{"id":2166,"date":"2026-06-05T14:12:52","date_gmt":"2026-06-05T06:12:52","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2166"},"modified":"2026-06-05T14:12:55","modified_gmt":"2026-06-05T06:12:55","slug":"%e9%be%99%e8%80%81%e5%b8%88%e6%97%a5%e7%ab%8b%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2166","title":{"rendered":"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848"},"content":{"rendered":"\n\n<style>\n  :root {\n    --primary: #1a5ca0;\n    --primary-light: #e8f1fa;\n    --accent: #c0392b;\n    --accent-light: #fdecea;\n    --green: #0f6e56;\n    --green-light: #e1f5ee;\n    --orange: #e67e22;\n    --orange-light: #fef3e6;\n    --blue-2: #2471a3;\n    --blue-2-light: #eaf2f8;\n    --gray-50: #f8f9fa;\n    --gray-100: #f1f3f5;\n    --gray-200: #e9ecef;\n    --gray-400: #ced4da;\n    --gray-600: #868e96;\n    --gray-800: #343a40;\n    --gray-900: #212529;\n    --radius: 10px;\n  }\n  * { margin: 0; padding: 0; box-sizing: border-box; }\n  body {\n    font-family: -apple-system, \"PingFang SC\", \"Microsoft YaHei\", sans-serif;\n    background: var(--gray-100);\n    color: var(--gray-900);\n    line-height: 1.6;\n    padding: 20px;\n  }\n  .page {\n    max-width: 860px;\n    margin: 0 auto;\n    background: #fff;\n    border-radius: 16px;\n    box-shadow: 0 2px 12px rgba(0,0,0,.06);\n    overflow: hidden;\n  }\n  .header {\n    background: linear-gradient(135deg, #1a5ca0 0%, #0d3f6e 100%);\n    color: #fff;\n    padding: 32px 28px 24px;\n  }\n  .header-brand {\n    font-size: 13px;\n    opacity: .8;\n    letter-spacing: 2px;\n  }\n  .header-title {\n    font-size: 22px;\n    font-weight: 600;\n    margin: 8px 0 4px;\n  }\n  .header-sub {\n    font-size: 14px;\n    opacity: .85;\n  }\n  .header-meta {\n    display: flex;\n    gap: 24px;\n    margin-top: 16px;\n    font-size: 12px;\n    opacity: .75;\n    flex-wrap: wrap;\n  }\n  .body { padding: 24px 28px 28px; }\n  .section { margin-bottom: 24px; }\n  .section-title {\n    font-size: 15px;\n    font-weight: 600;\n    color: var(--primary);\n    border-left: 3px solid var(--primary);\n    padding-left: 10px;\n    margin-bottom: 12px;\n  }\n  .section-title.scheme-a { color: var(--primary); border-left-color: var(--primary); }\n  .section-title.scheme-b { color: var(--green); border-left-color: var(--green); }\n  .section-title.compare { color: var(--accent); border-left-color: var(--accent); }\n\n  \/* \u5efa\u7b51\u4fe1\u606f\u5361\u7247 *\/\n  .info-grid {\n    display: grid;\n    grid-template-columns: 1fr 1fr;\n    gap: 8px;\n    font-size: 13px;\n    background: var(--gray-50);\n    border-radius: var(--radius);\n    padding: 14px 18px;\n  }\n  .info-grid .item { display: flex; justify-content: space-between; padding: 3px 0; }\n  .info-grid .item .label { color: var(--gray-600); }\n  .info-grid .item .val { font-weight: 500; }\n\n  \/* \u4f7f\u7528\u573a\u666f *\/\n  .scene-box {\n    background: var(--primary-light);\n    border-radius: var(--radius);\n    padding: 14px 18px;\n    font-size: 13px;\n    line-height: 1.8;\n  }\n  .scene-box strong { color: var(--primary); }\n\n  \/* \u914d\u7f6e\u8868 *\/\n  .config-table {\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 13px;\n  }\n  .config-table th {\n    background: var(--primary-light);\n    color: var(--primary);\n    font-weight: 600;\n    padding: 8px 10px;\n    text-align: left;\n    border-bottom: 2px solid var(--primary);\n    white-space: nowrap;\n  }\n  .config-table.scheme-b-table th {\n    background: var(--green-light);\n    color: var(--green);\n    border-bottom-color: var(--green);\n  }\n  .config-table td {\n    padding: 8px 10px;\n    border-bottom: 1px solid var(--gray-200);\n  }\n  .config-table tr:last-child td { border-bottom: none; }\n  .config-table .num { text-align: right; font-variant-numeric: tabular-nums; }\n  .config-table .subtotal-row {\n    background: var(--gray-50);\n    font-weight: 600;\n  }\n  .config-table .total-row {\n    background: var(--primary-light);\n    font-weight: 700;\n    font-size: 14px;\n  }\n  .config-table.scheme-b-table .total-row {\n    background: var(--green-light);\n  }\n  .discount-tag {\n    display: inline-block;\n    background: var(--green);\n    color: #fff;\n    font-size: 11px;\n    padding: 1px 6px;\n    border-radius: 4px;\n    margin-left: 4px;\n  }\n  .no-discount {\n    color: var(--gray-600);\n    font-size: 11px;\n  }\n\n  \/* \u8d85\u914d\u7387 *\/\n  .super-rate {\n    display: flex;\n    gap: 16px;\n    font-size: 13px;\n    margin-top: 8px;\n  }\n  .super-rate .item {\n    flex: 1;\n    background: var(--gray-50);\n    border-radius: 6px;\n    padding: 10px 12px;\n    text-align: center;\n  }\n  .super-rate .value {\n    font-size: 20px;\n    font-weight: 700;\n    color: var(--green);\n  }\n  .super-rate .value.warn { color: var(--orange); }\n  .super-rate .label { font-size: 11px; color: var(--gray-600); margin-top: 2px; }\n\n  .super-note {\n    font-size: 12px;\n    color: var(--gray-600);\n    margin-top: 8px;\n    line-height: 1.7;\n  }\n\n  \/* \u4ef7\u683c\u6c47\u603b *\/\n  .price-block {\n    background: var(--gray-50);\n    border-radius: var(--radius);\n    padding: 16px 20px;\n    margin-bottom: 12px;\n  }\n  .price-row {\n    display: flex;\n    justify-content: space-between;\n    align-items: center;\n    padding: 5px 0;\n    font-size: 14px;\n  }\n  .price-row .label { color: var(--gray-600); }\n  .price-row .value { font-variant-numeric: tabular-nums; }\n  .price-row.divider {\n    border-top: 1px dashed var(--gray-400);\n    margin-top: 4px;\n    padding-top: 8px;\n  }\n  .price-row.subtotal {\n    font-weight: 600;\n    font-size: 15px;\n  }\n  .price-row.total {\n    font-size: 22px;\n    font-weight: 700;\n    color: var(--accent);\n    border-top: 2px solid var(--gray-400);\n    padding-top: 10px;\n    margin-top: 6px;\n  }\n\n  \/* \u8ba1\u7b97\u6d41\u7a0b *\/\n  .calc-flow {\n    background: var(--gray-50);\n    border-radius: var(--radius);\n    padding: 14px 18px;\n    font-size: 13px;\n    line-height: 2;\n  }\n  .calc-flow .step {\n    display: flex;\n    justify-content: space-between;\n    padding: 2px 0;\n  }\n  .calc-flow .step .val { font-variant-numeric: tabular-nums; font-weight: 500; }\n  .calc-flow .step.deduct .val { color: var(--accent); }\n  .calc-flow .step.add .val { color: var(--orange); }\n  .calc-flow .step.result {\n    border-top: 2px solid var(--gray-400);\n    margin-top: 4px;\n    padding-top: 8px;\n    font-weight: 700;\n    font-size: 15px;\n  }\n  .calc-flow .step.result .val { color: var(--accent); }\n\n  \/* \u65b9\u6848\u5bf9\u6bd4\u8868\u683c *\/\n  .compare-table {\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 13px;\n  }\n  .compare-table th {\n    background: var(--accent-light);\n    color: var(--accent);\n    font-weight: 600;\n    padding: 8px 10px;\n    text-align: center;\n    border-bottom: 2px solid var(--accent);\n  }\n  .compare-table th:first-child { text-align: left; }\n  .compare-table td {\n    padding: 8px 10px;\n    border-bottom: 1px solid var(--gray-200);\n    text-align: center;\n  }\n  .compare-table td:first-child { text-align: left; }\n  .compare-table tr:last-child td { border-bottom: none; }\n  .compare-table .highlight { background: var(--green-light); font-weight: 600; }\n\n  \/* \u5361\u7247 *\/\n  .activity-card {\n    background: var(--accent-light);\n    border: 1px solid #f5c6cb;\n    border-radius: var(--radius);\n    padding: 14px 16px;\n    margin-bottom: 12px;\n  }\n  .activity-card .title {\n    font-size: 14px;\n    font-weight: 600;\n    color: var(--accent);\n    margin-bottom: 6px;\n  }\n  .activity-card ul {\n    font-size: 13px;\n    padding-left: 18px;\n    color: var(--gray-800);\n  }\n  .activity-card li { margin-bottom: 3px; }\n\n  .member-card {\n    background: var(--green-light);\n    border: 1px solid #b7e4d3;\n    border-radius: var(--radius);\n    padding: 14px 16px;\n    margin-bottom: 12px;\n  }\n  .member-card .title {\n    font-size: 14px;\n    font-weight: 600;\n    color: var(--green);\n    margin-bottom: 6px;\n  }\n  .member-card ul {\n    font-size: 13px;\n    padding-left: 18px;\n    color: var(--gray-800);\n  }\n  .member-card li { margin-bottom: 3px; }\n\n  .warranty-card {\n    background: var(--orange-light);\n    border: 1px solid #f0d0a0;\n    border-radius: var(--radius);\n    padding: 14px 16px;\n    margin-bottom: 12px;\n  }\n  .warranty-card .title {\n    font-size: 14px;\n    font-weight: 600;\n    color: var(--orange);\n    margin-bottom: 6px;\n  }\n  .warranty-card .content {\n    font-size: 13px;\n    color: var(--gray-800);\n  }\n\n  .highlight-card {\n    background: var(--blue-2-light);\n    border: 1px solid #aed6f1;\n    border-radius: var(--radius);\n    padding: 14px 16px;\n    margin-bottom: 12px;\n  }\n  .highlight-card .title {\n    font-size: 14px;\n    font-weight: 600;\n    color: var(--blue-2);\n    margin-bottom: 6px;\n  }\n  .highlight-card ul {\n    font-size: 13px;\n    padding-left: 18px;\n    color: var(--gray-800);\n  }\n  .highlight-card li { margin-bottom: 3px; }\n\n  .note {\n    font-size: 12px;\n    color: var(--gray-600);\n    line-height: 1.7;\n    padding: 12px 16px;\n    background: var(--gray-50);\n    border-radius: var(--radius);\n  }\n  .note strong { color: var(--gray-800); }\n\n  .tag-optional {\n    display: inline-block;\n    font-size: 10px;\n    padding: 1px 6px;\n    border-radius: 3px;\n    background: var(--orange-light);\n    color: var(--orange);\n    margin-left: 4px;\n    vertical-align: middle;\n  }\n  .tag-recommend {\n    display: inline-block;\n    font-size: 10px;\n    padding: 1px 6px;\n    border-radius: 3px;\n    background: var(--green-light);\n    color: var(--green);\n    margin-left: 4px;\n    vertical-align: middle;\n  }\n\n  .product-link {\n    display: inline-flex;\n    align-items: center;\n    gap: 6px;\n    color: var(--primary);\n    text-decoration: none;\n    font-size: 13px;\n    font-weight: 500;\n    padding: 6px 14px;\n    border: 1px solid var(--primary);\n    border-radius: 6px;\n    transition: all .2s;\n  }\n  .product-link:hover {\n    background: var(--primary);\n    color: #fff;\n  }\n\n  .footer {\n    text-align: center;\n    padding: 20px 28px;\n    font-size: 12px;\n    color: var(--gray-600);\n    border-top: 1px solid var(--gray-200);\n  }\n  .footer .slogan {\n    font-size: 14px;\n    font-weight: 600;\n    color: var(--primary);\n    margin-bottom: 4px;\n  }\n\n  @media (max-width: 600px) {\n    body { padding: 10px; }\n    .header { padding: 20px 16px 16px; }\n    .header-title { font-size: 18px; }\n    .body { padding: 16px; }\n    .config-table, .compare-table { font-size: 12px; }\n    .config-table th, .config-table td, .compare-table th, .compare-table td { padding: 6px 6px; }\n    .super-rate { flex-direction: column; gap: 8px; }\n    .header-meta { flex-direction: column; gap: 4px; }\n    .info-grid { grid-template-columns: 1fr; }\n  }\n<\/style>\n\n<div class=\"page\">\n\n  <!-- \u5934\u90e8 -->\n  <div class=\"header\">\n    <div class=\"header-brand\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546<\/div>\n    <div class=\"header-title\">\u9f99\u8001\u5e08 \u00b7 \u4e2d\u592e\u7a7a\u8c03\u53cc\u65b9\u6848\u62a5\u4ef7\u4e66<\/div>\n    <div class=\"header-sub\">\u65e5\u7acbVAM mini II \/ \u5c0a\u777f\u5168\u6548II \u00b7 \u6c1f\u7cfb\u7edf\u4e2d\u592e\u7a7a\u8c03<\/div>\n    <div class=\"header-meta\">\n      <span>\u62a5\u4ef7\u65e5\u671f\uff1a2026\u5e746\u67085\u65e5<\/span>\n      <span>\u6709\u6548\u671f\uff1a7\u5929<\/span>\n      <span>\u7f16\u53f7\uff1aQ-20260605-LONG<\/span>\n      <span>618\u6d3b\u52a8\u671f\u5185<\/span>\n    <\/div>\n  <\/div>\n\n  <div class=\"body\">\n\n    <!-- \u5efa\u7b51\u6982\u51b5 -->\n    <div class=\"section\">\n      <div class=\"section-title\">\u5efa\u7b51\u6982\u51b5\u4e0e\u4f7f\u7528\u573a\u666f<\/div>\n      <div class=\"info-grid\">\n        <div class=\"item\"><span class=\"label\">\u5efa\u7b51\u9762\u79ef<\/span><span class=\"val\">198 m\u00b2<\/span><\/div>\n        <div class=\"item\"><span class=\"label\">\u671d\u5411<\/span><span class=\"val\">\u671d\u5357<\/span><\/div>\n        <div class=\"item\"><span class=\"label\">\u697c\u5c42<\/span><span class=\"val\">\u4e24\u5c42\uff08\u4e00\u697c+\u4e8c\u697c\uff09<\/span><\/div>\n        <div class=\"item\"><span class=\"label\">\u91c7\u6696\u65b9\u5f0f<\/span><span class=\"val\">\u5df2\u6709\u5730\u6696<\/span><\/div>\n        <div class=\"item\"><span class=\"label\">\u7a7a\u8c03\u7528\u9014<\/span><span class=\"val\">\u4ec5\u5236\u51b7<\/span><\/div>\n        <div class=\"item\"><span class=\"label\">\u5ba2\u6237<\/span><span class=\"val\">\u9f99\u8001\u5e08<\/span><\/div>\n      <\/div>\n      <div class=\"scene-box\" style=\"margin-top:10px;\">\n        <strong>\u4f7f\u7528\u573a\u666f\uff1a<\/strong>\u665a\u4e0a\u5367\u5ba4\u5168\u5f00\uff1b\u767d\u5929\u5ba2\u9910\u5385\u5168\u5f00 + \u6700\u591a\u518d\u5f002\u4e2a\u5367\u5ba4\u3002<br>\n        <strong>\u8bbe\u8ba1\u524d\u63d0\uff1a<\/strong>\u623f\u5c4b\u5df2\u6709\u5730\u6696\u7cfb\u7edf\uff0c\u4e2d\u592e\u7a7a\u8c03\u4ec5\u627f\u62c5\u590f\u5b63\u5236\u51b7\u529f\u80fd\uff0c\u65e0\u9700\u5236\u70ed\u3002\n      <\/div>\n    <\/div>\n\n    <!-- ==================== \u65b9\u6848\u4e00 ==================== -->\n    <div class=\"section\">\n      <div class=\"section-title scheme-a\">\u65b9\u6848\u4e00\uff1a\u5e02\u573a\u901a\u914d\u6807\u51c6 \u2014 VAM mini II 200 \u4e00\u62d6\u516d<\/div>\n\n      <div style=\"font-size:12px;color:var(--gray-600);margin-bottom:12px;padding:6px 10px;background:var(--primary-light);border-radius:4px;\">\n        \u914d\u7f6e\u903b\u8f91\uff1a\u6309\u5e02\u573a\u901a\u914d\u60ef\u4f8b\uff0c\u5927\u7a7a\u95f4\uff08\u5ba2\u9910\u538555\u33a1\uff09\u91c7\u7528\u53cc\u5185\u673a\uff0871+40\uff09\u4fdd\u969c\u5236\u51b7\u5747\u5300\u6027\uff0c\u5404\u5367\u5ba4\u6309\u9762\u79ef\u5145\u88d5\u914d\u7f6e\u3002\n      <\/div>\n\n      <!-- \u4ea7\u54c1\u94fe\u63a5 -->\n      <div style=\"margin-bottom:12px;\">\n        <a class=\"product-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\n          <svg width=\"16\" height=\"16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" viewBox=\"0 0 24 24\"><path d=\"M18 13v6a2 2 0 01-2 2H5a2 2 0 01-2-2V8a2 2 0 012-2h6M15 3h6v6M10 14L21 3\"\/><\/svg>\n          \u67e5\u770bVAM mini II\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\n        <\/a>\n      <\/div>\n\n      <!-- \u8bbe\u5907\u914d\u7f6e -->\n      <table class=\"config-table\">\n        <thead>\n          <tr>\n            <th>\u4f4d\u7f6e<\/th>\n            <th>\u9762\u79ef<\/th>\n            <th>\u578b\u53f7<\/th>\n            <th>\u89c4\u683c<\/th>\n            <th class=\"num\">\u9762\u4ef7(\u5143)<\/th>\n            <th class=\"num\">\u6298\u540e\u4ef7(\u5143)<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>\u5ba4\u5916\u673a<\/td>\n            <td>\u2014<\/td>\n            <td>RAS-200FSVN8Q<\/td>\n            <td>200\u578b 8\u5339<\/td>\n            <td class=\"num\">29,600<\/td>\n            <td class=\"num\">19,240 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385 \u2460<\/td>\n            <td>55\u33a1<\/td>\n            <td>RPIZ-71FSVNAQD\/P<\/td>\n            <td>71\u578b 7.1kW<\/td>\n            <td class=\"num\">4,963<\/td>\n            <td class=\"num\">3,226 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385 \u2461<\/td>\n            <td>55\u33a1<\/td>\n            <td>RPIZ-40FSVNAQD\/P<\/td>\n            <td>40\u578b 4.0kW<\/td>\n            <td class=\"num\">4,513<\/td>\n            <td class=\"num\">2,933 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e00\u697c\u8001\u4eba\u623f<\/td>\n            <td>9.59\u33a1<\/td>\n            <td>RPIZ-22FSVNAQD\/P<\/td>\n            <td>22\u578b 2.2kW<\/td>\n            <td class=\"num\">4,113<\/td>\n            <td class=\"num\">2,673 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e8c\u697c\u4e3b\u5367<\/td>\n            <td>37\u33a1<\/td>\n            <td>RPIZ-63FSVNAQD\/P<\/td>\n            <td>63\u578b 6.3kW<\/td>\n            <td class=\"num\">4,963<\/td>\n            <td class=\"num\">3,226 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e8c\u697c\u6b21\u53671<\/td>\n            <td>15.7\u33a1<\/td>\n            <td>RPIZ-32FSVNAQD\/P<\/td>\n            <td>32\u578b 3.2kW<\/td>\n            <td class=\"num\">4,513<\/td>\n            <td class=\"num\">2,933 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e8c\u697c\u6b21\u53672<\/td>\n            <td>9\u33a1<\/td>\n            <td>RPIZ-22FSVNAQD\/P<\/td>\n            <td>22\u578b 2.2kW<\/td>\n            <td class=\"num\">4,113<\/td>\n            <td class=\"num\">2,673 <span class=\"discount-tag\">6.5\u6298<\/span><\/td>\n          <\/tr>\n          <tr class=\"subtotal-row\">\n            <td colspan=\"4\">\u8bbe\u5907\u5c0f\u8ba1\uff086\u5185\u673a + 1\u5916\u673a\uff09<\/td>\n            <td class=\"num\">56,778<\/td>\n            <td class=\"num\">36,906<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <!-- \u8d85\u914d\u7387 -->\n      <div style=\"margin-top:12px;\">\n        <div class=\"super-rate\">\n          <div class=\"item\">\n            <div class=\"value warn\">125%<\/div>\n            <div class=\"label\">\u8d85\u914d\u7387 250\/200<\/div>\n          <\/div>\n          <div class=\"item\">\n            <div class=\"value\" style=\"color:var(--green);\">\u5408\u89c4 \u2713<\/div>\n            <div class=\"label\">\u5141\u8bb8 50%~130%<\/div>\n          <\/div>\n          <div class=\"item\">\n            <div class=\"value warn\">\u504f\u9ad8<\/div>\n            <div class=\"label\">\u7406\u60f3 90%~110%<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"super-note\">\n          \u5185\u673a\u5408\u8ba1250\u578b(25.0kW) \/ \u5916\u673a200\u578b(20.0kW) = \u8d85\u914d\u7387125%\u3002\u5728\u5141\u8bb8\u8303\u56f4\u5185\uff0c\u7565\u8d85\u7406\u60f3\u533a\u95f4\u3002\u8003\u8651\u767d\u5929\u6700\u591a\u540c\u65f6\u5f00\u5ba2\u9910\u5385+2\u5367\u5ba4\uff0c\u5b9e\u9645\u540c\u65f6\u5f00\u673a\u7ea6166\u578b(71+40+22+32)\uff0c\u5b9e\u9645\u8d1f\u8377\u7387\u7ea683%\uff0c\u5916\u673a\u4ecd\u6709\u5145\u8db3\u4f59\u91cf\u3002\n        <\/div>\n      <\/div>\n\n      <!-- \u5b89\u88c5\u8d39 -->\n      <div style=\"margin-top:14px;\">\n        <table class=\"config-table\">\n          <thead>\n            <tr><th>\u9879\u76ee<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7<\/th><th class=\"num\">\u5c0f\u8ba1(\u5143)<\/th><\/tr>\n          <\/thead>\n          <tbody>\n            <tr>\n              <td>\u5916\u673a\u5b89\u88c5<\/td><td>1\u53f0<\/td><td>600\u5143\/\u53f0<\/td><td class=\"num\">600<\/td>\n            <\/tr>\n            <tr>\n              <td>\u5185\u673a\u5b89\u88c5\uff08DC\u6807\u51c6\u578b \/ \u591a\u5c42\uff09<\/td><td>6\u53f0<\/td><td>1,750\u5143\/\u53f0 <span class=\"no-discount\">\u4e0d\u6253\u6298<\/span><\/td><td class=\"num\">10,500<\/td>\n            <\/tr>\n            <tr class=\"subtotal-row\">\n              <td colspan=\"3\">\u5b89\u88c5\u8d39\u5c0f\u8ba1<\/td>\n              <td class=\"num\">11,100<\/td>\n            <\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <!-- \u4ef7\u683c\u6c47\u603b -->\n      <div style=\"margin-top:12px;\">\n        <div class=\"price-block\">\n          <div class=\"price-row\">\n            <span class=\"label\">\u8bbe\u5907\u9762\u4ef7\u5408\u8ba1<\/span>\n            <span class=\"value\">\u00a5 56,778<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u6298\u6263\uff08VAM mini II 6.5\u6298\uff09<\/span>\n            <span class=\"value\" style=\"color:var(--accent);\">-\u00a5 19,872<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u8bbe\u5907\u6298\u540e\u4ef7<\/span>\n            <span class=\"value\">\u00a5 36,906<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u5b89\u88c5\u8d39\uff08\u5916\u673a600 + \u5185\u673a1,750\u00d76\uff09<\/span>\n            <span class=\"value\">\u00a5 11,100<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u8f85\u6750\u8d39<\/span>\n            <span class=\"value\">\u6309\u5b9e\u9645\u5de5\u5730\u5b9a\u4f4d\u6838\u7b97<\/span>\n          <\/div>\n          <div class=\"price-row subtotal divider\">\n            <span>\u8bbe\u5907 + \u5b89\u88c5 \u5408\u8ba1<\/span>\n            <span>\u00a5 48,006<\/span>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <!-- 618\u540e\u4ef7\u683c -->\n      <div class=\"calc-flow\">\n        <div class=\"step\">\n          <span>\u8bbe\u5907 + \u5b89\u88c5 \u5c0f\u8ba1<\/span>\n          <span class=\"val\">\u00a5 48,006<\/span>\n        <\/div>\n        <div class=\"step deduct\">\n          <span>618\u5b9a\u91d1\u81a8\u80c0\uff08mini\u53ca\u4ee5\u4e0a \u2192 19.9\u5143\u62b51,000\u5143\uff09<\/span>\n          <span class=\"val\">-\u00a5 1,000<\/span>\n        <\/div>\n        <div class=\"step\">\n          <span>\u5ef6\u4fdd\u8d39\u7528\uff08mini\u4e8c\u7b7e\u7ea6\u514d\u8d39\u900110\u5e74\u8d28\u4fdd\uff09<\/span>\n          <span class=\"val\">\u00a5 0<\/span>\n        <\/div>\n        <div class=\"step result\">\n          <span>618\u6d3b\u52a8\u540e\u5b9e\u4ed8<\/span>\n          <span class=\"val\">\u00a5 47,006<\/span>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- ==================== \u65b9\u6848\u4e8c ==================== -->\n    <div class=\"section\">\n      <div class=\"section-title scheme-b\">\u65b9\u6848\u4e8c\uff1a\u56fd\u6807GB\u5236\u51b7\u6807\u51c6 \u2014 \u5c0a\u777f\u5168\u6548II 160 \u4e00\u62d6\u4e94<\/div>\n\n      <div style=\"font-size:12px;color:var(--gray-600);margin-bottom:12px;padding:6px 10px;background:var(--green-light);border-radius:4px;\">\n        \u914d\u7f6e\u903b\u8f91\uff1a\u4e25\u683c\u53c2\u7167\u56fd\u6807GB\u5236\u51b7\u8d1f\u8377\u6807\u51c6\uff0c\u5ba2\u9910\u5385\u5355\u5185\u673a(71\u578b)\u6ee1\u8db3\u5236\u51b7\u9700\u6c42\uff0c\u5168\u5c4b\u914d\u7f6e\u66f4\u7cbe\u7b80\uff0c\u5185\u673a\u5347\u7ea7\u4e3a\u4e8c\u7ba1\u5236\u51c0\u5316\u578b\uff0c\u5916\u673a\u5347\u7ea7\u4e3a\u5c0a\u777f\u5168\u6548\u7cfb\u5217\u3002\n      <\/div>\n\n      <!-- \u4ea7\u54c1\u94fe\u63a5 -->\n      <div style=\"margin-bottom:12px;\">\n        <a class=\"product-link\" href=\"https:\/\/longmai-nt.com\/?page_id=1077\" target=\"_blank\">\n          <svg width=\"16\" height=\"16\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" viewBox=\"0 0 24 24\"><path d=\"M18 13v6a2 2 0 01-2 2H5a2 2 0 01-2-2V8a2 2 0 012-2h6M15 3h6v6M10 14L21 3\"\/><\/svg>\n          \u67e5\u770b\u5c0a\u777f\u5168\u6548II\u7cfb\u5217\u5b8c\u6574\u4ea7\u54c1\u4ecb\u7ecd\n        <\/a>\n      <\/div>\n\n      <!-- \u8bbe\u5907\u914d\u7f6e -->\n      <table class=\"config-table scheme-b-table\">\n        <thead>\n          <tr>\n            <th>\u4f4d\u7f6e<\/th>\n            <th>\u9762\u79ef<\/th>\n            <th>\u578b\u53f7<\/th>\n            <th>\u89c4\u683c<\/th>\n            <th class=\"num\">\u9762\u4ef7(\u5143)<\/th>\n            <th class=\"num\">\u6298\u540e\u4ef7(\u5143)<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>\u5ba4\u5916\u673a<\/td>\n            <td>\u2014<\/td>\n            <td>RAS-160FSXPN5Q<\/td>\n            <td>160\u578b 6\u5339<\/td>\n            <td class=\"num\">20,600<\/td>\n            <td class=\"num\">16,480 <span class=\"discount-tag\">8\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385<\/td>\n            <td>55\u33a1<\/td>\n            <td>RPIZ-71FSVNZ1QD\/PC<\/td>\n            <td>71\u578b 7.1kW \u51c0\u5316<\/td>\n            <td class=\"num\">5,238<\/td>\n            <td class=\"num\">4,190 <span class=\"discount-tag\">8\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e00\u697c\u8001\u4eba\u623f<\/td>\n            <td>9.59\u33a1<\/td>\n            <td>RPIZ-22FSVNZ1QD\/PC<\/td>\n            <td>22\u578b 2.2kW \u51c0\u5316<\/td>\n            <td class=\"num\">4,425<\/td>\n            <td class=\"num\">3,540 <span class=\"discount-tag\">8\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e8c\u697c\u4e3b\u5367<\/td>\n            <td>37\u33a1<\/td>\n            <td>RPIZ-56FSVNZ1QD\/PC<\/td>\n            <td>56\u578b 5.6kW \u51c0\u5316<\/td>\n            <td class=\"num\">5,088<\/td>\n            <td class=\"num\">4,070 <span class=\"discount-tag\">8\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e8c\u697c\u6b21\u53671<\/td>\n            <td>15.7\u33a1<\/td>\n            <td>RPIZ-25FSVNZ1QD\/PC<\/td>\n            <td>25\u578b 2.5kW \u51c0\u5316<\/td>\n            <td class=\"num\">4,513<\/td>\n            <td class=\"num\">3,610 <span class=\"discount-tag\">8\u6298<\/span><\/td>\n          <\/tr>\n          <tr>\n            <td>\u4e8c\u697c\u6b21\u53672<\/td>\n            <td>9\u33a1<\/td>\n            <td>RPIZ-22FSVNZ1QD\/PC<\/td>\n            <td>22\u578b 2.2kW \u51c0\u5316<\/td>\n            <td class=\"num\">4,425<\/td>\n            <td class=\"num\">3,540 <span class=\"discount-tag\">8\u6298<\/span><\/td>\n          <\/tr>\n          <tr class=\"subtotal-row\">\n            <td colspan=\"4\">\u8bbe\u5907\u5c0f\u8ba1\uff085\u5185\u673a + 1\u5916\u673a\uff09<\/td>\n            <td class=\"num\">44,289<\/td>\n            <td class=\"num\">35,431<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <!-- \u8d85\u914d\u7387 -->\n      <div style=\"margin-top:12px;\">\n        <div class=\"super-rate\">\n          <div class=\"item\">\n            <div class=\"value warn\">122.5%<\/div>\n            <div class=\"label\">\u8d85\u914d\u7387 196\/160<\/div>\n          <\/div>\n          <div class=\"item\">\n            <div class=\"value\" style=\"color:var(--green);\">\u5408\u89c4 \u2713<\/div>\n            <div class=\"label\">\u5141\u8bb8 50%~130%<\/div>\n          <\/div>\n          <div class=\"item\">\n            <div class=\"value warn\">\u504f\u9ad8<\/div>\n            <div class=\"label\">\u7406\u60f3 90%~110%<\/div>\n          <\/div>\n        <\/div>\n        <div class=\"super-note\">\n          \u5185\u673a\u5408\u8ba1196\u578b(19.6kW) \/ \u5916\u673a160\u578b(16.0kW) = \u8d85\u914d\u7387122.5%\u3002\u767d\u5929\u5ba2\u9910\u5385+2\u5367\u5ba4\u5b9e\u9645\u540c\u65f6\u5f00\u673a\u7ea6118\u578b(71+22+25)\uff0c\u5b9e\u9645\u8d1f\u8377\u7387\u7ea674%\uff0c\u5916\u673a\u4f59\u91cf\u5145\u8db3\u3002\n        <\/div>\n      <\/div>\n\n      <!-- \u5b89\u88c5\u8d39 -->\n      <div style=\"margin-top:14px;\">\n        <table class=\"config-table scheme-b-table\">\n          <thead>\n            <tr><th>\u9879\u76ee<\/th><th>\u6570\u91cf<\/th><th>\u5355\u4ef7<\/th><th class=\"num\">\u5c0f\u8ba1(\u5143)<\/th><\/tr>\n          <\/thead>\n          <tbody>\n            <tr>\n              <td>\u5916\u673a\u5b89\u88c5<\/td><td>1\u53f0<\/td><td>600\u5143\/\u53f0<\/td><td class=\"num\">600<\/td>\n            <\/tr>\n            <tr>\n              <td>\u5185\u673a\u5b89\u88c5\uff08\u4e24\u7ba1\u5236\u51c0\u5316\u578b \/ \u591a\u5c42\uff09<\/td><td>5\u53f0<\/td><td>1,750\u5143\/\u53f0 <span class=\"no-discount\">\u4e0d\u6253\u6298<\/span><\/td><td class=\"num\">8,750<\/td>\n            <\/tr>\n            <tr class=\"subtotal-row\">\n              <td colspan=\"3\">\u5b89\u88c5\u8d39\u5c0f\u8ba1<\/td>\n              <td class=\"num\">9,350<\/td>\n            <\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <!-- \u4ef7\u683c\u6c47\u603b -->\n      <div style=\"margin-top:12px;\">\n        <div class=\"price-block\">\n          <div class=\"price-row\">\n            <span class=\"label\">\u8bbe\u5907\u9762\u4ef7\u5408\u8ba1<\/span>\n            <span class=\"value\">\u00a5 44,289<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u6298\u6263\uff08\u5c0a\u777f\u5168\u6548 8\u6298\uff09<\/span>\n            <span class=\"value\" style=\"color:var(--accent);\">-\u00a5 8,858<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u8bbe\u5907\u6298\u540e\u4ef7<\/span>\n            <span class=\"value\">\u00a5 35,431<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u5b89\u88c5\u8d39\uff08\u5916\u673a600 + \u5185\u673a1,750\u00d75\uff09<\/span>\n            <span class=\"value\">\u00a5 9,350<\/span>\n          <\/div>\n          <div class=\"price-row\">\n            <span class=\"label\">\u8f85\u6750\u8d39<\/span>\n            <span class=\"value\">\u6309\u5b9e\u9645\u5de5\u5730\u5b9a\u4f4d\u6838\u7b97<\/span>\n          <\/div>\n          <div class=\"price-row subtotal divider\">\n            <span>\u8bbe\u5907 + \u5b89\u88c5 \u5408\u8ba1<\/span>\n            <span>\u00a5 44,781<\/span>\n          <\/div>\n        <\/div>\n      <\/div>\n\n      <!-- 618\u540e\u4ef7\u683c -->\n      <div class=\"calc-flow\">\n        <div class=\"step\">\n          <span>\u8bbe\u5907 + \u5b89\u88c5 \u5c0f\u8ba1<\/span>\n          <span class=\"val\">\u00a5 44,781<\/span>\n        <\/div>\n        <div class=\"step deduct\">\n          <span>618\u5b9a\u91d1\u81a8\u80c0\uff08\u5c0a\u777f\u5168\u6548 \u2192 19.9\u5143\u62b51,000\u5143\uff09<\/span>\n          <span class=\"val\">-\u00a5 1,000<\/span>\n        <\/div>\n        <div class=\"step\">\n          <span>\u5ef6\u4fdd\u8d39\u7528\uff08\u5c0a\u777f\u5168\u6548\u7b7e\u7ea6\u514d\u8d39\u900110\u5e74\u8d28\u4fdd\uff09<\/span>\n          <span class=\"val\">\u00a5 0<\/span>\n        <\/div>\n        <div class=\"step result\">\n          <span>618\u6d3b\u52a8\u540e\u5b9e\u4ed8<\/span>\n          <span class=\"val\">\u00a5 43,781<\/span>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- ==================== \u65b9\u6848\u5bf9\u6bd4 ==================== -->\n    <div class=\"section\">\n      <div class=\"section-title compare\">\u65b9\u6848\u5bf9\u6bd4\u603b\u89c8<\/div>\n      <table class=\"compare-table\">\n        <thead>\n          <tr>\n            <th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n            <th>\u65b9\u6848\u4e00\uff1aVAM mini II 200<\/th>\n            <th>\u65b9\u6848\u4e8c\uff1a\u5c0a\u777f\u5168\u6548II 160<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>\u4ea7\u54c1\u7cfb\u5217<\/td>\n            <td>VAM mini II<\/td>\n            <td>\u5c0a\u777f\u5168\u6548II<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5916\u673a\u578b\u53f7<\/td>\n            <td>RAS-200FSVN8Q\uff088\u5339\uff09<\/td>\n            <td>RAS-160FSXPN5Q\uff086\u5339\uff09<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5185\u673a\u7c7b\u578b<\/td>\n            <td>DC\u6807\u51c6\u578b\uff085\u53f0\u6807\u51c6 + 2\u53f0\u6807\u51c6\uff09<\/td>\n            <td>\u4e8c\u7ba1\u5236\u51c0\u5316\u578b\uff085\u53f0\u5168\u51c0\u5316\uff09<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5185\u673a\u6570\u91cf<\/td>\n            <td>6\u53f0\uff08\u5ba2\u9910\u5385\u53cc\u5185\u673a\uff09<\/td>\n            <td>5\u53f0\uff08\u5ba2\u9910\u5385\u5355\u5185\u673a\uff09<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5185\u673a\u603b\u5bb9\u91cf<\/td>\n            <td>250\u578b\uff0825.0kW\uff09<\/td>\n            <td>196\u578b\uff0819.6kW\uff09<\/td>\n          <\/tr>\n          <tr>\n            <td>\u8d85\u914d\u7387<\/td>\n            <td>125%<\/td>\n            <td>122.5%<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ba2\u9910\u5385\u65b9\u6848<\/td>\n            <td>71+40\u53cc\u5185\u673a\uff0c\u5236\u51b7\u66f4\u5747\u5300<\/td>\n            <td>71\u5355\u5185\u673a\uff0c\u56fd\u6807\u8fbe\u6807<\/td>\n          <\/tr>\n          <tr>\n            <td>\u51c0\u5316\u529f\u80fd<\/td>\n            <td>\u65e0\uff08\u6807\u51c6\u5185\u673a\uff09<\/td>\n            <td>\u5168\u7cfb\u5185\u7f6e\u51c0\u5316\u6a21\u5757<\/td>\n          <\/tr>\n          <tr>\n            <td>\u8bbe\u8ba1\u7406\u5ff5<\/td>\n            <td>\u5e02\u573a\u901a\u914d\u60ef\u4f8b\uff0c\u504f\u5145\u88d5<\/td>\n            <td>\u56fd\u6807\u5236\u51b7\u6807\u51c6\uff0c\u504f\u7cbe\u51c6<\/td>\n          <\/tr>\n          <tr>\n            <td>\u8bbe\u5907\u9762\u4ef7<\/td>\n            <td>\u00a5 56,778<\/td>\n            <td>\u00a5 44,289<\/td>\n          <\/tr>\n          <tr>\n            <td>\u6298\u540e\u8bbe\u5907\u4ef7<\/td>\n            <td>\u00a5 36,906\uff086.5\u6298\uff09<\/td>\n            <td>\u00a5 35,431\uff088\u6298\uff09<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5b89\u88c5\u8d39<\/td>\n            <td>\u00a5 11,100\uff08\u5185\u673a1,750\u00d76\uff09<\/td>\n            <td>\u00a5 9,350\uff08\u5185\u673a1,750\u00d75\uff09<\/td>\n          <\/tr>\n          <tr class=\"highlight\">\n            <td>618\u6d3b\u52a8\u540e\u5b9e\u4ed8<\/td>\n            <td>\u00a5 47,006<\/td>\n            <td>\u00a5 43,781<\/td>\n          <\/tr>\n          <tr>\n            <td>\u5ef6\u4fdd<\/td>\n            <td>\u514d\u8d3910\u5e74<\/td>\n            <td>\u514d\u8d3910\u5e74<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <!-- \u65b9\u6848\u5dee\u5f02\u89e3\u8bfb -->\n    <div class=\"section\">\n      <div class=\"section-title\">\u65b9\u6848\u5dee\u5f02\u89e3\u8bfb<\/div>\n\n      <div class=\"highlight-card\">\n        <div class=\"title\">\u65b9\u6848\u4e00\u4f18\u52bf\uff1a\u5236\u51b7\u8986\u76d6\u66f4\u5145\u88d5<\/div>\n        <ul>\n          <li>\u5ba2\u9910\u538555\u33a1\u914d\u7f6e71+40\u53cc\u5185\u673a\uff0c\u5236\u51b7\u6c14\u6d41\u8986\u76d6\u66f4\u5747\u5300\uff0c\u5927\u7a7a\u95f4\u65e0\u6b7b\u89d2<\/li>\n          <li>\u5916\u673a200\u578b(8\u5339)\u529f\u7387\u50a8\u5907\u66f4\u8db3\uff0c\u6781\u7aef\u9ad8\u6e29\u5929\u6c14\u4ece\u5bb9\u5e94\u5bf9<\/li>\n          <li>\u9002\u5408\u5bf9\u5236\u51b7\u901f\u5ea6\u3001\u5747\u5300\u6027\u8981\u6c42\u8f83\u9ad8\u7684\u4f7f\u7528\u4e60\u60ef<\/li>\n        <\/ul>\n      <\/div>\n\n      <div class=\"highlight-card\">\n        <div class=\"title\">\u65b9\u6848\u4e8c\u4f18\u52bf\uff1a\u6027\u4ef7\u6bd4 + \u51c0\u5316\u5347\u7ea7<\/div>\n        <ul>\n          <li>\u5168\u7cfb\u5185\u673a\u5347\u7ea7\u4e3a\u4e8c\u7ba1\u5236\u51c0\u5316\u578b\uff0c\u5185\u7f6ePE\u7eaf\u51c0\u751f\u6001\u6a21\u5757\uff0c\u5236\u51b7\u540c\u65f6\u51c0\u5316\u7a7a\u6c14<\/li>\n          <li>\u5c0a\u777f\u5168\u6548II\u4e3a\u65e5\u7acb\u65d7\u8230\u7cfb\u5217\uff0c\u538b\u7f29\u673a\u3001\u63a7\u5236\u7cfb\u7edf\u3001\u9759\u97f3\u7b49\u7ea7\u5747\u4f18\u4e8emini\u7cfb\u5217<\/li>\n          <li>618\u6d3b\u52a8\u540e\u5b9e\u4ed8\u4f4e\u00a53,225\uff0c\u6027\u4ef7\u6bd4\u7a81\u51fa<\/li>\n          <li>\u56fd\u680771\u578b\u5355\u5185\u673a\u5373\u53ef\u6ee1\u8db355\u33a1\u5ba2\u9910\u5385\u5236\u51b7\u9700\u6c42\uff08\u6309GB\u6807\u51c6130W\/\u33a1\u8ba1\u7b97\uff0c\u9700\u6c42\u7ea67.15kW\uff0c71\u578b7.1kW\u521a\u597d\u8986\u76d6\uff09<\/li>\n        <\/ul>\n      <\/div>\n\n      <div class=\"note\" style=\"margin-top:8px;\">\n        <strong>\u6838\u5fc3\u53d6\u820d\uff1a<\/strong>\u65b9\u6848\u4e00\u591a\u82b1\u7ea6\u00a53,225\uff0c\u6362\u6765\u5ba2\u9910\u5385\u53cc\u5185\u673a\u66f4\u5747\u5300\u7684\u5236\u51b7\u4f53\u9a8c + \u66f4\u5927\u7684\u5916\u673a\u529f\u7387\u50a8\u5907\uff1b\u65b9\u6848\u4e8c\u540c\u6837\u6ee1\u8db3\u5236\u51b7\u9700\u6c42\uff0c\u4e14\u83b7\u5f97\u5168\u5c4b\u51c0\u5316\u529f\u80fd + \u66f4\u9ad8\u7aef\u7684\u4e3b\u673a\u5e73\u53f0\u3002\u4e24\u8005\u5747\u4e3a\u5408\u89c4\u914d\u7f6e\uff0c\u8d85\u914d\u7387\u5747\u5728\u5141\u8bb8\u8303\u56f4\u5185\u3002\n      <\/div>\n    <\/div>\n\n    <!-- ==================== 618\u6d3b\u52a8 ==================== -->\n    <div class=\"section\">\n      <div class=\"section-title\">618\u54c1\u8d28\u8282\u80fd\u5b63 \u6d3b\u52a8\u6743\u76ca<\/div>\n      <div class=\"activity-card\">\n        <div class=\"title\">19.9\u5143\u5b9a\u91d1\u81a8\u80c0<\/div>\n        <ul>\n          <li>mini\u53ca\u4ee5\u4e0a\u7cfb\u5217\uff08\u542bVAM mini II \/ \u5c0a\u777f\u5168\u6548\uff09\uff1a19.9\u5143\u5b9a\u91d1 \u2192 \u62b5\u6263 <strong>1,000\u5143<\/strong> \u8d27\u6b3e<\/li>\n          <li>\u6d3b\u52a8\u65f6\u95f4\uff1a2026\u5e745\u670829\u65e5 \u2014 6\u670830\u65e5\uff08\u517133\u5929\uff09<\/li>\n          <li>\u5f53\u524d\u62a5\u4ef7\u5df2\u81ea\u52a8\u8ba1\u5165618\u62b5\u6263<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"warranty-card\">\n        <div class=\"title\">10\u5e74\u6574\u673a\u8d28\u4fdd\uff08\u514d\u8d39\uff09<\/div>\n        <div class=\"content\">\n          \u4e24\u4e2a\u65b9\u6848\u5747\u4e3amini\u4e8c\/\u5c0a\u777f\u5168\u6548\u7cfb\u5217\uff0c\u7b7e\u7ea6\u5373<strong>\u514d\u8d39\u8d60\u900110\u5e74\u6574\u673a\u8d28\u4fdd<\/strong>\uff0c\u65e0\u9700\u989d\u5916\u8d2d\u4e70\u5ef6\u4fdd\u5361\u3002\n        <\/div>\n      <\/div>\n      <div style=\"font-size:12px;color:var(--gray-600);margin-top:8px;\">\n        <strong>\u8bf4\u660e\uff1a<\/strong>\u672c\u6848\u672a\u914d\u7f6e\u65b0\u98ce\u6216\u6c34\u6a21\u5757\uff0c\u4e0d\u6d89\u53ca\u8054\u5355\u6743\u76ca\u3002\u5982\u9700\u52a0\u914d\u65b0\u98ce\u7cfb\u7edf\u6216\u5347\u7ea7\u4e3a\u4e24\u8054\u4f9b\uff08\u7a7a\u8c03+\u5730\u6696\u4e8c\u5408\u4e00\uff09\uff0c\u53ef\u53e6\u884c\u6838\u7b97\u8054\u5355\u62b5\u6263\uff08\u65b0\u98ce\u6216\u6c34\u6a21\u5757\u62b52,000\u5143\uff0c\u4e24\u8005\u90fd\u9009\u62b53,600\u5143\uff09\u3002\n      <\/div>\n    <\/div>\n\n    <!-- ==================== \u4f1a\u5458\u5236 ==================== -->\n    <div class=\"section\">\n      <div class=\"section-title\">\u4f1a\u5458\u589e\u503c\u6743\u76ca<\/div>\n      <div class=\"member-card\">\n        <div class=\"title\">\u9f99\u8109\u4f1a\u5458\u5236\uff08199\u5143\/\u5e74\uff09<\/div>\n        <ul>\n          <li>\u7b7e\u7ea6\u65f6\u6696\u901a\u91d1\u989d1,000\u5143\u76f4\u63a5\u62b5\u6263\u9996\u5e74\u4f1a\u8d39 \u2192 \u5b9e\u4ed8 <strong>0\u5143<\/strong> \u5165\u4f1a<\/li>\n          <li>\u6696\u901a\u91d1\u989d\u8fd8\u53ef\u8986\u76d6\u524d5\u5e74\u4f1a\u8d39\uff08199\u00d75=995\u5143\uff09\u2192 \u524d5\u5e74\u4f1a\u5458\u8d39 <strong>0\u5143<\/strong><\/li>\n          <li>\u5ef6\u4fdd\u81f310\u5e74 + \u670d\u52a15~8\u6298 + \u514d\u8d39\u4e0a\u95e8\u4e0d\u9650\u6b21\u6570 + \u51ac\u590f\u9ad8\u5cf0\u671f\u4f18\u5148\u6d3e\u5355<\/li>\n          <li>\u81ea\u52a8\u52a0\u516510\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff0c\u4eab\u5e74\u5ea6\u80fd\u8017\u5206\u6790\u62a5\u544a<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"warranty-card\">\n        <div class=\"title\">10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff08618\u7b7e\u7ea6\u81ea\u52a8\u52a0\u5165\uff09<\/div>\n        <div class=\"content\">\n          \u56db\u4e2a\u8def\u6807\u8282\u70b9\uff08\u7b2c1\/3\/5\/10\u5e74\uff09\u5b9a\u671f\u4ea4\u4ed8\u80fd\u8017\u62a5\u544a\u4e0e\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\uff0c\u516d\u7ef4\u5ea6\uff08\u8fd0\u884c\u8d39\/\u7ef4\u62a4\u8d39\/\u4f7f\u7528\u5bff\u547d\/\u7cfb\u7edf\u7a33\u5b9a\u6027\/\u8212\u9002\u5ea6\/\u521d\u6295\u8d44\uff09\u5168\u5468\u671f\u8ddf\u8e2a\u300220\u5e74\u8d85\u957f\u670d\u52a1\u4fdd\u969c\uff0c10\u5e74\u8ddf\u8e2a\u671f\u6ee1\u540e\u7ee7\u7eed\u7ef4\u4fdd\u81f320\u5e74\u3002\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- ==================== \u5907\u6ce8 ==================== -->\n    <div class=\"section\">\n      <div class=\"section-title\">\u5907\u6ce8<\/div>\n      <div class=\"note\">\n        <strong>1.<\/strong> \u8f85\u6750\u8d39\u6309\u5b9e\u9645\u5de5\u5730\u5b9a\u4f4d\u6838\u7b97\uff0c\u542b\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u6392\u6c34\u3001\u7ebf\u7f06\u7b49\uff0c\u8be6\u89c1\u8f85\u6750\u914d\u7f6e\u6e05\u5355\uff08\u6307\u4ee406\uff09\u3002<br>\n        <strong>2.<\/strong> \u62a5\u4ef7\u6709\u6548\u671f7\u5929\uff0c\u903e\u671f\u9700\u91cd\u65b0\u6838\u7b97\u3002618\u6d3b\u52a8\u6743\u76ca\u4ec5\u96502026\u5e745\u670829\u65e5\u20146\u670830\u65e5\u671f\u95f4\u7b7e\u7ea6\u6709\u6548\u3002<br>\n        <strong>3.<\/strong> \u6298\u6263\u8ba1\u7b97\u987a\u5e8f\uff1a\u9762\u4ef7 \u2192 \u6298\u6263\uff08\u65b9\u6848\u4e006.5\u6298 \/ \u65b9\u6848\u4e8c8\u6298\uff09\u2192 618\u6d3b\u52a8\u62b5\u6263 \u2192 \u6700\u7ec8\u4ef7\uff0c\u4e0d\u53ef\u9006\u5e8f\u3002<br>\n        <strong>4.<\/strong> \u65b9\u6848\u4e8c\u5185\u673a\u9762\u4ef7\u4f9d\u636e\u6307\u4ee402\u5c0a\u777f\u667a\u4eab\u5171\u7528\u5185\u673a\uff08\u4e24\u7ba1\u5236\u51c0\u5316\uff09\u4ef7\u683c\u8868\uff0c22\u578b\u53d64,425\u5143\u300125\u578b\u53d64,513\u5143\u300156\u578b\u53d65,088\u5143\u300171\u578b\u53d65,238\u5143\u3002<br>\n        <strong>5.<\/strong> \u672c\u62a5\u4ef7\u4ec5\u542b\u7a7a\u8c03\u8bbe\u5907\u53ca\u5b89\u88c5\uff0c\u4e0d\u542b\u5730\u6696\u7cfb\u7edf\uff08\u5ba2\u6237\u5df2\u6709\u5730\u6696\uff09\u3002<br>\n        <strong>6.<\/strong> \u56fd\u6807\u5236\u51b7\u8d1f\u8377\u53c2\u8003GB 50736-2012\uff0c\u4f4f\u5b85\u590f\u5b63\u5236\u51b7\u6309130~160W\/\u33a1\u4f30\u7b97\uff0c\u672c\u62a5\u4ef7\u53d6\u9002\u4e2d\u503c\u3002<br>\n        <strong>7.<\/strong> \u4e24\u4e2a\u65b9\u6848\u5916\u673a\u5747\u53ef\u5b89\u88c5\u4e8e\u5ba4\u5916\u6307\u5b9a\u4f4d\u7f6e\uff0c\u5b89\u88c5\u524d\u9700\u73b0\u573a\u52d8\u5bdf\u786e\u8ba4\u5916\u673a\u4f4d\u5c3a\u5bf8\u53ca\u7535\u6e90\u6761\u4ef6\u3002<br>\n        <strong>8.<\/strong> \u672c\u62a5\u4ef7\u6309\u591a\u5c42\u4f4f\u5b85\u6807\u51c6\uff0c\u7edf\u4e00\u5185\u673a\u5b89\u88c5\u8d391,750\u5143\/\u53f0\uff0c\u4e0d\u6253\u6298\u3002\u5916\u673a\u5b89\u88c5\u8d39600\u5143\/\u53f0\u3002\n      <\/div>\n    <\/div>\n\n  <\/div>\n\n  <!-- \u9875\u811a -->\n  <div class=\"footer\">\n    <div class=\"slogan\">\u9f99\u8109\u6696\u901a \u00b7 \u8ba9\u5bb6\u66f4\u8212\u9002<\/div>\n    <div>\u6210\u90fd\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 | \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546<\/div>\n    <div style=\"margin-top:4px;\">\u672c\u62a5\u4ef7\u7531\u9f99\u8109\u6696\u901aGEO\u6570\u5b57\u5316\u4f53\u7cfb\u751f\u6210\uff0c\u6570\u636e\u6e90\uff1a\u6307\u4ee402\u4ef7\u683c\u5e93V5.0 \/ \u6307\u4ee40\u5de5\u4f5c\u57fa\u7ebfV6.1<\/div>\n    <div>\u4ec5\u4f9b\u53c2\u8003\uff0c\u4ee5\u7b7e\u7ea6\u5408\u540c\u4e3a\u51c6<\/div>\n  <\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u6388\u6743\u7ecf\u9500\u5546 \u9f99 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2166","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u9f99\u8001\u5e08Min\u4e00\u62d6\u516d\u65b9\u6848\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2166\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u9f99\u8001\u5e08Min\u4e00\u62d6\u516d\u65b9\u6848\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2166\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-05T06:12:55+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2166\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2166\",\"name\":\"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-05T06:12:52+00:00\",\"dateModified\":\"2026-06-05T06:12:55+00:00\",\"description\":\"\u9f99\u8001\u5e08Min\u4e00\u62d6\u516d\u65b9\u6848\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2166#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2166\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2166#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848 - \u9f99\u8109\u6696\u901a","description":"\u9f99\u8001\u5e08Min\u4e00\u62d6\u516d\u65b9\u6848","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2166","og_locale":"zh_CN","og_type":"article","og_title":"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u9f99\u8001\u5e08Min\u4e00\u62d6\u516d\u65b9\u6848","og_url":"https:\/\/longmai-nt.com\/?page_id=2166","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-05T06:12:55+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2166","url":"https:\/\/longmai-nt.com\/?page_id=2166","name":"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-05T06:12:52+00:00","dateModified":"2026-06-05T06:12:55+00:00","description":"\u9f99\u8001\u5e08Min\u4e00\u62d6\u516d\u65b9\u6848","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2166#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2166"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2166#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5c0f\u7ea2\u4e66\u9f99\u8001\u5e08\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2166"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2166\/revisions"}],"predecessor-version":[{"id":2167,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2166\/revisions\/2167"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}