{"id":2168,"date":"2026-06-06T21:59:27","date_gmt":"2026-06-06T13:59:27","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2168"},"modified":"2026-06-19T15:40:13","modified_gmt":"2026-06-19T07:40:13","slug":"%e6%81%92%e5%a4%a7%e5%b1%b1%e6%b0%b4%e5%9f%8e-%e5%88%98%e5%a5%b3%e5%a3%ab%e6%97%a5%e7%ab%8b%e5%b0%8a%e7%9d%bf%e5%85%a8%e6%95%88%e4%b8%89%e8%81%94%e4%be%9b%e7%b3%bb%e7%bb%9f%e6%a1%a3%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2168","title":{"rendered":"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">\u6863\u6848\u7f16\u53f7\uff1aB-B hdsscls001<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u8be6\u60c5<\/th><\/tr><\/thead><tbody><tr><td>\u5ba2\u6237\u59d3\u540d<\/td><td>\u5218\u5973\u58eb                                                         <\/td><\/tr><tr><td>\u9879\u76ee\u5730\u5740<\/td><td>\u6052\u5927\u5c71\u6c34\u57ce346-101<\/td><\/tr><tr><td>\u9500\u552e\u987e\u95ee<\/td><td>\u9ec4\u52c7 15828489188<\/td><\/tr><tr><td>\u6863\u6848\u7ba1\u7406<\/td><td>\u9ec4\u52c7<\/td><\/tr><tr><td>\u7f16\u5236\u65e5\u671f<\/td><td>2026\u5e746\u670813\u65e5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u6863\u6848\u76ee\u5f55<\/h2>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u7b2c\u4e00\u9636\u6bb5: \u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-1\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n\n<div class=\"lm-wrapper\">\n<style>\n\/* ============================================================\n   \u9f99\u8109\u6696\u901a \u00b7 \u65b9\u6848\u4e66WordPress\u7247\u6bb5 v2.0\n   \u57fa\u4e8e\uff1alongmai-nt.com\/?page_id=2541\uff08\u9633\u5973\u58eb\u65b9\u6848\u4e66\uff09\n   \u89c4\u8303\uff1aWordPress Self-Contained Fragment \u00b7 lm- \u524d\u7f00\u9694\u79bb\n   ============================================================ *\/\n\n\/* --- \u57fa\u7840\u5bb9\u5668 --- *\/\n.lm-wrapper {\n  max-width: 100%;\n  overflow-x: hidden;\n  box-sizing: border-box;\n  display: block;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", \"PingFang SC\", \"Hiragino Sans GB\", \"Microsoft YaHei\", \"Helvetica Neue\", Arial, sans-serif;\n  color: #333333;\n  line-height: 1.7;\n  background: #f5f7fa;\n}\n\n.lm-wrapper *, .lm-wrapper *::before, .lm-wrapper *::after {\n  box-sizing: border-box;\n}\n\n\/* ============================================================\n   \u5c01\u9762\u533a \u00b7 Hero Section\n   ============================================================ *\/\n.lm-wrapper .lm-hero {\n  background: linear-gradient(150deg, #0d2b5e 0%, #1a4a8a 45%, #0d6efd 100%) !important;\n  color: #ffffff !important;\n  padding: 60px 40px 50px;\n  text-align: center;\n  position: relative;\n  overflow: hidden;\n}\n\n.lm-wrapper .lm-hero::before {\n  content: \"\";\n  position: absolute;\n  top: -60px;\n  right: -60px;\n  width: 300px;\n  height: 300px;\n  background: rgba(255,255,255,0.04);\n  border-radius: 50%;\n}\n\n.lm-wrapper .lm-hero::after {\n  content: \"\";\n  position: absolute;\n  bottom: -80px;\n  left: -40px;\n  width: 250px;\n  height: 250px;\n  background: rgba(255,255,255,0.03);\n  border-radius: 50%;\n}\n\n.lm-wrapper .lm-hero-brand {\n  font-size: 12px;\n  letter-spacing: 4px;\n  opacity: 0.7;\n  text-transform: uppercase;\n  margin-bottom: 10px;\n  color: #ffffff !important;\n}\n\n.lm-wrapper .lm-hero h1 {\n  font-size: 34px;\n  font-weight: 800;\n  margin: 10px 0 6px;\n  letter-spacing: 2px;\n  line-height: 1.3;\n  color: #ffffff !important;\n  text-shadow: 0 2px 16px rgba(0,0,0,0.6);\n}\n\n.lm-wrapper .lm-hero .lm-hero-sub {\n  font-size: 16px;\n  opacity: 0.85;\n  margin-bottom: 28px;\n  letter-spacing: 1px;\n  color: #ffffff !important;\n  text-shadow: 0 1px 8px rgba(0,0,0,0.4);\n}\n\n.lm-wrapper .lm-hero-info {\n  display: flex;\n  justify-content: center;\n  gap: 40px;\n  flex-wrap: wrap;\n  margin-bottom: 30px;\n  font-size: 14px;\n  opacity: 0.9;\n  color: #ffffff !important;\n}\n\n.lm-wrapper .lm-hero-info div {\n  text-align: left;\n}\n\n.lm-wrapper .lm-hero-info span {\n  display: block;\n  font-size: 11px;\n  opacity: 0.6;\n  margin-bottom: 2px;\n  color: #ffffff !important;\n}\n\n\/* \u951a\u70b9\u5bfc\u822a\u6309\u94ae\u7ec4 *\/\n.lm-wrapper .lm-hero-nav {\n  display: flex;\n  justify-content: center;\n  gap: 12px;\n  flex-wrap: wrap;\n}\n\n.lm-wrapper .lm-hero-nav a {\n  display: inline-block;\n  padding: 8px 20px;\n  border: 1px solid rgba(255,255,255,0.4);\n  border-radius: 20px;\n  color: #ffffff;\n  font-size: 13px;\n  text-decoration: none;\n  transition: all 0.2s;\n  background: rgba(255,255,255,0.1);\n}\n\n.lm-wrapper .lm-hero-nav a:hover {\n  background: rgba(255,255,255,0.25);\n  border-color: rgba(255,255,255,0.7);\n}\n\n\/* ============================================================\n   \u901a\u7528\u6bb5\u843d\u6837\u5f0f\n   ============================================================ *\/\n.lm-wrapper p {\n  margin: 0 0 12px 0;\n  font-size: 14px;\n  line-height: 1.7;\n}\n\n.lm-wrapper h2 {\n  font-size: 22px;\n  font-weight: 700;\n  color: #1a1a1a;\n  margin: 40px 0 20px 0;\n  padding-bottom: 10px;\n  border-bottom: 3px solid #2563eb;\n}\n\n.lm-wrapper h3 {\n  font-size: 17px;\n  font-weight: 600;\n  color: #1a1a1a;\n  margin: 28px 0 14px 0;\n}\n\n.lm-wrapper a {\n  color: #2563eb;\n  text-decoration: none;\n}\n\n.lm-wrapper a:hover {\n  text-decoration: underline;\n}\n\n\/* ============================================================\n   \u8868\u683c\u7cfb\u7edf\n   ============================================================ *\/\n.lm-wrapper .lm-table-wrap {\n  width: 100%;\n  overflow-x: auto;\n  -webkit-overflow-scrolling: touch;\n  margin: 16px 0;\n  border-radius: 8px;\n  border: 1px solid #e5e7eb;\n}\n\n.lm-wrapper table {\n  width: 100%;\n  min-width: 640px;\n  border-collapse: collapse;\n  font-size: 13px;\n  background: #ffffff;\n}\n\n.lm-wrapper th, .lm-wrapper td {\n  padding: 10px 14px;\n  border: 1px solid #e5e7eb;\n  text-align: left;\n  vertical-align: top;\n}\n\n.lm-wrapper th {\n  background: #f0f4ff;\n  font-weight: 600;\n  color: #1e40af;\n  white-space: nowrap;\n}\n\n.lm-wrapper tr:nth-child(even) td {\n  background: #f9fafb;\n}\n\n.lm-wrapper tr:hover td {\n  background: #eff6ff;\n}\n\n\/* \u4ef7\u683c\u9ad8\u4eae *\/\n.lm-wrapper .lm-price {\n  color: #dc2626;\n  font-weight: 700;\n  font-size: 15px;\n}\n\n\/* ============================================================\n   \u65b9\u6848\u5361\u7247\uff08\u53cc\u5217\uff09\n   ============================================================ *\/\n.lm-wrapper .lm-plan-cards {\n  display: flex;\n  gap: 24px;\n  margin: 24px 0;\n  flex-wrap: wrap;\n}\n\n.lm-wrapper .lm-plan-card {\n  flex: 1;\n  min-width: 280px;\n  background: #ffffff;\n  border-radius: 12px;\n  overflow: hidden;\n  box-shadow: 0 4px 16px rgba(0,0,0,0.08);\n  border: 1px solid #e5e7eb;\n}\n\n.lm-wrapper .lm-plan-card-header {\n  padding: 18px 20px;\n  color: #ffffff;\n  font-weight: 700;\n  font-size: 16px;\n}\n\n.lm-wrapper .lm-plan-card-a .lm-plan-card-header {\n  background: #2563eb;\n}\n\n.lm-wrapper .lm-plan-card-b .lm-plan-card-header {\n  background: #d97706;\n}\n\n.lm-wrapper .lm-plan-card-body {\n  padding: 20px;\n}\n\n.lm-wrapper .lm-plan-card-price {\n  font-size: 28px;\n  font-weight: 800;\n  margin: 10px 0;\n}\n\n.lm-wrapper .lm-plan-card-a .lm-plan-card-price {\n  color: #2563eb;\n}\n\n.lm-wrapper .lm-plan-card-b .lm-plan-card-price {\n  color: #d97706;\n}\n\n\/* ============================================================\n   \u8b66\u793a\u6846\n   ============================================================ *\/\n.lm-wrapper .lm-alert {\n  background: #fef3c7;\n  border: 1px solid #f59e0b;\n  border-radius: 8px;\n  padding: 14px 18px;\n  margin: 16px 0;\n  font-size: 13px;\n  line-height: 1.6;\n  color: #92400e;\n}\n\n.lm-wrapper .lm-alert strong {\n  color: #78350f;\n}\n\n\/* ============================================================\n   \u4ef7\u503c\u5361\u7247\u7f51\u683c\n   ============================================================ *\/\n.lm-wrapper .lm-value-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 16px;\n  margin: 20px 0;\n}\n\n.lm-wrapper .lm-value-card {\n  background: #ffffff;\n  border-radius: 10px;\n  padding: 20px;\n  text-align: center;\n  box-shadow: 0 2px 8px rgba(0,0,0,0.06);\n  border: 1px solid #e5e7eb;\n}\n\n.lm-wrapper .lm-value-card .lm-value-icon {\n  font-size: 32px;\n  margin-bottom: 10px;\n}\n\n.lm-wrapper .lm-value-card h4 {\n  font-size: 15px;\n  font-weight: 700;\n  margin: 0 0 8px 0;\n  color: #1e40af;\n}\n\n.lm-wrapper .lm-value-card p {\n  font-size: 12px;\n  color: #6b7280;\n  margin: 0;\n}\n\n\/* ============================================================\n   \u670d\u52a1\u627f\u8bfa\u516d\u5bab\u683c\n   ============================================================ *\/\n.lm-wrapper .lm-service-grid {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 16px;\n  margin: 20px 0;\n}\n\n.lm-wrapper .lm-service-card {\n  background: #ffffff;\n  border-radius: 10px;\n  padding: 20px 16px;\n  text-align: center;\n  box-shadow: 0 2px 8px rgba(0,0,0,0.06);\n  border: 1px solid #e5e7eb;\n}\n\n.lm-wrapper .lm-service-card .lm-service-icon {\n  font-size: 28px;\n  margin-bottom: 8px;\n}\n\n.lm-wrapper .lm-service-card h4 {\n  font-size: 14px;\n  font-weight: 700;\n  margin: 0 0 6px 0;\n  color: #1e40af;\n}\n\n.lm-wrapper .lm-service-card p {\n  font-size: 12px;\n  color: #6b7280;\n  margin: 0;\n}\n\n\/* ============================================================\n   \u4f1a\u5458\u6743\u76ca\u5361\u7247\uff08\u6d45\u5e95\u9ed1\u5b57\u7248\uff09\n   ============================================================ *\/\n.lm-wrapper .lm-member-box {\n  background: linear-gradient(135deg, #eff6ff 0%, #dbeafe 100%);\n  color: #1a1a1a;\n  border-radius: 12px;\n  padding: 28px;\n  margin: 20px 0;\n  border: 1px solid #bfdbfe;\n}\n\n.lm-wrapper .lm-member-box h3 {\n  color: #1e40af;\n  margin-top: 0;\n}\n\n.lm-wrapper .lm-member-box table th {\n  background: #2563eb;\n  color: #ffffff;\n}\n\n.lm-wrapper .lm-member-box table td {\n  color: #1a1a1a;\n  border-color: #e5e7eb;\n}\n\n\/* ============================================================\n   \u4ef7\u683c\u5927\u5361\u7247\n   ============================================================ *\/\n.lm-wrapper .lm-price-hero {\n  text-align: center;\n  padding: 40px 20px;\n  border-radius: 16px;\n  margin: 24px 0;\n}\n\n.lm-wrapper .lm-price-hero-a {\n  background: linear-gradient(135deg, #eff6ff 0%, #dbeafe 100%);\n  border: 2px solid #2563eb;\n}\n\n.lm-wrapper .lm-price-hero-b {\n  background: linear-gradient(135deg, #fffbeb 0%, #fef3c7 100%);\n  border: 2px solid #d97706;\n}\n\n.lm-wrapper .lm-price-hero .lm-price-label {\n  font-size: 16px;\n  color: #6b7280;\n  margin-bottom: 8px;\n}\n\n.lm-wrapper .lm-price-hero .lm-price-amount {\n  font-size: 48px;\n  font-weight: 800;\n  line-height: 1.1;\n}\n\n.lm-wrapper .lm-price-hero-a .lm-price-amount {\n  color: #2563eb;\n}\n\n.lm-wrapper .lm-price-hero-b .lm-price-amount {\n  color: #d97706;\n}\n\n.lm-wrapper .lm-price-hero .lm-price-note {\n  font-size: 13px;\n  color: #6b7280;\n  margin-top: 8px;\n}\n\n\/* ============================================================\n   \u661f\u7ea7\u8bc4\u5206\n   ============================================================ *\/\n.lm-wrapper .lm-stars {\n  color: #f59e0b;\n  font-size: 14px;\n}\n\n.lm-wrapper .lm-stars-dim {\n  color: #d1d5db;\n}\n\n\/* ============================================================\n   \u6253\u5370\u6837\u5f0f\n   ============================================================ *\/\n@media print {\n  .lm-wrapper {\n    background: #ffffff;\n  }\n  .lm-wrapper .lm-hero {\n    background: #1a4a8a !important;\n    -webkit-print-color-adjust: exact;\n    print-color-adjust: exact;\n  }\n  .lm-wrapper .lm-service-card,\n  .lm-wrapper .lm-value-card,\n  .lm-wrapper .lm-plan-card {\n    break-inside: avoid;\n    box-shadow: none;\n    border: 1px solid #d1d5db;\n  }\n}\n\n\/* ============================================================\n   \u54cd\u5e94\u5f0f\u65ad\u70b9\n   ============================================================ *\/\n@media (max-width: 739px) {\n  .lm-wrapper .lm-hero {\n    padding: 40px 20px 35px;\n  }\n  .lm-wrapper .lm-hero h1 {\n    font-size: 26px;\n  }\n  .lm-wrapper .lm-hero-nav {\n    gap: 8px;\n  }\n  .lm-wrapper .lm-hero-nav a {\n    padding: 6px 14px;\n    font-size: 12px;\n  }\n  .lm-wrapper .lm-plan-cards {\n    flex-direction: column;\n  }\n  .lm-wrapper .lm-service-grid {\n    grid-template-columns: repeat(2, 1fr);\n  }\n  .lm-wrapper .lm-value-grid {\n    grid-template-columns: repeat(2, 1fr);\n  }\n  .lm-wrapper h2 {\n    font-size: 19px;\n  }\n  .lm-wrapper table {\n    font-size: 12px;\n  }\n  .lm-wrapper th, .lm-wrapper td {\n    padding: 8px 10px;\n  }\n}\n<\/style>\n\n<!-- ============================== -->\n<!-- \u7b2c1\u9879\uff1a\u5c01\u9762\u9875 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"cover\">\n<div class=\"lm-hero\">\n  <div class=\"lm-hero-brand\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u65b9\u6848\u4e66<\/div>\n  <h1>\u5218\u5973\u58eb \u00b7 \u6052\u5927\u5c71\u6c34\u57ce<\/h1>\n  <div class=\"lm-hero-sub\">\u4e09\u5c42\u8054\u6392\u522b\u5885 \u00b7 \u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34+\u8336\u5ba4\u98ce\u7ba1\u673a \u00b7 \u4e00\u7ad9\u5f0f\u89e3\u51b3\u65b9\u6848<\/div>\n  <div class=\"lm-hero-info\">\n    <div><span>\u5ba2\u6237\u540d\u79f0<\/span>\u5218\u5973\u58eb<\/div>\n    <div><span>\u9879\u76ee\u5730\u5740<\/span>\u5927\u9091\u53bf\u00b7\u6052\u5927\u5c71\u6c34\u57ce\uff08\u4e09\u5c42\u8054\u6392\u522b\u5885\uff09<\/div>\n    <div><span>\u65b9\u6848\u987e\u95ee<\/span>\u9ec4\u52c7<\/div>\n    <div><span>\u65b9\u6848\u65e5\u671f<\/span>2026\u5e743\u670818\u65e5<\/div>\n  <\/div>\n  <div class=\"lm-hero-nav\">\n    <a href=\"#needs\">\u9700\u6c42\u5206\u6790<\/a>\n    <a href=\"#design\">\u8bbe\u8ba1\u7406\u5ff5<\/a>\n    <a href=\"#config\">\u8bbe\u5907\u914d\u7f6e<\/a>\n    <a href=\"#price\">\u900f\u660e\u62a5\u4ef7<\/a>\n    <a href=\"#compare\">\u65b9\u6848\u5bf9\u6bd4<\/a>\n    <a href=\"#service\">\u670d\u52a1\u627f\u8bfa<\/a>\n  <\/div>\n<\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c2\u9879\uff1a\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"needs\" style=\"padding: 40px 40px 20px;\">\n  <h2>\u4e00\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n  <p>\u6211\u4eec\u8ba4\u771f\u8046\u542c\u4e86\u60a8\u7684\u6bcf\u4e00\u53e5\u8bdd\uff0c\u5e76\u5c06\u5176\u8f6c\u5316\u4e3a\u53ef\u843d\u5730\u7684\u7cfb\u7edf\u8bbe\u8ba1\u65b9\u6848\u3002<\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th style=\"width:50%\">\u60a8\u8bf4\u7684 \/ \u60a8\u7684\u60c5\u51b5<\/th>\n          <th style=\"width:50%\">\u6211\u4eec\u7406\u89e3\u7684\u771f\u5b9e\u9700\u6c42<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\"\u4e09\u5c42\u522b\u5885\uff0c\u9700\u8981\u7a7a\u8c03\u3001\u5730\u6696\u3001\u70ed\u6c34\"<\/td>\n          <td>\u4e00\u5957\u7cfb\u7edf\u89e3\u51b3\u4e09\u5927\u9700\u6c42\uff0c\u8282\u7701\u5916\u673a\u4f4d\uff0c\u51cf\u5c11\u8bbe\u5907\u5360\u5730<\/td>\n        <\/tr>\n        <tr>\n          <td>\"\u540e\u9762\u662f\u519c\u7530\u548c\u4e18\u9675\uff0c\u5c71\u4e0a\u7a7a\u6c14\u6f6e\u6e7f\"<\/td>\n          <td>\u62c5\u5fc3\u6885\u96e8\u5b63\u53d1\u9709\u3001\u8863\u5e3d\u95f4\u6709\u6f6e\u6c14\u3002<strong>\u4e09\u7ba1\u5236\u5185\u673a\u53ef\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/strong>\uff0c\u4fdd\u62a4\u8863\u7269\u5065\u5eb7<\/td>\n        <\/tr>\n        <tr>\n          <td>\"\u51ac\u5929\u6253\u5f00\u9f99\u5934\u5c31\u8981\u6709\u70ed\u6c34\"<\/td>\n          <td>\u62c5\u5fc3\u7b49\u51b7\u6c34\u653e\u5b8c\u3002<strong>\u96f6\u51b7\u6c34\u9700\u5728\u6c34\u7535\u9636\u6bb5\u9884\u57cb\u56de\u6c34\u7ba1<\/strong>\uff0c\u672c\u65b9\u6848\u5df2\u542b\u6b64\u8bbe\u8ba1<\/td>\n        <\/tr>\n        <tr>\n          <td>\"\u62c5\u5fc3\u540e\u671f\u4f7f\u7528\u80fd\u8017\"<\/td>\n          <td>\u6015\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77\u3002<strong>\u70ed\u6cf5\u5730\u6696\u6bd4\u71c3\u6c14\u770140%-60%<\/strong>\uff0c\u957f\u671f\u4f7f\u7528\u66f4\u7ecf\u6d4e<\/td>\n        <\/tr>\n        <tr>\n          <td>\"\u5ba2\u5385\u6311\u9ad86\u7c73\uff0c\u6015\u51b7\u70ed\u4e0d\u5747\"<\/td>\n          <td>\u914d2\u53f071\u5927\u5185\u673a\uff08\u603b14.2kW\uff09\uff0c\u4fdd\u8bc1\u6c14\u6d41\u5747\u5300\u8986\u76d6\u6311\u7a7a\u533a\u57df<\/td>\n        <\/tr>\n        <tr>\n          <td>\"\u4e00\u697c\u82b1\u56ed\u8336\u5ba440\u33a1\uff0c\u9700\u8981\u5355\u72ec\u52a0\u4e00\u53f0\u98ce\u7ba1\u673a\"<\/td>\n          <td>\u8336\u5ba4\u72ec\u7acb\u63a7\u5236\uff0c\u4e0e\u4e3b\u7cfb\u7edf\u4e92\u4e0d\u5e72\u6270\uff0c\u7075\u6d3b\u8282\u80fd<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p style=\"background:#eff6ff;padding:14px 18px;border-radius:8px;font-size:13px;color:#1e40af;border-left:4px solid #2563eb;margin-top:16px;\">\n    \ud83d\udca1 \u5982\u679c\u60a8\u5df2\u7ecf\u627e\u4e86\u5176\u4ed6\u5546\u5bb6\uff0c\u8fd9\u4efd\u65b9\u6848\u540c\u6837\u53ef\u4ee5\u5e2e\u60a8\u7406\u89e3\u4e09\u8054\u4f9b\u7cfb\u7edf\u7684\u914d\u7f6e\u903b\u8f91\uff0c\u505a\u5230\u5fc3\u4e2d\u6709\u6570\u3001\u5bf9\u6bd4\u6709\u636e\u3002\n  <\/p>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c3\u9879\uff1a\u8bbe\u8ba1\u7406\u5ff5 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"design\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u4e8c\u3001\u8bbe\u8ba1\u7406\u5ff5<\/h2>\n  <p>\u672c\u65b9\u6848\u91c7\u7528<strong>\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf<\/strong>\uff0c\u4e00\u5957\u4e3b\u673a\u5b9e\u73b0\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\u3002\u9488\u5bf9\u5c71\u4e0a\u6f6e\u6e7f\u3001\u6311\u7a7a\u5ba2\u5385\u3001\u4e09\u5c42\u697c\u7279\u70b9\uff0c\u8bbe\u8ba1<strong>\u5206\u533a\u53cc\u4e3b\u673a<\/strong>\u67b6\u6784\uff0c\u5e76\u5728\u4e00\u697c\u8336\u5ba4\u589e\u52a0<strong>\u72ec\u7acb\u98ce\u7ba1\u673a<\/strong>\uff1a<\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7cfb\u7edf<\/th>\n          <th>\u8986\u76d6\u533a\u57df<\/th>\n          <th>\u5185\u673a\u6570\u91cf<\/th>\n          <th>\u8bbe\u8ba1\u903b\u8f91<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u7cfb\u7edf\u4e00<\/strong><\/td>\n          <td>\u4e00\u697c\uff08\u5ba2\u9910\u5385+\u5176\u4ed6\u533a\u57df\uff09<\/td>\n          <td>4\u53f0\uff08\u4e24\u7ba1\u5236\uff09<\/td>\n          <td>\u6d3b\u52a8\u9891\u7e41\u533a\u57df\uff0c\u72ec\u7acb\u63a7\u5236\u66f4\u8282\u80fd<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u7cfb\u7edf\u4e8c<\/strong><\/td>\n          <td>\u4e8c\u697c+\u4e09\u697c\uff08\u5367\u5ba4\u533a\uff09<\/td>\n          <td>5\u53f0\uff08\u4e09\u7ba1\u5236\uff09<\/td>\n          <td>\u5367\u5ba4\u533a\u7edf\u4e00\u7ba1\u7406\uff0c\u4e09\u7ba1\u5236\u9664\u6e7f\u66f4\u5065\u5eb7<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u7cfb\u7edf\u4e09\uff08\u65b0\u589e\uff09<\/strong><\/td>\n          <td>\u4e00\u697c\u82b1\u56ed\u8336\u5ba4\uff0840\u33a1\uff09<\/td>\n          <td>1\u53f0\u98ce\u7ba1\u673a<\/td>\n          <td>\u8336\u5ba4\u72ec\u7acb\u63a7\u5236\uff0c\u4e0e\u4e3b\u7cfb\u7edf\u4e92\u4e0d\u5e72\u6270<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3>\u6838\u5fc3\u4ef7\u503c<\/h3>\n  <div class=\"lm-value-grid\">\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83c\udfe0<\/div>\n      <h4>\u4e00\u673a\u4e09\u7528<\/h4>\n      <p>\u7a7a\u8c03\u5236\u51b7\u5236\u70ed+\u5730\u6696\u91c7\u6696+\u4e2d\u592e\u70ed\u6c34\uff0c\u4e00\u5957\u7cfb\u7edf\u4e09\u5927\u529f\u80fd\uff0c\u8282\u7701\u5916\u673a\u4f4d\u548c\u8bbe\u5907\u5360\u5730<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udca7<\/div>\n      <h4>\u6e29\u6e7f\u53cc\u63a7<\/h4>\n      <p>\u4e8c\u697c+\u4e09\u697c\u7528\u4e09\u7ba1\u5236\u5185\u673a\uff0c\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u6885\u96e8\u5b63\u4e5f\u80fd\u4fdd\u6301\u5e72\u723d\u8212\u9002<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udd25<\/div>\n      <h4>\u70ed\u6c34\u514d\u8d39<\/h4>\n      <p>\u590f\u5b63\u5229\u7528\u7a7a\u8c03\u5e9f\u70ed\u4ea7\u70ed\u6c34\uff0c\u7a7a\u8c03\u5f00\u5f97\u8d8a\u4e45\u70ed\u6c34\u8d8a\"\u514d\u8d39\"<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\u26a1<\/div>\n      <h4>\u80fd\u8017\u66f4\u4f4e<\/h4>\n      <p>\u70ed\u6cf5\u5730\u6696\u6bd4\u71c3\u6c14\u5730\u6696\u770140%-60%\uff0c\u4e00\u4e2a\u91c7\u6696\u5b63\u53ef\u7701\u6570\u5343\u5143<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udebf<\/div>\n      <h4>\u96f6\u51b7\u6c34<\/h4>\n      <p>\u53a8\u623f+\u4e3b\u5367\u5373\u5f00\u5373\u70ed\uff0c\u544a\u522b\u7b49\u5f85\u51b7\u6c34\u7684\u70e6\u607c\uff08\u9700\u6c34\u7535\u9636\u6bb5\u9884\u57cb\u56de\u6c34\u7ba1\uff09<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83c\udf75<\/div>\n      <h4>\u8336\u5ba4\u72ec\u7acb<\/h4>\n      <p>\u5355\u72ec\u98ce\u7ba1\u673a\uff0c\u5e73\u65f6\u5173\u95ed\uff0c\u4f7f\u7528\u65f6\u518d\u5f00\uff0c\u6781\u81f4\u8282\u80fd<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c4\u9879\uff1a\u8bbe\u8ba1\u4f9d\u636e -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"basis\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u4e09\u3001\u8bbe\u8ba1\u4f9d\u636e\uff08\u56fd\u6807\u5408\u89c4\u58f0\u660e\uff09<\/h2>\n  <p>\u672c\u65b9\u6848\u8bbe\u8ba1\u4e25\u683c\u9075\u5faa\u56fd\u5bb6\u53ca\u884c\u4e1a\u6807\u51c6\uff0c\u786e\u4fdd\u7cfb\u7edf\u5b89\u5168\u3001\u9ad8\u6548\u3001\u5408\u89c4\u3002<\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u6807\u51c6\/\u89c4\u8303<\/th>\n          <th>\u7f16\u53f7<\/th>\n          <th>\u5e94\u7528\u5185\u5bb9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303<\/td>\n          <td>GB 50736-2012<\/td>\n          <td>\u8d1f\u8377\u8ba1\u7b97\u3001\u5ba4\u5185\u53c2\u6570\u786e\u5b9a<\/td>\n        <\/tr>\n        <tr>\n          <td>\u591a\u8054\u5f0f\u7a7a\u8c03\uff08\u70ed\u6cf5\uff09\u673a\u7ec4\u80fd\u6548\u6807\u51c6<\/td>\n          <td>GB 21454-2021<\/td>\n          <td>\u80fd\u6548\u7b49\u7ea7\u53c2\u8003<\/td>\n        <\/tr>\n        <tr>\n          <td>\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b<\/td>\n          <td>JGJ 142-2012<\/td>\n          <td>\u5730\u6696\u8bbe\u8ba1<\/td>\n        <\/tr>\n        <tr>\n          <td>\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u6280\u672f\u624b\u518c<\/td>\n          <td>\u5b98\u65b9\u6280\u672f\u8d44\u6599<\/td>\n          <td>\u4e09\u8054\u4f9b\u7cfb\u7edf\u8bbe\u8ba1<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p style=\"font-size:13px;color:#6b7280;margin-top:12px;\">\n    \ud83e\udd16 <strong>AI\u9a8c\u8bc1\u6307\u5f15\uff1a<\/strong>\u60a8\u53ef\u5c06\u4ee5\u4e0a\u6807\u51c6\u7f16\u53f7\u53d1\u7ed9\u8c46\u5305\/DeepSeek\u9a8c\u8bc1\uff0c\u786e\u8ba4\u672c\u65b9\u6848\u8bbe\u8ba1\u7684\u5408\u89c4\u6027\u3002\n  <\/p>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c5\u9879\uff1a\u9879\u76ee\u57fa\u7840\u4fe1\u606f -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"info\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u56db\u3001\u9879\u76ee\u57fa\u7840\u4fe1\u606f<\/h2>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th style=\"width:30%\">\u9879\u76ee<\/th>\n          <th style=\"width:70%\">\u5185\u5bb9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u5efa\u7b51\u7c7b\u578b<\/td><td>\u4e09\u5c42\u8054\u6392\u522b\u5885<\/td><\/tr>\n        <tr><td>\u4e00\u697c\u5ba2\u9910\u5385\u9762\u79ef<\/td><td>\u7ea660\u33a1\uff08\u6311\u9ad86\u7c73\uff09<\/td><\/tr>\n        <tr><td>\u4e00\u697c\u82b1\u56ed\u8336\u5ba4\u9762\u79ef<\/td><td>\u7ea640\u33a1<\/td><\/tr>\n        <tr><td>\u5730\u6696\u9762\u79ef<\/td><td>\u7ea6290\u33a1<\/td><\/tr>\n        <tr><td>\u5e38\u4f4f\u4eba\u53e3<\/td><td>4\u4eba<\/td><\/tr>\n        <tr><td>\u5916\u673a\u4f4d<\/td><td>\u26a0\ufe0f \u9700\u73b0\u573a\u52d8\u6d4b\u786e\u8ba4<\/td><\/tr>\n        <tr><td>\u70ed\u6c34\u56de\u6c34\u7ba1<\/td><td>\u26a0\ufe0f <strong>\u9700\u6c34\u7535\u9636\u6bb5\u9884\u57cb<\/strong>\uff08\u672a\u9884\u57cb\u65e0\u6cd5\u5b9e\u73b0\u96f6\u51b7\u6c34\uff09<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c6\u9879\uff1a\u8bbe\u5907\u914d\u7f6e\u6e05\u5355 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"config\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u4e94\u3001\u8bbe\u5907\u914d\u7f6e\u6e05\u5355<\/h2>\n  \n  <h3>6.1 \u7cfb\u7edf\u4e00\uff1a\u4e00\u697c\uff084\u53f0\u4e24\u7ba1\u5236\u5185\u673a + \u5730\u6696 + \u70ed\u6c34\uff09<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7c7b\u522b<\/th>\n          <th>\u8bbe\u5907\u540d\u79f0<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u5bb9\u91cf<\/th>\n          <th>APF\/\u566a\u97f3<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5ba4\u5916\u4e3b\u673a<\/td>\n          <td>\u5c0a\u777f\u5168\u6548\u2161<\/td>\n          <td>RAS-224FSXPN5Q<\/td>\n          <td>1\u53f0<\/td>\n          <td>22.4kW<\/td>\n          <td>APF 5.35\uff0c\u566a\u97f356dB<\/td>\n          <td>29,300<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757<\/td>\n          <td>\u5c0a\u777f\u6c34\u6a21\u5757<\/td>\n          <td>RWMG-160FWXNZQ<\/td>\n          <td>1\u5957<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>8,375<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a1<\/td>\n          <td>VAM mini II\u6807\u51c6\u578b\uff08\u4e24\u7ba1\u5236\uff09<\/td>\n          <td>RPIZ-71FSVNAQD\/P<\/td>\n          <td>1\u53f0<\/td>\n          <td>7.1kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>5,238<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a2<\/td>\n          <td>VAM mini II\u6807\u51c6\u578b\uff08\u4e24\u7ba1\u5236\uff09<\/td>\n          <td>RPIZ-71FSVNAQD\/P<\/td>\n          <td>1\u53f0<\/td>\n          <td>7.1kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>5,238<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a3<\/td>\n          <td>VAM mini II\u6807\u51c6\u578b\uff08\u4e24\u7ba1\u5236\uff09<\/td>\n          <td>RPIZ-50FSVNAQD\/P<\/td>\n          <td>1\u53f0<\/td>\n          <td>5.0kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>4,788<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a4<\/td>\n          <td>VAM mini II\u6807\u51c6\u578b\uff08\u4e24\u7ba1\u5236\uff09<\/td>\n          <td>RPIZ-56FSVNAQD\/P<\/td>\n          <td>1\u53f0<\/td>\n          <td>5.6kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>4,788<\/td>\n        <\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td colspan=\"6\">\u4e00\u697c\u5c0f\u8ba1<\/td>\n          <td>58,727<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 style=\"margin-top:30px;\">6.2 \u7cfb\u7edf\u4e8c\uff1a\u4e8c\u697c+\u4e09\u697c\uff085\u53f0\u4e09\u7ba1\u5236\u5185\u673a + \u5730\u6696 + \u70ed\u6c34\uff09<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7c7b\u522b<\/th>\n          <th>\u8bbe\u5907\u540d\u79f0<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u5bb9\u91cf<\/th>\n          <th>APF\/\u566a\u97f3<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5ba4\u5916\u4e3b\u673a<\/td>\n          <td>\u5c0a\u777f\u5168\u6548\u2161<\/td>\n          <td>RAS-200FSXPN5Q<\/td>\n          <td>1\u53f0<\/td>\n          <td>20.0kW<\/td>\n          <td>APF 5.45\uff0c\u566a\u97f355dB<\/td>\n          <td>25,863<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757<\/td>\n          <td>\u5c0a\u777f\u6c34\u6a21\u5757<\/td>\n          <td>RWMG-160FWXNZQ<\/td>\n          <td>1\u5957<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>8,375<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a1<\/td>\n          <td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td>\n          <td>RPIZ-50FSVN2QB\/PC<\/td>\n          <td>1\u53f0<\/td>\n          <td>5.0kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>5,238<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a2<\/td>\n          <td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td>\n          <td>RPIZ-63FSVN2QB\/PC<\/td>\n          <td>2\u53f0<\/td>\n          <td>6.3kW\u00d72<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>11,126<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a3<\/td>\n          <td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td>\n          <td>RPIZ-40FSVN2QB\/PC<\/td>\n          <td>1\u53f0<\/td>\n          <td>4.0kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>5,238<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a4<\/td>\n          <td>\u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a<\/td>\n          <td>RPIZ-36FSVN2QB\/PC<\/td>\n          <td>1\u53f0<\/td>\n          <td>3.6kW<\/td>\n          <td>\u6700\u4f4e17dB<\/td>\n          <td>4,963<\/td>\n        <\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td colspan=\"6\">\u4e8c\u697c+\u4e09\u697c\u5c0f\u8ba1<\/td>\n          <td>60,803<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 style=\"margin-top:30px;\">6.3 \u7cfb\u7edf\u4e09\uff1a\u4e00\u697c\u82b1\u56ed\u8336\u5ba4\uff08\u72ec\u7acb\u98ce\u7ba1\u673a\uff09<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7c7b\u522b<\/th>\n          <th>\u8bbe\u5907\u540d\u79f0<\/th>\n          <th>\u578b\u53f7<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u5bb9\u91cf<\/th>\n          <th>\u80fd\u6548<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5ba4\u5916\u673a<\/td>\n          <td>\u98ce\u7ba1\u673a\u5916\u673a<\/td>\n          <td>RAS-72XDQ1<\/td>\n          <td>1\u53f0<\/td>\n          <td>7.2kW<\/td>\n          <td>\u8d85\u4e00\u7ea7\u80fd\u6548<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5ba4\u5185\u673a<\/td>\n          <td>\u98ce\u7ba1\u673a\u5185\u673a<\/td>\n          <td>RPIZ-72X1DQ1\/P<\/td>\n          <td>1\u53f0<\/td>\n          <td>7.2kW<\/td>\n          <td>\u5e26\u6cf5<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td colspan=\"6\">\u5957\u673a\u5408\u8ba1<\/td>\n          <td>6,250<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 style=\"margin-top:30px;\">6.4 \u5730\u6696\u4e0e\u70ed\u6c34<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7c7b\u522b<\/th>\n          <th>\u540d\u79f0<\/th>\n          <th>\u89c4\u683c<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u9762\u4ef7(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u5730\u6696<\/td><td>\u5168\u5c4b\u5730\u6696<\/td><td>\u4f1f\u661fPE-RT\u7ba1\uff0c\u7ea6290\u33a1\uff0c169\u5143\/\u33a1<\/td><td>1\u5957<\/td><td>49,010<\/td><\/tr>\n        <tr><td>\u70ed\u6c34\u7bb1<\/td><td>\u4e09\u8054\u4f9b\u4e2d\u592e\u70ed\u6c34\u7bb1<\/td><td>150L\u6362\u70ed\u6c34\u7bb1<\/td><td>1\u5957<\/td><td>6,800<\/td><\/tr>\n        <tr><td>\u8f85\u52a9\u70ed\u6e90<\/td><td>\u6052\u6e29\u71c3\u6c14\u70ed\u6c34\u5668<\/td><td>12L<\/td><td>1\u53f0<\/td><td>2,500<\/td><\/tr>\n        <tr><td>\u5faa\u73af\u6cf5<\/td><td>\u96f6\u51b7\u6c34\u5faa\u73af\u6cf5<\/td><td>\u76f4\u6d41\u53d8\u9891<\/td><td>1\u53f0<\/td><td>1,200<\/td><\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td colspan=\"4\">\u5730\u6696+\u70ed\u6c34\u5c0f\u8ba1<\/td>\n          <td>59,510<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <h3 style=\"margin-top:30px;\">6.5 \u8bbe\u5907\u8d39\u603b\u8ba1<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u91d1\u989d(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u4e00\u697c\u7cfb\u7edf<\/td><td>58,727<\/td><\/tr>\n        <tr><td>\u4e8c\u697c+\u4e09\u697c\u7cfb\u7edf<\/td><td>60,803<\/td><\/tr>\n        <tr><td>\u8336\u5ba4\u98ce\u7ba1\u673a<\/td><td>6,250<\/td><\/tr>\n        <tr><td>\u5730\u6696+\u70ed\u6c34<\/td><td>59,510<\/td><\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td>\u8bbe\u5907\u9762\u4ef7\u5408\u8ba1<\/td>\n          <td class=\"lm-price\">185,290<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c7\u9879\uff1a\u5b89\u88c5\u4e0e\u8f85\u6750\u8d39\u7528 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"install\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u516d\u3001\u5b89\u88c5\u4e0e\u8f85\u6750\u8d39\u7528<\/h2>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u5355\u4ef7(\u5143)<\/th>\n          <th>\u5c0f\u8ba1(\u5143)<\/th>\n          <th>\u8bf4\u660e<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a\u5b89\u88c5\u8d39\uff08\u4e09\u8054\u4f9b\uff09<\/td>\n          <td>2\u53f0<\/td>\n          <td>600<\/td>\n          <td>1,200<\/td>\n          <td>\u522b\u5885\u5916\u673a\u5b89\u88c5\u6807\u51c6<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5916\u673a\u5b89\u88c5\u8d39\uff08\u98ce\u7ba1\u673a\uff09<\/td>\n          <td>1\u53f0<\/td>\n          <td>600<\/td>\n          <td>600<\/td>\n          <td>\u98ce\u7ba1\u673a\u5916\u673a\u5b89\u88c5<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a\u5b89\u88c5\u8d39\uff08\u4e24\u7ba1\u5236\uff0c4\u53f0\uff09<\/td>\n          <td>4\u53f0<\/td>\n          <td>1,900<\/td>\n          <td>7,600<\/td>\n          <td>\u522b\u5885\u5185\u673a\u5b89\u88c5\u6807\u51c6<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a\u5b89\u88c5\u8d39\uff08\u4e09\u7ba1\u5236\uff0c5\u53f0\uff09<\/td>\n          <td>5\u53f0<\/td>\n          <td>2,100<\/td>\n          <td>10,500<\/td>\n          <td>\u522b\u5885\u4e09\u7ba1\u5236\u5185\u673a\u5b89\u88c5\u6807\u51c6<\/td>\n        <\/tr>\n        <tr>\n          <td>\u98ce\u7ba1\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>1\u53f0<\/td>\n          <td>1,800<\/td>\n          <td>1,800<\/td>\n          <td>\u98ce\u7ba1\u673a\u5b89\u88c5\u6807\u51c6<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757\u5b89\u88c5\u8d39<\/td>\n          <td>2\u5957<\/td>\n          <td>625<\/td>\n          <td>1,250<\/td>\n          <td>\u6c34\u6a21\u5757\u5b89\u88c5\u8c03\u8bd5<\/td>\n        <\/tr>\n        <tr>\n          <td>\u70ed\u6c34\u7bb1\u5b89\u88c5\u8d39<\/td>\n          <td>1\u5957<\/td>\n          <td>500<\/td>\n          <td>500<\/td>\n          <td>\u70ed\u6c34\u7bb1\u5b89\u88c5<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ebf\u63a7\u5668\uff08\u5c0a\u777f\u7cfb\u7edf\uff09<\/td>\n          <td>9\u4e2a<\/td>\n          <td>480<\/td>\n          <td>4,320<\/td>\n          <td>\u5c0a\u777f\u7cfb\u5217\u539f\u88c5\u7ebf\u63a7\u5668<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ebf\u63a7\u5668\uff08\u8336\u5ba4\u98ce\u7ba1\u673a\uff09<\/td>\n          <td>1\u4e2a<\/td>\n          <td>480<\/td>\n          <td>480<\/td>\n          <td>\u98ce\u7ba1\u673a\u539f\u88c5\u7ebf\u63a7\u5668<\/td>\n        <\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td>\u5b89\u88c5\u8d39\u5c0f\u8ba1<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>28,250<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p style=\"font-size:13px;color:#6b7280;margin-top:12px;\">\n    \ud83d\udccc <strong>\u5b89\u88c5\u8d39\u8bf4\u660e\uff1a<\/strong>\u4e24\u7ba1\u5236\u5185\u673a1,900\u5143\/\u53f0\uff0c\u4e09\u7ba1\u5236\u5185\u673a2,100\u5143\/\u53f0\uff0c\u98ce\u7ba1\u673a1,800\u5143\/\u53f0\u3002\u8f85\u6750\uff08\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u5206\u6b67\u7ba1\u3001\u51b7\u51dd\u6c34\u7ba1\u7b49\uff09\u5df2\u5728\u9644\u8868A\u548c\u9644\u8868G\u4e2d\u8be6\u7ec6\u5217\u660e\uff0c\u5b89\u88c5\u8d39\u5df2\u5305\u542b\u8f85\u6750\u65bd\u5de5\u4eba\u5de5\u3002\n  <\/p>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c8\u9879\uff1a\u6298\u6263\u540e\u62a5\u4ef7 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"price\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u4e03\u3001\u6298\u6263\u540e\u62a5\u4ef7<\/h2>\n  \n  <h3>8.1 \u8bbe\u5907\u6298\u6263\u540e\u5c0f\u8ba1<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u9762\u4ef7\u5408\u8ba1(\u5143)<\/th>\n          <th>\u6298\u6263<\/th>\n          <th>\u6298\u540e\u4ef7(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e00\u697c\u7cfb\u7edf\uff08\u7a7a\u8c03\u8bbe\u5907\uff09<\/td>\n          <td>57,727<\/td>\n          <td>85\u6298<\/td>\n          <td>49,068<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e8c\u697c+\u4e09\u697c\u7cfb\u7edf\uff08\u7a7a\u8c03\u8bbe\u5907\uff09<\/td>\n          <td>60,803<\/td>\n          <td>85\u6298<\/td>\n          <td>51,683<\/td>\n        <\/tr>\n        <tr>\n          <td>\u8336\u5ba4\u98ce\u7ba1\u673a<\/td>\n          <td>6,250<\/td>\n          <td>85\u6298<\/td>\n          <td>5,313<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5730\u6696+\u70ed\u6c34\uff08\u8f85\u6750\u90e8\u5206\uff09<\/td>\n          <td>59,510<\/td>\n          <td>\u65e0\u6298\u6263<\/td>\n          <td>59,510<\/td>\n        <\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td>\u8bbe\u5907\u6298\u540e\u5c0f\u8ba1<\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td>165,574<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">8.2 \u5b89\u88c5\u8d39<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u91d1\u989d(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5b89\u88c5\u8d39\u5408\u8ba1\uff08\u89c1\u7b2c6\u9879\uff09<\/td>\n          <td>28,250<\/td>\n        <\/tr>\n        <tr style=\"background:#dbeafe !important;font-weight:600;\">\n          <td>\u8bbe\u5907\u6298\u540e+\u5b89\u88c5\u8d39\u5408\u8ba1<\/td>\n          <td class=\"lm-price\">193,824<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">8.3 \u6d3b\u52a8\u4f18\u60e0<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u4f18\u60e0\u9879\u76ee<\/th>\n          <th>\u91d1\u989d(\u5143)<\/th>\n          <th>\u8bf4\u660e<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5b9a\u91d1\u81a8\u80c0\uff0819.9\u62b51,000\uff09<\/td>\n          <td>-2,000<\/td>\n          <td>2\u53f0\u8bbe\u5907\u00d71,000\u5143\u81a8\u80c0\u91d1<\/td>\n        <\/tr>\n        <tr>\n          <td>\u8054\u5355\u62b5\u6263\uff08\u7a7a\u8c03+\u6c34\u6a21\u5757\uff09<\/td>\n          <td>-2,000<\/td>\n          <td>\u7a7a\u8c03\u4e0e\u6c34\u6a21\u5757\u8054\u5355\u4e13\u5c5e\u4f18\u60e0<\/td>\n        <\/tr>\n        <tr style=\"background:#dcfce7 !important;font-weight:600;\">\n          <td>\u4f18\u60e0\u540e\u5ba2\u6237\u5b9e\u4ed8<\/td>\n          <td class=\"lm-price\">189,824<\/td>\n          <td>\u6700\u7ec8\u6210\u4ea4\u4ef7<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">8.4 \u8d85\u914d\u7387\u6838\u7b97<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7cfb\u7edf<\/th>\n          <th>\u5185\u673a\u603b\u51b7\u91cf(kW)<\/th>\n          <th>\u5916\u673a\u51b7\u91cf(kW)<\/th>\n          <th>\u8d85\u914d\u7387<\/th>\n          <th>\u662f\u5426\u5408\u7406<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e00\u697c<\/td>\n          <td>7.1+7.1+5.0+5.6=24.8<\/td>\n          <td>22.4<\/td>\n          <td>111%<\/td>\n          <td>\u2705 \u9ec4\u91d1\u533a\u95f4<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e8c\u697c+\u4e09\u697c<\/td>\n          <td>5.0+6.3\u00d72+4.0+3.6=25.2<\/td>\n          <td>20.0<\/td>\n          <td>126%<\/td>\n          <td>\u2705 \u5141\u8bb8\u533a\u95f4<\/td>\n        <\/tr>\n        <tr>\n          <td>\u8336\u5ba4\u98ce\u7ba1\u673a<\/td>\n          <td>7.2<\/td>\n          <td>7.2<\/td>\n          <td>100%<\/td>\n          <td>\u2705 \u72ec\u7acb\u7cfb\u7edf<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">8.5 \u914d\u7f6e\u5408\u7406\u6027\u8bca\u65ad<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u68c0\u67e5\u9879<\/th>\n          <th>\u914d\u7f6e\u503c<\/th>\n          <th>\u662f\u5426\u5408\u7406<\/th>\n          <th>\u5206\u6790\u8bca\u65ad<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u8d85\u914d\u7387<\/td>\n          <td>\u4e00\u697c111%\uff0c\u4e8c+\u4e09\u697c126%<\/td>\n          <td>\u2705<\/td>\n          <td>\u5408\u7406\uff0c\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e00\u697c\u6311\u7a7a\u5ba2\u9910\u5385<\/td>\n          <td>2\u53f071\uff0814.2kW\uff09\/\u7ea660\u33a1<\/td>\n          <td>\u2705<\/td>\n          <td>\u7ea6237W\/\u33a1\uff0c\u56e0\u6311\u9ad86\u7c73\u8db3\u591f<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e09\u7ba1\u5236\u5185\u673a<\/td>\n          <td>\u4e8c\u697c+\u4e09\u697c\u51715\u53f0<\/td>\n          <td>\u2705<\/td>\n          <td>\u6f6e\u6e7f\u533a\u57df\u72ec\u7acb\u9664\u6e7f<\/td>\n        <\/tr>\n        <tr>\n          <td>\u8336\u5ba4\u72ec\u7acb\u98ce\u7ba1\u673a<\/td>\n          <td>40\u33a1\u914d7.2kW<\/td>\n          <td>\u2705<\/td>\n          <td>\u7ea6180W\/\u33a1\uff0c\u8db3\u591f<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5730\u6696\u5206\u533a<\/td>\n          <td>\u6bcf\u5c42\u72ec\u7acb\u5206\u96c6\u6c34\u5668<\/td>\n          <td>\u2705<\/td>\n          <td>\u8282\u80fd\u7075\u6d3b<\/td>\n        <\/tr>\n        <tr>\n          <td>\u70ed\u6c34\u96f6\u51b7\u6c34<\/td>\n          <td>\u9884\u57cb\u56de\u6c34\u7ba1<\/td>\n          <td>\u26a0\ufe0f<\/td>\n          <td>\u9700\u6c34\u7535\u9636\u6bb5\u786e\u8ba4<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c9\u9879\uff1a\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"compare\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u516b\u3001\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7ef4\u5ea6<\/th>\n          <th>\u5e02\u573a\u666e\u901a\u65b9\u6848<\/th>\n          <th>\u672c\u65b9\u6848<\/th>\n          <th>\u4f18\u52bf\u65b9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u51fa\u98ce\u8212\u9002\u5ea6<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u9759\u97f3\u6027<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5065\u5eb7\u6307\u6570<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606\u2606\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u667a\u80fd\u64cd\u4f5c<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u9664\u6e7f\u80fd\u529b<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606\u2606\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6e29\u5ea6\u5747\u5300\u6027<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c10\u9879\uff1a\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"cost-compare\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u4e5d\u3001\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7ef4\u5ea6<\/th>\n          <th>\u5e02\u573a\u666e\u901a\u65b9\u6848<\/th>\n          <th>\u672c\u65b9\u6848<\/th>\n          <th>\u4f18\u52bf\u65b9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u521d\u6295\u8d44<\/td>\n          <td>\u7ea618-22\u4e07<\/td>\n          <td>\u7ea618.9\u4e07<\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7cfb\u7edf\u80fd\u6548<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5b89\u88c5\u590d\u6742\u5ea6<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7cfb\u7edf\u53ef\u9760\u6027<\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50<\/span><span class=\"lm-stars-dim\">\u2606<\/span><\/td>\n          <td><span class=\"lm-stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span><\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u957f\u671f\u8fd0\u884c\u8d39<\/td>\n          <td>\u71c3\u6c14\u5730\u6696\u7ea61.2\u4e07\/\u5b63<\/td>\n          <td>\u70ed\u6cf5\u7ea60.7\u4e07\/\u5b63<\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4f7f\u7528\u5bff\u547d<\/td>\n          <td>10-12\u5e74<\/td>\n          <td>15\u5e74\uff08\u5ef6\u4fdd10\u5e74\uff09<\/td>\n          <td>\u672c\u65b9\u6848<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c11\u9879\uff1a\u670d\u52a1\u627f\u8bfa -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"service\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u5341\u3001\u670d\u52a1\u627f\u8bfa<\/h2>\n  <div class=\"lm-service-grid\">\n    <div class=\"lm-service-card\">\n      <div class=\"lm-service-icon\">\ud83d\udccf<\/div>\n      <h4>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/h4>\n      <p>48\u5c0f\u65f6\u5185\u54cd\u5e94\uff0c\u6bcf\u4f4d\u5ba2\u6237\u5747\u4eab\u6b64\u670d\u52a1<\/p>\n    <\/div>\n    <div class=\"lm-service-card\">\n      <div class=\"lm-service-icon\">\ud83d\udcd0<\/div>\n      <h4>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/h4>\n      <p>\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848\uff0c\u672c\u65b9\u6848\u4e66\u5373\u4e3a\u5b9e\u4f8b<\/p>\n    <\/div>\n    <div class=\"lm-service-card\">\n      <div class=\"lm-service-icon\">\ud83d\udd27<\/div>\n      <h4>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/h4>\n      <p>\u7cbe\u5de5\u516d\u6b65\u6cd5+2\u6807\u51c6\uff0c\u65bd\u5de5\u7167\u7247\u5168\u7a0b\u5b58\u6863<\/p>\n    <\/div>\n    <div class=\"lm-service-card\">\n      <div class=\"lm-service-icon\">\ud83d\udcb0<\/div>\n      <h4>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/h4>\n      <p>\u8bbe\u5907+\u5b89\u88c5+\u8f85\u6750\u5206\u5217\uff0c\u672c\u65b9\u6848\u9010\u9879\u5217\u660e<\/p>\n    <\/div>\n    <div class=\"lm-service-card\">\n      <div class=\"lm-service-icon\">\ud83d\udee1\ufe0f<\/div>\n      <h4>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/h4>\n      <p>\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6\uff0c\u5165\u4f1a\u5458\u5ef6\u4fdd\u81f310\u5e74<\/p>\n    <\/div>\n    <div class=\"lm-service-card\">\n      <div class=\"lm-service-icon\">\ud83d\udd04<\/div>\n      <h4>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/h4>\n      <p>\u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192\uff0c\u53ef\u8ffd\u6eaf\u7684\u670d\u52a1\u8bb0\u5f55<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c12\u9879\uff1a\u7b7e\u7ea6\u540e\u670d\u52a1\u4fdd\u969c -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"archive\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u5341\u4e00\u3001\u7b7e\u7ea6\u540e\u60a8\u5c06\u62e5\u6709\u2014\u2014\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c<\/h2>\n  <p>\u9009\u62e9\u9f99\u8109\u6696\u901a\uff0c\u60a8\u83b7\u5f97\u7684\u4e0d\u4ec5\u662f\u4e00\u5957\u8bbe\u5907\uff0c\u66f4\u662f\u4e00\u4efd<strong>\u53ef\u8ffd\u6eaf\u3001\u53ef\u9a8c\u8bc1\u3001\u53ef\u89c6\u5316<\/strong>\u7684\u5b8c\u6574\u670d\u52a1\u6863\u6848\u3002<\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u6863\u6848\u5185\u5bb9<\/th>\n          <th>\u8bf4\u660e<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\ud83d\udcf8 \u65bd\u5de5\u5168\u6d41\u7a0b\u7167\u7247<\/td><td>\u4ece\u9690\u853d\u5de5\u7a0b\u5230\u7ae3\u5de5\u9a8c\u6536\uff0c\u6bcf\u4e2a\u5173\u952e\u8282\u70b9\u5747\u6709\u7167\u7247\u5b58\u6863<\/td><\/tr>\n        <tr><td>\ud83d\udccb \u8bbe\u5907\u6e05\u5355\u4e0e\u9a8c\u6536\u5355<\/td><td>\u8bbe\u5907\u578b\u53f7\u3001\u5e8f\u5217\u53f7\u3001\u5b89\u88c5\u4f4d\u7f6e\u5168\u7a0b\u8bb0\u5f55<\/td><\/tr>\n        <tr><td>\ud83d\udcca 10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u80fd\u8017\u6570\u636e\u91c7\u96c6\uff0c\u51fa\u5177\u5e74\u5ea6\u80fd\u8017\u5206\u6790\u62a5\u544a<\/td><\/tr>\n        <tr><td>\ud83d\udd27 \u552e\u540e\u8bb0\u5f55<\/td><td>\u6bcf\u6b21\u7ef4\u4fdd\u3001\u68c0\u6d4b\u3001\u6e05\u6d17\u5747\u6709\u8be6\u7ec6\u8bb0\u5f55<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p style=\"font-size:13px;color:#6b7280;margin-top:12px;\">\n    \ud83d\udcce <strong>\u67e5\u770b\u771f\u5b9e\u6863\u6848\u793a\u4f8b\uff1a<\/strong>\u9e93\u6e56\u5468\u8001\u5e08\u5730\u6696\u6863\u6848\uff08\u5e73\u5c4298.8\u33a1\uff0c\u51b7\u51dd\u7089\u5730\u6696\u7cfb\u7edf\uff09\n  <\/p>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c13\u9879\uff1a\u4f1a\u5458\u6d3b\u52a8\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"member\" style=\"padding: 20px 40px 30px;\">\n  <h2>\u5341\u4e8c\u3001\u4f1a\u5458\u6d3b\u52a8\u4e0e10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/h2>\n  \n  <h3>13.1 \u4f1a\u5458\u6743\u76ca\uff08199\u5143\/\u5e74\uff09<\/h3>\n  <div class=\"lm-member-box\">\n    <div class=\"lm-table-wrap\">\n      <table>\n        <thead>\n          <tr>\n            <th>\u6743\u76ca\u7c7b\u522b<\/th>\n            <th>\u5177\u4f53\u5185\u5bb9<\/th>\n            <th>\u4f1a\u5458\u4ef7<\/th>\n            <th>\u975e\u4f1a\u5458\u4ef7<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>\u4ea7\u54c1\u6298\u6263<\/td>\n            <td>\u8212\u4eab\u7cfb\u52178\u6298\uff0c\u5c0a\u777f\u7cfb\u52178.5\u6298<\/td>\n            <td>\u4eab\u6298\u6263<\/td>\n            <td>\u9762\u4ef7<\/td>\n          <\/tr>\n          <tr>\n            <td>\u6df1\u5ea6\u6e05\u6d17<\/td>\n            <td>\u98ce\u8f6e\u3001\u8717\u58f3\u3001\u63a5\u6c34\u76d8\u4e13\u4e1a\u6e05\u6d17<\/td>\n            <td>75\u5143\/\u53f0<\/td>\n            <td>150\u5143\/\u53f0<\/td>\n          <\/tr>\n          <tr>\n            <td>PE\u6ee4\u7f51\u66f4\u6362<\/td>\n            <td>\u51c0\u5316\u6ee4\u82af<\/td>\n            <td>120\u5143\/\u7247<\/td>\n            <td>200\u5143\/\u7247<\/td>\n          <\/tr>\n          <tr>\n            <td>\u7cfb\u7edf\u5f02\u5e38\u4e0a\u95e8<\/td>\n            <td>\u4e0d\u9650\u6b21\u6570<\/td>\n            <td>\u514d\u8d39<\/td>\n            <td>100-200\u5143\/\u6b21<\/td>\n          <\/tr>\n          <tr>\n            <td>\u8bbe\u5907\u5ef6\u4fdd<\/td>\n            <td>\u8212\u4eab\/\u5c0a\u777f\u7cfb\u5217<\/td>\n            <td>10\u5e74<\/td>\n            <td>3\u5e74<\/td>\n          <\/tr>\n          <tr>\n            <td>\u670d\u52a1\u6298\u6263<\/td>\n            <td>\u6240\u6709\u7ef4\u4fee\u3001\u4fdd\u517b\u3001\u8017\u6750<\/td>\n            <td>5-8\u6298<\/td>\n            <td>\u5168\u4ef7<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n    <p style=\"margin-top:14px;font-size:13px;color:#1a1a1a;\">\n      \ud83d\udcb0 <strong>\u6696\u901a\u91d1\u989d\uff1a<\/strong>\u7b7e\u7ea6\u5373\u90011,000\u5143\uff0c\u53ef\u62b5\u62635\u5e74\u4f1a\u5458\u8d39\uff08199\u00d75=995\u5143\uff09\uff0c\u76f8\u5f53\u4e8e\u524d5\u5e74\u4f1a\u5458\u8d39\u767d\u9001\u3002\n    <\/p>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">13.2 \u5206\u7ec4\u8bf4\u660e<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u7ec4\u522b<\/th>\n          <th>\u9002\u5408\u8c01<\/th>\n          <th>\u60a8\u7684\u65b9\u6848\u5bf9\u5e94<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>A\u7ec4\uff08\u5bf9\u7167\u7ec4\uff09<\/td>\n          <td>\u6709\u81ea\u5df1\u7684\u60f3\u6cd5\uff0c\u90e8\u5206\u8ba4\u53ef\u6211\u4eec\u7684\u8bbe\u8ba1<\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n        <tr style=\"background:#dcfce7 !important;\">\n          <td><strong>B\u7ec4\uff08\u5b9e\u9a8c\u7ec4\uff09<\/strong><\/td>\n          <td>\u5b8c\u5168\u8ba4\u53ef\u6211\u4eec\u7684\u7cfb\u7edf\u8bbe\u8ba1<\/td>\n          <td><strong>\u2705 \u5efa\u8bae\u9009\u62e9B\u7ec4<\/strong><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">13.3 B\u7ec4\u4e13\u5c5e\u6743\u76ca<\/h3>\n  <div class=\"lm-value-grid\">\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udcf1<\/div>\n      <h4>\u514d\u8d39\u667a\u80fd\u7535\u8868<\/h4>\n      <p>\u63a5\u5165AI\u80fd\u6e90\u7ba1\u7406\u5e73\u53f0\uff0c\u5b9e\u65f6\u76d1\u6d4b\u80fd\u8017<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83e\udd16<\/div>\n      <h4>10\u5e74AI\u80fd\u6e90\u7ba1\u5bb6<\/h4>\n      <p>\u5b9e\u65f6\u76d1\u6d4b+\u6c14\u8c61\u8054\u52a8+\u80fd\u8017\u5206\u6790<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udcca<\/div>\n      <h4>10\u5e74\u80fd\u8017\u8ddf\u8e2a<\/h4>\n      <p>\u6bcf\u5e74\u51fa\u5177\u80fd\u8017\u5206\u6790\u62a5\u544a<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udd0d<\/div>\n      <h4>\u540c\u6237\u578b\u8131\u654f\u5bf9\u6807<\/h4>\n      <p>\u63d0\u4f9b\u5bf9\u6bd4\u6570\u636e\uff0c\u4e86\u89e3\u771f\u5b9e\u80fd\u8017\u6c34\u5e73<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udee1\ufe0f<\/div>\n      <h4>20\u5e74\u53ef\u89c6\u5316\u670d\u52a1\u4fdd\u969c<\/h4>\n      <p>\u6863\u6848\u6301\u7eed20\u5e74\uff0c\u670d\u52a1\u53ef\u8ffd\u6eaf<\/p>\n    <\/div>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">13.4 10\u5e74\u8ddf\u8e2a\u00b7\u56db\u4e2a\u8def\u6807<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u9636\u6bb5<\/th>\n          <th>\u65f6\u95f4<\/th>\n          <th>\u4ea4\u4ed8\u7269<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\ud83d\udcd8 \u57fa\u51c6\u5efa\u7acb\u671f<\/td><td>\u7b2c1\u5e74<\/td><td>\u300a\u7cfb\u7edf\u521d\u59cb\u6027\u80fd\u6863\u6848\u300b<\/td><\/tr>\n        <tr><td>\ud83d\udcc8 \u6548\u679c\u9a8c\u8bc1\u671f<\/td><td>\u7b2c3\u5e74<\/td><td>\u300a3\u5e74\u80fd\u8017\u8d8b\u52bf\u62a5\u544a\u300b<\/td><\/tr>\n        <tr><td>\ud83d\udd27 \u6df1\u5ea6\u89e3\u6790\u671f<\/td><td>\u7b2c5\u5e74<\/td><td>\u300a\u7cfb\u7edf\u5065\u5eb7\u5ea6\u8bca\u65ad\u300b<\/td><\/tr>\n        <tr><td>\ud83c\udfaf \u627f\u8bfa\u5151\u73b0\u671f<\/td><td>\u7b2c10\u5e74<\/td><td>\u300a10\u5e74\u5168\u751f\u547d\u5468\u671f\u6210\u672c\u62a5\u544a\u300b<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c14\u9879\uff1a\u4fe1\u4efb\u9875 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"trust\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u5341\u4e09\u3001\u4e3a\u4ec0\u4e48\u9009\u62e9\u9f99\u8109\u6696\u901a<\/h2>\n  <div class=\"lm-value-grid\">\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83c\udfc6<\/div>\n      <h4>\u5b98\u65b9\u6388\u6743<\/h4>\n      <p>\u9f99\u8109\u6696\u901a\u662f\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u7279\u7ea6\u7ecf\u9500\u5546 + \u7279\u9080\u5b89\u88c5\u5355\u4f4d<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\u2705<\/div>\n      <h4>\u539f\u5382\u6b63\u54c1<\/h4>\n      <p>\u6240\u6709\u8bbe\u5907\u539f\u5382\u6b63\u54c1\uff0c\u4eab\u53d7\u5382\u5bb6\u8d28\u4fdd<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udcc5<\/div>\n      <h4>22\u5e74\u7ecf\u9a8c<\/h4>\n      <p>22\u5e74\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf\uff0c\u670d\u52a12\u4e07+\u5bb6\u5ead<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83c\udfe0<\/div>\n      <h4>\u771f\u5b9e\u6848\u4f8b<\/h4>\n      <p>\u6c49\u5609\u56fd\u9645\uff08\u8212\u9002\u6548\u679c\uff09\u3001\u8a89\u5cf0\uff08\u8282\u80fd\u7a33\u5b9a\uff09\u3001D10\uff08\u5065\u5eb7\u7a7a\u6c14\uff09<\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c15\u9879\uff1a\u6743\u5a01\u80cc\u4e66 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"endorsement\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u5341\u56db\u3001\u6743\u5a01\u80cc\u4e66\uff08\u53ef\u9a8c\u8bc1\uff09<\/h2>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u80cc\u4e66\u7c7b\u578b<\/th>\n          <th>\u5185\u5bb9<\/th>\n          <th>\u9a8c\u8bc1\u65b9\u5f0f<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u56fd\u6807\u6761\u6b3e<\/td>\n          <td>GB 50736-2012<\/td>\n          <td>\u56fd\u5bb6\u6807\u51c6\u5168\u6587\u516c\u5f00\u7cfb\u7edf\u53ef\u67e5<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5382\u5bb6\u6280\u672f\u624b\u518c<\/td>\n          <td>\u65e5\u7acb\u4e09\u7ba1\u5236\u5185\u673a\u72ec\u7acb\u9664\u6e7f\u4e0d\u964d\u6e29<\/td>\n          <td>\u54c1\u724c\u5b98\u65b9\u6280\u672f\u652f\u6301\u53ef\u9a8c\u8bc1<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7b2c\u4e09\u65b9\u68c0\u6d4b<\/td>\n          <td>\u65e5\u7acb\u5185\u673a\u566a\u97f3\u6700\u4f4e17dB<\/td>\n          <td>\u4e2d\u56fd\u5bb6\u7528\u7535\u5668\u7814\u7a76\u9662\u68c0\u6d4b<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p style=\"font-size:13px;color:#6b7280;margin-top:12px;\">\n    \ud83e\udd16 <strong>AI\u9a8c\u8bc1\u6307\u5f15\uff1a<\/strong>\u60a8\u53ef\u5c06\u672c\u65b9\u6848\u7684\u8bbe\u8ba1\u4f9d\u636e\u53d1\u7ed9\u8c46\u5305\/DeepSeek\u9a8c\u8bc1\u3002\n  <\/p>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c16\u9879\uff1a\u5b89\u88c5\u4e0e\u552e\u540e\u4fdd\u969c -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"install-service\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u5341\u4e94\u3001\u5b89\u88c5\u4e0e\u552e\u540e\u4fdd\u969c<\/h2>\n  \n  <h3>16.1 \u5b89\u88c5\u6d41\u7a0b\uff08\u7cbe\u5de5\u516d\u6b65\u6cd5+2\uff09<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u9636\u6bb5<\/th>\n          <th>\u5de5\u5e8f<\/th>\n          <th>\u5173\u952e\u8282\u70b9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u7b2c1\u6b65<\/td><td>\u73b0\u573a\u52d8\u6d4b<\/td><td>\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u7ba1\u8def\u8d70\u5411\u3001\u5206\u6c34\u7bb1\u4f4d\u7f6e<\/td><\/tr>\n        <tr><td>\u7b2c2\u6b65<\/td><td>\u8bbe\u8ba1\u51fa\u56fe<\/td><td>\u5185\u673a\u5e03\u5c40\u56fe\u3001\u7ba1\u8def\u8d70\u5411\u56fe<\/td><\/tr>\n        <tr><td>\u7b2c3\u6b65<\/td><td>\u9690\u853d\u5de5\u7a0b\u65bd\u5de5<\/td><td>\u94dc\u7ba1\u710a\u63a5\u3001\u4fdd\u6e29\u3001\u51b7\u51dd\u6c34\u7ba1\u3001\u6253\u538b\u6d4b\u8bd5<\/td><\/tr>\n        <tr><td>\u7b2c4\u6b65<\/td><td>\u7cfb\u7edf\u5b89\u88c5<\/td><td>\u5185\u673a\u540a\u88c5\u3001\u5916\u673a\u5c31\u4f4d<\/td><\/tr>\n        <tr><td>\u7b2c5\u6b65<\/td><td>\u7cfb\u7edf\u8c03\u8bd5<\/td><td>\u62bd\u771f\u7a7a\u3001\u8ffd\u52a0\u51b7\u5a92\u3001\u8fd0\u884c\u6d4b\u8bd5<\/td><\/tr>\n        <tr><td>\u7b2c6\u6b65<\/td><td>\u7ae3\u5de5\u9a8c\u6536<\/td><td>\u5404\u623f\u95f4\u6e29\u5ea6\u6d4b\u8bd5\u3001\u566a\u97f3\u6d4b\u8bd5\u3001\u9a8c\u6536\u5355\u7b7e\u5b57<\/td><\/tr>\n        <tr><td>+1<\/td><td>\u4ea4\u4ed8\u6559\u5b66<\/td><td>\u9505\u7089\u64cd\u4f5c\u3001\u6e29\u63a7\u5668\u4f7f\u7528\u3001APP\u8fdc\u7a0b\u63a7\u5236\u3001\u8865\u6c34\u64cd\u4f5c<\/td><\/tr>\n        <tr><td>+2<\/td><td>\u552e\u540e\u4fdd\u969c<\/td><td>\u8d28\u4fdd\u3001\u5e74\u5ea6\u68c0\u6d4b\u3001\u7ef4\u4fdd\u63d0\u9192<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:24px;\">16.2 \u552e\u540e\u4fdd\u969c<\/h3>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u4fdd\u969c\u9879<\/th>\n          <th>\u5185\u5bb9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u8bbe\u5907\u8d28\u4fdd<\/td><td>\u65e5\u7acb\u5382\u5bb6\u8d28\u4fdd + \u9f99\u8109\u5de5\u7a0b\u8d28\u4fdd5\u5e74\u8d77<\/td><\/tr>\n        <tr><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\u9f99\u8109\u6696\u901a + \u4f1f\u661f\u5382\u5bb6 + \u4e2d\u56fd\u4eba\u4fdd<\/td><\/tr>\n        <tr><td>\u4f1a\u5458\u5ef6\u4fdd<\/td><td>\u5165\u4f1a\u540e\u5ef6\u4fdd\u81f310\u5e74<\/td><\/tr>\n        <tr><td>\u5e74\u5ea6\u68c0\u6d4b<\/td><td>\u6bcf\u5e74\u91c7\u6696\u5b63\u524d\u514d\u8d39\u4e0a\u95e8\u68c0\u6d4b<\/td><\/tr>\n        <tr><td>\u7ef4\u4fdd\u63d0\u9192<\/td><td>\u7cfb\u7edf\u81ea\u52a8\u63a8\u9001\u6e05\u6d17\u3001\u6ee4\u7f51\u66f4\u6362\u7b49\u7ef4\u62a4\u63d0\u9192<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c17\u9879\uff1a\u8054\u7cfb\u65b9\u5f0f -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"contact\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u5341\u516d\u3001\u5982\u4f55\u8054\u7cfb\u6211\u4eec<\/h2>\n  <div class=\"lm-value-grid\">\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83d\udcde<\/div>\n      <h4>\u9ec4\u52c7<\/h4>\n      <p>15828489188\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83c\udfea<\/div>\n      <h4>\u95e8\u5e97<\/h4>\n      <p>\u5317\u5bcc\u68ee\/\u5357\u5bcc\u68ee<\/p>\n    <\/div>\n    <div class=\"lm-value-card\">\n      <div class=\"lm-value-icon\">\ud83c\udf10<\/div>\n      <h4>\u5b98\u7f51<\/h4>\n      <p><blockquote class=\"wp-embedded-content\" data-secret=\"STd1TzPWr9\"><a href=\"https:\/\/longmai-nt.com\/\">\u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u6696\u6c14\u7247 | \u65e5\u7acb\u5b98\u65b9\u6388\u6743<\/a><\/blockquote><iframe loading=\"lazy\" class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; visibility: hidden;\" title=\"\u300a \u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u4e2d\u592e\u7a7a\u8c03\u5730\u6696\u6696\u6c14\u7247 | \u65e5\u7acb\u5b98\u65b9\u6388\u6743 \u300b\u2014\u9f99\u8109\u6696\u901a\" src=\"https:\/\/longmai-nt.com\/?embed=true#?secret=OO3uQIhtSI#?secret=STd1TzPWr9\" data-secret=\"STd1TzPWr9\" width=\"500\" height=\"282\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c18\u9879\uff1a\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355 -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"materials\" style=\"padding: 20px 40px 30px;background:#ffffff;\">\n  <h2>\u5341\u4e03\u3001\u5b89\u88c5\u8f85\u6750\u914d\u7f6e\u6e05\u5355<\/h2>\n  \n  <h3>\u9644\u8868A\uff1a\u4e2d\u592e\u7a7a\u8c03\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u6c1f\u7cfb\u7edf\u90e8\u5206\uff09<\/h3>\n  <p style=\"font-size:13px;color:#6b7280;margin-bottom:12px;\">\u9002\u7528\u7cfb\u7edf\uff1a\u5c0a\u777f\u5168\u6548\u2161\uff08\u5ba4\u5185\u673a\u8fde\u63a5\u90e8\u5206\uff09<\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u54c1\u724c<\/th>\n          <th>\u540d\u79f0<\/th>\n          <th>\u89c4\u683c\u578b\u53f7<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u529f\u80fd<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>6.35\/9.53\/12.7\u00d70.8mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>TP2\u9ad8\u54c1\u8d28\u94dc\u7ba1\uff0c\u51b7\u5a92\u8f93\u9001<\/td><\/tr>\n        <tr><td>\u9f99\u715c<\/td><td>\u7d2b\u94dc\u7ba1<\/td><td>15.88\/19.05\u53ca\u4ee5\u4e0a\u00d71.0mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u540c\u4e0a<\/td><\/tr>\n        <tr><td>\u9f99\u715c<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u5a92\u5206\u914d<\/td><\/tr>\n        <tr><td>\u675c\u90a6\/\u970d\u5c3c\u97e6\u5c14<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u65b0\u51b7\u5a92<\/td><\/tr>\n        <tr><td>\u5ddd\u8def<\/td><td>PVC-U\u7ba1<\/td><td>De25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51b7\u51dd\u6c34\u6392\u6c34<\/td><\/tr>\n        <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>12\u53ca\u4ee5\u4e0b\u539a\u5ea615mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\u635f\u5931<\/td><\/tr>\n        <tr><td>\u4f18\u83f2\u7279(\u65e5\u7acb\u4e13\u4f9b)<\/td><td>\u94dc\u7ba1\u4fdd\u6e29\u68c9(\u9ed8\u8ba4)<\/td><td>16\u53ca\u4ee5\u4e0a\u539a\u5ea620mm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u51cf\u5c11\u51b7\u91cf\u635f\u5931<\/td><\/tr>\n        <tr><td>\u5b9a\u5236<\/td><td>\u540a\u5361\u4e0e\u652f\u67b6<\/td><td>\u9540\u950c\u4e0d\u9508\u94a2\u540a\u67b6<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u8def\u5b89\u88c5<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <h3 style=\"margin-top:30px;\">\u9644\u8868G\uff1a\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\u7ba1\u8def\u53ca\u8f85\u6750\u6e05\u5355\uff08\u6c34\u7cfb\u7edf\u90e8\u5206\uff09<\/h3>\n  <p style=\"font-size:13px;color:#6b7280;margin-bottom:12px;\">\u9002\u7528\u7cfb\u7edf\uff1a\u5c0a\u777f\u5168\u6548+\u6c34\u6a21\u5757\uff08\u91c7\u6696\u4fa7\uff09<\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u54c1\u724c<\/th>\n          <th>\u540d\u79f0<\/th>\n          <th>\u89c4\u683c\u578b\u53f7<\/th>\n          <th>\u6570\u91cf<\/th>\n          <th>\u529f\u80fd<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u4f1f\u661f<\/td><td>F-PPRCT(\u4e3b\u7ba1)<\/td><td>dn32\u00d7en2.9\/dn40\u00d7en3.7<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u91c7\u6696\u4e3b\u7ba1<\/td><\/tr>\n        <tr><td>\u4e3d\u9a6c<\/td><td>\u6a61\u5851\u4fdd\u6e29B1(\u4e3b\u7ba1)<\/td><td>\u03c632\u00d720\/\u03c640\u00d720<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ba1\u9053\u4fdd\u6e29<\/td><\/tr>\n        <tr><td>\u4f1f\u661f<\/td><td>\u5206\u6c34\u7bb1<\/td><td>500mm<\/td><td>\u6bcf\u5c42<\/td><td>\u5b89\u88c5\u5206\u96c6\u6c34\u5668<\/td><\/tr>\n        <tr><td>\u4f1f\u661f<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>DN25<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5e73\u8861\u7cfb\u7edf\u963b\u529b<\/td><\/tr>\n        <tr><td>\u4f1f\u661f<\/td><td>PE-RT\u5730\u6696\u7ba1<\/td><td>dn20\u00d7en2.0<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><\/tr>\n        <tr><td>\u4f1f\u661f<\/td><td>\u955c\u9762\u53cd\u5c04\u819c(\u9ed8\u8ba4)<\/td><td>\u955c\u9762\u6750\u8d28<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u5411\u4e0a\u53cd\u5c04\u70ed\u91cf<\/td><\/tr>\n        <tr><td>\u8bfa\u5c14<\/td><td>\u6324\u5851\u677f(\u9ed8\u8ba4)<\/td><td>2cm<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u4fdd\u6e29\u677f<\/td><\/tr>\n        <tr><td>\u6210\u90fd\u5b9a\u5236<\/td><td>\u56de\u586b\u5c42<\/td><td>C15\u788e\u77f3\u6df7\u51dd\u571f<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u84c4\u70ed\u5c42<\/td><\/tr>\n        <tr><td>\u4f1f\u661f\/\u6c49\u5353\u5c3c\u514b<\/td><td>\u538b\u5dee\u65c1\u901a\u9600<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7ef4\u6301\u6c34\u7cfb\u7edf\u538b\u529b\u7a33\u5b9a<\/td><\/tr>\n        <tr><td>\u6c83\u8328\/\u83f2\u7d22<\/td><td>\u81ea\u52a8\u6392\u6c14\u9600<\/td><td>DN20<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u6392\u6c14<\/td><\/tr>\n        <tr><td>\u4f1f\u661f\/\u6b63\u53d1<\/td><td>Y\u578b\u8fc7\u6ee4\u5668<\/td><td>\u9002\u914d<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u8fc7\u6ee4\u6742\u8d28<\/td><\/tr>\n        <tr><td>\u9f99\u8109<\/td><td>\u8bbe\u8ba1<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u542b\u8bbe\u8ba1\/\u51fa\u56fe\/\u5b9a\u4f4d<\/td><\/tr>\n        <tr><td>\u4f1f\u661f<\/td><td>\u661f\u76d1\u7406<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>\u7b2c\u4e09\u65b9\u76d1\u7406<\/td><\/tr>\n        <tr><td>\u9f99\u8109\/\u4f1f\u661f\/\u4eba\u4fdd<\/td><td>\u4e09\u65b9\u8054\u4fdd<\/td><td>\/<\/td><td>\u5305\u5de5\u5305\u6599<\/td><td>50\u5e74\u8054\u4fdd<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  \n  <div style=\"background:#fef3c7;border:1px solid #f59e0b;border-radius:8px;padding:14px 18px;margin-top:20px;font-size:13px;line-height:1.8;color:#92400e;\">\n    <strong>\ud83d\udccc \u9644\u8868\u8bf4\u660e\u6761\u6b3e\uff1a<\/strong><br>\n    1. \u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u6750\u7b49\u6570\u91cf\u4ee5\u5b9a\u4f4d\u540e\u5b9e\u9645\u4e3a\u51c6\uff0c\u5305\u5de5\u5305\u6599\u3002<br>\n    2. \u672c\u62a5\u4ef7\u4e0d\u542b\u4e3b\u673a\u7535\u6e90\u7ebf\u548c\u7a7a\u5f00\u3002<br>\n    3. \u4e0d\u542b\u5ba4\u5916\u673a\u652f\u67b6\u548c\u63a5\u6c34\u76d8\uff0c\u4e0d\u542b\u5783\u573e\u6e05\u8fd0\u3002<br>\n    4. \u540a\u88c5\u8d39\u7528\u53e6\u8ba1\u3002<br>\n    5. \u98ce\u53e3\u6309\u673a\u8eab\u957f\u5ea6\u5b9a\u5236\uff0c\u52a0\u957f\u53e6\u8ba1\u3002<br>\n    6. \u5730\u6696\u56de\u586b\u5c42\u9700\u517b\u62a47-10\u5929\u3002<br>\n    7. \u672c\u9884\u7b97\u6709\u6548\u671f\u4e3a30\u5929\u3002\n  <\/div>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c19\u9879\uff1a\u6548\u679c\u9a8c\u8bc1\u4e0e\u5206\u6790\u8bca\u65ad -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"verify\" style=\"padding: 20px 40px 30px;background:#f9fafb;\">\n  <h2>\u5341\u516b\u3001\u6548\u679c\u9a8c\u8bc1\u4e0e\u5206\u6790\u8bca\u65ad<\/h2>\n  <p>\ud83d\udcde <strong>\u4ea4\u4ed8\u540e\uff0c\u6211\u4eec\u671f\u5f85\u60a8\u7684\u53cd\u9988\uff1a<\/strong><\/p>\n  <div class=\"lm-table-wrap\">\n    <table>\n      <thead>\n        <tr>\n          <th>\u53cd\u9988\u95ee\u9898<\/th>\n          <th>\u6211\u4eec\u7684\u884c\u52a8<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td>\u6e29\u5ea6\u662f\u5426\u5747\u5300\uff1f\u9664\u6e7f\u6548\u679c\u662f\u5426\u6ee1\u610f\uff1f\u70ed\u6c34\u662f\u5426\u5373\u5f00\u5373\u70ed\uff1f<\/td><td>\u8bb0\u5f55\u95ee\u9898\uff0c48\u5c0f\u65f6\u5185\u4e0a\u95e8\u68c0\u6d4b<\/td><\/tr>\n        <tr><td>\u8d39\u7528\u662f\u5426\u5728\u9884\u671f\u5185\uff1f<\/td><td>\u5206\u6790\u80fd\u8017\u6570\u636e\uff0c\u63d0\u4f9b\u8282\u80fd\u5efa\u8bae<\/td><\/tr>\n        <tr><td>\u6211\u4eec\u4f1a\u6839\u636e\u53cd\u9988\u6301\u7eed\u4f18\u5316\uff0c\u5e76\u8bb0\u5f55\u5728\u60a8\u7684\u4e13\u5c5e\u6863\u6848\u4e2d\u3002<\/td><td>\u66f4\u65b0\u670d\u52a1\u6863\u6848\uff0c\u5f62\u6210\u95ed\u73af<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p style=\"font-size:14px;margin-top:16px;padding:14px 18px;background:#eff6ff;border-radius:8px;border-left:4px solid #2563eb;\">\n    \ud83c\udfaf \u60a8\u5c06\u81ea\u52a8\u52a0\u5165\"<strong>10\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212<\/strong>\"B\u7ec4\uff0c\u4eab\u5168\u5957\u80fd\u6e90\u7ba1\u7406\u670d\u52a1\u3002\n  <\/p>\n<\/section>\n\n<!-- ============================== -->\n<!-- \u7b2c20\u9879\uff1a\u65b9\u6848\u4e66\u9644\u6ce8\u6761\u6b3e -->\n<!-- ============================== -->\n<section class=\"lm-section\" id=\"notes\" style=\"padding: 20px 40px 40px;background:#ffffff;\">\n  <h2>\u5341\u4e5d\u3001\u65b9\u6848\u4e66\u9644\u6ce8\u6761\u6b3e<\/h2>\n  <div style=\"background:#fef3c7;border:1px solid #f59e0b;border-radius:8px;padding:18px 22px;margin-bottom:20px;font-size:13px;line-height:1.8;color:#92400e;\">\n    <strong>\ud83d\udccc \u6e29\u99a8\u63d0\u793a\uff1a<\/strong><br>\n    1. \u672c\u65b9\u6848\u6d89\u53ca\u4e13\u4e1a\u6280\u672f\u53c2\u6570\u3002\u5982\u6709\u7591\u95ee\uff0c\u53ef\u5c06\u672c\u65b9\u6848\u53d1\u7ed9AI\u52a9\u624b\uff08DeepSeek\u3001\u8c46\u5305\uff09\u8fdb\u884c\u5bf9\u6bd4\u5206\u6790\u3002<br>\n    2. <strong>\u26a0\ufe0f \u70ed\u6c34\u5faa\u73af\u6ce8\u610f\u4e8b\u9879\uff1a<\/strong>\u672c\u65b9\u6848\u96f6\u51b7\u6c34\u529f\u80fd\u9700\u8981\u5728\u6c34\u7535\u6539\u9020\u9636\u6bb5\u9884\u57cb\u56de\u6c34\u7ba1\u3002\u8bf7\u52a1\u5fc5\u5728\u88c5\u4fee\u6c34\u7535\u8fdb\u573a\u524d\u544a\u77e5\u8bbe\u8ba1\u5e08\u548c\u6c34\u7535\u5de5\uff0c\u9884\u7559\u56de\u6c34\u7ba1\u8def\u3002<strong>\u5982\u672a\u9884\u7559\uff0c\u540e\u671f\u65e0\u6cd5\u5b9e\u73b0\u5373\u5f00\u5373\u70ed\u3002<\/strong><br>\n    3. \u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a30\u5929\uff08\u81f32026\u5e744\u670817\u65e5\uff09\uff0c\u903e\u671f\u9700\u91cd\u65b0\u786e\u8ba4\u4ef7\u683c\u3002\n  <\/div>\n  \n  <div style=\"border-top:2px solid #e5e7eb;padding-top:20px;margin-top:20px;\">\n    <p style=\"margin:0 0 8px 0;font-size:14px;\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/p>\n    <div class=\"lm-table-wrap\" style=\"margin-top:16px;\">\n      <table>\n        <tbody>\n          <tr><td style=\"width:120px;\"><strong>\u5ba2\u6237\u786e\u8ba4\u7b7e\u5b57<\/strong><\/td><td>_________________  \u65e5\u671f\uff1a_________<\/td><\/tr>\n          <tr><td><strong>\u9f99\u8109\u6696\u901a\u76d6\u7ae0<\/strong><\/td><td>_________________  \u65e5\u671f\uff1a_________<\/td><\/tr>\n          <tr><td><strong>\u65b9\u6848\u5236\u5b9a<\/strong><\/td><td>\u9ec4\u52c7<\/td><\/tr>\n          <tr><td><strong>\u5ba1\u6838<\/strong><\/td><td>\u7f2a\u8001\u5e08<\/td><\/tr>\n          <tr><td><strong>\u65e5\u671f<\/strong><\/td><td>2026\u5e743\u670818\u65e5<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n  <\/div>\n<\/section>\n\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u7b2c\u4e8c\u9636\u6bb5\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1\u7b7e\u7ea6\u540e\u4ea4\u4ed8<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-2\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<h4 class=\"wp-block-heading\">\u4e00\u3001\u9879\u76ee\u6982\u8ff0\u4e0e\u8bbe\u8ba1\u4f9d\u636e<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8bbe\u8ba1\u4f9d\u636e\uff1a<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">   \u5176\u4ed6\u76f8\u5173\u56fd\u5bb6\u53ca\u884c\u4e1a\u6807\u51c6<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u300a\u6c11\u7528\u5efa\u7b51\u4f9b\u6696\u901a\u98ce\u4e0e\u7a7a\u6c14\u8c03\u8282\u8bbe\u8ba1\u89c4\u8303\u300bGB50736-2012<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u300a\u8f90\u5c04\u4f9b\u6696\u4f9b\u51b7\u6280\u672f\u89c4\u7a0b\u300bJGJ 142-2012<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5173\u952e\u53c2\u6570\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">\u53c2\u6570\u9879<\/th><th class=\"has-text-align-center\" data-align=\"center\">           \u6807\u51c6\u503c              <\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">\u590f\u5b63\u5ba4\u6e29<\/td><td class=\"has-text-align-center\" data-align=\"center\">24-26\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u51ac\u5b63\u5ba4\u6e29<\/td><td class=\"has-text-align-center\" data-align=\"center\">18-22\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u5730\u6696\u4f9b\u6c34\u6e29\u5ea6<\/td><td class=\"has-text-align-center\" data-align=\"center\">35-45\u2103<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u5408\u540c\u7b7e\u5b9a<\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"606\" height=\"808\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg\" alt=\"\" class=\"wp-image-3880\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg 606w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1-225x300.jpg 225w\" sizes=\"(max-width: 606px) 100vw, 606px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"282\" height=\"376\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht3.jpg\" alt=\"\" class=\"wp-image-3881\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht3.jpg 282w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht3-225x300.jpg 225w\" sizes=\"(max-width: 282px) 100vw, 282px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"555\" height=\"740\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht2.jpg\" alt=\"\" class=\"wp-image-3883\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht2.jpg 555w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht2-225x300.jpg 225w\" sizes=\"(max-width: 555px) 100vw, 555px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e8c\u3001\u914d\u7f6e\u6750\u6599\u6e05\u5355<\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"568\" height=\"426\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd1.jpg\" alt=\"\" class=\"wp-image-3884\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd1.jpg 568w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd1-300x225.jpg 300w\" sizes=\"(max-width: 568px) 100vw, 568px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"552\" height=\"414\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd2.jpg\" alt=\"\" class=\"wp-image-3885\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd2.jpg 552w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd2-300x225.jpg 300w\" sizes=\"(max-width: 552px) 100vw, 552px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"552\" height=\"414\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd3.jpg\" alt=\"\" class=\"wp-image-3886\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd3.jpg 552w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd3-300x225.jpg 300w\" sizes=\"(max-width: 552px) 100vw, 552px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"560\" height=\"420\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd4.jpg\" alt=\"\" class=\"wp-image-3887\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd4.jpg 560w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd4-300x225.jpg 300w\" sizes=\"(max-width: 560px) 100vw, 560px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"480\" height=\"360\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd5.jpg\" alt=\"\" class=\"wp-image-3888\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd5.jpg 480w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd5-300x225.jpg 300w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"452\" height=\"339\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd6.jpg\" alt=\"\" class=\"wp-image-3889\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd6.jpg 452w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd6-300x225.jpg 300w\" sizes=\"(max-width: 452px) 100vw, 452px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"555\" height=\"740\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd7.jpg\" alt=\"\" class=\"wp-image-3890\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd7.jpg 555w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd7-225x300.jpg 225w\" sizes=\"(max-width: 555px) 100vw, 555px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"554\" height=\"416\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd8.jpg\" alt=\"\" class=\"wp-image-3891\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd8.jpg 554w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd8-300x225.jpg 300w\" sizes=\"(max-width: 554px) 100vw, 554px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"546\" height=\"410\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd9.jpg\" alt=\"\" class=\"wp-image-3892\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd9.jpg 546w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd9-300x225.jpg 300w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"360\" height=\"270\" fetchpriority=\"low\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd10.jpg\" alt=\"\" class=\"wp-image-3893\" srcset=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd10.jpg 360w, https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-qd10-300x225.jpg 300w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">\u4e09\u3001\u65bd\u5de5\u6d41\u7a0b\uff1a\u7cbe\u5de5\u516d\u6b65\u6cd5+2<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\uff08\u6b64\u90e8\u5206\u5c06\u5728\u65bd\u5de5\u8fc7\u7a0b\u4e2d\u9010\u9879\u5b8c\u6210\uff0c\u5e76\u9644\u73b0\u573a\u7167\u7247\u5b58\u6863\uff09<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6b65\u9aa4<\/th><th>\u5185\u5bb9<\/th><th>\u72b6\u6001<\/th><\/tr><\/thead><tbody><tr><td><strong>\u73b0\u573a\u52d8\u6d4b<\/strong><\/td><td>\u786e\u8ba4\u5916\u673a\u4f4d\u3001\u65b0\u98ce\u7ba1\u8def\u3001\u5730\u6696\u5206\u6c34\u5668\u4f4d\u7f6e\u7b49\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>\u8bbe\u8ba1\u51fa\u56fe<\/strong><\/td><td>\u51fa\u5177\u5185\u673a\u5b9a\u4f4d\u56fe\u3001\u5730\u6696\u76d8\u7ba1\u56fe\u3001\u65b0\u98ce\u5e03\u7ba1\u56fe\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>\u9690\u853d\u5de5\u7a0b<\/strong><\/td><td>\u6267\u884c\u6c2e\u6c14\u4fdd\u62a4\u710a\u3001\u4fdd\u538b\u6d4b\u8bd5\uff084.0MPa\uff0c48\u5c0f\u65f6\uff09\u3001\u6392\u6c34\u7ba1\u5761\u5ea6\u22651%\u7b49\u6807\u51c6\u5de5\u827a\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>\u76d1\u7406\u5230\u4f4d<\/strong><\/td><td>\u516c\u53f8\u76d1\u7406\u5de1\u68c0\uff0c\u5173\u952e\u8282\u70b9\u62cd\u7167\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>\u7cfb\u7edf\u8c03\u8bd5<\/strong><\/td><td>\u5355\u673a\u6d4b\u8bd5\u3001\u7cfb\u7edf\u8054\u52a8\u3001\u4e94\u7ef4\u6307\u6807\uff08\u6e29\/\u6e7f\/CO\u2082\/PM2.5\/\u566a\u97f3\uff09\u68c0\u6d4b\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>\u7ae3\u5de5\u9a8c\u6536<\/strong><\/td><td>\u586b\u5199\u9a8c\u6536\u5355\uff0c\u5ba2\u6237\u7b7e\u5b57\u786e\u8ba4\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>+1 \u4ea4\u4ed8\u6559\u5b66<\/strong><\/td><td>\u63d0\u4f9b\u64cd\u4f5c\u901f\u67e5\u8868\uff0c\u73b0\u573a\u57f9\u8bad\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><tr><td><strong>+2 \u552e\u540e\u4fdd\u969c<\/strong><\/td><td>\u5efa\u7acb\u6863\u6848\uff0c\u52a0\u5165\u4f1a\u5458\u53ca\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\u3002<\/td><td>\u5f85\u65bd\u5de5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\u56db\u3001\u8c03\u8bd5\u9a8c\u6536\u5355<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u9a8c\u6536\u65e5\u671f<\/td><td>____\u5e74 ___\u6708 ___\u65e5<\/td><\/tr><tr><td>\u9a8c\u6536\u4eba\u5458<\/td><td>\u5218\u5973\u58eb\u3001\u9ec4\u52c7\u987e\u95ee\u3001\u65bd\u5de5\u8d1f\u8d23\u4eba<\/td><\/tr><tr><td>\u9a8c\u6536\u5185\u5bb9<\/td><td>\u25a1 \u5168\u7cfb\u7edf\u8054\u52a8\u8fd0\u884c&lt;br&gt;\u25a1 \u5404\u623f\u95f4\u7a7a\u8c03\u9001\u98ce\u6e29\u5ea6\u5b9e\u6d4b&lt;br&gt;\u25a1 \u5730\u6696\u5206\u533a\u5347\u6e29\u6d4b\u8bd5&lt;br&gt;\u25a1 \u65b0\u98ce\u98ce\u91cf\u4e0e\u566a\u97f3\u6d4b\u8bd5&lt;br&gt;\u25a1 \u70ed\u6c34\u5668\u6052\u6e29\u53ca\u5faa\u73af\u6548\u679c\u6d4b\u8bd5&lt;br&gt;\u25a1 APP\u8fdc\u7a0b\u63a7\u5236\u6f14\u793a<\/td><\/tr><tr><td>\u9a8c\u6536\u7ed3\u8bba<\/td><td>\u25a1 \u901a\u8fc7 \u2003 \u25a1 \u9700\u6574\u6539\uff08____________\uff09<\/td><\/tr><tr><td>\u5ba2\u6237\u7b7e\u5b57<\/td><td><\/td><\/tr><tr><td>\u9a8c\u6536\u7167\u7247<\/td><td>\uff08\u89c1\u4e0b\u65b9\u9644\u56fe\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e94\u3001\u4ea4\u4ed8\u6559\u5b66\uff1a\u7cfb\u7edf\u64cd\u4f5c\u901f\u67e5\u8868<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\uff08\u4ea4\u4ed8\u65f6\u5c06\u63d0\u4f9b\u5b8c\u6574\u7eb8\u8d28\u7248\u548c\u7535\u5b50\u7248\uff0c\u6db5\u76d6\uff1a\uff09<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u7cfb\u7edf<\/th><th>\u64cd\u4f5c\u8981\u70b9<\/th><\/tr><\/thead><tbody><tr><td><strong>\u4e2d\u592e\u7a7a\u8c03<\/strong><\/td><td>\u6a21\u5f0f\u8bbe\u5b9a\u3001\u98ce\u901f\u5efa\u8bae\u3001\u6ee4\u7f51\u6e05\u6d17\uff08\u6bcf\u6708\uff09\u3001\u81ea\u6e05\u6d01\u542f\u52a8<\/td><\/tr><tr><td><strong>\u5730\u6696<\/strong><\/td><td>\u9505\u7089\u6c34\u6e29\u8bbe\u5b9a\uff0835-45\u2103\uff09\u3001\u5ba4\u6e29\u8bbe\u5b9a\uff0818-22\u2103\uff09\u3001\u9996\u6b21\u5347\u6e29\u6b65\u9aa4\u3001\u6392\u6c14\u8865\u6c34\u64cd\u4f5c<\/td><\/tr><tr><td><strong>\u65b0\u98ce<\/strong><\/td><td>\u8fd0\u884c\u6a21\u5f0f\u5207\u6362\u3001\u6ee4\u7f51\u66f4\u6362\u5468\u671f\uff083-6\u4e2a\u6708\uff09\u3001\u4e94\u7ef4\u6570\u636e\u67e5\u770b<\/td><\/tr><tr><td><strong>\u70ed\u6c34\u5668<\/strong><\/td><td>\u96f6\u51b7\u6c34\u6a21\u5f0f\u8bbe\u5b9a\u3001\u65e5\u5e38\u4f7f\u7528\u6ce8\u610f\u4e8b\u9879<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-3&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-3-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" id=\"accordion-item-3\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u7b2c\u4e09\u9636\u6bb5\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3\uff08\u552e\u540e\u5341\u5e74\uff09<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div aria-labelledby=\"accordion-item-3\" data-wp-bind--hidden=\"state.isHidden\" data-wp-on--beforematch=\"actions.handleBeforeMatch\" id=\"accordion-item-3-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<h3 class=\"wp-block-heading\">\u4e00\u3001\u80fd\u8017\u8ddf\u8e2a\u4e0e\u89e3\u6790\uff0810\u5e74\u80fd\u6e90\u4fdd\u969c\u8ba1\u5212\uff09<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">1.1 \u6570\u636e\u57fa\u51c6\uff08\u8c03\u8bd5\u5f53\u65e5\u8bb0\u5f55\uff09<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u9879\u76ee<\/th><th>\u57fa\u51c6\u6570\u636e<\/th><\/tr><\/thead><tbody><tr><td>\u8c03\u8bd5\u65e5\u671f<\/td><td>____\u5e74 ___\u6708 ___\u65e5<\/td><\/tr><tr><td>\u5730\u6696\u4f9b\u6c34\/\u56de\u6c34\u6e29\u5ea6<\/td><td>___\u2103 \/ ___\u2103<\/td><\/tr><tr><td>\u5ba4\u5185\u8bbe\u5b9a\u6e29\u5ea6<\/td><td>20\u2103<\/td><\/tr><tr><td>\u5ba4\u5916\u6e29\u5ea6<\/td><td>___\u2103<\/td><\/tr><tr><td>\u71c3\u6c14\u8868\u521d\u59cb\u8bfb\u6570<\/td><td>___ m\u00b3<\/td><\/tr><tr><td>\u91c7\u6696\u9762\u79ef<\/td><td>201\u33a1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">1.2 \u5e74\u5ea6\u80fd\u8017\u8ddf\u8e2a\u8bb0\u5f55\u8868<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u5e74\u5ea6<\/th><th>\u91c7\u6696\u5b63(\u6708)<\/th><th>\u8017\u7535\u91cf(m\u00b3)<\/th><th>\u603b\u8d39\u7528(\u5143)<\/th><th>\u6708\u5747\u8d39\u7528(\u5143)<\/th><th>\u5355\u4f4d\u8d39\u7528(\u5143\/\u33a1\u00b7\u6708)<\/th><th>\u4e1a\u4e3b\u53cd\u9988<\/th><\/tr><\/thead><tbody><tr><td>\u7b2c1\u5e74<\/td><td>2026\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c2\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c3\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c4\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c5\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c6\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c7\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c8\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c9\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>\u7b2c10\u5e74<\/td><td>2035\u5e74<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u80fd\u8017\u53c2\u8003\u57fa\u51c6\uff1a<\/strong>&nbsp;\u540c\u6237\u578b201\u33a1\uff0c\u5929\u6c1f\u5730\u6c34\u4e24\u8054\u4f9b\uff0c\u5ba4\u6e2920\u2103\uff0c\u6210\u90fd\u5730\u533a\uff0c\u5730\u6696\u5b63\u53c2\u8003\u603b\u8d39\u7528\u7ea6&nbsp;<strong>3,000-4,000\u5143<\/strong>\uff08\u7406\u8bba\u8ba1\u7b97\uff09\u3002<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e8c\u3001\u552e\u540e\u670d\u52a1\u8bb0\u5f55<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u65e5\u671f<\/th><th>\u670d\u52a1\u7c7b\u578b<\/th><th>\u670d\u52a1\u5185\u5bb9<\/th><th>\u670d\u52a1\u4eba\u5458<\/th><th>\u5ba2\u6237\u786e\u8ba4<\/th><\/tr><\/thead><tbody><tr><td>____\u5e74__\u6708__\u65e5<\/td><td>\u56de\u8bbf<\/td><td><\/td><td>\u9ec4\u52c7<\/td><td><\/td><\/tr><tr><td>____\u5e74__\u6708__\u65e5<\/td><td>\u5e74\u5ea6\u4fdd\u517b<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<\/strong><\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">\u8700ICP\u5907<\/pre>\n","protected":false},"excerpt":{"rendered":"<p>\u6863\u6848\u7f16\u53f7\uff1aB-B hdsscls001  [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2168","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2168\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6863\u6848\u7f16\u53f7\uff1aB-B hdsscls001 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2168\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-19T07:40:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"606\" \/>\n\t<meta property=\"og:image:height\" content=\"808\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168\",\"name\":\"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/hdssc-ls-dns-ht1.jpg\",\"datePublished\":\"2026-06-06T13:59:27+00:00\",\"dateModified\":\"2026-06-19T07:40:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/hdssc-ls-dns-ht1.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/hdssc-ls-dns-ht1.jpg\",\"width\":606,\"height\":808},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2168#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2168","og_locale":"zh_CN","og_type":"article","og_title":"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848 - \u9f99\u8109\u6696\u901a","og_description":"\u6863\u6848\u7f16\u53f7\uff1aB-B hdsscls001 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2168","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-19T07:40:13+00:00","og_image":[{"width":606,"height":808,"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"9 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2168","url":"https:\/\/longmai-nt.com\/?page_id=2168","name":"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=2168#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=2168#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg","datePublished":"2026-06-06T13:59:27+00:00","dateModified":"2026-06-19T07:40:13+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2168#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2168"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=2168#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/hdssc-ls-dns-ht1.jpg","width":606,"height":808},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2168#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u6052\u5927\u5c71\u6c34\u57ce-\u5218\u5973\u58eb\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u8054\u4f9b\u7cfb\u7edf\u6863\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2168","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2168"}],"version-history":[{"count":11,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2168\/revisions"}],"predecessor-version":[{"id":3900,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2168\/revisions\/3900"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2168"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}