{"id":2640,"date":"2026-06-10T14:56:43","date_gmt":"2026-06-10T06:56:43","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2640"},"modified":"2026-06-14T13:18:38","modified_gmt":"2026-06-14T05:18:38","slug":"%e5%b0%8f%e5%91%a8%e8%80%81%e5%b8%88-%c2%b7-%e9%be%99%e6%b9%96%e4%b8%89%e5%8d%83%e9%9b%86%e5%ae%8c%e6%95%b4%e7%89%88%e5%af%b9%e6%af%94%e6%8a%a5%e4%bb%b7%e6%96%b9%e6%a1%88","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2640","title":{"rendered":"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848"},"content":{"rendered":"\n\n<div class=\"lm-wrapper\">\n<style>\n\/* ============================================================\n   \u9f99\u8109\u6696\u901a \u00b7 \u4e09\u65b9\u6848\u5bf9\u6bd4\u62a5\u4ef7\u4e66 \u00b7 WordPress Self-Contained Fragment\n   \u5ba2\u6237\uff1a\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\n   \u751f\u6210\u65e5\u671f\uff1a2026-06-14\n   \u89c4\u8303\uff1alm- \u524d\u7f00\u9694\u79bb \u00b7 \u96f6\u5916\u90e8\u4f9d\u8d56 \u00b7 \u6253\u5370\u53cb\u597d\n   ============================================================ *\/\n\n\/* --- \u57fa\u7840\u5bb9\u5668 --- *\/\n.lm-wrapper {\n  max-width: 100%;\n  overflow-x: hidden;\n  box-sizing: border-box;\n  display: block;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", \"PingFang SC\", \"Hiragino Sans GB\", \"Microsoft YaHei\", \"Helvetica Neue\", Arial, sans-serif;\n  color: #333333;\n  line-height: 1.7;\n  background: #f5f7fa;\n}\n\n.lm-wrapper *, .lm-wrapper *::before, .lm-wrapper *::after {\n  box-sizing: border-box;\n}\n\n\/* ============================================================\n   \u5c01\u9762\u533a \u00b7 Hero Section\n   ============================================================ *\/\n.lm-wrapper .lm-hero {\n  background: linear-gradient(150deg, #0d2b5e 0%, #1a4a8a 45%, #0d6efd 100%);\n  color: #ffffff;\n  padding: 60px 40px 50px;\n  text-align: center;\n  position: relative;\n  overflow: hidden;\n}\n\n.lm-wrapper .lm-hero::before {\n  content: \"\";\n  position: absolute;\n  top: -60px;\n  right: -60px;\n  width: 300px;\n  height: 300px;\n  background: rgba(255,255,255,0.04);\n  border-radius: 50%;\n}\n\n.lm-wrapper .lm-hero::after {\n  content: \"\";\n  position: absolute;\n  bottom: -80px;\n  left: -40px;\n  width: 250px;\n  height: 250px;\n  background: rgba(255,255,255,0.03);\n  border-radius: 50%;\n}\n\n.lm-wrapper .lm-hero-brand {\n  font-size: 12px;\n  letter-spacing: 4px;\n  opacity: 0.7;\n  text-transform: uppercase;\n  margin-bottom: 10px;\n}\n\n.lm-wrapper .lm-hero h1 {\n  font-size: 34px;\n  font-weight: 800;\n  margin: 10px 0 6px;\n  letter-spacing: 2px;\n  line-height: 1.3;\n}\n\n.lm-wrapper .lm-hero .lm-hero-sub {\n  font-size: 16px;\n  opacity: 0.85;\n  margin-bottom: 28px;\n  letter-spacing: 1px;\n}\n\n.lm-wrapper .lm-hero-meta {\n  display: inline-flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  justify-content: center;\n  margin-bottom: 30px;\n}\n\n.lm-wrapper .lm-hero-meta-item {\n  background: rgba(255,255,255,0.12);\n  border: 1px solid rgba(255,255,255,0.25);\n  border-radius: 6px;\n  padding: 8px 16px;\n  font-size: 14px;\n}\n\n.lm-wrapper .lm-hero-meta-item strong {\n  font-weight: 600;\n  margin-right: 4px;\n}\n\n\/* \u951a\u70b9\u5bfc\u822a\u6309\u94ae\u7ec4 *\/\n.lm-wrapper .lm-anchor-nav {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 8px;\n  justify-content: center;\n  margin-top: 20px;\n}\n\n.lm-wrapper .lm-anchor-btn {\n  display: inline-block;\n  padding: 7px 16px;\n  border-radius: 20px;\n  background: rgba(255,255,255,0.15);\n  border: 1px solid rgba(255,255,255,0.35);\n  color: #ffffff;\n  font-size: 13px;\n  text-decoration: none;\n  cursor: pointer;\n}\n\n.lm-wrapper .lm-hero-tagline {\n  font-size: 12px;\n  opacity: 0.6;\n  margin-top: 22px;\n  letter-spacing: 1px;\n}\n\n.lm-wrapper .lm-hero-prices {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 16px;\n  justify-content: center;\n  margin-top: 24px;\n}\n\n.lm-wrapper .lm-hero-price-item {\n  background: rgba(255,255,255,0.1);\n  border: 1px solid rgba(255,255,255,0.2);\n  border-radius: 8px;\n  padding: 12px 20px;\n  text-align: center;\n  min-width: 140px;\n}\n\n.lm-wrapper .lm-hero-price-item .lm-hero-price-label {\n  font-size: 12px;\n  opacity: 0.7;\n  margin-bottom: 4px;\n}\n\n.lm-wrapper .lm-hero-price-item .lm-hero-price-val {\n  font-size: 20px;\n  font-weight: 700;\n  color: #fcd34d;\n}\n\n\/* ============================================================\n   \u7ae0\u8282\u5bb9\u5668\n   ============================================================ *\/\n.lm-wrapper .lm-section {\n  background: #ffffff;\n  margin: 16px 0;\n  padding: 36px 32px;\n  box-shadow: 0 2px 12px rgba(0,0,0,0.06);\n}\n\n.lm-wrapper .lm-section:first-of-type {\n  margin-top: 0;\n}\n\n.lm-wrapper .lm-section-title {\n  display: flex;\n  align-items: center;\n  gap: 12px;\n  margin: 0 0 24px;\n  padding-bottom: 14px;\n  border-bottom: 2px solid #eef2f8;\n}\n\n.lm-wrapper .lm-section-title h2 {\n  font-size: 22px;\n  font-weight: 700;\n  color: #0d2b5e;\n  margin: 0;\n}\n\n.lm-wrapper .lm-section-num {\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  width: 32px;\n  height: 32px;\n  border-radius: 50%;\n  background: linear-gradient(135deg, #0d2b5e, #1a4a8a);\n  color: #ffffff;\n  font-size: 14px;\n  font-weight: 700;\n  flex-shrink: 0;\n}\n\n.lm-wrapper .lm-section-desc {\n  color: #666666;\n  font-size: 14px;\n  margin: -12px 0 24px;\n}\n\n.lm-wrapper .lm-sub-title {\n  font-size: 16px;\n  font-weight: 700;\n  color: #0d2b5e;\n  margin: 24px 0 12px;\n  padding-left: 12px;\n  border-left: 3px solid #c8a44e;\n}\n\n\/* ============================================================\n   \u8868\u683c\n   ============================================================ *\/\n.lm-wrapper .lm-table-wrap {\n  overflow-x: auto;\n  -webkit-overflow-scrolling: touch;\n  margin: 16px 0;\n  border-radius: 8px;\n  box-shadow: 0 1px 6px rgba(0,0,0,0.07);\n}\n\n.lm-wrapper .lm-table {\n  width: 100%;\n  table-layout: auto;\n  border-collapse: collapse;\n  font-size: 14px;\n}\n\n.lm-wrapper .lm-table thead tr {\n  background: linear-gradient(90deg, #0d2b5e, #1a4a8a);\n  color: #ffffff;\n}\n\n.lm-wrapper .lm-table th {\n  padding: 13px 16px;\n  text-align: left;\n  font-weight: 600;\n  font-size: 13px;\n  letter-spacing: 0.5px;\n  white-space: nowrap;\n}\n\n.lm-wrapper .lm-table td {\n  padding: 11px 16px;\n  border-bottom: 1px solid #eef2f8;\n  color: #444444;\n  vertical-align: top;\n}\n\n.lm-wrapper .lm-table tr:nth-child(even) td {\n  background: #f8fafd;\n}\n\n.lm-wrapper .lm-table tr.lm-total-row td {\n  background: #eef5ff;\n  font-weight: 700;\n  color: #0d2b5e;\n  border-bottom: none;\n}\n\n.lm-wrapper .lm-table td.lm-num {\n  text-align: right;\n  font-variant-numeric: tabular-nums;\n}\n\n.lm-wrapper .lm-table td.lm-center {\n  text-align: center;\n}\n\n.lm-wrapper .lm-table td.lm-green {\n  color: #27ae60;\n  font-weight: 700;\n}\n\n.lm-wrapper .lm-table td.lm-red {\n  color: #e74c3c;\n  font-weight: 700;\n}\n\n.lm-wrapper .lm-table td.lm-gold {\n  color: #c8a44e;\n  font-weight: 700;\n}\n\n.lm-wrapper .lm-table td.lm-winner {\n  color: #c8a44e;\n  font-weight: 700;\n  font-size: 13px;\n}\n\n\/* ============================================================\n   \u4e09\u65b9\u6848\u5361\u7247\u7f51\u683c\n   ============================================================ *\/\n.lm-wrapper .lm-plan-grid-3 {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 18px;\n  margin: 20px 0;\n}\n\n.lm-wrapper .lm-plan-card-3 {\n  border-radius: 12px;\n  overflow: hidden;\n  box-shadow: 0 4px 18px rgba(0,0,0,0.09);\n  background: #ffffff;\n  border: 1px solid #e8edf5;\n  position: relative;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-card-header {\n  padding: 20px 18px 16px;\n  color: #ffffff;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-card-header h3 {\n  font-size: 16px;\n  font-weight: 700;\n  margin: 0 0 6px;\n  color: #ffffff;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-card-header p {\n  font-size: 13px;\n  opacity: 0.9;\n  margin: 0;\n}\n\n.lm-wrapper .lm-plan-card-3.lm-plan-a .lm-plan-card-header {\n  background: linear-gradient(135deg, #2563eb, #1d4ed8);\n}\n\n.lm-wrapper .lm-plan-card-3.lm-plan-b .lm-plan-card-header {\n  background: linear-gradient(135deg, #0d9488, #0f766e);\n}\n\n.lm-wrapper .lm-plan-card-3.lm-plan-c .lm-plan-card-header {\n  background: linear-gradient(135deg, #b45309, #d97706);\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-card-body {\n  padding: 16px 18px 20px;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-card-body h4 {\n  font-size: 12px;\n  font-weight: 700;\n  color: #888888;\n  letter-spacing: 1px;\n  text-transform: uppercase;\n  margin: 12px 0 6px;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-price {\n  font-size: 24px;\n  font-weight: 800;\n  color: #dc2626;\n  text-align: center;\n  padding: 10px 0;\n  background: #fff8f8;\n  border-radius: 8px;\n  border: 1px dashed #fca5a5;\n  margin: 12px 0;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-price span {\n  font-size: 14px;\n  font-weight: 400;\n  color: #888888;\n  margin-left: 2px;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-rec-badge {\n  position: absolute;\n  top: -1px;\n  right: 16px;\n  background: #fcd34d;\n  color: #92400e;\n  font-size: 11px;\n  font-weight: 700;\n  padding: 3px 12px;\n  border-radius: 0 0 8px 8px;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-features {\n  margin: 0;\n  padding: 0;\n  list-style: none;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-features li {\n  font-size: 13px;\n  padding: 3px 0 3px 18px;\n  position: relative;\n  color: #374151;\n  line-height: 1.6;\n}\n\n.lm-wrapper .lm-plan-card-3 .lm-plan-features li::before {\n  content: \"\u2713\";\n  position: absolute;\n  left: 0;\n  color: #27ae60;\n  font-weight: 700;\n}\n\n\/* ============================================================\n   \u4e09\u65b9\u6848\u603b\u4ef7\u5361\u7247\n   ============================================================ *\/\n.lm-wrapper .lm-price-compare-3 {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 18px;\n  margin: 20px 0;\n}\n\n.lm-wrapper .lm-price-card-3 {\n  border-radius: 14px;\n  padding: 24px 20px;\n  text-align: center;\n}\n\n.lm-wrapper .lm-price-card-3.lm-price-a {\n  background: linear-gradient(135deg, #eff6ff, #dbeafe);\n  border: 2px solid #93c5fd;\n}\n\n.lm-wrapper .lm-price-card-3.lm-price-b {\n  background: linear-gradient(135deg, #f0fdfa, #ccfbf1);\n  border: 2px solid #5eead4;\n}\n\n.lm-wrapper .lm-price-card-3.lm-price-c {\n  background: linear-gradient(135deg, #fffbeb, #fef3c7);\n  border: 2px solid #fcd34d;\n}\n\n.lm-wrapper .lm-price-card-3 .lm-price-card-label {\n  font-size: 13px;\n  font-weight: 700;\n  letter-spacing: 1px;\n  color: #6b7280;\n  margin-bottom: 6px;\n}\n\n.lm-wrapper .lm-price-card-3 .lm-price-card-name {\n  font-size: 14px;\n  font-weight: 700;\n  color: #1f2937;\n  margin-bottom: 12px;\n}\n\n.lm-wrapper .lm-price-card-3 .lm-price-card-amount {\n  font-size: 30px;\n  font-weight: 900;\n  color: #dc2626;\n  display: block;\n  margin-bottom: 4px;\n}\n\n.lm-wrapper .lm-price-card-3 .lm-price-card-tag {\n  display: inline-block;\n  padding: 4px 14px;\n  border-radius: 12px;\n  font-size: 12px;\n  font-weight: 600;\n  margin-top: 8px;\n}\n\n.lm-wrapper .lm-price-a .lm-price-card-tag {\n  background: #dbeafe;\n  color: #1d4ed8;\n}\n\n.lm-wrapper .lm-price-b .lm-price-card-tag {\n  background: #ccfbf1;\n  color: #0f766e;\n}\n\n.lm-wrapper .lm-price-c .lm-price-card-tag {\n  background: #fef3c7;\n  color: #92400e;\n}\n\n\/* ============================================================\n   \u661f\u7ea7\u8bc4\u5206\n   ============================================================ *\/\n.lm-wrapper .lm-stars {\n  color: #f59e0b;\n  letter-spacing: 1px;\n}\n\n.lm-wrapper .lm-stars-gray {\n  color: #d1d5db;\n  letter-spacing: 1px;\n}\n\n\/* ============================================================\n   \u8bf4\u660e\u6846 \/ \u63d0\u793a\u6846\n   ============================================================ *\/\n.lm-wrapper .lm-tip {\n  background: #fffbeb;\n  border-left: 4px solid #f59e0b;\n  border-radius: 0 8px 8px 0;\n  padding: 14px 18px;\n  margin: 14px 0;\n  font-size: 14px;\n  color: #92400e;\n  line-height: 1.6;\n}\n\n.lm-wrapper .lm-tip strong {\n  font-weight: 700;\n}\n\n.lm-wrapper .lm-note {\n  background: #f0fdf4;\n  border-left: 4px solid #22c55e;\n  border-radius: 0 8px 8px 0;\n  padding: 14px 18px;\n  margin: 14px 0;\n  font-size: 14px;\n  color: #14532d;\n}\n\n.lm-wrapper .lm-info-box {\n  background: #f0f7ff;\n  border-left: 4px solid #3b82f6;\n  border-radius: 0 8px 8px 0;\n  padding: 14px 18px;\n  margin: 14px 0;\n  font-size: 14px;\n  color: #1e40af;\n  line-height: 1.6;\n}\n\n.lm-wrapper .lm-warn-box {\n  background: #fef2f2;\n  border-left: 4px solid #ef4444;\n  border-radius: 0 8px 8px 0;\n  padding: 14px 18px;\n  margin: 14px 0;\n  font-size: 14px;\n  color: #991b1b;\n  line-height: 1.6;\n}\n\n\/* ============================================================\n   \u8d85\u914d\u7387\u63d0\u793a\u6846\n   ============================================================ *\/\n.lm-wrapper .lm-ratio-box {\n  background: #f0f7ff;\n  border: 1px solid #bfdbfe;\n  border-radius: 8px;\n  padding: 12px 16px;\n  margin: 12px 0;\n  display: flex;\n  align-items: flex-start;\n  gap: 8px;\n}\n\n.lm-wrapper .lm-ratio-box .lm-ratio-icon {\n  font-size: 18px;\n  flex-shrink: 0;\n  margin-top: 1px;\n}\n\n.lm-wrapper .lm-ratio-box p {\n  margin: 0;\n  font-size: 14px;\n  color: #1e40af;\n  line-height: 1.6;\n}\n\n\/* ============================================================\n   \u6807\u7b7e\n   ============================================================ *\/\n.lm-wrapper .lm-tag {\n  display: inline-block;\n  padding: 3px 10px;\n  border-radius: 10px;\n  font-size: 12px;\n  font-weight: 600;\n  margin: 2px 4px 2px 0;\n  white-space: nowrap;\n}\n\n.lm-wrapper .lm-tag.blue {\n  background: #dbeafe;\n  color: #1d4ed8;\n}\n\n.lm-wrapper .lm-tag.gold {\n  background: #fef3c7;\n  color: #92400e;\n}\n\n.lm-wrapper .lm-tag.green {\n  background: #dcfce7;\n  color: #166534;\n}\n\n\/* ============================================================\n   \u63a8\u8350\u6587\u6848\u5361\u7247\n   ============================================================ *\/\n.lm-wrapper .lm-recommend-card {\n  border-radius: 12px;\n  padding: 24px;\n  margin: 20px 0;\n  background: linear-gradient(135deg, #fffbeb, #fef9e7);\n  border: 2px solid #fcd34d;\n}\n\n.lm-wrapper .lm-recommend-card h3 {\n  font-size: 18px;\n  font-weight: 700;\n  color: #92400e;\n  margin: 0 0 14px;\n}\n\n.lm-wrapper .lm-recommend-card p {\n  font-size: 14px;\n  color: #4a3728;\n  line-height: 1.8;\n  margin: 6px 0;\n}\n\n\/* ============================================================\n   \u6309\u94ae\u94fe\u63a5\n   ============================================================ *\/\n.lm-wrapper .lm-btn {\n  display: inline-block;\n  padding: 8px 18px;\n  border-radius: 6px;\n  font-size: 13px;\n  font-weight: 600;\n  text-decoration: none;\n  color: #ffffff;\n  background: linear-gradient(135deg, #0d2b5e, #1a4a8a);\n  margin: 4px 6px 4px 0;\n  cursor: pointer;\n}\n\n.lm-wrapper .lm-btn.gold {\n  background: linear-gradient(135deg, #b45309, #d97706);\n}\n\n\/* ============================================================\n   \u670d\u52a1\u627f\u8bfa\u7f51\u683c\n   ============================================================ *\/\n.lm-wrapper .lm-service-grid {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 14px;\n  margin: 16px 0;\n}\n\n.lm-wrapper .lm-service-item {\n  background: #f8fafd;\n  border-radius: 10px;\n  padding: 18px 16px;\n  border: 1px solid #e5e7eb;\n  text-align: center;\n}\n\n.lm-wrapper .lm-service-item .lm-service-icon {\n  font-size: 24px;\n  display: block;\n  margin-bottom: 8px;\n}\n\n.lm-wrapper .lm-service-item h4 {\n  font-size: 14px;\n  font-weight: 700;\n  color: #0d2b5e;\n  margin: 0 0 6px;\n}\n\n.lm-wrapper .lm-service-item p {\n  font-size: 13px;\n  color: #6b7280;\n  margin: 0;\n  line-height: 1.5;\n}\n\n\/* ============================================================\n   \u4f1a\u5458\u6743\u76ca\u533a\n   ============================================================ *\/\n.lm-wrapper .lm-member-box {\n  background: linear-gradient(135deg, #0d2b5e, #1a4a8a);\n  color: #ffffff;\n  border-radius: 12px;\n  padding: 28px 30px;\n  margin: 20px 0;\n}\n\n.lm-wrapper .lm-member-box h3 {\n  font-size: 18px;\n  font-weight: 700;\n  color: #fcd34d;\n  margin: 0 0 16px;\n}\n\n.lm-wrapper .lm-member-grid {\n  display: grid;\n  grid-template-columns: repeat(3, 1fr);\n  gap: 16px;\n  margin-top: 16px;\n}\n\n.lm-wrapper .lm-member-item {\n  background: rgba(255,255,255,0.1);\n  border-radius: 8px;\n  padding: 14px;\n  border: 1px solid rgba(255,255,255,0.15);\n  text-align: center;\n}\n\n.lm-wrapper .lm-member-item .lm-member-label {\n  font-size: 12px;\n  opacity: 0.8;\n  margin-bottom: 6px;\n  display: block;\n}\n\n.lm-wrapper .lm-member-item .lm-member-value {\n  font-size: 15px;\n  font-weight: 700;\n  color: #fcd34d;\n}\n\n\/* ============================================================\n   \u5e95\u90e8 Footer\n   ============================================================ *\/\n.lm-wrapper .lm-footer {\n  background: linear-gradient(135deg, #0d2b5e, #1a3a6b);\n  color: #ffffff;\n  padding: 36px 32px;\n  text-align: center;\n}\n\n.lm-wrapper .lm-footer h3 {\n  font-size: 18px;\n  font-weight: 700;\n  color: #fcd34d;\n  margin: 0 0 20px;\n}\n\n.lm-wrapper .lm-footer-prices {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  justify-content: center;\n  margin-bottom: 20px;\n}\n\n.lm-wrapper .lm-footer-prices span {\n  background: rgba(255,255,255,0.1);\n  border-radius: 6px;\n  padding: 6px 14px;\n  font-size: 13px;\n}\n\n.lm-wrapper .lm-footer-tagline {\n  font-size: 13px;\n  opacity: 0.7;\n  margin-top: 20px;\n  padding-top: 20px;\n  border-top: 1px solid rgba(255,255,255,0.1);\n}\n\n\/* ============================================================\n   \u54cd\u5e94\u5f0f\n   ============================================================ *\/\n@media (max-width: 1024px) {\n  .lm-wrapper .lm-plan-grid-3,\n  .lm-wrapper .lm-price-compare-3 {\n    grid-template-columns: repeat(2, 1fr);\n  }\n  \n  .lm-wrapper .lm-service-grid {\n    grid-template-columns: repeat(3, 1fr);\n  }\n  \n  .lm-wrapper .lm-member-grid {\n    grid-template-columns: repeat(3, 1fr);\n  }\n}\n\n@media (max-width: 739px) {\n  .lm-wrapper .lm-hero {\n    padding: 40px 20px 36px;\n  }\n  \n  .lm-wrapper .lm-hero h1 {\n    font-size: 24px;\n  }\n  \n  .lm-wrapper .lm-hero-meta {\n    flex-direction: column;\n    align-items: center;\n  }\n  \n  .lm-wrapper .lm-section {\n    padding: 24px 18px;\n  }\n  \n  .lm-wrapper .lm-plan-grid-3,\n  .lm-wrapper .lm-price-compare-3 {\n    grid-template-columns: 1fr;\n  }\n  \n  .lm-wrapper .lm-service-grid {\n    grid-template-columns: repeat(2, 1fr);\n  }\n  \n  .lm-wrapper .lm-member-grid {\n    grid-template-columns: 1fr;\n  }\n  \n  .lm-wrapper .lm-table-wrap {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n  }\n}\n\n@media print {\n  .lm-wrapper {\n    max-width: 100%;\n  }\n  \n  .lm-wrapper .lm-hero {\n    break-after: page;\n  }\n  \n  .lm-wrapper .lm-section {\n    break-inside: avoid;\n  }\n}\n<\/style>\n\n<!-- ============================================================\n     \u5c01\u9762 \u00b7 Hero Section\n     ============================================================ -->\n<div class=\"lm-hero\" id=\"lm-top\">\n  <div class=\"lm-hero-brand\">LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a \u00b7 \u59cb\u4e8e2004 \u00b7 \u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd22\u5e74<\/div>\n  <h1>\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6<br>\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848<\/h1>\n  <div class=\"lm-hero-sub\">\u4e00\u697c\u8212\u4eab\u7eaf\u6c1f\u7a7a\u8c03 + \u4e8c\u697c\u00b7\u4e09\u697c\u72ec\u7acb\u7cfb\u7edf<br>\u4e09\u5927\u65b9\u6848\u5168\u7ef4\u5ea6\u5bf9\u6bd4 \u00b7 15\u5929\u6709\u6548\u62a5\u4ef7<\/div>\n  \n  <div class=\"lm-hero-meta\">\n    <div class=\"lm-hero-meta-item\"><strong>\ud83c\udfe0 \u5ba2\u6237<\/strong>\u5c0f\u5468\u8001\u5e08\uff086\u4eba\u5bb6\u5ead\uff09<\/div>\n    <div class=\"lm-hero-meta-item\"><strong>\ud83d\udccd \u5730\u5740<\/strong>\u9f99\u6e56\u4e09\u5343\u96c6\uff08\u8054\u6392\u53e0\u62fc\u4e0a\u53e0\u00b7\u4e09\u5c42\uff09<\/div>\n    <div class=\"lm-hero-meta-item\"><strong>\ud83d\udc64 \u987e\u95ee<\/strong>\u9f99\u8109\u6696\u901a\u00b7\u9ec4\u52c7<\/div>\n    <div class=\"lm-hero-meta-item\"><strong>\ud83d\udcc5 \u65e5\u671f<\/strong>2026\u5e746\u670810\u65e5<\/div>\n    <div class=\"lm-hero-meta-item\"><strong>\u23f0 \u6709\u6548\u671f<\/strong>\u81f32026\u5e746\u670825\u65e5<\/div>\n  <\/div>\n\n  <div class=\"lm-anchor-nav\">\n    <span class=\"lm-anchor-btn\">\u9700\u6c42\u75db\u70b9<\/span>\n    <span class=\"lm-anchor-btn\">\u65b9\u6848\u5dee\u5f02<\/span>\n    <span class=\"lm-anchor-btn\">\u6237\u578b\u914d\u7f6e<\/span>\n    <span class=\"lm-anchor-btn\">\u900f\u660e\u62a5\u4ef7<\/span>\n    <span class=\"lm-anchor-btn\">\u603b\u4ef7\u5bf9\u6bd4<\/span>\n    <span class=\"lm-anchor-btn\">\u9009\u578b\u5efa\u8bae<\/span>\n    <span class=\"lm-anchor-btn\">\u670d\u52a1\u4fdd\u969c<\/span>\n  <\/div>\n  \n  <div class=\"lm-hero-tagline\">\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002\ud83c\udfe1<\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u4e00\u3001\u9700\u6c42\u4e0e\u75db\u70b9\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u4e00<\/span>\n    <h2>\u60a8\u7684\u9700\u6c42\u4e0e\u75db\u70b9<\/h2>\n  <\/div>\n  <p class=\"lm-section-desc\">6\u4eba\u5927\u5bb6\u5ead\uff0c\u4e09\u5c42\u8054\u6392\u53e0\u62fc\u4e0a\u53e0\uff0c\u9700\u8981\u4e00\u5957\u771f\u6b63\u7701\u5fc3\u3001\u7701\u94b1\u3001\u8212\u9002\u7684\u6696\u901a\u65b9\u6848\u3002<\/p>\n  \n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u5206\u7c7b<\/th>\n          <th>\u60a8\u7684\u9700\u6c42 \/ \u75db\u70b9<\/th>\n          <th>\u6211\u4eec\u7684\u89e3\u51b3\u65b9\u6848<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u6838\u5fc3\u9700\u6c42<\/strong><\/td>\n          <td>\u4e09\u5c42\u697c\u5168\u5c4b\u7a7a\u8c03 + \u5730\u6696\uff0c6\u4eba\u5bb6\u5ead<\/td>\n          <td>\u4e00\u697c\u72ec\u7acb\u7eaf\u6c1f\u7a7a\u8c03\uff0c\u4e8c\u697c+\u4e09\u697c\u72ec\u7acb\u7cfb\u7edf\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u5236<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u4f7f\u7528\u4e60\u60ef<\/strong><\/td>\n          <td>6\u4eba\u5bb6\u5ead\uff0c\u4f7f\u7528\u533a\u57df\u5206\u6563<\/td>\n          <td>\u4e24\u5957\u72ec\u7acb\u7cfb\u7edf\uff0c\u6309\u9700\u5f00\u542f\uff0c\u6781\u81f4\u8282\u80fd<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5730\u6696\u9700\u6c42<\/strong><\/td>\n          <td>\u4e09\u5c42\u697c\u5168\u5c4b\u5730\u6696\uff08\u7ea6191.5\u33a1\uff09<\/td>\n          <td>\u65b9\u6848\u4e00\uff1a\u535a\u4e16\u9505\u7089\uff1b\u65b9\u6848\u4e8c\/\u4e09\uff1a\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5\uff0c\u7edf\u4e00\u94fa\u8bbe<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n          <td>6\u4eba\u5bb6\u5ead\u70ed\u6c34\u9700\u6c42<\/td>\n          <td>\u65b9\u6848\u4e00\uff1a\u9505\u7089\u4e00\u4f53\u4f9b\u5e94\uff1b\u65b9\u6848\u4e8c\/\u4e09\uff1a\u63a8\u8350\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5bf9\u6bd4\u9700\u6c42<\/strong><\/td>\n          <td>\u5bf9\u6bd4\u4e09\u79cd\u65b9\u6848<\/td>\n          <td>\u4f20\u7edf\u9505\u7089 \/ VAM mini\u4e24\u8054\u4f9b \/ \u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u4e8c\u3001\u6237\u578b\u4e0e\u914d\u7f6e\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u4e8c<\/span>\n    <h2>\u6237\u578b\u4e0e\u914d\u7f6e<\/h2>\n  <\/div>\n\n  <div class=\"lm-sub-title\">\u7cfb\u7edf\u4e00\uff1a\u4e00\u697c\uff08\u7eaf\u6c1f\u4e2d\u592e\u7a7a\u8c03\uff09\u2014 \u8212\u4eab\u7cfb\u5217\uff08\u4e09\u65b9\u6848\u76f8\u540c\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u533a\u57df<\/th>\n          <th class=\"lm-num\">\u9762\u79ef(\u33a1)<\/th>\n          <th>\u5185\u673a\u578b\u53f7<\/th>\n          <th class=\"lm-center\">\u6570\u91cf<\/th>\n          <th class=\"lm-num\">\u5bb9\u91cf<\/th>\n          <th class=\"lm-num\">\u5355\u4f4d\u51b7\u8d1f\u8377<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5ba2\u5385+\u8fc7\u9053+\u8863\u5e3d\u95f4\uff08\u8fde\u901a\uff09<\/td>\n          <td class=\"lm-num\">77<\/td>\n          <td>RPIZ-71FSNAQD\/P<\/td>\n          <td class=\"lm-center\">2\u53f0<\/td>\n          <td class=\"lm-num\">7.1kW\u00d72<\/td>\n          <td class=\"lm-num\">\u7ea6184W\/\u33a1<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e66\u623f<\/td>\n          <td class=\"lm-num\">11<\/td>\n          <td>RPIZ-18FSNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">1.8kW<\/td>\n          <td class=\"lm-num\">\u7ea6164W\/\u33a1<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td><strong>\u5185\u673a\u5408\u8ba1<\/strong><\/td>\n          <td class=\"lm-num\"><strong>88<\/strong><\/td>\n          <td>\u2014<\/td>\n          <td class=\"lm-center\"><strong>3\u53f0<\/strong><\/td>\n          <td class=\"lm-num\"><strong>16.0kW<\/strong><\/td>\n          <td>\u2014<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-ratio-box\">\n    <span class=\"lm-ratio-icon\">\u2699\ufe0f<\/span>\n    <p><strong>\u5916\u673a\uff1aRAS-140HRNAQ\uff08\u8212\u4eab140\u578b\uff0c14.0kW\uff09| \u8d85\u914d\u7387\uff1a114%<\/strong>\uff08\u9ec4\u91d1\u533a\u95f4\uff0c\u7cfb\u7edf\u8fd0\u884c\u9ad8\u6548\u7a33\u5b9a\uff09<\/p>\n  <\/div>\n\n  <div class=\"lm-sub-title\">\u7cfb\u7edf\u4e8c\uff1a\u4e8c\u697c+\u4e09\u697c \u2014 \u4e09\u65b9\u6848\u5185\u673a\u5bb9\u91cf\u76f8\u540c\uff0c\u578b\u53f7\u4e0d\u540c<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u697c\u5c42<\/th>\n          <th>\u533a\u57df<\/th>\n          <th class=\"lm-num\">\u9762\u79ef(\u33a1)<\/th>\n          <th class=\"lm-num\">\u5bb9\u91cf<\/th>\n          <th>\u65b9\u6848\u4e00\u578b\u53f7\uff08\u8212\u4eab\uff09<\/th>\n          <th>\u65b9\u6848\u4e8c\u578b\u53f7\uff08VAM mini\uff09<\/th>\n          <th>\u65b9\u6848\u4e09\u578b\u53f7\uff08\u5c0a\u777f\u4e09\u7ba1\u5236\uff09<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u4e8c\u697c<\/td>\n          <td>\u8863\u5e3d\u95f4<\/td>\n          <td class=\"lm-num\">12.5<\/td>\n          <td class=\"lm-num\">22\uff082.2kW\uff09<\/td>\n          <td>RPIZ-22FSNAQD\/P<\/td>\n          <td>RPIZ-22FSVNAQD\/P<\/td>\n          <td>RPIZ-22FSVN2QB\/PC<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e8c\u697c<\/td>\n          <td>\u4e3b\u5367\u5ba4<\/td>\n          <td class=\"lm-num\">21<\/td>\n          <td class=\"lm-num\">45\uff084.5kW\uff09<\/td>\n          <td>RPIZ-45FSNAQD\/P<\/td>\n          <td>RPIZ-45FSVNAQD\/P<\/td>\n          <td>RPIZ-45FSVN2QB\/PC<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e8c\u697c<\/td>\n          <td>\u6b21\u53671<\/td>\n          <td class=\"lm-num\">20<\/td>\n          <td class=\"lm-num\">40\uff084.0kW\uff09<\/td>\n          <td>RPIZ-40FSNAQD\/P<\/td>\n          <td>RPIZ-40FSVNAQD\/P<\/td>\n          <td>RPIZ-40FSVN2QB\/PC<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e8c\u697c<\/td>\n          <td>\u6b21\u53672<\/td>\n          <td class=\"lm-num\">19<\/td>\n          <td class=\"lm-num\">40\uff084.0kW\uff09<\/td>\n          <td>RPIZ-40FSNAQD\/P<\/td>\n          <td>RPIZ-40FSVNAQD\/P<\/td>\n          <td>RPIZ-40FSVN2QB\/PC<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e09\u697c<\/td>\n          <td>\u5957\u623f<\/td>\n          <td class=\"lm-num\">31<\/td>\n          <td class=\"lm-num\">63\uff086.3kW\uff09<\/td>\n          <td>RPIZ-63FSNAQD\/P<\/td>\n          <td>RPIZ-63FSVNAQD\/P<\/td>\n          <td>RPIZ-63FSVN2QB\/PC<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td><strong>\u5185\u673a\u5408\u8ba1<\/strong><\/td>\n          <td>\u2014<\/td>\n          <td>\u2014<\/td>\n          <td class=\"lm-num\"><strong>5\u53f0 \u00b7 19.8kW<\/strong><\/td>\n          <td><strong>5\u53f0<\/strong><\/td>\n          <td><strong>5\u53f0<\/strong><\/td>\n          <td><strong>5\u53f0<\/strong><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-sub-title\">\u5168\u5c4b\u5730\u6696\u7cfb\u7edf\uff08\u8282\u80fd\u8bbe\u8ba1\u6a21\u5f0f\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u4e00\u697c<\/th>\n          <th>\u4e8c\u697c+\u4e09\u697c<\/th>\n          <th>\u5168\u5c4b\u5408\u8ba1<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u91c7\u6696\u9762\u79ef<\/strong><\/td>\n          <td class=\"lm-num\">88 \u33a1<\/td>\n          <td class=\"lm-num\">\u7ea6103.5 \u33a1<\/td>\n          <td class=\"lm-num\"><strong>\u7ea6191.5 \u33a1<\/strong><\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u65b9\u6848\u4e00\u70ed\u6e90<\/strong><\/td>\n          <td colspan=\"3\">\u535a\u4e16G6100\u4e24\u7528\u7089\uff08\u9505\u70895,850\u5143+\u5b89\u88c5600\u5143+\u4e8c\u6b21\u7cfb\u7edf3,000\u5143\uff0c\u5730\u6696\u94fa\u8bbe120\u5143\/\u33a1\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u65b9\u6848\u4e8c\/\u4e09\u70ed\u6e90<\/strong><\/td>\n          <td colspan=\"3\">\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5\uff08\u5355\u4ef7169\u5143\/\u33a1\uff0c\u542b\u4e3b\u7ba1\u3001\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u3001\u4fdd\u6e29\u3001\u53cd\u5c04\u819c\u3001\u56de\u586b\u3001\u8054\u52a8\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5e03\u7ba1\u65b9\u5f0f<\/strong><\/td>\n          <td>\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668<\/td>\n          <td>\u7ae0\u9c7c\u5f0f\u5206\u96c6\u6c34\u5668<\/td>\n          <td>\u7edf\u4e00\u8054\u52a8\u63a7\u5236<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u63a7\u5236\u65b9\u5f0f<\/strong><\/td>\n          <td>\u66fc\u745e\u5fb7\u8054\u52a8+WiFi<\/td>\n          <td>\u66fc\u745e\u5fb7\u8054\u52a8+WiFi<\/td>\n          <td>\u4e0e\u70ed\u6e90\u4e3b\u673a\u8054\u52a8<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u4e09\u3001\u900f\u660e\u62a5\u4ef7\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u4e09<\/span>\n    <h2>\u900f\u660e\u62a5\u4ef7<\/h2>\n  <\/div>\n\n  <div class=\"lm-sub-title\">\u6298\u6263\u89c4\u5219\u8bf4\u660e<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u7cfb\u5217<\/th>\n          <th>\u6298\u6263<\/th>\n          <th>\u9002\u7528\u8303\u56f4<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u8212\u4eab\u7cfb\u5217<\/strong><\/td>\n          <td class=\"lm-green\">8\u6298<\/td>\n          <td>\u65b9\u6848\u4e00\/\u4e8c\/\u4e09 \u7cfb\u7edf\u4e00\uff1b\u65b9\u6848\u4e00 \u7cfb\u7edf\u4e8c<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>VAM mini\u7cfb\u5217<\/strong><\/td>\n          <td class=\"lm-green\">8\u6298<\/td>\n          <td>\u65b9\u6848\u4e8c \u7cfb\u7edf\u4e8c\uff08\u5916\u673a+\u5185\u673a+\u6c34\u6a21\u5757\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5c0a\u777f\u5168\u6548\u7cfb\u5217<\/strong><\/td>\n          <td style=\"color:#e67e22;font-weight:700;\">8.5\u6298<\/td>\n          <td>\u65b9\u6848\u4e09 \u7cfb\u7edf\u4e8c\uff08\u5916\u673a+\u5185\u673a+\u6c34\u6a21\u5757\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5b89\u88c5\u8d39\u3001\u7ebf\u63a7\u5668\u3001\u5730\u6696<\/strong><\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td>\u6240\u6709\u65b9\u6848<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u7cfb\u7edf\u4e00\u56fa\u5b9a\u62a5\u4ef7 -->\n  <div class=\"lm-sub-title\">\u7cfb\u7edf\u4e00\uff08\u4e00\u697c\uff09\u56fa\u5b9a\u62a5\u4ef7 \u2014 \u4e09\u65b9\u6848\u76f8\u540c<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u578b\u53f7\/\u89c4\u683c<\/th>\n          <th class=\"lm-center\">\u6570\u91cf<\/th>\n          <th class=\"lm-num\">\u9762\u4ef7(\u5143)<\/th>\n          <th>\u6298\u6263<\/th>\n          <th class=\"lm-num\">\u6298\u540e(\u5143)<\/th>\n          <th class=\"lm-num\">\u5c0f\u8ba1(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a<\/td>\n          <td>RAS-140HRNAQ\uff08\u8212\u4eab140\u578b\uff09<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">12,875<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">10,300<\/td>\n          <td class=\"lm-num\">10,300<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a71<\/td>\n          <td>RPIZ-71FSNAQD\/P<\/td>\n          <td class=\"lm-center\">2\u53f0<\/td>\n          <td class=\"lm-num\">3,513<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">2,810<\/td>\n          <td class=\"lm-num\">5,620<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a18<\/td>\n          <td>RPIZ-18FSNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">2,838<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">2,270<\/td>\n          <td class=\"lm-num\">2,270<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ebf\u63a7\u5668<\/td>\n          <td>PC-P1HVQA\uff08WiFi\u578b\uff09<\/td>\n          <td class=\"lm-center\">3\u4e2a<\/td>\n          <td class=\"lm-num\">200<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">200<\/td>\n          <td class=\"lm-num\">600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u8212\u4eab\u7cfb\u5217<\/td>\n          <td class=\"lm-center\">3\u53f0<\/td>\n          <td class=\"lm-num\">1,600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">1,600<\/td>\n          <td class=\"lm-num\">4,800<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5916\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u6c1f\u7cfb\u7edf\u5916\u673a<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td class=\"lm-num\">600<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td colspan=\"6\"><strong>\u7cfb\u7edf\u4e00\u5408\u8ba1<\/strong><\/td>\n          <td class=\"lm-num\"><strong>24,190<\/strong><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u65b9\u6848\u4e00\u62a5\u4ef7 -->\n  <div class=\"lm-sub-title\">\u65b9\u6848\u4e00\uff1a\u8212\u4eab180\u7eaf\u6c1f\u7a7a\u8c03\uff088\u6298\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u578b\u53f7\/\u89c4\u683c<\/th>\n          <th class=\"lm-center\">\u6570\u91cf<\/th>\n          <th class=\"lm-num\">\u9762\u4ef7(\u5143)<\/th>\n          <th>\u6298\u6263<\/th>\n          <th class=\"lm-num\">\u6298\u540e(\u5143)<\/th>\n          <th class=\"lm-num\">\u5c0f\u8ba1(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a<\/td>\n          <td>RAS-180HRNAQ\uff08\u8212\u4eab180\u578b\uff0c18.0kW\uff09<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">16,150<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">12,920<\/td>\n          <td class=\"lm-num\">12,920<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a22\u578b<\/td>\n          <td>RPIZ-22FSNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">2,838<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">2,270<\/td>\n          <td class=\"lm-num\">2,270<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a45\u578b<\/td>\n          <td>RPIZ-45FSNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">3,250<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">2,600<\/td>\n          <td class=\"lm-num\">2,600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a40\u578b<\/td>\n          <td>RPIZ-40FSNAQD\/P<\/td>\n          <td class=\"lm-center\">2\u53f0<\/td>\n          <td class=\"lm-num\">3,125<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">2,500<\/td>\n          <td class=\"lm-num\">5,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a63\u578b<\/td>\n          <td>RPIZ-63FSNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">3,463<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">2,770<\/td>\n          <td class=\"lm-num\">2,770<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ebf\u63a7\u5668<\/td>\n          <td>PC-P1HVQA\uff08WiFi\u578b\uff09<\/td>\n          <td class=\"lm-center\">5\u4e2a<\/td>\n          <td class=\"lm-num\">200<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">200<\/td>\n          <td class=\"lm-num\">1,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u6c1f\u7cfb\u7edf\u5185\u673a<\/td>\n          <td class=\"lm-center\">5\u53f0<\/td>\n          <td class=\"lm-num\">1,600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">1,600<\/td>\n          <td class=\"lm-num\">8,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5916\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u6c1f\u7cfb\u7edf\u5916\u673a<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td class=\"lm-num\">600<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td colspan=\"6\"><strong>\u65b9\u6848\u4e00 \u00b7 \u7cfb\u7edf\u4e8c\u5408\u8ba1<\/strong><\/td>\n          <td class=\"lm-num\"><strong>35,160<\/strong><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u65b9\u6848\u4e8c\u62a5\u4ef7 -->\n  <div class=\"lm-sub-title\">\u65b9\u6848\u4e8c\uff1aVAM mini II + \u6c34\u6a21\u5757\uff08\u5916\u673a+\u5185\u673a+\u6c34\u6a21\u5757 8\u6298\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u578b\u53f7\/\u89c4\u683c<\/th>\n          <th class=\"lm-center\">\u6570\u91cf<\/th>\n          <th class=\"lm-num\">\u9762\u4ef7(\u5143)<\/th>\n          <th>\u6298\u6263<\/th>\n          <th class=\"lm-num\">\u6298\u540e(\u5143)<\/th>\n          <th class=\"lm-num\">\u5c0f\u8ba1(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a<\/td>\n          <td>RAS-200FSVN8Q\uff08VAM mini 200\u578b\uff0c20.0kW\uff09<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">29,600<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">23,680<\/td>\n          <td class=\"lm-num\">23,680<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757<\/td>\n          <td>RWMG-200FWNZ1Q<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">11,263<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">9,010<\/td>\n          <td class=\"lm-num\">9,010<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757\u5b89\u88c5\u8d39<\/td>\n          <td>\u6807\u51c6\u5b89\u88c5<\/td>\n          <td class=\"lm-center\">1\u5957<\/td>\n          <td class=\"lm-num\">625<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">625<\/td>\n          <td class=\"lm-num\">625<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a22\u578b<\/td>\n          <td>RPIZ-22FSVNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">4,113<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">3,290<\/td>\n          <td class=\"lm-num\">3,290<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a45\u578b<\/td>\n          <td>RPIZ-45FSVNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">4,788<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">3,830<\/td>\n          <td class=\"lm-num\">3,830<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a40\u578b<\/td>\n          <td>RPIZ-40FSVNAQD\/P<\/td>\n          <td class=\"lm-center\">2\u53f0<\/td>\n          <td class=\"lm-num\">4,513<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">3,610<\/td>\n          <td class=\"lm-num\">7,220<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a63\u578b<\/td>\n          <td>RPIZ-63FSVNAQD\/P<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">4,963<\/td>\n          <td>8\u6298<\/td>\n          <td class=\"lm-num\">3,970<\/td>\n          <td class=\"lm-num\">3,970<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ebf\u63a7\u5668<\/td>\n          <td>PC-P1HVQA\uff08WiFi\u578b\uff09<\/td>\n          <td class=\"lm-center\">5\u4e2a<\/td>\n          <td class=\"lm-num\">200<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">200<\/td>\n          <td class=\"lm-num\">1,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u6c1f\u7cfb\u7edf\u5185\u673a<\/td>\n          <td class=\"lm-center\">5\u53f0<\/td>\n          <td class=\"lm-num\">1,600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">1,600<\/td>\n          <td class=\"lm-num\">8,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5916\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u6c1f\u7cfb\u7edf\u5916\u673a<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td class=\"lm-num\">600<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td colspan=\"6\"><strong>\u65b9\u6848\u4e8c \u00b7 \u7cfb\u7edf\u4e8c\u5408\u8ba1<\/strong><\/td>\n          <td class=\"lm-num\"><strong>61,225<\/strong><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u65b9\u6848\u4e09\u62a5\u4ef7 -->\n  <div class=\"lm-sub-title\">\u65b9\u6848\u4e09\uff1a\u5c0a\u777f\u5168\u6548\u2161 + \u6c34\u6a21\u5757\uff08\u5916\u673a+\u5185\u673a+\u6c34\u6a21\u5757 8.5\u6298\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u9879\u76ee<\/th>\n          <th>\u578b\u53f7\/\u89c4\u683c<\/th>\n          <th class=\"lm-center\">\u6570\u91cf<\/th>\n          <th class=\"lm-num\">\u9762\u4ef7(\u5143)<\/th>\n          <th>\u6298\u6263<\/th>\n          <th class=\"lm-num\">\u6298\u540e(\u5143)<\/th>\n          <th class=\"lm-num\">\u5c0f\u8ba1(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u5916\u673a<\/td>\n          <td>RAS-200FSXPN5Q\uff08\u5c0a\u777f\u5168\u6548\u2161\uff0c20kW\uff09<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">25,863<\/td>\n          <td>8.5\u6298<\/td>\n          <td class=\"lm-num\">21,983<\/td>\n          <td class=\"lm-num\">21,983<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757<\/td>\n          <td>RWMG-224FWXNZQ\uff08\u5c0a\u777f\u4e13\u7528\uff09<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">9,750<\/td>\n          <td>8.5\u6298<\/td>\n          <td class=\"lm-num\">8,288<\/td>\n          <td class=\"lm-num\">8,288<\/td>\n        <\/tr>\n        <tr>\n          <td>\u6c34\u6a21\u5757\u5b89\u88c5\u8d39<\/td>\n          <td>\u6807\u51c6\u5b89\u88c5<\/td>\n          <td class=\"lm-center\">1\u5957<\/td>\n          <td class=\"lm-num\">625<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">625<\/td>\n          <td class=\"lm-num\">625<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a22\u578b<\/td>\n          <td>RPIZ-22FSVN2QB\/PC<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">5,050<\/td>\n          <td>8.5\u6298<\/td>\n          <td class=\"lm-num\">4,293<\/td>\n          <td class=\"lm-num\">4,293<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a45\u578b<\/td>\n          <td>RPIZ-45FSVN2QB\/PC<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">5,563<\/td>\n          <td>8.5\u6298<\/td>\n          <td class=\"lm-num\">4,729<\/td>\n          <td class=\"lm-num\">4,729<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a40\u578b<\/td>\n          <td>RPIZ-40FSVN2QB\/PC<\/td>\n          <td class=\"lm-center\">2\u53f0<\/td>\n          <td class=\"lm-num\">5,238<\/td>\n          <td>8.5\u6298<\/td>\n          <td class=\"lm-num\">4,452<\/td>\n          <td class=\"lm-num\">8,904<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a63\u578b<\/td>\n          <td>RPIZ-63FSVN2QB\/PC<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">5,825<\/td>\n          <td>8.5\u6298<\/td>\n          <td class=\"lm-num\">4,951<\/td>\n          <td class=\"lm-num\">4,951<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7ebf\u63a7\u5668<\/td>\n          <td>PC-P1HPQA\uff08\u9ad8\u6e05\u5f69\u5c4f\uff09<\/td>\n          <td class=\"lm-center\">5\u4e2a<\/td>\n          <td class=\"lm-num\">420<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">420<\/td>\n          <td class=\"lm-num\">2,100<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5185\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u4e09\u7ba1\u5236\u5185\u673a<\/td>\n          <td class=\"lm-center\">5\u53f0<\/td>\n          <td class=\"lm-num\">1,900<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">1,900<\/td>\n          <td class=\"lm-num\">9,500<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5916\u673a\u5b89\u88c5\u8d39<\/td>\n          <td>\u6c1f\u7cfb\u7edf\u5916\u673a<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td class=\"lm-num\">600<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td colspan=\"6\"><strong>\u65b9\u6848\u4e09 \u00b7 \u7cfb\u7edf\u4e8c\u5408\u8ba1<\/strong><\/td>\n          <td class=\"lm-num\"><strong>65,973<\/strong><\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u5730\u6696\u7cfb\u7edf\u62a5\u4ef7 -->\n  <div class=\"lm-sub-title\">\u5730\u6696\u7cfb\u7edf\u62a5\u4ef7<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u65b9\u6848<\/th>\n          <th>\u9879\u76ee<\/th>\n          <th>\u578b\u53f7\/\u89c4\u683c<\/th>\n          <th class=\"lm-center\">\u6570\u91cf<\/th>\n          <th class=\"lm-num\">\u5355\u4ef7(\u5143)<\/th>\n          <th>\u6298\u6263<\/th>\n          <th class=\"lm-num\">\u5c0f\u8ba1(\u5143)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td rowspan=\"4\"><strong>\u65b9\u6848\u4e00<\/strong><\/td>\n          <td>\u535a\u4e16G6100\u4e24\u7528\u7089<\/td>\n          <td>Bosch G6100\uff0824kW\u4e24\u7528\u7089\uff09<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">5,850<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">5,850<\/td>\n        <\/tr>\n        <tr>\n          <td>\u9505\u7089\u5b89\u88c5\u8d39<\/td>\n          <td>\u6807\u51c6\u5b89\u88c5<\/td>\n          <td class=\"lm-center\">1\u53f0<\/td>\n          <td class=\"lm-num\">600<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">600<\/td>\n        <\/tr>\n        <tr>\n          <td>\u4e8c\u6b21\u7cfb\u7edf<\/td>\n          <td>\u6c34\u6cf5\u3001\u53bb\u8026\u7f50\u7b49<\/td>\n          <td class=\"lm-center\">1\u5957<\/td>\n          <td class=\"lm-num\">3,000<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">3,000<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5730\u6696\u94fa\u8bbe<\/td>\n          <td>\u5168\u5957\u5730\u6696\uff08191.5\u33a1\uff0c120\u5143\/\u33a1\uff09<\/td>\n          <td class=\"lm-center\">191.5\u33a1<\/td>\n          <td class=\"lm-num\">120<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">22,980<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td><strong>\u65b9\u6848\u4e00<\/strong><\/td>\n          <td colspan=\"5\">\u5730\u6696\u5c0f\u8ba1\uff08\u9505\u7089+\u4e8c\u6b21\u7cfb\u7edf+\u94fa\u8bbe\uff09<\/td>\n          <td class=\"lm-num\"><strong>32,430<\/strong><\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u65b9\u6848\u4e8c<\/strong><\/td>\n          <td>\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5\u5730\u6696<\/td>\n          <td>\u4e3b\u7ba1+\u76d8\u7ba1+\u5206\u96c6\u6c34\u5668+\u4fdd\u6e29+\u56de\u586b+\u8054\u52a8<\/td>\n          <td class=\"lm-center\">191.5\u33a1<\/td>\n          <td class=\"lm-num\">169<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">32,364<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u65b9\u6848\u4e09<\/strong><\/td>\n          <td>\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5\u5730\u6696<\/td>\n          <td>\u4e3b\u7ba1+\u76d8\u7ba1+\u5206\u96c6\u6c34\u5668+\u4fdd\u6e29+\u56de\u586b+\u8054\u52a8<\/td>\n          <td class=\"lm-center\">191.5\u33a1<\/td>\n          <td class=\"lm-num\">169<\/td>\n          <td>\u4e0d\u6253\u6298<\/td>\n          <td class=\"lm-num\">32,364<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tip\">\n    <strong>\ud83d\udccc \u65b9\u6848\u4e00\u5730\u6696\u8bf4\u660e\uff1a<\/strong>120\u5143\/\u33a1\u4e3a\u94fa\u8bbe\u5355\u4ef7\uff08\u4e0d\u542b\u9505\u7089\uff09\uff0c\u7efc\u5408\u62a5\u4ef7 = \u535a\u4e16G6100\u4e24\u7528\u7089\uff085,850\u5143\uff09+ \u9505\u7089\u5b89\u88c5\u8d39\uff08600\u5143\uff09+ \u4e8c\u6b21\u7cfb\u7edf\uff083,000\u5143\uff09+ \u5168\u5c4b\u5730\u6696\u94fa\u8bbe22,980\u5143 = <strong>32,430\u5143<\/strong>\u3002\u542b\u5168\u5c4b\u5730\u6696\u76d8\u7ba1\u3001\u5206\u96c6\u6c34\u5668\u3001\u4fdd\u6e29\u677f\u3001\u53cd\u5c04\u819c\u3001\u94a2\u4e1d\u7f51\u3001\u8fb9\u754c\u4fdd\u6e29\u6761\u3001\u56de\u586b\u627e\u5e73\u3001\u6e29\u63a7\u5668\u3001\u7535\u70ed\u6267\u884c\u5668\u3002\n  <\/div>\n\n  <div class=\"lm-info-box\">\n    <strong>\ud83d\udca1 \u751f\u6d3b\u70ed\u6c34\u63d0\u9192\uff1a<\/strong>\u65b9\u6848\u4e8c\/\u4e09\u9700\u72ec\u7acb\u914d\u7f6e\u751f\u6d3b\u70ed\u6c34\u5668\uff08\u63a8\u835020L\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u7ea63,000-5,000\u5143\uff09\uff0c\u65b9\u6848\u4e00\u70ed\u6c34\u7531\u9505\u7089\u4e00\u4f53\u4f9b\u5e94\u3002\n  <\/div>\n\n  <!-- \u9644\uff1a\u4e09\u5927\u65b9\u6848\u6838\u5fc3\u5dee\u5f02\u5316\u603b\u7ed3 -->\n  <div class=\"lm-sub-title\">\u9644\uff1a\u4e09\u5927\u65b9\u6848\u6838\u5fc3\u5dee\u5f02\u5316\u603b\u7ed3<\/div>\n  <div class=\"lm-plan-grid-3\">\n    <div class=\"lm-plan-card-3 lm-plan-a\">\n      <div class=\"lm-plan-card-header\">\n        <h3>\u65b9\u6848\u4e00 \u00b7 \u4f20\u7edf\u9505\u7089<\/h3>\n        <p>\u7cfb\u7edf\u7b80\u5355 \u00b7 \u70ed\u6c34\u4e00\u4f53 \u00b7 \u521d\u6295\u8d44\u6700\u4f4e<\/p>\n      <\/div>\n      <div class=\"lm-plan-card-body\">\n        <div class=\"lm-plan-price\">91,780 <span>\u5143<\/span><\/div>\n        <h4>\u6838\u5fc3\u914d\u7f6e<\/h4>\n        <ul class=\"lm-plan-features\">\n          <li>\u4e00\u697c\uff1a\u8212\u4eab140\u7eaf\u6c1f\u7a7a\u8c03<\/li>\n          <li>\u4e8c\u697c+\u4e09\u697c\uff1a\u8212\u4eab180\u7eaf\u6c1f\u7a7a\u8c03<\/li>\n          <li>\u5730\u6696\uff1a\u535a\u4e16G6100\u4e24\u7528\u7089<\/li>\n          <li>\u751f\u6d3b\u70ed\u6c34\uff1a\u9505\u7089\u4e00\u4f53\u4f9b\u5e94<\/li>\n          <li>\u5730\u6696\u5355\u4ef7\uff1a120\u5143\/\u33a1+\u9505\u7089<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-plan-card-3 lm-plan-b\">\n      <div class=\"lm-plan-card-header\">\n        <h3>\u65b9\u6848\u4e8c \u00b7 VAM mini\u4e24\u8054\u4f9b<\/h3>\n        <p>\u70ed\u6cf5\u5730\u6696 \u00b7 \u770140%-60% \u00b7 \u6027\u4ef7\u6bd4\u4e4b\u9009<\/p>\n      <\/div>\n      <div class=\"lm-plan-card-body\">\n        <div class=\"lm-plan-price\">117,779 <span>\u5143<\/span><\/div>\n        <h4>\u6838\u5fc3\u914d\u7f6e<\/h4>\n        <ul class=\"lm-plan-features\">\n          <li>\u4e00\u697c\uff1a\u8212\u4eab140\u7eaf\u6c1f\u7a7a\u8c03<\/li>\n          <li>\u4e8c\u697c+\u4e09\u697c\uff1aVAM mini 200\u578b+\u6c34\u6a21\u5757<\/li>\n          <li>\u5730\u6696\uff1a\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5<\/li>\n          <li>\u5185\u673a\uff1aDC\u6807\u51c6\u578b\uff08FSVNAQD\/P\uff09<\/li>\n          <li>\u7ebf\u63a7\u5668\uff1aPC-P1HVQA\uff08WiFi\u578b\uff09<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n\n    <div class=\"lm-plan-card-3 lm-plan-c\">\n      <span class=\"lm-rec-badge\">\ud83c\udf1f \u63a8\u8350<\/span>\n      <div class=\"lm-plan-card-header\">\n        <h3>\u65b9\u6848\u4e09 \u00b7 \u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/h3>\n        <p>\u8282\u80fd+\u8212\u9002+\u51c0\u5316 \u00b7 \u4e00\u6b65\u5230\u4f4d<\/p>\n      <\/div>\n      <div class=\"lm-plan-card-body\">\n        <div class=\"lm-plan-price\">122,527 <span>\u5143<\/span><\/div>\n        <h4>\u6838\u5fc3\u914d\u7f6e<\/h4>\n        <ul class=\"lm-plan-features\">\n          <li>\u4e00\u697c\uff1a\u8212\u4eab140\u7eaf\u6c1f\u7a7a\u8c03<\/li>\n          <li>\u4e8c\u697c+\u4e09\u697c\uff1a\u5c0a\u777f\u5168\u6548\u2161 200\u578b+\u6c34\u6a21\u5757<\/li>\n          <li>\u5185\u673a\uff1a\u4e09\u7ba1\u5236\u51c0\u5316\u578b\uff08FSVN2QB\/PC\uff09<\/li>\n          <li>\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236 \u00b7 \u4e0d\u964d\u6e29\u9664\u6e7f<\/li>\n          <li>\u7ebf\u63a7\u5668\uff1aPC-P1HPQA\uff08\u9ad8\u6e05\u5f69\u5c4f\uff09<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u8be6\u7ec6\u5bf9\u6bd4\u8868 -->\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u5bf9\u6bd4\u7ef4\u5ea6<\/th>\n          <th>\u65b9\u6848\u4e00\uff1a\u4f20\u7edf\u9505\u7089<\/th>\n          <th>\u65b9\u6848\u4e8c\uff1aVAM mini\u4e24\u8054\u4f9b<\/th>\n          <th>\u65b9\u6848\u4e09\uff1a\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u4e00\u53e5\u8bdd\u603b\u7ed3<\/strong><\/td>\n          <td>\u7cfb\u7edf\u7b80\u5355\uff0c\u70ed\u6c34\u4e00\u4f53<\/td>\n          <td>\u8282\u80fd\u7701\u7535\uff0c\u6027\u4ef7\u6bd4\u4e4b\u9009<\/td>\n          <td class=\"lm-gold\">\u8282\u80fd+\u8212\u9002+\u51c0\u5316\uff0c\u4e00\u6b65\u5230\u4f4d<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u4e00\u697c\u7cfb\u7edf<\/strong><\/td>\n          <td>\u8212\u4eab140\uff088\u6298\uff09<\/td>\n          <td>\u8212\u4eab140\uff088\u6298\uff09<\/td>\n          <td>\u8212\u4eab140\uff088\u6298\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u4e8c\u697c+\u4e09\u697c\u7cfb\u7edf<\/strong><\/td>\n          <td>\u8212\u4eab180\u7eaf\u6c1f\uff088\u6298\uff09<\/td>\n          <td>VAM mini 200\u578b+\u6c34\u6a21\u5757\uff088\u6298\uff09<\/td>\n          <td class=\"lm-gold\">\u5c0a\u777f\u5168\u6548\u2161 200\u578b+\u6c34\u6a21\u5757\uff088.5\u6298\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5730\u6696\u70ed\u6e90<\/strong><\/td>\n          <td>\u535a\u4e16G6100\u4e24\u7528\u7089<\/td>\n          <td>\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5<\/td>\n          <td>\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5730\u6696\u5355\u4ef7<\/strong><\/td>\n          <td class=\"lm-green\">120\u5143\/\u33a1\uff08\u4e0d\u542b\u9505\u7089\uff09<\/td>\n          <td>169\u5143\/\u33a1<\/td>\n          <td>169\u5143\/\u33a1<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n          <td class=\"lm-green\">\u9505\u7089\u4e00\u4f53\u4f9b\u5e94<\/td>\n          <td>\u9700\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n          <td>\u9700\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5185\u673a\u7c7b\u578b<\/strong><\/td>\n          <td>DC\u6807\u51c6\u578b\uff08FSNAQD\/P\uff09<\/td>\n          <td>DC\u6807\u51c6\u578b\uff08FSVNAQD\/P\uff09<\/td>\n          <td class=\"lm-gold\">\u4e09\u7ba1\u5236\u51c0\u5316\u578b\uff08FSVN2QB\/PC\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u7ebf\u63a7\u5668<\/strong><\/td>\n          <td>PC-P1HVQA\uff08\u666e\u901aWiFi\uff09<\/td>\n          <td>PC-P1HVQA\uff08\u666e\u901aWiFi\uff09<\/td>\n          <td class=\"lm-gold\">PC-P1HPQA\uff08\u9ad8\u6e05\u5f69\u5c4f\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u8d85\u914d\u7387<\/strong><\/td>\n          <td>110%<\/td>\n          <td>\u7ea6110%<\/td>\n          <td class=\"lm-green\">100%\uff08\u7406\u60f3\u72b6\u6001\uff09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5730\u6696\u8fd0\u884c\u8d39<\/strong><\/td>\n          <td>\u71c3\u6c14\u8d39\uff08\u57fa\u51c6\uff09<\/td>\n          <td class=\"lm-green\">\u770140%-60%<\/td>\n          <td class=\"lm-green\">\u770140%-60%<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u4f7f\u7528\u5bff\u547d<\/strong><\/td>\n          <td>10-12\u5e74<\/td>\n          <td>10-12\u5e74<\/td>\n          <td class=\"lm-green\">15\u5e74<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n<\/div>\n\n\n<!-- ============================================================\n     \u56db\u3001\u4e09\u5927\u65b9\u6848\u6700\u7ec8\u603b\u4ef7\u5bf9\u6bd4\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u56db<\/span>\n    <h2>\u4e09\u5927\u65b9\u6848\u6700\u7ec8\u603b\u4ef7\u5bf9\u6bd4<\/h2>\n  <\/div>\n\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u8d39\u7528\u9879<\/th>\n          <th class=\"lm-num\">\u65b9\u6848\u4e00\uff08\u4f20\u7edf\u9505\u7089\uff09<\/th>\n          <th class=\"lm-num\">\u65b9\u6848\u4e8c\uff08VAM mini\u4e24\u8054\u4f9b\uff09<\/th>\n          <th class=\"lm-num\">\u65b9\u6848\u4e09\uff08\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b\uff09<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>\u7cfb\u7edf\u4e00\uff08\u4e00\u697c\u00b7\u8212\u4eab\uff09<\/td>\n          <td class=\"lm-num\">24,190<\/td>\n          <td class=\"lm-num\">24,190<\/td>\n          <td class=\"lm-num\">24,190<\/td>\n        <\/tr>\n        <tr>\n          <td>\u7cfb\u7edf\u4e8c\uff08\u4e8c\u697c+\u4e09\u697c\uff09<\/td>\n          <td class=\"lm-num\">35,160<\/td>\n          <td class=\"lm-num\">61,225<\/td>\n          <td class=\"lm-num\">65,973<\/td>\n        <\/tr>\n        <tr>\n          <td>\u5730\u6696\u7cfb\u7edf<\/td>\n          <td class=\"lm-num lm-green\">32,430<\/td>\n          <td class=\"lm-num\">32,364<\/td>\n          <td class=\"lm-num\">32,364<\/td>\n        <\/tr>\n        <tr class=\"lm-total-row\">\n          <td><strong>\u5408\u8ba1<\/strong><\/td>\n          <td class=\"lm-num\" style=\"font-size:18px;\"><strong>91,780<\/strong><\/td>\n          <td class=\"lm-num\" style=\"font-size:18px;\"><strong>117,779<\/strong><\/td>\n          <td class=\"lm-num\" style=\"font-size:18px;\"><strong>122,527<\/strong><\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u4e0e\u65b9\u6848\u4e00\u603b\u4ef7\u5dee<\/strong><\/td>\n          <td class=\"lm-center lm-green\">\u57fa\u51c6<\/td>\n          <td class=\"lm-num lm-red\">+25,999<\/td>\n          <td class=\"lm-num lm-red\">+30,747<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u4e09\u5f20\u4ef7\u683c\u5361\u7247 -->\n  <div class=\"lm-price-compare-3\">\n    <div class=\"lm-price-card-3 lm-price-a\">\n      <div class=\"lm-price-card-label\">\u65b9\u6848\u4e00<\/div>\n      <div class=\"lm-price-card-name\">\u4f20\u7edf\u9505\u7089\u65b9\u6848<\/div>\n      <span class=\"lm-price-card-amount\">91,780<\/span>\n      <div style=\"font-size:13px;color:#6b7280;\">\u542b\u5168\u90e8\u8bbe\u5907+\u5b89\u88c5\u8d39<\/div>\n      <div class=\"lm-price-card-tag\">\u521d\u6295\u8d44\u6700\u4f4e<\/div>\n    <\/div>\n\n    <div class=\"lm-price-card-3 lm-price-b\">\n      <div class=\"lm-price-card-label\">\u65b9\u6848\u4e8c<\/div>\n      <div class=\"lm-price-card-name\">VAM mini\u4e24\u8054\u4f9b<\/div>\n      <span class=\"lm-price-card-amount\">117,779<\/span>\n      <div style=\"font-size:13px;color:#6b7280;\">\u542b\u5168\u90e8\u8bbe\u5907+\u5b89\u88c5\u8d39<\/div>\n      <div class=\"lm-price-card-tag\">\u8282\u80fd\u6027\u4ef7\u6bd4<\/div>\n    <\/div>\n\n    <div class=\"lm-price-card-3 lm-price-c\">\n      <div class=\"lm-price-card-label\">\u65b9\u6848\u4e09 \u00b7 \u63a8\u8350<\/div>\n      <div class=\"lm-price-card-name\">\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b<\/div>\n      <span class=\"lm-price-card-amount\">122,527<\/span>\n      <div style=\"font-size:13px;color:#6b7280;\">\u542b\u5168\u90e8\u8bbe\u5907+\u5b89\u88c5\u8d39<\/div>\n      <div class=\"lm-price-card-tag\">\u54c1\u8d28\u4e00\u6b65\u5230\u4f4d<\/div>\n    <\/div>\n  <\/div>\n\n  <div class=\"lm-info-box\">\n    <strong>\ud83d\udcb0 \u8fd0\u884c\u8d39\u8bf4\u660e\uff1a<\/strong>\u65b9\u6848\u4e00\u5730\u6696\u8fd0\u884c\u8d39\u4e3a\u71c3\u6c14\u8d39\uff1b\u65b9\u6848\u4e8c\/\u4e09\u4e3a\u7535\u8d39\uff08\u70ed\u6cf5\uff09\uff0c\u6bd4\u71c3\u6c14\u770140%-60%\uff0c\u7ea65-10\u5e74\u53ef\u6536\u56de\u5dee\u4ef7\u3002\u4ee5\u6210\u90fd\u7ea6191.5\u33a1\u4e3a\u4f8b\uff0c\u70ed\u6cf5\u5730\u6696\u5b63\u6708\u8d39\u7ea6700-900\u5143\u3002\n  <\/div>\n\n  <div class=\"lm-tip\">\n    <strong>\ud83d\udccc \u6ce8\u610f\uff1a<\/strong>\u4ee5\u4e0a\u4ef7\u683c\u5df2\u6b63\u786e\u5e94\u7528\u6298\u6263\u89c4\u5219\uff08\u8212\u4eab\/VAM mini 8\u6298\uff0c\u5c0a\u777f\u5168\u6548 8.5\u6298\uff09\uff0c\u5b89\u88c5\u8d39\u3001\u7ebf\u63a7\u5668\u3001\u6c34\u6a21\u5757\u5b89\u88c5\u8d39\u3001\u5730\u6696\u4e0d\u6253\u6298\u3002\u65b9\u6848\u4e8c\/\u4e09\u9700\u53e6\u914d\u751f\u6d3b\u70ed\u6c34\u5668\uff0c\u65b9\u6848\u4e00\u70ed\u6c34\u7531\u9505\u7089\u4e00\u4f53\u4f9b\u5e94\u3002\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u4e94\u3001\u4e09\u5927\u65b9\u6848\u4e00\u53e5\u8bdd\u9009\u578b\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u4e94<\/span>\n    <h2>\u4e09\u5927\u65b9\u6848\u4e00\u53e5\u8bdd\u9009\u578b<\/h2>\n  <\/div>\n\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u5982\u679c\u60a8\u662f\u8fd9\u6837\u7684\u5ba2\u6237<\/th>\n          <th>\u63a8\u8350\u65b9\u6848<\/th>\n          <th class=\"lm-num\">\u603b\u4ef7<\/th>\n          <th>\u6838\u5fc3\u539f\u56e0<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\"\u6211\u60f3\u8981\u6700\u4fbf\u5b9c\u7684\uff0c\u7cfb\u7edf\u8d8a\u7b80\u5355\u8d8a\u597d\"<\/strong><\/td>\n          <td class=\"lm-green\"><strong>\u2705 \u65b9\u6848\u4e00<\/strong><\/td>\n          <td class=\"lm-num lm-green\"><strong>91,780\u5143<\/strong><\/td>\n          <td>\u521d\u6295\u8d44\u6700\u4f4e\uff0c\u70ed\u6c34\u4e00\u4f53\uff0c\u5b89\u88c5\u7b80\u5355<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\"\u6211\u6ce8\u91cd\u957f\u671f\u8282\u80fd\uff0c\u613f\u610f\u591a\u4e00\u70b9\u521d\u6295\u8d44\"<\/strong><\/td>\n          <td><strong>\u65b9\u6848\u4e8c<\/strong><\/td>\n          <td class=\"lm-num\"><strong>117,779\u5143<\/strong><\/td>\n          <td>\u70ed\u6cf5\u5730\u6696\u770140%-60%\uff0c5-10\u5e74\u56de\u672c<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\"\u6211\u8981\u6700\u8212\u9002\u7684\u5c45\u4f4f\u4f53\u9a8c\uff0c\u4e00\u6b65\u5230\u4f4d\"<\/strong><\/td>\n          <td class=\"lm-gold\"><strong>\u65b9\u6848\u4e09<\/strong><\/td>\n          <td class=\"lm-num lm-gold\"><strong>122,527\u5143<\/strong><\/td>\n          <td>\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u3001\u51c0\u5316\u3001\u81ea\u6e05\u6d01\u300115\u5e74\u5bff\u547d<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u516d\u3001\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u516d<\/span>\n    <h2>\u4f53\u9a8c\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n  <\/div>\n\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u7ef4\u5ea6<\/th>\n          <th class=\"lm-center\">\u65b9\u6848\u4e00<\/th>\n          <th class=\"lm-center\">\u65b9\u6848\u4e8c<\/th>\n          <th class=\"lm-center\">\u65b9\u6848\u4e09<\/th>\n          <th>\u4f18\u52bf\u65b9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u51fa\u98ce\u8212\u9002\u5ea6<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u9759\u97f3\u6027<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td>\u6301\u5e73<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5065\u5eb7\u6307\u6570<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u9664\u6e7f\u80fd\u529b<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u667a\u80fd\u64cd\u4f5c<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5b89\u88c5\u7b80\u6d01\u5ea6<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e00<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u4e03\u3001\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u4e03<\/span>\n    <h2>\u8d39\u7528\u516d\u7ef4\u5ea6\u5bf9\u6bd4<\/h2>\n  <\/div>\n\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u7ef4\u5ea6<\/th>\n          <th class=\"lm-center\">\u65b9\u6848\u4e00<\/th>\n          <th class=\"lm-center\">\u65b9\u6848\u4e8c<\/th>\n          <th class=\"lm-center\">\u65b9\u6848\u4e09<\/th>\n          <th>\u4f18\u52bf\u65b9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u521d\u6295\u8d44<\/strong><\/td>\n          <td class=\"lm-num lm-green\"><strong>91,780<\/strong><\/td>\n          <td class=\"lm-num\">117,779<\/td>\n          <td class=\"lm-num\">122,527<\/td>\n          <td class=\"lm-green lm-winner\">\u65b9\u6848\u4e00<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u7cfb\u7edf\u80fd\u6548<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5b89\u88c5\u590d\u6742\u5ea6<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e00<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u7cfb\u7edf\u53ef\u9760\u6027<\/strong><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-center\"><span class=\"lm-stars\">\u2605\u2605\u2605\u2605\u2605<\/span><\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u5730\u6696\u8fd0\u884c\u8d39<\/strong><\/td>\n          <td>\u71c3\u6c14\u8d39\uff08\u57fa\u51c6\uff09<\/td>\n          <td class=\"lm-green\">\u770140%-60%<\/td>\n          <td class=\"lm-green\">\u770140%-60%<\/td>\n          <td class=\"lm-green lm-winner\">\u65b9\u6848\u4e8c\/\u4e09<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u751f\u6d3b\u70ed\u6c34<\/strong><\/td>\n          <td class=\"lm-green\"><strong>\u9505\u7089\u4e00\u4f53\u4f9b\u5e94<\/strong><\/td>\n          <td>\u9700\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n          <td>\u9700\u72ec\u7acb\u70ed\u6c34\u5668<\/td>\n          <td class=\"lm-green lm-winner\">\u65b9\u6848\u4e00<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u4f7f\u7528\u5bff\u547d<\/strong><\/td>\n          <td>10-12\u5e74<\/td>\n          <td>10-12\u5e74<\/td>\n          <td class=\"lm-green\">15\u5e74<\/td>\n          <td class=\"lm-winner\">\u65b9\u6848\u4e09<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-info-box\">\n    <strong>\ud83d\udcb0 \u957f\u671f\u8d39\u7528\u6d4b\u7b97\uff1a<\/strong>\u65b9\u6848\u4e8c\/\u4e09\u6bd4\u65b9\u6848\u4e00\u8d35\u7ea62.6-3.1\u4e07\uff0c\u4f46\u70ed\u6cf5\u5730\u6696\u6bcf\u5e74\u53ef\u8282\u7701\u71c3\u6c14\u8d39\u7ea640%-60%\u3002\u4ee5\u6210\u90fd\u51ac\u5b63\u71c3\u6c14\u5730\u6696\u6708\u8d392,000\u5143\u8ba1\uff0c\u6bcf\u5e74\u53ef\u8282\u7701\u7ea63,200-4,800\u5143\uff0c\u7ea65-10\u5e74\u53ef\u6536\u56de\u5dee\u4ef7\u3002\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u516b\u3001\u9009\u578b\u5efa\u8bae\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u516b<\/span>\n    <h2>\u9009\u578b\u5efa\u8bae<\/h2>\n  <\/div>\n\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u5982\u679c\u60a8\u66f4\u770b\u91cd<\/th>\n          <th>\u63a8\u8350\u65b9\u6848<\/th>\n          <th>\u6838\u5fc3\u7406\u7531<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>\u521d\u6295\u8d44\u6700\u4f4e\uff0c\u7cfb\u7edf\u6700\u7b80\u5355<\/strong><\/td>\n          <td class=\"lm-green\"><strong>\u2705 \u65b9\u6848\u4e00<\/strong><\/td>\n          <td>\u7ea69.2\u4e07\uff0c\u70ed\u6c34\u4e00\u4f53\uff0c\u65e0\u9700\u989d\u5916\u8bbe\u5907<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u8282\u80fd\u7701\u7535\uff0c\u8ffd\u6c42\u6027\u4ef7\u6bd4<\/strong><\/td>\n          <td><strong>\u65b9\u6848\u4e8c<\/strong><\/td>\n          <td>\u957f\u671f\u8fd0\u884c\u8d39\u4f4e\uff0c\u7ea611.8\u4e07\uff0c5-10\u5e74\u56de\u672c<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236<\/strong><\/td>\n          <td class=\"lm-gold\"><strong>\u65b9\u6848\u4e09<\/strong><\/td>\n          <td>\u4e09\u7ba1\u5236\u5185\u673a\uff0c\u9664\u6e7f\u4e0d\u964d\u6e29\uff0c\u884c\u4e1a\u72ec\u6709<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u7a7a\u6c14\u51c0\u5316<\/strong><\/td>\n          <td class=\"lm-gold\"><strong>\u65b9\u6848\u4e09<\/strong><\/td>\n          <td>PE+\u51c0\u5316\u6a21\u5757\u6807\u914d\uff0c6\u4eba\u5bb6\u5ead\u66f4\u5065\u5eb7<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u64cd\u63a7\u4f53\u9a8c<\/strong><\/td>\n          <td class=\"lm-gold\"><strong>\u65b9\u6848\u4e09<\/strong><\/td>\n          <td>\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668\uff0c\u64cd\u4f5c\u66f4\u76f4\u89c2<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>\u957f\u671f\u8212\u9002\u5ea6<\/strong><\/td>\n          <td class=\"lm-gold\"><strong>\u65b9\u6848\u4e09<\/strong><\/td>\n          <td>\u529f\u80fd\u6700\u5168\u9762\uff0c\u8d85\u914d\u7387100%\uff0c\u4f7f\u7528\u5bff\u547d15\u5e74<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- \u63a8\u8350\u6587\u6848 -->\n  <div class=\"lm-recommend-card\">\n    <h3>\ud83c\udf1f \u4f18\u9009\u63a8\u8350<\/h3>\n    <p><strong>\u65b9\u6848\u4e00\uff08\u4f20\u7edf\u9505\u7089\uff09\u521d\u6295\u8d44\u6700\u4f4e\uff0c\u4ec591,780\u5143<\/strong>\uff0c\u5730\u6696\u94fa\u8bbe120\u5143\/\u33a1 + \u535a\u4e16G6100\u9505\u7089\uff085,850\u5143\uff09+ \u5b89\u88c5\u8d39\uff08600\u5143\uff09+ \u4e8c\u6b21\u7cfb\u7edf\uff083,000\u5143\uff09\uff0c\u7cfb\u7edf\u7b80\u5355\uff0c\u751f\u6d3b\u70ed\u6c34\u4e00\u4f53\u4f9b\u5e94\uff0c\u9002\u5408\u9884\u7b97\u4f18\u5148\u7684\u5ba2\u6237\u3002<\/p>\n    <p style=\"margin-top:14px;\"><strong>\u65b9\u6848\u4e09\uff08\u5c0a\u777f\u5168\u6548\u4e24\u8054\u4f9b\uff09\u603b\u4ef7\u7ea612.25\u4e07<\/strong>\uff0c\u6bd4\u65b9\u6848\u4e00\u8d35\u7ea63.1\u4e07\uff0c\u6bd4\u65b9\u6848\u4e8c\u8d35\u7ea60.5\u4e07\uff0c\u6362\u6765\uff1a<\/p>\n    <p style=\"margin-top:8px;\">\n      <span class=\"lm-tag gold\">\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236<\/span>\n      <span class=\"lm-tag gold\">\u4e0d\u964d\u6e29\u9664\u6e7f<\/span>\n      <span class=\"lm-tag gold\">PE+\u51c0\u5316\u6807\u914d<\/span>\n      <span class=\"lm-tag gold\">\u81ea\u6e05\u6d01+\u9ad8\u6e29\u6d88\u6bd2<\/span>\n      <span class=\"lm-tag gold\">\u9ad8\u6e05\u5f69\u5c4f\u7ebf\u63a7\u5668<\/span>\n      <span class=\"lm-tag gold\">\u8d85\u914d\u7387100%<\/span>\n      <span class=\"lm-tag gold\">\u4f7f\u7528\u5bff\u547d15\u5e74<\/span>\n    <\/p>\n    <p style=\"margin-top:14px;\">\u70ed\u6cf5\u5730\u6696\u8fd0\u884c\u8d39\u6bd4\u71c3\u6c14\u5730\u6696<strong>\u770140%-60%<\/strong>\uff0c6\u4eba\u5bb6\u5ead\u957f\u671f\u5c45\u4f4f\uff0c\u5e74\u8282\u7701\u8d39\u7528\u66f4\u663e\u8457\u3002\u5982\u679c\u60a8\u5bf9\u751f\u6d3b\u54c1\u8d28\u6709\u8981\u6c42\uff0c\u8fd9\u662f\u6700\u4f18\u9009\u62e9\u3002<\/p>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u4e5d\u3001\u8f85\u6750\u6e05\u5355\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u4e5d<\/span>\n    <h2>\u9644\uff1a\u8f85\u6750\u6e05\u5355<\/h2>\n  <\/div>\n\n  <div class=\"lm-sub-title\">\u9644\u8868A\uff1a\u7a7a\u8c03\u8f85\u6750\u6e05\u5355\uff08\u4e09\u65b9\u6848\u901a\u7528\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th class=\"lm-center\">\u5e8f\u53f7<\/th>\n          <th>\u8f85\u6750\u540d\u79f0<\/th>\n          <th>\u89c4\u683c<\/th>\n          <th>\u8bf4\u660e<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"lm-center\">1<\/td><td>\u51b7\u5a92\u94dc\u7ba1<\/td><td>\u03c66.35~\u03c619.05<\/td><td>\u542b\u4fdd\u6e29\u7ba1<\/td><\/tr>\n        <tr><td class=\"lm-center\">2<\/td><td>\u51b7\u51dd\u6c34\u7ba1<\/td><td>PVC-U<\/td><td>\u542b\u4fdd\u6e29<\/td><\/tr>\n        <tr><td class=\"lm-center\">3<\/td><td>\u5206\u6b67\u7ba1<\/td><td>\u65e5\u7acb\u539f\u5382<\/td><td>E-52SN\/102SN\u7b49<\/td><\/tr>\n        <tr><td class=\"lm-center\">4<\/td><td>\u51b7\u5a92<\/td><td>R410A<\/td><td>\u8865\u5145\u704c\u6ce8<\/td><\/tr>\n        <tr><td class=\"lm-center\">5<\/td><td>\u4fe1\u53f7\u7ebf<\/td><td>1.0mm\u00b2\u5c4f\u853d\u7ebf<\/td><td>\u5185\u673a\u901a\u8baf<\/td><\/tr>\n        <tr><td class=\"lm-center\">6<\/td><td>\u5916\u673a\u652f\u67b6\/\u51cf\u9707\u57ab<\/td><td>\u5b9a\u5236<\/td><td>\u5916\u673a\u5b89\u88c5<\/td><\/tr>\n        <tr><td class=\"lm-center\">7<\/td><td>\u4fdd\u6e29\u80f6\u5e26\/\u624e\u5e26<\/td><td>\u6807\u51c6<\/td><td>\u7ba1\u8def\u5305\u624e<\/td><\/tr>\n        <tr><td class=\"lm-center\">8<\/td><td>\u6c2e\u6c14<\/td><td>\u5de5\u4e1a\u7ea7<\/td><td>\u4fdd\u538b\/\u5439\u626b<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <div class=\"lm-note\">\ud83d\udccc \u8f85\u6750\u8d39\u7528\u5df2\u5305\u542b\u5728\u5b89\u88c5\u8d39\u4e2d\uff0c\u4e0d\u5355\u72ec\u8ba1\u4ef7\u3002<\/div>\n\n  <div class=\"lm-sub-title\">\u9644\u8868B\uff1a\u5730\u6696\u8f85\u6750\u6e05\u5355\uff08\u5168\u5c4b\u7edf\u4e00\uff09<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th class=\"lm-center\">\u5e8f\u53f7<\/th>\n          <th>\u8f85\u6750\u540d\u79f0<\/th>\n          <th>\u54c1\u724c\/\u89c4\u683c<\/th>\n          <th>\u8bf4\u660e<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"lm-center\">1<\/td><td>\u5730\u6696\u4e3b\u7ba1<\/td><td>\u4f1f\u661fPPR<\/td><td>\u542b\u4fdd\u6e29<\/td><\/tr>\n        <tr><td class=\"lm-center\">2<\/td><td>\u5730\u6696\u76d8\u7ba1<\/td><td>\u4f1f\u661fPE-RT<\/td><td>\u03c620\u00d72.0<\/td><\/tr>\n        <tr><td class=\"lm-center\">3<\/td><td>\u5206\u96c6\u6c34\u5668<\/td><td>\u4f1f\u661f\/\u66fc\u745e\u5fb7<\/td><td>\u542b\u9600\u95e8\u3001\u6d41\u91cf\u8ba1<\/td><\/tr>\n        <tr><td class=\"lm-center\">4<\/td><td>\u4fdd\u6e29\u677f<\/td><td>XPS\u6324\u5851\u677f<\/td><td>2cm\u539a \u00d7 191.5\u33a1<\/td><\/tr>\n        <tr><td class=\"lm-center\">5<\/td><td>\u53cd\u5c04\u819c<\/td><td>\u94dd\u7b94<\/td><td>191.5\u33a1<\/td><\/tr>\n        <tr><td class=\"lm-center\">6<\/td><td>\u94a2\u4e1d\u7f51<\/td><td>\u03c63\u00d7100\u00d7100<\/td><td>191.5\u33a1 \u52a0\u56fa\/\u627e\u5e73\u5c42<\/td><\/tr>\n        <tr><td class=\"lm-center\">7<\/td><td>\u8fb9\u754c\u4fdd\u6e29\u6761<\/td><td>EPE<\/td><td>\u5899\u4f53\u56db\u5468<\/td><\/tr>\n        <tr><td class=\"lm-center\">8<\/td><td>\u6e29\u63a7\u5668+\u7535\u70ed\u6267\u884c\u5668<\/td><td>\u66fc\u745e\u5fb7<\/td><td>\u5206\u533a\u63a7\u5236<\/td><\/tr>\n        <tr><td class=\"lm-center\">9<\/td><td>\u8054\u52a8\u63a7\u5236\u5668<\/td><td>\u66fc\u745e\u5fb7<\/td><td>\u4e3b\u673a\u8054\u52a8<\/td><\/tr>\n        <tr><td class=\"lm-center\">10<\/td><td>\u56de\u586b\u627e\u5e73<\/td><td>C20\u7ec6\u77f3\u6df7\u51dd\u571f<\/td><td>\u539a\u5ea63-5cm<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <div class=\"lm-tip\">\n    <strong>\ud83d\udccc \u6ce8\u610f\uff1a<\/strong>\u65b9\u6848\u4e8c\/\u4e09\u5730\u6696\u5355\u4ef7169\u5143\/\u33a1\u5df2\u5305\u542b\u4ee5\u4e0a\u6240\u6709\u8f85\u6750\u53ca\u5b89\u88c5\u3001\u56de\u586b\u8d39\u7528\uff1b\u65b9\u6848\u4e00\u5730\u6696120\u5143\/\u33a1\uff08\u4e0d\u542b\u9505\u7089\uff09\u4e3a\u94fa\u8bbe\u5355\u4ef7\uff0c\u7efc\u5408\u62a5\u4ef7 = \u9505\u7089\u53ca\u9644\u4ef6 + \u4ee5\u4e0a\u8f85\u6750\u5168\u5957\u3002\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u5341\u3001\u670d\u52a1\u627f\u8bfa\u4e0e\u4fdd\u969c\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u5341<\/span>\n    <h2>\u670d\u52a1\u627f\u8bfa\u4e0e\u4fdd\u969c<\/h2>\n  <\/div>\n\n  <div class=\"lm-service-grid\">\n    <div class=\"lm-service-item\">\n      <span class=\"lm-service-icon\">\ud83d\udcd0<\/span>\n      <h4>\u5b89\u88c5\u524d \u00b7 \u73b0\u573a\u52d8\u6d4b<\/h4>\n      <p>\u4e13\u4e1a\u5de5\u7a0b\u5e08\u4e0a\u95e8\u52d8\u6d4b\uff0c\u5b9a\u5236\u8bbe\u8ba1\u51fa\u56fe\uff0c\u6750\u6599\u6838\u5bf9\u786e\u8ba4<\/p>\n    <\/div>\n    <div class=\"lm-service-item\">\n      <span class=\"lm-service-icon\">\ud83d\udd27<\/span>\n      <h4>\u65bd\u5de5\u4e2d \u00b7 \u7cbe\u5de5\u6807\u51c6<\/h4>\n      <p>\u6c2e\u6c14\u4fdd\u62a4\u710a\u3001\u9690\u853d\u5de5\u7a0b\u9a8c\u6536\u3001\u4fdd\u538b\u6d4b\u8bd5\uff0c\u5168\u7a0b\u53ef\u89c6\u5316<\/p>\n    <\/div>\n    <div class=\"lm-service-item\">\n      <span class=\"lm-service-icon\">\u2705<\/span>\n      <h4>\u65bd\u5de5\u540e \u00b7 \u4e25\u683c\u68c0\u6d4b<\/h4>\n      <p>\u62bd\u771f\u7a7a\uff082\u5c0f\u65f6+\uff09\u3001\u8ffd\u52a0\u51b7\u5a92\u3001\u8fd0\u884c\u6d4b\u8bd5\uff0c\u786e\u4fdd\u8fbe\u6807<\/p>\n    <\/div>\n    <div class=\"lm-service-item\">\n      <span class=\"lm-service-icon\">\ud83d\udcd6<\/span>\n      <h4>\u4ea4\u4ed8 \u00b7 \u4f7f\u7528\u6559\u5b66<\/h4>\n      <p>\u63a7\u5236\u5668\u4f7f\u7528\u6559\u5b66\u3001APP\u64cd\u4f5c\u6307\u5bfc\u3001\u6ee4\u7f51\u6e05\u6d17\u6559\u5b66<\/p>\n    <\/div>\n    <div class=\"lm-service-item\">\n      <span class=\"lm-service-icon\">\ud83d\udee1\ufe0f<\/span>\n      <h4>\u8d28\u4fdd \u00b7 \u884c\u4e1a\u9886\u5148<\/h4>\n      <p>\u6574\u673a5\u5e74\u8d77\uff0c\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6\uff0c\u8ba9\u60a8\u65e0\u540e\u987e\u4e4b\u5fe7<\/p>\n    <\/div>\n    <div class=\"lm-service-item\">\n      <span class=\"lm-service-icon\">\u267e\ufe0f<\/span>\n      <h4>\u7ec8\u8eab \u00b7 \u6301\u7eed\u670d\u52a1<\/h4>\n      <p>\u4e13\u5c5e\u9879\u76ee\u6863\u6848\u8986\u76d6\u5168\u6d41\u7a0b\uff0c\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9<\/p>\n    <\/div>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u5341\u4e00\u3001\u4f1a\u5458\u6743\u76ca\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u5341\u4e00<\/span>\n    <h2>\u4f1a\u5458\u6743\u76ca<\/h2>\n  <\/div>\n\n  <div class=\"lm-member-box\">\n    <h3>\ud83c\udf81 \u9f99\u8109\u6696\u901a VIP \u4f1a\u5458\u6743\u76ca\uff08199\u5143\/\u5e74\uff09<\/h3>\n    <p style=\"font-size:13px;opacity:0.85;margin:0 0 16px;\">\u6d3b\u52a8\u671f\u95f4\uff0c\u9996\u5e74\u4f1a\u5458\u8d39\u53ef\u7528\u6696\u901a\u91d1\u989d\u62b5\u6263\uff0c\u76f8\u5f53\u4e8e<strong style=\"color:#fcd34d;\">\u514d\u8d39\u5165\u4f1a<\/strong>\uff01<\/p>\n\n    <div class=\"lm-member-grid\">\n      <div class=\"lm-member-item\">\n        <span class=\"lm-member-label\">\u6574\u673a\u8d28\u4fdd<\/span>\n        <div class=\"lm-member-value\">10\u5e74<\/div>\n        <div style=\"font-size:12px;opacity:0.7;margin-top:4px;\">\u975e\u4f1a\u5458\u4ec55\u5e74<\/div>\n      <\/div>\n      <div class=\"lm-member-item\">\n        <span class=\"lm-member-label\">\u4e0a\u95e8\u68c0\u6d4b<\/span>\n        <div class=\"lm-member-value\">\u514d\u8d39<\/div>\n        <div style=\"font-size:12px;opacity:0.7;margin-top:4px;\">\u975e\u4f1a\u5458200\u5143\/\u6b21<\/div>\n      <\/div>\n      <div class=\"lm-member-item\">\n        <span class=\"lm-member-label\">\u7ef4\u4fee\u670d\u52a1\u8d39<\/span>\n        <div class=\"lm-member-value\">8\u6298<\/div>\n        <div style=\"font-size:12px;opacity:0.7;margin-top:4px;\">\u542b\u914d\u4ef6\u66f4\u6362<\/div>\n      <\/div>\n      <div class=\"lm-member-item\">\n        <span class=\"lm-member-label\">\u4fdd\u517b\u670d\u52a1<\/span>\n        <div class=\"lm-member-value\">5\u6298<\/div>\n        <div style=\"font-size:12px;opacity:0.7;margin-top:4px;\">\u6df1\u5ea6\u4fdd\u517b\u4f18\u60e0<\/div>\n      <\/div>\n      <div class=\"lm-member-item\">\n        <span class=\"lm-member-label\">\u7d27\u6025\u54cd\u5e94<\/span>\n        <div class=\"lm-member-value\">24\u5c0f\u65f6<\/div>\n        <div style=\"font-size:12px;opacity:0.7;margin-top:4px;\">\u975e\u4f1a\u545848\u5c0f\u65f6<\/div>\n      <\/div>\n      <div class=\"lm-member-item\">\n        <span class=\"lm-member-label\">\u6696\u901a\u91d1\u7b7e\u7ea6\u8d60<\/span>\n        <div class=\"lm-member-value\">1,000\u5143<\/div>\n        <div style=\"font-size:12px;opacity:0.7;margin-top:4px;\">\u53ef\u62b5\u8bbe\u5907\u6b3e\/\u5b89\u88c5\u8d39<\/div>\n      <\/div>\n    <\/div>\n\n    <div style=\"margin-top:20px;padding-top:16px;border-top:1px solid rgba(255,255,255,0.15);\">\n      <p style=\"font-size:13px;opacity:0.8;margin:0;text-align:center;\">\n        \ud83d\udccc \u9996\u5e74\u4f1a\u5458\u514d\u8d39\u8d60\u9001\uff0c\u7b2c\u4e8c\u5e74\u8d77\u53ef\u7eed\u8d39\uff08199\u5143\/\u5e74\uff09&nbsp;|&nbsp;\n        \u65e5\u7acb\u5382\u8865\uff1a\u8212\u4eab500\u5143\/\u6237 &nbsp;|&nbsp; \u5c0a\u777f\u5168\u65482,000\u5143\/\u6237\n      <\/p>\n    <\/div>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u5341\u4e8c\u3001AI\u9a8c\u8bc1\u4e0e\u9644\u6ce8\u6761\u6b3e\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u5341\u4e8c<\/span>\n    <h2>AI\u9a8c\u8bc1\u6307\u5f15\u4e0e\u9644\u6ce8\u6761\u6b3e<\/h2>\n  <\/div>\n\n  <div class=\"lm-sub-title\">AI\u9a8c\u8bc1\u6307\u5f15<\/div>\n  <div class=\"lm-info-box\">\n    \u5c0f\u5468\u8001\u5e08\uff0c\u60a8\u53ef\u4ee5\u5c06\u4ee5\u4e0b\u95ee\u9898\u590d\u5236\u53d1\u7ed9\u8c46\u5305\/\u5143\u5b9d\/DeepSeek \u8fdb\u884c\u72ec\u7acb\u9a8c\u8bc1\uff1a<br><br>\n    1. \"\u65e5\u7acbVAM mini\u4e24\u8054\u4f9b\u548c\u5c0a\u777f\u5168\u6548\u2161\u4e24\u8054\u4f9b\u6709\u4ec0\u4e48\u533a\u522b\uff1f\"<br>\n    2. \"\u535a\u4e16\u9505\u7089\u5730\u6696\u548c\u5929\u6c1f\u5730\u6c34\u70ed\u6cf5\u5730\u6696\uff0c20\u5e74\u603b\u6295\u5165\u54ea\u4e2a\u66f4\u4f4e\uff1f\"<br>\n    3. \"\u4e09\u7ba1\u5236\u5185\u673a\u7684\u6e29\u6e7f\u72ec\u7acb\u63a7\u5236\u662f\u4ec0\u4e48\u610f\u601d\uff1f\u6709\u4ec0\u4e48\u597d\u5904\uff1f\"<br>\n    4. \"6\u4eba\u5bb6\u5ead\u7528\u70ed\u6cf5\u5730\u6696\u6bcf\u6708\u5927\u6982\u82b1\u591a\u5c11\u7535\u8d39\uff1f\"\n  <\/div>\n\n  <div class=\"lm-sub-title\">\u9644\u6ce8\u6761\u6b3e<\/div>\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th class=\"lm-center\">\u5e8f\u53f7<\/th>\n          <th>\u6e29\u99a8\u63d0\u793a<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td class=\"lm-center\"><strong>1<\/strong><\/td>\n          <td>\u672c\u65b9\u6848\u4e3a<strong>\u4e00\u697c\u8212\u4eab\u7eaf\u6c1f\u7a7a\u8c03 + \u4e8c\u697c+\u4e09\u697c\u72ec\u7acb\u7cfb\u7edf<\/strong>\uff0c\u5206\u533a\u72ec\u7acb\u63a7\u5236<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong>2<\/strong><\/td>\n          <td><strong>\u65b9\u6848\u4e00\u5730\u6696\uff1a120\u5143\/\u33a1 \u00d7 191.5\u33a1 = 22,980\u5143\uff08\u94fa\u8bbe\u8d39\uff09\uff0c\u7efc\u5408\u62a5\u4ef7 = \u535a\u4e16G6100\u4e24\u7528\u7089\uff085,850\u5143\uff09+ \u9505\u7089\u5b89\u88c5\u8d39\uff08600\u5143\uff09+ \u4e8c\u6b21\u7cfb\u7edf\uff083,000\u5143\uff09+ \u5168\u5c4b\u5730\u6696\u94fa\u8bbe\uff0822,980\u5143\uff09= \u5730\u6696\u5c0f\u8ba132,430\u5143<\/strong><\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong>3<\/strong><\/td>\n          <td>\u65b9\u6848\u4e8c\/\u4e09\u5730\u6696\u5355\u4ef7169\u5143\/\u33a1\uff0c\u9762\u79ef\u7ea6191.5\u33a1\uff0c\u603b\u4ef732,364\u5143<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong>4<\/strong><\/td>\n          <td>\u5df2\u6309\u6298\u6263\u89c4\u5219\u8ba1\u7b97\uff1a\u8212\u4eab\/VAM mini 8\u6298\uff0c\u5c0a\u777f\u5168\u6548 8.5\u6298\uff0c\u5b89\u88c5\u8d39\u3001\u7ebf\u63a7\u5668\u3001\u6c34\u6a21\u5757\u5b89\u88c5\u8d39\u3001\u5730\u6696\u4e0d\u6253\u6298<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong>5<\/strong><\/td>\n          <td>\u65b9\u6848\u4e8c\/\u4e09\u9700\u72ec\u7acb\u914d\u7f6e\u751f\u6d3b\u70ed\u6c34\u5668\uff08\u63a8\u835020L\u71c3\u6c14\u70ed\u6c34\u5668\uff0c\u7ea63,000-5,000\u5143\uff09\uff0c\u65b9\u6848\u4e00\u70ed\u6c34\u7531\u9505\u7089\u4e00\u4f53\u4f9b\u5e94<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong>6<\/strong><\/td>\n          <td>\u65b9\u6848\u4e09\u5185\u673a\u5b89\u88c5\u8d39\u63091,900\u5143\/\u53f0\u6267\u884c<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong>7<\/strong><\/td>\n          <td>\u672c\u62a5\u4ef7\u6709\u6548\u671f\u4e3a15\u5929\uff08\u81f32026\u5e746\u670825\u65e5\uff09<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     \u5341\u4e09\u3001\u4e0b\u4e00\u6b65\u884c\u52a8\n     ============================================================ -->\n<div class=\"lm-section\">\n  <div class=\"lm-section-title\">\n    <span class=\"lm-section-num\">\u5341\u4e09<\/span>\n    <h2>\u4e0b\u4e00\u6b65\u884c\u52a8<\/h2>\n  <\/div>\n\n  <div class=\"lm-table-wrap\">\n    <table class=\"lm-table\">\n      <thead>\n        <tr>\n          <th>\u4f18\u5148\u7ea7<\/th>\n          <th>\u52a8\u4f5c<\/th>\n          <th>\u8d1f\u8d23\u4eba<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td class=\"lm-center\"><strong style=\"color:#e74c3c;\">P0<\/strong><\/td>\n          <td>\u5728\u4e09\u79cd\u65b9\u6848\u4e2d\u505a\u51fa\u6700\u7ec8\u9009\u62e9<\/td>\n          <td>\u5c0f\u5468\u8001\u5e08<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong style=\"color:#f39c12;\">P1<\/strong><\/td>\n          <td>\u9009\u5b9a\u65b9\u6848\u540e\uff0c\u5efa\u8bae\u52a0\u5165\u9f99\u8109\u6696\u901aVIP\u4f1a\u5458\uff08\u4eab\u8bbe\u5907\u6298\u6263\u7b49\u6743\u76ca\uff09<\/td>\n          <td>\u53cc\u65b9<\/td>\n        <\/tr>\n        <tr>\n          <td class=\"lm-center\"><strong style=\"color:#f39c12;\">P2<\/strong><\/td>\n          <td>\u7b7e\u8ba2\u6b63\u5f0f\u5408\u540c\uff0c\u9501\u5b9a\u4f18\u60e0\uff0c\u5b89\u6392\u65bd\u5de5\u6392\u671f<\/td>\n          <td>\u53cc\u65b9<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <div class=\"lm-tip\" style=\"text-align:center;\">\n    \ud83c\udfe1 <strong>\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002<\/strong>\n  <\/div>\n<\/div>\n\n\n<!-- ============================================================\n     Footer\n     ============================================================ -->\n<div class=\"lm-footer\">\n  <h3>\ud83d\udcde \u65b9\u6848\u987e\u95ee\uff1a\u9f99\u8109\u6696\u901a\u00b7\u9ec4\u52c7 &nbsp;|&nbsp; \u9f99\u8109\u6696\u901a\u00b7\u59cb\u4e8e2004<\/h3>\n\n  <div class=\"lm-footer-prices\">\n    <span>\u65b9\u6848\u4e00\uff1a91,780\u5143<\/span>\n    <span>\u65b9\u6848\u4e8c\uff1a117,779\u5143<\/span>\n    <span>\u65b9\u6848\u4e09\uff1a122,527\u5143<\/span>\n  <\/div>\n\n  <p style=\"font-size:14px;opacity:0.85;\">\n    \u4e13\u6ce8\u5bb6\u5ead\u8212\u9002\u8282\u80fd\u7cfb\u7edf22\u5e74 &nbsp;|&nbsp; \u6210\u90fd2\u4e07+\u5bb6\u5ead\u4fe1\u8d56\n  <\/p>\n\n  <div class=\"lm-footer-tagline\">\n    \"\u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb\u3002\"<br>\n    \u9f99\u8109\u6696\u901a\u4e3a\u6bcf\u4e00\u4f4d\u7b7e\u7ea6\u7528\u6237\u5efa\u7acb\u4e13\u5c5e\u9879\u76ee\u6863\u6848\uff0c\u8986\u76d6\u52d8\u6d4b\u3001\u8bbe\u8ba1\u3001\u65bd\u5de5\u3001\u4ea4\u4ed8\u5168\u6d41\u7a0b<br>\n    <span style=\"margin-top:8px;display:block;opacity:0.4;\">longmai-nt.com<\/span>\n  <\/div>\n<\/div>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a  [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2640","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2640\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2640\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-14T05:18:38+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2640\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2640\",\"name\":\"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-10T06:56:43+00:00\",\"dateModified\":\"2026-06-14T05:18:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2640#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2640\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2640#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2640","og_locale":"zh_CN","og_type":"article","og_title":"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848 - \u9f99\u8109\u6696\u901a","og_description":"LONGMAI HVAC \u00b7 \u9f99\u8109\u6696\u901a [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2640","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-14T05:18:38+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2640","url":"https:\/\/longmai-nt.com\/?page_id=2640","name":"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-10T06:56:43+00:00","dateModified":"2026-06-14T05:18:38+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2640#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2640"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2640#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u5c0f\u5468\u8001\u5e08 \u00b7 \u9f99\u6e56\u4e09\u5343\u96c6\u5b8c\u6574\u7248\u5bf9\u6bd4\u62a5\u4ef7\u65b9\u6848"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2640"}],"version-history":[{"count":4,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2640\/revisions"}],"predecessor-version":[{"id":3227,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2640\/revisions\/3227"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}