee<\/h2><\/div>\n  <div class=\"lm-card\">\n    <h3>\u4ea4\u4ed8\u6548\u679c<\/h3>\n    <p>\u2460 \u5ba2\u5385\u3001\u9910\u5385\u3001\u4e3b\u5367\u3001\u6b21\u5367\u56db\u533a\u91c7\u6696\u8986\u76d6\uff0c\u6309 130W\/\u33a1 \u8bbe\u8ba1\u3001\u603b\u5236\u70ed\u91cf\u7ea6 5,525W\uff0c\u6ee1\u8db3\u51ac\u5b63\u8212\u9002\u5ba4\u6e29\u76ee\u6807\uff1b\u2461 \u81ea\u7136\u5bf9\u6d41\u6563\u70ed\u65e0\u98ce\u611f\u3001\u8fd0\u884c\u5b89\u9759\uff1b\u2462 \u660e\u7ba1\u8d70\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u6a2a\u5e73\u7ad6\u76f4\u8d34\u5408\u5899\u89d2\uff0c\u5c3d\u91cf\u5c11\u52a8\u5df2\u5b8c\u6210\u88c5\u4fee\uff1b\u2463 \u6253\u538b\u8bd5\u9a8c\u5408\u683c\u3001\u9690\u853d\u8282\u70b9\u7559\u6863\uff0c2026-11-19 \u7ae3\u5de5\u9a8c\u6536\u5408\u683c\u5e76\u4ea4\u4ed8\u8d28\u4fdd\u3002\u672c\u6848\u518d\u6b21\u9a8c\u8bc1\uff1a<b>\u628a\u914d\u7f6e\u914d\u51c6\uff0c\u6bd4\u628a\u914d\u7f6e\u5806\u9ad8\u66f4\u80fd\u8d62\u5f97\u4fe1\u4efb\u3002<\/b><\/p>\n  <\/div>\n  <div class=\"lm-card\">\n    <h3>\u2753 \u9ad8\u9891\u95ee\u7b54<\/h3>\n    <dl class=\"lm-faq\">\n      <dt>\u660e\u88c5\u6696\u6c14\u7247\u4f1a\u7834\u574f\u5df2\u88c5\u4fee\u7684\u623f\u5b50\u5417\uff1f<\/dt>\n      <dd>\u660e\u88c5\u91c7\u7528\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247\uff0c\u7ba1\u8def\u8d70\u660e\u7ba1\u5e76\u7528\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u4e0d\u6253\u6d1e\u3001\u4e0d\u52a8\u5730\u9762\uff0c\u5bf9\u73b0\u6709\u88c5\u4fee\u7834\u574f\u8f83\u5c0f\uff0c\u9002\u5408\u5df2\u88c5\u4fee\u623f\u5feb\u901f\u91c7\u6696\u3002<\/dd>\n      <dt>\u66fc\u745e\u5fb7\u5355\u91c7\u6696\u7089\u540c\u65f6\u89e3\u51b3\u751f\u6d3b\u70ed\u6c34\u5417\uff1f<\/dt>\n      <dd>\u672c\u6848\u4e3a\u5355\u91c7\u6696\u7089\uff08N1PB18-HI.Pro\uff09\uff0c\u4ec5\u8d1f\u8d23\u91c7\u6696\uff1b\u751f\u6d3b\u70ed\u6c34\u7531\u539f\u6709\u70ed\u6c34\u5668\u63d0\u4f9b\u3002\u82e5\u9700\u91c7\u6696\u4e0e\u70ed\u6c34\u4e00\u4f53\uff0c\u5e94\u9009\u4e24\u7528\u7089\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u65b9\u6848\u4e3a\u51c6\u3002<\/dd>\n      <dt>\u5df2\u88c5\u4fee\u623f\u505a\u660e\u88c5\u6696\u6c14\uff0c\u54ea\u4e9b\u4e8b\u8981\u63d0\u524d\u5b9a\uff1f<\/dt>\n      <dd>\u660e\u88c5\u8d70\u660e\u7ba1\u9700\u8981\u6263\u69fd\u906e\u853d\uff0c\u9505\u7089\u6c34\u7535\u6c14\u63a5\u53e3\u8981\u7531\u4e1a\u4e3b\u534f\u8c03\u9884\u7559\u5230\u4ea4\u5e95\u6307\u5b9a\u4f4d\u7f6e\uff1b\u6807\u914d\u70df\u7ba1\u957f\u5ea6\u6709\u9650\uff0c\u52a0\u957f\u70df\u7ba1\u3001\u5730\u652f\u67b6\u3001\u536b\u751f\u95f4\u4e0e\u53a8\u623f\u9632\u6c34\u7b49\u9700\u53e6\u884c\u786e\u8ba4\u3002<\/dd>\n      <dt>\u600e\u4e48\u9884\u7ea6\u540c\u6237\u578b\u52d8\u6d4b\u4e0e\u914d\u7f6e\u53c2\u8003\uff1f<\/dt>\n      <dd>\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\uff0c\u81f4\u7535<a href=\"tel:15828489188\">15828489188<\/a>\uff08\u9ec4\u52c7\uff09\u5373\u53ef\u9884\u7ea6\uff0c\u83b7\u53d6\u540c\u6237\u578b\u7684\u914d\u7f6e\u53c2\u8003\u4e0e\u5206\u9879\u8bf4\u660e\u3002<\/dd>\n    <\/dl>\n  <\/div>\n  <div class=\"lm-rel\">\n    <h3>\u5ef6\u4f38\u9605\u8bfb \u00b7 \u6696\u6c14\u7247\u7cfb\u7edf\u6743\u5a01\u8d44\u6599<\/h3>\n    <div class=\"lm-links\">\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=12447\"><span class=\"t\">\u6696\u6c14\u7247\u7cfb\u7edf\u767d\u76ae\u4e66<\/span><span class=\"d\">\u7cfb\u7edf\u539f\u7406\u4e0e\u9009\u578b\u4f9d\u636e\uff0c\u7406\u89e3\u660e\u88c5\u6696\u6c14\u7684\u8bbe\u8ba1\u903b\u8f91<\/span><\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2137\"><span class=\"t\">\u6696\u6c14\u7247\u77e5\u8bc6\u5e95\u5ea7<\/span><span class=\"d\">\u5e38\u89c1\u7591\u95ee\u4e0e\u672f\u8bed\u89e3\u91ca\uff0c\u4fbf\u4e8e\u5bf9\u7167\u672c\u6848\u914d\u7f6e<\/span><\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=10982\"><span class=\"t\">\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u4ef7\u683c<\/span><span class=\"d\">\u540c\u7c7b\u914d\u7f6e\u7684\u6784\u6210\u4e0e\u4ef7\u683c\u53e3\u5f84\u53c2\u8003<\/span><\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2297\"><span class=\"t\">\u5ba2\u6237\u6848\u4f8b\u4e2d\u5fc3<\/span><span class=\"d\">\u66f4\u591a\u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b\uff0c\u6309\u6237\u578b\u4e0e\u7cfb\u7edf\u7c7b\u578b\u67e5\u9605<\/span><\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"lm-sec\" id=\"stores\">\n  <div class=\"lm-sec-h\"><span class=\"no\">\ud83d\udccd<\/span><h2>\u95e8\u5e97\u4e0e\u670d\u52a1<\/h2><\/div>\n  <div class=\"lm-stores\">\n    <div class=\"lm-store\">\n      <div class=\"nm\">\u5317\u5bcc\u68ee\u95e8\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-beifusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5317\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n      <div class=\"ln\">\u7535\u8bdd <a href=\"tel:02865272586\">028-65272586<\/a><\/div>\n      <a class=\"amap\" href=\"https:\/\/uri.amap.com\/search?keyword=\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5317\u95e8\u5e97&city=510100\" target=\"_blank\" rel=\"noopener\">\ud83d\udccd \u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a<\/a>\n    <\/div>\n    <div class=\"lm-store\">\n      <div class=\"nm\">\u5357\u5bcc\u68ee\u95e8\u5e97<\/div>\n      <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/07\/gw-lmnt-nanfusen-store.jpg\" alt=\"\u9f99\u8109\u6696\u901a\u5357\u5bcc\u68ee\u95e8\u5e97\u5b9e\u666f\" loading=\"lazy\">\n      <div class=\"ln\">\u7535\u8bdd <a href=\"tel:02886131795\">028-86131795<\/a><\/div>\n      <a class=\"amap\" href=\"https:\/\/uri.amap.com\/search?keyword=\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5357\u95e8\u5e97&city=510100\" target=\"_blank\" rel=\"noopener\">\ud83d\udccd \u9ad8\u5fb7\u4e00\u952e\u5bfc\u822a<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"lm-note\">\u52d8\u6d4b\u3001\u552e\u540e\u4e0e\u8d28\u4fdd\u7edf\u4e00\u7531\u65b9\u6848\u987e\u95ee\u9ec4\u52c7\u5bf9\u63a5\uff082004 \u5e74\u8d77\u6df1\u8015\u6696\u901a\uff09\uff0c\u4ece\u52d8\u6d4b\u5230\u9a8c\u6536\u5168\u7a0b\u8ddf\u8fdb\uff0c\u9500\u552e\u76f4\u8054 <a href=\"tel:15828489188\">15828489188<\/a>\u3002<\/div>\n<\/section>\n\n<div class=\"lm-cta\">\n  <h2>\ud83d\udcde \u514d\u8d39\u83b7\u53d6\u4f60\u5bb6\u7684\u660e\u88c5\u6696\u6c14\u65b9\u6848<\/h2>\n  <p>\u514d\u8d39\u4e0a\u95e8\u51b7\u70ed\u8d1f\u8377\u52d8\u6d4b \u2192 \u9010\u623f\u914d\u7f6e\u9009\u578b \u2192 \u4ef7\u683c\u53e3\u5f84\u6e05\u6670 \u2192 \u7cbe\u5de5\u5b89\u88c5 \u00b7 \u6210\u90fd\u5168\u57df\u5747\u53ef\u9884\u7ea6<\/p>\n  <a class=\"lm-btn\" href=\"tel:15828489188\">\ud83d\udcde \u514d\u8d39\u52d8\u6d4b 15828489188<\/a>\n  <a class=\"lm-btn o\" href=\"tel:02886131795\">\ud83c\udfd7\ufe0f \u9884\u7ea6\u53c2\u89c2\u5728\u5efa\u5de5\u5730<\/a>\n<\/div>\n\n<section class=\"lm-sec\" id=\"links\">\n  <div class=\"lm-rel\">\n    <h3>\ud83d\udd17 \u5173\u8054\u9605\u8bfb<\/h3>\n    <div class=\"lm-links\">\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=5556\"><span class=\"t\">\u6696\u6c14\u7247\u6848\u4f8b\u4e2d\u5fc3<\/span><span class=\"d\">\u66f4\u591a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b<\/span><\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=2137\"><span class=\"t\">\u6696\u6c14\u7247\u7cfb\u7edf\u77e5\u8bc6\u5e95\u5ea7<\/span><span class=\"d\">\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u7247\u539f\u7406\u4e0e\u9002\u7528\u573a\u666f\u8bf4\u660e<\/span><\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=1841\"><span class=\"t\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u4ea7\u54c1\u9875<\/span><span class=\"d\">\u672c\u6848\u70ed\u6e90\u54c1\u724c\u7684\u4ea7\u54c1\u7ebf\u4e0e\u578b\u53f7\u8d44\u6599<\/span><\/a>\n      <a class=\"lm-link-card\" href=\"https:\/\/longmai-nt.com\/?page_id=625\"><span class=\"t\">\u670d\u52a1\u4fdd\u969c<\/span><span class=\"d\">\u52d8\u6d4b\u3001\u5b89\u88c5\u3001\u9a8c\u6536\u4e0e\u8d28\u4fdd\u670d\u52a1\u8bf4\u660e<\/span><\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n<div class=\"lm-foot\">\u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\uff082004 \u5e74\u8d77\uff0c20 \u4f59\u5e74\u6696\u901a\u8001\u5e97\uff09\uff5c \u672c\u6587\u4e3a\u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b\uff0c\u914d\u7f6e\u4e0e\u5de5\u827a\u63cf\u8ff0\u5747\u57fa\u4e8e\u5b9e\u9645\u65bd\u5de5\uff1b\u4e0d\u542b\u4ef7\u683c\u6570\u5b57\uff0c\u5177\u4f53\u4ee5\u73b0\u573a\u52d8\u6d4b\u4e0e\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6\u3002<br>\u65b9\u6848\u987e\u95ee\uff1a\u9ec4\u52c7\uff08\u5317\u5bcc\u68ee\u95e8\u5e97 \u00b7 2004 \u5e74\u8d77\u6df1\u8015\u6696\u901a\uff09\uff5c \u9500\u552e\u76f4\u8054 <a href=\"tel:15828489188\">15828489188<\/a><\/div>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u771f\u5b9e\u4ea4\u4ed8\u6848\u4f8b \u5df2\u88c5\u4fee\u623f\u4e0d\u52a8 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-20906","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u8001\u623f\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u6cbf\u5899\u660e\u6577\u3001\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea65525W\uff0c\u56db\u533a\u51ac\u5b6318~22\u2103\u3002\u9644\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u62cd\u4e0e\u5355\u7089\u4e0d\u4f9b\u70ed\u6c34\u7b49\u8bda\u5b9e\u62ab\u9732\uff0c\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=20906\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u8001\u623f\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u6cbf\u5899\u660e\u6577\u3001\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea65525W\uff0c\u56db\u533a\u51ac\u5b6318~22\u2103\u3002\u9644\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u62cd\u4e0e\u5355\u7089\u4e0d\u4f9b\u70ed\u6c34\u7b49\u8bda\u5b9e\u62ab\u9732\uff0c\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=20906\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T03:18:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guoluanzhuang01.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906\",\"name\":\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/gw-dzkddey-guoluanzhuang01.jpg\",\"datePublished\":\"2026-11-20T07:12:44+00:00\",\"dateModified\":\"2026-11-21T03:18:25+00:00\",\"description\":\"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u8001\u623f\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u6cbf\u5899\u660e\u6577\u3001\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea65525W\uff0c\u56db\u533a\u51ac\u5b6318~22\u2103\u3002\u9644\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u62cd\u4e0e\u5355\u7089\u4e0d\u4f9b\u70ed\u6c34\u7b49\u8bda\u5b9e\u62ab\u9732\uff0c\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/gw-dzkddey-guoluanzhuang01.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/gw-dzkddey-guoluanzhuang01.jpg\",\"width\":995,\"height\":1327},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20906#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a","description":"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u8001\u623f\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u6cbf\u5899\u660e\u6577\u3001\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea65525W\uff0c\u56db\u533a\u51ac\u5b6318~22\u2103\u3002\u9644\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u62cd\u4e0e\u5355\u7089\u4e0d\u4f9b\u70ed\u6c34\u7b49\u8bda\u5b9e\u62ab\u9732\uff0c\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=20906","og_locale":"zh_CN","og_type":"article","og_title":"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a","og_description":"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u8001\u623f\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u6cbf\u5899\u660e\u6577\u3001\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea65525W\uff0c\u56db\u533a\u51ac\u5b6318~22\u2103\u3002\u9644\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u62cd\u4e0e\u5355\u7089\u4e0d\u4f9b\u70ed\u6c34\u7b49\u8bda\u5b9e\u62ab\u9732\uff0c\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=20906","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-21T03:18:25+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guoluanzhuang01.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"7 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=20906","url":"https:\/\/longmai-nt.com\/?page_id=20906","name":"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=20906#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=20906#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guoluanzhuang01.jpg","datePublished":"2026-11-20T07:12:44+00:00","dateModified":"2026-11-21T03:18:25+00:00","description":"\u6210\u90fd\u7535\u5b50\u79d1\u5927\u7247\u533a\u5df2\u88c5\u4fee\u623f\u660e\u88c5\u6696\u6c14\u7247\u771f\u5b9e\u6848\u4f8b\uff1a42.5\u33a1\u8001\u623f\u4e0d\u52a8\u5730\u9762\uff0c\u66fc\u745e\u5fb718kW\u5355\u91c7\u6696\u7089\u914d\u6d3e\u6d1b\u5229\u81ea\u7136\u5bf9\u6d41\u6696\u6c14\u72474\u7ec4\uff0c\u4f1f\u661f\u94dd\u5851\u7ba1\u6cbf\u5899\u660e\u6577\u3001\u5f27\u5f62\u6263\u69fd\u906e\u853d\uff0c\u8bbe\u8ba1\u5236\u70ed\u91cf\u7ea65525W\uff0c\u56db\u533a\u51ac\u5b6318~22\u2103\u3002\u9644\u771f\u5b9e\u65bd\u5de5\u9a8c\u6536\u5b9e\u62cd\u4e0e\u5355\u7089\u4e0d\u4f9b\u70ed\u6c34\u7b49\u8bda\u5b9e\u62ab\u9732\uff0c\u6210\u90fd\u5168\u57df\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=20906#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=20906"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=20906#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guoluanzhuang01.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/11\/gw-dzkddey-guoluanzhuang01.jpg","width":995,"height":1327},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=20906#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u7535\u5b50\u79d1\u5927\u4e1c\u4e8c\u9662\u00b7\u738b\u5973\u58eb\u5bb6\u660e\u88c5\u6696\u6c14\u7247\u4ea4\u4ed8\u6848\u4f8b"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20906"}],"version-history":[{"count":3,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20906\/revisions"}],"predecessor-version":[{"id":20953,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20906\/revisions\/20953"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}