{"id":2378,"date":"2026-06-07T01:41:18","date_gmt":"2026-06-06T17:41:18","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2378"},"modified":"2026-10-09T22:30:11","modified_gmt":"2026-10-09T14:30:11","slug":"%e5%be%b7%e5%9b%bd%e8%bf%aa%e8%af%ba%ef%bc%88dianorm%ef%bc%89%e9%92%a2%e5%88%b6%e6%9d%bf%e5%bc%8f%e6%9a%96%e6%b0%94%e7%89%87","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2378","title":{"rendered":"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09"},"content":{"rendered":"\n<style>\n\/* ===== \u6837\u5f0f\u9694\u79bb\uff1a\u6240\u6709\u6837\u5f0f\u9650\u5b9a\u5728 .purmo-page \u5185 ===== *\/\n.purmo-page {\n    max-width: 1024px;\n    margin: 0 auto;\n    padding: 20px;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", \"PingFang SC\", \"Hiragino Sans GB\", \"Microsoft YaHei\", sans-serif;\n    color: #333;\n    line-height: 1.8;\n    box-sizing: border-box;\n    font-size: 16px;\n    background: #fffbeb;\n}\n\n.purmo-page * {\n    box-sizing: border-box;\n}\n\n\/* \u5bfc\u822a\u76ee\u5f55 - \u684c\u9762\u7aef\u53f3\u4fa7\u60ac\u6d6e *\/\n.purmo-page .toc-nav {\n    position: sticky;\n    top: 20px;\n    float: right;\n    width: 200px;\n    margin-left: 24px;\n    margin-bottom: 24px;\n    background: #fff;\n    border: 1px solid #fde68a;\n    border-radius: 8px;\n    padding: 16px;\n    font-size: 14px;\n}\n.purmo-page .toc-nav h3 {\n    margin: 0 0 12px 0;\n    font-size: 15px;\n    color: #92400e;\n    border-bottom: 2px solid #f59e0b;\n    padding-bottom: 8px;\n}\n.purmo-page .toc-nav a {\n    display: block;\n    padding: 4px 0;\n    color: #78716c;\n    text-decoration: none;\n    border-bottom: 1px solid #fef3c7;\n}\n.purmo-page .toc-nav a:hover {\n    color: #d97706;\n}\n\n.purmo-page .hero-title {\n    font-size: 28px;\n    color: #78350f;\n    border-bottom: 3px solid #f59e0b;\n    padding-bottom: 12px;\n    margin-bottom: 24px;\n    clear: both;\n}\n\/* \u4e3atoc\u817e\u51fa\u7a7a\u95f4 *\/\n.purmo-page .hero-title,\n.purmo-page .product-hero + h2,\n.purmo-page .product-hero + h2,\n.purmo-page > h2:first-of-type {\n    clear: both;\n}\n\n.purmo-page h2 {\n    font-size: 22px;\n    color: #92400e;\n    margin-top: 40px;\n    margin-bottom: 16px;\n    padding-left: 12px;\n    border-left: 4px solid #f59e0b;\n    clear: both;\n}\n\n.purmo-page h3 {\n    font-size: 18px;\n    color: #b45309;\n    margin-top: 24px;\n    margin-bottom: 12px;\n}\n\n.purmo-page p {\n    margin-bottom: 16px;\n    text-align: justify;\n}\n\n.purmo-page table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0;\n    font-size: 15px;\n}\n\n.purmo-page table th,\n.purmo-page table td {\n    border: 1px solid #fde68a;\n    padding: 10px 14px;\n    text-align: left;\n}\n\n.purmo-page table th {\n    background: #f59e0b;\n    font-weight: 600;\n    color: #fff;\n}\n\n.purmo-page table tr:nth-child(even) {\n    background: #fffbeb;\n}\n\n.purmo-page img {\n    max-width: 100%;\n    height: auto;\n    display: block;\n    margin: 20px auto;\n    border-radius: 6px;\n}\n\n.purmo-page .product-hero {\n    background: linear-gradient(135deg, #f59e0b 0%, #d97706 50%, #b45309 100%);\n    color: white;\n    padding: 48px 32px;\n    border-radius: 8px;\n    margin-bottom: 32px;\n    text-align: center;\n}\n\n.purmo-page .product-hero .hero-title {\n    color: white;\n    border: none;\n    font-size: 32px;\n    margin-bottom: 12px;\n}\n\n.purmo-page .product-hero .subtitle {\n    font-size: 18px;\n    opacity: 0.95;\n    margin-bottom: 8px;\n}\n\n.purmo-page .product-hero .tag {\n    display: inline-block;\n    background: rgba(255,255,255,0.2);\n    padding: 4px 16px;\n    border-radius: 20px;\n    margin: 4px;\n    font-size: 14px;\n}\n\n\/* \u6e05\u9664\u6d6e\u52a8 - \u5728toc\u540e *\/\n.purmo-page .clearfix::after {\n    content: \"\";\n    display: table;\n    clear: both;\n}\n\n.purmo-page .spec-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n    gap: 16px;\n    margin: 24px 0;\n}\n\n.purmo-page .spec-card {\n    background: #fff;\n    border-left: 3px solid #f59e0b;\n    padding: 16px;\n    border-radius: 4px;\n    box-shadow: 0 1px 3px rgba(245,158,11,0.15);\n}\n\n.purmo-page .spec-card .label {\n    font-size: 13px;\n    color: #a8a29e;\n    margin-bottom: 4px;\n}\n\n.purmo-page .spec-card .value {\n    font-size: 18px;\n    font-weight: 600;\n    color: #92400e;\n}\n\n.purmo-page .feature-list {\n    list-style: none;\n    padding: 0;\n}\n\n.purmo-page .feature-list li {\n    padding: 10px 0 10px 28px;\n    position: relative;\n    border-bottom: 1px solid #fef3c7;\n}\n\n.purmo-page .feature-list li:before {\n    content: \"\u2713\";\n    position: absolute;\n    left: 0;\n    color: #16a34a;\n    font-weight: bold;\n    font-size: 16px;\n}\n\n.purmo-page .comparison-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 24px 0;\n}\n\n.purmo-page .comparison-table th {\n    background: #92400e;\n    color: white;\n    padding: 12px;\n}\n\n.purmo-page .highlight-box {\n    background: #fef9c3;\n    border-left: 4px solid #f59e0b;\n    padding: 16px 20px;\n    margin: 24px 0;\n    border-radius: 0 4px 4px 0;\n}\n\n.purmo-page .cta-button {\n    display: inline-block;\n    background: #f59e0b;\n    color: white;\n    padding: 12px 32px;\n    border-radius: 4px;\n    text-decoration: none;\n    font-weight: 600;\n    margin: 8px 8px 8px 0;\n    transition: background 0.2s;\n}\n\n.purmo-page .cta-button:hover {\n    background: #d97706;\n}\n\n.purmo-page .cta-button.blue {\n    background: #0891b2;\n}\n.purmo-page .cta-button.blue:hover {\n    background: #0e7490;\n}\n\n.purmo-page .model-table {\n    font-size: 14px;\n}\n\n.purmo-page .model-table th {\n    background: #b45309;\n    color: white;\n}\n\n.purmo-page .tip-box {\n    background: #dcfce7;\n    border-left: 4px solid #22c55e;\n    padding: 12px 16px;\n    margin: 16px 0;\n    border-radius: 0 4px 4px 0;\n    font-size: 14px;\n}\n\n.purmo-page .warning-box {\n    background: #fef3c7;\n    border-left: 4px solid #f59e0b;\n    padding: 12px 16px;\n    margin: 16px 0;\n    border-radius: 0 4px 4px 0;\n    font-size: 14px;\n}\n\n.purmo-page .product-img-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n    gap: 16px;\n    margin: 24px 0;\n}\n\n.purmo-page .product-img-grid .img-card {\n    background: #fff;\n    border-radius: 8px;\n    overflow: hidden;\n    box-shadow: 0 2px 8px rgba(0,0,0,0.08);\n    text-align: center;\n}\n\n.purmo-page .product-img-grid .img-card p {\n    padding: 8px;\n    font-size: 14px;\n    color: #78716c;\n    margin: 0;\n}\n\n\/* \u79fb\u52a8\u7aef\u9002\u914d *\/\n@media (max-width: 739px) {\n    .purmo-page {\n        padding: 12px;\n        font-size: 15px;\n    }\n    .purmo-page .hero-title { font-size: 24px; }\n    .purmo-page h2 { font-size: 19px; }\n    .purmo-page .product-hero { padding: 32px 16px; }\n    .purmo-page .product-hero .hero-title { font-size: 26px; }\n    .purmo-page .spec-grid { grid-template-columns: 1fr; }\n    .purmo-page table { font-size: 13px; }\n    .purmo-page table th,\n    .purmo-page table td { padding: 8px 10px; }\n    .purmo-page .toc-nav { display: none; }\n    .purmo-page .product-img-grid { grid-template-columns: 1fr; }\n}\n<\/style>\n\n<div class=\"purmo-page\">\n\n<div class=\"product-hero\">\n    <div class=\"hero-title\">\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08\u82ac\u5170\u54c1\u724c \u00b7 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09<\/div>\n    <p class=\"subtitle\">\u82ac\u5170 PURMO \u54c1\u724c \u00b7 \u5fb7\u56fd DiaNorm \u540c\u6b3e \u00b7 \u4e2d\u56fd\u626c\u5dde\u5236\u9020 \u00b7 EN 442 \u6b27\u6d32\u6807\u51c6<\/p>\n    <div>\n        <span class=\"tag\">\u626c\u5dde\u5de5\u5382\u5236\u9020<\/span>\n        <span class=\"tag\">EN442\u6b27\u6d32\u6807\u51c6<\/span>\n        <span class=\"tag\">\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed<\/span>\n        <span class=\"tag\">\u5341\u5927\u54c1\u724c\u63a8\u8350<\/span>\n    <\/div>\n<\/div>\n\n<div style=\"margin:22px 0;padding:18px 20px;background:#fffbeb;border:1px solid #fcd34d;border-left:5px solid #f59e0b;border-radius:8px;\">\n  <p style=\"margin:0 0 10px 0;font-size:16px;font-weight:700;color:#92400e;\">\u54c1\u724c\u8bf4\u660e \u00b7 \u5173\u4e8e\u300c\u73bb\u739b PURMO\u300d\u4e0e\u300c\u8fea\u8bfa DiaNorm\u300d<\/p>\n  <p style=\"margin:0 0 10px 0;font-size:15px;color:#4b5563;line-height:1.75;\">\n    \u73bb\u739b\uff08<strong>PURMO<\/strong>\uff09\u662f<strong>\u82ac\u5170\u54c1\u724c<\/strong>\uff0c1953 \u5e74\u8bde\u751f\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff1b\u8fea\u8bfa\uff08<strong>DiaNorm<\/strong>\uff09\u662f<strong>\u5fb7\u56fd\u54c1\u724c<\/strong>\uff0c\n    \u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821\uff08Vienenburg\uff09\u3002\u4e24\u8005<strong>\u540c\u5c5e Purmo \u96c6\u56e2<\/strong>\uff08\u539f\u745e\u7279\u683c Rettig ICC \u96c6\u56e2\uff0c2019 \u5e74\u96c6\u56e2\u7edf\u4e00\u66f4\u540d\u4e3a Purmo \u96c6\u56e2\uff09\u3002\n  <\/p>\n  <p style=\"margin:0 0 10px 0;font-size:15px;color:#4b5563;line-height:1.75;\">\n    \u4e24\u4e2a\u54c1\u724c\u662f<strong style=\"color:#92400e;\">\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d<\/strong>\u2014\u2014\u540c\u4e00\u6761\u626c\u5dde\u751f\u4ea7\u7ebf\u3001\u540c\u4e00\u5957 EN 442 \u5236\u9020\u6807\u51c6\u3001\n    \u540c\u4e00\u7ec4\u578b\u53f7\u89c4\u683c\u4e0e\u6280\u672f\u53c2\u6570\uff0c\u4ec5\u54c1\u724c\u6807\u8bc6\u4e0d\u540c\u3002\n  <\/p>\n  <p style=\"margin:0 0 14px 0;font-size:15px;color:#4b5563;line-height:1.75;\">\n    <strong>\u5bf9\u9009\u578b\u6ca1\u6709\u5f71\u54cd\uff1a<\/strong>\u9009\u73bb\u739b\u6216\u9009\u8fea\u8bfa\uff0c\u4ea7\u54c1\u672c\u8eab\u5b8c\u5168\u4e00\u6837\u2014\u2014\u540c\u578b\u53f7\u3001\u540c\u53c2\u6570\u3001\u540c\u8d28\u4fdd\u3002\n    \u60a8\u53ea\u9700\u6309\u623f\u95f4\u70ed\u8d1f\u8377\u9009\u578b\u53f7\u4e0e\u5c3a\u5bf8\uff1b\u8ba2\u8d27\u5408\u540c\u4e0a\u6807\u6ce8\u54ea\u4e2a\u54c1\u724c\u540d\uff0c\u4ea4\u4ed8\u7684\u5c31\u662f\u540c\u4e00\u6b3e\u4ea7\u54c1\u3002\n  <\/p>\n  <table style=\"margin:0;font-size:14px;background:#fff;\">\n    <thead><tr><th style=\"width:26%;\">\u9879\u76ee<\/th><th>\u73bb\u739b PURMO<\/th><th>\u8fea\u8bfa DiaNorm<\/th><\/tr><\/thead>\n    <tbody>\n      <tr><td><strong>\u54c1\u724c\u540d<\/strong><\/td><td>\u73bb\u739b PURMO<\/td><td>\u8fea\u8bfa DiaNorm<\/td><\/tr>\n      <tr><td><strong>\u54c1\u724c\u6765\u6e90<\/strong><\/td><td><strong>\u82ac\u5170<\/strong>\uff081953 \u5e74\u521b\u7acb\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff09<\/td><td><strong>\u5fb7\u56fd<\/strong>\uff08\u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821 Vienenburg\uff09<\/td><\/tr>\n      <tr><td><strong>\u6240\u5c5e\u96c6\u56e2<\/strong><\/td><td>Purmo \u96c6\u56e2\uff08\u539f\u745e\u7279\u683c Rettig ICC\uff09<\/td><td>\u540c\u4e00\u96c6\u56e2<\/td><\/tr>\n      <tr><td><strong>\u751f\u4ea7\u57fa\u5730<\/strong><\/td><td>\u4e2d\u56fd\u6c5f\u82cf\u626c\u5dde\u5de5\u5382<\/td><td>\u540c\u4e00\u6761\u751f\u4ea7\u7ebf<\/td><\/tr>\n      <tr><td><strong>\u5236\u9020\u6807\u51c6<\/strong><\/td><td>EN 442 \/ DIN 55900<\/td><td>\u76f8\u540c<\/td><\/tr>\n      <tr><td><strong>\u578b\u53f7\u7cfb\u5217<\/strong><\/td><td>DNCV \u7cfb\u5217<\/td><td>\u76f8\u540c<\/td><\/tr>\n      <tr><td><strong>\u6280\u672f\u53c2\u6570<\/strong><\/td><td>\u5b8c\u5168\u4e00\u81f4<\/td><td>\u5b8c\u5168\u4e00\u81f4<\/td><\/tr>\n      <tr><td><strong>\u8d28\u4fdd\u653f\u7b56<\/strong><\/td><td>10 \u5e74<\/td><td>\u76f8\u540c<\/td><\/tr>\n      <tr><td><strong>\u4e24\u8005\u5173\u7cfb<\/strong><\/td><td colspan=\"2\"><strong>\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d\uff0c\u53ef\u4e92\u6362<\/strong>\uff08\u884c\u4e1a\u79f0\"\u5e73\u66ff\"\uff09<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <p style=\"margin:14px 0 0 0;font-size:15px;color:#4b5563;line-height:1.75;\">\n    <strong>\u4ea7\u5730\u8bf4\u660e\uff08\u5982\u5b9e\u544a\u77e5\uff09\uff1a<\/strong>\u672c\u9875\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u4ea7\u81ea\u96c6\u56e2\u4f4d\u4e8e<strong>\u6c5f\u82cf\u626c\u5dde<\/strong>\u7684\u81ea\u6709\u5de5\u5382\u2014\u2014\n    \u8be5\u5de5\u5382\u662f Purmo \u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382\uff0c\u4e5f\u662f\u96c6\u56e2<strong>\u5728\u6b27\u6d32\u4ee5\u5916\u7684\u552f\u4e00\u751f\u4ea7\u57fa\u5730<\/strong>\uff0c2019 \u5e74 9 \u6708\u6295\u4ea7\uff0c\n    \u6309\u6b27\u6d32 <strong>EN 442<\/strong> \u6807\u51c6\u5236\u9020\u3002<strong>\u54c1\u724c\u6e90\u81ea\u6b27\u6d32\uff0c\u5de5\u5382\u5728\u626c\u5dde<\/strong>\uff0c\u4e24\u53e5\u8bdd\u90fd\u6210\u7acb\u3002\n  <\/p>\n  <p style=\"margin:10px 0 0 0;font-size:14px;color:#78716c;line-height:1.7;\">\n    <strong>\u4e00\u53e5\u8bdd\u7406\u6e05\u54c1\u724c\u6765\u6e90\uff1a<\/strong>\u73bb\u739b PURMO \u662f<strong>\u82ac\u5170<\/strong>\u54c1\u724c\uff0c\u8fea\u8bfa DiaNorm \u662f<strong>\u5fb7\u56fd<\/strong>\u54c1\u724c\u2014\u2014\n    \u4e24\u4e2a\u54c1\u724c\u5404\u6709\u81ea\u5df1\u7684\u6765\u6e90\u56fd\uff0c\u90fd\u5c5e\u4e8e Purmo \u96c6\u56e2\uff1b\u672c\u9875\u4ea7\u54c1\u5728\u4e2d\u56fd\u626c\u5dde\u5de5\u5382\u5236\u9020\uff0c<strong>\u4e0d\u662f\u8fdb\u53e3\u4ea7\u54c1<\/strong>\u3002\n  <\/p>\n<\/div>\n\n<div style=\"text-align:center; margin:24px 0;\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-18-1024x763.png\" alt=\"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08\u82ac\u5170\u54c1\u724c \u00b7 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09\" style=\"max-width:100%;height:auto;border-radius:8px;box-shadow:0 4px 16px rgba(0,0,0,0.1);\">\n<\/div>\n\n<div class=\"toc-nav\">\n    <h3>\ud83d\udcd1 \u76ee\u5f55\u5bfc\u822a<\/h3>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#gaishu\">\u4e00\u3001\u4ea7\u54c1\u6982\u8ff0<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#jiegou\">\u4e8c\u3001\u7ed3\u6784\u539f\u7406<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#xinghao\">\u4e09\u3001\u578b\u53f7\u89c4\u683c<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#canhuo\">\u56db\u3001\u6280\u672f\u53c2\u6570<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#duibi\">\u4e94\u3001\u7ade\u54c1\u5bf9\u6bd4<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#anzhuang\">\u516d\u3001\u5b89\u88c5\u8981\u70b9<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#xuanxing\">\u4e03\u3001\u9009\u578b\u6307\u5357<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#chanpin\">\u516b\u3001\u4ea7\u54c1\u56fe\u518c<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#lianjie\">\u4e5d\u3001\u914d\u5957\u65b9\u6848<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2378#faq\">\u5341\u3001\u5e38\u89c1\u95ee\u9898<\/a>\n<\/div>\n\n<div class=\"clearfix\"><\/div>\n\n<h2 id=\"gaishu\">\u4e00\u3001\u4ea7\u54c1\u6982\u8ff0<\/h2>\n<p>\u73bb\u739b\uff08<strong>PURMO<\/strong>\uff09\u662f<strong>\u82ac\u5170\u54c1\u724c<\/strong>\uff0c1953 \u5e74\u8bde\u751f\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff1b\u8fea\u8bfa\uff08DiaNorm\uff09\u662f<strong>\u5fb7\u56fd\u54c1\u724c<\/strong>\uff0c\u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821\uff08Vienenburg\uff09\u3002\u4e8c\u8005\u540c\u5c5e\u6b27\u6d32 <strong>Purmo \u96c6\u56e2<\/strong>\uff08\u539f\u745e\u7279\u683c Rettig \u96c6\u56e2\uff0c2019 \u5e74\u96c6\u56e2\u7edf\u4e00\u66f4\u540d\u4e3a Purmo \u96c6\u56e2\uff09\uff0c\u662f\u6b27\u6d32\u9886\u5148\u7684\u94a2\u5236\u677f\u5f0f\u6563\u70ed\u5668\u54c1\u724c\u4f53\u7cfb\u3002\u8fea\u8bfa\u4e0e\u73bb\u739b\u662f<strong>\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d<\/strong>\u2014\u2014\u540c\u4e00\u6761\u751f\u4ea7\u7ebf\u3001\u540c\u4e00\u5957 EN 442 \u6807\u51c6\u3001\u540c\u4e00\u7ec4\u578b\u53f7\u89c4\u683c\u4e0e\u6280\u672f\u53c2\u6570\uff0c\u4ec5\u54c1\u724c\u6807\u8bc6\u4e0d\u540c\u3002\u4e2d\u56fd\u5e02\u573a\u4e0a\u9500\u552e\u7684\u4e24\u4e2a\u54c1\u724c\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u5747\u4ea7\u81ea\u96c6\u56e2\u4f4d\u4e8e<strong>\u6c5f\u82cf\u626c\u5dde<\/strong>\u7684\u81ea\u6709\u5de5\u5382\u2014\u2014\u8be5\u5de5\u5382\u662f Purmo \u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382\uff0c\u4e5f\u662f\u96c6\u56e2\u5728\u6b27\u6d32\u4ee5\u5916\u7684\u552f\u4e00\u751f\u4ea7\u57fa\u5730\u3002<\/p>\n\n<p>\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6563\u70ed\u5668\u91c7\u7528<strong>\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed<\/strong>\u6a21\u5f0f\uff0c\u677f\u5f0f\u7ed3\u6784\u914d\u5408\u5185\u90e8\u5bf9\u6d41\u7fc5\u7247\uff0c\u5b9e\u73b0\u201d20%\u8f90\u5c04+80%\u5bf9\u6d41\u201d\u7684\u9ad8\u6548\u4f20\u70ed\uff0c\u662f\u6b27\u6d32\u5bb6\u5ead\u91c7\u6696\u7684\u4e3b\u6d41\u9009\u62e9\u3002<\/p>\n\n<p>\u4f5c\u4e3a<a href=\"https:\/\/longmai-nt.com\/?page_id=2137\" target=\"_blank\" style=\"color:#d97706;\">\u6696\u6c14\u7247\u7cfb\u7edf\u805a\u5408\u9875<\/a>\u91cd\u70b9\u63a8\u8350\u7684\u54c1\u724c\uff0c\u73bb\u739b\u5728\u6210\u90fd\u5e02\u573a\u7531\u9f99\u8109\u6696\u901a\u4ee3\u7406\uff0c\u4ea7\u54c1\u7531\u96c6\u56e2\u626c\u5dde\u5de5\u5382\u751f\u4ea7\u76f4\u4f9b\uff0c\u63d0\u4f9b<strong>10\u5e74\u5b98\u65b9\u8d28\u4fdd<\/strong>\u3002<\/p>\n\n<div class=\"spec-grid\">\n    <div class=\"spec-card\">\n        <div class=\"label\">\u5236\u9020\u6807\u51c6<\/div>\n        <div class=\"value\">EN442<\/div>\n    <\/div>\n    <div class=\"spec-card\">\n        <div class=\"label\">\u6750\u8d28<\/div>\n        <div class=\"value\">EN 10130 \u51b7\u8f67\u4f4e\u78b3\u94a2<\/div>\n    <\/div>\n    <div class=\"spec-card\">\n        <div class=\"label\">\u5de5\u4f5c\u538b\u529b<\/div>\n        <div class=\"value\">\u226410 bar<\/div>\n    <\/div>\n    <div class=\"spec-card\">\n        <div class=\"label\">\u6807\u51c6\u5de5\u51b5<\/div>\n        <div class=\"value\">95\u2103\/70\u2103\/20\u2103<\/div>\n    <\/div>\n    <div class=\"spec-card\">\n        <div class=\"label\">\u63a5\u53e3\u5c3a\u5bf8<\/div>\n        <div class=\"value\">G1\/2\u2033 \/ G3\/4\u2033<\/div>\n    <\/div>\n    <div class=\"spec-card\">\n        <div class=\"label\">\u8868\u9762\u5904\u7406<\/div>\n        <div class=\"value\">\u73af\u6c27\u7c89\u672b\u9759\u7535\u55b7\u6d82<\/div>\n    <\/div>\n<\/div>\n\n<h2 id=\"jiegou\">\u4e8c\u3001\u7ed3\u6784\u539f\u7406<\/h2>\n<p>\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u7531<strong>\u8d70\u6c34\u90e8\u5206<\/strong>\u548c<strong>\u5bf9\u6d41\u7247<\/strong>\u4e24\u90e8\u5206\u7ec4\u6210\uff1a<\/p>\n<ul class=\"feature-list\">\n    <li><strong>\u8d70\u6c34\u90e8\u5206<\/strong>\uff1a\u4e24\u7247\u6eda\u538b\u6210\u578b\u7684\u94a2\u677f\u7ecf\u7535\u963b\u710a\u63a5\u800c\u6210\uff0c\u5185\u90e8\u5f62\u6210\u6c34\u6d41\u901a\u9053<\/li>\n    <li><strong>\u5bf9\u6d41\u7247<\/strong>\uff1a\u710a\u63a5\u5728\u4e24\u5757\u94a2\u677f\u4e4b\u95f4\u7684\u5bf9\u6d41\u7fc5\u7247\uff0c\u5927\u5e45\u589e\u52a0\u6563\u70ed\u9762\u79ef<\/li>\n    <li><strong>\u8fde\u63a5\u65b9\u5f0f<\/strong>\uff1a\u4fa7\u8fdb\u4fa7\u51fa\uff08\u6807\u51c6\uff09\u3001\u5e95\u8fdb\u5e95\u51fa\uff08\u53ef\u9009\uff09<\/li>\n    <li><strong>\u710a\u63a5\u5de5\u827a<\/strong>\uff1a\u5168\u81ea\u52a8\u7535\u963b\u710a\uff0c\u710a\u70b9\u5c11\u3001\u5f3a\u5ea6\u9ad8\u3001\u6f0f\u6c34\u98ce\u9669\u6781\u4f4e<\/li>\n<\/ul>\n\n<div style=\"text-align:center; margin:32px 0;\">\n<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 680 340\" width=\"680\" height=\"340\" style=\"max-width:100%;background:#fffbeb;border-radius:8px;padding:16px;border:1px solid #fde68a;\">\n\n  <text x=\"340\" y=\"28\" text-anchor=\"middle\" font-size=\"16\" font-weight=\"bold\" fill=\"#92400e\">\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u7ed3\u6784\u793a\u610f\u56fe<\/text>\n\n  <rect x=\"140\" y=\"70\" width=\"400\" height=\"180\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"2\" rx=\"4\"><\/rect>\n\n  <g fill=\"none\" stroke=\"#d97706\" stroke-width=\"1.5\" opacity=\"0.7\">\n    <line x1=\"165\" y1=\"85\" x2=\"165\" y2=\"235\"><\/line>\n    <line x1=\"190\" y1=\"85\" x2=\"190\" y2=\"235\"><\/line>\n    <line x1=\"215\" y1=\"85\" x2=\"215\" y2=\"235\"><\/line>\n    <line x1=\"240\" y1=\"85\" x2=\"240\" y2=\"235\"><\/line>\n    <line x1=\"265\" y1=\"85\" x2=\"265\" y2=\"235\"><\/line>\n    <line x1=\"290\" y1=\"85\" x2=\"290\" y2=\"235\"><\/line>\n    <line x1=\"315\" y1=\"85\" x2=\"315\" y2=\"235\"><\/line>\n    <line x1=\"340\" y1=\"85\" x2=\"340\" y2=\"235\"><\/line>\n    <line x1=\"365\" y1=\"85\" x2=\"365\" y2=\"235\"><\/line>\n    <line x1=\"390\" y1=\"85\" x2=\"390\" y2=\"235\"><\/line>\n    <line x1=\"415\" y1=\"85\" x2=\"415\" y2=\"235\"><\/line>\n    <line x1=\"440\" y1=\"85\" x2=\"440\" y2=\"235\"><\/line>\n    <line x1=\"465\" y1=\"85\" x2=\"465\" y2=\"235\"><\/line>\n    <line x1=\"490\" y1=\"85\" x2=\"490\" y2=\"235\"><\/line>\n  <\/g>\n\n  <rect x=\"140\" y=\"70\" width=\"400\" height=\"12\" fill=\"#f59e0b\" opacity=\"0.4\"><\/rect>\n  <rect x=\"140\" y=\"238\" width=\"400\" height=\"12\" fill=\"#f59e0b\" opacity=\"0.4\"><\/rect>\n\n  <circle cx=\"120\" cy=\"120\" r=\"8\" fill=\"#dc2626\"><\/circle>\n  <text x=\"120\" y=\"155\" text-anchor=\"middle\" font-size=\"12\" fill=\"#dc2626\">\u8fdb\u6c34<\/text>\n  <line x1=\"120\" y1=\"128\" x2=\"140\" y2=\"128\" stroke=\"#dc2626\" stroke-width=\"2\"><\/line>\n\n  <circle cx=\"120\" cy=\"200\" r=\"8\" fill=\"#0891b2\"><\/circle>\n  <text x=\"120\" y=\"230\" text-anchor=\"middle\" font-size=\"12\" fill=\"#0891b2\">\u56de\u6c34<\/text>\n  <line x1=\"120\" y1=\"192\" x2=\"140\" y2=\"192\" stroke=\"#0891b2\" stroke-width=\"2\"><\/line>\n\n  <text x=\"340\" y=\"320\" text-anchor=\"middle\" font-size=\"13\" fill=\"#b45309\">\u25b2 \u8868\u9762\u8f90\u5c04\u6563\u70ed\uff08\u7ea620%\uff09<\/text>\n\n  <text x=\"55\" y=\"105\" font-size=\"12\" fill=\"#16a34a\" transform=\"rotate(-90 55 105)\">\u5bf9\u6d41\u6c14\u6d41\u2191<\/text>\n  <text x=\"55\" y=\"225\" font-size=\"12\" fill=\"#16a34a\" transform=\"rotate(-90 55 225)\">\u5bf9\u6d41\u6c14\u6d41\u2191<\/text>\n\n  <rect x=\"530\" y=\"80\" width=\"140\" height=\"120\" fill=\"white\" stroke=\"#fde68a\" stroke-width=\"1\" rx=\"4\"><\/rect>\n  <text x=\"600\" y=\"100\" text-anchor=\"middle\" font-size=\"12\" font-weight=\"bold\" fill=\"#333\">\u56fe\u4f8b<\/text>\n  <rect x=\"545\" y=\"110\" width=\"14\" height=\"10\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"1\"><\/rect>\n  <text x=\"570\" y=\"118\" font-size=\"11\" fill=\"#555\">\u94a2\u677f\u4e3b\u4f53<\/text>\n  <line x1=\"545\" y1=\"130\" x2=\"559\" y2=\"130\" stroke=\"#d97706\" stroke-width=\"1.5\"><\/line>\n  <text x=\"570\" y=\"134\" font-size=\"11\" fill=\"#555\">\u5bf9\u6d41\u7fc5\u7247<\/text>\n  <circle cx=\"552\" cy=\"147\" r=\"5\" fill=\"#dc2626\"><\/circle>\n  <text x=\"570\" y=\"150\" font-size=\"11\" fill=\"#555\">\u8fdb\u6c34\u53e3<\/text>\n  <circle cx=\"552\" cy=\"163\" r=\"5\" fill=\"#0891b2\"><\/circle>\n  <text x=\"570\" y=\"166\" font-size=\"11\" fill=\"#555\">\u56de\u6c34\u53e3<\/text>\n<\/svg>\n<\/div>\n\n<div style=\"text-align:center; margin:32px 0;\">\n<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 680 280\" width=\"680\" height=\"280\" style=\"max-width:100%;background:#fff;border-radius:8px;padding:16px;border:1px solid #fde68a;\">\n  <text x=\"340\" y=\"24\" text-anchor=\"middle\" font-size=\"15\" font-weight=\"bold\" fill=\"#92400e\">\u4e0d\u540c\u7c7b\u578b\u6696\u6c14\u7247\u6563\u70ed\u7279\u6027\u5bf9\u6bd4<\/text>\n\n  <rect x=\"60\" y=\"50\" width=\"140\" height=\"30\" fill=\"#f59e0b\" rx=\"4\"><\/rect>\n  <text x=\"130\" y=\"70\" text-anchor=\"middle\" font-size=\"12\" fill=\"white\">\u94a2\u5236\u677f\u5f0f<\/text>\n  <rect x=\"60\" y=\"85\" width=\"140\" height=\"14\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"0.5\"><\/rect>\n  <text x=\"130\" y=\"96\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\">\u8f90\u5c0420% + \u5bf9\u6d4180%<\/text>\n  <rect x=\"80\" y=\"104\" width=\"100\" height=\"16\" fill=\"#dcfce7\" stroke=\"#22c55e\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"130\" y=\"116\" text-anchor=\"middle\" font-size=\"10\" fill=\"#166534\">\u5347\u6e29\u5feb\uff0c\u6c34\u5bb9\u91cf\u4f4e<\/text>\n  <rect x=\"80\" y=\"124\" width=\"100\" height=\"16\" fill=\"#dcfce7\" stroke=\"#22c55e\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"130\" y=\"136\" text-anchor=\"middle\" font-size=\"10\" fill=\"#166534\">\u710a\u70b9\u5c11\uff0c\u6f0f\u6c34\u98ce\u9669\u4f4e<\/text>\n  <rect x=\"80\" y=\"144\" width=\"100\" height=\"16\" fill=\"#fef9c3\" stroke=\"#f59e0b\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"130\" y=\"156\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\">\u9002\u5408\u666e\u901a\u5e73\u5c42<\/text>\n\n  <rect x=\"270\" y=\"50\" width=\"140\" height=\"30\" fill=\"#b45309\" rx=\"4\"><\/rect>\n  <text x=\"340\" y=\"70\" text-anchor=\"middle\" font-size=\"12\" fill=\"white\">\u94a2\u5236\u67f1\u5f0f<\/text>\n  <rect x=\"270\" y=\"85\" width=\"140\" height=\"14\" fill=\"#fef3c7\" stroke=\"#b45309\" stroke-width=\"0.5\"><\/rect>\n  <text x=\"340\" y=\"96\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\">\u8f90\u5c0450% + \u5bf9\u6d4150%<\/text>\n  <rect x=\"290\" y=\"104\" width=\"100\" height=\"16\" fill=\"#dcfce7\" stroke=\"#22c55e\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"340\" y=\"116\" text-anchor=\"middle\" font-size=\"10\" fill=\"#166534\">\u50a8\u6c34\u91cf\u5927\uff0c\u70ed\u60f0\u6027\u9ad8<\/text>\n  <rect x=\"290\" y=\"124\" width=\"100\" height=\"16\" fill=\"#dcfce7\" stroke=\"#22c55e\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"340\" y=\"136\" text-anchor=\"middle\" font-size=\"10\" fill=\"#166534\">\u9002\u5408\u6311\u9ad8\u7a7a\u95f4<\/text>\n  <rect x=\"290\" y=\"144\" width=\"100\" height=\"16\" fill=\"#fef9c3\" stroke=\"#f59e0b\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"340\" y=\"156\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\">\u8f90\u5c04\u5f3a\uff0c\u4e0d\u53d7\u70df\u56f1\u6548\u5e94\u5f71\u54cd<\/text>\n\n  <rect x=\"480\" y=\"50\" width=\"140\" height=\"30\" fill=\"#0891b2\" rx=\"4\"><\/rect>\n  <text x=\"550\" y=\"70\" text-anchor=\"middle\" font-size=\"12\" fill=\"white\">\u94dc\u94dd\u590d\u5408<\/text>\n  <rect x=\"480\" y=\"85\" width=\"140\" height=\"14\" fill=\"#e0f2fe\" stroke=\"#0891b2\" stroke-width=\"0.5\"><\/rect>\n  <text x=\"550\" y=\"96\" text-anchor=\"middle\" font-size=\"10\" fill=\"#0e7490\">\u8f90\u5c04+\u5bf9\u6d41\u5747\u8861<\/text>\n  <rect x=\"500\" y=\"104\" width=\"100\" height=\"16\" fill=\"#dcfce7\" stroke=\"#22c55e\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"550\" y=\"116\" text-anchor=\"middle\" font-size=\"10\" fill=\"#166534\">\u8010\u8150\u8680\u6027\u6781\u5f3a<\/text>\n  <rect x=\"500\" y=\"124\" width=\"100\" height=\"16\" fill=\"#dcfce7\" stroke=\"#22c55e\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"550\" y=\"136\" text-anchor=\"middle\" font-size=\"10\" fill=\"#166534\">\u9002\u5408\u6c34\u8d28\u8f83\u5dee\u5730\u533a<\/text>\n  <rect x=\"500\" y=\"144\" width=\"100\" height=\"16\" fill=\"#fef9c3\" stroke=\"#f59e0b\" stroke-width=\"0.5\" rx=\"3\"><\/rect>\n  <text x=\"550\" y=\"156\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\">\u5bff\u547d\u6700\u957f\uff0c\u4ef7\u683c\u8f83\u9ad8<\/text>\n\n  <rect x=\"90\" y=\"180\" width=\"80\" height=\"70\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <line x1=\"110\" y1=\"180\" x2=\"110\" y2=\"250\" stroke=\"#d97706\" stroke-width=\"1\" opacity=\"0.5\"><\/line>\n  <line x1=\"130\" y1=\"180\" x2=\"130\" y2=\"250\" stroke=\"#d97706\" stroke-width=\"1\" opacity=\"0.5\"><\/line>\n  <line x1=\"150\" y1=\"180\" x2=\"150\" y2=\"250\" stroke=\"#d97706\" stroke-width=\"1\" opacity=\"0.5\"><\/line>\n  <text x=\"130\" y=\"268\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u677f\u5f0f\uff08\u8584\u578b\uff09<\/text>\n\n  <rect x=\"300\" y=\"185\" width=\"20\" height=\"60\" fill=\"#fef3c7\" stroke=\"#b45309\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <rect x=\"325\" y=\"185\" width=\"20\" height=\"60\" fill=\"#fef3c7\" stroke=\"#b45309\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <rect x=\"350\" y=\"185\" width=\"20\" height=\"60\" fill=\"#fef3c7\" stroke=\"#b45309\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <rect x=\"375\" y=\"185\" width=\"20\" height=\"60\" fill=\"#fef3c7\" stroke=\"#b45309\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <text x=\"340\" y=\"268\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u67f1\u5f0f\uff08\u7acb\u4f53\uff09<\/text>\n\n  <rect x=\"510\" y=\"190\" width=\"30\" height=\"55\" fill=\"#e0f2fe\" stroke=\"#0891b2\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <rect x=\"545\" y=\"190\" width=\"30\" height=\"55\" fill=\"#e0f2fe\" stroke=\"#0891b2\" stroke-width=\"1.5\" rx=\"3\"><\/rect>\n  <rect x=\"510\" y=\"210\" width=\"30\" height=\"35\" fill=\"white\" stroke=\"#0891b2\" stroke-width=\"1\" opacity=\"0.5\"><\/rect>\n  <rect x=\"545\" y=\"210\" width=\"30\" height=\"35\" fill=\"white\" stroke=\"#0891b2\" stroke-width=\"1\" opacity=\"0.5\"><\/rect>\n  <text x=\"550\" y=\"268\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u94dc\u94dd\uff08\u590d\u5408\uff09<\/text>\n<\/svg>\n<\/div>\n\n<h3>\u54c1\u724c\u4e0e\u4ea7\u5730\u8be6\u60c5<\/h3>\n<table>\n  <thead><tr><th>\u9879\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td><strong>\u96c6\u56e2\u540d\u79f0<\/strong><\/td><td>Purmo Group Oyj\uff08\u539f\u745e\u7279\u683c Rettig \u96c6\u56e2\uff09<\/td><\/tr>\n    <tr><td><strong>\u96c6\u56e2\u66f4\u540d<\/strong><\/td><td>2019 \u5e74\uff0c\u745e\u7279\u683c ICC \u4f9b\u6696\u96c6\u56e2\u6b63\u5f0f\u66f4\u540d\u4e3a Purmo \u96c6\u56e2\uff08\u73bb\u739b\u96c6\u56e2\uff09<\/td><\/tr>\n    <tr><td><strong>\u4e2d\u56fd\u8fd0\u8425\u4e3b\u4f53<\/strong><\/td><td>\u73bb\u739b\u51b7\u6696\u73af\u5883\u8bbe\u5907\uff08\u6c5f\u82cf\uff09\u6709\u9650\u516c\u53f8<br><span style=\"font-size:13px;color:#78716c;\">\uff082023 \u5e74 3 \u6708\u7531\u300c\u745e\u7279\u683c\u4f9b\u6696\u8bbe\u5907\uff08\u6c5f\u82cf\uff09\u6709\u9650\u516c\u53f8\u300d\u66f4\u540d\uff09<\/span><\/td><\/tr>\n    <tr><td><strong>\u751f\u4ea7\u57fa\u5730<\/strong><\/td><td>\u6c5f\u82cf\u7701\u626c\u5dde\u5e02\u5434\u5dde\u4e1c\u8def 33 \u53f7<br><span style=\"font-size:13px;color:#78716c;\">\uff08Purmo \u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382 \u00b7 \u96c6\u56e2\u5728\u6b27\u6d32\u4ee5\u5916\u552f\u4e00\u751f\u4ea7\u57fa\u5730\uff09<\/span><\/td><\/tr>\n    <tr><td><strong>\u6295\u4ea7\u65f6\u95f4<\/strong><\/td><td>2019 \u5e74 9 \u6708\uff08\u626c\u5dde\u8f83\u65e9\u5f15\u8fdb\u7684\u82ac\u5170\u6295\u8d44\u4f01\u4e1a\uff09<\/td><\/tr>\n    <tr><td><strong>\u5236\u9020\u6807\u51c6<\/strong><\/td><td>EN 442 \uff0f DIN 55900<\/td><\/tr>\n    <tr><td><strong>\u8d28\u4fdd\u671f<\/strong><\/td><td>10 \u5e74<\/td><\/tr>\n    <tr><td><strong>\u54c1\u724c\u5173\u7cfb<\/strong><\/td><td><strong>\u73bb\u739b PURMO \u4e0e\u8fea\u8bfa DiaNorm \u4e3a\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d<\/strong>\uff08\u5e73\u66ff\uff09\uff0c\u578b\u53f7\u3001\u53c2\u6570\u3001\u8d28\u4fdd\u5b8c\u5168\u4e00\u81f4<\/td><\/tr>\n    <tr><td><strong>\u5168\u7403\u5e03\u5c40<\/strong><\/td><td>\u96c6\u56e2\u5728\u5168\u7403\u62e5\u6709 18 \u4e2a\u5de5\u5382\uff0c\u4ea7\u54c1\u8986\u76d6\u5fb7\u56fd\u3001\u5965\u5730\u5229\u3001\u8377\u5170\u3001\u6ce2\u5170\u3001\u4fc4\u7f57\u65af\u3001\u7f8e\u56fd\u3001\u65e5\u672c\u7b49\u5e02\u573a<\/td><\/tr>\n    <tr><td><strong>\u4e2d\u56fd\u5b98\u7f51<\/strong><\/td><td><a href=\"https:\/\/www.purmo.com.cn\" target=\"_blank\" style=\"color:#d97706;\">www.purmo.com.cn<\/a><\/td><\/tr>\n    <tr><td><strong>\u96c6\u56e2\u5b98\u7f51<\/strong><\/td><td><a href=\"https:\/\/www.purmo.com\" target=\"_blank\" style=\"color:#d97706;\">www.purmo.com<\/a><\/td><\/tr>\n    <tr><td><strong>\u54c1\u724c\u6765\u6e90<\/strong><\/td><td><strong>\u73bb\u739b PURMO \u6e90\u81ea\u82ac\u5170<\/strong>\uff081953 \u5e74\u521b\u7acb\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff09\uff1b<strong>\u8fea\u8bfa DiaNorm \u6e90\u81ea\u5fb7\u56fd<\/strong>\uff08\u5fb7\u56fd\u83f2\u5ae9\u5821 Vienenburg\uff0c1989 \u5e74\u5e76\u5165\u96c6\u56e2\uff09<br><span style=\"font-size:13px;color:#78716c;\">\uff08\u4e24\u8005\u540c\u5c5e Purmo \u96c6\u56e2\uff0c\u73b0\u7531\u96c6\u56e2\u626c\u5dde\u5de5\u5382\u7edf\u4e00\u751f\u4ea7\uff1b\u5382\u5740\u6c5f\u82cf\u626c\u5dde\u5434\u5dde\u4e1c\u8def 33 \u53f7\uff09<\/span><\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h3>\u8868\u9762\u5904\u7406\u5de5\u827a\uff08\u4e94\u6b65\uff09<\/h3>\n<p>\u73bb\u739b\u6696\u6c14\u7247\u8868\u9762\u5904\u7406\u4e25\u683c\u6309 <strong>DIN 55900<\/strong> \u6807\u51c6\u6267\u884c\uff0c\u6700\u7ec8\u989c\u8272\u4e3a <strong>RAL 9010 \u6807\u51c6\u767d\u8272<\/strong>\uff08\u73d0\u7405\u8d28\u767d\u8272\uff09\u3002\u82e5\u4fdd\u517b\u5f97\u5f53\uff0c10\u5e74\u540e\u8868\u9762\u8272\u5f69\u4ecd\u5982\u65b0\u3002<\/p>\n<table>\n  <thead><tr><th>\u6b65\u9aa4<\/th><th>\u5de5\u827a<\/th><th>\u4f5c\u7528<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td>\u7b2c1\u6b65<\/td><td><strong>\u53bb\u6cb9\u8102<\/strong><\/td><td>\u6e05\u6d17\u8868\u9762\u6cb9\u6c61\uff0c\u786e\u4fdd\u540e\u7eed\u6d82\u5c42\u9644\u7740\u529b<\/td><\/tr>\n    <tr><td>\u7b2c2\u6b65<\/td><td><strong>\u78f7\u5316\u5904\u7406<\/strong><\/td><td>\u9632\u9508\u949d\u5316\uff0c\u5f62\u6210\u4fdd\u62a4\u819c<\/td><\/tr>\n    <tr><td>\u7b2c3\u6b65<\/td><td><strong>KTL\u7535\u6cf3\u5e95\u6f06<\/strong><\/td><td>\u9634\u6781\u7535\u6cf3\u6d82\u88c5\uff0c\u6df1\u5c42\u9632\u8150\u8680<\/td><\/tr>\n    <tr><td>\u7b2c4\u6b65<\/td><td><strong>\u73af\u6c27\u6811\u8102\u7c89\u672b\u55b7\u6d82<\/strong><\/td><td>\u8010\u70ed\u8010\u78e8\u6811\u8102\u7c89\u672b\uff0c\u5747\u5300\u8986\u76d6<\/td><\/tr>\n    <tr><td>\u7b2c5\u6b65<\/td><td><strong>200\u2103\u9ad8\u6e29\u70d8\u70e4<\/strong><\/td><td>\u56fa\u5316\u6210\u578b\uff0c\u8868\u9762\u5149\u6d01\u8010\u4e45<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h3>\u6838\u5fc3\u6750\u8d28\u53c2\u6570<\/h3>\n<table>\n  <thead><tr><th>\u53c2\u6570<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td><strong>\u57fa\u677f\u6750\u8d28<\/strong><\/td><td>EN10130 DC01 AM \u7b49\u7ea7\u51b7\u8f67\u5e26\u94a2\u677f\uff0c\u540d\u4e49\u539a\u5ea6 1.25mm<\/td><\/tr>\n    <tr><td><strong>\u5bf9\u6d41\u7247\u6750\u8d28<\/strong><\/td><td>St12.03 \u51b7\u8f67\u5e26\u94a2\u677f\uff0c\u540d\u4e49\u539a\u5ea6 0.5mm<\/td><\/tr>\n    <tr><td><strong>\u91d1\u5c5e\u70ed\u5f3a\u5ea6<\/strong><\/td><td>\u5747\u5927\u4e8e <strong>1.1 W\/kg\u00b7\u2103<\/strong>\uff0c\u9ad8\u6548\u8282\u80fd<\/td><\/tr>\n    <tr><td><strong>\u6807\u51c6\u989c\u8272<\/strong><\/td><td>RAL 9010 \u767d\u8272<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<div class=\"highlight-box\">\n<strong>\u6838\u5fc3\u4f18\u52bf\uff1a<\/strong>\u6c34\u5bb9\u91cf\u4f4e\uff0c\u80fd\u5feb\u901f\u5b9e\u73b0\u5ba4\u5185\u6e29\u5ea6\u5347\u964d\uff0c\u4fdd\u8bc1\u6e29\u63a7\u8bbe\u5907\u7684\u6700\u4f73\u6548\u679c\u3002\u76f8\u6bd4\u4f20\u7edf\u94f8\u94c1\u6696\u6c14\u7247\u8282\u80fd15%-25%\uff0c20-30\u5206\u949f\u5185\u5373\u53ef\u8fbe\u5230\u8bbe\u5b9a\u5ba4\u6e29\u3002\n<\/div>\n\n<h2 id=\"xinghao\">\u4e09\u3001\u578b\u53f7\u89c4\u683c<\/h2>\n<p>\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6563\u70ed\u5668\u6309<strong>\u677f\u578b\u7ed3\u6784<\/strong>\u5206\u4e3a\u4ee5\u4e0b\u578b\u53f7\uff08\u7b26\u5408EN442\u6807\u51c6\uff09\uff1a<\/p>\n\n<table class=\"model-table\">\n  <thead>\n    <tr>\n      <th>\u578b\u53f7<\/th>\n      <th>EN442\u7c7b\u578b<\/th>\n      <th>\u7ed3\u6784\u8bf4\u660e<\/th>\n      <th>\u5bf9\u6d41\u7fc5\u7247<\/th>\n      <th>\u6563\u70ed\u7279\u70b9<\/th>\n      <th>\u9002\u7528\u573a\u666f<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr>\n      <td><strong>DNCV 10<\/strong><\/td>\n      <td>Type 10\uff08C11\uff09<\/td>\n      <td>\u5355\u677f\uff0c\u65e0\u5bf9\u6d41\u7247<\/td>\n      <td>\u65e0<\/td>\n      <td>\u8f90\u5c04\u4e3a\u4e3b\uff0c\u5347\u6e29\u8f83\u6162\uff0c\u5916\u89c2\u6700\u7b80\u6d01<\/td>\n      <td>\u4e0d\u63a8\u8350\uff08\u6563\u70ed\u6548\u7387\u4f4e\uff09<\/td>\n    <\/tr>\n    <tr>\n      <td><strong>DNCV 11<\/strong><\/td>\n      <td>Type 11\uff08C21\uff09<\/td>\n      <td>\u5355\u677f\uff0c\u5355\u9762\u5bf9\u6d41\u7247<\/td>\n      <td>1\u5c42\uff08\u5355\u9762\uff09<\/td>\n      <td>\u5bf9\u6d41\u589e\u5f3a\uff0c\u6bd4Type 10\u6563\u70ed\u9ad8\u7ea630%<\/td>\n      <td>\u7279\u6b8a\u9700\u6c42\u573a\u666f<\/td>\n    <\/tr>\n    <tr>\n      <td><strong>DNCV 20\uff082K\/C11\uff09<\/strong><\/td>\n      <td>Type 20<\/td>\n      <td>\u53cc\u677f\uff0c\u65e0\u5bf9\u6d41\u7247<\/td>\n      <td>\u65e0<\/td>\n      <td>\u8f90\u5c04\u4e3a\u4e3b\uff0c\u8868\u9762\u6e29\u5ea6\u5747\u5300\uff0c\u6c34\u5bb9\u91cf\u8f83\u5927<\/td>\n      <td>\u5bf9\u8f90\u5c04\u8212\u9002\u5ea6\u8981\u6c42\u9ad8\u7684\u573a\u666f<\/td>\n    <\/tr>\n    <tr>\n      <td><strong>DNCV 21\uff083K\/H21\uff09<\/strong><\/td>\n      <td>Type 21\uff08H21\uff09<\/td>\n      <td>\u53cc\u677f\uff0c\u5355\u9762\u5bf9\u6d41\u7247<\/td>\n      <td>1\u5c42<\/td>\n      <td>\u6563\u70ed\u5747\u8861\uff0c\u6700\u4e3b\u6d41<\/td>\n      <td>\u7edd\u5927\u591a\u6570\u666e\u901a\u4f4f\u5b85<strong>\uff08\u63a8\u8350\uff09<\/strong><\/td>\n    <\/tr>\n    <tr>\n      <td><strong>DNCV 22\uff084K\/H22\uff09<\/strong><\/td>\n      <td>Type 22\uff08H22\uff09<\/td>\n      <td>\u53cc\u677f\uff0c\u53cc\u9762\u5bf9\u6d41\u7247<\/td>\n      <td>2\u5c42<\/td>\n      <td>\u6563\u70ed\u91cf\u6700\u5927\uff0c\u5347\u6e29\u6700\u5feb<\/td>\n      <td>\u5927\u9762\u79ef\/\u6311\u9ad8\u7a7a\u95f4<\/td>\n    <\/tr>\n    <tr>\n      <td><strong>DNCV 33\uff085K\uff09<\/strong><\/td>\n      <td>Type 33<\/td>\n      <td>\u4e09\u677f\uff0c\u53cc\u9762\u5bf9\u6d41\u7247<\/td>\n      <td>2\u5c42\uff08\u4e09\u677f\u95f4\uff09<\/td>\n      <td>\u6563\u70ed\u91cf\u6781\u5927<\/td>\n      <td>\u5927\u7a7a\u95f4\/\u5546\u4e1a\u573a\u6240<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\n\n<div class=\"tip-box\">\n<strong>\u9f99\u8109\u63a8\u8350\uff1a<\/strong>\u666e\u901a\u4f4f\u5b85\u4f18\u5148\u9009\u62e9 <strong>DNCV 21\uff08Type 21\/3K\/H21\uff09<\/strong>\uff0c\u517c\u987e\u6563\u70ed\u6548\u7387\u548c\u5347\u6e29\u901f\u5ea6\u3002\u6311\u9ad8\u7a7a\u95f4\u6216\u5927\u9762\u79ef\u623f\u95f4\u53ef\u9009 DNCV 22\uff08Type 22\/4K\/H22\uff09\u3002\n<\/div>\n\n<div class=\"tip-box\">\n<strong>\u578b\u53f7\u8bf4\u660e\uff1a<\/strong>\u672c\u9875\u578b\u53f7\uff08<strong>DNCV \u7cfb\u5217<\/strong>\uff09\u5728\u73bb\u739b PURMO \u4e0e\u8fea\u8bfa DiaNorm \u4e24\u4e2a\u54c1\u724c\u4e0b<strong>\u5b8c\u5168\u4e00\u81f4<\/strong>\u2014\u2014\n\u4e24\u4e2a\u54c1\u724c\u540d\u5bf9\u5e94\u540c\u4e00\u6b3e\u4ea7\u54c1\uff0c\u578b\u53f7\u89c4\u683c\u3001\u9009\u578b\u53e3\u5f84\u3001\u6280\u672f\u53c2\u6570\u4e0e\u8d28\u4fdd\u653f\u7b56\u5747\u4e0d\u53d8\uff1b\u6838\u5bf9\u56fe\u7eb8\u4e0e\u4e0b\u5355\u65f6\u4ee5\u6b64\u578b\u53f7\u4e3a\u51c6\u3002\n<\/div>\n\n<h3>\u5e38\u7528\u5c3a\u5bf8\u89c4\u683c<\/h3>\n<h3>DNCV \u7cfb\u5217 \u2014 \u5185\u7f6e\u9600\u82af\u529f\u80fd<\/h3><p>DNCV \u7cfb\u5217\u5728 DNC \u57fa\u7840\u4e0a\u5185\u7f6e\u6e29\u63a7\u9600\u82af\uff0c\u652f\u6301 <strong>6 \u6863 Kv \u503c\u8c03\u8282<\/strong>\uff0c\u53ef\u5b9e\u73b0\u6c34\u529b\u5e73\u8861\u4e0e\u7cbe\u51c6\u6e29\u5ea6\u63a7\u5236\uff0c\u4e00\u52b3\u6c38\u9038\u89e3\u51b3\u7cfb\u7edf\u6c34\u529b\u5931\u8c03\u95ee\u9898\u3002<\/p><ul class=\"feature-list\">\n    <li><strong>Kv \u503c\u8c03\u8282<\/strong>\uff1a6 \u6863\u53ef\u8c03\uff0c\u9002\u914d\u4e0d\u540c\u73af\u8def\u963b\u529b<\/li>\n    <li><strong>\u6c34\u529b\u5e73\u8861<\/strong>\uff1a\u5185\u7f6e\u9600\u82af\u786e\u4fdd\u5404\u73af\u8def\u6d41\u91cf\u5747\u5300\u5206\u914d<\/li>\n    <li><strong>\u53cc\u7ba1\/\u5355\u7ba1\u517c\u5bb9<\/strong>\uff1a\u652f\u6301\u53cc\u7ba1\u7cfb\u7edf\uff08\u914d\u7403\u9600\uff09\u548c\u5355\u7ba1\u7cfb\u7edf\uff08\u914d H \u9600\u65c1\u901a\uff09<\/li>\n<\/ul><h3>\u5b9a\u8d27\u578b\u53f7\u6807\u8bc6\u65b9\u5f0f<\/h3><div class=\"highlight-box\">\n<strong>\u793a\u4f8b\uff1a<\/strong><code style=\"background:#fef3c7;padding:2px 8px;border-radius:4px;font-size:16px;\">DNC(V)22 - 600 - 1200<\/code>\n<\/div><table>\n  <thead>\n    <tr>\n      <th>\u9ad8\u5ea6\uff08mm\uff09<\/th>\n      <th>\u957f\u5ea6\uff08mm\uff09<\/th>\n      <th>\u63a5\u53e3\u65b9\u5f0f<\/th>\n      <th>\u9002\u7528\u623f\u95f4<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr>\n      <td>300<\/td>\n      <td>400 \/ 600 \/ 800 \/ 1000 \/ 1200 \/ 1400 \/ 1600 \/ 1800 \/ 2000<\/td>\n      <td>\u4fa7\u8fdb\u4fa7\u51fa<\/td>\n      <td>\u98d8\u7a97\u4e0b\u3001\u4f4e\u7a97\u53f0<\/td>\n    <\/tr>\n    <tr>\n      <td>450<\/td>\n      <td>400 \/ 600 \/ 800 \/ 1000 \/ 1200 \/ 1400 \/ 1600 \/ 1800 \/ 2000<\/td>\n      <td>\u4fa7\u8fdb\u4fa7\u51fa<\/td>\n      <td>\u4e2d\u7b49\u7a97\u53f0\u3001\u7075\u6d3b\u9002\u914d<\/td>\n    <\/tr>\n    <tr>\n      <td>600<\/td>\n      <td>400 \/ 600 \/ 800 \/ 1000 \/ 1200 \/ 1400 \/ 1600 \/ 1800 \/ 2000<\/td>\n      <td>\u4fa7\u8fdb\u4fa7\u51fa \/ \u5e95\u8fdb\u5e95\u51fa<\/td>\n      <td>\u666e\u901a\u7a97\u4e0b\uff08\u6700\u5e38\u7528\uff09<\/td>\n    <\/tr>\n    <tr>\n      <td>900<\/td>\n      <td>400 \/ 600 \/ 800 \/ 1000 \/ 1200 \/ 1400 \/ 1600 \/ 1800 \/ 2000<\/td>\n      <td>\u4fa7\u8fdb\u4fa7\u51fa<\/td>\n      <td>\u9ad8\u7a97\u53f0\u3001\u843d\u5730\u7a97<\/td>\n    <\/tr>\n    <tr>\n      <td>1600 \/ 1800<\/td>\n      <td>400 \/ 500 \/ 600 \/ 700 \/ 800<\/td>\n      <td>\u4fa7\u8fdb\u4fa7\u51fa<\/td>\n      <td>\u6311\u9ad8\u7a7a\u95f4\u3001\u67f1\u5f0f\u66ff\u4ee3<\/td>\n    <\/tr>\n\n<\/tbody><\/table><table style=\"margin-top:12px;\">\n  <tbody><tr><td><strong>DNC(V)<\/strong><\/td><td>\u7cfb\u5217\uff08C=\u590d\u5408\u578b\uff0cCV=\u5e26\u5185\u7f6e\u9600\u82af\uff09<\/td><\/tr>\n  <tr><td><strong>22<\/strong><\/td><td>\u578b\u53f7\uff080=\u65e0\u5bf9\u6d41\u7247\uff0c1=\u5355\u5bf9\u6d41\u7247\uff0c2=\u53cc\u5bf9\u6d41\u7247\uff0c3=\u4e09\u5bf9\u6d41\u7247\uff1b1=\u5355\u6c34\u9053\u677f\uff0c2=\u53cc\u6c34\u9053\u677f\uff0c3=\u4e09\u6c34\u9053\u677f\uff09<\/td><\/tr>\n  <tr><td><strong>600<\/strong><\/td><td>\u9ad8\u5ea6\uff08mm\uff09\uff0c\u53ef\u9009 300\/450\/600\/900<\/td><\/tr>\n  <tr><td><strong>1200<\/strong><\/td><td>\u957f\u5ea6\uff08mm\uff09\uff0c\u53ef\u9009 400\/600\/800\/1000\/1200\/1400\/1600\/1800\/2000\/2300\/2600\/3000<\/td><\/tr>\n<\/tbody><\/table>\n<\/div>\n\n<div style=\"text-align:center; margin:32px 0;\">\n<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 680 300\" width=\"680\" height=\"300\" style=\"max-width:100%;background:#fff;border-radius:8px;padding:16px;border:1px solid #fde68a;\">\n  <text x=\"340\" y=\"24\" text-anchor=\"middle\" font-size=\"15\" font-weight=\"bold\" fill=\"#92400e\">\u73bb\u739b\u6696\u6c14\u7247\u578b\u53f7 \u00d7 K\u503c \u00d7 \u677f\u578b\u7ed3\u6784 \u5bf9\u7167\u56fe<\/text>\n\n  <text x=\"80\" y=\"60\" text-anchor=\"middle\" font-size=\"12\" font-weight=\"bold\" fill=\"#92400e\">Type 10<\/text>\n  <rect x=\"40\" y=\"70\" width=\"80\" height=\"80\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"1.5\" rx=\"2\"><\/rect>\n  <text x=\"80\" y=\"165\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u5355\u677f \u65e0\u7fc5\u7247<\/text>\n  <text x=\"80\" y=\"180\" text-anchor=\"middle\" font-size=\"10\" fill=\"#b45309\">DNCV 10<\/text>\n\n  <text x=\"220\" y=\"60\" text-anchor=\"middle\" font-size=\"12\" font-weight=\"bold\" fill=\"#92400e\">Type 21\uff08\u63a8\u8350\uff09<\/text>\n  <rect x=\"180\" y=\"70\" width=\"80\" height=\"80\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"1.5\" rx=\"2\"><\/rect>\n  <line x1=\"192\" y1=\"75\" x2=\"192\" y2=\"145\" stroke=\"#d97706\" stroke-width=\"2\" opacity=\"0.6\"><\/line>\n  <text x=\"220\" y=\"165\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u53cc\u677f \u5355\u9762\u7fc5\u7247<\/text>\n  <text x=\"220\" y=\"180\" text-anchor=\"middle\" font-size=\"10\" fill=\"#16a34a\">\u2605 DNCV 21<\/text>\n\n  <text x=\"380\" y=\"60\" text-anchor=\"middle\" font-size=\"12\" font-weight=\"bold\" fill=\"#92400e\">Type 22\uff08\u5927\u7a7a\u95f4\uff09<\/text>\n  <rect x=\"340\" y=\"70\" width=\"80\" height=\"80\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"1.5\" rx=\"2\"><\/rect>\n  <line x1=\"352\" y1=\"75\" x2=\"352\" y2=\"145\" stroke=\"#d97706\" stroke-width=\"2\" opacity=\"0.6\"><\/line>\n  <line x1=\"408\" y1=\"75\" x2=\"408\" y2=\"145\" stroke=\"#d97706\" stroke-width=\"2\" opacity=\"0.6\"><\/line>\n  <text x=\"380\" y=\"165\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u53cc\u677f \u53cc\u9762\u7fc5\u7247<\/text>\n  <text x=\"380\" y=\"180\" text-anchor=\"middle\" font-size=\"10\" fill=\"#b45309\">DNCV 22<\/text>\n\n  <text x=\"540\" y=\"60\" text-anchor=\"middle\" font-size=\"12\" font-weight=\"bold\" fill=\"#92400e\">Type 33\uff08\u5546\u7528\uff09<\/text>\n  <rect x=\"500\" y=\"70\" width=\"80\" height=\"80\" fill=\"#fef3c7\" stroke=\"#f59e0b\" stroke-width=\"1.5\" rx=\"2\"><\/rect>\n  <line x1=\"512\" y1=\"75\" x2=\"512\" y2=\"145\" stroke=\"#d97706\" stroke-width=\"1.5\" opacity=\"0.5\"><\/line>\n  <line x1=\"540\" y1=\"75\" x2=\"540\" y2=\"145\" stroke=\"#d97706\" stroke-width=\"1.5\" opacity=\"0.5\"><\/line>\n  <line x1=\"568\" y1=\"75\" x2=\"568\" y2=\"145\" stroke=\"#d97706\" stroke-width=\"1.5\" opacity=\"0.5\"><\/line>\n  <text x=\"540\" y=\"165\" text-anchor=\"middle\" font-size=\"10\" fill=\"#78716c\">\u4e09\u677f \u53cc\u9762\u7fc5\u7247<\/text>\n  <text x=\"540\" y=\"180\" text-anchor=\"middle\" font-size=\"10\" fill=\"#b45309\">DNCV 33<\/text>\n\n  <rect x=\"100\" y=\"210\" width=\"480\" height=\"70\" fill=\"#fef9c3\" stroke=\"#f59e0b\" stroke-width=\"1\" rx=\"6\"><\/rect>\n  <text x=\"340\" y=\"232\" text-anchor=\"middle\" font-size=\"12\" font-weight=\"bold\" fill=\"#92400e\">\u26a0\ufe0f \u6ce8\u610f\uff1aK\u503c\u547d\u540d\u8bf4\u660e<\/text>\n  <text x=\"340\" y=\"252\" text-anchor=\"middle\" font-size=\"11\" fill=\"#78716c\">\u6b64\u4e3a\u9f99\u8109\u5185\u90e8\u7ea6\u5b9a\uff082K=\u53cc\u677f\u65e0\u5bf9\u6d41\uff0c3K=\u53cc\u677f\u5355\u5bf9\u6d41\uff0c4K=\u53cc\u677f\u53cc\u5bf9\u6d41\uff09<\/text>\n  <text x=\"340\" y=\"268\" text-anchor=\"middle\" font-size=\"11\" fill=\"#78716c\">\u4e0eEN 442\u6807\u51c6Type\u5206\u7c7b\uff08Type 21=\u53cc\u677f\u5355\u5bf9\u6d41\uff09\u4e0d\u540c\uff0c\u9009\u578b\u65f6\u8bf7\u6ce8\u610f\u533a\u5206<\/text>\n<\/svg>\n<\/div>\n\n<h2 id=\"canhuo\">\u56db\u3001\u6280\u672f\u53c2\u6570<\/h2>\n\n<table>\n  <thead>\n    <tr>\n      <th>\u53c2\u6570\u9879<\/th>\n      <th>\u73bb\u739b PURMO \u6807\u51c6\u503c<\/th>\n      <th>\u8bf4\u660e<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>\u5236\u9020\u6807\u51c6<\/td><td>EN 442-1:1996<\/td><td>\u6b27\u6d32\u6563\u70ed\u5668\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u6750\u8d28<\/td><td>EN 10130 \u51b7\u8f67\u4f4e\u78b3\u94a2<\/td><td>\u4f18\u8d28\u4f4e\u78b3\u94a2\uff0c\u8010\u8150\u8680<\/td><\/tr>\n    <tr><td>\u94a2\u677f\u539a\u5ea6<\/td><td>1.15mm \/ 1.25mm\uff08\u4f9d\u578b\u53f7\uff09<\/td><td>\u4f18\u4e8e\u884c\u4e1a\u6807\u51c6<\/td><\/tr>\n    <tr><td>\u5de5\u4f5c\u538b\u529b<\/td><td>\u226410 bar\uff081.0 MPa\uff09<\/td><td>\u5e38\u89c4\u91c7\u6696\u7cfb\u7edf\u538b\u529b 1.5-3 bar<\/td><\/tr>\n    <tr><td>\u8bd5\u9a8c\u538b\u529b<\/td><td>13.8 bar<\/td><td>\u51fa\u5382\u524d\u9010\u7247\u8bd5\u538b<\/td><\/tr>\n    <tr><td>\u6807\u51c6\u6563\u70ed\u91cf\u5de5\u51b5<\/td><td>\u4f9b\u6c3495\u2103 \/ \u56de\u6c3470\u2103 \/ \u5ba4\u6e2918\u2103<\/td><td>\u6807\u79f0\u6563\u70ed\u91cf\u57fa\u51c6<\/td><\/tr>\n    <tr><td>\u63a5\u53e3\u5c3a\u5bf8<\/td><td>G1\/2\u2033\uff08\u4fa7\u8fdb\u4fa7\u51fa\uff09\/ G3\/4\u2033\uff08\u5e95\u8fdb\u5e95\u51fa\uff09<\/td><td>\u6807\u914d<\/td><\/tr>\n    <tr><td>\u4e2d\u5fc3\u8ddd<\/td><td>\u9ad8\u5ea6-50mm\uff08\u5982600\u9ad8\u2192550mm\u4e2d\u5fc3\u8ddd\uff09<\/td><td>\u5b89\u88c5\u5c3a\u5bf8<\/td><\/tr>\n    <tr><td>\u8868\u9762\u5904\u7406<\/td><td>\u73af\u6c27\u805a\u916f\u7c89\u672b\uff0c\u9759\u7535\u55b7\u6d82\uff0c200\u2103\u56fa\u5316<\/td><td>\u9644\u7740\u529b\u5f3a\uff0c\u8010\u5019\u6027\u597d<\/td><\/tr>\n    <tr><td>\u6807\u914d\u9644\u4ef6<\/td><td>\u652f\u67b6\u3001\u87ba\u4e1d\u3001\u5835\u5934\u3001\u6392\u6c14\u9600<\/td><td>\u6bcf\u7247\u72ec\u7acb\u5305\u88c5<\/td><\/tr>\n    <tr><td>\u8d28\u4fdd\u671f<\/td><td>10\u5e74\uff08\u9650\u6b63\u89c4\u6e20\u9053\u8d2d\u4e70\uff09<\/td><td>\u73bb\u739b\u5b98\u65b9\u8d28\u4fdd\uff0c\u5bf9\u6750\u6599\u548c\u5236\u9020\u7f3a\u9677\u8d1f\u8d23\u7ef4\u4fee\u6216\u66f4\u6362<\/td><\/tr>\n    <tr><td><strong>\u8d28\u4fdd\u4e0d\u9002\u7528\u60c5\u5f62<\/strong><\/td><td colspan=\"2\">1. \u672a\u50a8\u85cf\u5728\u5e72\u71e5\u3001\u907f\u514d\u9633\u5149\u76f4\u5c04\u7684\u73af\u5883\u4e2d\u6216\u672a\u88ab\u8986\u76d6\uff1b2. \u4f7f\u7528\u5728&#8221;\u5f00\u5f0f\u4f9b\u70ed\u7cfb\u7edf&#8221;\u4e2d\u5bfc\u81f4\u5185\u90e8\u8150\u8680\uff1b3. \u975e\u6b63\u5e38\u50a8\u5b58\u3001\u5b89\u88c5\u53ca\u8fd0\u8f93\u5bfc\u81f4\u7684\u53d8\u5f62<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h3>DNC\/CV22 \u7cfb\u5217\u6807\u51b5\u6563\u70ed\u91cf\uff08W\uff09\u2014 \u25b3T=64.5\u2103\uff0c95\/70\/18\u2103<\/h3>\n<p style=\"font-size:13px;color:#78716c;\">\u6570\u636e\u5747\u7531\u4e2d\u56fd\u56fd\u5bb6\u7a7a\u8c03\u8bbe\u5907\u8d28\u91cf\u76d1\u7763\u68c0\u9a8c\u4e2d\u5fc3\u6839\u636e GB\/T 13754-1992 \u68c0\u6d4b\u83b7\u5f97\u3002<\/p>\n<table style=\"font-size:13px;\">\n  <thead>\n    <tr><th>\u957f\u5ea6(mm)<\/th><th>\u9ad8\u5ea6300<\/th><th>\u9ad8\u5ea6600<\/th><th>\u9ad8\u5ea6900<\/th><\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>400<\/td><td>539<\/td><td>980<\/td><td>1,322<\/td><\/tr>\n    <tr><td>600<\/td><td>808<\/td><td>1,470<\/td><td>1,983<\/td><\/tr>\n    <tr><td>800<\/td><td>1,077<\/td><td>1,960<\/td><td>2,643<\/td><\/tr>\n    <tr><td>1000<\/td><td>1,347<\/td><td>2,450<\/td><td>3,304<\/td><\/tr>\n    <tr><td>1200<\/td><td>1,616<\/td><td>2,940<\/td><td>3,965<\/td><\/tr>\n    <tr><td>1400<\/td><td>1,885<\/td><td>3,430<\/td><td>4,626<\/td><\/tr>\n    <tr><td>1600<\/td><td>2,155<\/td><td>3,920<\/td><td>5,287<\/td><\/tr>\n    <tr><td>1800<\/td><td>2,424<\/td><td>4,410<\/td><td>5,948<\/td><\/tr>\n    <tr><td>2000<\/td><td>2,693<\/td><td>4,900<\/td><td>6,608<\/td><\/tr>\n    <tr><td>2300<\/td><td>3,097<\/td><td>5,635<\/td><td>7,600<\/td><\/tr>\n    <tr><td>2600<\/td><td>3,501<\/td><td>\u2014<\/td><td>8,591<\/td><\/tr>\n    <tr><td>3000<\/td><td>4,040<\/td><td>7,350<\/td><td>9,913<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h3>DNC\/CV33 \u7cfb\u5217\u6807\u51b5\u6563\u70ed\u91cf\uff08W\uff09\u2014 \u25b3T=64.5\u2103\uff0c95\/70\/18\u2103<\/h3>\n<table style=\"font-size:13px;\">\n  <thead>\n    <tr><th>\u957f\u5ea6(mm)<\/th><th>\u9ad8\u5ea6300<\/th><th>\u9ad8\u5ea6600<\/th><th>\u9ad8\u5ea6900<\/th><\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>400<\/td><td>765<\/td><td>1,375<\/td><td>1,800<\/td><\/tr>\n    <tr><td>600<\/td><td>1,147<\/td><td>2,063<\/td><td>2,700<\/td><\/tr>\n    <tr><td>800<\/td><td>1,529<\/td><td>2,750<\/td><td>3,600<\/td><\/tr>\n    <tr><td>1000<\/td><td>1,912<\/td><td>3,438<\/td><td>4,500<\/td><\/tr>\n    <tr><td>1200<\/td><td>2,294<\/td><td>4,125<\/td><td>5,400<\/td><\/tr>\n    <tr><td>1400<\/td><td>2,676<\/td><td>4,813<\/td><td>6,301<\/td><\/tr>\n    <tr><td>1600<\/td><td>3,058<\/td><td>5,500<\/td><td>7,201<\/td><\/tr>\n    <tr><td>1800<\/td><td>3,441<\/td><td>6,188<\/td><td>8,101<\/td><\/tr>\n    <tr><td>2000<\/td><td>3,823<\/td><td>6,875<\/td><td>9,001<\/td><\/tr>\n    <tr><td>2300<\/td><td>4,396<\/td><td>7,907<\/td><td>10,351<\/td><\/tr>\n    <tr><td>2600<\/td><td>4,970<\/td><td>8,938<\/td><td>11,701<\/td><\/tr>\n    <tr><td>3000<\/td><td>5,735<\/td><td>10,313<\/td><td>13,501<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h3>\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u4f4e\u6e29\u5de5\u51b5\uff09<\/h3>\n<p>\u73bb\u739b\u6807\u79f0\u6563\u70ed\u91cf\u57fa\u4e8e\u6807\u51c6\u5de5\u51b5\uff0895\/70\/18\u2103\uff09\uff0c\u4f4e\u6e29\u7cfb\u7edf\u9700\u589e\u52a0\u6563\u70ed\u9762\u79ef\uff1a<\/p>\n<table>\n  <thead>\n    <tr>\n      <th>\u7cfb\u7edf\u7c7b\u578b<\/th>\n      <th>\u4f9b\u6c34\/\u56de\u6c34\u6e29\u5ea6<\/th>\n      <th>\u5b9e\u9645\u6563\u70ed\u91cf\u6bd4\u4f8b<\/th>\n      <th>\u5efa\u8bae\u589e\u52a0\u9762\u79ef<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>\u6807\u51c6\u5de5\u51b5<\/td><td>95\u2103\/70\u2103<\/td><td>100%<\/td><td>\u57fa\u51c6<\/td><\/tr>\n    <tr><td>\u5e38\u89c4\u7089\u9ad8\u6e29<\/td><td>80\u2103\/60\u2103<\/td><td>\u7ea676%<\/td><td>+32%<\/td><\/tr>\n    <tr><td>\u51b7\u51dd\u7089\u4f4e\u6e29<\/td><td>55\u2103\/45\u2103<\/td><td>\u7ea640%<\/td><td>+150%<\/td><\/tr>\n    <tr><td>\u7a7a\u6c14\u80fd\u4f4e\u6e29<\/td><td>45\u2103\/35\u2103<\/td><td>\u7ea623%<\/td><td>+335%<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<div class=\"warning-box\">\n<strong>\u26a0\ufe0f \u91cd\u8981\u63d0\u793a\uff1a<\/strong>\u51b7\u51dd\u7089\u6216\u7a7a\u6c14\u80fd\u914d\u6696\u6c14\u7247\u65f6\uff0c\u5fc5\u987b\u6309\u4f4e\u6e29\u5de5\u51b5\u91cd\u65b0\u8ba1\u7b97\u6563\u70ed\u9762\u79ef\uff0c\u5426\u5219\u5ba4\u6e29\u4e0d\u8fbe\u6807\u3002\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u70ed\u529b\u8ba1\u7b97\u670d\u52a1\u3002\n<\/div>\n\n<h2 id=\"duibi\">\u4e94\u3001\u7ade\u54c1\u5bf9\u6bd4<\/h2>\n\n<table class=\"comparison-table\">\n  <thead>\n    <tr>\n      <th>\u5bf9\u6bd4\u9879<\/th>\n      <th>\u73bb\u739b PURMO<\/th>\n      <th>\u56fd\u4ea7\u666e\u901a\u54c1\u724c<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td><strong>\u751f\u4ea7\u57fa\u5730<\/strong><\/td><td>\u4e2d\u56fd\u626c\u5dde \u00b7 Purmo \u96c6\u56e2\u81ea\u6709\u5de5\u5382<br><span style=\"font-size:13px;color:#78716c;\">\uff08\u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382 \u00b7 \u6b27\u6d32\u4ee5\u5916\u552f\u4e00\u751f\u4ea7\u57fa\u5730\uff09<\/span><\/td><td>\u56fd\u5185\u751f\u4ea7<\/td><\/tr>\n    <tr><td><strong>\u5236\u9020\u6807\u51c6<\/strong><\/td><td>EN 442<\/td><td>GB\/T 13754<\/td><\/tr>\n    <tr><td><strong>\u94a2\u677f\u539a\u5ea6<\/strong><\/td><td>1.15-1.25mm<\/td><td>0.8-1.0mm<\/td><\/tr>\n    <tr><td><strong>\u710a\u63a5\u5de5\u827a<\/strong><\/td><td>\u5168\u81ea\u52a8\u7535\u963b\u710a<\/td><td>\u624b\u5de5\u710a\/\u534a\u81ea\u52a8<\/td><\/tr>\n    <tr><td><strong>\u6c34\u5bb9\u91cf<\/strong><\/td><td>\u4f4e\uff08\u5347\u6e29\u5feb\uff09<\/td><td>\u8f83\u9ad8\uff08\u5347\u6e29\u6162\uff09<\/td><\/tr>\n    <tr><td><strong>\u8868\u9762\u5904\u7406<\/strong><\/td><td>\u9759\u7535\u55b7\u6d82+200\u2103\u56fa\u5316<\/td><td>\u55b7\u6d82\u5de5\u827a\u53c2\u5dee\u4e0d\u9f50<\/td><\/tr>\n    <tr><td><strong>\u8d28\u4fdd\u671f<\/strong><\/td><td>10\u5e74<\/td><td>2-5\u5e74<\/td><\/tr>\n    <tr><td><strong>\u4ef7\u683c\u533a\u95f4<\/strong><\/td><td>\u4e2d\u9ad8\u7aef<\/td><td>\u7ecf\u6d4e\u578b<\/td><\/tr>\n    <tr><td><strong>\u63a8\u8350\u6307\u6570<\/strong><\/td><td>\u2605\u2605\u2605\u2605\u2605<\/td><td>\u2605\u2605\u2605<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<div class=\"tip-box\" style=\"margin-top:14px;\">\n  <strong>\u4e3a\u4ec0\u4e48\u4e0d\u628a\u300c\u8fea\u8bfa DiaNorm\u300d\u5217\u8fdb\u7ade\u54c1\u5bf9\u6bd4\uff1f<\/strong>\n  \u8fea\u8bfa\uff08DiaNorm\uff09\u4e0e\u73bb\u739b\uff08PURMO\uff09\u662f\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d\u2014\u2014\u540c\u4e00\u96c6\u56e2\u3001\u540c\u4e00\u6761\u751f\u4ea7\u7ebf\u3001\u540c\u4e00\u5957 EN 442 \u6807\u51c6\uff0c\n  \u578b\u53f7\u4e0e\u6280\u672f\u53c2\u6570\u5b8c\u5168\u4e00\u81f4\u3002<strong>\u81ea\u5df1\u8ddf\u81ea\u5df1\u6bd4\u6ca1\u6709\u610f\u4e49\u3002<\/strong>\n  \u672c\u8868\u5bf9\u6bd4\u7684\u662f\u300c\u6b27\u6d32\u6807\u51c6\u677f\u5f0f\u6563\u70ed\u5668\u300d\u4e0e\u300c\u56fd\u4ea7\u666e\u901a\u677f\u5f0f\u6563\u70ed\u5668\u300d\u7684\u5dee\u522b\u3002\n<\/div>\n\n<h2 id=\"anzhuang\">\u516d\u3001\u5b89\u88c5\u8981\u70b9<\/h2>\n\n<ul class=\"feature-list\">\n    <li><strong>\u5b89\u88c5\u4f4d\u7f6e\u4f18\u5148\u7a97\u4e0b<\/strong>\uff1a\u5f62\u6210\u201d\u70ed\u5e55\u5e18\u201d\u963b\u6321\u51b7\u7a7a\u6c14\u6e17\u900f\uff0c\u662f\u6700\u4f73\u5b89\u88c5\u4f4d\u7f6e<\/li>\n    <li><strong>\u79bb\u5899\u8ddd\u79bb<\/strong>\uff1a\u5efa\u8bae30-50mm\uff0c\u4fdd\u8bc1\u5bf9\u6d41\u7a7a\u95f4<\/li>\n    <li><strong>\u652f\u67b6\u5b89\u88c5<\/strong>\uff1a\u4f7f\u7528\u539f\u5382\u652f\u67b6\uff0c\u786e\u4fdd\u627f\u91cd\u5b89\u5168\uff08\u6696\u6c14\u7247\u6ee1\u6c34\u91cd\u91cf\u53ef\u89c2\uff09<\/li>\n    <li><strong>\u7ba1\u9053\u8fde\u63a5<\/strong>\uff1a\u4f7f\u7528\u963b\u6c27\u7ba1\u9053\uff08PE-X\/\u94dd\u5851\u590d\u5408\u7ba1\uff09\uff0c\u9632\u6b62\u6c27\u6c14\u6e17\u900f\u8150\u8680<\/li>\n    <li><strong>\u7cfb\u7edf\u6e05\u6d17<\/strong>\uff1a\u5b89\u88c5\u5b8c\u6210\u540e\u5fc5\u987b\u51b2\u6d17\u7ba1\u8def\uff0c\u9632\u6b62\u6742\u8d28\u8fdb\u5165\u6696\u6c14\u7247\u5835\u585e\u6d41\u9053<\/li>\n    <li><strong>\u538b\u529b\u6d4b\u8bd5<\/strong>\uff1a\u5b89\u88c5\u5b8c\u6210\u540e\u8fdb\u884c1.5\u500d\u5de5\u4f5c\u538b\u529b\u8bd5\u538b\uff0c\u4fdd\u538b30\u5206\u949f\u4e0d\u964d\u538b<\/li>\n    <li><strong>\u6392\u6c14<\/strong>\uff1a\u6bcf\u7ec4\u6696\u6c14\u7247\u9ad8\u5904\u914d\u5907\u81ea\u52a8\u6392\u6c14\u9600\uff0c\u786e\u4fdd\u7cfb\u7edf\u65e0\u6c14\u963b<\/li>\n<\/ul>\n\n<h3>\u5b89\u88c5\u652f\u67b6\u89c4\u683c<\/h3>\n<table>\n  <thead><tr><th>\u9879\u76ee<\/th><th>\u89c4\u683c<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td><strong>\u652f\u67b6\u7c7b\u578b<\/strong><\/td><td>\u5fb7\u5f0f\u652f\u67b6\uff08\u9ad8\u5ea6\u5bf9\u5e94 300\/450\/600mm\uff09+ \u5f39\u7c27\u652f\u67b6\u914d\u5957<\/td><\/tr>\n    <tr><td><strong>\u6570\u91cf\u89c4\u5219<\/strong><\/td><td>\u957f\u5ea6 \u2264 1600mm\uff1a2 \u4e2a\u652f\u67b6\uff1b\u957f\u5ea6 &gt; 1800mm\uff1a3 \u4e2a\u652f\u67b6<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h3>\u5b89\u88c5\u95f4\u8ddd\u8981\u6c42<\/h3>\n<ul class=\"feature-list\">\n    <li>\u6563\u70ed\u5668<strong>\u4e0b\u90e8<\/strong>\u5e94\u7559\u6709\u81f3\u5c11 <strong>100mm<\/strong> \u7a7a\u9699\uff0c\u786e\u4fdd\u7a7a\u6c14\u6d41\u901a<\/li>\n    <li><strong>\u7a97\u53f0\u677f<\/strong>\u4e0e\u6563\u70ed\u5668\u4e4b\u95f4\u4e5f\u5e94\u7559\u81f3\u5c11 <strong>100mm<\/strong><\/li>\n    <li>\u63a8\u8350\u5b89\u88c5\u5728\u7a97\u4e0b\uff0c\u957f\u5ea6\u63a5\u8fd1\u7a97\u6237\u5bbd\u5ea6\uff0c\u5f62\u6210&#8221;\u70ed\u5e55\u5e18&#8221;\u6548\u679c<\/li>\n<\/ul>\n\n<h3>\u4f7f\u7528\u6761\u4ef6<\/h3>\n<table>\n  <thead><tr><th>\u6761\u4ef6<\/th><th>\u8981\u6c42<\/th><\/tr><\/thead>\n  <tbody>\n    <tr><td><strong>\u7cfb\u7edf\u7c7b\u578b<\/strong><\/td><td>\u9002\u7528\u4e8e\u95ed\u5f0f\u5faa\u73af\u4f4e\u6e29\u70ed\u6c34\u91c7\u6696\u7cfb\u7edf<\/td><\/tr>\n    <tr><td><strong>\u9632\u6c27\u8981\u6c42<\/strong><\/td><td>\u7cfb\u7edf\u5fc5\u987b\u6709\u6548\u963b\u6b62\u6c27\u6c14\u8fdb\u5165\uff0c\u542b\u6c27\u91cf\u4e0d\u8d85\u8fc7 <strong>0.1 mg\/L<\/strong><\/td><\/tr>\n    <tr><td><strong>pH \u503c<\/strong><\/td><td><strong>10-12<\/strong><\/td><\/tr>\n    <tr><td><strong>\u63a8\u8350\u4f9b\u6c34\u6e29\u5ea6<\/strong><\/td><td>\u2264 70\u2103\uff08\u4f4e\u6e29\u8fd0\u884c\u66f4\u8212\u9002\u3001\u8282\u80fd\uff09<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<div class=\"highlight-box\">\n<strong>\u9f99\u8109\u65bd\u5de5\u6807\u51c6\uff1a<\/strong>\u6240\u6709\u73bb\u739b\u6696\u6c14\u7247\u5b89\u88c5\uff0c\u5fc5\u987b\u4f7f\u7528\u5e26EVOH\u963b\u6c27\u5c42\u7684\u7ba1\u9053\uff0c\u5e76\u6dfb\u52a0F1\u4fdd\u62a4\u5242\uff0c\u4ece\u6839\u6e90\u4e0a\u9632\u6b62\u7535\u5316\u5b66\u8150\u8680\uff0c\u786e\u4fdd10\u5e74\u4ee5\u4e0a\u4f7f\u7528\u5bff\u547d\u3002\n<\/div>\n\n<h2 id=\"xuanxing\">\u4e03\u3001\u9009\u578b\u6307\u5357<\/h2>\n\n<h3>\u6563\u70ed\u91cf\u8ba1\u7b97\u516c\u5f0f<\/h3>\n<p>\u6240\u9700\u6696\u6c14\u7247\u7247\u6570 = \u623f\u95f4\u70ed\u8d1f\u8377\uff08W\uff09\u00f7 \u5355\u7ec4\u6696\u6c14\u7247\u6563\u70ed\u91cf\uff08W\uff09\u00d7 \u4fee\u6b63\u7cfb\u6570<\/p>\n\n<table>\n  <thead>\n    <tr>\n      <th>\u623f\u95f4\u7c7b\u578b<\/th>\n      <th>\u70ed\u8d1f\u8377\u53c2\u8003\uff08W\/\u33a1\uff09<\/th>\n      <th>\u8bf4\u660e<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>\u5367\u5ba4<\/td><td>100-120<\/td><td>\u4fdd\u6e29\u8f83\u597d\uff0c\u4eba\u5458\u5b89\u9759<\/td><\/tr>\n    <tr><td>\u5ba2\u5385<\/td><td>120-150<\/td><td>\u9762\u79ef\u5927\uff0c\u70ed\u635f\u5931\u8f83\u9ad8<\/td><\/tr>\n    <tr><td>\u4e66\u623f<\/td><td>90-110<\/td><td>\u4fdd\u6e29\u8f83\u597d<\/td><\/tr>\n    <tr><td>\u536b\u751f\u95f4<\/td><td>150-200<\/td><td>\u6e7f\u5ea6\u5927\uff0c\u901a\u98ce\u5f3a<\/td><\/tr>\n    <tr><td>\u6311\u9ad8\u5ba2\u5385<\/td><td>150-200<\/td><td>\u70ed\u7a7a\u6c14\u6613\u4e0a\u5347\u6d41\u5931<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<div class=\"tip-box\">\n<strong>\u5feb\u901f\u4f30\u7b97\uff1a<\/strong>\u6210\u90fd\u5730\u533a\u666e\u901a\u4f4f\u5b85\uff0c\u6309 <strong>120W\/\u33a1<\/strong> \u4f30\u7b97\u623f\u95f4\u70ed\u8d1f\u8377\uff0c\u518d\u6839\u636e\u6240\u9009\u6696\u6c14\u7247\u578b\u53f7\u7684\u5355\u7247\u6563\u70ed\u91cf\u8ba1\u7b97\u7247\u6570\u3002\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u7cfb\u7edf\u9700\u5728\u6b64\u57fa\u7840\u4e0a\u589e\u52a030-50%\u6563\u70ed\u9762\u79ef\u3002\n<\/div>\n\n<h2>\u73bb\u739b\u6696\u6c14\u7247\u63a8\u8350\u914d\u7f6e<\/h2>\n\n<table>\n  <thead>\n    <tr>\n      <th>\u6237\u578b\/\u573a\u666f<\/th>\n      <th>\u63a8\u8350\u578b\u53f7<\/th>\n      <th>\u9ad8\u5ea6\u9009\u62e9<\/th>\n      <th>\u914d\u7f6e\u8bf4\u660e<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>\u666e\u901a\u5e73\u5c42\u5367\u5ba4\uff0812-15\u33a1\uff09<\/td><td>DNCV 21\uff08Type 21\uff09<\/td><td>600mm<\/td><td>\u4e3b\u6d41\u914d\u7f6e\uff0c\u6563\u70ed\u5747\u8861<\/td><\/tr>\n    <tr><td>\u666e\u901a\u5e73\u5c42\u5ba2\u5385\uff0820-30\u33a1\uff09<\/td><td>DNCV 22\uff08Type 22\uff09<\/td><td>600mm<\/td><td>\u6563\u70ed\u91cf\u5927\uff0c\u5347\u6e29\u5feb<\/td><\/tr>\n    <tr><td>\u98d8\u7a97\/\u4f4e\u7a97\u53f0<\/td><td>DNCV 21<\/td><td>300mm<\/td><td>\u9002\u914d\u4f4e\u77ee\u7a7a\u95f4<\/td><\/tr>\n    <tr><td>\u6311\u9ad8\u5ba2\u5385\uff08&gt;3\u7c73\uff09<\/td><td>DNCV 22 \u6216 \u67f1\u5f0f<\/td><td>600mm \/ \u67f1\u5f0f\u9ad8\u7247<\/td><td>\u6311\u9ad8\u7a7a\u95f4\u5efa\u8bae\u67f1\u5f0f\uff08\u8f90\u5c04\u66f4\u5f3a\uff09<\/td><\/tr>\n    <tr><td>\u536b\u751f\u95f4<\/td><td>\u536b\u6d74\u80cc\u7bd3\uff08\u94a2\u5236\uff09<\/td><td>1200-1600mm<\/td><td>\u517c\u987e\u53d6\u6696+\u6bdb\u5dfe\u70d8\u5e72<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<h2 id=\"chanpin\">\u516b\u3001\u4ea7\u54c1\u56fe\u518c<\/h2>\n<p>\u4ee5\u4e0b\u662f\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u7684\u5178\u578b\u5e94\u7528\u573a\u666f\u6548\u679c\u56fe\uff08\u793a\u610f\u56fe\uff09\uff1a<\/p>\n\n<div class=\"product-img-grid\">\n\n  <div class=\"img-card\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-19.jpeg\" alt=\"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247 - \u5b98\u65b9\u6298\u9875\u5c01\u9762\" style=\"width:100%;height:auto;border-radius:6px 6px 0 0;\" loading=\"lazy\">\n    <p>\u73bb\u739b\u5b98\u65b9\u6298\u9875\u5c01\u9762 \u00b7 \u54c1\u724c\u5f62\u8c61\u5c55\u793a<\/p>\n  <\/div>\n\n  <div class=\"img-card\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-20-1024x621.jpeg\" alt=\"\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u9ad8\u6e05\u4ea7\u54c1\u5c55\u793a\" style=\"width:100%;height:auto;border-radius:6px 6px 0 0;\" loading=\"lazy\">\n    <p>\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247 \u00b7 \u9ad8\u6e05\u4ea7\u54c1\u5c55\u793a<\/p>\n  <\/div>\n\n  <div class=\"img-card\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-24-1024x730.jpeg\" alt=\"\u73bb\u739b\u6696\u6c14\u7247\u5b89\u88c5\u6548\u679c\u56fe\" style=\"width:100%;height:auto;border-radius:6px 6px 0 0;\" loading=\"lazy\">\n    <p>\u5b9e\u9645\u5b89\u88c5\u6548\u679c\u56fe \u00b7 \u7b80\u6d01\u7f8e\u89c2<\/p>\n  <\/div>\n\n  <div class=\"img-card\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-04.jpeg\" alt=\"\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u4ea7\u54c1\u56fe\" style=\"width:100%;height:auto;border-radius:6px 6px 0 0;\" loading=\"lazy\">\n    <p>\u6696\u6c14\u7247\u4ea7\u54c1\u7ec4\u56fe\uff08\u4e00\uff09<\/p>\n  <\/div>\n\n  <div class=\"img-card\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-09.jpeg\" alt=\"\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u4ea7\u54c1\u56fe\" style=\"width:100%;height:auto;border-radius:6px 6px 0 0;\" loading=\"lazy\">\n    <p>\u6696\u6c14\u7247\u4ea7\u54c1\u7ec4\u56fe\uff08\u4e8c\uff09<\/p>\n  <\/div>\n\n  <div class=\"img-card\">\n    <img decoding=\"async\" src=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-21.png\" alt=\"\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u4ea7\u54c1\u56fe\" style=\"width:100%;height:auto;border-radius:6px 6px 0 0;\" loading=\"lazy\">\n    <p>\u6696\u6c14\u7247\u4ea7\u54c1\u7ec4\u56fe\uff08\u4e09\uff09<\/p>\n  <\/div>\n\n<\/div>\n\n<h2 id=\"lianjie\">\u4e5d\u3001\u914d\u5957\u65b9\u6848<\/h2>\n<p>\u73bb\u739b\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\u9700\u8981\u4e0e\u4ee5\u4e0b\u7cfb\u7edf\u7ec4\u4ef6\u914d\u5957\u4f7f\u7528\uff0c\u624d\u80fd\u5b9e\u73b0\u6700\u4f73\u6548\u679c\uff1a<\/p>\n\n<table>\n  <thead>\n    <tr>\n      <th>\u914d\u5957\u7ec4\u4ef6<\/th>\n      <th>\u63a8\u8350\u54c1\u724c<\/th>\n      <th>\u8bf4\u660e<\/th>\n      <th>\u8be6\u60c5\u94fe\u63a5<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr>\n      <td><strong>\u58c1\u6302\u7089\uff08\u70ed\u6e90\uff09<\/strong><\/td>\n      <td>\u66fc\u745e\u5fb7 \/ \u83f2\u65af\u66fc \/ \u535a\u4e16<\/td>\n      <td>\u51b7\u51dd\u7089\u4e3a\u6700\u4f73\u5339\u914d\uff0c\u5e38\u89c4\u7089\u4e5f\u53ef\u7528<\/td>\n      <td><a href=\"https:\/\/longmai-nt.com\/?page_id=1841\" target=\"_blank\">\u66fc\u745e\u5fb7\u58c1\u6302\u7089\u8be6\u60c5<\/a><br><a href=\"https:\/\/longmai-nt.com\/?page_id=1824\" target=\"_blank\">\u83f2\u65af\u66fc\u58c1\u6302\u7089\u8be6\u60c5<\/a><br><a href=\"https:\/\/longmai-nt.com\/?page_id=835\" target=\"_blank\">\u535a\u4e16\u58c1\u6302\u7089\u8be6\u60c5<\/a><\/td>\n    <\/tr>\n    <tr>\n      <td><strong>\u7ba1\u9053\u7cfb\u7edf<\/strong><\/td>\n      <td>\u4f1f\u661f \/ \u7f8e\u6cb3\uff08\u963b\u6c27\u7ba1\uff09<\/td>\n      <td>\u5fc5\u987b\u4f7f\u7528EVOH\u963b\u6c27\u7ba1\uff0c\u9632\u6b62\u8150\u8680<\/td>\n      <td><a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\">\u5730\u6696\/\u6696\u6c14\u7247\u7cfb\u7edf\u8bf4\u660e<\/a><\/td>\n    <\/tr>\n    <tr>\n      <td><strong>\u6e29\u63a7\u7cfb\u7edf<\/strong><\/td>\n      <td>\u66fc\u745e\u5fb7\uff08\u7ebf\u63a7\u5668\/\u65e0\u7ebf\u6e29\u63a7\uff09<\/td>\n      <td>\u5206\u5ba4\u63a7\u6e29\uff0c\u8282\u80fd10-25%<\/td>\n      <td><a href=\"https:\/\/longmai-nt.com\/?page_id=2137\" target=\"_blank\">\u6696\u6c14\u7247\u63a7\u5236\u7cfb\u7edf\u8bf4\u660e<\/a><\/td>\n    <\/tr>\n    <tr>\n      <td><strong>\u660e\u88c5\u65b9\u6848<\/strong><\/td>\n      <td>\u9f99\u8109\u6696\u901a\u660e\u88c5\u4e13\u5c5e\u65b9\u6848<\/td>\n      <td>\u5df2\u88c5\u4fee\u623f\u5c4b\uff0c1-2\u5929\u5b8c\u5de5<\/td>\n      <td><a href=\"https:\/\/longmai-nt.com\/?page_id=2297#khalmznqp\" target=\"_blank\">\u660e\u88c5\u6696\u6c14\u7247\u6848\u4f8b<\/a><\/td>\n    <\/tr>\n    <tr>\n      <td><strong>\u65e5\u7acb\u7a7a\u6c14\u80fd<\/strong><\/td>\n      <td>\u65e5\u7acb\uff08\u4f4e\u6e29\u6696\u6c14\u7247\u65b9\u6848\uff09<\/td>\n      <td>\u7a7a\u6c14\u80fd\u9a71\u52a8\uff0c\u8fd0\u884c\u8d39\u770140-60%<\/td>\n      <td><a href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\">\u65e5\u7acb\u6c34\u5885\u9002\u8be6\u60c5<\/a><br><a href=\"https:\/\/longmai-nt.com\/?page_id=1957\" target=\"_blank\">\u65e5\u7acb\u667a\u4eab\u8be6\u60c5<\/a><\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\n\n<h2 id=\"faq\">\u5341\u3001\u5e38\u89c1\u95ee\u9898<\/h2>\n\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q1. \u73bb\u739b PURMO \u548c\u8fea\u8bfa DiaNorm \u662f\u4ec0\u4e48\u5173\u7cfb\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u4e8c\u8005\u662f<strong>\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d<\/strong>\u3002\u73bb\u739b PURMO \u662f<strong>\u82ac\u5170\u54c1\u724c<\/strong>\uff081953 \u5e74\u521b\u7acb\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff09\uff0c\u8fea\u8bfa DiaNorm \u662f<strong>\u5fb7\u56fd\u54c1\u724c<\/strong>\uff08\u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821 Vienenburg\uff09\uff1b\u4e24\u8005\u540c\u5c5e\u6b27\u6d32 Purmo \u96c6\u56e2\uff08\u539f\u745e\u7279\u683c ICC \u96c6\u56e2\uff09\u3002\u4e24\u4e2a\u54c1\u724c\u7684\u4ea7\u54c1\u7531\u96c6\u56e2\u6c5f\u82cf\u626c\u5dde\u81ea\u6709\u5de5\u5382\u540c\u4e00\u6761\u751f\u4ea7\u7ebf\u5236\u9020\uff0c\u9075\u5faa\u540c\u4e00\u5957 EN 442 \u6b27\u6d32\u6807\u51c6\uff0c\u578b\u53f7\u89c4\u683c\u3001\u6280\u672f\u53c2\u6570\u3001\u8d28\u4fdd\u653f\u7b56\u5b8c\u5168\u4e00\u81f4\uff0c\u4ec5\u54c1\u724c\u6807\u8bc6\u4e0d\u540c\u3002\u4e24\u4e2a\u54c1\u724c\u540d\u76ee\u524d\u90fd\u5728\u6b63\u5e38\u5728\u552e\uff0c\u884c\u4e1a\u91cc\u79f0\u8fd9\u79cd\u5173\u7cfb\u4e3a\u300c\u5e73\u66ff\u300d\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q2. \u73bb\u739b\u548c\u8fea\u8bfa\u6696\u6c14\u7247\u54ea\u4e2a\u597d\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u4ea7\u54c1\u672c\u8eab<strong>\u5b8c\u5168\u4e00\u6837<\/strong>\uff0c\u4e0d\u5b58\u5728\u54ea\u4e2a\u66f4\u597d\u7684\u95ee\u9898\u2014\u2014\u540c\u578b\u53f7\u3001\u540c\u53c2\u6570\u3001\u540c\u8d28\u4fdd\uff0c\u533a\u522b\u53ea\u662f\u54c1\u724c\u540d\u3002\u9009\u578b\u65f6\u60a8\u53ea\u9700\u6309\u623f\u95f4\u70ed\u8d1f\u8377\u786e\u5b9a\u578b\u53f7\u4e0e\u5c3a\u5bf8\uff0c\u54c1\u724c\u540d\u4ee5\u4e0b\u5355\u5408\u540c\u6807\u6ce8\u4e3a\u51c6\uff0c\u4ea4\u4ed8\u7684\u662f\u540c\u4e00\u6b3e\u4ea7\u54c1\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q3. \u73bb\u739b\u6696\u6c14\u7247\u662f\u54ea\u91cc\u751f\u4ea7\u7684\uff1f\u662f\u8fdb\u53e3\u7684\u5417\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u4ea7\u81ea<strong>\u4e2d\u56fd\u6c5f\u82cf\u626c\u5dde<\/strong>\uff0c<strong>\u4e0d\u662f\u8fdb\u53e3\u4ea7\u54c1<\/strong>\u3002\u8be5\u5de5\u5382\u662f Purmo \u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382\uff0c\u4e5f\u662f\u96c6\u56e2\u5728\u6b27\u6d32\u4ee5\u5916\u7684\u552f\u4e00\u751f\u4ea7\u57fa\u5730\uff0c2019 \u5e74 9 \u6708\u6295\u4ea7\uff0c\u6309\u6b27\u6d32 EN 442 \u6807\u51c6\u5236\u9020\u3002\u8fd9\u91cc\u8981\u5206\u6e05\u4e24\u4ef6\u4e8b\uff1a<strong>\u73bb\u739b PURMO \u662f\u82ac\u5170\u54c1\u724c\u3001\u8fea\u8bfa DiaNorm \u662f\u5fb7\u56fd\u54c1\u724c<\/strong>\uff0c\u6307\u7684\u662f\u54c1\u724c\u7684\u6765\u6e90\u5730\uff1b\u800c\u4e24\u4e2a\u54c1\u724c\u5728\u4e2d\u56fd\u9500\u552e\u7684\u4ea7\u54c1\uff0c\u90fd\u7531\u626c\u5dde\u5de5\u5382\u5236\u9020\uff0c<strong>\u4ea7\u5730\u662f\u4e2d\u56fd<\/strong>\u3002\u54c1\u724c\u6e90\u81ea\u6b27\u6d32\u3001\u5de5\u5382\u5728\u626c\u5dde\uff0c\u4e24\u53e5\u8bdd\u90fd\u6210\u7acb\uff0c\u672c\u9875\u6309\u5b9e\u9645\u60c5\u51b5\u5982\u5b9e\u6807\u6ce8\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q4. \u73bb\u739b PURMO \u662f\u54ea\u4e2a\u56fd\u5bb6\u7684\u54c1\u724c\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u73bb\u739b PURMO \u662f<strong>\u82ac\u5170\u54c1\u724c<\/strong>\u2014\u20141953 \u5e74\uff0c\u7b2c\u4e00\u7ec4\u94a2\u5236\u677f\u578b\u6563\u70ed\u5668\u5728\u82ac\u5170 Purmo \u5c0f\u9547\u8bde\u751f\uff0c\u54c1\u724c\u56e0\u6b64\u5f97\u540d\uff1b\u6240\u5c5e\u7684 Purmo \u96c6\u56e2\u603b\u90e8\u4f4d\u4e8e\u82ac\u5170\u8d6b\u5c14\u8f9b\u57fa\u3002\u9700\u8981\u7559\u610f\u7684\u662f\uff1a\u540c\u4e00\u96c6\u56e2\u65d7\u4e0b\u7684\u8fea\u8bfa DiaNorm \u662f<strong>\u5fb7\u56fd\u54c1\u724c<\/strong>\uff08\u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821 Vienenburg\uff09\uff0c\u4f46\u5b83\u4e0e\u73bb\u739b\u5728<strong>\u4e2d\u56fd\u9500\u552e\u7684\u4ea7\u54c1\uff0c\u90fd\u4ea7\u81ea\u96c6\u56e2\u6c5f\u82cf\u626c\u5dde\u5de5\u5382<\/strong>\uff0c\u4ea7\u5730\u662f\u4e2d\u56fd\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q5. \u73bb\u739b\u6696\u6c14\u7247\u7684\u8d28\u4fdd\u662f\u591a\u4e45\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u6574\u673a <strong>10 \u5e74\u8d28\u4fdd<\/strong>\u3002\u8d28\u4fdd\u8986\u76d6\u672c\u4f53\u710a\u63a5\u4e0e\u8868\u9762\u6d82\u5c42\u8d28\u91cf\uff1b\u4eba\u4e3a\u635f\u574f\u3001\u975e\u6388\u6743\u62c6\u6539\u3001\u7cfb\u7edf\u6c34\u8d28\u4e0d\u8fbe\u6807\uff08pH \u503c\u5f02\u5e38\u3001\u672a\u4f7f\u7528\u963b\u6c27\u7ba1\uff09\u5bfc\u81f4\u7684\u95ee\u9898\u4e0d\u5728\u8d28\u4fdd\u8303\u56f4\u5185\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q6. \u73bb\u739b\u6696\u6c14\u7247\u80fd\u914d\u51b7\u51dd\u7089\u6216\u7a7a\u6c14\u80fd\u5417\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u53ef\u4ee5\uff0c\u4f46<strong>\u5fc5\u987b\u6309\u4f4e\u6e29\u5de5\u51b5\u6362\u7b97\u6563\u70ed\u9762\u79ef<\/strong>\u3002\u51b7\u51dd\u7089\u4e0e\u7a7a\u6c14\u80fd\u51fa\u6c34\u6e29\u5ea6\u4e00\u822c\u5728 45\u201355\u2103\uff0c\u6563\u70ed\u5668\u5b9e\u9645\u6563\u70ed\u91cf\u4f1a\u660e\u663e\u4e0b\u964d\uff0c\u9009\u578b\u65f6\u9700\u8981\u67e5\u4f4e\u6e29\u6563\u70ed\u91cf\u8868\u3001\u9002\u5f53\u653e\u5927\u89c4\u683c\u3002\u672c\u9875\u300c\u56db\u3001\u6280\u672f\u53c2\u6570\u300d\u4e2d\u9644\u6709\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff0c\u53ef\u5bf9\u7167\u4f7f\u7528\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q7. DNCV \u7cfb\u5217\u578b\u53f7\u600e\u4e48\u8bfb\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u4ee5 <code>DNC(V)22-600-1200<\/code> \u4e3a\u4f8b\uff1a<strong>DN<\/strong> \u4e3a\u4ea7\u54c1\u4f53\u7cfb\u4ee3\u53f7\uff0c<strong>C<\/strong> \u8868\u793a\u590d\u5408\u578b\u677f\u5f0f\u7ed3\u6784\uff0c<strong>(V)<\/strong> \u8868\u793a\u5e26\u5185\u7f6e\u9600\u82af\uff08\u7528\u4e8e\u6c34\u529b\u5e73\u8861\uff09\u3001\u4e0d\u5e26 V \u5219\u4e3a\u6807\u51c6\u578b\uff1b<strong>22<\/strong> \u4e3a\u677f\u578b\uff082=\u53cc\u677f\u30012=\u53cc\u5bf9\u6d41\u7247\uff09\uff1b<strong>600<\/strong> \u4e3a\u9ad8\u5ea6 mm\uff1b<strong>1200<\/strong> \u4e3a\u957f\u5ea6 mm\u3002\u8be5\u578b\u53f7\u4f53\u7cfb\u5728\u73bb\u739b\u4e0e\u8fea\u8bfa\u4e24\u4e2a\u54c1\u724c\u4e0b\u5b8c\u5168\u4e00\u81f4\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q8. \u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u600e\u4e48\u88c5\uff1f\u8981\u591a\u4e45\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u660e\u88c5\u9002\u7528\u4e8e\u5df2\u88c5\u4fee\u623f\u5c4b\uff1a\u7ba1\u9053\u6cbf\u8e22\u811a\u7ebf\u3001\u9634\u89d2\u8d70\u7ebf\u5e76\u52a0\u6263\u69fd\u906e\u76d6\uff0c<strong>1\u20132 \u5929\u5b8c\u5de5<\/strong>\uff0c\u4e0d\u7834\u574f\u539f\u6709\u88c5\u4fee\uff0c\u5f53\u5929\u5373\u53ef\u4f7f\u7528\u3002\u6697\u88c5\u9700\u5728\u88c5\u4fee\u524d\u9884\u57cb\u7ba1\u8def\uff0c\u7f8e\u89c2\u5ea6\u66f4\u9ad8\u3002\u6211\u4eec\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u70ed\u529b\u8ba1\u7b97\uff0c\u6309\u6237\u578b\u51fa\u5177\u9009\u578b\u65b9\u6848\u3002<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #fde68a;border-radius:8px;padding:18px 20px;margin:14px 0;\">\n  <p style=\"margin:0 0 8px 0;font-weight:700;color:#92400e;font-size:16px;\">Q9. \u6696\u6c14\u7247\u548c\u5730\u6696\u600e\u4e48\u9009\uff1f<\/p>\n  <p style=\"margin:0;color:#4b5563;line-height:1.75;font-size:15px;\">\u5730\u6696\u5347\u6e29\u6162\u3001\u6e29\u5ea6\u5747\u5300\u3001\u8212\u9002\u5ea6\u9ad8\uff0c\u4f46\u5360\u5c42\u9ad8\u3001\u9700\u5728\u88c5\u4fee\u524d\u65bd\u5de5\uff0c\u9002\u5408\u957f\u671f\u5f00\u542f\u7684\u5bb6\u5ead\uff1b\u6696\u6c14\u7247\u5347\u6e29\u5feb\uff0820\u201330 \u5206\u949f\u5230\u6e29\uff09\u3001\u53ef\u5373\u5f00\u5373\u7528\u3001\u540e\u671f\u6539\u9020\u65b9\u4fbf\uff0c\u9002\u5408\u5df2\u88c5\u4fee\u623f\u5c4b\u6216\u9700\u8981\u7075\u6d3b\u63a7\u5236\u4f7f\u7528\u65f6\u95f4\u7684\u5bb6\u5ead\u3002\u4e24\u8005\u4e5f\u53ef\u5728\u540c\u4e00\u5957\u623f\u5185\u6df7\u88c5\uff08\u5982\u536b\u751f\u95f4+\u5ba2\u5385\u6696\u6c14\u7247\u3001\u5367\u5ba4\u5730\u6696\uff09\u3002<\/p>\n<\/div>\n\n<div style=\"background:#fffbeb; padding:32px; border-radius:8px; text-align:center; margin:40px 0; border:1px solid #fde68a;\">\n    <h3 style=\"margin-top:0; color:#92400e;\">\u9700\u8981\u73bb\u739b\u6696\u6c14\u7247\u9009\u578b\u62a5\u4ef7\uff1f<\/h3>\n    <p>\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3001\u70ed\u529b\u8ba1\u7b97\u3001\u65b9\u6848\u8bbe\u8ba1\u670d\u52a1<\/p>\n    <p style=\"margin:14px 0 18px 0;font-size:16px;color:#78350f;line-height:1.9;\"><strong>\u54a8\u8be2\u70ed\u7ebf\uff1a<\/strong><a href=\"tel:02886131795\" style=\"color:#78350f;text-decoration:none;font-weight:600;\">028-86131795<\/a>\uff08\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff09\u00b7 <a href=\"tel:02865272586\" style=\"color:#78350f;text-decoration:none;font-weight:600;\">028-65272586<\/a>\uff08\u6210\u534e\u533a\u5e97\uff09<br><strong>\u4e13\u5c5e\u987e\u95ee\uff1a<\/strong>\u4f59\u6653\u73b2 <a href=\"tel:13008113409\" style=\"color:#78350f;text-decoration:none;font-weight:600;\">130-0811-3409<\/a>\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/p>\n    <a href=\"https:\/\/longmai-nt.com\/contact\" class=\"cta-button\">\u9884\u7ea6\u514d\u8d39\u52d8\u6d4b<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2137\" class=\"cta-button blue\">\u67e5\u770b\u6696\u6c14\u7247\u7cfb\u7edf\u5168\u65b9\u6848<\/a>\n    <a href=\"https:\/\/longmai-nt.com\/?page_id=2297#khalmznqp\" class=\"cta-button\" style=\"background:#16a34a;\">\u67e5\u770b\u660e\u88c5\u6848\u4f8b<\/a>\n<\/div>\n\n<div style=\"background:#fffbeb; padding:28px 32px; border-radius:8px; margin:40px 0; border:1px solid #fde68a;\">\n    <h3 style=\"margin:0 0 20px 0; color:#92400e; font-size:18px;\">\u76f8\u5173\u63a8\u8350<\/h3>\n    <div style=\"display:grid; grid-template-columns:repeat(auto-fit, minmax(260px, 1fr)); gap:16px;\">\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=2137\" target=\"_blank\" style=\"display:block; padding:16px; background:#fff; border:1px solid #fde68a; border-radius:6px; text-decoration:none; color:#78350f; transition:all 0.2s;\">\n            <strong>\u6696\u6c14\u7247\u7cfb\u7edf\u5168\u65b9\u6848<\/strong>\n            <p style=\"margin:6px 0 0 0; font-size:14px; color:#a8a29e;\">\u4ece\u58c1\u6302\u7089\u5230\u6696\u6c14\u7247\uff0c\u4e00\u7ad9\u5f0f\u660e\u88c5\u6697\u88c5\u65b9\u6848<\/p>\n        <\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=2297#khalmznqp\" target=\"_blank\" style=\"display:block; padding:16px; background:#fff; border:1px solid #fde68a; border-radius:6px; text-decoration:none; color:#78350f; transition:all 0.2s;\">\n            <strong>\u660e\u88c5\u6696\u6c14\u7247\u6848\u4f8b<\/strong>\n            <p style=\"margin:6px 0 0 0; font-size:14px; color:#a8a29e;\">\u5df2\u88c5\u4fee\u623f\u5c4b1-2\u5929\u5b8c\u5de5\uff0c\u4e0d\u7834\u574f\u88c5\u4fee<\/p>\n        <\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" target=\"_blank\" style=\"display:block; padding:16px; background:#fff; border:1px solid #fde68a; border-radius:6px; text-decoration:none; color:#78350f; transition:all 0.2s;\">\n            <strong>\u5730\u6696\u7cfb\u7edf\u805a\u5408\u9875<\/strong>\n            <p style=\"margin:6px 0 0 0; font-size:14px; color:#a8a29e;\">\u5730\u6696 vs \u6696\u6c14\u7247\u5bf9\u6bd4\uff0c\u627e\u5230\u6700\u9002\u5408\u60a8\u7684\u65b9\u6848<\/p>\n        <\/a>\n        <a href=\"https:\/\/longmai-nt.com\/?page_id=1233\" target=\"_blank\" style=\"display:block; padding:16px; background:#fff; border:1px solid #fde68a; border-radius:6px; text-decoration:none; color:#78350f; transition:all 0.2s;\">\n            <strong>\u65e5\u7acb\u6c34\u5885\u9002<\/strong>\n            <p style=\"margin:6px 0 0 0; font-size:14px; color:#a8a29e;\">\u7a7a\u6c14\u80fd+\u6696\u6c14\u7247\uff0c\u8fd0\u884c\u8d39\u770140-60%<\/p>\n        <\/a>\n    <\/div>\n<\/div>\n<div style=\"border:1px solid #ececec;border-left:4px solid #c0392b;border-radius:10px;padding:12px 14px;margin:18px 0;background:#fff;\">\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=11894\" style=\"font-weight:700;color:#1a1a1a;text-decoration:none;display:block;font-size:1rem;\">\u6697\u57cb\u6696\u6c14\u7247\u8bbe\u8ba1\u89c4\u8303 V2.0\uff08\u5de5\u827a\u6807\u51c6\u767d\u76ae\u4e66\uff09<\/a>\n  <span style=\"font-size:.86rem;color:#606060;display:block;margin-top:3px;\">\u672c\u6848\u4f8b\u9075\u5faa\u7684\u8bbe\u8ba1\u6807\u51c6\uff1a\u56db\u8981\u7d20 + \u4e8c\u6b21\u7cfb\u7edf 4 \u6761\u5f3a\u5236\u5224\u636e + \u516b\u6b65\u6cd5\u9a8c\u6536\u6e05\u5355<\/span>\n<\/div>\n\n<hr style=\"margin:40px 0; border:none; border-top:1px solid #fde68a;\">\n<p style=\"text-align:center; color:#a8a29e; font-size:14px;\">\n    \u9f99\u8109\u6696\u901a \u00b7 \u6210\u90fd\u4e13\u4e1a\u6696\u901a\u670d\u52a1\u5546<br>\n    \u5b98\u7f51\uff1a<a href=\"https:\/\/longmai-nt.com\/\" style=\"color:#d97706;\">longmai-nt.com<\/a>\n    \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=2137\" style=\"color:#d97706;\">\u6696\u6c14\u7247\u7cfb\u7edf\u805a\u5408\u9875<\/a>\n    \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=1976\" style=\"color:#d97706;\">\u5730\u6696\u7cfb\u7edf\u805a\u5408\u9875<\/a>\n    \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=1879\" style=\"color:#d97706;\">\u70ed\u6c34\u7cfb\u7edf\u805a\u5408\u9875<\/a>\n    <br>\u670d\u52a1\u70ed\u7ebf\uff1a028-86131795\uff08\u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff09\u00b7 028-65272586\uff08\u6210\u534e\u533a\u5e97\uff09\n<\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08\u82ac\u5170\u54c1\u724c \u00b7 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09\",\n  \"alternateName\": \"\u8fea\u8bfa DiaNorm \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08\u5fb7\u56fd\u54c1\u724c\uff09\",\n  \"sku\": \"DNCV\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"\u73bb\u739b PURMO\uff08\u82ac\u5170\u54c1\u724c\uff09\",\n    \"alternateName\": \"DiaNorm \u8fea\u8bfa\uff08\u5fb7\u56fd\u54c1\u724c\uff09\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Purmo Group Oyj\uff08\u603b\u90e8\u82ac\u5170\u8d6b\u5c14\u8f9b\u57fa\uff09\",\n    \"alternateName\": \"\u539f\u745e\u7279\u683c Rettig ICC \u96c6\u56e2\"\n  },\n  \"model\": \"DNCV 10 \/ 11 \/ 20 \/ 21 \/ 22 \/ 33 \u7cfb\u5217\",\n  \"material\": \"EN 10130 \u51b7\u8f67\u4f4e\u78b3\u94a2\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u54c1\u724c\u6765\u6e90\",\n      \"value\": \"\u73bb\u739b PURMO \u6e90\u81ea\u82ac\u5170\uff081953 \u5e74\u521b\u7acb\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff09\uff1b\u8fea\u8bfa DiaNorm \u6e90\u81ea\u5fb7\u56fd\uff08\u83f2\u5ae9\u5821 Vienenburg\uff09\u3002\u4e24\u8005\u540c\u5c5e Purmo \u96c6\u56e2\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u5236\u9020\u6807\u51c6\",\n      \"value\": \"EN 442 \/ DIN 55900\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u751f\u4ea7\u57fa\u5730\",\n      \"value\": \"\u4e2d\u56fd\u6c5f\u82cf\u626c\u5dde\uff08Purmo \u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382\uff09\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u5de5\u4f5c\u538b\u529b\",\n      \"value\": \"\u226410 bar\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u6807\u51c6\u5de5\u51b5\",\n      \"value\": \"95\u2103\/70\u2103\/20\u2103\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u8d28\u4fdd\u671f\",\n      \"value\": \"10 \u5e74\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"\u4e0e\u8fea\u8bfa DiaNorm \u5173\u7cfb\",\n      \"value\": \"\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d\uff08\u5e73\u66ff\uff09\uff0c\u578b\u53f7\u4e0e\u53c2\u6570\u5b8c\u5168\u4e00\u81f4\"\n    }\n  ],\n  \"description\": \"\u73bb\u739b PURMO \u662f\u82ac\u5170\u54c1\u724c\uff081953 \u5e74\u521b\u7acb\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff09\uff0c\u4e0e\u5fb7\u56fd\u54c1\u724c\u8fea\u8bfa DiaNorm \u662f\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d\uff0c\u4e24\u8005\u540c\u5c5e Purmo \u96c6\u56e2\uff0c\u4ea7\u54c1\u5747\u4ea7\u81ea\u96c6\u56e2\u6c5f\u82cf\u626c\u5dde\u5de5\u5382\uff08\u4e2d\u56fd\u5236\u9020\uff0c\u975e\u8fdb\u53e3\uff09\u3002EN 442 \u6b27\u6d32\u6807\u51c6\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0cDNCV \u7cfb\u5217\u542b\u5185\u7f6e\u9600\u82af\u578b\u3002\u6210\u90fd\u9f99\u8109\u6696\u901a\u63d0\u4f9b\u9009\u578b\u3001\u6c34\u529b\u5e73\u8861\u8ba1\u7b97\u3001\u660e\u88c5\/\u6697\u88c5\u65b9\u6848\u4e0e\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u3002\",\n  \"url\": \"https:\/\/longmai-nt.com\/?page_id=2378\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"priceCurrency\": \"CNY\",\n    \"seller\": {\n      \"@type\": \"HVACBusiness\",\n      \"@id\": \"https:\/\/longmai-nt.com\/#organization\",\n      \"name\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\"\n    }\n  }\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u73bb\u739b PURMO \u548c\u8fea\u8bfa DiaNorm \u662f\u4ec0\u4e48\u5173\u7cfb\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4e8c\u8005\u662f\u540c\u4e00\u6b3e\u4ea7\u54c1\u7684\u4e24\u4e2a\u54c1\u724c\u540d\u3002\u73bb\u739b PURMO \u662f\u82ac\u5170\u54c1\u724c\uff081953 \u5e74\u521b\u7acb\u4e8e\u82ac\u5170 Purmo \u5c0f\u9547\uff09\uff0c\u8fea\u8bfa DiaNorm \u662f\u5fb7\u56fd\u54c1\u724c\uff08\u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821 Vienenburg\uff09\uff1b\u4e24\u8005\u540c\u5c5e\u6b27\u6d32 Purmo \u96c6\u56e2\uff08\u539f\u745e\u7279\u683c ICC \u96c6\u56e2\uff09\u3002\u4e24\u4e2a\u54c1\u724c\u7684\u4ea7\u54c1\u7531\u96c6\u56e2\u6c5f\u82cf\u626c\u5dde\u81ea\u6709\u5de5\u5382\u540c\u4e00\u6761\u751f\u4ea7\u7ebf\u5236\u9020\uff0c\u9075\u5faa\u540c\u4e00\u5957 EN 442 \u6b27\u6d32\u6807\u51c6\uff0c\u578b\u53f7\u89c4\u683c\u3001\u6280\u672f\u53c2\u6570\u3001\u8d28\u4fdd\u653f\u7b56\u5b8c\u5168\u4e00\u81f4\uff0c\u4ec5\u54c1\u724c\u6807\u8bc6\u4e0d\u540c\u3002\u4e24\u4e2a\u54c1\u724c\u540d\u76ee\u524d\u90fd\u5728\u6b63\u5e38\u5728\u552e\uff0c\u884c\u4e1a\u91cc\u79f0\u8fd9\u79cd\u5173\u7cfb\u4e3a\u300c\u5e73\u66ff\u300d\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u73bb\u739b\u548c\u8fea\u8bfa\u6696\u6c14\u7247\u54ea\u4e2a\u597d\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4ea7\u54c1\u672c\u8eab\u5b8c\u5168\u4e00\u6837\uff0c\u4e0d\u5b58\u5728\u54ea\u4e2a\u66f4\u597d\u7684\u95ee\u9898\u2014\u2014\u540c\u578b\u53f7\u3001\u540c\u53c2\u6570\u3001\u540c\u8d28\u4fdd\uff0c\u533a\u522b\u53ea\u662f\u54c1\u724c\u540d\u3002\u9009\u578b\u65f6\u60a8\u53ea\u9700\u6309\u623f\u95f4\u70ed\u8d1f\u8377\u786e\u5b9a\u578b\u53f7\u4e0e\u5c3a\u5bf8\uff0c\u54c1\u724c\u540d\u4ee5\u4e0b\u5355\u5408\u540c\u6807\u6ce8\u4e3a\u51c6\uff0c\u4ea4\u4ed8\u7684\u662f\u540c\u4e00\u6b3e\u4ea7\u54c1\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u73bb\u739b\u6696\u6c14\u7247\u662f\u54ea\u91cc\u751f\u4ea7\u7684\uff1f\u662f\u8fdb\u53e3\u7684\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4ea7\u81ea\u4e2d\u56fd\u6c5f\u82cf\u626c\u5dde\uff0c\u4e0d\u662f\u8fdb\u53e3\u4ea7\u54c1\u3002\u8be5\u5de5\u5382\u662f Purmo \u96c6\u56e2\u5168\u7403\u7b2c 18 \u4e2a\u5de5\u5382\uff0c\u4e5f\u662f\u96c6\u56e2\u5728\u6b27\u6d32\u4ee5\u5916\u7684\u552f\u4e00\u751f\u4ea7\u57fa\u5730\uff0c2019 \u5e74 9 \u6708\u6295\u4ea7\uff0c\u6309\u6b27\u6d32 EN 442 \u6807\u51c6\u5236\u9020\u3002\u8fd9\u91cc\u8981\u5206\u6e05\u4e24\u4ef6\u4e8b\uff1a\u73bb\u739b PURMO \u662f\u82ac\u5170\u54c1\u724c\u3001\u8fea\u8bfa DiaNorm \u662f\u5fb7\u56fd\u54c1\u724c\uff0c\u6307\u7684\u662f\u54c1\u724c\u7684\u6765\u6e90\u5730\uff1b\u800c\u4e24\u4e2a\u54c1\u724c\u5728\u4e2d\u56fd\u9500\u552e\u7684\u4ea7\u54c1\uff0c\u90fd\u7531\u626c\u5dde\u5de5\u5382\u5236\u9020\uff0c\u4ea7\u5730\u662f\u4e2d\u56fd\u3002\u54c1\u724c\u6e90\u81ea\u6b27\u6d32\u3001\u5de5\u5382\u5728\u626c\u5dde\uff0c\u4e24\u53e5\u8bdd\u90fd\u6210\u7acb\uff0c\u672c\u9875\u6309\u5b9e\u9645\u60c5\u51b5\u5982\u5b9e\u6807\u6ce8\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u73bb\u739b PURMO \u662f\u54ea\u4e2a\u56fd\u5bb6\u7684\u54c1\u724c\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u73bb\u739b PURMO \u662f\u82ac\u5170\u54c1\u724c\u2014\u20141953 \u5e74\uff0c\u7b2c\u4e00\u7ec4\u94a2\u5236\u677f\u578b\u6563\u70ed\u5668\u5728\u82ac\u5170 Purmo \u5c0f\u9547\u8bde\u751f\uff0c\u54c1\u724c\u56e0\u6b64\u5f97\u540d\uff1b\u6240\u5c5e\u7684 Purmo \u96c6\u56e2\u603b\u90e8\u4f4d\u4e8e\u82ac\u5170\u8d6b\u5c14\u8f9b\u57fa\u3002\u9700\u8981\u7559\u610f\u7684\u662f\uff1a\u540c\u4e00\u96c6\u56e2\u65d7\u4e0b\u7684\u8fea\u8bfa DiaNorm \u662f\u5fb7\u56fd\u54c1\u724c\uff08\u6e90\u81ea\u5fb7\u56fd\u83f2\u5ae9\u5821 Vienenburg\uff09\uff0c\u4f46\u5b83\u4e0e\u73bb\u739b\u5728\u4e2d\u56fd\u9500\u552e\u7684\u4ea7\u54c1\uff0c\u90fd\u4ea7\u81ea\u96c6\u56e2\u6c5f\u82cf\u626c\u5dde\u5de5\u5382\uff0c\u4ea7\u5730\u662f\u4e2d\u56fd\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u73bb\u739b\u6696\u6c14\u7247\u7684\u8d28\u4fdd\u662f\u591a\u4e45\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u6574\u673a 10 \u5e74\u8d28\u4fdd\u3002\u8d28\u4fdd\u8986\u76d6\u672c\u4f53\u710a\u63a5\u4e0e\u8868\u9762\u6d82\u5c42\u8d28\u91cf\uff1b\u4eba\u4e3a\u635f\u574f\u3001\u975e\u6388\u6743\u62c6\u6539\u3001\u7cfb\u7edf\u6c34\u8d28\u4e0d\u8fbe\u6807\uff08pH \u503c\u5f02\u5e38\u3001\u672a\u4f7f\u7528\u963b\u6c27\u7ba1\uff09\u5bfc\u81f4\u7684\u95ee\u9898\u4e0d\u5728\u8d28\u4fdd\u8303\u56f4\u5185\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u73bb\u739b\u6696\u6c14\u7247\u80fd\u914d\u51b7\u51dd\u7089\u6216\u7a7a\u6c14\u80fd\u5417\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u53ef\u4ee5\uff0c\u4f46\u5fc5\u987b\u6309\u4f4e\u6e29\u5de5\u51b5\u6362\u7b97\u6563\u70ed\u9762\u79ef\u3002\u51b7\u51dd\u7089\u4e0e\u7a7a\u6c14\u80fd\u51fa\u6c34\u6e29\u5ea6\u4e00\u822c\u5728 45\u201355\u2103\uff0c\u6563\u70ed\u5668\u5b9e\u9645\u6563\u70ed\u91cf\u4f1a\u660e\u663e\u4e0b\u964d\uff0c\u9009\u578b\u65f6\u9700\u8981\u67e5\u4f4e\u6e29\u6563\u70ed\u91cf\u8868\u3001\u9002\u5f53\u653e\u5927\u89c4\u683c\u3002\u672c\u9875\u300c\u56db\u3001\u6280\u672f\u53c2\u6570\u300d\u4e2d\u9644\u6709\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff0c\u53ef\u5bf9\u7167\u4f7f\u7528\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"DNCV \u7cfb\u5217\u578b\u53f7\u600e\u4e48\u8bfb\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u4ee5 DNC(V)22-600-1200 \u4e3a\u4f8b\uff1aDN \u4e3a\u4ea7\u54c1\u4f53\u7cfb\u4ee3\u53f7\uff0cC \u8868\u793a\u590d\u5408\u578b\u677f\u5f0f\u7ed3\u6784\uff0c(V) \u8868\u793a\u5e26\u5185\u7f6e\u9600\u82af\uff08\u7528\u4e8e\u6c34\u529b\u5e73\u8861\uff09\u3001\u4e0d\u5e26 V \u5219\u4e3a\u6807\u51c6\u578b\uff1b22 \u4e3a\u677f\u578b\uff082=\u53cc\u677f\u30012=\u53cc\u5bf9\u6d41\u7247\uff09\uff1b600 \u4e3a\u9ad8\u5ea6 mm\uff1b1200 \u4e3a\u957f\u5ea6 mm\u3002\u8be5\u578b\u53f7\u4f53\u7cfb\u5728\u73bb\u739b\u4e0e\u8fea\u8bfa\u4e24\u4e2a\u54c1\u724c\u4e0b\u5b8c\u5168\u4e00\u81f4\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6210\u90fd\u660e\u88c5\u6696\u6c14\u7247\u600e\u4e48\u88c5\uff1f\u8981\u591a\u4e45\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u660e\u88c5\u9002\u7528\u4e8e\u5df2\u88c5\u4fee\u623f\u5c4b\uff1a\u7ba1\u9053\u6cbf\u8e22\u811a\u7ebf\u3001\u9634\u89d2\u8d70\u7ebf\u5e76\u52a0\u6263\u69fd\u906e\u76d6\uff0c1\u20132 \u5929\u5b8c\u5de5\uff0c\u4e0d\u7834\u574f\u539f\u6709\u88c5\u4fee\uff0c\u5f53\u5929\u5373\u53ef\u4f7f\u7528\u3002\u6697\u88c5\u9700\u5728\u88c5\u4fee\u524d\u9884\u57cb\u7ba1\u8def\uff0c\u7f8e\u89c2\u5ea6\u66f4\u9ad8\u3002\u6211\u4eec\u63d0\u4f9b\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b\u4e0e\u70ed\u529b\u8ba1\u7b97\uff0c\u6309\u6237\u578b\u51fa\u5177\u9009\u578b\u65b9\u6848\u3002\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"\u6696\u6c14\u7247\u548c\u5730\u6696\u600e\u4e48\u9009\uff1f\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"\u5730\u6696\u5347\u6e29\u6162\u3001\u6e29\u5ea6\u5747\u5300\u3001\u8212\u9002\u5ea6\u9ad8\uff0c\u4f46\u5360\u5c42\u9ad8\u3001\u9700\u5728\u88c5\u4fee\u524d\u65bd\u5de5\uff0c\u9002\u5408\u957f\u671f\u5f00\u542f\u7684\u5bb6\u5ead\uff1b\u6696\u6c14\u7247\u5347\u6e29\u5feb\uff0820\u201330 \u5206\u949f\u5230\u6e29\uff09\u3001\u53ef\u5373\u5f00\u5373\u7528\u3001\u540e\u671f\u6539\u9020\u65b9\u4fbf\uff0c\u9002\u5408\u5df2\u88c5\u4fee\u623f\u5c4b\u6216\u9700\u8981\u7075\u6d3b\u63a7\u5236\u4f7f\u7528\u65f6\u95f4\u7684\u5bb6\u5ead\u3002\u4e24\u8005\u4e5f\u53ef\u5728\u540c\u4e00\u5957\u623f\u5185\u6df7\u88c5\uff08\u5982\u536b\u751f\u95f4+\u5ba2\u5385\u6696\u6c14\u7247\u3001\u5367\u5ba4\u5730\u6696\uff09\u3002\"\n      }\n    }\n  ]\n}\n<\/script>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08\u82ac\u5170\u54c1\u724c \u00b7 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09\",\n  \"author\": {\n    \"@type\": \"Person\",\n    \"@id\": \"https:\/\/longmai-nt.com\/#person-miaoyi\",\n    \"name\": \"\u7f2a\u5f02\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"@id\": \"https:\/\/longmai-nt.com\/#organization\",\n    \"name\": \"\u6210\u90fd\u9f99\u8109\u6696\u901a\"\n  },\n  \"mainEntityOfPage\": {\n    \"@type\": \"WebPage\",\n    \"@id\": \"https:\/\/longmai-nt.com\/?page_id=2378\"\n  },\n  \"dateModified\": \"2026-10-08\",\n  \"about\": [\n    {\n      \"@type\": \"Thing\",\n      \"name\": \"\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\"\n    },\n    {\n      \"@type\": \"Thing\",\n      \"name\": \"Purmo \u96c6\u56e2\"\n    },\n    {\n      \"@type\": \"Thing\",\n      \"name\": \"DiaNorm \u8fea\u8bfa\"\n    }\n  ]\n}\n<\/script>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08\u82ac\u5170\u54c1 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2378","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"description\" content=\"\u5fb7\u56fd\u8fea\u8bfa\uff08DIANORM\uff09\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u539f\u88c5\u8fdb\u53e3\uff0cEN442\u6807\u51c6\u3002DNCV21\uff083K\uff09\u4e3b\u6d41\u578b\u53f7\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0c\u5347\u6e29\u5feb\u3002\u9644\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u9700\u589e\u5927\u9762\u79ef\uff09\u3001\u578b\u53f7\u89c4\u683c\u5bf9\u6bd4\u3001\u9009\u578b\u516c\u5f0f\u3002\u9f99\u8109\u6696\u901a\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2378\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u5fb7\u56fd\u8fea\u8bfa\uff08DIANORM\uff09\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u539f\u88c5\u8fdb\u53e3\uff0cEN442\u6807\u51c6\u3002DNCV21\uff083K\uff09\u4e3b\u6d41\u578b\u53f7\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0c\u5347\u6e29\u5feb\u3002\u9644\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u9700\u589e\u5927\u9762\u79ef\uff09\u3001\u578b\u53f7\u89c4\u683c\u5bf9\u6bd4\u3001\u9009\u578b\u516c\u5f0f\u3002\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2378\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-09T14:30:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-18-1024x763.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378\",\"name\":\"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-nqp-dnnqp-18-1024x763.png\",\"datePublished\":\"2026-06-06T17:41:18+00:00\",\"dateModified\":\"2026-10-09T14:30:11+00:00\",\"description\":\"\u5fb7\u56fd\u8fea\u8bfa\uff08DIANORM\uff09\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u539f\u88c5\u8fdb\u53e3\uff0cEN442\u6807\u51c6\u3002DNCV21\uff083K\uff09\u4e3b\u6d41\u578b\u53f7\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0c\u5347\u6e29\u5feb\u3002\u9644\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u51b7\u51dd\u7089\\\/\u7a7a\u6c14\u80fd\u9700\u589e\u5927\u9762\u79ef\uff09\u3001\u578b\u53f7\u89c4\u683c\u5bf9\u6bd4\u3001\u9009\u578b\u516c\u5f0f\u3002\u9f99\u8109\u6696\u901a\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378#primaryimage\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-nqp-dnnqp-18-scaled.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/gw-nqp-dnnqp-18-scaled.png\",\"width\":2560,\"height\":1908},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2378#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09 - \u9f99\u8109\u6696\u901a","description":"\u5fb7\u56fd\u8fea\u8bfa\uff08DIANORM\uff09\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u539f\u88c5\u8fdb\u53e3\uff0cEN442\u6807\u51c6\u3002DNCV21\uff083K\uff09\u4e3b\u6d41\u578b\u53f7\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0c\u5347\u6e29\u5feb\u3002\u9644\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u9700\u589e\u5927\u9762\u79ef\uff09\u3001\u578b\u53f7\u89c4\u683c\u5bf9\u6bd4\u3001\u9009\u578b\u516c\u5f0f\u3002\u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2378","og_locale":"zh_CN","og_type":"article","og_title":"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09 - \u9f99\u8109\u6696\u901a","og_description":"\u5fb7\u56fd\u8fea\u8bfa\uff08DIANORM\uff09\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u539f\u88c5\u8fdb\u53e3\uff0cEN442\u6807\u51c6\u3002DNCV21\uff083K\uff09\u4e3b\u6d41\u578b\u53f7\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0c\u5347\u6e29\u5feb\u3002\u9644\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u9700\u589e\u5927\u9762\u79ef\uff09\u3001\u578b\u53f7\u89c4\u683c\u5bf9\u6bd4\u3001\u9009\u578b\u516c\u5f0f\u3002\u9f99\u8109\u6696\u901a","og_url":"https:\/\/longmai-nt.com\/?page_id=2378","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-10-09T14:30:11+00:00","og_image":[{"url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-18-1024x763.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"8 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2378","url":"https:\/\/longmai-nt.com\/?page_id=2378","name":"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longmai-nt.com\/?page_id=2378#primaryimage"},"image":{"@id":"https:\/\/longmai-nt.com\/?page_id=2378#primaryimage"},"thumbnailUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-18-1024x763.png","datePublished":"2026-06-06T17:41:18+00:00","dateModified":"2026-10-09T14:30:11+00:00","description":"\u5fb7\u56fd\u8fea\u8bfa\uff08DIANORM\uff09\u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff0c\u539f\u88c5\u8fdb\u53e3\uff0cEN442\u6807\u51c6\u3002DNCV21\uff083K\uff09\u4e3b\u6d41\u578b\u53f7\uff0c\u8f90\u5c04+\u5bf9\u6d41\u590d\u5408\u6563\u70ed\uff0c\u5347\u6e29\u5feb\u3002\u9644\u4f4e\u6e29\u5de5\u51b5\u6563\u70ed\u91cf\u6362\u7b97\u8868\uff08\u51b7\u51dd\u7089\/\u7a7a\u6c14\u80fd\u9700\u589e\u5927\u9762\u79ef\uff09\u3001\u578b\u53f7\u89c4\u683c\u5bf9\u6bd4\u3001\u9009\u578b\u516c\u5f0f\u3002\u9f99\u8109\u6696\u901a","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2378#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2378"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/?page_id=2378#primaryimage","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-18-scaled.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/06\/gw-nqp-dnnqp-18-scaled.png","width":2560,"height":1908},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2378#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u73bb\u739b PURMO \u94a2\u5236\u677f\u5f0f\u6696\u6c14\u7247\uff08 \u5fb7\u56fd\u8fea\u8bfa DiaNorm \u540c\u6b3e\uff09"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2378"}],"version-history":[{"count":7,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2378\/revisions"}],"predecessor-version":[{"id":14377,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2378\/revisions\/14377"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}