{"id":20914,"date":"2026-11-20T16:22:29","date_gmt":"2026-11-20T08:22:29","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=20914"},"modified":"2026-11-20T16:22:30","modified_gmt":"2026-11-20T08:22:30","slug":"%e5%a4%a9%e6%b0%9f%e5%9c%b0%e6%b0%b4%e4%b8%bb%e7%ae%a1%e4%b8%ba%e4%bb%80%e4%b9%88%e6%af%94%e5%a3%81%e6%8c%82%e7%82%89%e7%b2%97%ef%bc%9f%e6%b8%a9%e5%b7%ae%e3%80%81%e6%b5%81%e9%87%8f%e3%80%81%e7%ae%a1","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=20914","title":{"rendered":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05"},"content":{"rendered":"<style>\n.lmnt-body{font-family:-apple-system,\"PingFang SC\",\"Microsoft YaHei\",sans-serif;color:#2b2b2b;line-height:1.75;font-size:16px;}\n.lmnt-body h2{color:#1a3a6e;font-size:21px;line-height:1.4;border-bottom:2px solid #e3e8f0;padding-bottom:6px;margin:30px 0 14px;}\n.lmnt-body h3{color:#243b5e;font-size:17px;line-height:1.5;margin:22px 0 8px;}\n.lmnt-body p{margin:13px 0;}\n.lmnt-body b{color:#1a3a6e;}\n.lmnt-body a{color:#1a5fb4;text-decoration:underline;}\n.lmnt-body ul{padding-left:22px;margin:13px 0;}\n.lmnt-body li{margin:7px 0;}\n.lmnt-body .lmnt-blockquote{border-left:4px solid #1a3a6e;background:#f5f7fb;padding:14px 18px;margin:16px 0;color:#243b5e;border-radius:0 6px 6px 0;}\n.lmnt-body .lmnt-table{width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;}\n.lmnt-body .lmnt-table th,.lmnt-body .lmnt-table td{border:1px solid #dde3ec;padding:8px 10px;text-align:left;vertical-align:top;line-height:1.65;}\n.lmnt-body .lmnt-table th{background:#eef3fb;color:#1a3a6e;font-weight:600;}\n.lmnt-body .lmnt-table td{color:#2b2b2b;}\n@media(max-width:600px){.lmnt-body{font-size:15px;}.lmnt-body h2{font-size:19px;}.lmnt-body .lmnt-table{font-size:13.5px;}}\n<\/style>\n<div class=\"lm-geo\" data-layer=\"\u679d\" data-book=\"NT03\" data-cat=\"\u4e24\u8054\u4f9b\" data-code=\"NT03-02-002\" data-step=\"2\" data-face=\"\u5206\u6790\" data-elem=\"\u8f93\u914d\" data-q=\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\"><\/div>\n<div class=\"lmnt-body\">\n<h2 class=\"lmnt-h2\">\u5ba2\u6237\u539f\u8bdd<\/h2>\n<p>\u300a\u5730\u6696\u4e3b\u7ba1\uff0c\u4e3a\u4ec0\u4e48\u4e3b\u673a\u8d8a\u5c0f\u53cd\u800c\u8d8a\u7c97\u300b\u2014\u2014\u8fd9\u662f\u65e5\u7acb\u667a\u4eab\u6e20\u9053\u5de5\u7a0b\u5e08\u5199\u63a8\u6587\u65f6\u7528\u7684\u6807\u9898\u3002\u6807\u9898\u80fd\u6210\u7acb\uff0c\u662f\u56e0\u4e3a\u5b83\u662f\u5ba2\u6237\u62ff\u7740\u4e24\u5957\u65b9\u6848\u6bd4\u4ef7\u65f6\u771f\u7684\u4f1a\u649e\u4e0a\u7684\u90a3\u9053\u574e\uff1a<\/p>\n<blockquote class=\"lmnt-blockquote\">\n<p>\u300c\u4e24\u8054\u4f9b\u65b9\u6848\u56fe\u4e0a\u4e3b\u7ba1\u6807\u7740 De40\u3001De50\uff0c\u9694\u58c1\u58c1\u6302\u7089\u65b9\u6848\u624d De32\u2014\u2014\u662f\u4e0d\u662f\u7ba1\u6750\u591a\u7ed9\u6211\u4eec\u7b97\u94b1\u4e86\uff1f\u300d<\/p>\n<\/blockquote>\n<p>\u6bd4\u4ef7\u6bd4\u5230\u7ba1\u6750\u8fd9\u4e00\u5c42\u7684\u5ba2\u6237\uff0c\u95ee\u9898\u5f80\u5f80\u5148\u843d\u5728\u8fd9\u91cc\u3002\u8fd9\u4e00\u9875\u628a\u8fd9\u7b14\u8d26\u644a\u5f00\u7b97\uff1a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e09\u4e2a\u6570\u600e\u4e48\u4e92\u76f8\u7275\u4f4f\uff0c\u4e24\u8054\u4f9b\u548c\u58c1\u6302\u7089\u5404\u6309\u4ec0\u4e48\u53e3\u5f84\uff0c\u56fe\u7eb8\u8be5\u600e\u4e48\u6807\uff0c\u88c5\u5b8c\u600e\u4e48\u81ea\u5df1\u67e5\u3002<\/p>\n<h2 class=\"lmnt-h2\">\u5b9a\u4e49\uff1a\u8fd9\u5230\u5e95\u662f\u4ec0\u4e48\u95ee\u9898<\/h2>\n<p>\u5148\u628a\u4e09\u4e2a\u6570\u7684\u5173\u7cfb\u4e00\u53e5\u8bdd\u8bf4\u6b7b\uff1a<b>\u70ed\u91cf \uff1d \u6d41\u91cf \u00d7 1.163 \u00d7 \u4f9b\u56de\u6c34\u6e29\u5dee\u3002<\/b>1.163 \u662f\u6c34\u7684\u70ed\u5bb9\u6362\u7b97\uff1a\u6bcf\u5c0f\u65f6 1 \u7acb\u65b9\u7c73\u7684\u6c34\uff0c\u6e29\u5ea6\u62c9\u4f4e 1\u2103\uff0c\u642c\u8fd0\u8d70\u7684\u70ed\u91cf\u7ea6 1.163 \u5343\u74e6\u3002\u6240\u4ee5\u540c\u6837\u4e00\u680b\u623f\u5b50\u7684\u91c7\u6696\u70ed\u91cf\uff0c\u6e29\u5dee\u5927\uff0c\u6c34\u53ef\u4ee5\u6d41\u5f97\u6162\uff1b\u6e29\u5dee\u5c0f\uff0c\u6c34\u5c31\u5fc5\u987b\u6d41\u5f97\u5feb\u2014\u2014\u6d41\u91cf\u4e00\u5927\uff0c\u7ba1\u5b50\u5c31\u5f97\u7c97\u3002<b>\u7ba1\u5f84\u7c97\u7ec6\u4e0d\u662f\u770b\u4e3b\u673a\u5927\u5c0f\uff0c\u662f\u770b\u8981\u642c\u591a\u5c11\u6c34\u3002<\/b><\/p>\n<p>\u4e3b\u673a\u53cd\u800c\u300c\u8d8a\u5c0f\u8d8a\u7c97\u300d\uff0c\u8bf4\u7684\u5c31\u662f\u8fd9\u4e2a\u53cd\u5dee\uff1a\u58c1\u6302\u7089\u70e7\u71c3\u6c14\uff0c\u51fa\u6c34\u6e29\u5ea6\u9ad8\uff0c\u5141\u8bb8\u6e29\u5dee\u5927\uff0c\u6c34\u5c11\u6d41\u70b9\u4e5f\u80fd\u628a\u70ed\u91cf\u9001\u5230\uff1b\u4e24\u8054\u4f9b\u4e3b\u673a\u662f\u7a7a\u6c14\u6e90\u70ed\u6cf5\uff0c\u5730\u6696\u4f9b\u6c34\u8d70\u4f4e\u6e29\uff0845\u2103 \u6863\uff09\uff0c\u6e29\u5dee\u88ab\u538b\u5f97\u5f88\u5c0f\uff0c\u540c\u6837\u70ed\u91cf\u53ea\u80fd\u9760\u6d41\u91cf\u5806\u51fa\u6765\u3002\u4e3b\u673a\u529f\u7387\u6ca1\u53d8\u5927\uff0c\u7ba1\u5b50\u5374\u8981\u66f4\u7c97\u2014\u2014\u4e0d\u662f\u7ba1\u6750\u591a\u7b97\u94b1\uff0c\u662f\u6c34\u7684\u642c\u8fd0\u91cf\u7ffb\u4e86\u500d\u3002<\/p>\n<h2 class=\"lmnt-h2\">\u5206\u6790\uff1a\u4e24\u8054\u4f9b\u7684\u6e29\u5dee\u4e3a\u4ec0\u4e48\u53ea\u6709 5\u2103<\/h2>\n<p>\u4e24\u8054\u4f9b\u5730\u6696\u7684\u6e29\u5dee\u6709\u5b98\u65b9\u51fa\u5904\u3002\u65e5\u7acb\u6210\u90fd\u5206\u516c\u53f8 2024 \u5e74 1 \u6708\u53d1\u7ed9\u7ecf\u9500\u5546\u7684\u6280\u672f\u901a\u77e5\uff08\u7f16\u53f7 HH-CD-TZ-JS0001\uff09\uff0c\u6574\u5f20\u6c34\u8def\u4e3b\u7ba1\u9009\u578b\u8868\u7684\u8ba1\u7b97\u6761\u4ef6\u5199\u6b7b\uff1a<b>\u4f9b\u56de\u6c34\u6e29\u5ea6 45\/40\u2103<\/b>\u2014\u2014\u6e29\u5dee 5\u2103\u3002\u62ff\u667a\u4eab SET-FREE \u6574\u4f53\u5f0f\u5929\u6c1f\u70ed\u6c34\u56db\u6863\u673a\u578b\u7684\u989d\u5b9a\u53c2\u6570\u53cd\u63a8\uff0c\u7ed3\u679c\u5b8c\u5168\u5bf9\u4e0a\uff1a<\/p>\n<table class=\"lmnt-table\">\n<thead>\n<tr>\n<th>\u667a\u4eab\u673a\u578b<\/th>\n<th>\u5730\u6696\u989d\u5b9a\u6c34\u6d41\u91cf<\/th>\n<th>\u989d\u5b9a\u5236\u70ed\u91cf<\/th>\n<th>\u53cd\u63a8\u6e29\u5dee<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>RAS-224FSPUNYQ<\/td>\n<td>4.3 m\u00b3\/h<\/td>\n<td>25.0 kW<\/td>\n<td>\u7ea6 5.0\u2103<\/td>\n<\/tr>\n<tr>\n<td>RAS-240FSPUNYQ<\/td>\n<td>4.5 m\u00b3\/h<\/td>\n<td>26.0 kW<\/td>\n<td>\u7ea6 5.0\u2103<\/td>\n<\/tr>\n<tr>\n<td>RAS-280FSPUNYQ<\/td>\n<td>5.4 m\u00b3\/h<\/td>\n<td>31.5 kW<\/td>\n<td>\u7ea6 5.0\u2103<\/td>\n<\/tr>\n<tr>\n<td>RAS-320FSPUNYQ<\/td>\n<td>5.8 m\u00b3\/h<\/td>\n<td>34.0 kW<\/td>\n<td>\u7ea6 5.0\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u56db\u6863\u673a\u578b\u5168\u90e8\u843d\u5728 5\u2103\uff0c\u4e0d\u662f\u5de7\u5408\u2014\u2014\u6280\u672f\u901a\u77e5\u9009\u578b\u8868\u5c31\u662f\u6309\u8fd9\u4e2a\u53e3\u5f84\u7b97\u51fa\u6765\u7684\u3002\u518d\u770b\u58c1\u6302\u7089\u8fd9\u8fb9\uff1a\u58c1\u6302\u7089\u5e26\u6696\u6c14\u7247\uff0c\u51fa\u6c34\u6e29\u5ea6\u9ad8\uff0c\u7ba1\u5f84\u548c\u6d41\u91cf\u7684\u8d26\u6309 <b>20\u2103 \u6e29\u5dee<\/b>\u6765\u7b97\uff08\u8fd9\u4e2a\u6570\u6765\u81ea\u6211\u4eec\u81ea\u5df1\u7684\u65b9\u6848\u4e66\u70ed\u8d1f\u8377\u6d4b\u7b97\uff1aDe25 \u4e3b\u7ba1\u6700\u5927\u6d41\u91cf\u7ea6 500L\/h\uff0c20\u2103 \u6e29\u5dee\u4e0b\u70ed\u4f20\u8f93\u80fd\u529b\u7ea6 11.6 \u5343\u74e6\uff09\u3002\u628a\u4e24\u4e2a\u53e3\u5f84\u5e76\u6392\u653e\uff1a<\/p>\n<table class=\"lmnt-table\">\n<thead>\n<tr>\n<th>\u540c\u6837 10 \u5343\u74e6\u70ed\u91cf<\/th>\n<th>\u6309 5\u2103 \u6e29\u5dee\uff08\u4e24\u8054\u4f9b\u5730\u6696\uff09<\/th>\n<th>\u6309 20\u2103 \u6e29\u5dee\uff08\u58c1\u6302\u7089\u5e26\u6696\u6c14\u7247\uff09<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u9700\u8981\u6d41\u91cf<\/td>\n<td>\u7ea6 1.72 m\u00b3\/h<\/td>\n<td>\u7ea6 0.43 m\u00b3\/h<\/td>\n<\/tr>\n<tr>\n<td>\u500d\u6570<\/td>\n<td colspan=\"2\">\u4e24\u8054\u4f9b\u7684\u6d41\u91cf\u662f\u58c1\u6302\u7089\u53e3\u5f84\u7684 4 \u500d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u6d41\u91cf\u5dee\u56db\u500d\uff0c\u7ba1\u5f84\u81ea\u7136\u62c9\u5f00\u4e00\u6863\u5230\u4e24\u6863\u3002\u8fd9\u5c31\u662f\u300c\u4e3b\u673a\u8d8a\u5c0f\u53cd\u800c\u8d8a\u7c97\u300d\u7684\u5168\u90e8\u5e95\u8d26\u3002<\/p>\n<h2 class=\"lmnt-h2\">\u8bca\u65ad\uff1a\u7ba1\u5f84\u600e\u4e48\u5b9a\u3001\u56fe\u7eb8\u600e\u4e48\u6807\u3001\u88c5\u5b8c\u600e\u4e48\u67e5<\/h2>\n<h3>\u7b2c\u4e00\uff0c\u7ba1\u5f84\u6309\u5b98\u65b9\u9009\u578b\u8868\u5b9a<\/h3>\n<p>\u6280\u672f\u901a\u77e5\u6309\u65b0\u884c\u4e1a\u6807\u51c6\uff08\u5e73\u5747\u6bd4\u6469\u963b 100~200Pa\/m\uff09\u3001PPR \u7ba1 S5 \u7cfb\u5217\u3001\u4f9b\u56de\u6c34 45\/40\u2103 \u7b97\u51fa\u8fd9\u5f20\u5bf9\u7167\u8868\uff1a<\/p>\n<table class=\"lmnt-table\">\n<thead>\n<tr>\n<th>S5 \u7ba1\u5f84<\/th>\n<th>\u5185\u5f84<\/th>\n<th>\u901a\u8fc7\u6d41\u91cf<\/th>\n<th>\u5bf9\u5e94\u70ed\u91cf<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>De25<\/td>\n<td>20.4 mm<\/td>\n<td>0.4~0.7 m\u00b3\/h<\/td>\n<td>2.3~4 kW<\/td>\n<\/tr>\n<tr>\n<td>De32<\/td>\n<td>26.2 mm<\/td>\n<td>0.7~1.3 m\u00b3\/h<\/td>\n<td>4~7.5 kW<\/td>\n<\/tr>\n<tr>\n<td>De40<\/td>\n<td>32.6 mm<\/td>\n<td>1.3~2.3 m\u00b3\/h<\/td>\n<td>7.5~13.3 kW<\/td>\n<\/tr>\n<tr>\n<td>De50<\/td>\n<td>40.8 mm<\/td>\n<td>2.3~4.1 m\u00b3\/h<\/td>\n<td>13.3~23.6 kW<\/td>\n<\/tr>\n<tr>\n<td>De63<\/td>\n<td>51.4 mm<\/td>\n<td>4.1~7.6 m\u00b3\/h<\/td>\n<td>23.6~43.8 kW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u843d\u5230\u5177\u4f53\u673a\u578b\uff0c\u901a\u77e5\u91cc\u7ed9\u4e86\u660e\u786e\u7ed3\u8bba\uff08S5 \u7cfb\u5217\uff09\uff1a<\/p>\n<table class=\"lmnt-table\">\n<thead>\n<tr>\n<th>\u667a\u4eab\/\u6c34\u6a21\u5757\u673a\u578b<\/th>\n<th>\u4e3b\u7ba1\u7ba1\u5f84<\/th>\n<th>\u4f9b\u56de\u4e3b\u7ba1\u603b\u957f\u5ea6\u4e0a\u9650<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>RAS-100FSPUNQ<\/td>\n<td>De40\u00d73.7mm<\/td>\n<td>\u226490 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-125FSPUNQ<\/td>\n<td>De50\u00d74.6mm<\/td>\n<td>\u2264200 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-140FSPUNQ<\/td>\n<td>De50\u00d74.6mm<\/td>\n<td>\u2264140 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-160FSPUNQ<\/td>\n<td>De50\u00d74.6mm<\/td>\n<td>\u2264260 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-200FSPUNQ<\/td>\n<td>De50\u00d74.6mm<\/td>\n<td>\u2264170 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-224FSPUNYQ<\/td>\n<td>De63\u00d75.8mm<\/td>\n<td>\u2264580 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-280FSPUNYQ<\/td>\n<td>De63\u00d75.8mm<\/td>\n<td>\u2264290 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>RAS-320FSPUNYQ<\/td>\n<td>De63\u00d75.8mm<\/td>\n<td>\u2264240 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6a21\u5757 RWMG-160\/200FWNZ1Q<\/td>\n<td>De50\u00d74.6mm<\/td>\n<td>\u2264390~650 \u7c73<\/td>\n<\/tr>\n<tr>\n<td>\u6c34\u6a21\u5757 RWMG-280\/335FWNZ1Q<\/td>\n<td>De63\u00d75.8mm<\/td>\n<td>\u2264330~620 \u7c73<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u7b2c\u4e8c\uff0c\u56fe\u7eb8\u6807\u6ce8\u5fc5\u987b\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50<\/h3>\n<p>\u6280\u672f\u901a\u77e5\u539f\u6587\u8981\u6c42\uff1a\u6c34\u8def\u7ba1\u9053\u7684\u7ba1\u5f84\u6807\u6ce8\uff0c\u5fc5\u987b\u6807\u660e\u7ba1\u5f84\u7cfb\u5217\u3001\u5927\u5c0f\u53ca\u58c1\u539a\uff0c\u5199\u6210<b>\u300cS5 \u7cfb\u5217\uff0cDe40\u00d73.7mm\u300d<\/b>\u8fd9\u6837\uff1b\u53ea\u5199\u4e00\u4e2a De40 \u4e0d\u7b97\u6570\u3002\u539f\u56e0\u5f88\u5b9e\u5728\uff1a\u540c\u4e3a De40 \u5916\u5f84\uff0cS5 \u58c1\u539a 3.7mm\u3001\u5185\u5f84 32.6mm\uff0cS3.2 \u58c1\u539a 5.5mm\u3001\u5185\u5f84\u53ea\u6709 29.0mm\u2014\u2014\u58c1\u539a\u5dee\u4e00\u6863\uff0c\u5185\u5f84\u5dee 3.6mm\uff0c\u540c\u4e00\u5f20\u6d41\u91cf\u8868\u5957\u4e0a\u53bb\u5c31\u662f\u4e24\u79cd\u7ed3\u679c\u3002\u5ba1\u56fe\u7684\u65f6\u5019\u770b\u5230\u53ea\u6807 De40 \u7684\uff0c\u8981\u9000\u56de\u53bb\u8865\u3002<\/p>\n<h3>\u7b2c\u4e09\uff0c\u552e\u540e\u53e3\u5f84\u66ff\u8fd9\u5f20\u8868\u80cc\u4e66<\/h3>\n<p>\u6280\u672f\u901a\u77e5\u7684\u80cc\u666f\u8bf4\u660e\u5199\u5f97\u76f4\u767d\uff1a\u65e5\u7acb\u552e\u540e\u590d\u76d8 2022 \u5e74\u4ee5\u524d\u7684\u5929\u6c1f\u5730\u6c34\u9879\u76ee\uff0c<b>\u62a5\u6c34\u6d41\u6545\u969c\u7684\uff0c\u6839\u56e0\u57fa\u672c\u662f\u6c34\u8def\u7ba1\u9053\u9009\u578b\u8fc7\u5c0f\u3001\u6c34\u6d41\u91cf\u4e0d\u8db3\uff0c\u5c0f\u4e8e\u8bbe\u5907\u6700\u5c0f\u6c34\u6d41\u91cf<\/b>\uff1b\u800c\u65bd\u5de5\u56fe\u91cc\u7f3a\u4e3b\u7ba1\u6807\u6ce8\u3001\u7f3a\u7cfb\u7edf\u56fe\uff0c\u662f\u7ba1\u5f84\u88ab\u505a\u5c0f\u7684\u76f4\u63a5\u539f\u56e0\u3002\u7ba1\u5f84\u4e0d\u662f\u7ec6\u8282\uff0c\u662f\u552e\u540e\u6545\u969c\u7684\u5934\u53f7\u6e90\u5934\u3002<\/p>\n<h3>\u7b2c\u56db\uff0c\u88c5\u5b8c\u81ea\u5df1\u80fd\u67e5<\/h3>\n<p>\u4e09\u6b65\uff1a\u5148\u770b\u56fe\u7eb8\u4e3b\u7ba1\u6807\u6ce8\u662f\u4e0d\u662f\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u9f50\u5168\uff1b\u88c5\u5b8c\u8c03\u8bd5\u65f6\uff0c\u667a\u4eab\u7684\u7ebf\u63a7\u5668\u53ef\u4ee5\u76f4\u63a5\u70b9\u68c0\u6c34\u6d41\u91cf\uff08\u70b9\u68c0\u7801 b0\uff0c\u5b89\u88c5\u8bf4\u660e\u4e66\u91cc\u6709\u5199\uff09\uff1b\u4f7f\u7528\u4e2d\u5982\u679c\u62a5 <b>70 \u53f7\u6545\u969c\u4ee3\u7801<\/b>\uff0c\u5c31\u662f\u6c34\u6d41\u91cf\u8fc7\u4f4e\uff0c\u5148\u67e5\u4e3b\u7ba1\u7ba1\u5f84\u591f\u4e0d\u591f\u3001\u8fc7\u6ee4\u7f51\u5835\u6ca1\u5835\uff0c\u518d\u8c08\u522b\u7684\u3002<\/p>\n<h2 class=\"lmnt-h2\">\u53ef\u9009\u65b9\u5411\uff1a\u51e0\u6761\u8def\u5404\u9002\u5408\u8c01<\/h2>\n<table class=\"lmnt-table\">\n<thead>\n<tr>\n<th>\u5c42<\/th>\n<th>\u505a\u6cd5<\/th>\n<th>\u6cbb\u4ec0\u4e48<\/th>\n<th>\u4ec0\u4e48\u6761\u4ef6\u4e0b\u9009\u5b83<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u65b0\u88c5<\/td>\n<td>\u6309\u9009\u578b\u8868\u5b9a\u7ba1\u5f84\uff0c\u56fe\u7eb8\u6807\u5168\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d<\/td>\n<td>\u4ece\u6e90\u5934\u628a\u6d41\u91cf\u8d26\u7b97\u5bf9<\/td>\n<td>\u88c5\u4fee\u9636\u6bb5\u8fd8\u6ca1\u8fdb\u573a\uff0c\u4e00\u6b65\u5230\u4f4d<\/td>\n<\/tr>\n<tr>\n<td>\u52a0\u6cf5<\/td>\n<td>\u5185\u7f6e\u6cf5\u9876\u4e0d\u4f4f\u65f6\u6309\u6c34\u529b\u8ba1\u7b97\u52a0\u5916\u7f6e\u6cf5<\/td>\n<td>\u7ba1\u8def\u957f\u3001\u963b\u529b\u5927\u7684\u9879\u76ee<\/td>\n<td>\u6280\u672f\u901a\u77e5\u6ce8\u660e\u7684\u8def\u5b50\uff1a\u6309\u6c34\u6cf5\u7684\u6d41\u91cf-\u626c\u7a0b\u66f2\u7ebf\u9009\uff0c\u4e0d\u80fd\u6309\u6700\u9ad8\u626c\u7a0b\u3001\u6700\u5927\u6d41\u91cf\u9009<\/td>\n<\/tr>\n<tr>\n<td>\u5df2\u88c5<\/td>\n<td>\u5148\u70b9\u68c0\u5b9e\u9645\u6c34\u6d41\u91cf\u548c\u56de\u6c34\u6e29\u5ea6\uff0c\u518d\u5b9a\u8981\u4e0d\u8981\u52a8\u7ba1<\/td>\n<td>\u6000\u7591\u4e3b\u7ba1\u504f\u5c0f\u7684\u5728\u4f4f\u7cfb\u7edf<\/td>\n<td>\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u67e5\u6c34\u6d41\u91cf\uff1b\u56de\u6c34\u6301\u7eed\u504f\u9ad8\u3001\u4e3b\u673a\u9891\u7e41\u542f\u505c\u7684\uff0c\u627e\u552e\u540e\u6838\u7ba1\u5f84<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u58c1\u6302\u7089\u8fd9\u8fb9\u662f\u540c\u4e00\u7b14\u8d26\u7684\u53e6\u4e00\u534a\u3002<b>\u58c1\u6302\u7089\u5e26\u5730\u6696\uff0c\u4e3b\u7ba1\u4e00\u5f8b De32 \u8d77\u6b65<\/b>\u2014\u2014\u8fd9\u8ddf\u4e24\u8054\u4f9b\u7684 De40\u3001De50 \u662f\u4e24\u4e2a\u53e3\u5f84\uff0c\u522b\u62ff\u53bb\u4e92\u76f8\u6bd4\u5927\u5c0f\uff0c\u6bd4\u7684\u662f\u5404\u81ea\u7684\u6d41\u91cf\u8d26\u3002\u4f46\u300c\u7ba1\u5f84\u504f\u5c0f\u4f1a\u600e\u6837\u300d\u7684\u903b\u8f91\u4e24\u8fb9\u901a\u7528\uff1a\u7ba1\u7ec6\u4e86\u963b\u529b\u5927\uff0c\u6d41\u91cf\u4e0a\u4e0d\u53bb\uff0c\u56de\u6c34\u6e29\u5ea6\u504f\u9ad8\uff0c\u4e3b\u673a\uff08\u6216\u58c1\u6302\u7089\uff09\u9891\u7e41\u542f\u505c\uff0c\u80fd\u8017\u8ddf\u7740\u6da8\u3002\u6211\u4eec\u81ea\u5df1\u7684\u65b9\u6848\u4e66\u91cc\u7b97\u8fc7\u4e00\u7b14\u8d26\uff1a\u4e00\u6237 115.6\u33a1 \u6697\u57cb\u6696\u6c14\u7247\uff08\u4f55\u5148\u751f\u5bb6\uff09\uff0c\u70ed\u8d1f\u8377\u7ea6 15 \u5343\u74e6\uff0c\u4e3b\u7ba1 30 \u7c73\uff0c\u7528 De25 \u65f6\u6700\u5927\u6d41\u91cf\u7ea6 500L\/h\u3001\u6309 20\u2103 \u6e29\u5dee\u70ed\u4f20\u8f93\u80fd\u529b\u7ea6 11.6 \u5343\u74e6\uff0c\u5df2\u7ecf\u8d34\u7740\u4e34\u754c\uff1b\u6362 De32 \u6d41\u91cf\u7ea6 800L\/h\u3001\u7ea6 18.6 \u5343\u74e6\uff0c\u6d41\u91cf\u63d0\u5347 60%\uff0c30 \u7c73\u7ba1\u6750\u5dee\u4ef7\u7ea6 150 \u5143\u3002150 \u5757\u94b1\u4e70\u5230\u6d41\u91cf\u4f59\u91cf\uff0c\u8fd9\u7b14\u8d26\u600e\u4e48\u7b97\u90fd\u4e0d\u4e8f\u2014\u2014<b>\u7ba1\u5f84\u4e0d\u662f\u7701\u94b1\u7684\u5730\u65b9<\/b>\u3002<\/p>\n<h2 class=\"lmnt-h2\">\u5e38\u89c1\u95ee\u9898<\/h2>\n<h3>\u95ee\uff1a\u5929\u6c1f\u5730\u6c34\u7684\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7684\u7c97\uff1f<\/h3>\n<p>\u7b54\uff1a\u6839\u5b50\u5728\u6e29\u5dee\u3002\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff1b\u58c1\u6302\u7089\u5e26\u6696\u6c14\u7247\u6309 20\u2103 \u6e29\u5dee\u7b97\u8d26\u3002\u70ed\u91cf\uff1d\u6d41\u91cf\u00d71.163\u00d7\u6e29\u5dee\uff0c\u540c\u6837 10 \u5343\u74e6\u70ed\u91cf\uff0c5\u2103 \u6e29\u5dee\u8981 1.72 \u7acb\u65b9\u7c73\/\u5c0f\u65f6\u7684\u6d41\u91cf\uff0c20\u2103 \u6e29\u5dee\u53ea\u8981 0.43\u2014\u2014\u5dee\u56db\u500d\uff0c\u6d41\u91cf\u5927\u4e86\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002<\/p>\n<h3>\u95ee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4e3b\u7ba1\u4e00\u822c\u8981\u591a\u5927\uff1f<\/h3>\n<p>\u7b54\uff1a\u6309\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\uff08PPR \u7ba1\u3001S5 \u7cfb\u5217\u3001\u4f9b\u56de\u6c34 45\/40\u2103\uff09\uff1a\u5c0f\u6237\u578b\u673a\u578b De40 \u8d77\u6b65\uff0c\u4e3b\u6d41\u673a\u578b\u843d\u5728 De50\uff0c8\uff5e12HP \u7684\u4e09\u76f8\u673a\u578b\u7528 De63\u3002\u5177\u4f53\u4ee5\u56fe\u7eb8\u4e0a\u7684\u9009\u578b\u6807\u6ce8\u4e3a\u51c6\u3002<\/p>\n<h3>\u95ee\uff1a\u4e3b\u7ba1\u7528\u7ec6\u4e86\u4f1a\u51fa\u4ec0\u4e48\u95ee\u9898\uff1f<\/h3>\n<p>\u7b54\uff1a\u6d41\u91cf\u4e0d\u8db3\uff0c\u5c0f\u4e8e\u8bbe\u5907\u6700\u5c0f\u6c34\u6d41\u91cf\u5c31\u62a5\u6c34\u6d41\u6545\u969c\uff1b\u6c34\u6d41\u591f\u4e0d\u5230\u672b\u7aef\u65f6\u9760\u62ac\u9ad8\u4f9b\u6c34\u6e29\u5ea6\u8865\u507f\uff0c\u6c34\u6e29\u6bcf\u63d0\u9ad8 10\u2103 \u80fd\u8017\u7ea6\u591a 15%\uff0c\u9505\u7089\u6216\u4e3b\u673a\u8fd8\u4f1a\u9891\u7e41\u542f\u505c\u3002\u65e5\u7acb\u6210\u90fd\u5206\u516c\u53f8\u552e\u540e\u590d\u76d8 2022 \u5e74\u4ee5\u524d\u7684\u5929\u6c1f\u5730\u6c34\u9879\u76ee\uff0c\u62a5\u6c34\u6d41\u6545\u969c\u7684\u6839\u56e0\u57fa\u672c\u662f\u4e3b\u7ba1\u9009\u578b\u8fc7\u5c0f\u3002<\/p>\n<h3>\u95ee\uff1a\u56fe\u7eb8\u4e0a\u4e3b\u7ba1\u6807\u6ce8\u8981\u6ce8\u610f\u4ec0\u4e48\uff1f<\/h3>\n<p>\u7b54\uff1a\u5fc5\u987b\u6807\u7ba1\u5f84\u7cfb\u5217\u3001\u5927\u5c0f\u548c\u58c1\u539a\uff0c\u5199\u6210\u300cS5 \u7cfb\u5217\uff0cDe40\u00d73.7mm\u300d\u8fd9\u6837\uff1b\u53ea\u5199 De40 \u4e0d\u7b97\u6570\u2014\u2014\u540c\u4e3a De40\uff0cS5 \u5185\u5f84 32.6 \u6beb\u7c73\uff0cS3.2 \u53ea\u6709 29.0 \u6beb\u7c73\uff0c\u58c1\u539a\u5dee\u4e00\u6863\uff0c\u6d41\u91cf\u5dee\u4e00\u5927\u622a\u3002<\/p>\n<h3>\u95ee\uff1a\u88c5\u5b8c\u600e\u4e48\u77e5\u9053\u6c34\u6d41\u91cf\u591f\u4e0d\u591f\uff1f<\/h3>\n<p>\u7b54\uff1a\u4e09\u6b65\uff1a\u5148\u770b\u56fe\u7eb8\u4e3b\u7ba1\u6807\u6ce8\u6709\u6ca1\u6709\u5199\u5168\u7cfb\u5217\u3001\u7ba1\u5f84\u3001\u58c1\u539a\uff1b\u88c5\u5b8c\u7528\u667a\u4eab\u7ebf\u63a7\u5668\u70b9\u68c0\u6c34\u6d41\u91cf\uff08\u70b9\u68c0\u7801 b0\uff09\uff1b\u8fd0\u884c\u4e2d\u62a5 70 \u53f7\u6545\u969c\u4ee3\u7801\u5c31\u662f\u6c34\u6d41\u91cf\u8fc7\u4f4e\uff0c\u5148\u67e5\u4e3b\u7ba1\u7ba1\u5f84\u548c\u8fc7\u6ee4\u7f51\u518d\u8c08\u6362\u6cf5\u3002<\/p>\n<h2 class=\"lmnt-h2\">\u76f8\u5173\u9875\u9762<\/h2>\n<ul>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=16752\">\u65e5\u7acb\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b \u00b7 \u667a\u4eab\u3001\u5168\u6548\u3001\u522b\u5885\u4e09\u79cd\u4e3b\u673a\u600e\u4e48\u914d<\/a> \u2014\u2014 \u4e3b\u673a\u9009\u578b\u5728\u8fd9\u9875\uff0c\u7ba1\u5f84\u8ddf\u7740\u673a\u578b\u8d70<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=16061\">\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u8bbe\u8ba1\u65b9\u6848\uff5c\u5185\u673a\u3001\u5916\u673a\u3001\u6c34\u6a21\u5757\u600e\u4e48\u5b9a<\/a> \u2014\u2014 \u8bbe\u5907\u6446\u4f4d\u4e0e\u6c34\u6a21\u5757\u7684\u5b9a\u6cd5<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=12825\">\u6210\u90fd\u6c34\u673avs\u6c1f\u673a\uff5c\u5929\u6c34\u5730\u6c34\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u600e\u4e48\u9009<\/a> \u2014\u2014 \u8fd8\u6ca1\u5b9a\u6c34\u673a\u6c1f\u673a\u7684\uff0c\u5148\u770b\u8fd9\u9875<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=15178\">\u6210\u90fd\u5bb6\u5ead\u9009\u91c7\u6696\uff1a\u65b0\u623f\u5730\u6696\u4e0e\u8001\u623f\u660e\u88c5\u6696\u6c14\u7247\u5206\u522b\u9002\u914d\u4ec0\u4e48\u6237\u578b<\/a> \u2014\u2014 \u58c1\u6302\u7089\u5e26\u5730\u6696\u4e3b\u7ba1\u4e00\u5f8b De32 \u8d77\u6b65<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=20689\">\u96f6\u51b7\u6c34\u5230\u5e95\u8be5\u4e0d\u8be5\u505a\uff1f\u652f\u7ba1\u5faa\u73af\u548c\u4e3b\u7ba1\u5faa\u73af\u600e\u4e48\u9009<\/a> \u2014\u2014 \u70ed\u6c34\u4fa7\u7684\u652f\u7ba1\u3001\u4e3b\u7ba1\u5faa\u73af\u600e\u4e48\u5206\u5de5<\/li>\n<li><a href=\"https:\/\/longmai-nt.com\/?page_id=671\">\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c<\/a> \u2014\u2014 \u4e24\u8054\u4f9b\u8fd9\u4e00\u7c7b\u7684\u5165\u53e3\uff0c\u4ece\u8fd9\u8fdb\u53bb<\/li>\n<\/ul>\n<h2 class=\"lmnt-h2\">\u627e\u9f99\u8109\u6696\u901a<\/h2>\n<p>\u624b\u4e0a\u5df2\u7ecf\u62ff\u5230\u4e24\u8054\u4f9b\u65b9\u6848\u56fe\u7684\uff0c\u628a\u4e3b\u7ba1\u6807\u6ce8\u90a3\u4e00\u680f\u62cd\u7ed9\u95e8\u5e97\uff0c\u6211\u4eec\u5bf9\u7740\u65e5\u7acb\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u5e2e\u4f60\u6838\u4e00\u904d\u7ba1\u5f84\u548c\u6807\u6ce8\u5199\u6cd5\uff1b\u8fd8\u6ca1\u5b9a\u65b9\u6848\u7684\uff0c\u53ef\u4ee5\u5148\u804a\u6c34\u673a\u548c\u6c1f\u673a\u7684\u5dee\u522b\uff0c\u518d\u770b\u673a\u578b\u5bf9\u5e94\u7684\u7ba1\u5f84\u53e3\u5f84\u3002\u4e24\u5bb6\u5e97\u90fd\u5728\u5bcc\u68ee\u7f8e\uff0c\u4e24\u4e2a\u95e8\u5e97\u7684\u8d1f\u8d23\u4eba\u76f4\u63a5\u5bf9\u63a5\uff08\u5fae\u4fe1\u540c\u53f7\uff09\uff1a<\/p>\n<ul>\n<li><strong>\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/strong>\uff08\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A347B \/ A348\uff09\uff5c \u70ed\u7ebf <a href=\"tel:02886131795\">028-86131795<\/a> \uff5c \u4f59\u6653\u73b2 <a href=\"tel:13008113409\">130-0811-3409<\/a> \uff5c <a href=\"https:\/\/maps.amap.com\/search?id=B0FFKQ3088&amp;city=510107\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/li>\n<li><strong>\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/strong>\uff08\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135\uff09\uff5c \u70ed\u7ebf <a href=\"tel:02865272586\">028-65272586<\/a> \uff5c \u9ec4\u52c7 <a href=\"tel:15828489188\">158-2848-9188<\/a> \uff5c <a href=\"https:\/\/maps.amap.com\/search?id=B0G12NIKK5&amp;city=510108\">\u4e00\u952e\u5bfc\u822a\uff08\u9ad8\u5fb7\uff09<\/a><\/li>\n<\/ul>\n<p>\u8425\u4e1a\u65f6\u95f4\uff1a\u5468\u4e00\u81f3\u5468\u4e94 10:00\u201318:00\uff0c\u5468\u516d\u81f3\u5468\u65e5 10:00\u201319:00\u3002<\/p>\n<p style=\"color:#999;font-size:12px;\">\u9875\u9762\u7f16\u53f7 NT03-02-002<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5ba2\u6237\u539f\u8bdd \u300a\u5730\u6696\u4e3b\u7ba1\uff0c\u4e3a\u4ec0\u4e48\u4e3b\u673a\u8d8a\u5c0f\u53cd\u800c [&hellip;]<\/p>\n","protected":false},"author":19,"featured_media":0,"parent":671,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-20914","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u6d41\u91cf\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff5c\u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6839\u5b50\u5728\u6e29\u5dee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff0c\u540c\u6837\u70ed\u91cf\u6d41\u91cf\u8981\u5927\u56db\u500d\uff0c\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002\u8fd9\u4e00\u9875\u628a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff0c\u9644\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u3001\u673a\u578b\u5bf9\u7167\u3001\u56fe\u7eb8\u6807\u6ce8\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50\u7684\u8981\u6c42\uff0c\u8fd8\u6709\u88c5\u5b8c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u81ea\u67e5\u6c34\u6d41\u91cf\u7684\u4e09\u6b65\u529e\u6cd5\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=20914\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u6d41\u91cf\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff5c\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6839\u5b50\u5728\u6e29\u5dee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff0c\u540c\u6837\u70ed\u91cf\u6d41\u91cf\u8981\u5927\u56db\u500d\uff0c\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002\u8fd9\u4e00\u9875\u628a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff0c\u9644\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u3001\u673a\u578b\u5bf9\u7167\u3001\u56fe\u7eb8\u6807\u6ce8\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50\u7684\u8981\u6c42\uff0c\u8fd8\u6709\u88c5\u5b8c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u81ea\u67e5\u6c34\u6d41\u91cf\u7684\u4e09\u6b65\u529e\u6cd5\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=20914\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-20T08:22:30+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20914\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20914\",\"name\":\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u6d41\u91cf\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff5c\u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-11-20T08:22:29+00:00\",\"dateModified\":\"2026-11-20T08:22:30+00:00\",\"description\":\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6839\u5b50\u5728\u6e29\u5dee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\\\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff0c\u540c\u6837\u70ed\u91cf\u6d41\u91cf\u8981\u5927\u56db\u500d\uff0c\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002\u8fd9\u4e00\u9875\u628a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff0c\u9644\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u3001\u673a\u578b\u5bf9\u7167\u3001\u56fe\u7eb8\u6807\u6ce8\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50\u7684\u8981\u6c42\uff0c\u8fd8\u6709\u88c5\u5b8c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u81ea\u67e5\u6c34\u6d41\u91cf\u7684\u4e09\u6b65\u529e\u6cd5\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20914#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20914\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=20914#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=671\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u6d41\u91cf\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff5c\u9f99\u8109\u6696\u901a","description":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6839\u5b50\u5728\u6e29\u5dee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff0c\u540c\u6837\u70ed\u91cf\u6d41\u91cf\u8981\u5927\u56db\u500d\uff0c\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002\u8fd9\u4e00\u9875\u628a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff0c\u9644\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u3001\u673a\u578b\u5bf9\u7167\u3001\u56fe\u7eb8\u6807\u6ce8\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50\u7684\u8981\u6c42\uff0c\u8fd8\u6709\u88c5\u5b8c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u81ea\u67e5\u6c34\u6d41\u91cf\u7684\u4e09\u6b65\u529e\u6cd5\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=20914","og_locale":"zh_CN","og_type":"article","og_title":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u6d41\u91cf\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff5c\u9f99\u8109\u6696\u901a","og_description":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6839\u5b50\u5728\u6e29\u5dee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff0c\u540c\u6837\u70ed\u91cf\u6d41\u91cf\u8981\u5927\u56db\u500d\uff0c\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002\u8fd9\u4e00\u9875\u628a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff0c\u9644\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u3001\u673a\u578b\u5bf9\u7167\u3001\u56fe\u7eb8\u6807\u6ce8\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50\u7684\u8981\u6c42\uff0c\u8fd8\u6709\u88c5\u5b8c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u81ea\u67e5\u6c34\u6d41\u91cf\u7684\u4e09\u6b65\u529e\u6cd5\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=20914","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-11-20T08:22:30+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=20914","url":"https:\/\/longmai-nt.com\/?page_id=20914","name":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u6d41\u91cf\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff5c\u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-11-20T08:22:29+00:00","dateModified":"2026-11-20T08:22:30+00:00","description":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6839\u5b50\u5728\u6e29\u5dee\uff1a\u4e24\u8054\u4f9b\u5730\u6696\u4f9b\u56de\u6c34 45\/40\u2103\uff0c\u6e29\u5dee\u53ea\u6709 5\u2103\uff0c\u540c\u6837\u70ed\u91cf\u6d41\u91cf\u8981\u5927\u56db\u500d\uff0c\u7ba1\u5b50\u81ea\u7136\u8981\u7c97\u3002\u8fd9\u4e00\u9875\u628a\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05\uff0c\u9644\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u901a\u77e5\u7684\u9009\u578b\u8868\u3001\u673a\u578b\u5bf9\u7167\u3001\u56fe\u7eb8\u6807\u6ce8\u300c\u7cfb\u5217\uff0b\u7ba1\u5f84\uff0b\u58c1\u539a\u300d\u4e09\u6837\u9f50\u7684\u8981\u6c42\uff0c\u8fd8\u6709\u88c5\u5b8c\u7528\u7ebf\u63a7\u5668\u70b9\u68c0\u7801 b0 \u81ea\u67e5\u6c34\u6d41\u91cf\u7684\u4e09\u6b65\u529e\u6cd5\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=20914#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=20914"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=20914#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e24\u8054\u4f9b \u00b7 \u6280\u672f\u6f14\u8fdb\u4e0e\u5b9e\u6218\u624b\u518c","item":"https:\/\/longmai-nt.com\/?page_id=671"},{"@type":"ListItem","position":3,"name":"\u5929\u6c1f\u5730\u6c34\u4e3b\u7ba1\u4e3a\u4ec0\u4e48\u6bd4\u58c1\u6302\u7089\u7c97\uff1f\u6e29\u5dee\u3001\u6d41\u91cf\u3001\u7ba1\u5f84\u4e00\u7b14\u7b97\u6e05"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4f4f\u6696\u623f\uff0c\u7b9720\u5e74\u603b\u8d26","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=20914"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20914\/revisions"}],"predecessor-version":[{"id":20915,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/20914\/revisions\/20915"}],"up":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/671"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=20914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}