{"id":2653,"date":"2026-06-09T12:59:37","date_gmt":"2026-06-09T04:59:37","guid":{"rendered":"https:\/\/longmai-nt.com\/?page_id=2653"},"modified":"2026-06-13T16:24:32","modified_gmt":"2026-06-13T08:24:32","slug":"%e9%9f%a6%e5%a5%b3%e5%a3%ab%e5%a4%a7%e5%b9%b3%e5%b1%82","status":"publish","type":"page","link":"https:\/\/longmai-nt.com\/?page_id=2653","title":{"rendered":"\u97e6\u5973\u58eb\u5927\u5e73\u5c42"},"content":{"rendered":"\n\n<style>\n  * { margin: 0; padding: 0; box-sizing: border-box; }\n  body {\n    font-family: 'PingFang SC', 'Microsoft YaHei', -apple-system, BlinkMacSystemFont, sans-serif;\n    font-size: 14px;\n    color: #1a1a1a;\n    background: #f7f5f0;\n    line-height: 1.7;\n  }\n  a { color: #185FA5; text-decoration: none; }\n  a:hover { text-decoration: underline; }\n\n  \/* \u2500\u2500\u2500 Print \u2500\u2500\u2500 *\/\n  @media print {\n    body { background: #fff; }\n    .no-print { display: none !important; }\n    .page-break { page-break-before: always; }\n    .section { page-break-inside: avoid; }\n  }\n\n  \/* \u2500\u2500\u2500 Layout \u2500\u2500\u2500 *\/\n  .wrapper { max-width: 900px; margin: 0 auto; padding: 32px 20px 64px; }\n\n  \/* \u2500\u2500\u2500 Cover \u2500\u2500\u2500 *\/\n  .cover {\n    background: #1a2e4a;\n    color: #fff;\n    border-radius: 16px;\n    padding: 48px 48px 40px;\n    margin-bottom: 32px;\n    position: relative;\n    overflow: hidden;\n  }\n  .cover::before {\n    content: '';\n    position: absolute;\n    top: -60px; right: -60px;\n    width: 220px; height: 220px;\n    border-radius: 50%;\n    background: rgba(255,255,255,0.05);\n  }\n  .cover::after {\n    content: '';\n    position: absolute;\n    bottom: -40px; left: 40px;\n    width: 140px; height: 140px;\n    border-radius: 50%;\n    background: rgba(255,255,255,0.04);\n  }\n  .cover-tag {\n    display: inline-block;\n    font-size: 11px;\n    letter-spacing: 0.08em;\n    color: #a8c4e0;\n    border: 1px solid rgba(168,196,224,0.4);\n    border-radius: 4px;\n    padding: 3px 10px;\n    margin-bottom: 18px;\n    text-transform: uppercase;\n  }\n  .cover h1 { font-size: 26px; font-weight: 600; line-height: 1.4; margin-bottom: 8px; }\n  .cover-sub { font-size: 15px; color: #a8c4e0; margin-bottom: 28px; }\n  .cover-meta {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(160px, 1fr));\n    gap: 16px;\n    border-top: 1px solid rgba(255,255,255,0.12);\n    padding-top: 24px;\n    margin-top: 8px;\n  }\n  .cover-meta-item label {\n    display: block; font-size: 11px; color: #7ea8c8; letter-spacing: 0.06em; margin-bottom: 4px;\n  }\n  .cover-meta-item span { font-size: 14px; font-weight: 500; }\n\n  \/* \u2500\u2500\u2500 Section \u2500\u2500\u2500 *\/\n  .section {\n    background: #fff;\n    border-radius: 12px;\n    border: 0.5px solid #e8e5df;\n    padding: 28px 32px;\n    margin-bottom: 20px;\n  }\n  .section-title {\n    font-size: 16px; font-weight: 600; color: #1a2e4a;\n    padding-bottom: 14px;\n    border-bottom: 2px solid #e8e5df;\n    margin-bottom: 20px;\n    display: flex; align-items: center; gap: 10px;\n  }\n  .section-title .num {\n    width: 28px; height: 28px; border-radius: 50%;\n    background: #1a2e4a; color: #fff;\n    font-size: 13px; font-weight: 600;\n    display: flex; align-items: center; justify-content: center;\n    flex-shrink: 0;\n  }\n  .section-sub {\n    font-size: 13px; font-weight: 600; color: #1a2e4a;\n    margin: 18px 0 12px;\n  }\n\n  \/* \u2500\u2500\u2500 Table \u2500\u2500\u2500 *\/\n  .tbl-wrap { overflow-x: auto; margin-bottom: 12px; }\n  table { width: 100%; border-collapse: collapse; font-size: 13px; }\n  thead tr { background: #1a2e4a; color: #fff; }\n  thead th { padding: 9px 12px; text-align: left; font-weight: 500; white-space: nowrap; }\n  tbody tr { border-bottom: 0.5px solid #e8e5df; }\n  tbody tr:last-child { border-bottom: none; }\n  tbody tr:nth-child(even) { background: #fafaf8; }\n  tbody td { padding: 9px 12px; vertical-align: top; }\n  .td-mute { color: #888; font-size: 12px; }\n  .td-bold { font-weight: 600; }\n  .td-right { text-align: right; }\n  .td-center { text-align: center; }\n  .td-sum { background: #f0f4f8 !important; font-weight: 600; }\n\n  \/* \u2500\u2500\u2500 Compare cards \u2500\u2500\u2500 *\/\n  .compare-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(240px, 1fr));\n    gap: 16px;\n    margin-bottom: 16px;\n  }\n  .compare-card {\n    border-radius: 10px;\n    border: 1.5px solid #e8e5df;\n    padding: 20px;\n  }\n  .compare-card.featured {\n    border-color: #185FA5;\n    position: relative;\n  }\n  .compare-card.featured::before {\n    content: '\u6027\u4ef7\u6bd4\u4f18\u5148';\n    position: absolute; top: -11px; left: 50%; transform: translateX(-50%);\n    background: #185FA5; color: #fff;\n    font-size: 11px; padding: 2px 10px; border-radius: 20px;\n    white-space: nowrap;\n  }\n  .compare-card h3 { font-size: 15px; font-weight: 600; margin-bottom: 4px; color: #1a2e4a; }\n  .compare-card .brand-model { font-size: 12px; color: #888; margin-bottom: 14px; }\n  .compare-row { display: flex; justify-content: space-between; font-size: 13px; padding: 5px 0; border-bottom: 0.5px solid #f0ede7; }\n  .compare-row:last-child { border-bottom: none; }\n  .compare-row label { color: #666; }\n  .compare-row span { font-weight: 500; color: #1a1a1a; }\n\n  \/* \u2500\u2500\u2500 Price summary \u2500\u2500\u2500 *\/\n  .price-box {\n    background: #f0f4f8;\n    border-radius: 10px;\n    padding: 20px 24px;\n    margin: 16px 0;\n  }\n  .price-box-row {\n    display: flex; justify-content: space-between; align-items: baseline;\n    font-size: 14px; padding: 6px 0;\n    border-bottom: 0.5px solid #dde4ed;\n  }\n  .price-box-row:last-child { border-bottom: none; }\n  .price-box-total {\n    display: flex; justify-content: space-between; align-items: baseline;\n    margin-top: 10px; padding-top: 10px;\n    border-top: 2px solid #1a2e4a;\n  }\n  .price-box-total .label { font-size: 15px; font-weight: 600; color: #1a2e4a; }\n  .price-box-total .amount { font-size: 22px; font-weight: 700; color: #1a2e4a; }\n\n  \/* \u2500\u2500\u2500 Highlight row \u2500\u2500\u2500 *\/\n  .hl-row {\n    background: #e8f0f8;\n    border-radius: 8px;\n    padding: 14px 18px;\n    font-size: 13px;\n    margin: 12px 0;\n    border-left: 3px solid #185FA5;\n  }\n  .hl-row.warn { background: #fdf3e3; border-left-color: #EF9F27; }\n  .hl-row.ok { background: #eaf3de; border-left-color: #639922; }\n\n  \/* \u2500\u2500\u2500 Decision matrix \u2500\u2500\u2500 *\/\n  .decision-grid {\n    display: grid; grid-template-columns: 1fr 1fr; gap: 16px;\n    margin: 16px 0;\n  }\n  .decision-card {\n    border-radius: 10px; padding: 18px 20px;\n    border: 1px solid #e8e5df;\n  }\n  .decision-card.left { border-top: 3px solid #185FA5; }\n  .decision-card.right { border-top: 3px solid #639922; }\n  .decision-card h4 { font-size: 14px; font-weight: 600; margin-bottom: 12px; }\n  .decision-card ul { padding-left: 18px; }\n  .decision-card ul li { font-size: 13px; line-height: 1.8; color: #444; }\n\n  \/* \u2500\u2500\u2500 Timeline \u2500\u2500\u2500 *\/\n  .cost-bar { margin: 12px 0; }\n  .cost-bar-label { font-size: 12px; color: #666; margin-bottom: 4px; display: flex; justify-content: space-between; }\n  .cost-bar-track { height: 10px; border-radius: 5px; background: #e8e5df; overflow: hidden; }\n  .cost-bar-fill { height: 100%; border-radius: 5px; transition: width 0.4s; }\n\n  \/* \u2500\u2500\u2500 Metric cards \u2500\u2500\u2500 *\/\n  .metric-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(140px, 1fr)); gap: 12px; margin: 16px 0; }\n  .metric-card {\n    background: #f7f5f0; border-radius: 8px; padding: 14px 16px;\n  }\n  .metric-card .mc-label { font-size: 12px; color: #888; margin-bottom: 6px; }\n  .metric-card .mc-val { font-size: 20px; font-weight: 600; color: #1a2e4a; }\n  .metric-card .mc-note { font-size: 11px; color: #aaa; margin-top: 3px; }\n\n  \/* \u2500\u2500\u2500 Service \u2500\u2500\u2500 *\/\n  .service-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 12px; }\n  .service-item { display: flex; gap: 12px; align-items: flex-start; padding: 14px; border-radius: 8px; background: #fafaf8; border: 0.5px solid #e8e5df; }\n  .service-icon { width: 32px; height: 32px; border-radius: 8px; background: #1a2e4a; color: #fff; font-size: 14px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; }\n  .service-item-text .ti { font-size: 13px; font-weight: 600; color: #1a2e4a; }\n  .service-item-text .td { font-size: 12px; color: #888; margin-top: 2px; }\n\n  \/* \u2500\u2500\u2500 Footer \u2500\u2500\u2500 *\/\n  .footer {\n    text-align: center; padding: 32px 0 8px;\n    color: #aaa; font-size: 12px; line-height: 2;\n  }\n  .footer strong { color: #1a2e4a; font-size: 14px; }\n\n  \/* \u2500\u2500\u2500 Tag \u2500\u2500\u2500 *\/\n  .badge { display: inline-block; font-size: 11px; padding: 2px 8px; border-radius: 4px; font-weight: 500; margin-left: 6px; }\n  .badge-blue { background: #e6f1fb; color: #185FA5; }\n  .badge-green { background: #eaf3de; color: #3B6D11; }\n  .badge-amber { background: #faeeda; color: #854F0B; }\n\n  \/* \u2500\u2500\u2500 Print button \u2500\u2500\u2500 *\/\n  .print-btn {\n    position: fixed; bottom: 28px; right: 28px;\n    background: #1a2e4a; color: #fff;\n    border: none; border-radius: 8px;\n    padding: 10px 20px; font-size: 13px; cursor: pointer;\n    box-shadow: 0 2px 12px rgba(26,46,74,0.25);\n    z-index: 999;\n  }\n  .print-btn:hover { background: #233d63; }\n\n  @media (max-width: 600px) {\n    .cover { padding: 28px 22px; }\n    .section { padding: 20px 18px; }\n    .decision-grid { grid-template-columns: 1fr; }\n  }\n<\/style>\n\n<button class=\"print-btn no-print\" onclick=\"window.print()\">\u6253\u5370 \/ \u5bfc\u51faPDF<\/button>\n\n<div class=\"wrapper\">\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u5c01\u9762 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"cover\">\n    <div class=\"cover-tag\">\u65b9\u6848\u7f16\u53f7 WW-20260530-V1<\/div>\n    <h1>\u97e6\u5973\u58eb\u00b7\u5927\u5e73\u5c42<br>\u4e2d\u592e\u7a7a\u8c03 + \u5730\u6696\u65b9\u6848\u4e66<\/h1>\n    <div class=\"cover-sub\">\u83f2\u65af\u66fc vs \u5a01\u80fd \u00b7 \u5bf9\u6bd4\u7248<\/div>\n    <div class=\"cover-meta\">\n      <div class=\"cover-meta-item\"><label>\u5ba2\u6237<\/label><span>\u97e6\u5973\u58eb<\/span><\/div>\n      <div class=\"cover-meta-item\"><label>\u623f\u5c4b\u9762\u79ef<\/label><span>\u7ea6 220 \u33a1 \u5927\u5e73\u5c42<\/span><\/div>\n      <div class=\"cover-meta-item\"><label>\u4f4d\u7f6e<\/label><span>\u6210\u90fd\u5e02\u9526\u6c5f\u533a<\/span><\/div>\n      <div class=\"cover-meta-item\"><label>\u65b9\u6848\u65e5\u671f<\/label><span>2026\u5e745\u670830\u65e5<\/span><\/div>\n      <div class=\"cover-meta-item\"><label>\u9500\u552e\u987e\u95ee<\/label><span>\u8303\u4e3d\u5982<\/span><\/div>\n      <div class=\"cover-meta-item\"><label>\u8bbe\u8ba1\u5355\u4f4d<\/label><span>\u9f99\u8109\u6696\u901a\uff08\u59cb\u4e8e2004\uff09<\/span><\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e00\u3001\u914d\u7f6e\u603b\u89c8 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u4e00<\/div>\u9700\u6c42\u4e0e\u914d\u7f6e\u603b\u89c8<\/div>\n\n    <div class=\"section-sub\">1.1 &nbsp;\u65e5\u7acb\u4e2d\u592e\u7a7a\u8c03\u914d\u7f6e\uff08\u4e24\u65b9\u6848\u5171\u7528\uff09<\/div>\n    <p style=\"font-size:12px;color:#888;margin-bottom:10px;\">\n      \u8be6\u7ec6\u4ea7\u54c1\u4ecb\u7ecd\u8bf7\u53c2\u8003 \u2192 <a href=\"https:\/\/longmai-nt.com\/guide\/zunrui-shuimokuai.html\" target=\"_blank\">\u65e5\u7acb\u5c0a\u745e\u6c34\u6a21\u5757\u4ea7\u54c1\u6307\u5357<\/a>\n    <\/p>\n    <div class=\"tbl-wrap\">\n      <table>\n        <thead>\n          <tr>\n            <th>\u533a\u57df<\/th><th>\u5185\u673a\u578b\u53f7<\/th><th>\u5185\u673a\u51b7\u91cf<\/th><th>\u5339\u6570<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u5ba2\u5385<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td>7.1 kW<\/td><td>3 \u5339<\/td><\/tr>\n          <tr><td>\u9910\u5385<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td>5.0 kW<\/td><td>2 \u5339<\/td><\/tr>\n          <tr><td>\u4e3b\u5367<\/td><td>RPIZ-63FSVN2QB\/PC<\/td><td>6.3 kW<\/td><td>2.5 \u5339<\/td><\/tr>\n          <tr><td>\u6b21\u5367<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td>2.5 kW<\/td><td>1 \u5339<\/td><\/tr>\n          <tr><td>\u5973\u513f\u623f<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2 kW<\/td><td>1 \u5339<\/td><\/tr>\n          <tr><td>\u513f\u5b50\u623f<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td>2.2 kW<\/td><td>1 \u5339<\/td><\/tr>\n          <tr class=\"td-sum\"><td colspan=\"2\"><strong>6\u53f0\u5185\u673a\u5408\u8ba1<\/strong><\/td><td><strong>25.3 kW<\/strong><\/td><td>\u2014<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"tbl-wrap\" style=\"margin-top:14px;\">\n      <table>\n        <thead><tr><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u6838\u5fc3\u53c2\u6570<\/th><\/tr><\/thead>\n        <tbody>\n          <tr>\n            <td>\u5ba4\u5916\u673a<\/td>\n            <td>RAS-200FSXPN5Q<\/td>\n            <td>\u5236\u51b7 20.0 kW\uff0c\u5236\u70ed 22.4 kW\uff0cAPF 5.3\uff0c220V \u7535\u6e90<\/td>\n          <\/tr>\n          <tr>\n            <td>\u538b\u7f29\u673a<\/td>\n            <td>\u8865\u6c14\u589e\u7113\u6da1\u65cb\u538b\u7f29\u673a<\/td>\n            <td>-25\u2103 \u4f4e\u6e29\u5236\u70ed\uff0c60\u2103 \u9ad8\u6e29\u5236\u51b7<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"hl-row ok\">\n      <strong>\u8d85\u914d\u7387\u9a8c\u8bc1\uff1a<\/strong>25.3 kW \u00f7 20.0 kW = <strong>126.5%<\/strong>\uff0c\u5728\u5141\u8bb8\u533a\u95f4 50%\u2013130% \u5185\uff0c\u8bbe\u8ba1\u5408\u7406\u3002\n    <\/div>\n\n    <div class=\"section-sub\" style=\"margin-top:22px;\">1.2 &nbsp;\u5730\u6696\u914d\u7f6e\uff08\u4e24\u65b9\u6848\u5bf9\u6bd4\uff09<\/div>\n    <div class=\"compare-grid\">\n      <div class=\"compare-card featured\">\n        <h3>\u65b9\u6848 A &nbsp;<span class=\"badge badge-blue\">\u83f2\u65af\u66fc<\/span><\/h3>\n        <div class=\"brand-model\">B1JG 24kW \u00b7 \u56fd\u4ea7\u51b7\u51dd\u7089<\/div>\n        <a href=\"https:\/\/longmai-nt.com\/guide\/viessmann-b1jg.html\" target=\"_blank\" style=\"font-size:12px;\">\u67e5\u770b\u83f2\u65af\u66fc\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n        <div style=\"margin-top:12px;\">\n          <div class=\"compare-row\"><label>\u70ed\u6548\u7387<\/label><span>\u7ea6 105\u2013108%<\/span><\/div>\n          <div class=\"compare-row\"><label>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/label><span>\u7ea6 4\u20136 kW<\/span><\/div>\n          <div class=\"compare-row\"><label>\u4ea7\u5730<\/label><span>\u56fd\u4ea7<\/span><\/div>\n          <div class=\"compare-row\"><label>\u6362\u70ed\u5668<\/label><span>\u4e0d\u9508\u94a2\uff08Inox\u5f84\u5411\uff09<\/span><\/div>\n          <div class=\"compare-row\"><label>\u9002\u7528\u9762\u79ef<\/label><span>\u7ea6 150\u2013180 \u33a1<\/span><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"compare-card\">\n        <h3>\u65b9\u6848 B &nbsp;<span class=\"badge badge-green\">\u5a01\u80fd<\/span><\/h3>\n        <div class=\"brand-model\">LL1GBQ25-VUW 24KW \u00b7 \u56fd\u4ea7\u51b7\u51dd\u7089<\/div>\n        <a href=\"https:\/\/longmai-nt.com\/guide\/vaillant-intro.html\" target=\"_blank\" style=\"font-size:12px;\">\u67e5\u770b\u5a01\u80fd\u4ea7\u54c1\u8be6\u60c5 \u2192<\/a>\n        <div style=\"margin-top:12px;\">\n          <div class=\"compare-row\"><label>\u70ed\u6548\u7387<\/label><span>\u7ea6 105\u2013108%<\/span><\/div>\n          <div class=\"compare-row\"><label>\u6700\u5c0f\u8f93\u51fa\u529f\u7387<\/label><span>\u7ea6 5\u20137 kW<\/span><\/div>\n          <div class=\"compare-row\"><label>\u4ea7\u5730<\/label><span>\u56fd\u4ea7<\/span><\/div>\n          <div class=\"compare-row\"><label>\u6362\u70ed\u5668<\/label><span>\u4e0d\u9508\u94a2\uff08\u4e3b\u6362\u70ed\u5668\uff09<\/span><\/div>\n          <div class=\"compare-row\"><label>\u9002\u7528\u9762\u79ef<\/label><span>\u7ea6 150\u2013180 \u33a1<\/span><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <p style=\"font-size:12px;color:#888;\">\n      \u203b \u60a8\u5bb6 220\u33a1 \u5927\u5e73\u5c42\uff0c\u5730\u6696\u5b9e\u9645\u94fa\u8bbe\u9762\u79ef\u7ea6 150\u2013170\u33a1\uff08\u6263\u9664\u67dc\u4f53\u3001\u536b\u751f\u95f4\u7b49\uff09\uff0c24 kW \u51b7\u51dd\u7089\u8db3\u591f\u3002\n    <\/p>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e8c\u3001\u6838\u5fc3\u5dee\u5f02 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u4e8c<\/div>\u4e24\u6b3e\u51b7\u51dd\u7089\u6838\u5fc3\u5dee\u5f02<\/div>\n\n    <div class=\"section-sub\">2.1 &nbsp;\u6280\u672f\u53c2\u6570\u5bf9\u6bd4<\/div>\n    <div class=\"tbl-wrap\">\n      <table>\n        <thead>\n          <tr><th>\u53c2\u6570<\/th><th>\u83f2\u65af\u66fc B1JG 24kW<\/th><th>\u5a01\u80fd VUW 24kW<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u6362\u70ed\u5668\u6750\u8d28<\/td><td>\u4e0d\u9508\u94a2\uff08Inox \u5f84\u5411\uff09<\/td><td>\u4e0d\u9508\u94a2\uff08\u4e3b\u6362\u70ed\u5668\uff09<\/td><\/tr>\n          <tr><td>\u8c03\u8282\u6bd4<\/td><td>\u7ea6 1:4<\/td><td>\u7ea6 1:5<\/td><\/tr>\n          <tr><td>\u6c2e\u6c27\u5316\u7269\u6392\u653e<\/td><td>Class 5\uff08\u4f4e\u6c2e\uff09<\/td><td>Class 5\uff08\u4f4e\u6c2e\uff09<\/td><\/tr>\n          <tr><td>\u751f\u6d3b\u70ed\u6c34\u6d41\u91cf\uff08\u0394T=30\u2103\uff09<\/td><td>\u7ea6 11.5 L\/min<\/td><td>\u7ea6 11.5 L\/min<\/td><\/tr>\n          <tr><td>\u63a7\u5236\u517c\u5bb9\u6027<\/td><td>\u5ba4\u6e29\u8054\u52a8\u3001OT \u534f\u8bae<\/td><td>eBus \u534f\u8bae<\/td><\/tr>\n          <tr><td>\u552e\u540e\u7f51\u7edc<\/td><td>\u83f2\u65af\u66fc\u6388\u6743\u670d\u52a1\u5546<\/td><td>\u5a01\u80fd\u6388\u6743\u670d\u52a1\u5546<\/td><\/tr>\n          <tr><td>\u5e02\u573a\u53e3\u7891<\/td><td>\"\u9505\u7089\u754c\u7684\u5954\u9a70\"\uff0c\u6362\u70ed\u5668\u8010\u7528<\/td><td>\u5e02\u573a\u5360\u6709\u7387\u9ad8\uff0c\u914d\u4ef6\u6613\u5f97<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"section-sub\" style=\"margin-top:22px;\">2.2 &nbsp;\u9488\u5bf9\u60a8\u5bb6\u7684\u9002\u914d\u5efa\u8bae<\/div>\n    <div class=\"tbl-wrap\">\n      <table>\n        <thead>\n          <tr><th>\u8003\u91cf\u7ef4\u5ea6<\/th><th>\u83f2\u65af\u66fc<\/th><th>\u5a01\u80fd<\/th><th>\u7efc\u5408\u5efa\u8bae<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u91c7\u6696\u6548\u7387<\/td><td colspan=\"2\" class=\"td-center\">\u4e24\u8005\u76f8\u5f53\uff0c\u90fd\u662f\u5fb7\u7cfb\u4e00\u7ebf<\/td><td class=\"td-mute\">\u65e0\u660e\u663e\u5dee\u5f02<\/td><\/tr>\n          <tr><td>\u6700\u5c0f\u529f\u7387\u5339\u914d<\/td><td>4\u20136 kW <span class=\"badge badge-blue\">\u7565\u4f18<\/span><\/td><td>5\u20137 kW<\/td><td>\u83f2\u65af\u66fc\u4f4e\u9891\u66f4\u7a33<\/td><\/tr>\n          <tr><td>\u60a8\u5bb6\u540c\u5f00\u7387<\/td><td colspan=\"2\" class=\"td-center\">220\u33a1 \u5927\u5e73\u5c42\uff0c\u65e5\u5e38\u53ef\u80fd\u5f00 1\u20132 \u533a\u57df<\/td><td class=\"td-mute\">\u4e24\u8005\u90fd\u80fd\u6ee1\u8db3<\/td><\/tr>\n          <tr><td>\u552e\u540e\u4fbf\u5229\u6027<\/td><td>\u6210\u90fd\u5747\u6709\u6388\u6743\u670d\u52a1\u5546<\/td><td>\u5a01\u80fd\u7f51\u70b9\u7565\u591a<\/td><td class=\"td-mute\">\u5dee\u5f02\u4e0d\u5927<\/td><\/tr>\n          <tr><td>\u4ef7\u683c<\/td><td>\u7565\u4f4e\u4e8e\u5a01\u80fd <span class=\"badge badge-blue\">\u66f4\u5212\u7b97<\/span><\/td><td>\u7565\u9ad8\u4e8e\u83f2\u65af\u66fc<\/td><td>\u83f2\u65af\u66fc\u6027\u4ef7\u6bd4\u66f4\u9ad8<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"hl-row\" style=\"margin-top:16px;\">\n      <strong>\u4e00\u53e5\u8bdd\u7ed3\u8bba\uff1a<\/strong>\u4e24\u6b3e\u90fd\u662f\u5fb7\u7cfb\u4e00\u7ebf\u51b7\u51dd\u7089\uff0c\u6280\u672f\u6210\u719f\u3001\u54c1\u8d28\u53ef\u9760\u3002<strong>\u83f2\u65af\u66fc\u6027\u4ef7\u6bd4\u7565\u9ad8\uff0c\u5a01\u80fd\u5e02\u573a\u53e3\u7891\u66f4\u5e7f\u3002<\/strong>\u9009\u54ea\u4e2a\u90fd\u4e0d\u4f1a\u9519\uff0c\u4e3b\u8981\u770b\u60a8\u5bf9\u54c1\u724c\u504f\u597d\u548c\u9884\u7b97\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e09\u3001\u62a5\u4ef7\u5bf9\u6bd4 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section page-break\">\n    <div class=\"section-title\"><div class=\"num\">\u4e09<\/div>\u4e24\u5957\u65b9\u6848\u62a5\u4ef7\u5bf9\u6bd4\uff08\u7a7a\u8c03\u8bbe\u5907 8 \u6298\uff09<\/div>\n\n    <div class=\"section-sub\">3.1 &nbsp;\u7a7a\u8c03\u90e8\u5206\uff08\u4e24\u65b9\u6848\u5171\u7528\uff09<\/div>\n    <div class=\"tbl-wrap\">\n      <table>\n        <thead>\n          <tr><th>\u8bbe\u5907\u7c7b\u578b<\/th><th>\u578b\u53f7<\/th><th>\u6570\u91cf<\/th><th class=\"td-right\">\u9762\u4ef7<\/th><th class=\"td-right\">8\u6298\u540e<\/th><th class=\"td-right\">\u5b89\u88c5\u8d39\/\u53f0<\/th><th class=\"td-right\">\u5b89\u88c5\u8d39\u5408\u8ba1<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u5ba4\u5916\u673a<\/td><td>RAS-200FSXPN5Q<\/td><td class=\"td-center\">1<\/td><td class=\"td-right\">25,863<\/td><td class=\"td-right\">20,690<\/td><td class=\"td-right\">600<\/td><td class=\"td-right\">600<\/td><\/tr>\n          <tr><td>\u5185\u673a 71<\/td><td>RPIZ-71FSVN2QB\/PC<\/td><td class=\"td-center\">1<\/td><td class=\"td-right\">5,825<\/td><td class=\"td-right\">4,660<\/td><td class=\"td-right\">1,900<\/td><td class=\"td-right\">1,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 63<\/td><td>RPIZ-63FSVN2QB\/PC<\/td><td class=\"td-center\">1<\/td><td class=\"td-right\">5,825<\/td><td class=\"td-right\">4,660<\/td><td class=\"td-right\">1,900<\/td><td class=\"td-right\">1,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 50<\/td><td>RPIZ-50FSVN2QB\/PC<\/td><td class=\"td-center\">1<\/td><td class=\"td-right\">5,663<\/td><td class=\"td-right\">4,530<\/td><td class=\"td-right\">1,900<\/td><td class=\"td-right\">1,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 25<\/td><td>RPIZ-25FSVN2QB\/PC<\/td><td class=\"td-center\">1<\/td><td class=\"td-right\">5,050<\/td><td class=\"td-right\">4,040<\/td><td class=\"td-right\">1,900<\/td><td class=\"td-right\">1,900<\/td><\/tr>\n          <tr><td>\u5185\u673a 22<\/td><td>RPIZ-22FSVN2QB\/PC<\/td><td class=\"td-center\">2<\/td><td class=\"td-right\">5,050\u00d72<\/td><td class=\"td-right\">8,080<\/td><td class=\"td-right\">1,900\u00d72<\/td><td class=\"td-right\">3,800<\/td><\/tr>\n          <tr class=\"td-sum\">\n            <td colspan=\"4\"><strong>\u7a7a\u8c03\u8bbe\u5907\u5c0f\u8ba1<\/strong><\/td>\n            <td class=\"td-right\"><strong>46,660<\/strong><\/td>\n            <td class=\"td-right\">\u2014<\/td>\n            <td class=\"td-right\"><strong>12,000<\/strong><\/td>\n          <\/tr>\n          <tr><td colspan=\"4\">\u8f85\u6750\u4e0e\u4eba\u5de5\uff08\u94dc\u7ba1\u3001\u4fdd\u6e29\u3001\u51b7\u51dd\u6c34\u7ba1\u3001\u5f00\u5b54\u7b49\uff09<\/td><td colspan=\"3\" class=\"td-right\">\u7ea6 5,000<\/td><\/tr>\n          <tr class=\"td-sum\"><td colspan=\"4\"><strong>\u7a7a\u8c03\u5408\u8ba1<\/strong><\/td><td colspan=\"3\" class=\"td-right\"><strong>\u7ea6 63,660 \u5143<\/strong><\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"section-sub\" style=\"margin-top:22px;\">3.2 &nbsp;\u5730\u6696\u57fa\u7840\u90e8\u5206\uff08220\u33a1 \u5927\u5e73\u5c42\u4f30\u7b97\uff09<\/div>\n    <div class=\"tbl-wrap\">\n      <table>\n        <thead><tr><th>\u9879\u76ee<\/th><th>\u914d\u7f6e<\/th><th>\u5355\u4ef7<\/th><th class=\"td-right\">\u603b\u4ef7<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>\u5730\u6696\u76d8\u7ba1 + \u5206\u96c6\u6c34\u5668<\/td><td>\u4f1f\u661f\u963b\u6c27 PE-RT De20<\/td><td>179\u5143\/\u33a1\uff08\u6309\u5b9e\u94fa 150\u33a1\uff09<\/td><td class=\"td-right\">26,850 \u5143<\/td><\/tr>\n          <tr><td>\u627e\u5e73\u5c42\uff08\u56de\u586b\uff09<\/td><td>\u8c46\u77f3\u6df7\u51dd\u571f<\/td><td>30\u5143\/\u33a1 \u00d7 150\u33a1<\/td><td class=\"td-right\">4,500 \u5143<\/td><\/tr>\n          <tr><td>\u6e29\u63a7 + \u8054\u52a8<\/td><td>\u66fc\u745e\u5fb7 WiFi \u7ebf\u63a7 + \u8054\u52a8\u63a7\u5236\u5668<\/td><td>980\u5143\/\u5c42<\/td><td class=\"td-right\">980 \u5143<\/td><\/tr>\n          <tr class=\"td-sum\"><td colspan=\"3\"><strong>\u5730\u6696\u57fa\u7840\u90e8\u5206\u5c0f\u8ba1<\/strong><\/td><td class=\"td-right\"><strong>\u7ea6 32,330 \u5143<\/strong><\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"section-sub\" style=\"margin-top:22px;\">3.3\u20133.4 &nbsp;\u7089\u4f53\u65b9\u6848\u5bf9\u6bd4<\/div>\n    <div class=\"compare-grid\">\n      <!-- \u65b9\u6848A -->\n      <div class=\"compare-card featured\">\n        <h3>\u65b9\u6848 A &nbsp;\u83f2\u65af\u66fc<\/h3>\n        <div class=\"brand-model\">B1JG 24kW<\/div>\n        <div class=\"compare-row\"><label>\u7089\u4f53\u9762\u4ef7<\/label><span>12,238 \u5143<\/span><\/div>\n        <div class=\"compare-row\"><label>\u5b89\u88c5\u8d39<\/label><span>600 \u5143<\/span><\/div>\n        <div class=\"compare-row\"><label>\u7089\u4f53\u5c0f\u8ba1<\/label><span style=\"color:#185FA5;font-weight:600;\">12,838 \u5143<\/span><\/div>\n        <div style=\"margin-top:14px;border-top:1px solid #e8e5df;padding-top:14px;\">\n          <div class=\"compare-row\"><label>\u7a7a\u8c03\u5408\u8ba1<\/label><span>63,660 \u5143<\/span><\/div>\n          <div class=\"compare-row\"><label>\u5730\u6696\u57fa\u7840<\/label><span>32,330 \u5143<\/span><\/div>\n          <div class=\"compare-row\"><label>\u7089\u4f53+\u5b89\u88c5<\/label><span>12,838 \u5143<\/span><\/div>\n          <div style=\"background:#e6f1fb;border-radius:6px;padding:10px 12px;margin-top:10px;display:flex;justify-content:space-between;align-items:center;\">\n            <span style=\"font-size:13px;font-weight:600;color:#185FA5;\">\u65b9\u6848A \u603b\u8ba1<\/span>\n            <span style=\"font-size:20px;font-weight:700;color:#185FA5;\">\u7ea6 108,828 \u5143<\/span>\n          <\/div>\n        <\/div>\n      <\/div>\n      <!-- \u65b9\u6848B -->\n      <div class=\"compare-card\">\n        <h3>\u65b9\u6848 B &nbsp;\u5a01\u80fd<\/h3>\n        <div class=\"brand-model\">LL1GBQ25-VUW 24KW<\/div>\n        <div class=\"compare-row\"><label>\u7089\u4f53\u9762\u4ef7<\/label><span>14,284 \u5143<\/span><\/div>\n        <div class=\"compare-row\"><label>\u5b89\u88c5\u8d39<\/label><span>600 \u5143<\/span><\/div>\n        <div class=\"compare-row\"><label>\u7089\u4f53\u5c0f\u8ba1<\/label><span>14,884 \u5143<\/span><\/div>\n        <div style=\"margin-top:14px;border-top:1px solid #e8e5df;padding-top:14px;\">\n          <div class=\"compare-row\"><label>\u7a7a\u8c03\u5408\u8ba1<\/label><span>63,660 \u5143<\/span><\/div>\n          <div class=\"compare-row\"><label>\u5730\u6696\u57fa\u7840<\/label><span>32,330 \u5143<\/span><\/div>\n          <div class=\"compare-row\"><label>\u7089\u4f53+\u5b89\u88c5<\/label><span>14,884 \u5143<\/span><\/div>\n          <div style=\"background:#f7f5f0;border-radius:6px;padding:10px 12px;margin-top:10px;display:flex;justify-content:space-between;align-items:center;\">\n            <span style=\"font-size:13px;font-weight:600;color:#444;\">\u65b9\u6848B \u603b\u8ba1<\/span>\n            <span style=\"font-size:20px;font-weight:700;color:#444;\">\u7ea6 110,874 \u5143<\/span>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"hl-row ok\">\n      <strong>\u4ef7\u5dee\u5c0f\u7ed3\uff1a<\/strong>\u83f2\u65af\u66fc\u65b9\u6848\u6bd4\u5a01\u80fd\u65b9\u6848\u4fbf\u5b9c\u7ea6 <strong>2,046 \u5143<\/strong>\u3002\u4e24\u8005\u54c1\u8d28\u76f8\u5f53\uff0c\u83f2\u65af\u66fc\u6027\u4ef7\u6bd4\u66f4\u9ad8\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u56db\u300120\u5e74\u603b\u6295\u5165 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u56db<\/div>20 \u5e74\u603b\u6295\u5165\u5bf9\u6bd4<\/div>\n\n    <div class=\"metric-grid\">\n      <div class=\"metric-card\">\n        <div class=\"mc-label\">\u65b9\u6848A 20\u5e74\u603b\u6295\u5165<\/div>\n        <div class=\"mc-val\" style=\"color:#185FA5;\">24.7\u4e07<\/div>\n        <div class=\"mc-note\">\u83f2\u65af\u66fc\u65b9\u6848<\/div>\n      <\/div>\n      <div class=\"metric-card\">\n        <div class=\"mc-label\">\u65b9\u6848B 20\u5e74\u603b\u6295\u5165<\/div>\n        <div class=\"mc-val\" style=\"color:#444;\">25.1\u4e07<\/div>\n        <div class=\"mc-note\">\u5a01\u80fd\u65b9\u6848<\/div>\n      <\/div>\n      <div class=\"metric-card\">\n        <div class=\"mc-label\">20\u5e74\u5dee\u989d<\/div>\n        <div class=\"mc-val\" style=\"color:#639922;\">4,046\u5143<\/div>\n        <div class=\"mc-note\">\u83f2\u65af\u66fc\u66f4\u7701<\/div>\n      <\/div>\n      <div class=\"metric-card\">\n        <div class=\"mc-label\">20\u5e74\u91c7\u6696\u8d39\uff08\u4f30\u7b97\uff09<\/div>\n        <div class=\"mc-val\">12\u4e07<\/div>\n        <div class=\"mc-note\">\u4e24\u8005\u76f8\u540c<\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"tbl-wrap\" style=\"margin-top:16px;\">\n      <table>\n        <thead><tr><th>\u8d39\u7528\u9879<\/th><th class=\"td-right\">\u65b9\u6848A\uff08\u83f2\u65af\u66fc\uff09<\/th><th class=\"td-right\">\u65b9\u6848B\uff08\u5a01\u80fd\uff09<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>\u521d\u6295\u8d44<\/td><td class=\"td-right\">108,828 \u5143<\/td><td class=\"td-right\">110,874 \u5143<\/td><\/tr>\n          <tr><td>20\u5e74\u91c7\u6696\u8d39\uff08\u4f30\u7b97\uff09<\/td><td class=\"td-right\">\u7ea6 120,000 \u5143<\/td><td class=\"td-right\">\u7ea6 120,000 \u5143<\/td><\/tr>\n          <tr><td>20\u5e74\u5185\u7089\u4f53\u66f4\u6362\uff081\u6b21\uff09<\/td><td class=\"td-right\">+13,000 \u5143<\/td><td class=\"td-right\">+15,000 \u5143<\/td><\/tr>\n          <tr><td>20\u5e74\u7ef4\u4fdd\u8d39\u7528<\/td><td class=\"td-right\">\u7ea6 5,000 \u5143<\/td><td class=\"td-right\">\u7ea6 5,000 \u5143<\/td><\/tr>\n          <tr class=\"td-sum\">\n            <td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td>\n            <td class=\"td-right\"><strong style=\"color:#185FA5;\">\u7ea6 246,828 \u5143<\/strong><\/td>\n            <td class=\"td-right\"><strong>\u7ea6 250,874 \u5143<\/strong><\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div style=\"margin-top:18px;\">\n      <p style=\"font-size:12px;color:#888;margin-bottom:10px;\">20\u5e74\u603b\u6295\u5165\u53ef\u89c6\u5316\u5bf9\u6bd4<\/p>\n      <div class=\"cost-bar\">\n        <div class=\"cost-bar-label\"><span>\u65b9\u6848A \u83f2\u65af\u66fc<\/span><span style=\"color:#185FA5;font-weight:600;\">246,828 \u5143<\/span><\/div>\n        <div class=\"cost-bar-track\"><div class=\"cost-bar-fill\" style=\"width:98%;background:#185FA5;\"><\/div><\/div>\n      <\/div>\n      <div class=\"cost-bar\" style=\"margin-top:10px;\">\n        <div class=\"cost-bar-label\"><span>\u65b9\u6848B \u5a01\u80fd<\/span><span style=\"color:#888;font-weight:500;\">250,874 \u5143<\/span><\/div>\n        <div class=\"cost-bar-track\"><div class=\"cost-bar-fill\" style=\"width:100%;background:#bbb;\"><\/div><\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"hl-row ok\" style=\"margin-top:16px;\">\n      \u5a01\u80fd 20 \u5e74\u603b\u6295\u5165\u6bd4\u83f2\u65af\u66fc\u9ad8\u7ea6 <strong>4,046 \u5143<\/strong>\uff08\u542b\u521d\u6295\u8d44 + \u66f4\u6362\u6210\u672c\u5dee\u5f02\uff09\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e94\u3001\u9009\u8d2d\u5efa\u8bae \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u4e94<\/div>\u9488\u5bf9\u60a8\u5bb6\u7684\u9009\u8d2d\u5efa\u8bae<\/div>\n\n    <div class=\"decision-grid\">\n      <div class=\"decision-card left\">\n        <h4>\u9009\u83f2\u65af\u66fc\uff08\u65b9\u6848A\uff09\u5982\u679c\u2026\u2026<\/h4>\n        <ul>\n          <li>\u6027\u4ef7\u6bd4\u4f18\u5148\uff0c\u4e24\u6b3e\u5fb7\u7cfb\u54c1\u8d28\u76f8\u5f53\uff0c\u9009\u66f4\u5b9e\u60e0\u7684<\/li>\n          <li>\u521d\u6295\u8d44\u7701 2,000 \u5143\uff0c20 \u5e74\u603b\u6295\u5165\u7701 4,000 \u5143<\/li>\n          <li>\u5728\u610f\u4f4e\u9891\u8fd0\u884c\u7a33\u5b9a\u6027\uff08\u6700\u5c0f\u529f\u7387 4\u20136 kW \u7565\u4f18\uff09<\/li>\n          <li>\u6210\u90fd\u6709\u6388\u6743\u670d\u52a1\u5546\uff0c\u552e\u540e\u65e0\u5fe7<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"decision-card right\">\n        <h4>\u9009\u5a01\u80fd\uff08\u65b9\u6848B\uff09\u5982\u679c\u2026\u2026<\/h4>\n        <ul>\n          <li>\u54c1\u724c\u77e5\u540d\u5ea6\u4f18\u5148\uff0c\u5a01\u80fd\u5e02\u573a\u5360\u6709\u7387\u66f4\u9ad8<\/li>\n          <li>\u8eab\u8fb9\u670b\u53cb\u7528\u7684\u4eba\u591a\uff0c\u5fc3\u7406\u6ee1\u8db3\u611f\u66f4\u5f3a<\/li>\n          <li>\u9884\u7b97\u5145\u8db3\uff0c\u613f\u610f\u4e3a\u54c1\u724c\u6ea2\u4ef7 2,000 \u5143\u4ed8\u8d39<\/li>\n          <li>\u770b\u91cd\u914d\u4ef6\u591a\u3001\u7f51\u70b9\u7565\u5e7f\u7684\u552e\u540e\u4f53\u7cfb<\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n\n    <div class=\"hl-row\" style=\"margin-top:8px;\">\n      <strong>\u6838\u5fc3\u5efa\u8bae\uff1a<\/strong>\u4e24\u6b3e\u90fd\u662f\u5fb7\u7cfb\u4e00\u7ebf\u51b7\u51dd\u7089\uff0c\u6280\u672f\u6210\u719f\u3001\u54c1\u8d28\u53ef\u9760\u3002\u4ece\u7eaf\u7406\u6027\u89d2\u5ea6\uff0c<strong>\u83f2\u65af\u66fc\u66f4\u5212\u7b97<\/strong>\uff1b\u4ece\u5fc3\u7406\u6ee1\u8db3\u89d2\u5ea6\uff0c<strong>\u5a01\u80fd\u4e5f\u4e0d\u4e8f<\/strong>\u3002\u9009\u54ea\u4e2a\u90fd\u5bf9\uff0c\u4e3b\u8981\u770b\u60a8\u81ea\u5df1\u503e\u5411\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u516d\u3001\u4e24\u8054\u4f9b\u8865\u5145\u8bf4\u660e \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u516d<\/div>\u4e24\u8054\u4f9b vs \u7a7a\u8c03+\u9505\u7089 \u00b7 \u8865\u5145\u8bf4\u660e<\/div>\n    <p style=\"font-size:13px;color:#555;margin-bottom:16px;\">\u60a8\u76ee\u524d\u9009\u62e9\u7684\u662f\u300c\u7a7a\u8c03 + \u9505\u7089\u300d\u65b9\u6848\u3002\u5982\u679c\u60a8\u613f\u610f\u8003\u8651\u7a7a\u6c14\u80fd\u5e26\u5730\u6696\uff08\u4e24\u8054\u4f9b\uff09\uff0c\u53ef\u4ee5\u8fdb\u4e00\u6b65\u8282\u80fd\uff1a<\/p>\n\n    <div class=\"tbl-wrap\">\n      <table>\n        <thead>\n          <tr><th>\u5bf9\u6bd4\u9879<\/th><th>\u7a7a\u8c03+\u9505\u7089\uff08\u5f53\u524d\u65b9\u6848\uff09<\/th><th>\u4e24\u8054\u4f9b\uff08\u7a7a\u6c14\u80fd\u5e26\u5730\u6696\uff09<\/th><\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td>\u5730\u6696\u6708\u8d39\uff08220\u33a1\uff09<\/td><td>\u7ea6 2,000\u20133,000 \u5143<\/td><td>\u7ea6 1,000\u20131,500 \u5143 <span class=\"badge badge-green\">\u8282\u7701\u7ea650%<\/span><\/td><\/tr>\n          <tr><td>20\u5e74\u5730\u6696\u603b\u8d39\u7528<\/td><td>\u7ea6 120,000 \u5143<\/td><td>\u7ea6 60,000 \u5143<\/td><\/tr>\n          <tr><td>\u521d\u6295\u8d44<\/td><td>\u7ea6 11 \u4e07<\/td><td>\u7ea6 13\u201314 \u4e07\uff08\u542b\u7a7a\u8c03+\u5730\u6696+\u6c34\u6a21\u5757\uff09<\/td><\/tr>\n          <tr><td>\u8bbe\u5907\u5bff\u547d<\/td><td>\u9505\u7089 8\u201310 \u5e74\u6362\u4e00\u6b21<\/td><td>\u5916\u673a 20 \u5e74+\uff0c\u65e0\u9700\u6362\u9505\u7089<\/td><\/tr>\n          <tr class=\"td-sum\"><td><strong>20\u5e74\u603b\u6295\u5165<\/strong><\/td><td><strong>\u7ea6 25 \u4e07<\/strong><\/td><td><strong style=\"color:#3B6D11;\">\u7ea6 20\u201322 \u4e07<\/strong><\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"hl-row warn\" style=\"margin-top:14px;\">\n      \u5982\u679c\u60a8\u5bf9\u957f\u671f\u8282\u80fd\u66f4\u770b\u91cd\uff0c\u6211\u4eec\u53ef\u4ee5\u4e3a\u60a8\u5355\u72ec\u505a\u4e00\u7248<strong>\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4<\/strong>\uff0c\u968f\u65f6\u544a\u8bc9\u987e\u95ee\u8303\u4e3d\u5982\u5373\u53ef\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u4e03\u3001\u670d\u52a1\u627f\u8bfa \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u4e03<\/div>\u670d\u52a1\u627f\u8bfa<\/div>\n    <div class=\"service-grid\">\n      <div class=\"service-item\">\n        <div class=\"service-icon\">48h<\/div>\n        <div class=\"service-item-text\">\n          <div class=\"ti\">\u514d\u8d39\u4e0a\u95e8\u52d8\u6d4b<\/div>\n          <div class=\"td\">48 \u5c0f\u65f6\u5185\u54cd\u5e94<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"service-item\">\n        <div class=\"service-icon\">2+<\/div>\n        <div class=\"service-item-text\">\n          <div class=\"ti\">\u591a\u65b9\u6848\u5bf9\u6bd4<\/div>\n          <div class=\"td\">\u4e0d\u5c11\u4e8e 2 \u5957\u8bbe\u8ba1\u65b9\u6848<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"service-item\">\n        <div class=\"service-icon\">\u2713<\/div>\n        <div class=\"service-item-text\">\n          <div class=\"ti\">\u6807\u51c6\u65bd\u5de5\u89c4\u8303<\/div>\n          <div class=\"td\">\u65e5\u7acb\u7cbe\u5de5\u7cbe\u5320\u6807\u51c6<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"service-item\">\n        <div class=\"service-icon\">\u00a5<\/div>\n        <div class=\"service-item-text\">\n          <div class=\"ti\">\u900f\u660e\u62a5\u4ef7\u4f53\u7cfb<\/div>\n          <div class=\"td\">\u65e0\u9690\u85cf\u589e\u9879<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"service-item\">\n        <div class=\"service-icon\">5Y<\/div>\n        <div class=\"service-item-text\">\n          <div class=\"ti\">5 \u5e74\u8d77\u5de5\u7a0b\u8d28\u4fdd<\/div>\n          <div class=\"td\">\u8fdc\u8d85\u884c\u4e1a\u6807\u51c6<\/div>\n        <\/div>\n      <\/div>\n      <div class=\"service-item\">\n        <div class=\"service-icon\">\u221e<\/div>\n        <div class=\"service-item-text\">\n          <div class=\"ti\">\u7ec8\u8eab\u4f1a\u5458\u670d\u52a1<\/div>\n          <div class=\"td\">\u5e74\u5ea6\u68c0\u6d4b + \u7ef4\u4fdd\u63d0\u9192<\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 \u516b\u3001\u9644\u6ce8 \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"section\">\n    <div class=\"section-title\"><div class=\"num\">\u516b<\/div>\u65b9\u6848\u4e66\u9644\u6ce8<\/div>\n    <p style=\"font-size:13px;color:#555;line-height:1.9;\">\n      \u672c\u65b9\u6848\u6240\u6709\u6280\u672f\u53c2\u6570\u3001\u8bbe\u8ba1\u903b\u8f91\u5747\u5f15\u7528 <strong>GB 50736-2012<\/strong>\u3001\u65e5\u7acb\u5b98\u65b9\u6280\u672f\u624b\u518c\u3001\u83f2\u65af\u66fc \/ \u5a01\u80fd\u5b98\u65b9\u6280\u672f\u53c2\u6570\u7b49\u516c\u5f00\u6807\u51c6\uff0c\u60a8\u6216\u4efb\u4f55\u7b2c\u4e09\u65b9\u5747\u53ef\u72ec\u7acb\u9a8c\u8bc1\u3002\n    <\/p>\n    <div style=\"margin-top:16px;border-top:1px solid #e8e5df;padding-top:16px;\">\n      <p style=\"font-size:13px;font-weight:600;color:#1a2e4a;margin-bottom:10px;\">\u4e24\u6b3e\u7089\u5b50\u6838\u5fc3\u5dee\u5f02\u5c0f\u7ed3<\/p>\n      <div style=\"display:grid;grid-template-columns:1fr 1fr;gap:12px;\">\n        <div style=\"background:#e6f1fb;border-radius:8px;padding:14px 16px;\">\n          <div style=\"font-size:13px;font-weight:600;color:#185FA5;margin-bottom:8px;\">\u83f2\u65af\u66fc \u00b7 \u65b9\u6848A<\/div>\n          <div style=\"font-size:13px;color:#333;line-height:1.8;\">\n            \u521d\u6295\u8d44\u4f4e 2,000 \u5143<br>\n            20 \u5e74\u603b\u6295\u5165\u4f4e 4,000 \u5143<br>\n            \u6700\u5c0f\u529f\u7387 4\u20136 kW\uff0c\u4f4e\u9891\u66f4\u7a33<br>\n            <strong>\u6027\u4ef7\u6bd4\u66f4\u9ad8<\/strong>\n          <\/div>\n        <\/div>\n        <div style=\"background:#f7f5f0;border-radius:8px;padding:14px 16px;\">\n          <div style=\"font-size:13px;font-weight:600;color:#444;margin-bottom:8px;\">\u5a01\u80fd \u00b7 \u65b9\u6848B<\/div>\n          <div style=\"font-size:13px;color:#333;line-height:1.8;\">\n            \u5e02\u573a\u5360\u6709\u7387\u66f4\u9ad8<br>\n            \u914d\u4ef6\u548c\u552e\u540e\u7f51\u70b9\u7565\u591a<br>\n            \u54c1\u724c\u6ea2\u4ef7\u7ea6 2,000 \u5143<br>\n            <strong>\u54c1\u724c\u77e5\u540d\u5ea6\u66f4\u5e7f<\/strong>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n    <div class=\"hl-row\" style=\"margin-top:16px;\">\n      \u9009\u54ea\u4e2a\u90fd\u4e0d\u9519\uff0c\u4e3b\u8981\u770b\u60a8\u5bf9\u54c1\u724c\u7684\u504f\u597d\u3002\u5982\u9700\u4e24\u8054\u4f9b\u65b9\u6848\u5bf9\u6bd4\uff0c\u968f\u65f6\u544a\u8bc9\u6211\u3002\n    <\/div>\n  <\/div>\n\n  <!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 Footer \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 -->\n  <div class=\"footer\">\n    <strong>\u9f99\u8109\u6696\u901a \u00b7 \u59cb\u4e8e 2004<\/strong><br>\n    \u4ea4\u4ed8\u4e0d\u662f\u7ec8\u70b9\uff0c\u800c\u662f\u670d\u52a1\u7684\u5f00\u59cb<br><br>\n    \u9500\u552e\u987e\u95ee\uff1a\u8303\u4e3d\u5982 &nbsp;|&nbsp; \u8054\u7cfb\u7535\u8bdd\uff1a13398198375<br>\n    \u95e8\u5e97\u5730\u5740\uff1a\u5bcc\u68ee\u7f8e\u5bb6\u5c45\u5efa\u6750\u9986\u4e09\u697c A-348<br><br>\n    <span style=\"color:#ccc;\">\u65b9\u6848\u7f16\u53f7\uff1aWW-20260530-V1 &nbsp;|&nbsp; \u65b9\u6848\u65e5\u671f\uff1a2026\u5e745\u670830\u65e5<\/span>\n  <\/div>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u6253\u5370 \/ \u5bfc\u51faPDF \u65b9\u6848\u7f16\u53f7 WW-2 [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2653","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u97e6\u5973\u58eb\u5927\u5e73\u5c42 - \u9f99\u8109\u6696\u901a<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longmai-nt.com\/?page_id=2653\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u97e6\u5973\u58eb\u5927\u5e73\u5c42 - \u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"og:description\" content=\"\u6253\u5370 \/ \u5bfc\u51faPDF \u65b9\u6848\u7f16\u53f7 WW-2 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longmai-nt.com\/?page_id=2653\" \/>\n<meta property=\"og:site_name\" content=\"\u9f99\u8109\u6696\u901a\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-13T08:24:32+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2653\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2653\",\"name\":\"\u97e6\u5973\u58eb\u5927\u5e73\u5c42 - \u9f99\u8109\u6696\u901a\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\"},\"datePublished\":\"2026-06-09T04:59:37+00:00\",\"dateModified\":\"2026-06-13T08:24:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2653#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2653\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/?page_id=2653#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/longmai-nt.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u97e6\u5973\u58eb\u5927\u5e73\u5c42\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#website\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"description\":\"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1\",\"publisher\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\"},\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/longmai-nt.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#organization\",\"name\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\",\"alternateName\":\"\u9f99\u8109\u6696\u901a\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/longmai-nt.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo.png\",\"width\":516,\"height\":478,\"caption\":\"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\\\/\\\/longmai-nt.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.xiaohongshu.com\\\/user\\\/profile\\\/5fe8a4e800000000010058d2\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u97e6\u5973\u58eb\u5927\u5e73\u5c42 - \u9f99\u8109\u6696\u901a","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longmai-nt.com\/?page_id=2653","og_locale":"zh_CN","og_type":"article","og_title":"\u97e6\u5973\u58eb\u5927\u5e73\u5c42 - \u9f99\u8109\u6696\u901a","og_description":"\u6253\u5370 \/ \u5bfc\u51faPDF \u65b9\u6848\u7f16\u53f7 WW-2 [&hellip;]","og_url":"https:\/\/longmai-nt.com\/?page_id=2653","og_site_name":"\u9f99\u8109\u6696\u901a","article_modified_time":"2026-06-13T08:24:32+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/longmai-nt.com\/?page_id=2653","url":"https:\/\/longmai-nt.com\/?page_id=2653","name":"\u97e6\u5973\u58eb\u5927\u5e73\u5c42 - \u9f99\u8109\u6696\u901a","isPartOf":{"@id":"https:\/\/longmai-nt.com\/#website"},"datePublished":"2026-06-09T04:59:37+00:00","dateModified":"2026-06-13T08:24:32+00:00","breadcrumb":{"@id":"https:\/\/longmai-nt.com\/?page_id=2653#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longmai-nt.com\/?page_id=2653"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longmai-nt.com\/?page_id=2653#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/longmai-nt.com\/"},{"@type":"ListItem","position":2,"name":"\u97e6\u5973\u58eb\u5927\u5e73\u5c42"}]},{"@type":"WebSite","@id":"https:\/\/longmai-nt.com\/#website","url":"https:\/\/longmai-nt.com\/","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","description":"\u4e13\u6ce8\u8212\u9002\u8282\u80fd\u8bbe\u8ba1","publisher":{"@id":"https:\/\/longmai-nt.com\/#organization"},"alternateName":"\u9f99\u8109\u6696\u901a","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longmai-nt.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/longmai-nt.com\/#organization","name":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8","alternateName":"\u9f99\u8109\u6696\u901a","url":"https:\/\/longmai-nt.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/","url":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","contentUrl":"https:\/\/longmai-nt.com\/wp-content\/uploads\/2026\/04\/logo.png","width":516,"height":478,"caption":"\u6210\u90fd\u5e02\u9f99\u8109\u6696\u901a\u8bbe\u5907\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/longmai-nt.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.xiaohongshu.com\/user\/profile\/5fe8a4e800000000010058d2"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2653"}],"version-history":[{"count":2,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2653\/revisions"}],"predecessor-version":[{"id":3153,"href":"https:\/\/longmai-nt.com\/index.php?rest_route=\/wp\/v2\/pages\/2653\/revisions\/3153"}],"wp:attachment":[{"href":"https:\/\/longmai-nt.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}