{"id":2541,"date":"2026-06-07T18:47:05","date_gmt":"2026-06-07T10:47:05","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2541"},"modified":"2026-06-07T18:47:06","modified_gmt":"2026-06-07T10:47:06","slug":"%e9%98%b3%e5%a5%b3%e5%a3%ab%e4%b8%ad%e5%a4%ae%e7%a9%ba%e8%b0%83%e6%96%b9%e6%a1%88%e4%b9%a6","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2541","title":{"rendered":"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66"},"content":{"rendered":"\n\n<style>\n  * { margin: 0; padding: 0; box-sizing: border-box; }\n  body { font-family: -apple-system, \"PingFang SC\", \"Microsoft YaHei\", sans-serif; background: #f5f5f5; color: #333; line-height: 1.8; }\n\n  \/* \u5168\u5c40\u5bb9\u5668 \u2014\u2014 \u5bf9\u9f501024px\u5bbd\u5ea6 *\/\n  .container { max-width: 1024px; margin: 0 auto; padding: 0 20px; }\n  @media (max-width: 739px) { .container { padding: 0 12px; } }\n\n  \/* \u5c01\u9762 \u2014\u2014 \u80cc\u666f\u9650\u5236\u57281024px\u5185 *\/\n  .cover { padding: 24px 0; }\n  .cover-inner { max-width: 1024px; margin: 0 auto; padding: 60px 24px 40px; background: linear-gradient(135deg, #1a5276 0%, #2e86c1 100%); color: #fff; text-align: center; border-radius: 12px; }\n  @media (max-width: 739px) { .cover-inner { padding: 40px 16px 28px; } }\n  .cover .logo { font-size: 14px; opacity: 0.8; margin-bottom: 8px; letter-spacing: 2px; }\n  .cover h1 { font-size: 22px; font-weight: 700; margin: 16px 0 8px; line-height: 1.4; }\n  .cover .subtitle { font-size: 14px; opacity: 0.85; margin-bottom: 24px; }\n  .cover .meta { background: rgba(255,255,255,0.12); border-radius: 10px; padding: 16px 20px; margin: 0 auto; max-width: 400px; text-align: left; font-size: 13px; line-height: 2; }\n  .cover .meta span { color: #f0c040; }\n\n  \/* \u5bfc\u822a \u2014\u2014 \u5168\u5bbd\u4f46\u5185\u5bb9\u5c45\u4e2d *\/\n  .nav-wrap { background: #fff; border-bottom: 1px solid #eee; position: sticky; top: 0; z-index: 100; }\n  .nav { max-width: 1024px; margin: 0 auto; padding: 10px 20px; display: flex; gap: 6px; overflow-x: auto; -webkit-overflow-scrolling: touch; }\n  @media (max-width: 739px) { .nav { padding: 10px 12px; } }\n  .nav a { white-space: nowrap; font-size: 12px; color: #555; text-decoration: none; padding: 5px 12px; border-radius: 20px; background: #f0f4f8; flex-shrink: 0; }\n  .nav a.active { background: #1a5276; color: #fff; }\n\n  \/* \u5185\u5bb9\u533a *\/\n  .section { background: #fff; margin: 24px auto; border-radius: 12px; padding: 28px 32px; box-shadow: 0 1px 4px rgba(0,0,0,0.06); max-width: 1024px; }\n  @media (max-width: 739px) { .section { margin: 12px 8px; padding: 20px 16px; } }\n  .section-title { font-size: 17px; font-weight: 700; color: #1a5276; border-left: 4px solid #e67e22; padding-left: 10px; margin-bottom: 16px; }\n  .section-title2 { font-size: 15px; font-weight: 600; color: #2e86c1; margin: 18px 0 10px; }\n\n  \/* \u75db\u70b9\u8868\u683c *\/\n  .pain-table { width: 100%; border-collapse: collapse; font-size: 13px; }\n  .pain-table th { background: #1a5276; color: #fff; padding: 8px 10px; text-align: left; }\n  .pain-table td { padding: 9px 10px; border-bottom: 1px solid #eee; vertical-align: top; }\n  .pain-table tr:nth-child(even) td { background: #f8fafc; }\n  .pain-table .say { color: #888; }\n  .pain-table .real { color: #e67e22; font-weight: 600; }\n\n  \/* \u65b9\u6848\u5361\u7247 *\/\n  .plan-card { border: 2px solid #e8edf2; border-radius: 10px; padding: 14px; margin-bottom: 14px; position: relative; }\n  .plan-card.plan-a { border-color: #2e86c1; }\n  .plan-card.plan-b { border-color: #27ae60; }\n  .plan-tag { position: absolute; top: -1px; right: 16px; background: #2e86c1; color: #fff; font-size: 11px; padding: 3px 12px; border-radius: 0 0 8px 8px; }\n  .plan-card.plan-b .plan-tag { background: #27ae60; }\n  .plan-card h3 { font-size: 15px; color: #1a5276; margin-bottom: 10px; }\n  .plan-card.plan-b h3 { color: #27ae60; }\n\n  \/* \u8bbe\u5907\u8868 *\/\n  .dev-table { width: 100%; border-collapse: collapse; font-size: 12px; margin-top: 8px; }\n  .dev-table th { background: #f0f4f8; color: #444; padding: 7px 6px; text-align: left; font-weight: 600; }\n  .dev-table td { padding: 7px 6px; border-bottom: 1px solid #f0f0f0; }\n  .dev-table tr:last-child td { border-bottom: none; }\n\n  \/* \u5bf9\u6bd4\u8868 *\/\n  .cmp-table { width: 100%; border-collapse: collapse; font-size: 12.5px; }\n  .cmp-table th { background: #1a5276; color: #fff; padding: 8px 8px; text-align: left; }\n  .cmp-table td { padding: 8px 8px; border-bottom: 1px solid #eee; vertical-align: top; }\n  .cmp-table tr:nth-child(even) td { background: #f8fafc; }\n  .win { color: #27ae60; font-weight: 700; }\n  .lose { color: #aaa; }\n\n  \/* \u62a5\u4ef7\u8868 *\/\n  .price-table { width: 100%; border-collapse: collapse; font-size: 12px; }\n  .price-table th { background: #2e86c1; color: #fff; padding: 7px 6px; text-align: center; }\n  .price-table td { padding: 7px 6px; border-bottom: 1px solid #f0f0f0; text-align: center; }\n  .price-table .left { text-align: left; }\n  .price-table tr:last-child td { border-bottom: none; }\n  .price-table .total-row td { background: #fff8ee; font-weight: 700; color: #e67e22; font-size: 13px; }\n\n  \/* \u661f\u7ea7 *\/\n  .stars { color: #f0c040; font-size: 14px; }\n  .stars-low { color: #ccc; }\n\n  \/* \u9ad8\u4eae\u6846 *\/\n  .highlight { background: linear-gradient(135deg, #fff8ee, #fff3e0); border-left: 4px solid #e67e22; border-radius: 0 8px 8px 0; padding: 12px 14px; margin: 12px 0; font-size: 13px; line-height: 1.9; }\n  .highlight-blue { background: linear-gradient(135deg, #eaf2fb, #e8f4fd); border-color: #2e86c1; }\n\n  \/* \u603b\u4ef7\u5bf9\u6bd4 *\/\n  .total-compare { display: flex; gap: 12px; margin: 14px 0; flex-wrap: wrap; }\n  .total-box { flex: 1; min-width: 140px; border-radius: 10px; padding: 14px 12px; text-align: center; }\n  .total-box.a { background: #eaf2fb; border: 2px solid #2e86c1; }\n  .total-box.b { background: #eafaf1; border: 2px solid #27ae60; }\n  .total-box .label { font-size: 12px; color: #666; margin-bottom: 4px; }\n  .total-box .amount { font-size: 20px; font-weight: 700; }\n  .total-box.a .amount { color: #2e86c1; }\n  .total-box.b .amount { color: #27ae60; }\n  .total-box .note { font-size: 11px; color: #999; margin-top: 4px; }\n\n  \/* \u5efa\u8bae\u5361\u7247 *\/\n  .suggest-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 10px; margin: 12px 0; }\n  .suggest-card { border-radius: 10px; padding: 14px 12px; font-size: 12.5px; line-height: 1.9; }\n  .suggest-card.a { background: #eaf2fb; border: 1px solid #b3d4f5; }\n  .suggest-card.b { background: #eafaf1; border: 1px solid #a8dfc4; }\n  .suggest-card h4 { font-size: 13px; margin-bottom: 6px; }\n  .suggest-card.a h4 { color: #2e86c1; }\n  .suggest-card.b h4 { color: #27ae60; }\n  .suggest-card .check { color: #27ae60; }\n  .suggest-card .cross { color: #e74c3c; }\n\n  \/* \u670d\u52a1\u627f\u8bfa *\/\n  .service-list { list-style: none; }\n  .service-list li { padding: 9px 0 9px 28px; border-bottom: 1px solid #f0f0f0; font-size: 13px; position: relative; }\n  .service-list li:before { content: \"\u2713\"; position: absolute; left: 0; color: #27ae60; font-weight: 700; font-size: 15px; }\n\n  \/* \u4f1a\u5458\u6743\u76ca *\/\n  .vip-card { background: linear-gradient(135deg, #fff8ee, #fffde7); border: 2px solid #f0c040; border-radius: 10px; padding: 14px; margin: 10px 0; }\n  .vip-card h4 { color: #e67e22; font-size: 14px; margin-bottom: 8px; }\n  .vip-item { font-size: 12.5px; padding: 4px 0; }\n  .vip-item .vip-tag { display: inline-block; background: #f0c040; color: #333; font-size: 11px; padding: 1px 8px; border-radius: 10px; margin-right: 6px; }\n\n  \/* \u8054\u7cfb\u680f \u2014\u2014 \u80cc\u666f\u9650\u5236\u57281024px\u5185 *\/\n  .contact-bar { padding: 24px 0; }\n  .contact-bar .container { max-width: 1024px; margin: 0 auto; padding: 24px 16px; background: #1a5276; color: #fff; text-align: center; border-radius: 12px; }\n  .contact-bar h3 { font-size: 16px; margin-bottom: 12px; }\n  .contact-bar .phone { font-size: 22px; font-weight: 700; color: #f0c040; margin: 8px 0; }\n  .contact-bar .addr { font-size: 12px; opacity: 0.8; margin-top: 8px; line-height: 1.7; }\n\n  \/* \u6c34\u7cfb\u7edf\u63d0\u793a *\/\n  .tip-box { background: #f8fafc; border-radius: 8px; padding: 12px 14px; margin: 10px 0; font-size: 12.5px; color: #555; line-height: 1.9; }\n  .tip-box .tip-title { font-weight: 700; color: #1a5276; margin-bottom: 4px; }\n\n  \/* \u54cd\u5e94\u5f0f *\/\n  @media (max-width: 739px) {\n    .cover h1 { font-size: 19px; }\n    .total-compare { flex-direction: column; }\n    .suggest-grid { grid-template-columns: 1fr; }\n    .dev-table, .price-table, .cmp-table, .pain-table { font-size: 11px; }\n  }\n\n  \/* \u6253\u5370 *\/\n  @media print {\n    .nav { display: none; }\n    .section { box-shadow: none; border: 1px solid #ddd; page-break-inside: avoid; }\n    body { background: #fff; }\n  }\n<\/style>\n\n<!-- \u5c01\u9762 -->\n<div class=\"cover\">\n  <div class=\"cover-inner\">\n    <div class=\"logo\">LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a<\/div>\n    <h1>\u9633\u5973\u58eb<br>\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66<\/h1>\n    <div class=\"subtitle\">\u59cb\u4e8e2004 \u00b7 22\u5e74\u4e13\u4e1a\u6696\u901a\u670d\u52a1 \u00b7 \u6210\u90fd2\u4e07+\u5bb6\u5ead\u4fe1\u8d56<\/div>\n    <div class=\"meta\">\n      <div>\ud83d\udc64 <span>\u5ba2\u6237<\/span>\uff1a\u9633\u5973\u58eb<\/div>\n      <div>\ud83c\udfe0 <span>\u6237\u578b<\/span>\uff1a\u5ba2\u9910\u538560\u33a1 + \u4e3b\u536725\u33a1 + \u6b21\u53679.6\u33a1 + \u4e66\u623f11.5\u33a1<\/div>\n      <div>\ud83d\udc68\u200d\ud83d\udcbc <span>\u9500\u552e\u987e\u95ee<\/span>\uff1a\u8303\u4e3d\u5982<\/div>\n      <div>\ud83c\udfe2 <span>\u8bbe\u8ba1\u5355\u4f4d<\/span>\uff1a\u9f99\u8109\u6696\u901a<\/div>\n      <div>\ud83d\udcc5 <span>\u65b9\u6848\u65e5\u671f<\/span>\uff1a2026\u5e746\u6708<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- \u5bfc\u822a -->\n<div class=\"nav-wrap\">\n  <div class=\"nav\">\n    <a href=\"#sec1\">\u9700\u6c42\u75db\u70b9<\/a>\n    <a href=\"#sec2\">\u65b9\u6848\u914d\u7f6e<\/a>\n    <a href=\"#sec3\">\u6838\u5fc3\u5bf9\u6bd4<\/a>\n    <a href=\"#sec4\">\u900f\u660e\u62a5\u4ef7<\/a>\n    <a href=\"#sec5\">\u603b\u4ef7\u5bf9\u6bd4<\/a>\n    <a href=\"#sec6\">\u9009\u8d2d\u5efa\u8bae<\/a>\n    <a href=\"#sec7\">\u670d\u52a1\u627f\u8bfa<\/a>\n  <\/div>\n<\/div>\n\n<!-- \u4e00\u3001\u9700\u6c42\u4e0e\u75db\u70b9 -->\n<div class=\"section\" id=\"sec1\">\n  <div class=\"section-title\">\u4e00\u3001\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/div>\n  <p style=\"font-size:13px;color:#666;margin-bottom:12px;\">\u6839\u636e\u6c9f\u901a\u8bb0\u5f55\uff0c\u6211\u4eec\u6df1\u5165\u7406\u89e3\u60a8\u7684\u6838\u5fc3\u5173\u6ce8\u70b9\uff0c\u5e76\u5728\u65b9\u6848\u4e2d\u9010\u4e00\u56de\u5e94\u3002<\/p>\n  <table class=\"pain-table\">\n    <tr><th style=\"width:42%\">\u60a8\u8bf4\u7684<\/th><th>\u60a8\u771f\u6b63\u5173\u5fc3\u7684<\/th><\/tr>\n    <tr><td class=\"say\">\"\u7a7a\u8c03\u6548\u679c\u597d\u4e0d\u597d\"<\/td><td class=\"real\">\u5236\u51b7\u5236\u70ed\u6548\u679c\u2014\u2014\u590f\u5929\u591f\u4e0d\u591f\u51b7\uff0c\u51ac\u5929\u591f\u4e0d\u591f\u6696<\/td><\/tr>\n    <tr><td class=\"say\">\"\u4f1a\u4e0d\u4f1a\u5f88\u8d39\u7535\"<\/td><td class=\"real\">\u957f\u671f\u80fd\u8017\u2014\u2014\u6bcf\u4e2a\u6708\u7535\u8d39\u8981\u82b1\u591a\u5c11\u94b1<\/td><\/tr>\n    <tr><td class=\"say\">\"\u7a7a\u6c14\u8d28\u91cf\u600e\u4e48\u4fdd\u8bc1\"<\/td><td class=\"real\">\u5065\u5eb7\u51c0\u5316\u2014\u2014\u6709\u6ca1\u6709\u65b0\u98ce\u548c\u51c0\u5316\u529f\u80fd<\/td><\/tr>\n    <tr><td class=\"say\">\"\u5b89\u88c5\u9760\u4e0d\u9760\u8c31\"<\/td><td class=\"real\">\u540e\u671f\u7ef4\u62a4\u2014\u2014\u574f\u4e86\u80fd\u4e0d\u80fd\u627e\u5230\u3001\u80fd\u4e0d\u80fd\u4fee<\/td><\/tr>\n    <tr><td class=\"say\">\"\u4e24\u4e2a\u65b9\u6848\u54ea\u4e2a\u5212\u7b97\"<\/td><td class=\"real\">\u6027\u4ef7\u6bd4\u2014\u2014\u521d\u6295\u8d44\u548c\u957f\u671f\u4f7f\u7528\u6210\u672c<\/td><\/tr>\n  <\/table>\n<\/div>\n\n<!-- \u4e8c\u3001\u4e24\u5957\u65b9\u6848\u914d\u7f6e -->\n<div class=\"section\" id=\"sec2\">\n  <div class=\"section-title\">\u4e8c\u3001\u4e24\u5957\u65b9\u6848\u914d\u7f6e\u603b\u89c8<\/div>\n\n  <!-- \u65b9\u6848\u4e00 -->\n  <div class=\"plan-card plan-a\">\n    <div class=\"plan-tag\">\u65b9\u6848\u4e00<\/div>\n    <h3>\ud83c\udf1f \u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03\uff08DC\u6807\u51c6\u578b\uff09<\/h3>\n    <p style=\"font-size:12.5px;color:#666;margin-bottom:10px;\">\u9ad8\u6027\u4ef7\u6bd4\u4e4b\u9009\uff0cAPF 5.50\u8d85\u9ad8\u80fd\u6548\uff0c\u6ee1\u8db3\u57fa\u7840\u51b7\u6696\u9700\u6c42<\/p>\n\n    <div class=\"section-title2\">\u5ba4\u5185\u673a\u914d\u7f6e<\/div>\n    <table class=\"dev-table\">\n      <tr><th>\u533a\u57df<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><\/tr>\n      <tr><td>\u4e00\u697c<\/td><td>\u5ba2\u5385<\/td><td>\u7ea635\u33a1<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>7.1kW<\/td><\/tr>\n      <tr><td>\u4e00\u697c<\/td><td>\u9910\u5385<\/td><td>\u7ea625\u33a1<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>5.0kW<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u4e3b\u5367<\/td><td>25\u33a1<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>5.0kW<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>9.6\u33a1<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2.2kW<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u4e66\u623f<\/td><td>11.5\u33a1<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2.2kW<\/td><\/tr>\n      <tr style=\"background:#eaf2fb\"><td colspan=\"4\" style=\"text-align:right;font-weight:700;color:#2e86c1;\">\u5185\u673a\u5408\u8ba1 5\u53f0 \u603b\u51b7\u91cf<\/td><td style=\"font-weight:700;color:#2e86c1;\">21.5kW<\/td><\/tr>\n    <\/table>\n\n    <div class=\"section-title2\">\u5ba4\u5916\u4e3b\u673a<\/div>\n    <table class=\"dev-table\">\n      <tr><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u6838\u5fc3\u53c2\u6570<\/th><\/tr>\n      <tr><td>\u5ba4\u5916\u673a<\/td><td>AS-180HRNBQ<\/td><td>\u5236\u51b718.0kW \u00b7 \u5236\u70ed20.0kW \u00b7 APF 5.50 \u00b7 \u5355\u98ce\u6247<\/td><\/tr>\n    <\/table>\n    <div class=\"tip-box\">\n      <div class=\"tip-title\">\u2699\ufe0f \u8d85\u914d\u7387\u8bf4\u660e<\/div>\n      21.5kW \u00f7 18.0kW = 119.4%\uff08\u9ec4\u91d1\u533a\u95f4\uff0c\u7cfb\u7edf\u8fd0\u884c\u9ad8\u6548\u7a33\u5b9a\uff09\n    <\/div>\n  <\/div>\n\n  <!-- \u65b9\u6848\u4e8c -->\n  <div class=\"plan-card plan-b\">\n    <div class=\"plan-tag\">\u65b9\u6848\u4e8c<\/div>\n    <h3>\ud83d\udc8e \u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e2d\u592e\u7a7a\u8c03\uff08\u4e09\u7ba1DC\u51c0\u5316\u578b\uff09<\/h3>\n    <p style=\"font-size:12.5px;color:#666;margin-bottom:10px;\">\u9ad8\u7aef\u8212\u9002\u4e4b\u9009\uff0c\u6e29\u6e7f\u53cc\u63a7+\u6807\u914d\u51c0\u5316\uff0c\u5065\u5eb7\u4e0e\u8212\u9002\u517c\u5f97<\/p>\n\n    <div class=\"section-title2\">\u5ba4\u5185\u673a\u914d\u7f6e<\/div>\n    <table class=\"dev-table\">\n      <tr><th>\u533a\u57df<\/th><th>\u623f\u95f4<\/th><th>\u9762\u79ef<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u51b7\u91cf<\/th><\/tr>\n      <tr><td>\u4e00\u697c<\/td><td>\u5ba2\u5385<\/td><td>\u7ea635\u33a1<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>7.1kW<\/td><\/tr>\n      <tr><td>\u4e00\u697c<\/td><td>\u9910\u5385<\/td><td>\u7ea625\u33a1<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5.0kW<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u4e3b\u5367<\/td><td>25\u33a1<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5.0kW<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u6b21\u5367<\/td><td>9.6\u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2kW<\/td><\/tr>\n      <tr><td>\u4e8c\u697c<\/td><td>\u4e66\u623f<\/td><td>11.5\u33a1<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2kW<\/td><\/tr>\n      <tr style=\"background:#eafaf1\"><td colspan=\"4\" style=\"text-align:right;font-weight:700;color:#27ae60;\">\u5185\u673a\u5408\u8ba1 5\u53f0 \u603b\u51b7\u91cf<\/td><td style=\"font-weight:700;color:#27ae60;\">21.5kW<\/td><\/tr>\n    <\/table>\n\n    <div class=\"section-title2\">\u5ba4\u5916\u4e3b\u673a<\/div>\n    <table class=\"dev-table\">\n      <tr><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u6838\u5fc3\u53c2\u6570<\/th><\/tr>\n      <tr><td>\u5ba4\u5916\u673a<\/td><td>AS-180FSXPNQ<\/td><td>\u5236\u51b718.0kW \u00b7 \u5236\u70ed20.0kW \u00b7 APF 5.0 \u00b7 \u8865\u6c14\u589e\u7113\u538b\u7f29\u673a<\/td><\/tr>\n    <\/table>\n    <div class=\"tip-box\" style=\"border-color:#a8dfc4;\">\n      <div class=\"tip-title\">\u2699\ufe0f \u8d85\u914d\u7387\u8bf4\u660e<\/div>\n      21.5kW \u00f7 18.0kW = 119.4%\uff08\u9ec4\u91d1\u533a\u95f4\uff0c\u7cfb\u7edf\u8fd0\u884c\u9ad8\u6548\u7a33\u5b9a\uff09\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- \u4e09\u3001\u6838\u5fc3\u53c2\u6570\u5bf9\u6bd4 -->\n<div class=\"section\" id=\"sec3\">\n  <div class=\"section-title\">\u4e09\u3001\u4e24\u5957\u65b9\u6848\u6838\u5fc3\u5bf9\u6bd4<\/div>\n  <p style=\"font-size:13px;color:#666;margin-bottom:12px;\">\u6211\u4eec\u4ece7\u4e2a\u7ef4\u5ea6\u8fdb\u884c\u5ba2\u89c2\u5bf9\u6bd4\uff0c\u5e2e\u52a9\u60a8\u505a\u51fa\u6700\u9002\u5408\u7684\u9009\u62e9\u3002<\/p>\n  <table class=\"cmp-table\">\n    <tr><th style=\"width:28%\">\u5bf9\u6bd4\u7ef4\u5ea6<\/th><th>\u65b9\u6848\u4e00\uff1a\u8212\u4eabDC\u6807\u51c6\u578b<\/th><th>\u65b9\u6848\u4e8c\uff1a\u5168\u6548\u4e09\u7ba1DC\u51c0\u5316\u578b<\/th><th style=\"width:12%\">\u4f18\u52bf\u65b9<\/th><\/tr>\n    <tr>\n      <td>\u7a7a\u8c03\u5185\u673a<\/td><td>\u8212\u4eabDC\u6807\u51c6\u578b\uff085\u53f0\uff09<\/td><td>\u5168\u6548\u4e09\u7ba1DC\u51c0\u5316\u578b\uff085\u53f0\uff09<\/td><td class=\"win\">\u65b9\u6848\u4e8c\u5065\u5eb7\u5b8c\u80dc<\/td>\n    <\/tr>\n    <tr>\n      <td>\u6e29\u6e7f\u63a7\u5236<\/td><td><span class=\"stars\">\u2b50\u2b50\u2b50<\/span> \u57fa\u7840\u51b7\u6696<\/td><td><span class=\"stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span> \u6e29\u6e7f\u53cc\u63a7<\/td><td class=\"win\">\u65b9\u6848\u4e8c\u5b8c\u80dc<\/td>\n    <\/tr>\n    <tr>\n      <td>\u5065\u5eb7\u51c0\u5316<\/td><td><span class=\"stars\">\u2b50\u2b50<\/span> \u53ef\u9009\u914dPE<\/td><td><span class=\"stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span> \u6807\u914dPE+\u51c0\u5316<\/td><td class=\"win\">\u65b9\u6848\u4e8c\u5b8c\u80dc<\/td>\n    <\/tr>\n    <tr>\n      <td>\u7a7a\u8c03APF\u80fd\u6548<\/td><td>5.50<\/td><td>5.0<\/td><td class=\"win\">\u65b9\u6848\u4e00\u7565\u9ad8<\/td>\n    <\/tr>\n    <tr>\n      <td>\u8212\u9002\u5ea6<\/td><td><span class=\"stars\">\u2b50\u2b50\u2b50<\/span><\/td><td><span class=\"stars\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/span> \u4e09\u7ba1\u5236\u7cbe\u51c6\u63a7\u6e29<\/td><td class=\"win\">\u65b9\u6848\u4e8c\u5b8c\u80dc<\/td>\n    <\/tr>\n    <tr>\n      <td>\u6269\u5c55\u80fd\u529b<\/td><td>\u57fa\u7840\u7a7a\u8c03\u529f\u80fd<\/td><td>\u53ef\u5347\u7ea7\u4e09\u8054\u4f9b\uff08\u7a7a\u8c03+\u5730\u6696+\u70ed\u6c34\uff09<\/td><td class=\"win\">\u65b9\u6848\u4e8c\u6269\u5c55\u6027\u5f3a<\/td>\n    <\/tr>\n    <tr>\n      <td>\u521d\u6295\u8d44<\/td><td>\u66f4\u4f4e<\/td><td>\u8f83\u9ad8<\/td><td class=\"win\">\u65b9\u6848\u4e00\u521d\u6295\u66f4\u4f4e<\/td>\n    <\/tr>\n  <\/table>\n<\/div>\n\n<!-- \u56db\u3001\u900f\u660e\u62a5\u4ef7 -->\n<div class=\"section\" id=\"sec4\">\n  <div class=\"section-title\">\u56db\u3001\u900f\u660e\u62a5\u4ef7\uff088\u6298\u6838\u7b97\uff09<\/div>\n\n  <div class=\"section-title2\" style=\"color:#2e86c1;\">\u65b9\u6848\u4e00\uff1a\u65e5\u7acb\u8212\u4eab\u4e2d\u592e\u7a7a\u8c03<\/div>\n  <table class=\"price-table\">\n    <tr><th class=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7<\/th><th>8\u6298\u540e<\/th><th>\u5b89\u88c5\u8d39\/\u53f0<\/th><th>\u5b89\u88c5\u8d39\u5408\u8ba1<\/th><\/tr>\n    <tr><td class=\"left\">\u8212\u4eab\u5185\u673a71<\/td><td>RPIZ-71FSNAQD\/P<\/td><td>1<\/td><td>3,513<\/td><td>2,810<\/td><td>1,600<\/td><td>1,600<\/td><\/tr>\n    <tr><td class=\"left\">\u8212\u4eab\u5185\u673a50<\/td><td>RPIZ-50FSNAQD\/P<\/td><td>2<\/td><td>3,250\u00d72<\/td><td>5,200<\/td><td>1,600\u00d72<\/td><td>3,200<\/td><\/tr>\n    <tr><td class=\"left\">\u8212\u4eab\u5185\u673a22<\/td><td>RPIZ-22FSNAQD\/P<\/td><td>2<\/td><td>3,013\u00d72<\/td><td>4,820<\/td><td>1,600\u00d72<\/td><td>3,200<\/td><\/tr>\n    <tr><td class=\"left\">\u8212\u4eab\u5916\u673a180<\/td><td>AS-180HRNBQ<\/td><td>1<\/td><td>16,150<\/td><td>12,920<\/td><td>600<\/td><td>600<\/td><\/tr>\n    <tr class=\"total-row\"><td class=\"left\" colspan=\"6\">\u8bbe\u5907+\u5b89\u88c5\u8d39\u5408\u8ba1<\/td><td>\u7ea634,350\u5143<\/td><\/tr>\n  <\/table>\n  <div class=\"tip-box\" style=\"margin-top:10px;\">\u6ce8\uff1a\u4ee5\u4e0a\u4e0d\u542b\u7ebf\u63a7\u5668\u30013D\u98ce\u53e3\u7b49\u914d\u4ef6\u3002<\/div>\n\n  <div class=\"section-title2\" style=\"color:#27ae60;margin-top:20px;\">\u65b9\u6848\u4e8c\uff1a\u65e5\u7acb\u5c0a\u777f\u5168\u6548\u4e09\u7ba1\u4e2d\u592e\u7a7a\u8c03<\/div>\n  <table class=\"price-table\">\n    <tr><th class=\"left\">\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th>\u9762\u4ef7<\/th><th>8\u6298\u540e<\/th><th>\u5b89\u88c5\u8d39\/\u53f0<\/th><th>\u5b89\u88c5\u8d39\u5408\u8ba1<\/th><\/tr>\n    <tr><td class=\"left\">\u5168\u6548\u4e09\u7ba1\u5185\u673a71<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>1<\/td><td>5,825<\/td><td>4,660<\/td><td>1,900<\/td><td>1,900<\/td><\/tr>\n    <tr><td class=\"left\">\u5168\u6548\u4e09\u7ba1\u5185\u673a50<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>2<\/td><td>5,663\u00d72<\/td><td>9,060<\/td><td>1,900\u00d72<\/td><td>3,800<\/td><\/tr>\n    <tr><td class=\"left\">\u5168\u6548\u4e09\u7ba1\u5185\u673a22<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2<\/td><td>5,050\u00d72<\/td><td>8,080<\/td><td>1,900\u00d72<\/td><td>3,800<\/td><\/tr>\n    <tr><td class=\"left\">\u5168\u6548\u5916\u673a180<\/td><td>AS-180FSXPNQ<\/td><td>1<\/td><td>34,788<\/td><td>27,830<\/td><td>600<\/td><td>600<\/td><\/tr>\n    <tr class=\"total-row\" style=\"background:#eafaf1\"><td class=\"left\" colspan=\"6\"><strong>\u65b9\u6848\u4e8c\u5408\u8ba1\uff08\u8bbe\u5907+\u5b89\u88c5\uff09<\/strong><\/td><td><strong>\u7ea659,770\u5143<\/strong><\/td><\/tr>\n  <\/table>\n<\/div>\n\n<!-- \u4e94\u3001\u603b\u4ef7\u5bf9\u6bd4 -->\n<div class=\"section\" id=\"sec5\">\n  <div class=\"section-title\">\u4e94\u3001\u4e24\u5957\u65b9\u6848\u603b\u4ef7\u5bf9\u6bd4<\/div>\n  <div class=\"total-compare\">\n    <div class=\"total-box a\">\n      <div class=\"label\">\u65b9\u6848\u4e00 \u00b7 \u8212\u4eabDC\u6807\u51c6\u578b<\/div>\n      <div class=\"amount\">\u00a534,550<\/div>\n      <div class=\"note\">\u9ad8\u6027\u4ef7\u6bd4\u4e4b\u9009<\/div>\n    <\/div>\n    <div class=\"total-box b\">\n      <div class=\"label\">\u65b9\u6848\u4e8c \u00b7 \u5168\u6548\u4e09\u7ba1DC\u51c0\u5316\u578b<\/div>\n      <div class=\"amount\">\u00a559,770<\/div>\n      <div class=\"note\">\u9ad8\u7aef\u8212\u9002\u4e4b\u9009<\/div>\n    <\/div>\n  <\/div>\n  <div class=\"highlight\">\n    \ud83d\udca1 <strong>\u521d\u6295\u8d44\u5dee\u989d\u5206\u6790\uff1a<\/strong><br>\n    \u65b9\u6848\u4e8c\u6bd4\u65b9\u6848\u4e00\u521d\u6295\u8d44\u9ad8 <strong style=\"color:#e67e22;font-size:16px;\">\u7ea625,220\u5143<\/strong><br>\n    <span style=\"font-size:12px;color:#888;\">\u65b9\u6848\u4e8c\u5e26\u6765\u7684\u662f\u6e29\u6e7f\u53cc\u63a7\u3001\u6807\u914d\u51c0\u5316\u3001\u53ef\u5347\u7ea7\u4e09\u8054\u4f9b\u7684\u9ad8\u7aef\u4f53\u9a8c<\/span>\n  <\/div>\n<\/div>\n\n<!-- \u516d\u3001\u9009\u8d2d\u5efa\u8bae -->\n<div class=\"section\" id=\"sec6\">\n  <div class=\"section-title\">\u516d\u3001\u9009\u8d2d\u5efa\u8bae<\/div>\n  <p style=\"font-size:13px;color:#666;margin-bottom:12px;\">\u6839\u636e\u60a8\u7684\u5bb6\u5ead\u60c5\u51b5\u548c\u5173\u6ce8\u91cd\u70b9\uff0c\u4e3a\u60a8\u68b3\u7406\u9009\u8d2d\u65b9\u5411\uff1a<\/p>\n\n  <div class=\"suggest-grid\">\n    <div class=\"suggest-card a\">\n      <h4>\u2705 \u9009\u65b9\u6848\u4e00\uff08\u8212\u4eabDC\u6807\u51c6\u578b\uff09\u5982\u679c\uff1a<\/h4>\n      <div class=\"check\">\u25b8 \u9884\u7b97\u76f8\u5bf9\u654f\u611f\uff0c\u5e0c\u671b\u521d\u6295\u8d44\u66f4\u53ef\u63a7<\/div>\n      <div class=\"check\">\u25b8 \u6ee1\u8db3\u57fa\u7840\u51b7\u6696\u9700\u6c42\u5373\u53ef<\/div>\n      <div class=\"check\">\u25b8 \u5bf9\u6e29\u6e7f\u53cc\u63a7\u65e0\u7279\u6b8a\u8981\u6c42<\/div>\n      <div class=\"check\">\u25b8 \u540e\u671f\u6709\u5347\u7ea7\u8ba1\u5212\uff08\u5148\u88c5\u7a7a\u8c03\uff0c\u5730\u6696\/\u70ed\u6c34\u540e\u7eed\u518d\u52a0\uff09<\/div>\n    <\/div>\n    <div class=\"suggest-card b\">\n      <h4>\u2705 \u9009\u65b9\u6848\u4e8c\uff08\u5168\u6548\u4e09\u7ba1DC\u51c0\u5316\u578b\uff09\u5982\u679c\uff1a<\/h4>\n      <div class=\"check\">\u25b8 \u8ffd\u6c42\u6781\u81f4\u8212\u9002\u548c\u5065\u5eb7\uff08\u6e29\u6e7f\u53cc\u63a7+\u51c0\u5316\uff09<\/div>\n      <div class=\"check\">\u25b8 \u5bf9\u7a7a\u6c14\u8d28\u91cf\u6709\u8f83\u9ad8\u8981\u6c42\uff08\u8fc7\u654f\u4eba\u7fa4\/\u6709\u8001\u4eba\u5c0f\u5b69\uff09<\/div>\n      <div class=\"check\">\u25b8 \u8ba1\u5212\u4e00\u6b65\u5230\u4f4d\uff0c\u957f\u671f\u81ea\u4f4f<\/div>\n      <div class=\"check\">\u25b8 \u5e0c\u671b\u7cfb\u7edf\u6709\u6269\u5c55\u5347\u7ea7\u7a7a\u95f4\uff08\u4e09\u8054\u4f9b\uff09<\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- \u4e03\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u4f1a\u5458\u6743\u76ca -->\n<div class=\"section\" id=\"sec7\">\n  <div class=\"section-title\">\u4e03\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u4f1a\u5458\u6743\u76ca<\/div>\n\n  <div class=\"section-title2\">\ud83d\udee1\ufe0f \u9f99\u8109\u6696\u901a\u670d\u52a1\u627f\u8bfa<\/div>\n  <ul class=\"service-list\">\n    <li><strong>\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/strong> \u2014 48\u5c0f\u65f6\u5185\u54cd\u5e94\uff0c\u4e13\u4e1a\u5de5\u7a0b\u5e08\u4e0a\u95e8<\/li>\n    <li><strong>\u591a\u79cd\u65b9\u6848\u5bf9\u6bd4<\/strong> \u2014 \u4e0d\u5c11\u4e8e2\u5957\u8bbe\u8ba1\u65b9\u6848\uff0c\u5ba2\u89c2\u5206\u6790\u4f18\u52a3<\/li>\n    <li><strong>\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/strong> \u2014 \u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6\uff0c\u7cbe\u5de5\u516d\u6b65\u6cd5<\/li>\n    <li><strong>\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/strong> \u2014 \u65e0\u9690\u85cf\u589e\u9879\uff0c\u6bcf\u4e00\u5206\u94b1\u82b1\u5f97\u660e\u767d<\/li>\n    <li><strong>5\u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/strong> \u2014 \u8fdc\u8d85\u884c\u4e1a\u6807\u51c6\uff0c\u8ba9\u60a8\u65e0\u540e\u987e\u4e4b\u5fe7<\/li>\n    <li><strong>\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/strong> \u2014 \u5e74\u5ea6\u68c0\u6d4b+\u7ef4\u4fdd\u63d0\u9192\uff0c\u957f\u671f\u8ddf\u8e2a<\/li>\n  <\/ul>\n\n  <div class=\"section-title2\" style=\"margin-top:18px;\">\ud83c\udf81 \u4f1a\u5458\u6743\u76ca\uff08\u6d3b\u52a8\u671f\u95f4\uff09<\/div>\n  <div class=\"vip-card\">\n    <h4>\u9f99\u8109\u6696\u901aVIP\u4f1a\u5458 \u00b7 199\u5143\/\u5e74<\/h4>\n    <div class=\"vip-item\"><span class=\"vip-tag\">\u6696\u901a\u91d1\u989d<\/span>\u7b7e\u7ea6\u90011,000\u5143\uff08\u53ef\u62b5\u6263\u4f1a\u5458\u8d39\/\u8bbe\u5907\u6b3e\/\u5b89\u88c5\u8d39\uff09<\/div>\n    <div class=\"vip-item\"><span class=\"vip-tag\">\u65e5\u7acb\u5382\u8865<\/span>\u8212\u4eab\u7cfb\u5217 \u2192 500\u5143\/\u6237 \u00b7 \u5c0a\u777f\u5168\u6548 \u2192 2,000\u5143\/\u6237<\/div>\n    <div class=\"vip-item\"><span class=\"vip-tag\">\u8bbe\u5907\u5ef6\u4fdd<\/span>\u5165\u4f1a\u5458\u540e\u8212\u4eab\/\u5168\u6548\u5ef6\u4fdd\u81f310\u5e74<\/div>\n    <div class=\"tip-box\" style=\"margin-top:10px;border-color:#f0c040;\">\ud83d\udca1 \u9996\u5e74\u4f1a\u5458\u8d39\u53ef\u7528\u6696\u901a\u91d1\u989d\u62b5\u6263\uff0c\u76f8\u5f53\u4e8e<strong>\u514d\u8d39\u5165\u4f1a<\/strong>\uff01<\/div>\n  <\/div>\n\n  <div class=\"highlight\" style=\"margin-top:16px;\">\n    \ud83d\udccc <strong>\u6211\u4eec\u7684\u7406\u5ff5\uff1a<\/strong><br>\n    \"\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002\"<br>\n    \u9f99\u8109\u6696\u901a\u4e3a\u6bcf\u4e00\u4f4d\u7b7e\u7ea6\u7528\u6237\u5efa\u7acb\u4e13\u5c5e\u9879\u76ee\u6863\u6848\uff0c\u8986\u76d6\u52d8\u6d4b\u3001\u8bbe\u8ba1\u3001\u65bd\u5de5\u3001\u4ea4\u4ed8\u5168\u6d41\u7a0b\uff0c\u4ea4\u4ed8\u540e\u6301\u7eed\u66f4\u65b0\u7ef4\u4fdd\u8bb0\u5f55\u548c\u80fd\u8017\u6570\u636e\uff0c\u8ba9\u60a8\u957f\u671f\u65e0\u5fe7\u3002\n  <\/div>\n<\/div>\n\n<!-- \u8054\u7cfb\u65b9\u5f0f -->\n<div class=\"contact-bar\">\n  <div class=\"container\">\n    <h3>\u9f99\u8109\u6696\u901a \u00b7 \u59cb\u4e8e2004<\/h3>\n    <p>2\u4e07+\u6210\u90fd\u5bb6\u5ead\u7684\u4fe1\u8d56\u4e4b\u9009<\/p>\n    <div class=\"phone\">\ud83d\udcde 133 9819 8375<\/div>\n    <p style=\"font-size:13px;margin:4px 0;\">\u9500\u552e\u987e\u95ee\uff1a\u8303\u4e3d\u5982\uff08\u5fae\u4fe1\u540c\u53f7\uff09<\/p>\n    <div class=\"addr\">\n      \ud83d\udccd \u5357\u5bcc\u68ee\u9ad8\u65b0\u5e97\uff08\u65e5\u7acb\u65d7\u8230\u5e97\uff09<br>\n      \u9ad8\u65b0\u533a\u90fd\u4f1a\u8def99\u53f7\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u99863\u697cA348<br><br>\n      \ud83d\udccd \u5317\u5bcc\u68ee\u6210\u534e\u5e97\uff08\u667a\u6167\u7a7a\u6c14\u9986\uff09<br>\n      \u6210\u534e\u533a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986A\u5e625\u697cA5135\u53f7\n    <\/div>\n    <div style=\"margin-top:16px;font-size:12px;opacity:0.7;\">\n      \u5b98\u7f51\uff1alongmai-nt.com &nbsp;|&nbsp; ICP\u5907\u6848\uff1a\u8700ICP\u59072026015986\u53f7\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- \u5e95\u90e8 -->\n<div class=\"container\" style=\"text-align:center;padding:20px;color:#aaa;font-size:12px;\">\n  \u672c\u65b9\u6848\u7531\u9f99\u8109\u6696\u901a\u9500\u552e\u987e\u95ee\u8303\u4e3d\u5982\u7f16\u5236 &nbsp;|&nbsp; 2026\u5e746\u6708 &nbsp;|&nbsp; \u4fdd\u7559\u6240\u6709\u6743\u5229\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a  [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2541","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2541\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2541\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-07T10:47:06+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2541\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2541\",\"name\":\"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-07T10:47:05+00:00\",\"dateModified\":\"2026-06-07T10:47:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2541#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2541\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2541#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2541","og_locale":"zh_CN","og_type":"article","og_title":"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","og_description":"LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2541","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-07T10:47:06+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"3 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2541","url":"https:\/\/longmai-nt.com\/?page_id=2541","name":"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-07T10:47:05+00:00","dateModified":"2026-06-07T10:47:06+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2541#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2541"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2541#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u9633\u5973\u58eb\u4e2d\u592e\u7a7a\u8c03\u65b9\u6848\u4e66"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2541"}],"version-history":[{"count":1,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2541\/revisions"}],"predecessor-version":[{"id":2542,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2541\/revisions\/2542"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}