{"id":2176,"date":"2026-06-05T18:21:05","date_gmt":"2026-06-05T10:21:05","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2176"},"modified":"2026-06-06T15:26:57","modified_gmt":"2026-06-06T07:26:57","slug":"%e4%ba%91%e7%92%9f%e6%9e%97%e8%91%97x%e5%85%88%e7%94%9f%e7%a9%ba%e8%b0%83%e6%96%b0%e9%a3%8e%e6%a1%a3%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2176","title":{"rendered":"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66"},"content":{"rendered":"\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">\u76ee\u5f55<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div inert aria-labelledby=\"accordion-item-1\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs01\">\u7b2c\u4e00\u7ae0\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1\uff08\u65b9\u6848\u524d\u4e66\uff09<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0101\">\u7b2c\u4e00\u8282\uff1a\u5ba2\u6237\u57fa\u7840\u4fe1\u606f<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0102\">\u7b2c\u4e8c\u8282\uff1a\u9700\u6c42\u7406\u89e3<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0103\">\u7b2c\u4e09\u8282\uff1a\u53cc\u65b9\u6848\u5bf9\u6bd4<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs010301\">\uff08\u4e00\uff09\u914d\u7f6e\u6e05\u5355<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs010302\">\uff08\u4e8c\uff09\u6838\u5fc3\u53c2\u6570<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs010302\">\uff08\u4e09\uff09\u8bbe\u8ba1\u4f9d\u636e<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0105\">\u7b2c\u56db\u8282\uff1a\u65b0\u98ce\u7cfb\u7edf<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs010501\">\uff08\u4e00\uff09\u6838\u5fc3\u53c2\u6570<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0106\">\u7b2c\u4e94\u8282\uff1a\u4f1a\u5458\u6743\u76ca<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0109\">\u7b2c\u516d\u8282\uff1a\u670d\u52a1\u627f\u8bfa<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02\">\u7b2c\u4e8c\u7ae0\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0201\">\u7b2c\u4e00\u8282\uff1a\u6982\u8ff0<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020101\">\uff08\u4e00\uff09\u9879\u76ee\u4fe1\u606f\uff08\u914d\u7f6e\u6750\u6599\u6e05\u5355\uff09<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02010101\">\u4e2d\u592e\u7a7a\u8c03\u90e8\u5206<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02010103\">\u65b0\u98ce\u7cfb\u7edf<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020102\">\uff08\u4e8c\uff09\u8bbe\u8ba1\u4f9d\u636e<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02010201\">\u5f15\u7528\u6807\u51c6\u4e0e\u89c4\u8303<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02010202\">\u7a7a\u8c03\u8bbe\u8ba1\u53c2\u6570<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02010203\">\u5730\u6696\u8bbe\u8ba1\u53c2\u6570<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020103\">\uff08\u4e09\uff09\u5907\u6ce8\u8bf4\u660e<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0202\">\u7b2c\u4e8c\u8282\uff1a\u65bd\u5de5\u6d41\u7a0b\u2014\u2014\u7cbe\u5de56\u6b65\u6cd5+2<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020201\">\uff08\u4e00\uff09\u7b2c\u4e00\u6b65\uff1a\u73b0\u573a\u52d8\u6d4b<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020202\">\uff08\u4e8c\uff09\u7b2c\u4e8c\u6b65\uff1a\u8bbe\u8ba1\u51fa\u56fe<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020203\">\uff08\u4e09\uff09\u7b2c\u4e09\u6b65\uff1a\u9690\u853d\u5de5\u7a0b\u7cbe\u5de56\u6b65\u6cd5<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020204\">\uff08\u56db\uff09\u7b2c\u56db\u6b65\uff1a\u76d1\u7406\u5230\u4f4d<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020205\">\uff08\u4e94\uff09\u7b2c\u4e94\u6b65\uff1a\u7cfb\u7edf\u8c03\u8bd5<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020206\">\uff08\u516d\uff09\u7b2c\u516d\u6b65\uff1a\u7ae3\u5de5\u9a8c\u6536<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020207\">\uff08\u4e03\uff09+1\uff1a\u4ea4\u4ed8\u6559\u5b66\uff08\u64cd\u4f5c\u8981\u70b9\u901f\u67e5\uff09<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02020701\">\u4e2d\u592e\u7a7a\u8c03\u90e8\u5206<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02020703\">\u65b0\u98ce\u7cfb\u7edf<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02020704\">\u901a\u7528\u7ef4\u62a4\u63d0\u9192<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02020705\">\u7d27\u6025\u60c5\u51b5\u5904\u7406<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs020208\">\uff08\u516b\uff09+2\uff1a\u552e\u540e\u4fdd\u969c<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs03\">\u7b2c\u4e09\u7ae0\uff1a\u6301\u7eed\u8ddf\u8fdb\u4e0e\u4f18\u5316\u8fed\u4ee3<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0301\">\u7b2c\u4e00\u8282\uff1a\u5ba2\u6237\u53cd\u9988<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0302\">\u7b2c\u4e8c\u8282\uff1a\u80fd\u8017\u8ddf\u8e2a\u4e0e\u89e3\u6790<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs030201\">\uff08\u4e00\uff09\u80fd\u8017\u8ddf\u8e2a\u670d\u52a1\u627f\u8bfa<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs030202\">\uff08\u4e8c\uff09\u6570\u636e\u57fa\u51c6<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs030203\">\u5e74\u5ea6\u8ddf\u8e2a\u8bb0\u5f55\u8868<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs030204\">\u80fd\u8017\u5bf9\u6807\u57fa\u51c6<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs03020401\">\u7cfb\u7edf\u6761\u4ef6<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs03020402\">\u4f7f\u7528\u6761\u4ef6<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs03020403\">\u5efa\u7b51\u6761\u4ef6<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs03020404\">\u8d39\u7528\u6761\u4ef6<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs030205\">\u7406\u8bba\u8ba1\u7b97\u503c<\/a><\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs030206\">\u504f\u5dee\u8bf4\u660e<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs0303\">\u7b2c\u4e09\u8282\uff1a\u552e\u540e\u670d\u52a1\u8bb0\u5f55\u4e0e\u89e3\u6790<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\"><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs01\">\u7b2c\u4e00\u7ae0\uff1a\u8bca\u65ad\u5206\u6790\u4e0e\u65b9\u6848\u8bbe\u8ba1\uff08\u65b9\u6848\u524d\u4e66\uff09<\/a><\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div inert aria-labelledby=\"accordion-item-2\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n\n<div style=\",sans-serif;background:#f3f4f6;color:#2c2c2c;line-height:1.75;font-size:15px;margin:0;padding:0\">\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 COVER \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"background:linear-gradient(160deg,#0d1f3c 0%,#1a3a6e 40%,#1e4d8c 100%);color:#fff;text-align:center;padding:80px 24px 64px;position:relative;overflow:hidden\">\n<div style=\"position:absolute;top:-100px;right:-120px;width:400px;height:400px;border-radius:50%\"><\/div>\n<div style=\"position:absolute;bottom:-80px;left:-80px;width:300px;height:300px;border-radius:50%\"><\/div>\n<div style=\"font-size:13px;letter-spacing:6px;opacity:0.6;margin-bottom:12px;position:relative\">\u9f99 \u8109 \u6696 \u901a<\/div>\n<h1 style=\"font-size:34px;font-weight:800;position:relative;margin-bottom:8px;color:#fff\">\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u524d\u4e66<\/h1>\n<div style=\"font-size:15px;opacity:0.6;font-weight:300;position:relative\">\u4ee5\u79d1\u5b66\u8bbe\u8ba1\u5339\u914d\u771f\u5b9e\u751f\u6d3b<\/div>\n<div style=\"width:60px;height:3px;background:#c8963e;margin:24px auto 0;border-radius:2px\"><\/div>\n<div style=\"display:flex;justify-content:center;gap:32px;flex-wrap:wrap;margin-top:36px;position:relative\">\n<div style=\"text-align:center\"><div style=\"font-size:11px;opacity:0.55;letter-spacing:2px;text-transform:uppercase\">\u5ba2\u6237<\/div><div style=\"font-size:18px;font-weight:600;margin-top:2px\">\u5f90\u5148\u751f<\/div><\/div>\n<div style=\"text-align:center\"><div style=\"font-size:11px;opacity:0.55;letter-spacing:2px;text-transform:uppercase\">\u9879\u76ee\u5730\u5740<\/div><div style=\"font-size:18px;font-weight:600;margin-top:2px\">\u53cc\u6d41 \u00b7 \u6021\u5fc3\u6e56<\/div><\/div>\n<div style=\"text-align:center\"><div style=\"font-size:11px;opacity:0.55;letter-spacing:2px;text-transform:uppercase\">\u65b9\u6848\u65e5\u671f<\/div><div style=\"font-size:18px;font-weight:600;margin-top:2px\">2026\u5e744\u670817\u65e5<\/div><\/div>\n<div style=\"text-align:center\"><div style=\"font-size:11px;opacity:0.55;letter-spacing:2px;text-transform:uppercase\">\u4ea7\u54c1\u7cfb\u5217<\/div><div style=\"font-size:18px;font-weight:600;margin-top:2px\">\u65e5\u7acb EX-\u8212\u4eab180<\/div><\/div>\n<\/div>\n<\/div>\n\n<div style=\"max-width:920px;margin:0 auto;padding:0 20px 60px\">\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e00\u3001\u5ba2\u6237\u4fe1\u606f\u5361 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u4e00<\/span>\u5ba2\u6237\u4fe1\u606f\u5361\n<\/div>\n\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(180px,1fr));gap:12px\">\n<div style=\"background:#f8f9fb;border-radius:8px;padding:14px 16px;text-align:center;border:1px solid #e2e6ed\"><div style=\"font-size:11px;color:#999;margin-bottom:4px;letter-spacing:1px\">\u5ba2\u6237\u79f0\u547c<\/div><div style=\"font-size:17px;font-weight:700;color:#1a3a6e\">\u5f90\u5148\u751f<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:14px 16px;text-align:center;border:1px solid #e2e6ed\"><div style=\"font-size:11px;color:#999;margin-bottom:4px;letter-spacing:1px\">\u6237\u578b\u6982\u51b5<\/div><div style=\"font-size:17px;font-weight:700;color:#1a3a6e\">\u56db\u5ba4\u4e24\u5385<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:14px 16px;text-align:center;border:1px solid #e2e6ed\"><div style=\"font-size:11px;color:#999;margin-bottom:4px;letter-spacing:1px\">\u7a7a\u8c03\u9762\u79ef<\/div><div style=\"font-size:17px;font-weight:700;color:#1a3a6e\">\u7ea6 99 m\u00b2<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:14px 16px;text-align:center;border:1px solid #e2e6ed\"><div style=\"font-size:11px;color:#999;margin-bottom:4px;letter-spacing:1px\">\u5e38\u4f4f\u4eba\u53e3<\/div><div style=\"font-size:17px;font-weight:700;color:#1a3a6e\">4 \uff5e 5 \u4eba<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:14px 16px;text-align:center;border:1px solid #e2e6ed\"><div style=\"font-size:11px;color:#999;margin-bottom:4px;letter-spacing:1px\">\u9501\u5b9a\u5916\u673a<\/div><div style=\"font-size:17px;font-weight:700;color:#c8963e\">\u8212\u4eab180<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:14px 16px;text-align:center;border:1px solid #e2e6ed\"><div style=\"font-size:11px;color:#999;margin-bottom:4px;letter-spacing:1px\">\u4ea7\u54c1\u7cfb\u5217<\/div><div style=\"font-size:17px;font-weight:700;color:#1a3a6e\">\u65e5\u7acb EX-\u8212\u4eab<\/div><\/div>\n<\/div>\n\n<div style=\"background:#f8f9fb;border-radius:12px;box-shadow:none;border:1px solid #e2e6ed;padding:28px 32px;margin-bottom:20px;margin-top:14px\">\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap;border-radius:6px 0 0 0\">\u533a\u57df<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u9762\u79ef<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u529f\u80fd<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap;border-radius:0 6px 0 0\">\u4f7f\u7528\u7279\u70b9<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u5ba2\u9910\u5385<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">49 m\u00b2<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u65e5\u5e38\u6d3b\u52a8\u4e2d\u5fc3<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u767d\u5929\u9ad8\u9891\u4f7f\u7528\uff0c\u7a7a\u8c03\u8986\u76d6\u9762\u79ef\u6700\u5927<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u4e3b\u5367<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">17 m\u00b2<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u4e3b\u4eba\u5367\u5ba4<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u591c\u95f4\u4f7f\u7528\uff0c\u9700\u5b89\u9759\u8212\u9002<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u6b21\u5367 A<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11 m\u00b2<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u5367\u5ba4<\/td><td rowspan=\"3\" style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u591c\u95f4\u4f7f\u7528\uff0c\u4e09\u95f4\u5367\u5ba4\u89c4\u683c\u4e00\u81f4<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u6b21\u5367 B<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11 m\u00b2<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u5367\u5ba4<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u6b21\u5367 C<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11 m\u00b2<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u5367\u5ba4<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin:16px 0;background:#e8f0fe;border-left:4px solid #1a3a6e;color:#1a3a6e\">\n<strong>\ud83d\udcd0 \u8bbe\u8ba1\u5224\u65ad\uff1a<\/strong>\u56db\u5ba4\u4e24\u5385\u51715\u4e2a\u7a7a\u8c03\u533a\u57df\uff0c\u5916\u673a\u8212\u4eab180\uff0818.0kW\uff09\u5339\u914d4-5\u4eba\u5bb6\u5ead\u7ef0\u7ef0\u6709\u4f59\u3002\u6838\u5fc3\u60ac\u5ff5\u5728\u4e8e\u5ba2\u9910\u538549m\u00b2\u2014\u2014\u662f&#8221;\u4e00\u53f0\u5927\u5185\u673a\u8986\u76d6&#8221;\u8fd8\u662f&#8221;\u4e24\u53f0\u5185\u673a\u5206\u533a\u9001\u98ce&#8221;\uff0c\u8fd9\u76f4\u63a5\u5f71\u54cd\u6c14\u6d41\u5747\u5300\u5ea6\u548c\u65e5\u540e\u4f7f\u7528\u4f53\u9a8c\u3002\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e8c\u3001\u9700\u6c42\u4e0e\u75db\u70b9\u5206\u6790 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u4e8c<\/span>\u9700\u6c42\u4e0e\u75db\u70b9\u8bca\u65ad\n<\/div>\n\n<div style=\"display:flex;gap:16px;padding:20px 24px;background:#fff;border-radius:10px;margin-bottom:14px;border:1px solid #e2e6ed;align-items:flex-start\">\n<div style=\"width:44px;height:44px;border-radius:10px;flex-shrink:0;display:flex;align-items:center;justify-content:center;font-size:22px;background:#fde8e8\">\ud83e\udec1<\/div>\n<div style=\"flex:1\">\n<div style=\"font-weight:700;font-size:15px;color:#1a3a6e;margin-bottom:4px\">\u75db\u70b9\u4e00\uff1a\u5c0f\u670b\u53cb\u9f3b\u708e\uff0c\u7a7a\u6c14\u51c0\u5316\u8981\u6c42\u9ad8<\/div>\n<div style=\"font-size:13px;color:#5a5a5a;margin-bottom:8px\">\u5bb6\u91cc\u5c0f\u670b\u53cb\u6709\u8fc7\u654f\u6027\u9f3b\u708e\uff0c\u5bf9\u7a7a\u6c14\u4e2d\u7070\u5c18\u3001\u7ec6\u83cc\u3001\u9709\u83cc\u9ad8\u5ea6\u654f\u611f\uff0c\u7a7a\u8c03\u51fa\u98ce\u7a0d\u6709\u5f02\u5473\u5c31\u53ef\u80fd\u8bf1\u53d1\u75c7\u72b6\u3002<\/div>\n<div style=\"font-size:13px;color:#27ae60;line-height:1.8\">\n\u2705 <strong>\u5185\u673a\u81ea\u6e05\u6d01 + \u9ad8\u6e29\u6740\u83cc\uff1a<\/strong>\u84b8\u53d1\u5668\u81ea\u52a8\u7ed3\u51b0-\u5316\u971c-\u70d8\u5e72\u4e09\u6b65\u6e05\u6d01\uff0c56\u2103\u9ad8\u6e29\u6740\u83cc30\u5206\u949f\uff0c\u4ece\u6839\u6e90\u675c\u7edd\u7ec6\u83cc\u9709\u83cc\u6ecb\u751f<br>\n\u2705 <strong>PE\u51c0\u5316\u6a21\u5757\uff08\u9009\u914d\uff09\uff1a<\/strong>\u91ca\u653e\u8d1f\u79bb\u5b50\uff0c\u4e3b\u52a8\u5206\u89e3PM2.5\u3001\u7532\u919b\u3001\u7ec6\u83cc\uff0c\u6d01\u51c0\u7a7a\u6c14\u5439\u5165\u623f\u95f4\uff0c\u53bb\u9664\u7387\u226599%<br>\n\u2705 <strong>\u8212\u4eab\u5168\u7cfb\u6807\u914d\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173\uff1a<\/strong>\u675c\u7edd\u79ef\u6c34\u76d8\u957f\u83cc\u3001\u9632\u6ce1\u9876\u6f0f\u6c34\uff0c\u5bf9\u8fc7\u654f\u4f53\u8d28\u66f4\u53cb\u597d\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"display:flex;gap:16px;padding:20px 24px;background:#fff;border-radius:10px;margin-bottom:14px;border:1px solid #e2e6ed;align-items:flex-start\">\n<div style=\"width:44px;height:44px;border-radius:10px;flex-shrink:0;display:flex;align-items:center;justify-content:center;font-size:22px;background:#e8f0fe\">\u23f3<\/div>\n<div style=\"flex:1\">\n<div style=\"font-weight:700;font-size:15px;color:#1a3a6e;margin-bottom:4px\">\u75db\u70b9\u4e8c\uff1a\u62c5\u5fc3\u4e2d\u592e\u7a7a\u8c03\u4f7f\u7528\u5bff\u547d\u548c\u53ef\u9760\u6027<\/div>\n<div style=\"font-size:13px;color:#5a5a5a;margin-bottom:8px\">\u4e2d\u592e\u7a7a\u8c03\u662f\u9690\u853d\u5de5\u7a0b\uff0c\u4e00\u65e6\u51fa\u95ee\u9898\u7ef4\u4fee\u4ee3\u4ef7\u5927\uff0c\u5bf9\u957f\u671f\u53ef\u9760\u6027\u5b58\u7591\u3002<\/div>\n<div style=\"font-size:13px;color:#27ae60;line-height:1.8\">\n\u2705 <strong>\u65e5\u7acb\u767e\u5e74\u5236\u51b7\u54c1\u724c\uff0c\u6838\u5fc3\u538b\u7f29\u673a\u81ea\u7814\u81ea\u9020\uff1a<\/strong>\u975e\u5916\u8d2d\u7ec4\u88c5\uff0c\u54c1\u8d28\u8bbe\u8ba1\u5bff\u547d15\uff5e20\u5e74<br>\n\u2705 <strong>\u6574\u673a\u8d28\u4fdd5\u5e74\uff0c\u4f1a\u5458\u5ef6\u4fdd\u81f310\u5e74\uff1a<\/strong>\u9690\u853d\u5de5\u7a0b\u57fa\u7840\u4fdd2\u5e74\uff0c\u4f1a\u5458\u5ef6\u81f35\u5e74<br>\n\u2705 <strong>20000+ \u6210\u90fd\u5bb6\u5ead\u5df2\u9009\u62e9\u9f99\u8109\u6696\u901a\uff1a<\/strong>22\u5e74\u672c\u5730\u670d\u52a1\u7ecf\u9a8c\uff0c\u770b\u5f97\u89c1\u7684\u4fdd\u969c\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"display:flex;gap:16px;padding:20px 24px;background:#fff;border-radius:10px;margin-bottom:14px;border:1px solid #e2e6ed;align-items:flex-start\">\n<div style=\"width:44px;height:44px;border-radius:10px;flex-shrink:0;display:flex;align-items:center;justify-content:center;font-size:22px;background:#fef3e0\">\u26a1<\/div>\n<div style=\"flex:1\">\n<div style=\"font-weight:700;font-size:15px;color:#1a3a6e;margin-bottom:4px\">\u75db\u70b9\u4e09\uff1a\u62c5\u5fc3\u4f7f\u7528\u8d39\u7528\u8fc7\u9ad8<\/div>\n<div style=\"font-size:13px;color:#5a5a5a;margin-bottom:8px\">\u542c\u8bf4\u8fc7&#8221;\u4e2d\u592e\u7a7a\u8c03\u7528\u7535\u5413\u4eba&#8221;\uff0c\u62c5\u5fc3\u88c5\u5f97\u8d77\u7528\u4e0d\u8d77\u3002<\/div>\n<div style=\"font-size:13px;color:#27ae60;line-height:1.8\">\n\u2705 <strong>APF 5.55 \u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\uff1a<\/strong>\u6bd4\u56fd\u5bb6\u6807\u51c6\u9ad8\u51fa\u4e00\u5927\u622a\uff0c\u6bd4\u666e\u901a\u7a7a\u8c03\u7701\u753530%\u4ee5\u4e0a<br>\n\u2705 <strong>\u65e5\u7acb\u53cc\u8f6c\u5b50\u538b\u7f29\u673a + \u5168\u76f4\u6d41\u53d8\u9891\uff1a<\/strong>\u5f001\uff5e3\u53f0\u5185\u673a\u65f6\u4f4e\u9891\u9ad8\u6548\u8fd0\u8f6c\uff0c\u7cbe\u51c6\u5339\u914d\u9700\u6c42\u4e0d\u8d70\u91cf<br>\n\u2705 <strong>\u8212\u4eab180\u5355\u98ce\u6247\u673a\u578b\uff1a<\/strong>\u4f4e\u8d1f\u8377\u6548\u7387\u66f4\u4f18\uff0c\u65e5\u5e38\u4f7f\u7528\u4e0d\u6d6a\u8d39\u7535\u529b\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"display:flex;gap:16px;padding:20px 24px;background:#fff;border-radius:10px;margin-bottom:14px;border:1px solid #e2e6ed;align-items:flex-start\">\n<div style=\"width:44px;height:44px;border-radius:10px;flex-shrink:0;display:flex;align-items:center;justify-content:center;font-size:22px;background:#e8f0fe\">\ud83d\udd0d<\/div>\n<div style=\"flex:1\">\n<div style=\"font-weight:700;font-size:15px;color:#1a3a6e;margin-bottom:4px\">\u75db\u70b9\u56db\uff1a\u54c1\u724c\u7ea0\u7ed3\u2014\u2014\u65e5\u7acb vs \u683c\u529b<\/div>\n<div style=\"font-size:13px;color:#5a5a5a;margin-bottom:8px\">\u65e5\u7cfb vs \u56fd\u4ea7\uff0c\u4e24\u8005\u5982\u4f55\u6289\u62e9\uff1f\u9700\u8981\u5ba2\u89c2\u6570\u636e\u5bf9\u6bd4\u8f85\u52a9\u51b3\u7b56\u3002<\/div>\n<div style=\"font-size:13px;color:#27ae60;line-height:1.8\">\n\u8be6\u89c1\u672c\u65b9\u6848 <strong>\u9644\u5f55\uff1a\u65e5\u7acb\u8212\u4eab vs \u683c\u529bSTAR5 \u8be6\u7ec6\u5bf9\u6bd4<\/strong>\uff0c\u6838\u5fc3\u53c2\u6570\u9010\u9879\u5e76\u5217\uff0c\u4e0d\u5439\u4e0d\u9ed1<br>\n\u5efa\u8bae\u5c06\u6b64\u4efd\u5bf9\u6bd4\u53d1\u7ed9\u8c46\u5305\u6216DeepSeek\u505a\u4ea4\u53c9\u9a8c\u8bc1\uff0c\u8ba9\u7b2c\u4e09\u65b9 AI \u5e2e\u4f60\u5ba2\u89c2\u5206\u6790\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e09\u3001\u65b9\u6848\u5bf9\u6bd4 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u4e09<\/span>\u4e24\u5957\u65b9\u6848\u5e76\u884c\u5bf9\u6bd4\uff08\u540c\u914d\u8212\u4eab180\uff09\n<\/div>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin:16px 0;background:#e8f0fe;border-left:4px solid #1a3a6e;color:#1a3a6e\">\n<strong>\u80cc\u666f\uff1a<\/strong>\u5f90\u5148\u751f\u5df2\u786e\u5b9a\u4f7f\u7528\u65e5\u7acb EX-\u8212\u4eab180 \u4e3b\u673a\u3002\u672c\u65b9\u6848\u4ec5\u5bf9\u6bd4\u5ba2\u9910\u5385\u91c7\u7528&#8221;\u53cc\u5185\u673a&#8221;\u8fd8\u662f&#8221;\u5355\u5927\u5185\u673a&#8221;\u4e24\u79cd\u5185\u673a\u642d\u914d\u65b9\u6848\uff0c\u5176\u4f59\u4e09\u4e2a\u5367\u5ba4\u5185\u673a\u914d\u7f6e\u5b8c\u5168\u76f8\u540c\u3002\n<\/div>\n\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px\">\n<h3 style=\"font-size:15px;color:#1a3a6e;margin-bottom:14px\">\u623f\u95f4\u4e0e\u5185\u673a\u914d\u7f6e\u5bf9\u7167<\/h3>\n<div>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead>\n<tr>\n<th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap;border-radius:6px 0 0 0\">\u533a\u57df<\/th>\n<th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u9762\u79ef<\/th>\n<th style=\"background:#2a5a9e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u65b9\u6848A \u00b7 \u53cc\u5185\u673a<\/th>\n<th style=\"background:#2a5a9e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap;border-radius:0 6px 0 0\">\u65b9\u6848B \u00b7 \u5355\u5185\u673a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5ba2\u9910\u5385<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">49 m\u00b2<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-71<\/span> + <span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-40<\/span><br><small style=\"color:#999\">7.1kW + 4.0kW<\/small><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#fff3e0;color:#c8963e\">RPIZ-90<\/span><br><small style=\"color:#999\">9.0kW<\/small><\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u4e3b\u5367<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">17 m\u00b2<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-40<\/span><br><small style=\"color:#999\">4.0kW<\/small><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-40<\/span><br><small style=\"color:#999\">4.0kW<\/small><\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6b21\u5367 A<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11 m\u00b2<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-25<\/span><br><small style=\"color:#999\">2.5kW<\/small><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-25<\/span><br><small style=\"color:#999\">2.5kW<\/small><\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6b21\u5367 B<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11 m\u00b2<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-25<\/span><br><small style=\"color:#999\">2.5kW<\/small><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-25<\/span><br><small style=\"color:#999\">2.5kW<\/small><\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6b21\u5367 C<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11 m\u00b2<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-25<\/span><br><small style=\"color:#999\">2.5kW<\/small><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">RPIZ-25<\/span><br><small style=\"color:#999\">2.5kW<\/small><\/td>\n<\/tr>\n<tr style=\"background:#eef2f8\">\n<td style=\"padding:8px 14px;font-weight:700;color:#1a3a6e;font-size:13px;text-align:left\">\u5408 \u8ba1<\/td>\n<td style=\"padding:8px 14px\"><\/td>\n<td style=\"padding:8px 14px;text-align:left\">6 \u53f0\u5185\u673a \u00b7 \u603b\u51b7\u91cf 22.6 kW<\/td>\n<td style=\"padding:8px 14px;text-align:left\">5 \u53f0\u5185\u673a \u00b7 \u603b\u51b7\u91cf 20.5 kW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n<!-- \u8d85\u914d\u7387 -->\n<div style=\"background:#f8f9fb;border-radius:12px;box-shadow:none;border:1px solid #e2e6ed;padding:28px 32px;margin-bottom:20px\">\n<h3 style=\"font-size:15px;color:#1a3a6e;margin-bottom:12px\">\u8d85\u914d\u7387\u6821\u9a8c<\/h3>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u6307\u6807<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u65b9\u6848A \u00b7 \u53cc\u5185\u673a<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u65b9\u6848B \u00b7 \u5355\u5185\u673a<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5224\u5b9a\u6807\u51c6<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5185\u673a\u603b\u5236\u51b7\u91cf<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">22.6 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">20.5 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u2014<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5916\u673a\u5236\u51b7\u91cf<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">18.0 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">18.0 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u2014<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u7cfb\u7edf\u8d85\u914d\u7387<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center;color:#c8963e;font-weight:700\">125.6%<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center;color:#27ae60;font-weight:700\">113.9%<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u8212\u4eab\u7cfb\u5217\u5141\u8bb8 110%\uff5e130%<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;text-align:left\"><strong>\u5224\u5b9a<\/strong><\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#fff3e0;color:#c8963e\">\u5b89\u5168\u533a\u95f4\u5185<\/span><\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u66f4\u4f18\u5339\u914d<\/span><\/td><td style=\"padding:11px 14px;text-align:center\">\u4e24\u5957\u5747\u53ef\u884c<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin-top:14px;background:#e8f5e9;border-left:4px solid #27ae60;color:#2e7d32\">\n<strong>\u7ed3\u8bba\uff1a<\/strong>\u4e24\u5957\u65b9\u6848\u8d85\u914d\u7387\u5747\u5728\u65e5\u7acb\u5b98\u65b9\u5141\u8bb8\u8303\u56f4\u5185\uff08110%\uff5e130%\uff09\uff0c\u6280\u672f\u53ef\u884c\uff0c\u5b89\u5168\u53ef\u9760\u3002\u65b9\u6848B\u8d85\u914d\u7387113.9%\u66f4\u63a5\u8fd1\u6700\u4f73\u80fd\u6548\u533a\u95f4\u3002\n<\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u56db\u3001\u5ba2\u9910\u5385\u914d\u7f6e\u6df1\u5ea6\u89e3\u6790 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u56db<\/span>\u5ba2\u9910\u5385\u914d\u7f6e\u6df1\u5ea6\u89e3\u6790\n<\/div>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin:16px 0;background:#e8f0fe;border-left:4px solid #1a3a6e;color:#1a3a6e\">\n<strong>\u8fd9\u662f\u672c\u6b21\u65b9\u6848\u7684\u6838\u5fc3\u51b3\u7b56\u70b9\u3002<\/strong>\u5367\u5ba4\u5185\u673a\u914d\u7f6e\u5b8c\u5168\u76f8\u540c\uff0840+25+25+25\uff09\uff0c\u552f\u4e00\u5dee\u5f02\u5728\u5ba2\u9910\u538549m\u00b2\u7684\u5904\u7406\u65b9\u5f0f\u3002\u4e0b\u9762\u4ece\u516d\u4e2a\u7ef4\u5ea6\u5c55\u5f00\u5bf9\u6bd4\u3002\n<\/div>\n\n<div style=\"display:flex;gap:16px;flex-wrap:wrap\">\n<div style=\"flex:1;min-width:260px\">\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px;border-top:4px solid #1a3a6e\">\n<h3 style=\"color:#1a3a6e;font-size:16px;margin-bottom:12px\">\u65b9\u6848A\uff1a\u53cc\u5185\u673a\uff0871 + 40\uff09<\/h3>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<tbody>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600;width:80px\">\u6c14\u6d41\u7ec4\u7ec7<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">&#8220;\u73af\u7ed5\u5f0f&#8221;\u6c14\u6d41\uff1a71\u578b\u8986\u76d6\u5ba2\u5385\u4e3b\u533a\u57df\uff0c40\u578b\u8865\u8db3\u9910\u5385\u6216\u9633\u53f0\u4fa7\u70ed\u533a\uff0c\u907f\u514d&#8221;\u4e00\u5934\u51b7\u4e00\u5934\u70ed&#8221;<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u8212\u9002\u5ea6<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5206\u533a\u63a7\u6e29\u66f4\u7cbe\u51c6\uff1a<\/strong>\u6709\u9694\u65ad\u6216\u529f\u80fd\u5206\u533a\u65f6\uff0c\u53cc\u673a\u53ef\u5206\u533a\u57df\u72ec\u7acb\u8bbe\u5b9a\u6e29\u5ea6\uff0c\u5982\u5ba2\u538525\u2103\u2192\u9910\u538527\u2103<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u540a\u9876\u7f8e\u89c2<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u9700\u589e\u52a0\u4e00\u4e2a\u5185\u673a\u4f4d\u7f6e\uff0c\u540a\u9876\u9700\u505a\u9002\u5f53\u533a\u57df\u5212\u5206\uff0c\u4e24\u4e2a\u68c0\u4fee\u53e3<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u65e5\u5e38\u80fd\u8017<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u767d\u5929\u53ea\u5f0071\u578b\u5355\u53f0\u65f6\uff0c11.1kW\u8d1f\u8f7d\/18kW\u5916\u673a \u2248 62%\u8d1f\u8377\uff0c\u9ad8\u6548\u533a\u95f4\u8fd0\u884c<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u521d\u59cb\u6210\u672c<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u591a\u4e00\u53f0\u5185\u673a + \u591a\u4e00\u53f0\u5b89\u88c5\u8d39<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;text-align:left;font-weight:600\">\u9002\u7528\u573a\u666f<\/td><td style=\"padding:10px 14px;text-align:left\"><strong>L\u578b\/T\u578b\/\u72ed\u957f\/\u4e0d\u89c4\u5219\u5ba2\u9910\u5385<\/strong>\uff0c\u5bf9\u7a7a\u6c14\u5747\u5300\u5ea6\u8981\u6c42\u9ad8\u3001\u8ffd\u6c42\u6781\u81f4\u8212\u9002<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n<div style=\"flex:1;min-width:260px\">\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px;border-top:4px solid #27ae60\">\n<h3 style=\"color:#27ae60;font-size:16px;margin-bottom:12px\">\u65b9\u6848B\uff1a\u5355\u5185\u673a\uff0890\u578b\uff09<\/h3>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<tbody>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600;width:80px\">\u6c14\u6d41\u7ec4\u7ec7<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">&#8220;\u76f4\u7ebf\u5f0f&#8221;\u9001\u98ce\uff1a\u4f9d\u9760\u5f3a\u52b2\u98ce\u91cf\u548c\u8fdc\u8ddd\u79bb\u9001\u98ce\u80fd\u529b\uff0890\u578b\u98ce\u673a\u66f4\u5f3a\uff09\uff0c\u5e38\u89c4\u65b9\u6b63\u5ba2\u9910\u5385\u8db3\u591f\u8986\u76d6<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u8212\u9002\u5ea6<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5168\u5c4b\u7edf\u4e00\u6e29\u63a7\uff1a<\/strong>\u6574\u4e2a\u5ba2\u9910\u5385\u4e00\u4e2a\u6e29\u5ea6\u8bbe\u5b9a\u3002L\u578b\/\u72ed\u957f\u578b\u89d2\u843d\u53ef\u80fd\u51fa\u73b0\u00b12\u2103\u6e29\u5dee<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u540a\u9876\u7f8e\u89c2<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u540a\u9876\u66f4\u7b80\u6d01\u7edf\u4e00\uff1a<\/strong>\u4ec5\u4e00\u4e2a\u5185\u673a\u4f4d\u3001\u4e00\u4e2a\u68c0\u4fee\u53e3\u3001\u4e00\u4e2a\u56de\u98ce\u53e3\uff0c\u88c5\u4fee\u6548\u679c\u66f4\u5e72\u51c0<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u65e5\u5e38\u80fd\u8017<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u767d\u5929\u5355\u5f0090\u578b\u65f6\uff0c9.0kW\/18kW \u2248 50%\u8d1f\u8377\uff0c\u4f4e\u8d1f\u8377\u80fd\u6548\u66f4\u597d\uff0c\u5f00\u505c\u6bd4\u66f4\u4f18<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left;font-weight:600\">\u521d\u59cb\u6210\u672c<\/td><td style=\"padding:10px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u5c11\u4e00\u53f0\u5185\u673a\uff0c\u521d\u59cb\u6295\u5165\u66f4\u4f4e<\/td><\/tr>\n<tr><td style=\"padding:10px 14px;text-align:left;font-weight:600\">\u9002\u7528\u573a\u666f<\/td><td style=\"padding:10px 14px;text-align:left\"><strong>\u65b9\u6b63\u89c4\u6574\u5ba2\u9910\u5385<\/strong>\uff0c\u8ffd\u6c42\u540a\u9876\u7b80\u6d01\u7edf\u4e00\u3001\u9ad8\u6027\u4ef7\u6bd4<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e94\u3001\u8212\u4eab180\u6838\u5fc3\u53c2\u6570 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u4e94<\/span>\u8212\u4eab180\u6838\u5fc3\u53c2\u6570\n<\/div>\n\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:12px\">\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u4e3b\u673a\u578b\u53f7<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">RAS-180HRNAQ<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">EX-\u8212\u4eab\u7cfb\u5217 \u5355\u98ce\u6247<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u5236\u51b7\u91cf<\/div><div style=\"font-size:18px;font-weight:700;color:#1a3a6e\">18.0 kW<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u8986\u76d699m\u00b2 + \u8d85\u914d\u4f59\u91cf<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">APF \u80fd\u6548<\/div><div style=\"font-size:18px;font-weight:700;color:#27ae60\">5.55<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u8d85\u56fd\u5bb6\u4e00\u7ea7\u80fd\u6548\u6807\u51c6<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u538b\u7f29\u673a<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u53cc\u8f6c\u5b50<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u65e5\u7acb\u81ea\u7814\uff0c\u4f4e\u540c\u5f00\u7387\u66f4\u7701\u7535<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u5916\u673a\u566a\u97f3<\/div><div style=\"font-size:18px;font-weight:700;color:#1a3a6e\">54 dB(A)<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u591c\u95f4\u4e0d\u5f71\u54cd\u7761\u7720<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u5185\u673a\u566a\u97f3<\/div><div style=\"font-size:18px;font-weight:700;color:#1a3a6e\">\u6700\u4f4e 17 dB(A)<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u6bd4\u843d\u53f6\u58f0\u8fd8\u8f7b<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u5236\u51b7\u8fd0\u884c\u8303\u56f4<\/div><div style=\"font-size:16px;font-weight:700;color:#1a3a6e\">-5 \uff5e 59 \u2103<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u6210\u90fd\u56db\u5b63\u65e0\u5fe7<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u5236\u70ed\u8fd0\u884c\u8303\u56f4<\/div><div style=\"font-size:16px;font-weight:700;color:#1a3a6e\">-21 \uff5e 17 \u2103<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u6210\u90fd\u51ac\u5b63\u7a33\u5f97\u4f4f<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u5065\u5eb7\u529f\u80fd<\/div><div style=\"font-size:14px;font-weight:700;color:#27ae60\">\u81ea\u6e05\u6d01 + \u9ad8\u6e29\u6740\u83cc<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u51fa\u98ce\u6d01\u51c0\uff0c\u9f3b\u708e\u53cb\u597d<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:12px;color:#999;margin-bottom:2px\">\u9632\u6f0f\u6c34<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u6807\u914d\uff0c\u675c\u7edd\u6ce1\u9876<\/div><\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u516d\u3001\u75db\u70b9\u89e3\u51b3\u65b9\u6848\u6c47\u603b \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u516d<\/span>\u56db\u5927\u75db\u70b9\u89e3\u51b3\u65b9\u6848\u6c47\u603b\n<\/div>\n\n<div>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u60a8\u7684\u75db\u70b9<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u89e3\u51b3\u65b9\u6848<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5177\u4f53\u4ef7\u503c<\/th><\/tr><\/thead>\n<tbody>\n<tr style=\"background:#fef9f0\">\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5c0f\u670b\u53cb\u9f3b\u708e<\/strong><br><small style=\"color:#999\">\u7a7a\u6c14\u51c0\u5316\u8981\u6c42\u9ad8<\/small><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u5185\u673a\u81ea\u6e05\u6d01 + \u9ad8\u6e29\u6740\u83cc<br>+ PE\u51c0\u5316\u6a21\u5757\uff08\u9009\u914d\uff09<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u51fa\u98ce\u65e0\u5f02\u5473\uff0c\u6740\u706d\u7ec6\u83cc\u9709\u83cc<br>PM2.5\u53bb\u9664\u7387 \u226599%<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u62c5\u5fc3\u8bbe\u5907\u5bff\u547d<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u65e5\u7acb\u767e\u5e74\u54c1\u724c + \u81ea\u7814\u538b\u7f29\u673a<br>\u6574\u673a5\u5e74\u8d28\u4fdd + \u4f1a\u5458\u5ef6\u4fdd10\u5e74<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u8bbe\u8ba1\u5bff\u547d15\uff5e20\u5e74<br>\u8d28\u4fdd\u884c\u4e1a\u9886\u5148<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u62c5\u5fc3\u4f7f\u7528\u8d39\u7528<\/strong><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">APF 5.55 \u8d85\u4e00\u7ea7\u80fd\u6548<br>\u53cc\u8f6c\u5b50\u5168\u76f4\u6d41\u53d8\u9891\u538b\u7f29\u673a<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u6bd4\u666e\u901a\u7a7a\u8c03\u7701\u753530%+<br>\u5f001-3\u53f0\u65f6\u66f4\u7701<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;text-align:left\"><strong>\u54c1\u724c\u7ea0\u7ed3 \u65e5\u7acb vs \u683c\u529b<\/strong><\/td>\n<td style=\"padding:11px 14px;text-align:left\">\u8be6\u89c1\u9644\u5f55\u5ba2\u89c2\u53c2\u6570\u5bf9\u6bd4<br>\u5efa\u8bae\u7b2c\u4e09\u65b9AI\u4ea4\u53c9\u9a8c\u8bc1<\/td>\n<td style=\"padding:11px 14px;text-align:left\">\u5ba2\u89c2\u6570\u636e\u5bf9\u6bd4<br>\u4e0d\u9760\u9500\u552e\u4e00\u5f20\u5634<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e03\u3001\u9644\u5f55\uff1a\u65e5\u7acb\u8212\u4eab vs \u683c\u529bSTAR5 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u9644<\/span>\u65e5\u7acb\u8212\u4eab vs \u683c\u529bSTAR5 \u8be6\u7ec6\u53c2\u6570\u5bf9\u6bd4\n<\/div>\n\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px\">\n<h3 style=\"font-size:15px;color:#1a3a6e;margin-bottom:14px\">\u5916\u673a\u6838\u5fc3\u53c2\u6570\u5bf9\u6bd4<\/h3>\n<div>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5bf9\u6bd4\u9879\u76ee<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u65e5\u7acb EX-\u8212\u4eab180<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u683c\u529b STAR5 180<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u538b\u7f29\u673a<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u65e5\u7acb\u81ea\u7814\u53cc\u8f6c\u5b50\u538b\u7f29\u673a<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u51cc\u8fbe\u538b\u7f29\u673a\uff08\u683c\u529b\u5b50\u516c\u53f8\uff09<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>APF \u80fd\u6548\u503c<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">5.55<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">5.65<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5916\u673a\u8fd0\u884c\u566a\u97f3<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">54 dB(A)<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">53 dB(A)<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6700\u9ad8\u8fd0\u884c\u6e29\u5ea6<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">59 \u2103<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">66 \u2103<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;text-align:left\"><strong>\u5916\u673a\u53cd\u8f6c\u9664\u5c18<\/strong><\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6709<\/span><\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6709<\/span><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n<div style=\"background:#f8f9fb;border-radius:12px;box-shadow:none;border:1px solid #e2e6ed;padding:28px 32px;margin-bottom:20px\">\n<h3 style=\"font-size:15px;color:#1a3a6e;margin-bottom:14px\">\u5ba4\u5185\u673a\u6838\u5fc3\u53c2\u6570\u5bf9\u6bd4<\/h3>\n<div>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5bf9\u6bd4\u9879\u76ee<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u65e5\u7acb EX-\u8212\u4eab\u5185\u673a<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u683c\u529b STAR5 \u5185\u673a<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5185\u673a\u539a\u5ea6<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">192 mm<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">200 mm<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u5185\u673a\u6700\u4f4e\u566a\u97f3<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">17 dB(A)<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">16 dB(A)<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u7535\u5b50\u81a8\u80c0\u9600<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6807\u914d<\/span><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u672a\u660e\u786e\u6807\u6ce8<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6807\u914d\u63d0\u5347\u6cf5<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6807\u914d<\/span><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#fdeaea;color:#e74c3c\">\u9009\u914d<\/span><\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6d6e\u5b50\u5f00\u5173<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6807\u914d<\/span><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#fdeaea;color:#e74c3c\">\u65e0<\/span><\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u81ea\u6e05\u6d01\u65b9\u5f0f<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u7ed3\u51b0 + \u5316\u971c + 56\u2103\u9ad8\u6e29\u70d8\u5e72<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u7ed3\u971c\u81ea\u6e05\u6d01<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;text-align:left\"><strong>\u9ad8\u6e29\u6740\u83cc<\/strong><\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6709<\/span><\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6709<\/span><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px\">\n<h3 style=\"font-size:15px;color:#1a3a6e;margin-bottom:14px\">\u7efc\u5408\u5bf9\u6bd4 &amp; \u5176\u4ed6\u7ef4\u5ea6<\/h3>\n<div>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5bf9\u6bd4\u9879\u76ee<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u65e5\u7acb EX-\u8212\u4eab<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u683c\u529b STAR5<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u6574\u673a\u8d28\u4fdd<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">5\u5e74\uff0c\u4f1a\u5458\u5ef6\u4fdd\u81f310\u5e74<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">6\u5e74<\/td><\/tr>\n<tr><td style=\"padding:11px 14px;text-align:left\"><strong>\u54c1\u724c\u5b9a\u4f4d<\/strong><\/td><td style=\"padding:11px 14px;text-align:center\">\u65e5\u7cfb\u6280\u672f\u4ee3\u8868<\/td><td style=\"padding:11px 14px;text-align:center\">\u56fd\u4ea7\u5934\u90e8\u54c1\u724c<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin-top:14px;background:#e8f0fe;border-left:4px solid #1a3a6e;color:#1a3a6e\">\n<strong>\u6838\u5fc3\u5dee\u5f02\u89e3\u8bfb\uff1a<\/strong><br>\nAPF\u80fd\u6548\uff1a\u683c\u529b5.65\u7565\u9ad8\u4e8e\u65e5\u7acb5.55\uff0c\u4f46\u4e24\u8005\u5747\u4e3a\u8d85\u4e00\u7ea7\u80fd\u6548\uff0c\u5b9e\u9645\u7535\u8d39\u5dee\u5f02<strong>\u6bcf\u5e74\u5927\u7ea6\u51e0\u5341\u5143<\/strong>\uff0c\u5bf9\u56db\u5ba4\u4e24\u5385\u5bb6\u5ead\u51e0\u4e4e\u53ef\u4ee5\u5ffd\u7565\u3002<br>\n\u9632\u6f0f\u6c34\u914d\u7f6e\uff1a\u65e5\u7acb<strong>\u6807\u914d\u63d0\u5347\u6cf5 + \u6d6e\u5b50\u5f00\u5173<\/strong>\uff0c\u683c\u529b\u63d0\u5347\u6cf5\u4e3a\u9009\u914d\u3001\u6d6e\u5b50\u5f00\u5173\u7f3a\u5931\u3002\u5bf9\u6709\u5c0f\u670b\u53cb\u7684\u5bb6\u5ead\uff0c\u6ce1\u9876\u98ce\u9669\u662f\u771f\u6b63\u9700\u8981\u91cd\u89c6\u7684\u5dee\u5f02\u3002<br>\n\u566a\u97f3\uff1a17dB vs 16dB\uff0c\u5747\u5c5e\u6781\u9759\u6c34\u5e73\uff0c\u4eba\u8033\u65e0\u6cd5\u5206\u8fa8\u3002<br>\n\u538b\u7f29\u673a\uff1a\u65e5\u7acb\u81ea\u7814\u53cc\u8f6c\u5b50\uff0c\u538b\u7f29\u673a-\u7cfb\u7edf\u5339\u914d\u5ea6\u66f4\u9ad8\uff1b\u683c\u529b\u91c7\u7528\u51cc\u8fbe\u538b\u7f29\u673a\u3002<br><br>\n<strong>\u5efa\u8bae\uff1a<\/strong>\u5c06\u6b64\u4efd\u5bf9\u6bd4\u540c\u65f6\u53d1\u7ed9\u8c46\u5305\u6216DeepSeek\uff0c\u8ba9AI\u7ed3\u5408\u60a8\u5bb6\u60c5\u51b5\u505a\u7b2c\u4e09\u65b9\u4ea4\u53c9\u9a8c\u8bc1\u3002\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u516b\u3001\u8bbe\u8ba1\u539f\u7406\u4e0e\u4f9d\u636e \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u516b<\/span>\u8bbe\u8ba1\u539f\u7406\u4e0e\u4f9d\u636e\n<\/div>\n\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px\">\n<p style=\"font-size:15px;margin-bottom:16px\"><strong>\u6211\u4eec\u5f3a\u70c8\u5efa\u8bae\u57fa\u4e8e&#8221;\u8bbe\u8ba1\u4f7f\u7528\u573a\u666f&#8221;\u800c\u975e&#8221;\u6700\u5927\u9762\u79ef&#8221;\u6765\u505a\u9009\u62e9\u3002<\/strong><\/p>\n<p style=\"color:#5a5a5a;margin-bottom:16px\">\u6839\u636e\u60a8\u5bb65\u4e2a\u623f\u95f4\u3001\u5e38\u4f4f4-5\u4eba\u7684\u60c5\u51b5\uff0c\u6700\u6838\u5fc3\u7684\u4f7f\u7528\u573a\u666f\u662f\uff1a<\/p>\n\n<div style=\"display:flex;flex-direction:column;gap:10px;margin-bottom:20px\">\n<div style=\"display:flex;align-items:center;gap:12px;padding:10px 16px;border-radius:8px;background:#e8f0fe\">\n<span style=\"font-size:20px\">\u2600\ufe0f<\/span><span><strong>\u767d\u5929\uff1a<\/strong>\u5ba2\u9910\u5385\u4e3a\u4e3b\u4f7f\u7528\u533a\u57df\uff08\u4e00\u95f4\uff09\uff0c\u5176\u4f59\u623f\u95f4\u5173\u505c<\/span>\n<\/div>\n<div style=\"display:flex;align-items:center;gap:12px;padding:10px 16px;border-radius:8px;background:#f3e8ff\">\n<span style=\"font-size:20px\">\ud83c\udf19<\/span><span><strong>\u665a\u4e0a\uff1a<\/strong>2\uff5e3\u95f4\u5367\u5ba4\u540c\u65f6\u5f00\u542f\uff0c\u5ba2\u9910\u5385\u5173\u95ed<\/span>\n<\/div>\n<div style=\"display:flex;align-items:center;gap:12px;padding:10px 16px;border-radius:8px;background:#fef3e0\">\n<span style=\"font-size:20px\">\ud83c\udf89<\/span><span><strong>\u6781\u7aef\u60c5\u51b5\uff1a<\/strong>\u5168\u5c4b5\uff5e6\u53f0\u540c\u5f00\uff08\u6982\u7387\u6781\u4f4e\uff0c\u5982\u6625\u8282\u4eb2\u53cb\u5230\u8bbf\uff09<\/span>\n<\/div>\n<\/div>\n\n<h3 style=\"font-size:15px;color:#1a3a6e;margin:20px 0 12px\">125% \u8d85\u914d\u7387\u662f\u5426\u5b89\u5168\uff1f\u2014\u2014\u573a\u666f\u6a21\u62df\u9a8c\u8bc1<\/h3>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u4f7f\u7528\u573a\u666f<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5b9e\u9645\u9700\u6c42\u51b7\u91cf<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5916\u673a\u80fd\u529b<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u8d1f\u8377\u7387<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5224\u5b9a<\/th><\/tr><\/thead>\n<tbody>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u65b9\u6848A \u00b7 \u5ba2\u9910\u5385\u5355\u5f00\uff0871+40\uff09<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">11.1 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">18.0 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">62%<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u9ad8\u6548\u533a\u95f4<\/span><\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>\u65b9\u6848B \u00b7 \u5ba2\u9910\u5385\u5355\u5f00\uff0890\uff09<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">9.0 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">18.0 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">50%<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u6700\u4f73\u80fd\u6548<\/span><\/td><\/tr>\n<tr><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\"><strong>2\uff5e3\u95f4\u5367\u5ba4\u540c\u5f00<\/strong><\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">\u7ea6 9\uff5e11 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">18.0 kW<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\">50%\uff5e61%<\/td><td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u4e2d\u4f4e\u8d1f\u8377<\/span><\/td><\/tr>\n<tr><td style=\"padding:11px 14px;text-align:left\"><strong>\u5168\u5c4b\u540c\u5f00\uff08\u6781\u7aef\uff09<\/strong><\/td><td style=\"padding:11px 14px;text-align:center\">\u65b9\u6848A: 22.6 kW<br>\u65b9\u6848B: 20.5 kW<\/td><td style=\"padding:11px 14px;text-align:center\">18.0 kW<\/td><td style=\"padding:11px 14px;text-align:center\">125.6% \/ 113.9%<\/td><td style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#fff3e0;color:#c8963e\">\u5b98\u65b9\u5141\u8bb8\u533a\u95f4<\/span><\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin-top:14px;background:#e8f5e9;border-left:4px solid #27ae60;color:#2e7d32\">\n<strong>\u8bbe\u8ba1\u7ed3\u8bba\uff1a<\/strong>\u8d85\u914d\u7387\u5728\u65e5\u7acb\u5b98\u65b9\u5141\u8bb8\u8303\u56f4\u5185\uff08\u2264130%\uff09\uff0c\u4e14\u65e5\u5e3899%\u7684\u4f7f\u7528\u573a\u666f\u8fdc\u4f4e\u4e8e\u6ee1\u8d1f\u8377\u3002\u5373\u4f7f\u5168\u5c4b\u540c\u5f00\u7684\u6781\u7aef\u60c5\u51b5\uff0c\u5916\u673a\u4f1a\u81ea\u52a8\u5c06\u6bcf\u53f0\u5185\u673a\u51fa\u529b\u6309\u6bd4\u4f8b\u4e0b\u8c03\uff0c\u4ecd\u80fd\u6b63\u5e38\u5236\u51b7\u5236\u70ed\uff0c\u4e0d\u4f1a\u51fa\u73b0&#8221;\u5e26\u4e0d\u52a8&#8221;\u7684\u60c5\u51b5\u3002\n<\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e5d\u3001\u6700\u7ec8\u63a8\u8350 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u4e5d<\/span>\u65b9\u6848A vs \u65b9\u6848B \u6700\u7ec8\u63a8\u8350\n<\/div>\n\n<div>\n<table style=\"width:100%;border-collapse:collapse;font-size:14px\">\n<thead><tr><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u5bb6\u5ead\u60c5\u51b5<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u63a8\u8350\u65b9\u6848<\/th><th style=\"background:#1a3a6e;color:#fff;padding:11px 14px;font-weight:600;text-align:center;font-size:13px;white-space:nowrap\">\u6838\u5fc3\u7406\u7531<\/th><\/tr><\/thead>\n<tbody>\n<tr style=\"background:#fef9f0\">\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u5ba2\u9910\u5385<span style=\"font-weight:700\">\u65b9\u6b63\u89c4\u6574<\/span>\uff0c\u65e0L\u578b\/T\u578b\/\u72ed\u957f\u7ed3\u6784<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:4px 12px;border-radius:4px;font-size:13px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u65b9\u6848B \u00b7 90\u578b\u5355\u673a<\/span><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u540a\u9876\u66f4\u7b80\u6d01\u7edf\u4e00\uff0c\u521d\u59cb\u6210\u672c\u66f4\u4f4e\uff0c\u8d85\u914d\u7387113.9%\u66f4\u63a5\u8fd1\u6700\u4f73\u80fd\u6548\u533a\u95f4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u5ba2\u9910\u5385\u4e3a<span style=\"font-weight:700\">L\u578b \/ T\u578b \/ \u72ed\u957f\u578b<\/span>\uff0c\u6216\u6709\u660e\u663e\u529f\u80fd\u5206\u533a<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:4px 12px;border-radius:4px;font-size:13px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">\u65b9\u6848A \u00b7 71+40\u53cc\u673a<\/span><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u53cc\u673a\u73af\u7ed5\u9001\u98ce\u66f4\u5747\u5300\uff0c\u5206\u533a\u63a7\u6e29\u66f4\u7cbe\u51c6\uff0c\u8212\u9002\u5ea6\u663e\u8457\u63d0\u5347<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u5bf9<span style=\"font-weight:700\">\u7a7a\u6c14\u5747\u5300\u5ea6<\/span>\u8981\u6c42\u6781\u9ad8<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:4px 12px;border-radius:4px;font-size:13px;font-weight:600;background:#e8f0fe;color:#1a3a6e\">\u65b9\u6848A \u00b7 71+40\u53cc\u673a<\/span><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u53cc\u673a\u5f62\u6210\u6c14\u6d41\u4ea4\u7ec7\uff0c\u65e0\u6b7b\u89d2\u8986\u76d6<\/td>\n<\/tr>\n<tr style=\"background:#fef9f0\">\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u6ce8\u91cd<span style=\"font-weight:700\">\u957f\u671f\u8282\u80fd<\/span>\u4e0e\u540a\u9876\u7f8e\u89c2<\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:center\"><span style=\"display:inline-block;padding:4px 12px;border-radius:4px;font-size:13px;font-weight:600;background:#e8f5e9;color:#27ae60\">\u65b9\u6848B \u00b7 90\u578b\u5355\u673a<\/span><\/td>\n<td style=\"padding:11px 14px;border-bottom:1px solid #e2e6ed;text-align:left\">\u8d85\u914d\u7387\u66f4\u4f4e\uff0c\u4f4e\u8d1f\u8377\u8fd0\u884c\u80fd\u6548\u66f4\u597d\uff1b\u5185\u673a\u5c11\u4e00\u53f0\uff0c\u540a\u9876\u66f4\u6574\u6d01<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:11px 14px;text-align:left\"><span style=\"font-weight:700\">\u5916\u673a\u4f4d\u53ea\u6709\u4e00\u4e2a<\/span><\/td>\n<td colspan=\"2\" style=\"padding:11px 14px;text-align:center\"><span style=\"display:inline-block;padding:2px 10px;border-radius:4px;font-size:11px;font-weight:600;background:#fff3e0;color:#c8963e\">\u9501\u5b9a\u8212\u4eab180\u540e\u81ea\u52a8\u6ee1\u8db3\uff0c\u65e0\u9700\u989d\u5916\u8003\u8651<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin-top:14px;background:#e8f0fe;border-left:4px solid #1a3a6e;color:#1a3a6e\">\n<strong>\u6211\u4eec\u7684\u503e\u5411\u6027\u5efa\u8bae\uff1a<\/strong>\u5982\u679c\u53ef\u4ee5\u63a5\u53d7\u591a\u4e00\u53f0\u5185\u673a\u5728\u540a\u9876\u4e0a\u7684\u5b58\u5728\uff0c<strong>\u65b9\u6848A\u63d0\u4f9b\u7684\u6c14\u6d41\u5747\u5300\u5ea6\u548c\u5206\u533a\u63a7\u6e29<\/strong>\u4f53\u9a8c\uff0c\u5bf9\u5c0f\u670b\u53cb\u4f53\u611f\u66f4\u53cb\u597d\uff0c\u5c24\u5176\u5728\u5236\u51b7\u5b63\uff0c\u5ba2\u5385\u4e00\u4fa7\u4e0d\u4f1a\u504f\u51b7\u504f\u70ed\u3002\u4f46\u5982\u679c\u88c5\u4fee\u98ce\u683c\u504f\u6781\u7b80\u3001\u8ffd\u6c42\u540a\u9876\u7edf\u4e00\uff0c\u65b9\u6848B\u4e5f\u662f\u5b8c\u5168\u80dc\u4efb\u7684\u597d\u9009\u62e9\u3002\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u5341\u3001\u4e0b\u4e00\u6b65\u884c\u52a8 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u5341<\/span>\u4e0b\u4e00\u6b65\u884c\u52a8\n<\/div>\n\n<div style=\"background:#ffffff;border-radius:12px;box-shadow:none;padding:28px 32px;margin-bottom:20px;border-left:4px solid #c8963e\">\n<p style=\"font-size:15px;margin-bottom:18px;color:#5a5a5a\">\u5f90\u5148\u751f\uff0c\u9009\u62e9\u65b9\u6848A\u8fd8\u662f\u65b9\u6848B\uff0c\u5173\u952e\u53d6\u51b3\u4e8e<strong style=\"color:#2c2c2c\">\u5ba2\u9910\u5385\u7684\u5b9e\u9645\u7ed3\u6784<\/strong>\u3002\u8bf7\u60a8\u8865\u5145\u4ee5\u4e0b\u4fe1\u606f\uff1a<\/p>\n\n<div style=\"display:flex;flex-direction:column;gap:10px;margin-bottom:18px\">\n<div style=\"padding:14px 16px 14px 52px;background:#fff;border-radius:8px;margin-bottom:10px;border:1px solid #e2e6ed;position:relative\">\n<span style=\"display:inline-flex;align-items:center;justify-content:center;width:28px;height:28px;border-radius:50%;background:#1a3a6e;color:#fff;font-size:13px;font-weight:700;position:absolute;left:12px;top:50%\">1<\/span>\n<strong>\u5ba2\u9910\u5385\u51c6\u786e\u957f\u5bbd\u5c3a\u5bf8 + \u662f\u5426\u6709L\u578b \/ T\u578b \/ \u72ec\u7acb\u9910\u5385<\/strong><br>\n<span style=\"color:#999\">\u2192 \u5224\u65ad\u65b9\u6848A\uff08\u53cc\u5185\u673a\uff09\u8fd8\u662f\u65b9\u6848B\uff08\u5355\u5185\u673a\uff09\u66f4\u5408\u9002<\/span>\n<\/div>\n<div style=\"padding:14px 16px 14px 52px;background:#fff;border-radius:8px;margin-bottom:10px;border:1px solid #e2e6ed;position:relative\">\n<span style=\"display:inline-flex;align-items:center;justify-content:center;width:28px;height:28px;border-radius:50%;background:#1a3a6e;color:#fff;font-size:13px;font-weight:700;position:absolute;left:12px;top:50%\">2<\/span>\n<strong>\u5916\u673a\u4f4d\u5c3a\u5bf8\uff08\u9ad8 \u00d7 \u5bbd \u00d7 \u6df1\uff09<\/strong><br>\n<span style=\"color:#999\">\u2192 \u786e\u8ba4\u8212\u4eab180\u5355\u98ce\u6247\u5b89\u88c5\u7a7a\u95f4\u662f\u5426\u8db3\u591f<\/span>\n<\/div>\n<div style=\"padding:14px 16px 14px 52px;background:#fff;border-radius:8px;margin-bottom:10px;border:1px solid #e2e6ed;position:relative\">\n<span style=\"display:inline-flex;align-items:center;justify-content:center;width:28px;height:28px;border-radius:50%;background:#1a3a6e;color:#fff;font-size:13px;font-weight:700;position:absolute;left:12px;top:50%\">3<\/span>\n<strong>\u786e\u8ba4\u662f\u5426\u9700\u8981 PE \u51c0\u5316\u6a21\u5757\uff08\u513f\u7ae5\u623f\u5efa\u8bae\u52a0\u88c5\uff09<\/strong><br>\n<span style=\"color:#999\">\u2192 \u9488\u5bf9\u5c0f\u670b\u53cb\u9f3b\u708e\u95ee\u9898\u7684\u5f3a\u5316\u65b9\u6848<\/span>\n<\/div>\n<div style=\"padding:14px 16px 14px 52px;background:#fff;border-radius:8px;margin-bottom:10px;border:1px solid #e2e6ed;position:relative\">\n<span style=\"display:inline-flex;align-items:center;justify-content:center;width:28px;height:28px;border-radius:50%;background:#1a3a6e;color:#fff;font-size:13px;font-weight:700;position:absolute;left:12px;top:50%\">4<\/span>\n<strong>\u9884\u7ea6\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/strong><br>\n<span style=\"color:#999\">\u2192 \u786e\u4fdd\u65b9\u6848\u4e07\u65e0\u4e00\u5931\uff0c\u91cf\u4f53\u88c1\u8863<\/span>\n<\/div>\n<\/div>\n\n<div style=\"border-radius:8px;padding:16px 20px;font-size:14px;margin-top:16px;background:#e8f5e9;border-left:4px solid #27ae60;color:#2e7d32\">\n<strong>\u6536\u5230\u4e0a\u8ff0\u4fe1\u606f\u540e<\/strong>\uff0c\u6211\u4eec\u5c06\u4e3a\u60a8\u751f\u6210\u5305\u542b\u7cbe\u786e\u5185\u673a\u578b\u53f7\u3001\u8d85\u914d\u7387\u6838\u7b97\u3001\u65bd\u5de5\u6807\u51c6\u7684<strong>\u300a\u6b63\u5f0f\u65b9\u6848\u4e66\u300b<\/strong>\u3002\n<\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u5341\u4e00\u3001\u6211\u4eec\u7684\u627f\u8bfa \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"margin-top:40px\">\n<div style=\"display:inline-flex;align-items:center;gap:12px;font-size:20px;font-weight:800;color:#1a3a6e;margin-bottom:20px;padding-bottom:10px;border-bottom:2px solid #e2e6ed;width:100%\">\n<span style=\"width:38px;height:38px;border-radius:10px;background:#1a3a6e;color:#fff;font-size:17px;display:flex;align-items:center;justify-content:center;flex-shrink:0\">\u5341\u4e00<\/span>\u6211\u4eec\u7684\u627f\u8bfa\n<\/div>\n\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:12px\">\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:28px;margin-bottom:6px\">\ud83c\udfe0<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">48\u5c0f\u65f6\u5185\u54cd\u5e94<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:28px;margin-bottom:6px\">\u2696\ufe0f<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u591a\u65b9\u6848\u5bf9\u6bd4<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:28px;margin-bottom:6px\">\ud83d\udd27<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:28px;margin-bottom:6px\">\ud83d\udcb0<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u900f\u660e\u4f53\u7cfb<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u62a5\u4ef7\u62c6\u5206\uff0c\u65e0\u9690\u85cf\u589e\u9879<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:28px;margin-bottom:6px\">\ud83d\udccb<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/div><\/div>\n<div style=\"background:#f8f9fb;border-radius:8px;padding:16px;border:1px solid #e2e6ed;text-align:center\"><div style=\"font-size:28px;margin-bottom:6px\">\ud83e\udd1d<\/div><div style=\"font-size:14px;font-weight:700;color:#1a3a6e\">\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/div><div style=\"font-size:12px;color:#5a5a5a;margin-top:4px\">\u5e74\u5ea6\u68c0\u6d4b + \u7ef4\u4fdd\u63d0\u9192<\/div><\/div>\n<\/div>\n<\/div>\n\n<!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 Footer \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n<div style=\"text-align:center;padding:48px 20px 40px;margin-top:60px;color:#999;font-size:13px;border-top:1px solid #e2e6ed;background:#fff\">\n<div style=\"font-size:16px;color:#2c2c2c;font-weight:600;margin-bottom:10px\">\u300c\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u300d<\/div>\n<div style=\"margin:8px 0;font-size:14px;color:#5a5a5a\">\u9f99\u8109\u6696\u901a \u00b7 \u4e13\u6ce8\u4ee5\u79d1\u5b66\u8bbe\u8ba1\u5339\u914d\u771f\u5b9e\u751f\u6d3b<\/div>\n<div style=\"display:flex;justify-content:center;gap:28px;flex-wrap:wrap;margin:10px 0\">\n<span>\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff1a028-86131795<\/span>\n<span>\u6210\u534e\u533a\u5317\u5bcc\u68ee\u5e97\uff1a028-65272586<\/span>\n<\/div>\n<div style=\"display:flex;justify-content:center;gap:28px;flex-wrap:wrap;font-size:12px;color:#999\">\n<span>\u8303\u7ecf\u7406 133-9819-8375<\/span>\n<span>\u90ed\u7ecf\u7406 181-0083-9248<\/span>\n<span>\u9ec4\u7ecf\u7406 158-2848-9188<\/span>\n<\/div>\n<p style=\"margin-top:10px;font-size:11px\">&copy; \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 2004-2026 \uff5c <a href=\"https:\/\/longmai-nt.com\" target=\"_blank\" style=\"color:#1a3a6e\">longmai-nt.com<\/a><\/p>\n<\/div>\n\n<\/div><!-- end container -->\n<\/div><!-- end root -->\n\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-3&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h3 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-3-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-3\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\"><a href=\"\/\/cbgfjbdckbpenliighcjcbjfiihnnkfe\/#yjlzxxs02\">\u7b2c\u4e8c\u7ae0\uff1a\u65bd\u5de5\u4ea4\u4ed8\u4e0e\u9a8c\u8bc1<\/a><\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h3>\n\n\n\n<div inert aria-labelledby=\"accordion-item-3\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-3-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2176","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2176\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2176\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-06T07:26:57+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2176\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2176\",\"name\":\"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-05T10:21:05+00:00\",\"dateModified\":\"2026-06-06T07:26:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2176#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2176\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2176#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u9f99\u8109\u6696\u901a\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2176","og_locale":"zh_CN","og_type":"article","og_title":"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_url":"https:\/\/longmai-nt.com\/?page_id=2176","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-06T07:26:57+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2176","url":"https:\/\/longmai-nt.com\/?page_id=2176","name":"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-05T10:21:05+00:00","dateModified":"2026-06-06T07:26:57+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2176#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2176"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2176#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4e91\u749f\u6797\u8457X\u5148\u751f\u7a7a\u8c03\u65b0\u98ce\u6863\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u9f99\u8109\u6696\u901a","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"http:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2176"}],"version-history":[{"count":11,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2176\/revisions"}],"predecessor-version":[{"id":2273,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2176\/revisions\/2273"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}