{"id":2501,"date":"2026-06-07T16:45:25","date_gmt":"2026-06-07T08:45:25","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2501"},"modified":"2026-06-07T16:45:25","modified_gmt":"2026-06-07T08:45:25","slug":"%e9%ba%93%e6%b9%96%e6%b2%84%e5%b2%b8%e6%b2%88%e5%b0%8f%e5%a7%90%e6%9a%96%e9%80%9a%e6%96%b9%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2501","title":{"rendered":"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66"},"content":{"rendered":"\n\n<style>\n  :root {\n    --red: #C8102E;\n    --dark: #1a1a2e;\n    --gold: #C9A84C;\n    --gold-light: #F0D690;\n    --bg: #F4F2EE;\n    --white: #FFFFFF;\n    --plan-a: #1558A8;\n    --plan-a-bg: #EEF4FF;\n    --plan-b: #7B1E4F;\n    --plan-b-bg: #FFF0F7;\n    --text: #1E1E1E;\n    --sub: #666;\n    --border: #DDD9D3;\n    --body-bg: #E8E4DD;\n  }\n  *, *::before, *::after { box-sizing: border-box; margin: 0; padding: 0; }\n  body { font-family: \"PingFang SC\",\"Microsoft YaHei\",\"Noto Sans SC\",sans-serif; background: var(--body-bg); color: var(--text); line-height: 1.7; font-size: 14px; }\n\n  \/* ======== WRAPPER (1024px card) ======== *\/\n  .wrapper { max-width: 1024px; margin: 0 auto; background: var(--bg); box-shadow: 0 0 60px rgba(0,0,0,.10); }\n\n  \/* ======== COVER ======== *\/\n  .cover {\n    background: linear-gradient(160deg, #080818 0%, #16102a 45%, #240f1a 80%, #0a0808 100%);\n    display: flex; flex-direction: column; align-items: center; justify-content: center;\n    text-align: center; padding: 80px 40px 64px; position: relative; overflow: hidden; color: #fff;\n  }\n  .cover::before {\n    content:''; position: absolute; inset: 0;\n    background: radial-gradient(ellipse 60% 50% at 30% 40%, rgba(200,16,46,.18) 0%, transparent 70%),\n                radial-gradient(ellipse 50% 40% at 72% 62%, rgba(201,168,76,.12) 0%, transparent 65%);\n  }\n  .c-eyebrow { font-size: 11px; letter-spacing: 5px; color: var(--gold); border: 1px solid var(--gold); padding: 5px 22px; display: inline-block; margin-bottom: 28px; text-transform: uppercase; position: relative; z-index: 1; }\n  .c-brand { font-size: 13px; letter-spacing: 6px; color: rgba(255,255,255,.45); margin-bottom: 8px; position: relative; z-index: 1; }\n  .c-title { font-size: 38px; font-weight: 800; letter-spacing: 2px; margin-bottom: 6px; position: relative; z-index: 1; }\n  .c-sub { font-size: 20px; color: var(--gold-light); margin-bottom: 36px; letter-spacing: 1px; position: relative; z-index: 1; }\n  .c-line { width: 60px; height: 2px; background: linear-gradient(90deg,transparent,var(--gold),transparent); margin: 0 auto 36px; }\n  .c-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 14px; max-width: 500px; margin: 0 auto 44px; position: relative; z-index: 1; }\n  .c-cell { background: rgba(255,255,255,.06); border: 1px solid rgba(255,255,255,.12); border-radius: 10px; padding: 14px 18px; text-align: left; }\n  .c-cell-label { font-size: 10px; letter-spacing: 2px; color: var(--gold); margin-bottom: 4px; }\n  .c-cell-val { font-size: 14px; color: #fff; font-weight: 600; }\n  .c-plans { display: flex; gap: 14px; position: relative; z-index: 1; margin-bottom: 44px; }\n  .c-plan { padding: 14px 28px; border-radius: 10px; font-size: 13px; font-weight: 700; letter-spacing: 1px; }\n  .c-plan.a { background: linear-gradient(135deg,#1558A8,#2a7fd4); }\n  .c-plan.b { background: linear-gradient(135deg,#7B1E4F,#b83373); }\n  .c-foot { font-size: 11px; letter-spacing: 3px; color: rgba(255,255,255,.25); margin-top: 10px; }\n\n  \/* ======== PAGE ======== *\/\n  .page { padding: 52px 32px; }\n\n  \/* ======== SECTION ======== *\/\n  .sec { margin-top: 64px; }\n  .sec:first-child { margin-top: 0; }\n  .sec-hd { display: flex; align-items: center; gap: 14px; padding-bottom: 14px; border-bottom: 2px solid var(--border); margin-bottom: 28px; }\n  .sec-num { width: 38px; height: 38px; border-radius: 50%; background: var(--red); color: #fff; font-size: 16px; font-weight: 800; display: flex; align-items: center; justify-content: center; flex-shrink: 0; }\n  .sec-ttl { font-size: 22px; font-weight: 800; color: var(--dark); }\n  .sec-desc { font-size: 12px; color: var(--sub); margin-top: 2px; }\n\n  \/* ======== TABLE ======== *\/\n  table { width: 100%; border-collapse: collapse; background: var(--white); border-radius: 14px; overflow: hidden; box-shadow: 0 2px 14px rgba(0,0,0,.07); margin-bottom: 22px; }\n  thead th { padding: 13px 15px; font-size: 12px; font-weight: 700; letter-spacing: 1px; color: #fff; text-align: left; }\n  thead.hd-a th { background: var(--plan-a); }\n  thead.hd-b th { background: var(--plan-b); }\n  thead.hd-dark th { background: var(--dark); }\n  thead.hd-gold th { background: linear-gradient(135deg,#7a5010,#C9A84C); }\n  tbody tr { border-bottom: 1px solid #EDEBE7; }\n  tbody tr:last-child { border-bottom: none; }\n  tbody tr:hover { background: #F9F8F5; }\n  td { padding: 11px 15px; vertical-align: middle; }\n  .tl { font-weight: 700; color: var(--dark); white-space: nowrap; }\n  .ts { font-size: 12px; color: var(--sub); display: block; font-weight: 400; }\n  .ta { color: var(--plan-a); font-weight: 700; }\n  .tb { color: var(--plan-b); font-weight: 700; }\n  .row-sub td { background: #F0F5FC; font-weight: 700; font-size: 13px; }\n  .row-sub .ta { color: var(--plan-a); }\n  .row-sub .tb { color: var(--plan-b); }\n  .row-total td { background: var(--dark); color: #fff; font-size: 15px; font-weight: 800; }\n  .row-total .ta { color: #8DC4FF; }\n  .row-total .tb { color: #FFB3D8; }\n  .row-add td { background: #FFF8E1; }\n  .td-note { font-size: 11px; color: var(--sub); }\n  .tag { display: inline-block; font-size: 10px; padding: 2px 8px; border-radius: 3px; font-weight: 700; margin-left: 5px; vertical-align: middle; }\n  .tag-g { background: #E7F9F0; color: #1a7a46; }\n  .tag-r { background: #FEE8E8; color: #b01c1c; }\n  .tag-n { background: #F0F0F0; color: #666; }\n\n  \/* ======== CARDS ======== *\/\n  .cards { display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin-bottom: 24px; }\n  .card { background: var(--white); border-radius: 14px; padding: 24px; border: 1px solid var(--border); box-shadow: 0 2px 12px rgba(0,0,0,.06); }\n  .card.ca { border-top: 4px solid var(--plan-a); }\n  .card.cb { border-top: 4px solid var(--plan-b); }\n  .badge { display: inline-block; font-size: 11px; font-weight: 800; letter-spacing: 1.5px; padding: 3px 10px; border-radius: 4px; margin-bottom: 10px; }\n  .badge-a { background: var(--plan-a-bg); color: var(--plan-a); }\n  .badge-b { background: var(--plan-b-bg); color: var(--plan-b); }\n  .price-big { font-size: 30px; font-weight: 800; }\n  .price-big.a { color: var(--plan-a); }\n  .price-big.b { color: var(--plan-b); }\n  .price-label { font-size: 12px; color: var(--sub); margin-top: 4px; }\n  .feat-list { list-style: none; padding: 0; margin: 0; }\n  .feat-list li { padding: 7px 0; border-bottom: 1px solid var(--border); font-size: 13px; display: flex; align-items: flex-start; gap: 8px; }\n  .feat-list li:last-child { border-bottom: none; }\n\n  \/* ======== SPEC GRID ======== *\/\n  .specs { display: grid; grid-template-columns: repeat(3,1fr); gap: 12px; margin-bottom: 22px; }\n  .spec { background: var(--white); border: 1px solid var(--border); border-radius: 10px; padding: 14px; text-align: center; }\n  .spec-val { font-size: 22px; font-weight: 800; color: var(--red); }\n  .spec-lbl { font-size: 11px; color: var(--sub); margin-top: 3px; }\n\n  \/* ======== NOTICE ======== *\/\n  .notice { background: #FFFBE5; border-left: 4px solid var(--gold); border-radius: 0 8px 8px 0; padding: 13px 18px; font-size: 13px; margin-bottom: 20px; color: #4a3a00; }\n  .notice strong { color: #2e2200; }\n  .notice-red { background: #FFF5F5; border-left-color: var(--red); color: #5a0000; }\n  .notice-red strong { color: #3a0000; }\n\n  \/* ======== PRICE NOTE ======== *\/\n  .pn { font-size: 11px; color: var(--sub); }\n  .formula { font-size: 12px; background: #F0F4FF; border: 1px solid #c6d6f5; border-radius: 6px; padding: 8px 14px; display: inline-block; color: var(--plan-a); font-weight: 600; margin-bottom: 14px; }\n\n  \/* ======== RADAR ======== *\/\n  .radar-box { background: var(--white); border-radius: 14px; padding: 32px; box-shadow: 0 2px 12px rgba(0,0,0,.06); border: 1px solid var(--border); margin-bottom: 22px; }\n  canvas { display: block; margin: 0 auto; }\n\n  \/* ======== VERDICT ======== *\/\n  .verdict { border-radius: 14px; padding: 26px; margin-bottom: 20px; border: 2px solid; }\n  .verdict.va { border-color: var(--plan-a); background: var(--plan-a-bg); }\n  .verdict.vb { border-color: var(--plan-b); background: var(--plan-b-bg); }\n  .verdict-ttl { font-size: 16px; font-weight: 800; margin-bottom: 10px; }\n  .verdict-ttl.a { color: var(--plan-a); }\n  .verdict-ttl.b { color: var(--plan-b); }\n  .verdict-body { font-size: 13px; line-height: 1.9; }\n\n  .rec-box {\n    background: linear-gradient(150deg,#0a0818 0%,#1e1030 40%,#240e14 80%,#080810 100%);\n    border-radius: 16px; padding: 40px; text-align: center; color: #fff; margin-bottom: 22px; position: relative; overflow: hidden;\n  }\n  .rec-box::before { content:''; position:absolute; inset:0; background: radial-gradient(ellipse at center, rgba(201,168,76,.18) 0%, transparent 70%); }\n  .rec-inner { position: relative; z-index: 1; }\n  .rec-star { font-size: 30px; margin-bottom: 8px; }\n  .rec-tag { font-size: 11px; letter-spacing: 4px; color: var(--gold); margin-bottom: 8px; }\n  .rec-plan { font-size: 24px; font-weight: 800; color: var(--gold-light); margin-bottom: 14px; }\n  .rec-reason { font-size: 13px; color: rgba(255,255,255,.75); line-height: 1.9; max-width: 560px; margin: 0 auto; }\n\n  \/* ======== SOURCE LINK ======== *\/\n  .src-link { display: inline-flex; align-items: center; gap: 5px; font-size: 11px; padding: 4px 12px; border-radius: 20px; border: 1px solid; text-decoration: none; margin-top: 8px; }\n  .src-link.la { border-color: var(--plan-a); color: var(--plan-a); }\n  .src-link.lb { border-color: var(--plan-b); color: var(--plan-b); }\n\n  \/* ======== FIVE-CONSTANT BADGE ======== *\/\n  .five-const {\n    display: inline-block; font-size: 11px; font-weight: 800; letter-spacing: 2px;\n    background: linear-gradient(135deg,#7B1E4F,#b83373); color: #fff;\n    padding: 3px 12px; border-radius: 4px; margin-left: 8px;\n  }\n\n  \/* ======== FOOTER ======== *\/\n  .footer { text-align: center; padding: 40px 32px; border-top: 1px solid var(--border); font-size: 11px; color: var(--sub); }\n  .footer strong { color: var(--red); }\n\n  @media (max-width: 739px) {\n    .wrapper { max-width: 100%; }\n    .page { padding: 36px 16px; }\n    .cards { grid-template-columns: 1fr; }\n    .specs { grid-template-columns: repeat(2,1fr); }\n    .c-grid { grid-template-columns: 1fr; }\n    .c-plans { flex-direction: column; }\n    .c-title { font-size: 26px; }\n    .cover { padding: 48px 20px 40px; }\n    .footer { padding: 32px 16px; }\n  }\n<\/style>\n\n<div class=\"wrapper\">\n\n<!-- ====== COVER ====== -->\n<div class=\"cover\">\n  <div class=\"c-eyebrow\">Proposal \u00b7 June 2026<\/div>\n  <div class=\"c-brand\">HITACHI \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03 \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n  <div class=\"c-title\">\u65b9\u6848\u62a5\u4ef7\u5168\u4e66<\/div>\n  <div class=\"c-sub\">\u9e93\u6e56\u6c84\u5cb8 \u00b7 \u6c88\u5c0f\u59d0 \u00b7 \u5e9c\u90b8\u51b7\u6696\u65b0\u98ce\u5168\u5c4b\u65b9\u6848<\/div>\n  <div class=\"c-line\"><\/div>\n  <div class=\"c-grid\">\n    <div class=\"c-cell\"><div class=\"c-cell-label\">\u9879\u76ee\u5730\u5740<\/div><div class=\"c-cell-val\">\u9e93\u6e56\u6c84\u5cb8<\/div><\/div>\n    <div class=\"c-cell\"><div class=\"c-cell-label\">\u4e1a\u4e3b<\/div><div class=\"c-cell-val\">\u6c88\u5c0f\u59d0<\/div><\/div>\n    <div class=\"c-cell\"><div class=\"c-cell-label\">\u91c7\u6696\/\u7a7a\u8c03\u9762\u79ef<\/div><div class=\"c-cell-val\">133 \u33a1<\/div><\/div>\n    <div class=\"c-cell\"><div class=\"c-cell-label\">\u7cfb\u7edf\u7c7b\u578b<\/div><div class=\"c-cell-val\">\u4e8c\u8054\u4f9b + \u65b0\u98ce<\/div><\/div>\n    <div class=\"c-cell\"><div class=\"c-cell-label\">\u5e38\u4f4f\u4eba\u53e3<\/div><div class=\"c-cell-val\">3 ~ 5 \u4f4d<\/div><\/div>\n    <div class=\"c-cell\"><div class=\"c-cell-label\">\u5236\u4f5c\u65e5\u671f<\/div><div class=\"c-cell-val\">2026\u5e746\u67087\u65e5<\/div><\/div>\n  <\/div>\n  <div class=\"c-plans\">\n    <div class=\"c-plan a\">\u65b9\u6848 A \u00b7 \u65e5\u7acb\u65b0\u667a\u4eab\uff08\u5929\u6c1f\u5730\u6c34\uff09+ \u65b0\u98ce<\/div>\n    <div class=\"c-plan b\">\u65b9\u6848 B \u00b7 \u65e5\u7acb\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf<\/div>\n  <\/div>\n  <div class=\"c-foot\">LONGMAI WARM TECH \u00b7 \u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546 \u00b7 \u00a9 2004-2026<\/div>\n<\/div>\n\n<!-- ====== MAIN ====== -->\n<div class=\"page\">\n\n<!-- 01 \u5ba2\u6237\u9700\u6c42 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">01<\/div>\n    <div><div class=\"sec-ttl\">\u5ba2\u6237\u9700\u6c42\u5206\u6790<\/div><div class=\"sec-desc\">\u7a7a\u95f4\u5e03\u5c40 \u00b7 \u4f7f\u7528\u4e60\u60ef \u00b7 \u6838\u5fc3\u8bc9\u6c42<\/div><\/div>\n  <\/div>\n  <div class=\"specs\">\n    <div class=\"spec\"><div class=\"spec-val\">133\u33a1<\/div><div class=\"spec-lbl\">\u91c7\u6696\/\u7a7a\u8c03\u9762\u79ef<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">3~5\u4eba<\/div><div class=\"spec-lbl\">\u5e38\u4f4f\u4eba\u53e3<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">160\u5339<\/div><div class=\"spec-lbl\">\u5916\u673a\u914d\u7f6e\u5bb9\u91cf<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">5\u53f0\u5185\u673a<\/div><div class=\"spec-lbl\">\u7a7a\u8c03\u5ba4\u5185\u672b\u7aef<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">\u5929\u51c0\u65b0\u98ce350<\/div><div class=\"spec-lbl\">\u65b0\u98ce\u5168\u70ed\u4ea4\u6362<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">\u5236\u51b7\u5feb\u00b7\u5065\u5eb7<\/div><div class=\"spec-lbl\">\u6838\u5fc3\u8bc9\u6c42<\/div><\/div>\n  <\/div>\n  <div class=\"notice\">\n    <strong>\ud83d\udccb \u9700\u6c42\u89e3\u8bfb\uff1a<\/strong>\u5ba2\u9910\u5385+\u4e66\u623f\uff0875\u33a1\uff09\u65e5\u5e38\u5168\u5f00\u4e3a\u4e3b\u529b\u533a\uff0c\u4e3b\u5367\u5e38\u5f00\uff0c\u6b21\u5367\u89c6\u6765\u5ba2\u4eba\u6570\u7075\u6d3b\u5f00\u542f\u3002\u6c88\u5c0f\u59d0\u4e0e\u5927\u91d1\u65b9\u6848\u5bf9\u6bd4\u4e2d\uff0c\u9996\u8981\u5173\u6ce8\u5236\u51b7\u901f\u5ea6\u53ca\u6027\u4ef7\u6bd4\uff0c\u9690\u6027\u4e0a\u5bf9\u7a7a\u6c14\u51c0\u5316\u3001\u65b0\u98ce\u6052\u6c27\u3001\u9664\u6e7f\u8212\u9002\u5ea6\u4e5f\u6709\u671f\u5f85\u3002\u5ba2\u6237\u660e\u786e\u9700\u6c42\u5929\u51c0\u65b0\u98ce350\u4e00\u53f0\uff0c\u4e3a\u5168\u5bb6\u63d0\u4f9b\u5168\u70ed\u4ea4\u6362\u6052\u6c27\u6052\u51c0\u7a7a\u6c14\u73af\u5883\u3002\n  <\/div>\n  <table>\n    <thead class=\"hd-dark\">\n      <tr><th>\u7a7a\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u4f7f\u7528\u9891\u7387<\/th><th>\u914d\u7f6e\u5185\u673a\u578b<\/th><th>\u5907\u6ce8<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr><td class=\"tl\">\u5ba2\u9910\u5385 + \u5f00\u653e\u4e66\u623f<\/td><td>75 \u33a1<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5168\u5f00<\/td><td>71\u578b + 32\u578b\uff08\u4e24\u53f0\uff09<\/td><td>\u4e66\u623f\u5e38\u6001\u6253\u5f00\uff0c\u4e00\u4f53\u5927\u7a7a\u95f4<\/td><\/tr>\n      <tr><td class=\"tl\">\u4e3b \u5367<\/td><td>26 \u33a1<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5e38\u5f00<\/td><td>40\u578b\uff081\u53f0\uff09<\/td><td>\u7761\u7720\u533a\uff0c\u8212\u9002\u4f18\u5148<\/td><\/tr>\n      <tr><td class=\"tl\">\u6b21 \u5367 A<\/td><td>20 \u33a1<\/td><td>\u2b50\u2b50\u2b50 \u6309\u9700\u5f00<\/td><td>32\u578b\uff081\u53f0\uff09<\/td><td>\u5bb6\u4eba\/\u5ba2\u623f<\/td><\/tr>\n      <tr><td class=\"tl\">\u6b21 \u5367 B<\/td><td>12 \u33a1<\/td><td>\u2b50\u2b50 \u5076\u5c14\u5f00<\/td><td>22\u578b\uff081\u53f0\uff09<\/td><td>\u5c0f\u5b69\/\u5907\u7528\u623f<\/td><\/tr>\n      <tr><td class=\"tl\">\u5168\u5c4b\u65b0\u98ce<\/td><td>133 \u33a1<\/td><td>\u2b50\u2b50\u2b50\u2b50\u2b50 \u5168\u5929\u8fd0\u884c<\/td><td>\u5929\u51c0\u65b0\u98ce350\uff081\u53f0\uff09<\/td><td>\u53cc\u5411\u5168\u70ed\u4ea4\u6362\uff0cPM2.5\u226598%<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- 02 \u65b9\u6848\u914d\u7f6e\u603b\u89c8 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">02<\/div>\n    <div><div class=\"sec-ttl\">\u4e24\u5927\u65b9\u6848\u914d\u7f6e\u603b\u89c8<\/div><div class=\"sec-desc\">\u7cfb\u7edf\u67b6\u6784 \u00b7 \u6838\u5fc3\u4ea7\u54c1 \u00b7 \u4e94\u6052\u80fd\u529b<\/div><\/div>\n  <\/div>\n  <div class=\"cards\">\n    <div class=\"card ca\">\n      <div class=\"badge badge-a\">\u65b9\u6848 A<\/div>\n      <div style=\"font-size:16px;font-weight:800;margin-bottom:4px;\">\u65e5\u7acb\u65b0\u667a\u4eab\u00b7\u5929\u6c1f\u5730\u6c34\u4e8c\u8054\u4f9b + \u5929\u51c0\u65b0\u98ce<\/div>\n      <div style=\"font-size:12px;color:var(--sub);margin-bottom:16px;\">SET-FREE \u667a\u4eab\u7cfb\u5217 \u00b7 Min\u6807\u51c6\u5185\u673a\uff08\u4e24\u7ba1\u5236\uff09+ \u5929\u51c0\u65b0\u98ce350<\/div>\n      <ul class=\"feat-list\">\n        <li>\ud83d\udd35 \u5916\u673a\uff1aRAS-160FSPUNAQ\uff08160\u5339\uff0c\u65b0\u667a\u4eab\u4e00\u4f53\u673a\uff0c\u5185\u542b\u6c34\u6a21\u5757\uff09<\/li>\n        <li>\ud83d\udd35 \u5185\u673a\uff1aMin \u7cfb\u5217 DC \u4e24\u7ba1\u5236\u6807\u51c6\u5185\u673a\uff08\u51715\u53f0\uff09<\/li>\n        <li>\ud83d\udd35 \u7cfb\u7edf\uff1a\u5929\u6c1f\u5730\u6c34\uff0c\u5236\u51b7\u4fa7\u6c1f\u5229\u6602\u76f4\u51b7\uff0c\u5730\u6696\u4fa7\u6c34\u6362\u70ed<\/li>\n        <li>\ud83d\udd35 \u65b0\u98ce\uff1a\u5929\u51c0\u65b0\u98ce350\uff0c\u5168\u70ed\u4ea4\u636280%\uff0cPM2.5\u51c0\u5316\u226598%<\/li>\n        <li>\ud83d\udd35 \u5730\u6696\uff1a133\u33a1 \u5168\u5c4b\u5730\u6696\u94fa\u8bbe\uff0c\u542b\u7ba1\u6750\/\u8f85\u6750\/\u65bd\u5de5<\/li>\n        <li>\ud83d\udd35 \u529f\u80fd\uff1a\u8d85\u4f4e\u6e29\u9664\u6e7f\uff08\u9664\u6e7f\u4e0d\u964d\u6e29\uff09\u3001PE\u51c0\u5316\u30015G\u7269\u8054<\/li>\n        <li>\ud83d\udd35 \u80fd\u6548\uff1aAPF 4.80~5.30 \u4e00\u7ea7\u80fd\u6548<\/li>\n        <li>\ud83d\udd35 \u5b9a\u4f4d\uff1a\u9ad8\u6027\u4ef7\u6bd4\u51b7\u6696+\u5730\u6696+\u65b0\u98ce\u5168\u80fd\u65b9\u6848<\/li>\n      <\/ul>\n      <a href=\"https:\/\/longmai-nt.com\/guide\/zhixiang.html\" class=\"src-link la\" target=\"_blank\">\ud83d\udd17 \u65b0\u667a\u4eab\u8be6\u60c5<\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" class=\"src-link la\" target=\"_blank\" style=\"margin-left:6px;\">\ud83d\udd17 \u5929\u51c0\u65b0\u98ce\u8be6\u60c5<\/a>\n    <\/div>\n    <div class=\"card cb\">\n      <div class=\"badge badge-b\">\u65b9\u6848 B<\/div>\n      <div style=\"font-size:16px;font-weight:800;margin-bottom:4px;\">\u65e5\u7acb\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf <span class=\"five-const\">\u4e94\u6052\u207a<\/span><\/div>\n      <div style=\"font-size:12px;color:var(--sub);margin-bottom:16px;\">\u5c0a\u777f\u5168\u6548II + \u6c34\u6a21\u5757 + \u4e09\u7ba1\u5236\u51c0\u5316\u5185\u673a + \u5929\u51c0\u65b0\u98ce350 + \u96c6\u63a7\u5c4f<\/div>\n      <ul class=\"feat-list\">\n        <li>\ud83d\udfe3 \u5916\u673a\uff1aRAS-160FSXPN5Q\uff08\u5c0a\u777f\u5168\u6548II\uff0c160\u5339\uff09<\/li>\n        <li>\ud83d\udfe3 \u6c34\u6a21\uff1aRWMG-160FWXNZQ\uff08\u5c0a\u777f\u4e13\u7528\u6c34\u6a21\u5757\uff09<\/li>\n        <li>\ud83d\udfe3 \u5185\u673a\uff1a\u4e09\u7ba1\u5236\u5168\u6548\u51c0\u5316\u5185\u673a RPIZ-FSVN2QB\/PC\uff08\u51715\u53f0\uff09<\/li>\n        <li>\ud83d\udfe3 \u65b0\u98ce\uff1a\u5929\u51c0\u65b0\u98ce350\uff0c\u53cc\u5411\u5168\u70ed\u4ea4\u6362\u6052\u6c27\u6052\u51c0<\/li>\n        <li>\ud83d\udfe3 \u5730\u6696\uff1a133\u33a1 \u5168\u5c4b\u5730\u6696\u94fa\u8bbe\uff0c\u542b\u7ba1\u6750\/\u8f85\u6750\/\u65bd\u5de5<\/li>\n        <li>\ud83d\udfe3 \u7cfb\u7edf\uff1a\u884c\u4e1a\u552f\u4e00\u4e09\u7ba1\u5236 + \u96c6\u63a7\u5c4f\u8054\u52a8 = <strong>\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf<\/strong><\/li>\n        <li>\ud83d\udfe3 \u529f\u80fd\uff1aPE\u207a\u5168\u98ce\u8def\u51c0\u5316\u8231\u3001\u5b8c\u5168\u72ec\u7acb\u9664\u6e7f\u3001\u4e94\u6052\u96c6\u63a7\u8054\u52a8<\/li>\n        <li>\ud83d\udfe3 \u80fd\u6548\uff1aAPF 5.20~6.20 \u4e00\u7ea7\u80fd\u6548\uff08\u66f4\u7701\u7535\uff09<\/li>\n        <li>\ud83d\udfe3 \u5b9a\u4f4d\uff1a\u65e5\u7acb\u65d7\u8230\u7ea7\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759\u5168\u6548\u7cfb\u7edf<\/li>\n      <\/ul>\n      <a href=\"https:\/\/longmai-nt.com\/guide\/zunrui-shuimokuai.html\" class=\"src-link lb\" target=\"_blank\">\ud83d\udd17 \u5c0a\u777f\u6c34\u6a21\u5757\u8be6\u60c5<\/a>\n      <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" class=\"src-link lb\" target=\"_blank\" style=\"margin-left:6px;\">\ud83d\udd17 \u5929\u51c0\u65b0\u98ce\u8be6\u60c5<\/a>\n    <\/div>\n  <\/div>\n  <div class=\"notice\">\n    <strong>\ud83d\udca1 \u62a5\u4ef7\u8bf4\u660e\uff1a<\/strong>\u7a7a\u8c03\u8bbe\u5907\u62a5\u4ef7\u4ee5\u9f99\u8109\u5b98\u7f51\u9762\u4ef7 \u00d7 <strong>8.5\u6298<\/strong> \u4e3a\u6210\u4ea4\u4ef7\uff1b\u5b89\u88c5\u8d39\u6309\u4e1a\u4e3b\u786e\u8ba4\u89c4\u5219\u6267\u884c\uff08\u5916\u673a600\u5143\/\u53f0\uff0c\u5185\u673a\u65b9\u6848A 1750\u5143\/\u53f0\u3001\u65b9\u6848B 1900\u5143\/\u53f0\uff09\u3002<strong>\u5730\u6696\u90e8\u5206\u6309133\u33a1 \u00d7 179\u5143\/\u33a1\u7efc\u5408\u62a5\u4ef7<\/strong>\uff08\u542b\u7ba1\u6750\u3001\u8f85\u6750\u3001\u5206\u96c6\u6c34\u5668\u3001\u65bd\u5de5\uff09\u3002<strong>\u5929\u51c0\u65b0\u98ce350\u6309\u4ef7\u683c\u6307\u4ee4\u76f4\u63a5\u62a5\u4ef7<\/strong>\uff08\u8bbe\u59079,500\u5143 + \u5b89\u88c56,200\u5143 = 15,700\u5143\uff09\u3002\u65b9\u6848B\u52a0\u96c6\u63a7\u5c4f\u5b9e\u73b0\u4e94\u6052\u8054\u52a8\uff0c\u96c6\u63a7\u5c4f\u8d39\u7528\u542b\u5728\u7cfb\u7edf\u914d\u7f6e\u4e2d\u3002\n  <\/div>\n  <div class=\"formula\">\n    \u6298\u540e\u4ef7 = \u9762\u4ef7 \u00d7 0.85\u3000|\u3000\u5b9e\u4ed8 = \u6298\u540e\u4ef7 + \u5b89\u88c5\u8d39 + \u5730\u6696 + \u65b0\u98ce\u3000|\u3000\u6570\u636e\u6765\u6e90\uff1a\u9f99\u8109\u6696\u901a\u4ef7\u683c\u6307\u4ee4 V5.0\uff082026.5.23\uff09\n  <\/div>\n<\/div>\n\n<!-- 03 \u65b9\u6848A\u8be6\u7ec6\u62a5\u4ef7 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">03<\/div>\n    <div><div class=\"sec-ttl\">\u65b9\u6848 A \u00b7 \u65b0\u667a\u4eab\u8be6\u7ec6\u62a5\u4ef7<\/div><div class=\"sec-desc\">\u65b0\u667a\u4eab RAS-160FSPUNAQ + Min\u6807\u51c6\u5185\u673a \u00d7 5\u53f0 + \u5929\u51c0\u65b0\u98ce350 + \u5730\u6696<\/div><\/div>\n  <\/div>\n  <table>\n    <thead class=\"hd-a\">\n      <tr><th>\u8bbe\u5907\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7\uff08\u5143\uff09<\/th><th>\u6298\u540e\u4ef7\uff08\u5143\uff09<\/th><th>\u5b89\u88c5\u8d39\uff08\u5143\uff09<\/th><th>\u5c0f\u8ba1\uff08\u5143\uff09<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"tl\">\u65b0\u667a\u4eab\u5916\u673a<span class=\"ts\">\u542b\u6c34\u6a21\u5757\/160\u5339<\/span><\/td>\n        <td class=\"pn\">RAS-160FSPUNAQ<\/td>\n        <td>1\u53f0<\/td>\n        <td>25,225<\/td>\n        <td class=\"ta\">21,441<\/td>\n        <td>600<\/td>\n        <td class=\"ta\">22,041<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">Min\u5185\u673a\u00b771\u578b<span class=\"ts\">\u5ba2\u9910\u5385\u533a<\/span><\/td>\n        <td class=\"pn\">RPIZ-63~71FSVNZ1QD\/P<\/td>\n        <td>1\u53f0<\/td>\n        <td>4,963<\/td>\n        <td class=\"ta\">4,219<\/td>\n        <td>1,750<\/td>\n        <td class=\"ta\">5,969<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">Min\u5185\u673a\u00b732\u578b<span class=\"ts\">\u5f00\u653e\u4e66\u623f\u533a<\/span><\/td>\n        <td class=\"pn\">RPIZ-32~40FSVNZ1QD\/P<\/td>\n        <td>1\u53f0<\/td>\n        <td>4,513<\/td>\n        <td class=\"ta\">3,836<\/td>\n        <td>1,750<\/td>\n        <td class=\"ta\">5,586<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">Min\u5185\u673a\u00b740\u578b<span class=\"ts\">\u4e3b\u5367<\/span><\/td>\n        <td class=\"pn\">RPIZ-32~40FSVNZ1QD\/P<\/td>\n        <td>1\u53f0<\/td>\n        <td>4,513<\/td>\n        <td class=\"ta\">3,836<\/td>\n        <td>1,750<\/td>\n        <td class=\"ta\">5,586<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">Min\u5185\u673a\u00b732\u578b<span class=\"ts\">\u6b21\u5367A\uff0820\u33a1\uff09<\/span><\/td>\n        <td class=\"pn\">RPIZ-32~40FSVNZ1QD\/P<\/td>\n        <td>1\u53f0<\/td>\n        <td>4,513<\/td>\n        <td class=\"ta\">3,836<\/td>\n        <td>1,750<\/td>\n        <td class=\"ta\">5,586<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">Min\u5185\u673a\u00b722\u578b<span class=\"ts\">\u6b21\u5367B\uff0812\u33a1\uff09<\/span><\/td>\n        <td class=\"pn\">RPIZ-22~28FSVNZ1QD\/P<\/td>\n        <td>1\u53f0<\/td>\n        <td>4,313<\/td>\n        <td class=\"ta\">3,666<\/td>\n        <td>1,750<\/td>\n        <td class=\"ta\">5,416<\/td>\n      <\/tr>\n      <tr class=\"row-sub\">\n        <td colspan=\"3\" class=\"tl\">\ud83d\udd38 \u7a7a\u8c03\u8bbe\u5907\u6298\u540e\u5408\u8ba1 \/ \u5b89\u88c5\u8d39\u5408\u8ba1<\/td>\n        <td><span style=\"color:var(--sub);font-weight:400;\">\u9762\u4ef7\u5408\u8ba1\uff1a48,034<\/span><\/td>\n        <td class=\"ta\">40,834<\/td>\n        <td class=\"ta\">9,350<\/td>\n        <td class=\"ta\">50,184<\/td>\n      <\/tr>\n      <tr class=\"row-add\">\n        <td class=\"tl\">\u5730\u6696\u94fa\u8bbe<span class=\"ts\">133\u33a1 \u00d7 179\u5143\/\u33a1<\/span><\/td>\n        <td class=\"pn\">\u2014<\/td>\n        <td>133\u33a1<\/td>\n        <td>\u2014<\/td>\n        <td>\u2014<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">\u542b\u7ba1\u6750\/\u8f85\u6750\/\u65bd\u5de5<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">23,807<\/td>\n      <\/tr>\n      <tr class=\"row-add\">\n        <td class=\"tl\">\u5929\u51c0\u65b0\u98ce350<span class=\"ts\">\u5168\u70ed\u4ea4\u6362 350m\u00b3\/h<\/span><\/td>\n        <td class=\"pn\">KPI-3521Q5\/F<\/td>\n        <td>1\u53f0<\/td>\n        <td>9,500<\/td>\n        <td style=\"color:var(--sub);font-weight:400;\">\u4ef7\u683c\u6307\u4ee4\u76f4\u62a5<\/td>\n        <td>6,200<\/td>\n        <td class=\"ta\">15,700<\/td>\n      <\/tr>\n      <tr class=\"row-total\">\n        <td colspan=\"3\" class=\"tl\">\ud83d\udd36 \u65b9\u6848 A \u603b\u8ba1<\/td>\n        <td><\/td>\n        <td><\/td>\n        <td><\/td>\n        <td class=\"ta\" style=\"font-size:18px;\">89,691 \u5143<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"notice\">\n    <strong>\u26a0\ufe0f \u578b\u53f7\u8bf4\u660e\uff1a<\/strong>\u65b0\u667a\u4eab\uff08\u667a\u4eab\u7cfb\u5217\uff09160\u5339\u5916\u673a\u5b98\u65b9\u578b\u53f7\u4e3a <strong>RAS-160FSPUNAQ<\/strong>\uff0c\u9762\u4ef725,225\u5143\uff0c\u5b89\u88c5\u8d39\u5728\u9762\u4ef7\u4e2d\u5df2\u6807\u6ce8\"\u2014\"\uff08\u542b\u5728\u9762\u4ef7\u5185\uff09\u4f46\u672c\u65b9\u6848\u6309\u4e1a\u4e3b\u7ea6\u5b9a\u53e6\u8ba1600\u5143\uff1b\u914d\u5957 Min \u6807\u51c6\u5185\u673a\u91c7\u7528\"\u5c0a\u777f\u667a\u4eab\u5171\u7528\u5185\u673a DC\u4e24\u7ba1\u5236\u6807\u51c6\"\u7cfb\u5217\uff0c32\u578b\u4e0e40\u578b\u5171\u7528\u540c\u4e00\u4ef7\u683c\u6863\uff08RPIZ-32~40\uff09\uff0c\u9762\u4ef74,513\u5143\u3002\u5929\u51c0\u65b0\u98ce350\u4ef7\u683c\u6309\u4ef7\u683c\u6307\u4ee4\u76f4\u63a5\u62a5\u4ef7\uff0c\u4e0d\u9002\u75288.5\u6298\u3002\n  <\/div>\n<\/div>\n\n<!-- 04 \u65b9\u6848B\u8be6\u7ec6\u62a5\u4ef7 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">04<\/div>\n    <div><div class=\"sec-ttl\">\u65b9\u6848 B \u00b7 \u5c0a\u777f\u5168\u6548\u4e94\u6052\u7cfb\u7edf\u8be6\u7ec6\u62a5\u4ef7<\/div><div class=\"sec-desc\">\u5c0a\u777f\u5168\u6548II + \u6c34\u6a21\u5757 + \u4e09\u7ba1\u5236\u5185\u673a \u00d7 5\u53f0 + \u5929\u51c0\u65b0\u98ce350 + \u96c6\u63a7\u5c4f + \u5730\u6696<\/div><\/div>\n  <\/div>\n  <table>\n    <thead class=\"hd-b\">\n      <tr><th>\u8bbe\u5907\u9879\u76ee<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7\uff08\u5143\uff09<\/th><th>\u6298\u540e\u4ef7\uff08\u5143\uff09<\/th><th>\u5b89\u88c5\u8d39\uff08\u5143\uff09<\/th><th>\u5c0f\u8ba1\uff08\u5143\uff09<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"tl\">\u5c0a\u777f\u5168\u6548II\u5916\u673a<span class=\"ts\">160\u5339<\/span><\/td>\n        <td class=\"pn\">RAS-160FSXPN5Q<\/td>\n        <td>1\u53f0<\/td>\n        <td>20,600<\/td>\n        <td class=\"tb\">17,510<\/td>\n        <td>600<\/td>\n        <td class=\"tb\">18,110<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u5c0a\u777f\u4e13\u7528\u6c34\u6a21\u5757<span class=\"ts\">160\u5339\u914d\u5957<\/span><\/td>\n        <td class=\"pn\">RWMG-160FWXNZQ<\/td>\n        <td>1\u5957<\/td>\n        <td>8,375<\/td>\n        <td class=\"tb\">7,119<\/td>\n        <td>625<\/td>\n        <td class=\"tb\">7,744<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u4e09\u7ba1\u5236\u5185\u673a\u00b771\u578b<span class=\"ts\">\u5ba2\u9910\u5385\u533a<\/span><\/td>\n        <td class=\"pn\">RPIZ-63~71FSVN2QB\/PC<\/td>\n        <td>1\u53f0<\/td>\n        <td>5,825<\/td>\n        <td class=\"tb\">4,951<\/td>\n        <td>1,900<\/td>\n        <td class=\"tb\">6,851<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u4e09\u7ba1\u5236\u5185\u673a\u00b732\u578b<span class=\"ts\">\u5f00\u653e\u4e66\u623f\u533a<\/span><\/td>\n        <td class=\"pn\">RPIZ-32~40FSVN2QB\/PC<\/td>\n        <td>1\u53f0<\/td>\n        <td>5,238<\/td>\n        <td class=\"tb\">4,452<\/td>\n        <td>1,900<\/td>\n        <td class=\"tb\">6,352<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u4e09\u7ba1\u5236\u5185\u673a\u00b740\u578b<span class=\"ts\">\u4e3b\u5367<\/span><\/td>\n        <td class=\"pn\">RPIZ-32~40FSVN2QB\/PC<\/td>\n        <td>1\u53f0<\/td>\n        <td>5,238<\/td>\n        <td class=\"tb\">4,452<\/td>\n        <td>1,900<\/td>\n        <td class=\"tb\">6,352<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u4e09\u7ba1\u5236\u5185\u673a\u00b732\u578b<span class=\"ts\">\u6b21\u5367A\uff0820\u33a1\uff09<\/span><\/td>\n        <td class=\"pn\">RPIZ-32~40FSVN2QB\/PC<\/td>\n        <td>1\u53f0<\/td>\n        <td>5,238<\/td>\n        <td class=\"tb\">4,452<\/td>\n        <td>1,900<\/td>\n        <td class=\"tb\">6,352<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u4e09\u7ba1\u5236\u5185\u673a\u00b722\u578b<span class=\"ts\">\u6b21\u5367B\uff0812\u33a1\uff09<\/span><\/td>\n        <td class=\"pn\">RPIZ-18~22FSVN2QB\/PC<\/td>\n        <td>1\u53f0<\/td>\n        <td>5,050<\/td>\n        <td class=\"tb\">4,293<\/td>\n        <td>1,900<\/td>\n        <td class=\"tb\">6,193<\/td>\n      <\/tr>\n      <tr class=\"row-sub\">\n        <td colspan=\"3\" class=\"tl\">\ud83d\udd38 \u7a7a\u8c03\u8bbe\u5907\u6298\u540e\u5408\u8ba1 \/ \u5b89\u88c5\u8d39\u5408\u8ba1<\/td>\n        <td><span style=\"color:var(--sub);font-weight:400;\">\u9762\u4ef7\u5408\u8ba1\uff1a55,564<\/span><\/td>\n        <td class=\"tb\">47,229<\/td>\n        <td class=\"tb\">11,525<\/td>\n        <td class=\"tb\">58,754<\/td>\n      <\/tr>\n      <tr class=\"row-add\">\n        <td class=\"tl\">\u5730\u6696\u94fa\u8bbe<span class=\"ts\">133\u33a1 \u00d7 179\u5143\/\u33a1<\/span><\/td>\n        <td class=\"pn\">\u2014<\/td>\n        <td>133\u33a1<\/td>\n        <td>\u2014<\/td>\n        <td>\u2014<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">\u542b\u7ba1\u6750\/\u8f85\u6750\/\u65bd\u5de5<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">23,807<\/td>\n      <\/tr>\n      <tr class=\"row-add\">\n        <td class=\"tl\">\u5929\u51c0\u65b0\u98ce350<span class=\"ts\">\u5168\u70ed\u4ea4\u6362 350m\u00b3\/h<\/span><\/td>\n        <td class=\"pn\">KPI-3521Q5\/F<\/td>\n        <td>1\u53f0<\/td>\n        <td>9,500<\/td>\n        <td style=\"color:var(--sub);font-weight:400;\">\u4ef7\u683c\u6307\u4ee4\u76f4\u62a5<\/td>\n        <td>6,200<\/td>\n        <td class=\"tb\">15,700<\/td>\n      <\/tr>\n      <tr class=\"row-add\">\n        <td class=\"tl\">\u4e94\u6052\u96c6\u63a7\u5c4f<span class=\"ts\">\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u8054\u52a8\u63a7\u5236<\/span><\/td>\n        <td class=\"pn\">\u65e5\u7acb\u5168\u5c4b\u5168\u611f\u96c6\u63a7\u5c4f<\/td>\n        <td>1\u5957<\/td>\n        <td colspan=\"4\" style=\"color:var(--sub);font-weight:400;\">\u542b\u5728\u4e94\u6052\u7cfb\u7edf\u914d\u7f6e\u4e2d\uff0c\u5b9e\u73b0\u6e29\u6e7f\u5ea6\/\u7a7a\u6c14\/\u8bbe\u5907\u96c6\u4e2d\u667a\u63a7<\/td>\n        <td class=\"tb\">\u542b\u4e8e\u7cfb\u7edf<\/td>\n      <\/tr>\n      <tr class=\"row-total\">\n        <td colspan=\"3\" class=\"tl\">\ud83d\udd36 \u65b9\u6848 B \u603b\u8ba1\uff08\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf\uff09<\/td>\n        <td><\/td>\n        <td><\/td>\n        <td><\/td>\n        <td class=\"tb\" style=\"font-size:18px;\">98,261 \u5143<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n  <div class=\"notice\">\n    <strong>\u26a0\ufe0f \u578b\u53f7\u8bf4\u660e\uff1a<\/strong>\u5c0a\u777f\u5168\u6548II 160\u5339\u5916\u673a\u578b\u53f7 <strong>RAS-160FSXPN5Q<\/strong>\uff0c\u9762\u4ef720,600\u5143\uff1b\u4e13\u7528\u6c34\u6a21\u5757 <strong>RWMG-160FWXNZQ<\/strong>\uff0c\u9762\u4ef78,375\u5143\uff0c\u5b89\u88c5\u8d39625\u5143\uff08\u5b98\u65b9\u4ef7\u683c\u8868\u89c4\u5219\uff09\uff1b\u4e09\u7ba1\u5236\u5185\u673a22\u578b\u4ef7\u683c\u6863\u4e3a RPIZ-18~22\uff0c\u9762\u4ef75,050\u5143\uff1b32\u578b\u4e0e40\u578b\u540c\u4ef7\u6863\uff0c\u9762\u4ef75,238\u5143\uff1b71\u578b\u9762\u4ef75,825\u5143\u3002\u65b9\u6848B\u901a\u8fc7\u5c0a\u777f\u5168\u6548\u4e3b\u673a + \u5929\u51c0\u65b0\u98ce + \u96c6\u63a7\u5c4f\u5b9e\u73b0\u65e5\u7acb\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf\uff08\u6052\u6e29\u00b7\u6052\u6e7f\u00b7\u6052\u6c27\u00b7\u6052\u6d01\u00b7\u6052\u9759\uff09\u3002\n  <\/div>\n<\/div>\n\n<!-- 05 \u603b\u4ef7\u6c47\u603b -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">05<\/div>\n    <div><div class=\"sec-ttl\">\u4e24\u65b9\u6848\u603b\u4ef7\u6c47\u603b\u5bf9\u6bd4<\/div><div class=\"sec-desc\">\u7a7a\u8c03\u8bbe\u5907+\u5730\u6696+\u65b0\u98ce \u00b7 \u5b8c\u6574\u62a5\u4ef7<\/div><\/div>\n  <\/div>\n  <table>\n    <thead class=\"hd-gold\">\n      <tr><th>\u62a5\u4ef7\u9879\u76ee<\/th><th>\u65b9\u6848 A \u00b7 \u65b0\u667a\u4eab + \u65b0\u98ce<\/th><th>\u65b9\u6848 B \u00b7 \u5c0a\u777f\u5168\u6548\u4e94\u6052\u7cfb\u7edf<\/th><th>\u5dee\u5f02\u8bf4\u660e<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"tl\">\u5916\u673a\u6298\u540e\u4ef7<\/td>\n        <td class=\"ta\">21,441 \u5143<\/td>\n        <td class=\"tb\">17,510 \u5143<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u5916\u673a\u9762\u4ef7\u66f4\u4f4e\uff0c\u4f46\u9700\u989d\u5916\u52a0\u6c34\u6a21\u5757<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u6c34\u6a21\u5757\u6298\u540e\u4ef7<\/td>\n        <td style=\"color:var(--sub);\">\u5df2\u542b\u5728\u5916\u673a\u5185<\/td>\n        <td class=\"tb\">7,119 \u5143<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u6c34\u6a21\u5757\u5355\u72ec\u8ba1\u7b97<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u5916\u673a + \u6c34\u6a21\u5757\u6298\u540e\u5408\u8ba1<\/td>\n        <td class=\"ta\">21,441 \u5143<\/td>\n        <td class=\"tb\">24,629 \u5143<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u4e3b\u673a\u4fa7\u5408\u8ba1\u591a 3,188 \u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u5916\u673a\/\u6c34\u6a21\u5b89\u88c5\u8d39<\/td>\n        <td class=\"ta\">600 \u5143<\/td>\n        <td class=\"tb\">1,225 \u5143\uff08600+625\uff09<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u591a 625 \u5143\uff08\u6c34\u6a21\u5757\u5b89\u88c5\uff09<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u5185\u673a\u6298\u540e\u4ef7\u5408\u8ba1\uff085\u53f0\uff09<\/td>\n        <td class=\"ta\">19,393 \u5143<\/td>\n        <td class=\"tb\">22,600 \u5143<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u4e09\u7ba1\u5236\u5185\u673a\u5355\u4ef7\u66f4\u9ad8\uff0c\u591a 3,207 \u5143<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\u5185\u673a\u5b89\u88c5\u8d39\u5408\u8ba1\uff085\u53f0\uff09<\/td>\n        <td class=\"ta\">8,750 \u5143<\/td>\n        <td class=\"tb\">9,500 \u5143<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u5b89\u88c5\u8d39 1900 vs 1750\uff0c\u591a 750 \u5143<\/td>\n      <\/tr>\n      <tr class=\"row-sub\">\n        <td class=\"tl\">\ud83d\udd38 \u7a7a\u8c03\u8bbe\u5907\u6298\u540e\u4ef7\u5408\u8ba1<\/td>\n        <td class=\"ta\">40,834 \u5143<\/td>\n        <td class=\"tb\">47,229 \u5143<\/td>\n        <td style=\"font-weight:700;color:#b34000;\">+6,395 \u5143<\/td>\n      <\/tr>\n      <tr class=\"row-sub\">\n        <td class=\"tl\">\ud83d\udd38 \u7a7a\u8c03\u5b89\u88c5\u8d39\u5408\u8ba1<\/td>\n        <td class=\"ta\">9,350 \u5143<\/td>\n        <td class=\"tb\">11,525 \u5143<\/td>\n        <td style=\"font-weight:700;color:#b34000;\">+2,175 \u5143<\/td>\n      <\/tr>\n      <tr class=\"row-sub\">\n        <td class=\"tl\">\ud83d\udd38 \u7a7a\u8c03\u90e8\u5206\u5c0f\u8ba1<\/td>\n        <td class=\"ta\">50,184 \u5143<\/td>\n        <td class=\"tb\">58,754 \u5143<\/td>\n        <td style=\"font-weight:700;color:#b34000;\">+8,570 \u5143<\/td>\n      <\/tr>\n      <tr style=\"background:#FFF8E1;\">\n        <td class=\"tl\">\u5730\u6696\u94fa\u8bbe\uff08133\u33a1 \u00d7 179\u5143\/\u33a1\uff09<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">23,807 \u5143<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">23,807 \u5143<\/td>\n        <td class=\"td-note\">\u4e24\u65b9\u6848\u76f8\u540c\uff0c\u542b\u7ba1\u6750\/\u8f85\u6750\/\u65bd\u5de5<\/td>\n      <\/tr>\n      <tr style=\"background:#FFF8E1;\">\n        <td class=\"tl\">\u5929\u51c0\u65b0\u98ce350\uff08\u8bbe\u5907+\u5b89\u88c5\uff09<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">15,700 \u5143<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">15,700 \u5143<\/td>\n        <td class=\"td-note\">\u4e24\u65b9\u6848\u76f8\u540c\uff0c\u4ef7\u683c\u6307\u4ee4\u76f4\u62a5<\/td>\n      <\/tr>\n      <tr style=\"background:#FFF8E1;\">\n        <td class=\"tl\">\u4e94\u6052\u96c6\u63a7\u5c4f<\/td>\n        <td style=\"color:var(--sub);\">\u2014<\/td>\n        <td style=\"color:#7a5010;font-weight:700;\">\u542b\u4e8e\u7cfb\u7edf<\/td>\n        <td class=\"td-note\">\u65b9\u6848B\u72ec\u6709\uff0c\u542b\u5728\u4e94\u6052\u7cfb\u7edf\u914d\u7f6e\u4e2d<\/td>\n      <\/tr>\n      <tr class=\"row-total\">\n        <td class=\"tl\">\ud83d\udd36 \u65b9\u6848\u603b\u4ef7\uff08\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\uff09<\/td>\n        <td class=\"ta\" style=\"font-size:16px;\">89,691 \u5143<\/td>\n        <td class=\"tb\" style=\"font-size:16px;\">98,261 \u5143<\/td>\n        <td style=\"color:#FFCC80;font-weight:800;\">\u5dee\u4ef7 +8,570 \u5143<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n\n  <div class=\"cards\">\n    <div class=\"card ca\" style=\"text-align:center;\">\n      <div class=\"badge badge-a\">\u65b9\u6848 A \u603b\u4ef7\uff08\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\uff09<\/div>\n      <div class=\"price-big a\">89,691 \u5143<\/div>\n      <div class=\"price-label\">\u7a7a\u8c03 50,184 + \u5730\u6696 23,807 + \u65b0\u98ce 15,700<\/div>\n    <\/div>\n    <div class=\"card cb\" style=\"text-align:center;\">\n      <div class=\"badge badge-b\">\u65b9\u6848 B \u603b\u4ef7\uff08\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf\uff09<\/div>\n      <div class=\"price-big b\">98,261 \u5143<\/div>\n      <div class=\"price-label\">\u7a7a\u8c03 58,754 + \u5730\u6696 23,807 + \u65b0\u98ce 15,700<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"notice notice-red\">\n    <strong>\ud83d\udccc \u91cd\u8981\u8bf4\u660e\uff1a<\/strong>\u7a7a\u8c03\u5b89\u88c5\u8d39\u5df2\u542b\u8f85\u6750\uff08\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u7ebf\u7f06\u7b49\uff09\u3002\u5730\u6696\u90e8\u5206179\u5143\/\u33a1\u4e3a\u7efc\u5408\u62a5\u4ef7\uff0c\u542b\u7ba1\u6750\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u5206\u96c6\u6c34\u5668\u53ca\u65bd\u5de5\u94fa\u8bbe\u3002\u5929\u51c0\u65b0\u98ce350\u8bbe\u59079,500\u5143 + \u5b89\u88c56,200\u5143\u4e3a\u4ef7\u683c\u6307\u4ee4\u76f4\u62a5\u4ef7\u683c\uff0c\u4e0d\u9002\u75288.5\u6298\u3002\u65b9\u6848B\u7684\u96c6\u63a7\u5c4f\u542b\u5728\u4e94\u6052\u7cfb\u7edf\u6574\u4f53\u914d\u7f6e\u4e2d\u3002\u6700\u7ec8\u4ee5\u6b63\u5f0f\u62a5\u4ef7\u5355\u53ca\u5408\u540c\u4e3a\u51c6\u3002\n  <\/div>\n<\/div>\n\n<!-- 06 \u516d\u7ef4\u6027\u80fd\u5bf9\u6bd4 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">06<\/div>\n    <div><div class=\"sec-ttl\">\u516d\u7ef4\u6027\u80fd\u96f7\u8fbe\u5bf9\u6bd4<\/div><div class=\"sec-desc\">\u57fa\u4e8e\u6c88\u5c0f\u59d0\u5bb6\u5ead\u4f7f\u7528\u573a\u666f\u7684\u7efc\u5408\u8bc4\u5206\uff08\u542b\u65b0\u98ce\u7cfb\u7edf\uff09<\/div><\/div>\n  <\/div>\n  <div class=\"radar-box\">\n    <div style=\"text-align:center;font-size:15px;font-weight:800;color:var(--dark);margin-bottom:20px;\">\u65b9\u6848A\uff08\u65b0\u667a\u4eab+\u65b0\u98ce\uff09vs \u65b9\u6848B\uff08\u5c0a\u777f\u5168\u6548\u4e94\u6052\uff09\u2014 \u7efc\u5408\u6027\u80fd\u8bc4\u4f30<\/div>\n    <canvas id=\"radar\" width=\"520\" height=\"400\"><\/canvas>\n    <div style=\"display:flex;justify-content:center;gap:30px;margin-top:16px;font-size:12px;\">\n      <span style=\"display:flex;align-items:center;gap:6px;\"><span style=\"width:18px;height:3px;background:var(--plan-a);display:inline-block;border-radius:2px;\"><\/span>\u65b9\u6848A \u00b7 \u65b0\u667a\u4eab+\u65b0\u98ce<\/span>\n      <span style=\"display:flex;align-items:center;gap:6px;\"><span style=\"width:18px;height:3px;background:var(--plan-b);display:inline-block;border-radius:2px;\"><\/span>\u65b9\u6848B \u00b7 \u4e94\u6052\u7cfb\u7edf<\/span>\n    <\/div>\n  <\/div>\n  <table>\n    <thead class=\"hd-dark\">\n      <tr><th>\u8bc4\u4f30\u7ef4\u5ea6<\/th><th>\u65b9\u6848 A \u00b7 \u65b0\u667a\u4eab+\u65b0\u98ce<\/th><th>\u65b9\u6848 B \u00b7 \u4e94\u6052\u7cfb\u7edf<\/th><th>\u4f18\u52bf<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"tl\">\u26a1 \u5236\u51b7\u901f\u5ea6<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2605 \u6c1f\u5229\u6602\u76f4\u51b7\uff0c\u51fa\u98ce 7~12\u2103\uff0c\u54cd\u5e94\u6781\u5feb<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2606 \u5236\u51b7\u4ea6\u5feb\uff0c\u7565\u900a\u4e8e\u76f4\u51b7<\/td>\n        <td><span class=\"tag tag-g\">\u65b9\u6848A<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\ud83d\udca7 \u9664\u6e7f\u4f53\u9a8c<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2606 \u8d85\u4f4e\u6e29\u9664\u6e7f\uff0c\u57fa\u672c\u4e0d\u964d\u5ba4\u6e29<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2605 \u4e09\u7ba1\u5236\u5b8c\u5168\u72ec\u7acb\u9664\u6e7f\uff0c\u5ba4\u6e29\u96f6\u5f71\u54cd<\/td>\n        <td><span class=\"tag tag-g\">\u65b9\u6848B<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\ud83c\udf3f \u5065\u5eb7\u51c0\u5316\u00b7\u65b0\u98ce<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2606 PE\u51c0\u5316 + \u5929\u51c0\u65b0\u98ce350\u5168\u70ed\u4ea4\u6362<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2605 PE\u207a\u5168\u98ce\u8def\u51c0\u5316\u8231 + \u5929\u51c0\u65b0\u98ce350 + \u4e94\u6052\u8054\u52a8<\/td>\n        <td><span class=\"tag tag-g\">\u65b9\u6848B<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\ud83d\udcb0 \u6027\u4ef7\u6bd4<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2605 8.97\u4e07\uff0c\u51b7\u6696\u5730\u6696\u65b0\u98ce\u5168\u542b<\/td>\n        <td>\u2605\u2605\u2605\u2606\u2606 9.83\u4e07\uff0c\u4e94\u6052\u65d7\u8230\u7ea7\u65b9\u6848<\/td>\n        <td><span class=\"tag tag-g\">\u65b9\u6848A<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\ud83d\udd0b \u80fd\u6548\u6c34\u5e73<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2606 APF 4.80~5.30<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2605 APF 5.20~6.20\uff0c\u4e94\u6052\u667a\u63a7\u66f4\u7701\u7535<\/td>\n        <td><span class=\"tag tag-g\">\u65b9\u6848B<\/span><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"tl\">\ud83d\udce1 \u7cfb\u7edf\u62d3\u5c55\u00b7\u4e94\u6052<\/td>\n        <td>\u2605\u2605\u2605\u2606\u2606 \u5929\u51c0\u65b0\u98ce\u72ec\u7acb\u8fd0\u884c\uff0c\u7a7a\u8c03\u57fa\u7840\u62d3\u5c55<\/td>\n        <td>\u2605\u2605\u2605\u2605\u2605 \u5168\u5c4b\u5168\u611f\u4e94\u6052\u8054\u52a8\uff0c\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759<\/td>\n        <td><span class=\"tag tag-g\">\u65b9\u6848B<\/span><\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- 07 \u65b9\u6848\u6df1\u5ea6\u89e3\u6790 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">07<\/div>\n    <div><div class=\"sec-ttl\">\u65b9\u6848\u6df1\u5ea6\u89e3\u6790<\/div><div class=\"sec-desc\">\u7ed3\u5408\u6c88\u5c0f\u59d0\u5b9e\u9645\u9700\u6c42\u7684\u9488\u5bf9\u6027\u5206\u6790<\/div><\/div>\n  <\/div>\n  <div class=\"verdict va\">\n    <div class=\"verdict-ttl a\">\u2705 \u65b9\u6848 A \u00b7 \u65e5\u7acb\u65b0\u667a\u4eab\u300c\u5929\u6c1f\u5730\u6c34+\u65b0\u98ce\u300d\u2014\u2014 \u5168\u80fd\u6027\u4ef7\u6bd4\u9996\u9009<\/div>\n    <div class=\"verdict-body\">\n      <strong>\u2460 \u5236\u51b7\u5feb\uff0c\u5b8c\u5168\u5339\u914d\u6838\u5fc3\u8bc9\u6c42\uff1a<\/strong>\u5929\u6c1f\u5730\u6c34\u7cfb\u7edf\u7a7a\u8c03\u4fa7\u91c7\u7528\u6c1f\u5229\u6602\u76f4\u63a5\u6362\u70ed\uff0c\u51fa\u98ce\u6e29\u5ea67~12\u2103\uff0c\u964d\u6e29\u54cd\u5e94\u901f\u5ea6\u5feb\uff0c\u5bf9\u6bd4\u5927\u91d1\u540c\u7ea7\u65b9\u6848\u4e0d\u843d\u4e0b\u98ce\uff0c\u4e14\u5ba2\u9910\u538575\u33a1\u5927\u7a7a\u95f4\u914d\u7f6e71+32\u4e24\u53f0\u5185\u673a\uff0c\u5236\u51b7\u529b\u5ea6\u5145\u8db3\u3002<br><br>\n      <strong>\u2461 8.97\u4e07\u5168\u542b\uff0c\u6027\u4ef7\u6bd4\u7a81\u51fa\uff1a<\/strong>\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u5927\u7cfb\u7edf\u4e00\u6b65\u5230\u4f4d\u3002\u5927\u91d1\u540c\u7ea7\u4e8c\u8054\u4f9b+\u65b0\u98ce\u65b9\u6848\u901a\u5e38\u572810\u4e07+\u533a\u95f4\uff0c\u65b0\u667a\u4eab\u65b9\u6848\u4ee5\u4e0d\u52309\u4e07\u5b8c\u6210\u5168\u5957\u914d\u7f6e\uff0c\u4e0e\u5927\u91d1\u5bf9\u6bd4\u4f18\u52bf\u660e\u663e\u3002<br><br>\n      <strong>\u2462 \u5929\u51c0\u65b0\u98ce350\u8986\u76d6\u5065\u5eb7\u8212\u9002\u9700\u6c42\uff1a<\/strong>\u53cc\u5411\u5168\u70ed\u4ea4\u6362\uff0c\u5168\u70ed\u6548\u7387\u6700\u9ad880%\uff0cPM2.5\u4e00\u6b21\u51c0\u5316\u226598%\uff0c\u7eb3\u7c73\u9ad8\u5206\u5b50\u82af\u4f53\u53ef\u6c34\u6d17\u5bff\u547d\u226510\u5e74\uff0c\u4e0d\u5f00\u7a97\u4e5f\u80fd\u6052\u6c27\u6052\u51c0\uff0c\u5b8c\u7f8e\u8986\u76d6\u6c88\u5c0f\u59d0\u5bf9\u5065\u5eb7\u8212\u9002\u7684\u9690\u6027\u9700\u6c42\u3002<br><br>\n      <strong>\u2463 \u8d85\u4f4e\u6e29\u9664\u6e7f + 133\u33a1\u5730\u6696\uff1a<\/strong>\u6210\u90fd\/\u9e93\u6e56\u533a\u57df\u6625\u5b63\u56de\u5357\u5929\u3001\u6885\u96e8\u5b63\u6e7f\u5ea6\u9ad8\uff0c\u65b0\u667a\u4eab\u8d85\u4f4e\u6e29\u9664\u6e7f\u53ef\u5728\u4e0d\u964d\u5ba4\u6e29\u60c5\u51b5\u4e0b\u62bd\u6e7f\u3002\u51ac\u5b63133\u33a1\u5168\u5c4b\u5730\u6696\uff0c\u811a\u4e0b\u6e29\u6696\u8212\u9002\u3002<br><br>\n      <strong>\u2464 \u5b89\u88c5\u7b80\u6d01\uff0c\u7cfb\u7edf\u4e00\u4f53\u5316\uff1a<\/strong>\u65b0\u667a\u4eab\u6c34\u6a21\u5757\u5185\u7f6e\uff0c\u5b89\u88c5\u7b80\u5355\uff0c\u8bbe\u5907\u95f4\u9700\u6c42\u5c11\uff0c\u9002\u5408\u5927\u5e73\u5c42\u6237\u578b\u3002\n    <\/div>\n  <\/div>\n  <div class=\"verdict vb\">\n    <div class=\"verdict-ttl b\">\ud83d\udc51 \u65b9\u6848 B \u00b7 \u65e5\u7acb\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf \u2014\u2014 \u6781\u81f4\u8212\u9002\u65d7\u8230\u4e4b\u9009 <span class=\"five-const\">\u4e94\u6052\u207a<\/span><\/div>\n    <div class=\"verdict-body\">\n      <strong>\u2460 \u65e5\u7acb\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf\uff0c\u884c\u4e1a\u6807\u6746\uff1a<\/strong>\u5c0a\u777f\u5168\u6548\u4e3b\u673a + \u5929\u51c0\u65b0\u98ce + \u96c6\u63a7\u5c4f\uff0c\u5b9e\u73b0<strong>\u6052\u6e29\u00b7\u6052\u6e7f\u00b7\u6052\u6c27\u00b7\u6052\u6d01\u00b7\u6052\u9759<\/strong>\u4e94\u5927\u7ef4\u5ea6\u7684\u5168\u5c4b\u8054\u52a8\u667a\u63a7\u3002\u4e00\u5957\u7cfb\u7edf\u89e3\u51b3\u51b7\u6696\u3001\u6e7f\u5ea6\u3001\u65b0\u9c9c\u7a7a\u6c14\u3001\u6d01\u51c0\u5ea6\u3001\u9759\u97f3\u4e94\u5927\u5c45\u4f4f\u6307\u6807\uff0c\u8fd9\u662f\u65e5\u7acb\u5728\u4e2d\u592e\u7a7a\u8c03\u9886\u57df\u7684\u6700\u9ad8\u4ea7\u54c1\u5f62\u6001\u3002<br><br>\n      <strong>\u2461 \u884c\u4e1a\u552f\u4e00\u4e09\u7ba1\u5236\uff0c\u9664\u6e7f\u4f53\u9a8c\u65e0\u51fa\u5176\u53f3\uff1a<\/strong>\u4e09\u7ba1\u5236\u72ec\u7acb\u9664\u6e7f\u7ba1\u8def\u8ba9\u5236\u51b7\u3001\u5236\u70ed\u3001\u9664\u6e7f\u4e09\u8def\u5b8c\u5168\u5206\u5f00\uff0c\u590f\u5929\u9664\u6e7f\u65f6\u5ba4\u5185\u6e29\u5ea6\u7eb9\u4e1d\u4e0d\u52a8\u3002\u96c6\u63a7\u5c4f\u5b9e\u65f6\u76d1\u6d4b\u5404\u623f\u95f4\u6e29\u6e7f\u5ea6\uff0c\u81ea\u52a8\u8c03\u8282\u4e94\u6052\u53c2\u6570\uff0c\u5bf93~5\u4eba\u5e38\u4f4f\u4e14\u6709\u8001\u4eba\u6216\u5b69\u5b50\u7684\u5bb6\u5ead\uff0c\u4f53\u611f\u8212\u9002\u5ea6\u663e\u8457\u9ad8\u4e8e\u4efb\u4f55\u4e24\u7ba1\u5236\u65b9\u6848\u3002<br><br>\n      <strong>\u2462 PE\u207a\u5168\u98ce\u8def\u51c0\u5316\u8231 + \u5929\u51c0\u65b0\u98ce\u534f\u540c\uff1a<\/strong>\u6bcf\u53f0\u5185\u673a\u5747\u5e26\u5168\u98ce\u8def\u51c0\u5316\u8231\uff0c\u914d\u5408\u5929\u51c0\u65b0\u98ce350\u53cc\u5411\u5168\u70ed\u4ea4\u6362\uff0c\u5ba4\u5185\u5916\u7a7a\u6c14\u53cc\u91cd\u51c0\u5316\u3002\u4e94\u6052\u8054\u52a8\u6a21\u5f0f\u4e0b\uff0c\u65b0\u98ce\u4e0e\u7a7a\u8c03\u5730\u6696\u534f\u540c\u8fd0\u884c\uff0c\u5168\u5c4b\u7a7a\u6c14\u54c1\u8d28\u8fbe\u5230\u65d7\u8230\u7ea7\u6807\u51c6\u3002<br><br>\n      <strong>\u2463 APF\u6700\u9ad8\u53ef\u8fbe6.2\uff0c\u957f\u671f\u4f7f\u7528\u66f4\u7701\u7535\uff1a<\/strong>\u76f8\u6bd4\u65b9\u6848A\uff0c\u6bcf\u5e74\u8282\u7701\u7ea610~15%\u7535\u8d39\u3002\u4e94\u6052\u96c6\u63a7\u5c4f\u667a\u80fd\u8c03\u5ea6\u8bbe\u5907\u8fd0\u884c\u7b56\u7565\uff0c\u907f\u514d\u8fc7\u5ea6\u5236\u51b7\/\u5236\u70ed\uff0c\u957f\u671f\u8282\u7701\u66f4\u53ef\u89c2\u3002<br><br>\n      <strong>\u2464 133\u33a1\u5730\u6696\u5168\u5c4b\u8986\u76d6\uff1a<\/strong>\u4e0e\u65b9\u6848A\u76f8\u540c\u7684\u5730\u6696\u914d\u7f6e\uff0c\u4f46\u4e94\u6052\u8054\u52a8\u6a21\u5f0f\u4e0b\u51ac\u5b63\u53ef\u5b9e\u73b0\u6052\u6e29+\u6052\u6e7f\u8054\u52a8\u63a7\u5236\uff0c\u5730\u6696\u623f\u6e7f\u5ea6\u7ef4\u6301\u572840%~60%\u8212\u9002\u533a\u95f4\u3002\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- 08 \u7efc\u5408\u7ed3\u8bba -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">08<\/div>\n    <div><div class=\"sec-ttl\">\u7efc\u5408\u7ed3\u8bba\u4e0e\u63a8\u8350<\/div><div class=\"sec-desc\">\u57fa\u4e8e\u6c88\u5c0f\u59d0\u9700\u6c42\u7684\u6700\u7ec8\u5efa\u8bae<\/div><\/div>\n  <\/div>\n\n  <div class=\"rec-box\">\n    <div class=\"rec-inner\">\n      <div class=\"rec-star\">\u2b50<\/div>\n      <div class=\"rec-tag\">\u9996\u63a8\u65b9\u6848<\/div>\n      <div class=\"rec-plan\">\u65b9\u6848 A \u00b7 \u65e5\u7acb\u65b0\u667a\u4eab\uff08\u5929\u6c1f\u5730\u6c34+\u65b0\u98ce\uff09<\/div>\n      <div class=\"rec-reason\">\n        \u7efc\u5408\u6c88\u5c0f\u59d0\u300c\u5236\u51b7\u8981\u5feb\u300d\u7684\u6838\u5fc3\u8bc9\u6c42\u3001\u300c\u6709\u6027\u4ef7\u6bd4\u8981\u6c42\uff0c\u5728\u548c\u5927\u91d1\u5bf9\u6bd4\u300d\u7684\u53c2\u7167\u7cfb\uff0c\u65b9\u6848A\u4ee5<strong style=\"color:var(--gold-light);\">89,691\u5143<\/strong>\u5b8c\u6210\u7a7a\u8c03+\u5730\u6696+\u65b0\u98ce\u4e09\u5927\u7cfb\u7edf\u5168\u5957\u914d\u7f6e\uff0c\u5236\u51b7\u54cd\u5e94\u5feb\u3001\u5929\u51c0\u65b0\u98ce350\u8986\u76d6\u6052\u6c27\u6052\u51c0\u9700\u6c42\uff0c\u5bf9\u6bd4\u5927\u91d1\u540c\u7ea7\u65b9\u6848\u6709\u660e\u663e\u4ef7\u683c\u4f18\u52bf\uff0c\u8282\u7701\u7684\u7ea6<strong style=\"color:var(--gold-light);\">8,570\u5143<\/strong>\u53ef\u7528\u4e8e\u5347\u7ea7\u5730\u6696\u8f85\u6750\u54c1\u8d28\u6216\u6dfb\u7f6e\u5176\u4ed6\u5bb6\u5c45\u54c1\u8d28\u914d\u7f6e\u3002\n        <br><br>\n        <strong style=\"color:var(--gold-light);\">\u82e5\u6c88\u5c0f\u59d0\u5bf9\u300c\u5b8c\u5168\u4e0d\u964d\u6e29\u9664\u6e7f\u300d\u300c\u4e94\u6052\u667a\u63a7\u8054\u52a8\u300d\u300c\u5168\u5c4b\u5168\u611f\u7cfb\u7edf\u300d\u6709\u660e\u786e\u671f\u5f85\uff0c\u53ef\u5347\u7ea7\u65b9\u6848B\uff0898,261\u5143\uff09\uff0c\u83b7\u5f97\u65e5\u7acb\u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf\u65d7\u8230\u4f53\u9a8c\u3002<\/strong>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <table>\n    <thead class=\"hd-dark\">\n      <tr><th>\u51b3\u7b56\u56e0\u7d20<\/th><th>\u65b9\u6848A\u66f4\u4f18<\/th><th>\u65b9\u6848B\u66f4\u4f18<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr><td class=\"tl\">\u9884\u7b97\u63a7\u5236<\/td><td>\u2705 8.97\u4e07\uff0c\u8282\u7701\u7ea68,570\u5143<\/td><td>\u274c \u9700\u591a\u6295\u51658,570\u5143<\/td><\/tr>\n      <tr><td class=\"tl\">\u5236\u51b7\u901f\u5ea6<\/td><td>\u2705 \u6c1f\u5229\u6602\u76f4\u51b7\uff0c\u54cd\u5e94\u6700\u5feb<\/td><td>\u26aa \u7565\u900a<\/td><\/tr>\n      <tr><td class=\"tl\">\u5bf9\u6bd4\u5927\u91d1\u4f18\u52bf<\/td><td>\u2705 \u6027\u4ef7\u6bd4\u7a81\u51fa<\/td><td>\u26aa \u63a5\u8fd1\u5927\u91d1\u65d7\u8230\u4ef7\u4f4d<\/td><\/tr>\n      <tr><td class=\"tl\">\u9664\u6e7f\u8212\u9002\u5ea6<\/td><td>\u26aa \u8d85\u4f4e\u6e29\u9664\u6e7f\uff0c\u591f\u7528<\/td><td>\u2705 \u4e09\u7ba1\u5236\uff0c\u5b8c\u5168\u4e0d\u964d\u6e29<\/td><\/tr>\n      <tr><td class=\"tl\">\u65b0\u98ce\u6052\u6c27<\/td><td>\u2705 \u5929\u51c0\u65b0\u98ce350\uff0c\u4e24\u65b9\u6848\u76f8\u540c<\/td><td>\u2705 \u5929\u51c0\u65b0\u98ce350 + \u4e94\u6052\u8054\u52a8<\/td><\/tr>\n      <tr><td class=\"tl\">\u7a7a\u6c14\u5065\u5eb7\u51c0\u5316<\/td><td>\u26aa \u6807\u51c6PE\u51c0\u5316<\/td><td>\u2705 PE\u207a\u5168\u98ce\u8def\u51c0\u5316\u8231<\/td><\/tr>\n      <tr><td class=\"tl\">\u80fd\u6548\u8282\u7535<\/td><td>\u26aa APF 4.80~5.30<\/td><td>\u2705 APF 5.20~6.20 + \u4e94\u6052\u667a\u63a7<\/td><\/tr>\n      <tr><td class=\"tl\">\u7cfb\u7edf\u62d3\u5c55\u6027<\/td><td>\u26aa \u57fa\u7840\u529f\u80fd<\/td><td>\u2705 \u5168\u5c4b\u5168\u611f\u4e94\u6052\u7cfb\u7edf<\/td><\/tr>\n      <tr><td class=\"tl\">\u5730\u6696<\/td><td>\u2705 133\u33a1 \u5168\u5c4b\u5730\u6696\uff0c\u4e24\u65b9\u6848\u76f8\u540c<\/td><td>\u2705 133\u33a1 \u5730\u6696 + \u4e94\u6052\u6052\u6e29\u8054\u52a8<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n\n<!-- 09 \u670d\u52a1\u627f\u8bfa -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">09<\/div>\n    <div><div class=\"sec-ttl\">\u670d\u52a1\u627f\u8bfa<\/div><div class=\"sec-desc\">\u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5b98\u65b9\u6388\u6743 \u00b7 22\u5e74\u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u7cfb\u7edf<\/div><\/div>\n  <\/div>\n  <div class=\"cards\">\n    <div class=\"card\">\n      <div style=\"font-size:22px;margin-bottom:8px;\">\ud83d\udee1\ufe0f<\/div>\n      <div style=\"font-weight:800;margin-bottom:6px;\">\u5b98\u65b9\u6388\u6743\u8d28\u4fdd<\/div>\n      <div style=\"font-size:13px;color:var(--sub);\">\u4e3b\u673a\u6574\u673a\u8d28\u4fdd3\u5e74\uff0c\u5c0a\u777f\u7cfb\u5217\u538b\u7f29\u673a\u8d28\u4fdd6\u5e74\uff0c\u5b89\u88c5\u5de5\u827a\u8d28\u4fdd2\u5e74\u3002\u65b9\u6848B\u6c34\u6a21\u5757\u3001\u5929\u51c0\u65b0\u98ce\u540c\u4eab\u5b98\u65b9\u8d28\u4fdd\u4f53\u7cfb\u3002<\/div>\n    <\/div>\n    <div class=\"card\">\n      <div style=\"font-size:22px;margin-bottom:8px;\">\ud83d\udd27<\/div>\n      <div style=\"font-weight:800;margin-bottom:6px;\">\u4e13\u4e1a\u65bd\u5de5\u56e2\u961f<\/div>\n      <div style=\"font-size:13px;color:var(--sub);\">\u6301\u8bc1\u5b89\u88c5\u5de5\u7a0b\u5e08\uff0c\u4e25\u683c\u6267\u884c\u65e5\u7acb\u6807\u51c6\u65bd\u5de5\u89c4\u8303\u3002\u7a7a\u8c03\u7ba1\u8def\u3001\u5730\u6696\u94fa\u8bbe\u3001\u65b0\u98ce\u7ba1\u9053\u4e09\u4f4d\u4e00\u4f53\u540c\u6b65\u89c4\u5212\uff0c\u4fdd\u969c\u7cfb\u7edf\u957f\u671f\u7a33\u5b9a\u8fd0\u884c\u3002<\/div>\n    <\/div>\n    <div class=\"card\">\n      <div style=\"font-size:22px;margin-bottom:8px;\">\ud83d\udcf1<\/div>\n      <div style=\"font-weight:800;margin-bottom:6px;\">\u552e\u540e\u53ca\u65f6\u54cd\u5e94<\/div>\n      <div style=\"font-size:13px;color:var(--sub);\">\u6210\u90fd\u672c\u5730\u56e2\u961f\uff0c24\u5c0f\u65f6\u5185\u4e0a\u95e8\u670d\u52a1\uff0cApp\u8fdc\u7a0b\u534f\u52a9\u6392\u67e5\uff0c\u6bcf\u5e74\u4fdd\u517b\u5230\u671f\u4e3b\u52a8\u63d0\u9192\u3002\u65b9\u6848B\u4e94\u6052\u7cfb\u7edf\u4eab\u53d7\u4e13\u9879\u6280\u672f\u652f\u6301\u3002<\/div>\n    <\/div>\n    <div class=\"card\">\n      <div style=\"font-size:22px;margin-bottom:8px;\">\ud83d\udcd0<\/div>\n      <div style=\"font-weight:800;margin-bottom:6px;\">1\u5bf91\u65b9\u6848\u8bbe\u8ba1<\/div>\n      <div style=\"font-size:13px;color:var(--sub);\">\u63d0\u4f9b\u6237\u578b\u56fe\u540e\u51fa\u5177\u7cbe\u51c6\u914d\u7f6e\u65b9\u6848\uff0c\u542b\u7a7a\u8c03\u7ba1\u8def\u8d70\u5411\u3001\u5730\u6696\u5206\u6c34\u5668\u4f4d\u7f6e\u3001\u65b0\u98ce\u7ba1\u9053\u89c4\u5212\u3001\u5185\u673a\u70b9\u4f4d\u5e03\u7f6e\uff0c\u5168\u7a0b\u966a\u4f34\u670d\u52a1\u3002<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- 10 \u5929\u51c0\u65b0\u98ce350\u4ea7\u54c1\u8be6\u60c5 -->\n<div class=\"sec\">\n  <div class=\"sec-hd\">\n    <div class=\"sec-num\">10<\/div>\n    <div><div class=\"sec-ttl\">\u5929\u51c0\u65b0\u98ce350 \u4ea7\u54c1\u6982\u89c8<\/div><div class=\"sec-desc\">\u65e5\u7acb\u5168\u70ed\u4ea4\u6362\u65b0\u98ce \u00b7 \u4e24\u65b9\u6848\u5171\u7528<\/div><\/div>\n  <\/div>\n  <div class=\"specs\">\n    <div class=\"spec\"><div class=\"spec-val\">350m\u00b3\/h<\/div><div class=\"spec-lbl\">\u989d\u5b9a\u98ce\u91cf<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">80%<\/div><div class=\"spec-lbl\">\u5168\u70ed\u4ea4\u6362\u6548\u7387<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">\u226598%<\/div><div class=\"spec-lbl\">PM2.5\u4e00\u6b21\u51c0\u5316<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">21.5dB<\/div><div class=\"spec-lbl\">\u6700\u4f4e\u8fd0\u884c\u566a\u97f3<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">\u226510\u5e74<\/div><div class=\"spec-lbl\">\u82af\u4f53\u4f7f\u7528\u5bff\u547d<\/div><\/div>\n    <div class=\"spec\"><div class=\"spec-val\">15,700\u5143<\/div><div class=\"spec-lbl\">\u8bbe\u5907+\u5b89\u88c5\u603b\u4ef7<\/div><\/div>\n  <\/div>\n  <table>\n    <thead class=\"hd-dark\">\n      <tr><th>\u6838\u5fc3\u53c2\u6570<\/th><th>\u89c4\u683c\u8bf4\u660e<\/th><\/tr>\n    <\/thead>\n    <tbody>\n      <tr><td class=\"tl\">\u4ea7\u54c1\u578b\u53f7<\/td><td>KPI-3521Q5\/F\uff08\u5929\u51c0Q5-350\u667a\u80fd\u5168\u70ed\u4ea4\u6362\u578b\uff09<\/td><\/tr>\n      <tr><td class=\"tl\">\u989d\u5b9a\u98ce\u91cf<\/td><td>350m\u00b3\/h\uff0c\u9002\u7528120~180\u33a1\u5e73\u5c42<\/td><\/tr>\n      <tr><td class=\"tl\">\u5168\u70ed\u4ea4\u6362<\/td><td>\u7eb3\u7c73\u9ad8\u5206\u5b50\u82af\u4f53\uff0c\u7113\u4ea4\u6362\u6548\u7387\u6700\u9ad880%\uff0c\u6e29\u6e7f\u5ea6\u540c\u6b65\u56de\u6536<\/td><\/tr>\n      <tr><td class=\"tl\">\u51c0\u5316\u80fd\u529b<\/td><td>PM2.5\u4e00\u6b21\u51c0\u5316\u6548\u7387\u226598%\uff0cHEPA\u7cbe\u6ee4\uff0c\u521d\u6548\u53ef\u6c34\u6d17<\/td><\/tr>\n      <tr><td class=\"tl\">\u8fd0\u884c\u566a\u97f3<\/td><td>\u6700\u4f4e21.5dB(A)\uff0c\u5367\u5ba4\u9644\u8fd1\u5b89\u88c5\u4ea6\u4e0d\u53d7\u5f71\u54cd<\/td><\/tr>\n      <tr><td class=\"tl\">\u667a\u80fd\u63a7\u5236<\/td><td>\u6807\u914d\u7a7a\u6c14\u53ef\u89c6\u5316\u7ebf\u63a7\u5927\u5c4f + WiFi + \u65e5\u7acb\u667a\u5bb6APP<\/td><\/tr>\n      <tr><td class=\"tl\">\u82af\u4f53\u7ef4\u62a4<\/td><td>\u7eb3\u7c73\u9ad8\u5206\u5b50\u82af\u4f53\u53ef\u6c34\u6d17\u3001\u9632\u9709\u6297\u83cc\uff0c\u5bff\u547d\u226510\u5e74<\/td><\/tr>\n      <tr><td class=\"tl\">\u4e94\u6052\u8054\u52a8<\/td><td>\u65b9\u6848B\u4e2d\u53ef\u4e0e\u65e5\u7acb\u5168\u5c4b\u5168\u611f\u7cfb\u7edf\u8054\u52a8\uff0c\u5b9e\u73b0\u6052\u6e29\u6052\u6e7f\u6052\u6c27\u6052\u6d01\u6052\u9759<\/td><\/tr>\n      <tr><td class=\"tl\">\u4ef7\u683c<\/td><td>\u8bbe\u59079,500\u5143 + \u5b89\u88c56,200\u5143 = 15,700\u5143\uff08\u4ef7\u683c\u6307\u4ee4\u76f4\u62a5\uff09<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n  <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" class=\"src-link la\" target=\"_blank\" style=\"margin-top:10px;\">\ud83d\udd17 \u9f99\u8109\u6696\u901a \u00b7 \u65e5\u7acb\u5929\u51c0\u65b0\u98ce\u4ea7\u54c1\u8be6\u60c5\u9875<\/a>\n<\/div>\n\n<\/div><!-- end page -->\n\n<!-- FOOTER -->\n<div class=\"footer\">\n  <p><strong>\u9f99\u8109\u6696\u901a<\/strong> \u00b7 \u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8 \u00b7 \u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u5b98\u65b9\u6388\u6743\u670d\u52a1\u5546<\/p>\n  <p style=\"margin-top:6px;\">\u672c\u62a5\u4ef7\u4f9d\u636e\u9f99\u8109\u5b98\u7f51\u4ef7\u683c\u6307\u4ee4 V5.0\uff082026.05.23\uff09\u9762\u4ef7 \u00d7 8.5\u6298\u8ba1\u7b97\uff1b\u5730\u6696133\u33a1 \u00d7 179\u5143\/\u33a1\u7efc\u5408\u62a5\u4ef7\uff1b\u5929\u51c0\u65b0\u98ce350\u4ef7\u683c\u6307\u4ee4\u76f4\u62a5\uff1b\u5b89\u88c5\u8d39\u6309\u4e1a\u4e3b\u786e\u8ba4\u89c4\u5219<\/p>\n  <p style=\"margin-top:6px;\">\u4ea7\u54c1\u5916\u94fe\uff1a<a href=\"https:\/\/longmai-nt.com\/guide\/zhixiang.html\" style=\"color:var(--plan-a);\">\u65b0\u667a\u4eab\u8be6\u60c5<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/guide\/zunrui-shuimokuai.html\" style=\"color:var(--plan-b);\">\u5c0a\u777f\u6c34\u6a21\u5757\u8be6\u60c5<\/a> \u00b7 <a href=\"https:\/\/longmai-nt.com\/?page_id=1758\" style=\"color:var(--plan-a);\">\u5929\u51c0\u65b0\u98ce\u8be6\u60c5<\/a> \u00b7 \u4ef7\u683c\u6765\u6e90\uff1a<a href=\"https:\/\/longmai-nt.com\/?page_id=662\" style=\"color:var(--sub);\">\u6307\u4ee402\u4ea7\u54c1\u4ef7\u683c\u5e93<\/a><\/p>\n  <p style=\"margin-top:6px;\">\u5236\u4f5c\u65e5\u671f\uff1a2026\u5e746\u67087\u65e5 \u00b7 \u00a9 \u9f99\u8109\u6696\u901a \u00b7 \u7f2a\u8001\u5e08\u56e2\u961f<\/p>\n<\/div>\n\n<script>\n\/\/ ---- Radar Chart ----\n(function(){\n  const cv = document.getElementById('radar');\n  const ctx = cv.getContext('2d');\n  const W=520,H=400, cx=W\/2, cy=H\/2+10, R=140;\n  cv.width=W; cv.height=H;\n  const labels=['\u5236\u51b7\u901f\u5ea6','\u9664\u6e7f\u4f53\u9a8c','\u5065\u5eb7\u51c0\u5316','\u6027\u4ef7\u6bd4','\u80fd\u6548\u6c34\u5e73','\u4e94\u6052\u62d3\u5c55'];\n  const dA=[5,4,4,5,4,3];\n  const dB=[4,5,5,3,5,5];\n  const n=labels.length;\n  const pt=(i,v)=>{const a=(2*Math.PI*i\/n)-Math.PI\/2,r=(v\/5)*R;return{x:cx+r*Math.cos(a),y:cy+r*Math.sin(a)};};\n  \/\/ grid\n  for(let l=1;l<=5;l++){\n    ctx.beginPath();\n    for(let i=0;i<n;i++){const a=(2*Math.PI*i\/n)-Math.PI\/2,r=(l\/5)*R;const x=cx+r*Math.cos(a),y=cy+r*Math.sin(a);i===0?ctx.moveTo(x,y):ctx.lineTo(x,y);}\n    ctx.closePath();ctx.strokeStyle='rgba(0,0,0,0.08)';ctx.lineWidth=1;ctx.stroke();\n    if(l%2===0){ctx.fillStyle='rgba(0,0,0,0.02)';ctx.fill();}\n  }\n  \/\/ axes\n  for(let i=0;i<n;i++){const a=(2*Math.PI*i\/n)-Math.PI\/2;ctx.beginPath();ctx.moveTo(cx,cy);ctx.lineTo(cx+R*Math.cos(a),cy+R*Math.sin(a));ctx.strokeStyle='rgba(0,0,0,0.1)';ctx.lineWidth=1;ctx.stroke();}\n  \/\/ area A\n  ctx.beginPath();for(let i=0;i<n;i++){const p=pt(i,dA[i]);i===0?ctx.moveTo(p.x,p.y):ctx.lineTo(p.x,p.y);}\n  ctx.closePath();ctx.fillStyle='rgba(21,88,168,0.2)';ctx.fill();ctx.strokeStyle='#1558A8';ctx.lineWidth=2.5;ctx.stroke();\n  \/\/ area B\n  ctx.beginPath();for(let i=0;i<n;i++){const p=pt(i,dB[i]);i===0?ctx.moveTo(p.x,p.y):ctx.lineTo(p.x,p.y);}\n  ctx.closePath();ctx.fillStyle='rgba(123,30,79,0.2)';ctx.fill();ctx.strokeStyle='#7B1E4F';ctx.lineWidth=2.5;ctx.stroke();\n  \/\/ dots\n  [[dA,'#1558A8'],[dB,'#7B1E4F']].forEach(([d,c])=>{d.forEach((v,i)=>{const p=pt(i,v);ctx.beginPath();ctx.arc(p.x,p.y,5,0,2*Math.PI);ctx.fillStyle=c;ctx.fill();ctx.strokeStyle='#fff';ctx.lineWidth=2;ctx.stroke();});});\n  \/\/ labels\n  ctx.font='bold 13px PingFang SC,Microsoft YaHei,sans-serif';ctx.textAlign='center';ctx.textBaseline='middle';\n  for(let i=0;i<n;i++){const a=(2*Math.PI*i\/n)-Math.PI\/2,lx=cx+(R+30)*Math.cos(a),ly=cy+(R+30)*Math.sin(a);ctx.fillStyle='#1E1E1E';ctx.fillText(labels[i],lx,ly);}\n})();\n<\/script>\n<\/div><!-- end wrapper -->\n\n","protected":false},"excerpt":{"rendered":"<p>Proposal \u00b7 June 2026 [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2501","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2501\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"Proposal \u00b7 June 2026 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2501\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2501\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2501\",\"name\":\"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-07T08:45:25+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2501#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2501\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2501#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2501","og_locale":"zh_CN","og_type":"article","og_title":"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"Proposal \u00b7 June 2026 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2501","og_site_name":"\u9f99\u8109\u6696\u901a","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2501","url":"https:\/\/longmai-nt.com\/?page_id=2501","name":"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-07T08:45:25+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2501#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2501"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2501#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9e93\u6e56\u6c84\u5cb8\u6c88\u5c0f\u59d0\u6696\u901a\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2501","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2501"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2501\/revisions"}],"predecessor-version":[{"id":2502,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2501\/revisions\/2502"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2501"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}