{"id":2324,"date":"2026-06-06T19:05:20","date_gmt":"2026-06-06T11:05:20","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2324"},"modified":"2026-09-26T18:49:09","modified_gmt":"2026-09-26T10:49:09","slug":"%e4%bc%9f%e6%98%9fpe-rt-ii-%e4%ba%8c%e4%bb%a3%e5%9c%b0%e6%9a%96%e7%ae%a1%e9%be%99%e8%84%89%e6%9a%96%e9%80%9a%e6%b7%b1%e5%ba%a6%e8%a7%a3%e8%af%bb%e7%89%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2324","title":{"rendered":"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248"},"content":{"rendered":"\n<!-- \u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1 \u00b7 \u6df1\u5ea6\u89e3\u8bfb\uff08\u5185\u5bb9\u5757\uff0c\u76f4\u63a5\u7c98 WP \u6587\u7ae0\u7f16\u8f91\u5668\u6b63\u6587\u533a\uff0c\u52ff\u7c98 <head>\uff09 -->\n<!--\nSEO \u6807\u9898\uff08\u226428 \u6c49\u5b57\uff09\uff1a\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1\u00b7\u9f99\u8109\u6df1\u5ea6\u89e3\u8bfb\nMeta \u63cf\u8ff0\uff1a\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1\u6df1\u5ea6\u89e3\u8bfb\uff1aII \u578b\u6599\u3001\u8010\u6e29 85\u2103\/\u77ac\u65f6 110\u2103\u3001\u627f\u538b 1.6MPa\u3001\u5bff\u547d 75 \u5e74+\u3001EVOH \u963b\u6c27\u3002\u4e00\u4ee3 vs \u4e8c\u4ee3\u5168\u9762\u5bf9\u6bd4\uff0c\u96c6\u4e2d\u4f9b\u6696\/\u6563\u70ed\u5668\u6539\u5730\u6696\u600e\u4e48\u9009\u3002\n\u7126\u70b9\u5173\u952e\u8bcd\uff1a\u4f1f\u661f PE-RT II \u5730\u6696\u7ba1,\u4f1f\u661f\u4e8c\u4ee3\u5730\u6696\u7ba1,\u4f1f\u661f\u5730\u6696\u7ba1\u600e\u4e48\u6837,PE-RT II \u578b\u7ba1,\u5730\u6696\u7ba1\u4e00\u4ee3\u4e8c\u4ee3\u533a\u522b,\u963b\u6c27\u5730\u6696\u7ba1,\u4f1f\u661f\u7ba1\u4e1a,\u5730\u6696\u7ba1\u5bff\u547d\n\u53d1\u5e03\u6ce8\u610f\uff1a\n1. \u5168\u6587 h1=0\uff08\u6587\u7ae0\u6807\u9898\u5373\u552f\u4e00 h1\uff09\uff1b\n2. \u4e24\u5f20\u4ea7\u54c1\u5b9e\u62cd\u56fe\u5df2\u62bd\u6210\u672c\u5730\u6587\u4ef6 weixing-pert2-photo-1.jpg \/ -2.jpg\uff0c\u4e0a\u4f20\u5a92\u4f53\u5e93\u540e\u628a\u4e0b\u9762\u4e24\u5904 REPLACE \u5360\u4f4d\u6362\u6210\u771f\u5b9e\u5a92\u4f53 URL\uff1b\n3. FAQ JSON-LD \u8d70 WPCode\uff08\u89c1\u540c\u540d _FAQ_JSONLD_WPCode.txt\uff09\uff0c\u7528 is_page(2324) \u6761\u4ef6\u6ce8\u5165\uff1b\n4. \u5730\u6696\u4e13\u5c5e\u5185\u94fe\u7684 XXXX \u5360\u4f4d\u6362\u6210\u771f\u5b9e page_id\uff08\u7ad9\u70b9\u5730\u56fe page 3023 \u53ef\u67e5\uff09\u3002\n-->\n\n<!-- \u9762\u5305\u5c51 -->\n<p style=\"font-size:.85rem;color:#888;margin:0 0 14px;\">\u60a8\u7684\u4f4d\u7f6e\uff1a<a href=\"https:\/\/longmai-nt.com\/\" style=\"color:#1a6fc4;text-decoration:none;\">\u9996\u9875<\/a> &gt; <a href=\"https:\/\/longmai-nt.com\/?page_id=XXXX\u5730\u6696\u7cfb\u7edf\" style=\"color:#1a6fc4;text-decoration:none;\">\u5730\u6696\u7cfb\u7edf<\/a> &gt; \u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1<\/p>\n\n<!-- \u82f1\u96c4\u680f\uff08\u6df1\u8272\u80cc\u666f\u767d\u5b57\uff0c4 \u5c42 !important \u4fdd\u62a4\uff09 -->\n<div style=\"background:linear-gradient(135deg,#12314F 0%,#1c4470 100%);color:#fff!important;padding:36px 28px;border-radius:14px;margin-bottom:26px;\">\n  <p style=\"color:#E8541E!important;font-weight:700;letter-spacing:2px;margin:0 0 8px;\">NEW GENERATION \u00b7 \u4e8c\u4ee3\u5347\u7ea7<\/p>\n  <h2 style=\"color:#fff!important;font-size:1.7rem;line-height:1.4;margin:0 0 12px;\">\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1 \u00b7 \u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb<\/h2>\n  <p style=\"color:#fff!important;font-size:1.05rem;line-height:1.85;margin:0;\">\u91c7\u7528 II \u578b\u8010\u70ed\u805a\u4e59\u70ef\u539f\u6599\uff0c\u5168\u9762\u63d0\u5347\u8010\u70ed\u3001\u6297\u538b\u4e0e\u6297\u5212\u4f24\u6027\u80fd\uff0c\u4e3a\u9ad8\u7aef\u91c7\u6696\u7cfb\u7edf\u63d0\u4f9b\u66f4\u7a33\u5b9a\u53ef\u9760\u7684\u7ba1\u9053\u65b9\u6848\u3002\u9f99\u8109\u6696\u901a\u4e3a\u4f1f\u661f\u7ba1\u4e1a\u6388\u6743\u7ecf\u9500\u5546\uff0c\u4e13\u6ce8\u9ad8\u54c1\u8d28\u5730\u6696\u7cfb\u7edf\u96c6\u6210\u4e0e\u670d\u52a1\u3002<\/p>\n<\/div>\n\n<!-- \u6838\u5fc3\u53c2\u6570\u5fbd\u7ae0 -->\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;margin:0 0 28px;\">\n  <div style=\"flex:1 1 130px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:14px;text-align:center;\"><div style=\"font-size:1.5rem;font-weight:800;color:#12314F;\">75\u5e74+<\/div><div style=\"font-size:.85rem;color:#555;\">\u8d85\u957f\u8bbe\u8ba1\u5bff\u547d<\/div><\/div>\n  <div style=\"flex:1 1 130px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:14px;text-align:center;\"><div style=\"font-size:1.5rem;font-weight:800;color:#12314F;\">110\u2103<\/div><div style=\"font-size:.85rem;color:#555;\">\u77ac\u65f6\u8010\u6e29\u4e0a\u9650<\/div><\/div>\n  <div style=\"flex:1 1 130px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:14px;text-align:center;\"><div style=\"font-size:1.5rem;font-weight:800;color:#12314F;\">1.6MPa<\/div><div style=\"font-size:.85rem;color:#555;\">\u516c\u79f0\u627f\u538b<\/div><\/div>\n  <div style=\"flex:1 1 130px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:14px;text-align:center;\"><div style=\"font-size:1.5rem;font-weight:800;color:#12314F;\">\u73e0\u5149\u7d2b<\/div><div style=\"font-size:.85rem;color:#555;\">\u5dee\u5f02\u5316\u7ba1\u4f53<\/div><\/div>\n<\/div>\n\n<h2 style=\"margin-top:8px;color:#12314F;\">\u4e00\u3001\u54c1\u724c\u80cc\u4e66\uff1a\u4f1f\u661f\u7ba1\u4e1a<\/h2>\n<p style=\"line-height:1.9;\">\u6d59\u6c5f\u4f1f\u661f\u65b0\u578b\u5efa\u6750\u80a1\u4efd\u6709\u9650\u516c\u53f8\uff08\u4f1f\u661f\u65b0\u6750\uff09\u521b\u5efa\u4e8e 1999 \u5e74\uff0c\u7cfb\u4e2d\u56fd\u6c11\u8425\u4f01\u4e1a 500 \u5f3a\u4f1f\u661f\u96c6\u56e2\u63a7\u80a1\u5b50\u516c\u53f8\uff0c2010 \u5e74\u6df1\u4ea4\u6240\u4e0a\u5e02\uff08\u80a1\u7968\u4ee3\u7801 002372\uff09\u3002\u5168\u7403\u4e03\u5927\u751f\u4ea7\u57fa\u5730\u300150+ \u5206\u516c\u53f8\u300130000+ \u8425\u9500\u7f51\u70b9\uff0c\u4e3b\u7f16\/\u53c2\u7f16\u56fd\u5bb6\u548c\u884c\u4e1a\u6807\u51c6 260+ \u9879\uff0c\u62e5\u6709\u4e13\u5229 800+ \u9879\uff0c\u8363\u83b7\u6d59\u6c5f\u7701\u653f\u5e9c\u8d28\u91cf\u5956\u3001\u56fd\u5bb6\u77e5\u8bc6\u4ea7\u6743\u793a\u8303\u4f01\u4e1a\u3001\u56fd\u5bb6\u4f01\u4e1a\u6280\u672f\u4e2d\u5fc3\u7b49\u591a\u9879\u8363\u8a89\u3002<\/p>\n<p style=\"background:#eef6ee;border-left:4px solid #2e7d32;padding:10px 14px;margin:14px 0;line-height:1.8;\">\u4ea7\u54c1\u6210\u529f\u5e94\u7528\u4e8e\u9e1f\u5de2\u3001\u6c34\u7acb\u65b9\u3001\u6e2f\u73e0\u6fb3\u5927\u6865\u3001\u5317\u4eac\u5927\u5174\u56fd\u9645\u673a\u573a\u7b49\u56fd\u5bb6\u8d85\u7ea7\u5de5\u7a0b\uff0c\u4ee5\u5353\u8d8a\u54c1\u8d28\u5b88\u62a4\u91cd\u5927\u57fa\u7840\u8bbe\u65bd\u5efa\u8bbe\u3002\u9f99\u8109\u6696\u901a\u4e3a\u4f1f\u661f\u7ba1\u4e1a\u6388\u6743\u7ecf\u9500\u5546\uff0c\u4e13\u6ce8\u9ad8\u54c1\u8d28\u5730\u6696\u7cfb\u7edf\u96c6\u6210\u4e0e\u670d\u52a1\u3002<\/p>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u4e8c\u3001\u516d\u5927\u6838\u5fc3\u4f18\u52bf<\/h2>\n<p style=\"line-height:1.9;\">\u4ece\u539f\u6599\u5230\u5de5\u827a\uff0c\u6bcf\u4e00\u4e2a\u73af\u8282\u90fd\u4e3a\u60a8\u7cbe\u5fc3\u8003\u91cf\uff1a<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:12px 0;font-size:.95rem;\">\n  <thead><tr style=\"background:#12314F;color:#fff!important;\"><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u4f18\u52bf<\/th><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u8868\u73b0<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u8d85\u957f\u5bff\u547d<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u5de5\u4f5c\u6e29\u5ea6 70\u2103\u3001\u538b\u529b 0.8MPa \u6761\u4ef6\u4e0b\uff0c\u8bbe\u8ba1\u4f7f\u7528\u5bff\u547d 75 \u5e74\u4ee5\u4e0a\uff0c\u8fdc\u8d85\u4e00\u4ee3\u7684 50 \u5e74<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u65e0\u60e7\u9ad8\u6e29<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u6b63\u5e38\u4f7f\u7528 -20\u2103~85\u2103\uff0c\u77ac\u65f6\u8010\u6e29\u53ef\u8fbe 110\u2103\uff0c\u53ef\u95f4\u6b47\u627f\u53d7 95\u2103 \u9ad8\u6e29<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u66f4\u9ad8\u627f\u538b<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u516c\u79f0\u538b\u529b 1.6MPa\uff0c\u8f83\u4e00\u4ee3\u63d0\u5347 28%\uff0c\u7cfb\u7edf\u8fd0\u884c\u66f4\u53ef\u9760<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u6781\u5bd2\u4ece\u5bb9<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u6781\u9650\u4f4e\u6e29\u8106\u88c2\u4f4e\u81f3 -70\u2103\uff0c\u8f83\u4e00\u4ee3\u964d\u4f4e 20\u2103\uff0c\u51ac\u5b63\u65bd\u5de5\u4e0e\u8fd0\u8f93\u66f4\u5b89\u5168<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u8010\u5212\u4f24<\/td><td style=\"border:1px solid #ccc;padding:8px;\">II \u578b\u539f\u6599\u5bc6\u5ea6\u66f4\u9ad8\u3001\u8868\u9762\u786c\u5ea6\u663e\u8457\u63d0\u5347\uff0c\u62b5\u5fa1\u8fd0\u8f93\u4e0e\u65bd\u5de5\u5916\u529b\u5212\u4f24<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u5bbd\u6e29\u57df\u9002\u914d<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-20\u2103~85\u2103 \u5bbd\u5e45\u6e29\u5ea6\u8303\u56f4\uff0c\u9002\u914d\u96c6\u4e2d\u4f9b\u6696\u538b\u529b\u4e0d\u7a33\u3001\u6563\u70ed\u5668\u6539\u5730\u6696\u7b49\u590d\u6742\u5de5\u51b5<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u4e09\u3001\u4ea7\u54c1\u5b9e\u62cd \u00b7 \u73e0\u5149\u7d2b\u7ba1\u4f53<\/h2>\n<p style=\"line-height:1.9;\">\u4e8c\u4ee3\u7ba1\u91c7\u7528\u8fdb\u53e3 II \u578b\u8010\u70ed\u805a\u4e59\u70ef\uff08PE-RT II\uff09\u539f\u6599\uff0c\u73e0\u5149\u7d2b\u7ba1\u4f53\u5e02\u573a\u8fa8\u8bc6\u5ea6\u9ad8\uff1b\u53e3\u5f84 dn20mm\u3001\u58c1\u539a 2.0mm\u3001\u516c\u79f0\u538b\u529b 1.6MPa\uff0c\u53ef\u4f7f\u7528\u540c\u6750\u8d28\u7ba1\u4ef6\u70ed\u7194\u8fde\u63a5\uff0c\u67d4\u97e7\u6027\u4f18\u826f\u3001\u65bd\u5de5\u4fbf\u6377\uff0c\u7b26\u5408\u56fd\u6807 GB\/T 28799.2 \u5168\u90e8\u8981\u6c42\u3002<\/p>\n<div style=\"display:flex;flex-wrap:wrap;gap:14px;margin:14px 0;justify-content:center;\">\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-1.jpg\" alt=\"\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1 \u73e0\u5149\u7d2b\u7ba1\u4f53\u5b9e\u62cd\" style=\"flex:0 0 auto;width:auto;max-width:260px;height:auto;border-radius:10px;border:1px solid #e3e3e3;\">\n  <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-2.jpg\" alt=\"\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1 \u65bd\u5de5\u4e0e\u7ba1\u4ef6\u5b9e\u62cd\" style=\"flex:0 0 auto;width:auto;max-width:320px;height:auto;border-radius:10px;border:1px solid #e3e3e3;\">\n<\/div>\n<p style=\"font-size:.85rem;color:#888;\">\uff08\u4e0a\u56fe\u4e3a\u4ea7\u54c1\u5b9e\u62cd\uff0c\u539f\u56fe\u5df2\u62bd\u6210\u672c\u5730\u6587\u4ef6 weixing-pert2-photo-1\/-2.jpg\uff0c\u4e0a\u4f20\u5a92\u4f53\u5e93\u540e\u66ff\u6362\u4e0a\u65b9\u5360\u4f4d\u94fe\u63a5\u5373\u53ef\u3002\uff09<\/p>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u56db\u3001\u6280\u672f\u53c2\u6570<\/h2>\n<table style=\"width:100%;border-collapse:collapse;margin:12px 0;font-size:.95rem;\">\n  <thead><tr style=\"background:#12314F;color:#fff!important;\"><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u53c2\u6570\u9879<\/th><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u89c4\u683c\u6307\u6807<\/th><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u8bf4\u660e<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u4ea7\u54c1\u578b\u53f7<\/td><td style=\"border:1px solid #ccc;padding:8px;\">PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1<\/td><td style=\"border:1px solid #ccc;padding:8px;\">II \u578b\u8010\u70ed\u805a\u4e59\u70ef\u539f\u6599<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;\">\u7ba1\u4f53\u989c\u8272<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u73e0\u5149\u7d2b<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u5dee\u5f02\u5316\u8fa8\u8bc6\uff0c\u4fbf\u4e8e\u533a\u5206\u7cfb\u7edf<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u516c\u79f0\u53e3\u5f84<\/td><td style=\"border:1px solid #ccc;padding:8px;\">dn20mm<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u6807\u51c6\u5730\u6696\u7ba1\u5f84<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;\">\u58c1\u539a<\/td><td style=\"border:1px solid #ccc;padding:8px;\">2.0mm<\/td><td style=\"border:1px solid #ccc;padding:8px;\">S5 \u7cfb\u5217\u6807\u51c6\u58c1\u539a<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u516c\u79f0\u538b\u529b<\/td><td style=\"border:1px solid #ccc;padding:8px;\">1.6 MPa<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u8f83\u4e00\u4ee3\u63d0\u5347 28%<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;\">\u4f7f\u7528\u6e29\u5ea6<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-20\u2103 ~ 85\u2103\uff08\u6b63\u5e38\u5de5\u51b5\uff09<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u5bbd\u6e29\u57df\u9002\u914d<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u77ac\u65f6\u8010\u6e29<\/td><td style=\"border:1px solid #ccc;padding:8px;\">110\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u6781\u7aef\u5de5\u51b5\u4f59\u91cf<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;\">\u95f4\u6b47\u4f7f\u7528\u6e29\u5ea6<\/td><td style=\"border:1px solid #ccc;padding:8px;\">95\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u9ad8\u6e29\u95f4\u6b47\u8fd0\u884c<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u6781\u9650\u4f4e\u6e29\u8106\u88c2<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-70\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u6781\u5bd2\u8fd0\u8f93\u65bd\u5de5\u4fdd\u969c<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;\">\u8bbe\u8ba1\u5bff\u547d<\/td><td style=\"border:1px solid #ccc;padding:8px;\">75 \u5e74\u4ee5\u4e0a\uff0870\u2103\/0.8MPa\uff09<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u957f\u671f\u7a33\u5b9a\u8fd0\u884c<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u8fde\u63a5\u65b9\u5f0f<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u540c\u6750\u8d28\u70ed\u7194\u8fde\u63a5<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u8fde\u63a5\u53ef\u9760\u3001\u7ef4\u4fee\u65b9\u4fbf<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;\">\u5bfc\u70ed\u7cfb\u6570<\/td><td style=\"border:1px solid #ccc;padding:8px;\">0.4 W\/(m\u00b7K)<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u9ad8\u6548\u5bfc\u70ed\u3001\u5feb\u901f\u5347\u6e29<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;\">\u963b\u6c27\u6027\u80fd<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u22640.1 g\/(m\u00b3\u00b7d)<\/td><td style=\"border:1px solid #ccc;padding:8px;\">EVOH \u963b\u6c27\u5c42<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u4e94\u3001\u4e00\u4ee3 vs \u4e8c\u4ee3 \u00b7 \u5168\u9762\u5347\u7ea7<\/h2>\n<table style=\"width:100%;border-collapse:collapse;margin:12px 0;font-size:.95rem;\">\n  <thead><tr style=\"background:#12314F;color:#fff!important;\"><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u5bf9\u6bd4\u9879<\/th><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u4f1f\u661f PE-RT I \u4e00\u4ee3<\/th><th style=\"border:1px solid #ccc;padding:8px;text-align:left;color:#fff!important;\">\u4f1f\u661f PE-RT II \u4e8c\u4ee3<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u539f\u6599\u7b49\u7ea7<\/td><td style=\"border:1px solid #ccc;padding:8px;\">I \u578b\u6599<\/td><td style=\"border:1px solid #ccc;padding:8px;\">II \u578b\u6599<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u6e29\u5ea6\u8303\u56f4<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-20\u2103 ~ 70\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-20\u2103 ~ 85\u2103<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u77ac\u65f6\u8010\u6e29<\/td><td style=\"border:1px solid #ccc;padding:8px;\">95\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">110\u2103<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u516c\u79f0\u538b\u529b<\/td><td style=\"border:1px solid #ccc;padding:8px;\">1.25 MPa<\/td><td style=\"border:1px solid #ccc;padding:8px;\">1.6 MPa\uff08+28%\uff09<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">45\u2103 \u5de5\u4f5c\u538b\u529b<\/td><td style=\"border:1px solid #ccc;padding:8px;\">0.79 MPa<\/td><td style=\"border:1px solid #ccc;padding:8px;\">0.98 MPa<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">60\u2103 \u5de5\u4f5c\u538b\u529b<\/td><td style=\"border:1px solid #ccc;padding:8px;\">0.67 MPa<\/td><td style=\"border:1px solid #ccc;padding:8px;\">0.83 MPa<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u6781\u9650\u4f4e\u6e29<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-50\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">-70\u2103<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u8bbe\u8ba1\u5bff\u547d<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u7ea6 50 \u5e74<\/td><td style=\"border:1px solid #ccc;padding:8px;\">75 \u5e74+<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u8868\u9762\u786c\u5ea6<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u6807\u51c6<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u663e\u8457\u63d0\u5347<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u957f\u671f\u8010\u6e29<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u226460\u2103<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u226480\u2103<\/td><\/tr>\n    <tr><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u9002\u7528\u5de5\u51b5<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u58c1\u6302\u7089\/\u7a7a\u6c14\u80fd\uff08\u6c34\u6e29\u226455\u2103\uff09<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\/\u6563\u70ed\u5668\u6539\u5730\u6696<\/td><\/tr>\n    <tr style=\"background:#f6f8fb;\"><td style=\"border:1px solid #ccc;padding:8px;font-weight:700;\">\u963b\u6c27\u6027\u80fd<\/td><td style=\"border:1px solid #ccc;padding:8px;\">\u666e\u901a\uff08\u65e0 EVOH \u963b\u6c27\u5c42\uff09<\/td><td style=\"border:1px solid #ccc;padding:8px;\">EVOH \u963b\u6c27 \u22640.1 g\/(m\u00b3\u00b7d)<\/td><\/tr>\n  <\/tbody>\n<\/table>\n<p style=\"background:#fff4ec;border-left:4px solid #E8541E;padding:10px 14px;margin:14px 0;line-height:1.8;\">\u8fdb\u4e00\u6b65\u9605\u8bfb\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=XXXX\u5730\u6696\u7ba1\u9009\u578b\" style=\"color:#1a6fc4;text-decoration:none;font-weight:700;\">\u5730\u6696\u7ba1\u9009\u578b\u5fc5\u8bfb \u2014 PE-RT I \u578b vs II \u578b\u5b8c\u5168\u5bf9\u6bd4<\/a><\/p>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u516d\u3001\u9002\u7528\u573a\u666f<\/h2>\n<p style=\"line-height:1.9;\">\u4e8c\u4ee3\u4ea7\u54c1\u5c24\u5176\u5efa\u8bae\u4ee5\u4e0b\u573a\u666f\u4f18\u5148\u9009\u7528\uff1a<\/p>\n<ul style=\"line-height:2;\">\n  <li><strong>\u96c6\u4e2d\u4f9b\u6696\u5c0f\u533a<\/strong>\uff1a\u538b\u529b\u4e0e\u6e29\u5ea6\u6ce2\u52a8\u8f83\u5927\uff0c\u5efa\u8bae\u9009\u7528\u4e8c\u4ee3\u7ba1\u4ee5\u83b7\u5f97\u66f4\u9ad8\u5b89\u5168\u5197\u4f59\uff1b<\/li>\n  <li><strong>\u6563\u70ed\u5668\u6539\u5730\u6696<\/strong>\uff1a\u8bbe\u8ba1\u6e29\u5ea6\u504f\u9ad8\u7684\u6539\u9020\u9879\u76ee\uff0c\u63a8\u8350\u4e8c\u4ee3\u7ba1\u5e94\u5bf9\u9ad8\u6e29\u5de5\u51b5\uff1b<\/li>\n  <li><strong>\u9ad8\u5c42\u4f4f\u5b85\u91c7\u6696<\/strong>\uff1a\u9ad8\u5c42\u6c34\u538b\u6ce2\u52a8\u5927\uff0c\u4e8c\u4ee3\u7ba1\u66f4\u5f3a\u627f\u538b\u80fd\u529b\u4fdd\u969c\u7cfb\u7edf\u7a33\u5b9a\uff1b<\/li>\n  <li><strong>\u72ec\u7acb\u91c7\u6696\u7cfb\u7edf<\/strong>\uff1a\u8ffd\u6c42\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\u7684\u5bb6\u5ead\u7528\u6237\uff0c\u5efa\u8bae\u9009\u7528\u4ee5\u83b7\u5f97 75 \u5e74+ \u4f7f\u7528\u5bff\u547d\uff1b<\/li>\n  <li><strong>\u9ad8\u7aef\u5546\u4e1a\u9879\u76ee<\/strong>\uff1a\u529e\u516c\u697c\u3001\u9152\u5e97\u7b49\u5546\u4e1a\u7a7a\u95f4\uff0c\u5bf9\u7ba1\u9053\u54c1\u8d28\u548c\u5bff\u547d\u8981\u6c42\u66f4\u9ad8\u3002<\/li>\n<\/ul>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u4e03\u3001\u54c1\u8d28\u4fdd\u969c\u4e0e\u5b89\u88c5\u5efa\u8bae<\/h2>\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;margin:14px 0;\">\n  <div style=\"flex:1 1 120px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:12px;text-align:center;\"><div style=\"font-size:1.3rem;font-weight:800;color:#12314F;\">75+ \u5e74<\/div><div style=\"font-size:.8rem;color:#555;\">\u8bbe\u8ba1\u5bff\u547d<\/div><\/div>\n  <div style=\"flex:1 1 120px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:12px;text-align:center;\"><div style=\"font-size:1.3rem;font-weight:800;color:#12314F;\">1.6 MPa<\/div><div style=\"font-size:.8rem;color:#555;\">\u516c\u79f0\u538b\u529b<\/div><\/div>\n  <div style=\"flex:1 1 120px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:12px;text-align:center;\"><div style=\"font-size:1.3rem;font-weight:800;color:#12314F;\">110\u2103<\/div><div style=\"font-size:.8rem;color:#555;\">\u77ac\u65f6\u8010\u6e29<\/div><\/div>\n  <div style=\"flex:1 1 120px;background:#f6f8fb;border:1px solid #e3e3e3;border-radius:10px;padding:12px;text-align:center;\"><div style=\"font-size:1.3rem;font-weight:800;color:#12314F;\">-70\u2103<\/div><div style=\"font-size:.8rem;color:#555;\">\u6781\u9650\u4f4e\u6e29<\/div><\/div>\n<\/div>\n<p style=\"background:#fff8e1;border-left:4px solid #f0a500;padding:10px 14px;margin:14px 0;line-height:1.8;\">\u26a0\ufe0f \u5b89\u88c5\u5efa\u8bae\uff1a\u5efa\u8bae\u7531\u4e13\u4e1a\u6696\u901a\u65bd\u5de5\u56e2\u961f\u8fdb\u884c\u5b89\u88c5\u4f5c\u4e1a\uff0c\u65bd\u5de5\u524d\u8bf7\u5ba1\u614e\u8bc4\u4f30\u7ba1\u9053\u6577\u8bbe\u65b9\u6848\u3002\u7ba1\u9053\u5b58\u50a8\u5e94\u907f\u514d\u957f\u65f6\u95f4\u9633\u5149\u76f4\u5c04\uff0c\u8fd0\u8f93\u8fc7\u7a0b\u4e2d\u6ce8\u610f\u9632\u6b62\u5c16\u9510\u7269\u4f53\u5212\u4f24\u7ba1\u58c1\u3002\u5177\u4f53\u65bd\u5de5\u89c4\u8303\u8bf7\u53c2\u8003\u4ea7\u54c1\u9644\u5e26\u6280\u672f\u624b\u518c\u3002<\/p>\n\n<h2 style=\"margin-top:28px;color:#12314F;\">\u516b\u3001\u5e38\u89c1\u95ee\u9898\uff08AI \u641c\u7d22\u53ef\u76f4\u63a5\u5f15\u7528\uff09<\/h2>\n<dl style=\"line-height:1.85;\">\n  <dt style=\"font-weight:700;margin-top:10px;color:#12314F;\">\u4f1f\u661f PE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1\u600e\u4e48\u6837\uff1f<\/dt>\n  <dd style=\"margin:0 0 8px;\">\u4e8c\u4ee3\u91c7\u7528 II \u578b\u8010\u70ed\u805a\u4e59\u70ef\u539f\u6599\uff0c\u6b63\u5e38\u4f7f\u7528\u6e29\u5ea6 -20\u2103~85\u2103\u3001\u77ac\u65f6\u8010\u6e29 110\u2103\uff0c\u516c\u79f0\u538b\u529b 1.6MPa\uff08\u8f83\u4e00\u4ee3 +28%\uff09\uff0c\u8bbe\u8ba1\u5bff\u547d 75 \u5e74\u4ee5\u4e0a\uff0c\u5e76\u5e26 EVOH \u963b\u6c27\u5c42\uff0c\u8f83\u4e00\u4ee3\u5728\u8010\u70ed\u3001\u627f\u538b\u3001\u5bff\u547d\u3001\u963b\u6c27\u4e0a\u5168\u9762\u5347\u7ea7\u3002<\/dd>\n  <dt style=\"font-weight:700;margin-top:10px;color:#12314F;\">\u4f1f\u661f PE-RT I \u548c II \u4ee3\u6709\u4ec0\u4e48\u533a\u522b\uff1f<\/dt>\n  <dd style=\"margin:0 0 8px;\">\u6838\u5fc3\u5dee\u5f02\uff1a\u539f\u6599 I \u578b vs II \u578b\uff1b\u8010\u6e29 70\u2103\u219285\u2103\u3001\u77ac\u65f6 95\u2103\u2192110\u2103\uff1b\u627f\u538b 1.25\u21921.6MPa\uff1b\u8bbe\u8ba1\u5bff\u547d 50\u219275 \u5e74\uff1b\u4e00\u4ee3\u65e0\u963b\u6c27\u5c42\u3001\u4e8c\u4ee3\u5e26 EVOH \u963b\u6c27\uff1b\u4e8c\u4ee3\u66f4\u9002\u914d\u96c6\u4e2d\u4f9b\u6696\u3001\u6563\u70ed\u5668\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u5de5\u51b5\u3002<\/dd>\n  <dt style=\"font-weight:700;margin-top:10px;color:#12314F;\">\u4f1f\u661f PE-RT II \u5730\u6696\u7ba1\u6709\u963b\u6c27\u5c42\u5417\uff1f<\/dt>\n  <dd style=\"margin:0 0 8px;\">\u6709\u3002\u4e8c\u4ee3\u5e26 EVOH \u963b\u6c27\u5c42\uff0c\u900f\u6c27\u7387 \u22640.1 g\/(m\u00b3\u00b7d)\uff0c\u53ef\u963b\u6b62\u6c27\u6c14\u6e17\u5165\u7cfb\u7edf\u3001\u51cf\u7f13\u91d1\u5c5e\u90e8\u4ef6\u6c27\u5316\u8150\u8680\uff1b\u4e00\u4ee3\u4e3a\u666e\u901a\u7ba1\uff0c\u65e0 EVOH \u963b\u6c27\u5c42\u3002<\/dd>\n  <dt style=\"font-weight:700;margin-top:10px;color:#12314F;\">\u4f1f\u661f\u5730\u6696\u7ba1\u80fd\u7528\u591a\u5c11\u5e74\uff1f<\/dt>\n  <dd style=\"margin:0 0 8px;\">\u4e8c\u4ee3\u8bbe\u8ba1\u4f7f\u7528\u5bff\u547d 75 \u5e74\u4ee5\u4e0a\uff08\u6d4b\u8bd5\u6761\u4ef6 70\u2103\/0.8MPa\uff09\uff1b\u4e00\u4ee3\u7ea6 50 \u5e74\u3002\u5b9e\u9645\u5bff\u547d\u4e0e\u5de5\u51b5\u3001\u65bd\u5de5\u8d28\u91cf\u76f8\u5173\u3002<\/dd>\n  <dt style=\"font-weight:700;margin-top:10px;color:#12314F;\">\u6210\u90fd\u96c6\u4e2d\u4f9b\u6696\u5c0f\u533a\u7528\u51e0\u4ee3\u4f1f\u661f\u7ba1\uff1f<\/dt>\n  <dd style=\"margin:0 0 8px;\">\u96c6\u4e2d\u4f9b\u6696\u538b\u529b\u4e0e\u6e29\u5ea6\u6ce2\u52a8\u8f83\u5927\uff0c\u5efa\u8bae\u9009\u4e8c\u4ee3\u4ee5\u83b7\u5f97\u66f4\u9ad8\u5b89\u5168\u5197\u4f59\uff1b\u6563\u70ed\u5668\u6539\u5730\u6696\uff08\u8bbe\u8ba1\u6e29\u5ea6\u504f\u9ad8\uff09\u4e5f\u63a8\u8350\u4e8c\u4ee3\u5e94\u5bf9\u9ad8\u6e29\u5de5\u51b5\u3002<\/dd>\n  <dt style=\"font-weight:700;margin-top:10px;color:#12314F;\">\u4f1f\u661f PE-RT II \u5730\u6696\u7ba1\u6210\u90fd\u54ea\u91cc\u4e70\u3001\u8c01\u5b89\u88c5\uff1f<\/dt>\n  <dd style=\"margin:0 0 8px;\">\u9f99\u8109\u6696\u901a\u4e3a\u4f1f\u661f\u7ba1\u4e1a\u6388\u6743\u7ecf\u9500\u5546\uff0c\u53cc\u95e8\u5e97\u5b9e\u4f53\u7ecf\u8425\uff08\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97\u3001\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97\uff09\uff0c\u63d0\u4f9b\u5730\u6696\u7cfb\u7edf\u96c6\u6210\u8bbe\u8ba1\u3001\u4e13\u4e1a\u65bd\u5de5\u4e0e\u552e\u540e\u4fdd\u969c\u3002\u8be6\u89c1\u4e0b\u65b9\u95e8\u5e97\u4fe1\u606f\u3002<\/dd>\n<\/dl>\n\n<!-- ==================== \u76f8\u5173\u9605\u8bfb\uff08GEO \u5185\u94fe\uff09 ==================== -->\n<h2 style=\"margin-top:28px;color:#12314F;\">\u76f8\u5173\u9605\u8bfb<\/h2>\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;margin:14px 0;\">\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=XXXX\u5730\u6696\u7ba1\u9009\u578b\" style=\"display:block;flex:1 1 220px;border:1px solid #e3e3e3;border-left:4px solid #E8541E;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u5730\u6696\u7ba1\u9009\u578b\u5fc5\u8bfb\uff1aPE-RT I \u578b vs II \u578b\u5b8c\u5168\u5bf9\u6bd4<\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=XXXX\u5730\u6696\u7cfb\u7edf\u65b9\u6848\" style=\"display:block;flex:1 1 220px;border:1px solid #e3e3e3;border-left:4px solid #E8541E;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u5730\u6696\u7cfb\u7edf\u65b9\u6848\u5168\u4e66 \u00b7 \u5b9e\u6218\u6307\u5357<\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=XXXX\u5730\u6696\u6848\u4f8b\" style=\"display:block;flex:1 1 220px;border:1px solid #e3e3e3;border-left:4px solid #E8541E;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u771f\u5b9e\u5ba2\u6237\u6863\u6848 \u00b7 \u6210\u90fd\u5730\u6696\u6848\u4f8b\u53c2\u8003<\/a>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=XXXX\u5730\u6696\u4ef7\u683c\" style=\"display:block;flex:1 1 220px;border:1px solid #e3e3e3;border-left:4px solid #E8541E;border-radius:10px;padding:12px 14px;text-decoration:none;color:#1a1a1a;font-weight:700;\">\u6210\u90fd\u5730\u6696\u4ef7\u683c \u00b7 \u542b\u7ba1\u6750\u4e0e\u5b89\u88c5\u9884\u7b97<\/a>\n<\/div>\n\n<!-- ==================== \u95e8\u5e97\u4e0e\u670d\u52a1\uff08\u53cc\u95e8\u5e97\uff0c\u52ff\u6302\u552e\u540e\u4e13\u7ebf\uff09 ==================== -->\n<h2 style=\"margin-top:28px;color:#12314F;\">\u95e8\u5e97\u4e0e\u670d\u52a1<\/h2>\n<p style=\"background:#eef6ee;border-left:4px solid #2e7d32;padding:10px 14px;margin:14px 0;line-height:1.85;\">\u9f99\u8109\u6696\u901a \u00b7 2004 \u5e74\u8d77\u6210\u90fd\u672c\u5730\u6696\u901a\u670d\u52a1\u5546\uff0c\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u94bb\u77f3\u6388\u6743\u670d\u52a1\u5546\uff0c\u53cc\u95e8\u5e97\u5b9e\u4f53\u7ecf\u8425\u3002\u670d\u52a1\u627f\u8bfa\uff1a\u5148\u68c0\u6d4b\u540e\u62a5\u4ef7\uff0c\u5f00\u5de5\u524d\u786e\u8ba4\u603b\u4ef7\uff1b\u68c0\u6d4b\u8d39\u7ef4\u4fee\u53ef\u62b5\u6263\uff0c\u4e0d\u7ef4\u4fee\u624d\u6536\uff1b\u4fee\u4e0d\u597d\u4e0d\u6536\u8d39\uff0c\u540c\u6b3e\u6545\u969c\u514d\u8d39\u8fd4\u4fee\uff1b\u539f\u5382\u914d\u4ef6\uff0c\u660e\u7801\u6807\u4ef7\u4e0d\u641e\u9690\u5f62\u52a0\u4ef7\u3002<\/p>\n<div style=\"display:flex;flex-wrap:wrap;gap:14px;margin:14px 0;\">\n  <div style=\"flex:1 1 280px;border:1px solid #e3e3e3;border-radius:10px;padding:14px;\">\n    <div style=\"font-weight:800;color:#12314F;margin-bottom:6px;\">\u5357\u5bcc\u68ee\u00b7\u9ad8\u65b0\u5e97<\/div>\n    <div style=\"font-size:.92rem;line-height:1.8;color:#333;\">\u9ad8\u65b0\u533a\u90fd\u4f1a\u8def 99 \u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 3 \u697c A348<br>\u70ed\u7ebf 028-86131795<\/div>\n  <\/div>\n  <div style=\"flex:1 1 280px;border:1px solid #e3e3e3;border-radius:10px;padding:14px;\">\n    <div style=\"font-weight:800;color:#12314F;margin-bottom:6px;\">\u5317\u5bcc\u68ee\u00b7\u6210\u534e\u5e97<\/div>\n    <div style=\"font-size:.92rem;line-height:1.8;color:#333;\">\u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986 A \u5e62 5 \u697c A5135 \u53f7<br>\u70ed\u7ebf 028-65272586<\/div>\n  <\/div>\n<\/div>\n<p style=\"font-size:.85rem;color:#888;margin-top:10px;\">\u670d\u52a1\u8303\u56f4\uff1a\u6210\u90fd\u5168\u57df\u3002\u4ea7\u54c1\u6280\u672f\u53c2\u6570\u57fa\u4e8e PE-RT II \u578b\u8010\u70ed\u805a\u4e59\u70ef\u539f\u6599\u5b9e\u6d4b\u6570\u636e\uff0c\u7b26\u5408 GB\/T 28799.2 \u56fd\u5bb6\u6807\u51c6\uff1b\u672c\u9875\u6570\u636e\u4ec5\u4f9b\u53c2\u8003\uff0c\u5b9e\u9645\u6027\u80fd\u56e0\u4f7f\u7528\u73af\u5883\u4e0e\u5de5\u51b5\u4e0d\u540c\u53ef\u80fd\u6709\u6240\u5dee\u5f02\uff0c\u5efa\u8bae\u6309\u9879\u76ee\u9700\u6c42\u5ba1\u614e\u9009\u62e9\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u60a8\u7684\u4f4d\u7f6e\uff1a\u9996\u9875 &gt; \u5730\u6696\u7cfb\u7edf &#038;g [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2324","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u4f1f\u661fPE-RT II\u4ee3\u5730\u6696\u7ba1\uff0cII\u578b\u539f\u6599\u5168\u9762\u5347\u7ea7\uff1a\u8010\u6e2985\u2103\u3001\u627f\u538b1.6MPa\u3001\u5bff\u547d75\u5e74\uff0c\u6781\u9650\u4f4e\u6e29-70\u2103\u3002\u9002\u7528\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\u3001\u6696\u6c14\u7247\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u573a\u666f\u3002\u5b54\u96c0\u84dd\u3001\u73e0\u5149\u7d2b\u7ba1\u4f53\u7b49\u4e09\u79cd\u989c\u8272\u53ef\u9009\uff0cEVOH\u963b\u6c27\u5c42\u53ef\u9009\u3002\u9f99\u8109\u6696\u901a\u6388\u6743\u7ecf\u9500\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2324\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u4f1f\u661fPE-RT II\u4ee3\u5730\u6696\u7ba1\uff0cII\u578b\u539f\u6599\u5168\u9762\u5347\u7ea7\uff1a\u8010\u6e2985\u2103\u3001\u627f\u538b1.6MPa\u3001\u5bff\u547d75\u5e74\uff0c\u6781\u9650\u4f4e\u6e29-70\u2103\u3002\u9002\u7528\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\u3001\u6696\u6c14\u7247\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u573a\u666f\u3002\u5b54\u96c0\u84dd\u3001\u73e0\u5149\u7d2b\u7ba1\u4f53\u7b49\u4e09\u79cd\u989c\u8272\u53ef\u9009\uff0cEVOH\u963b\u6c27\u5c42\u53ef\u9009\u3002\u9f99\u8109\u6696\u901a\u6388\u6743\u7ecf\u9500\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2324\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-26T10:49:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-1.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324\",\"name\":\"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/weixing-pert2-photo-1.jpg\",\"datePublished\":\"2026-06-06T11:05:20+00:00\",\"dateModified\":\"2026-09-26T10:49:09+00:00\",\"description\":\"\u4f1f\u661fPE-RT II\u4ee3\u5730\u6696\u7ba1\uff0cII\u578b\u539f\u6599\u5168\u9762\u5347\u7ea7\uff1a\u8010\u6e2985\u2103\u3001\u627f\u538b1.6MPa\u3001\u5bff\u547d75\u5e74\uff0c\u6781\u9650\u4f4e\u6e29-70\u2103\u3002\u9002\u7528\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\u3001\u6696\u6c14\u7247\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u573a\u666f\u3002\u5b54\u96c0\u84dd\u3001\u73e0\u5149\u7d2b\u7ba1\u4f53\u7b49\u4e09\u79cd\u989c\u8272\u53ef\u9009\uff0cEVOH\u963b\u6c27\u5c42\u53ef\u9009\u3002\u9f99\u8109\u6696\u901a\u6388\u6743\u7ecf\u9500\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/weixing-pert2-photo-1.jpg\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/weixing-pert2-photo-1.jpg\",\"width\":380,\"height\":570},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2324#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248 - \u9f99\u8109\u6696\u901a","description":"\u4f1f\u661fPE-RT II\u4ee3\u5730\u6696\u7ba1\uff0cII\u578b\u539f\u6599\u5168\u9762\u5347\u7ea7\uff1a\u8010\u6e2985\u2103\u3001\u627f\u538b1.6MPa\u3001\u5bff\u547d75\u5e74\uff0c\u6781\u9650\u4f4e\u6e29-70\u2103\u3002\u9002\u7528\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\u3001\u6696\u6c14\u7247\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u573a\u666f\u3002\u5b54\u96c0\u84dd\u3001\u73e0\u5149\u7d2b\u7ba1\u4f53\u7b49\u4e09\u79cd\u989c\u8272\u53ef\u9009\uff0cEVOH\u963b\u6c27\u5c42\u53ef\u9009\u3002\u9f99\u8109\u6696\u901a\u6388\u6743\u7ecf\u9500\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2324","og_locale":"zh_CN","og_type":"article","og_title":"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248 - \u9f99\u8109\u6696\u901a","og_description":"\u4f1f\u661fPE-RT II\u4ee3\u5730\u6696\u7ba1\uff0cII\u578b\u539f\u6599\u5168\u9762\u5347\u7ea7\uff1a\u8010\u6e2985\u2103\u3001\u627f\u538b1.6MPa\u3001\u5bff\u547d75\u5e74\uff0c\u6781\u9650\u4f4e\u6e29-70\u2103\u3002\u9002\u7528\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\u3001\u6696\u6c14\u7247\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u573a\u666f\u3002\u5b54\u96c0\u84dd\u3001\u73e0\u5149\u7d2b\u7ba1\u4f53\u7b49\u4e09\u79cd\u989c\u8272\u53ef\u9009\uff0cEVOH\u963b\u6c27\u5c42\u53ef\u9009\u3002\u9f99\u8109\u6696\u901a\u6388\u6743\u7ecf\u9500\u3002","og_url":"https:\/\/longmai-nt.com\/?page_id=2324","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-09-26T10:49:09+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-1.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2324","url":"https:\/\/longmai-nt.com\/?page_id=2324","name":"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=2324#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=2324#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-1.jpg","datePublished":"2026-06-06T11:05:20+00:00","dateModified":"2026-09-26T10:49:09+00:00","description":"\u4f1f\u661fPE-RT II\u4ee3\u5730\u6696\u7ba1\uff0cII\u578b\u539f\u6599\u5168\u9762\u5347\u7ea7\uff1a\u8010\u6e2985\u2103\u3001\u627f\u538b1.6MPa\u3001\u5bff\u547d75\u5e74\uff0c\u6781\u9650\u4f4e\u6e29-70\u2103\u3002\u9002\u7528\u96c6\u4e2d\u4f9b\u6696\u6539\u9020\u3001\u6696\u6c14\u7247\u6539\u5730\u6696\u7b49\u9ad8\u6e29\u9ad8\u538b\u573a\u666f\u3002\u5b54\u96c0\u84dd\u3001\u73e0\u5149\u7d2b\u7ba1\u4f53\u7b49\u4e09\u79cd\u989c\u8272\u53ef\u9009\uff0cEVOH\u963b\u6c27\u5c42\u53ef\u9009\u3002\u9f99\u8109\u6696\u901a\u6388\u6743\u7ecf\u9500\u3002","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2324#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2324"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=2324#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-1.jpg","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/09\/weixing-pert2-photo-1.jpg","width":380,"height":570},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2324#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u4f1f\u661fPE-RT II \u4e8c\u4ee3\u5730\u6696\u7ba1~\u9f99\u8109\u6696\u901a\u6df1\u5ea6\u89e3\u8bfb\u7248"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2324"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2324\/revisions"}],"predecessor-version":[{"id":13216,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2324\/revisions\/13216"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}